Reciprocating Pump Catalog

National Oilwell Pumps


Wheatley Gaso Pumps
Omega Pumps

Selecting a NOI Reciprocating Pump


A reciprocating pump is a positive displacement machine,
liquid discharge pressure being limited only by the strength
of the structural parts. Liquid volume or capacity delivered
is constant regardless of pressure, and is varied only by
driver speed, speed reduction, and/or plunger/piston
size changes.
Determining plunger or piston rod load, calculating volumetric
efficiency, and evaluating the types of devices available for
pulsation control and inlet/discharge are critical in the pump
selection process.

Reciprocating Pump Selection: The Basics


The Fluid
Understanding the characteristics of the fluid being pumped
is essential to making the correct reciprocating pump selection
for your application. To make the proper pump selection,
you will need to know:
What is the fluid composition (including % and type of
solids present)
What are temperatures at inlet and outlet
What is the specific gravity of liquid at outlet and inlet
pressures and temperatures.
Are corrosives and/or abrasives present in the liquid
What is Vapor pressure at pumping temperature
What is the viscosity of liquid at pumping temperature
The Capacity
Determining the gallons per minute, barrels per hour or barrels
per day required to meet the needs of the application is
critical in pump selection process.
The Pressure
Evaluating the pressure conditions required for any pumping
application will be required before the correct NOI reciprocating
pump can be identified. To ensure correct selection, you
will need to know.
What is the required liquid pressure at discharge
What is the required liquid pressure at inlet/suction (NPSHR)
Other factors can play a significant role in pump selection:
Electrical hazards
Flange rating required
Preferred/specified metallurgy of major parts
Driver type
Space limitation/constraints
Site ambient temperature range
Indoor/outdoor application
Storage/future use considerations
The following conversion charts and engineering data will
assist you determining the essential items identified above.
The comprehensive evaluation of these items will ensure
that you are utilizing the best available NOI reciprocating
pump technology for your application.
For specific recommendations or engineering assistance,
please consult your NOI sales representative.

Formulas and factors to help pick the right pump.


It is easy to select the right multiplex pump to best meet
your anticipated volume and pressure requirements.
First calculate the hydraulic horsepower.
Then determine the input horsepower required. Use
input horsepower to identify the smallest pump suitable
for the application or the combination of pumps needed
to meet the total requirement.
Further selection of plunger size and operating speed
will tailor the pump to your volume and discharge
pressure requirements.
Helpful sizing formulas
hyd. hp = gpm x psi x .00058
hyd. hp = bbl/day x psi x .000017
hyd. hp = gpm x psi/1714
hyd. hp = bbl/day x psi/58,800
input hp = hyd. hp/mech. eff.
bbl/day = gpm x 34.285
bbl/day = m3/d x 6.2897
bbl/day
gpm = BDP/34.285
gpm = bbl/day x .02916
feet water = psi x 2.31
psi = feet water x .433
psi = kg/cm2 x 14.223
m/d = bbl/day
6.2897
kg/cm2 = Psi x .0703
mm = inches x 25.4
kg = pounds x .45359
liter = gallons x 3.785

Application
Plunger pumps for fluid injection projects.
The simplest plunger pump installation is in reality a
complex hydraulic system.
While it is not possible to anticipate all of the operational
peculiarities of a pump installation, it is to the operators
advantage to consider certain well-known design factors
and incorporate these factors into the station arrangement.
The following will help determine these factors.
Suction pressure
Plunger pumps have certain characteristics which must be
considered in designing the pump inlet system to assure
satisfactory performance. A positive inlet pressure is
required by a plunger pump while running to enable it to fill
on each stroke. This pressure is referred to as Net Positive
Inlet Pressure (NPIP) and is measured on the absolute
pressure scale. Fig. 1 shows that absolute pressure is the
sum of local barometric pressure plus gauge pressure.
NPIP is affected by many factors: pump speed, plunger
diameter, valve type and through area, valve spring load,
temperature, and vapor pressure of liquid being pumped
as well as local uncorrected barometric pressure.
A conservative approach to designing a pump inlet system
is to assume that any plunger pump in water injection service
requires a minimum NPIP of 15 psia, above vapor pressure,
while running. Obviously any NPIP above this minimum will
result in improved fluid end performance and provides
insurance against unpredictable changes in operating
conditions such as an increase in water temperature,
lower tank water level, gas entrainment, etc.

Major positive and negative pressures in a pump inlet system:


Positive
A. Liquid Level above Pump Inlet (psi) = (feet x .433)
B. Atmospheric Pressure (psia) = Local uncorrected
barometric reading (inches of mercury x .4912)
C. Gas Blanket Pressure (psi) (usually of small magnitude
and can be ignored in NPIP calculations)
Negative
D. Vapor Pressure of Fluid (psia)
E. Friction in Piping (psi)
F. Acceleration Head (psi)
Additional information concerning these factors:
A. Supply Tank Elevation
The supply tank should be located at an elevation as high as
possible with relation to the pump suction, taking advantage
of the natural terrain. Since pipe friction is usually of a low
order, it is sometimes advantageous to disregard the
accepted rule to make the inlet line as short as possible and
increase line length in order to gain additional tank elevation.
Before locating the pump and supply tank, make calculations
to determine if an elevated tank with a long inlet line or a
tank at a lower elevation with a short inlet line provides
the greater NPIP.
B. Atmospheric Pressure
This is the true local uncorrected barometric pressure at
the altitude of pump location expressed in psia. Refer to
Figure 1. Note: Barometric pressure as reported by the
weather bureau is normally corrected to sea level
conditions. The uncorrected reading must be used.
C. Gas Blanket Pressure
A gas blanket on the supply tank adds additional positive
pressure to the inlet system. Furthermore, a gas blanket of
a few ounces prevents absorption of oxygen by the water
and reduces corrosion in the pumps and piping.
D. Vapor Pressure
This is the absolute pressure at which the liquid will change
to vapor at a given temperature. Vapor pressure becomes
most critical when pumping fluid hydrocarbons; e.g.,
propane, crude oil, butane, L.N.G., etc., or water at elevated
temperatures. Table on page 5 reflects the vapor
pressure/temperature relationship of water.
E. Friction in Piping
The inlet line should be as short as practical with a minimum
of bends and fittings. A single inlet line between pump and
tank or header should be adequate for most installations.
When more than one pump is drawing from the same tank,
it is best to run individual inlet lines from each pump to the
tank. If bends or elbows are necessary in the line, they
should be of long radius.
F. Acceleration Pressure
This is the theoretical inertia effect of the fluid mass in the
inlet line and is probably the least understood factor affecting
pump performance. In effect, it is the pressure necessary
to accelerate the fluid at the beginning of each plunger stroke.
The acceleration pressure may be quite large in high speed
reciprocating pumps with long inlet lines. It is a function of
the volume of fluid in the inlet line, the pump speed, number
of plungers, and pump displacement. The pressure required
to accelerate cold water without cavitation may be calculated
with the formula:

Pac = KNLQ
D s2
Where:
Pac = Acceleration Pressure (psia)
Factor for type of pump Duplex Double Acting Pump
K = .000451
Triplex Single Acting Pump
K = .000259
Quintuplex Single Acting Pump
K = .000157
N = Pump Speed (rpm) L = Inlet Line Length (Ft.)
Q = Pump Discharge (gpm)
Ds =Inlet Line Diameter (inches)
From the above calculation it will be readily seen that large
diameter inlet pipe is important. Tests have demonstrated
that the acceleration pressure requirement can be practically
canceled by locating a suction stabilizer in the inlet line as
close as possible to the pump intake. Therefore, the use of
suction stabilizers on each pump is strongly recommended.
Typical Inlet System (Open Type)
Where:
NPIP Required (Net Positive Inlet Pressure) = That absolute
pressure in psia, above vapor pressure, as determined by
test, required to fill the pump cylinders sufficiently so that no
more than a 3% drop in capacity from maximum is achieved
(15.0 psia assumed in these examples).
NPIP Available = That pressure in psia of liquid being
pumped existing at the pump inlet.
Pa = Atmospheric pressure in psia due to altitude.
(Three elevations - 0, 3000 and 5000 feet are
used in our examples).
Pv = Vapor pressure in psia of liquid being pumped.
(1.7 psia in these examples).
Pf = Pressure drop in psi caused by friction in piping
and fittings. (.1 psi in these examples).
H = Height of liquid above pump inlet measured in feet.
P1 = Pressure in psig at pump inlet.
P2 = Pressure in psig at tank outlet.
To determine H (minimum height of liquid above pump inlet)
solve the following:
H(ft) = (NPIP Reqd. + Pv + Pf - Pa) x 2.3
P2(psig) = H x .443
P1(psig) = P2 - Pf or P1(psia) = P1(psig)+ Pa(psia)
It will be seen that as the barometric pressure decreases, the
level in the supply tank must be increased to provide the
same absolute NPIP at the pump inlet. If the vapor pressure
or pressure loss increase, the supply tank level must be
increased proportionally to maintain the NPIP required.
The above calculations provide minimum NPIP; a good
operating practice is to provide an additional 5 to 10 feet
of head for contingencies.
Calculation of Inlet System
To provide sufficient Net Positive Inlet Pressure (NPIP) it is
necessary to determine the minimum height of liquid
required in the supply tank. The interrelationship of vapor
pressure of the liquid being pumped, the atmospheric pressure and the liquid level above the pump inlet is shown in
the examples (Fig. 3).

Low Inlet Pressure


Where sufficient NPIP is not available, increased inlet
pressure may be obtained by the use of an inlet charging
centrifugal pump. Total horsepower requirements are not
increased by the use of the charging pump as the power
input to he main pump will be reduced by the power
requirement of the charging pump.
High Inlet Pressure
In single acting pumps high inlet pressure actually increases
the bearing loads and for this reason correction must be
made to plunger size selection if the inlet pressure is more
than 5% of the discharge pressure. For triplex pumps the
plunger size should be determined in the basis of an artificial
discharge pressure (Px) equal to the actual Discharge
pressure (Pd) plus one-half the actual inlet pressure (Pi).
Px=Pd+1/z Pi (for single acting triplex pumps)

Recommended Auxiliary Equipment


Suction Stabilizer
As previously pointed out the use of a suction stabilizer on
each pump is recommended.
A simple vertical chamber with a closed top, water level
gauge and air charging connection will perform satisfactorily
as a suction stabilizer if properly pressurized with an air or
gas cushion on top of the fluid.
Water absorbs air and gasses; therefore, this type of chamber
requires regular attention. Commercial stabilizers, equipped
with a rubber diaphragm separating the air from the fluid, are
available and can be charged to a predetermined pressure
with air or nitrogen. This charge will normally be retained for
a long period of time.

For quintuplex pumps the artificial pressure should be the


actual discharge pressure plus two-thirds the actual inlet
pressure. Px = Pd + 2/3 Pi (for single acting quintuplex pumps)

Discharge Pulsation Dampeners


A pulsation dampener should be installed on each pump as
close to the fluid end as possible.

The work performed by the pump, however, is calculated in


the usual manner using the actual discharge pressure less
the pump inlet pressure.

All positive displacement reciprocating pumps discharge


fluid in a pulsating manner. The harmonic relationship
between the pump speed, the piping system and other
pumps in the system may cause pulsations to be amplified
and result in transient pressure peaks far in excess of the
average discharge pressure. These peaks are not always
obvious and seldom will be indicated on pressure gauges.

Inlet and Discharge Piping


Inlet Piping Line
The line from the supply tank to the pump should be as
short and direct as practical and of sufficient diameter to
limit the fluid velocity to 1 to 2 feet/second. It should be free
of any restrictions and all fittings should be full opening type
with low resistance to the fluid flow.
Discharge Piping Line
The discharge line must not be smaller than the discharge
connection at the pump; it should be of a diameter sufficient
to permit a maximum fluid velocity of not more than 12
feet/second. This line should be streamlined through gradual
turns with friction not greater than those caused by 45 deg.
long radius elbows. Do not install any bend directly adjacent
to the pump discharge.

The pump may sound satisfactory with little or no audible


fluid knock but, such pressure peaks subject the pump and
piping system to excessively high stresses. Many tests have
shown that a pulsation dampener minimizes these pressure
peaks and contributes to longer pump and valve life.
The need for pulsation dampeners is increased where
multiple pump installations are involved. When two or more
pumps are discharging into a common header, the normal
pressure peaks of each pump may occur simultaneously
with the result that the pressure peaks for the system will
be considerably higher than for a single pump.

Safety Devices
By-Pass Line
A by-pass valve and by-pass return line to the supply tank
(not inlet line) are recommended for all installations. This will
permit loadless starting and facilitate checking the pump
and prime mover.
Relief Valves
A relief valve must be mounted on the discharge line as
close to the pump as possible. No other valve should be
interposed between the pump and relief valve. The relief
valve must have adequate relieving capacity and be set no
higher than 1.25 times the rated plunger working pressure.
Relief discharge should be piped back to the supply tank
(not the inlet line).
Caution:
Be certain that all pipe, pipe fittings, hose, etc., in the discharge line
have working pressure ratings equal to or greater than the maximum
pressure rating of the pump fluid end.
Warning:
Provide a means to prevent materials that may have been introduced
into the discharge system (rubber balls, steel balls, etc.) from entering
the discharge manifold on the pump or blocking the entrance to the
pressure relief valve.

Low Fluid Level Controls


Low fluid level shut-down controls should be provided on
all installations to protect the pump from operations with
insufficient fluid to fill the pump. Operations under starved
suction conditions will result in severe knocking and high
shock pressures within the fluid end. The low fluid level sensor
should be located on the tank to assure the minimum NPIP
at the pump inlet as described in Calculation on Inlet
System on the previous page.
Low Oil Pressure
Low Oil Pressure or low oil level shut-down is strongly
recommended to safeguard the pump power end against
lubrication failure.
Low Discharge Pressure Shut-down
Low Discharge Pressure Shut-down is recommended as
a protection against property damage due to discharge
line failure.
High Discharge Pressure Shut-down
High Discharge Pressure Shut-down is recommended as
extra insurance against pump damage in the event of relief
valve malfunction.

National-Oilwell Pump Nomenclature


100 T 4 L
Rated Input Horsepower
Single-Acting Plunger Type

Fluid End Pressure Ratings

Simplex

XL

Duplex

Extra Low Pressure


Low Pressure

Triplex

LS

Low Pressure Special Rating

Quintuplex

Medium Pressure

MS Medium Pressure Special Rating


H

Nominal Stroke Length

High Pressure

Quick Reference Pump Selection


Single-Acting, Continuous Duty Pumps
Pump Model No.
Rated
Horsepower
2

11

22

30
31
32*

55

59

60

80

100

100

103

110

125

130

133

163

165

184

200

202

NEW

OLD

2S-1L
2S-1M
2S-1H
5S-2L
5S-2M
5S-2H
11D-2L
11D-2M
11D-2H
22T-2L
22T-2M
22T-2H
30T-2L
30T-2H
31Q-2L
32T-2L
32T-2M
32T-2H
55T-3L
55T-3SC
55T-3LS
55T-3M
55T-3MS
55T-3H
59T-3L
59T-3M
59T-3MS
59T-3H
60T-3L
60T-3M
60T-3H
80T-3L
80T-3M
80T-3H
100T-4L
100T-4M
100T-4H
101T-4L
101T-4M
101T-4H
103Q-3L
103Q-3M
103Q-3MS
103Q-3H
110Q-3L
110Q-3M
110Q-3MS
110Q-3H
125T-4L
125T-4M
125T-4H
130T-4L
130T-4M
130T-4H
133T-4L
133T-4M
133T-4H
163Q-4L
163Q-4M
163Q-4H
165T-5L
165T-5M
165T-5H
184T-7XL
184T-7L
184T-7M
184T-7H
200T-5L
200T-5M
200T-5H
202T-6L
202T-6M

P50BLS
P50B
P50BH
P50ALS
P50A
P50H
P100ALS
P100A
P100H
T225LS
T225M
T225H
J-30-L
J-30-H
5P200A
T225LS
T225M
T225H
3364-7
3365-5SC
3364-6
3364-3
3364-2
3364-1
T365AL
T365AM
T365MS
T365H
J-60-L
J-60-M
J-60-H
80T-3L
80T-3M
80T-3H
J-100-L
J-100-M
J-100-H
T100-4
T100-3
T100-2
Q3115AL
Q3115AM
Q3115MS
Q3115H
HP125AL
HP125AM
HP125MS
HP125H
A344-H
A334-H
A324-H
130T-4L
130T-4M
130T-4H
T140-4
T140-3
T140-2
HP165AL
HP165AM
HP165MS
J-165-L
J-165-M
J-165-H
HP250XL
HP250BL
HP250BM
HP250BH
J-200-L
J-200-M
J-200-H
A346-H
A336-H

Gallons Per
Minute
(USGPM)
4.80
3.60
1.20
10.41
7.97
2.60
23.80
18.24
5.96
42.70
32.70
10.70
51.65
22.95
57.40
42.69
32.68
10.67
95.62
77.46
95.62
46.86
46.86
23.91
134.90
93.71
33.74
14.99
137.7
61.2
28.95
174.3
61.2
28.9
209.1
82.9
56.2
209.1
114.7
48.5
232.9
161.8
58.2
25.9
235.6
163.6
58.9
26.2
293.8
165.2
92.9
241.3
103.6
56.2
209.1
114.7
48.5
339.8
186.5
78.8
326.4
154.3
81.6
636.7
347.9
203.4
87.0
326.4
154.3
81.6
353.7
176.3

Maximum Displacement
Liters / Sec Barrels Per Day Cubic Meters
(l/s)
(BPD)
Per Hour
(m3/hr)
0.30
164
1.08
0.23
125
0.83
0.08
41
0.27
0.66
357
2.36
0.50
274
1.81
0.16
90
0.59
1.50
816
5.40
1.15
626
4.14
0.38
205
1.35
2.69
1,464
9.69
2.06
1,121
7.42
0.67
366
2.42
3.26
1,771
11.73
1.45
787
5.21
3.62
1,968
13.04
2.69
1,464
9.69
2.06
1,121
7.42
0.67
366
2.42
6.03
3,279
21.72
4.89
2,656
17.59
6.03
3,279
21.72
2.96
1,607
10.64
2.96
1,607
10.64
1.51
820
5.43
8.51
4,627
30.65
5.91
3,213
21.28
2.13
1,157
7.66
0.95
515
3.41
8.69
4,722
31.27
3.86
2,099
13.90
1.82
992
6.57
11.00
5,976
39.58
3.86
2,099
13.90
1.82
992
6.57
13.19
7,171
47.49
5.23
2,843
18.83
3.55
1,928
12.77
13.2
7,171
47.5
7.2
3,935
26.1
3.1
1,663
11.0
14.70
7,987
52.9
10.21
5,547
36.7
3.67
1,997
13.2
1.63
888
5.9
14.9
8,079
53.5
10.3
5,610
37.2
3.7
2,020
13.4
1.7
898
5.9
18.5
10,072
66.7
10.4
5,666
37.5
5.9
3,187
21.1
15.2
8,272
54.8
6.5
3,551
23.5
3.5
1,928
12.8
13.2
7,171
47.5
7.2
3,935
26.1
3.1
1,663
11.0
21.4
11,652
77.2
11.8
6,394
42.3
5.0
2,702
17.9
20.6
11,191
74.1
9.7
5,290
35.0
5.1
2,798
18.5
40.2
21,832
144.6
21.9
11,927
79.0
12.8
6,975
46.2
5.5
2,982
19.7
20.6
11,191
74.1
9.7
5,290
35.0
5.1
2,798
18.5
22.3
12,127
80.3
11.1
6,045
40.0

Maximum Pressure
Pounds Per
Kilopascals
Square Inch
(kPa)
(psi)
1,149
7,920
2,042
14,081
4,595
31,681
1,149
7,920
2,042
14,081
4,595
31,681
1,149
7,920
2,042
14,081
4,595
31,681
1,443
9,949
2,565
17,688
4,660
32,130
2,000
13,790
5,000
34,474
2,042
14,081
2,037
14,046
2,050
14,134
4,600
31,716
1,391
9,591
1,817
12,527
1,480
10,204
3,561
24,552
2,473
17,050
3,300
22,753
970
6,686
2,295
15,825
4,789
33,017
10,000
68,948
1,500
10,342
3,200
22,063
5,000
34,474
2,017
13,906
4,267
29,420
5,161
35,584
1,659
11,436
3,180
21,925
5,000
34,474
1,220
8,408
2,744
18,919
5,378
37,081
970
6,686
2,295
15,825
4,789
33,017
10,000
68,948
1,037
7,149
2,454
16,922
5,121
35,306
10,000
68,948
1,500
10,342
3,180
21,925
5,000
34,474
1,750
12,065
3,111
21,450
5,000
34,474
1,440
9,929
3,600
24,821
6,000
41,369
1,220
8,408
2,744
18,919
5,378
37,081
1,650
11,376
3,120
21,512
5,000
34,474
728
5,020
1,204
8,299
2,912
20,081
6,000
41,369
1,680
11,583
3,349
23,097
5,000
34,474
1,500
10,342
3,180
21,925

Type

Simplex

Simplex

Duplex

Triplex

Triplex
Quintuplex
Triplex

Triplex

Triplex

Triplex

Triplex

Triplex

Triplex

Quintuplex

Quintuplex

Triplex

Triplex

Triplex

Quintuplex

Triplex

Triplex

Triplex

Triplex

Single-Acting, Continuous Duty Pumps (continued)


Pump Model No.
Rated
Horsepower
217

250

267
300

308

350

430

543

622

625

750
1069

NEW

OLD

217Q-4L
217Q-4M
217Q-4H
250T-5L
250T-5M
250T-5H
267Q-6L
267Q-6M
300Q-5L
300Q-5M
300Q-5H
308T-7XL
308T-7L
308T-7M
308T-7H
350Q-5L
350Q-5M
350Q-5H
430T-7L
430T-7M
430T-7H
543Q-7XL
543Q-7L
543Q-7M
543Q-7H
622T-8XL
622T-8L
622T-8M
622T-8MS
625Q-7L
625Q-7M
625Q-7H
D-750L
C-1000

HP200AL
HP200AM
HP200MS
250T-5L
250T-5M
250T-5H
A-546
A-536
J-275-L
J-275-M
J-275-H
HP360XL
HP360AL
HP360AM
HP360H
Q350-4
Q350-3
Q350-2

HP600XL
HP600AL
HP600AM
HP600H
T600-7
T600-5
T600-4
T600-3
J-625-L
J-625-M
J-625-H
D-750L
C-1000

Gallons Per
Minute
(USGPM)
339.8
186.5
78.8
368.5
215.5
103.3
663.3
330.5
544.0
257.1
136.0
636.7
347.9
203.4
87.0
489.6
323.2
154.9
535.5
301.2
192.8
1121.3
612.6
358.2
153.1
1039.6
530.4
339.5
190.9
850.8
544.5
306.3
560
929

Maximum Displacement
Liters / Sec Barrels Per Day Cubic Meters
(l/s)
(BPD)
Per hour
(m3/hr)
21.4
11,652
77.2
11.8
6,394
42.3
5.0
2,702
17.9
23.2
12,634
83.7
13.6
7,388
48.9
6.5
3,541
23.5
41.8
22,741
150.7
20.9
11,331
75.1
34.3
18,651
123.6
16.2
8,816
58.4
8.6
4,663
30.9
40.2
21,832
144.6
21.9
11,927
79.0
12.8
6,975
46.2
5.5
2,982
19.7
30.9
16,787
111.2
20.4
11,082
73.4
9.8
5,312
35.2
33.8
18,360
121.6
19.0
10,328
68.4
12.2
6,610
43.8
70.7
38,445
254.6
38.6
21,003
139.1
22.6
12,283
81.4
9.7
5,251
34.8
65.6
35,643
236.1
33.5
18,186
120.5
21.4
11,639
77.1
12.0
6,547
43.4
53.7
29,172
193.2
34.4
18,671
123.7
19.3
10,502
69.6
35.3
19,200
127.2
58.6
31,851
211.0

Maximum Pressure
Pounds Per
Kilopascals
Square Inch
(kPa)
(psi)
1,440
9,929
3,600
24,821
6,000
41,369
1,544
10,646
3,026
20,865
5,000
34,474
1,420
9,791
3,180
21,925
1,650
11,376
3,000
20,684
5,000
34,474
1,220
8,410
2,169
14,952
3,600
24,821
8,000
55,158
1,670
11,511
3,483
24,017
6,000
41,369
1,550
10,687
3,150
21,719
5,000
34,474
1,220
8,410
2,169
14,952
3,600
24,821
8,000
55,158
1,640
11,307
2,502
17,254
4,279
29,505
7,232
49,863
1,550
10,686
3,150
21,719
5,000
34,474
5,000
34,474
3,705
25,545

Type

Quintuplex

Triplex

Quintuplex
Quintuplex

Triplex

Quintuplex

Triplex

Quintuplex

Triplex

Quintuplex

Triplex - Piston
Triplex

Double-Acting, Continuous Duty Piston Pumps


Rated
Horsepower
12
33
74
104
127
130
250
258

Pump
Model
No.
535
545
1847-A
1550
1654
1757
1759
2651
2652

Gallons Per
Minute
(USGPM)
69.6
117
160
281.7
233.8
336.8
637.2
391.9
702.3

Maximum Displacement
Liters / Sec
Barrels Per Day
(l/s)
(BPD)
4.4
7.4
10.1
17.8
14.7
21.2
40.2
24.7
44.3

2,387
4,012
5,487
9,658
8,016
11,547
21,849
13,434
24,079

Cubic Meters
Per Hour
(m3/hr)
15.8
26.6
36.3
64.0
53.1
76.5
144.7
89.0
159.5

Maximum Pressure
Pounds Per
Kilopascals
Square Inch
(kPa)
(psi)
796
5,487
509
3,509
990
6,826
1,440
9,929
1,800
12,411
1,750
12,066
1,042
7,184
1,760
12,135
1,125
7,757

Type

Duplex
Duplex
Duplex
Duplex
Duplex
Duplex
Duplex
Duplex

Single-Acting, Intermittent Duty Pumps (1)


Rated
Horsepower
185
340
350
400
500
600
1300
2250

Pump
Model
No.
JWS-185
JWS-340
W-350
JWS-400
W-500
W-600-S
W-1300
W-2250

Maximum Displacement at Minimum Pressure


Gallons Per
Liters / Sec
Minimum
Minute
(l/s)
Pressure
(USGPM)
PSI (kPa)
367
23.2
780 (5378)
367
23.2
1,430 (9860)
689
43.5
741 (5109)
618
39.0
1,004 (6923)
689
43.5
1,058 (7295)
558
35.2
1,660 (11445)
1,515
95.6
1,250 (8619)
1,515
95.6
2,164 (14920)

Maximum Displacement at Maximum Pressure


Gallons Per
Liters / Sec
Maximum
Minute
(l/s)
Pressure
(USGPM)
PSI (kPa)
20
1.3
10000 (68,950)
39
2.5
10000 (68,950)
12
.8
25451 (175,485)
63
4.0
10000 (68,950)
16
1.0
25096 (173,037)
19
1.2
20372 (140,460)
115
7.3
165121 (113,850)
131
8.3
19894 (137,164)

Type

Piston or Plunger
Piston or Plunger
Plunger
Piston or Plunger
Plunger
Plunger
Plunger
Plunger

(1) Applications at pressures above 15,000 PSIG must be approved by National Oilwell Engineering Department
The maximum displacement (volume) values listed assume 100% volumetric efficiency. Actual "in service" displacement (volume) will vary depending on the inlet piping and the fluid being pumped.
The rated horsepower listed includes allowances for mechanical efficiencies and is the maximum horsepower allowed for the pump model.
An auxiliary lubrication system may be required for operating speeds below 200 RPM. Please consult your Sales and Service location for details.
Pumps will not produce the maximum displacement listed at the maximum pressure listed. Consult our Sales & Service location for details.

2S-1 Simplex Plunger Pump


Specifications
7.13

6.50
C
3.25

8.44

.75
TYP
3 PLACES
1.500
1.499

.375 x .188 KEYWAY


2.813 LONG

7.03

F
A

B
7.06

Pump Size:
maximum plunger size x stroke length, in.(mm)
2.000 x 1.000 (50.8 x 25.4)
Rated BPH (kW) at 350 RPM
2.5 (1.9)
Rated plunger load, pounds (kg)
2030 (921)
Maximum discharge pressure: psi (kPa)
L model: 1149 (7920)
M model: 2042 (14081)
H model: 4595 (31681)
Crankshaft extension:
Diameter, in.(mm): 1.500 (38.1)
Length, in.(mm): 3.375 (85.73)
Keyway width x depth, in.(mm):
3/8 x 3/16 (9.53 x 4.76)
Maximum recommended sheave diameter,
in.(mm): 25 (635)
For larger sizes: Contact Customer Service
Oil Capacity, gallons (L)
Crankcase: 1/2 (1.89)
Weight, pump only on
wood shipping skids, pounds (kg): 219 (99)
Weight varies with pump model
Standard Materials for Fluid Ends:
L & M models
Cast Ductile Iron, Cast 316 Stainless Steel
Cast Nickel-Aluminum-Bronze
Plate Carbon Steel
H model
Forged/Plate Carbon Steel
Forged 15-5 Stainless Steel

.63
11.88
2.75
5.75

13.75
D
E

Pump Model
2S-1L
2S-1M
2S-1H

Flange Connections
Discharge Connection Sizes Suction Connection Sizes
1 (25.4)-11 1/2 FNPT
2 (50.8)-11 1/2 FNPT
1 (25.4)-11 1/2 FNPT
2 (50.8)-11 1/2 FNPT
3/4 (19.05)-14 NPT
1 1/4 (31.75)-11 1/2 THDS

A
3 1/8
3 1/8
3 3/4

Dimensions (Inches)
B
C
D
E
4 7/8
3 1/2
20 3/8
29 9/16
4 7/8
3 1/2
20 3/8
29 9/16
4 1/4
5 1/2
20
31 5/16

F
5 15/16
5 15/16
7 1/8

2S-1 Simplex Plunger Pump


Performance Data
PUMP

2S-1L
(P50BLS)

2S-1M
(P50B)

2S-1H

PUMP

2S-1L
(P50BLS)

2S-1M
(P50B)

2S-1H

English Units
Plunger
Plunger
BPD
Dia.
Area
per
In.
Sq. In.
RPM
2.000
3.1416
0.4663
1.875
2.7612
0.4098
1.750
2.4053
0.3570
1.625
2.0739
0.3078
1.500
1.7671
0.2623
1.750
2.4053
0.3570
1.625
2.0739
0.3078
1.500
1.7671
0.2623
1.375
1.4849
0.2204
1.250
1.2272
0.1821
1.125
0.9940
0.1475
1.000
0.7854
0.1166
0.875
0.6013
0.0892
0.750
0.4418
0.0656
Brake Horsepower Required

GPM
per
RPM
0.0136
0.0120
0.0104
0.0090
0.0076
0.0104
0.0090
0.0076
0.0064
0.0053
0.0043
0.0034
0.0026
0.0019

Metric Units
Plunger
Plunger
Dia.
Area
mm
cm2
51
20.268
48
17.814
44
15.518
41
13.380
38
11.401
44
15.518
41
13.380
38
11.401
35
9.580
32
7.917
29
6.413
25
5.067
22
3.879
19
2.850
Kilowatts Required

L/Sec.
per
RPM
0.0009
0.0008
0.0007
0.0006
0.0005
0.0007
0.0006
0.0005
0.0004
0.0003
0.0003
0.0002
0.0002
0.0001

M3/Hr
per
RPM
0.0031
0.0027
0.0024
0.0020
0.0017
0.0024
0.0020
0.0017
0.0015
0.0012
0.0010
0.0008
0.0006
0.0004

50 RPM
Max.
Press.
PSI
646
735
844
979
1149
844
979
1149
1367
1654
2042
2585
3376
4595

BPD
24
21
18
16
14
18
16
14
12
10
8
6
5
4

GPM
0.7
0.6
0.5
0.4
0.4
0.5
0.4
0.4
0.3
0.3
0.2
0.2
0.1
0.1
0.4

150 RPM

BPD
70
62
54
47
40
54
47
40
34
28
23
18
14
10

200 RPM

GPM
2.0
1.8
1.6
1.3
1.1
1.6
1.3
1.1
1.0
0.8
0.6
0.5
0.4
0.3
1.1

BPD
94
82
72
62
53
72
62
53
45
37
30
24
18
14

GPM
2.7
2.4
2.1
1.8
1.5
2.1
1.8
1.5
1.3
1.1
0.9
0.7
0.5
0.4

250 RPM

BPD
117
103
90
77
66
90
77
66
56
46
37
30
23
17

2.0

50 RPM
150 RPM
Max.
Press.
kPa M3/Hr L/Sec. M3/Hr L/Sec.
4455
0.15
0.04
0.46
0.13
5069
0.14
0.04
0.41
0.11
5819
0.12
0.03
0.35
0.10
6749
0.10
0.03
0.31
0.08
7920
0.09
0.02
0.26
0.07
5819
0.12
0.03
0.35
0.10
6749
0.10
0.03
0.31
0.08
7920
0.09
0.02
0.26
0.07
9426
0.07
0.02
0.22
0.06
11405 0.06
0.02
0.18
0.05
14081 0.05
0.01
0.15
0.04
17821 0.04
0.01
0.12
0.03
23276 0.03
0.01
0.09
0.02
31681 0.02
0.01
0.07
0.02
0.3
0.8

200 RPM

M3/Hr
0.62
0.54
0.47
0.41
0.35
0.47
0.41
0.35
0.29
0.24
0.20
0.15
0.12
0.09

L/Sec.
0.17
0.15
0.13
0.11
0.10
0.13
0.11
0.10
0.08
0.07
0.05
0.04
0.03
0.02
1.5

GPM
3.4
3.0
2.6
2.2
1.9
2.6
2.2
1.9
1.6
1.3
1.1
0.8
0.7
0.5
1.8

250 RPM

M3/Hr
0.77
0.68
0.59
0.51
0.43
0.59
0.51
0.43
0.36
0.30
0.24
0.19
0.15
0.11

300 RPM

BPD
140
123
108
93
79
108
93
79
67
55
45
35
27
20

GPM
4.1
3.6
3.1
2.7
2.3
3.1
2.7
2.3
1.9
1.6
1.3
1.0
0.8
0.6

350 RPM

BPD
164
144
125
108
92
125
108
92
78
64
52
41
32
23

GPM
4.8
4.2
3.6
3.1
2.7
3.6
3.1
2.7
2.2
1.9
1.5
1.2
0.9
0.7

2.1

2.5

300 RPM

350 RPM

L/Sec. M3/Hr L/Sec. M3/Hr L/Sec.


0.21
0.93
0.26
1.08
0.30
0.19
0.81
0.23
0.95
0.26
0.16
0.71
0.20
0.83
0.23
0.14
0.61
0.17
0.71
0.20
0.12
0.52
0.14
0.61
0.17
0.16
0.71
0.20
0.83
0.23
0.14
0.61
0.17
0.71
0.20
0.12
0.52
0.14
0.61
0.17
0.10
0.44
0.12
0.51
0.14
0.08
0.36
0.10
0.42
0.12
0.07
0.29
0.08
0.34
0.10
0.05
0.23
0.06
0.27
0.08
0.04
0.18
0.05
0.21
0.06
0.03
0.13
0.04
0.15
0.04
1.3
1.6
1.9

Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on 72% Mechanical Efficiency.
The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own
evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that
stipulated in National Oilwell Standard Terms and Conditions of Sale.

Authorized Distributor:

www.natoil.com / customer.service@natoil.com
10000 Richmond, Houston, Texas 77042
(713)346-7500 (phone) (713)346-7366 (fax)

5S-2 Simplex Plunger Pump


Specifications
7.13

6.50
C

3.25

8.44
.75
TYP
3 PLACES
1.500
1.499

.38 X .18 X 2.81


LG KEYWAY
"5S-2H" ONLY

7.03

7.06

.63
11.88
2.75
5.75

13.75
D

D
E

Pump Model
5S-2L
5S-2M
5S-2H

Flange Connections
Discharge Connection Sizes Suction Connection Sizes
1 (25.4)-11 1/2 FNPT
2 (50.8)-11 1/2 FNPT
1 (25.4)-11 1/2 FNPT
2 (50.8)-11 1/2 FNPT
3/4 (19.05)-14 NPT
1 1/4 (31.75)-11 1/2 THDS

A
3 1/8
3 1/8
3 3/4

Pump Size:
maximum plunger size x stroke length, in.(mm)
2.000 x 2.188 (50.8 x 55.56)
Rated BHP (kW) at 350 RPM
5.5 (4.1)
Rated plunger load, pounds (kg)
2030 (921)
Maximum discharge pressure: psi (kPa)
L model: 1149 (7920)
M model: 2042 (14081)
H model: 4595 (31681)
Crankshaft extension: in.(mm)
Diameter, in.(mm): 1.500 (38.1)
Length, in.(mm): 3.375 (85.73)
Keyway width x depth, in.(mm):
3/8 x 3/16 (9.53 x 4.76)
Maximum recommended sheave diameter,
in.(mm): 25 (635)
For larger sizes: Contact Factory
Oil Capacity, gallons (L)
Crankcase: 1/2 (1.89)
Weight, pump only on
wood shipping skids, pounds (kg): 218 (99.1)
Weight varies with pump model
Standard Materials for Fluid Ends:
L & M models
Cast Ductile Iron
Cast Nickel-Aluminum-Bronze
Cast 316 Stainless Steel
Plate Carbon Steel
H model
Forged Carbon Steel
Forged 15-5 Stainless Steel

Dimensions (Inches)
B
C
D
E
4 7/8
3 1/2
20 3/8
29 9/16
4 7/8
3 1/2
20 3/8
29 9/16
4 1/4
5 1/2
20
31 5/16

F
5 15/16
5 15/16
7 1/8

5S-2 Simplex Plunger Pump


Performance Data
PUMP

5S-2L
(P50ALS)

5S-2M
(P50A)

5S-2H
(P50H)

PUMP

5S-2L
(P50ALS)

5S-2M
(P50A)

5S-2H
(P50H)

English Units
Plunger
Plunger
BPD
Dia.
Area
per
In.
Sq. In.
RPM
2.000
3.1416
1.0200
1.875
2.7612
0.8965
1.750
2.4053
0.7809
1.625
2.0739
0.6734
1.500
1.7671
0.5737
1.750
2.4053
0.7809
1.625
2.0739
0.6734
1.500
1.7671
0.5737
1.375
1.4849
0.4821
1.250
1.2272
0.3984
1.125
0.9940
0.3227
1.000
0.7854
0.2550
0.875
0.6013
0.1952
0.750
0.4418
0.1434
Brake Horsepower Required

GPM
per
RPM
0.0297
0.0261
0.0228
0.0196
0.0167
0.0228
0.0196
0.0167
0.0141
0.0116
0.0094
0.0074
0.0057
0.0042

Metric Units
Plunger
Plunger
Dia.
Area
mm
cm2
51
20.268
48
17.814
44
15.518
41
13.380
38
11.401
44
15.518
41
13.380
38
11.401
35
9.580
32
7.917
29
6.413
25
5.067
22
3.879
19
2.850
Kilowatts Required

L/Sec.
per
RPM
0.0019
0.0016
0.0014
0.0012
0.0011
0.0014
0.0012
0.0011
0.0009
0.0007
0.0006
0.0005
0.0004
0.0003

M3/Hr
per
RPM
0.0068
0.0059
0.0052
0.0045
0.0038
0.0052
0.0045
0.0038
0.0032
0.0026
0.0021
0.0017
0.0013
0.0010

50 RPM
Max.
Press.
PSI
646
735
844
979
1149
844
979
1149
1367
1654
2042
2585
3376
4595

BPD
51
45
40
34
29
40
34
29
25
20
17
13
10
8

GPM
1.49
1.31
1.14
0.98
0.84
1.14
0.98
0.84
0.70
0.58
0.47
0.37
0.28
0.21
0.8

150 RPM

BPD
153
135
118
102
87
118
102
87
73
60
49
39
30
22

200 RPM

GPM
4.46
3.92
3.42
2.95
2.51
3.42
2.95
2.51
2.11
1.74
1.41
1.12
0.85
0.63
2.3

BPD
204
180
157
135
115
157
135
115
97
80
65
51
40
29

250 RPM

GPM
5.95
5.23
4.56
3.93
3.35
4.56
3.93
3.35
2.81
2.32
1.88
1.49
1.14
0.84

BPD
255
225
196
169
144
196
169
144
121
100
81
64
49
36

4.0

50 RPM
150 RPM
Max.
Press.
kPa M3/Hr L/Sec. M3/Hr L/Sec.
4455
0.34
0.09
1.01
0.28
5069
0.30
0.08
0.89
0.25
5819
0.26
0.07
0.78
0.22
6749
0.22
0.06
0.67
0.19
7920
0.19
0.05
0.57
0.16
5819
0.26
0.07
0.78
0.22
6749
0.22
0.06
0.67
0.19
7920
0.19
0.05
0.57
0.16
9426
0.16
0.04
0.48
0.13
11405 0.13
0.04
0.40
0.11
14081 0.11
0.03
0.32
0.09
17821 0.08
0.02
0.25
0.07
23276 0.06
0.02
0.19
0.05
31681 0.05
0.01
0.14
0.04
0.6
1.7

200 RPM

M3/Hr
1.35
1.19
1.03
0.89
0.76
1.03
0.89
0.76
0.64
0.53
0.43
0.34
0.26
0.19

L/Sec.
0.38
0.33
0.29
0.25
0.21
0.29
0.25
0.21
0.18
0.15
0.12
0.09
0.07
0.05
3.0

GPM
7.44
6.54
5.69
4.91
4.18
5.69
4.91
4.18
3.52
2.91
2.35
1.86
1.42
1.05
3.9

250 RPM

M3/Hr
1.69
1.48
1.29
1.12
0.95
1.29
1.12
0.95
0.80
0.66
0.53
0.42
0.32
0.24

300 RPM

BPD
306
269
235
203
173
235
203
173
145
120
97
77
59
44

GPM
8.92
7.84
6.83
5.89
5.02
6.83
5.89
5.02
4.22
3.49
2.82
2.23
1.71
1.26

350 RPM

BPD
357
314
274
236
201
274
236
201
169
140
113
90
69
51

GPM
10.41
9.15
7.97
6.87
5.86
7.97
6.87
5.86
4.92
4.07
3.29
2.60
1.99
1.46

4.7

5.5

300 RPM

350 RPM

L/Sec. M3/Hr L/Sec. M3/Hr L/Sec.


0.47
2.03
0.56
2.36
0.66
0.41
1.78
0.49
2.08
0.58
0.36
1.55
0.43
1.81
0.50
0.31
1.34
0.37
1.56
0.43
0.26
1.14
0.32
1.33
0.37
0.36
1.55
0.43
1.81
0.50
0.31
1.34
0.37
1.56
0.43
0.26
1.14
0.32
1.33
0.37
0.22
0.96
0.27
1.12
0.31
0.18
0.79
0.22
0.92
0.26
0.15
0.64
0.18
0.75
0.21
0.12
0.51
0.14
0.59
0.16
0.09
0.39
0.11
0.45
0.13
0.07
0.29
0.08
0.33
0.09
2.9
3.5
4.1

Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on 72% Mechanical Efficiency.
The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own
evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that
stipulated in National Oilwell Standard Terms and Conditions of Sale.

Authorized Distributor:

www.natoil.com / customer.service@natoil.com
10000 Richmond, Houston, Texas 77042
(713)346-7500 (phone) (713)346-7366 (fax)

11D-2 Duplex Plunger Pump


Specifications
C/2
3.25
9.12

10.44

3.25

%%c
1.500^1.499;

.375 x .188 KEYWAYP2.000 LONG

DISCHARGEPCONNE
CTION

F5.9

.44
A
13.38
B
7.06

.63 TYP
SUCTIONPCONNECTI
ON
2.50

13.75

5.75

DP20.38

Pump Size:
maximum plunger size x stroke length, in.(mm)
2.000 x 2.188 (50.8 x 55.56)
Rated BHP (kW) at 400 RPM: 11 (8)
Rated plunger load, pounds (kg)
2030 (921)
Maximum discharge pressure: psi (kPa)
L model: 1149 (7920)
M model: 2042 (14081)
H model: 4595 (31681)
Crankshaft extension:
Diameter, in.(mm): 1.500 (38.1)
Length, in.(mm): 3.375 (85.73)
Keyway width x depth, in.(mm):
3/8 x 3/16 (9.53 x 4.76)
Maximum recommended sheave diameter,
in.(mm): 25 (635)
For larger sizes: Contact Factory
Oil Capacity, gallons (L)
Crankcase: 7/8 (3.31)
Weight, pump only on
wood shipping skids, pounds (kg)
L model: 305 (138)
M model: 305 (138)
H model: 350 (159)
Standard Materials for Fluid Ends:
L model
Cast Ductile Iron
Cast Nickel-Aluminum-Bronze
Forged 316 Stainless Steel
Forged/Plate Carbon Steel
M model
Cast Ductile Iron
Cast Nickel-Aluminum-Bronze
Forged 316 Stainless Steel
Forged/Plate Carbon Steel
H model
Forged 15-5 Stainless Steel

22.70PSUCTION & DISCHARGE

EP29.34

Pump Model
11D-2L
11D-2M
11D-2H

Flange Connections
Discharge Connection Sizes Suction Connection Sizes
1 (25.4)-11 1/2 NPT
2 (50.8)-11 1/2 NPT
1 (25.4)-11 1/2 NPT
2 (50.8)-11 1/2 NPT
3/4 (19.05)-14 NPT
1 1/4 (31.75)-11 1/2 NPT

A
3 1/8
3 1/8
3 3/4

Dimensions (Inches)
B
C
D
E
4 7/8
7 1/2
20 3/8
29 3/8
4 7/8
7 1/2
20 3/8
29 3/8
4 1/4
9 1/2
20
32 1/8

F
6
6
7 7/8

11D-2 Duplex Plunger Pump


Performance Data
PUMP

11D-2L
(P100ALS)

11D-2M
(P100A)

11D-2H
(P100H)

PUMP

11D-2L
(P100ALS)

11D-2M
(P100A)

11D-2H
(P100H)

English Units
Plunger
Plunger
BPD
Dia.
Area
per
In.
Sq. In.
RPM
2.000
3.1416
2.0400
1.875
2.7612
1.7930
1.750
2.4053
1.5619
1.625
2.0739
1.3467
1.500
1.7671
1.1475
1.750
2.4053
1.5619
1.625
2.0739
1.3467
1.500
1.7671
1.1475
1.375
1.4849
0.9642
1.250
1.2272
0.7969
1.125
0.9940
0.6455
1.000
0.7854
0.5100
0.875
0.6013
0.3905
0.750
0.4418
0.2869
Brake Horsepower Required

GPM
per
RPM
0.0595
0.0523
0.0456
0.0393
0.0335
0.0456
0.0393
0.0335
0.0281
0.0232
0.0188
0.0149
0.0114
0.0084

Metric Units
Plunger
Plunger
Dia.
Area
mm
cm2
51
20.268
48
17.814
44
15.518
41
13.380
38
11.401
44
15.518
41
13.380
38
11.401
35
9.580
32
7.917
29
6.413
25
5.067
22
3.879
19
2.850
Kilowatts Required

L/Sec.
per
RPM
0.0038
0.0033
0.0029
0.0025
0.0021
0.0029
0.0025
0.0021
0.0018
0.0015
0.0012
0.0009
0.0007
0.0005

M3/Hr
per
RPM
0.0135
0.0119
0.0103
0.0089
0.0076
0.0103
0.0089
0.0076
0.0064
0.0053
0.0043
0.0034
0.0026
0.0019

50 RPM
Max.
Press.
PSI
646
735
844
979
1149
844
979
1149
1367
1654
2042
2585
3376
4595

BPD
102
90
79
68
58
79
68
58
49
40
33
26
20
15

GPM
3.0
2.6
2.3
2.0
1.7
2.3
2.0
1.7
1.4
1.2
0.9
0.7
0.6
0.4
2

150 RPM

BPD
306
269
235
203
173
235
203
173
145
120
97
77
59
44

200 RPM

GPM
8.9
7.8
6.8
5.9
5.0
6.8
5.9
5.0
4.2
3.5
2.8
2.2
1.7
1.3

BPD
408
359
313
270
230
313
270
230
193
160
130
102
79
58

50 RPM
150 RPM
Max.
Press.
kPa M3/Hr L/Sec. M3/Hr L/Sec.
4455
0.68
0.19
2.03
0.56
5069
0.59
0.16
1.78
0.49
5819
0.52
0.14
1.55
0.43
6749
0.45
0.12
1.34
0.37
7920
0.38
0.11
1.14
0.32
5819
0.52
0.14
1.55
0.43
6749
0.45
0.12
1.34
0.37
7920
0.38
0.11
1.14
0.32
9426
0.32
0.09
0.96
0.27
11405 0.26
0.07
0.79
0.22
14081 0.21
0.06
0.64
0.18
17821 0.17
0.05
0.51
0.14
23276 0.13
0.04
0.39
0.11
31681 0.10
0.03
0.29
0.08
1
4

250 RPM

GPM
11.9
10.5
9.1
7.9
6.7
9.1
7.9
6.7
5.6
4.6
3.8
3.0
2.3
1.7

BPD
510
449
391
337
287
391
337
287
242
200
162
128
98
72

GPM
14.9
13.1
11.4
9.8
8.4
11.4
9.8
8.4
7.0
5.8
4.7
3.7
2.8
2.1

350 RPM

BPD
714
628
547
472
402
547
472
402
338
279
226
179
137
101

GPM
20.8
18.3
15.9
13.7
11.7
15.9
13.7
11.7
9.8
8.1
6.6
5.2
4.0
2.9

400 RPM

BPD
816
718
625
539
459
625
539
459
386
319
259
204
157
115

GPM
23.8
20.9
18.2
15.7
13.4
18.2
15.7
13.4
11.2
9.3
7.5
5.9
4.6
3.3

10

11

200 RPM

250 RPM

350 RPM

400 RPM

M3/Hr
2.70
2.38
2.07
1.78
1.52
2.07
1.78
1.52
1.28
1.06
0.86
0.68
0.52
0.38

L/Sec.
0.75
0.66
0.57
0.50
0.42
0.57
0.50
0.42
0.35
0.29
0.24
0.19
0.14
0.11

M3/Hr
3.38
2.97
2.59
2.23
1.90
2.59
2.23
1.90
1.60
1.32
1.07
0.84
0.65
0.48

L/Sec. M3/Hr
0.94
4.73
0.82
4.16
0.72
3.62
0.62
3.12
0.53
2.66
0.72
3.62
0.62
3.12
0.53
2.66
0.44
2.24
0.37
1.85
0.30
1.50
0.23
1.18
0.18
0.91
0.13
0.67
5

L/Sec. M3/Hr
1.31
5.40
1.15
4.75
1.01
4.14
0.87
3.57
0.74
3.04
1.01
4.14
0.87
3.57
0.74
3.04
0.62
2.55
0.51
2.11
0.42
1.71
0.33
1.35
0.25
1.03
0.18
0.76
7

L/Sec.
1.50
1.32
1.15
0.99
0.84
1.15
0.99
0.84
0.71
0.59
0.48
0.38
0.29
0.21
8

Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on 80% Mechanical Efficiency.
The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own
evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that
stipulated in National Oilwell Standard Terms and Conditions of Sale.

