You are on page 1of 16

eW Cove EC Powercore

Cost-effective linear interior LED cove and accent fixture with solid white light

eW Cove EC Powercore

Cost-effective linear interior LED cove and accent fixture with solid white light
eW Cove EC Powercore is a dimmable, linear LED fixture that provides an affordable, energy-efficient alternative to traditional cove lighting in applications requiring white light. With its low profile, rotating housing and flexible end-to-end locking power connectors, eW Cove EC Powercore is the perfect choice for a wide range of interior retail, exhibit, hospitality, and architectural settings. Integrates patented Powercore technology Powercore rapidly, efficiently, and accurately controls power output to fixtures directly from line voltage, eliminating the need for an external power supply. Contractor-friendly installation dramatically simplifies installation and lowers total system cost. Warm and cool color temperatures Warm 2700 K fixtures are appropriate for intimate, open environments such as restaurants and hotel lobbies. Cool 4000 K fixtures are appropriate for lighting clean and efficient spaces such as offices, classrooms, and hospitals. Support for multiple voltages eW Cove EC Powercore accepts power input of 100, 120, or 220 240 VAC for consistent installation and operation from line voltage in a variety of locations. Dimming capability Patented DIMand technology offers smooth dimming capability with selected commercially available reverse-phase ELV-type dimmers.

Compact and flexible eW Cove EC Powercore low-profile fixtures fit in narrow alcoves, display cases, light boxes, and other tight spaces where light sources requiring ballasts, external power supplies, and other auxiliary equipment can not. Sizes of 12 in (305 mm) and 6 in (152 mm) offer further flexibility in positioning. Easy installation Powercore delivers line voltage directly to the fixtures, simplifying installation by eliminating the need for external power supplies and allowing long product runs. Easy-to-install 4 ft (1.2 m) mounting tracks allow quick project setup in linear applications. Flexible mounting and positioning With end- to-end locking power connectors that can make 180 turns, eW Cove EC Powercore fixtures are easy to position in even the most challenging mounting circumstances. Fixtures rotate in 10 increments through a full 180 for precise aiming and beam mixing. Optional mounting tracks support vertical and overhead positioning. 1ft (305 mm) and 5 ft (1.5 m) jumper cables can add extra space between fixtures.

Superior Binning Algorithm Sets New Standard for Color Consistency eW Cove EC Powercore exceeds the recognized standards for color quality to guarantee uniformity and consistency of hue and color temperature across LEDs, fixtures, and manufacturing runs.

eW Cove EC Powercore Product Guide

Warmth and Efficiency with eW Cove EC Powercore


eW Cove EC Powercore white-light LED fixtures offer a sustainable, low-maintenance alternative to linear incandescent or fluorescent systems. Old North Church Bostons Old North Church replaced its existing click-strip incandescent lighting with 130 eW Cove Powercore units, installed along interior niches of the churchs upper gallery. As shown on the cover and to the left, the eW Cove Powercore fixtures cast a warm glow along the churchs niches, while accentuating the historic arches and moldings. Not only do the LED fixtures consume six times less energy than the previous incandescent system (40 watts per eight-foot run, versus 240 watts), but the light sources also offer a projected useful life of 50,000 hours up to 25 times longer than the previous sources. With eW Cove Powercore fixtures in place, the management of Old North Church expects to cut energy consumption by nearly 85%. The fixtures low profile and simple line-power installation, courtesy of patented Powercore technology, enable them to fit in narrow alcoves and niches where traditional light sources that require ballasts, additional power supplies, and other equipment can not. For further efficiency and ease of use, the church can smoothly dim the eW Cove Powercore fixtures with their existing ELV-type dimmers. Flinstering Across the Atlantic, Flinstering, a fashionable restaurant in Breda, the Netherlands, uses LED lighting to create ambiance and atmosphere while benefiting from its long lifetime, low maintenance, simplicity of installation, and energy efficiency. Flinstering uses the high-quality white light offered by eW Cove Powercore for dramatic illumination and accenting. As shown here, eW Cove Powercore fixtures warmly illuminate the surface beneath the colored bottles behind the bar.

