You are on page 1of 48

s

Preformed Metal Floor Deck

ASCSteel Deck

It is our objective to provide the highest quality products


and services in the steel deck industry. This objective is
partially accomplished through conducting extensive testing
programs with independent testing facilities to ensure that
our products comply with the stringent criteria of todays
building codes. Our steel deck products have been evaluated
by the International Conference of Building Officials (ICC
Evaluation Services Report No. 1414), listed by Underwriters
Laboratories, Certified by the Steel Deck Institute and
approved by Factory Mutual and City of Los Angeles.
Additionally, our manufacturing plants are strategically
located in the western United States so that we may provide
the best possible service. Most importantly, our Sales
Representatives, Customer Service and Engineering Services
Departments are prepared to assist you with the specific
requirements of your project.
How To Use This Catalog
This Catalog contains information about Floor Deck, Concrete
Form, and Deep Deck profiles. Included with the profiles are
reaction tables, section properties, design load tables, and
diagrams of the profiles. The Technical/Specification section
contains further information applicable to all profiles.

Table of Contents
Floor Deck
B-36 Composite........................................................................2
N-32 Composite ......................................................................8
2W-36 Composite .................................................................14
3W-36 Composite .................................................................20
3WF-36 Composite ...............................................................30
Concrete Deck Form
CF 7/8 ..................................................................................35
CF 1 3/8 ...............................................................................36
Deep Deck
4 1/2 Deep Deck .................................................................37
6 Deep Deck .......................................................................37
7 1/2 Deep Deck .................................................................38

Step 1: Select the type of application (Floor Deck, Form or


Deep Deck).
Step 2: Identify which profile is appropriate for your specific
design and select the corresponding page number.
Step 3: Contact ASCSteel Deck 1-800-726-2727.

Technical/Specifications
General Notes .......................................................................39
Fire Resistance Ratings ..........................................................40
Concrete Weights and Volumes ...........................................42
General Comments on Extraordinary Conditions .................43
SDI Edge Form ......................................................................44
Floor Deck Accessories and Standard Details ......................45
Materials and Finishes............................................................46
Metric Conversion Chart .......................................................46

December 2013

www.ascsd.com

ASCSteel Deck

B-36 Composite Floor Deck


2-3/8

3-5/8

1-1/2
1-3/4
36
4 Welds

7 Welds
FD_1 B-36

B-36 Section Properties


Weight

Allowable Reactions (plf)


I

S+

S--

Gage

(psf)

(In4)

(In3)

(In3)

22
20
18
16

1.68
2.04
2.70
3.36

0.178
0.220
0.302
0.379

0.180
0.235
0.321
0.407

0.195
0.246
0.336
0.415

Bearing Length
Gage

22
20
18

1. Section Properties are based on minimum 38 ksi steel (Fy)

16

1 1/2

2 1/2

3 1/2

416
1007
700
1495
1443
2734
2434
4350

468
1103
776
1617
1568
2909
2608
4578

520
1213
853
1739
1693
3084
2782
4806

572
1363
929
1897
1818
3258
2957
5034

625
1513
1005
2088
1943
3436
3131
5262

677
1663
1082
2280
2068
3710
3305
5490

729
1813
1158
2472
2193
3985
3480
5786

1. The top value reflects the allowable reaction at the panel end supports.
(prior to concrete cure)
2. The bottom value reflects the allowable reaction at the interior supports.
(prior to concrete cure)
3. Values are in pounds per linear foot.

B-36 Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Lightweight Concrete (110 pcf)
Total Slab Thickness: 3 1/2 Slab Weight: 23.0 psf
Gage

22

20

18

16

Span

No. of
Spans

60

66

70

76

80

86

90

96

100

106

110

116

120

1
2
3
q4
q7
1
2
3
q4
q7
1
2
3
q4
q7
1
2
3
q4
q7

230
230
230
1501
1710
301
301
301
1568
1820
301
301
301
1721
2056
300
300
300
1890
2309

184
204
204
1462
1656
267
267
267
1522
1754
267
267
267
1660
1969
266
266
266
1813
2201

163
183
183
1429
1609
239
239
239
1483
1698
239
239
239
1607
1895
238
238
238
1748
2107

145
165
145
1401
1569
196
216
216
1448
1650
215
215
215
1562
1830
215
215
215
1691
2026

130
130
130
1376
1533
176
196
196
1419
1607
196
196
196
1522
1774
195
195
195
1641
1955

117
117
117
1354
1502
159
179
179
1392
1570
179
179
179
1487
1724
178
178
178
1597
1893

105
105
105
1334
1474
138
138
138
1369
1537
143
164
164
1456
1679
163
163
163
1558
1838

96
96
96
1317
1449
117
117
117
1348
1507
131
151
151
1428
1639
151
151
151
1523
1788

87
87
87
1301
1427
100
100
100
1329
1480
114
140
140
1403
1604
140
140
140
1492
1743

80
80
80
1287
1407
87
87
87
1312
1456
99
99
130
1380
1571
109
130
130
1463
1703

70
70
70
1274
1388
75
75
75
1296
1434
86
86
86
1359
1542
95
121
121
1437
1666

61
61
61
1262
1372
66
66
66
1282
1413
75
75
75
1340
1515
83
83
113
1414
1632

54
54
54
1251
1356
58
58
58
1269
1395
66
66
66
1323
1491
73
73
106
1392
1602

1. In shaded areas, mid-span deck shoring required during construction.


2. q4 and q7 q=allowable diaphragm shear (plf): 4, 7=number of welds to support.
3. See pg. 55 for General Notes.

Preformed Metal Floor Deck

ASCSteel Deck

B-36 Composite Floor Deck


B-36 Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Lightweight Concrete (110 pcf)
Total Slab Thickness: 4
Gage

22

20

18

16

1 Hour Fire Rating

Slab Weight: 27.5 psf


Span

No. of
Spans

60

66

70

76

80

86

90

96

100

106

110

116

120

1
2
3
q4
q7
1
2
3
q4
q7
1
2
3
q4
q7
1
2
3
q4
q7

245
268
268
1659
1868
350
350
350
1726
1978
349
349
349
1879
2214
347
347
347
2048
2467

214
238
238
1620
1814
311
311
311
1680
1912
309
309
309
1818
2127
307
307
307
1971
2359

189
213
213
1587
1767
254
278
278
1641
1856
277
277
277
1765
2053
275
275
275
1906
2265

168
168
168
1559
1727
227
251
251
1606
1808
250
250
250
1720
1988
248
248
248
1849
2184

151
151
151
1534
1691
204
228
228
1577
1765
227
227
227
1680
1931
225
225
225
1799
2113

136
136
136
1512
1660
184
208
208
1550
1728
183
207
207
1645
1882
206
206
206
1755
2051

122
122
122
1492
1632
167
167
167
1527
1695
166
190
190
1614
1837
189
189
189
1716
1995

111
111
111
1475
1607
152
152
152
1506
1665
151
175
175
1586
1797
174
174
174
1681
1946

101
101
101
1459
1585
139
139
139
1487
1638
138
138
162
1561
1762
136
161
161
1650
1901

92
92
92
1445
1565
128
128
128
1470
1614
126
126
126
1538
1729
125
150
150
1621
1861

84
84
84
1432
1546
1147
117
117
1454
1591
116
116
116
1517
1700
115
115
140
1595
1824

77
77
77
1420
1530
108
108
108
1440
1571
107
107
107
1498
1673
106
106
131
1572
1790

71
71
71
1409
1514
100
100
100
1427
1553
99
99
99
1481
1649
98
98
98
1550
1760

B-36 Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Lightweight Concrete (110 pcf)
Total Slab Thickness: 4 3/4
Gage

22

20

18

16

2 Hour Fire Rating

Slab Weight: 34.4 psf

Span

No. of
Spans

60

66

70

76

80

86

90

96

100

106

110

116

120

1
2
3
q4
q7
1
2
3
q4
q7
1
2
3
q4
q7
1
2
3
q4
q7

299
328
328
1895
2105
428
428
428
1963
2215
425
425
425
2116
2451
421
421
421
2285
2704

262
291
291
1857
2051
380
380
380
1917
2149
377
377
377
2055
2364
374
374
374
2208
2595

231
231
231
1824
2004
311
340
340
1878
2093
337
337
337
2002
2290
334
334
334
2143
2502

206
206
206
1796
1964
277
306
306
1843
2045
304
304
304
1957
2225
301
301
301
2086
2421

184
184
184
1771
1928
249
278
278
1813
2002
246
276
276
1917
2168
274
274
274
2036
2350

165
165
165
1749
1897
225
225
225
1787
1965
222
252
252
1882
2119
250
250
250
1992
2288

149
149
149
1729
1869
204
204
204
1764
1931
202
231
231
1851
2074
229
229
229
1953
2232

136
136
136
1712
1844
186
186
186
1743
1902
184
184
213
1823
2034
181
211
211
1918
2183

123
123
123
1696
1822
170
170
170
1724
1875
168
168
168
1798
1999
166
196
196
1886
2138

113
113
113
1682
1802
156
156
156
1707
1851
154
154
154
1775
1966
152
152
182
1858
2098

103
103
103
1669
1783
143
143
143
1691
1828
141
141
141
1754
1937
139
139
170
1832
2061

64
94
94
1657
1767
132
132
132
1677
1808
130
130
130
1735
1910
128
128
128
1808
2027

87
87
87
1646
1751
122
122
122
1664
1790
120
120
120
1718
1886
119
119
119
1787
1996

1. In shaded areas, mid-span deck shoring required during construction.


2. q4 and q7 q=allowable diaphragm shear (plf): 4, 7=number of welds to support.
3. See pg. 55 for General Notes.

December 2013

www.ascsd.com

ASCSteel Deck

B-36 Composite Floor Deck


B-36 Allowable Superimposed Load (psf) Diaphragm Shear Capacity (plf) Lightweight Concrete (110 pcf)
Total Slab Thickness: 5 11/16
Gage

22

20

18

16

3 Hour Fire Rating

Slab Weight: 42.1 psf


Span

No. of
Spans

60

66

70

76

80

86

90

96

100

106

110

116

120

1
2
3
q4
q7
1
2
3
q4
q7
1
2
3
q4
q7
1
2
3
q4
q7

370
405
405
2192
2401
529
529
329
2259
2511
525
525
525
2412
2748
519
519
519
2581
3001

324
359
324
2153
2347
433
469
469
2213
2446
465
465
465
2351
2661
461
461
461
2505
2892

286
286
286
2121
2300
384
420
420
2174
2390
416
416
416
2299
2586
412
412
412
2439
2798

254
254
254
2092
2260
343
343
378
2140
2341
339
375
375
2253
2521
372
372
372
2382
2717

227
227
227
2067
2224
308
308
308
2110
2298
304
341
341
2213
2465
337
337
337
2332
2647

205
205
205
2045
2193
278
278
278
2083
2261
275
311
311
2178
2415
308
308
308
2288
2584

185
185
185
2026
2165
252
252
252
2060
2228
249
249
286
2147
2370
246
283
283
2249
2529

168
168
168
2008
2141
230
230
230
2039
2198
227
227
227
2119
2331
224
261
261
2214
2479

152
152
152
1992
2118
210
210
210
2020
2171
207
207
207
2094
2295
204
204
241
2183
2434

139
139
139
1978
2098
192
192
192
2003
2147
190
190
190
2071
2263
187
187
224
2154
2394