Authorized Distributor:

www.natoil.com / customer.service@natoil.com
10000 Richmond, Houston, Texas 77042
(713)346-7500 (phone) (713)346-7366 (fax)

22T-2 Triplex Plunger Pump


Specifications

.750 TYP

4.00
TYP

5.25

24.13

5.25

12.94

2.000
1.999

.500 X .250 KEYWAY


2.625 LONG

DISCHARGE
CONNECTION

.44
A
14.25
B
7.50

SUCTION CONNECTION

.63
2.50

13.75

5.75

Pump Model
22T-2L
22T-2M
22T-2H

Flange Connections
Discharge Connection Sizes Suction Connection Sizes
1 (25.4)-11 1/2 NPT
2 (50.8)-11 1/2 NPT
1 (25.4)-11 1/2 NPT
2 (50.8)-11 1/2 NPT
3/4 (19.1)-14 NPT
1 1/4 (31.8)-11 1/2 NPT

A
3 1/8
3 1/8
3 3/4

Pump Size:
maximum plunger size x stroke length, in.(mm)
2.000 x 2.250 (50.8 x 57.15)
Rated BHP (kW) at 465 RPM: 22 (17)
Rated plunger load, pounds (kg): 2550 (1157)
Maximum discharge pressure: psi (kPa)
L model: 1443 (9949)
M model: 2565 (17688)
H model: 4600 (39797)
Crankshaft extension:
Diameter, in.(mm): 2.000 (50.8)
Length, in.(mm) : 3.875 (98.43)
Keyway width x depth, in.(mm):
1/2 x 1/4 (12.7 x 6.35)
Maximum recommended sheave diameter,
in.(mm): 33.5 (850.9)
For larger sizes: Contact Customer Service
Pinion shaft extension,
if gear reducer is supplied in.(mm)
For belt or chain drive: N/A
For direct drive:
Diameter: N/A
Length: N/A
Keyway (width x length): N/A
Accessory gear reduction unit ratio: N/A
Oil Capacity, gallons (L)
Crankcase: 1-1/4 (4.73)
Gear Reducer - varies with ratio: N/A
Weight, pump only on
wood shipping skids, pounds (kg)
L model: 395 (179)
M model: 395 (179)
H model: 395 (179)
Standard Materials for Fluid Ends:
L model
Cast Ductile Iron
Cast Nickel-Aluminum-Bronze
Cast 316 Stainless Steel
Forged/Plate Carbon Steel
M model
Cast Ductile Iron
Cast Nickel-Aluminum-Bronze
Cast 316 Stainless Steel
Forged/Plate Carbon Steel
H model
Forged 15-5 Stainless Steel

Dimensions (Inches)
B
C
D
E
4 7/8 5 15/16 22 5/8
29 1/2
4 7/8 5 15/16 22 5/8
29 1/2
4 1/4
7 7/8
20
32 1/8

F
11 1/2
11 1/2
13 1/2

22T-2 Triplex Plunger Pump


Performance Data
PUMP

22T-2L
(T225LS)

22T-2M
(T225M)

22T-2H
(T225H)

PUMP

22T-2L
(T225LS)

22T-2M
(T225M)

22T-2H
(T225H)

English Units
Plunger
Plunger
BPD
Dia.
Area
per
In.
Sq. In.
RPM
2.000
3.1416
3.1474
1.875
2.7612
2.7663
1.750
2.4053
2.4097
1.625
2.0739
2.0778
1.500
1.7671
1.7704
1.750
2.4053
2.4097
1.625
2.0739
2.0778
1.500
1.7671
1.7704
1.375
1.4849
1.4876
1.250
1.2272
1.2295
1.125
0.9940
0.9959
1.000
0.7854
0.7869
0.875
0.6013
0.6024
0.750
0.4418
0.4426
Brake Horsepower Required

Metric Units
Plunger
Plunger
Dia.
Area
cm
cm2
51
20.268
48
17.814
44
15.518
41
13.380
38
11.401
44
15.518
41
13.380
38
11.401
35
9.580
32
7.917
29
6.413
25
5.067
22
3.879
19
2.850
Kilowatts Required

50 RPM
GPM
per
RPM
0.0918
0.0807
0.0703
0.0606
0.0516
0.0703
0.0606
0.0516
0.0434
0.0359
0.0290
0.0229
0.0176
0.0129

Max.
Press.
PSI
812
924
1060
1230
1443
1060
1230
1443
1717
2050
2050
3247
4241
4600

BPD
158
139
121
104
89
121
104
89
75
62
50
40
31
23

GPM
4.6
4.0
3.5
3.0
2.6
3.5
3.0
2.6
2.2
1.8
1.5
1.1
0.9
0.6
2.4

50 RPM
M3/Hr
per
RPM
0.0208
0.0183
0.0160
0.0138
0.0117
0.0160
0.0138
0.0117
0.0099
0.0081
0.0066
0.0052
0.0040
0.0029

L/Sec.
per
RPM
0.0058
0.0051
0.0044
0.0038
0.0033
0.0044
0.0038
0.0033
0.0027
0.0023
0.0018
0.0014
0.0011
0.0008

Max.
Press.
kPa
5596
6368
7310
8477
9949
7310
8477
9949
11840
14134
14134
22386
29239
31716

M3/Hr
1.04
0.92
0.80
0.69
0.59
0.80
0.69
0.59
0.49
0.41
0.33
0.26
0.20
0.15

L/Sec.
0.29
0.25
0.22
0.19
0.16
0.22
0.19
0.16
0.14
0.11
0.09
0.07
0.06
0.04
1.8

150 RPM

BPD
473
415
362
312
266
362
312
266
224
185
150
119
91
67

GPM
13.8
12.1
10.5
9.1
7.7
10.5
9.1
7.7
6.5
5.4
4.4
3.4
2.6
1.9

200 RPM

BPD
630
554
482
416
355
482
416
355
298
246
200
158
121
89

GPM
18.4
16.1
14.1
12.1
10.3
14.1
12.1
10.3
8.7
7.2
5.8
4.6
3.5
2.6

250 RPM

BPD
787
692
603
520
443
603
520
443
372
308
249
197
151
111

GPM
22.9
20.2
17.6
15.2
12.9
17.6
15.2
12.9
10.8
9.0
7.3
5.7
4.4
3.2

350 RPM

BPD
1102
969
844
728
620
844
728
620
521
431
349
276
211
155

GPM
32.1
28.2
24.6
21.2
18.1
24.6
21.2
18.1
15.2
12.6
10.2
8.0
6.1
4.5

465 RPM

BPD
1464
1287
1121
967
824
1121
967
824
692
572
464
366
281
206

GPM
42.7
37.5
32.7
28.2
24.0
32.7
28.2
24.0
20.2
16.7
13.5
10.7
8.2
6.0

7.2

9.7

12

17

22

150 RPM

200 RPM

250 RPM

350 RPM

465 RPM

M3/Hr
3.13
2.75
2.39
2.06
1.76
2.39
2.06
1.76
1.48
1.22
0.99
0.78
0.60
0.44

L/Sec.
0.87
0.76
0.67
0.57
0.49
0.67
0.57
0.49
0.41
0.34
0.27
0.22
0.17
0.12
5.4

M3/Hr
4.17
3.66
3.19
2.75
2.35
3.19
2.75
2.35
1.97
1.63
1.32
1.04
0.80
0.59

L/Sec.
1.16
1.02
0.89
0.76
0.65
0.89
0.76
0.65
0.55
0.45
0.37
0.29
0.22
0.16
7.2

M3/Hr
5.21
4.58
3.99
3.44
2.93
3.99
3.44
2.93
2.46
2.04
1.65
1.30
1.00
0.73

L/Sec.
1.45
1.27
1.11
0.96
0.81
1.11
0.96
0.81
0.68
0.57
0.46
0.36
0.28
0.20
9.0

M3/Hr
7.30
6.41
5.59
4.82
4.10
5.59
4.82
4.10
3.45
2.85
2.31
1.82
1.40
1.03

L/Sec.
2.03
1.78
1.55
1.34
1.14
1.55
1.34
1.14
0.96
0.79
0.64
0.51
0.39
0.29
13

M3/Hr
9.69
8.52
7.42
6.40
5.45
7.42
6.40
5.45
4.58
3.79
3.07
2.42
1.86
1.36

L/Sec.
2.69
2.37
2.06
1.78
1.51
2.06
1.78
1.51
1.27
1.05
0.85
0.67
0.52
0.38
17

Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on 90% Mechanical Efficiency.
The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own
evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that
stipulated in National Oilwell Standard Terms and Conditions of Sale.

Authorized Distributor:

www.natoil.com / customer.service@natoil.com
10000 Richmond, Houston, Texas 77042
(713)346-7500 (phone) (713)346-7366 (fax)

30T-2 Triplex Plunger Pump


Specifications

1/2" x 1/4" KEYWAY

7/1
6

1.750
1.749

13/
16 (USABLE SHAFT EXTENSION)

20

5/1
6

DIA.

CENTERLINE
PLUNGER #1

"C"

9/1
6
6

13

1/
8

CENTERLINE
PLUNGER #2

CENTERLINE
PLUNGER #3

1/
14
8

"C"\2

DIA.

9/1
6

4-7/8" HOLES
2.500
2.499

SHAFT EXTENSION
FOR DIRECT DRIVE
5/8" x 5/16" KEYWAY

1" NPT (TYP. BOTH SIDES)

Pump Size
(maximum plunger size x stroke length in.(mm)
2 1/4 x 2 (57.2 x 50.8)
Rated bhp at 500 rpm (kw): 30 (22.4)
Rated plunger load pounds(Kg): 3565 (1617)
Maximum discharge pressure: psi(kPa)
L model: 2000 (13,788)
H model: 5000 (34,470)
Crankshaft extension: in.(mm)
Diameter: 2.5/2.499 (63.5/63.4746)
Length: 4 15/16 (125.4)
Keyway (width x depth):
5/8 x 5/16 (15.88 x 7.94)
Maximum recommended sheave
in.(mm): 37.5 (952.5)
Minimum recommeded sheave
in.(mm): 20 (508)
For larger sizes: Contact Customer Service
Pinion shaft extension,
if gear reducer is supplied in.(mm)
For belt or chain drive:
Contact Customer Service
For direct drive:
Diameter: 1.75/1.749 (44.5/44.425)
Length: 3 13/16 (96.8)
Keyway (width x depth):
1/2 x 1/4 (12.7 x 6.4)
Accessory gear reduction unit ratio:
3.50:1, 3.83:1, 4.2:1
Oil Capacity gallons (L)
Crankcase: 1.2 (4.5)
Gear Reducer: 2/3 (2.5)
Weight, pump only on
wood shipping skids pounds (Kg): 640 (290)
Gear reducer, approximate pounds (Kg):
300 (136.08)

CENTERLINE
DISCHARGE

11

"A"

3/
4

"B"
CENTERLINE
SUCTION

3/
4

1 1/2" STD. PIPE TAP


(CRADLE DRAIN)
7/
21
8
3/
4

21
6

"D"
"E"

Pump Model
30T-2L Threaded
30T-2L Flanged
30T-2H

Flange Connections
Discharge Connection Sizes Suction Connection Sizes
1 1/2 (38.10) Int. Pipe Thds.
2 1/2 (63.5) Int. Pipe Thds.
1 1/2 (38.10) API-2000 RJ
2 1/2 (63.5) ANSI-150 FF
1 (25.4) ANSI-2500 RJ
2 (50.8) ANSI-300 FF

A
3 3/4
3 3/4
3 5/8

Dimensions in inches (mm)


B
C
D
E
4 1/4
15 3/4
24 9/16
32 7/8
4 1/4
18 1/4
24 9/16
34 1/16
4
17 1/2
24 5/16
33 9/16

30T-2 Triplex Plunger Pump


Performance Data
PUMP

30T-2L

30T-2H

PUMP

30T-2L

30T-2H

English Units
Plunger
Plunger
BPD
Dia.
Area
per
In.
Sq. In.
RPM
2.250
3.9761
3.5410
2.000
3.1416
2.7980
1.750
2.4053
2.1430
1.500
1.7671
1.5737
1.500
1.7671
1.5737
1.375
1.4849
1.3234
1.250
1.2272
1.0937
1.125
0.9940
0.8846
1.000
0.7854
0.6994
0.938
0.6910
0.6137
Brake Horsepower Required

GPM
per
RPM
0.1033
0.0816
0.0625
0.0459
0.0459
0.0386
0.0319
0.0258
0.0204
0.0179

Metric Units
Plunger
Plunger
Dia.
Area
mm
cm2
57
25.652
51
20.268
44
15.518
38
11.401
38
11.401
35
9.580
32
7.917
29
6.413
25
5.067
24
4.458
Kilowatts Required

L/Sec.
per
RPM
0.0065
0.0051
0.0039
0.0029
0.0029
0.0024
0.0020
0.0016
0.0013
0.0011

M3/Hr
per
RPM
0.0235
0.0185
0.0142
0.0104
0.0104
0.0088
0.0072
0.0059
0.0046
0.0041

200 * RPM
Max.
Press.
PSI
897
1135
1482
2000
2000
2401
2905
3586
4539
5000

BPD GPM
709
20.66
560
16.32
429
12.50
315
9.18
315
9.18
265
7.72
219
6.38
177
5.16
140
4.08
123
3.58
12.0

300 RPM

BPD
1063
840
643
473
473
398
329
266
210
185

350 RPM

GPM
30.99
24.48
18.75
13.77
13.77
11.58
9.57
7.74
6.12
5.37
18.0

BPD
1240
980
751
551
551
464
383
310
245
215

200 * RPM
300 RPM
Max.
Press.
kPa M3/Hr L/Sec. M3/Hr L/Sec.
6185
4.69
1.30
7.04
1.96
7826
3.71
1.03
5.56
1.54
10218 2.84
0.79
4.26
1.18
13790 2.08
0.58
3.13
0.87
13790 2.08
0.58
3.13
0.87
16554 1.75
0.49
2.63
0.73
20029 1.45
0.40
2.17
0.60
24725 1.17
0.33
1.76
0.49
31295 0.93
0.26
1.39
0.39
34474 0.81
0.23
1.22
0.34
8.9
13.4

GPM
36.16
28.56
21.88
16.07
16.07
13.51
11.17
9.03
7.14
6.27
21.0

350 RPM

M3/Hr L/Sec.
8.21
2.28
6.49
1.80
4.97
1.38
3.65
1.01
3.65
1.01
3.07
0.85
2.54
0.70
2.05
0.57
1.62
0.45
1.42
0.40
15.7

400 RPM

BPD
1417
1120
858
630
630
530
438
354
280
246

GPM
41.32
32.64
25.00
18.36
18.36
15.44
12.76
10.32
8.16
7.16
24

400 RPM

M3/Hr
9.38
7.41
5.68
4.17
4.17
3.51
2.90
2.34
1.85
1.63

450 RPM

BPD
1594
1260
965
709
709
596
493
399
315
277

GPM
46.49
36.72
28.13
20.66
20.66
17.37
14.36
11.61
9.18
8.06

500 RPM

BPD
1771
1399
1072
787
787
662
547
443
350
307

GPM
51.65
40.80
31.25
22.95
22.95
19.30
15.95
12.90
10.20
8.95

27

30

450 RPM

500 RPM

L/Sec. M3/Hr L/Sec. M3/Hr L/Sec.


2.61
10.56
2.93
11.73
3.26
2.06
8.34
2.32
9.27
2.57
1.58
6.39
1.77
7.10
1.97
1.16
4.69
1.30
5.21
1.45
1.16
4.69
1.30
5.21
1.45
0.97
3.94
1.10
4.38
1.22
0.81
3.26
0.91
3.62
1.01
0.65
2.64
0.73
2.93
0.81
0.51
2.08
0.58
2.32
0.64
0.45
1.83
0.51
2.03
0.56
18
20
22

Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on 90% Mechanical Efficiency. * For operations below 200 RPM, auxiliary lubrication system
required. Not all plunger sizes are shown. Contact National-Oilwell for additional information.
The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own
evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that
stipulated in National Oilwell Standard Terms and Conditions of Sale.

Authorized Distributor:

www.natoil.com / customer.service@natoil.com
10000 Richmond, Houston, Texas 77042
(713)346-7500 (phone) (713)346-7366 (fax)

31Q-2 Quintuplex Plunger Pump


Specifications

15.12
C/2

C
18.50

9.25
12.69

4.31

.75
TYP
4 PLACES

.500 x .250 x 3.75 LONG


KEYWAY
2.1252
.124

Pump Size:
maximum plunger size x stroke length, in.(mm):
1.750 x 2.250 (44.5 x 57.15)
Rated BHP (kW) at 490 RPM: 31 (23)
Rated plunger load, pounds (kg): 2030 (921)
Maximum discharge pressure: psi (kPa)
L model: 2042 (14081)
Crankshaft extension:
Diameter, in.(mm): 2.125 (53.98)
Length, in.(mm): 4.31 (109.5)
Keyway width x depth, in.(mm):
1/2 x 1/4 (12.7 x 6.35)
Maximum recommended sheave diameter,
in.(mm): 33.5 (850.9)
For larger sizes: Contact Customer Service
Oil Capacity, gallons (L)
Crankcase: 2 (7.57)
Gear Reducer-varies with ratio: N/A
Weight, pump only on
wood shipping skids, pounds (kg)
L model: 658 (298)
Standard Materials for Fluid Ends:
L model
Cast Ductile Iron
Cast Nickel-Aluminum-Bronze
Cast Duplex Stainless Steel
Forged/Plate Carbon Steel

DISCHARGE
CONNECTION

F
A

4.81
13.38
.44

6.56

.63
2.50

SUCTION
CONNECTION

13.75

6.70

Pump Model
Cast L.E.
Forged L.E.

Flange Connections
Discharge Connection Sizes Suction Connection Sizes
1 NPT (25.4)-11 1/2 THDS
2 NPT (50.8)-11 1/2 THDS
1 NPT (25.4)-11 1/2 THDS
2 NPT (50.8)-11 1/2 THDS

A
3 3/8
3 1/2

Dimensions (Inches)
B
C
D
E
4 7/8
19 1/2
22 5/8
30 3/8
4 7/8
20
20 3/8
30 3/8

F
5 15/16
6 3/16

31Q-2 Quintuplex Plunger Pump


Performance Data
PUMP

31Q-2L
(5P200A)

PUMP

31Q-2L
(5P200A)

English Units
Plunger
Plunger
BPD
Dia.
Area
per
In.
Sq. In.
RPM
1.750
2.4053
4.0162
1.625
2.0739
3.4630
1.500
1.7671
2.9507
1.375
1.4849
2.4794
1.250
1.2272
2.0491
1.125
0.9940
1.6598
Brake Horsepower Required

GPM
per
RPM
0.1171
0.1010
0.0861
0.0723
0.0598
0.0484

Metric Units
Plunger
Plunger
Dia.
Area
cm
cm2
44
15.518
41
13.380
38
11.401
35
9.580
32
7.917
29
6.413
Kilowatts Required

L/Sec.
per
RPM
0.0074
0.0064
0.0054
0.0046
0.0038
0.0031

M3/Hr
per
RPM
0.0266
0.0229
0.0195
0.0164
0.0136
0.0110

50 RPM
Max.
Press.
PSI
844
979
1149
1367
1654
2042

BPD
201
174
148
124
103
83

GPM
5.86
5.05
4.30
3.62
2.99
2.42
4

150 RPM

BPD
603
520
443
372
308
249

250 RPM

GPM
17.6
15.2
12.9
10.8
8.96
7.26

BPD
1005
866
738
620
513
415

10

50 RPM
150 RPM
Max.
Press.
kPa M3/Hr L/Sec. M3/Hr L/Sec.
5819
1.33
0.37
3.99
1.11
6749
1.15
0.32
3.44
0.96
7920
0.98
0.27
2.93
0.81
9426
0.82
0.23
2.46
0.68
11405 0.68
0.19
2.04
0.57
14081 0.55
0.15
1.65
0.46
3.0
7.5

350 RPM

GPM
29.3
25.3
21.5
18.1
14.9
12.1

BPD
1406
1213
1033
868
718
581

GPM
41.0
35.4
30.1
25.3
20.9
16.9

400 RPM

BPD
1607
1386
1181
992
820
664

GPM
46.9
40.4
34.4
28.9
23.9
19.4

490 RPM

BPD
1968
1697
1446
1215
1005
814

GPM
57.4
49.5
42.2
35.4
29.3
23.7

17

22

26

31

250 RPM

350 RPM

400 RPM

490 RPM

M3/Hr
6.65
5.73
4.89
4.11
3.39
2.75

L/Sec.
1.85
1.59
1.36
1.14
0.94
0.76
13

M3/Hr
9.31
8.03
6.84
5.75
4.75
3.85

L/Sec. M3/Hr L/Sec. M3/Hr L/Sec.


2.59
10.64
2.96
13.04
3.62
2.23
9.18
2.55
11.24
3.12
1.90
7.82
2.17
9.58
2.66
1.60
6.57
1.82
8.05
2.24
1.32
5.43
1.51
6.65
1.85
1.07
4.40
1.22
5.39
1.50
17
19
23

Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on 90% Mechanical Efficiency.
The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own
evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that
stipulated in National Oilwell Standard Terms and Conditions of Sale.

Authorized Distributor:

www.natoil.com / customer.service@natoil.com
10000 Richmond, Houston, Texas 77042
(713)346-7500 (phone) (713)346-7366 (fax)

32T-2 Triplex Plunger Pump


Specifications

.75
TYP
4 PLACES

4.00
TYP

5.25

24.13

5.25

12.94

2.000
1.999

.500 X .250 KEYWAY


2.625 LONG

DISCHARGE
CONNECTION

.44
A
14.25
B
7.50

SUCTION CONNECTION

.63
2.50

13.75

5.75

Pump Size:
maximum plunger size x stroke length, in.(mm):
2.000 x 2.250 (50.8 x 57.15)
Rated BHP (kW) at 465 RPM: 32 (24)
Rated plunger load, pounds (kg): Spec
Maximum discharge pressure: psi (kPa)
L model: 2037 (14046)
M model: 2050 (14134)
H model: 4600 (31716)
Crankshaft extension:
Diameter, in.(mm): 2.000 (50.8)
Length, in.(mm): 3.875 (98.4)
Keyway width x depth, in.(mm):
1/2 x 1/4 (12.7 x 6.35)
Maximum recommended sheave diameter,
in.(mm): 33.5 (850.9)
For larger sizes: Contact Customer Service
Pinion shaft extension,
if gear reducer is supplied in.(mm)
For belt or chain drive: N/A
For direct drive:
Diameter: N/A
Length: N/A
Keyway (width x length): N/A
Accessory gear reduction unit ratio: N/A
Oil Capacity, gallons (L)
Crankcase: 1-1/4 (4.73)
Gear Reducer-varies with ratio: N/A
Weight, pump only on
wood shipping skids, pounds (kg): 395 (179)
Standard Materials for Fluid Ends:
L & M models
Cast Ductile Iron
Cast Nickel-Aluminum-Bronze
Cast 316 Stainless Steel
Forged/Plate Carbon Steel
H model
Forged 15-5 Stainless Steel

Pump Model
32T-2L
32T-2M
32T-2H

Flange Connections
Discharge Connection Sizes Suction Connection Sizes
1 (25.4)-11 1/2 NPT
2 (50.8)-11 1/2 NPT
1 (25.4)-11 1/2 NPT
2 (50.8)-11 1/2 NPT
3/4 (19.1)-14 NPT
1 1/4 (31.8)-11 1/2 NPT

A
3 3/8
3 1/8
3 3/4

Dimensions (Inches)
B
C
D
E
4 7/8 5 15/16 22 5/8
29 1/2
4 7/8 5 15/16 22 5/8
29 1/2
4 1/4
7 7/8
20
32 1/8

F
11 1/2
11 1/2
13 1/2

32T-2 Triplex Plunger Pump


Performance Data
PUMP

32T-2L
(T225LS)

32T-2M
(T225M)

32T-2H
(T225H)

PUMP

32T-2L
(T225LS)

32T-2M
(T225M)

32T-2H
(T225H)

English Units
Plunger
Plunger
BPD
Dia.
Area
per
In.
Sq. In.
RPM
2.000
3.1416
3.1474
1.875
2.7612
2.7663
1.750
2.4053
2.4097
1.625
2.0739
2.0778
1.500
1.7671
1.7704
1.750
2.4053
2.4097
1.625
2.0739
2.0778
1.500
1.7671
1.7704
1.375
1.4849
1.4876
1.250
1.2272
1.2295
1.125
0.9940
0.9959
1.000
0.7854
0.7869
0.875
0.6013
0.6024
0.750
0.4418
0.4426
Brake Horsepower Required

GPM
per
RPM
0.0918
0.0807
0.0703
0.0606
0.0516
0.0703
0.0606
0.0516
0.0434
0.0359
0.0290
0.0229
0.0176
0.0129

Metric Units
Plunger
Plunger
Dia.
Area
cm
cm2
51
20.268
48
17.814
44
15.518
41
13.380
38
11.401
44
15.518
41
13.380
38
11.401
35
9.580
32
7.917
29
6.413
25
5.067
22
3.879
19
2.850
Kilowatts Required

L/Sec.
per
RPM
0.0058
0.0051
0.0044
0.0038
0.0033
0.0044
0.0038
0.0033
0.0027
0.0023
0.0018
0.0014
0.0011
0.0008

M3/Hr
per
RPM
0.0208
0.0183
0.0160
0.0138
0.0117
0.0160
0.0138
0.0117
0.0099
0.0081
0.0066
0.0052
0.0040
0.0029

50 RPM
Max.
Press.
PSI
1146
1304
1497
1736
2037
1497
1736
2037
2050
2050
2050
4584
4600
4600

BPD
158
139
121
104
89
121
104
89
75
62
50
40
31
23

GPM
4.59
4.03
3.51
3.03
2.58
3.51
3.03
2.58
2.17
1.79
1.45
1.15
0.88
0.65
3.4

150 RPM

200 RPM

BPD GPM
473
13.8
415
12.1
362
10.5
312
9.1
266
7.7
362
10.5
312
9.09
266
7.75
224
6.51
185
5.38
150
4.36
119
3.44
91
2.64
67
1.94
10.2

BPD
630
554
482
416
355
482
416
355
298
246
200
158
121
89

50 RPM
150 RPM
Max.
Press.
kPa M3/Hr L/Sec. M3/Hr L/Sec.
7901
1.04
0.29
3.13
0.87
8989
0.92
0.25
2.75
0.76
10319 0.80
0.22
2.39
0.67
11968 0.69
0.19
2.06
0.57
14046 0.59
0.16
1.76
0.49
10319 0.80
0.22
2.39
0.67
11968 0.69
0.19
2.06
0.57
14046 0.59
0.16
1.76
0.49
14134 0.49
0.14
1.48
0.41
14134 0.41
0.11
1.22
0.34
14134 0.33
0.09
0.99
0.27
31603 0.26
0.07
0.78
0.22
31716 0.20
0.06
0.60
0.17
31716 0.15
0.04
0.44
0.12
2.5
7.6

250 RPM

GPM
18.4
16.1
14.1
12.1
10.3
14.1
12.1
10.3
8.68
7.17
5.81
4.59
3.51
2.58
13.6

BPD
787
692
603
520
443
603
520
443
372
308
249
197
151
111

200 RPM

M3/Hr L/Sec.
4.17
1.16
3.66
1.02
3.19
0.89
2.75
0.76
2.35
0.65
3.19
0.89
2.75
0.76
2.35
0.65
1.97
0.55
1.63
0.45
1.32
0.37
1.04
0.29
0.80
0.22
0.59
0.16
10.2

GPM
22.9
20.2
17.6
15.2
12.9
17.6
15.2
12.9
10.8
8.96
7.26
5.74
4.39
3.23
17

250 RPM

M3/Hr
5.21
4.58
3.99
3.44
2.93
3.99
3.44
2.93
2.46
2.04
1.65
1.30
1.00
0.73

350 RPM

BPD
1102
969
844
728
620
844
728
620
521
431
349
276
211
155

GPM
32.1
28.2
24.6
21.2
18.1
24.6
21.2
18.1
15.2
12.6
10.2
8.03
6.15
4.52

465 RPM

BPD
1464
1287
1121
967
824
1121
967
824
692
572
464
366
281
206

GPM
42.7
37.5
32.7
28.2
24.0
32.7
28.2
24.0
20.2
16.7
13.5
10.7
8.17
6.00

24

32

350 RPM

465 RPM

L/Sec. M3/Hr L/Sec. M3/Hr L/Sec.


1.45
7.30
2.03
9.69
2.69
1.27
6.41
1.78
8.52
2.37
1.11
5.59
1.55
7.42
2.06
0.96
4.82
1.34
6.40
1.78
0.81
4.10
1.14
5.45
1.51
1.11
5.59
1.55
7.42
2.06
0.96
4.82
1.34
6.40
1.78
0.81
4.10
1.14
5.45
1.51
0.68
3.45
0.96
4.58
1.27
0.57
2.85
0.79
3.79
1.05
0.46
2.31
0.64
3.07
0.85
0.36
1.82
0.51
2.42
0.67
0.28
1.40
0.39
1.86
0.52
0.20
1.03
0.29
1.36
0.38
12.7
18
24

Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on 90% Mechanical Efficiency.
The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own
evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that
stipulated in National Oilwell Standard Terms and Conditions of Sale.

Authorized Distributor:

www.natoil.com / customer.service@natoil.com
10000 Richmond, Houston, Texas 77042
(713)346-7500 (phone) (713)346-7366 (fax)

55T-3 Triplex Plunger Pump


Specifications
.75
TYP
2 PLACES
17.44

E/2

8.50

8.50
12.19
16.63

2.500
2.499

.625 x .313 KEYWAY


3.875 LONG

D
DISCHARGE
CONNECTION

7.50

6.00
A
14.16
B

1.00
TYP

Pump Size:
maximum plunger size x stroke length, in.(mm)
2.500 x 3.000 (63.5 x 76.2)
Rated BHP (kW) at 500 RPM: 55 (41)
Rated plunger load, pounds (kg): 4370 (1982)
Maximum discharge pressure: psi (kPa)
L model: 1391 (9591)
SC model: 1817 (12527)
LS model: 1480 (10204)
M model: 3561 (24552)
MS model: 2473 (17050)
H model: 5564 (38363)
Crankshaft extension:
Diameter, in.(mm): 3.500 (88.9)
Length, in.(mm): 3.875 (98.43)
Keyway width x depth, in.(mm):
5/8 x 5/16 (15.88 x 7.94)
Maximum recommended sheave
in.(mm): 38 (965.2)
For larger sizes: Contact Customer Service
Oil Capacity, gallons (L)
Crankcase: 2.50 (9.46)
Weight, pump only on
wood shipping skids, pounds (kg): 895 (406)
Weight varies with pump model
Standard Materials for Fluid Ends:
L & M models
Cast Nickel-Aluminum-Bronze
SC model
Cast Ductile Iron
LS, MS, & H models
Carbon Steel Plate

SUCTION
CONNECTION
5/8-11UNC-3B
3/4 FULL THREAD
1 PLACE
C

5.25

Pump Model
55T-3L
55T-3LS
55T-3M
55T-3MS
55T-3H

30.75

Flange Connections
Discharge Connection Sizes Suction Connection Sizes
2 (50.8)-NPT
2 1/2 (63.5)-NPT
1 1/2 (38.1)-NPT
2 (50.8)-NPT
2 (50.8)-NPT
2 1/2 (63.5)-NPT
1 1/2 (38.1)-NPT
2 (50.8)-NPT
1 1/2 (38.1)-NPT
2 (50.8)-NPT

A
3 3/16
3 3/8
3 3/16
3 3/8
3 3/8

Dimensions (Inches)
B
C
D
E
3 3/4
28 3/4 39 3/16
18
4
28 3/4
41
18 1/2
3 3/4
28 3/4 39 3/16
18
4
28 3/4
41
18 1/2
4
28 3/4
41
18 1/2

F
5 11/32
6 15/32
5 11/32
6 15/32
6 15/32

55T-3 Triplex Plunger Pump


Performance Data
PUMP

55T-3L
(3364-7)
55T-3SC
(3364-5SC)
55T-3LS
(3364-6)

55T-3M
(3364-3)
55T-3MS
(3364-2)
55T-3H
(3364-1)

PUMP

55T-3L
(3364-7)
55T-3SC
(3364-5SC)
55T-3LS
(3364-6)

55T-3M
(3364-3)
55T-3MS
(3364-2)
55T-3H
(3364-1)

English Units
Plunger
Plunger
BPD
Dia.
Area
per
In.
Sq. In.
RPM
2.500
4.9087
6.5571
2.250
3.9761
5.3113
2.000
3.1416
4.1966
2.250
3.9761
5.3113
2.000
3.1416
4.1966
1.750
2.4053
3.2130
2.500
4.9087
6.5571
2.250
3.9761
5.3113
2.000
3.1416
4.1966
1.750
2.4053
3.2130
1.750
2.4053
3.2130
1.500
1.7671
2.3606
1.250
1.2272
1.6393
1.750
2.4053
3.2130
1.500
1.7671
2.3606
1.250
1.2272
1.6393
1.000
0.7854
1.0491
Brake Horsepower Required

GPM
per
RPM
0.1912
0.1549
0.1224
0.1549
0.1224
0.0937
0.1912
0.1549
0.1224
0.0937
0.0937
0.0688
0.0478
0.0937
0.0688
0.0478
0.0306

Metric Units
Plunger
Plunger
Dia.
Area
mm
cm2
64
31.669
57
25.652
51
20.268
57
25.652
51
20.268
44
15.518
64
31.669
57
25.652
51
20.268
44
15.518
44
15.518
38
11.401
32
7.917
44
15.518
38
11.401
32
7.917
25
5.067
Kilowatts Required

L/Sec.
per
RPM
0.0121
0.0098
0.0077
0.0098
0.0077
0.0059
0.0121
0.0098
0.0077
0.0059
0.0059
0.0043
0.0030
0.0059
0.0043
0.0030
0.0019

M3/Hr
per
RPM
0.0434
0.0352
0.0278
0.0352
0.0278
0.0213
0.0434
0.0352
0.0278
0.0213
0.0213
0.0156
0.0109
0.0213
0.0156
0.0109
0.0069

100 RPM
Max.
Press.
PSI
890
1099
1391
1099
1391
1817
890
1099
1391
1480
1817
2473
3561
1817
2473
3300
3300

BPD
656
532
420
532
420
322
656
532
420
322
322
237
164
322
237
164
105

GPM
19.12
15.49
12.24
15.49
12.24
9.37
19.12
15.49
12.24
9.37
9.37
6.88
4.78
9.37
6.88
4.78
3.06
11

200 RPM

BPD
1312
1063
840
1063
840
643
1312
1063
840
643
643
473
328
643
473
328
210

250 RPM

GPM
38.25
30.98
24.48
30.98
24.48
18.74
38.25
30.98
24.48
18.74
18.74
13.77
9.56
18.74
13.77
9.56
6.12

BPD
1640
1328
1050
1328
1050
804
1640
1328
1050
804
804
591
410
804
591
410
263

22

100 RPM
200 RPM
Max.
Press.
kPa M3/Hr L/Sec. M3/Hr L/Sec.
6138
4.34
1.21
8.69
2.41
7578
3.52
0.98
7.04
1.95
9591
2.78
0.77
5.56
1.54
7578
3.52
0.98
7.04
1.95
9591
2.78
0.77
5.56
1.54
12527 2.13
0.59
4.26
1.18
6138
4.34
1.21
8.69
2.41
7578
3.52
0.98
7.04
1.95
9591
2.78
0.77
5.56
1.54
10204 2.13
0.59
4.26
1.18
12527 2.13
0.59
4.26
1.18
17050 1.56
0.43
3.13
0.87
24552 1.09
0.30
2.17
0.60
12527 2.13
0.59
4.26
1.18
17050 1.56
0.43
3.13
0.87
24552 1.09
0.30
2.17
0.60
38363 0.69
0.19
1.39
0.39
8
16

GPM
47.81
38.73
30.60
38.73
30.60
23.43
47.81
38.73
30.60
23.43
23.43
17.21
11.95
23.43
17.21
11.95
7.65

350 RPM

BPD
2295
1859
1469
1859
1469
1125
2295
1859
1469
1125
1125
827
574
1125
827
574
368

GPM
66.94
54.22
42.84
54.22
42.84
32.80
66.94
54.22
42.84
32.80
32.80
24.10
16.73
32.80
24.10
16.73
10.71

420 RPM

BPD
2754
2231
1763
2231
1763
1350
2754
2231
1763
1350
1350
992
689
1350
992
689
441

GPM
80.32
65.06
51.41
65.06
51.41
39.36
80.32
65.06
51.41
39.36
39.36
28.92
20.08
39.36
28.92
20.08
12.85

500 * RPM

BPD
3279
2656
2099
2656
2099
1607
3279
2656
2099
1607
1607
1181
820
1607
1181
820
525

GPM
95.62
77.46
61.20
77.46
61.20
46.86
95.62
77.46
61.20
46.86
46.86
34.42
23.91
46.86
34.42
23.91
15.30

28

39

46

55

250 RPM

350 RPM

420 RPM

500 * RPM

M3/Hr
10.86
8.80
6.95
8.80
6.95
5.32
10.86
8.80
6.95
5.32
5.32
3.91
2.71
5.32
3.91
2.71
1.74

L/Sec.
3.02
2.44
1.93
2.44
1.93
1.48
3.02
2.44
1.93
1.48
1.48
1.09
0.75
1.48
1.09
0.75
0.48
21

M3/Hr
15.20
12.31
9.73
12.31
9.73
7.45
15.20
12.31
9.73
7.45
7.45
5.47
3.80
7.45
5.47
3.80
2.43

L/Sec. M3/Hr L/Sec. M3/Hr L/Sec.


4.22
18.24
5.07
21.72
6.03
3.42
14.78
4.10
17.59
4.89
2.70
11.67
3.24
13.90
3.86
3.42
14.78
4.10
17.59
4.89
2.70
11.67
3.24
13.90
3.86
2.07
8.94
2.48
10.64
2.96
4.22
18.24
5.07
21.72
6.03
3.42
14.78
4.10
17.59
4.89
2.70
11.67
3.24
13.90
3.86
2.07
8.94
2.48
10.64
2.96
2.07
8.94
2.48
10.64
2.96
1.52
6.57
1.82
7.82
2.17
1.06
4.56
1.27
5.43
1.51
2.07
8.94
2.48
10.64
2.96
1.52
6.57
1.82
7.82
2.17
1.06
4.56
1.27
5.43
1.51
0.68
2.92
0.81
3.47
0.97
29
35
41

Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on 90% Mechanical Efficiency.*For Speeds above 420 RPM - consult the Factory.
The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own
evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that
stipulated in National Oilwell Standard Terms and Conditions of Sale.

Authorized Distributor:

www.natoil.com / customer.service@natoil.com
10000 Richmond, Houston, Texas 77042
(713)346-7500 (phone) (713)346-7366 (fax)

59T-3 Triplex Plunger Pump


Specifications
14.31

C
13.00

6.50
C/2
11.56

.75
TYP
4 PLACES

4.13

2.500
2.499

ROTATION
DIRECTION
DISCHARGE
CONNECTION

F
A
17.89

.75

7.37

.63

4.00

G
7.43

SUCTION
CONNECTION

19.38

Pump Model
59T-3L
59T-3M
59T-3MS
59T-3H

Flange Connections
Discharge Connection Sizes Suction Connection Sizes
2 1/2 (63.5)-8 NPT
4 (101.6)-8 NPT
2 (50.8)-11 1/2 NPT
2 1/2 (63.5)-8 NPT
2 (50.8)-11 1/2 NPT
2 (63.5)-8 NPT
1 (25.4)-11 1/2 NPT
1 1/2 (38.1)-11 1/2 NPT

A
5 1/8
3 7/16
4 9/16
3 7/8

Pump Size:
maximum plunger size x stroke length, in.(mm):
3.00 x 3.500 (76.2 x 88.9)
Rated BHP (kW) at 420 RPM: 59 (44)
Rated plunger load, pounds (kg): 4760 (2159)
Maximum discharge pressure: psi (kPa)
L model: 970 (6686)
M model: 2295 (15825)
MS model: 4789 (33017)
H model: 10000 (68948)
Crankshaft extension:
Diameter, in.(mm): 2.500 (63.5)
Length, in (mm): 4.13 (104.9)
Keyway width x depth, in.(mm):
5/8 x 5/16 (15.88 x 7.94)
Maximum recommended sheave diameter,
in.(mm): 38 (965.2)
For larger sizes: Contact Factory
Pinion shaft extension,
if gear reducer is supplied, in.(mm)
For belt or chain drive: N/A
For direct drive: Diameter: 2.000 (50.8)
Length: 4.250 (108.0)
Keyway width x depth:
1/2 x 1/4 (12.70 x 6.35)
Accessory gear reduction unit:
3.00:1, 3.12:1, 3.23:1, 3.36:1, 3.49:1,
3.62:1, 3.78:1, 3.94:1, 4.11:1, 4.29:1,
4.48:1, 4.69:1, 4.93:1, 5.17:1
Oil Capacity, gallons (L)
Crankcase: 2.50 (9.46)
Gear Reducer - varies with ratio:
1.25 to 1.50 (4.73 to 5.68)
Weight, pump only on
wood shipping skids, pounds (kg)
L model: 1100 (499)
M model: 980 (445)
MS model: 1080 (490)
H model: 1035 (469)
Standard Materials For Fluid End Bodies
L model
Cast Ductile Iron
Forged/Plate Carbon Steel
Cast Nickel-Aluminum-Bronze
Cast Duplex Stainless Steel
M model
Cast Ductile Iron
Cast/Forged/Plate Carbon Steel
Cast Nickel-Aluminum-Bronze
Cast Duplex Stainless Steel
MS model
Forged Nickel-Aluminum-Bronze
Forged 316 Stainless Steel
Forged/Plate Carbon Steel
H model
Forged 15-5 Stainless Steel

Dimensions (Inches)
B
C
D
E
7
17 1/8
28
41 1/16
5 3/8
16 5/8 27 3/16 40 5/16
5 3/8
16 1/2
26 7/8
40 1/16
4 3/8
28
24 3/4
39 5/8

F
9 7/8
8 1/8
9 5/16
8 3/16

G
1 7/8
-3/4
-7/8
-7/8

59T-3 Triplex Plunger Pump


Performance Data
PUMP

59T-3L
(T365AL)

59T-3M
(T365AM)

59T-3MS
(T365MS)

59T-3H
(T365H)

PUMP

59T-3L
(T365AL)

59T-3M
(T365AM)

59T-3MS
(T365MS)

59T-3H
(T365H)

English Units
Plunger
Plunger
BPD
Dia.
Area
per
In.
Sq. In.
RPM
3.000
7.0686
11.0160
2.875
6.4918
10.1171
2.750
5.9396
9.2565
2.625
5.4119
8.4341
2.500
4.9087
7.6500
2.500
4.9087
7.6500
2.375
4.4301
6.9041
2.250
3.9761
6.1965
2.125
3.5466
5.5271
2.000
3.1416
4.8960
1.875
2.7612
4.3031
1.750
2.4053
3.7485
1.625
2.0739
3.2321
1.500
1.7671
2.7540
1.375
1.4849
2.3141
1.250
1.2272
1.9125
1.125
0.9940
1.5491
1.000
0.7854
1.2240
0.875
0.6013
0.9371
0.750
0.4418
0.6885
Brake Horsepower Required

GPM
per
RPM
0.3213
0.2951
0.2700
0.2460
0.2231
0.2231
0.2014
0.1807
0.1612
0.1428
0.1255
0.1093
0.0943
0.0803
0.0675
0.0558
0.0452
0.0357
0.0273
0.0201

Metric Units
Plunger
Plunger
Dia.
Area
mm
cm2
76
45.604
73
41.883
70
38.320
67
34.915
64
31.669
64
31.669
60
28.581
57
25.652
54
22.881
51
20.268
48
17.814
44
15.518
41
13.380
38
11.401
35
9.580
32
7.917
29
6.413
25
5.067
22
3.879
19
2.850
Kilowatts Required

L/Sec.
per
RPM
0.0203
0.0186
0.0170
0.0155
0.0141
0.0141
0.0127
0.0114
0.0102
0.0090
0.0079
0.0069
0.0059
0.0051
0.0043
0.0035
0.0029
0.0023
0.0017
0.0013

M3/Hr
per
RPM
0.0730
0.0670
0.0613
0.0559
0.0507
0.0507
0.0457
0.0410
0.0366
0.0324
0.0285
0.0248
0.0214
0.0182
0.0153
0.0127
0.0103
0.0081
0.0062
0.0046

50 RPM
Max.
Press.
PSI
673
733
801
880
970
970
1074
1197
1342
1515
1724
1979
2295
2694
3206
3879
4789
6061
7916
10000

BPD
551
506
463
422
383
383
346
310
277
245
216
188
162
138
116
96
78
62
47
35

GPM
16.1
14.8
13.50
12.30
11.16
11.16
10.07
9.04
8.06
7.14
6.28
5.47
4.71
4.02
3.37
2.79
2.26
1.78
1.37
1.00
7

150 RPM

BPD
1653
1518
1389
1266
1148
1148
1036
930
830
735
646
563
485
414
348
287
233
184
141
104

250 RPM

GPM
48.19
44.26
40.50
36.90
33.47
33.47
30.21
27.11
24.18
21.42
18.83
16.40
14.14
12.05
10.12
8.37
6.78
5.35
4.10
3.01

BPD
2754
2530
2315
2109
1913
1913
1727
1550
1382
1224
1076
938
809
689
579
479
388
306
235
173

21

50 RPM
150 RPM
Max.
Press.
kPa M3/Hr L/Sec. M3/Hr L/Sec.
4643
3.65
1.01 10.95
3.04
5055
3.35
0.93 10.05
2.79
5526
3.07
0.85
9.20
2.55
6064
2.79
0.78
8.38
2.33
6686
2.53
0.70
7.60
2.11
6686
2.53
0.70
7.60
2.11
7408
2.29
0.64
6.86
1.91
8254
2.05
0.57
6.16
1.71
9254
1.83
0.51
5.49
1.53
10447 1.62
0.45
4.86
1.35
11886 1.43
0.40
4.28
1.19
13645 1.24
0.34
3.72
1.03
15825 1.07
0.30
3.21
0.89
18572 0.91
0.25
2.74
0.76
22102 0.77
0.21
2.30
0.64
26744 0.63
0.18
1.90
0.53
33017 0.51
0.14
1.54
0.43
41787 0.41
0.11
1.22
0.34
54579 0.31
0.09
0.93
0.26
68948 0.23
0.06
0.68
0.19
5
16

GPM
80.32
73.77
67.50
61.50
55.78
55.78
50.34
45.18
40.30
35.70
31.38
27.33
23.57
20.08
16.87
13.95
11.30
8.92
6.83
5.02

300 RPM

BPD
3305
3036
2777
2531
2295
2295
2072
1859
1659
1469
1291
1125
970
827
695
574
465
368
282
207

GPM
96.39
88.52
80.99
73.80
66.94
66.94
60.41
54.22
48.36
42.84
37.65
32.80
28.28
24.10
20.25
16.73
13.55
10.71
8.20
6.02

350 RPM

BPD
3856
3541
3240
2952
2678
2678
2417
2169
1935
1714
1507
1312
1132
964
810
670
543
429
328
241

GPM
112.5
103.3
94.49
86.10
78.09
78.09
70.48
63.26
56.42
49.98
43.93
38.27
32.99
28.11
23.62
19.52
15.81
12.49
9.57
7.03

420 RPM

BPD
4627
4250
3888
3543
3213
3213
2900
2603
2322
2057
1808
1575
1358
1157
972
804
651
515
394
290

GPM
134.9
123.9
113.4
103.3
93.71
93.71
84.58
75.91
67.71
59.98
52.71
45.92
39.59
33.74
28.35
23.43
18.98
14.99
11.48
8.43

35

42

49

59

250 RPM

300 RPM

350 RPM

420 RPM

M3/Hr
18.24
16.75
15.33
13.97
12.67
12.67
11.43
10.26
9.15
8.11
7.13
6.21
5.35
4.56
3.83
3.17
2.57
2.03
1.55
1.14

L/Sec.
5.07
4.65
4.26
3.88
3.52
3.52
3.18
2.85
2.54
2.25
1.98
1.72
1.49
1.27
1.06
0.88
0.71
0.56
0.43
0.32
26

M3/Hr
21.89
20.10
18.39
16.76
15.20
15.20
13.72
12.31
10.98
9.73
8.55
7.45
6.42
5.47
4.60
3.80
3.08
2.43
1.86
1.37

L/Sec. M3/Hr L/Sec. M3/Hr L/Sec.


6.08
25.54
7.09
30.65
8.51
5.59
23.45
6.52
28.15
7.82
5.11
21.46
5.96
25.75
7.15
4.66
19.55
5.43
23.46
6.52
4.22
17.74
4.93
21.28
5.91
4.22
17.74
4.93
21.28
5.91
3.81
16.01
4.45
19.21
5.34
3.42
14.37
3.99
17.24
4.79
3.05
12.81
3.56
15.38
4.27
2.70
11.35
3.15
13.62
3.78
2.38
9.98
2.77
11.97
3.33
2.07
8.69
2.41
10.43
2.90
1.78
7.49
2.08
8.99
2.50
1.52
6.38
1.77
7.66
2.13
1.28
5.36
1.49
6.44
1.79
1.06
4.43
1.23
5.32
1.48
0.86
3.59
1.00
4.31
1.20
0.68
2.84
0.79
3.41
0.95
0.52
2.17
0.60
2.61
0.72
0.38
1.60
0.44
1.92
0.53
31
37
44

Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on 90% Mechanical Efficiency.
The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own
evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that
stipulated in National Oilwell Standard Terms and Conditions of Sale.

Authorized Distributor:

www.natoil.com / customer.service@natoil.com
10000 Richmond, Houston, Texas 77042
(713)346-7500 (phone) (713)346-7366 (fax)

60T-3 Triplex Plunger Pump


Specifications

5/8" x 5/16 KEYWAY

2.250

3 7/8" (USEABLE SHAFT EXT.)

DIA.

2.249

SUCTION & DISCHARGE


CONNECTIONS MAY BE

23

9/1
6

MADE AT EITHER END

3/
4

17

11/
16

"C"/2

1/
5
2

"C"

18

1/
5
2

3.000
2.999

DIA.

5 1/8" (USEABLE SHAFT EXT.)

7/8" DIA. HOLE THRU

3/4" x 3/8" KEYWAY

4 PLACES, AS SHOWN

1 1/2" N.P.T.
(TYP. BOTH SIDES)
DISCHARGE

7/
8

1/
4

"B"

7/
8

15

5/
8

"A"

CENTERLINE

SUCTION
1

CENTERLINE

2" STD. PIPE TAP


5/
8

(CRADLE DRAIN)

30
3/4" STD. PIPE TAP

1/
2

7
(POWER END OIL DRAIN)

"D"

Pump Size:
maximum plunger size x stroke length in.(mm):
3 x 3 (76.2 x 76.2)
Rated bhp at 500 rpm (kw): 60 (44.74)
Rated plunger load, pounds(Kg): 4750 (2154.5)
Maximum discharge pressure: psi(kPa)
L model: 1500 (10,341)
M model: 3200 (22,061)
H model: 5000 (34,470)
Crankshaft extension: in.(mm)
Diameter: 3 (76.2)
Length long side: 5 3/4 (146.2)
Length short side: 5 9/16 (141.3)
Keyway (width x depth):
3/4 x 3/8 (19.1 x 9.5)
Maximum recommended sheave
in.(mm): 37.5 (952.5)
Minimum recommended sheave
in. (mm): 20 (508)
For larger sizes: Contact Customer Service
Pinion shaft extension,
if gear reducer is supplied in.(mm)
For belt or chain drive:
Contact Customer Service
For direct drive: Diameter: 2 1/4 (57.2)
Length: 3 7/8 (98.4)
Keyway (width x depth):
5/8 x 5/16 (15.9 x 7.9)
Accessory gear reduction unit ratios:
2.34:1, 2.77:1, 3.03:1, 3.5:1
Oil Capacity, gallons (L)
Crankcase: 2 (7.6)
Gear Reducer: 1 (3/8)
Weight, pump only on
wood shipping skids pounds (Kg):
1145 (519.3)
Gear reducer, approximate pounds (Kg):
315 (142.88)

3/
8

"E"

Pump Model
60T-3L Threaded
60T-3L Flanged
60T-3M
60T-3H

Flange Connection
Discharge Connection Sizes Suction Connection Sizes
2 (50.8) Int. Pipe Thds.
3 (76.2) Int. Pipe Thds.
2 (50.8) API-2000# RJ
3 (76.2) ANSI-150#FF
1 1/2 (38.1) API-5000#RJ
2 1/2 (63.5) ANSI-150 FF
1 1/4 (31.75) ANSI-2500 RJ
2 1/2 (63.5) ANSI-300 FF

A
4 1/8
4 1/8
4
4

Dimensions in inches (mm)


B
C
D
E
4 7/8
20 1/2
33 5/8
43 3/4
4 7/8
20 1/2
33 5/8
44 7/8
4 1/2
22 1/4
33 5/8
43 3/4
4 1/2
22 5/8
33 5/8
44 7/8

60T-3 Triplex Plunger Pump


Performance Data
PUMP

60T-3L

60T-3M

60T-3H

PUMP

60T-3L

60T-3M

60T-3H

English Units
Plunger
Plunger
BPD
Dia.
Area
per
In.
Sq. In.
RPM
3.000
7.0686
9.4423
2.750
5.9396
7.9341
2.500
4.9087
6.5571
2.250
3.9761
5.3113
2.000
3.1416
4.1966
2.000
3.1416
4.1966
1.750
2.4053
3.2130
1.625
2.0739
2.7704
1.500
1.7671
2.3606
1.375
1.4849
1.9835
1.375
1.4849
1.9835
1.250
1.2272
1.6393
1.125
0.9940
1.3278
1.000
0.7854
1.0491
Brake Horsepower Required

GPM
per
RPM
0.2754
0.2314
0.1912
0.1549
0.1224
0.1224
0.0937
0.0808
0.0688
0.0579
0.0579
0.0478
0.0387
0.0306

Metric Units
Plunger
Plunger
Dia.
Area
mm
cm2
76
45.604
70
38.320
64
31.669
57
25.652
51
20.268
51
20.268
44
15.518
41
13.380
38
11.401
35
9.580
35
9.580
32
7.917
29
6.413
25
5.067
Kilowatts Required

L/Sec.
per
RPM
0.0174
0.0146
0.0121
0.0098
0.0077
0.0077
0.0059
0.0051
0.0043
0.0036
0.0036
0.0030
0.0024
0.0019

M3/Hr
per
RPM
0.0625
0.0526
0.0434
0.0352
0.0278
0.0278
0.0213
0.0184
0.0156
0.0131
0.0131
0.0109
0.0088
0.0069

200 RPM
Max.
Press.
PSI
672
800
968
1195
1500
1512
1975
2290
2688
3200
3200
3871
4779
5000

BPD GPM
1889
55.1
1587
46.3
1312
38.2
1063
31.0
840
24.5
840
24.5
643
18.7
555
16.2
473
13.8
397
11.6
397
11.6
328
9.6
266
7.7
210
6.1
25.0

200 RPM
Max.
Press.
kPa M3/Hr L/Sec.
4633 12.51 3.47
5514 10.51 2.92
6672
8.69
2.41
8237
7.04
1.95
10342 5.56
1.54
10425 5.56
1.54
13616 4.26
1.18
15791 3.67
1.02
18533 3.13
0.87
22063 2.63
0.73
22063 2.63
0.73
26687 2.17
0.60
32947 1.76
0.49
34474 1.39
0.39
18.6

300 RPM

BPD
2833
2381
1968
1594
1259
1259
964
832
709
596
596
492
399
315

350 RPM

GPM
82.6
69.4
57.4
46.5
36.7
36.7
28.1
24.2
20.7
17.4
17.4
14.3
11.6
9.2
37.0

BPD
3305
2777
2295
1859
1469
1469
1125
970
827
695
695
574
465
368

GPM
96.4
81.0
66.9
54.2
42.8
42.8
32.8
28.3
24.1
20.2
20.2
16.7
13.6
10.7
43.0

300 RPM

350 RPM

M3/Hr L/Sec.
18.76
5.21
15.77
4.38
13.03
3.62
10.55
2.93
8.34
2.32
8.34
2.32
6.38
1.77
5.51
1.53
4.69
1.30
3.94
1.09
3.94
1.09
3.26
0.90
2.64
0.73
2.08
0.58
27.6

M3/Hr L/Sec.
21.89
6.08
18.39
5.11
15.20
4.22
12.31
3.42
9.73
2.70
9.73
2.70
7.45
2.07
6.42
1.78
5.47
1.52
4.60
1.28
4.60
1.28
3.80
1.06
3.08
0.86
2.43
0.68
32.1

400 RPM

BPD
3777
3174
2623
2125
1679
1679
1286
1109
945
794
794
656
532
420

GPM
110.2
92.6
76.5
62.0
49.0
49.0
37.5
32.3
27.5
23.1
23.1
19.1
15.5
12.2

450 RPM

BPD
4250
3571
2951
2391
1889
1889
1446
1247
1063
893
893
738
598
473

GPM
123.9
104.1
86.1
69.7
55.1
55.1
42.2
36.4
31.0
26.0
26.0
21.5
17.4
13.8

500 RPM

BPD
4722
3968
3279
2656
2099
2099
1607
1386
1181
992
992
820
664
525

GPM
137.7
115.7
95.6
77.5
61.2
61.2
46.9
40.4
34.4
28.9
28.9
23.9
19.4
15.3

48

54

60

400 RPM

450 RPM

500 RPM

M3/Hr
25.02
21.02
17.37
14.07
11.12
11.12
8.51
7.34
6.25
5.26
5.26
4.34
3.52
2.78

L/Sec. M3/Hr L/Sec. M3/Hr L/Sec.


