General Information
MCAC-VTSM-2011-09
D series and 2
V series MDV.
In 2005, Midea cooperated with Hitachi, produced the No.1 modules AC Inverter V3 and digital scroll D3. In 2005, Midea cooperated with IR Company, founded united lab. In 2008, Midea launched out the MDV4, which is the R410A DC Inverter VRF and Modular design also. In 2010, the new MDV4+ was on sale, which owns the entirely DC Inverter technology and new low noise technology.
The AC load ratio of building is 30%-75%,the area is 55%, most of the AC runs in the mid load, so the mid load operation ratio control the whole year AC running charge.
Centralizing winding
Distributing winding
General Information
MCAC-VTSM-2011-09
Smooth sine wave DC Inverter Motor uses 180 sine wave vector drive technology to ensure transducer to output smooth curve, which show motor rotor speed to run smooth. While, common frequency motor outputs sawtooth wave not to precisely show motor speed, so its efficiency is low.
2.2.2 High efficiency DC Fan motor, saving power 50% According to the running load and pressure, it controls the speed of DC fun to achieve the min. energy consume, to reach the best effect. Used across entire range of models (from 8 to 64 HP). Efficiency improvement by up to 45% especially at low speed
Pressure sensor
DC Fan motor
High Pressure
General Information
MCAC-VTSM-2011-09
Motor rotor speed waves among 5r, and can rapidly match DC Inverter Compressor to output, and enhance efficiency in part load. 2.2.3 Optimize heat exchange design, Heat exchange efficiency increase 10% Optimized Heat-exchanger structure and material by CFD simulation and in part load V4+ outdoor unit owns 100% exchanger using ratio. By adoption of Pressure Sensor, EXV, and DC fan motor, V4+ has an obvious improvement on efficiency than previous products.
2.3 More flexible design 2.3.1 External static pressure enhanced up to 81.8Pa and air volume increase 10%.
Applied high static pressure propeller fan and the optimum fan guard for high external static pressure, to respond to a range of various installation environments. Midea now offers up to 81.8Pa (10 mm H2O) external static pressure specification as an option, just needs On-site adjustment) to meet the requirements of veranda installation. * Customization is required.
2.4 High Comfort 2.4.1 Optional outdoor units Silent Mode control
Night silent operation will be activated X (6, 8) hours after the peak temperature during daytime, and it will get back to normal operation after Y (8,10,12) hours. To run in low speed, low noise, min. 46.8dB (A)
General Information
MCAC-VTSM-2011-09
2.4.2 More Options for outdoor units High static pressure mode, 0 static pressure mode (default), silence mode in night mode, silence mode, super silence mode, and capacity priority mode 2.4.3 Optimized fan pass design, Enhanced outlet static pressure technology Increase the static pressure and decrease the loss of pressure. Decrease the input and decrease the noise level. Take 16HP for example.
General Information
MCAC-VTSM-2011-09
2.5 High Reliability 2.5.1 Alternative Cycle Duty operation of outdoor units
MDV4+ intelligent control, according to the system load, cyclically changes start-up sequence of multiple outdoor units, equalizes compressor duty and extends operation life-span.
2.5.3 Dynamic gas balance technology Dynamic vector balance tech., no need to install gas balance pipe:
High-precision pressure sensor monitors the system pressure on time and transfers the data to master unit Master unit sends the pressure date to every unit and make sure each outdoor unit in balance situation.
6 General Information
MCAC-VTSM-2011-09
2.5.4 High efficiency oil balance technology 2.10.1 Oil balance pipes set among the modules, and individual oil balance vector control ensures oil distribution among the modules to compressor smooth and reliable running. When one compressors oil is overfull, oil balance pipes and outlet pipes both send the oil to system, and then system in average distributes the oil to the other compressors. Oil balance diagram
Refrigerant flow direction Enter condenser Oil separator Discharge pipe Oil even pipe I
Suction pipe Discharge pipe Oil even pipe Oil basin
Adopts high efficient centrifugal-type oil separator, which separate the oil from discharged refrigerant with up to 99% effect to make all the lubricant discharged from compressor can be returned in time. New designed low pressure liquid receiver with high efficiency of oil-return effect. Oil balance ensures sufficient refrigerant lubricant supply. Elaborately designed oil-return hole, which ensure reliable oil-return for every compressor.