127
127
127
1965
2080
177
177
177
1987
2125
175
175
175
2050
2233
172
172
172
2128
2357

117
117
117
1953
2063
163
163
163
1973
2104
161
161
161
2031
2206
159
159
159
2105
2323

107
107
107
1943
2047
151
151
151
1960
2086
149
149
149
2014
2182
146
146
146
2083
2293

B-36 Allowable Superimposed Load (psf) Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)
Total Slab Thickness: 3 1/2 Slab Weight: 30.3 psf
Gage

22

20

18

16

Span

No. of
Spans

60

66

70

76

80

86

90

96

100

106

110

116

120

1
2
3
q4
q7
1
2
3
q4
q7
1
2
3
q4
q7
1
2
3
q4
q7

205
230
230
1825
2035
301
301
301
1893
2144
301
301
301
2046
2381
300
300
300
2215
2634

179
204
204
1787
1980
267
267
267
1847
2079
267
267
267
1984
2294
266
266
266
2138
2525

157
183
157
1754
1934
213
239
239
1807
2023
239
239
239
1932
2219
238
238
238
2072
2432

139
139
139
1725
1893
190
216
216
1773
1974
215
215
215
1886
2155
215
215
215
2015
2351

124
124
124
1700
1858
170
196
196
1743
1932
196
196
196
1847
2098
195
195
195
1965
2280

111
111
111
1678
1826
153
153
153
1717
1894
152
179
179
1811
2048
178
178
178
1921
2217

100
100
100
1659
1799
138
138
138
1693
1861
137
164
164
1780
2004
163
163
163
1882
2162

90
90
90
1641
1774
125
125
125
1672
1831
125
151
151
1752
1964
124
151
151
1847
2112

81
81
81
1626
1751
114
114
114
1653
1804
113
113
140
1727
1928
113
140
140
1816
2068

74
74
74
1611
1731
104
104
104
1636
1780
104
104
104
1704
1896
103
130
130
1787
2027

67
67
67
1599
1713
95
95
95
1621
1758
95
95
95
1684
1866
94
94
121
1762
1990

61
61
61
1587
1696
83
83
83
1606
1738
87
87
87
1665
1840
86
86
113
1738
1957

55
55
55
1576
1681
73
73
73
1593
1719
80
80
80
1647
1815
79
79
79
1716
1926

1. In shaded areas, mid-span deck shoring required during construction.


2. q4 and q7 q=allowable diaphragm shear (plf): 4, 7=number of welds to support.
3. See pg. 55 for General Notes.

Preformed Metal Floor Deck

ASCSteel Deck

B-36 Composite Floor Deck


B-36 Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)
Total Slab Thickness: 4 Slab Weight: 36.3 psf
Gage

22

20

18

16

Span

No. of
Spans

60

66

70

76

80

86

90

96

100

106

110

116

120

1
2
3
q4
q7
1
2
3
q4
q7
1
2
3
q4
q7
1
2
3
q4
q7

238
268
268
2064
2274
350
350
350
2132
2383
349
349
349
2285
2620
347
347
347
2454
2873

207
238
238
2026
2219
280
311
311
2086
2318
309
309
309
2223
2533
307
307
307
2377
2764

182
182
182
1993
2173
247
278
278
2046
2262
277
277
277
2171
2458
275
275
275
2311
2671

161
161
161
1964
2132
220
251
251
2012
2213
250
250
250
2125
2394
248
248
248
2254
2590

144
144
144
1940
2097
197
197
197
1982
2171
195
227
227
2086
2337
225
225
225
2205
2519

128
128
128
1918
2066
177
177
177
1956
2133
176
207
207
2050
2287
206
206
206
2161
2457

115
115
115
1898
2038
160
160
160
1932
2100
159
190
190
2019
2243
157
189
189
2121
2401

104
104
104
1881
2013
145
145
145
1911
2070
144
144
175
1991
2203
142
174
174
2087
2351

94
94
94
1865
1991
132
132
132
1892
2043
131
131
131
1966
2167
129
161
161
2055
2307

85
85
85
1851
1970
121
121
121
1875
2019
119
119
119
1943
2135
118
118
150
2027
2266

77
77
77
1838
1952
110
110
110
1860
1997
109
109
109
1923
2106
108
108
108
2001
2229

70
70
70
1826
1935
101
101
101
1846
1977
100
100
100
1904
2079
99
99
99
1977
2196

64
64
64
1815
1920
93
93
93
1833
1958
92
92
92
1887
2054
91
91
91
1955
2165

B-36 Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)
Total Slab Thickness: 5
Gage

22

20

18

16

1 Hour Fire Rating

Slab Weight: 48.4 psf


Span

No. of
Spans

60

66

70

76

80

86

90

96

100

106

110

116

120

1
2
3
q4
q7
1
2
3
q4
q7
1
2
3
q4
q7
1
2
3
q4
q7

308
348
348
2542
2752
414
455
455
2610
2862
451
451
451
2763
3098
447
447
447
2932
3351

269
269
269
2504
2697
363
403
403
2564
2796
400
400
400
2702
3011
396
396
396
2855
3242

236
236
236
2471
2651
321
361
361
2524
2740
358
358
358
2649
2936
355
355
355
2789
3149

209
209
209
2443
2610
285
285
285
2490
2692
282
323
323
2604
2872
320
320
320
2733
3068

186
186
186
2418
2575
255
255
255
2460
2649
252
293
293
2564
2815
290
290
290
2683
2997

166
166
166
2396
2544
229
229
229
2434
2612
227
227
268
2529
2765
224
265
265
2639
2935

149
149
149
2376
2516
207
207
207
2410
2578
205
205
205
2497
2721
202
243
243
2600
2879

135
135
135
2359
2491
188
188
188
2389
2548
186
186
186
2469
2681
183
183
224
2565
2830

122
122
122
2343
2469
171
171
171
2371
2522
169
169
169
2444
2645
166
166
208
2533
2785

110
110
110
2329
2449
156
156
156
2353
2497
154
154
154
2422
2613
152
152
152
2505
2744

100
100
100
2316
2430
143
143
143
2338
2475
141
141
141
2401
2584
139
139
139
2479
2708

91
91
91
2304
2413
131
131
131
2324
2455
129
129
129
2382
2557
127
127
127
2455
2674

82
82
82
2293
2398
120
120
120
2311
2437
118
118
118
2365
2532
116
116
116
2434
2643

1. In shaded areas, mid-span deck shoring required during construction.


2. q4 and q7 q=allowable diaphragm shear (plf): 4, 7=number of welds to support.
3. See pg. 55 for General Notes.

December 2013

www.ascsd.com

ASCSteel Deck

B-36 Composite Floor Deck


B-36 Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)
Total Slab Thickness: 5 1/2
Gage

22

20

18

16

1 1/2 Hour Fire Rating

Slab Weight: 54.4 psf


Span

No. of
Spans

60

66

70

76

80

86

90

96

100

106

110

116

120

1
2
3
q4
q7
1
2
3
q4
q7
1
2
3
q4
q7
1
2
3
q4
q7

345
389
345
2781
2991
464
509
509
2849
3101
504
504
504
3002
3337
500
500
500
3171
3590

301
301
301
2743
2937
406
451
451
2803
3035
447
447
447
2941
3250
443
443
443
3094
3481

264
264
264
2710
2890
359
359
404
2763
2979
355
400
400
2888
3176
396
396
396
3029
3388

234
234
234
2682
2849
319
319
319
2729
2931
315
361
361
2843
3111
357
357
357
2972
3307

208
208
208
2657
2814
285
285
285
2699
2888
282
328
328
2803
3054
278
324
324
2922
3236

186
186
186
2635
2783
257
257
257
2673
2851
254
254
254
2768
3004
250
296
296
2878
3174

167
167
167
2615
2755
232
232
232
2649
2817
229
229
229
2737
2760
226
226
272
2839
3118

151
151
151
2598
2730
210
210
210
2628
2787
208
208
208
2709
2920
205
205
251
2804
3069

136
136
136
2582
2708
191
191
191
2610
2761
189
189
189
2683
2885
186
186
186
2772
3024

123
123
123
2568
2688
174
174
174
2593
2736
172
172
172
2661
2852
169
169
169
2744
2983

112
112
112
2555
2669
159
159
159
2577
2714
157
157
157
2640
2823
155
155
155
2718
2947

101
101
101
2543
2652
146
146
146
2563
2694
144
144
144
2621
2796
142
142
142
2694
2913

92
92
92
2532
2637
134
134
134
2550
2676
132
132
132
2604
2771
130
130
130
2673
2882

B-36 Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)
Total Slab Thickness: 6
Gage

22

20

18

16

2 Hour Fire Rating

Slab Weight: 60.4 psf

Span

No. of
Spans

60

66

70

76

80

86

90

96

100

106

110

116

120

1
2
3
q4
q7
1
2
3
q4
q7
1
2
3
q4
q7
1
2
3
q4
q7

382
382
382
3020
3230
513
563
563
3088
3340
559
559
559
3241
3576
553
553
553
3410
3829

333
333
333
2982
3176
450
499
499
3042
3274
495
495
495
3180
3489
490
490
490
3333
3720

293
293
293
2949
3129
397
397
397
3002
3218
393
443
443
3127
3415
439
439
439
3268
3627

259
259
259
2921
3088
353
353
353
2968
3170
349
400
400
3082
3350
396
396
396
3211
3546

231
231
231
2896
3053
316
316
316
2928
3127
312
312
363
3042
3293
308
359
359
3161
3475

206
206
206
2874
3022
284
284
284
2912
3090
281
281
281
3007
3243
277
328
328
3117
3413

185
185
185
2854
2994
257
257
257
2889
3056
254
254
254
2976
3199
250
250
301
3078
3357

167
167
167
2837
2969
233
233
233
2868
3027
230
230
230
2948
3159
227
227
227
3043
3308

151
151
151
2821
2947
212
212
212
2849
3000
209
209
209
2923
3124
206
206
206
3011
3263

136
136
136
2807
2927
193
193
193
2832
2975
191
191
191
2900
3091
188
188
188
2983
3223

124
124
124
2794
2908
177
177
177
2816
2953
174
174
174
2879
3062
172
172
172
2957
3186

112
112
112
2782
2892
162
162
162
2802
2933
160
160
160
2860
3035
157
157
157
2933
3152

100
100
100
2771
2876
149
149
149
2789
2915
147
147
147
2843
3010
144
144
144
2912
3121

1. In shaded areas, mid-span deck shoring required during construction.


2. q4 and q7 q=allowable diaphragm shear (plf): 4, 7=number of welds to support.
3. See pg. 55 for General Notes.