Photography: John Brandon Miller

Photography: Korff en van Mierlo

eW Cove EC Powercore Product Guide

Photometrics
Photometric data is based on test results from an independent NIST traceable testing lab. IES data is available at www.philipscolorkinetics.com/support/ies.

eW Cove EC Powercore 2700 K, 6 in (152 mm)


Lumens Efficacy 38 31.7 lm / W

Polar Candela Distribution


Cd: 0 3 5 8 10 13 15 VA: 0 10 - 0 H 20 30 - 90 H 40 90 80 70 60 50
0 5 15 25 35 45 55 65 75 85 90 0.0 11.9 11.9 11.5 10.7 9.6 8.3 6.7 5.1 3.6 2.2 1.7

Candela Table

Illuminance at Distance
90.0 11.9 11.9 11.5 10.6 9.4 7.8 5.9 4.0 2.1 0.6 0.2

22.5 11.9 11.9 11.5 10.7 9.6 8.2 6.7 5.0 3.4 2.1 1.6

45.0 11.9 11.9 11.5 10.7 9.5 8.1 6.4 4.7 3.1 1.7 1.1

67.5 11.9 11.9 11.5 10.6 9.4 7.9 6.1 4.2 2.4 1.0 0.5

Center Beam fc 0.7 ft 1.3 ft 2.0 ft 2.7 ft 3.3 ft 4.0 ft 27 fc 7 fc 3 fc 2 fc 1 fc .8 fc

Beam Width 2.3 ft 4.5 ft 6.8 ft 9.1 ft 11.3 ft 13.6 ft 1.9 ft 3.8 ft 5.7 ft 7.5 ft 9.4 ft 11.3 ft

5.8 ft (1.8 m) 1 fc maximum distance

Vert. Spread: 119.1 Horiz. Spread: 109.5

Zonal Lumen Zonal Lumen Summary


Zone 0- 30 0- 40 0- 60 0- 90 90-120 90-130 90-150 90-180 0-180 Lumens 9.3 15.3 27.2 36.6 1.3 1.3 1.4 1.4 38.0 %Fixture 24.5 40.2 71.6 96.4 3.3 3.5 3.6 3.6 100.0

Coefficients Of Utilization - Zonal Cavity Method


Effective Floor Cavity Reflectance: 20%

RC RW 0 1 2 3 4 5 6 7 8 9 10

80 70 50 30 10 118118118118 106101 96 92 96 87 80 73 87 76 67 60 80 67 58 51 73 60 50 43 67 53 44 37 62 48 39 33 58 44 35 29 54 40 32 26 51 37 29 24

70 70 50 30 10 115115115115 103 98 94 90 93 85 78 72 85 74 66 60 77 65 57 50 71 58 49 43 65 52 44 37 60 47 39 33 56 43 35 29 53 40 32 26 49 37 29 24

50 50 30 10 110110110 94 90 86 81 75 70 71 64 58 63 55 49 56 48 42 50 42 37 46 38 32 42 34 29 38 31 26 35 28 23

30 50 30 10 104104104 89 86 83 77 72 68 68 62 57 60 53 48 54 47 41 48 41 36 44 37 32 40 33 28 37 30 25 34 28 23

10 50 30 10 100100100 85 83 80 74 70 66 65 60 55 57 52 47 51 45 41 46 40 36 42 36 31 39 33 28 36 30 25 33 27 23

0 0 97 78 64 53 45 38 33 29 26 23 21

eW Cove EC Powercore 2700 K, 12 in (305 mm)


Lumens Efficacy 140 45.0 lm / W

Polar Candela Distribution


Cd: 0 8 17 25 33 42 50 VA: 0 10 - 0 H 20 30 - 90 H 40 90 80 70 60 50
0 5 15 25 35 45 55 65 75 85 90 0.0 45.1 45.1 43.5 40.5 36.1 30.7 24.7 18.7 13.0 8.3 6.3

