Professional Documents
Culture Documents
Product Description
Issue Date
02 2012-01-30
Notice
The purchased products, services and features are stipulated by the contract made between Huawei and the customer. All or part of the products, services and features described in this document may not be within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information, and recommendations in this document are provided "AS IS" without warranties, guarantees or representations of any kind, either express or implied. The information in this document is subject to change without notice. Every effort has been made in the preparation of this document to ensure accuracy of the contents, but all statements, information, and recommendations in this document do not constitute a warranty of any kind, express or implied.
Issue 02 (2012-01-30)
1 Product Positioning
Contents
1 Product Positioning ...................................................................................................................... 1 2 Product Introduction .................................................................................................................... 2
2.1 Frame ............................................................................................................................................................... 2 2.1.1 Double-sided Frame ................................................................................................................................ 2 2.1.2 Single-sided Frame ................................................................................................................................. 4 2.2 Bracket ............................................................................................................................................................. 5 2.3 Terminal Block ................................................................................................................................................. 6 2.4 Protective Unit ................................................................................................................................................. 8 2.5 Accessories ..................................................................................................................................................... 10 2.5.1 IDC Tool ............................................................................................................................................... 11 2.5.2 Testing Cord .......................................................................................................................................... 11 2.5.3 Disconnection Plug ............................................................................................................................... 12 2.5.4 Labels .................................................................................................................................................... 13 2.5.5 Base....................................................................................................................................................... 16
3 Application Scenarios ................................................................................................................ 18 4 Performance Indices ................................................................................................................... 20 5 Standard Compliance ................................................................................................................. 24 6 Acronyms and Abbreviations ................................................................................................... 25 A Product Detail List ..................................................................................................................... 26 B Product Packing Detail List ...................................................................................................... 28
Issue 02 (2012-01-30)
ii
1 Product Positioning
Figures
Figure 1-1 JPX01 products series .......................................................................................................................... 1 Figure 2-1 JPX-F3D double-sided frame .............................................................................................................. 3 Figure 2-2 JPX-SF3D single-sided frame ............................................................................................................. 4 Figure 2-3 JPX01 bracket ...................................................................................................................................... 5 Figure 2-4 JPX01 Terminal block.......................................................................................................................... 7 Figure 2-5 Dimensions of the JPX01 terminal block ............................................................................................ 8 Figure 2-6 JPX01 protective unit .......................................................................................................................... 8 Figure 2-7 Grounding bar ...................................................................................................................................... 9 Figure 2-8 Application schematic drawing of grounding bar ................................................................................ 9 Figure 2-9 Dimensions of the JPX01 protective unit .......................................................................................... 10 Figure 2-10 Dimensions of the protective unit grounding bar ............................................................................. 10 Figure 2-11 JPX01-DXD IDC tool ...................................................................................................................... 11 Figure 2-12 JPX01-TC testing cord .................................................................................................................... 12 Figure 2-13 JPX01 disconnection plug ............................................................................................................... 12 Figure 2-14 JPX01 MDF label ............................................................................................................................ 13 Figure 2-15 JPX01-ML-10 module label holder ................................................................................................. 13 Figure 2-16 Application schematic drawing of module label holder ................................................................... 