6.95
28.14
7.82
31.27
8.69
5.84
23.65
6.57
26.28
7.30
4.83
19.54
5.43
21.72
6.03
3.91
15.83
4.40
17.59
4.89
3.09
12.51
3.47
13.90
3.86
3.09
12.51
3.47
13.90
3.86
2.36
9.58
2.66
10.64
2.96
2.04
8.26
2.29
9.18
2.55
1.74
7.04
1.95
7.82
2.17
1.46
5.91
1.64
6.57
1.82
1.46
5.91
1.64
6.57
1.82
1.21
4.89
1.36
5.43
1.51
0.98
3.96
1.10
4.40
1.22
0.77
3.13
0.87
3.47
0.97
35.8
40
45

Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on 90% Mechanical Efficiency. Below 200 RPM External Auxiliary lubrication system required
The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own
evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that
stipulated in National Oilwell Standard Terms and Conditions of Sale.

Authorized Distributor:

www.natoil.com / customer.service@natoil.com
10000 Richmond, Houston, Texas 77042
(713)346-7500 (phone) (713)346-7366 (fax)

80T-3 Triplex Plunger Pump


5/8" x 5/16" KEYWAY

2.250
2.249

Specifications

3 7/8" (USEABLE SHAFT EXT.)

DIA.

23 9/16

SUCTION & DISCHARGE


CONNECTIONS MAY BE
MADE AT EITHER END

17 11/16

"C" / 2

5 1/2

18

"C"

5 1/2

9 3/4

7/8" DIA. HOLE THRU


4 PLACES, AS SHOWN
3.000
2.999

DIA.

5 1/8" (USEABLE SHAFT EXT.)

3/4" x 3/8" KEYWAY

1 1/2" N.P.T.
(TYP. BOTH SIDES)
DISCHARGE
"A"
"B"

1"

6 7/8

5 1/4

15 5/8

1 7/8

CENTERLINE

SUCTION
CENTERLINE

2" STD. PIPE TAP


(CRADLE DRAIN)

1 7/8

6 5/8
30

3 3/8

7 1/2

"D"

Pump Size
(maximum plunger size x stroke length in.(mm):
3 3/8 x 3 (85.7 x 76.2)
Rated bhp at 500 rpm (kw): 80 (59.65)
Rated plunger load, pounds(Kg): 6336 (2874)
Maximum discharge pressure: psi(kPa)
L model: 2016 (13,901)
M model: 4267 (29,420)
H model: 5161 (35,598)
Crankshaft extension: in.(mm)
Diameter: 3 (76.2)
Length long side: 5 1/8 (130.2)
Length short side: 5 9/16 (141.3)
Keyway (width x depth):
3/4 x 3/8 (19.1 x 9.5)
Maximum recommended sheave
in.(mm): 37.5 (952.5)
Minimum recommended sheave
in.(mm): 20 (508)
For larger sizes: Contact Customer Service
Pinion shaft extension,
if gear reducer is supplied in.(mm)
For belt or chain drive: Contact Customer Service
For direct drive: Diameter: 2 1/4 (57.2)
Length: 3 7/8 (98.4)
Keyway (width x depth):
5/8 x 5/16 (15.9 x 7.9)
Accessory gear reduction unit ratios:
2.34:1, 2.77:1, 3.03:1, 3.5:1
Oil Capacity, gallons (L)
Crankcase: 2 (7.6)
Gear Reducer: 1 (3.8)
Weight, pump only on
wood shipping skids pounds (Kg):
1195 (542.0)
Gear reducer, approximate pounds (Kg):
315 (142.88)

"E"
3/4" STD. PIPE TAP
(POWER END OIL DRAIN)

Pump Type

Flange Connections
Discharge Connection Sizes Suction Connection Sizes
80T-3L(Flanged)
2 API-2000# RJ
3 ANSI-150# FF
80T-3L(Threaded)
2 N.P.T.
3 N.P.T.
80T-3M
1 1/2 API-5000# RJ
2 1/2 ANSI-150# FF
80T-3H
1 1/4 ANSI-2500# RJ
2 1/2 ANSI-300# FF

A
4 1/8
4 1/8
4
4

Dimensions in inches (mm)


B
C
D
E
4 7/8
22 1/2
34 5/8
45 7/8
4 7/8
20 1/2
34 5/8
44 3/4
4 1/2
22 1/4
34 5/8
44 3/4
4 1/2
22 5/8
34 5/8
45 7/8

80T-3 Triplex Plunger Pump


Performance Data
PUMP

80T-3L

80T-3M

80T-3H

PUMP

80T-3L

80T-3M

80T-3H

English Units
Plunger
Plunger
BPD
Dia.
Area
per
In.
Sq. In.
RPM
3.375
8.9462
11.9503
3.250
8.2958
11.0815
3.000
7.0686
9.4423
2.750
5.9396
7.9341
2.500
4.9087
6.5571
2.250
3.9761
5.3113
2.000
3.1416
4.1966
2.000
3.1416
4.1966
1.750
2.4053
3.2130
1.625
2.0739
2.7704
1.500
1.7671
2.3606
1.375
1.4849
1.9835
1.375
1.4849
1.9835
1.250
1.2272
1.6393
Brake Horsepower Required

GPM
per
RPM
0.3486
0.3232
0.2754
0.2314
0.1912
0.1549
0.1224
0.1224
0.0937
0.0808
0.0688
0.0579
0.0579
0.0478

Metric Units
Plunger
Plunger
Dia.
Area
mm
cm2
86
57.717
83
53.521
76
45.604
70
38.320
64
31.669
57
25.652
51
20.268
51
20.268
44
15.518
41
13.380
38
11.401
35
9.580
35
9.580
32
7.917
Kilowatts Required

L/Sec.
per
RPM
0.0220
0.0204
0.0174
0.0146
0.0121
0.0098
0.0077
0.0077
0.0059
0.0051
0.0043
0.0036
0.0036
0.0030

M3/Hr
per
RPM
0.0792
0.0734
0.0625
0.0526
0.0434
0.0352
0.0278
0.0278
0.0213
0.0184
0.0156
0.0131
0.0131
0.0109

200 RPM
Max.
Press.
PSI
708
764
896
1067
1500
1594
2017
2017
2634
3055
3584
4267
4267
5161

Max.
Press.
kPa
4883
5266
6180
7355
10342
10987
13906
13906
18162
21064
24711
29420
29420
35584

BPD GPM
2391
69.7
2217
64.6
1889
55.1
1587
46.3
1312
38.2
1063
31.0
840
24.5
840
24.5
643
18.7
555
16.2
473
13.8
397
11.6
397
11.6
328
9.6
32.0

300 RPM

BPD
3586
3325
2833
2381
1968
1594
1259
1259
964
832
709
596
596
492

350 RPM

GPM
104.6
97.0
82.6
69.4
57.4
46.5
36.7
36.7
28.1
24.2
20.7
17.4
17.4
14.3
48.0

BPD
4183
3879
3305
2777
2295
1859
1469
1469
1125
970
827
695
695
574

GPM
122.0
113.1
96.4
81.0
66.9
54.2
42.8
42.8
32.8
28.3
24.1
20.2
20.2
16.7
56.0

200 RPM

300 RPM

350 RPM

M3/Hr L/Sec.
15.83 4.40
14.68 4.08
12.51 3.47
10.51 2.92
8.69
2.41
7.04
1.95
5.56
1.54
5.56
1.54
4.26
1.18
3.67
1.02
3.13
0.87
2.63
0.73
2.63
0.73
2.17
0.60
23.9

M3/Hr L/Sec.
23.75
6.60
22.02
6.12
18.76
5.21
15.77
4.38
13.03
3.62
10.55
2.93
8.34
2.32
8.34
2.32
6.38
1.77
5.51
1.53
4.69
1.30
3.94
1.09
3.94
1.09
3.26
0.90
35.8

M3/Hr L/Sec.
27.70
7.70
25.69
7.14
21.89
6.08
18.39
5.11
15.20
4.22
12.31
3.42
9.73
2.70
9.73
2.70
7.45
2.07
6.42
1.78
5.47
1.52
4.60
1.28
4.60
1.28
3.80
1.06
41.8

400 RPM

BPD
4781
4433
3777
3174
2623
2125
1679
1679
1286
1109
945
794
794
656

GPM
139.4
129.3
110.2
92.6
76.5
62.0
49.0
49.0
37.5
32.3
27.5
23.1
23.1
19.1
64

400 RPM

M3/Hr
31.66
29.36
25.02
21.02
17.37
14.07
11.12
11.12
8.51
7.34
6.25
5.26
5.26
4.34

450 RPM

BPD
5378
4987
4250
3571
2951
2391
1889
1889
1446
1247
1063
893
893
738

GPM
156.8
145.4
123.9
104.1
86.1
69.7
55.1
55.1
42.2
36.4
31.0
26.0
26.0
21.5

500 RPM

BPD
5976
5541
4722
3968
3279
2656
2099
2099
1607
1386
1181
992
992
820

GPM
174.3
161.6
137.7
115.7
95.6
77.5
61.2
61.2
46.9
40.4
34.4
28.9
28.9
23.9

72

80

450 RPM

500 RPM

L/Sec. M3/Hr L/Sec. M3/Hr L/Sec.


8.80
35.62
9.90
39.58
11.00
8.16
33.03
9.18
36.70
10.20
6.95
28.14
7.82
31.27
8.69
5.84
23.65
6.57
26.28
7.30
4.83
19.54
5.43
21.72
6.03
3.91
15.83
4.40
17.59
4.89
3.09
12.51
3.47
13.90
3.86
3.09
12.51
3.47
13.90
3.86
2.36
9.58
2.66
10.64
2.96
2.04
8.26
2.29
9.18
2.55
1.74
7.04
1.95
7.82
2.17
1.46
5.91
1.64
6.57
1.82
1.46
5.91
1.64
6.57
1.82
1.21
4.89
1.36
5.43
1.51
47.7
54
60

Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on 90% Mechanical Efficiency. For operations below 200 RPM, auxiliary lubrication system
required. Not all plunger sizes are shown. Contact National-Oilwell for additional information. 3-3/8 & 3-1/4 Plungers require spherical valves
The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own
evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that
stipulated in National Oilwell Standard Terms and Conditions of Sale.

Authorized Distributor:

www.natoil.com / customer.service@natoil.com
10000 Richmond, Houston, Texas 77042
(713)346-7500 (phone) (713)346-7366 (fax)

100T-4 Triplex Plunger Pump


5/8 "x 5/16 " KEYWAY
6 1/2

9 3/8

Specifications

2.375 DIA.
2.374

24 7/16

8 1/2

11 7/16

"C"

58 1/4

22 1/2

6 1/2

PLUNGER NO. 1

8 5/16

"C/2"

6 1/2

11 1/4

PLUNGER NO. 2

PLUNGER NO. 3

4 PUMP MOUNTING HOLES


7/8 " DIA. THRU AS SHOWN

7/8 "x 7/16 " KEYWAY


SHAFT EXTENSION
FOR DIRECT DRIVE

3.750 DIA.
3.749

1 1/2 " STD. PIPE TAP


MUD TRAP DRAIN

1 1/2 " STD. PIPE TAP


CRADLE DRAIN
TYPICAL BOTH SIDES

"B"

4 1/2

6"

9"

10 7/8

19 5/8

"A"

DISCHARGE
CENTERLINE

SUCTION
CENTERLINE

1" NPT
(POWER END OIL DRAIN)

2 7/8

Pump Size
maximum plunger size x stroke length in.(mm):
3 3/8 x 4 (85.7 x 101.6)
Rated bhp at 450 rpm (kw): 100 (75)
Rated plunger load pounds(Kg): 6595 (2991.4)
Maximum discharge pressure: psi(kPa)
L model: 1659 (11,4440)
M model: 3180 (21,939)
H model: 5000 (34,474)
Crankshaft extension: in.(mm)
Diameter: 3 3/4 (95.25)
Length long side: 8 1/2 (215.9)
Length short side: 8 5/16 (211.38)
Keyway (width x depth):
7/8 x 7/16 (22.2 x 11.1)
Maximum recommended sheave
in.(mm): 44 (1118)
Minimum recommended sheave
in.(mm): 24 (610)
For larger sizes: Contact Factory
Pinion shaft extension,
if gear reducer is supplied in.(mm)
For belt or chain drive: Contact Factory
For direct drive: Diameter: 2 3/8 (60.33)
Length: 6 1/2 (165.10)
Keyway (width x depth):
5/8 x 5/16 (15.9 x 7.9)
Accessory gear reduction unit ratios:
2.60:1, 3.15:1, 3.42:1, 3.89:1, 4.27:1
Oil Capacity gallons (L)
Crankcase: 5.5 (20.8)
Gear Reducer: 3 (11.40)
Weight, pump only on
wood shipping skids pounds (Kg):
2300 (1043.3)
Gear reducer, approximate pounds (Kg):
500 (226.8)

SUCTION & DISCHARGE


CONNECTIONS MAY BE
MADE AT EITHER END.

16 1/8
32 13/16

6"
4 3/4

"D"
2" STD. PIPE TAP
CRADLE DRAIN

33 1/8
"E"

Pump Model
100T-4L
100T-4M
100T-4H

Flange Connection
Discharge Connection Sizes Suction Connection Sizes
2 1/2 (63.5) API-2000 RJ
5 (127) ANSI-150 FF
1 1/2 (38.1) API-5000 RJ
3 (76.2) ANSI-150 FF
1 1/2 (38.1) ANSI-2500 RJ
3 (76.2) ANSI-300 FF

A
5 5/8
4 3/4
4 3/4

Dimensions in inches (mm)


B
C
D
E
6 7/8
25 1/2
41 5/8
57 3/8
5 1/4
23 3/4
40 7/8
54 3/8
5 1/4
25 1/2
40 1/2
55 3/8

100T-4 Triplex Plunger Pump


Performance Data
PUMP

100T-4L

100T-4M

100T-4H

PUMP

100T-4L

100T-4M

100T-4H

English Units
Plunger
Plunger
BPD
Dia.
Area
per
In.
Sq. In.
RPM
3.375
8.9462
15.9338
3.250
8.2958
14.7754
3.000
7.0686
12.5897
2.750
5.9396
10.5788
2.500
4.9087
8.7428
2.250
3.9761
7.0817
2.125
3.5466
6.3167
2.000
3.1416
5.5954
1.875
2.7612
4.9178
1.750
2.4053
4.2840
1.625
2.0739
3.6938
1.750
2.4053
4.2840
1.625
2.0739
3.6938
1.500
1.7671
3.1474
1.375
1.4849
2.6447
1.250
1.2272
2.1857
Brake Horsepower Required

GPM
per
RPM
0.4647
0.4309
0.3672
0.3085
0.2550
0.2065
0.1842
0.1632
0.1434
0.1249
0.1077
0.1249
0.1077
0.0918
0.0771
0.0637

200 RPM

Metric Units
Plunger
Plunger
Dia.
Area
mm
cm2
86
57.717
83
53.521
76
45.604
70
38.320
64
31.669
57
25.652
54
22.881
51
20.268
48
17.814
44
15.518
41
13.380
44
15.518
41
13.380
38
11.401
35
9.580
32
7.917
Kilowatts Required

L/Sec.
per
RPM
0.0293
0.0272
0.0232
0.0195
0.0161
0.0130
0.0116
0.0103
0.0090
0.0079
0.0068
0.0079
0.0068
0.0058
0.0049
0.0040

Max.
Press.
PSI
737
795
933
1110
1500
1659
1860
2099
2388
2742
3180
2742
3180
3732
4441
5000

BPD GPM
3187
92.9
2956
86.2
2518
73.4
2116
61.7
1749
51.0
1417
41.3
1264
36.8
1120
32.6
984
28.7
857
25.0
739
21.5
857
25.0
739
21.5
630
18.4
529
15.4
438
12.7
45.0

200 RPM
M3/Hr
per
RPM
0.1055
0.0979
0.0834
0.0701
0.0579
0.0469
0.0418
0.0371
0.0326
0.0284
0.0245
0.0284
0.0245
0.0208
0.0175
0.0145

Max.
Press.
kPa
5083
5481
6433
7656
10342
11436
12821
14474
16468
18905
21925
18905
21925
25731
30623
34474

M3/Hr L/Sec.
21.11 5.86
19.57 5.44
16.68 4.63
14.01 3.89
11.58 3.22
9.38
2.61
8.37
2.32
7.41
2.06
6.51
1.81
5.68
1.58
4.89
1.36
5.68
1.58
4.89
1.36
4.17
1.16
106.37 3.50
48.26 87.91
33.6

250 RPM

BPD
3984
3694
3148
2645
2186
1771
1580
1399
1230
1071
924
1071
924
787
662
547

GPM
116.2
107.7
91.8
77.1
63.7
51.6
46.1
40.8
35.9
31.2
26.9
31.2
26.9
22.9
19.3
15.9
56.0

250 RPM

300 RPM

BPD
4781
4433
3777
3174
2623
2125
1896
1679
1476
1286
1109
1286
1109
945
794
656

GPM
139.4
129.3
110.2
92.6
76.5
62.0
55.3
49.0
43.0
37.5
32.3
37.5
32.3
27.5
23.1
19.1
67.0

300 RPM

350 RPM

BPD
5577
5172
4407
3703
3060
2479
2211
1959
1722
1500
1293
1500
1293
1102
926
765

GPM
162.7
150.8
128.5
108.0
89.2
72.3
64.5
57.1
50.2
43.7
37.7
43.7
37.7
32.1
27.0
22.3
78

350 RPM

400 RPM

BPD
6374
5911
5036
4232
3498
2833
2527
2239
1968
1714
1478
1714
1478
1259
1058
875

GPM
185.9
172.4
146.9
123.4
102.0
82.6
73.7
65.3
57.4
50.0
43.1
50.0
43.1
36.7
30.9
25.5
89

400 RPM

450 RPM

BPD
7171
6649
5666
4761
3935
3187
2843
2518
2214
1928
1663
1928
1663
1417
1191
984

GPM
209.1
193.9
165.2
138.8
114.7
92.9
82.9
73.4
64.5
56.2
48.5
56.2
48.5
41.3
34.7
28.7
100

450 RPM

M3/Hr L/Sec. M3/Hr L/Sec. M3/Hr L/Sec. M3/Hr L/Sec. M3/Hr L/Sec.
26.39
7.33
31.66
8.80
36.94
10.26 42.22
11.73 47.49
13.19
24.47
6.80
29.36
8.16
34.25
9.52
39.15
10.88 44.04
12.23
20.85
5.79
25.02
6.95
29.19
8.11
33.36
9.27
37.53
10.42
17.52
4.87
21.02
5.84
24.53
6.81
28.03
7.79
31.53
8.76
14.48
4.02
17.37
4.83
20.27
5.63
23.16
6.44
26.06
7.24
11.73
3.26
14.07
3.91
16.42
4.56
18.76
5.21
21.11
5.86
10.46
2.91
12.55
3.49
14.64
4.07
16.74
4.65
18.83
5.23
9.27
2.57
11.12
3.09
12.97
3.60
14.83
4.12
16.68
4.63
8.14
2.26
9.77
2.71
11.40
3.17
13.03
3.62
14.66
4.07
7.09
1.97
8.51
2.36
9.93
2.76
11.35
3.15
12.77
3.55
6.12
1.70
7.34
2.04
8.56
2.38
9.79
2.72
11.01
3.06
7.09
1.97
8.51
2.36
9.93
2.76
11.35
3.15
12.77
3.55
6.12
1.70
7.34
2.04
8.56
2.38
9.79
2.72
11.01
3.06
5.21
1.45
6.25
1.74
7.30
2.03
8.34
2.32
9.38
2.61
132.96 4.38
159.55
5.26
186.15
6.13 212.74
7.01 239.33
7.88
60.33 109.89 72.40 131.86 84.46 153.84 96.53 175.82 108.59 197.79
41.8
50.0
58.0
66
75

Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on 90% Mechanical Efficiency. For operations below 200 RPM, auxiliary lubrication system
required. Not all plunger sizes are shown. Contact National-Oilwell for additional information.
The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own
evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that
stipulated in National Oilwell Standard Terms and Conditions of Sale.

Authorized Distributor:

www.natoil.com / customer.service@natoil.com
10000 Richmond, Houston, Texas 77042
(713)346-7500 (phone) (713)346-7366 (fax)

101T-4 Triplex Plunger Pump


Specifications

DIRECTION OF ROTATION
18.25

14.44
8.00
16.00

6.00
TYP
12.19

19.50
.75
TYP
4 PLACES

.750 X .375 KEYWAY


5.125 LONG

3.000
2.999

"101T-4H" ONLY

10.33

F
A

10.00

1.00
TYP
5.25
8.81

21.75
24.25
D
E

Pump Model
101T-4L
101T-4M
101T-4H

Flange Connections
Discharge Connection Sizes Suction Connection Sizes
3 - 600# ANSI FF
6 - 150# ANSI FF
2 - 1500# ANSI FF
4 - 300# ANSI FF
2 - 2500# ANSI RJ
3 - 2500# ANSI RJ

D
E

A
4 5/8
5 1/16
5 1/8

33.38

Pump Size:
maximum plunger size x stroke length, in.(mm):
3.375 x 4.500 (85.725 x 114.3)
Rated BHP (kW) at 400 RPM: 100 (75)
Rated plunger load, pounds (kg): 6600 (2994)
Maximum discharge pressure: psi (kPa)
L model: 1220 (8408)
M model: 2744 (18919)
H model: 5378 (37081)
Crankshaft extension:
Diameter, in.(mm): 3.000 (95.25)
Length, in.(mm): 5.13 (130.3)
Keyway width x depth, in.(mm):
3/4 x 3/8 (19.1 x 9.5)
Maximum recommended sheave diameter,
in.(mm): 50 (1270)
For larger sizes: Contact Factory
Pinion shaft extension,
if gear reducer is supplied, in.(mm)
For belt or chain drive: N/A
For direct drive: Diameter: 2.000 (50.8)
Length: 4.25 (108.0)
Keyway width x depth:
1/2 x 1/4 (12.70 x 6.35)
Accessory gear reduction unit:
3.00:1, 3.12:1, 3.23:1, 3.36:1, 3.49:1,
3.62:1, 3.78:1, 3.94:1, 4.11:1, 4.29:1,
4.48:1, 4.69:1, 4.93:1, 5.17:1
Oil Capacity, gallons (L)
Crankcase: 6 (22.71)
Gear Reducer - varies with ratio:
1.25 to 1.50 (4.73 to 5.68)
Weight, pump only on
wood shipping skids, pounds (kg)
L model: 1740 (649.4)
M model: 1600 (597.2)
H model: 1820 (679.3)
Standard Materials for Fluid Ends:
L model
Cast Duplex Stainelss Steel
Cast Nickel-Aluminium-Bronze
Forged/Plate Carbon Steel
M model
Cast Duplex Stainless Steel
Cast Nickel-Aluminium-Bronze
Forged/Plate Carbon Steel
H model
Forged/Plate Carbon Steel

Dimensions (Inches)
B
C
D
E
7 7/8
21
33 3/4
48 3/8
6 3/16
21
33 3/8
47 9/16
6 1/8
30 1/8
36 3/4
52 7/16

F
9 3/8
9
11 7/8

101T-4 Triplex Plunger Pump


Performance Data
PUMP

101T-4L
(T100-4)

101T-4M
(T100-3)

101T-4H
(T100-2)

PUMP

101T-4L
(T100-4)

101T-4M
(T100-3)

101T-4H
(T100-2)

English Units
Plunger
Plunger
BPD
Dia.
Area
per
In.
Sq. In.
RPM
3.375
8.9462
17.9255
3.250
8.2958
16.6223
3.125
7.6699
15.3682
3.000
7.0686
14.1634
2.875
6.4918
13.0077
2.750
5.9396
11.9012
2.625
5.4119
10.8438
2.500
4.9087
9.8357
2.375
4.4301
8.8767
2.250
3.9761
7.9669
2.125
3.5466
7.1063
2.000
3.1416
6.2948
1.875
2.7612
5.5326
1.750
2.4053
4.8195
1.625
2.0739
4.1556
1.500
1.7671
3.5408
1.375
1.4849
2.9753
1.250
1.2272
2.4589
Brake Horsepower Required

GPM
per
RPM
0.5228
0.4848
0.4482
0.4131
0.3794
0.3471
0.3163
0.2869
0.2589
0.2324
0.2073
0.1836
0.1614
0.1406
0.1212
0.1033
0.0868
0.0717

Metric Units
Plunger
Plunger
Dia.
Area
mm
cm2
86
57.717
83
53.521
79
49.483
76
45.604
73
41.883
70
38.320
67
34.915
64
31.669
60
28.581
57
25.652
54
22.881
51
20.268
48
17.814
44
15.518
41
13.380
38
11.401
35
9.580
32
7.917
Kilowatts Required

L/Sec.
per
RPM
0.0330
0.0306
0.0283
0.0261
0.0239
0.0219
0.0200
0.0181
0.0163
0.0147
0.0131
0.0116
0.0102
0.0089
0.0076
0.0065
0.0055
0.0045

M3/Hr
per
RPM
0.1187
0.1101
0.1018
0.0938
0.0862
0.0788
0.0718
0.0651
0.0588
0.0528
0.0471
0.0417
0.0366
0.0319
0.0275
0.0235
0.0197
0.0163

50 RPM
Max.
Press.
PSI
738
796
861
934
1017
1111
1220
1345
1490
1660
1861
2101
2390
2744
3182
3735
4445
5378

BPD
897
832
769
709
651
596
543
492
444
399
356
315
277
241
208
178
149
123

GPM
26.1
24.2
22.4
20.7
19.0
17.4
15.8
14.3
12.9
11.6
10.4
9.2
8.1
7.0
6.1
5.2
4.3
3.6
13

150 RPM

BPD
2689
2494
2306
2125
1952
1786
1627
1476
1332
1196
1066
945
830
723
624
532
447
369

250 RPM

GPM
78.4
72.7
67.2
62.0
56.9
52.1
47.4
43.0
38.8
34.9
31.1
27.5
24.2
21.1
18.2
15.5
13.0
10.8

BPD
4482
4156
3843
3541
3252
2976
2711
2459
2220
1992
1777
1574
1384
1205
1039
886
744
615

38

50 RPM
150 RPM
Max.
Press.
kPa M3/Hr L/Sec. M3/Hr L/Sec.
5087
5.9
1.6
17.8
4.9
5485
5.5
1.5
16.5
4.6
5933
5.1
1.4
15.3
4.2
6438
4.7
1.3
14.1
3.9
7010
4.3
1.2
12.9
3.6
7661
3.9
1.1
11.8
3.3
8408
3.6
1.0
10.8
3.0
9270
3.3
0.90
9.8
2.7
10272
2.9
0.82
8.8
2.5
11445
2.6
0.73
7.9
2.2
12831
2.4
0.65
7.1
2.0
14485
2.1
0.58
6.3
1.7
16481
1.8
0.51
5.5
1.5
18919
1.6
0.44
4.8
1.3
21942
1.4
0.38
4.1
1.1
25751
1.2
0.33
3.5
1.0
30646
1.0
0.27
3.0
0.82
37081
0.8
0.23
2.4
0.68
10
28

GPM
130.7
121.2
112.1
103.3
94.8
86.8
79.1
71.7
64.7
58.1
51.8
45.9
40.3
35.1
30.3
25.8
21.7
17.9

300 RPM

BPD
5378
4987
4611
4250
3903
3571
3254
2951
2664
2391
2132
1889
1660
1446
1247
1063
893
738

GPM
156.8
145.4
134.5
123.9
113.8
104.1
94.9
86.1
77.7
69.7
62.2
55.1
48.4
42.2
36.4
31.0
26.0
21.5

350 RPM

BPD
6274
5818
5379
4958
4553
4166
3796
3443
3107
2789
2488
2204
1937
1687
1455
1240
1042
861

GPM
183.0
169.7
156.9
144.6
132.8
121.5
110.7
100.4
90.6
81.3
72.5
64.3
56.5
49.2
42.4
36.1
30.4
25.1

63

75

88

250 RPM

300 RPM

350 RPM

M3/Hr
29.7
27.5
25.4
23.5
21.5
19.7
18.0
16.3
14.7
13.2
11.8
10.4
9.2
8.0
6.9
5.9
4.9
4.1

L/Sec.
8.2
7.6
7.1
6.5
6.0
5.5
5.0
4.5
4.1
3.7
3.3
2.9
2.5
2.2
1.9
1.6
1.4
1.1

M3/Hr
35.6
33.0
30.5
28.1
25.8
23.6
21.5
19.5
17.6
15.8
14.1
12.5
11.0
9.6
8.3
7.0
5.9
4.9

47

400 RPM

BPD
7171
6649
6148
5666
5204
4761
4338
3935
3551
3187
2843
2518
2214
1928
1663
1417
1191
984

GPM
209.1
193.9
179.3
165.2
151.8
138.8
126.5
114.7
103.6
92.9
82.9
73.4
64.5
56.2
48.5
41.3
34.7
28.7
100

400 RPM

L/Sec. M3/Hr L/Sec. M3/Hr L/Sec.


9.9
41.6
11.5
47.5
13.2
9.2
38.5
10.7
44.0
12.2
8.5
35.6
9.9
40.7
11.3
7.8
32.8
9.1
37.5
10.4
7.2
30.2
8.4
34.5
9.6
6.6
27.6
7.7
31.5
8.8
6.0
25.1
7.0
28.7
8.0
5.4
22.8
6.3
26.1
7.2
4.9
20.6
5.7
23.5
6.5
4.4
18.5
5.1
21.1
5.9
3.9
16.5
4.6
18.8
5.2
3.5
14.6
4.1
16.7
4.6
3.1
12.8
3.6
14.7
4.1
2.7
11.2
3.1
12.8
3.5
2.3
9.6
2.7
11.0
3.1
2.0
8.2
2.3
9.4
2.6
1.6
6.9
1.9
7.9
2.2
1.4
5.7
1.6
6.5
1.8
56
65
75

Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on 90% Mechanical Efficiency.
The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own
evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that
stipulated in National Oilwell Standard Terms and Conditions of Sale.

Authorized Distributor:

www.natoil.com / customer.service@natoil.com
10000 Richmond, Houston, Texas 77042
(713)346-7500 (phone) (713)346-7366 (fax)

103Q-3 Quintuplex Plunger Pump


Specifications

18.63

C/2
10.50

21.00

15.94

5.50
.75
TYP
4 PLACES

2.500
2.499

.625 x .313 KEYWAY


5.250 LONG

DISCHARGE
CONNECTION

19.13
.75

8.75

.75
4.25
8.00

SUCTION
CONNECTION

18.88
D

Pump Model
103Q-3L
103Q-3M
103Q-3MS
103Q-3H

Flange Connections
Discharge Connection Sizes Suction Connection Sizes
3 (76.2)-600# ANSI FF
6 (152.4)-150# ANSI FF
2 (50.8)-1500# ANSI FF
3 (76.2)-300# ANSI FF
2 (50.8) NPT-11 1/2 THDS
3 (76.2) NPT-11 1/2 THDS
1 (25.4) NPT-11 1/2 THDS
1 1/2 (38.1) NPT-11 1/2 THDS

A
5
3 7/16
4 9/16
3 7/8

Pump Size:
maximum plunger size x stroke length, in.(mm):
3.000 x 3.500 (76.2 x 88.9)
Rated BHP (kW) at 435 RPM: 102 (76)
Rated plunger load, pounds (kg): 4760 (2159)
Maximum discharge pressure: psi (kPa)
L model: 970 (6686)
M model: 2295 (15825)
MS model: 4789 (33017)
H model: 10000 (68948)
Crankshaft extension:
Diameter, in.(mm): 2.500 (63.5)
Length : 5.250 (133.35)
Keyway (width x depth):
5/8 x 5/16 (15.875 x 7.938)
Maximum recommended sheave
in.(mm): 38 (965.2)
For larger sizes: Contact Factory
Pinion shaft extension,
if gear reducer is supplied, in.(mm)
For belt or chain drive: N/A
For direct drive: Diameter: 2.000 (50.8)
Length: 4.250 (108.0)
Keyway width x depth:
1/2 x 1/4 (12.70 x 6.35)
Accessory gear reduction unit:
3.00:1, 3.12:1, 3.23:1, 3.36:1, 3.49:1,
3.62:1, 3.78:1, 3.94:1, 4.11:1, 4.29:1,
4.48:1, 4.69:1, 4.93:1, 5.17:1
Oil Capacity, gallons (L)
Crankcase: 5 (18.93)
Gear Reducer - varies with ratio:
1.25 to 1.50 (4.73 to 5.68)
Weight, pump only on
wood shipping skids, pounds (kg)
L model: 1620 (735)
M model: 1450 (658)
MS model: 1600 (726)
H model: 1700 (771)
Standard Materials for Fluid Ends:
L model
Cast Ductile Iron
Cast Nickel-Aluminum-Bronze
Cast Duplex Stainless Steel
Forged/Plate Carbon Steel
M model
Cast Ductile Iron,
Cast Nickel-Aluminum-Bronze
Cast Duplex Stainless Steel
Forged/Plate Carbon Steel
MS model
Forged Nickel-Aluminum-Bronze
Forged/Plate Carbon Steel
Forged 316 Stainless Steel
H model
Forged 15-5 Stainless Steel

Dimensions (Inches)
B
C
D
7 1/4
29
28
5 3/4
30
27 3/16
5 3/4
26 1/2
26 7/8
4 3/8
28
25 3/4

E
41 5/8
40 7/8
40 1/8
39 7/8

F
9 7/8
8 1/8
8 7/8
7 3/4

103Q-3 Quintuplex Plunger Pump


Performance Data
PUMP

103Q-3L
(Q3115AL)

103Q-3M
(Q3115AM)

103Q-3MS
(Q3115MS)

103Q-3H
(Q3115H)

PUMP

103Q-3L
(Q3115AL)

103Q-3M
(Q3115AM)

103Q-3MS
(Q3115MS)

103Q-H
(Q3115H)

English Units
Plunger
Plunger
BPD
Dia.
Area
per
In.
Sq. In.
RPM
3.000
7.0686
18.3599
2.875
6.4918
16.8618
2.750
5.9396
15.4274
2.625
5.4119
14.0568
2.500
4.9087
12.7500
2.500
4.9087
12.7500
2.375
4.4301
11.5068
2.250
3.9761
10.3275
2.125
3.5466
9.2118
2.000
3.1416
8.1600
1.875
2.7612
7.1718
1.750
2.4053
6.2475
1.625
2.0739
5.3869
1.500
1.7671
4.5900
1.375
1.4849
3.8569
1.250
1.2272
3.1875
1.125
0.9940
2.5819
1.000
0.7854
2.0400
0.875
0.6013
1.5619
0.750
0.4418
1.1475
Brake Horsepower Required

GPM
per
RPM
0.5355
0.4918
0.4500
0.4100
0.3719
0.3719
0.3356
0.3012
0.2687
0.2380
0.2092
0.1822
0.1571
0.1339
0.1125
0.0930
0.0753
0.0595
0.0456
0.0335

Metric Units
Plunger
Plunger
Dia.
Area
mm
cm2
76
45.604
73
41.883
70
38.320
67
34.915
64
31.669
64
31.669
60
28.581
57
25.652
54
22.881
51
20.268
48
17.814
44
15.518
41
13.380
38
11.401
35
9.580
32
7.917
29
6.413
25
5.067
22
3.879
19
2.850
Kilowatts Required

L/Sec.
per
RPM
0.0338
0.0310
0.0284
0.0259
0.0235
0.0235
0.0212
0.0190
0.0170
0.0150
0.0132
0.0115
0.0099
0.0084
0.0071
0.0059
0.0048
0.0038
0.0029
0.0021

M3/Hr
per
RPM
0.1216
0.1117
0.1022
0.0931
0.0845
0.0845
0.0762
0.0684
0.0610
0.0540
0.0475
0.0414
0.0357
0.0304
0.0255
0.0211
0.0171
0.0135
0.0103
0.0076

50 RPM
Max.
Press.
PSI
673
733
801
880
970
970
1074
1197
1342
1515
1724
1979
2295
2694
3206
3879
4789
6061
7916
10000

BPD
918
844
772
703
638
638
576
517
461
408
359
313
270
230
193
160
130
102
79
58

GPM
26.8
24.6
22.5
20.5
18.6
18.6
16.8
15.1
13.4
11.9
10.5
9.1
7.9
6.7
5.6
4.6
3.8
3.0
2.3
1.7
12

150 RPM

BPD
2754
2530
2315
2109
1913
1913
1727
1550
1382
1224
1076
938
809
689
579
479
388
306
235
173

250 RPM

GPM
80.3
73.8
67.5
61.5
55.8
55.8
50.3
45.2
40.3
35.7
31.4
27.3
23.6
20.1
16.9
13.9
11.3
8.9
6.8
5.0

BPD
4590
4216
3857
3515
3188
3188
2877
2582
2303
2040
1793
1562
1347
1148
965
797
646
510
391
287

35

50 RPM
150 RPM
Max.
Press.
kPa M3/Hr L/Sec. M3/Hr L/Sec.
4643
6.1
1.69
18.2
5.07
5055
5.6
1.55
16.8
4.65
5526
5.1
1.42
15.3
4.26
6064
4.7
1.29
14.0
3.88
6686
4.2
1.17
12.7
3.52
6686
4.2
1.17
12.7
3.52
7408
3.8
1.06
11.4
3.18
8254
3.4
0.95
10.3
2.85
9254
3.1
0.85
9.2
2.54
10447
2.7
0.75
8.1
2.25
11886
2.4
0.66
7.1
1.98
13645
2.1
0.57
6.2
1.72
15825
1.8
0.50
5.4
1.49
18572
1.5
0.42
4.6
1.27
22102
1.3
0.35
3.8
1.06
26744
1.1
0.29
3.2
0.88
33017
0.9
0.24
2.6
0.71
41787
0.7
0.19
2.0
0.56
54579
0.5
0.14
1.6
0.43
68948
0.4
0.11
1.1
0.32
9
26

GPM
133.9
123.0
112.5
102.5
93.0
93.0
83.9
75.3
67.2
59.5
52.3
45.6
39.3
33.5
28.1
23.2
18.8
14.9
11.4
8.4

300 RPM

BPD
5508
5059
4629
4218
3825
3825
3453
3099
2764
2448
2152
1875
1617
1377
1158
957
775
612
469
345

GPM
160.6
147.5
135.0
123.0
111.6
111.6
100.7
90.4
80.6
71.4
62.8
54.7
47.1
40.2
33.7
27.9
22.6
17.8
13.7
10.0

350 RPM

BPD
6426
5902
5400
4920
4463
4463
4028
3615
3225
2856
2511
2187
1886
1607
1350
1116
904
714
547
402

GPM
187.4
172.1
157.5
143.5
130.2
130.2
117.5
105.4
94.0
83.3
73.2
63.8
55.0
46.9
39.4
32.5
26.4
20.8
15.9
11.7

59

70

82

250 RPM

300 RPM

350 RPM

M3/Hr
30.4
27.9
25.5
23.3
21.1
21.1
19.1
17.1
15.3
13.5
11.9
10.3
8.9
7.6
6.4
5.3
4.3
3.4
2.6
1.9

L/Sec.
8.45
7.76
7.10
6.47
5.87
5.87
5.29
4.75
4.24
3.75
3.30
2.87
2.48
2.11
1.77
1.47
1.19
0.94
0.72
0.53
44

M3/Hr
36.5
33.5
30.7
27.9
25.3
25.3
22.9
20.5
18.3
16.2
14.3
12.4
10.7
9.1
7.7
6.3
5.1
4.1
3.1
2.3

435 RPM

BPD
7987
7335
6711
6115
5547
5547
5006
4493
4008
3550
3120
2718
2344
1997
1678
1387
1124
888
680
500

GPM
232.9
213.9
195.7
178.3
161.8
161.8
146.0
131.0
116.9
103.5
91.0
79.3
68.3
58.2
48.9
40.4
32.8
25.9
19.8
14.6
102

435 RPM

L/Sec. M3/Hr L/Sec. M3/Hr L/Sec.


10.14
42.6
11.82
52.9
14.70
9.31
39.1
10.86
48.6
13.50
8.52
35.8
9.94
44.5
12.35
7.76
32.6
9.05
40.5
11.25
7.04
29.6
8.21
36.7
10.21
7.04
29.6
8.21
36.7
10.21
6.35
26.7
7.41
33.2
9.21
5.70
23.9
6.65
29.8
8.27
5.09
21.4
5.93
26.5
7.37
4.50
18.9
5.26
23.5
6.53
3.96
16.6
4.62
20.7
5.74
3.45
14.5
4.02
18.0
5.00
2.97
12.5
3.47
15.5
4.31
2.53
10.6
2.96
13.2
3.67
2.13
8.9
2.48
11.1
3.09
1.76
7.4
2.05
9.2
2.55
1.43
6.0
1.66
7.4
2.07
1.13
4.7
1.31
5.9
1.63
0.86
3.6
1.01
4.5
1.25
0.63
2.7
0.74
3.3
0.92
52
61
76

Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on 90% Mechanical Efficiency.
The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own
evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that
stipulated in National Oilwell Standard Terms and Conditions of Sale.

Authorized Distributor:

www.natoil.com / customer.service@natoil.com
10000 Richmond, Houston, Texas 77042
(713)346-7500 (phone) (713)346-7366 (fax)

110Q-3 Quintuplex Plunger Pump


INTERNAL LUBE PUMP

Specifications

PRESSURE GAUGE

21.75

C/2
10.50

21.00

15.94

8.31

.75
TYP
4 PLACES

.750 x .375 KEYWAY


6.250 LONG

3.250
3.249

DISCHARGE
CONNECTION

6.63
19.13
.75

8.75

15.50
.75
4.25
8.00

SUCTION
CONNECTION

18.88
D
E

Pump Model
110Q-3L
110Q-3M
110Q-3MS
110Q-3H

Flange Connections
Discharge Connection Sizes Suction Connection Sizes
3 (76.2)-600# ANSI FF
6 (152.4)-150# ANSI FF
2 (50.8)-1500# ANSI FF
3 (76.2)-300# ANSI FF
2 (50.8) NPT-11 1/2 THDS
3 (76.2) NPT-11 1/2 THDS
1 (25.4) NPT-11 1/2 THDS
1 1/2 (38.1) NPT-11 1/2 THDS

A
5
3 7/16
4 9/16
3 7/8

Pump Size:
maximum plunger size x stroke length, in.(mm):
3.000 x 3.500 (76.2 x 88.9)
Rated BHP (kW) at 440 RPM: 110 (82)
Rated plunger load, pounds (kg): 5090 (2309)
Maximum discharge pressure: psi (kPa)
L model: 1037 (7149)
M model: 2454 (16922)
MS model: 5121 (35306)
H model: 10000 (68948)
Crankshaft extension:
Diameter, in.(mm): 3.250 (82.55)
Length, in.(mm): 8.31 (211.1)
Keyway width x depth, in.(mm):
3/4 x 3/8 (19.05 x 9.525)
Maximum recommended sheave diameter,
in.(mm): 38 (965.2)
For larger sizes: Contact Factory
Pinion shaft extension,
if gear reducer is supplied, in.(mm)
For belt or chain drive: N/A
For direct drive: Diameter: 2.000 (50.8)
Length: 4.250 (108.0)
Keyway width x depth:
1/2 x 1/4 (12.70 x 6.35)
Accessory gear reduction unit:
3.00:1, 3.12:1, 3.23:1, 3.36:1, 3.49:1,
3.62:1, 3.78:1,3.94:1, 4.11:1, 4.29:1,
4.48:1, 4.69:1, 4.93:1, 5.17:1
Oil Capacity, gallons (L)
Crankcase: 5 (18.93)
Gear Reducer - varies with ratio:
1.25 to 1.50 (4.73 to 5.68)
Weight, pump only on
wood shipping skids, pounds (kg)
L model: 1670 (757)
M model: 1500 (680)
MS model: 1650 (748)
H model: 1750 (794)
Standard Materials for Fluid Ends:
L model
Cast Ductile Iron
Cast Nickel-Aluminum-Bronze
Cast Duplex Stainless Steel
Cast/Forged/Plate Carbon Steel
M model
Cast Ductile Iron
Cast Nickel-Aluminum-Bronze
Cast Duplex Stainless Steel
Cast/Forged/Plate Carbon Steel
MS model
Forged Nickel-Aluminum-Bronze
Forged 15-5 Stainless Steel
Cast/Forged/Plate Carbon Steel
H model
Forged Carbon Steel
Forged 15-5 Stainless Steel

Dimensions (Inches)
B
C
D
7 1/4
29
28
5 3/4
30
27 3/16
5 3/4
26 1/2
26 7/8
4 3/8
28
25 3/4

E
41 5/8
40 7/8
40 1/8
39 7/8

F
9 7/8
8 1/8
8 7/8
7 3/4

110Q-3 Quintuplex Plunger Pump


Performance Data
PUMP

110Q-3L
(HP125AL)

110Q-3M
(HP125AM)

110Q-3MS
(HP125MS)

110Q-H
(HP125H)

PUMP

110Q-3L
(HP125AL)

110Q-3M
(HP125AM)

110Q-3MS
(HP125MS)

110Q-H
(HP125H)

English Units
Plunger
Plunger
BPD
Dia.
Area
per
In.
Sq. In.
RPM
3.000
7.0686
18.3599
2.875
6.4918
16.8618
2.750
5.9396
15.4274
2.625
5.4119
14.0568
2.500
4.9087
12.7500
2.500
4.9087
12.7500
2.375
4.4301
11.5068
2.250
3.9761
10.3275
2.125
3.5466
9.2118
2.000
3.1416
8.1600
1.875
2.7612
7.1718
1.750
2.4053
6.2475
1.625
2.0739
5.3869
1.500
1.7671
4.5900
1.375
1.4849
3.8569
1.250
1.2272
3.1875
1.125
0.9940
2.5819
1.000
0.7854
2.0400
0.875
0.6013
1.5619
0.750
0.4418
1.1475
Brake Horsepower Required

GPM
per
RPM
0.5355
0.4918
0.4500
0.4100
0.3719
0.3719
0.3356
0.3012
0.2687
0.2380
0.2092
0.1822
0.1571
0.1339
0.1125
0.0930
0.0753
0.0595
0.0456
0.0335

Metric Units
Plunger
Plunger
Dia.
Area
mm
cm2
76
45.604
73
41.883
70
38.320
67
34.915
64
31.669
64
31.669
60
28.581
57
25.652
54
22.881
51
20.268
48
17.814
44
15.518
41
13.380
38
11.401
35
9.580
32
7.917
29
6.413
25
5.067
22
3.879
19
2.850
Kilowatts Required

L/Sec.
per
RPM
0.0338
0.0310
0.0284
0.0259
0.0235
0.0235
0.0212
0.0190
0.0170
0.0150
0.0132
0.0115
0.0099
0.0084
0.0071
0.0059
0.0048
0.0038
0.0029
0.0021

M3/Hr
per
RPM
0.1216
0.1117
0.1022
0.0931
0.0845
0.0845
0.0762
0.0684
0.0610
0.0540
0.0475
0.0414
0.0357
0.0304
0.0255
0.0211
0.0171
0.0135
0.0103
0.0076

100 * RPM
Max.
Press.
PSI
720
784
857
941
1037
1037
1149
1280
1435
1620
1843
2116
2454
2880
3428
4148
5121
6481
8465
10000

BPD
1836
1687
1543
1406
1275
1275
1151
1033
922
816
718
625
539
459
386
319
259
204
157
115

GPM
53.5
49.2
45.0
41.0
37.2
37.2
33.6
30.1
26.9
23.8
20.9
18.2
15.7
13.4
11.2
9.3
7.5
5.9
4.6
3.3
25

200 RPM

BPD
3672
3373
3086
2812
2550
2550
2302
2066
1843
1632
1435
1250
1078
918
772
638
517
408
313
230

250 RPM

GPM
107.1
98.4
90.0
82.0
74.4
74.4
67.1
60.2
53.7
47.6
41.8
36.4
31.4
26.8
22.5
18.6
15.1
11.9
9.1
6.7

BPD
4590
4216
3857
3515
3188
3188
2877
2582
2303
2040
1793
1562
1347
1148
965
797
646
510
391
287

50

GPM
133.9
123.0
112.5
102.5
93.0
93.0
83.9
75.3
67.2
59.5
52.3
45.6
39.3
33.5
28.1
23.2
18.8
14.9
11.4
8.4

300 RPM

BPD
5508
5059
4629
4218
3825
3825
3453
3099
2764
2448
2152
1875
1617
1377
1158
957
775
612
469
345

63

100 * RPM
200 RPM
Max.
Press.
kPa M3/Hr L/Sec. M3/Hr L/Sec.
4965
12.2
3.4
24.3
6.8
5406
11.2
3.1
22.3
6.2
5909
10.2
2.8
20.4
5.7
6485
9.3
2.6
18.6
5.2
7149
8.4
2.3
16.9
4.7
7149
8.4
2.3
16.9
4.7
7922
7.6
2.1
15.2
4.2
8826
6.8
1.9
13.7
3.8
9895
6.1
1.7
12.2
3.4
11171
5.4
1.5
10.8
3.0
12710
4.8
1.3
9.5
2.6
14591
4.1
1.1
8.3
2.3
16922
3.6
1.0
7.1
2.0
19859
3.0
0.8
6.1
1.7
23634
2.6
0.7
5.1
1.4
28598
2.1
0.6
4.2
1.2
35306
1.7
0.5
3.4
1.0
44684
1.4
0.4
2.7
0.8
58362
1.0
0.3
2.1
0.6
68948
0.8
0.2
1.5
0.4
19
37

250 RPM

M3/Hr
30.4
27.9
25.5
23.3
21.1
21.1
19.1
17.1
15.3
13.5
11.9
10.3
8.9
7.6
6.4
5.3
4.3
3.4
2.6
1.9

L/Sec.
8.4
7.8
7.1
6.5
5.9
5.9
5.3
4.8
4.2
3.8
3.3
2.9
2.5
2.1
1.8
1.5
1.2
0.9
0.7
0.5
47

GPM
160.6
147.5
135.0
123.0
111.6
111.6
100.7
90.4
80.6
71.4
62.8
54.7
47.1
40.2
33.7
27.9
22.6
17.8
13.7
10.0
75

300 RPM

M3/Hr
36.5
33.5
30.7
27.9
25.3
25.3
22.9
20.5
18.3
16.2
14.3
12.4
10.7
9.1
7.7
6.3
5.1
4.1
3.1
2.3

350 RPM

BPD
6426
5902
5400
4920
4463
4463
4028
3615
3225
2856
2511
2187
1886
1607
1350
1116
904
714
547
402

GPM
187.4
172.1
157.5
143.5
130.2
130.2
117.5
105.4
94.0
83.3
73.2
63.8
55.0
46.9
39.4
32.5
26.4
20.8
15.9
11.7

440 RPM

BPD
8079
7420
6789
6186
5610
5610
5064
4545
4054
3591
3156
2749
2371
2020
1698
1403
1137
898
688
505

GPM
235.6
216.4
198.0
180.4
163.6
163.6
147.7
132.5
118.2
104.7
92.0
80.2
69.1
58.9
49.5
40.9
33.1
26.2
20.0
14.7

87

110

350 RPM

440 RPM

L/Sec. M3/Hr L/Sec. M3/Hr L/Sec.


10.1
42.6
11.8
53.5
14.9
9.3
39.1
10.9
49.1
13.7
8.5
35.8
9.9
45.0
12.5
7.8
32.6
9.1
41.0
11.4
7.0
29.6
8.2
37.2
10.3
7.0
29.6
8.2
37.2
10.3
6.4
26.7
7.4
33.5
9.3
5.7
23.9
6.7
30.1
8.4
5.1
21.4
5.9
26.8
7.5
4.5
18.9
5.3
23.8
6.6
4.0
16.6
4.6
20.9
5.8
3.4
14.5
4.0
18.2
5.1
3.0
12.5
3.5
15.7
4.4
2.5
10.6
3.0
13.4
3.7
2.1
8.9
2.5
11.2
3.1
1.8
7.4
2.1
9.3
2.6
1.4
6.0
1.7
7.5
2.1
1.1
4.7
1.3
5.9
1.7
0.9
3.6
1.0
4.6
1.3
0.6
2.7
0.7
3.3
0.9
56
65
82

Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on 90% Mechanical Efficiency. *Operation below 150 RPM requires an optional
externally-mounted electric motor-driven auxillary lubrication system.
The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own
evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that
stipulated in National Oilwell Standard Terms and Conditions of Sale.