Preformed Metal Floor Deck

ASCSteel Deck

B-36 Composite Floor Deck


B-36 Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)
Total Slab Thickness: 6 3/4
Gage

22

20

18

16

3 Hour Fire Rating

Slab Weight: 69.5 psf


Span

No. of
Spans

60

66

70

76

80

86

90

96

100

106

110

116

120

1
2
3
q4
q7
1
2
3
q4
q7
1
2
3
q4
q7
1
2
3
q4
q7

438
438
438
3379
3589
589
646
646
3447
3698
641
641
641
3600
3935
634
634
634
3769
4188

382
382
382
3341
3534
516
516
516
3401
3633
511
568
568
3538
3848
563
563
563
3692
4079

336
336
336
3308
3488
456
456
456
3361
3577
451
509
509
3486
3773
503
503
503
3626
3986

297
297
297
3279
3447
405
405
405
3327
3528
401
401
459
3440
3709
396
454
454
3569
3905

265
265
265
3254
3412
363
363
363
3297
3486
359
359
359
3401
3652
354
412
412
3519
3834

237
237
237
3232
3380
326
326
326
3271
3448
322
322
322
3365
3602
318
318
376
3476
3772

213
213
213
3213
3353
295
295
295
3247
3415
291
291
291
3334
3588
287
287
287
3436
3716

191
191
191
3195
3328
267
267
267
3226
3385
264
264
264
3306
3518
260
260
260
3401
3666

173
173
173
3180
3306
243
243
243
3207
3358
240
240
240
3281
3482
237
237
237
3370
3622

157
157
157
3166
3285
222
222
222
3190
3334
219
219
219
3238
3450
216
216
216
3342
3581

142
142
142
3153
3267
203
203
203
3175
3312
200
200
200
3258
3421
197
197
197
3316
3544

127
127
127
3141
3280
186
186
186
3160
3292
184
184
184
3219
3394
181
181
181
3292
3511

112
112
112
3130
3235
171
171
171
3147
3273
168
168
168
3201
3369
166
166
166
3270
3480

1. In shaded areas, mid-span deck shoring required during construction.


2. q4 and q7 q=allowable diaphragm shear (plf): 4, 7=number of welds to support.
3. See pg. 55 for General Notes.

December 2013

www.ascsd.com

ASCSteel Deck

N-32 Composite Floor Deck


8

4-1/8

3-7/8

N-32 Allowable Reactions (plf)


Bearing Length
Gage
2-1/8

5-7/8

22
32

3 Welds5

20

Welds

N-32 Section Properties

18

Weight

S+

S--

Gage

(psf)

(In4)

(In3)

(In3)

22
20
18
16

1.87
2.24
2.95
3.68

1.870
2.300
3.187
4.100

0.3631
0.4659
0.6926
0.8910

0.4147
0.5207
0.7339
0.9308

16

1 1/2

2 1/2

3 1/2

400
701
567
992
977
1706
1491
2608

453
779
640
1097
1094
1874
1660
2848

498
845
701
1186
1192
2015
1803
3051

537
903
754
1264
1279
2140
1929
3230

573
955
803
1335
1358
2253
2043
3391

605
1003
848
1400
1430
2356
2147
3539

636
1048
890
1461
1497
2453
2245
3677

1. The top value reflects the allowable reaction at the panel end supports.
(prior to concrete cure)
2. The bottom value reflects the allowable reaction at the interior supports.
(prior to concrete cure)
3. Values are in pounds per linear foot.

1. Section properties are based on minimum 38 ksi steel (Fy)

N32 Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Lightweight Concrete (110 pcf)
Total Slab Thickness: 5
Gage

22

20

18

16

No. of
Spans

8'-0"

8'-6"

9'-0"

9'-6"

Vertical Load Span (ft-in)


10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

1, 2 or 3
q5
q3
1, 2 or 3
q5
q3
1, 2 or 3
q5
q3
1, 2 or 3
q5
q3

208
1014
1001
247
1064
1049
318
1171
1150
387
1287
1262

182
1000
988
216
1047
1033
279
1148
1128
340
1257
1233

160
988
977
190
1033
1019
246
1127
1109
301
1230
1207

141
985
974
168
1030
1017
219
1126
1109
267
1234
1212

125
975
965
150
1017
1005
195
1109
1093
239
1211
1190

Maximum
Unshored
Span

88

Slab Weight: 29.7 psf

111
966
956
133
1006
995
174
1093
1078
214
1190
1171

99
957
948
119
996
985
157
1079
1064
193
1171
1153

89
950
941
107
987
976
141
1066
1052
175
1154
1136

79
943
935
97
978
968
128
1054
1040
158
1138
1121

71
942
934
87
978
968
116
1056
1043
144
1145
1128

64
936
928
79
971
961
105
1046
1033
131
1131
1115

Number of spans

58
931
923
71
964
955
96
1036
1024
120
1117
1102

52
925
918
65
957
949
87
1027
1015
110
1105
1090

47
42
921 916
914 909
59
53
951 946
943 938
80
73
1018 1010
1007 999
101
92
1094 1083
1079 1069

Number of spans

Gage

Gage

22
20

9' - 5"
11' - 0"

10' - 4"
12' - 3"

11' - 2"
12' - 10"

18
16

13' - 7"
14' - 5"

14' - 8"
16' - 5"

15' - 2"
16' - 11"

Preformed Metal Floor Deck

ASCSteel Deck

N-32 Composite Floor Deck


N32 Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Lightweight Concrete (110 pcf)
Total Slab Thickness: 5 1/2
Gage

22

20

18

16

1 Hour Fire Rating

Slab Weight: 34.3 psf

No. of
Spans

8'-0"

8'-6"

9'-0"

9'-6"

Vertical Load Span (ft-in)


10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

1, 2 or 3
q5
q3
1, 2 or 3
q5
q3
1, 2 or 3
q5
q3
1, 2 or 3
q5
q3

247
1213
1200
293
1263
1248
378
1370
1350
460
1487
1461

216
1200
1188
257
1247
1232
332
1347
1328
404
1457
1432

189
1188
1176
226
1232
1219
293
1326
1308
358
1430
1407

167
1184
1173
200
1229
1216
260
1326
1309
318
1434
1412

148
1174
1164
178
1217
1205
232
1309
1292
284
1411
1390

Maximum
Unshored
Span

132
1165
1155
159
1206
1194
208
1293
1277
255
1390
1370

118
1157
1148
142
1195
1184
187
1278
1264
230
1371
1352

106
1149
1141
128
1186
1176
168
1265
1251
208
1354
1336

95
1143
1134
115
1178
1168
152
1253
1240
189
1338
1320

85
1142
1133
104
1178
1168
138
1256
1243
172
1344
1328

77
1136
1128
94
1170
1161
126
1245
1233
157
1330
1314

Number of spans

69
1130
1122
85
1163
1154
115
1235
1223
143
1317
1301

62
1125
1118
77
1157
1148
105
1226
1214
131
1304
1290

56
1120
1113
70
1151
1142
96
1218
1206
120
1293
1279

51
1116
1109
64
1145
1137
87
1210
1199
110
1282
1269

Number of spans

Gage

Gage

22
20

9' - 0"
10' - 6"

9' - 11"
11' - 9"

10' - 8"
12' - 4"

18
16

13' - 2"
13' - 11"

14' - 1"
15' - 9"

14' - 6"
16' - 3"

N32 Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Lightweight Concrete (110 pcf)
Total Slab Thickness: 6 1/4
Gage

22

20

18

16

2 Hour Fire Rating

Slab Weight: 41.3 psf

No. of
Spans

8'-0"

8'-6"

9'-0"

9'-6"

Vertical Load Span (ft-in)


10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

1, 2 or 3
q5
q3
1, 2 or 3
q5
q3
1, 2 or 3
q5
q3
1, 2 or 3
q5
q3

310
1512
1500
369
1562
1547
477
1669
1649
581
1786
1760

271
1499
1487
323
1546
1532
418
1646
1627
511
1756
1731

238
1487
1476
285
1531
1518
370
1626
1607
452
1729
1706

211
1483
1472
252
1528
1515
328
1625
1608
402
1733
1711

187
1473
1463
224
1516
1504
293
1608
1591
360
1710
1689

Maximum
Unshored
Span

December 2013

167
1464
1455
201
1505
1493
263
1592
1576
323
1689
1669

149
1456
1447
180
1495
1483
236
1578
1563
291
1670
1651

133
1449
1440
162
1485
1475
213
1565
1550
264
1653
1635

120
1442
1433
146
1477
1467
193
1553
1539
240
1637
1620

108
1441
1433
132
1477
1467
176
1555
1542
218
1643
1627

97
1435
1427
119
1469
1460
160
1544
1532
199
1629
1613

Number of spans

88
1429
1422
108
1462
1453
146
1534
1522
182
1616
1601

80
1424
1417
99
1456
1447
133
1525
1514
167
1604
1589

72
1419
1412
90
1450
1441
122
1517
1505
153
1592
1578

65
1415
1408
82
1444
1436
112
1509
1498
141
1582
1568

Number of spans

Gage

Gage

22
20

8' - 6"
9' - 11"

9' - 5"
11' - 1"

10' - 0"
11' - 8"

18
16

12' - 7"
13' - 5"

13' - 4"
14' - 11"

13' - 9"
15' - 5"

www.ascsd.com

ASCSteel Deck

N-32 Composite Floor Deck


N32 Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Lightweight Concrete (110 pcf)
Total Slab Thickness: 7 3/16
Gage

22

20

18

16

3 Hour Fire Rating

Slab Weight: 50.1 psf

No. of
Spans

8'-0"

8'-6"

9'-0"

9'-6"

Vertical Load Span (ft-in)


10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

1, 2 or 3
q5
q3
1, 2 or 3
q5
q3
1, 2 or 3
q5
q3
1, 2 or 3
q5
q3

396
1886
1873
471
1936
1921
611
2043
2023
747
2160
2134

346
1873
1861
413
1920
1906
537
2020
2001
657
2130
2105

305
1861
1849
364
1905
1892
474
2000
1981
582
2103
2080

269
1857
1846
323
1902
1889
422
1999
1982
518
2107
2085

239
1847
1837
288
1890
1878
377
1982
1965
463
2084
2063

Maximum
Unshored
Span

213
1838
1828
257
1879
1867
338
1966
1950
417
2063
2043

191
1830
1821
231
1869
1857
304
1951
1937
376
2044
2025

171
1822
1814
208
1859
1849
275
1938
1924
341
2027
2009

154
1816
1807
188
1851
1841
249
1926
1913
310
2011
1993

139
1815
1806
170
1851
1841
227
1929
1916
282
2017
2001

126
1809
1801
154
1843
1834
207
1918
1906
258
2003
1987

Number of spans

114
1803
1796
140
1836
1827
189
1908
1896
236
1990
1974

103
1798
1791
128
1830
1821
173
1899
1887
217
1978
1963

93
1793
1786
116
1824
1815
158
1891
1879
199
1966
1952

85
1789
1782
106
1818
1810
145
1883
1872
184
1955
1942

Number of spans

Gage

Gage

22
20

7' - 11"
9' - 3"

8' - 11"
10' - 5"

9' - 4"
10' - 10"

18
16

11' - 9"
12' - 10"

12' - 6"
14' - 0"

12' - 11"
14' - 6"

N32 Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)
Total Slab Thickness: 5
Gage

22

20

18

16

No. of
Spans

8'-0"

8'-6"

9'-0"

9'-6"

Vertical Load Span (ft-in)


