You are on page 1of 2

* Equivalent materials ** Option

]
]
]
]
]
]
]
]
]
]
,
,
,
,
,
No.
Body
Cover
Float
Holder Nut Gasket
Valve Seat Holder O-Ring
Valve Seat
Nameplate
Valve Seat Holder Nut
Balancing Plug
Alignment Pin
Cover Gasket
Screen
Cover Bolt
Cleaning Needle
Needle O-Ring
Coil Spring
Split Pin
Plunger
Guard Bushing
Valve Seat Holder
Snap Ring
Washer
Drain Plug Gasket**
Drain Plug**
0.7043
0.7040
1.4404
PTFE
NBR
NBR
1.4301
1.4028
1.0037
1.2067
PTFE
1.4016
1.0503
1.4028
NBR
1.4301
1.4301
1.4028
1.0035
1.4028
1.4301
1.4301
1.1121
1.1158
A395
A536
AISI316L
PTFE
D2000BF
D2000BF
AISI304
AISI420F
A6
A485
PTFE
AISI430
AISI1045
AISI420F
D2000BF
AISI304
AISI304
AISI420F
A53 Type F
AISI420F
AISI304
AISI304
AISI1010
AISI1025
Ductile Cast Iron GGG40.3
Ductile Cast Iron FCD450
Stainless Steel SUS316L
Fluorine Resin PTFE
Nitrile Rubber NBR
Nitrile Rubber NBR
Stainless Steel SUS304
Stainless Steel SUS420F
Carbon Steel SS400
Bearing Steel SUJ2
Fluorine Resin PTFE
Stainless Steel SUS430
Carbon Steel S45C
Stainless Steel SUS420F
Nitrile Rubber NBR
Stainless Steel SUS304
Stainless Steel SUS304
Stainless Steel SUS420F
Carbon Steel SGP
Stainless Steel SUS420F
Stainless Steel SUS304
Stainless Steel SUS304
Soft Iron SUYP
Carbon Steel S25C
Description Material ASTM/AISI
*
DIN
*
9
2
10
12
21 6 5 14 4 15 8 16
17
20 19 18
7
13
11
3
1
22
23
24
SDS U3200-04
Light free float air trap for pipe-end installa-
tion to automatically drain condensate and
oil from compressed air systems.
1. Self-modulating free float provides soft,
continuous, and smooth, low velocity
discharge as process loads vary.
2. Perfect air-tight seal, even under low-load
conditions.
3. Only one moving part, the free float,
eliminates concentrated valve wear and
provides long maintenance-free service life.
4. Built-in screen with large surface area
ensures trouble free service.
5. Manual blow down device allows cleaning of
the valve seat from outside during operation.
6. Easy, inline access to internal parts simplifies
cleaning and reduces maintenance costs.
7. Major internal parts made of stainless steel.
Features
Specifications
1 bar = 0.1 MPa
Model
Connection
Size
Maximum Operating Pressure (barg) PMO
Maximum Differential Pressure (bar) PMO
Maximum Operating Temperature (C) TMO
JA3
Screwed
1
2,
3
4, 1
16
16
100
AIR TRAP
PRESSURE SHELL DESIGN CONDITIONS (NOT OPERATING CONDITIONS): Maximum Allowable Pressure (barg) PMA: 21
Maximum Allowable Temperature (C) TMA: 100
MODEL JA3 DUCTILE CAST IRON
To avoid abnormal operation, accidents or serious injury, DO NOT use this product outside of the specification range.
Local regulations may restrict the use of this product to below the conditions quoted.
CAUTION
FREE FLOAT DRAIN TRAP WITH TIGHT SHUT-OFF FOR AIR SERVICE
Dimensions
Discharge Capacity
JA3 Screwed
300
200
100
80
60
40
30
0.1 0.2 0.4 0.6 0.8 1 2 4 6 8 10 16
Differential Pressure (bar)
C
o
l
d

W
a
t
e
r

C
a
p
a
c
i
t
y

(
k
g
/
h
)
1 bar = 0.1 MPa
SDS U3200-04 Rev. 1/2007
Specifications subject to change without notice.
NOTE
A pressure-balancing line must be connected to the air system
from the balancing port at the top of the trap to a place above
any possible condensate accumulation in the system.
1. Differential pressure is the difference between the inlet and outlet pressure of the trap.
2. The chart is applicable to condensate below 100 C.
3. The discharge capacity is for a liquid with specific gravity of 1.
4. Recommended safety factor: at least 1.5.
DO NOT use traps under conditions that exceed maximum differential pressure,
as condensate backup will occur!
CAUTION
W
L
H
1
H
BSP c /H
130
* BSP DIN 2999, other standards available
Size
1
2
3
4
1
L
120
H
137
H1 W
75
80 73
75
Weight (kg)
2.7
2.8
3.0
JA3 Screwed
*
(mm)