SD150

Standby Power Rating 188kVA 150kW 60Hz

Industrial Diesel Generator Set


EPA Certified Stationary Emergency

Prime Power Rating* 169kVA 135KW 60Hz


Generator image used for illustration purposes only

*EPA Certified Prime ratings are not available in the U.S. or its Territories for engine model year 2011 and beyond

features
Generator Set = PROTOTYPE & TORSIONALLY TESTED = UL2200 TESTED = RHINOCOAT PAINT SYSTEM = WIDE RANGE OF ENCLOSURES AND TANKS Engine = EPA COMPLIANT = INDUSTRIAL TESTED, GENERAC APPROVED = POWER-MATCHED OUTPUT = INDUSTRIAL GRADE Alternator = TWO-THIRDS PITCH = LAYER WOUND ROTOR & STATOR = CLASS H MATERIALS = DIGITAL 3-PHASE VOLTAGE CONTROL Controls = ENCAPSULATED BOARD W/ SEALED HARNESS = 4-20mA VOLTAGE-TO-CURRENT SENSORS = SURFACE-MOUNT TECHNOLOGY = ADVANCED DIAGNOSTICS & COMMUNICATIONS

benefits
4 4 4 4 PROVIDES A PROVEN UNIT ENSURES A QUALITY PRODUCT IMPROVES RESISTANCE TO ELEMENTS PROVIDES A SINGLE SOURCE SOLUTION

4 4 4 4

MEETS EPA STANDARDS ENSURES INDUSTRIAL STANDARDS ENGINEERED FOR PERFORMANCE IMPROVES LONGEVITY AND RELIABILITY

4 4 4 4

ELIMINATES HARMFUL 3RD HARMONIC IMPROVES COOLING HEAT TOLERANT DESIGN FAST AND ACCURATE RESPONSE

4 4 4 4

EASY, AFFORDABLE REPLACEMENT NOISE RESISTANT 24/7 MONITORING PROVIDES VIBRATION RESISTANCE HARDENED RELIABILITY

primary codes and standards

150 kW Diesel
1 of 5

150 kW Diesel

SD150
ENGINE SPECIFICATIONS General Make EPA Emissions Compliance EPA Emissions Reference Cylinder # Type Displacement - L (cu. in.) Bore - mm (in.) Stroke - mm (in.) Compression Ratio Intake Air Method Cylinder Head Type Piston Type Crankshaft Type Engine Governing Governor Frequency Regulation (Steady State) Lubrication System Oil Pump Type Oil Filter Type Crankcase Capacity - L (qts) Iveco/FPT Stationary Emergency See Emissions Data Sheet 6 In-Line 6.7 104 (4.09) 128 (5.2) 16.5:1 Turbocharged/Aftercooled 4- Valve Aluminum Forged Steel

application and engineering data


Cooling System Cooling System Type Water Pump Flow Fan Type Fan Speed (rpm) Fan Diameter (in.) Coolant Heater Wattage Coolant Heater Standard Voltage Fuel System Fuel Type Fuel Specifications Fuel Filtering (microns) Fuel Inject Pump Make Fuel Pump Type Injector Type Engine Type Fuel Supply Line - mm (in.) Fuel Return Line - mm (in.) Engine Electrical System System Voltage Battery Charging Alternator Battery Size (at 0C) Battery Group Battery Voltage Ground Polarity

2 of 5

Closed Belt Driven Centrifugal Pusher 2538 rpm 26 1500 240

Electronic Isochronous 0.25%

Ultra Low Sulfur Diesel Fuel ASTM 5 Electronic Engine Driven Gear Electronic Direct Injection 12.7(") 12.7(")

Gear Full-Flow 19.6 (20.7)

12VDC Std 995 CCA 31 12VDC Negative

ALTERNATOR SPECIFICATIONS Standard Model Poles Field Type Insulation Class - Rotor Insulation Class - Stator Total Harmonic Distortion Telephone Interference Factor (TIF) Standard Excitation Bearings Coupling Load Capacity - Standby Prototype Short Circuit Test 520 mm Generac 4 Revolving H H < 5% < 50 Permanent Magnent One- Pre Lubed & Sealed Direct, Flexible Disc 100% Yes Voltage Regulator Type Number of Sensed Phases Regulation Accuracy (Steady State) Digital 3 0.25%

CODES AND STANDARDS COMPLIANCE (WHERE APPLICABLE) NFPA 99 NFPA 110 ISO 8528-5 ISO 1708A.5 ISO 3046 BS5514 SAE J1349 DIN6271 IEEE C62.41 TESTING NEMA ICS 1

Rating Definitions: Standby Applicable for a varying emergency load for the duration of a utility power outage with no overload capability. (Max. load factor = 70%) Prime Applicable for supplying power to a varying load in lieu of utility for an unlimited amount of running time. (Max. load factor = 80%) A 10% overload capacity is available for 1 out of every 12 hours.