Authorized Distributor:

www.natoil.com / customer.service@natoil.com
10000 Richmond, Houston, Texas 77042
(713)346-7500 (phone) (713)346-7366 (fax)

125T-4 Triplex Plunger Pump


Specifications

43
C PUMP
L

9 7/8
E
21 1/2
3 3/4

3 5/8

3.750
3.749

DIA

7/8 x 7/16 KEYWAY

2 3/8

3 1/4
1/
54

AND DISCHARGE

C CRANK
L

E
9 7/8

FACE OF SUCTION

21 1/2

26

Pump Size
maximum plunger size x stroke length in.(mm):
4 x 4 (101.6 x 101.6)
Rated bhp at 450 rpm (kw): 125 (93)
Rated plunger load pounds(Kg): 8250 (3742.2)
Maximum discharge pressure: psi(kPa)
L model: 1500 (10,342)
M model: 3180 (21,925)
H model: 5000 (34,474)
Crankshaft extension: in.(mm)
Diameter: 3 3/4 (95.25)
Length: 7 1/2 (191)
Keyway (width x depth):
7/8 x 7/16 (22.2 x 11.1)
Maximum recommended sheave
in.(mm): 44 (1118)
Minimum recommended sheave
in.(mm): 24 (610)
For larger sizes: Contact Factory
Pinion shaft extension,
if gear reducer is supplied in.(mm)
For belt or chain drive: Contact Factory
For direct drive: Diameter: 2 7/8 (73)
Length: 6 3/4 (171)
Keyway (width x depth):
3/4 x 3/8 (19 x 9.5)
Accessory gear reduction unit:
2.596:1, 3.109:1, 3.947:1, 6.192:1
Oil Capacity, gallons (L)
Crankcase & Gear - Approximate: 10 (38)
Weight, pump only on
wood shipping skids pounds (Kg):
1747 (792)
with Gear reducer, approximate pounds (Kg):
2322 (1053)

28

9 1/4

36 3/8
A

Pump Model
125T-4L
125T-4M
125T-4H

Flange Connections
Discharge Connection Sizes Suction Connection Sizes
3 (76.2) Sch. 160, V-Bevel
6 (152.4) Sch. 40, V-bevel
3 (76.2) Sch. 160, V-Bevel
4 (101.6) Sch. 40, V-bevel
2 (50.8) Sch. 160, V-Bevel
3 (76.1) Sch. 40, V-bevel

A
53
52 1/8
52 1/8

B
2
4
6 3/8

Dimensions in inches (mm)


C
D
E
F
G
15 3/4
20 1/2
16
32
6
14
19 7/8
15
30
4
12 3/4
17 7/8
15
30
3

H
3
3
2

J
56 7/8
56
56

125T-4 Triplex Plunger Pump


Performance Data
PUMP

125T-4L

125T-4M

125T-4H

PUMP

125T-4L

125T-4M

125T-4H

English Units
Plunger
Plunger
BPD
Dia.
Area
per
In.
Sq. In.
RPM
4.000
12.5664
22.3816
3.750
11.0447
19.6714
3.500
9.6211
17.1359
3.000
7.0686
12.5897
2.750
5.9396
10.5788
2.500
4.9087
8.7428
2.375
4.4301
7.8904
3.000
7.0686
12.5897
2.750
5.9396
10.5788
2.500
4.9087
8.7428
2.250
3.9761
7.0817
2.000
3.1416
5.5954
1.875
2.7612
4.9178
1.750
2.4053
4.2840
1.625
2.0739
3.6938
2.250
3.9761
7.0817
2.000
3.1416
5.5954
1.875
2.7612
4.9178
1.750
2.4053
4.2840
1.625
2.0739
3.6938
1.500
1.7671
3.1474
1.375
1.4849
2.6447
Brake Horsepower Required

GPM
per
RPM
0.6528
0.5737
0.4998
0.3672
0.3085
0.2550
0.2301
0.3672
0.3085
0.2550
0.2065
0.1632
0.1434
0.1249
0.1077
0.2065
0.1632
0.1434
0.1249
0.1077
0.0918
0.0771

Metric Units
Plunger
Plunger
Dia.
Area
mm
cm2
102
81.073
95
71.256
89
62.072
76
45.604
70
38.320
64
31.669
60
28.581
76
45.604
70
38.320
64
31.669
57
25.652
51
20.268
48
17.814
44
15.518
41
13.380
57
25.652
51
20.268
48
17.814
44
15.518
41
13.380
38
11.401
35
9.580
Kilowatts Required

L/Sec.
per
RPM
0.0412
0.0362
0.0315
0.0232
0.0195
0.0161
0.0145
0.0232
0.0195
0.0161
0.0130
0.0103
0.0090
0.0079
0.0068
0.0130
0.0103
0.0090
0.0079
0.0068
0.0058
0.0049

M3/Hr
per
RPM
0.1483
0.1303
0.1135
0.0834
0.0701
0.0579
0.0523
0.0834
0.0701
0.0579
0.0469
0.0371
0.0326
0.0284
0.0245
0.0469
0.0371
0.0326
0.0284
0.0245
0.0208
0.0175

150 RPM
Max.
Press.
PSI
657
747
857
1167
1389
1500
1500
1167
1389
1681
2075
2626
2988
3180
3180
2075
2626
2988
3430
3978
4669
5000

BPD
3358
2951
2571
1889
1587
1312
1184
1889
1587
1312
1063
840
738
643
555
1063
840
738
643
555
473
397

GPM
97.9
86.1
75.0
55.1
46.3
38.2
34.5
55.1
46.3
38.2
31.0
24.5
21.5
18.7
16.2
31.0
24.5
21.5
18.7
16.2
13.8
11.6
42

250 RPM

BPD
5596
4918
4284
3148
2645
2186
1973
3148
2645
2186
1771
1399
1230
1071
924
1771
1399
1230
1071
924
787
662

GPM
163.2
143.4
124.9
91.8
77.1
63.7
57.5
91.8
77.1
63.7
51.6
40.8
35.9
31.2
26.9
51.6
40.8
35.9
31.2
26.9
22.9
19.3

300 RPM

BPD
6715
5902
5141
3777
3174
2623
2368
3777
3174
2623
2125
1679
1476
1286
1109
2125
1679
1476
1286
1109
945
794

70

150 RPM
250 RPM
Max.
Press.
kPa M3/Hr L/Sec. M3/Hr L/Sec.
4527
22.2
6.2
37.1
10.3
5150
19.5
5.4
32.6
9.0
5912
17.0
4.7
28.4
7.9
8047
12.5
3.5
20.8
5.8
9577
10.5
2.9
17.5
4.9
10342
8.7
2.4
14.5
4.0
10342
7.8
2.2
13.1
3.6
8047
12.5
3.5
20.8
5.8
9577
10.5
2.9
17.5
4.9
11588
8.7
2.4
14.5
4.0
14306
7.0
2.0
11.7
3.3
18106
5.6
1.5
9.3
2.6
20601
4.9
1.4
8.1
2.3
21925
4.3
1.2
7.1
2.0
21925
3.7
1.0
6.1
1.7
14306
7.0
2.0
11.7
3.3
18106
5.6
1.5
9.3
2.6
20601
4.9
1.4
8.1
2.3
23649
4.3
1.2
7.1
2.0
27427
3.7
1.0
6.1
1.7
32189
3.1
0.9
5.2
1.4
34474
2.6
0.7
4.4
1.2
31
52

GPM
195.8
172.1
149.9
110.2
92.6
76.5
69.0
110.2
92.6
76.5
62.0
49.0
43.0
37.5
32.3
62.0
49.0
43.0
37.5
32.3
27.5
23.1

350 RPM

BPD
7834
6885
5998
4407
3703
3060
2762
4407
3703
3060
2479
1959
1722
1500
1293
2479
1959
1722
1500
1293
1102
926

GPM
228.5
200.8
174.9
128.5
108.0
89.2
80.5
128.5
108.0
89.2
72.3
57.1
50.2
43.7
37.7
72.3
57.1
50.2
43.7
37.7
32.1
27.0

84

97

300 RPM

350 RPM

M3/Hr
44.5
39.1
34.1
25.0
21.0
17.4
15.7
25.0
21.0
17.4
14.1
11.1
9.8
8.5
7.3
14.1
11.1
9.8
8.5
7.3
6.3
5.3

L/Sec.
12.4
10.9
9.5
6.9
5.8
4.8
4.4
6.9
5.8
4.8
3.9
3.1
2.7
2.4
2.0
3.9
3.1
2.7
2.4
2.0
1.7
1.5
63

M3/Hr
51.9
45.6
39.7
29.2
24.5
20.3
18.3
29.2
24.5
20.3
16.4
13.0
11.4
9.9
8.6
16.4
13.0
11.4
9.9
8.6
7.3
6.1

400 RPM

BPD
8953
7869
6855
5036
4232
3498
3157
5036
4232
3498
2833
2239
1968
1714
1478
2833
2239
1968
1714
1478
1259
1058

GPM
261.1
229.5
199.9
146.9
123.4
102.0
92.1
146.9
123.4
102.0
82.6
65.3
57.4
50.0
43.1
82.6
65.3
57.4
50.0
43.1
36.7
30.9
111

400 RPM

450 RPM

BPD
10072
8853
7712
5666
4761
3935
3551
5666
4761
3935
3187
2518
2214
1928
1663
3187
2518
2214
1928
1663
1417
1191

GPM
293.8
258.2
224.9
165.2
138.8
114.7
103.6
165.2
138.8
114.7
92.9
73.4
64.5
56.2
48.5
92.9
73.4
64.5
56.2
48.5
41.3
34.7
125

450 RPM

L/Sec. M3/Hr L/Sec. M3/Hr L/Sec.


14.4
59.3
16.5
66.7
18.5
12.7
52.1
14.5
58.6
16.3
11.0
45.4
12.6
51.1
14.2
8.1
33.4
9.3
37.5
10.4
6.8
28.0
7.8
31.5
8.8
5.6
23.2
6.4
26.1
7.2
5.1
20.9
5.8
23.5
6.5
8.1
33.4
9.3
37.5
10.4
6.8
28.0
7.8
31.5
8.8
5.6
23.2
6.4
26.1
7.2
4.6
18.8
5.2
21.1
5.9
3.6
14.8
4.1
16.7
4.6
3.2
13.0
3.6
14.7
4.1
2.8
11.4
3.2
12.8
3.5
2.4
9.8
2.7
12.8
3.1
4.6
18.8
5.2
21.1
5.9
3.6
14.8
4.1
16.7
4.6
3.2
13.0
3.6
14.7
4.1
2.8
11.4
3.2
12.8
3.5
2.4
9.8
2.7
11.0
3.1
2.0
8.3
2.3
9.4
2.6
1.7
7.0
1.9
7.9
2.2
73
83
93

Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on 90% Mechanical Efficiency. Not all plunger sizes are shown. Contact
National-Oilwell for additional information.
The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own
evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that
stipulated in National Oilwell Standard Terms and Conditions of Sale.

Authorized Distributor:

www.natoil.com / customer.service@natoil.com
10000 Richmond, Houston, Texas 77042
(713)346-7500 (phone) (713)346-7366 (fax)

130T-4 Triplex Plunger Pump


5/8" x 5/16" KEYWAY
6 1/2

9 3/8

Specifications

2.375 DIA.
2.374

24 7/16

11 7/16

48 7/8

6 1/2

CL PLUNGER #1

11 1/4

C
6 1/2

22 1/2

CL PLUNGER #2

CL PLUNGER #3

8 5/16

7/8" x 7/16" KEYWAY (BOTH ENDS)

7/8" DIA. MOUNTING


HOLES - 4 PLACES

SHAFT EXTENSION
FOR DIRECT DRIVE
3.750
3.749

SUCTION AND DISCHARGE


CONNECTIONS MAY BE
MADE EITHER END.

1 1/2" N.P.T.
MUD TRAP DRAIN

DIA. (BOTH ENDS)

1 1/2" N.P.T. DRAIN


BOTH SIDES

10 7/8

19 5/8

CL DISCHARGE

CL SUCTION

6
2

Pump Size
maximum plunger size x stroke length in.(mm):
3 5/8 x 4 (92.1 x 101.6)
Rated bhp at 450 rpm (kw): 130 (97)
Rated plunger load, pounds(Kg): 8590 (3899)
Maximum discharge pressure: psi(kPa)
L model: 1750 (12,070)
M model: 3111 (21,458)
H model: 5000 (34,474)
Crankshaft extension: in.(mm)
Diameter: 3 3/4 (95.25)
Length long side: 8 1/2 (215.9)
Length short side: 8 5/16 (211.4)
Keyway (width x depth):
7/8 x 7/16 (22.2 x 11.1)
Maximum recommended sheave
in.(mm): 44 (1118)
Minimum recommended sheave
in.(mm): 24 (610)
For larger sizes: Contact Factory
Pinion shaft extension,
if gear reducer is supplied in.(mm)
For belt or chain drive: Contact Factory
For direct drive: Diameter: 2 3/8 (60.33)
Length: 6 1/2 (165.10)
Keyway (width x depth):
5/8 x 5/16 (15.9 x 7.9)
Accessory gear reduction unit:
2.60:1, 3.15:1, 3.42:1, 3.89:1, 4.27:1
Oil Capacity, gallons (L)
Crankcase: 5.5 (20.8)
Gear Reducer: 3 (11.40)
Weight, pump only on
wood shipping skids pounds (Kg):
2360 (1070.5)
Gear reducer, approximate pounds (Kg):
500 (226.8)

2" N.P.T. DRAIN

27 1/8

8 3/4

D
E

Pump Model
130T-4L
130T-4M
130T-4H

Flange Connections
Discharge Connection Sizes Suction Connection Sizes
2 1/2 (63.5) API-2000 RJ
5 (127) ANSI-150 FF
1 1/2 (38.1) API-5000 RJ
3 (76.2) ANSI-150 FF
1 1/2 (38.1) ANSI-2500 RJ
3 (76.2) ANSI-300 FF

A
5 5/8
4 3/4
4 3/4

Dimensions in inches (mm)


B
C
D
E
6 7/8
25 1/2
42 5/8
58 3/8
5 1/4
23 3/4
41 7/8
55 3/8
5 1/4
25 1/2
41 1/2
56 3/8

130T-4 Triplex Plunger Pump


Performance Data
PUMP

130T-4L

130T-4M

130T-4H

PUMP

130T-4L

130T-4M

130T-4H

English Units
Plunger
Plunger
BPD
Dia.
Area
per
In.
Sq. In.
RPM
3.625
10.3206
18.3818
3.500
9.6211
17.1359
3.250
8.2958
14.7754
3.000
7.0686
12.5897
2.750
5.9396
10.5788
2.625
5.4119
9.6390
2.500
4.9087
8.7428
2.375
4.4301
7.8904
2.250
3.9761
7.0817
2.125
3.5466
6.3167
2.000
3.1416
5.5954
1.875
2.7612
4.9178
1.750
2.4053
4.2840
1.625
2.0739
3.6938
1.500
1.7671
3.1474
1.375
1.4849
2.6447
Brake Horsepower Required

GPM
per
RPM
0.5361
0.4998
0.4309
0.3672
0.3085
0.2811
0.2550
0.2301
0.2065
0.1842
0.1632
0.1434
0.1249
0.1077
0.0918
0.0771

Metric Units
Plunger
Plunger
Dia.
Area
mm
cm2
92
66.584
89
62.072
83
53.521
76
45.604
70
38.320
67
34.915
64
31.669
60
28.581
57
25.652
54
22.881
51
20.268
48
17.814
44
15.518
41
13.380
38
11.401
35
9.580
Kilowatts Required

L/Sec.
per
RPM
0.0338
0.0315
0.0272
0.0232
0.0195
0.0177
0.0161
0.0145
0.0130
0.0116
0.0103
0.0090
0.0079
0.0068
0.0058
0.0049

M3/Hr
per
RPM
0.1218
0.1135
0.0979
0.0834
0.0701
0.0638
0.0579
0.0523
0.0469
0.0418
0.0371
0.0326
0.0284
0.0245
0.0208
0.0175

150 RPM
Max.
Press.
PSI
832
893
1035
1215
1446
1587
1750
1939
2160
2422
2734
3111
3571
4142
4861
5000

BPD
2758
2571
2217
1889
1587
1446
1312
1184
1063
948
840
738
643
555
473
397

GPM
80.4
75.0
64.6
55.1
46.3
42.2
38.2
34.5
31.0
27.6
24.5
21.5
18.7
16.2
13.8
11.6
44

250 RPM

BPD
4596
4284
3694
3148
2645
2410
2186
1973
1771
1580
1399
1230
1071
924
787
662

300 RPM

GPM
134.0
124.9
107.7
91.8
77.1
70.3
63.7
57.5
51.6
46.1
40.8
35.9
31.2
26.9
22.9
19.3

BPD
5515
5141
4433
3777
3174
2892
2623
2368
2125
1896
1679
1476
1286
1109
945
794

73

GPM
160.8
149.9
129.3
110.2
92.6
84.3
76.5
69.0
62.0
55.3
49.0
43.0
37.5
32.3
27.5
23.1

350 RPM

BPD
6434
5998
5172
4407
3703
3374
3060
2762
2479
2211
1959
1722
1500
1293
1102
926

87

150 RPM
250 RPM
Max.
Press.
kPa M3/Hr L/Sec. M3/Hr L/Sec.
5739
18.3
5.1
30.4
8.5
6156
17.0
4.7
28.4
7.9
7139
14.7
4.1
24.5
6.8
8379
12.5
3.5
20.8
5.8
9971
10.5
2.9
17.5
4.9
10944
9.6
2.7
16.0
4.4
12065
8.7
2.4
14.5
4.0
13369
7.8
2.2
13.1
3.6
14896
7.0
2.0
11.7
3.3
16700
6.3
1.7
10.5
2.9
18852
5.6
1.5
9.3
2.6
21450
4.9
1.4
8.1
2.3
24623
4.3
1.2
7.1
2.0
28557
3.7
1.0
6.1
1.7
33515
3.1
0.9
5.2
1.4
34474
2.6
0.7
4.4
1.2
33
54

300 RPM

M3/Hr
36.5
34.1
29.4
25.0
21.0
19.2
17.4
15.7
14.1
12.6
11.1
9.8
8.5
7.3
6.3
5.3

L/Sec.
10.1
9.5
8.2
6.9
5.8
5.3
4.8
4.4
3.9
3.5
3.1
2.7
2.4
2.0
1.7
1.5
65

GPM
187.6
174.9
150.8
128.5
108.0
98.4
89.2
80.5
72.3
64.5
57.1
50.2
43.7
37.7
32.1
27.0
101

350 RPM

M3/Hr
42.6
39.7
34.3
29.2
24.5
22.3
20.3
18.3
16.4
14.6
13.0
11.4
9.9
8.6
7.3
6.1

400 RPM

BPD
7353
6855
5911
5036
4232
3856
3498
3157
2833
2527
2239
1968
1714
1478
1259
1058

GPM
214.5
199.9
172.4
146.9
123.4
112.5
102.0
92.1
82.6
73.7
65.3
57.4
50.0
43.1
36.7
30.9
116

400 RPM

450 RPM

BPD
8272
7712
6649
5666
4761
4338
3935
3551
3187
2843
2518
2214
1928
1663
1417
1191

GPM
241.3
224.9
193.9
165.2
138.8
126.5
114.7
103.6
92.9
82.9
73.4
64.5
56.2
48.5
41.3
34.7
130

450 RPM

L/Sec. M3/Hr L/Sec. M3/Hr L/Sec.


11.8
48.7
13.5
54.8
15.2
11.0
45.4
12.6
51.1
14.2
9.5
39.1
10.9
44.0
12.2
8.1
33.4
9.3
37.5
10.4
6.8
28.0
7.8
31.5
8.8
6.2
25.5
7.1
28.7
8.0
5.6
23.2
6.4
26.1
7.2
5.1
20.9
5.8
23.5
6.5
4.6
18.8
5.2
21.1
5.9
4.1
16.7
4.6
18.8
5.2
3.6
14.8
4.1
16.7
4.6
3.2
13.0
3.6
14.7
4.1
2.8
11.4
3.2
12.8
3.5
2.4
9.8
2.7
11.0
3.1
2.0
8.3
2.3
9.4
2.6
1.7
7.0
1.9
7.9
2.2
75
86
97

Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on 90% Mechanical Efficiency. Not all plunger sizes are shown. Contact National-Oilwell for
additional information. For operations below 200 RPM, auxiliary lubrication system required.
The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own
evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that
stipulated in National Oilwell Standard Terms and Conditions of Sale.

Authorized Distributor:

www.natoil.com / customer.service@natoil.com
10000 Richmond, Houston, Texas 77042
(713)346-7500 (phone) (713)346-7366 (fax)

133T-4 Triplex Plunger Pump


Specifications

INTERNAL LUBE PUMP

.75
TYP
4 PLACES
PRESSURE GAUGE

19.37

8.00
18.25
16.00

C/2
13.23

ROTATION DIRECTION
9.84

3.750
3.749

.875 x .500 KEYWAY


7.750 LONG
DISCHARGE
CONNECTION

F
A
20.31

B
10.00

1.00
SUCTION
CONNECTION

5.25

8.81

24.25

Pump Model
133T-4L
133T-4M
133T-4H

Flange Connections
Discharge Connection Sizes Suction Connection Sizes
3 (76.2)-600# ANSI FF
6 (152.4)-150# ANSI FF
2 (50.8)-1500# ANSI FF
4 (101.6)-300# ANSI FF
2 (50.8)-2500# ANSI RJ
3 (76.2)-2500# ANSI RJ

A
4 5/8
5 1/16
5 1/8

Pump Size:
maximum plunger size x stroke length, in.(mm):
3.375 x 4.500 (85.7 x 114.3)
Rated BHP (kW) at 400 RPM: 133 (99)
Rated plunger load, pounds (kg): 8800 (3992)
Maximum discharge pressure: psi (kPa)
L model: 1440 (9929)
M model: 3600 (24821)
H model: 6000 (41369)
Crankshaft extension:
Diameter, in.(mm): 3.750 (95.25)
Length, in.(mm): 9.84 (249.9)
Keyway width x depth, in.(mm):
7/8 x 1/2 (22.225 x 12.7)
Maximum recommended sheave diameter,
in. (mm): 53 (1346.2)
For larger sizes: Contact Factory
Pinion shaft extension,
if gear reducer is supplied, in. (mm)
For belt or chain drive: N/A
For direct drive: Diameter: 2.000 (50.8)
Length: 4.25 (108.0)
Keyway width x depth:
1/2 x 1/4 (12.70 x 6.35)
Accessory gear reduction unit:
3.00:1, 3.12:1, 3.23:1, 3.36:1, 3.49:1,
3.62:1, 3.78:1, 3.94:1, 4.11:1, 4.29:1,
4.48:1, 4.69:1, 4.93:1, 5.17:1
Oil Capacity, gallons (L)
Crankcase: 6 (22.71)
Gear Reducer - varies with ratio:
1.25 to 1.50 (4.73 to 5.68)
Weight, pump only on
wood shipping skids, pounds (kg)
L model: 1650 (748)
M model: 1650 (748)
H model: 1650 (748)
Standard Materials For Fluid End Bodies
L model
Cast Nickel-Aluminum-Bronze
Cast Duplex Stainless Steel
Forged/Plate Carbon Steel
M model
Cast Nickel-Aluminum-Bronze
Cast Duplex Stainless Steel
Forged/Plate Carbon Steel
H model
Forged Carbon Steel
Duplex Stainless Steel

Dimensions (Inches)
B
C
D
E
7 7/8
2
33 3/4
48 5/8
6 3/16
2
33 3/8
47 3/4
6 1/8
30 1/8
36 3/4
52 1/2

F
9 5/8
9
12 1/8

133T-4 Triplex Plunger Pump


Performance Data
PUMP

133T-4L
(T140-4)

133T-4M
(T140-3)

133T-4H
(T140-2)

PUMP

133T-4L
(T140-4)

133T-4M
(T140-3)

133T-4H
(T140-2)

English Units
Plunger
Plunger
BPD
Dia.
Area
per
In.
Sq. In.
RPM
3.375
8.9462
17.9255
3.250
8.2958
16.6223
3.125
7.6699
15.3682
3.000
7.0686
14.1634
2.875
6.4918
13.0077
2.750
5.9396
11.9012
2.625
5.4119
10.8438
2.500
4.9087
9.8357
2.375
4.4301
8.8767
2.250
3.9761
7.9669
2.125
3.5466
7.1063
2.000
3.1416
6.2948
1.875
2.7612
5.5326
1.750
2.4053
4.8195
1.625
2.0739
4.1556
1.500
1.7671
3.5408
1.375
1.4849
2.9753
1.250
1.2272
2.4589
Brake Horsepower Required

GPM
per
RPM
0.5228
0.4848
0.4482
0.4131
0.3794
0.3471
0.3163
0.2869
0.2589
0.2324
0.2073
0.1836
0.1614
0.1406
0.1212
0.1033
0.0868
0.0717

Metric Units
Plunger
Plunger
Dia.
Area
mm
cm2
86
57.717
83
53.521
79
49.483
76
45.604
73
41.883
70
38.320
67
34.915
64
31.669
60
28.581
57
25.652
54
22.881
51
20.268
48
17.814
44
15.518
41
13.380
38
11.401
35
9.580
32
7.917
Kilowatts Required

L/Sec.
per
RPM
0.0330
0.0306
0.0283
0.0261
0.0239
0.0219
0.0200
0.0181
0.0163
0.0147
0.0131
0.0116
0.0102
0.0089
0.0076
0.0065
0.0055
0.0045

M3/Hr
per
RPM
0.1187
0.1101
0.1018
0.0938
0.0862
0.0788
0.0718
0.0651
0.0588
0.0528
0.0471
0.0417
0.0366
0.0319
0.0275
0.0235
0.0197
0.0163

100 RPM
Max.
Press.
PSI
984
1061
1147
1245
1356
1440
1440
1793
1986
2213
2481
2801
3187
3600
4243
4980
5926
6000

BPD
1793
1663
1537
1417
1301
1191
1085
984
888
797
711
630
554
482
416
355
298
246

GPM
52.3
48.5
44.8
41.3
37.9
34.7
31.6
28.7
25.9
23.2
20.7
18.4
16.1
14.1
12.1
10.3
8.7
7.2
34

150 RPM

BPD
2689
2494
2306
2125
1952
1786
1627
1476
1332
1196
1066
945
830
723
624
532
447
369

250 RPM

GPM
78.4
72.7
67.2
62.0
56.9
52.1
47.4
43.0
38.8
34.9
31.1
27.5
24.2
21.1
18.2
15.5
13.0
10.8

BPD
4482
4156
3843
3541
3252
2976
2711
2459
2220
1992
1777
1574
1384
1205
1039
886
744
615

51

300 RPM

GPM
130.7
121.2
112.1
103.3
94.8
86.8
79.1
71.7
64.7
58.1
51.8
45.9
40.3
35.1
30.3
25.8
21.7
17.9

BPD
5378
4987
4611
4250
3903
3571
3254
2951
2664
2391
2132
1889
1660
1446
1247
1063
893
738

84

100 RPM
150 RPM
Max.
Press.
kPa M3/Hr L/Sec. M3/Hr L/Sec.
6782
11.9
3.3
17.8
4.9
7314
11.0
3.1
16.5
4.6
7911
10.2
2.8
15.3
4.2
8584
9.4
2.6
14.1
3.9
9346
8.6
2.4
12.9
3.6
9929
7.9
2.2
11.8
3.3
9929
7.2
2.0
10.8
3.0
12360
6.5
1.8
9.8
2.7
13696
5.9
1.6
8.8
2.5
15260
5.3
1.5
7.9
2.2
17108
4.7
1.3
7.1
2.0
19313
4.2
1.2
6.3
1.7
21974
3.7
1.0
5.5
1.5
24821
3.2
0.9
4.8
1.3
29256
2.8
0.8
4.1
1.1
34335
2.3
0.7
3.5
1.0
40861
2.0
0.5
3.0
0.8
41369
1.6
0.5
2.4
0.7
25
38

250 RPM

M3/Hr
29.7
27.5
25.4
23.5
21.5
19.7
18.0
16.3
14.7
13.2
11.8
10.4
9.2
8.0
6.9
5.9
4.9
4.1

L/Sec.
8.2
7.6
7.1
6.5
6.0
5.5
5.0
4.5
4.1
3.7
3.3
2.9
2.5
2.2
1.9
1.6
1.4
1.1
63

GPM
156.8
145.4
134.5
123.9
113.8
104.1
94.9
86.1
77.7
69.7
62.2
55.1
48.4
42.2
36.4
31.0
26.0
21.5
100

300 RPM

M3/Hr
35.6
33.0
30.5
28.1
25.8
23.6
21.5
19.5
17.6
15.8
14.1
12.5
11.0
9.6
8.3
7.0
5.9
4.9

350 RPM

BPD
6274
5818
5379
4958
4553
4166
3796
3443
3107
2789
2488
2204
1937
1687
1455
1240
1042
861

GPM
183.0
169.7
156.9
144.6
132.8
121.5
110.7
100.4
90.6
81.3
72.5
64.3
56.5
49.2
42.4
36.1
30.4
25.1
117

350 RPM

400 RPM

BPD
7171
6649
6148
5666
5204
4761
4338
3935
3551
3187
2843
2518
2214
1928
1663
1417
1191
984

GPM
209.1
193.9
179.3
165.2
151.8
138.8
126.5
114.7
103.6
92.9
82.9
73.4
64.5
56.2
48.5
41.3
34.7
28.7
133

400 RPM

L/Sec. M3/Hr L/Sec. M3/Hr L/Sec.


9.9
41.6
11.5
47.5
13.2
9.2
38.5
10.7
44.0
12.2
8.5
35.6
9.9
40.7
11.3
7.8
32.8
9.1
37.5
10.4
7.2
30.2
8.4
34.5
9.6
6.6
27.6
7.7
31.5
8.8
6.0
25.1
7.0
28.7
8.0
5.4
22.8
6.3
26.1
7.2
4.9
20.6
5.7
23.5
6.5
4.4
18.5
5.1
21.1
5.9
3.9
16.5
4.6
18.8
5.2
3.5
14.6
4.1
16.7
4.6
3.1
12.8
3.6
14.7
4.1
2.7
11.2
3.1
12.8
3.5
2.3
9.6
2.7
11.0
3.1
2.0
8.2
2.3
9.4
2.6
1.6
6.9
1.9
7.9
2.2
1.4
5.7
1.6
6.5
1.8
75
87
99

Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on 90% Mechanical Efficiency.
The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own
evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that
stipulated in National Oilwell Standard Terms and Conditions of Sale.

Authorized Distributor:

www.natoil.com / customer.service@natoil.com
10000 Richmond, Houston, Texas 77042
(713)346-7500 (phone) (713)346-7366 (fax)

163Q-4 Quintuplex Plunger Pump


Specifications

20.79
14.00
TYP

C
28.00
TYP

C/2
19.22

.75
TYP
4 PLACES

6.27

.750 x .375 KEYWAY


5.125 LONG

3.000
2.999

ROTATION
DIRECTION

DISCHARGE
CONNECTION

F
A

1.00
20.42

B
10.00
.75

SUCTION
CONNECTION
5.25

24.25

9.89

Pump Model
163Q-4L
163Q-4M
163Q-4H

Flange Connections
Discharge Connection Sizes Suction Connection Sizes
3 (76.2)-600# ANSI FF
6 (152.4)-150# ANSI FF
2 (50.8)-1500# ANSI FF
4 (101.6)-300# ANSI FF
2 (50.8)-11 1/2 NPT
3 (76.2)-8 NPT

A
4 5/8
5 1/16
5 1/16

Pump Size:
maximum plunger size x stroke length, in.(mm):
3.375 x 4.500 (85.725 x 114.3)
Rated BHP (kW) at 390 RPM: 163 (121)
Rated plunger load, pounds (kg): 6600 (2994)
Maximum discharge pressure: psi (kPa)
L model: 1220 (8408)
M model: 2744 (18919)
H model: 5378 (37081)
Crankshaft extension:
Diameter, in.(mm): 3.000 (76.2)
Length, in.(mm): 6.27 (159.3)
Keyway width x depth, in.(mm):
3/4 x 3/8 (19.05 x 9.525)
Maximum recommended sheave diameter,
in.(mm): 53 (1346.2)
For larger sizes: Contact Customer Service
Pinion shaft extension,
if gear reducer is supplied, in.(mm)
For belt or chain drive: N/A
For direct drive: Diameter: 2.500 (63.5)
Length: 5.000 (127.0)
Keyway width x depth:
5/8 x 5/16 (15.88 x7.94)
Accessory gear reduction unit:
2.06:1, 2.26:1, 3.60:1, 4.25:1, 4.65:1,
4.88:1, 5.13:1, 5.40:1, 5.69:1
Oil Capacity, gallons (L)
Crankcase: 7 (26.5)
Gear Reducer-varies with ratio:
2.00 to 2.25 (7.57 to 8.52)
Weight, pump only on
wood shipping skids, pounds (kg): 2913 (1322)
Weight varies with pump model
Standard Materials for Fluid Ends:
L model
Cast Nickel-Aluminum-Bronze
Cast Duplex Stainless Steel
Plate Carbon Steel
Cast Ductile Iron
M model
Cast Nickel-Aluminum-Bronze
Cast Duplex Stainless Steel
Plate Carbon Steel
Forged Nickel-Aluminum-Bronze
H model
Forged 15-5 Stainless Steel
Forged/Plate Carbon Steel

Dimensions (Inches)
B
C
D
E
7 7/8
33
33 3/8
49 7/16
5 7/8
33
33
38 3/4
6 3/16 31 1/2
33
39 3/4

F
9 5/8
9 1/2
10 3/4

G
3 3/8
7/8
-1 5/8

163Q-4 Quintuplex Plunger Pump


Performance Data
PUMP

163Q-4L
(HP165AL)

163Q-4M
(HP165AM)

163Q-4H
(HP165MS)

PUMP

163Q-4L
(HP165AL)

163Q-4M
(HP165AM)

163Q-4H
(HP165MS)

English Units
Plunger
Plunger
BPD
Dia.
Area
per
In.
Sq. In.
RPM
3.375
8.9462
29.8759
3.250
8.2958
27.7038
3.125
7.6699
25.6137
3.000
7.0686
23.6056
2.875
6.4918
21.6795
2.750
5.9396
19.8353
2.625
5.4119
18.0731
2.500
4.9087
16.3928
2.375
4.4301
14.7945
2.250
3.9761
13.2782
2.125
3.5466
11.8438
2.000
3.1416
10.4914
1.875
2.7612
9.2209
1.750
2.4053
8.0325
1.625
2.0739
6.9260
1.500
1.7671
5.9014
1.375
1.4849
4.9588
1.250
1.2272
4.0982
Brake Horsepower Required

GPM
per
RPM
0.8714
0.8080
0.7471
0.6885
0.6323
0.5785
0.5271
0.4781
0.4315
0.3873
0.3454
0.3060
0.2689
0.2343
0.2020
0.1721
0.1446
0.1195

Metric Units
Plunger
Plunger
Dia.
Area
mm
cm2
86
57.717
83
53.521
79
49.483
76
45.604
73
41.883
70
38.320
67
34.915
64
31.669
60
28.581
57
25.652
54
22.881
51
20.268
48
17.814
44
15.518
41
13.380
38
11.401
35
9.580
32
7.917
Kilowatts Required

L/Sec.
per
RPM
0.0550
0.0510
0.0471
0.0434
0.0399
0.0365
0.0333
0.0302
0.0272
0.0244
0.0218
0.0193
0.0170
0.0148
0.0127
0.0109
0.0091
0.0075

M3/Hr
per
RPM
0.1979
0.1835
0.1697
0.1564
0.1436
0.1314
0.1197
0.1086
0.0980
0.0880
0.0785
0.0695
0.0611
0.0532
0.0459
0.0391
0.0328
0.0271

50 RPM
Max.
Press.
PSI
738
796
861
934
1017
1111
1220
1345
1490
1660
1861
2101
2390
2744
3182
3735
4445
5378

BPD
1494
1386
1281
1181
1084
992
904
820
740
664
593
525
462
402
347
296
248
205

GPM
43.6
40.4
37.4
34.4
31.6
28.9
26.4
23.9
21.6
19.4
17.3
15.3
13.4
11.7
10.1
8.6
7.2
6.0
21

150 RPM

BPD
4482
4156
3843
3541
3252
2976
2711
2459
2220
1992
1777
1574
1384
1205
1039
886
744
615

200 RPM

GPM
130.7
121.2
112.1
103.3
94.8
86.8
79.1
71.7
64.7
58.1
51.8
45.9
40.3
35.1
30.3
25.8
21.7
17.9

BPD
5976
5541
5123
4722
4336
3968
3615
3279
2959
2656
2369
2099
1845
1607
1386
1181
992
820

63

GPM
174.3
161.6
149.4
137.7
126.5
115.7
105.4
95.6
86.3
77.5
69.1
61.2
53.8
46.9
40.4
34.4
28.9
23.9

250 RPM

BPD
7469
6926
6404
5902
5420
4959
4519
4099
3699
3320
2961
2623
2306
2009
1732
1476
1240
1025

84

50 RPM
150 RPM
Max.
Press.
kPa M3/Hr L/Sec. M3/Hr L/Sec.
5087
9.9
2.7
29.7
8.2
5485
9.2
2.5
27.5
7.6
5933
8.5
2.4
25.4
7.1
6438
7.8
2.2
23.5
6.5
7010
7.2
2.0
21.5
6.0
7661
6.6
1.8
19.7
5.5
8408
6.0
1.7
18.0
5.0
9270
5.4
1.5
16.3
4.5
10272
4.9
1.4
14.7
4.1
11445
4.4
1.2
13.2
3.7
12831
3.9
1.1
11.8
3.3
14485
3.5
1.0
10.4
2.9
16481
3.1
0.8
9.2
2.5
18919
2.7
0.7
8.0
2.2
21942
2.3
0.6
6.9
1.9
25751
2.0
0.5
5.9
1.6
30646
1.6
0.5
4.9
1.4
37081
1.4
0.4
4.1
1.1
16
47

200 RPM

M3/Hr
39.6
36.7
33.9
31.3
28.7
26.3
23.9
21.7
19.6
17.6
15.7
13.9
12.2
10.6
9.2
7.8
6.6
5.4

L/Sec.
11.0
10.2
9.4
8.7
8.0
7.3
6.7
6.0
5.4
4.9
4.4
3.9
3.4
3.0
2.5
2.2
1.8
1.5
63

GPM
217.8
202.0
186.8
172.1
158.1
144.6
131.8
119.5
107.9
96.8
86.4
76.5
67.2
58.6
50.5
43.0
36.2
29.9
104

250 RPM

M3/Hr
49.5
45.9
42.4
39.1
35.9
32.8
29.9
27.1
24.5
22.0
19.6
17.4
15.3
13.3
11.5
9.8
8.2
6.8

300 RPM

BPD
8963
8312
7685
7082
6504
5951
5422
4918
4439
3984
3554
3148
2767
2410
2078
1771
1488
1230

GPM
261.4
242.4
224.1
206.5
189.7
173.6
158.1
143.4
129.5
116.2
103.6
91.8
80.7
70.3
60.6
51.6
43.4
35.9
125

300 RPM

390 RPM

BPD
11652
10805
9990
9207
8455
7736
7049
6394
5770
5179
4620
4092
3597
3133
2702
2302
1934
1599

GPM
339.8
315.1
291.4
268.5
246.6
225.6
205.6
186.5
168.3
151.0
134.7
119.3
104.9
91.4
78.8
67.1
56.4
46.6
163

390 RPM

L/Sec. M3/Hr L/Sec. M3/Hr L/Sec.


13.7
59.4
16.5
77.2
21.4
12.7
55.1
15.3
71.6
19.9
11.8
50.9
14.1
66.2
18.4
10.9
46.9
13.0
61.0
16.9
10.0
43.1
12.0
56.0
15.6
9.1
39.4
10.9
51.2
14.2
8.3
35.9
10.0
46.7
13.0
7.5
32.6
9.0
42.3
11.8
6.8
29.4
8.2
38.2
10.6
6.1
26.4
7.3
34.3
9.5
5.4
23.5
6.5
30.6
8.5
4.8
20.8
5.8
27.1
7.5
4.2
18.3
5.1
23.8
6.6
3.7
16.0
4.4
20.7
5.8
3.2
13.8
3.8
17.9
5.0
2.7
11.7
3.3
15.2
4.2
2.3
9.9
2.7
12.8
3.6
1.9
8.1
2.3
10.6
2.9
78
93
121

Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on 90% Mechanical Efficiency. *Operation below 150 RPM requires an optional externallymounted electric motor-driven auxillary lubrication system.
The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own
evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that
stipulated in National Oilwell Standard Terms and Conditions of Sale.

Authorized Distributor:

www.natoil.com / customer.service@natoil.com
10000 Richmond, Houston, Texas 77042
(713)346-7500 (phone) (713)346-7366 (fax)

165T-5 Triplex Plunger Pump


15 5/8
4.125
4.123

3.000
2.999

DIA

Specifications

DIA

8 1/8

9 7/16

6 3/16

3/4" x 3/8" KEYWAY

SUCTION AND DISCHARGE


CONNECTIONS MAY BE
MADE AT EITHER END

13 1/8

7 1/2

"C"

51 7/8

7 1/2

26 1/4

26 15/16

1" x 1/2" KEYWAY

5 7/8

1 1/8" DIA HOLES


4 PLACES AS SHOWN
1" x 1/2" KEYWAY
4.125
4.123

SHAFT EXTENSION
FOR DIRECT DRIVE

DIA

14 1/2

"D"
36 1/2

+
"B"

10

12 1/4

2 1/4
CENTERLINE
SUCTION

2 1/4

"F"

29

CENTERLINE
DISCHARGE

"A"

1 1/2 " STD PIPE TAP


CRADLE DRAIN, BOTH SIDES

Pump Size
(maximum plunger size x stroke length in.(mm)
4 x 5 (102 x 127)
Rated bhp at 400 rpm (kw)
165 (123)
Rated plunger load, pounds (Kg)
9800 (4445.2)
Maximum discharge pressure: psi (kPa)
L model: 1650 (11,376)
M model: 3120 (21,512)
H model: 5000 (34,474)
Crankshaft extension: in.(mm)
Diameter: 4.125 (104.8)
Length long side: 8 1/8 (206.4)
Length short side: 5 7/8 (149.2)
Keyway (width x depth): 1 x 1/2 (25.4 x 12.7)
Maximum recommended sheave in.(mm):
50 (1270)
Minimum recommended sheave in.(mm):
36 (914)
For larger sizes: Contact Factory
Pinion shaft extension, in.(mm):
if gear reducer is supplied
For belt or chain drive: Contact Factory
For direct drive: Diameter: 3.0 (76.2)
Length: 6 3/16 (157.2)
Keyway (width x depth):
3/4 x 3/8 (19.05 x 9.53)
Accessory gear reduction unit:
2.8:1, 3.22:1, 3.46:1, 4.00:1,
4.38:1, 4.78:1, 4.96:1, 5.74:1
Oil Capacity, gallons (L)
Crankcase: 8 (30)
Gear Reducer-varies with ratio:
2.25 to 3.5 (8.52 to 13.25)
Weight, pump only on wood shipping skids
pounds (Kg): 4000 (1814)
Gear reducer, approximate pounds (Kg):
800 (363)

1 1/2 " STD PIPE TAP


MUD TRAP DRAIN
3 3/4

7 3/4

2" STD PIPE TAP


CRADLE DRAIN

19 3/4
40 3/4
"E"

1" STD PIPE TAP


POWER END OIL DRAIN

Pump Model
165-5L
165-5M
165-5H

Flange Connections
Discharge Connection Sizes Suction Connection Sizes
3 (76.2) API-2000 RJ
6 (152.4) ANSI-150 FF
2 (50.8) API-5000 RJ
4 (101.6) ANSI-150 FF
2 (50.8) ANSI-2500 RJ
3 (76.2) API-2000 RJ

A
5 11/16
4 3/4
4 3/4

Dimensions (Inches)
B
C
D
E
7 5/8
27 3/4
48 3/4
65 3/4
6 1/2
26 1/2
48 3/8
64 7/8
6 1/2
26 1/2
48 3/8
64 1/4

F
23
25 5/16
25 5/16

165T-5 Triplex Plunger Pump


Performance Data
PUMP

165T-5L

165T-5M

165T-5H

PUMP

165T-5L

165T-5M

165T-5H

English Units
Plunger
Plunger
BPD
Dia.
Area
per
In.
Sq. In.
RPM
4.000
12.5664
27.9770
3.750
11.0447
24.5892
3.500
9.6211
21.4199
3.250
8.2958
18.4692
3.000
7.0686
15.7371
2.750
5.9396
13.2235
2.750
5.9396
13.2235
2.500
4.9087
10.9285
2.375
4.4301
9.8630
2.250
3.9761
8.8521
2.125
3.5466
7.8959
2.000
3.1416
6.9943
2.000
3.1416
6.9943
1.875
2.7612
6.1473
1.750
2.4053
5.3550
1.625
2.0739
4.6173
1.500
1.7671
3.9343
Brake Horsepower Required

GPM
per
RPM
0.8160
0.7172
0.6247
0.5387
0.4590
0.3857
0.3857
0.3187
0.2877
0.2582
0.2303
0.2040
0.2040
0.1793
0.1562
0.1347
0.1147

Metric Units
Plunger
Plunger
Dia.
Area
mm
cm2
102
81.073
95
71.256
89
62.072
83
53.521
76
45.604
70
38.320
70
38.320
64
31.669
60
28.581
57
25.652
54
22.881
51
20.268
51
20.268
48
17.814
44
15.518
41
13.380
38
11.401
Kilowatts Required

L/Sec.
per
RPM
0.0515
0.0452
0.0394
0.0340
0.0290
0.0243
0.0243
0.0201
0.0181
0.0163
0.0145
0.0129
0.0129
0.0113
0.0099
0.0085
0.0072

M3/Hr
per
RPM
0.1853
0.1629
0.1419
0.1223
0.1042
0.0876
0.0876
0.0724
0.0653
0.0586
0.0523
0.0463
0.0463
0.0407
0.0355
0.0306
0.0261

100 RPM
Max.
Press.
PSI
780
887
1019
1181
1386
1650
1650
1996
2212
2465
2763
3120
3120
3549
4074
4725
5000

BPD
2798
2459
2142
1847
1574
1323
1323
1093
987
886
790
700
700
615
536
462
394

GPM
81.6
71.7
62.5
53.9
45.9
38.6
38.6
31.9
28.8
25.8
23.0
20.4
20.4
17.9
15.6
13.5
11.5
42

200 RPM

BPD
5596
4918
4284
3694
3148
2645
2645
2186
1973
1771
1580
1399
1399
1230
1071
924
787

250 RPM

GPM
163.2
143.4
124.9
107.7
91.8
77.1
77.1
63.7
57.5
51.6
46.1
40.8
40.8
35.9
31.2
26.9
22.9

BPD
6995
6148
5355
4618
3935
3306
3306
2733
2466
2214
1974
1749
1749
1537
1339
1155
984

83

GPM
204.0
179.3
156.2
134.7
114.7
96.4
96.4
79.7
71.9
64.5
57.6
51.0
51.0
44.8
39.0
33.7
28.7

300 RPM

BPD
8394
7377
6426
5541
4722
3968
3968
3279
2959
2656
2369
2099
2099
1845
1607
1386
1181

104

100 RPM
200 RPM
Max.
Press.
kPa M3/Hr L/Sec. M3/Hr L/Sec.
5377
18.5
5.1
37.1
10.3
6118
16.3
4.5
32.6
9.0
7023
14.2
3.9
28.4
7.9
8145
12.2
3.4
24.5
6.8
9559
10.4
2.9
20.8
5.8
11376
8.8
2.4
17.5
4.9
11376
8.8
2.4
17.5
4.9
13765
7.2
2.0
14.5
4.0
15252
6.5
1.8
13.1
3.6
16994
5.9
1.6
11.7
3.3
19052
5.2
1.5
10.5
2.9
21512
4.6
1.3
9.3
2.6
21512
4.6
1.3
9.3
2.6
24471
4.1
1.1
8.1
2.3
28092
3.5
1.0
7.1
2.0
32580
3.1
0.8
6.1
1.7
34474
2.6
0.7
5.2
1.4
31
62

250 RPM

M3/Hr
46.3
40.7
35.5
30.6
26.1
21.9
21.9
18.1
16.3
14.7
13.1
11.6
11.6
10.2
8.9
7.6
6.5

L/Sec.
12.9
11.3
9.9
8.5
7.2
6.1
6.1
5.0
4.5
4.1
3.6
3.2
3.2
2.8
2.5
2.1
1.8
78

GPM
244.8
215.2
187.4
161.6
137.7
115.7
115.7
95.6
86.3
77.5
69.1
61.2
61.2
53.8
46.9
40.4
34.4
124

300 RPM

M3/Hr
55.6
48.9
42.6
36.7
31.3
26.3
26.3
21.7
19.6
17.6
15.7
13.9
13.9
12.2
10.6
9.2
7.8

350 RPM

BPD
9792
8607
7497
6465
5508
4629
4629
3825
3453
3099
2764
2448
2448
2152
1875
1617
1377

GPM
285.6
251.0
218.7
188.5
160.6
135.0
135.0
111.6
100.7
90.4
80.6
71.4
71.4
62.8
54.7
47.1
40.2

400 RPM

144

BPD
GPM
11191* 326*
9836
286.9
8568
249.9
7388
215.5
6295
183.6
5290
154.3
5290
154.3
4372
127.5
3946
115.1
3541
103.3
3159
92.1
2798
81.6
2798
81.6
2459
71.7
2142
62.5
1847
53.9
1574
45.9
165

350 RPM

400 RPM

L/Sec. M3/Hr L/Sec. M3/Hr L/Sec.


15.4
64.9
18.0
74.1*
20.6*
13.6
57.0
15.8
65.1
18.1
11.8
49.7
13.8
56.8
15.8
10.2
42.8
11.9
48.9
13.6
8.7
36.5
10.1
41.7
11.6
7.3
30.7
8.5
35.0
9.7
7.3
30.7
8.5
35.0
9.7
6.0
25.3
7.0
29.0
8.0
5.4
22.9
6.4
26.1
7.3
4.9
20.5
5.7
23.5
6.5
4.4
18.3
5.1
20.9
5.8
3.9
16.2
4.5
18.5
5.1
3.9
16.2
4.5
18.5
5.1
3.4
14.3
4.0
16.3
4.5
3.0
12.4
3.4
14.2
3.9
2.5
10.7
3.0
12.2
3.4
2.2
9.1
2.5
10.4
2.9
92
108
123

Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on 90% Mechanical Efficiency. For Operations below 200 RPM, an auxiliary lubrication
system is required. Not all plunger sizes are shown. Contact National-Oilwell for additional information. *Spherical Valves must be installed when the pump is fitted with 4.0 (102mm) plungers
The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own
evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that
stipulated in National Oilwell Standard Terms and Conditions of Sale.