10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

1, 2 or 3
q5
q3
1, 2 or 3
q5
q3
1, 2 or 3
q5
q3
1, 2 or 3
q5
q3

213
1417
1404
255
1466
1451
332
1570
1550
407
1685
1659

185
1404
1392
222
1450
1435
290
1547
1528
357
1655
1630

162
1392
1380
195
1435
1421
256
1527
1509
315
1628
1605

142
1388
1377
172
1432
1419
226
1526
1509
280
1631
1610

125
1378
1368
152
1420
1407
201
1509
1492
249
1608
1588

Maximum
Unshored
Span

10

Slab Weight: 39.1 psf

111
1369
1359
135
1408
1397
179
1493
1477
223
1588
1568

98
1361
1352
120
1398
1387
161
1479
1464
200
1569
1550

87
1353
1345
107
1389
1378
144
1466
1451
181
1551
1533

78
1347
1338
96
1381
1370
130
1454
1440
163
1536
1518

69
1346
1337
86
1380
1371
117
1456
1443
148
1542
1526

62
1340
1332
77
1373
1363
106
1446
1433
134
1528
1512

Number of spans

55
1334
1326
69
1366
1357
96
1436
1424
122
1515
1499

49
1329
1322
62
1359
1351
87
1426
1415
111
1502
1488

43
1324
1317
56
1353
1345
79
1418
1407
102
1491
1477

39
1320
1313
50
1348
1340
72
1410
1399
93
1480
1466

Number of spans

Gage

Gage

22
20

8' - 7"
10' - 0"

9' - 6"
11' - 3"

10' - 1"
11' - 9"

18
16

12' - 8"
13' - 6"

13' - 5"
15' - 0"

13' - 11"
15' - 6"

Preformed Metal Floor Deck

ASCSteel Deck

N-32 Composite Floor Deck


N32 Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)
Total Slab Thickness: 6 1/2
Gage

22

20

18

16

1 Hour Fire Rating

Slab Weight: 57.6 psf

No. of
Spans

8'-0"

8'-6"

9'-0"

9'-6"

Vertical Load Span (ft-in)


10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

1, 2 or 3
q5
q3
1, 2 or 3
q5
q3
1, 2 or 3
q5
q3
1, 2 or 3
q5
q3

339
2322
2310
407
2372
2356
532
2476
2455
655
2590
2564

295
2309
2297
355
2355
2341
466
2453
2433
575
2560
2536

258
2297
2286
312
2340
2327
411
2432
2414
508
2533
2510

227
2293
2283
275
2337
2324
364
2432
2414
451
2537
2515

201
2284
2273
244
2325
2313
324
2414
2398
403
2514
2493

Maximum
Unshored
Span

178
2275
2265
217
2314
2302
290
2399
2383
361
2493
2473

158
2266
2257
194
2304
2293
260
2384
2369
325
2474
2455

141
2259
2250
174
2294
2284
234
2371
2357
293
2457
2439

126
2252
2244
156
2286
2276
211
2359
2345
266
2441
2424

113
2251
2243
140
2286
2276
191
2362
2349
241
2448
2431

101
2245
2237
126
2278
2269
173
2351
2338
219
2433
2417

Number of spans

90
2239
2232
114
2271
2262
157
2341
2329
200
2420
2405

81
2234
2227
103
2265
2256
143
2332
2320
183
2408
2393

72
2229
2222
93
2259
2250
130
2323
2312
167
2396
2382

65
2225
2218
84
2253
2245
119
2315
2304
153
2386
2372

Number of spans

Gage

Gage

22
20

7' - 6"
8' - 9"

8' - 6"
9' - 11"

8' - 10"
10' - 3"

18
16

11' - 1"
12' - 5"

11' - 10"
13' - 3"

12' - 3"
13' - 9"

N32 Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)
Total Slab Thickness: 7 1/2
Gage

22

20

18

16

2 Hour Fire Rating

Slab Weight: 34.3 psf

No. of
Spans

8'-0"

8'-6"

9'-0"

9'-6"

Vertical Load Span (ft-in)


10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

1, 2 or 3
q5
q3
1, 2 or 3
q5
q3
1, 2 or 3
q5
q3
1, 2 or 3
q5
q3

432
2926
2913
519
2975
2960
681
3079
3059
841
3194
3168

377
2913
2901
454
2959
2944
597
3056
3037
738
3164
3139

330
2901
2889
399
2944
2930
527
3036
3018
653
3137
3114

291
2897
2886
352
2941
2928
467
3035
3018
580
3140
3119

257
2887
2877
313
2929
2916
416
3018
3001
518
3117
3097

Maximum
Unshored
Span

December 2013

228
2878
2868
279
2917
2906
373
3002
2986
465
3097
3077

203
2870
2861
249
2907
2896
335
2988
2973
419
3078
3059

181
2862
2854
223
2898
2887
301
2975
2960
378
3060
3042

162
2856
2847
201
2890
2879
272
2963
2949
343
3045
3027

145
2855
2846
181
2889
2880
247
2965
2952
312
3051
3035

130
2849
2841
163
2882
2872
224
2955
2942
284
3037
3021

Number of spans

117
2843
2836
147
2875
2866
204
2945
2933
259
3024
3008

105
2838
2831
133
2869
2860
186
2935
2924
237
3011
2997

94
2833
2826
120
2863
2854
169
2927
2916
218
3000
2986

84
2829
2822
109
2857
2849
155
2919
2908
200
2989
2975

Number of spans

Gage

Gage

22
20

7' - 0"
8' - 2"

7' - 11"
9' - 3"

8' - 3"
9' - 7"

18
16

10' - 3"
11' - 10"

11' - 1"
12' - 5"

11' - 5"
12' - 10"

www.ascsd.com

11

ASCSteel Deck

N-32 Composite Floor Deck


N32 Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)
Total Slab Thickness: 8 1/4
Gage

22

20

18

16

Slab Weight: 79.1 psf

8'-0"

8'-6"

9'-0"

9'-6"

Vertical Load Span (ft-in)


10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0" 13'-6" 14'-0" 14'-6" 15'-0"

1, 2 or 3
q5
q3
1, 2 or 3
q5
q3
1, 2 or 3
q5
q3
1, 2 or 3
q5
q3

505
3379
3366
607
3428
3413
798
3532
3512
987
3646
3621

440
3365
3353
531
3411
3397
700
3509
3490
867
3616
3592

386
3353
3342
467
3397
3383
618
3489
3470
767
3589
3566

340
3350
3339
413
3394
3381
548
3488
3471
682
3593
3571

301
3340
3330
367
3381
3369
489
3471
3454
609
3570
3549

Maximum
Unshored
Span

12

3 Hour Fire Rating

No. of
Spans

268
3331
3321
327
3370
3358
438
3455
3439
547
3549
3530

238
3323
3313
292
3360
3349
393
3441
3426
493
3530
3512

213
3315
3306
262
3351
3340
355
3427
3413
446
3513
3495

191
3308
3300
236
3342
3332
321
3415
3402
404
3497
3480

171
3307
3299
213
3342
3332
291
3418
3405
368
3504
3487

153
3301
3293
192
3335
3325
264
3407
3395
335
3490
3474

Number of spans

138
3296
3288
174
3328
3319
240
3397
3385
306
3476
3461

124
3291
3283
157
3321
3312
219
3388
3376
280
3464
3449

111
3286
3279
142
3315
3307
200
3380
3368
257
3453
3438

100
3281
3274
129
3310
3301
183
3372
3361
236
3442
3428

Number of spans

Gage

Gage

22
20

6' - 9"
7' - 9"

7' - 7"
8' - 10"

7' - 10"
9' - 1"

18
16

9' - 9"
11' - 3"

10' - 7"
11' - 10"

10' - 11"
12' - 3"

Preformed Metal Floor Deck

December 2013

www.ascsd.com

13

ASCSteel Deck

2W-36 Composite Floor Deck

2W-36 - Allowable Reactions (plf)


Bearing Length

12

Gage

22
2-1/8

21

5
36

20

3 Welds
4 Welds
2W also available in 24 coverage
FD_3 2W-36

19

2W-36 - Section Properties


Weight

S+

S--

Gage

(psf)

(In4)

(In3)

(In3)

22
21
20
19
18
16

1.6
1.8
1.9
2.3
2.5
3.1

0.352
0.407
0.432
0.521
0.580
0.723

0.282
0.335
0.361
0.457
0.527
0.655

0.281
0.335
0.361
0.464
0.526
0.654

1. Section properties are based on minimum 40 ksi steel (Fy)

14

18
16

1 1/2

2 1/2

3 1/2

253
423
322
540
360
604
506
853
625
1055
955
1622

286
470
364
599
406
668
569
940
700
1159
1064
1772

315
510
399
648
445
723
621
1013
763
1247
1156
1898

340
545
430
692
479
771
668
1077
819
1324
1237
2010

362
577
459
731
510
814
710
1136
870
1394
1310
2110

383
606
484
767
539
854
748
1189
916
1459
1377
2203

403
634
509
801
565
891
784
1239
959
1518
1440
2289

1. The top value reflects the allowable reaction at the panel end supports.
(prior to concrete cure)
2. The bottom value reflects the allowable reaction at the interior supports.
(prior to concrete cure)
3. Values are in pounds per linear foot.

Preformed Metal Floor Deck

ASCSteel Deck

2W-36 Composite Floor Deck


2W-36 Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Light Weight Concrete (110 pcf)
Total Slab Thickness: 4
Gage

22
21
20
19
18
16

Slab Weight: 27.5 psf

No. of
Spans

6'-0"

6'-6"

7'-0"

7'-6"

8'-0"

8'-6"

1, 2 or 3
36/4
36/3
1, 2 or 3
36/4
36/3
1, 2 or 3
36/4
36/3
1, 2 or 3
36/4
36/3
1, 2 or 3
36/4
36/3
1, 2 or 3
36/4
36/3

306
1027
1005
336
1069
1045
362
1091
1065
417
1169
1137
466
1226
1191
562
1370
1326

258
1014
994
283
1056
1033
305
1077
1053
352
1155
1126
394
1213
1181
476
1360
1319

219
994
976
241
1033
1012
260
1053
1031
300
1125
1098
336
1178
1148
407
1314
1277

188
977
960
207
1013
994
224
1031
1011
259
1098
1074
290
1148
1120
352
1275
1240

163
962
946
179
996
977
194
1013
994
225
1075
1052
252
1122
1096
306
1241
1208

141
949
934
156
980
963
169
996
978
196
1055
1033
221
1099
1074
269
1210
1179

Maximum
Unshored
Span

Vertical Load Span (ft-in)


9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6"

Number of spans
2

Gage

22
21
20

8' - 1"
9' - 1"
9' - 7"

8' - 8"
9' - 10"
10' - 5"

124
937
923
137
967
950
149
982
965
173
1037
1016
195
1078
1055
237
1183
1154

109
933
919
121
963
948
131
978
962
153
1035
1015
172
1077
1055
210
1186
1158

96
923
910
107
951
937
116
966
951
136
1020
1001
153
1060
1039
188
1163
1137

85
914
902
95
941
927
103
955
940
121
1006
988
137
1044
1024
164
1142
1117

13'-0"

76
67
60
54
906 899 892 891
894 887 881 880
84
75
67
60
932 923 915 915
918 911 903 903
92
82
74
66
945 936 927 927
931 922 915 915
108
97
87
79
993 982 972 972
976 966 956 957
123 111 100
89
1030 1017 1005 1007
1011 998 987 990
143 125 110
97
1123 1106 1090 1096
1099 1083 1068 1075
Number of spans
2

Gage

9' - 8"
10' - 6"
11' - 0"

19
18
16

11' - 1"
11' - 7"
12' - 1"

11' - 11"
12' - 9"
14' - 0"

48
885
875
54
908
896
60
919
908
71
963
949
79
996
980
86
1082
1061
3

12' - 3"
13' - 2"
14' - 2"

2W-36 Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Light Weight Concrete (110 pcf)
Total Slab Thickness: 4 1/2
Gage

22
21
20
19
18
16

1 Hour Fire Rating

Slab Weight: 32.1 psf

No. of
Spans

6'-0"