SD150
POWER RATINGS (kW) STANDBY Single-Phase 120/240VAC @1.0pf Three-Phase 120/208VAC @0.8pf Three-Phase 120/240VAC @0.8pf Three-Phase 277/480VAC @0.8pf Three-Phase 346/600VAC @0.8pf STARTING CAPABILITIES (sKVA) sKVA vs. Voltage Dip 480VAC Alternator Standard Upsize 1 Upsize 2 FUEL kW 150 200 250 10% 133 187 263 15% 199 280 395 20% 265 373 527 25% 332 467 658 30% 398 560 790 35% 464 653 922 10% 100 140 197 15% 149 210 296 150 kW 150 kW 150 kW 150 kW 150 kW Amps: 625 Amps: 520 Amps: 451 Amps: 226 Amps: 180 135 kW 135 kW 135 kW 135 kW 135 kW

operating data (60Hz)


PRIME Amps: 563 Amps: 468 Amps: 406 Amps: 203 Amps: 162

208/240VAC 20% 199 280 395 25% 249 350 494 30% 299 420 593 35% 348 490 692

Fuel Consumption Rates* STANDBY Fuel Pump Lift - in (mm) 36 (900) Total Fuel Pump Flow (Combustion + Return) 29 gph Percent Load 25% 50% 75% 100% gph 3.3 6.2 8.8 11.2 lph 12.5 23.5 33.5 42.2 Percent Load 25% 50% 75% 100% PRIME gph 3 5.6 7.9 10 lph 11.2 21.1 30.1 38.0

* Refer to "Emissions Data Sheet" for maximum fuel flow for EPA and SCAQMD permitting purposes. COOLING STANDBY Coolant Flow per Minute Heat Rejection to Coolant Inlet Air Max. Operating Radiator Air Temp Max. Operating Ambient Temperature Coolant System Capacity Maximum Radiator Backpressure COMBUSTION AIR REQUIREMENTS STANDBY Flow at Rated Power ENGINE STANDBY Rated Engine Speed Horsepower at Rated kW** Piston Speed BMEP rpm hp ft/min psi 1800 240 1559 257 PRIME 1800 216 1559 243 Exhaust Flow (Rated Output) Max. Backpressure (Post Silencer) Exhaust Temp (Rated Output) Exhaust Outlet Size (Open Set) cfm (m3/min) inHg (Kpa) F (C) NPT (male) cfm (m3/min) 440 (12.46) EXHAUST STANDBY 1050 (29.7) 1.5 (5.1) 895 (479) 101.6 (4) PRIME 1008 (28.5) 1.5 (5.1) 806 (430) 101.6 (4) PRIME 396 (11.21) gpm (lpm) BTU/hr cfm (m3/min) F (C) F (C) gal (L) in H2O 44.6 (169) 412,900 7,946 (13,502) 122 (50) 104 (40) 7.5 (28.4) 0.5 PRIME 44.6 (169) 368,700 7,946 (13,502) 122 (50) 104 (40) 7.5 (28.4) 0.5

** Refer to Emissions Data Sheet for maximum bHP for EPA and SCAQMD permitting purposes.

Deration Operational characteristics consider maximum ambient conditions. Derate factors may apply under atypical site conditions. Please consult a Generac Power Systems Industrial Dealer for additional details. All performance ratings in accordance with ISO3046, BS5514, ISO8528 and DIN6271 standards.

150 kW Diesel
3 of 5

150 kW Diesel

SD150
GENERATOR SET Genset Vibration Isolation IBC Seismic Certified/Seismic Rated Vibration Isolators Extended warranty Gen-Link Communications Software Steel Enclosure Aluminum Enclosure Std Opt Opt Opt Opt Opt CONTROL SYSTEM

standard features and options


Control Panel Digital H Control Panel - Dual 4x20 Display Digital G-100 Control Panel - Touchscreen Digital G-200 Paralleling Control Panel - Touchscreen Programmable Crank Limiter 21-Light Remote Annunciator Remote Relay Panel (8 or 16) 7-Day Programmable Exerciser Special Applications Programmable PLC RS-232 RS-485 All-Phase Sensing DVR Full System Status Utility Monitoring (Req. H-Transfer Switch) 2-Wire Start Compatible Power Output (kW) Power Factor Reactive Power All phase AC Voltage All phase Currents Oil Pressure Coolant Temperature Coolant Level Oil Temperature Fuel Pressure Engine Speed Battery Voltage Frequency Date/Time Fault History (Event Log) Low-Speed Exercise Isochronous Governor Control -40deg C - 70deg C Operation Waterproof Plug-In Connectors Audible Alarms and Shutdowns Not in Auto (Flashing Light) Auto/Off/Manual Switch E-Stop (Red Mushroom-Type) Remote E-Stop (Break Glass-Type, Surface Mount) Remote E-Stop (Red Mushroom-Type, Surface Mount) Remote E-Stop (Red Mushroom-Type, Flush Mount) NFPA 110 Level I and II (Programmable) Remote Communication - RS232 Remote Communication - Modem Remote Communication - Ethernet 10A Run Relay Alarms (Programmable Tolerances, Pre-Alarms and Shutdowns) Low Fuel Oil Pressure (Pre-programmed Low Pressure Shutdown) Coolant Temperature (Pre-programmed High Temp Shutdown) Coolant Level (Pre-programmed Low Level Shutdown) Oil Temperature Engine Speed (Pre-programmed Overspeed Shutdown) Voltage (Pre-programmed Overvoltage Shutdown) Battery Voltage Other Options

