You are on page 1of 5

KLM - KLP / DKLM- DKLP

HEATING , AIR CONDITIONING SYSTEMS, SOLAR PANEL


AND HOT WATER SYSTEMS

ENERGY
EFFICIENCY

Pump body and motor support in cast iron.


PN10 flanged connections with threaded holes for control
pressure gauges.Technopolymer impeller and carbon/
ceramic mechanical seal.
Four-pole, asynchronous motor for the KLM and DKLM
versions and two-pole for the KLP and DKLP versions.
Built-in thermal and current overload protection and a
capacitor permanently on in the single-phase version.
Three-phase motors should be protected with a suitable
overload protection complying with the regulations in
force. In the twin version there is a built-in automatic
clapet valve on the delivery vent; the standard supply
also includes a blank flange.

Operating range: from 2 to 67 m3/h with head up to


13.7 metres.
Liquid temperature range: from -15C to +120C.
Pumped liquid characteristics: clean , free from solids
or abrasive substances , not viscous, not aggressive, not
crystallised, chemically neutral.
Maximum ambient temperature: +40C.
Maximum working pressure: 10 bar (1000 kPa).
Protection level: IP 55.
Insulation class: F.
Standard flanging: PN 10/PN 6.
Counter flanges either threaded or with welded
collar as requested.