6'-6"

7'-0"

7'-6"

8'-0"

8'-6"

1, 2 or 3
36/4
36/3
1, 2 or 3
36/4
36/3
1, 2 or 3
36/4
36/3
1, 2 or 3
36/4
36/3
1, 2 or 3
36/4
36/3
1, 2 or 3
36/4
36/3

371
1226
1205
408
1269
1244
439
1290
1264
506
1368
1337
566
1425
1390
684
1569
1525

313
1213
1194
343
1255
1233
370
1277
1253
427
1354
1326
478
1412
1380
578
1559
1518

266
1193
1175
293
1232
1211
316
1252
1230
365
1324
1297
409
1378
1348
495
1514
1476

228
1176
1159
252
1212
1193
272
1231
1210
314
1298
1273
353
1348
1320
428
1474
1439

198
1161
1145
218
1195
1177
236
1212
1193
273
1275
1252
307
1321
1295
373
1440
1407

172
1148
1133
190
1180
1163
206
1196
1178
239
1255
1233
269
1298
1274
327
1410
1378

Maximum
Unshored
Span
December 2013

Number of spans
2

Gage

22
21
20

7' - 9"
8' - 8"
9' - 2"

8' - 5"
9' - 6"
10' - 1"

Vertical Load Span (ft-in)


9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"

151
1136
1122
167
1166
1150
181
1181
1164
210
1237
1216
237
1278
1255
289
1383
1353

133
1132
1119
147
1162
1147
160
1178
1161
186
1234
1215
210
1277
1255
257
1386
1358

117
1122
1110
130
1151
1136
142
1166
1150
165
1219
1200
187
1259
1238
229
1362
1336

104
1113
1101
116
1141
1127
126
1154
1140
147
1205
1188
167
1243
1224
205
1342
1316

93
1105
1094
103
1131
1118
113
1144
1130
132
1193
1176
150
1229
1210
184
1323
1299

74
1091
1081
83
1115
1103
91
1127
1114
107
1171
1155
122
1204
1187
151
1289
1267

Number of spans
2

Gage

9' - 2"
10' - 1"
10' - 6"

19
18
16

10' - 7"
11' - 2"
11' - 9"

www.ascsd.com

82
1098
1087
92
1123
1110
101
1135
1122
119
1181
1165
135
1216
1198
167
1305
1282

11' - 5"
12' - 2"
13' - 5"

66
1090
1080
74
1114
1102
82
1126
1114
96
1172
1157
111
1206
1189
135
1295
1274

59
1084
1074
67
1107
1096
73
1119
1107
87
1162
1148
100
1195
1179
120
1281
1261
3

11' - 9"
12' - 7"
13' - 9"
15

ASCSteel Deck

2W-36 Composite Floor Deck


2W-36 Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Light Weight Concrete (110 pcf)
Total Slab Thickness: 5 1/4
Gage

22
21
20
19
18
16

2 Hour Fire Rating

Slab Weight: 39.2 psf

No. of
Spans

6'-0"

6'-6"

7'-0"

7'-6"

8'-0"

8'-6"

1, 2 or 3
36/4
36/3
1, 2 or 3
36/4
36/3
1, 2 or 3
36/4
36/3
1, 2 or 3
36/4
36/3
1, 2 or 3
36/4
36/3
1, 2 or 3
36/4
36/3

475
1525
1504
522
1568
1543
563
1589
1564
649
1667
1636
728
1724
1690
881
1868
1824

401
1512
1493
440
1554
1532
475
1576
1552
548
1653
1625
615
1711
1679
746
1858
1818

341
1493
1474
375
1531
1511
405
1551
1529
468
1623
1597
526
1677
1647
639
1813
1775

293
1475
1458
323
1512
1492
349
1530
1509
404
1597
1572
454
1647
1619
552
1774
1738

254
1460
1444
280
1494
1476
303
1511
1492
351
1574
1551
396
1621
1594
481
1739
1706

221
1447
1432
244
1479
1462
265
1495
1477
307
1554
1532
347
1598
1573
423
1709
1678

Maximum
Unshored
Span

Vertical Load Span (ft-in)


9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6"

Number of spans
2

Gage

22
21
20

7' - 4"
8' - 2"
8' - 7"

8' - 0"
9' - 0"
9' - 7"

194
1435
1421
215
1465
1449
233
1480
1463
271
1536
1515
306
1577
1554
374
1682
1652

171
1431
1418
189
1461
1446
206
1477
1461
240
1533
1514
272
1576
1554
332
1685
1657

151
1421
1409
168
1450
1435
183
1465
1449
213
1518
1499
242
1558
1537
297
1662
1635

135
1413
1400
149
1440
1426
163
1454
1439
191
1504
1487
217
1543
1523
266
1641
1615

120
1404
1393
133
1430
1417
146
1444
1429
171
1492
1475
195
1528
1509
239
1622
1598

107
1397
1386
119
1422
1409
131
1434
1421
154
1481
1464
175
1515
1497
216
1604
1581

96
1390
1380
107
1414
1402
118
1426
1413
139
1470
1455
159
1503
1486
196
1588
1566

Number of spans
2

Gage

8' - 8"
9' - 6"
9' - 11"

19
18
16

9' - 11"
10' - 6"
11' - 3"

10' - 9"
11' - 6"
12' - 8"

13'-0"

86
1389
1379
96
1413
1401
106
1425
1413
125
1471
1456
144
1505
1488
178
1594
1573

77
1383
1373
87
1406
1395
96
1418
1406
113
1462
1447
131
1495
1478
162
1580
1560
3

11' - 1"
11' - 11"
13' - 1"

2W-36 Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Light Weight Concrete (110 pcf)
Total Slab Thickness: 6 3/16
Gage

22
21
20
19
18
16

Slab Weight: 47.9 psf

No. of
Spans

6'-0"

6'-6"

7'-0"

7'-6"

8'-0"

8'-6"

1, 2 or 3
36/4
36/3
1, 2 or 3
36/4
36/3
1, 2 or 3
36/4
36/3
1, 2 or 3
36/4
36/3
1, 2 or 3
36/4
36/3
1, 2 or 3
36/4
36/3

613
1899
1878
673
1942
1917
727
1963
1937
839
2041
2010
943
2098
2063
1145
2242
2198

517
1886
1867
568
1928
1906
614
1950
1926
709
2027
1999
798
2085
2053
970
2232
2191

441
1866
1848
484
1905
1885
524
1925
1903
606
1997
1970
683
2051
2021
831
2187
2149

379
1849
1832
417
1885
1866
452
1904
1883
523
1971
1946
590
2021
1993
719
2148
2112

329
1834
1818
362
1868
1850
392
1885
1866
455
1948
1925
514
1995
1968
627
2113
2080

287
1821
1806
316
1853
1836
343
1869
1851
399
1928
1906
451
1971
1947
551
2083
2052

Maximum
Unshored
Span
16

3 Hour Fire Rating

Number of spans
2

Gage

22
21
20

6' - 10"
7' - 8"
8' - 1"

7' - 7"
8' - 6"
9' - 0"

Vertical Load Span (ft-in)


9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"

252
1809
1795
278
1839
1823
302
1854
1837
352
1910
1889
398
1951
1928
487
2056
2026

222
1805
1792
246
1835
1820
267
1851
1835
312
1907
1888
353
1950
1928
433
2059
2031

197
1795
1783
218
1824
1809
238
1839
1823
278
1892
1873
315
1932
1911
387
2036
2009

175
1786
1774
194
1814
1800
212
1828
1813
248
1878
1861
283
1916
1897
348
2015
1989

156
1778
1767
174
1804
1791
190
1817
1803
223
1866
1849
254
1902
1883
313
1996
1972

140
1771
1760
156
1796
1783
171
1808
1795
201
1854
1838
229
1889
1871
283
1978
1955

125
1764
1754
140
1788
1776
154
1800
1787
181
1844
1828
207
1877
1860
257
1962
1940

Number of spans
2

Gage

8' - 1"
8' - 11"
9' - 3"

19
18
16

9' - 3"
9' - 11"
10' - 7"

10' - 1"
10' - 9"
11' - 11"

113
1763
1753
126
1787
1775
139
1799
1787
164
1845
1830
188
1879
1862
234
1968
1947

101
1757
1747
114
1780
1769
125
1792
1780
149
1835
1821
171
1868
1852
213
1954
1934
3

10' - 5"
11' - 2"
12' - 4"

Preformed Metal Floor Deck

ASCSteel Deck

2W-36 Composite Floor Deck


2W-36 Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)
Total Slab Thickness: 4
Gage

22
21
20
19
18
16

Slab Weight: 36.2 psf

No. of
Spans

6'-0"

6'-6"

7'-0"

7'-6"

8'-0"

8'-6"

1, 2 or 3
36/4
36/3
1, 2 or 3
36/4
36/3
1, 2 or 3
36/4
36/3
1, 2 or 3
36/4
36/3
1, 2 or 3
36/4
36/3
1, 2 or 3
36/4
36/3

315
1405
1383
347
1446
1422
375
1468
1442
434
1544
1513
487
1600
1565
592
1742
1698

264
1392
1372
292
1433
1411
315
1454
1430
365
1530
1502
411
1587
1555
500
1732
1691

224
1372
1354
247
1410
1389
268
1430
1407
311
1500
1473
350
1553
1523
427
1686
1648

191
1355
1338
212
1390
1371
229
1408
1388
267
1474
1449
301
1523
1495
368
1647
1612

165
1340
1324
183
1373
1355
198
1390
1370
231
1451
1427
261
1496
1470
320
1613
1579

143
1327
1312
159
1357
1340
172
1373
1355
201
1431
1409
228
1473
1449
280
1582
1551

Maximum
Unshored
Span

Vertical Load Span (ft-in)


9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6"

Number of spans
2

Gage

22
21
20

7' - 5"
8' - 4"
8' - 9"

8' - 1"
9' - 2"
9' - 8"

124
1315
1301
138
1344
1328
151
1359
1341
177
1413
1392
200
1453
1429
246
1555
1526

108
1311
1297
121
1340
1325
132
1355
1339
155
1410
1390
177
1452
1429
218
1558
1530

95
1301
1288
107
1329
1314
117
1343
1327
137
1395
1376
157
1434
1413
194
1535
1508

84
1292
1280
94
1318
1304
103
1332
1317
122
1381
1363
140
1418
1398
173
1514
1489

74
1284
1272
83
1309
1296
91
1322
1308
108
1369
1352
125
1404
1385
155
1495
1471

65
1277
1265
74
1300
1288
81
1313
1299
97
1357
1341
112
1391
1373
139
1478
1455

57
1270
1259
65
1293
1280
72
1304
1291
86
1347
1331
100
1379
1362
125
1462
1440

Number of spans
2

Gage

8' - 10"
9' - 8"
10' - 1"

19
18
16

10' - 1"
10' - 8"
11' - 4"

10' - 11"
11' - 8"
12' - 11"

13'-0"

51
1269
1258
58
1292
1280
64
1304
1291
77
1348
1333
90
1381
1364
113
1468
1447

45
1263
1253
51
1285
1274
57
1296
1284
69
1338
1324
81
1370
1354
103
1453
1433
3

11' - 3"
12' - 1"
13' - 4"

2W-36 Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)
Total Slab Thickness: 5 1/2
Gage

22
21
20
19
18
16

1 Hour Fire Rating

Slab Weight: 54.7 psf

No. of
Spans

6'-0"