Candela Table

Illuminance at Distance
90.0 45.1 44.9 43.2 39.8 35.1 28.8 21.8 14.6 7.6 1.7 0.4

22.5 45.1 45.0 43.4 40.3 35.9 30.5 24.5 18.3 12.5 7.7 5.7

45.0 45.1 45.0 43.3 40.2 35.6 30.0 23.6 17.1 11.1 6.0 4.0

67.5 45.1 44.8 43.2 39.9 35.2 29.2 22.3 15.4 8.8 3.4 1.6

Center Beam fc 0.7 ft 1.3 ft 2.0 ft 2.7 ft 3.3 ft 4.0 ft 101 fc 25 fc 11 fc 6 fc 4 fc 3 fc

Beam Width 2.2 ft 4.3 ft 6.5 ft 8.7 ft 10.9 ft 13.0 ft 1.8 ft 3.7 ft 5.5 ft 7.3 ft 9.1 ft 11.0 ft

8.6 ft (2.6 m) 1 fc maximum distance

Vert. Spread: 116.9 Horiz. Spread: 107.8

Zonal Lumen Zonal Lumen Summary


Zone 0- 30 0- 40 0- 60 0- 90 90-120 90-130 90-150 90-180 0-180 Lumens 35.0 57.3 101.3 135.5 4.3 4.5 4.6 4.6 140.1 %Fixture 25.0 40.9 72.3 96.7 3.1 3.2 3.3 3.3 100.0

Coefficients Of Utilization - Zonal Cavity Method


Effective Floor Cavity Reflectance: 20%

RC RW 0 1 2 3 4 5 6 7 8 9 10

80 70 50 30 10 117117117117 106101 96 92 96 87 80 74 87 76 68 61 80 67 58 52 73 60 51 44 68 54 45 38 63 49 40 34 58 45 36 30 54 41 33 27 51 38 30 25

70 70 50 30 10 114114114114 103 98 94 90 93 85 79 73 85 75 67 60 77 66 58 51 71 59 50 44 66 53 44 38 61 48 40 34 57 44 36 30 53 40 32 27 50 37 30 24

50 50 30 10 109109109 93 90 87 81 76 71 71 64 59 63 56 50 56 49 43 51 43 38 46 39 33 42 35 30 39 32 27 36 29 24

30 50 30 10 103103103 89 86 84 77 73 69 68 62 58 60 54 49 54 48 42 49 42 37 45 38 33 41 34 29 38 31 26 35 28 24

10 50 30 10 99 85 74 65 58 52 47 43 39 36 34 99 83 70 60 52 46 41 37 33 30 28 99 81 67 56 48 42 36 32 29 26 24

0 0 96 78 64 54 46 39 34 30 27 24 22

For lux multiply fc by 10.7

eW Cove EC Powercore Product Guide

eW Cove EC Powercore 4000 K, 6 in (152 mm)


Lumens Efficacy 41 36.4 lm / W

Polar Candela Distribution


Cd: 0 3 5 8 10 13 15 VA: 0 10 - 0 H 20 30 - 90 H 40 90 80 70 60 50
0 5 15 25 35 45 55 65 75 85 90 0.0 12.9 12.8 12.4 11.6 10.4 9.0 7.3 5.5 3.8 2.4 1.8

Candela Table

Illuminance at Distance
67.5 12.9 12.8 12.4 11.5 10.1 8.5 6.5 4.5 2.6 1.0 0.5 90.0 12.9 12.8 12.4 11.4 10.1 8.3 6.3 4.3 2.3 0.6 0.2

22.5 12.9 12.8 12.4 11.6 10.4 8.9 7.2 5.4 3.7 2.3 1.7

45.0 12.9 12.9 12.4 11.5 10.3 8.7 6.9 5.0 3.3 1.8 1.2

Center Beam fc 0.7 ft 1.3 ft 2.0 ft 2.7 ft 3.3 ft 4.0 ft 29 fc 7 fc 3 fc 2 fc 1 fc .8 fc

Beam Width 2.3 ft 4.6 ft 6.9 ft 9.2 ft 11.5 ft 13.7 ft 1.9 ft 3.7 ft 5.6 ft 7.5 ft 9.4 ft 11.2 ft

