Rack and Related Parts Sub-rack Circuit Boards Auxiliary Parts
Rack
1. 2000mm (H) 600mm (W) 600mm (D); 92kg; 2. 2200mm (H) 600mm (W) 600mm (D);101kg; 3. 2600mm (H) 600mm (W) 600mm (D); 112.3kg.
Power Box
-48V(1st way) -48V(2nd way) Acoustooptic Alarm mute switch test switch Indicator
MUTE
TEST
RUN
ALM BGND -48V1 -48V2 PGND -48V1 -48V2 RMU UPPERSUBRACK LOWERSUBRACK
Power switch of Power switch of the upper subrack the lower subrack
PMU board
Power Box
PDA: Power Distribution Adapter PMU: Power Monitor Unit OPU: Over-voltage protection Unit LVC: Low voltage control Unit
Power box
U OP
LVC PD A MU P
Cabinet
Power Box
Main switch of the first power supply
-48V1 -48V1
Main switch of the second power supply
PGND BGND
Bridge Rectifier
OPU
Bridge Rectifier
Filter
Copper Plate
LVC
PDA PMU
Sub rack communication Interface and various external interfaces
Upper sub rack power supply To Upper Sub rack Lower sub rack power supply To Lower Sub rack
PMU
1. Generates ringing current for order wire 2. Monitor the voltage of the power 3. Monitor temperature in the Rack 4. Monitors alarms 5. Communicate with the SCC board.
1. To select the operation / detection mode of PM. 2. To select whether the PMU communicates with lower (up) or upper subrack. 3. Under normal power input (-48/-60V), it is switched down. 4. Reserved.
1 2 3 4
Toggle switches
FAN
Fan Fan fuse
Handle
Indicator
Fan switch
Sub-rack
FB1/LPTR
Suspension loop
EIPC
External Interface
10 11 12
Slot Width
9 10 11 12 /P 16 16 16 16 16 4 4 4
share
XCL/XCE
IU slot Capacity 1 2 2 2 3 2 2
share
5 4
6 4
7 4
9 10 11 12 /P 4 2 2 2 2
share
F L B 1 T / U L P D R 9 8 E I P C 10
L T U
L T U
L T U
EtNt Phone
L T
L T
L T
L T U / F B 2
LTU: interface boards FB1/LPDR ,FB2: FB1, FB2, LPDR EIPC: EIPC
U U U
4 3
2 1
Back of fan
System Overview
IU IU IU IU IU IU IU
Cross-connect Unit
(High-order 96*96 VC-4) (Low-order 2016*2016 VC-12)
IU IU IU IU IU
Interface Unit
Interface Unit
Timing Unit
Auxiliary interface
Management interface
OptiX 2500+
PD1 : 32E1 PQ1 : 63E1 PM1 : 32E1/T1 PQM : 63E1/T1 PL3: 3 E3/T3 PD4: 2 E4
PPI: PDH Physical Interface LPA: Lower order path adaptation LPT: Lower order path termination HPA: Higher order path adaptation
Clock board
decoder
Mapping
encoder
Demapping
Micro-processor
MCU
Application
PM1/PQM
Support both E1 and T1 signal Provides 120o balanced E1 interface and 100o balanced T1 interface.
PD1/PQ1
Support E1 signal Provides 75o unbalanced interface and 120o balanced interface.
Function
Path Protection
Service path 2 2M signal 1 Protection path 3 Normal Service path check out TU-AIS 2 2M signal 1 Protection path 3 Abnormal
Function
Maintenance Function
LU
SDH
SDH
LU
P Q 1
loopback
TU-AIS:
Reasons: 1. Incorrect crossconnect configuration 2. Fiber broken
TU-LOP:
Reasons: Incorrect service configuration
ALARM
Major alarm
LP-RDI:
remote defect indication Reasons: Alarm such as TU-AIS and TU-LOP detected by the remote terminal
PS:
protection switch Reasons: protection switch has taken palce
LP-REI:
remote error indication Reasons: Bit error detected by the remote terminal
LP-SLM LP-TIM:
Reasons: V5 or J2 mismatch
Performance
Performance Event
Performance Event LP-BBE TUPJCHIGH TUPJCLOW Description of performance BIP-2 check bit error counting TU pointer positive justification counting TU pointer negative justification counting
Indicator
Green indicator: Operation status indicator
5 times per second :
the board is not in working status.
Indicator
Red indicator: Alarm Indicator
3 times per second :
critical alarm
constant on:
board failed
OptiX 2500+
RST
MST
MSP
MSA
HPT
SPI: SDH physical interface RST: Regenerator section termination MST: Multiplex section termination MSP: Multiplex section protection MSA: Multiplex section adaptation HPT: Higher order path termination
Bus interfac e
Supports multiple types of networking Various optical modules for different distances J1 Huawei SBS C2 according to the service
R-LOF:
Loss of frame Reasons: 1. Clock of upstream station failed 2. Too much bit error
AU-AIS:
Reasons: Service in VC4 level is broken.