14 Figure 2-17 JPX01 number flag .......................................................................................................................... 14 Figure 2-18 Application schematic drawing of number flag ............................................................................... 14 Figure 2-19 JPX01-NL-10 hinged label holder ................................................................................................... 15 Figure 2-20 Application schematic drawing of hinged label holder .................................................................... 16 Figure 2-21 JPX01 MDF base ............................................................................................................................. 16 Figure 3-1 Application used in the equipment room ........................................................................................... 18 Figure 3-2 Application used in the outdoor cabinet ............................................................................................. 19
Issue 02 (2012-01-30)
iii
1 Product Positioning
Tables
Table 2-1 Specifications of JPX-F3D double-sided frame .................................................................................... 3 Table 2-2 Specifications of JPX-SF3D single s-sided frame ................................................................................. 5 Table 2-3 Specifications of the JPX01 bracket ...................................................................................................... 6 Table 2-4 Specifications of the JPX01 terminal block ........................................................................................... 7 Table 2-5 Features of the JPX01 protective unit .................................................................................................... 9 Table 2-6 Specifications of the JPX01 protective unit ......................................................................................... 10 Table 2-7 Specifications of the JPX01-TC testing cord ....................................................................................... 12 Table 2-8 Specifications of JPX01 MDF base ..................................................................................................... 17 Table 4-1 The performance indices of JPX01 products ....................................................................................... 20 Table 4-2 Electric capability indexes of JPX01-SPD1-G400T ............................................................................ 22 Table 4-3 Electric capability indexes of JPX01-SPD1-G230F ............................................................................ 23
Issue 02 (2012-01-30)
iv
1 Product Positioning
Product Positioning
MDF (Main Distribution Frame) is the connection device between subscriber and exchange device. For ensure the signal is integrated, MDF products efficiently distribute, protect and management the network cables (copper cables). JPX01 product is among the Huaweis MDF product series. It implements the termination and connection of external cables and exchange cables, to create a cable termination environment for ADSL or VDSL service. JPX01 MDF supply the following accessorial equipment: protective unit, testing cord and disconnection plug, has the function of over-voltage and over-current protection, testing and controlling the lines connectivity. JPX01 MDF includes abundant types: double-sided frame and single-sided frame, meeting the scenario requirement of the inside environment; installed in the outdoor cabinet, meeting the scenario requirement of the outside environment. As shown in Figure 1-1. Figure 1-1 JPX01 products series
Double-sided frame
Single-sided frame
Outdoor cabinet
Issue 02 (2012-01-30)
2 Product Introduction
2
2.1 Frame
2.1.1 Double-sided Frame
Product Introduction
JPX01 consists of frame, bracket, terminal block, protective unit and accessories (including IDC tool, testing cord, disconnection plug, labels and base).
The frame supplies installation carrier for the bracket and terminal block. There are two models frame: double-sided frame and single-sided frame.
The cable side terminal blocks and exchange side terminal blocks are installed on the different sides of the double-sided frame. The cable side terminal block is vertically mounted on the front pillar and exchange side terminal block is horizontally mounted on the back beam. JPX01 double-sided frame has only one model available: JPX-F3D.
The product naming rules: JPX: Mandatory product SN of MDF distribution product
Issue 02 (2012-01-30)
2 Product Introduction
Features
Constructed of metal frame structure, easy to install and has good capability. Combined easily the left and right frames. Supports full front-operation for convenient maintenance. Enough space for layout of the cables, and the layout of the cables is orderly.
Specifications
Specifications of the JPX-F3D double-sided frame are shown in Table 2-1. Table 2-1 Specifications of JPX-F3D double-sided frame Model Dimensions (mm) HXWXD Cable tray height 200 External line Column Qty 2 Pair / column 100 X 7 Capacity (pair) 1400 Exchange line Row QTY 6 Pair / row 100 X 2 Capacity (pair) 1200
JPX-F3D
Issue 02 (2012-01-30)
2 Product Introduction
Appearance of JPX-SF3D single-sided frame is shown in Figure 2-2. Figure 2-2 JPX-SF3D single-sided frame
Features
Constructed of metal frame structure, easy to install and has good capability. Supports the installation near the wall for meeting the requirement of small equipment office. Flexible installation modes meet the different scenarios requirement: combined easily the left and right frames, back-to-back installation, installed in the corner. Supports full front-operation for convenient maintenance.
Issue 02 (2012-01-30)
2 Product Introduction
The cable trough box on the bottom of the frame facilitates the layout of the cable. The layout of the cable is advisable and clear. Enough space for layout of the cables, and the layout of the cables is orderly.
Specifications
Specifications of the JPX-SF3D single-sided frame are shown in Table 2-2. Table 2-2 Specifications of JPX-SF3D single s-sided frame Model Dimensions (mm) HXWXD Cable tray height External line Column Qty 1 Pair / column 100 X 7 Capacity (pair) 700 Exchange line Column QTY 1 Pair / column 70 X 10 Capacity (pair) 700
2.2 Bracket
The bracket is used for installing the terminal block and fixing it on the frame. JPX01 bracket has two models available: JPX01-BRK-11 and JPX01-BRK-8.