6'-6"

7'-0"

7'-6"

8'-0"

8'-6"

1, 2 or 3
36/4
36/3
1, 2 or 3
36/4
36/3
1, 2 or 3
36/4
36/3
1, 2 or 3
36/4
36/3
1, 2 or 3
36/4
36/3
1, 2 or 3
36/4
36/3

523
2310
2289
576
2352
2327
623
2373
2347
722
2449
2418
814
2506
2471
993
2647
2603

440
2297
2278
484
2338
2316
525
2359
2336
609
2436
2407
687
2493
2460
839
2637
2596

373
2277
2259
412
2315
2295
447
2335
2313
519
2405
2379
587
2458
2428
718
2592
2554

320
2260
2243
353
2296
2276
384
2314
2293
447
2379
2354
505
2428
2400
620
2552
2517

276
2245
2229
305
2278
2260
332
2295
2276
387
2356
2333
439
2402
2376
539
2518
2485

239
2232
2217
266
2263
2246
289
2279
2260
338
2336
2314
384
2379
2354
473
2488
2456

Maximum
Unshored
Span
December 2013

Number of spans
2

Gage

22
21
20

6' - 6"
7' - 3"
7' - 8"

7' - 3"
8' - 2"
8' - 6"

Vertical Load Span (ft-in)


9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"

209
2220
2206
232
2249
2233
253
2264
2247
297
2318
2297
338
2358
2335
417
2461
2431

183
2216
2203
204
2245
2230
223
2261
2244
262
2316
2296
299
2357
2335
370
2463
2436

161
2206
2194
180
2234
2219
197
2248
2233
232
2300
2282
266
2340
2319
329
2440
2414

142
2197
2185
159
2224
2210
175
2237
2223
207
2287
2269
237
2324
2304
295
2419
2394

126
2189
2178
141
2214
2201
156
2227
2213
185
2274
2257
212
2309
2290
265
2400
2376

99
2175
2165
112
2198
2186
124
2210
2197
148
2252
2237
171
2284
2267
215
2367
2345

Number of spans
2

Gage

7' - 8"
8' - 5"
8' - 10"

19
18
16

8' - 9"
9' - 6"
10' - 1"

www.ascsd.com

112
2182
2171
126
2206
2193
139
2218
2205
165
2263
2247
190
2296
2278
238
2383
2360

9' - 7"
10' - 3"
11' - 4"

88
2174
2164
100
2197
2185
111
2209
2197
133
2253
2238
155
2286
2270
195
2373
2352

78
2168
2158
89
2190
2179
99
2202
2190
120
2244
2229
140
2276
2260
177
2359
2338
3

9' - 11"
10' - 7"
11' - 9"
17

ASCSteel Deck

2W-36 Composite Floor Deck


2W-36 Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)
Total Slab Thickness: 6 1/2
Gage

22
21
20
19
18
16

2 Hour Fire Rating

Slab Weight: 67 psf

No. of
Spans

6'-0"

6'-6"

7'-0"

7'-6"

8'-0"

8'-6"

1, 2 or 3
36/4
36/3
1, 2 or 3
36/4
36/3
1, 2 or 3
36/4
36/3
1, 2 or 3
36/4
36/3
1, 2 or 3
36/4
36/3
1, 2 or 3
36/4
36/3

673
2914
2892
741
2955
2931
802
2977
2951
931
3053
3022
1051
3109
3074
1285
3251
3207

566
2901
2881
623
2942
2920
676
2963
2939
786
3039
3011
888
3096
3064
1087
3241
3200

481
2881
2863
530
2919
2898
576
2939
2916
670
3009
2982
758
3062
3032
930
3195
3157

412
2864
2847
455
2899
2880
495
2917
2897
577
2983
2958
654
3032
3004
803
3156
3121

356
2849
2833
394
2882
2864
429
2899
2879
501
2960
2937
568
3005
2979
700
3122
3088

309
2836
2821
343
2866
2849
374
2882
2864
438
2940
2918
497
2982
2958
614
3091
3060

Maximum
Unshored
Span

Vertical Load Span (ft-in)


9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6"

Number of spans
2

Gage

22
21
20

6' - 1"
6' - 9"
7' - 1"

6' - 10"
7' - 7"
7' - 11"

270
2824
2810
300
2853
2837
328
2868
2850
385
2922
2901
438
2962
2938
542
3064
3035

237
2820
2806
264
2849
2834
289
2864
2848
340
2919
2900
388
2961
2938
481
3067
3039

209
2810
2797
233
2838
2823
256
2852
2836
302
2904
2885
345
2943
2922
429
3044
3017

185
2801
2789
207
2827
2813
227
2841
2826
269
2890
2872
308
2927
2907
384
3023
2998

164
2793
2781
184
2818
2805
202
2831
2817
240
2878
2861
276
2913
2894
345
3004
2980

146
2786
2774
164
2809
2797
181
2822
2808
215
2866
2850
248
2900
2882
311
2987
2964

129
2779
2768
146
2802
2789
162
2813
2800
193
2856
2840
224
2888
2871
281
2971
2949

Number of spans
2

Gage

7' - 2"
7' - 10"
8' - 2"

19
18
16

8' - 2"
8' - 11"
9' - 6"

8' - 11"
9' - 6"
10' - 7"

13'-0"

115
2778
2767
131
2801
2789
145
2813
2800
174
2857
2842
202
2890
2873
255
2977
2956

103
2772
2762
117
2794
2783
130
2805
2793
157
2847
2833
183
2879
2863
232
2962
2942
3

9' - 3"
9' - 10"
10' - 11"

2W-36 Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)
Total Slab Thickness: 7 1/4
Gage

22
21
20
19
18
16

Slab Weight: 76.3 psf

No. of
Spans

6'-0"

6'-6"

7'-0"

7'-6"

8'-0"

8'-6"

1, 2 or 3
36/4
36/3
1, 2 or 3
36/4
36/3
1, 2 or 3
36/4
36/3
1, 2 or 3
36/4
36/3
1, 2 or 3
36/4
36/3
1, 2 or 3
36/4
36/3

788
3366
3345
868
3408
3384
940
3429
3404
1092
3506
3475
1234
3562
3527
1512
3704
3659

663
3354
3334
731
3395
3372
793
3416
3392
922
3492
3463
1043
3549
3517
1279
3693
3653

563
3334
3316
622
3372
3351
675
3391
3369
787
3462
3435
891
3514
3484
1095
3648
3610

483
3317
3300
534
3352
3332
581
3370
3349
678
3435
3411
769
3484
3456
946
3609
3573

418
3302
3286
462
3335
3316
503
3351
3332
588
3413
3389
668
3458
3432
824
3574
3541

363
3288
3273
403
3319
3302
439
3335
3317
514
3392
3370
585
3435
3410
723
3544
3513

Maximum
Unshored
Span
18

3 Hour Fire Rating

Number of spans
2

Gage

22
21
20

5' - 10"
6' - 6"
6' - 9"

6' - 7"
7' - 3"
7' - 7"

Vertical Load Span (ft-in)


9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" 13'-0"

318
3276
3262
353
3306
3289
385
3320
3303
452
3374
3354
516
3414
3391
639
3517
3487

279
3272
3259
311
3302
3286
340
3317
3301
400
3372
3352
457
3413
3391
567
3520
3492

246
3263
3250
275
3290
3276
301
3305
3289
355
3357
3338
407
3396
3375
506
3497
3470

218
3254
3242
244
3280
3266
268
3294
3279
317
3343
3325
363
3380
3360
453
3476
3451

193
3246
3234
217
3271
3257
239
3284
3269
283
3330
3313
326
3366
3347
408
3457
3433

172
3238
3227
193
3262
3249
213
3274
3261
254
3319
3303
293
3353
3334
368
3439
3416

153
3232
3221
173
3254
3242
191
3266
3253
229
3309
3293
264
3341
3323
333
3424
3401

Number of spans
2

Gage

6' - 10"
7' - 6"
7' - 10"

19
18
16

7' - 9"
8' - 6"
9' - 2"

8' - 6"
9' - 1"
10' - 1"

136
3230
3220
155
3253
3242
172
3265
3253
206
3309
3294
239
3343
3326
302
3429
3408

122
3224
3215
139
3247
3235
154
3258
3246
186
3300
3286
217
3332
3316
275
3415
3395
3

8' - 10"
9' - 5"
10' - 5"

Preformed Metal Floor Deck

ASCSteel Deck

2W Superimposed Load with Studs at Supports


Allowable Superimposed Load (psf) for 2W Deck When 3/4 Diameter Studs are used at the Supporting Beams
Concrete
Slab & Type
Thickness

4 1/2 LTWT

5 1/4 LTWT

6 1/2 LTWT

4 1/2 NWT

5 1/2 NWT

6 1/2 NWT

22
20
18
16
22
20
18
16
22
20
18
16
22
20
18
16
22
20
18
16
22
20
18
16

Studs at 10 OC

Studs at 30 OC

Span

Span

60

70

80

90

100

110

120

60

70

80

90

100

110

120

400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400

320
390
400
400
395
400
400
400
400
400
400
400
315
385
400
400
400
400
400
400
400
400
400
400

240
295
370
370
295
360
400
400
385
400
400
400
230
285
375
400
305
375
400
400
375
400
400
400

185
225
295
330
225
280
370
400
295
370
400
400
175
220
290
360
230
290
385
400
285
360
400
400

145
180
235
265
175
220
295
360
235
290
390
400
135
170
230
285
180
225
305
385
225
280
380
400

115
145
180
195
140
175
235
300
185
235
315
400
105
135
185
230
140
180
245
310
175
225
305
390

90
115
140
150
115
145
195
235
150
190
260
330
85
110
150
190
110
145
200
255
140
180
250
320

345
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400
400

245
280
390
400
305
335
400
400
400
400
400
400
290
290
390
400
380
380
400
400
400
400
400
400

180
195
280
360
260
230
340
400
345
295
400
400
215
215
275
360
280
280
340
400
350
400
390
400

16
135
205
270
200
170
245
325
260
330
290
400
165
160
200
265
215
265
235
325
265
325
260
375

125
155
155
205
155
195
175
240
200
255
200
290
125
160
140
195
165
205
285
235
205
250
355
255

100
125
115
155
120
155
210
180
155
200
280
205
100
125
175
145
130
165
230
290
160
195
280
360

80
105
140
120
95
125
175
130
120
160
230
290
80
105
140
180
100
130
185
235
125
155
225
295

1. See 2W tables for shoring requirements.


2. SLAB thickness is the total slab thickness.

December 2013

www.ascsd.com

19

ASCSteel Deck

3W Composite Floor Deck


12

3W - Allowable Reactions (plf)


Bearing Length

4-3/4

Gage

22
3

21

4-3/4
36

20
19

3W - Section Properties
Weight

S+

18

S--

Gage

(psf)

(In4)

(In3)

(In3)

22
21
20
19
18
16

1.68
1.83
2.04
2.29
2.70
3.36

0.769
0.881
0.938
1.126
1.260
1.582

0.433
0.511
0.550
0.692
0.780
0.976

0.471
0.540
0.574
0.694
0.777
0.975

16

1 1/2

2 1/2

3 1/2

155
402
232
539
275
615
452
918
602
1170
1042
1898

175
441
259
586
306
666
495
983
655
1246
1117
1998

195
488
286
630
337
717
539
1049
707
1322
1193
2099

215
550
313
704
367
787
582
1114
760
1398
1268
2200

235
611
340
778
398
867
626
1208
813
1479
1344
2300

255
673
367
852
429
948
669
1311
866
1598
1419
2401

275
734
395
927
459
1028
713
1414
919
1717
1495
2538

1. The top value reflects the allowable reaction at the panel end supports.
(prior to concrete cure)
2. The bottom value reflects the allowable reaction at the interior supports.
(prior to concrete cure)
3. Values are in pounds per linear foot.