5.8 ft (1.8 m) 1 fc maximum distance

Vert. Spread: 119.6 Horiz. Spread: 109.1

Zonal Lumen Zonal Lumen Summary


Zone 0- 30 0- 40 0- 60 0- 90 90-120 90-130 90-150 90-180 0-180 Lumens 10.0 16.5 29.3 39.4 1.3 1.4 1.4 1.4 40.8 %Fixture 24.6 40.3 71.8 96.5 3.2 3.4 3.5 3.5 100.0

Coefficients Of Utilization - Zonal Cavity Method


Effective Floor Cavity Reflectance: 20%

RC RW 0 1 2 3 4 5 6 7 8 9 10

80 70 50 30 10 113113113113 102 97 92 88 92 83 76 70 84 73 64 58 76 64 55 48 70 57 48 41 64 51 42 36 60 46 37 31 55 42 34 28 52 38 30 25 48 35 28 22

70 70 50 30 10 110110110110 99 94 90 86 89 81 75 69 81 71 63 57 74 63 54 48 68 56 47 41 62 50 42 36 58 45 37 31 54 41 33 28 50 38 30 25 47 35 27 22

50 50 30 10 105105105 90 86 83 78 72 67 68 61 56 60 53 47 53 46 40 48 41 35 44 36 31 40 32 27 36 29 24 34 27 22

30 50 30 10 100100100 85 83 80 74 69 65 65 59 54 57 51 46 51 45 40 46 40 35 42 35 30 38 32 27 35 29 24 33 26 22

10 50 30 10 95 82 71 62 55 49 44 40 37 34 32 95 79 67 57 50 44 39 34 31 28 26 95 77 64 53 45 39 34 30 27 24 22

0 0 93 75 61 51 43 37 32 28 25 22 20

eW Cove EC Powercore 4000 K, 12 in (305 mm)


Lumens Efficacy 172 56.9 lm / W

Polar Candela Distribution


Cd: 0 9 18 28 37 46 55 VA: 0 10 - 0 H 20 30 - 90 H 40 90 80 70 60 50
0 5 15 25 35 45 55 65 75 85 90 0.0 54.0 54.0 52.3 49.0 44.2 38.0 30.7 23.2 16.0 10.0 7.6

Candela Table

Illuminance at Distance
90.0 54.0 53.7 51.9 48.1 42.7 35.4 26.9 18.0 9.3 2.1 0.4

22.5 54.0 53.8 52.2 48.9 44.0 37.7 30.4 22.7 15.4 9.4 7.0

45.0 54.0 53.9 52.1 48.7 43.5 37.0 29.2 21.2 13.7 7.4 4.9

67.5 54.0 53.6 51.8 48.3 43.0 35.9 27.6 19.1 10.9 4.1 1.9

Center Beam fc 0.7 ft 1.3 ft 2.0 ft 2.7 ft 3.3 ft 4.0 ft 122 fc 30 fc 14 fc 8 fc 5 fc 3 fc

Beam Width 2.3 ft 4.6 ft 6.9 ft 9.2 ft 11.5 ft 13.8 ft 1.9 ft 3.8 ft 5.7 ft 7.6 ft 9.5 ft 11.4 ft

8.8 ft (2.7 m) 1 fc maximum distance

Vert. Spread: 119.9 Horiz. Spread: 109.7

Zonal Lumen Zonal Lumen Summary


Zone 0- 30 0- 40 0- 60 0- 90 90-120 90-130 90-150 90-180 0-180 Lumens 42.2 69.5 123.9 166.0 5.3 5.6 5.8 5.9 171.9 %Fixture 24.6 40.4 72.1 96.6 3.1 3.3 3.4 3.4 100.0

Coefficients Of Utilization - Zonal Cavity Method


Effective Floor Cavity Reflectance: 20%

RC RW 0 1 2 3 4 5 6 7 8 9 10

80 70 50 30 10 117117117117 106100 96 92 96 87 80 74 87 76 68 61 79 67 58 51 73 60 51 44 67 54 45 38 62 49 40 34 58 44 36 30 54 41 32 27 51 38 30 24