TECHNICAL DATA - KLM/KLP single flanged


MODEL

CODE

ELECTRICAL DATA
P2 NOMINAL
kW

KLM - 1400 r.p.m. 1/min - 4 poles


KLP - 2800 r.p.m. 1/min - 2 poles
CENTRE
DISTANCE
mm

PUMP
COUPLINGS

HP

In
A

KLM 40-300 M

105110404

1 x 230 V ~

0,25

0,33

0,9

250

DN 40

KLM 40-300 T

105110014

3 x 230 - 400 V ~

0,25

0,33

0,9-0,55

250

DN 40

KLP 40-600 M

105110414

1 x 230 V ~

0,37

0,5

250

DN 40

KLP 40-600 T

105110214

3 x 230 - 400 V ~

0,37

0,5

1,7-1

250

DN 40

KLP 40-900 M

105110424

1 x 230 V ~

0,37

0,5

3,2

250

DN 40

KLP 40-900 T

105110224

3 x 230 - 400 V ~

0,37

0,5

1,9-1,1

250

DN 40

KLP 40-1200 M

105110434

1 x 230 V ~

0,55

0,75

3,4

250

DN 40

KLP 40-1200 T

105110234

3 x 230 - 400 V ~

0,55

0,75

2-1,2

250

DN 40

KLM 50-300 M

105110444

1 x 230 V ~

0,25

0,33

0,9

280

DN 50

KLM 50-300 T

105110054

3 x 230 - 400 V ~

0,25

0,33

1-0,6

280

DN 50

KLM 50-600 M

105110454

1 x 230 V ~

0,25

0,33

1,4

280

DN 50

KLM 50-600 T

105110074

3 x 230 - 400 V ~

0,25

0,33

1,2-0,7

280

DN 50

KLP 50-900 M

105110464

1 x 230 V ~

0,75

3,3

280

DN 50

KLP 50-900 T*

60145205

3 x 230 - 400 V ~

0,75

2,8/1,6

280

DN 50

KLP 50-1200 M

105110474

1 x 230 V ~

0,75

4,2

280

DN 50

KLP 50-1200 T*

60145206

3 x 230 - 400 V ~

0,75

3,2/1,8

280

DN 50

KLM 65-300 T

105110094

3 x 230 - 400 V ~

0,25

0,33

1/0,6

340

DN 65

KLM 65-600 T

105110114

3 x 230 - 400 V ~

0,37

0,5

1,2/0,7

340

DN 65

KLP 65-900 T*

60145819

3 x 230 - 400 V ~

1,1

1,5

4/2,35

340

DN 65

KLP 65-1200 T*

60145820

3 x 230 - 400 V ~

1,1

1,5

4,7/2,7

340

DN 65

KLM 80-300 T

105110134

3 x 230 - 400 V ~

0,25

0,33

1,2/0,7

360

DN 80

KLM 80-600 T*

60146973

3 x 230 - 400 V ~

0,75

2,8/1,6

360

DN 80

KLP 80-900 T*

60145915

3 x 230 - 400 V ~

1,84

2,5

5,2/3

360

DN 80

KLP 80-1200 T*

60145917

3 x 230 - 400 V ~

1,84

2,5

6,6/3,8

360

DN 80

* NEW IE2 MOTOR


DAB PUMPS reserves the right to make modifications without notice

VOLTAGE 50 Hz

CIRCULATORS AND IN-LINE PUMPS

IN-LINE PUMPS

KLM - KLP / DKLM- DKLP

CIRCULATORS AND IN-LINE PUMPS

IN-LINE PUMPS

TECHNICAL DATA - DKLM/DKLP TWIN flanged

DKLM - 1400 r.p.m. 1/min - 4 poles


DKLP - 2800 r.p.m. 1/min - 2 poles
ELECTRICAL DATA

MODEL

CODE

VOLTAGE 50 Hz

P2 NOMINAL
kW

HP

In
A

CENTRE
DISTANCE
mm

PUMP
COUPLINGS

DKLM 40-300 M

105210404

1 x 230 V ~

0,25

0,33

0,9

250

DN 40

DKLM 40-300 T

105210014

3 x 230 - 400 V ~

0,25

0,33

0,9-0,55

250

DN 40

DKLP 40-600 M

105210414

1 x 230 V ~

0,37

0,5

250

DN 40

DKLP 40-600 T

105210214

3 x 230 - 400 V ~

0,37

0,5

1,7-1

250

DN 40

DKLP 40-900 M

105210424

1 x 230 V ~

0,37

0,5

3,2

250

DN 40

DKLP 40-900 T

105210224

3 x 230 - 400 V ~

0,37

0,5

1,9-1,1

250

DN 40

DKLP 40-1200 M

105210434

1 x 230 V ~

0,55

0,75

3,4

250

DN 40

DKLP 40-1200 T

105210234

3 x 230 - 400 V ~

0,55

0,75

2-1,2

250

DN 40

DKLM 50-300 M

105210444

1 x 230 V ~

0,25

0,33

0,9

280

DN 50

DKLM 50-300 T

105210054

3 x 230 - 400 V ~

0,25

0,33

1-0,6

280

DN 50

DKLM 50-600 M

105210454

1 x 230 V ~

0,25

0,33

1,4

280

DN 50

DKLM 50-600 T

105210074

3 x 230 - 400 V ~

0,25

0,33

1,2-0,7

280

DN 50

DKLP 50-900 M

105210464

1 x 230 V ~

0,75

3,3

280

DN 50

DKLP 50-900 T*

60145209

3 x 230 - 400 V ~

0,75

2,8/1,6

280

DN 50

DKLP 50-1200 M

105210474

1 x 230 V ~

0,75

4,2

280

DN 50

DKLP 50-1200 T*

60145210

3 x 230 - 400 V ~

0,75

3,2/1,8

280

DN 50

DKLM 65-300 T

105210094

3 x 230 - 400 V ~

0,25

0,33

1/0,6

340

DN 65

DKLM 65-600 T

105210114

3 x 230 - 400 V ~

0,37

0,5

1,2/0,7

340

DN 65

DKLP 65-900 T*

60145826

3 x 230 - 400 V ~

1,1

1,5

4/2,35

340

DN 65

DKLP 65-1200 T*

60145827