The product naming rules: JPX01: Product model SN for Huawei's MDF distribution product
Appearance of the JPX01 bracket is shown in Figure 2-3. Figure 2-3 JPX01 bracket
Issue 02 (2012-01-30)
2 Product Introduction
Features
The bracket for stainless steel is strong and durable. Each bracket has one grounding finger. To supply grounding protection, the grounding fingers belonged the same column are serial connection from beginning to end. The ground wire is led to the frame grounding bar from the ground terminal of the downmost bracket. JPX01-BRK-11 has 11 installation positions for blocks: the first one is used for installing the module label holder, the others is used for installing the terminal blocks. JPX01-BRK-8 has 8 installation positions for blocks: the first one is used for installing the module label holder, the others is used for installing the terminal blocks.
Specifications
Specifications of the JPX01 bracket are shown in Table 2-3. Table 2-3 Specifications of the JPX01 bracket Model JPX01-BRK-11 Dimensions H X W X D (mm) 248 X 104 X 50 Suitable for Frame JPX-F3D Suitable for Terminal Block Cable side terminal block Exchange side terminal block JPX-SF3D JPX01-BRK-8 150 X 104 X 50 JPX-SF3D Cable side terminal block Exchange side terminal block
BLK: Block 1: Product model SN for terminal block product 10: The capability is 10-pair K: The IDC contact is switching contact; B: the IDC contact is disconnection contact
Issue 02 (2012-01-30)
2 Product Introduction
Features
Capacity: 10-pair/block. Flexible IDC technology: 45o insulation displacement connection. Transmission performance meets the Category 5 standards. Compatible with the IDC tool for Krone type. Full-front operation. Before you insert wire in maintenance, you should remove the protective units of the adjacent ports. JPX01-BLK1-10K is switching contact. It is usually used for the cable side terminal block. JPX01-BLK1-10B is disconnection contact. It is usually used for the exchange side terminal block.
Specifications
Specifications of the JPX01 terminal block are shown in Table 2-4. Table 2-4 Specifications of the JPX01 terminal block Model JPX01-BLK1-10K JPX01-BLK1-10B Dimensions L X H X D (mm) 126.6 X 23.4 X 40.9
Issue 02 (2012-01-30)
2 Product Introduction
SPD: Surge protective device 1: Product model SN for protective unit product G: Gas discharge tube 400: DC breakdown voltage is 400V; 230: DC breakdown voltage is 230V T: Three point protection; F: Five point protection
Appearance of the JPX01 protective unit is shown in Figure 2-6. Figure 2-6 JPX01 protective unit
Features
Features of the JPX01 protective unit is shown in Table 2-5.
Issue 02 (2012-01-30)
2 Product Introduction
Table 2-5 Features of the JPX01 protective unit Model JPX01-SPD1G400T JPX01-SPD1G230F Over-voltage Protection Over-voltage component is the gas discharge tube:
Over-current Protection Without the over-current protection device Over-current component is high-speed and macromolecule PTCR (Positive Temperature Coefficient Resistor).
Protection Range Surge protection; Electrical power cable induction protection; Electrical power cable connection protection.
Strong ability for enduring current Many times for surge current impulsion
Matching with the grounding bar: each 10 pcs protective units matched with 1 pcs grounding bar. As shown in Figure 2-7 and Figure 2-8 . Figure 2-7 Grounding bar
2. Grounding bar
3. Protective unit
Specifications
Specifications of the JPX01 protective unit are shown in Table 2-6.
Issue 02 (2012-01-30)
2 Product Introduction
Table 2-6 Specifications of the JPX01 protective unit Model JPX01-SPD1-G400T JPX01-SPD1-G230F Grounding bar 109 X 11.7 X 23.7 Dimensions L X H X D (mm) 9.4 X 13.2 X 52
Dimensions of the JPX01 protective unit are shown in Figure 2-9. Figure 2-9 Dimensions of the JPX01 protective unit
Dimensions of the protective unit grounding bar are shown in Figure 2-10. Figure 2-10 Dimensions of the protective unit grounding bar
2.5 Accessories
JPX01 accessories cover IDC tool, testing cord, disconnection plug, labels and base.
Issue 02 (2012-01-30)
10
2 Product Introduction
Appearance of the JPX01-DXD is shown in Figure 2-11. Figure 2-11 JPX01-DXD IDC tool
Features
After the wire is terminated, the redundant wires are automatically cut off. Wire pulling-out hook and wire pressing-in fork equipped on the IDC tool can easily pull out and press in the wire.