70 70 50 30 10 114114114114 103 98 94 90 93 85 78 73 84 74 66 60 77 66 57 51 71 59 50 44 65 53 44 38 60 48 39 33 56 44 35 30 53 40 32 27 49 37 29 24

50 50 30 10 108108108 93 90 86 81 75 70 71 64 59 63 55 50 56 49 43 51 43 37 46 38 33 42 35 29 39 31 26 36 29 24

30 50 30 10 103103103 89 86 83 77 72 68 68 62 57 60 54 49 54 47 42 49 42 37 44 38 32 41 34 29 37 31 26 35 28 24

10 50 30 10 98 85 74 65 58 52 47 43 39 36 34 98 82 70 60 52 46 41 37 33 30 28 98 80 66 56 48 41 36 32 29 26 23

0 0 96 78 64 53 45 39 34 30 27 24 22

For lux multiply fc by 10.7

eW Cove EC Powercore Product Guide

Specifications
Due to continuous improvements and innovations, specifications may change without notice. Item Specification Beam Angle Color Temperature Lumens Output Efficacy (lm / W) CRI Lumen Maintenance Input Voltage Electrical Power Consumption Power Factor Control Dimming Dimensions (Height x Width x Depth) Weight Housing Lens Physical Fixture Connections Temperature Ranges Humidity Maximum Fixture Run Lengths Certification and Safety Certification Environment Energy Efficiency 6 in (152 mm) 110 x 110 2700 K* / 4000 K* 38 (2700 K) 41 (4000 K) 31.7 (2700 K) 36.4 (4000 K) 83 (2700 K) 84 (4000 K) 140 (2700 K) 172 (4000 K) 45.0 (2700 K) 56.9 (4000 K) 82 (2700 K) 83 (4000 K)
0 0 80

12 in (305 mm)

70,000 hours L70 @ 25 C 50,000 hours L70 @ 50 C 90,000 hours L50 @ 25 C 70,000 hours L50 @ 50 C 100 / 120 / 220 240 VAC, 50 / 60 Hz 1.5 W maximum at full output, steady state .96 @ 120 VAC Compatible with many commercially available ELV, trailing edge, or reverse-phase control dimmers 1.25 x 6 x 1.4 in (32 x 152 x 35 mm) 0.19 lbs (85 g) Clear polycarbonate Integral male / female connectors -4 122 F (-20 50 C) Operating -4 122 F (-20 50 C) Startup -40 176 F (-40 80 C) Storage 0 95%, non-condensing To calculate fixture run lengths and total power consumption for your specific installation, download the Configuration Calculator from www.philipscolorkinetics.com/support/install_tool/ UL / cUL, FCC Class B, CE, CCC, C-Tick, SAA Dry Location, IP20 California Title 24 Compliant 1.25 x 12 x 1.4 in (32 x 305 x 35 mm) 0.31 lbs (142 g) 3.0 W maximum at full output, steady state

Injection-molded plastic, dark-gray finish

* Color temperatures conform to nominal CCTs as defined in ANSI Chromaticity Standard C78.377A. Lumen measurement complies with IES LM-79-08 testing procedures. L70 = 70% lumen maintenance (when light output drops below 70% of initial output). L50 = 50% lumen maintenance (when light output drops below 50% of initial output). Ambient luminaire temperatures specified. Lumen maintenance calculations are based on lifetime prediction graphs supplied by LED source manufacturers. Calculations for white-light LED fixtures are based on measurements that comply with IES LM-80-08 testing procedures. Refer to www.philipscolorkinetics.com/support/appnotes/lm-80-08.pdf for more information. Refer to www.philipscolorkinetics.com/support/appnotes/ for specific details.
6 in (152 mm) 1.25 in (32 mm) 1.4 in (35 mm)

1.25 in (32 mm)

120V

120V

4.3 in (109 mm) 5.6 in (142 mm)

1 in (25 mm) 110 x 110 beam angle 12 in (305 mm)

1 in (25 mm)

60 x 115 beam angle

120V

120V

6.6 in (168 mm) 8.1 in (206 mm)

eW Cove EC Powercore Product Guide

To order eW Cove EC Powercore, select a line voltage connection option, a fixture length, and any extra options you might need.