3 x 230 - 400 V ~

1,1

1,5

4,7/2,7

340

DN 65

DKLM 80-300 T

105210134

3 x 230 - 400 V ~

0,25

0,33

1,2/0,7

360

DN 80

DKLM 80-600 T*

60146983

3 x 230 - 400 V ~

0,75

2,8/1,6

360

DN 80

DKLP 80-900 T*

60145933

3 x 230 - 400 V ~

1,84

2,5

5,2/3

360

DN 80

DKLP 80-1200 T*

60145935

3 x 230 - 400 V ~

1,84

2,5

6,6/3,8

360

DN 80

* NEW IE2 MOTOR


DAB PUMPS reserves the right to make modifications without notice

Blank counterflange supplied as standard for twin version

KLM - KLP / DKLM- DKLP


KLM - KLP 40

DKLM - DKLP 40

10

20

10

30
20

40

50

30

40

60

70

50

80

60

90
70

100
80

110

120

Q US gpm

90

100

Q IMP gpm

H
m

P
kPa
120

H
ft
40

12

DKLP 40/1200
35
100

10

DKLP 40/900
80

30

60

40

20

25

DKLP 40/600

20

DKLP 40/1200 1+2 15

10

DKLM 40/300
0

NPSH
m
8
6
4
2
0

DKLP 40/600 1+2

DKLM 40/300 1+2


12
16

20

DKLP 40/900 1+2

24

0
Q m3/h
NPSH
ft

28

DKLP 40/1200

20

DKLP 40/900
DKLM 40/300
4

10

DKLP 40/600
8

12

16

20

24

28

20

24

28

0
Q m /h
3

%
DKLP 40/900

DKLM 40/300

50

DKLP 40/1200

40
30

KLM - KLP 50

0
0
P
kPa
120

16

W
400
300
200
100
0

32

16

48
32

64

80

48

64

112

80

128

144

112

80 Q
128

H
m

m
H

40

12

KLP 50/1200
100

DKLM - DKLP 50

120

100

10

Q m3/h
HP
0,6

DKLP 40/1200
DKLP 40/900

0,4

DKLP 40/600

0,2

DKLM 40/300
0
0
0

P
kPa

DKLP 40/600
12
16

0
0

4
1
20
50
20

12

2
40
100

40

16

3
60
150

60

20

4
100
250
80

80
200

5
120
300
100

6
140
350
120

0
Q m3/h
7
8
Q l/s
160
180
200 Q US gpm
400
450
500 Q l/min
Q IMP gpm
140
160
24

28

H
m

H
ft
40

12

35

DKLP 50/1200

10

30

30
80

60

40

80

KLP 50/900

20

KLM 50/600

25

DKLP 50/900
60

20

6
DKLP 50/1200 1+2

15
40

20

DKLM 50/600

10

10
20

0
P H
m
4
3
2
1
0

KLM 50/300

DKLM 50/300

12

16

20

24

12

36

0
Q m3/h
P H
10

KLP 50/900

KLM 50/300

16

32

KLP 50/1200

KLM 50/600

28

20

24

28

32

36

0
Q m3/h

0 KLM 50/300

60

0
40

KLP 50/1200
KLM 50/600

DAB PUMPS0 reserves4 the right


without
notice
8 to make
12 modifications
16
20
24
600
400

KLP 50/900
28

16

36

Q m3/h

KLP 50/1200
KLP 50/900

HP
0 8
0 6
0 4

NPSH
m
4
3
2
1
0
%
50
40
30
20
10
0

10

DKLP 50/900 1+2


DKLM 50/600 1+2
DKLM 50/300 1+2
15

20

25

30

200

40

45

DKLP 50/1200

0
Q m3/h
NPSH
ft
10

DKLP 50/900

5
DKLM 50/300
0

10

15

20

25

30

35

40

45

0
Q m /h

35

40

45

Q m3/h

DKLP 50/1200
DKLP 50/900
DKLM 50/600

DKLM 50/300
0

10

15

20

25

W
600
400

35

30

DKLP 50/1200
DKLP 50/900
DKLM 50/600

HP
0,8
0,6
0,4
0,2

CIRCULATORS AND IN-LINE PUMPS

IN-LINE PUMPS

KLM - KLP / DKLM- DKLP

CIRCULATORS AND IN-LINE PUMPS

IN-LINE PUMPS

KLM - KLP 65

DKLM - DKLP 65

40

0
P
kPa
120

100

80

40

120
80

160

200

120

240

160

280

200

320 Q US gpm

240

Q IMP gpm

H
m

H
ft
40

12

35

DKLP 65/1200
10

30
80

25

DKLP 65/900
60

40

DKLP 65/1200 1+2

20

15

DKLM 65/600
20

10

2
DKLP 65/900 1+2

DKLM 65/300
0

NPSH
m
4
3
2
1
0

10

DKLM 65/600 1+2


DKLM 65/300 1+2
30
40
50
60

20

70

DKLP 65/1200
DKLP 65/900
DKLM 65/600

DKLM 65/300
20
30

10

40

0
Q m3/h
NPSH
ft
12
8
4

50

60

70

0
Q m /h

60

70

Q m3/h

%
50
40
30
20

KLM - KLP 80

DKLM 65/300
0

20

30

DKLP 65/1200

40

50

HP
DKLP 65/1200

1,2

DKLP 65/900

0,8

DKLM 65/600
DKLM 65/300
0
0
0

DAB PUMPS reserves the right to make modifications without notice

10

DKLM - DKLP 80
kW
1
0,8
0,6
0,4
0,2
0

DKLM 65/600
DKLP 65/900

10
2

4
200

20
6

30
8
400

0,4

40
10
600

12

50
14
800

60
16
1000

18

70
20
1200

0
Q /h
Q l/s
m3

Q l/min

KLM - KLP / DKLM- DKLP


IN-LINE PUMPS

KLM - KLP

MODEL

KLM 40/300
KLP 40/600
KLP 40/900
KLP 40/1200
KLM 50/300
KLM 50/600
KLP 50/900
KLP 50/1200
KLM 65/300
KLM 65/600
KLP 65/900
KLP 65/1200
KLM 80/300
KLM 80/600
KLP 80/900
KLP 80/1200