Issue 02 (2012-01-30)
11
2 Product Introduction
Features
Remove the protective unit before you used the testing cord. Front-inserted. A pair of red clips is connected to the internal line tester or telephone set; A pair of black clips is connected to the external line tester (e.g. ohmmeter).
Specifications
Specifications of the JPX01 testing cord are shown in Table 2-7. Table 2-7 Specifications of the JPX01-TC testing cord Model JPX01-TC Dimensions Testing plug L X H X D (mm) Length for wire (m) 9.2 X 14.2 X 60.6 5
Features
Each 100-pair disconnection contact blocks (JPX01-BLK1-10B) match 5 pcs disconnection plug automatically. Front-inserted.
Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd 12
Issue 02 (2012-01-30)
2 Product Introduction
2.5.4 Labels
The labels are use for identifying the information such as line order of block. The JPX01 labels include MDF label, module label holder, number flag and hinged label holder.
MDF Label
The MDF label is used to identify the column of the cable side terminal block. Appearance of the JPX01 MDF label is shown in Figure 2-14. Figure 2-14 JPX01 MDF label
Each frame matches 1 pcs MDF label automatically. It is white words on blue background and self-adhesive. It can be directly stuck to the corresponding groove of the identification board on top of the distribution frame.
Appearance of the JPX01 module label holder is shown in Figure 2-15. Figure 2-15 JPX01-ML-10 module label holder
Issue 02 (2012-01-30)
13
2 Product Introduction
JPX01-ML-10 is installed in the first installation position to identify the block information of the total bracket.
The application of JPX01-ML-10 is shown in Figure 2-16. Figure 2-16 Application schematic drawing of module label holder
Number Flag
The number flag is used to identify the series number of each terminal block. Appearance of the JPX01 number flag is shown in Figure 2-17. Figure 2-17 JPX01 number flag
Each 100-pair terminal blocks match 1 pcs number flag automatically. JPX01 number flag is installed in the one side of terminal block to identify the series number.
The application of JPX01 number flag is shown in Figure 2-18. Figure 2-18 Application schematic drawing of number flag
Issue 02 (2012-01-30)
14
2 Product Introduction
Appearance of the JPX01 hinged label holder is shown in Figure 2-19. Figure 2-19 JPX01-NL-10 hinged label holder
The number flag and the hinged label holder are both used to identify the series number of each terminal block. But they are suitable for different condition.
The number flag could be used whether the block installed the protective unit. The hinged label holder is only used for the block without protective unit. They will not be used at one time.
Each terminal block matches 1 pcs hinged label holder. JPX01-NL-10 is installed in front of the terminal block to identify the terminal block information.
Issue 02 (2012-01-30)
15
2 Product Introduction
2.5.5 Base
The base is optional parts. It is the support parts of ground-mount MDF. According the different subscriber requirement, we could change the height of MDF through adjusting the base height. JPX01 MDF base and JPX202 base is common. They have four models available: JPX202-FD-DZA, JPX202-FD-DZB, JPX202-SFD-DZA, JPX202-SFD-DZB.
The product naming rules: JPX202: Product model SN for Huawei's MDF distribution product
FD: 2-column frame; SFD: 2-column single frame DZ: Code name for Huawei's base product A, B: Product model SN for base product
Appearance of the JPX01 MDF base is shown in Figure 2-21. Figure 2-21 JPX01 MDF base
Features
The steel frame body is high intensity and anticorrosion. Installation and operation is simple and easy. The height is adjustable for convenient use.
Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd 16
Issue 02 (2012-01-30)
2 Product Introduction
Specifications
Specifications of the JPX01 MDF base are shown in Table 2-8. Table 2-8 Specifications of JPX01 MDF base Model Dimensions H X W X D(mm) Pitch JPX202-FD-DZA 10 Adjusting range for H 180-320 (Without gasket) 185-325 (With gasket) JPX202-FD-DZB 10 330-610 (Without gasket) 335-615 (With gasket) JPX202-SFD-DZA 10 180-320 (Without gasket) 185-325 (With gasket) JPX202-SFD-DZB 10 330-610 (Without gasket) 335-615 (With gasket) 500 X 590 JPX-SF3D single-sided frame WXD 500 X 790 JPX-F3D double-sided frame Suitable for Frame
Issue 02 (2012-01-30)
17
3 Application Scenarios
Application Scenarios
JPX01 provides cable termination environment for the connection between the external cables and switching equipment. It cooperates with Huaweis MA5600T to provide xDSL service. JPX01 can be used both in the equipment room (including the central office, remote office and residential equipment room), and in the outdoor cabinet. It can be deployed in the new or expansion project. The application of JPX01 products is shown in Figure 3-1 and Figure 3-2. Figure 3-1 Application used in the equipment room
Issue 02 (2012-01-30)
18
3 Application Scenarios
Issue 02 (2012-01-30)
19
4 Performance Indices
4
Table 4-1 The performance indices of JPX01 products Performance Indices Parameter Value Operating Condition Application class Operating temperature Storage temperature Relative humidity Atmospheric pressure Material Flammability Environment protection Plastic parts Protective unit Class V-0 Meet RoHS requirement PC-FR Grounding bar Over-voltage component Over-current component Cu H62-Y2 GDT PTCR Class 3.3 -25 to +65 -40 to +70 8 to 100 70-106 kPa
Performance Indices
Standard Compliance
Issue 02 (2012-01-30)
20
4 Performance Indices
Parameter Value ID termination material Surface finishes Tin-phosphor bronze QSn6.5 Nickel-plate, local Gild (Au) RAL9010 (ID bracket) RAL7035 (Pedestal) Protective unit Testing cord RAL 7035 RAL 7035
Color
Block
---
Mechanical Capability Block Solid wire diameter range Number of wire terminations Number of plugging Transverse extraction force Longitudinal extraction force Endurance 0.4-0.65 mm (Insulation diameter 1.4 mm) 100 750 50 N @ 0.5 mm 10 N @ 0.5 mm Repeated insertion/withdrawals: 200 cycles from fully inserted to intermediate position. Maximum change in protector/block contact resistance is less than 3 m. Environmental Adaptability Temperature variation High temperature environment Temperature / humidity cycles Vibration 100 cycles 1 h @ -40 / +70 500 h @ +70 IEC 11801 IEC 11801 -IEC 11801 IEC 11801 --YD/T 694-2004
IEC 11801
IEC 11801
Issue 02 (2012-01-30)
21
4 Performance Indices
Performance Indices
Parameter Value
Standard Compliance
Electric Capability Block Resistance of disconnection contact IDC contact resistance Insulation resistance Dielectric strength Protective unit 7 m YD/T694-2004
Electric capabilities for the two models protective unit are very different. The detailed indexes are shown in Table 4-2 and Table 4-3.
Table 4-2 Electric capability indexes of JPX01-SPD1-G400T Electric Capability DC breakdown voltage Insulation resistance Capacity (line to earth) Impulse breakdown voltage Parameter Value 350-500 V @ 100 V/s 1000 M @ 100 V DC 20 pF @ 1 MHz, 0.5 V 800 V @ 100V/s 950 V @ 1 kV/s AC surge AC discharge Impulse discharge current 600 V AC, 1s, 5 times @ 1 min intervals, 50 Hz 10 times @ 5 A applications each line side, 3 min intervals, 50 Hz 300 times (alternating polarity) @ 100 A, 10/1000 s 5 times of each polarity @ 2 kA (total current through center electrode), 8/20 s Failure action time 15s @ 2A (1 A 2), 600 VAC, 50 Hz -ITU/T Rec. K.20 ITU/T Rec. K.12 YD/T 694-2004 Standard Compliance ITU/T Rec. K.12 YD/T 694-2004 -ITU/T Rec. K.12
Issue 02 (2012-01-30)
22
4 Performance Indices