Product Selection
Choose length

Choose fixture color temperature

Choose power

Choose line voltage connection option

Choose optional accessories

Permanent Installations

100 VAC 120 VAC


2700 K 4000 K

12 in (305mm)

Leader cable, UL / cUL, CE

220 240 VAC

6 in (152 mm)

5 ft (1.5 m) Jumper cable Wiring compartment, UL / cUL 1 ft (305 mm) Jumper cable

Portable Installations

Leader cable, UL / cUL

Mounting track

Fixtures
Item Type 2700 K 4000 K 2700 K 4000 K 2700 K 4000 K 2700 K 4000 K 2700 K 4000 K 2700 K 4000 K Size 6 in (152 mm) 12 in (305 mm) 6 in (152 mm) 12 in (305 mm) 6 in (152 mm) 12 in (305 mm) 6 in (152 mm) 12 in (305 mm) 12 in (305 mm) 12 in (305 mm) 12 in (305 mm) 12 in (305 mm) 6 in (152 mm) 6 in (152 mm) 12 in (305 mm) 12 in (305 mm) Item Number 523-000005-61 523-000004-61 523-000005-67 523-000004-73 523-000005-60 523-000004-60 523-000005-66 523-000004-72 523-000004-62 523-000004-74 523-000004-76 523-000004-77 523-000005-68 523-000005-69 523-000004-63 523-000004-75 Philips 12NC 910503701061 910503701045 910503701067 910503701057 910503701060 910503701044 910503701066 910503701056 910503701046 910503701058 910503701672 910503701673 910503704243 910503704244 910503701047 910503701059 eW Cove EC Powercore, 100 VAC

eW Cove EC Powercore, 120 VAC

eW Cove EC Powercore, 220 240 VAC / CE eW Cove EC Powercore, 220 240 VAC / CCC eW Cove EC Powercore, 220 240 VAC / CE / CCC eW Cove EC Powercore, 220 240 VAC / CE Fixture and 10 ft (3 m) Leader Cable with terminator

Use Item Number when ordering in North America.

eW Cove EC Powercore Product Guide

Accessories
Item Type UL / cUL Size 10 ft (3 m) Item Number 108-000032-00 Philips 12NC 910503700586 Leader Cable with terminator and strain relief For connection to standard junction box

CE

10 ft (3 m)

108-000032-02

910403325901 Can be used for direct connection to conduit

Wiring Compartment with terminator

UL / cUL

120-000076-00

910503700597

Leader Cable with plug

UL / cUL

8 ft (2.4 m)

108-000032-03

910503700394

For portable installations

1 ft (305 mm) UL / cUL Jumper Cable CE 5 ft (1.5 m) 1 ft (305 mm) 5 ft (1.5 m)

108-000033-00 108-000033-01 108-000033-02 108-000033-03

910403600101 910403600102 910403326001 910403326101 Depending on the installations design, you may need jumper cables to add space between fixtures

Mounting Track

4 ft (1219 mm)

523-000006-01

910503700452

Optional mounting track ensures straight runs of fixtures

UL / cUL Wiring Compartment

1.75 in (44.5 mm)

.875 in (22.2 mm) 1.25 in (31.8 mm) 4.375 in (111.1 mm)

1.75 in (44.5 mm)

eW Cove EC Powercore Product Guide

Included in the box


eW Cove EC Powercore fixture Installation Instructions

Installation
eW Cove EC Powercore offers high-output, energy-efficient indoor solid white alcove lighting with Powercore technology. Powercore, which delivers line voltage directly to the fixture, eases installation by eliminating the need for external power supplies or special wiring. Owner / User Responsibilities It is the responsibility of the contractor, installer, purchaser, owner, and user to install, maintain, and operate eW Cove EC Powercore fixtures in such a manner as to comply with all applicable codes, state and local laws, ordinances, and regulations. Consult with the appropriate electrical inspector to ensure compliance.

E Refer to the eW Cove EC Powercore Installation Instructions for specific warning and caution statements.

