Read prior to operation Adhere to safety instructions Keep for future use.
This device is not intended to be used by persons (including children) with limited physical, sensory or mental aptitude or lack of experience and/or knowledge unless they are supervised by a person responsible for their safety or have received instruction from this person as to how the device is used
FUNK GmbH Klte mit System, Zunftstrasse 8, D-77694 Kehl Fon: 07854 / 7077-78 Fax: 07854 / 7566 E-Mail: info@funk-gmbh.de
Operating Instructions
type F/FV/FRV
Contents
1 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 2 2.1 2.2 2.3 2.4 3 3.1 3.2 4 4.1 4.2 4.3 4.3.1 4.3.2 5 5.1 5.1.1 5.1.2 5.1.3 5.1.4 5.1.5 5.2 5.3 6 7 8 9 10 11 12 Safety dangers/hazards symbols used correct use/operation sources of danger operator/ skilled person actions to be taken on job-site safety devices noise emission/hearing protection Transport/ Installation/ Storage transport/ storage set-up/ installation/ connection initial operation functional principle Operation/ Use construction/ controls operation/ use Troubleshooting general fault repair refrigerant injection valve automatic refrigerant injection valve thermostatic refrigerant injection valve Cleaning /Maintenance/ Taking out of operation cleaning and care cleaning of water basin cleaning of evaporator drum, ice scraper and ice chute cleaning of strainers cleaning of condenser cleaning schedule maintenance disposal Exploded drawing Type FV Type FRV Declaration of conformity Technical data Wiring diagram Parts list page 2 of 18 3 3 4 4 4 5 5 5 6 6 6 7 8 8 8 9 10 10 10 11 11 11 12 12 12 13 13 14 14 15 15 16 17 18
Operating Instructions
type F/FV/FRV
1 Safety
1.1 Dangers/Hazards
The scale-ice-machine type F/FV/FRV is constructed according to recognized safety regulations and is equipped with safety devices. All parts which may come in contact with ice/water are made of stainless steel or food compatible plastic. Moving parts (ventilator, motor and compressor) are covered for protection. Electrical equipment complies with DIN EN 60335-2-89. Prior to delivery function and safety are tested. However, in case of faulty operation, non-observance of operating instructions or improper use the following is endangered: health of operator scale-ice-machine and other material values of the user effective operation of the scale-ice-machine
All personnel engaged with set-up, operation and maintenance of the machine therefore have to: be accordingly qualified follow the specific directions of these instructions
DANGER
imminent danger to life and limb, failure to comply with instructions could result in death or serious injury
ATTENTION
potentially dangerous situation for machine or environment, failure to comply with instructions could result in damage to property information and employment advice, e.g. for assistance
Advice functional advice= requested for correct use of scale-ice-machine (control, use, operation)
page 3 of 18
Operating Instructions
type F/FV/FRV
DANGER
Set-up and maintenance shall only be done by electrically skilled persons. Intervention on the refrigeration equipment is reserved to refrigeration technicians authorized by the manufacturer.
page 4 of 18
Operating Instructions
type F/FV/FRV
On each short or long term shut-down the complete evaporating unit has to be: drained from water, disinfected and thoroughly cleaned (see point 5 et seqq.) DANGER
All moving parts (ventilator, motors and compressor) are covered against accidental contact.
The safety devices are to protect the operator and should therefore not be removed, altered or bridged: protective covers, motor protecting switch micro-fuse/fuse in switch case floater switch (water level) icing controller and pressure control device (thickness of ice/water shortage)
page 5 of 18
Operating Instructions
type F/FV/FRV
2 Transport/Installation/Storage
2.1 Transport/Storage
Scale-Ice-Machines type F and FV are delivered on pallet in cardboard, ready for installation, i.e. with power cable and plug. Scale-Ice-Machines type FRV are delivered on pallet in cardboard without refrigeration aggregate and have to be connected to an existing aggregate or one to be ordered. When transported/moved with pallet truck/ fork lift place forks between feet and machine frame. (Distance between floor and machine frame 100mm)
2.2 Set-Up/Installation/Connection
Place machine stable. Check for sufficient bearing capacity of floor or console respectively. Consider floor load (see technical data for weight of machine) Respect minimum distance of 40cm between back of machine and adjoining wall. ATTENTION Mains supply must be secured sufficiently and power socket is to be mounted close to the machine and easy accessible (length of power cable: 2m).
At the back of the machine the hoses drain and condensation water are attached for discharge or place suitable container below hose to collect water. fix drain hose to sewage
The drain of the machine must be higher than the entry of the sewage
Connect water intake hose to inlet water valve with an R threaded connection. Only connection to drinking water supply is allowed. Depending on the quality of the water it may be necessary to install a filter. Water and electrical installation shall be done by skilled persons.
