Professional Documents
Culture Documents
27.02.2014
Due to missing symmetry properties, no UGR table can be displayed for this luminaire.
Page 1
Project 1
27.02.2014
Luminaire: Luminous flux (Luminaire): Luminous flux (Lamps): Luminaire Wattage: Arrangement: Pole Distance: Mounting Height (1): Height: Overhang (2): Boom Angle (3): Boom Length (4):
Philips SGP398 GB 1xSON-T250W SGR 22680 lm Maximum luminous intensities 28000 lm at 70: 364 cd/klm 276.0 W at 80: 90 cd/klm Single row, bottom at 90: 0.00 cd/klm Any direction forming the specified angle from the downward vertical, with the 25.000 m luminaire installed for use. 10.000 m No luminous intensities above 90. 10.225 m Arrangement complies with luminous intensity class G4. 2.500 m Arrangement complies with glare index class D.6. 0.0 3.000 m
Page 2
Project 1
27.02.2014
Page 3
Project 1
27.02.2014
Maintenance factor: 0.57 Calculation Field List 1 Valuation Field Roadway 1 Length: 25.000 m, Width: 10.000 m Grid: 10 x 7 Points Accompanying Street Elements: Roadway 1. Selected Lighting Class: S6 Additional ES Lighting Class: ES9 Calculated values: Required values according to class: Fulfilled/Not fulfilled:
1
Scale 1:222
(Not all lighting performance requirements are met.) (Not all lighting performance requirements are met.) Eav [lx] 29.94 2.00
1
Notice: To provide for uniformity, the actual value of the maintained average illuminance may not exceed 1.5 times the minimum value indicated for the class.
Page 4
Project 1
27.02.2014
Valuation Field Sidewalk 2 Length: 25.000 m, Width: 4.000 m Grid: 10 x 3 Points Accompanying Street Elements: Sidewalk 2. Selected Lighting Class: CE5 (All lighting performance requirements are met.) Calculated values: Required values according to class: Fulfilled/Not fulfilled: Eav [lx] 13.54 7.50 U0 0.66 0.40
Page 5
Project 1
27.02.2014
Page 6
Project 1
27.02.2014
Maintenance factor: 0.57 Grid: 10 x 7 Points Accompanying Street Elements: Roadway 1. Selected Lighting Class: S6 Additional ES Lighting Class: ES9 Calculated values: Required values according to class: Fulfilled/Not fulfilled:
1
Scale 1:222
(Not all lighting performance requirements are met.) (Not all lighting performance requirements are met.) Eav [lx] 29.94 2.00
1
Notice: To provide for uniformity, the actual value of the maintained average illuminance may not exceed 1.5 times the minimum value indicated for the class.
Page 7
Project 1
27.02.2014
Page 8
Project 1
27.02.2014
Values in Lux, Scale 1 : 222 Grid: 10 x 7 Points Eav [lx] 30 Emin [lx] 16 Emax [lx] 47 u0 0.530 Emin / Emax 0.337
Page 9
Project 1
27.02.2014
Scale 1 : 222 Grid: 10 x 7 Points Eav [lx] 30 Emin [lx] 16 Emax [lx] 47 u0 0.530 Emin / Emax 0.337
Page 10
Project 1
27.02.2014
Values in Lux, Scale 1 : 222 Grid: 10 x 7 Points Eav [lx] 30 Emin [lx] 16 Emax [lx] 47 u0 0.530 Emin / Emax 0.337
Page 11
Project 1
27.02.2014
Values in Lux, Scale 1 : 222 Grid: 10 x 3 Points Eav [lx] 12 Emin [lx] 6.93 Emax [lx] 22 u0 0.571 Emin / Emax 0.320
Page 12
Project 1
27.02.2014
Scale 1 : 222 Grid: 10 x 3 Points Eav [lx] 12 Emin [lx] 6.93 Emax [lx] 22 u0 0.571 Emin / Emax 0.320
Page 13
Project 1
27.02.2014
Values in Lux, Scale 1 : 222 Grid: 10 x 3 Points Eav [lx] 12 Emin [lx] 6.93 Emax [lx] 22 u0 0.571 Emin / Emax 0.320
Page 14
Project 1
27.02.2014
Values in Lux, Scale 1 : 222 Grid: 10 x 3 Points Eav [lx] 14 Emin [lx] 8.97 Emax [lx] 21 u0 0.663 Emin / Emax 0.430
Page 15
Project 1
27.02.2014
Scale 1 : 222 Grid: 10 x 3 Points Eav [lx] 14 Emin [lx] 8.97 Emax [lx] 21 u0 0.663 Emin / Emax 0.430
Page 16
Project 1
27.02.2014
Values in Lux, Scale 1 : 222 Grid: 10 x 3 Points Eav [lx] 14 Emin [lx] 8.97 Emax [lx] 21 u0 0.663 Emin / Emax 0.430
Page 17