Authorized Distributor:

www.natoil.com / customer.service@natoil.com
10000 Richmond, Houston, Texas 77042
(713)346-7500 (phone) (713)346-7366 (fax)

184T-7 Triplex Plunger Pump


INTERNAL LUBE PUMP

Specifications
PRESSURE GAUGE

22.01
13.01
TYP

D
SUCTION

26.00
TYP

C
DISCHARGE

30.24

1.13
TYP 4 PLACES

1.250 x .625 KEY WAY


10.125 LONG

4.500
4.499

DISCHARGE
CONNECTION

ROTATION
DIRECTION

G
1.50

1.50

26.17

13.75

1.25

SUCTION
CONNECTION

6.50

11.74

Pump Size:
maximum plunger size x stroke length, in.(mm):
5.750 x 7.125 (146.05 x 180.975)
Rated BHP (kW) at 265 RPM: 184 (137)
Rated plunger load, pounds (kg): 11580 (5253)
Maximum discharge pressure: psi (kPa)
XL model: 728 (5020)
L model: 1204 (8299)
M model: 2912 (20081)
H model: 6000 (41369)
Crankshaft extension:
Diameter, in.(mm): 4.500 (114.3)
Length, in.(mm): 12.250 (311.15)
Keyway width x depth, in.(mm):
1.25 x 5/8 (31.75 x 15.75)
Maximum recommended sheave diameter,
in.(mm): 63 (1600.2)
For larger sizes: Contact Factory
Oil Capacity, gallons (L)
Crankcase: 17 (64.35)
Weight, pump only on
wood shipping skids, pounds (kg)
XL model: 4900 (2223)
L model: 4600 (2087)
M model: 4300 (1950)
H model: 3800 (1724)
Standard Materials for Fluid Ends:
XL model
Cast Duplex Stainless Steel
Cast Carbon Steel
L model
Cast Nickel-Aluminum-Bronze
Forged/Plate Carbon Steel
M model
Cast Nickel-Aluminum-Bronze
Cast Duplex Stainless Steel
Forged/Plate Carbon Steel
H model
Forged 15-5 Stainless Steel

34.50

Pump Model
184T-7XL
184T-7L
184T-7M
184T-7H

Flange Connections
Discharge Connection Sizes Suction Connection Sizes
4 (101.6)-600# ANSI FF
10 (254.0)-150# ANSI FF
4 (101.6)-900# ANSI FF
6 (152.4)-150# ANSI FF
2.5 (63.5)-1500# ANSI FF
4 (101.6)-300# ANSI FF
2 (50.8)-2500# ANSI RTJ
4 (101.6)-300# ANSI RF

A
10
8 1/4
6 7/8
3 7/16

B
14 3/8
14 3/8
8 3/4
12 7/16

Dimensions (Inches)
C
D
E
F
34
36
48 3/8
72
33
33
46 3/4
71
34
36
48 3/8
71
31
33
53 5/16 68 3/8

G
16 5/8
13 1/4
16 5/8
11 1/2

H
7 1/4
1
-1 1/2
2 1/4

184T-7 Triplex Plunger Pump


Performance Data
PUMP

184T-7XL
(HP250XL)

184T-7L
(HP250BL)

184T-7M
(HP250BM)

184T-7H
(HP250BH)

PUMP

184T-7XL
(HP250XL)

184T-7L
(HP250BL)

184T-7M
(HP250BM)

184T-7H
(HP250BH)

English Units
Plunger
Plunger
BPD
Dia.
Area
per
In.
Sq. In.
RPM
5.750
25.9672
82.3820
5.500
23.7583
75.3741
5.375
22.6906
71.9869
5.250
21.6475
68.6776
5.000
19.6349
62.2926
4.750
17.7205
56.2191
4.500
15.9043
50.4570
4.250
14.1862
45.0064
4.000
12.5664
39.8673
3.750
11.0447
35.0396
3.500
9.6211
30.5234
3.250
8.2958
26.3186
3.125
7.6699
24.3331
3.000
7.0686
22.4253
2.875
6.4918
20.5955
2.750
5.9396
18.8435
2.625
5.4119
17.1694
2.500
4.9087
15.5732
2.375
4.4301
14.0548
2.250
3.9761
12.6143
2.125
3.5466
11.2516
2.000
3.1416
9.9668
1.875
2.7612
8.7599
1.750
2.4053
7.6308
1.625
2.0739
6.5797
1.500
1.7671
5.6063
Brake Horsepower Required

GPM
per
RPM
2.4028
2.1984
2.0996
2.0031
1.8169
1.6397
1.4717
1.3127
1.1628
1.0220
0.8903
0.7676
0.7097
0.6541
0.6007
0.5496
0.5008
0.4542
0.4099
0.3679
0.3282
0.2907
0.2555
0.2226
0.1919
0.1635

Max.
Press.
PSI
446
487
510
535
590
653
728
816
922
1048
1204
1396
1510
1638
1784
1950
2140
2359
2614
2912
3265
3686
4194
4814
5584
6000

Metric Units
Plunger
Plunger
Dia.
Area
mm
cm2
146
167.530
140
153.279
137
146.391
133
139.661
127
126.677
121
114.326
114
102.608
108
91.524
102
81.073
95
71.256
89
62.072
83
53.521
79
49.483
76
45.604
73
41.883
70
38.320
67
34.915
64
31.669
60
28.581
57
25.652
54
22.881
51
20.268
48
17.814
44
15.518
41
13.380
38
11.401
Kilowatts Required

L/Sec.
per
RPM
0.1516
0.1387
0.1325
0.1264
0.1146
0.1035
0.0928
0.0828
0.0734
0.0645
0.0562
0.0484
0.0448
0.0413
0.0379
0.0347
0.0316
0.0287
0.0259
0.0232
0.0207
0.0183
0.0161
0.0140
0.0121
0.0103

100 * RPM
150 RPM
Max.
Press.
kPa M3/Hr L/Sec. M3/Hr L/Sec.
3075
54.6
15.2
81.9
22.7
3361
49.9
13.9
74.9
20.8
3519
47.7
13.2
71.5
19.9
3688
45.5
12.6
68.2
19.0
4066
41.3
11.5
61.9
17.2
4506
37.2
10.3
55.9
15.5
5020
33.4
9.3
50.1
13.9
5628
29.8
8.3
44.7
12.4
6354
26.4
7.3
39.6
11.0
7229
23.2
6.4
34.8
9.7
8299
20.2
5.6
30.3
8.4
9624
17.4
4.8
26.1
7.3
10410 16.1
4.5
24.2
6.7
11295 14.9
4.1
22.3
6.2
12299 13.6
3.8
20.5
5.7
13442 12.5
3.5
18.7
5.2
14753 11.4
3.2
17.1
4.7
16265 10.3
2.9
15.5
4.3
18022
9.3
2.6
14.0
3.9
20081
8.4
2.3
12.5
3.5
22512
7.5
2.1
11.2
3.1
25414
6.6
1.8
9.9
2.8
28916
5.8
1.6
8.7
2.4
33194
5.1
1.4
7.6
2.1
38498
4.4
1.2
6.5
1.8
41369
3.7
1.0
5.6
1.5
52
78

M3/Hr
per
RPM
0.5457
0.4993
0.4768
0.4549
0.4126
0.3724
0.3342
0.2981
0.2641
0.2321
0.2022
0.1743
0.1612
0.1485
0.1364
0.1248
0.1137
0.1032
0.0931
0.0836
0.0745
0.0660
0.0580
0.0505
0.0436
0.0371

100 * RPM

BPD
8239
7538
7199
6868
6230
5622
5046
4501
3987
3504
3053
2632
2434
2243
2060
1885
1717
1558
1406
1262
1126
997
876
764
658
561

GPM
240.3
219.8
210.0
200.3
181.7
164.0
147.2
131.3
116.3
102.2
89.0
76.8
71.0
65.4
60.1
55.0
50.1
45.4
41.0
36.8
32.8
29.1
25.5
22.3
19.2
16.4
70

150 RPM

BPD GPM
12358 360.4
11307 329.8
10799 314.9
10302 300.5
9344
272.5
8433
246.0
7569
220.7
6751
196.9
5981
174.4
5256
153.3
4579
133.5
3948
115.1
3650
106.5
3364
98.1
3090
90.1
2827
82.4
2576
75.1
2336
68.1
2109
61.5
1893
55.2
3067
49.2
2717
43.6
2388
38.3
2293
33.4
1977
28.8
1685
24.5
105

175 RPM

BPD
14417
13191
12598
12019
10902
9839
8830
7877
6977
6132
5342
4606
4259
3925
3605
3298
3005
2726
2460
2208
1970
1745
1533
1336
1152
982

GPM
420.5
384.7
367.4
350.5
318.0
287.0
257.5
229.7
203.5
178.8
155.8
134.3
124.2
114.5
105.1
96.2
87.6
79.5
71.7
64.4
57.4
50.9
44.7
38.9
33.6
28.6
122

175 RPM

M3/Hr
95.5
87.4
83.4
79.6
72.2
65.2
58.5
52.2
46.2
40.6
35.4
30.5
28.2
26.0
23.9
21.8
19.9
18.1
16.3
14.6
13.0
11.6
10.2
8.8
7.6
6.5

L/Sec.
26.5
24.3
23.2
22.1
20.1
18.1
16.2
14.5
12.8
11.3
9.8
8.5
7.8
7.2
6.6
6.1
5.5
5.0
4.5
4.1
3.6
3.2
2.8
2.5
2.1
1.8
91

200 RPM

BPD
16477
15075
14398
13736
12459
11244
10092
9002
7974
7008
6105
5264
4867
4486
4120
3769
3434
3115
2811
2523
2251
1994
1752
1527
1316
1122

GPM
480.6
439.7
419.9
400.6
363.4
327.9
294.3
262.5
232.6
204.4
178.1
153.5
141.9
130.8
120.1
109.9
100.2
90.8
82.0
73.6
65.6
58.1
51.1
44.5
38.4
32.7
139

200 RPM

M3/Hr
109.1
99.9
95.4
91.0
82.5
74.5
66.8
59.6
52.8
46.4
40.4
34.9
32.2
29.7
27.3
25.0
22.7
20.6
18.6
16.7
14.9
13.2
11.6
10.1
8.7
7.4

225 RPM

BPD
18536
16960
16198
15453
14016
12650
11353
10127
8971
7884
6868
5922
5475
5046
4634
4240
3864
3504
3163
2839
2532
2243
1971
1717
1481
1262

GPM
540.6
494.6
472.4
450.7
408.8
368.9
331.1
295.4
261.6
229.9
200.3
172.7
159.7
147.2
135.2
123.7
112.7
102.2
92.2
82.8
73.8
65.4
57.5
50.1
43.2
36.8
157

225 RPM

265 RPM

BPD
21832
19975
19077
18200
16508
14899
13372
11927
10565
9286
8089
6975
6449
5943
5458
4994
4550
4127
3725
3343
2982
2642
2322
2023
1744
1486

GPM
636.7
582.6
556.4
530.8
481.5
434.5
390.0
347.9
308.1
270.8
235.9
203.4
188.1
173.3
159.2
145.6
132.7
120.4
108.6
97.5
87.0
77.0
67.7
59.0
50.9
43.3
184

265 RPM

L/Sec. M3/Hr L/Sec. M3/Hr L/Sec.


30.3
122.8
34.1
144.6
40.2
27.7
112.3
31.2
132.3
36.8
26.5
107.3
29.8
126.4
35.1
25.3
102.4
28.4
120.5
33.5
22.9
92.8
25.8
109.3
30.4
20.7
83.8
23.3
98.7
27.4
18.6
75.2
20.9
88.6
24.6
16.6
67.1
18.6
79.0
21.9
14.7
59.4
16.5
70.0
19.4
12.9
52.2
14.5
61.5
17.1
11.2
45.5
12.6
53.6
14.9
9.7
39.2
10.9
46.2
12.8
9.0
36.3
10.1
42.7
11.9
8.3
33.4
9.3
39.4
10.9
7.6
30.7
8.5
36.2
10.0
6.9
28.1
7.8
33.1
9.2
6.3
25.6
7.1
30.1
8.4
5.7
23.2
6.4
27.3
7.6
5.2
20.9
5.8
24.7
6.9
4.6
18.8
5.2
22.1
6.2
4.1
16.8
4.7
19.7
5.5
3.7
14.9
4.1
17.5
4.9
3.2
13.1
3.6
15.4
4.3
2.8
11.4
3.2
13.4
3.7
2.4
9.8
2.7
11.5
3.2
2.1
8.4
2.3
9.8
2.7
104
117
137

Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on 90% Mechanical Efficiency.
*Operation below 150 RPM requires an optional externally-mounted electric motor-driven auxillary lubrication system.
The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own
evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that
stipulated in National Oilwell Standard Terms and Conditions of Sale.

Authorized Distributor:

www.natoil.com / customer.service@natoil.com
10000 Richmond, Houston, Texas 77042
(713)346-7500 (phone) (713)346-7366 (fax)

200T-5 Triplex Plunger Pump


5 11/16
11 1/8

9 1/4

4.875
4.873

Specifications

7/8 " x 7/16 KEYWAY


3.500
3.499

DIA.

DIA.
1 1/4 " x 5/8 " KEYWAY

30 5/8

SUCTION AND DISCHARGE


CONNECTIONS MAY BE
MADE AT EITHER END

18 5/16

7 1/2

"C"

55 1/2

7 1/2

13 1/8

13 1/8

6
5 5/8

SHAFT EXTENSION
FOR DIRECT DRIVE

1 1/8 " DIA. HOLE THRU


4 PLACES, AS SHOWN

1 1/4 " x 5/8 " KEYWAY


4.875
4.873

DIA.

16 3/4

"D"
36 1/2

31 1/4

CENTERLINE
DISCHARGE

"B"

7
9

12 1/4
4 1/2

1 1/2 " STD. PIPE TAP


MUD TRAP DRAIN
3 3/4

7 3/4

19 3/4

"F"

CENTERLINE
SUCTION

2 1/4

1" STD. PIPE TAP


POWER END OIL DRAIN

"A"

1 1/2 " STD. PIPE TAP


CRADLE DRAIN, BOTH SIDES

Pump Size
maximum plunger size x stroke length in.(mm):
4 x 5 (102 x 127)
Rated bhp at 400 rpm (kw): 200 (149.1)
Rated plunger load, pounds(Kg): 11,870(5384.2)
Maximum discharge pressure: psi(kPa)
L model: 1680 (11,583)
M model: 3350 (23097)
H model: 5000 (34,474)
Crankshaft extension: in.(mm)
Diameter: 4.875 (123.8)
Length long side: 11.75 (298.0)
Length short side: 5-5/8 (142.9)
Keyway (width x depth):
1 1/4 x 5/8 (32 x 16)
Maximum recommended sheave
in.(mm): 58 (1473)
Minimum recommended sheave
in.(mm): 36 (914)
For larger sizes: Contact Customer Service
Pinion shaft extension,
if gear reducer is supplied in.(mm)
For belt or chain drive:
Contact Customer Service
For direct drive: Diameter: 3.5 (88.9)
Length: 5-11/16 (144.5)
Keyway (width x depth):
7/8 x 7/16 (22.2 x 11.1)
Accessory gear reduction unit:
2.27:1, 2.89:1, 3.25:1, 3.36:1, 3.69:1,
4.38:1, 4.84:1, 5.63:1
Oil Capacity, gallons (L)
Crankcase: 6 1/2 (24.6)
Gear Reducer-varies with ratio:
3.5 to 6.5 (13.2 to 24.6)
Weight, pump only on
wood shipping skids pounds (Kg):
4486 (2035)
Gear reducer, approximate pounds (Kg):
1100 (499)

2" STD. PIPE TAP


CRADLE DRAIN

40 3/4
"E"

Pump Model
200T-5L
200T-5M
200T-5H

Flange Connections
Discharge Connection Sizes Suction Connection Sizes
3 (76.2) API-2000 RJ
6 (152.4) ANSI-150 FF
2 (50.8) API-5000 RJ
4 (101.6) ANSI-150 FF
2 (50.8) ANSI-2500 RJ
3 (76.2) API-2000 RJ

A
5 11/16
4 3/4
4 3/4

Dimensions in inches
B
C
D
7 5/8
27 3/4
48 3/4
6 1/2
26 1/2
48 3/8
6 1/2
26 1/2
48 3/8

(mm)
E
65 3/4
64 7/8
64 1/4

F
23
25 5/16
25 5/16

200T-5 Triplex Plunger Pump


Performance Data
PUMP

200T-5L

200T-5M

200T-5H

PUMP

200T-5L

200T-5M

200T-5H

English Units
Plunger
Plunger
BPD
Dia.
Area
per
In.
Sq. In.
RPM
4.000
12.5664
27.9770
3.750
11.0447
24.5892
3.500
9.6211
21.4199
3.250
8.2958
18.4692
3.000
7.0686
15.7371
2.750
5.9396
13.2235
2.625
5.4119
12.0487
2.500
4.9087
10.9285
2.375
4.4301
9.8630
2.250
3.9761
8.8521
2.125
3.5466
7.8959
2.000
3.1416
6.9943
1.875
2.7612
6.1473
1.750
2.4053
5.3550
1.375
1.4849
3.3059
1.250
1.2272
2.7321
Brake Horsepower Required

GPM
per
RPM
0.8160
0.7172
0.6247
0.5387
0.4590
0.3857
0.3514
0.3187
0.2877
0.2582
0.2303
0.2040
0.1793
0.1562
0.0964
0.0797

Metric Units
Plunger
Plunger
Dia.
Area
mm
cm2
102
81.073
95
71.256
89
62.072
83
53.521
76
45.604
70
38.320
67
34.915
64
31.669
60
28.581
57
25.652
54
22.881
51
20.268
48
17.814
44
15.518
35
9.580
32
7.917
Kilowatts Required

L/Sec.
per
RPM
0.0515
0.0452
0.0394
0.0340
0.0290
0.0243
0.0222
0.0201
0.0181
0.0163
0.0145
0.0129
0.0113
0.0099
0.0061
0.0050

M3/Hr
per
RPM
0.1853
0.1629
0.1419
0.1223
0.1042
0.0876
0.0798
0.0724
0.0653
0.0586
0.0523
0.0463
0.0407
0.0355
0.0219
0.0181

100 RPM
Max.
Press.
PSI
945
1075
1234
1431
1680
1998
2193
2418
2679
2985
3350
3778
4299
4935
5000
5000

BPD
2798
2459
2142
1847
1574
1323
1205
1093
987
886
790
700
615
536
331
274

GPM
81.6
71.7
62.5
53.9
45.9
38.6
35.1
31.9
28.8
25.8
23.0
20.4
17.9
15.6
9.6
8.0
50

200 RPM

BPD
5596
4918
4284
3694
3148
2645
2410
2186
1973
1771
1580
1399
1230
1071
662
547

250 RPM

GPM
163.2
143.4
124.9
107.7
91.8
77.1
70.3
63.7
57.5
51.6
46.1
40.8
35.9
31.2
19.3
15.9
100

BPD
6995
6148
5355
4618
3935
3306
3013
2733
2466
2214
1974
1749
1537
1339
827
684

GPM
204.0
179.3
156.2
134.7
114.7
96.4
87.9
79.7
71.9
64.5
57.6
51.0
44.8
39.0
24.1
19.9

300 RPM

BPD
8394
7377
6426
5541
4722
3968
3615
3279
2959
2656
2369
2099
1845
1607
992
820

125

100 RPM
200 RPM
Max.
Press.
kPa M3/Hr L/Sec. M3/Hr L/Sec.
6513
18.5
5.1
37.1
10.3
7410
16.3
4.5
32.6
9.0
8506
14.2
3.9
28.4
7.9
9865
12.2
3.4
24.5
6.8
11583 10.4
2.9
20.8
5.8
13779
8.8
2.4
17.5
4.9
15123
8.0
2.2
16.0
4.4
16673
7.2
2.0
14.5
4.0
18474
6.5
1.8
13.1
3.6
20583
5.9
1.6
11.7
3.3
23097
5.2
1.5
10.5
2.9
26051
4.6
1.3
9.3
2.6
29640
4.1
1.1
8.1
2.3
34026
3.5
1.0
7.1
2.0
34474
2.2
0.6
4.4
1.2
34474
1.8
0.5
3.6
1.0
37
75

250 RPM

M3/Hr
46.3
40.7
35.5
30.6
26.1
21.9
20.0
18.1
16.3
14.7
13.1
11.6
10.2
8.9
5.5
4.5

L/Sec.
12.9
11.3
9.9
8.5
7.2
6.1
5.5
5.0
4.5
4.1
3.6
3.2
2.8
2.5
1.5
1.3
93

GPM
244.8
215.2
187.4
161.6
137.7
115.7
105.4
95.6
86.3
77.5
69.1
61.2
53.8
46.9
28.9
23.9
150

300 RPM

M3/Hr
55.6
48.9
42.6
36.7
31.3
26.3
23.9
21.7
19.6
17.6
15.7
13.9
12.2
10.6
6.6
5.4

350 RPM

BPD
9792
8607
7497
6465
5508
4629
4218
3825
3453
3099
2764
2448
2152
1875
1158
957

GPM
285.6
251.0
218.7
188.5
160.6
135.0
123.0
111.6
100.7
90.4
80.6
71.4
62.8
54.7
33.7
27.9
175

350 RPM

400 RPM

BPD
GPM
11191* 326*
9836
286.9
8568
249.9
7388
215.5
6295
183.6
5290
154.3
4820
140.6
4372
127.5
3946
115.1
3541
103.3
3159
92.1
2798
81.6
2459
71.7
2142
62.5
1323
38.6
1093
31.9
200

400 RPM

L/Sec. M3/Hr L/Sec. M3/Hr L/Sec.


15.4
64.9
18.0
74.1*
20.6*
13.6
57.0
15.8
65.1
18.1
11.8
49.7
13.8
56.8
15.8
10.2
42.8
11.9
48.9
13.6
8.7
36.5
10.1
41.7
11.6
7.3
30.7
8.5
35.0
9.7
6.7
27.9
7.8
31.9
8.9
6.0
25.3
7.0
29.0
8.0
5.4
22.9
6.4
26.1
7.3
4.9
20.5
5.7
23.5
6.5
4.4
18.3
5.1
20.9
5.8
3.9
16.2
4.5
18.5
5.1
3.4
14.3
4.0
16.3
4.5
3.0
12.4
3.4
14.2
3.9
1.8
7.7
2.1
8.8
2.4
1.5
6.3
1.8
7.2
2.0
112
130
149

Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on 90% Mechanical Efficiency. For Operations below 200 RPM, an auxiliary lubrication system is required. Not all plunger sizes are shown. Contact National-Oilwell for additional information. Spherical Valves must be installed when the pump is fitted with 4.0 (102mm) plungers
The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own
evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that
stipulated in National Oilwell Standard Terms and Conditions of Sale.

Authorized Distributor:

www.natoil.com / customer.service@natoil.com
10000 Richmond, Houston, Texas 77042
(713)346-7500 (phone) (713)346-7366 (fax)

202T-6 Triplex Plunger Pump


1.250

Specifications

DIA. AUXILIARY
DRIVE SHAFT
1" DIA. HOLE THRU
4 PLACES AS SHOWN

2 3/4
25 1/2
21 1/4
E
FACE OF
SUCTION

12

F
FACE OF
DISCHARGE

24
51 1/2
E
FACE OF
SUCTION
26
6 1/2
4

5 1/2
8 3/4

1" x 3/8" KEYWAY

4.495

4 1/2

DIA

12" TO REMOVE VALVES

D
C
14 1/4
3/8
B
24

4
11 1/2

2 1/2

5 1/2

39
51

7 5/8

16" TO REMOVE
PLUNGERS

73 1/8
9" TO REMOVE CONNECTING
RODS AND CROSSHEADS

Pump Model
202T-6L
202T-6M
202T-6H

F
FACE OF
DISCHARGE

Pump Size
maximum plunger size x stroke length, in.(mm):
4 1/4 x 6 (107.9 x 152.4)
Rated bhp at 320 rpm (kw): 202 (150.58)
Rated plunger load, pounds(Kg): 12,500(5670)
Maximum discharge pressure: psi(kPa)
L model: 1500 (10,342)
M model: 3180 (21,925)
Crankshaft extension: in.(mm)
Diameter: 4.495 (114.17)
Length: 8 3/4 (222.25)
Keyway (width x depth):
1 x 3/8 (25.4 x 9.53)
Maximum recommended sheave,
in.(mm): 58 (1473)
Minimum recommended sheave,
in.(mm): 36 (914)
For larger sizes: Contact Customer Service
Pinion shaft extension,
if gear reducer is supplied, in.(mm)
For belt or chain drive:
Contact Customer Service
For direct drive: Diameter: 3.438 (87.33)
Length: 7 3/8 (187.33)
Keyway (width x depth):
7/8 x 7/16 (22.2 x 11.1)
Accessory gear reduction unit:
1.59:1, 1.78:1, 2.487:1, 3.12:1,
4.44:1, 5.48:1
Oil Capacity, gallons (L)
Crankcase: 34 (128.7)
Gear Reducer: Varies with ratio
Weight, pump only on
wood shipping skids pounds (Kg):
3952 (1792.60)

2"NPT CRADLE DRAIN


(BOTH SIDES)

Flange Connections
Discharge Connection Sizes Suction Connection Sizes
3 ANSI-600 L.R.
6 ANSI-150 F.F.
2 1/2 ANSI-1500 L.R.
4 ANSI-150 F.F.
2 SCH. 160 PIPE BEVELED FOR WELD
4 ANSI-300 R.F.

A
1 3/4
2 1/2

Dimensions (Inches)
B
C
D
E
3 3/4
22 1/4
28 5/8
13 1/2
5 3/4
22
28 1/4
16
3
22 1/4
28 5/8
17

F
13 1/2
16
18 1/4

202T-6 Triplex Plunger Pump


Performance Data
PUMP

202T-6L

202T-6M

PUMP

202T-6L

202T-6M

English Units
Plunger
Plunger
BPD
Dia.
Area
per
In.
Sq. In.
RPM
4.250
14.1862
37.9001
4.125
13.3640
35.7035
4.000
12.5664
33.5725
3.875
11.7932
31.5070
3.750
11.0447
29.5070
3.625
10.3206
27.5727
3.500
9.6211
25.7039
3.375
8.9462
23.9007
3.250
8.2958
22.1631
3.125
7.6699
20.4910
3.000
7.0686
18.8845
3.000
7.0686
18.8845
2.875
6.4918
17.3436
2.750
5.9396
15.8682
2.625
5.4119
14.4584
2.500
4.9087
13.1142
2.000
3.1416
8.3931
Brake Horsepower Required

GPM
per
RPM
1.1054
1.0414
0.9792
0.9190
0.8606
0.8042
0.7497
0.6971
0.6464
0.5977
0.5508
0.5508
0.5059
0.4628
0.4217
0.3825
0.2448

Metric Units
Plunger
Plunger
Dia.
Area
mm
cm2
108
91.524
105
86.219
102
81.073
98
76.085
95
71.256
92
66.584
89
62.072
86
57.717
83
53.521
79
49.483
76
45.604
76
45.604
73
41.883
70
38.320
67
34.915
64
31.669
51
20.268
Kilowatts Required

L/Sec.
per
RPM
0.0697
0.0657
0.0618
0.0580
0.0543
0.0507
0.0473
0.0440
0.0408
0.0377
0.0347
0.0347
0.0319
0.0292
0.0266
0.0241
0.0154

M3/Hr
per
RPM
0.2510
0.2365
0.2224
0.2087
0.1954
0.1826
0.1703
0.1583
0.1468
0.1357
0.1251
0.1251
0.1149
0.1051
0.0958
0.0869
0.0556

100 RPM
Max.
Press.
PSI
881
935
995
1060
1132
1211
1299
1397
1500
1500
1500
1768
1926
2105
2310
2546
3180

BPD
3791
3571
3358
3151
2951
2758
2571
2391
2217
2050
1889
1889
1735
1587
1446
1312
840

GPM
110.5
104.1
97.9
91.9
86.1
80.4
75.0
69.7
64.6
59.8
55.1
55.1
50.6
46.3
42.2
38.2
24.5
64

150 RPM

BPD
5686
5356
5036
4727
4427
4136
3856
3586
3325
3074
2833
2833
2602
2381
2169
1968
1259

200 RPM

GPM
165.8
156.2
146.9
137.8
129.1
120.6
112.5
104.6
97.0
89.6
82.6
82.6
75.9
69.4
63.3
57.4
36.7

BPD
7581
7141
6715
6302
5902
5515
5141
4781
4433
4099
3777
3777
3469
3174
2892
2623
1679

81

100 RPM
150 RPM
Max.
Press.
kPa M3/Hr L/Sec. M3/Hr L/Sec.
6075
25.1
7.0
37.7
10.5
6449
23.6
6.6
35.5
9.9
6858
22.2
6.2
33.4
9.3
7308
20.9
5.8
31.3
8.7
7803
19.5
5.4
29.3
8.1
8351
18.3
5.1
27.4
7.6
8958
17.0
4.7
25.5
7.1
9634
15.8
4.4
23.7
6.6
10342 14.7
4.1
22.0
6.1
10342 13.6
3.8
20.4
5.7
10342 12.5
3.5
18.8
5.2
12193 12.5
3.5
18.8
5.2
13276 11.5
3.2
17.2
4.8
14510 10.5
2.9
15.8
4.4
15925
9.6
2.7
14.4
4.0
17557
8.7
2.4
13.0
3.6
21925
5.6
1.5
8.3
2.3
48
60

GPM
221.1
208.3
195.8
183.8
172.1
160.8
149.9
139.4
129.3
119.5
110.2
110.2
101.2
92.6
84.3
76.5
49.0
127

200 RPM

M3/Hr
50.2
47.3
44.5
41.7
39.1
36.5
34.1
31.7
29.4
27.1
25.0
25.0
23.0
21.0
19.2
17.4
11.1

L/Sec.
13.9
13.1
12.4
11.6
10.9
10.1
9.5
8.8
8.2
7.5
6.9
6.9
6.4
5.8
5.3
4.8
3.1
95

250 RPM

BPD
9476
8926
8394
7877
7377
6894
6426
5976
5541
5123
4722
4722
4336
3968
3615
3279
2099

GPM
276.4
260.3
244.8
229.7
215.2
201.1
187.4
174.3
161.6
149.4
137.7
137.7
126.5
115.7
105.4
95.6
61.2
158

250 RPM

M3/Hr
62.8
59.1
55.6
52.2
48.9
45.7
42.6
39.6
36.7
33.9
31.3
31.3
28.7
26.3
23.9
21.7
13.9

300 RPM

BPD
11371
10712
10072
9453
8853
8272
7712
7171
6649
6148
5666
5666
5204
4761
4338
3935
2518

GPM
331.6
312.4
293.8
275.7
258.2
241.3
224.9
209.1
193.9
179.3
165.2
165.2
151.8
138.8
126.5
114.7
73.4
189

300 RPM

320 RPM

BPD
GPM
12129 353.7
11426 333.2
10744 313.3
10083 294.1
9443
275.4
8824
257.3
8226
239.9
7649
223.1
7093
206.9
6558
191.2
6044
176.3
6044
176.3
5550
161.9
5078
148.1
4627
134.9
4197
122.4
2686
78.3
202

320 RPM

L/Sec. M3/Hr L/Sec. M3/Hr L/Sec.


17.4
75.3
20.9
80.3
22.3
16.4
70.9
19.7
75.7
21.0
15.4
66.7
18.5
71.2
19.8
14.5
62.6
17.4
66.8
18.6
13.6
58.6
16.3
62.5
17.4
12.7
54.8
15.2
58.4
16.2
11.8
51.1
14.2
54.5
15.1
11.0
47.5
13.2
50.7
14.1
10.2
44.0
12.2
47.0
13.1
9.4
40.7
11.3
43.4
12.1
8.7
37.5
10.4
40.0
11.1
8.7
37.5
10.4
40.0
11.1
8.0
34.5
9.6
36.8
10.2
7.3
31.5
8.8
33.6
9.3
6.7
28.7
8.0
30.6
8.5
6.0
26.1
7.2
27.8
7.7
3.9
16.7
4.6
17.8
4.9
118
141
151

Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on 90% Mechanical Efficiency. Not all plunger sizes are shown. Contact National-Oilwell for
additional information. For Operations below 120 RPM, an auxiliary lubrication system is required.
The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own
evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that
stipulated in National Oilwell Standard Terms and Conditions of Sale.

Authorized Distributor:

www.natoil.com / customer.service@natoil.com
10000 Richmond, Houston, Texas 77042
(713)346-7500 (phone) (713)346-7366 (fax)

217Q-4 Quintuplex Plunger Pump


INTERNAL LUBE PUMP

Specifications

PRESSURE GAUGE

25.29

14.00
TYP

C
28.00
TYP

C/2
19.22

.75
TYP
4 PLACES

10.50

1.000 x .500 KEYWAY


9.000 LONG

4.250
4.249

ROTATION
DIRECTION

DISCHARGE
CONNECTION

F
A
20.42

1.00

10.00

Pump Size:
maximum plunger size x stroke length, in.(mm):
3.375 x 4.500 (85.725 x 114.3)
Rated BHP (kW) at 390 RPM: 217 (162)
Rated plunger load, pounds (kg): 8800(3992)
Maximum discharge pressure: psi (kPa)
L model: 1440 (9929)
M model: 3600 (24821)
H model: 6000 (41369)
Crankshaft extension:
Diameter, in.(mm): 4.250 (107.95)
Length, in.(mm): 10.50 (266.7)
Keyway width x depth, in.(mm):
1 x 1/2 (25.4 x 38.1)
Maximum recommended sheave diameter,
in.(mm): 53 (1346.2)
For larger sizes: Contact Customer Service
Pinion shaft extension,
if gear reducer is supplied, in.(mm)
For belt or chain drive: N/A
For direct drive: Diameter: 2.500 (63.5)
Length: 5.000 (127.0)
Keyway (width x length):
5/8 x 5/16 (15.88 x7.94)
Accessory gear reduction unit:
2.06:1, 2.26:1, 3.60:1, 4.25:1, 4.65:1,
4.88:1, 5.13:1, 5.40:1, 5.69:1
Oil Capacity, gallons (L)
Crankcase: 7 (26.5)
Gear Reducer - varies with ratio:
2.00 to 2.25 (7.57 to 8.52)
Weight, pump only on
wood shipping skids, pounds (kg): 2948 (1337)
Standard Materials for Fluid Ends:
L & M models
Cast Nickel-Aluminum-Bronze
Cast Duplex Stainless Steel
Forged/Plate Carbon Steel
H model
Forged/Plate Carbon Steel
Forged 15-5 Stainless Steel
Forged Nickel-Aluminum-Bronze

G
.75

SUCTION
CONNECTION

5.25

24.25

9.89

Pump Model
217Q-4L
217Q-4M
217Q-4H

Flange Connections
Discharge Connection Sizes Suction Connection Sizes
3 (76.2)-600# ANSI FF
6 (152.4)-150# ANSI FF
2 (50.8)-1500# ANSI FF
4 (101.6)-300# ANSI FF
2 (50.8)-11 1/2 NPT
3 (76.2)-8 NPT

A
4 5/8
5 1/16
5 1/16

Dimensions (Inches)
B
C
D
E
7 7/8
33
33 3/8
49 7/16
5 7/8
33
33
38 3/4
6 3/16 31 1/2
33
39 3/4

F
9 5/8
9 1/2
10 3/4

G
3 3/8
7/8
-1 5/8

217Q-4 Quintuplex Plunger Pump


Performance Data
PUMP

217Q-4L
(HP200AL)

217Q-4M
(HP200AM)

217Q-4H
(HP200MS)

PUMP

217Q-4L
(HP200AL)

217Q-4M
(HP200AM)

217Q-4H
(HP200MS)

English Units
Plunger
Plunger
BPD
Dia.
Area
per
In.
Sq. In.
RPM
3.375
8.9462
29.8759
3.250
8.2958
27.7038
3.125
7.6699
25.6137
3.000
7.0686
23.6056
2.875
6.4918
21.6795
2.750
5.9396
19.8353
2.625
5.4119
18.0731
2.500
4.9087
16.3928
2.375
4.4301
14.7945
2.250
3.9761
13.2782
2.125
3.5466
11.8438
2.000
3.1416
10.4914
1.875
2.7612
9.2209
1.750
2.4053
8.0325
1.625
2.0739
6.9260
1.500
1.7671
5.9014
1.375
1.4849
4.9588
1.250
1.2272
4.0982
Brake Horsepower Required

GPM
per
RPM
0.8714
0.8080
0.7471
0.6885
0.6323
0.5785
0.5271
0.4781
0.4315
0.3873
0.3454
0.3060
0.2689
0.2343
0.2020
0.1721
0.1446
0.1195

Metric Units
Plunger
Plunger
Dia.
Area
mm
cm2
86
57.717
83
53.521
79
49.483
76
45.604
73
41.883
70
38.320
67
34.915
64
31.669
60
28.581
57
25.652
54
22.881
51
20.268
48
17.814
44
15.518
41
13.380
38
11.401
35
9.580
32
7.917
Kilowatts Required

L/Sec.
per
RPM
0.0550
0.0510
0.0471
0.0434
0.0399
0.0365
0.0333
0.0302
0.0272
0.0244
0.0218
0.0193
0.0170
0.0148
0.0127
0.0109
0.0091
0.0075

M3/Hr
per
RPM
0.1979
0.1835
0.1697
0.1564
0.1436
0.1314
0.1197
0.1086
0.0980
0.0880
0.0785
0.0695
0.0611
0.0532
0.0459
0.0391
0.0328
0.0271

100 * RPM
Max.
Press.
PSI
984
1061
1147
1245
1356
1440
1440
1793
1986
2213
2481
2801
3187
3600
4243
4980
5926
6000

BPD
2988
2771
2562
2361
2168
1984
1808
1640
1480
1328
1185
1050
923
804
693
591
496
410

GPM
87.1
80.8
74.7
68.8
63.2
57.9
52.7
47.8
43.2
38.7
34.5
30.6
26.9
23.4
20.2
17.2
14.5
12.0
56

150 RPM

BPD
4482
4156
3843
3541
3252
2976
2711
2459
2220
1992
1777
1574
1384
1205
1039
886
744
615

200 RPM

GPM
130.7
121.2
112.1
103.3
94.8
86.8
79.1
71.7
64.7
58.1
51.8
45.9
40.3
35.1
30.3
25.8
21.7
17.9

BPD
5976
5541
5123
4722
4336
3968
3615
3279
2959
2656
2369
2099
1845
1607
1386
1181
992
820

84

GPM
174.3
161.6
149.4
137.7
126.5
115.7
105.4
95.6
86.3
77.5
69.1
61.2
53.8
46.9
40.4
34.4
28.9
23.9

250 RPM

BPD
7469
6926
6404
5902
5420
4959
4519
4099
3699
3320
2961
2623
2306
2009
1732
1476
1240
1025

112

100 * RPM
150 RPM
Max.
Press.
kPa M3/Hr L/Sec. M3/Hr L/Sec.
6782
19.8
5.5
29.7
8.2
7314
18.4
5.1
27.5
7.6
7911
17.0
4.7
25.4
7.1
8584
15.6
4.3
23.5
6.5
9346
14.4
4.0
21.5
6.0
9929
13.1
3.6
19.7
5.5
9929
12.0
3.3
18.0
5.0
12360 10.9
3.0
16.3
4.5
13696
9.8
2.7
14.7
4.1
15260
8.8
2.4
13.2
3.7
17108
7.8
2.2
11.8
3.3
19313
6.9
1.9
10.4
2.9
21974
6.1
1.7
9.2
2.5
24821
5.3
1.5
8.0
2.2
29256
4.6
1.3
6.9
1.9
34335
3.9
1.1
5.9
1.6
40861
3.3
0.9
4.9
1.4
41369
2.7
0.8
4.1
1.1
42
63

200 RPM

M3/Hr
39.6
36.7
33.9
31.3
28.7
26.3
23.9
21.7
19.6
17.6
15.7
13.9
12.2
10.6
9.2
7.8
6.6
5.4

L/Sec.
11.0
10.2
9.4
8.7
8.0
7.3
6.7
6.0
5.4
4.9
4.4
3.9
3.4
3.0
2.5
2.2
1.8
1.5
84

GPM
217.8
202.0
186.8
172.1
158.1
144.6
131.8
119.5
107.9
96.8
86.4
76.5
67.2
58.6
50.5
43.0
36.2
29.9
139

250 RPM

M3/Hr
49.5
45.9
42.4
39.1
35.9
32.8
29.9
27.1
24.5
22.0
19.6
17.4
15.3
13.3
11.5
9.8
8.2
6.8

300 RPM

BPD
8963
8312
7685
7082
6504
5951
5422
4918
4439
3984
3554
3148
2767
2410
2078
1771
1488
1230

GPM
261.4
242.4
224.1
206.5
189.7
173.6
158.1
143.4
129.5
116.2
103.6
91.8
80.7
70.3
60.6
51.6
43.4
35.9
167

300 RPM

390 RPM

BPD
GPM
11652 339.8
10805 315.1
9990
291.4
9207
268.5
8455
246.6
7736
225.6
7049
205.6
6394
186.5
5770
168.3
5179
151.0
4620
134.7
4092
119.3
3597
104.9
3133
91.4
2702
78.8
2302
67.1
1934
56.4
1599
46.6
217

390 RPM

L/Sec. M3/Hr L/Sec. M3/Hr L/Sec.


13.7
59.4
16.5
77.2
21.4
12.7
55.1
15.3
71.6
19.9
11.8
50.9
14.1
66.2
18.4
10.9
46.9
13.0
61.0
16.9
10.0
43.1
12.0
56.0
15.6
9.1
39.4
10.9
51.2
14.2
8.3
35.9
10.0
46.7
13.0
7.5
32.6
9.0
42.3
11.8
6.8
29.4
8.2
38.2
10.6
6.1
26.4
7.3
34.3
9.5
5.4
23.5
6.5
30.6
8.5
4.8
20.8
5.8
27.1
7.5
4.2
18.3
5.1
23.8
6.6
3.7
16.0
4.4
20.7
5.8
3.2
13.8
3.8
17.9
5.0
2.7
11.7
3.3
15.2
4.2
2.3
9.9
2.7
12.8
3.6
1.9
8.1
2.3
10.6
2.9
104
124
162

Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on 90% Mechanical Efficiency. *Operation below 150 RPM requires an optional externallymounted electric motor-driven auxillary lubrication system.
The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own
evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that
stipulated in National Oilwell Standard Terms and Conditions of Sale.

Authorized Distributor:

www.natoil.com / customer.service@natoil.com
10000 Richmond, Houston, Texas 77042
(713)346-7500 (phone) (713)346-7366 (fax)

250T-5 Triplex Plunger Pump


Specifications

7/8" X 7/16" KEYWAY


5 11/16
9 1/4

3.500
3.499

11 1/8

4.875
4.873

DIA.

DIA.
1 1/4" X 5/8" KEYWAY

30 5/8

SUCTION AND DISCHARGE


CONNECTIONS MAY BE
MADE AT EITHER END

18 5/16
13 1/8

"C"

55 1/2

7 1/2

7 1/2
13 1/8

1 1/8" DIA. HOLE THRU

7
5 5/8

4.875
4.873

SHAFT EXTENSION
FOR DIRECT DRIVE

4 PLACES, AS SHOWN

1 1/4" X 5/8"KEYWAY

DIA.

16 3/4

"D"
36 1/2
1 1/2" STD. PIPE TAP
CRADLE DRAIN, BOTH SIDES

+
+

+
CENTERLINE
SUCTION

"B"

6"

12 1/4

9"

+
2 1/4

CENTERLINE
DISCHARGE
"A"

31 1/4

+
1 1/2" STD. PIPE TAP
MUD TRAP DRAIN
3 3/4

1" STD. PIPE TAP


POWER END OIL DRAIN

4 1/2

"F"

Pump Size
maximum plunger size x stroke length, in.(mm):
4 1/2 x 5 (114 x 127)
Rated bhp at 400 rpm (kw): 250 (187)
Rated plunger load, pounds(Kg): 14855(6738)
Maximum discharge pressure: psi(kPa)
L model: 1544 (10646)
M model: 3026 (20,865)
H model: 5000 (3,474)
Crankshaft extension: in.(mm)
Diameter: 4.875 (123.8)
Length long side: 11.75 (298.0)
Length short side: 5 5/8 (142.9)
Keyway (width x depth):
1 1/4 x 5/8 (32 x 16)
Maximum recommended sheave
in.(mm): 58 (1473)
Minimum recommended sheave
in.(mm): 36 (914)
For larger sizes: Contact Customer Service
Pinion shaft extension,
if gear reducer is supplied, in.(mm)
For belt or chain drive:
Contact Customer Service
For direct drive: Diameter: 3.5 (988.9)
Length: 5 11/16 (114.5)
Keyway (width x depth):
7/8 x 7/16 ((22.2 x 11.1)
Accessory gear reduction unit:
2.27:1, 2.89:1, 3.25:1, 3.36:1, 3.69:1,
4.38:1, 4.84:1, 5.63:1
Oil Capacity, gallons (L)
Crankcase: 6 1/2 (24.6)
Gear Reducer-varies with ratio:
3.5 to 6.5 (13.2 to 24.6)
Weight, pump only on
wood shipping skids, pounds (Kg):
4486 (2035)
Gear reducer, approximate pounds, (Kg):
1100 (499)

7 3/4

19 3/4

2" STD. PIPE TAP


CRADLE DRAIN

40 3/4
"E"

Pump Model
250T-5L
250T-5M
250T-5H

Flange Connections
Discharge Connection Sizes Suction Connection Sizes
3 (76.2) API-2000 RJ
6 (152.4) ANSI-150 FF
2 (50.8) API-5000 RJ
4 (101.6) ANSI-150 FF
2 (50.8) ANSI-2500 RJ
3 (76.2) API-2000 RJ

A
5 11/16
4 3/4
4 3/4

Dimensions in inches (mm)


B
C
D
E
7 5/8
27 3/4
48 3/4
65 3/4
6 1/2
26 1/2
48 3/8
64 7/8
6 1/2
26 1/2
48 3/8
64 1/4

F
23
25 5/16
25 5/16

250T-5 Triplex Plunger Pump


Performance Data
PUMP

250T-5L

250T-5M

250T-5H

PUMP

250T-5L

250T-5M

250T-5H

English Units
Plunger
Plunger
BPD
Dia.
Area
per
In.
Sq. In.
RPM
4.500
15.9043
35.4084
4.250
14.1862
31.5835
4.000
12.5664
27.9770
3.750
11.0447
24.5892
3.500
9.6211
21.4199
3.250
8.2958
18.4692
3.000
7.0686
15.7371
2.750
5.9396
13.2235
2.500
4.9087
10.9285
2.250
3.9761
8.8521
2.125
3.5466
7.8959
2.000
3.1416
6.9943
1.875
2.7612
6.1473
Brake Horsepower Required

GPM
per
RPM
1.0327
0.9212
0.8160
0.7172
0.6247
0.5387
0.4590
0.3857
0.3187
0.2582
0.2303
0.2040
0.1793

Metric Units
Plunger
Plunger
Dia.
Area
mm
cm2
114
102.608
108
91.524
102
81.073
95
71.256
89
62.072
83
53.521
76
45.604
70
38.320
64
31.669
57
25.652
54
22.881
51
20.268
48
17.814
Kilowatts Required

L/Sec.
per
RPM
0.0652
0.0581
0.0515
0.0452
0.0394
0.0340
0.0290
0.0243
0.0201
0.0163
0.0145
0.0129
0.0113

M3/Hr
per
RPM
0.2345
0.2092
0.1853
0.1629
0.1419
0.1223
0.1042
0.0876
0.0724
0.0586
0.0523
0.0463
0.0407

100 RPM
Max.
Press.
PSI
934
1047
1182
1345
1544
1791
2102
2501
3026
3736
4189
4728
5000

BPD
3541
3159
2798
2459
2142
1847
1574
1323
1093
886
790
700
615

GPM
103.3
92.1
81.6
71.7
62.5
53.9
45.9
38.6
31.9
25.8
23.0
20.4
17.9
63

200 RPM

BPD
7082
6317
5596
4918
4284
3694
3148
2645
2186
1771
1580
1399
1230

250 RPM

GPM
206.5
184.2
163.2
143.4
124.9
107.7
91.8
77.1
63.7
51.6
46.1
40.8
35.9
126

BPD
8853
7896
6995
6148
5355
4618
3935
3306
2733
2214
1974
1749
1537

GPM
258.2
230.3
204.0
179.3
156.2
134.7
114.7
96.4
79.7
64.5
57.6
51.0
44.8

300 RPM

BPD
10623
9476
8394
7377
6426
5541
4722
3968
3279
2656
2369
2099
1845

157

100 RPM
200 RPM
Max.
Press.
kPa M3/Hr L/Sec. M3/Hr L/Sec.
6440
23.5
6.5
46.9
13.0
7220
20.9
5.8
41.8
11.6
8151
18.5
5.1
37.1
10.3
9273
16.3
4.5
32.6
9.0
10646 14.2
3.9
28.4
7.9
12346 12.2
3.4
24.5
6.8
14490 10.4
2.9
20.8
5.8
17244
8.8
2.4
17.5
4.9
20865
7.2
2.0
14.5
4.0
25760
5.9
1.6
11.7
3.3
28879
5.2
1.5
10.5
2.9
32602
4.6
1.3
9.3
2.6
34474
4.1
1.1
8.1
2.3
47
94

250 RPM

M3/Hr L/Sec.
58.6
16.3
52.3
14.5
46.3
12.9
40.7
11.3
35.5
9.9
30.6
8.5
26.1
7.2
21.9
6.1
18.1
5.0
14.7
4.1
13.1
3.6
11.6
3.2
10.2
2.8
117

GPM
309.8
276.4
244.8
215.2
187.4
161.6
137.7
115.7
95.6
77.5
69.1
61.2
53.8
188

300 RPM

M3/Hr
70.4
62.8
55.6
48.9
42.6
36.7
31.3
26.3
21.7
17.6
15.7
13.9
12.2

350 RPM

BPD
12393
11055
9792
8607
7497
6465
5508
4629
3825
3099
2764
2448
2152

GPM
361.4
322.4
285.6
251.0
218.7
188.5
160.6
135.0
111.6
90.4
80.6
71.4
62.8
219

350 RPM

400 RPM

BPD

GPM

12634
11191
9836
8568
7388
6295
5290
4372
3541
3159
2798
2459

368.5
326.4
286.9
249.9
215.5
183.6
154.3
127.5
103.3
92.1
81.6
71.7
250

400 RPM

L/Sec. M3/Hr L/Sec. M3/Hr L/Sec.


19.5
82.1
22.8
17.4
73.2
20.3
83.7
23.2
15.4
64.9
18.0
74.1
20.6
13.6
57.0
15.8
65.1
18.1
11.8
49.7
13.8
56.8
15.8
10.2
42.8
11.9
48.9
13.6
8.7
36.5
10.1
41.7
11.6
7.3
30.7
8.5
35.0
9.7
6.0
25.3
7.0
29.0
8.0
4.9
20.5
5.7
23.5
6.5
4.4
18.3
5.1
20.9
5.8
3.9
16.2
4.5
18.5
5.1
3.4
14.3
4.0
16.3
4.5
140
163
187

Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on 90% Mechanical Efficiency. For Operations below 200 RPM, an auxiliary lubrication
system is required. Not all plunger sizes are shown. Contact National-Oilwell for additional information. Spherical Valves must be installed when the pump is fitted with 4.0 (102mm) plungers.
Contact Factory for flow rates not listed above.
The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own
evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that
stipulated in National Oilwell Standard Terms and Conditions of Sale.

Authorized Distributor:

www.natoil.com / customer.service@natoil.com
10000 Richmond, Houston, Texas 77042
(713)346-7500 (phone) (713)346-7366 (fax)

267Q-6 Quintuplex Plunger Pump


Specifications

FACE OF SUCTION & DISCHARGE

CLPUMP

32 7/8

24 1/2

19 5/8

CLCRANK

66 3/8

19 5/8

24 1/2

32 7/8

33 1/2

56" TO REMOVE CRANKSHAFT (EITHER SIDE)

7 1/4
1" DIA. HOLE THRU
6 PLACES AS SHOWN
1" x 3/8" KEYWAY
4.495

DIA

4.495

28 1/2

CENTERLINE
DISCHARGE

10 5/8

14

24 5/8
C

9" TO REMOVE
CONNECTING
RODS AND
CROSSHEADS

14 1/4

CENTERLINE
SUCTION

Pump Size
maximum plunger size x stroke length, in.(mm):
4 1/4 x 6 (107.0 x 152.4)
Rated bhp at 360 rpm (kw): 267 (199.04)
Rated plunger load, pounds(Kg): 10,000(4536)
Maximum discharge pressure: psi (kPa)
L model: 1420 (9791)
M model: 3180 (21,925)
Crankshaft extension: in.(mm)
Diameter: 4.495 (114.17)
Length: 7 1/4 (173.0)
Keyway (width x depth):
1 x 3/8 (25.4 x 9.53)
Maximum recommended sheave
in.(mm): 58 (1473)
Minimum recommended sheave
in.(mm): 36 (914)
For larger sizes: Contact Customer Service
Pinion shaft extension,
if gear reducer is supplied, in.(mm)
For belt or chain drive:
Contact Customer Servicey
For direct drive: Diameter: 3.375 (85.73)
Length: 4 1/2 (114.3)
Keyway (width x depth):
7/8 x 7/16 (22.2 x 11.1)
Accessory gear reduction unit:
2.698:1, 3.680:1, 5.50:1, 7.316:1, 9.50:1
Oil Capacity, gallons (L)
Crankcase: 32 (121.3)
Gear Reducer-varies with ratio:
5 1/4 to 7 1/2 (18.7 to 26.7)
Weight, pump only on
wood shipping skids, pounds (Kg):
6340 (2875.77)
Gear unit, approximate pounds (Kg):
2219 (1006.52)

14 5/8

51

73 7/16

Pump Model
267Q-6L
267Q-6M

Flange Connections
Discharge Connection Sizes Suction Connection Sizes
4 ANSI-600# L.R.
6 ANSI-300# F.F.
3 ANSI-1500# L.R.
4 ANSI-300# F.F.