2.5.5 Oil return technology Centrifugal oil separator can be up to over 99% separating efficiency, which in time and efficiently send the oil to compressors to ensure compressor oil volume. System auto back oil design can complete through PC core send oil back instruction by system running time and state. The accumulator is large volume design, which can more save refrigerant to avoid liquid strike. Multi back oil holes can ensure compressor smooth back oil. 2.5.6 Intelligent soft start technology, rapidly enhance refrigerant cycle volume Compressor soft start complete low frequency and low current start by DC Inv. compressor, and to reduce strike to electric network. When start DC Inv. Compressor, system runs in large volume and offer more
General Information 7
MCAC-VTSM-2011-09
heating capacity. And use the start rapidly advantage of fixed frequency compressor to quickly up to output aim. Compressor soft start Compressor soft start complete low frequency and low current start by DC Inv. compressor, and to induce strike to electric network. Lubrication system soft start
2.6 Convenient for installation and service 2.6.1 Auto addressing Addressing outdoor units and indoor units are automatically done just by pressing the button of the controller.
The outdoor unit can automatically distribute the address to indoor units without any manual settings. Wired controller and wireless controller can enquiry and modify every indoor units address Up to 64 indoor units can be connected to one system and identified automatically
2.6.2 Super Wiring It is possible to enable the shared use of the wiring between indoor & outdoor units, as well the centralized control. Hence make it easy for the user to retrofit the existing system with a centralized control, by simply connecting it to the outdoor units.
PQE & XYE, just only one group of communication wire of PQE, achieved both of communication for indoor & outdoor unit and network. reversible communication , central controller can connect from indoor side or outdoor side at will
General Information
MCAC-VTSM-2011-09
Convenient electronic control check window. Can directly observe the operation status from the LED display, and directly press the FORCE COOLING / CHECK button.
Compressor is near the outside, and there is sample pipe system for convenient maintenance. Simplified internal Piping system makes the maintenance work easier and time reduction,
General Information
MCAC-VTSM-2011-09
3. Model Line Up
Outdoor units (Combination Unit): 8, 10 HP 12 ,14 ,16 HP
10
General Information
MCAC-VTSM-2011-09
General Information
11
MCAC-VTSM-2011-09
12300 15400 19100 24200 27300 30700 34100 38200 47800 54600 68200 85300 95500 1 1.25 36 1.3 1.6 45 1.6 2 56 2.0 2.5 71 2.3 2.8 80 2.6 3.2 90 2.9 3.6 100 3.2 4 112 4.0 5 140 5.0 6 160 5.7 8 200 7.1 9 250 8 10 280
One-way cassette
12
Two-way cassette
General Information
MCAC-VTSM-2011-09
MDV-D160T1/N1-B
Wall-mounted -S Type
MDV-D140DL/N1-C
MDV-D80Z/N1-F1(F2)B
MDV-D71Z/N1-F4(F5) MDV-D80Z/N1-F4(F5)
Console
The specifications, designs, and information in this book are subject to change without notice for product improvement. 13
MCAC-VTSM-2011-09
7. Nomenclature
1.1 Outdoor unit:
MDV D 28 Z / D D N1 A
Design Serial Number & Improved code Such as A1, A2, B1, B2, C, D, etc. Refrigerant type N1:R410A Omit for R22 Electrical Auxiliary Heater D: with EAH Omit for without EAH Motor Type D: DC Fan Motor Omit for AC fan Motor Indoor Unit Structural category Q4: Standard four way cassette Q4-A: Compact four way cassette Q2: Two way cassette T1: High Static Pressure Ductable Unit T2: Ductable Unit, such as T2-A3, T2-A5 T3: Low Pressure Static Pressure Ductable Unit DL: Ceiling & Floor Type G: Wall mounted Type, such as G-S, G-C, G-E1, etc. Z: Floor Standing (Z-F1, Z-F2: Exposed /Z-F3: Concealed) Cooling Capacity (100W) VRF Indoor Unit Multi - Digital - Variable
14 General Information