B1

B2

DNA

DNM

D1

D2

D3

110
110
110
110
110
110
110
110
110
110
110
110
110
110
110
110

179
179
179
179
204
204
204
204
228
228
228
228
229
229
229
229

82
82
82
82
94
94
94
94
99
99
99
99
99
99
99
99

97
97
97
97
110
110
110
110
129
129
129
129
130
130
130
130

100
100
100
100
100
100
100
100
100
100
100
100
115
115
115
115

40
40
40
40
50
50
50
50
65
65
65
65
80
80
80
80

40
40
40
40
50
50
50
50
65
65
65
65
80
80
80
80

80
80
80
80
90
90
90
90
110
110
110
110
128
128
128
128

100
100
100
100
110
110
110
110
130
130
130
130
150
150
150
150

110
110
110
110
125
125
125
125
145
145
145
145
160
160
160
160

150
150
150
150
165
165
165
165
185
185
185
185
200
200
200
200

D4

395
4
395
SLOTS
18x23 395
395
414
4
414
SLOTS
18x25,5 414
414
433
4
433
SLOTS
18x25,5 433
433
453
4
453
SLOTS
18x23 453
453

H1

L1

L2

66
66
66
66
73
73
73
73
82
82
82
82
97
97
97
97

250
250
250
250
280
280
280
280
340
340
340
340
360
360
360
360

125
125
125
125
140
140
140
140
170
170
170
170
190
190
190
190

125
125
125
125
170
170
170
170
170
170
170
170
170
170
170
170

M
2
HOLES
10
2
HOLES
10
2
HOLES
12
2
HOLES
12

PACKAGING DIMESIONS WEIGHT Q.TY


X
KG
PALLET
L/A
L/B
H
470
280
330
21,1
12
470
280
330
22,5
12
470
280
330
22,5
12
470
280
330
23,2
12
470
280
330
24,6
12
470
280
330
24,6
12
470
280
330
26,2
12
470
280
330
26,3
12
510
310
470
29,3
8
510
310
470
29,5
8
510
310
470
35
8
510
310
470
35
8
510
310
470
32,5
8
510
310
470
36,7
8
510
310
470
39,6
8
510
310
470
40
8

DKLM - DKLP

MODEL

DKLM 40/300
DKLP 40/600
DKLP 40/900
DKLP 40/1200
DKLM 50/300
DKLM 50/600
DKLP 50/900
DKLP 50/1200
DKLM 65/300
DKLM 65/600
DKLP 65/900
DKLP 65/1200
DKLM 80/300
DKLM 80/600
DKLP 80/900
DKLP 80/1200

B1

B2

DNA

DNM

D1

D2

D3

110
110
110
110
110
110
110
110
110
110
110
110
110
110
110
110

372
372
372
372
434
434
434
434
455
455
455
455
463
463
463
463

185
185
185
185
217
217
217
217
226
226
226
226
230
230
230
230

187
187
187
187
217
217
217
217
229
229
229
229
233
233
233
233

100
100
100
100
120
120
120
120
140
140
140
140
150
150
150
150

40
40
40
40
50
50
50
50
65
65
65
65
80
80
80
80

40
40
40
40
50
50
50
50
65
65
65
65
80
80
80
80

80
80
80
80
90
90
90
90
110
110
110
110
128
128
128
128

100
100
100
100
110
110
110
110
130
130
130
130
150
150
150
150

110
110
110
110
125
125
125
125
145
145
145
145
150
150
150
150

150
150
150
150
165
165
165
165
185
185
185
185
200
200
200
200

DAB PUMPS reserves the right to make modifications without notice

D4

400
4
400
slots
18x23 400
400
410
4
410
slots
18x25,5 410
410
430
4
430
slots
18x25,5 430
430
445
4
445
slots 445
18x23
445

H1

L1

L2

55
55
55
55
73
73
73
73
82
82
82
82
97
97
97
97

200
200
200
200
240
240
240
240
240
240
240
240
240
240
240
240

250
250
250
250
280
280
280
280
340
340
340
340
360
360
360
360

125
125
125
125
140
140
140
140
170
170
170
170
190
190
190
190

125
125
125
125
140
140
140
140
170
170
170
170
170
170
170
170

M
4
holes
10
4
holes
14
4
holes
14
4
holes
14

PACKAGING DIMESIONS WEIGHT Q.TY


X
KG
PALLET
L/A L/B
H
530 280 470 38,2
8
530 280 470 41,8
8
530 280 470 41,8
8
530 280 470 41,8
8
540 420 610
51
2
540 420 610
52
2
540 420 610
54
2
540 420 610
54
2
540 420 610
55
2
540 420 610
62
2
540 420 610
66
2
540 420 610
66
2
540 420 610
62
2
540 420 610
70
2
540 420 610
76
2
540 420 610
76
2

CIRCULATORS AND IN-LINE PUMPS

DIMENSIONS AND WEIGHTS

You might also like