Dimensions in inches (mm)


A
B
C
D
4 1/2 22 7/8
1 3/4
29 3/4
5 5/8 22 3/8
28 7/8

267Q-6 Quintuplex Plunger Pump


Performance Data
PUMP

267Q-6L

267Q-6M

PUMP

267Q-6L

267Q-6M

English Units
Plunger
Plunger
BPD
Dia.
Area
per
In.
Sq. In.
RPM
4.250
14.1862
63.1669
4.125
13.3640
59.5059
4.000
12.5664
55.9541
3.875
11.7932
52.5116
3.750
11.0447
49.1784
3.625
10.3206
45.9545
3.500
9.6211
42.8398
3.375
8.9462
39.8345
3.250
8.2958
36.9384
3.125
7.6699
34.1517
3.000
7.0686
31.4742
3.000
7.0686
31.4742
2.875
6.4918
28.9060
2.750
5.9396
26.4470
2.625
5.4119
24.0974
2.500
4.9087
21.8571
2.375
4.4301
19.7260
2.250
3.9761
17.7042
2.125
3.5466
15.7917
2.000
3.1416
13.9885
Brake Horsepower Required

GPM
per
RPM
1.8424
1.7356
1.6320
1.5316
1.4344
1.3403
1.2495
1.1618
1.0774
0.9961
0.9180
0.9180
0.8431
0.7714
0.7028
0.6375
0.5753
0.5164
0.4606
0.4080

Metric Units
Plunger
Plunger
Dia.
Area
mm
cm2
108
91.524
105
86.219
102
81.073
98
76.085
95
71.256
92
66.584
89
62.072
86
57.717
83
53.521
79
49.483
76
45.604
76
45.604
73
41.883
70
38.320
67
34.915
64
31.669
60
28.581
57
25.652
54
22.881
51
20.268
Kilowatts Required

L/Sec.
per
RPM
0.1162
0.1095
0.1030
0.0966
0.0905
0.0846
0.0788
0.0733
0.0680
0.0628
0.0579
0.0579
0.0532
0.0487
0.0443
0.0402
0.1307
3.5603
1.7410
0.0257

M3/Hr
per
RPM
0.4184
0.3942
0.3706
0.3478
0.3257
0.3044
0.2838
0.2639
0.2447
0.2262
0.2085
0.2085
0.1915
0.1752
0.1596
0.1448
3.9669
1.9519
0.2089
0.0927

100 RPM
Max.
Press.
PSI
705
748
796
848
905
969
1039
1118
1205
1304
1420
1420
1540
1684
1848
2037
2257
2515
2820
3180

BPD
6317
5951
5596
5252
4918
4596
4284
3984
3694
3416
3148
3148
2891
2645
2410
2186
1973
1771
1580
1399

GPM
184.2
173.6
163.2
153.2
143.4
134.0
124.9
116.2
107.7
99.6
91.8
91.8
84.3
77.1
70.3
63.7
57.5
51.6
46.1
40.8
84

150 RPM

BPD
9476
8926
8394
7877
7377
6894
6426
5976
5541
5123
4722
4722
4336
3968
3615
3279
2959
2656
2369
2099

GPM
276.4
260.3
244.8
229.7
215.2
201.1
187.4
174.3
161.6
149.4
137.7
137.7
126.5
115.7
105.4
95.6
86.3
77.5
69.1
61.2
126

100 RPM
150 RPM
Max.
Press.
kPa M3/Hr L/Sec. M3/Hr L/Sec.
4860
41.8
11.6
62.8
17.4
5159
39.4
10.9
59.1
16.4
5487
37.1
10.3
55.6
15.4
5846
34.8
9.7
52.2
14.5
6243
32.6
9.0
48.9
13.6
6681
30.4
8.5
45.7
12.7
7166
28.4
7.9
42.6
11.8
7707
26.4
7.3
39.6
11.0
8311
24.5
6.8
36.7
10.2
8989
22.6
6.3
33.9
9.4
9791
20.8
5.8
31.3
8.7
9791
20.8
5.8
31.3
8.7
10621 19.1
5.3
28.7
8.0
11608 17.5
4.9
26.3
7.3
12740 16.0
4.4
23.9
6.7
14046 14.5
4.0
21.7
6.0
8532 396.7 13.1 595.0
19.6
1141 195.2 356.0 292.8 534.0
0
20.9 174.1 31.3
261.2
21925
9.3
2.6
13.9
3.9
63
94

200 RPM

BPD
GPM
12634
368.5
11902
347.1
11191
326.4
10503
306.3
9836
286.9
9191
268.1
8568
249.9
7967
232.4
7388
215.5
6831
199.2
6295
183.6
6295
183.6
5782
168.6
5290
154.3
4820
140.6
4372
127.5
3946
115.1
3541
103.3
3159
92.1
2798
81.6
168

200 RPM

M3/Hr
83.7
78.8
74.1
69.6
65.1
60.9
56.8
52.8
48.9
45.2
41.7
41.7
38.3
35.0
31.9
29.0
793.4
390.4
41.8
18.5

L/Sec.
23.2
21.9
20.6
19.3
18.1
16.9
15.8
14.7
13.6
12.6
11.6
11.6
10.6
9.7
8.9
8.0
26.1
712.1
348.2
5.1
126

250 RPM

BPD
15792
14877
13989
13128
12295
11489
10710
9959
9235
8538
7869
7869
7227
6612
6025
5465
4932
4427
3948
3498

GPM
460.6
433.9
408.0
382.9
358.6
335.1
312.4
290.5
269.3
249.0
229.5
229.5
210.8
192.8
175.7
159.4
143.8
129.1
115.1
102.0
210

250 RPM

300 RPM

BPD
18951
17852
16787
15754
14754
13787
12852
11951
11082
10246
9443
9443
8672
7935
7230
6558
5918
5312
4738
4197

GPM
552.7
520.7
489.6
459.5
430.3
402.1
374.8
348.6
323.2
298.8
275.4
275.4
252.9
231.4
210.9
191.2
172.6
154.9
138.2
122.4
250

300 RPM

320 RPM

BPD
20214
19042
17906
16804
15738
14706
13709
12748
11821
10929
10072
10072
9250
8464
7712
6995
6313
5666
5054
4477

GPM
589.6
555.4
522.2
490.1
459.0
428.9
399.8
371.8
344.8
318.7
293.8
293.8
269.8
246.8
224.9
204.0
184.1
165.2
147.4
130.6
267

360 RPM
Max.
Press.
PSI
625.0
660.0
705.0
750.0
800.0
850.0
920.0
980.0
1060.0
1150.0
1250.0
1250.0
1360.0
1480.0
1630.0
1800.0
1980.0
2220.0
2480.0
2800.0

320 RPM

Max.
Press.
M3/Hr L/Sec. M3/Hr L/Sec. M3/Hr L/Sec. kPa
104.6
29.1
125.5
34.9
133.9
37.2
4309
98.5
27.4
118.2
32.8
126.1
35.0
4551
92.7
25.7
111.2
30.9
118.6
32.9
4861
87.0
24.2
104.3
29.0
111.3
30.9
5171
81.4
22.6
97.7
27.1
104.2
29.0
5516
76.1
21.1
91.3
25.4
97.4
27.1
5861
70.9
19.7
85.1
23.6
90.8
25.2
6343
66.0
18.3
79.2
22.0
84.4
23.5
6757
61.2
17.0
73.4
20.4
78.3
21.8
7308
56.6
15.7
67.9
18.9
72.4
20.1
7929
52.1
14.5
62.5
17.4
66.7
18.5
8618
52.1
14.5
62.5
17.4
66.7
18.5
8618
47.9
13.3
57.4
16.0
61.3
17.0
9377
43.8
12.2
52.6
14.6
56.1
15.6
10204
39.9
11.1
47.9
13.3
51.1
14.2
11238
36.2
10.1
43.4
12.1
46.3
12.9
12411
991.7
32.7 1190.1
39.2 1269.4
41.8
13652
488.0
890.1 585.6 1068.1 624.6 1139.3 15306
52.2
435.3
62.7
522.3
66.9
557.1 17099
23.2
6.4
27.8
7.7
29.7
8.2
19305
157
186
199

BPD
22741
21423
20144
18905
17705
16544
15423
14341
13298
12295
11331
11331
10407
9521
8676
7869
7102
6374
5686
5036

GPM
663.3
624.8
587.5
551.4
516.4
482.5
449.8
418.3
387.9
358.6
330.5
330.5
303.5
277.7
253.0
229.5
207.1
185.9
165.8
146.9
267

360 RPM

M3/Hr L/Sec.
150.6
41.8
141.9
39.4
133.4
37.1
125.2
34.8
117.3
32.6
109.6
30.4
102.2
28.4
95.0
26.4
88.1
24.5
81.4
22.6
75.1
20.8
75.1
20.8
68.9
19.1
63.1
17.5
57.5
16.0
52.1
14.5
47.0
13.1
42.2
11.7
37.7
10.5
33.4
9.3
199

Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on 90% Mechanical Efficiency. Not all plunger sizes are shown. Contact National-Oilwell for
additional information.
The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own
evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that
stipulated in National Oilwell Standard Terms and Conditions of Sale.

Authorized Distributor:

www.natoil.com / customer.service@natoil.com
10000 Richmond, Houston, Texas 77042
(713)346-7500 (phone) (713)346-7366 (fax)

300Q-5 Quintuplex Plunger Pump


18 5/16;

Specifications
3.500

4.875

DIA.

3.499

DIA.

1/4;9

4.873

11/16;
11

11/16;
5

7/8" x 7/16" KEYWAY

SUCTION AND DISCHARGE

1 1/4" x 5/8" KEYWAY

CONNECTIONS MAY BE

5/8;5

1/2;7

15

"C"

41
1/4;

70
1/2;

15

1/2;7

20
5/8;

38
1/8;

MADE AT EITHER END

1 3/8" DIA. HOLE THRU


4 PLACES, AS SHOWN
1 1/4" x 5/8" KEYWAY
4.875

DIA.

4.873

SHAFT EXTENSION
FOR DIRECT DRIVE

"D"
16 3/4;

36 1/2;

"A"

CENTERLINE

2
1/4;

DISCHARGE

10
1/2;

13
1/4;

"F"

1/2;6

32
1/4;

1 1/2 " STD. PIPE TAP


CRADLE DRAIN, BOTH SIDES

CENTERLINE
"B"

SUCTION

1" STD. PIPE TAP

1 1/2 " STD. PIPE TAP

7
3/4;

POWER END OIL DRAIN

MUD TRAP DRAIN

Pump Size
maximum plunger size x stroke length, in.(mm):
4 x 5 (102 x 127)
Rated bhp at 400 rpm (kw): 300 (224)
Rated plunger load, pounds(Kg): 10,700(4853.5)
Maximum discharge pressure: psi(kPa)
L model: 1650 (11,375)
M model: 3000 (20,682)
H model: 5000 (34,470)
Crankshaft extension: in.(mm)
Diameter: 4.875 (123.8)
Length long side: 11 11/16 (297)
Length short side: 5 5/8 (143)
Keyway (width x depth):
1 1/4 x 5/8 (32 x 16)
Maximum recommended sheave
in.(mm): 58 (1473)
Minimum recommended sheave
in.(mm): 36 (914)
For larger sizes: Contact Customer Service
Pinion shaft extension,
if gear reducer is supplied, in.(mm)
For belt or chain drive:
Contact Customer Service
For direct drive: Diameter: 3.5 (88.9)
Length: 5 11/16 (145)
Keyway (width x depth):
7/8 x 7/16 ((22.2 x 11.1)
Accessory gear reduction unit:
2.27:1, 2.89:1, 3.25:1, 3.36:1, 3.69:1,
4.38:1, 4.84:1, 5.63:1
Oil Capacity, gallons (L)
Crankcase: 12 (45.5)
Gear Reducer-varies with ratio:
3.5 to 6.5 (13.2 to 24.6)
Weight, pump only on
wood shipping skids, pounds (Kg)
L: 7000 (3175)
M: 6750 (3062)
H: 6840 (3103)
Gear reducer, approximate, pounds (Kg):
1100 (499)

2" STD. PIPE TAP


CRADLE DRAIN

19 3/4;
4
1/2;

40 3/4;
"E"

Pump Model
300Q-5L
300Q-5M
300Q-5H

Flange Connections
Discharge Connection Sizes Suction Connection Sizes
4 (101.6) API 2000 RJ
8 (203.2) ANSI 150 FF
3 (76.2) NSD 5000 RJ
6 (152.4) NSD 600 RJ
2 (50.8) ANSI 2500 RJ
6 (152.4) NSD 600 RJ

A
6 1/4
4 1/2
4 1/2

Dimensions in inches (mm)


B
C
D
E
9 1/8
43 1/4
49
68
6 1/2
41 1/2
48 5/8
65
6 1/2
41 1/2
48 5/8
65 1/8

F
25 1/8
25 7/16
25 5/8

300Q-5 Quintuplex Plunger Pump


Performance Data
PUMP

300Q-5L

300Q-5M

300Q-5H

PUMP

300Q-5L

300Q-5M

300Q-5H

English Units
Plunger
Plunger
BPD
Dia.
Area
per
In.
Sq. In.
RPM
4.000
12.5664
46.6284
3.750
11.0447
40.9820
3.500
9.6211
35.6999
3.250
8.2958
30.7820
3.000
7.0686
26.2285
2.750
5.9396
22.0392
2.750
5.9396
22.0392
2.500
4.9087
18.2142
2.375
4.4301
16.4383
2.250
3.9761
14.7535
2.125
3.5466
13.1598
2.000
3.1416
11.6571
2.000
3.1416
11.6571
1.875
2.7612
10.2455
1.750
2.4053
8.9250
1.625
2.0739
7.6955
1.500
1.7671
6.5571
Brake Horsepower Required

GPM
per
RPM
1.3600
1.1953
1.0412
0.8978
0.7650
0.6428
0.6428
0.5312
0.4795
0.4303
0.3838
0.3400
0.3400
0.2988
0.2603
0.2245
0.1912

Metric Units
Plunger
Plunger
Dia.
Area
mm
cm2
102
81.073
95
71.256
89
62.072
83
53.521
76
45.604
70
38.320
70
38.320
64
31.669
60
28.581
57
25.652
54
22.881
51
20.268
51
20.268
48
17.814
44
15.518
41
13.380
38
11.401
Kilowatts Required

L/Sec.
per
RPM
0.0858
0.0754
0.0657
0.0566
0.0483
0.0406
0.0406
0.0335
0.0302
0.0271
0.0242
0.0215
0.0215
0.0189
0.0164
0.0142
0.0121

M3/Hr
per
RPM
0.3089
0.2715
0.2365
0.2039
0.1737
0.1460
0.1460
0.1206
0.1089
0.0977
0.0872
0.0772
0.0772
0.0679
0.0591
0.0510
0.0434

100 RPM
Max.
Press.
PSI
851
969
1112
1290
1514
1650
1801
2180
2415
2691
3000
3000
3406
3875
4449
5000
5000

BPD
4663
4099
3570
3079
2623
2204
2204
1822
1644
1476
1316
1166
1166
1025
893
770
656

GPM
136.0
119.5
104.1
89.8
76.5
64.3
64.3
53.1
47.9
43.0
38.4
34.0
34.0
29.9
26.0
22.4
19.1
76

200 RPM

BPD
9326
8197
7140
6157
5246
4408
4408
3643
3288
2951
2632
2332
2332
2050
1785
1540
1312

250 RPM

GPM
272.0
239.1
208.2
179.6
153.0
128.6
128.6
106.2
95.9
86.1
76.8
68.0
68.0
59.8
52.1
44.9
38.2
151

BPD
11658
10246
8925
7696
6558
5510
5510
4554
4110
3689
3290
2915
2915
2562
2232
1924
1640

100 RPM
200 RPM
Max.
Press.
kPa M3/Hr L/Sec. M3/Hr L/Sec.
5871
30.9
8.6
61.8
17.2
6680
27.1
7.5
54.3
15.1
7668
23.6
6.6
47.3
13.1
8893
20.4
5.7
40.8
11.3
10437 17.4
4.8
34.7
9.7
11376 14.6
4.1
29.2
8.1
12421 14.6
4.1
29.2
8.1
15029 12.1
3.4
24.1
6.7
16653 10.9
3.0
21.8
6.0
18555
9.8
2.7
19.5
5.4
20684
8.7
2.4
17.4
4.8
20684
7.7
2.1
15.4
4.3
23483
7.7
2.1
15.4
4.3
26719
6.8
1.9
13.6
3.8
30672
5.9
1.6
11.8
3.3
34474
5.1
1.4
10.2
2.8
34474
4.3
1.2
8.7
2.4
57
113

GPM
340.0
298.8
260.3
224.5
191.2
160.7
160.7
132.8
119.9
107.6
96.0
85.0
85.0
74.7
65.1
56.1
47.8
188

250 RPM

M3/Hr
77.2
67.9
59.1
51.0
43.4
36.5
36.5
30.2
27.2
24.4
21.8
19.3
19.3
17.0
14.8
12.7
10.9

L/Sec.
21.5
18.9
16.4
14.2
12.1
10.1
10.1
8.4
7.6
6.8
6.1
5.4
5.4
4.7
4.1
3.5
3.0
140

300 RPM

BPD
13989
12295
10710
9235
7869
6612
6612
5465
4932
4427
3948
3498
3498
3074
2678
2309
1968

GPM
408.0
358.6
312.4
269.3
229.5
192.8
192.8
159.4
143.8
129.1
115.1
102.0
102.0
89.6
78.1
67.3
57.4
225

300 RPM

M3/Hr
92.7
81.4
70.9
61.2
52.1
43.8
43.8
36.2
32.7
29.3
26.2
23.2
23.2
20.4
17.7
15.3
13.0

350 RPM

400 RPM

BPD
GPM
16320
476.0
14344
418.4
12495
364.4
10774
314.2
9180
267.7
7714
225.0
7714
225.0
6375
185.9
5754
167.8
5164
150.6
4606
134.3
4080
119.0
4080
119.0
3586
104.6
3124
91.1
2694
78.6
2295
66.9
263

BPD
GPM
18652 544.0
16393 478.1
14280 416.5
12313 359.1
10492 306.0
8816
257.1
8816
257.1
7286
212.5
6576
191.8
5902
172.1
5264
153.5
4663
136.0
4663
136.0
4099
119.5
3570
104.1
3079
89.8
2623
76.5
300

350 RPM

400 RPM

L/Sec. M3/Hr L/Sec. M3/Hr L/Sec.


25.7
108.1
30.0
123.5
34.3
22.6
95.0
26.4
108.6
30.2
19.7
82.8
23.0
94.6
26.3
17.0
71.4
19.8
81.6
22.7
14.5
60.8
16.9
69.5
19.3
12.2
51.1
14.2
58.4
16.2
12.2
51.1
14.2
58.4
16.2
10.1
42.2
11.7
48.3
13.4
9.1
38.1
10.6
43.6
12.1
8.1
34.2
9.5
39.1
10.9
7.3
30.5
8.5
34.9
9.7
6.4
27.0
7.5
30.9
8.6
6.4
27.0
7.5
30.9
8.6
5.7
23.8
6.6
27.1
7.5
4.9
20.7
5.7
23.6
6.6
4.2
17.8
5.0
20.4
5.7
3.6
15.2
4.2
17.4
4.8
168
196
224

Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on 90% Mechanical Efficiency. For Operations below 200 RPM, an auxiliary lubrication
system is required. Not all plunger sizes are shown. Contact National-Oilwell for additional information. Spherical Valves must be installed when the pump is fitted with 4.0 (102mm) plungers.
The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own
evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that
stipulated in National Oilwell Standard Terms and Conditions of Sale.

Authorized Distributor:

www.natoil.com / customer.service@natoil.com
10000 Richmond, Houston, Texas 77042
(713)346-7500 (phone) (713)346-7366 (fax)

308T-7 Triplex Plunger Pump


INTERNAL LUBE PUMP

Specifications

PRESSURE GAUGE

24.00

13.00
TYP

D
SUCTION

C
DISCHARGE
13.00
TYP

32.00

1.12
TYP
4 PLACES

1.250 x .625 KEY WAY


10.125 LONG

5.500
5.499

DISCHARGE
CONNECTION
ROTATION
DIRECTION

G
1.50

29.25

13.75

6.50

Pump Size:
maximum plunger size x stroke length, in.(mm)
5.750 x 7.125 (146.05 x 180.98)
Rated BPH (kW) at 265 RPM: 308 (230)
Rated plunger load, pounds (kg): 19400(8800)
Maximum discharge pressure: psi (kPa)
XL model: 1220 (8410)
L model: 2169 (14952)
M model: 3600 (24821)
H model: 8000 (55158)
Crankshaft extension:
Diameter, in.(mm): 5.500 (139.7)
Length, in.(mm): 12.125 (307.98)
Keyway width x depth, in.(mm):
1-1/4 x 5/8 (31.75 x 15.875)
Maximum recommended sheave diameter,
in.(mm): 71 (1803.4)
For larger sizes: Contact Customer Service
Accessory gear reduction unit: N/A
Oil Capacity, gallons (L)
Crankcase: 19 (71.92)
Weight, pump only on
wood shipping skids, pounds (kg): 6013 (2727)
Weight varies with pump model
Standard Materials for Fluid Ends:
XL model
Cast Duplex Stainless Steel
Cast Carbon Steel
L model
Cast Duplex Stainless Steel
Cast Nickel-Aluminum-Bronze
Billet/Forged Carbon Steel
M model
Cast Duplex Stainless Steel
Cast Nickel-Aluminum-Bronze
Forged/Plate Carbon Steel
H model
Forged Stainless Steel

SUCTION
CONNECTION

15.06

38.01

Pump Model
308T-7XL
308T-7L
308T-7M
308T-7H

Flange Connections
Discharge Connection Sizes Suction Connection Sizes
4 (101.6)-600# ANSI FF
10 (254.0)-150# ANSI FF
4 (101.6)-900# ANSI FF
6 (152.4)-150# ANSI FF
2.5 (63.5)-1500# ANSI FF
4 (101.6)-300# ANSI FF
2 (50.8)-2500# ANSI RTJ
4 (101.6)-300# ANSI RF

A
10
8 1/4
6 7/8
3 7/16

B
14 3/8
14 3/8
8 3/4
12 7/16

Dimensions (Inches)
C
D
E
F
34
36
48 3/8
72
33
33
46 3/4
71
34
36
48 3/8
71
31
33
53 5/16 68 3/8

G
16 5/8
13 1/4
16 5/8
11 1/2

H
7 1/4
1
-1 1/2
2 1/4

308T-7 Triplex Plunger Pump


Performance Data
PUMP

308T-7XL
(HP360XL)

308T-7L
(HP360AL)

308T-7M
(HP360AM)

308T-7H
(HP360H)

PUMP

308T-7XL
(HP360XL)

308T-7L
(HP360AL)

308T-7M
(HP360AM)

308T-7H
(HP360H)

English Units
Plunger
Plunger
BPD
Dia.
Area
per
In.
Sq. In.
RPM
5.750
25.9672
82.3820
5.500
23.7583
75.3741
5.250
21.6475
68.6776
5.000
19.6349
62.2926
4.750
17.7205
56.2191
4.500
15.9043
50.4570
4.250
14.1862
45.0064
4.125
13.3640
42.3979
4.000
12.5664
39.8673
3.875
11.7932
37.4145
3.750
11.0447
35.0396
3.625
10.3206
32.7426
3.500
9.6211
30.5234
3.375
8.9462
28.3821
3.250
8.2958
26.3186
3.125
7.6699
24.3331
3.000
7.0686
22.4253
2.875
6.4918
20.5955
2.750
5.9396
18.8435
2.500
4.9087
15.5732
2.250
3.9761
12.6143
2.125
3.5466
11.2516
2.000
3.1416
9.9668
1.875
2.7612
8.7599
1.750
2.4053
7.6308
Brake Horsepower Required

GPM
per
RPM
2.4028
2.1984
2.0031
1.8169
1.6397
1.4717
1.3127
1.2366
1.1628
1.0913
1.0220
0.9550
0.8903
0.8278
0.7676
0.7097
0.6541
0.6007
0.5496
0.4542
0.3679
0.3282
0.2907
0.2555
0.2226

Max.
Press.
PSI
747
817
896
988
1095
1220
1368
1452
1544
1645
1757
1880
2016
2169
2339
2529
2745
2988
3266
3600
3600
5470
6175
7026
8000

Metric Units
Plunger
Plunger
Dia.
Area
mm
cm2
146
167.530
140
153.279
133
139.661
127
126.677
121
114.326
114
102.608
108
91.524
105
86.219
102
81.073
98
76.085
95
71.256
92
66.584
89
62.072
86
57.717
83
53.521
79
49.483
76
45.604
73
41.883
70
38.320
64
31.669
57
25.652
54
22.881
51
20.268
48
17.814
44
15.518
Kilowatts Required

L/Sec.
per
RPM
0.1516
0.1387
0.1264
0.1146
0.1035
0.0928
0.0828
0.0780
0.0734
0.0688
0.0645
0.0603
0.0562
0.0522
0.0484
0.0448
0.0413
0.0379
0.0347
0.0287
0.0232
0.0207
0.0183
0.0161
0.0140

100 * RPM
133 RPM
Max.
Press.
kPa M3/Hr L/Sec. M3/Hr L/Sec.
5151
54.6
15.2
72.6
20.2
5630
49.9
13.9
66.4
18.4
6179
45.5
12.6
60.5
16.8
6812
41.3
11.5
54.9
15.2
7548
37.2
10.3
49.5
13.8
8410
33.4
9.3
44.5
12.3
9429
29.8
8.3
39.6
11.0
10009 28.1
7.8
37.4
10.4
10644 26.4
7.3
35.1
9.8
11342 24.8
6.9
33.0
9.2
12111 23.2
6.4
30.9
8.6
12960 21.7
6.0
28.8
8.0
13903 20.2
5.6
26.9
7.5
14952 18.8
5.2
25.0
6.9
16124 17.4
4.8
23.2
6.4
17439 16.1
4.5
21.4
6.0
18923 14.9
4.1
19.8
5.5
20604 13.6
3.8
18.1
5.0
22520 12.5
3.5
16.6
4.6
24821 10.3
2.9
13.7
3.8
24821
8.4
2.3
11.1
3.1
37715
7.5
2.1
9.9
2.8
42577
6.6
1.8
8.8
2.4
48443
5.8
1.6
7.7
2.1
55158
5.1
1.4
6.7
1.9
87
116

M3/Hr
per
RPM
0.5457
0.4993
0.4549
0.4126
0.3724
0.3342
0.2981
0.2808
0.2641
0.2478
0.2321
0.2169
0.2022
0.1880
0.1743
0.1612
0.1485
0.1364
0.1248
0.1032
0.0836
0.0745
0.0660
0.0580
0.0505

100 * RPM

BPD
8239
7538
6868
6230
5622
5046
4501
4240
3987
3742
3504
3275
3053
2839
2632
2434
2243
2060
1885
1558
1262
1126
997
876
764

GPM
240.3
219.8
200.3
181.7
164.0
147.2
131.3
123.7
116.3
109.1
102.2
95.5
89.0
82.8
76.8
71.0
65.4
60.1
55.0
45.4
36.8
32.8
29.1
25.5
22.3
117

133 RPM

BPD
10957
10025
9135
8285
7478
6711
5986
5639
5303
4977
4661
4355
4060
3775
3501
3237
2983
2740
2507
2072
1678
1497
1326
1166
1665

GPM
319.6
292.4
266.4
241.6
218.1
195.7
174.6
164.5
154.7
145.1
135.9
127.0
118.4
110.1
102.1
94.4
87.0
79.9
73.1
60.4
48.9
43.6
38.7
34.0
29.6
155

166 RPM

BPD
13676
12513
11401
10341
9333
8376
7472
7039
6618
6211
5817
5436
5067
4712
4369
4040
3723
3419
3129
2586
2094
1868
1655
1455
1267

GPM
398.9
364.9
332.5
301.6
272.2
244.3
217.9
205.3
193.0
181.1
169.7
158.5
147.8
137.4
127.4
117.8
108.6
99.7
91.2
75.4
61.1
54.5
48.3
42.4
36.9
194

166 RPM

M3/Hr L/Sec.
90.6
25.2
82.9
23.0
75.5
21.0
68.5
19.0
61.8
17.2
55.5
15.4
49.5
13.7
46.6
13.0
43.8
12.2
41.1
11.4
38.5
10.7
36.0
10.0
33.6
9.3
31.2
8.7
28.9
8.0
26.8
7.4
24.7
6.9
22.6
6.3
20.7
5.8
17.1
4.8
13.9
3.9
12.4
3.4
11.0
3.0
9.6
2.7
8.4
2.3
145

199 RPM

BPD
16395
15000
13667
12397
11188
10041
8957
8438
7934
7446
6973
6516
6075
5649
5238
4843
4463
4099
3750
3100
2511
2240
1984
1744
1519

GPM
478.2
437.5
398.6
361.6
326.3
292.9
261.2
246.1
231.4
217.2
203.4
190.0
177.2
164.7
152.8
141.2
130.2
119.5
109.4
90.4
73.2
65.3
57.8
50.8
44.3
232

199 RPM

M3/Hr
108.6
99.4
90.5
82.1
74.1
66.5
59.3
55.9
52.6
49.3
46.2
43.2
40.2
37.4
34.7
32.1
29.6
27.1
24.8
20.5
16.6
14.8
13.1
11.5
10.1

232 RPM

BPD
19113
17487
15934
14452
13043
11707
10442
9837
9250
8681
8130
7597
7082
6585
6106
5646
5203
4779
4372
3613
2927
2611
2313
2033
1771

GPM
557.5
510.0
464.7
421.5
380.4
341.4
304.5
286.9
269.8
253.2
237.1
221.6
206.5
192.1
178.1
164.7
151.7
139.4
127.5
105.4
85.4
76.1
67.4
59.3
51.6
270

232 RPM

265 RPM

BPD
GPM
21832 636.7
19975 582.6
18200 530.8
16508 481.5
14899 434.5
13372 390.0
11927 347.9
11236 327.7
10565 308.1
9915
289.2
9286
270.8
8677
253.1
8089
235.9
7522
219.4
6975
203.4
6449
188.1
5943
173.3
5458
159.2
4994
145.6
4127
120.4
3343
97.5
2982
87.0
2642
77.0
2322
67.7
2023
59.0
308

265 RPM

L/Sec. M3/Hr L/Sec. M3/Hr L/Sec.


30.2
126.6
35.2
144.6
40.2
27.6
115.8
32.2
132.3
36.8
25.1
105.5
29.3
120.5
33.5
22.8
95.7
26.6
109.3
30.4
20.6
86.4
24.0
98.7
27.4
18.5
77.5
21.5
88.6
24.6
16.5
69.2
19.2
79.0
21.9
15.5
65.2
18.1
74.4
20.7
14.6
61.3
17.0
70.0
19.4
13.7
57.5
16.0
65.7
18.2
12.8
53.8
15.0
61.5
17.1
12.0
50.3
14.0
57.5
16.0
11.2
46.9
13.0
53.6
14.9
10.4
43.6
12.1
49.8
13.8
9.6
40.4
11.2
46.2
12.8
8.9
37.4
10.4
42.7
11.9
8.2
34.5
9.6
39.4
10.9
7.5
31.6
8.8
36.2
10.0
6.9
29.0
8.0
33.1
9.2
5.7
23.9
6.6
27.3
7.6
4.6
19.4
5.4
22.1
6.2
4.1
17.3
4.8
19.7
5.5
3.6
15.3
4.3
17.5
4.9
3.2
13.5
3.7
15.4
4.3
2.8
11.7
3.3
13.4
3.7
173
201
230

Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on 90% Mechanical Efficiency. *Operation below 150 RPM
requires an optional externally-mounted electric motor-driven auxillary lubrication system.
The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own
evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that
stipulated in National Oilwell Standard Terms and Conditions of Sale.

Authorized Distributor:

www.natoil.com / customer.service@natoil.com
10000 Richmond, Houston, Texas 77042
(713)346-7500 (phone) (713)346-7366 (fax)

350Q-5 Quintuplex Plunger Pump


EXTERNAL LUBE PUMP

Specifications

1.00
TYP
4 PLACES

38.25

C/2

C/2

45.75
TYP
D

22.88
TYP
D/2

D/2

27.61

ROTATI0N DIRECTION
10.16

1.250 x .625 KEYWAY


9.000 LONG

4.937
4.936

350Q-5H ONLY

13.66

G
A

12.00

1.25

11.75

16.38

44.50

Pump Size:
maximum plunger size x stroke length, in.(mm):
4.000 x 5.000 (101.6 x 127)
Rated BHP (kW) at 360 RPM: 350 (261)
Rated plunger load, pounds (kg): 13850(6282)
Maximum discharge pressure: psi (kPa)
L model: 1670 (11511)
M model: 3483 (24017)
H model: 6000 (41369)
Crankshaft extension:
Diameter, in.(mm): 4.937 (125.4)
Length, in.(mm): 10.125 (257.18)
Keyway width x depth, in.(mm):
1 1/4 x 5/8 (31.75 x 15.875)
Maximum recommended sheave diameter,
in.(mm): 63 (1346.2)
For larger sizes: Contact Customer Service
Oil Capacity, gallons (L)
Crankcase: 25.0 (94.63)
Gear Reducer-varies with ratio: N/A
Weight, pump only on
wood shipping skids, pounds (kg): 9000 (4082)
Standard Materials For Fluid End Bodies:
L & M modelS
Cast Nickel-Aluminum-Bronze
Cast Duplex Stainless Steel
Forged/Plate Carbon Steel
H model
Forged Carbon Steel
Forged Nickel-Aluminum-Bronze

59.38
F

Pump Model
350Q-5L
350Q-5M
350Q-5H

Flange Connections
Discharge Connection Sizes Suction Connection Sizes
4 (101.6)-2000# API
8 (203.2)-300# ANSI FF
3 (76.02)-1500# ANSI FF
6 (152.4)-300# ANSI FF
2 (50.8)-2500# ANSI RF
4 (101.6)-300# ANSI RF

A
6 1/2
6
10 3/8

B
9 1/2
8
0

Dimensions (Inches)
C
D
E
45
52
53 7/8
45 1/2 51 1/2 53 1/2
52
49 3/4
52

F
77 3/4
76 1/8
80 3/4

G
12 1/2
12 5/8
15

H
5
2 1/4
7

350Q-5 Quintuplex Plunger Pump


Performance Data
PUMP

350Q-5L
(Q350-4)

350Q-5M
(Q350-3)

350Q-5H
(Q350-2)

PUMP

350Q-5L
(Q350-4)

350Q-5M
(Q350-3)

350Q-5H
(Q350-2)

English Units
Plunger
Plunger
BPD
Dia.
Area
per
In.
Sq. In.
RPM
4.000
12.5664
46.6284
3.875
11.7932
43.7597
3.750
11.0447
40.9820
3.625
10.3206
38.2954
3.500
9.6211
35.6999
3.375
8.9462
33.1954
3.250
8.2958
30.7820
3.250
8.2958
30.7820
3.125
7.6699
28.4597
3.000
7.0686
26.2285
2.875
6.4918
24.0883
2.750
5.9396
22.0392
2.625
5.4119
20.0812
2.500
4.9087
18.2142
2.375
4.4301
16.4383
2.250
3.9761
14.7535
2.250
3.9761
14.7535
2.125
3.5466
13.1598
2.000
3.1416
11.6571
1.875
2.7612
10.2455
1.750
2.4053
8.9250
1.625
2.0739
7.6955
1.500
1.7671
6.5571
Brake Horsepower Required

GPM
per
RPM
1.3600
1.2763
1.1953
1.1169
1.0412
0.9682
0.8978
0.8978
0.8301
0.7650
0.7026
0.6428
0.5857
0.5312
0.4795
0.4303
0.4303
0.3838
0.3400
0.2988
0.2603
0.2245
0.1912

Metric Units
Plunger
Plunger
Dia.
Area
mm
cm2
102
81.073
98
76.085
95
71.256
92
66.584
89
62.072
86
57.717
83
53.521
83
53.521
79
49.483
76
45.604
73
41.883
70
38.320
67
34.915
64
31.669
60
28.581
57
25.652
57
25.652
54
22.881
51
20.268
48
17.814
44
15.518
41
13.380
38
11.401
Kilowatts Required

L/Sec.
per
RPM
0.0858
0.0805
0.0754
0.0705
0.0657
0.0611
0.0566
0.0566
0.0524
0.0483
0.0443
0.0406
0.0370
0.0335
0.0302
0.0271
0.0271
0.0242
0.0215
0.0189
0.0164
0.0142
0.0121

M3/Hr
per
RPM
0.3089
0.2899
0.2715
0.2537
0.2365
0.2199
0.2039
0.2039
0.1885
0.1737
0.1596
0.1460
0.1330
0.1206
0.1089
0.0977
0.0977
0.0872
0.0772
0.0679
0.0591
0.0510
0.0434

100 RPM
Max.
Press.
PSI
1102
1174
1254
1342
1440
1548
1670
1670
1806
1959
2133
2332
2559
2822
3126
3483
3483
3905
4409
5016
5758
6000
6000

BPD
4663
4376
4099
3830
3570
3320
3079
3079
2846
2623
2409
2204
2009
1822
1644
1476
1476
1316
1166
1025
893
770
656

GPM
136.0
127.6
119.5
111.7
104.1
96.8
89.8
89.8
83.0
76.5
70.3
64.3
58.6
53.1
47.9
43.0
43.0
38.4
34.0
29.9
26.0
22.4
19.1
98

150 RPM

BPD
6995
6564
6148
5745
5355
4980
4618
4618
4269
3935
3614
3306
3013
2733
2466
2214
2214
1974
1749
1537
1339
1155
984

GPM
204.0
191.4
179.3
167.5
156.2
145.2
134.7
134.7
124.5
114.7
105.4
96.4
87.9
79.7
71.9
64.5
64.5
57.6
51.0
44.8
39.0
33.7
28.7
146

100 RPM
150 RPM
Max.
Press.
kPa M3/Hr L/Sec. M3/Hr L/Sec.
7599
30.9
8.6
46.3
12.9
8097
29.0
8.1
43.5
12.1
8646
27.1
7.5
40.7
11.3
9253
25.4
7.0
38.0
10.6
9925
23.6
6.6
35.5
9.9
10674 22.0
6.1
33.0
9.2
11511 20.4
5.7
30.6
8.5
11511 20.4
5.7
30.6
8.5
12450 18.9
5.2
28.3
7.9
13510 17.4
4.8
26.1
7.2
14710 16.0
4.4
23.9
6.6
16077 14.6
4.1
21.9
6.1
17645 13.3
3.7
20.0
5.5
19454 12.1
3.4
18.1
5.0
21555 10.9
3.0
16.3
4.5
24017
9.8
2.7
14.7
4.1
24017
9.8
2.7
14.7
4.1
26926
8.7
2.4
13.1
3.6
30396
7.7
2.1
11.6
3.2
34584
6.8
1.9
10.2
2.8
39701
5.9
1.6
8.9
2.5
41369
5.1
1.4
7.6
2.1
41369
4.3
1.2
6.5
1.8
73
109

200 RPM

BPD
9326
8752
8197
7660
7140
6640
6157
6157
5692
5246
4818
4408
4017
3643
3288
2951
2951
2632
2332
2050
1785
1540
1312

GPM
272.0
255.3
239.1
223.4
208.2
193.6
179.6
179.6
166.0
153.0
140.5
128.6
117.1
106.2
95.9
86.1
86.1
76.8
68.0
59.8
52.1
44.9
38.2

250 RPM

BPD
11658
10940
10246
9574
8925
8299
7696
7696
7115
6558
6023
5510
5021
4554
4110
3689
3689
3290
2915
2562
2232
1924
1640

195

200 RPM

M3/Hr
61.8
58.0
54.3
50.7
47.3
44.0
40.8
40.8
37.7
34.7
31.9
29.2
26.6
24.1
21.8
19.5
19.5
17.4
15.4
13.6
11.8
10.2
8.7

L/Sec.
17.2
16.1
15.1
14.1
13.1
12.2
11.3
11.3
10.5
9.7
8.9
8.1
7.4
6.7
6.0
5.4
5.4
4.8
4.3
3.8
3.3
2.8
2.4
145

GPM
340.0
319.1
298.8
279.2
260.3
242.1
224.5
224.5
207.5
191.2
175.6
160.7
146.4
132.8
119.9
107.6
107.6
96.0
85.0
74.7
65.1
56.1
47.8
243

250 RPM

M3/Hr
77.2
72.5
67.9
63.4
59.1
55.0
51.0
51.0
47.1
43.4
39.9
36.5
33.3
30.2
27.2
24.4
24.4
21.8
19.3
17.0
14.8
12.7
10.9

300 RPM

BPD
13989
13128
12295
11489
10710
9959
9235
9235
8538
7869
7227
6612
6025
5465
4932
4427
4427
3948
3498
3074
2678
2309
1968

GPM
408.0
382.9
358.6
335.1
312.4
290.5
269.3
269.3
249.0
229.5
210.8
192.8
175.7
159.4
143.8
129.1
129.1
115.1
102.0
89.6
78.1
67.3
57.4
292

300 RPM

360 RPM

BPD
16787
15754
14754
13787
12852
11951
11082
11082
10246
9443
8672
7935
7230
6558
5918
5312
5312
4738
4197
3689
3213
2771
2361

GPM
489.6
459.5
430.3
402.1
374.8
348.6
323.2
323.2
298.8
275.4
252.9
231.4
210.9
191.2
172.6
154.9
154.9
138.2
122.4
107.6
93.7
80.8
68.8
350

360 RPM

L/Sec. M3/Hr L/Sec. M3/Hr L/Sec.


21.5
92.7
25.7
111.2
30.9
20.1
87.0
24.2
104.3
29.0
18.9
81.4
22.6
97.7
27.1
17.6
76.1
21.1
91.3
25.4
16.4
70.9
19.7
85.1
23.6
15.3
66.0
18.3
79.2
22.0
14.2
61.2
17.0
73.4
20.4
14.2
61.2
17.0
73.4
20.4
13.1
56.6
15.7
67.9
18.9
12.1
52.1
14.5
62.5
17.4
11.1
47.9
13.3
57.4
16.0
10.1
43.8
12.2
52.6
14.6
9.2
39.9
11.1
47.9
13.3
8.4
36.2
10.1
43.4
12.1
7.6
32.7
9.1
39.2
10.9
6.8
29.3
8.1
35.2
9.8
6.8
29.3
8.1
35.2
9.8
6.1
26.2
7.3
31.4
8.7
5.4
23.2
6.4
27.8
7.7
4.7
20.4
5.7
24.4
6.8
4.1
17.7
4.9
21.3
5.9
3.5
15.3
4.2
18.4
5.1
3.0
13.0
3.6
15.6
4.3
181
217
261

Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on 90% Mechanical Efficiency.
The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own
evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that
stipulated in National Oilwell Standard Terms and Conditions of Sale.

Authorized Distributor:

www.natoil.com / customer.service@natoil.com
10000 Richmond, Houston, Texas 77042
(713)346-7500 (phone) (713)346-7366 (fax)

430T-7 Triplex Plunger Pump


1 1/2" x 3/4" KEYWAY

5.998
DIA.
6.000

Specifications
SUCTION & DISCHARGE CONNECTIONS
MAY BE MADE AT EITHER END

10 1/4" (USABLE SHAFT EXT.)

45 7/8

"C"

39 27/32

"C/2"

20 3/4

22 15/16

14 3/8

"C"

79 11/16

14 3/8

20 3/4

6 1/2

4 7/8

8
1 1/2 " DIA. HOLE THRU

6.000
DIA.
5.998

4 PLACES, AS SHOWN

10 1/4" (USABLE SHAFT EXT.)

"H" FLUID END ONLY


1 1/2" x 3/4" KEYWAY
DISCHARGE
CENTERLINE

28 13/16

"A"

2 1/4

"B"
8 1/2

13 5/8

1 1/4

15 1/2

1 1/2 " NPT (1 EACH SIDE)

15 1/8

SUCTION
CENTERLINE

Pump Size
maximum plunger size x stroke length, in.(mm):
5 x 7 (127 x 178)
Rated bhp at 300 rpm (kw): 430 (320)
Rated plunger load, pounds(Kg): 24500(6738)
Maximum discharge pressure: psi (kPa)
L model: 1550 (10,687)
M model: 3150 (21,719)
H model: 5000 (34,470)
Crankshaft extension: in.(mm)
Diameter: 6 (152.4)
Length long side: 10 1/4 (260.4)
Length short side: 10 1/4 (260.4)
Keyway (width x depth):
1 1/2 x 3/4 (38.1 x 19.0)
Maximum recommended sheave
in.(mm): 58 (1473)
Minimum recommended sheave
in.(mm): 36 (914)
For larger sizes: Contact Customer Service
Accessory gear reduction unit ratio: N/A
Oil Capacity, gallons (L)
Crankcase: 22 (83.6)
Weight, pump only on
wood shipping skids, pounds (Kg):
10,500 (4763)

51 5/8
12 1/2
61 7/8

2" NPT (CRADLE DRAIN)

16 7/8

"D"
"E"

1" NPT (POWER END OIL DRAIN)

Pump Model
430T-5L
430T-5M
430T-5H

Flange Connections
Discharge Connection Sizes Suction Connection Sizes
A
6 (152.4) API 2000 RJ
10 (254) ANSI 150 FF
10 1/4
4 (101.6) ANSI 1500 RJ
6 (152.4) ANSI 300 FF
5 1/4
3 (76.2) ANSI 2500 RJ
6 (152.40) ANSI 300 FF
5 1/4

Dimensions in inches (mm)


B
C
D
E
10 3/4 47 3/4
65 3/8
90 1/4
8 3/4
43
64 3/8
87 3/4
8 3/4
40 1/8
64 7/8
100 1/4

430T-7 Triplex Plunger Pump


Performance Data
PUMP

430T-7L

430T-7M

430T-7H

PUMP

430T-7L

430T-7M

430T-7H

English Units
Plunger
Plunger
BPD
Dia.
Area
per
In.
Sq. In.
RPM
5.000
19.6349
61.1998
4.750
17.7205
55.2328
4.500
15.9043
49.5718
4.250
14.1862
44.2168
4.000
12.5664
39.1679
3.750
11.0447
34.4249
3.500
9.6211
29.9879
3.250
8.2958
25.8569
3.000
7.0686
22.0319
3.000
7.0686
22.0319
2.750
5.9396
18.5129
2.500
4.9087
15.2999
2.375
4.4301
13.8082
Brake Horsepower Required

GPM
per
RPM
1.7850
1.6110
1.4458
1.2897
1.1424
1.0041
0.8746
0.7542
0.6426
0.6426
0.5400
0.4462
0.4027

Metric Units
Plunger
Plunger
Dia.
Area
mm
cm2
127
126.677
121
114.326
114
102.608
108
91.524
102
81.073
95
71.256
89
62.072
83
53.521
76
45.604
76
45.604
70
38.320
64
31.669
60
28.581
Kilowatts Required

L/Sec.
per
RPM
0.1126
0.1016
0.0912
0.0814
0.0721
0.0633
0.0552
0.0476
0.0405
0.0405
0.0341
0.0282
0.0254

M3/Hr
per
RPM
0.4054
0.3658
0.3284
0.2929
0.2594
0.2280
0.1986
0.1713
0.1459
0.1459
0.1226
0.1013
0.0915

100 RPM
Max.
Press.
PSI
1248
1383
1540
1550
1550
2218
2546
2953
3150
3466
4125
4991
5000

BPD
6120
5524
4958
4422
3917
3443
2999
2586
2204
2204
1852
1530
1381

GPM
178.5
161.1
144.6
129.0
114.2
100.4
87.5
75.4
64.3
64.3
54.0
44.6
40.3
145

150 RPM

BPD
9180
8285
7436
6633
5876
5164
4499
3879
3305
3305
2777
2295
2072

200 RPM

GPM
267.7
241.6
216.9
193.4
171.4
150.6
131.2
113.1
96.4
96.4
81.0
66.9
60.4
217

BPD
12240
11047
9915
8844
7834
6885
5998
5172
4407
4407
3703
3060
2762

GPM
357.0
322.2
289.2
257.9
228.5
200.8
174.9
150.8
128.5
128.5
108.0
89.2
80.5

250 RPM

BPD
15300
13809
12393
11055
9792
8607
7497
6465
5508
5508
4629
3825
3453

289

100 RPM
150 RPM
Max.
Press.
kPa M3/Hr L/Sec. M3/Hr L/Sec.
8603
40.5
11.3
60.8
16.9
9533
36.6
10.2
54.9
15.2
10621 32.8
9.1
49.3
13.7
10687 29.3
8.1
43.9
12.2
10687 25.9
7.2
38.9
10.8
15295 22.8
6.3
34.2
9.5
17557 19.9
5.5
29.8
8.3
20363 17.1
4.8
25.7
7.1
21719 14.6
4.1
21.9
6.1
23898 14.6
4.1
21.9
6.1
28440 12.3
3.4
18.4
5.1
34413 10.1
2.8
15.2
4.2
34474
9.1
2.5
13.7
3.8
108
162

200 RPM

M3/Hr
81.1
73.2
65.7
58.6
51.9
45.6
39.7
34.3
29.2
29.2
24.5
20.3
18.3

L/Sec.
22.5
20.3
18.2
16.3
14.4
12.7
11.0
9.5
8.1
8.1
6.8
5.6
5.1
216

GPM
446.2
402.7
361.5
322.4
285.6
251.0
218.7
188.5
160.6
160.6
135.0
111.6
100.7
361

250 RPM

M3/Hr
101.3
91.5
82.1
73.2
64.9
57.0
49.7
42.8
36.5
36.5
30.7
25.3
22.9

275 RPM

BPD
16830
15190
13633
12160
10772
9467
8247
7111
6059
6059
5092
4208
3798

GPM
490.9
443.0
397.6
354.7
314.2
276.1
240.5
207.4
176.7
176.7
148.5
122.7
110.8
397

275 RPM

300 RPM

BPD
GPM
18360 535.5
16570 483.3
14872 433.8
13266 386.9
11751 342.7
10328 301.2
8997
262.4
7758
226.2
6610
192.8
6610
192.8
5554
162.0
4590
133.9
4143
120.8
433

300 RPM

L/Sec. M3/Hr L/Sec. M3/Hr L/Sec.


28.2
111.5
31.0
121.6
33.8
25.4
100.6
27.9
109.8
30.5
22.8
90.3
25.1
98.5
27.4
20.3
80.5
22.4
87.9
24.4
18.0
71.3
19.8
77.8
21.6
15.8
62.7
17.4
68.4
19.0
13.8
54.6
15.2
59.6
16.6
11.9
47.1
13.1
51.4
14.3
10.1
40.1
11.1
43.8
12.2
10.1
40.1
11.1
43.8
12.2
8.5
33.7
9.4
36.8
10.2
7.0
27.9
7.7
30.4
8.4
6.4
25.2
7.0
27.4
7.6
269
296
323

Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on 90% Mechanical Efficiency. For Operations below 100 RPM, an auxiliary lubrication
system is required. Not all plunger sizes are shown. Contact National-Oilwell for additional information.
The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own
evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that
stipulated in National Oilwell Standard Terms and Conditions of Sale.

Authorized Distributor:

www.natoil.com / customer.service@natoil.com
10000 Richmond, Houston, Texas 77042
(713)346-7500 (phone) (713)346-7366 (fax)

543Q-7 Quintuplex Plunger Pump


Specifications
24.00
TYP

C
DISCHARGE

C/2

78.25
D
SUCTION

24.00
TYP

D
D/2

43.00

5.500
5.499

1.250 X .625 KEYWAY


10.125 LONG

543Q-7H ONLY

DISCHARGE
CONNECTION

A
H
1.50

29.30
B

13.75

G
1.25
6.50

26.50
15.06

38.00

E
E

SUCTION
CONNECTION

Pump Model
543Q-7XL
543Q-7AL
543Q-7AM
543Q-7H

Flange Connections
Discharge Connection Sizes Suction Connection Sizes
4 (101.6)-600# ANSI FF
10 (254.0)-150# ANSI FF
4 (101.6)-900# ANSI FF
8 (203.2)-150# ANSI FF
3 (76.2)-1500# ANSI FF
6 (152.4)-300# ANSI FF
3 (76.2)-2500# ANSI RTJ
6 (152.4)-300# ANSI RF

A
10
8 5/8
6 7/8
4 1/2

SUCTION
CONNECTION

Pump Size:
maximum plunger size x stroke length, in.(mm):
5.750 x 7.125 (146.05 x 180.975)
Rated BHP (kW) at 280 RPM: 543 (405)
Rated plunger load, pounds (kg): 19400(8800)
Maximum discharge pressure: psi (kPa)
XL model: 1220 (8410)
L model: 2169 (14952)
M model: 3600 (24821)
H model: 8000 (55158)
Crankshaft extension:
Diameter, in.(mm): 5.500 (139.7)
Length, in.(mm): 12.125 (307.98)
Keyway width x depth, in.(mm):
1-1/4 x 5/8 (31.75 x 15.875)
Maximum recommended sheave diameter,
in.(mm): 71 (1803.4)
For larger sizes: Contact Customer Service
Oil Capacity, gallons (L)
Crankcase: 25 (94.63)
Weight, pump only on
wood shipping skids, pounds (kg): 8948 (4058.1)
Weight varies with pump model
Standard Materials for Fluid Ends:
XL model
Cast Duplex Stainless Steel
Cast Carbon Steel
L & M model
Cast Duplex Stainless Steel
Forged/Plate Carbon Steel
H model
Forged 15-5 Stainless Steel

Dimensions (Inches)
B
C
D
E
F
G
H
14 3/8
56
58 48 3/8
72
7 1/8 16 9/16
11 7/8
55
55 48 13/16
73
3 3/8
15
9
57
57 46 3/4
71
0
13 3/8
13 11/32 53 1/2 56 48 3/8 69 11/16 4 11/32 13 9/16

543Q-7 Quintuplex Plunger Pump


Performance Data
PUMP

543Q-7XL
(HP600XL)

543Q-7L
(HP600AL)

543Q-7M
(HP600AM)

543Q-7H
(HP600H)

PUMP

543Q-7XL
(HP600XL)

543Q-7L
(HP600AL)

543Q-7M
(HP600AM)

543Q-7H
(HP600H)

English Units
Plunger
Plunger
BPD
Dia.
Area
per
In.
Sq. In.
RPM
5.750
25.9672 137.3033
5.500
23.7583 125.6235
5.250
21.6475 114.4627
5.000
19.6349 103.8211
4.750
17.7205
93.6985
4.500
15.9043
84.0951
4.250
14.1862
75.0107
4.125
13.3640
70.6632
4.000
12.5664
66.4455
3.875
11.7932
62.3575
3.750
11.0447
58.3993
3.625
10.3206
54.5709
3.500
9.6211
50.8723
3.375
8.9462
47.3035
3.250
8.2958
43.8644
3.125
7.6699
40.5551
3.000
7.0686
37.3756
2.875
6.4918
34.3258
2.750
5.9396
31.4059
2.500
4.9087
25.9553
2.250
3.9761
21.0238
2.125
3.5466
18.7527
2.000
3.1416
16.6114
1.875
2.7612
14.5998
1.750
2.4053
12.7181
Brake Horsepower Required

GPM
per
RPM
4.0047
3.6640
3.3385
3.0281
2.7329
2.4528
2.1878
2.0610
1.9380
1.8188
1.7033
1.5917
1.4838
1.3797
1.2794
1.1829
1.0901
1.0012
0.9160
0.7570
0.6132
0.5470
0.4845
0.4258
0.3709

Metric Units
Plunger
Plunger
Dia.
Area
mm
cm2
146
167.530
140
153.279
133
139.661
127
126.677
121
114.326
114
102.608
108
91.524
105
86.219
102
81.073
98
76.085
95
71.256
92
66.584
89
62.072
86
57.717
83
53.521
79
49.483
76
45.604
73
41.883
70
38.320
64
31.669
57
25.652
54
22.881
51
20.268
48
17.814
44
15.518
Kilowatts Required

L/Sec.
per
RPM
0.2527
0.2312
0.2106
0.1910
0.1724
0.1547
0.1380
0.1300
0.1223
0.1147
0.1075
0.1004
0.0936
0.0870
0.0807
0.0746
0.0688
0.0632
0.0578
0.0478
0.0387
0.0345
0.0306
0.0269
0.0234

M3/Hr
per
RPM
0.9095
0.8321
0.7582
0.6877
0.6206
0.5570
0.4969
0.4681
0.4401
0.4130
0.3868
0.3615
0.3370
0.3133
0.2905
0.2686
0.2476
0.2274
0.2080
0.1719
0.1393
0.1242
0.1100
0.0967
0.0842

100 * RPM
Max.
Press.
PSI
747
817
896
988
1095
1220
1368
1452
1544
1645
1757
1880
2016
2169
2339
2529
2745
2988
3266
3600
3600
5470
6175
7026
8000

BPD GPM
13731 400.5
12563 366.4
11447 333.8
10383 302.8
9370 273.3
8410 245.3
7502 218.8
7067 206.1
6645 193.8
6236 181.9
5840 170.3
5458 159.2
5088 148.4
4731 138.0
4387 127.9
4056 118.3
3738 109.0
3433 100.1
3141
91.6
2596
75.7
2103
61.3
1876
54.7
1662
48.4
1460
42.6
1272
37.1
194

100 * RPM
Max.
Press.
kPa M3/Hr L/Sec.
5151
90.9
25.3
5630
83.2
23.1
6179
75.8
21.1
6812
68.8
19.1
7548
62.1
17.2
8410
55.7
15.5
9429
49.7
13.8
10009 46.8
13.0
10644 44.0
12.2
11342 41.3
11.5
12111 38.7
10.7
12960 36.1
10.0
13903 33.7
9.4
14952 31.3
8.7
16124 29.1
8.1
17439 26.9
7.5
18923 24.8
6.9
20604 22.7
6.3
22520 20.8
5.8
24821 17.2
4.8
24821 13.9
3.9
37715 12.4
3.5
42577 11.0
3.1
48443
9.7
2.7
55158
8.4
2.3
145

150 RPM

BPD
20596
18844
17170
15574
14055
12615
11252
10600
9967
9354
8760
8186
7631
7096
6580
6084
5607
5149
4711
3894
3154
2813
2492
2190
5214

GPM
600.7
549.6
500.8
454.2
409.9
367.9
328.2
309.2
290.7
272.8
255.5
238.7
222.6
207.0
191.9
177.4
163.5
150.2
137.4
113.6
92.0
82.0
72.7
63.9
55.6
291

150 RPM

M3/Hr L/Sec.
136.4
37.9
124.8
34.7
113.7
31.6
103.2
28.7
93.1
25.9
83.6
23.2
74.5
20.7
70.2
19.5
66.0
18.3
62.0
17.2
58.0
16.1
54.2
15.1
50.5
14.0
47.0
13.1
43.6
12.1
40.3
11.2
37.1
10.3
34.1
9.5
31.2
8.7
25.8
7.2
20.9
5.8
18.6
5.2
16.5
4.6
14.5
4.0
12.6
3.5
217

175 RPM

BPD
24029
21985
20031
18169
16398
14717
13127
12367
11628
10913
10220
9550
8903
8279
7677
7098
6541
6008
5497
4543
3680
3282
2907
2555
2226

GPM
700.8
641.2
584.2
529.9
478.3
429.2
382.9
360.7
339.1
318.3
298.1
278.5
259.7
241.4
223.9
207.0
190.8
175.2
160.3
132.5
107.3
95.7
84.8
74.5
64.9

200 RPM

BPD
27461
25125
22893
20765
18740
16820
15003
14133
13290
12472
11680
10915
10175
9461
8773
8112
7476
6866
6282
5192
4205
3751
3323
2920
2544

340

175 RPM

M3/Hr
159.2
145.6
132.7
120.3
108.6
97.5
86.9
81.9
77.0
72.3
67.7
63.3
59.0
54.8
50.8
47.0
43.3
39.8
36.4
30.1
24.4
21.7
19.3
16.9
14.7

L/Sec.
44.2
40.5
36.9
33.4
30.2
27.1
24.2
22.8
21.4
20.1
18.8
17.6
16.4
15.2
14.1
13.1
12.0
11.1
10.1
8.4
6.8
6.0
5.3
4.7
4.1
254

GPM
800.9
732.8
667.7
605.6
546.6
490.6
437.6
412.2
387.6
363.8
340.7
318.3
296.8
275.9
255.9
236.6
218.0
200.2
183.2
151.4
122.6
109.4
96.9
85.2
74.2
388

200 RPM

M3/Hr
181.9
166.4
151.6
137.5
124.1
111.4
99.4
93.6
88.0
82.6
77.4
72.3
67.4
62.7
58.1
53.7
49.5
45.5
41.6
34.4
27.9
24.8
22.0
19.3
16.8

225 RPM

BPD
30894
28266
25755
23360
21083
18922
16878
15900
14951
14031
13140
12279
11447
10644
9870
9125
8410
7724
7067
5840
4731
4220
3738
3285
2862

GPM
901.1
824.4
751.2
681.3
614.9
551.9
492.3
463.7
436.0
409.2
383.2
358.1
333.8
310.4
287.9
266.1
245.3
225.3
206.1
170.3
138.0
123.1
109.0
95.8
83.5
436

225 RPM

280 RPM

BPD
38445
35175
32050
29070
26236
23547
21003
19786
18605
17461
16352
15280
14245
13245
12283
11356
10466
9612
8794
7268
5887
5251
4652
4088
3562

GPM
1121.3
1025.9
934.8
847.9
765.2
686.8
612.6
577.1
542.6
509.3
476.9
445.7
415.5
386.3
358.2
331.2
305.2
280.3
256.5
212.0
171.7
153.1
135.7
119.2
103.9
543

280 RPM

L/Sec. M3/Hr L/Sec. M3/Hr L/Sec.