AU-LOP:
Reasons: 1. Hardware failed 2. Wrong service configuration
HP-LOM:
loss of multiframe Reasons: 1. Hardware failed 2. Wrong service configuration
HP-RDI:
remote end defect indicate Reasons: remote end detect HP alarm
MS-REI:
remote end defect indicate Reasons: remote end detect B2 error
HP-REI:
remote end defect indicate Reasons: remote end detect B3 error
To next page
Data timing
LOS
Control bus
Microprocessor
Contro logicl
Mailbox
Description of performance
Laser temperature Output optical power
XCS Board
OptiX 2500+
XCS
Principle diagram and signal flow Functions, features and applications Alarms and performance Indicators Relationship with other boards
XCS board will be discussed in two parts Cross-connect unit and clock unit
XCS Board
Two cross-connect board with different cross-connect unit.
STM-1 signal connected space division cross
128X128 48X48
T-S-T cross
2016X2016 1008X1008
XCS XCL\XCE
96 32
Cross-connect Unit
Principle of cross-connect unit
Input 96 VC4 Input 32 VC4
Control Circuit
Cross-connect Unit
Alarms and Performance events
Emergent alarm TEMP-OVER
Reasons: Operation temperature over limit
Minor alarm PS
Reasons: Switching of multiplex section
Cross-connect Unit
Relationship with other boards
With SCC
get control command send running information
Clock Unit
Principle of cross-connect unit
SETS SETPI Synchronization
IU 75/120 receiving
E1
SETS
connector
11
75/120 transmitting
IU
MCU
11
11
Clock Unit
Synchronization mode(of system)
In maser/slave mode, we have master NE uses external clock or internal clock and slave NEs use interface clock.
BITS A
C B
arrow means the sending direction of clock signal
Clock Unit
Working mode of clock unit
BITS
Normal
clock signal is ok
Holding
frequency information stored holding 24h
C B
arrow means the sending direction of clock signal
Free oscillation
internal clock
Clock Unit
Function and Features
1. Generate system timing signal. Provides various clock and frame signals for system. Provide 2 ways of external timing signals,. 2.Phase-lock and trace 2 ways of external timing signals and 12 ways of timing signals of the interface units. 3.Process synchronization information status byte
Clock Unit
Alarms and Performance events
Emergent alarm EXTSYNLOS
Reasons: Loss of external synchronization source
S1-SYN-CHANGE
Reasons: Synchronization source switching under S1 byte mode
Clock Unit
Minor alarm SYNC-LOS
Reasons: Loss of synchronization source of high class
SYN-BAD
Reasons: Deterioration of synchronization source
Clock Unit
Relationship with other boards
with SCC
1.get control command 2.send running information
Clock Unit
Indicator
Running inddicator in yellow means what? The XCS\XCL board is in backup status Other status is same with all the other boards.
SCC Board
OptiX 2500+
SCC Board
Principle
to boards
mailbox OHP
to boards
CPU DCC
SCC Board
Functions and features
Sn
SEMF:
Manage local equipment
MCF:
SEMF
F interface
1. Communicate with
MCF
Q interface D1-D3 D4-D12
SCC Board
Software Function
BIOS
Boot the system, load and upgrade host software Self-check the SCC hardware DCC communication Accomplish real time supervision,
maintenance and management
Host Software
Consist of AM and CM
SCC Board
Applications
ID--- the only physical identification of NE
ON OFF D7 D6 D5 D4 D3 D2 D1 D0
ID=9, IP=129.9.0.9
SCC Board
Extend Connection
SCC Board
WAN Modem Connection (two ways)
NE A
NE A
NE B
NE D
NE B
NE D
NE C
Modem
X.25 interface
NE C
Serial interface
PSTN
Modem
Modem
PSTN
Modem
SCC Board
Alarms and Performance events
Emergent alarm MSP-INFO-LOSS
Reasons: Multiplex section node lost parameter
APS-FAIL
Reasons: Indicating failed protection switching
SCC Board
Minor alarm MAIL-ERR
Reasons: Mailbox communication error
WRG-BD-TYPE
Reasons: Wrong board type
FAN-FAIL
Reasons: Fan failure
SCC Board
Relationship with other boards
SCC Board
Principle of OHP unit
Interface adaptation CPU Asynchr. RS-232 interface device
Four Parts
Encoder/decoder
User circuit
SCC Board
Functions and features
1. Telephone
Telephone conference function Sub-network telephone conference function Sub-network outgoing connection function
L< 50m
VOICE SC
VOICE SC
SCC Board
2. Data interface
status
on--connection between NE and NM is ok flash--data transmitted between NE and NM when there's a call dialing in, the alarm indicator will quick flashes.
AUXILIARY UNIT
OptiX 2500+
D/A
A/D
CPU
BPA simultaneously implements the receiving and amplified transmission of one way of optical signal.
......
ABPA
SL64
Major Minor
Access Board
Service to external physical interface (protection) Selection unit
Working Protection Working Working Working board N board board 1 board 2 board 3
EIPC
Indicator
Running indicator flashing twice every second --tributary switching
Indicators: When the red indicator is on, the board is in switching status.
CMI decoder
Indicators: When the red indicator is on, the board is in switching status.
LPDR
LPDR Board (Line Protection Drive Board) transmits STM-1 signal from SQE board at IUP slot to every LPSW board.
Indicators: When the green indicator is on, the power supply is normal