Table 4-3 Electric capability indexes of JPX01-SPD1-G230F Electric Capability DC breakdown voltage Insulation resistance Capacity (line to earth) Impulse breakdown voltage Parameter Value 200 - 300 V @ 100 V/s 1000 M @ 100 V DC 20 pF @ 1 MHz, 0.5 V 600 V @ 100 V/s 700 V @ 1 kV/s PTCR room-temperature resistance Hold current Over-current operating characteristic 22 120 mA @ +40, 1 h 40s @ 0.35-0.1 A, 25 15s @ 0.5-0.1 A, 25 < 2s @ 1-0.1 A, 25 0.3s @ 3-0.1 A, 25 AC surge AC discharge Impulse discharge current 600 VAC, 1s, 5 times @ 1 min intervals, 50 Hz 10 times @ 5 A applications each line side, 3 min intervals, 50 Hz 300 times (alternating polarity) @ 100 A, 10/1000 s 5 times of each polarity @ 2 kA (total current through center electrode), 8/20 s Failure action time 15s @ 2A (1 A 2), 600 V AC, 50 Hz -ITU/T Rec. K.20 ITU/T Rec. K.12 YD/T 694-2004 YD/T 694-2004 YD/T 694-2004 YD/T 694-2004 Standard Compliance ITU/T Rec. K.12 YD/T 694-2004 -ITU/T Rec. K.12
Issue 02 (2012-01-30)
23
5 Standard Compliance
5
International Standard ETS 300019-1-3 UL94 V-0 IEC 11801 ITU-T K.11 ITU-T K.12 ITU-T K.20 ITU/T Rec. K.30 ITU/T K.44 ITU/T K.45 IEC 60189-3 IEC 60068
Standard Compliance
Environmental conditions and environmental tests for telecommunications equipment - Part 1-3: Classification of environmental conditions; stationary use at weatherprotected locations Test for Flammability of Plastic Materials for Parts in Devices and Appliances Information technology - Generic cabling for customer premises Principles of protection against overvoltages and overcurrents Characteristics of gas discharge tubes for the protection of telecommunications installations Resistibility of telecommunication equipment installed in a telecommunications centre to overvoltages and overcurrents Positive temperature coefficient (PTC) thermistors Resistibility tests for telecommunication equipment exposed to overvoltages and overcurrents - Basic Recommendation Resistibility of access network equipment to overvoltages and overcurrents Low-frequency cables and wires with P.V.C. insulation and P.V.C. sheath. Part 3: Equipment wires with solid or stranded conductor, PVC insulated, in singles, pairs and triples Environmental Testing
National Standard YD/T 694-2004 Main Distribution Frame and Rules for Enforcement on Quality Authentication and Inspection of MDF Homologation
Issue 02 (2012-01-30)
24
6
AC ADSL DC GDT IDC MDF PC PTCR VDSL
Abbreviation in English
Issue 02 (2012-01-30)
25
A
Name Double-sided frame Single-sided frame Bracket Model JPX-F3D JPX-SF3D JPX01-BRK-11 Remark
External line capacity: 1400; Exchange line capacity: 1200 External line capacity: 700; Exchange line capacity: 700 11 installation position: one is used for the module label holder, ten are used for the terminal blocks Used for installing the exchange side and cable side terminal block on the JPX-F3D, or installing the cable side terminal block on the JPX-SF3D
JPX01-BRK-8
8 installation position: one is used for the module label holder, seven are used for the terminal blocks Used for installing the exchange side terminal block on the JPXSF3D
Terminal block
JPX01-BLK1-10K
JPX01-BLK1-10B
Protective unit
JPX01-SPD1-G400T JPX01-SPD1-G230F
Gas discharge tube; Supply over-voltage protection; Supply VDSL2 service Gas discharge tube; Supply over-voltage and over-current protection; Supply ADSL service Each 100-pair disconnection contact blocks (JPX01-BLK1-10B) match 5 pcs disconnection plug automatically Each frame matches 1 pcs MDF label automatically
JPX01-DXD JPX01-TC -
Issue 02 (2012-01-30)
26
Name Module label holder Number flag Hinged label holder MDF Base
Remark Each bracket matches 1 pcs module label holder Each 100-pair terminal blocks match 1 pcs number flag automatically Each terminal block matches 1 pcs hinged label holder H adjustable range: 180-325 mm H adjustable range: 330-615mm H adjustable range: 180-325 mm H adjustable range: 330-615 mm Suitable for JPX-SF3D frame Suitable for JPX-F3D frame
Issue 02 (2012-01-30)
27
B
Model Net Weight (kg) JPX202-F3D JPX202-SF3D JPX01-BRK-11 JPX01-BRK-8 JPX01-BLK1-10K JPX01-BLK1-10B JPX01-SPD1-G400T JPX01-SPD1-G230F 4.2 g 66 57 356 g 276 g 55 g (pcs) 1/box 1/box 20/box 20/box 240/box
Packing Qty.
Remark
(20/carton X 12 cartons) 1200/box (40/carton X 30 cartons. Each carton has 4 grounding strips in it.) 120/box (1/packge X 120 packges) 1/box 1/box 1/box 1/box
Issue 02 (2012-01-30)
28