50.5
204.6
56.8
254.6
70.7
46.2
187.2
52.0
233.0
64.7
42.1
170.6
47.4
212.3
59.0
38.2
154.7
43.0
192.6
53.5
34.5
139.6
38.8
173.8
48.3
30.9
125.3
34.8
156.0
43.3
27.6
111.8
31.1
139.1
38.6
26.0
105.3
29.3
131.1
36.4
24.5
99.0
27.5
123.2
34.2
22.9
92.9
25.8
115.7
32.1
21.5
87.0
24.2
108.3
30.1
20.1
81.3
22.6
101.2
28.1
18.7
75.8
21.1
94.4
26.2
17.4
70.5
19.6
87.7
24.4
16.1
65.4
18.2
81.4
22.6
14.9
60.4
16.8
75.2
20.9
13.8
55.7
15.5
69.3
19.3
12.6
51.2
14.2
63.7
17.7
11.6
46.8
13.0
58.2
16.2
9.6
38.7
10.7
48.1
13.4
7.7
31.3
8.7
39.0
10.8
6.9
27.9
7.8
34.8
9.7
6.1
24.8
6.9
30.8
8.6
5.4
21.8
6.0
27.1
7.5
4.7
19.0
5.3
23.6
6.6
289
325
405

Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on 90% Mechanical Efficiency. *Operation below 150
RPM requires an optional externally-mounted electric motor-driven auxillary lubrication system.
The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own
evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that
stipulated in National Oilwell Standard Terms and Conditions of Sale.

Authorized Distributor:

www.natoil.com / customer.service@natoil.com
10000 Richmond, Houston, Texas 77042
(713)346-7500 (phone) (713)346-7366 (fax)

622T-8 Triplex Plunger Pump


OIL LEVEL GAUGE

Specifications

1.13
TYP
6 PLACES

27.44

20.00
TYP

C/2
C
DISCHARGE
D

C
D
SUCTION
20.00
TYP

23.37

D/2

15.05

ROTATI0N DIRECTION

1.750 x .875 KEYWAY


12.000 LONG
7.000
6.999

622T-8L & 622T-8MS

DISCHARGE
CONNECTION

G
A

A
36.16

18.00

H
1.25
TYP

11.00

10.00
SUCTION
CONNECTION
18.75

49.00

Pump Model
622T-8XL
622T-8L
622T-8MS

Flange Connections
Discharge Connection Sizes Suction Connection Sizes
A
6 (152.4)-600# ANSI FF
10 (254)-600# ANSI FF
11 1/2
4 (101.6)-1500# ANSI RF
8 (203.2)-900# ANSI FF
14 1/2
3 (76.2)-2500# ANSI RTJ
6 (152.4)-1500# ANSI RF
7 15/16

B
15 1/4
20 1/4
9 1/2

Pump Size:
maximum plunger size x stroke length, in.(mm):
7.000 x 8.000 (177.8 x 203.2)
Rated BHP (kW) at 260 RPM: 622 (464)
Rated plunger load, pounds (kg): 35500(16103)
Maximum discharge pressure: psi (kPa)
XL model: 1640 (11307)
L model: 2502 (17254)
M model: 4279 (29505)
MS model: 7232 (49863)
Crankshaft extension:
Diameter, in.(mm): 7.000 (177.8)
Length, in.(mm): 12.000 (304.8)
Keyway: width x depth, in.(mm):
1 3/4 x 7/8 (44.45 x 22.22)
Maximum recommended sheave diameter,
in.(mm): 71 (1803.4)
For larger sizes: Contact Customer Service
Accessory gear reduction unit: N/A
Oil Capacity, gallons (L)
Crankcase: 48 (181.7)
Gear Reducer - varies with ratio: N/A
Weight, pump only on
wood shipping skids, pounds (kg) 11125 (5046.3)
Weight varies with pump model
Standard Materials for Fluid Ends:
XL model
Cast Nickel-Aluminum-Bronze
Cast Carbon Steel
Cast Duplex Stainless Steel
L & M models
Forged Nickel-Aluminum-Bronze
Forged & Plate Carbon Steel
MS model
Forged Nickel-Aluminum-Bronze
Forged Carbon Steel

Dimensions (Inches)
C
D
E
41
41
62 1/4
46 1/2 46 1/2
65
39
51 1/2
65

F
G
H
94 1/4 20 3/4 7 1/4
93
20 5/8 11 1/2
93
17 3/16 -3/4

622T-8 Triplex Plunger Pump


Performance Data
PUMP

622T-8XL
(T600-7)

622T-8L
(T600-5)

622T-8M
(T600-4)

622T-8MS
(T600-3)

PUMP

622T-8XL
(T600-7)

622T-8L
(T600-5)

622T-8M
(T600-4)

622T-8MS
(T600-3)

English Units
Plunger
Plunger
BPD
Dia.
Area
per
In.
Sq. In.
RPM
7.000
38.4845 137.0875
6.750
35.7847 127.4704
6.500
33.1830 118.2030
6.250
30.6796 109.2853
6.000
28.2743 100.7174
5.750
25.9672
92.4991
5.500
23.7583
84.6306
5.250
21.6475
77.1117
5.000
19.6349
69.9426
4.750
17.7205
63.1232
4.500
15.9043
56.6535
4.250
14.1862
50.5335
4.000
12.5664
44.7633
3.750
11.0447
39.3427
3.500
9.6211
34.2719
3.250
8.2958
29.5508
3.000
7.0686
25.1793
2.750
5.9396
21.1576
2.500
4.9087
17.4857
Brake Horsepower Required

GPM
per
RPM
3.9984
3.7179
3.4476
3.1875
2.9376
2.6979
2.4684
2.2491
2.0400
1.8411
1.6524
1.4739
1.3056
1.1475
0.9996
0.8619
0.7344
0.6171
0.5100

Max.
Press.
PSI
922
992
1070
1157
1256
1367
1494
1640
1808
2003
2232
2502
2825
3214
3690
4279
5022
5977
7232

Metric Units
Plunger
Plunger
Dia.
Area
mm
cm2
178
248.286
171
230.868
165
214.084
159
197.932
152
182.415
146
167.530
140
153.279
133
139.661
127
126.677
121
114.326
114
102.608
108
91.524
102
81.073
95
71.256
89
62.072
83
53.521
76
45.604
70
38.320
64
31.669
Kilowatts Required

L/Sec.
per
RPM
0.2523
0.2346
0.2175
0.2011
0.1853
0.1702
0.1557
0.1419
0.1287
0.1162
0.1042
0.0930
0.0824
0.0724
0.0631
0.0544
0.0463
0.0389
0.0322

100 RPM
Max.
Press.
kPa M3/Hr L/Sec.
6360
90.8
25.2
6840
84.4
23.5
7376
78.3
21.8
7978
72.4
20.1
8657
66.7
18.5
9426
61.3
17.0
10302 56.1
15.6
11307 51.1
14.2
12466 46.3
12.9
13813 41.8
11.6
15390 37.5
10.4
17254 33.5
9.3
19478 29.7
8.2
22161 26.1
7.2
25440 22.7
6.3
29505 19.6
5.4
34627 16.7
4.6
41209 14.0
3.9
49863 11.6
3.2
179

M3/Hr
per
RPM
0.9080
0.8443
0.7829
0.7239
0.6671
0.6127
0.5606
0.5108
0.4633
0.4181
0.3753
0.3347
0.2965
0.2606
0.2270
0.1957
0.1668
0.1401
0.1158

100 RPM

BPD GPM
13709 399.8
12748 371.8
11821 344.8
10929 318.7
10072 293.8
9250 269.8
8464 246.8
7712 224.9
6995 204.0
6313 184.1
5666 165.2
5054 147.4
4477 130.6
3935 114.7
3428 100.0
2956
86.2
2518
73.4
2116
61.7
1749
51.0
240

150 RPM

175 RPM

BPD GPM
20564 599.8
19121 557.7
17731 517.1
16393 478.1
15108 440.6
13875 404.7
12695 370.3
11567 337.4
10492 306.0
9469
276.2
8499
247.9
7581
221.1
6715
195.8
5902
172.1
5141
149.9
4433
129.3
3777
110.2
3174
92.6
2623
76.5
359

BPD
GPM
23991
699.7
22308
650.6
20686
603.3
19125
557.8
17626
514.1
16188
472.1
14811
432.0
13495
393.6
12240
357.0
11047
322.2
9915
289.2
8844
257.9
7834
228.5
6885
200.8
5998
174.9
5172
150.8
4407
128.5
3703
108.0
3060
89.2
419

150 RPM

200 RPM

BPD
27418
25495
23641
21858
20144
18500
16927
15423
13989
12625
11331
10107
8953
7869
6855
5911
5036
4232
3498

175 RPM

M3/Hr L/Sec.
136.2
37.8
126.6
35.2
117.4
32.6
108.6
30.2
100.1
27.8
91.9
25.5
84.1
23.4
76.6
21.3
69.5
19.3
62.7
17.4
56.3
15.6
50.2
13.9
44.5
12.4
39.1
10.9
34.1
9.5
29.4
8.2
25.0
6.9
21.0
5.8
17.4
4.8
268

M3/Hr
158.9
147.8
137.0
126.7
116.7
107.2
98.1
89.4
81.1
73.2
65.7
58.6
51.9
45.6
39.7
34.3
29.2
24.5
20.3

L/Sec.
44.1
41.0
38.1
35.2
32.4
29.8
27.3
24.8
22.5
20.3
18.2
16.3
14.4
12.7
11.0
9.5
8.1
6.8
5.6
312

GPM
799.7
743.6
689.5
637.5
587.5
539.6
493.7
449.8
408.0
368.2
330.5
294.8
261.1
229.5
199.9
172.4
146.9
123.4
102.0
478

200 RPM

M3/Hr
181.6
168.9
156.6
144.8
133.4
122.5
112.1
102.2
92.7
83.6
75.1
66.9
59.3
52.1
45.4
39.1
33.4
28.0
23.2

225 RPM

BPD
30845
28681
26596
24590
22662
20813
19042
17351
15738
14203
12748
11371
10072
8853
7712
6649
5666
4761
3935

GPM
899.6
836.5
775.7
717.2
661.0
607.0
555.4
506.0
459.0
414.2
371.8
331.6
293.8
258.2
224.9
193.9
165.2
138.8
114.7
538

225 RPM

260 RPM

BPD
GPM
35643 1039.6
33143 966.7
30733 896.4
28415 828.7
26187 763.8
24050 701.5
22004 641.8
20050 584.8
18186 530.4
16413 478.7
14730 429.6
13139 383.2
11639 339.5
10230 298.3
8911
259.9
7684
224.1
6547
190.9
5501
160.4
4547
132.6
622

260 RPM

L/Sec. M3/Hr L/Sec. M3/Hr L/Sec.


50.5
204.3
56.8
236.1
65.6
46.9
190.0
52.8
219.5
61.0
43.5
176.2
48.9
203.6
56.6
40.2
162.9
45.2
188.2
52.3
37.1
150.1
41.7
173.5
48.2
34.0
137.9
38.3
159.3
44.3
31.1
126.1
35.0
145.7
40.5
28.4
114.9
31.9
132.8
36.9
25.7
104.2
29.0
120.5
33.5
23.2
94.1
26.1
108.7
30.2
20.8
84.4
23.5
97.6
27.1
18.6
75.3
20.9
87.0
24.2
16.5
66.7
18.5
77.1
21.4
14.5
58.6
16.3
67.8
18.8
12.6
51.1
14.2
59.0
16.4
10.9
44.0
12.2
50.9
14.1
9.3
37.5
10.4
43.4
12.0
7.8
31.5
8.8
36.4
10.1
6.4
26.1
7.2
30.1
8.4
357
401
464

Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on 90% Mechanical Efficiency.
The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own
evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that
stipulated in National Oilwell Standard Terms and Conditions of Sale.

Authorized Distributor:

www.natoil.com / customer.service@natoil.com
10000 Richmond, Houston, Texas 77042
(713)346-7500 (phone) (713)346-7366 (fax)

625Q-7 Quintuplex Plunger Pump


Specifications

1 1/4"x 5/8" KEYWAY

5.998
DIA.
6.000

SUCTION & DISCHARGE CONNECTIONS


MAY BE MADE AT EITHER END

14 7/8 (USABLE SHAFT EXT.)

10 3/4

57 21/32

"H" FLUID END ONLY

45 7/8

"C"/2

10 3/4

34 7/8

22 15/16

14 3/8

"C"

"C"

108 1/2

14 3/8

34 7/8

Pump Size
maximum plunger size x stroke length, in.(mm):
5 x 7 (127 x 178)
Rated bhp at 286 rpm (kw): 625 (466)
Rated plunger load, pounds(Kg): 22,200(10,070)
Maximum discharge pressure: psi(kPa)
L model: 1550 (10,687)
M model: 3150 (21,719)
H model: 5000 (34,474)
Crankshaft extension: in.(mm)
Diameter: 6 (152.4)
Length long side: 14 7/8 (378)
Length short side: 7 5/8 (194)
Keyway (width x depth):
1 1/4 x 5/8 (31.8 x 15.9)
Oil Capacity, gallons (L): 33 1/2 (127)
Weight, pump only on
wood shipping skids, pounds (Kg): 17166 (7487)
Weight varies with pump model

7 1/2

5 1/4
7 5/8 (USABLE SHAFT EXT.)

1 1/4" x 5/8" KEYWAY

1 1/2 " DIA. HOLE THRU


4 PLACES AS, SHOWN

"H" FLUID END ONLY

1" STD. PIPE TAP


1 HOLE, THIS SIDE

16

"B"

1" NPT
(1 EACH SIDE)

13 3/4

29 9/16

"A"

DISCHARGE
CENTERLINE

SUCTION
CENTERLINE
2" NPT
(CRADLE DRAIN)

52 1/8

15

12 1/2

61 1/4
17

"D"
"E"
"H" CYLINDER SUCTION DIM. ONLY

Pump Model
625Q-7L
625Q-7M
625Q-7H

Flange Connections
Discharge Connection Sizes Suction Connection Sizes
A
6 (152.4) API 2000 RJ
10 (254) ANSI 150 FF
10 1/4
4 (101.6) ANSI 1500 RJ
6 (152.4) ANSI 300 FF
5 1/4
3 (76.2) ANSI 2500 RJ
6 (152.4) ANSI 300 FF
5 1/4

Dimensions in inches (mm)


B
C
D
E
10 3/4 69 1/4
65 3/8
90 3/8
8 3/4
66 1/2
64 5/8
87 7/8
8 3/4
60 3/4
64 7/8
100 3/8

625Q-7 Quintuplex Plunger Pump


Performance Data
PUMP

625Q-7L

625Q-7M

625Q-7H

PUMP

625Q-7L

625Q-7M

625Q-7H

English Units
Plunger
Plunger
BPD
Dia.
Area
per
In.
Sq. In.
RPM
5.000
19.6349
102.000
4.750
17.7205
92.055
4.500
15.9043
82.620
4.250
14.1862
73.695
4.000
12.5664
65.280
3.750
11.0447
57.375
3.500
9.6211
49.980
3.250
8.2958
43.095
3.000
7.0686
36.720
3.000
7.0686
36.720
2.750
5.9396
30.855
2.500
4.9087
25.500
2.375
4.4301
23.014
Brake Horsepower Required

GPM
per
RPM
2.9750
2.6849
2.4097
2.1494
1.9040
1.6734
1.4577
1.2569
1.0710
1.0710
0.8999
0.7437
0.6712

100 RPM
Max.
Press.
PSI
BPD GPM
1131 10200 297.5
1253
9206 268.5
1396
8262 241.0
1550
7370 214.9
1767
6528 190.4
2010
5738 167.3
2307
4998 145.8
2676
4310 125.7
3150
3672 107.1
3150
3672 107.1
3738
3086
90.0
4523
2550
74.4
5000
2302
67.1
219

Metric Units
Plunger
Plunger
Dia.
Area
mm
cm2
127
126.677
121
114.326
114
102.608
108
91.524
102
81.073
95
71.256
89
62.072
83
53.521
76
45.604
76
45.604
70
38.320
64
31.669
60
28.581
Kilowatts Required

L/Sec.
per
RPM
0.1877
0.1694
0.1520
0.1356
0.1201
0.1056
0.0920
0.0793
0.0676
0.0676
0.0568
0.0469
0.0423

100 RPM
150 RPM
Max.
Press.
kPa M3/Hr L/Sec. M3/Hr L/Sec.
7796
67.6
18.8 101.3
28.2
8638
61.0
16.9
91.5
25.4
9624
54.7
15.2
82.1
22.8
10687 48.8
13.6
73.2
20.3
12181 43.2
12.0
64.9
18.0
13859 38.0
10.6
57.0
15.8
15909 33.1
9.2
49.7
13.8
18451 28.5
7.9
42.8
11.9
21719 24.3
6.8
36.5
10.1
21719 24.3
6.8
36.5
10.1
25770 20.4
5.7
30.7
8.5
31182 16.9
4.7
25.3
7.0
34474 15.2
4.2
22.9
6.4
163
245

M3/Hr
per
RPM
0.6756
0.6097
0.5473
0.4881
0.4324
0.3800
0.3311
0.2854
0.2432
0.2432
0.2044
0.1689
0.1524

150 RPM

BPD
15300
13809
12393
11055
9792
8607
7497
6465
5508
5508
4629
3825
3453

200 RPM

GPM
446.2
402.7
361.5
322.4
285.6
251.0
218.7
188.5
160.6
160.6
135.0
111.6
100.7
328

BPD
20400
18411
16524
14739
13056
11475
9996
8619
7344
7344
6171
5100
4603

GPM
595.0
537.0
481.9
429.9
380.8
334.7
291.5
251.4
214.2
214.2
180.0
148.7
134.2
437

200 RPM

M3/Hr
135.1
121.9
109.5
97.6
86.5
76.0
66.2
57.1
48.6
48.6
40.9
33.8
30.5

L/Sec.
37.5
33.9
30.4
27.1
24.0
21.1
18.4
15.9
13.5
13.5
11.4
9.4
8.5
326

250 RPM

BPD
25500
23014
20655
18424
16320
14344
12495
10774
9180
9180
7714
6375
5754

GPM
743.7
671.2
602.4
537.4
476.0
418.4
364.4
314.2
267.7
267.7
225.0
185.9
167.8
545

250 RPM

M3/Hr
168.9
152.4
136.8
122.0
108.1
95.0
82.8
71.4
60.8
60.8
51.1
42.2
38.1

275 RPM

BPD
28050
25316
22721
20267
17952
15779
13745
11852
10098
10098
8486
7013
6329

GPM
818.1
738.4
662.7
591.1
523.6
460.2
400.9
345.7
294.5
294.5
247.5
204.5
184.6
600

275 RPM

286 RPM

BPD
GPM
29172 850.8
26328 767.9
23630 689.2
21077 614.7
18671 544.5
16410 478.6
14295 416.9
12326 359.5
10502 306.3
10502 306.3
8825
257.4
7293
212.7
6582
192.0
625

286 RPM

L/Sec. M3/Hr L/Sec. M3/Hr L/Sec.


46.9
185.8
51.6
193.2
53.7
42.3
167.7
46.6
174.4
48.4
38.0
150.5
41.8
156.5
43.5
33.9
134.2
37.3
139.6
38.8
30.0
118.9
33.0
123.7
34.4
26.4
104.5
29.0
108.7
30.2
23.0
91.0
25.3
94.7
26.3
19.8
78.5
21.8
81.6
22.7
16.9
66.9
18.6
69.6
19.3
16.9
66.9
18.6
69.6
19.3
14.2
56.2
15.6
58.5
16.2
11.7
46.4
12.9
48.3
13.4
10.6
41.9
11.6
43.6
12.1
406
447
466

Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on 90% Mechanical Efficiency. Not all plunger sizes are shown. Contact National-Oilwell for
additional information. For Operations below 100 RPM, an auxiliary lubrication system is required.
The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own
evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that
stipulated in National Oilwell Standard Terms and Conditions of Sale.

Authorized Distributor:

www.natoil.com / customer.service@natoil.com
10000 Richmond, Houston, Texas 77042
(713)346-7500 (phone) (713)346-7366 (fax)

D-750L Triplex Piston Pump


2.0-11.5NPT
CONNECTIONS FOR PRESSURE
GAUGE AND RELIEF VALVE

1.25-11.5NPT
BOTH ENDS
WATER SPRAY
CONNECTION

3.7513.7
49 TYP

Specifications
6.0-CL-150 RF FLANGE
SUCTION CONNECTION
(OTHER FLANGES AVAILABLE)

14.62

18

18.88

67.00

36

37.75

7.50

7.12
4.0-API 5000 LB. FLANGE
DISCHARGE CONNECTION
(OTHER FLANGES AVAILABLE)

1.0 x .5 x 5.25 LONG


KEYWAY TYP

36.50

19.56

19.69

24.84

11.63

13.00

10.13

10.00

17.13

9.00

32.00

52.50

107.75

Pump Model
D-750L

Flange Connections
Discharge Connection Sizes
Suction Connection Sizes
4 (101.6) API 5000#
6 (152.4) ANSI 150# RF

44.00

Pump Type:
Horizontal Reciprocating Power Pump
Positive Displacement with
Single-Acting Pistons
Maximum Input Horsepower: 750 Continuous
Stroke Length: 8 inches
Maximum Rod Load: 85,000 Ibs.
Approximate Weight: 11,500 Ibs.
Pump Power End:
Fabricated of High Strength Steel
Gears: Double Helical
Gear Ratio: 4.95:1
Rod Bearings: Shell Type Replaceable
Main Bearings: Straight Roller
Pinion Bearings: Spherical Roller
Crankshaft: One Piece Forged Alloy Steel
Connecting Rod: One Piece Forging
Crosshead Guide: Bronze Replaceable
Fluid End:
Piston Type Segmented Block Design.
Machined From High Strength Alloy Steel,
Heat Treated and Ultrasonic Tested
Piston Diameter: 4.5 to 7 inches
Discharge Outlet: 4 API 5000 RJ
Suction Inlet: 6 ANSI 150 RF
Valves and Seats: API-6 Stem Guided,
Hardened Steel Seats
Piston Liners: Chrome or Ceramic Sleeved
Power End Lubrication:
35 GPM Required, Optional Hydraulic
Lubrication System w/ Sump Available

D-750L Triplex Piston Pump


Performance Data
Pump Speed in Crankshaft Revolutions Per Minute (RPM)
Displacement
60
80
100
120
140***
Piston
Factors*
Flow
Max
Flow
Max
Flow
Max
Flow
Max
Flow
Max
Diameter @ 100% V. E. @ 100% V. E. Press. @ 100% V. E. Press. @ 100% V. E. Press. @ 100% V. E. Press. @ 100% V. E. Press.
U.S. Gal.
U.S. Gal.
@ Flow
U.S. Gal.
@ Flow
U.S. Gal.
@ Flow
U.S. Gal.
@ Flow
U.S. Gal.
@ Flow
per Rev.
per Min.
per Min.
per Min.
per Min.
per Min.
Inches
GPR
GPM
PSIG
GPM
PSIG
GPM
PSIG
GPM
PSIG
GPM
PSIG
7.00
3.999
240
2211
320
2209
400
2208
480
2208
560
1952
6.50
3.448
207
2563
276
2562
345
2561
414
2560
483
2264
6.00
2.938
176
3008
235
3006
294
3005
353
3004
411
2657
5.50
2.468
148
3581
197
3579
247
3577
296
3576
346
3162
5.00
2.040
122
4333
163
4330
204
4328
245
4327
286
3826
4.50
1.652
99
5000
132
5000
165
5000
198
5000
231
4724
Input
Brake**
364
485
606
727
750
Power
Horsepower
Pinion RPM
297
396
495
594
693
@ 4.95:1 Gear Ratio
*V.E. = VOLUMETRIC EFFICIENCY, **BHP (Brake Horsepower) is based on 85% Mechanical Efficiency *** Speeds above 120 RPM are not recommended for continuous drilling operations.
The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own
evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that
stipulated in National Oilwell Standard Terms and Conditions of Sale.

Authorized Distributor:

www.natoil.com / customer.service@natoil.com
10000 Richmond, Houston, Texas 77042
(713)346-7500 (phone) (713)346-7366 (fax)

C-1000 Triplex Plunger Pump


21.84

Specifications
13.28

Pump Type:
Horizontal Reciprocating Power Pump,
Positive Displacement with
Single-Acting Plungers
Maximum Input Horsepower: 1069 Continuous
Stroke Length: 8 inches
Maximum Rod Load: 60,000 lbs.
Approximate Weight: 13,000 Ibs.
Pump Power End:
Fabricated of High Strength Steel
Gears: Double Helical
Gear Ratios: 6.35:1 or 7.0:1
Rod Bearings: Shell Type Replaceable
Main Bearings: Straight Roller
Pinion Bearings: Spherical Roller
Crankshaft: One Piece Forged Alloy Steel
Connecting Rod: One Piece Forging
Crosshead Guide: Bronze Replaceable
Fluid End: Steel Billet
Plunger Diameter: 4.5 to 6.75 inches
Discharge: 1500 lb. ANSI RF 4
Suction: 150 lb. ANSI RF 8
Valves and Seats: Stainless Steel Disc Type
Power End Lubrication:
Pressure Lubricated with Removal Oil Sump

66.17

33.63

6.88

4.00
1" NPT
(PRESSURE SWITCH)

PINION SHAFT
1.00 WIDTH BY
0.50 DEPTH KEYWAY
1" NPT
(OIL PUMP OUTLET)

95.74

61.88

25.76

4"-1500#
ANSI RF
FLANGE
TYP BOTH SIDES

19.06

11.14

44.31

15.89

22.81

11.81

ROTATION
6.75

8" - 150# ANSI RF FLANGE

12.06

12.81

TYP BOTH SIDES

2" FNPT CONNECTION


(DRAIN)

30.28

33.00

37.00

Pump Model
C-1000

18.50

22.50

26.50

Flange Connections
Discharge Connection Sizes
Suction Connection Sizes
4 (101.6) 1500# ANSI RF
8 (203.2) 150# ANSI RF

C-1000 Triplex Plunger Pump


Performance Data
Plunger
Diameter
Inches
4.5
5
5.5
6
6.5
6.75

Maximum
Pressure
psi

Displacement
U.S.Gallon
per
Rev.

3705
1.6524
3055
2.0400
2525
2.4684
2120
2.9376
1810
3.4476
1675
3.779
Minimum Brake Horsepower Required

50
RPM
GPM
83
102
123
147
172
186
214

Pump Speed in Crankshaft Revolutions Per Minute (RPM)


Displacement
100
150
200
RPM
RPM
RPM
GPM
GPM
GPM
165
248
330
204
306
408
247
370
494
294
441
588
345
517
690
372
558
744
427
641
855

250
RPM
GPM
413
510
617
734
862
929
1069

Brake Horsepower is based on 85% Mechanical Efficiency at the Pinion Shaft. RPM shown is crankshaft speed. For pinion shaft speed, multiply RPM by Gear Ratio.
Displacement is based on 100% Volumetric Efficiency.
The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own
evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that
stipulated in National Oilwell Standard Terms and Conditions of Sale.

Authorized Distributor:

www.natoil.com / customer.service@natoil.com
10000 Richmond, Houston, Texas 77042
(713)346-7500 (phone) (713)346-7366 (fax)

535 Duplex Double-Acting Piston Pump


.75
TYP
4 PLACES

Specifications

8.06
6.13
12.25
C
C/2
12.25

DISCHARGE
CONNECTION

.375 X .188 KEYWAY


4.000 LONG

1.500
1.499

6.42
PINION SHAFT
ROTATION
DIRECTION

Pump Size:
maximum piston size x stroke length, in.(mm):
3.500 x 5.125 (88.9 x 130.2)
Rated BHP (kW) at 85 RPM (Crankshaft speed):
12.4 (9.3)
Rated piston load, pounds (kg): 2500 (1134)
Maximum discharge pressure, psi (kPa):
796 (5487)
Pinion Gear Ratio : 4.933:1
Pinion shaft extension:
Diameter, in. (mm): 1.500 (38.10)
Length, in. (mm): 4.188 (4.76)
Keyway width x depth, in.(mm):
3/8 x 3/16 (9.525 x 4.763)
Maximum recommended sheave diameter,
in.(mm): 25.0 (635.0)
For larger sheave diameters:
Contact Customer Service
Oil Capacity, gallons (L): 1.25 (4.7)
Weight, pump only on
wood shipping skids, pounds (kg): 800 (363)
Standard Materials for Fluid End Bodies
Cast Gray Iron
Cast Ductile Iron

F
A
17.25

12.46
8.75

SUCTION
CONNECTION

.75
TYP

.37

D
8.13
40.50 SUCTION
E

Pump Model
535

Flange Connections
Discharge Connection Sizes Suction Connection Sizes
A
B
6 7/16 4 1/2
2 (50.8)-8 NPT
2 1/2 (63.5)-8 NPT

C
20

Dimensions (Inches)
D
E
F
34 1/4 50 7/8

33 3/8

2 5/8

31 1/4 13 3/4

535 Duplex Double-Acting Piston Pump


Performance Data
PUMP

535

PUMP

535

English Units
Piston
Piston
BPD
Dia.
Area
per
In.
Sq. In.
RPM
2.000
3.1416
8.3623
2.500
4.9087
13.7383
3.000
7.0686
20.3074
3.500
9.6211
28.0766
Brake Horsepower Required

GPM
per
RPM
0.2439
0.4007
0.5923
0.8189

Metric Units
Plunger
Plunger
Dia.
Area
mm
cm2
51
20.268
64
31.669
76
45.604
89
62.072
Kilowatts Required

L/Sec.
per
RPM
0.0154
0.0253
0.0374
0.0517

M3/Hr
per
RPM
0.0554
0.0910
0.1345
0.1860

25 RPM
Max.
Press.
PSI
796
509
354
260

BPD
210
344
508
702

GPM
6.1
10.0
14.8
20.5
3.7

40 RPM

BPD
335
550
813
1124

55 RPM

GPM
9.8
16.0
23.7
32.8
5.9

BPD
460
756
1117
1545

GPM
13.4
22.0
32.6
45.0

70 RPM

BPD
586
962
1422
1966

8.0

25 RPM
40 RPM
Max.
Press.
kPa M3/Hr L/Sec. M3/Hr L/Sec.
5487
1.4
0.4
2.2
0.6
3511
2.3
0.6
3.6
1.0
2439
3.4
0.9
5.4
1.5
1792
4.6
1.3
7.4
2.1
2.7
4.4

55 RPM

M3/Hr
3.0
5.0
7.4
10.2

L/Sec.
0.8
1.4
2.1
2.8
6.0

GPM
17.1
28.0
41.5
57.3
10.2

70 RPM

M3/Hr
3.9
6.4
9.4
13.0

85 RPM

BPD
711
1168
1727
2387

GPM
20.7
34.1
50.3
69.6
12.4

85 RPM

L/Sec. M3/Hr L/Sec.


1.1
4.7
1.3
1.8
7.7
2.1
2.6
11.4
3.2
3.6
15.8
4.4
7.6
9.3

RPM shown is Crankshaft speed. For Pinion Shaft speed, multiply RPM by Gear Ratio. Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on
85% Mechanical Efficiency.
The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own
evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that
stipulated in National Oilwell Standard Terms and Conditions of Sale.

Authorized Distributor:

www.natoil.com / customer.service@natoil.com
10000 Richmond, Houston, Texas 77042
(713)346-7500 (phone) (713)346-7366 (fax)

1847-A Duplex Double-Acting Piston Pump


3.75
MTG.PFEET

Specifications
Pump Size:
maximum piston size x stroke length, in.(mm):
4-1/2 x 6 (114.3 x 152.4)
Rated BHP (kW) at 100 RPM (Crankshaft speed):
33 (25)
Rated piston load, pounds (kg): 4850 (2200)
Maximum discharge pressure, psi (kPa):
990 (6826)
Pinion gear ratio: 5.100:1
Pinion shaft extension:
Diameter, in.(mm): 1.750 (44.45)
Length, in.(mm): 5.625 (142.88)
Keyway width x depth, in.(mm):
3/8 x 3/16 (9.525 x 4.763)
Maximum recommended sheave diameter,
in.(mm): 38 (965)
For larger sheave diameters:
Contact Customer Service
Oil Capacity, gallons (L): 5.0 (18.9)
Weight, pump only on
wood shipping skids, pounds (kg): 1960 (889)
Standard Materials for Fluid End Bodies
Cast Steel
Cast Ductile Iron

5.65
3.50
13.25

15.50PM
TG.PFEET

7.75PMT
G.PFEET
C

3.50

13.25

%%C.750PTYPP6
PLACES

3.75
MTG.PFEET

.375 x .188 KEYWAYP6.125


LONG

%%C2.499
^2.500;

6.53

DIRECTION
ROTATION

DISCHARGEPCONNEC
TION

POF

23.06
F

A
19.63

17.16
9.75

1.25

.88
2.00
5.00

SUCTIONPCONNECTI
ON

14.63
5.00
D

Pump Model
1847-A

Flange Connections

Dimensions (Inches)

Discharge Connection Sizes

Suction Connection Sizes

By-Pass Connection Sizes

2 (50.8)-600# ANSI FF

4 (101.6)-150# ANSI FF

None

7 1/4

8 5/8

26 1/2

42 5/8

65 15/16

11 7/8

8 5/8

1847-A Duplex Double-Acting Piston Pump


Performance Data
PUMP

1847-A

PUMP

1847-A

English Units
Piston
Piston
BPD
Dia.
Area
per
In.
Sq. In.
RPM
2.500
4.9087
15.7680
3.000
7.0686
23.4480
3.500
9.6211
32.3520
4.000
12.5664
42.9120
4.500
15.9043
54.8640
Brake Horsepower Required

GPM
per
RPM
0.4599
0.6839
0.9436
1.2516
1.6002

Metric Units
Plunger
Plunger
Dia.
Area
mm
cm2
64
31.669
76
45.604
89
62.072
102
81.073
114
102.608
Kilowatts Required

L/Sec.
per
RPM
0.0290
0.0431
0.0595
0.0790
0.1010

M3/Hr
per
RPM
0.1044
0.1553
0.2143
0.2842
0.3634

20 RPM
Max.
Press.
PSI
990
686
504
386
305

BPD
316
469
648
859
1098

GPM
9.2
13.7
18.9
25.0
32.0
7

40 RPM

BPD
631
938
1295
1717
2195

60 RPM

GPM
18.4
27.4
37.7
50.1
64.0

BPD
947
1407
1942
2575
3292

13

20 RPM
40 RPM
Max.
Press.
kPa M3/Hr L/Sec. M3/Hr L/Sec.
6812
2.1
0.6
4.2
1.2
4731
3.1
0.9
6.2
1.7
3476
4.3
1.2
8.6
2.4
2661
5.7
1.6
11.4
3.2
2103
7.3
2.0
14.5
4.0
5
10

GPM
27.6
41.0
56.6
75.1
96.0

80 RPM

BPD
1262
1876
2589
3433
4390

GPM
36.8
54.7
75.5
100.1
128.0

100 RPM

BPD
1577
2345
3236
4292
5487

GPM
46.0
68.4
94.4
125.2
160.0

20

27

33

60 RPM

80 RPM

100 RPM

M3/Hr
6.3
9.3
12.9
17.1
21.8

L/Sec.
1.7
2.6
3.6
4.7
6.1
15

M3/Hr
8.4
12.4
17.1
22.7
29.1

L/Sec. M3/Hr L/Sec.


2.3
10.4
2.9
3.5
15.5
4.3
4.8
21.4
6.0
6.3
28.4
7.9
8.1
36.3
10.1
20
25

RPM shown is Crankshaft speed. For Pinion Shaft speed, multiply RPM by Gear Ratio. Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on
85% Mechanical Efficiency.
The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own
evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that
stipulated in National Oilwell Standard Terms and Conditions of Sale.

Authorized Distributor:

www.natoil.com / customer.service@natoil.com
10000 Richmond, Houston, Texas 77042
(713)346-7500 (phone) (713)346-7366 (fax)

1550 Duplex Double-Acting Piston Pump


Specifications
SHAFT

15.00
TYP
10.50

6.75
CL

31.00

PUMP

PINION SHAFT

21.00

13.50

CRANK

4.13

22.63

1.00
TYP
6 PLACES
2.500
2.499

.625 X .313 KEYWAY

DISCHARGE CONNECTION
3.00 - 600# ANSI

PINION
ROTATION

14.25
8.75

32.18

28.00
22.00
9.25
14.25
2.00
TYP
5.00

1.75
11.50
SUCTION CONNECTION
4.00-150# ANSI
42.75
7.13
TYP

62.90

93.00

Pump Model
1550

Flange Connections
Discharge Connection Sizes
Suction Connection Sizes
3 (76.2) 600# ANSI
4 (101.6) 150# ANSI

10.10

Pump Size:
maximum piston size x stroke length, in.(mm):
5 x 10 (127.0 x 254.0)
Rated BHP (kW) at 85 RPM (Crankshaft speed):
74 (55)
Rated piston load, pounds (kg): 7475 (3391)
Maximum discharge pressure, psi (kPa):
1440 (9929)
Pinion gear ratio: 5.92:1
Pinion shaft extension:
Diameter, in.(mm): 2.500 (61.25)
Length, in.(mm): 6.813 (173.0)
Keyway: Width x Depth, in.(mm):
5/8 x 5/16 (15.875 x 7.938)
Maximum recommended sheave diameter,
in.(mm): 44 (1118)
For larger sheave diameters:
Contact Customer Service
Oil Capacity, gallons (L): 10.0 (37.85)
Weight, pump only on
wood shipping skids, pounds (kg): 3705 (1681)
Standard Materials for Fluid End Bodies
Cast Carbon Steel
Cast Ductile Iron

1550 Duplex Double-Acting Piston Pump


Performance Data
PUMP

1550

PUMP

1550

English Units
Piston
Piston
BPD
Dia.
Area
per
In.
Sq. In.
RPM
2.500
4.9087
26.1908
3.000
7.0686
39.0137
3.500
9.6211
54.1680
4.000
12.5664
71.6537
4.500
15.9043
91.4708
5.000
19.6349 113.6194
Brake Horsepower Required

GPM
per
RPM
0.7639
1.1379
1.5799
2.0899
2.6679
3.3139

Metric Units
Plunger
Plunger
Dia.
Area
mm
cm2
64
31.669
76
45.604
89
62.072
102
81.073
114
102.608
127
126.677
Kilowatts Required

L/Sec.
per
RPM
0.0482
0.0718
0.0997
0.1319
0.1683
0.2091

M3/Hr
per
RPM
0.1735
0.2584
0.3588
0.4746
0.6059
0.7526

25 RPM
Max.
Press.
PSI
1400
1057
777
595
470
381

BPD
655
976
1355
1792
2287
2841

GPM
19.1
28.4
39.5
52.2
66.7
82.8
22

40 RPM

BPD
1048
1561
2167
2867
3659
4545

55 RPM

GPM
30.6
45.5
63.2
83.6
106.7
132.6

BPD
1441
2146
2980
3941
5031
6250

35

25 RPM
40 RPM
Max.
Press.
kPa M3/Hr L/Sec. M3/Hr L/Sec.
9929
4.3
1.2
6.9
1.9
7291
6.5
1.8
10.3
2.9
5357
9.0
2.5
14.4
4.0
4101
11.9
3.3
19.0
5.3
3241
15.1
4.2
24.2
6.7
2625
18.8
5.2
30.1
8.4
16
26

GPM
42.0
62.6
86.9
114.9
146.7
182.3

70 RPM

BPD
1834
2731
3792
5016
6403
7954

GPM
53.5
79.7
110.6
146.3
186.8
232.0

85 RPM

BPD
2227
3317
4605
6091
7776
9658

GPM
64.9
96.7
134.3
177.6
226.8
281.7

48

61

74

55 RPM

70 RPM

85 RPM

M3/Hr
9.5
14.2
19.7
26.1
33.3
41.4

L/Sec.
2.7
3.9
5.5
7.3
9.3
11.5
36

M3/Hr
12.1
18.1
25.1
33.2
42.4
52.7

L/Sec. M3/Hr L/Sec.


3.4
14.7
4.1
5.0
22.0
6.1
7.0
30.5
8.5
9.2
40.3
11.2
11.8
51.5
14.3
14.6
64.0
17.8
45
55

RPM shown is Crankshaft speed. For Pinion Shaft speed, multiply RPM by Gear Ratio. Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on
85% Mechanical Efficiency.
The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own
evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that
stipulated in National Oilwell Standard Terms and Conditions of Sale.

Authorized Distributor:

www.natoil.com / customer.service@natoil.com
10000 Richmond, Houston, Texas 77042
(713)346-7500 (phone) (713)346-7366 (fax)

1654 Duplex Double-Acting Piston Pump


1.00
TYP
8 PLACES

14.88

14.88

Specifications

15.76

12.00

12.00

12.00

12.00
15.76

11.12

3/8" x 3/4" x 10" LONG


KEYWAY

3.000
2.999

26.08

50.12

14.88

DISCHARGE
3"-2000# API RTJ
FLANGE

10.50
ROTATION
DIRECTION

10.25
DISCHARGE

SUCTION
4"-300# ANSI
FLANGE

32.88
23.92

21.13
DISCHARGE
12.75

1.25

1.75

1.63

2.25
2.50
1" NPT
DRAIN HOLE
ON EACH CYLINDER C

11.63

5.00

22.00

3.38 SUCTION

47.75
10.00 SUCTION

Pump Model
1654

Flange Connections
Discharge Connection Sizes
Suction Connection Sizes
3 (76.2) 2000 API RTJ
4 (101.6) 3000# API RTJ

Pump Size:
maximum piston size x stroke length, in.(mm):
5 x 8 (127.0 x 203.2)
Rated BHP (kW) at 90 RPM (Crankshaft speed):
104 (77)
Rated piston load, pounds (kg): 12680 (5752)
Maximum discharge pressure, psi (kPa):
1800 (12411)
Pinion gear ratio: 4.750:1
Pinion shaft extension:
Diameter, in.(mm): 3.000 (76.20)
Length, in.(mm): 11.000 (279.40)
Keyway width x depth, in.(mm):
3/4 x 3/8 (19.05 x 9.525)
Maximum recommended sheave diameter,
in.(mm): 44 (1118)
For larger sheave diameters:
Contact Customer Service
Oil Capacity, gallons (L): 12.0 (45.42)
Weight, pump only on
wood shipping skids, pounds (kg): 4475 (2030)
Standard Materials for Fluid End Bodies
Cast Steel
Cast Ductile Iron

1654 Duplex Double-Acting Piston Pump


Performance Data
PUMP

1654

PUMP

1654

English Units
Piston
Piston
BPD
Dia.
Area
per
In.
Sq. In.
RPM
2.500
4.9087
19.1177
3.000
7.0686
29.3760
3.500
9.6211
41.4720
4.000
12.5664
55.4880
4.500
15.9043
71.3417
5.000
19.6349
89.0605
Brake Horsepower Required

GPM
per
RPM
0.5576
0.8568
1.2096
1.6184
2.0808
2.5976

Metric Units
Plunger
Plunger
Dia.
Area
mm
cm2
64
31.669
76
45.604
89
62.072
102
81.073
114
102.608
127
126.677
Kilowatts Required

L/Sec.
per
RPM
0.0352
0.0541
0.0763
0.1021
0.1313
0.1639

M3/Hr
per
RPM
0.1266
0.1946
0.2747
0.3675
0.4725
0.5899

30 RPM
Max.
Press.
PSI
1800
1794
1318
1009
797
646

BPD
574
882
1245
1665
2141
2672

GPM
16.7
25.7
36.3
48.6
62.4
77.9
35

45 RPM

BPD
861
1322
1867
2497
3211
4008

60 RPM

GPM
25.1
38.6
54.4
72.8
93.6
116.9

BPD
1148
1763
2489
3330
4281
5344

52

30 RPM
45 RPM
Max.
Press.
kPa M3/Hr L/Sec. M3/Hr L/Sec.
12411
3.8
1.1
5.7
1.6
12368
5.8
1.6
8.8
2.4
9087
8.2
2.3
12.4
3.4
6957
11.0
3.1
16.5
4.6
5497
14.2
3.9
21.3
5.9
4453
17.7
4.9
26.5
7.4
26
39

GPM
33.5
51.4
72.6
97.1
124.8
155.9

75 RPM

BPD
1434
2204
3111
4162
5351
6680

GPM
41.8
64.3
90.7
121.4
156.1
194.8

69

86

60 RPM

75 RPM

M3/Hr
7.6
11.7
16.5
22.1
28.4
35.4

L/Sec.
2.1
3.2
4.6
6.1
7.9
9.8
52

M3/Hr
9.5
14.6
20.6
27.6
35.4
44.2

90 RPM

BPD
1721
2644
3733
4994
6421
8016

GPM
50.2
77.1
108.9
145.7
187.3
233.8
104

90 RPM

L/Sec. M3/Hr L/Sec.


2.6
11.4
3.2
4.1
17.5
4.9
5.7
24.7
6.9
7.7
33.1
9.2
9.8
42.5
11.8
12.3
53.1
14.7
64
77

RPM shown is Crankshaft speed. For Pinion Shaft speed, multiply RPM by Gear Ratio. Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on
85% Mechanical Efficiency.
The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own
evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that
stipulated in National Oilwell Standard Terms and Conditions of Sale.

Authorized Distributor:

www.natoil.com / customer.service@natoil.com
10000 Richmond, Houston, Texas 77042
(713)346-7500 (phone) (713)346-7366 (fax)

1757 Plunger Pump


1.13
TYP
2 PLACES

34.67

Specifications
Pump Size:
maximum piston size x stroke length, in.(mm):
5-1/2 x 10 (139.7 x 254.0)
Rated BHP (kW) at 85 RPM (Crankshaft speed):
127 (95)
Rated piston load, pounds (kg): 13100 (5942)
Maximum discharge pressure, psi (kPa):
1750 (12066)
Pinion gear ratio: 5.846:1
Pinion shaft extension:
Diameter, in.(mm): 2.938 (74.61)
Length, in.(mm): 13.750 (349.25)
Keyway width x depth, in.(mm):
3/4 x 3/8 (19.05 x 9.525)
Maximum recommended sheave diameter,
in.(mm): 50 (1270)
For larger sheave diameters:
Contact Customer Service
Oil Capacity, gallons (L): 15.0 (56.8)
Weight, pump only on
wood shipping skids, pounds (kg): 6125 (2778)
Standard Materials for Fluid End Bodies
Cast Steel
Cast Ductile Iron

6.56

19.25
11.75
8.50
23.50

17.00

20.50

1.25
TYP
4 PLACES

.750 X .375 KAYWAY


12.750 LONG
2.938
2.939

14.89
BY-PASS
CONNECTION

DIRECTION
OF ROTATION

DISCHARGE
CONNECTION

39.50
A
34.63

28.00

B
18.25

2.25

1.00

1.25

SUCTION
CONNECTION

9.41
2.75
9.09

21.63

Pump Model
1757

Flange Connections

Dimensions (Inches)

Discharge Connection Sizes

Suction Connection Sizes

By-Pass Connection Sizes

3 (76.2)-600# ANSI FF

4 (101.6)-150# ANSI FF

None

8 1/4

38 1/2

73 3/8

111 7/16

13 5/8

13 1/4

1757 Plunger Pump


Performance Data
PUMP

1757

PUMP

1757

English Units
Piston
Piston
BPD
Dia.
Area
per
In.
Sq. In.
RPM
2.500
4.9087
23.9280
3.000
7.0686
36.6960
3.500
9.6211
51.9120
4.000
12.5664
69.3360
4.500
15.9043
89.2080
5.000
19.6349
111.288
5.500
23.7583
135.840
Brake Horsepower Required

GPM
per
RPM
0.6979
1.0703
1.5141
2.0223
2.6019
3.2459
3.9620

Metric Units
Plunger
Plunger
Dia.
Area
mm
cm2
64
31.669
76
45.604
89
62.072
102
81.073
114
102.608
127
126.677
140
153.279
Kilowatts Required

L/Sec.
per
RPM
0.0440
0.0675
0.0955
0.1276
0.1642
0.2048
0.2500

M3/Hr
per
RPM
0.1585
0.2431
0.3439
0.4593
0.5909
0.7371
0.8998

25 RPM
Max.
Press.
PSI
1750
1750
1362
1042
824
667
551

BPD
599
918
1298
1734
2231
2783
3396

GPM
17.4
26.8
37.9
50.6
65.0
81.1
99.1
37

40 RPM

BPD
958
1468
2077
2774
3569
4452
5434

GPM
27.9
42.8
60.6
80.9
104.1
129.8
158.5

55 RPM

BPD
1317
2019
2856
3814
4907
6121
7472

60

25 RPM
40 RPM
Max.
Press.
kPa M3/Hr L/Sec. M3/Hr L/Sec.
12066
4.0
1.1
6.3
1.8
12066
6.1
1.7
9.7
2.7
9388
8.6
2.4
13.8
3.8
7188
11.5
3.2
18.4
5.1
5679
14.8
4.1
23.6
6.6
4600
18.4
5.1
29.5
8.2
3802
22.5
6.2
36.0
10.0
28
45

GPM
38.4
58.9
83.3
111.2
143.1
178.5
217.9

70 RPM

BPD
1675
2569
3634
4854
6245
7791
9509

82
55 RPM

M3/Hr
8.7
13.4
18.9
25.3
32.5
40.5
49.5

L/Sec.
2.4
3.7
5.3
7.0
9.0
11.3
13.7
61

GPM
48.9
74.9
106.0
141.6
182.1
227.2
277.3
105

70 RPM

M3/Hr
11.1
17.0
24.1
32.1
41.4
51.6
63.0

85 RPM

BPD
2034
3120
4413
5894
7583
9460
11547

GPM
59.3
91.0
128.7
171.9
221.2
275.9
336.8
127

85 RPM

L/Sec. M3/Hr L/Sec.