3W Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Lightweight Concrete (110 pcf)
Total Slab Thickness: 5
No. of
Gage Spans

22

21

20

19

18

16

1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4

Slab Weight: 32.0 psf

Span

80

86

90

96

100

106

110

116

120

126

130

136

140

146

150

249
249
249
1281
1372
272
272
272
1281
1399
283
283
283
1283
1414
320
320
320
1296
1471
345
345
345
1310
1517
403
403
403
1356
1636

228
228
228
1269
1351
248
248
248
1267
1374
258
258
258
1268
1388
292
292
292
1279
1440
315
315
315
1291
1482
368
368
368
1332
1592

209
209
209
1259
1332
228
228
228
1255
1353
237
237
237
1256
1365
268
268
268
1263
1413
289
289
289
1274
1452
338
338
338
1310
1554

193
193
193
1249
1315
210
210
210
1245
1333
218
218
218
1244
1344
247
247
247
1250
1388
267
267
267
1259
1424
312
312
312
1291
1519

151
178
178
1241
1299
194
194
194
1235
1316
202
202
202
1234
1326
229
229
229
1237
1366
247
247
247
1245
1399
287
287
287
1274
1488

139
166
166
1233
1285
181
181
181
1226
1300
188
188
188
1225
1309
213
213
213
1226
1346
230
230
230
1232
1377
258
258
258
1258
1460

128
149
149
1226
1273
141
169
169
1218
1286
169
175
175
1216
1294
198
198
198
1216
1328
214
214
214
1221
1356
232
232
232
1244
1434

118
118
133
1220
1261
131
155
155
1211
1273
137
164
164
1208
1280
186
186
186
1207
1311
200
200
200
1211
1338
209
209
209
1231
1411

109
109
120
1214
1251
121
139
139
1204
1261
127
149
149
1201
1267
167
174
174
1198
1296
188
188
188
1201
1320
189
189
189
1219
1389

101
101
101
1208
1241
112
112
126
1198
1250
117
117
134
1195
1255
145
164
164
1191
1282
171
177
177
1192
1305
172
172
172
1208
1369

93
93
93
1203
1232
104
104
113
1193
1239
109
109
122
1189
1245
127
150
150
1183
1269
150
167
167
1184
1290
156
156
156
1198
1351

87
87
87
1199
1224
97
97
97
1187
1230
102
102
110
1183
1235
118
136
136
1177
1257
130
154
154
1177
1277
142
142
142
1189
1334

81
81
81
1195
1216
90
90
90
1182
1221
95
95
95
1178
1225
110
110
124
1171
1246
121
141
140
1170
1264
129
129
129
1180
1319

74
74
74
1191
1209
84
84
84
1178
1213
89
89
89
1173
1217
103
103
113
1165
1235
114
114
128
1164
1253
122
122
122
1172
1304

68
68
68
1187
1202
79
79
79
1174
1205
83
83
83
1169
1209
97
97
97
1159
1225
106
106
117
1158
1242
112
112
112
1164
1290

1. In shaded areas, mid-span deck shoring required during construction.


2. q3 and q4 q=allowable diaphragm shear (plf): 3, 4=number of welds to support.
3. See pg. 55 for General Notes.

20

Preformed Metal Floor Deck

ASCSteel Deck

3W Composite Floor Deck


3W Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Lightweight Concrete (110 pcf)
Total Slab Thickness: 5
No. of
Gage Spans

22

21

20

19

18

16

1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4

Slab Weight: 32.0 psf


Span

80

86

90

96

100

106

110

116

120

126

130

136

140

146

150

273
273
273
1439
1530
297
297
297
1439
1557
309
309
309
1441
1571
348
348
348
1454
1629
375
375
375
1468
1675
437
437
437
1514
1794

249
249
249
1427
1509
271
271
271
1426
1532
282
282
282
1426
1546
318
318
318
1437
1598
343
343
343
1449
1640
399
399
399
1490
1750

229
229
229
1417
1490
249
249
249
1413
1511
259
259
259
1414
1523
292
292
292
1421
1571
315
315
315
1432
1610
366
366
366
1468
1712

211
211
211
1407
1473
230
230
230
1403
1491
239
239
239
1402
1502
269
269
269
1408
1546
290
290
290
1417
1582
338
338
338
1449
1677

165
195
195
1399
1457
213
213
213
1393
1474
221
221
221
1392
1484
249
249
249
1395
1524
269
269
269
1403
1557
313
313
313
1432
1646

151
181
181
1391
1443
195
198
198
1384
1453
205
205
205
1383
1467
232
232
232
1384
1504
250
250
250
1390
1535
291
291
291
1416
1618

139
139
169
1384
1431
153
184
184
1376
1444
161
192
192
1374
1452
216
216
216
1374
1486
233
233
233
1379
1514
271
271
271
1402
1592

128
128
152
1378
1419
142
172
172
1369
1431
148
179
179
1366
1438
202
202
202
1365
1469
218
218
218
1369
1496
253
253
253
1389
1569

118
118
118
1372
1409
131
131
159
1362
1419
137
137
168
1359
1425
179
190
190
1356
1454
204
204
204
1359
1478
238
238
238
1377
1547

109
109
109
1366
1399
121
121
143
1356
1408
127
127
154
1353
1413
149
178
178
1349
1440
184
192
192
1350
1463
224
224
224
1366
1527

101
101
101
1361
1390
113
113
113
1351
1397
118
118
139
1347
1403
137
168
168
1341
1427
150
181
181
1342
1448
211
211
211
1356
1509

94
94
94
1357
1382
105
105
105
1345
1388
110
110
110
1341
1393
128
128
156
1335
1415
140
171
171
1335
1435
199
199
199
1347
1492

87
87
87
1353
1374
97
97
97
1340
1379
102
102
102
1336
1383
119
119
142
1329
1404
131
131
162
1328
1422
157
189
189
1338
1477

81
81
81
1349
1367
91
91
91
1336
1371
96
96
96
1331
1375
111
111
111
1323
1393
122
122
148
1322
1411
147
179
179
1330
1462

76
76
76
1345
1360
85
85
85
1332
1363
89
89
89
1327
1366
104
104
104
1317
1383
115
115
135
1316
1400
138
170
170
1322
1448

1. In shaded areas, mid-span deck shoring required during construction.


2. q3 and q4 q=allowable diaphragm shear (plf): 3, 4=number of welds to support.
3. See pg. 55 for General Notes.

December 2013

www.ascsd.com

21

ASCSteel Deck

3W Composite Floor Deck


3W Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Lightweight Concrete (110 pcf)
Total Slab Thickness: 6 1/4
No. of
Gage Spans

22

21

20

19

18

16

1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4

2 Hour Fire Rating

Slab Weight:43.6 psf


Span

80

86

90

96

100

106

110

116

120

126

130

136

140

146

150

311
311
311
1676
1767
338
338
338
1676
1794
352
352
352
1678
1808
396
396
396
1691
1866
426
426
426
1705
1912
494
494
494
1751
2031

284
284
284
1664
1746
309
309
309
1662
1769
321
321
321
1663
1783
361
361
361
1674
1835
389
389
389
1686
1877
451
451
451
1727
1987

261
261
261
1654
1726
284
284
284
1650
1748
295
295
295
1650
1760
332
332
332
1658
1808
357
357
357
1669
1847
414
414
414
1705
1949

205
241
241
1644
1709
262
262
262
1640
1728
272
272
272
1639
1739
306
306
306
1645
1783
329
329
329
1654
1819
382
382
382
1686
1914

187
223
223
1636
1694
206
242
242
1630
1711
252
252
252
1629
1721
283
283
283
1632
1761
305
305
305
1640
1794
353
353
353
1669
1883

171
171
207
1628
1680
189
225
225
1621
1695
198
234
234
1620
1704
263
263
263
1621
1741
283
283
283
1627
1772
328
328
328
1653
1885

157
157
193
1621
1668
174
210
210
1613
1681
182
218
218
1611
1689
245
245
245
1611
1723
264
264
264
1616
1751
306
306
306
1639
1829

145
145
145
1615
1656
160
160
196
1606
1668
168
168
204
1603
1675
227
230
230
1602
1706
247
247
247
1606
1733
287
287
287
1626
1806

133
133
133
1609
1646
148
148
184
1599
1656
155
155
191
1596
1662
179
215
215
1593
1691
232
232
232
1596
1715
269
269
269
1614
1784

123
123
123
1603
1636
137
137
137
1593
1644
144
144
180
1590
1650
166
166
203
1586
1677
181
218
218
1587
1700
253
253
253
1603
1764

114
114
114
1598
1627
127
127
127
1587
1634
133
133
133
1584
1639
154
154
191
1578
1664
169
206
206
1579
1685
238
238
238
1593
1746

106
106
106
1594
1619
118
118
118
1582
1625
124
124
124
1578
1629
144
144
181
1572
1652
157
157
194
1572
1672
188
225
225
1584
1729

98
98
98
1589
1611
110
110
110
1577
1616
115
115
115
1573
1620
134
134
134
1565
1641
147
147
184
1565
1659
176
213
213
1575
1714

91
91
91
1586
1604
102
102
102
1573
1608
108
108
108
1568
1612
125
125
125
1560
1630
137
137
137
1559
1648
165
202
202
1567
1699

85
85
85
1582
1597
95
95
95
1569
1600
100
100
100
1564
1603
117
117
117
1554
1620
129
129
129
1553
1637
155
155
192
1559
1685

1. In shaded areas, mid-span deck shoring required during construction.


2. q3 and q4 q=allowable diaphragm shear (plf): 3, 4=number of welds to support.
3. See pg. 55 for General Notes.