ATTENTION
page 6 of 18
Operating Instructions
type F/FV/FRV
insert main plug open water tap turn main switch ON (only F 1200-6000, oil will be heated automatically) push button ON
Machine only starts after achievement of required water level in water basin (controlled by float switch). It then starts automatically. Check correct rotation of evaporator drum (see pointing arrow). Drum must always rotate towards the ice chute. ATTENTION
3 evaporator drum
Machine starts ice production after reaching the correct temperature (approx 5 minutes).
On each short or long term shut-down the complete evaporating unit has to be: drained from water, disinfected and thoroughly cleaned (see point 5 et seqq.) DANGER Ausgabe /Rev. 05/2011 page 7 of 18
Operating Instructions
type F/FV/FRV
3 Operation/Use
3.1 Construction/Controls
1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11.
ice ejection button drain (F/FV/FRV 120 6000) button ON/OFF (F/FV/FRV 120 160) or button ON (F/FV/FRV 300 6000) button OFF (F/FV/FRV 300 6000) geared engine (ice) distance controller switch box float switch tube leading to cooling unit ice scraper limit switch
page 8 of 18
Operating Instructions
type F/FV/FRV
3.2 Operation/Use
Turn on:
open water supply/tab push button ON place ice container beneath ice chute (respect approx. distance from ventilation grid of 5 cm)
Turn off:
open button ON ( F/FV/FRV 120 160) push button OFF (F/FV/FRV 300 6000) close water supply/tap push (white) button DRAIN water flows from water basin into drainage clean water basin (see point 5.1.1)
DANGER
On each short or long term shut-down the complete evaporating unit has to be: drained from water, disinfected and thoroughly cleaned (see point 5 et seqq.)
page 9 of 18
Operating Instructions
type F/FV/FRV
4 Troubleshooting
4.1 General
Prior to calling FUNK customer service in case of disturbance, please check the following table so you may perhaps solve the problem on your own. If the problem persists please feel free to contact us. Always consider the following: Prior to working at electrical or mechanical refrigeration appliances ALWAYS remove plug and secure against reconnection by accident.
DANGER
call refrigeration technician: he has to search for leak and seal it, then fill up freezing mixture R404A; applicable environmental regulations are to be observed call refrigeration technician
leakage condenser dirty clean condenser (with brush not high pressure equipment)
check distance from wall 40 cm air room. i.e. open window, clean ventilation grid of the machine call refrigeration technician call electrician to replace float switch call electrician to replace the water solenoid valve call refrigeration technician to adjust injection valve
injection valve displaced floater switch defect water solenoid valve displace injection valve displaced
page 10 of 18
Operating Instructions
type F/FV/FRV
Readjustment of injection valve The automatic injection valve is set at the works. After longer operation periods it may become necessary to readjust the valve. By turning the adjustment screw the injection of refrigerant increases or decreases. By pulling off the protective cap the adjustment screw becomes accessible (see drawing). Setting is correct when evaporator drum is evenly covered with ice. There should be no ice on the compressor.
4.3.2
ATTENTION
Setting of valves must be done by refrigeration technicians. Incorrect setting may damage the compressor. In this case there is no warranty and no liability.
page 11 of 18
Operating Instructions
type F/FV/FRV
Water basin has to be cleaned daily! On each short or long term shut-down the complete evaporating unit has to be: drained from water, disinfected and thoroughly cleaned (see point 5 et seqq.) Prior to emptying the water basin check whether hose drain is connected to sewage, otherwise place suitable container underneath.
DANGER
ATTENTION
gripping levers
figure 1 Release green ON button on front ( F 120 160) push red OFF button on front ( F 300 6000) close water supply/tap push white EMPTY button on front remove plug remove top cover open the front flap (see figure 1) remove the ice chute
plastic lid
Operating Instructions
type F/FV/FRV
unscrew knurled head screws from plastic lid (see figure 2) remove the plastic lid open gripping levers To avoid dirt-collecting scratches in the surface do not use pointed and sharp-edged cleaning equipment. For disinfection use Doyen F 40 cleaner which may be obtained from company Funk.
ATTENTION
remove water basin and clean thoroughly remove float switch and clean thoroughly clean distance rod and disinfect ends of rod clean side plates clean water intake on side plate replace float switch replace water basin and close gripping levers replace ice chute replace the plastic lid and fix it with knurled head screws close the front flap If plastic lid is not replaced and fastened correctly, machine cannot be switched on. ADVICE
replace top cover open water supply/tap release white EMPTY button supply electric power push green ON button
5.1.2
Evaporator drum, ice scraper and ice chute have to be cleaned daily.