3.1
13.5
3.7
4.7
20.7
5.7
6.7
29.2
8.1
8.9
39.0
10.8
11.5
50.2
14.0
14.3
62.7
17.4
17.5
76.5
21.2
78
95

RPM shown is Crankshaft speed. For Pinion Shaft speed, multiply RPM by Gear Ratio. Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based
on 85% Mechanical Efficiency.
The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own
evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that
stipulated in National Oilwell Standard Terms and Conditions of Sale.

Authorized Distributor:

www.natoil.com / customer.service@natoil.com
10000 Richmond, Houston, Texas 77042
(713)346-7500 (phone) (713)346-7366 (fax)

1759 Duplex Double-Acting Piston Pump


1.13
TYP
2 PLACES

34.67

Specifications
Pump Size:
maximum piston size x stroke length, in.(mm):
7-1/2 x 10 (190.5 x 254.0)
Rated BHP (kW) at 85 RPM (Crankshaft speed):
130 (97)
Rated piston load, pounds (kg): 13100 (5942)
Maximum discharge pressure, psi (kPa):
1042 (7188)
Pinion gear ratio: 5.846:1
Pinion shaft extension:
Diameter, in.(mm): 2.938 (74.61)
Length, in.(mm): 13.750 (349.25)
Keyway width x depth, in.(mm):
3/4 x 3/8 (19.05 x 9.525)
Maximum recommended sheave diameter,
in.(mm): 50 (1270)
For larger sheave diameters:
Contact Customer Service
Oil Capacity, gallons (L): 15.0 (56.8)
Weight, pump only on
wood shipping skids, pounds (kg): 7012 (3181)
Standard Materials for Fluid End Bodies
Cast Steel
Cast Ductile Iron

6.56

19.25
11.75
8.50
23.50

17.00

20.50

1.25
TYP
4 PLACES

.750 X .375 KAYWAY


12.750 LONG
2.938
2.939

14.89
BY-PASS
CONNECTION

DIRECTION
OF ROTATION

DISCHARGE
CONNECTION

39.50
A
34.63

28.00

B
18.25

2.25

1.00

1.25

SUCTION
CONNECTION

9.41
2.75
9.09

21.63

Pump Model
1759

Flange Connections

Dimensions (Inches)

Discharge Connection Sizes

Suction Connection Sizes

By-Pass Connection Sizes

4 (101.6)-150# ANSI FF

6 (152.4)-150# ANSI FF

3 (76.2)-600# ANSI FF

11 3/8

11 3/4

43 1/2

74 5/8

111 15/16

17 5/8

12 1/2

1759 Duplex Double-Acting Piston Pump


Performance Data
PUMP

1759

PUMP

1759

English Units
Piston
Piston
BPD
Dia.
Area
per
In.
Sq. In.
RPM
4.000
12.5664
69.3360
4.500
15.9043
89.2080
5.000
19.6349
111.288
5.500
23.7583
135.840
6.000
28.2743
162.576
6.500
33.1830
191.664
7.000
38.4845
223.200
7.500
44.1786
257.040
Brake Horsepower Required

GPM
per
RPM
2.0223
2.6019
3.2459
3.9620
4.7418
5.5902
6.5100
7.4970

Metric Units
Plunger
Plunger
Dia.
Area
mm
cm2
102
81.073
114
102.608
127
126.677
140
153.279
152
182.415
165
214.084
178
248.286
191
285.023
Kilowatts Required

L/Sec.
per
RPM
0.1276
0.1642
0.2048
0.2500
0.2992
0.3527
0.4107
0.4730

M3/Hr
per
RPM
0.4593
0.5909
0.7371
0.8998
1.0769
1.2695
1.4784
1.7026

25 RPM
Max.
Press.
PSI
1042
824
667
551
463
395
340
297

BPD
1734
2231
2783
3396
4065
4792
5580
6426

GPM
50.6
65.0
81.1
99.1
118.5
139.8
162.8
187.4
38

40 RPM

BPD
2774
3569
4452
5434
6504
7667
8928
10282

GPM
80.9
104.1
129.8
158.5
189.7
223.6
260.4
299.9

55 RPM

BPD
3814
4907
6121
7472
8942
10542
12276
14138

61

25 RPM
40 RPM
Max.
Press.
kPa M3/Hr L/Sec. M3/Hr L/Sec.
7188
11.5
3.2
18.4
5.1
5679
14.8
4.1
23.6
6.6
4600
18.4
5.1
29.5
8.2
3802
22.5
6.2
36.0
10.0
3194
26.9
7.5
43.1
12.0
2722
31.7
8.8
50.8
14.1
2347
37.0
10.3
59.1
16.4
2044
42.6
11.8
68.1
18.9
28
46

GPM
111.2
143.1
178.5
217.9
260.8
307.5
358.1
412.3

70 RPM

BPD
4854
6245
7791
9509
11381
13417
15624
17993

84
55 RPM

M3/Hr
25.3
32.5
40.5
49.5
59.2
69.8
81.3
93.6

L/Sec.
7.0
9.0
11.3
13.7
16.5
19.4
22.6
26.0
63

GPM
141.6
182.1
227.2
277.3
331.9
391.3
455.7
524.8
107

70 RPM

M3/Hr
32.1
41.4
51.6
63.0
75.4
88.9
103.5
119.2

85 RPM

BPD
5894
7583
9460
11547
13819
16292
18972
21849

GPM
171.9
221.2
275.9
336.8
403.1
475.2
553.4
637.2
130

85 RPM

L/Sec. M3/Hr L/Sec.


8.9
39.0
10.8
11.5
50.2
14.0
14.3
62.7
17.4
17.5
76.5
21.2
20.9
91.5
25.4
24.7
107.9
30.0
28.8
125.7
34.9
33.1
144.7
40.2
80
97

RPM shown is Crankshaft speed. For Pinion Shaft speed, multiply RPM by Gear Ratio. Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required
is based on 85% Mechanical Efficiency.
The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own
evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that
stipulated in National Oilwell Standard Terms and Conditions of Sale.

Authorized Distributor:

www.natoil.com / customer.service@natoil.com
10000 Richmond, Houston, Texas 77042
(713)346-7500 (phone) (713)346-7366 (fax)

2651 Duplex Double-Acting Piston Pump


1.25
TYP
4 PLACES

Specifications

25.69
TYP

Pump Size:
maximum piston size x stroke length, in.(mm):
5-1/2 x 12 (139.7 x 304.8)
Rated BHP (kW) at 85 RPM (Crankshaft speed):
250 (187)
Rated piston load, pounds (kg): 22100(10025)
Maximum discharge pressure, psi (kPa):
1760 (12134)
Pinion gear ratio: 5.05:1
Pinion shaft extension:
Diameter, in.(mm): 4.250 (107.95)
Length, in.(mm): 18.750 (476.25)
Keyway width x depth, in.(mm):
1 x 1/2 (25.4 x 12.7)
Maximum recommended sheave diameter,
in.(mm): 63 (1600)
For larger sheave diameters:
Contact Customer Service
Oil Capacity, gallons (L): 25.0 (94.6)
Weight, pump only on
wood shipping skids, pounds (kg): 16000(7258)
Standard Materials for Fluid End Bodies
Cast Steel

18.88
TYP

17.00
12.00

8.00
TYP

24.00

34.00

43.25

1.50
TYP
6 PLACES

4.250
4.249

13.00
BY-PASS

1.00 X 1.50 KEYWAY


16.00 LONG

DISCHARGE
CONNECTION

BY-PASS
CONNECTION
16.25
ROTATION
DIRECTION

F
52.00

45.75

39.81

B
23.50

3.50
TYP

37.88

10.00
TYP

33.62

SUCTION
CONNECTION
3 PLACES

13.00
SUCTION
61.75

Pump Model
2651

Flange Connections

Dimensions (Inches)

Discharge Connection Sizes

Suction Connection Sizes

By-Pass Connection Sizes

4 (101.6)-900# ANSI FF

8 (203.2)-300# ANSI FF

2 (50.8)-1500# ANSI FF

10 1/2

14 3/4

49 1/2

86 1/4

131 13/16

17 5/8

13 1/4

2651 Duplex Double-Acting Piston Pump


Performance Data
PUMP

2651

PUMP

2651

English Units
Piston
Piston
BPD
Dia.
Area
per
In.
Sq. In.
RPM
4.000
12.5664
78.3840
4.500
15.9043
102.096
5.000
19.6349
128.712
5.500
23.7583
158.064
Brake Horsepower Required

GPM
per
RPM
2.2862
2.9778
3.7541
4.6102

Max.
Press.
PSI
1760
1390
1126
930

Metric Units
Plunger
Plunger
Dia.
Area
mm
cm2
102
81.073
114
102.608
127
126.677
140
153.279
Kilowatts Required

L/Sec.
per
RPM
0.1442
0.1879
0.2368
0.2909

25 RPM
40 RPM
Max.
Press.
kPa M3/Hr L/Sec. M3/Hr L/Sec.
12134 13.0
3.6
20.8
5.8
9581
16.9
4.7
27.1
7.5
7760
21.3
5.9
34.1
9.5
6414
26.2
7.3
41.9
11.6
55
88

M3/Hr
per
RPM
0.5192
0.6763
0.8526
1.0470

25 RPM

BPD
1960
2553
3218
3952

GPM
57.2
74.4
93.9
115.3
74

40 RPM

BPD
3136
4084
5149
6323

55 RPM

GPM
91.4
119.1
150.2
184.4
118

BPD
4312
5616
7080
8694

GPM
125.7
163.8
206.5
253.6
162

55 RPM

M3/Hr
28.6
37.2
46.9
57.6

L/Sec.
7.9
10.3
13.0
16.0
121

70 RPM

BPD
5487
7147
9010
11065

GPM
160.0
208.4
262.8
322.7
206

70 RPM

M3/Hr
36.3
47.3
59.7
73.3

85 RPM

BPD
6663
8679
10941
13436

GPM
194.3
253.1
319.1
391.9
250

85 RPM

L/Sec. M3/Hr L/Sec.


10.1
44.1
12.3
13.2
57.5
16.0
16.6
72.5
20.1
20.4
89.0
24.7
154
187

RPM shown is Crankshaft speed. For Pinion Shaft speed, multiply RPM by Gear Ratio. Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required is based on
85% Mechanical Efficiency.
The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own
evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that
stipulated in National Oilwell Standard Terms and Conditions of Sale.

Authorized Distributor:

www.natoil.com / customer.service@natoil.com
10000 Richmond, Houston, Texas 77042
(713)346-7500 (phone) (713)346-7366 (fax)

2652 Duplex Double-Acting Piston Pump


1.25
TYP
4 PLACES

Specifications

25.69
TYP

Pump Size:
maximum piston size x stroke length, in.(mm):
7-1/4 x 12 (184.2 x 304.8)
Rated BHP (kW) at 85 RPM (Crankshaft speed):
258 (192)
Rated piston load, pounds (kg): 22100(10025)
Maximum discharge pressure, psi (kPa):
1125 (7757)
Pinion gear ratio: 5.05:1
Pinion shaft extension:
Diameter, in.(mm): 4.250 (107.95)
Length, in.(mm): 18.750 (476.25)
Keyway width x depth, in.(mm):
1 x 1/2 (25.4 x 12.7)
Maximum recommended sheave diameter,
in.(mm): 63 (1600)
For larger sheave diameters:
Contact Customer Service
Oil Capacity, gallons (L): 25.0 (94.6)
Weight, pump only on
wood shipping skids, pounds (kg): 15500(7031)
Standard Materials for Fluid End Bodies
Cast Steel

18.88
TYP

17.00
12.00

8.00
TYP

24.00

34.00

43.25

1.50
TYP
6 PLACES

4.250
4.249

13.00
BY-PASS

1.00 X 1.50 KEYWAY


16.00 LONG

DISCHARGE
CONNECTION

BY-PASS
CONNECTION
16.25
ROTATION
DIRECTION

F
52.00

45.75

39.81

B
23.50

3.50
TYP

37.88

10.00
TYP

33.62

SUCTION
CONNECTION
3 PLACES

13.00
SUCTION
61.75

Pump Model
2652

Flange Connections

Dimensions (Inches)

Discharge Connection Sizes

Suction Connection Sizes

By-Pass Connection Sizes

4 (101.6)-600# ANSI FF

8 (203.2)-300# ANSI FF

2 (50.8)-600# ANSI FF

14 3/4

49 1/2

86 1/4

131 9/16

19 1/8

2652 Duplex Double-Acting Piston Pump


Performance Data
PUMP

2652

PUMP

2652

English Units
Piston
Piston
BPD
Dia.
Area
per
In.
Sq. In.
RPM
4.000
12.5664
78.3840
4.500
15.9043
102.096
5.000
19.6349
128.712
5.500
23.7583
158.064
6.000
28.2743
190.296
6.500
33.1830
225.120
7.000
38.4845
262.968
7.250
41.2825
283.272
Brake Horsepower Required

GPM
per
RPM
2.2862
2.9778
3.7541
4.6102
5.5503
6.5660
7.6699
8.2621

Max.
Press.
PSI
1125
1125
1125
930
782
666
574
535

Metric Units
Plunger
Plunger
Dia.
Area
mm
cm2
102
81.073
114
102.608
127
126.677
140
153.279
152
182.415
165
214.084
178
248.286
184
266.338
Kilowatts Required

L/Sec.
per
RPM
0.1442
0.1879
0.2368
0.2909
0.3502
0.4142
0.4839
0.5213

25 RPM
40 RPM
Max.
Press.
kPa M3/Hr L/Sec. M3/Hr L/Sec.
7757
13.0
3.6
20.8
5.8
7757
16.9
4.7
27.1
7.5
7757
21.3
5.9
34.1
9.5
6414
26.2
7.3
41.9
11.6
5389
31.5
8.8
50.4
14.0
4592
37.3
10.4
59.6
16.6
3959
43.5
12.1
69.7
19.4
3691
46.9
13.0
75.1
20.9
57
91

M3/Hr
per
RPM
0.5192
0.6763
0.8526
1.0470
1.2605
1.4911
1.7418
1.8763

25 RPM

BPD
1960
2553
3218
3952
4758
5628
6575
7082

GPM
57.2
74.4
93.9
115.3
138.8
164.2
191.7
206.6
76

40 RPM

BPD GPM
3136
91.4
4084
119.1
5149
150.2
6323
184.4
7612
222.0
9005
262.6
10519 306.8
11331 330.5
121

55 RPM

BPD
4312
5616
7080
8694
10467
12382
14464
15580

GPM
125.7
163.8
206.5
253.6
305.3
361.1
421.8
454.4
167

55 RPM

M3/Hr
28.6
37.2
46.9
57.6
69.3
82.0
95.8
103.2

L/Sec.
7.9
10.3
13.0
16.0
19.3
22.8
26.6
28.7
125

70 RPM

BPD
5487
7147
9010
11065
13321
15759
18408
19830

GPM
160.0
208.4
262.8
322.7
388.5
459.6
536.9
578.3
213

70 RPM

M3/Hr
36.3
47.3
59.7
73.3
88.2
104.4
121.9
131.3

85 RPM

BPD
6663
8679
10941
13436
16176
19136
22353
24079

GPM
194.3
253.1
319.1
391.9
471.8
558.1
651.9
702.3
258

85 RPM

L/Sec. M3/Hr L/Sec.


10.1
44.1
12.3
13.2
57.5
16.0
16.6
72.5
20.1
20.4
89.0
24.7
24.5
107.1
29.8
29.0
126.7
35.2
33.9
148.1
41.1
36.5
159.5
44.3
158
192

RPM shown is Crankshaft speed. For Pinion Shaft speed, multiply RPM by Gear Ratio. Volumetric Rate is based on 100% Volumetric Efficiency. Brake Horsepower/Kilowatts Required
is based on 85% Mechanical Efficiency.
The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own
evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that
stipulated in National Oilwell Standard Terms and Conditions of Sale.

Authorized Distributor:

www.natoil.com / customer.service@natoil.com
10000 Richmond, Houston, Texas 77042
(713)346-7500 (phone) (713)346-7366 (fax)

JWS-185 Triplex Well Service Pump


15 5/8
3.000
2.999

DIA

Specifications

DIA

3/4 "X 3/8 " KEYWAY

SUCTION AND DISCHARGE


CONNECTIONS MAY BE
MADE AT EITHER END

8 1/8

9 7/16

6 3/16

4.125
4.123

36" SUCTION

27" DISCHARGE

13 1/8

7 1/2

51 7/8

7 1/2

26 1/4

26 15/16

1" x 1/2 " KEYWAY

5 7/8

1 1/8 " DIA HOLES


4 PLACES AS SHOWN
1" x 1/2 " KEYWAY
4.125
4.123

SHAFT EXTENSION
FOR DIRECT DRIVE

DIA
48 3/4

14 1/2
36 1/2

2 1/16 " API-10,000#


RING JOINT FLANGE

1 1/2 " STD PIPE TAP


CRADLE DRAIN, BOTH SIDES

24 15/16

29

6 3/16

CENTERLINE
DISCHARGE

9 3/4
1 1/2 " STD PIPE TAP
MUD TRAP DRAIN

3 3/4

7 3/4

2" STD PIPE TAP


CRADLE DRAIN

19 3/4
40 3/4
67 1/4

1" STD PIPE TAP


POWER END OIL DRAIN

Pump Model
JWS-185

Flange Connections
Discharge Connection Sizes
Suction Connection Sizes
2 1/16 API 10,000# RJ
6 STD Pipe

SUCTION
6" SCH. 40
BFW PIPE

13 1/16

6"

10

CENTERLINE
SUCTION

2 1/4

12 1/4

2 1/4

Pump Size
max. plunger dia. x stroke) in.(mm):
4 x 5 (102 x 127)
Rated bhp at 450 rpm (kw): 185 (137.9)
Maximum pressure: psi(kPa):
10,000 (68,950)
Stroke Length in.(mm): 5 (127)
Max. Speed rpm: 450
Max. plunger in.(mm): 4 (101.6)
Max. piston in.(mm): 41/2 (114.3)
Crankshaft extension: in.(mm)
Diameter: 4 1/8 (104.78)
Length: 8 1/8 (206.38)
Keyway (width x depth):
1 x 1/2 (25.4 x 12.7)
Pinion shaft extension,
if gear unit supplied in.(mm)
For Belt or chain drive:
Diameter: 3 (76.2)
Length: 6 3/16 (157.16)
Keyway (width x depth):
3/4 x 3/8 (19.05 x 9.53)
For direct drive:
Diameter: 3 (76.2)
Length: 6 3/16 (157.16)
Keyway (width x depth):
3/4 x 3/8 (19.05 x 9.53)
Accessory Gear Units:
See accessories for reduction ratios.
Oil Capacity: gallons (L)
Crankcase: 8 (30)
Gear unit - Varies with gear ratio:
2.25 to 3.5 (8.52 to 13.25)
Weight, Pump only on
wood shipping skids, pounds(Kg):
4000 (1814)
Gear unit, approximate, pounds(Kg):
800 (363)
Standard Equipment:
Forged steel fluid end
Forged steel valve covers
Piston & liners or plungers & packing
Slush type valves
Oil level dipstick
Crankcase breather
Stainless steel extension rods
Double extended crankshaft
Accessories:
Gear reduction units:
3.22:1, 3.46:1, 4.38:1, 4.96:1
Suction stabilizer
Discharge dampener
Liner flush system
Plunger lubricator
Valve seat puller assembly
Complete unitization with
electric motor or engine drive

JWS-185 Triplex Well Service Pump


Performance Data
Diameter, in.
gal/min. per RPM
bbl/min. per RPM
Reqd.
RPM
hp
450
185
400
185
350
185
300
185
250
185
225
185
200
185
100
132
50
66
25
33

Plungers Only
2
.2040
.0049
gal/
bbl/
PSI
min.
min.
3110
92
2.19
3500
82
1.94
4000
71
1.70
4660
61
1.46
5600
51
1.21
6220
46
1.09
7000
41
0.97
10000
20
0.49
10000
10
0.24
10000
5
0.12

PSI
1644
1850
2110
2470
2960
3290
3700
5250
5250
5250

2 3/4
.3857
.0092
gal/
min.
174
154
135
116
96
87
77
39
19
10

bbl/
min.
4.13
3.67
3.21
2.75
2.30
2.07
1.84
0.92
0.46
0.23

PSI
1020
1140
1310
1520
1830
2030
2280
3240
3240
3240

3 1/2
.6247
.0149
gal/
min.
281
250
219
187
156
141
125
62
31
16

bbl/
min.
6.69
5.95
5.21
4.46
3.72
3.35
2.97
1.49
0.74
0.37

PSI
780
870
1000
1170
1400
1550
1750
2480
2480
2480

4
.8160
.0194
gal/
min.
367
326
286
245
204
184
163
82
41
20

bbl/
min.
8.74
7.77
6.80
5.83
4.86
4.37
3.89
1.94
0.97
0.49

Pistons Only
4 1/2
1.0327
.0246
gal/
bbl/
PSI
min.
min.

1230
1380
1960
1960
1960

232
207
103
52
26

5.53
4.92
2.46
1.23
0.61

(Volumes indicated are displacement of incompressable fluid)


The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own
evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that
stipulated in National Oilwell Standard Terms and Conditions of Sale.

Authorized Distributor:

www.natoil.com / customer.service@natoil.com
10000 Richmond, Houston, Texas 77042
(713)346-7500 (phone) (713)346-7366 (fax)

JWS-340 Triplex Well Service Pump


Specifications

7/8 "x 7/16 KEYWAY


5 11/16
9 1/4

3.500
3.499

DIA.

11 1/8

4.875
DIA.
4.873

30 5/8

1 1/4 "x 5/8 " KEYWAY

36" SUCTION

7 1/2

27" DISCHARGE

7 1/2

55 1/2

13 1/8

13 1/8

6
7
1 1/8 " DIA. HOLE THRU

5 5/8

1 1/4 " x 5/8 " KEYWAY

SHAFT EXTENSION

4.875
4.873

16 3/4

48 3/4

1" STD. PIPE TAP

3 3/4

7 3/4

2" STD. PIPE TAP

19 3/4
40 3/4
67 1/4

Pump Model
JWS-340

24 15/16
9 3/4

1 1/2 " STD. PIPE TAP

3 3/4

Flange Connections
Discharge Connection Sizes
Suction Connection Sizes
2 1/16 API 10,000# RJ
6 STD Pipe

13 1/16

6"

2 1/4

9"

12 1/4

7"

31 1/4

22 7/8

6 3/16

36 1/2

Pump size
max. plunger dia. X stroke) in.(mm):
4 x 5 (102 x 127)
Rated bhp at 450 rpm (kw): 340 (253.5)
Maximum pressure: psi (kPa):
10,000(68,950)
Stroke length in. (mm): 5 (127)
Max. speed rpm: 450
Max. plunger in.(mm): 4 (101.6)
Max. piston in.(mm): 4 1/2 (114.3)
Crankshaft extension: in. (mm)
Diameter: 4 7/8 (123.8)
Length: 11 3/4 (298.0)
Keyway (width x depth):
1 1/4 x 5/8 (32.0 x 16.0)
Pinion shaft extension,
if gear unit supplied in.(mm)
For belt or chain drive:
Diameter: 3 1/2 (88.9)
Length: 5 11/16 (144)
Keyway (width x depth):
7/8 x 7/16 (22.2 x 11.1)
For direct drive:
Diameter: 3 1/2 (88.9)
Length: 5 11/16 (144)
Keyway (width x depth):
7/8 x 7/16 (22.2 x 11.1)
Accessory gear units:
See accessories for reduction ratios
Oil capacity: gallons(L)
Crankcase: 6 (22.7)
Gear Unit Varies with gear ratio:
3.5 to 6.5 (13.2 to 24.6)
Weight, pump only on
wood shipping skids pounds (Kg):
5200 (2359)
Gear unit, approximate pounds (Kg):
1100 (499)
Standard Equipment
Forged steel fluid end
Forged steel valve covers
Piston & liners or plungers & packing
Slush type valves
Oil level dipstick
Crankcase breather
Stainless steel extension rods
Double extended crankshaft
Accessories
Gear Reducers
2.27:1, 2.89:1, 3.25:1, 4.38:1, 4.84:1, 5.63:1
Suction stabilizer
Discharge dampener
Liner flush system
Plunger lubricator
Valve seat puller assembly
Complete unitization with
electric motor or engine drive

JWS-340 Triplex Well Service Pump


Performance Data
Diameter, in.
gal/min. per RPM
bbl/min. per RPM
Reqd.
RPM
hp
450
340
400
340
350
340
300
340
250
340
225
340
200
340
100
252
50
126
25
63

PSI
3020
3400
3890
4530
5440
6040
6800
10000
10000
10000

23/4
.3857
.0092
gal/
min.
174
154
135
116
96
87
77
39
19
10

bbl/
min.
4.13
3.67
3.21
2.75
2.30
2.07
1.84
.92
.46
.23

PSI
1870
2100
2400
2800
3360
3730
4200
6220
6220
6220

31/2
.6247
.0149
gal/
min.
281
250
219
187
156
141
125
62
31
16

bbl/
min.
6.69
5.95
5.21
4.46
3.72
3.35
2.97
1.49
.74
.37

PSI
1430
1610
1840
2140
2570
2860
3210
4760
4760
4760

4
.8160
.0194
gal/
min.
367
326
286
245
204
184
163
82
41
20

bbl/
min.
8.74
7.77
6.80
5.83
4.86
4.37
3.89
1.94
.97
.49

PSI
2260
2540
3760
3760
3760

Pistons Only
41/2
1.0327
.0246
gal/
bbl/
min.
min.
232
5.53
207
4.92
103
2.46
52
1.23
26
.61

(Volumes indicated are displacement of incompressable fluid)


The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own
evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that
stipulated in National Oilwell Standard Terms and Conditions of Sale.

Authorized Distributor:

www.natoil.com / customer.service@natoil.com
10000 Richmond, Houston, Texas 77042
(713)346-7500 (phone) (713)346-7366 (fax)

W-350 Triplex Plunger Pump


P.E. LUBRICATION
1" FNPT (BOTH SIDES)

DISCHARGE CONNECTION
2" - 1502 WECO OR
3" - 1502 WECO

2" NPT SUMP


CONNECTION
TYP 2 PLACES

ROTARY UNION
1/2" NPT

Pump Type
Horizontal Reciprocating Power Pump. Positive
Displacement with Single-Acting Plungers
Maximum Input Horsepower:
350 Intermittent, 200 Continuous
Stroke Length: 6 inches
Maximum Rod Load: 80,000 Ibs.
Approximate Weight: 4,500 Ibs.
Pump Power End: Fabricated of High
Strength Steel
Gears: Helical External Gearbox
Gear Ratio: 5.25:1 or 4.68:1
Rod Bearings: Shell Type Replaceable
Main Bearings: Straight Roller
Pinion Bearings: Tapered Roller
Crankshaft: One Piece Forged Alloy Steel
Connecting Rod: Cast Steel
Crosshead Guide: Cast Iron
Fluid End:
Plunger Type Monoblock Design. Machined
From High Strength Alloy Steel, Heat Treated
and Ultrasonic Tested - Auto
Plunger Diameter: 2 to 5 inches
Discharge Outlet: 2-inch WECO Union
Suction Inlet: 4 or 6-inch Standard Pipe
Valves and Seats:
Hardened Steel, Replaceable Insert
Power End Lubrication:
18 GPM Required, Optional Hydraulic Lubrication
System w/ Sump Available
Packing Lubrication: Optional Air Driven Air/Oil
or Mechanical Oil Drip System Available

25.16

.69

20.28

3.75
TYP

31.72

1" NPT
PIPE PLUG

BLIND FLANGE

1810 SERIES SPICER


COMPANION FLANGE

55.88

A
B
C

16.00

PUMP
ROTATION
GEARBOX

28.87

ROTATION

WECO is a registered trademark of FMC

13.25
F
4.66
G

1.63
2.38

VICTAULIC CONNECTION

2.50

TYP BOTH SIDES

1" NPT SUMP CONNECTION


TYP BOTH SIDES
38.00

Pump Model

1.63

Flange Connections
Discharge Connection Sizes
Suction Connection Sizes
2 (50.8) 1502 Half Union
4 (101.6) Grooved Pipe
3 (76.2) 1502 (Optional)
6 (152.4) Optional

W-350

Specifications

Dimensions (Inches)
FE Size

3 1/2 - 4

4 1/8

6 1/4

3 1/8

9 9/32

6 1/8

12 3/8

5 3/4

25 5/8

18 11/16

15 1/16

11

4 1/2 - 5

4 1/2

5 7/8

2 3/4

10 13/16

13 1/4

5 3/4

27

18 1/4

15 13/16

11 1/4

W-350 Triplex Plunger Pump


Performance Data
Displacement
Plunger
Factors*
Diameter
@ 100% V. E.
U.S. Gal.
per Rev.
Inches
GPR
5.00
1.530
4.50
1.239
4.00
0.979
3.50
0.750
3.00
0.551
2.75
0.463
2.50
0.382
2.25
0.310
2.00
0.245
Input
Brake **
Power
Horsepower
Pinion RPM
@ 5.25:1 Gear Ratio
Pinion RPM
@ 4.68:1 Gear Ratio

50
Flow
@ 100% V. E.
U.S. Gal.
per Min.
GPM
77
62
49
38
28
23
19
16
12

Max
Press.
@ Flow
PSIG
4076
5033
6369
8314
11317
13468
16323
20115
25451

Pump Speed in Crankshaft Revolutions Per Minute (RPM)


100
200
300
Flow
Max
Flow
Max
Flow
@ 100% V. E.
Press.
@ 100% V. E.
Press.
@ 100% V. E.
U.S. Gal.
@ Flow
U.S. Gal.
@ Flow
U.S. Gal.
per Min.
per Min.
per Min.
GPM
PSIG
GPM
PSIG
GPM
153
3333
306
1666
459
124
4116
248
2058
372
98
5209
196
2604
294
75
6799
150
3399
225
55
9254
110
4627
165
46
11013
93
5507
139
38
13349
76
6674
115
31
16449
62
8224
93
25
20813
49
10406
74

Max
Press.
@ Flow
PSIG
1111
1372
1736
2266
3085
3671
4450
5483
6938

450
Flow
@ 100% V. E.
U.S. Gal.
per Min.
GPM
689
558
441
338
248
208
172
140
110

214

350

350

350

350

263

525

1050

1575

2363

234

468

936

1404

2106

Max
Press.
@ Flow
PSIG
741
915
1157
1500
2050
2450
2960
4600
4625

*V.E. = Volumetric Efficiency, ** BHP (Brake Horsepower) is based on 85% Mechanical Efficiency
The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own
evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that
stipulated in National Oilwell Standard Terms and Conditions of Sale.

Authorized Distributor:

www.natoil.com / customer.service@natoil.com
10000 Richmond, Houston, Texas 77042
(713)346-7500 (phone) (713)346-7366 (fax)

JWS-400 Triplex Well Service Pump


1 1/2 " x 3/4 " KEYWAY

5.998
6.000

DIA.

Specifications
SUCTION & DISCHARGE CONNECTIONS
MAY BE MADE AT EITHER END

10 1/4 " (USABLE SHAFT EXT.)

40 3/4 DISCHARGE

48 SUCTION

14 3/8

79 11/16

14 3/8

20 3/4

39 27/32

20 3/4

8
6 1/2

4 7/8
6.000
5.998

DIA.

10 1/4 " (USABLE SHAFT EXT.)

1 1/2 " DIA. HOLE THRU


4 PLACES, AS SHOWN

1 1/2 " x 3/4 " KEYWAY


DISCHARGE
3 1/16 API 10,000# R.J.
DISCHARGE
CENTERLINE
6"

8 1/2

16 5/16

13 5/8

1 1/4

1 1/2"NPT(1 EACH SIDE)


15 1/2

28 13/16

2 1/4

SUCTION
CENTERLINE
61 7/8
1 3/4

15 1/8

SUCTION
6" ANSI 150# F.F.
51 5/8
66 1/8
89

1" NPT (POWER END OIL DRAIN)

Pump Model
JWS-400

2" NPT (CRADLE DRAIN)

Flange Connections
Discharge Connection Sizes
Suction Connection Sizes
3 1/16 API 6 BX 10,000 PSI
6 ASA-150# RF

Pump size (max. liner dia. X stroke) in. (mm):


5 1/2 x 7 (139.7 x 177.8)
Pump size (max. plunger dia. X stroke) in. (mm):
4 1/2 x 7 (114.3 x 177.8)
Rated bhp at 286 rpm (kw): 400 (298)
Maximum working pressure: psi (kPa):
10,000 (68,950)
Stroke length, in. (mm): 7 (177.8)
Max. speed rpm: 286
Max. plunger in.(mm): 4 1/2 (114.3)
Max. piston in.(mm): 5 1/2 (139.7)
Crankshaft extension: in. (mm)
Diameter: 6 (152.4)
Length: 10 1/4 (260.4)
Keyway (width x depth):
1 1/2 x 3/4 (38.1 x 19.05)
Pinion shaft extension,
if chain drive supplied in. (mm)
Diameter: 3.75 (95.25)
Length: 6 (152.4)
Keyway (width x depth):
7/8 x 7/16 (22.2 x 11.1)
Accessory gear units:
See accessories for reduction ratios
Oil Capacity: gallons (L)
Crankcase: 22 (83.3)
Chaincase : 30 (113.5)
Weight, pump with reducer pounds (Kg):
15,000 (6804)
Standard Equipment
Forged steel fluid end
Forged steel valve covers
Piston & liners or plungers & packing
Slush type valves
Oil level dipstick
Crankcase breather
Stainless steel extension rods
Double extended crankshaft
Accessories
Chain reducer (4.667:1)
Suction stabilizer
Discharge dampener
Liner flush system
Plunger lubricator
Valve seat puller assembly
Complete unitization with electric motor or
engine drive

JWS-400 Triplex Well Service Pump


Performance Data
Diameter, in.
gal/min. per RPM
bbl/min. per RPM
Reqd.
RPM
hp
286
400
250
400
200
400
175
400
140
400
100
400
75
400
55
400
25
187

4
1.142
.02719
gal/
PSI
min.
1900
327
2175
286
2725
228
3100
200
3819
160
5445
114
7250
86
10,000
63
10,000
29

bbl/
min.
7.78
6.80
5.44
4.76
3.80
2.72
2.04
1.50
.68

PSI
1500
1715
2140
2435
3072
4280
5747
8000
8000

41/2
1.446
.0344
gal/
min.
414
361
289
253
202
145
108
80
36

bbl/
min.
9.85
8.61
6.88
6.02
4.82
3.44
2.58
1.89
.86

Pistons Only
5
1.785
.0425
gal/
bbl/
PSI
min.
min.
1217
510
12.1
1390
446
10.6
1741
357
8.5
1979
312
7.43
2483
250
5.95
3482
178
4.24
4636
134
3.19
6334
98
2.33
6400
45
1.07

Pistons Only
51/4
1.968
.0469
gal/
bbl/
PSI
min.
min.
1102
563
13.4
1261
492
11.7
1579
394
9.38
1795
344
8.19
2249
276
6.57
3159
197
4.69
4205
148
3.52
5747
108
2.57
5804
49
1.17

PSI
1004
1149
1439
1635
2055
2878
3831
5216
5289

Pistons Only
51/2
2.159
.0514
gal/
bbl/
min.
min.
618
14.7
540
12.8
432
10.3
378
9.0
302
7.19
216
5.14
162
3.86
119
2.83
54
1.28

(Volumes indicated are displacement of incompressable fluid)


The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own
evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that
stipulated in National Oilwell Standard Terms and Conditions of Sale.

Authorized Distributor:

www.natoil.com / customer.service@natoil.com
10000 Richmond, Houston, Texas 77042
(713)346-7500 (phone) (713)346-7366 (fax)

W-500 Triplex Plunger Pump


ROTARY UNION
1/2" NPT

P.E. LUBRICATION
1" FNPT (BOTH SIDES)

DISCHARGE CONNECTION
2" - 1502 WECO OR
3" - 1502 WECO

2" NPT SUMP


CONNECTION
TYP 2 PLACES

Pump Type:
Horizontal Reciprocating Power Pump. Positive
Displacement with Single-Acting Plungers
Maximum Input Horsepower:
500 Intermittent, 250 Continuous
Stroke Length: 6 inches
Maximum Rod Load: 100,000 Ibs.
Approximate Weight: 5,000 Ibs.
Pump Power End: Fabricated of High Strength Steel
Gears: Helical, External Gearbox
Gear Ratio: 4.68:1
Rod Bearings: Shell Type Replaceable
Main Bearings: Straight Roller
Pinion Bearings: Tapered Roller
Crankshaft: One Piece Forged Alloy Steel
Connecting Rod: Cast Steel
Crosshead Guide: Cast Iron
Fluid End:
Plunger Type Monoblock Design. Machined From
High Strength Alloy Steel, Heat Treated and
Ultrasonic Tested
Plunger Diameter: 2.25 to 5 inches
Discharge Outlet: 2-inch WECO Type Union
Suction Inlet: 4 or 6-inch Standard Pipe
Valves and Seats:
Hardened Steel, Replaceable Inserts
Power End Lubrication:
18 GPM Required, Optional Hydraulic Lubrication
System w/ Sump Available
Packing Lubrication: Optional Air Driven Air/Oil or
Mechanical Oil Drip System Available

25.16

.69

22.03

3.75
TYP

33.47

1" NPT
PIPE PLUG

BLIND FLANGE

1810 SERIES SPICER


COMPANION FLANGE

55.88

A
B
C

16.00

PUMP
ROTATION
GEARBOX

28.87

ROTATION

13.25
F
4.66
G

1.63

VICTAULIC CONNECTION

2.38

2.50

TYP BOTH SIDES


1" NPT SUMP CONNECTION
TYP BOTH SIDES
38.00

Pump Model

1.63

Flange Connections
Discharge Connection Sizes
Suction Connection Sizes
2 (50.8) 1502 Half Union
4 (101.6) Grooved Pipe
3 (76.2) 1502 (Optional)
6 (152.4) Optional

W-500

Dimensions (Inches)
FE Size

2 3/4 - 3

4 1/2

5 1/2

2 3/8

8 3/4

5 3/8

11 1/4

4 3/4

27 1/2

3 1/2 - 4

4 1/8

6 1/4

3 1/8

9 9/32

6 1/8

12 3/8

4 3/4

27 5/8

4 1/2 - 5

4 3/8

3 1/32

10 13/16

13 1/4

4 3/4

29

Specifications

W-500 Triplex Plunger Pump


Performance Data
Displacement
Plunger
Factors*
Diameter @ 100% V. E.
U.S. Gal.
per Rev.
Inches
GPR
5.00
1.530
4.50
1.239
4.00
0.979
3.50
0.750
3.00
0.551
2.75
0.463
2.50
0.382
2.25
0.310
Input
Brake**
Power
Horsepower
Pinion RPM
@4.68:1 Gear Ratio

50
Flow
@ 100% V. E.
U.S. Gal.
per Min.
GPM
77
62
49
38
28
23
19
16
267
234

Max
Press.
@ Flow
PSIG
5085
6279
7947
10373
14120
16803
20366
25096

Pump Speed in Crankshaft Revolutions Per Minute (RPM)


100
200
300
Flow
Max
Flow
Max
Flow
@ 100% V. E.
Press.
@ 100% V. E.
Press.
@ 100% V. E.
U.S. Gal.
@ Flow
U.S. Gal.
@ Flow
U.S. Gal.
per Min.
per Min.
per Min.
GPM
PSIG
GPM
PSIG
GPM
153
4761
306
2381
459
124
5879
248
2940
372
98
7441
196
3720
294
75
9713
150
4856
225
55
13221
110
6610
165
46
15733
93
7867
139
38
19069
76
9535
115
31
23498
62
11749
93
500
500
500
468

936

1404

Max
Press.
@ Flow
PSIG
1587
1960
2480
3238
4407
5244
6356
7833

450
Flow
@ 100% V. E.
U.S. Gal.
per Min.
GPM
689
558
441
338
248
208
172
140
500

Max
Press.
@ Flow
PSIG
1058
1307
1654
2158
2900
3496
4238
5222

2106

*V.E. = Volumetric Efficiency **BHP (Brake Horsepower) is based on 85% Mechanical Efficiency
The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own
evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that
stipulated in National Oilwell Standard Terms and Conditions of Sale.

Authorized Distributor:

www.natoil.com / customer.service@natoil.com
10000 Richmond, Houston, Texas 77042
(713)346-7500 (phone) (713)346-7366 (fax)

W-600S Plunger Pump


Specifications
Pump type:
Intermittent duty reciprocating pump
Maximum Input Horsepower: 600 Intermittent
Stroke Length: 6 inches
Maximum Rod Load: 100,000 lbs.
Approximate Weight: 4,600 lbs.
Pump Power End:
Fabricated of high strength alloy steel
Gears: Helical
Gear Ratio: 4.6:1
Rod Bearings: Shell type replaceable
Main Bearings: Straight roller
Gearbox Bearings: Tapered roller
Crankshaft: One-piece forged alloy steel nitrided
Connecting Rod: Cast steel
Crosshead: Cast steel
Crosshead Slide:
Shim adjustable, replaceable cast iron
Fluid-End: Plunger type mono-block design
Discharge: 2 inch half union forged
steel female connection both ends
Suction: Fabricated steel with
4 grooved connections both ends
Valves and Seats: Service Master II

53.70

33.14

50.46

1.50
6.88

23.82

12.00

11.00

2.50

32.32

Pump Model
W600-S

Flange Connections
Discharge Connection Sizes
Suction Connection Sizes
2 (50.8) 1502 Half Union
4 (101.6) Grooved Pipe

W-600S Plunger Pump


Performance Data
Displacement
Plunger
Factors*
Diameter @ 100% V. E.
U.S. Gal.
per Rev.
Inches
GPR
2.50
.3825
2.75
.4628
3.00
.5508
3.50
.7497
4.00
.9792
4.50
1.2393
Input
Brake**
Power
Horsepower
Pinion RPM
@4.60:1 Gear Ratio

50
Flow
@ 100% V. E.
U.S. Gal.
per Min.
GPM
19.12
23.14
27.54
37.48
48.96
61.96
253
230

Max
Press.
@ Flow
PSIG
20372
16836
14147
10394
7958
6288

Pump Speed in Crankshaft Revolutions Per Minute (RPM)


120
200
300
Flow
Max
Flow
Max
Flow
@ 100% V. E.
Press.
@ 100% V. E.
Press.
@ 100% V. E.
U.S. Gal.
@ Flow
U.S. Gal.
@ Flow
U.S. Gal.
per Min.
per Min.
per Min.
GPM
PSIG
GPM
PSIG
GPM
45.90
20165
76.50
12099
114.75
55.54
16665
92.56
9999
138.85
66.10
14003
110.16
8402
165.24
89.96
10288
149.94
6173
224.91
117.50
7877
195.84
4726
293.76
148.72
6224
247.86
3734
371.79
600
600
600
552

920

1380

Max
Press.
@ Flow
PSIG
8066
6666
5601
4115
3151
2489

450
Flow
@ 100% V. E.
U.S. Gal.
per Min.
GPM
172.12
208.27
247.86
337.36
440.64
557.68
600

Max
Press.
@ Flow
PSIG
5377
4444
3734
2744
2100
1660

2070

*V.E. = Volumetric Efficiency **BHP (Brake Horsepower) is based on 90% Mechanical Efficiency
The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own
evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that
stipulated in National Oilwell Standard Terms and Conditions of Sale.

Authorized Distributor:

www.natoil.com / customer.service@natoil.com
10000 Richmond, Houston, Texas 77042
(713)346-7500 (phone) (713)346-7366 (fax)

W-1300 Triplex Plunger Pump


Specifications

DISCHARGE CONNECTION
MAY BE MOUNTED ON
EITHER SIDE OF PUMP

7.50

22.69

52.63

37.63

66.11

BLIND FLANGE
1/4 NPT LUBRICATION
CONN. FOR STUFFING BOX

6.82

7.26

4.00 PINION
KEYWAY IS
1.0 WIDE x .5 DP

40.38

34.51

22.50
19.06

E
44.42

Pump Type:
Horizontal Reciprocating Power Pump Positive
Displacement with Single-Acting Plungers
Maximum Input Horsepower:
1,300 Intermittent, 650 Continuous
Stroke Length: 8 inches
Maximum Rod Load: 200,000 Ibs.
Approximate Weight: 11,000 Ibs.
Pump Power End: Fabricated of High Strength Steel
Gears: Double Helical
Gear Ratio: 7.0:1 or 7.5:1
Rod Bearings: Shell Type Replaceable
Main Bearings: Straight Roller
Pinion Bearings: Spherical Roller
Crankshaft: One Piece Forged Alloy Steel
Connecting Rod: One Piece Forged Steel
with Knuckle Joint
Crosshead Guide: Bronze Replaceable
Fluid End:
Plunger Type Monoblock Design. Machined From
High Strength Alloy Steel, Heat Treated and
Ultrasonic Tested
Autofrettaged*
Plunger Diameter: 3.75 to 7.5 inches
Discharge Outlet: 2 or 3-inch WECO Union
Suction Inlet: 6 or 8-inch Diameter
Valves and Seats: Hardened Steel, Replaceable Insert
Power End Lubrication:
35 GPM Required, Optional Hydraulic Lubrication
System w/ Removable Bolt on Sump
Packing Lubrication: Optional Air Driven Air/Oil or
Mechanical Oil Drip System Available

11.00
F

WECO is a registered trademark of FMC


*Autofrettaged Fluid Ends available for 5 3/4
& smaller Plungers
11.81
G

17.50

8.50

1" NPT CONNECTION

55.50

89.88

Pump Model
W-1300

Flange Connections
Discharge Connection Sizes
Suction Connection Sizes
2 (50.8) 1502 Half Union
4 (101.6) Grooved Pipe
3 (76.2) 1502 (Optional)
6 (152.4) Optional

Dimensions (Inches)
FE Size

24 3/4

8 1/8

3 1/4

11 9/64

7 1/8

14 1/16

8 3/4

4 1/2

24 3/4

8 1/8

3 1/2

11 9/64

7 1/8

14 1/16

8 3/4

24 3/4

8 1/8

3 1/2

11 9/64

7 1/8

14 1/16

8 3/4

5 1/2

24 3/4

7 1/8

11 1/2

7 5/8

15 3/16

7 5/8

5 3/4

24 3/4

7 1/8

11 1/2

7 5/8

15 3/16

7 5/8

6 1/2

25

7 1/8

11 1/2

8 1/2

15 11/16

7 1/8

6 3/4

25

7 1/8

11 1/2

8 1/2

15 11/16

7 1/8

W-1300 Triplex Plunger Pump


Performance Data
Displacement
Plunger
Factors*
Diameter
@ 100% V. E.
U.S. Gal.
per Rev.
Inches
GPR
7.50
4.590
7.00
3.999
6.75
3.713
6.50
3.448
6.00
2.938
5.75
2.698
5.50
2.468
5.00
2.040
4.50
1.652
4.00
1.306
3.75
1.147
Input
Brake**
Power
Horsepower
Pinion RPM
@7.50:1 Gear Ratio
Pinion RPM
@ 7.00:1 Gear Ratio

100
Flow
@ 100% V. E.
U.S. Gal.
per Min.
GPM
459
400
371
345
294
270
247
204
165
131
115

Max
Press.
@ Flow
PSIG
4126
4736
5101
5493
6446
7020
7670
9284
11465
14502
16512 ***

Pump Speed in Crankshaft Revolutions Per Minute (RPM)


150
200
250
Flow
Max
Flow
Max
Flow
Max
@ 100% V. E.
Press.
@ 100% V. E.
Press.
@ 100% V. E.
Press.
U.S. Gal.
@ Flow
U.S. Gal.
@ Flow
U.S. Gal.
@ Flow
per Min.
per Min.
per Min.
GPM
PSIG
GPM
PSIG
GPM
PSIG
689
2715
918
2063
1148
1651
600
3157
800
2368
1000
1849
557
3401
743
2550
928
2040
517
3662
690
2746
862
2197
441
4298
588
3223
735
2579
405
4680
540
3510
675
2808
370
5120
494
3830
617
3070
306
6189
408
4642
510
3714
248
7643
330
5732
413
4586
196
9668
261
7251
327
5801
172
11008
229
8256
287
6605

330
Flow
@ 100% V. E.
U.S. Gal.
per Min.
GPM
1515
1320
1225
1138
970
890
814
673
545
431
379

1300

1300

1300

1300

1300

750

1125

1500

1875

2475

700

1050

1400

1750

2310

Max
Press.
@ Flow
PSIG
1250
1435
1546
1665
1953
2127
2330
2813
3474
4395
5004

* V.E. = VOLUMETRIC EFFICIENCY, **BHP (Brake Horsepower) is based on 85% Mechanical Efficiency *** Applications at pressures above 15,000 PSIG must be approved by OMEGA Engineering Department
The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own
evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that
stipulated in National Oilwell Standard Terms and Conditions of Sale.

Authorized Distributor:

www.natoil.com / customer.service@natoil.com
10000 Richmond, Houston, Texas 77042
(713)346-7500 (phone) (713)346-7366 (fax)

W-2250 Triplex Plunger Pump


Specifications

DISCHARGE CONNECTION
MAY BE MOUNTED ON
EITHER SIDE OF PUMP

7.50

22.69

52.63

37.63

65.60

BLIND FLANGE
1/4 NPT LUBRICATION
CONN. FOR STUFFING BOX

6.75

6.06

29 TOOTH EXTERNAL

40.38

SPLINE, 3.750

34.51

22.50
19.06

E
44.42
11.00
F

11.81
G

17.50

8.50

1" NPT CONNECTION

55.50

89.88

Pump Model
W-2250

Flange Connections
Discharge Connection Sizes
Suction Connection Sizes
2 (50.8) 1502 Half Union
4 (101.6) Grooved Pipe
3 (76.2) 1502 (Optional)
6 (152.4) Optional

Dimensions (Inches)
FE Size

24 3/4

8 1/8

3 1/4

11 9/64

7 1/8

14 1/16

8 3/4

4 1/2

24 3/4

8 1/8

3 1/2

11 9/64

7 1/8

14 1/16

8 3/4

24 3/4

8 1/8

3 1/2

11 9/64

7 1/8

14 1/16

8 3/4

5 1/2

24 3/4

7 1/8

11 1/2

7 5/8

15 3/16

7 5/8

5 3/4

24 3/4

7 1/8

11 1/2

7 5/8

15 3/16

7 5/8

6 1/2

25

7 7/8

11 1/2

8 1/2

15 11/16

7 1/8

6 3/4

25

7 7/8

11 1/2

8 1/2

15 11/16

7 1/8

Pump Type:
Intermittent duty reciprocating pump
Maximum Input Horsepower: 2250 Intermittent
Stroke Length: 8 inches
Maximum Rod Load: 250,000 lbs.
Approximate Weight: 11,500 lbs.
Pump Power End:
Fabricated of high-strength alloy steel
Gears: Helical
Gear Ratio: 6.35:1
Rod Bearings: Shell type replaceable
Main Bearings: Straight roller
Pinion Bearings: Spherical roller
Crankshaft: Alloy steel nitrided
Connecting Rod: One piece forged steel
Crosshead: Cast steel
Crosshead Guide: Bronze replaceable
Fluid-End: Plunger type mono-block design
Discharge Connection: 2 or 3 inch half union
forged steel female connection both ends
Suction: 6 or 8 inch pipe w/ grooved connection
Valves and Seats: Service Master II

W-2250 Triplex Plunger Pump


Performance Data
Displacement
Plunger
Factors*
Diameter
@ 100% V. E.
U.S. Gal.
per Rev.
Inches
GPR
7.50
4.590
7.00
3.998
6.75
3.718
6.50
3.448
6.00
2.938
5.75
2.698
5.50
2.468
5.00
2.040
4.50
1.652
4.00
1.306
Input
Brake**
Power
Horsepower
Pinion RPM
@ 6.35:1 Gear Ratio

100
Flow
@ 100% V. E.
U.S. Gal.
per Min.
GPM
459
400
372
345
294
270
247
204
165
131

Max
Press.
@ Flow
PSIG
5659
6496
6986
7534
8842
9628
10523
12732
15719
19894

Pump Speed in Crankshaft Revolutions Per Minute (RPM)


150
200
250
Flow
Max
Flow
Max
Flow
@ 100% V. E.
Press.
@ 100% V. E.
Press.
@ 100% V. E.
U.S. Gal.
@ Flow
U.S. Gal.
@ Flow
U.S. Gal.
per Min.
per Min.
per Min.
GPM
PSIG
GPM
PSIG
GPM
688
4761
918
3571
1147
600
5466
800
4099
1000
558
5878
744
4408
929
517
6339
690
4754
862
441
7439
588
5908
734
405
8100
540
6075
674
370
8853
494
6640
617
306
10713
408
8034
510
248
13225
330
9919
413
196
16738
261
12554
326

330
Max
Press.
@ Flow
PSIG
2857
3279
3527
3803
4464
4860
5312
6428
7935
10043

Flow
@ 100% V. E.
U.S. Gal.
per Min.
GPM
1515
1319
1227
1138
969
890
815
673
545
431

1783

2250

2250

2250

2250

635

953

1270

1588

2096

Max
Press.
@ Flow
PSIG
2164
2484
2672
2881
3381
3682
4024
4869
6012
7608

* V.E. = VOLUMETRIC EFFICIENCY, **BHP (Brake Horsepower) is based on 85% Mechanical Efficiency
The information and data on this sheet is accurate to the best of our knowledge and belief, but are intended for general information only. Applications suggested for the materials are described only to help readers make their own
evaluations and decisions, and are neither guarantees nor to be construed as express or implied warranties of suitability for these or other applications. National Oilwell makes no warranty either express or implied beyond that
stipulated in National Oilwell Standard Terms and Conditions of Sale.

Authorized Distributor:

www.natoil.com / customer.service@natoil.com
10000 Richmond, Houston, Texas 77042
(713)346-7500 (phone) (713)346-7366 (fax)

You might also like