4 of 5

ENGINE SYSTEM General Oil Drain Extension Oil Make-Up System Oil Heater Air cleaner Fan guard Radiator duct adapter Fuel System Fuel lockoff solenoid Secondary fuel filter Stainless steel flexible exhaust connection Industrial Exhaust Silencer Critical Exhaust Silencer Flexible fuel lines Primary fuel filter Single Wall Tank (Export Only) UL 142 Fuel Tank Cooling System 120VAC Coolant Heater 208VAC Coolant Heater 240VAC Coolant Heater Other Coolant Heater_______________________ Closed Coolant Recovery System UV/Ozone resistant hoses Factory-Installed Radiator Radiator Drain Extension Engine Electrical System Battery charging alternator Battery cables Battery tray Battery box Battery heater Solenoid activated starter motor 10A UL float/equalize battery charger Rubber-booted engine electrical connections Std Std Std Std Opt Opt Opt Opt Opt Opt Opt Std Std Std Std Std Std Std Opt Opt Std Opt Std Std Opt Opt Std Std Std

Std na na Std Opt Opt Std Std Std Std Std Std Std Std Std Std Std Std Std Std Std Std Opt Std Std Std Std Std Std Std Std Std Std Std Std Opt Opt Opt Std Std Opt Opt Opt Opt Std Std Std Std Std Std Std

ALTERNATOR SYSTEM UL2200 GENprotect Main Line Circuit Breaker 2nd Circuit Breaker 3rd Circuit Breaker Alternator Upsizing Anti-Condensation Heater Tropical coating Permanent Magnet Generator Std Opt Opt Opt Opt Opt Std

SD150
OPEN SET

dimensions, weights and sound levels


RUN TIME HOURS USABLE CAPACITY (GAL) 134 322 510 693 946 1325 L 117 117 117 117 136 208 278 W 50 50 50 50 53 53 53 H 57 70 82 94 98 98 96 WT 3980 4764 5025 5345 5575 7005 8020 88 dBA*

NO TANK 12 29 45

62 84 118 WEATHERPROOF ENCLOSURE RUN TIME HOURS

USABLE CAPACITY (GAL) 134 322 510 693 946 1325

L 143 143 143 143 143 208 278

W 50 50 50 50 53 53 53

H 68 81 93 105 109 109 107

WT 4845 5629 5917 6210 6440 7870 8885

dBA*

NO TANK 12 29 45 62

81

84 118 LEVEL 1 SOUND ENCLOSURE RUN TIME HOURS NO TANK

USABLE CAPACITY (GAL) 134 322 510 693 946 1325

L 168 168 168 168 168 234 304

W 50 50 50 50 53 53 53

H 68 81 93 105 109 109 107

WT 5230 6014 6302 6595 6825 8255 9270

dBA*

12 29 45 62

76

84 118 LEVEL 2 SOUND ENCLOSURE RUN TIME HOURS NO TANK

USABLE CAPACITY (GAL) 134 322 510 693 946 1325

L 143 143 143 143 143 208 278

W 50 50 50 50 53 53 53

H 92 105 117 129 133 133 131

WT 5108 5892 6180 6473 6703 8133 9148

dBA*

12 29 45 62 84

73

118

* All measurements are approximate and for estimation purposes only. Weights are without fuel in tank. Sound levels measured at 23ft (7m) and does not account for ambient site conditions.

Tank Options MDEQ Florida DERM/DEP Chicago Fire Code IFC Certification ULC OPT OPT OPT CALL CALL

YOUR FACTORY RECOGNIZED GENERAC INDUSTRIAL DEALER

Other Custom Options Available from your Generac Industrial Power Dealer
Specification characteristics may change without notice. Dimensions and weights are for preliminary purposes only. Please consult a Generac Power Systems Industrial Dealer for detailed installation drawings.

Generac Power Systems, Inc. S45 W29290 HWY. 59, Waukesha, WI 53189 generac.com
2013 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Bulletin 0185000SBY-G / Printed in U.S.A. 04/17/13

150 kW Diesel