5.1.3
Strainers have to be cleaned weekly In each solenoid valve (water intake and drain) is a strainer which has to be cleaned thoroughly under running water once per week.
page 13 of 18
Operating Instructions
type F/FV/FRV
5.1.4
Cleaning of condenser
Danger of short circuit. ATTENTION Clean condenser only with dry brush; high pressure cleaners or steam jets may damage fan motor.
5.1.5
Cleaning Schedule
cleaning water basin evaporator drum ice scraper float switch (incl. fastener) distance rod side plates water intake on side plate ice chute strainers condenser
when daily daily daily daily daily daily daily daily weekly weekly
who operator operator operator operator operator operator operator operator operator operator
page 14 of 18
Operating Instructions
type F/FV/FRV
5.2 Maintenance
For hygienic reasons the following parts have to be cleaned daily: water basin evaporator drum ice scraper ice chute float switch (incl. fastener) distance rods (+ disinfection of the ends) side plates water intake on side plate
ADVICE
For optimal function and conservation of value a yearly maintenance inspection through the manufacturer or an authorized refrigeration company should be carried out.
WHAT
WHEN
WHO
HOW
annual semi-annual
5.3 Disposal
Drain oil from compressor and freezing mixture prior to disposal and dispose of both liquids separately in accordance to applicable official regulations. Metal parts may be given to scrap processing.
Advice
To avoid environmental pollution it may be advisable to charter an authorized contractor with the disposal of the entire machine.
page 15 of 18
Operating Instructions
type F/FV/FRV
6. Exploded drawing
Evaporator F
position 1
quantity 4
position 11
quantity 1
2 3 4 5 6 7 8 9 10
1 1 1 3 1 2 2 1 1
ice scraper traverse holding rod front/back distance washer evaporator drum distance shaft axial bearing rotation insertion side plate arrive
12 13 14 15 16 17 18 19 20
1 1 1 1 1 1 2 1 1
tensioning lever water basin blocking flap side plate motorside coupling geared engine support bracket ice chute feed shaft
page 16 of 18
Operating Instructions
type F/FV/FRV
figure 1
figure 2
type FV 120 (figure 1) FV 160 (figure 1) FV 160 (figure 2) FV 300 (figure 2) FV 400 (figure 2)
Standard containers available with capacities of 600 kg, 975 kg and 1300 kg. Larger containers available on request. FUNK storage containers are made of stainless steel on the in- and outside. The containers come double-walled and have an insulation of approx. 30 mm. Ice can easily be taken out as theres only one flap to be opened. Please use a shovel or similar made out of plastic as other materials may damage the containers surface. All FV-type machines come with the mounted container and ready to use. For installation and set-up please refer to the instructions of the F-type machines. Ice-container should always be emptied completely and then cleaned thoroughly.
DANGER
On each short or long term shut-down the complete evaporating unit has to be: drained from water, disinfected and thoroughly cleaned (see point 5 et seqq.)
page 17 of 18
Operating Instructions
type F/FV/FRV
FRV types are ice machines without refrigeration aggregate which may be connected to an existing aggregate or one to be ordered. FRV types can be set-up in different ways, either individually, on a pad or with an ice chute into another room. FRV machines are delivered including wired switch box for the ice machines which should be connected according to the enclosed wiring diagram. The pipe cross sections have to correspond with the diameter of the pressure and suction pipe - see Technical Data. Please Note! 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. The electrical, refrigeration technical and sanitary installation must be done by respective technicians. When using FRV types check the respective refrigeration load (see section technical data) The data on pipe cross-section and other recommended parts for FRV types may also be taken from the technical data sheet The liquid line generally has to be connected via a solenoid valve. The solenoid valve is to be connected to clamps 1, N and PE of the switch box. Please use shielding gas when soldering the copper pipes on site to avoid impurities inside copper tubing. Please observe electrical supply data for connection. Regulations issued by the local energy supply agencies are to be observed. Electrical connection of power supply has to permit an all-polar disconnection at any time. The external control of the refrigeration aggregate or the multicompressor refrigeration system has to comply to the protection category of IP 54. Filling quantity of cooling agent depends on compressor-type and distance between compressor and icemachine and should be taken from technical data sheet of the compressor. Heat exchanger (type Danfoss HE or similar) must be connected between suction and liquid line.
Attention!
The ice machine has a slowing-down-relay for the drum. After turning off the machine the system voltage still has to be connected with clamps L1-L2-L3. The drum must be free of ice when it stops! Shut-off valves have to be installed in the fluid and suction pipes to allow the cut-off of the scale ice machine for maintenance or reparation.