Create a Layout Plan


Regardless of the size and complexity of your installation, the time you spend up front can help minimize installation and configuration issues later. Keep these suggestions in mind as you plan your installation: 1. On an architectural diagram or other diagram that shows the physical layout of the installation, create a layout map that specifies the appropriate location of the light fixtures in relation to each other, and to any dimmer switches, wall switches, and line power sources. Identify any obstacles or physical features requiring flexible jumper cables between fixtures. 2. Using the fixtures power consumption and efficiency ratings, the lighting designer or architect should calculate the cove dimensions to ensure that operating temperatures remain within safe levels. The designer or architect should also determine the coves fascia design and fixture setback based on the cove dimensions and room width. For consistent results, the cove width and height should accommodate the fixtures minimum mixing distances. We strongly recommend creating dimensional models and mockups prior to installation.
eW Cove EC Powercore 110 Beam angle, 180 rotation

Easy turns
End-to-end locking power connectors can make turns of up to 180 without jumper cables.

40

50

60

70

80

90

100

110

E Minimum cove height is mixing distance + height of fixture to LED board.

Minimum cove height 2.75 in (70 mm)

Distance between fixtures


.125 in (3 mm)

Minimum fixture standoff 2.125 in (54 mm)

120V

120V

4.5 in (114 mm) .625 in (16 mm)

3. eW Cove EC Powercore fixtures are installed in series. The in-line connectors allow end-to-end fixture connections for the best visual effects. When installing fixtures end-to-end, allow a minimum distance of .125 in (3 mm) between fixtures, and a maximum distance of .625 in (16 mm). For more spacing between fixtures, use the 1 ft (305mm) or 5 ft (1.5 m) jumper cables. 4. You can install a run of eW Cove EC Powercore fixtures using the 10 ft (3 m) Leader Cable with flying leads. This option is preferable when connecting to a thirdparty junction box, or when retrofitting an existing incandescent or fluorescent cove lighting installation. In North America, you can use the Wiring Compartment when you want to run branch conduit all the way to the first fixture in a series, or where local codes require it. You can also create a portable installation by using the 8 ft (2.4 m) Leader Cable with plug.
eW Cove EC Powercore Product Guide 9

120V

120V

5 in (128 mm)

5. If fixtures are installed end-to-end on a 20 A circuit using the standard 10 ft (3 m) Leader Cable, each run can accommodate up 100 12 in (305 mm) fixtures, or up to 150 6 in (152 mm) fixtures. Using the optional jumper cables can decrease the number of fixtures that you can connect in a single run.

Install Wall and Dimmer Switches (optional)


eW Cove EC Powercore fixtures can be controlled either with a standard wall switch (on / off) or a compatible, commercially available electronic low-voltage (ELV) dimmer. eW Cove Powercore fixtures work with selected commercially available reverse-phase ELV-type dimmers. For a list of compatible ELV dimmers, and for details on selecting the appropriate dimmer for your lighting installation, visit www.philipscolorkinetics.com/support/ appnotes, or consult Application Engineering services at support@colorkinetics.com.

E To calculate the number of fixtures your specific installation can support, download the Configuration Calculator from www.philipscolorkinetics.com/support/ install_tool/, or consult Philips Color Kinetics Application Engineering Services at support@colorkinetics.com.

E Refer to the installation instructions included with the wall or dimmer switch for installation and wiring information.

Prepare for the Installation


1. Verify that all supporting equipment (switches, line power sources) is in place. 2. If your installation calls for jumper cables to add space between fixtures, make sure they are available. 3. Ensure that all additional parts (optional mounting tracks, mounting hardware, terminators) and tools are available.

Install the Fixtures


You can mount eW Cove EC Powercore fixtures directly to a wall, ceiling, cabinet, or other secure surface. You can install several eW Cove EC Powercore fixtures in optional 4 ft (1.2 m) lengths of mounting track to ensure a straight run. (Optional) Install Mounting Tracks 1. Field-cut the mounting tracks to the desired length with a hacksaw or tin snips. 2. Install the mounting tracks using hardware suitable for the mounting surface. To ensure proper fixture fit, hardware must not extend above the track standoffs after installation. The recommended maximum spacing between screws is 12 in (305 mm).
E You can use the fixture base as a template when pre-drilled pilot holes are required. Hold the fixture in place and mark the four screw holes.

OK

10

eW Cove EC Powercore Product Guide

Mount and Connect the Fixtures Make sure the power is OFF before mounting and connecting eW Cove EC Powercore fixtures. 1. Rotate an eW Cove EC Powercore fixture as necessary to provide unobstructed access to the mounting holes. 2. Position the first fixture in a series. If using mounting tracks on a horizontal surface, snap the fixture into the track. If using mounting tracks on vertical or overhead surfaces, or if not using mounting tracks, attach the fixture with four #6 (3.5 mm) mounting screws (not included) suitable for the mounting surface. Ensure that the male connector is in position to receive power from the female connector on the Leader Cable or Wiring Compartment. 3. Position the next fixture in the series, matching the male connector end to the female connector of the previously mounted fixture. Attach the fixture to the surface or snap it into the track.
1 ft. or 5 ft Jumper Cable

End-to-End

Terminator

CLICK!

4. Continue mounting the fixtures, making power connections as you go, until all lights in the series are mounted. 5. Insert the provided terminator into the last fixture in the series. 6. Make power connections.

eW Cove EC Powercore Product Guide

11

To run power or conduit to the first fixture in a series (permanent, UL / cUL installations): Remove the cover from the eW Cove Powercore Wiring Compartment. Using wire nuts, connect ground, neutral, and line inside the Wiring Compartment housing, then replace the cover.

Connect the eW Cove Powercore Wiring Compartment to the first fixture in the series.

Leader Cable connector dimensions


.375 in (9.5 mm) .675 in (15.9 mm) .375 in (9.5 mm) .675 in (15.9 mm) 1.25 in (31.8 mm) 1.13 in (28.6 mm)

1.25 in (31.8 mm

To connect the first fixture in a series to a third-party junction box using the 10 ft (3 m) Leader Cable (permanent installation): Remove the cover of the third-party junction box. Connect ground, neutral, and line inside the junction box housing, then replace the junction box cover. Connect the 10 ft (3 m) Leader Cable to the first fixture in the series.

12

eW Cove EC Powercore Product Guide

For portable installations (UL / cUL): Plug the 8 ft (2.4 m) Leader Cable into a suitable switched outlet. Connect the Leader Cable to the first fixture in the series.

For CE installations: Connect the Leader Cable to a terminal block. The terminal block must conform to EN 60998-2-1 or EN 60998-2-2, rated 220240 VAC. Connect ground, neutral, and line to a power source. Connect the Leader Cable to the first fixture in the series.

E Do not look directly into the fixture when aiming and locking.

Aim the Fixtures


Make sure the power is ON before aiming fixtures. Aim the fixtures by rotating each fixture to the correct angle. There are detents every 10 in the bracket that hold the fixture in position.

0 80 0

eW Cove EC Powercore Product Guide

13

14

eW Cove EC Powercore Product Guide

eW Cove EC Powercore Product Guide

15

Philips Color Kinetics 3 Burlington Woods Drive Burlington, Massachusetts 01803 USA Tel 888.385.5742 Tel 617.423.9999 Fax 617.423.9998 www.philipscolorkinetics.com

Copyright 2010 2013 Philips Solid-State Lighting Solutions, Inc. All rights reserved. Chromacore, Chromasic, CK, the CK logo, Color Kinetics, the Color Kinetics logo, ColorBlast, ColorBlaze, ColorBurst, ColorGraze, ColorPlay, ColorReach, iW Reach, eW Reach, eW Fuse, DIMand, EssentialWhite, eW, iColor, iColor Cove, IntelliWhite, iW, iPlayer, Optibin, and Powercore are either registered trademarks or trademarks of Philips Solid-State Lighting Solutions, Inc. in the United States and / or other countries. All other brand or product names are trademarks or registered trademarks of their respective owners. Due to continuous improvements and innovations, specifications may change without notice. Cover Photo: Old North Church, by John Brandon Miller DAS-000070-00 R07 10-13