22

Preformed Metal Floor Deck

ASCSteel Deck

3W Composite Floor Deck


3W Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Lightweight Concrete (110 pcf)
Total Slab Thickness: 7 3/16
No. of
Gage Spans

22

21

20

19

18

16

1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4

3 Hour Fire Rating

Slab Weight:52.1 psf


Span

80

86

90

96

100

106

110

116

120

126

130

136

140

146

150

363
363
363
1972
2063
394
394
394
1972
2090
409
409
409
1974
2105
460
460
460
1987
2163
494
494
494
2001
2208
571
571
571
2047
2327

288
331
331
1960
2042
360
360
360
1958
2065
373
373
373
1959
2079
420
420
429
1970
2132
451
451
451
1982
2174
522
522
522
2023
2284

261
304
304
1950
2023
330
330
330
1946
2044
343
343
343
1947
2056
385
385
385
1954
2104
414
414
414
1965
2143
479
479
479
2001
2245

237
280
280
1940
2006
261
304
304
1936
2024
316
316
316
1935
2035
355
355
355
1941
2079
382
382
382
1950
2115
442
442
442
1982
2210

217
217
259
1932
1990
239
282
282
1926
2007
250
293
293
1925
2017
329
329
329
1928
2057
353
353
353
1936
2090
409
409
409
1965
2179

198
198
241
1924
1976
219
219
262
1917
1991
229
272
272
1916
2000
306
306
306
1917
2037
328
328
328
1923
2068
380
380
380
1949
2151

182
182
182
1917
1964
201
201
244
1909
1977
210
210
254
1907
1985
285
285
285
1907
2019
306
306
306
1912
2047
354
354
354
1935
2125

167
167
167
1911
1952
185
185
228
1902
1964
194
194
237
1900
1971
223
267
267
1898
2002
287
287
287
1902
2029
332
332
332
1922
2102

154
154
154
1905
1942
171
171
171
1895
1952
179
179
179
1893
1958
207
207
250
1890
1987
225
269
269
1892
2012
311
311
311
1910
2080

143
143
143
1900
1932
159
159
159
1889
1941
166
166
166
1886
1947
192
192
235
1882
1973
209
209
253
1884
1996
293
293
293
1899
2061

132
132
132
1895
1923
147
147
147
1884
1930
154
154
154
1880
1936
178
178
178
1875
1960
195
195
238
1876
1981
232
276
276
1889
2040

122
122
122
1890
1915
136
136
136
1878
1921
143
143
143
1875
1926
166
166
166
1868
1948
182
182
225
1868
1968
216
261
261
1880
2025

114
114
114
1886
1907
127
127
127
1874
1912
133
133
133
1869
1916
155
155
155
1862
1937
170
170
170
1861
1955
202
202
247
1871
2010

105
105
105
1882
1900
118
118
118
1869
1904
124
124
124
1865
1908
145
145
145
1856
1926
159
159
159
1855
1944
190
190
234
1863
1995

98
98
98
1878
1893
110
110
110
1865
1897
116
116
116
1860
1900
135
135
135
1851
1917
149
149
149
1849
1933
178
178
178
1855
1982

1. In shaded areas, mid-span deck shoring required during construction.


2. q3 and q4 q=allowable diaphragm shear (plf): 3, 4=number of welds to support.
3. See pg. 55 for General Notes.

December 2013

www.ascsd.com

23

ASCSteel Deck

3W Composite Floor Deck


3W Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)
Total Slab Thickness: 5 Slab Weight: 42.3 psf
No. of
Gage Spans

22

21

20

19

18

16

1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4

Span
80

86

90

96

100

106

110

116

120

126

130

136

140

146

150

249
249
249
1605
1696
272
272
272
1605
1723
283
283
283
1607
1738
320
320
320
1620
1796
345
345
345
1635
1842
403
403
403
1680
1960

228
228
228
1594
1675
248
248
248
1592
1699
258
258
258
1593
1712
292
292
292
1603
1765
315
315
315
1615
1807
368
368
368
1656
1917

209
209
209
1583
1656
228
228
228
1580
1677
237
237
237
1580
1689
268
268
268
1588
1737
289
289
289
1598
1776
338
338
338
1635
1878

158
193
193
1574
1639
210
210
210
1569
1658
218
218
218
1569
1669
247
247
247
1574
1713
267
267
267
1583
1748
312
312
312
1616
1843

143
178
178
1565
1624
159
194
194
1559
1640
197
202
202
1558
1650
229
229
229
1562
1690
247
247
247
1569
1724
289
289
289
1598
1812

131
131
159
1557
1610
145
181
181
1551
1624
153
188
188
1549
1633
213
213
213
1551
1670
230
230
230
1557
1701
260
260
260
1583
1784

120
120
141
1550
1597
133
165
165
1543
1610
140
175
175
1541
1618
189
198
198
1541
1652
214
214
214
1545
1681
233
233
233
1568
1758

110
110
110
1544
1586
122
122
147
1535
1597
129
129
157
1533
1604
160
186
186
1531
1635
192
200
200
1535
1662
209
209
209
1555
1735

101
101
101
1538
1575
113
113
131
1529
1585
118
118
141
1526
1592
138
174
174
1523
1620
165
188
188
1526
1645
189
189
189
1543
1714

92
92
92
1533
1565
104
104
104
1523
1574
109
109
126
1519
1580
128
128
156
1515
1606
141
177
177
1517
1629
170
170
170
1533
1694

85
85
85
1528
1556
96
96
96
1517
1564
101
101
101
1513
1569
119
119
141
1508
1593
131
160
160
1509
1615
153
153
153
1522
1676

78
78
78
1523
1548
89
89
89
1512
1554
93
93
93
1508
1559
110
110
127
1501
1581
121
121
145
1501
1601
143
141
141
1513
1659

72
72
72
1519
1540
82
82
82
1507
1546
87
87
87
1503
1550
102
102
102
1495
1570
113
113
131
1494
1589
131
128
128
1504
1643

67
67
67
1515
1533
76
76
76
1502
1537
80
80
80
1498
1541
95
95
95
1489
1560
105
105
105
1488
1577
119
116
116
1496
1628

60
60
60
1511
1527
70
70
70
1498
1530
74
74
74
1493
1533
89
89
89
1484
1550
98
98
98
1482
1566
109
109
105
1489
1615

1. In shaded areas, mid-span deck shoring required during construction.


2. q3 and q4 q=allowable diaphragm shear (plf): 3, 4=number of welds to support.
3. See pg. 55 for General Notes.

24

Preformed Metal Floor Deck

ASCSteel Deck

3W Composite Floor Deck


3W Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)
Total Slab Thickness: 5 1/2 Slab Weight: 48.3 psf
No. of
Gage Spans

22

21

20

19

18

16

1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4

Span
80

86

90

96

100

106

110

116

120

126

130

136

140

146

150

273
273
273
1845
1936
297
297
297
1844
1962
309
309
309
1846
1977
348
348
348
1859
2035
375
375
375
1874
2081
437
437
439
1919
2199

249
249
249
1833
1914
271
271
271
1831
1938
282
282
282
1832
1951
318
318
318
1842
2004
343
343
343
1854
2046
399
399
399
1895
2156

189
229
229
1822
1895
249
249
249
1819
1916
259
259
259
1819
1928
292
292
292
1827
1976
315
315
315
1837
2015
366
366
366
1874
2117

171
211
211
1813
1878
229
229
229
1808
1897
239
239
239
1808
1908
269
269
269
1813
1952
290
290
290
1822
1988
338
338
338
1855
2083

155
155
195
1804
1863
173
213
213
1798
1879
181
221
221
1797
1889
249
249
249
1801
1930
269
269
269
1808
1963
313
313
313
1837
2051

142
142
181
1797
1849
157
198
198
1790
1864
165
205
205
1788
1872
232
232
232
1790
1910
250
250
250
1796
1940
291
291
291
1822
2023

129
129
129
1790
1836
144
144
184
1782
1849
151
151
192
1780
1857
200
216
216
1780
1891
233
233
233
1785
1920
271
271
271
1807
1998

118
118
118
1783
1825
132
132
168
1774
1836
139
139
179
1772
1843
162
202
202
1770
1875
204
218
218
1774
1901
253
253
253
1794
1974

109
109
109
1777
1814
122
122
122
1768
1824
128
128
161
1765
1831
149
149
190
1762
1859
172
204
204
1765
1884
238
238
238
1783
1953

100
100
100
1772
1804
112
112
112
1762
1813
118
118
118
1755
1819
138
138
178
1754
1845
151
192
192
1756
1868
217
224
224
1772
1933

92
92
92
1767
1796
103
103
103
1756
1803
109
109
109
1752
1808
128
128
162
1747
1832
140
140
181
1748
1854
169
211
211
1762
1915

84
84
84
1762
1787
95
95
95
1751
1793
101
101
101
1747
1798
118
118
118
1740
1820
130
130
168
1741
1840
158
199
199
1752
1898

78
79
78
1758
1780
88
88
88
1746
1785
93
93
93
1742
1789
110
110
110
1734
1809
121
121
121
1734
1828
147
147
189
1743
1882

72
72
72
1754
1772
81
81
81
1741
1777
86
86
86
1737
1780
102
102
102
1728
1799
113
113
113
1727
1816
138
138
179
1735
1868

66
66
66
1750
1766
75
75
75
1737
1769
80
80
80
1732
1772
95
95
95
1723
1789
105
105
105
1721
1805
129
129
164
1728
1854

1. In shaded areas, mid-span deck shoring required during construction.


2. q3 and q4 q=allowable diaphragm shear (plf): 3, 4=number of welds to support.
3. See pg. 55 for General Notes.

December 2013

www.ascsd.com

25

ASCSteel Deck

3W Composite Floor Deck


3W Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)
Total Slab Thickness: 6 1/2 1 Hour Fire Rating Slab Weight: 60.5 psf
No. of
Gage Spans

22

21

20

19

18

16

1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4

Span
80

86

90

96

100

106

110

116

120

126

130

136

140

146

150

325
325
325
2323
2414
353
353
353
2323
2440
367
367
367
2324
2455
412
412
412
2337
2513
443
443
443
2352
2559
514
514
514
2398
2678

247
296
295
2311
2392
322
322
322
2309
2416
335
335
335
2310
2429
377
377
377
2320
2482
405
405
405
2333
2524
469
469
469
2373
2634

223
272
272
2300
2373
246
296
296
2297
2394
307
307
307
2297
2406
346
346
346
2305
2455
372
372
372
2316
2493
431
431
431
2352
2595

202
202
251
2291
2356
223
273
273
2286
2375
234
283
283
2286
2386
319
319
319
2291
2430
343
343
343
2300
2466
397
397
397
2333
2561

183
183
183
2282
2341
203
203
253
2277
2357
213
262
262
2276
2367
295
295
295
2279
2408
317
317
317
2286
2441
368
368
368
2315
2530

166
166
166
2275
2327
185
185
235
2268
2342
194
194
244
2266
2351
224
274
274
2268
2388
295
295
295
2274
2418
342
342
342
2300
2501

152
152
152
2268
2314
169
169
169
2260
2327
178
178
227
2258
2335
206
256
256
2258
2369
263
275
275
2263
2398
319
319
319
2286
2476

139
139
139
2261
2303
155
155
155
2253
2314
163
163
163
2250
2322
189
189
239
2249
2353
207
257
257
2252
2379
298
298
298
2273
2452

127
127
127
2255
2292
142
142
142
2246
2302
150
150
150
2243
2309
174
174
224
2240
2337
191
191
241
2243
2362
278
278
278
2261
2431

117
117
117
2250
2283
131
131
131
2240
2291
138
138
138
2237
2297
161
161
161
2232
2323
177
177
227
2234
2346
212
263
263
2250
2411

107
107
107
2245
2274
121
121
121
2234
2281
127
127
127
2231
2286
149
149
149
2225
2310
164
164
164
2226
2332
197
248
248
2240
2393

98
98
98
2241
2265
111
111
111
2229
2272
117
117
117
2225
2276
138
138
138
2218
2298
152
152
152
2219
2318
183
183
234
2230
2376

91
91
91
2236
2258
103
103
103
2224
2263
108
108
108
2220
2267
128
128
128
2212
2287
141
141
141
2212
2306
171
171
222
2222
2360

83
83
83
2232
2251
95
95
95
2220
2255
100
100
100
2215
2258
119
119
119
2206
2277
131
131
131
2205
2294
159
159
159
2214
2346

77
77
77
2229
2244
87
87
87
2215
2247
93
93
93
2211
2250
110
110
110
2201
2267
122
122
122
2199
2284
149
149
149
2206
2332

1. In shaded areas, mid-span deck shoring required during construction.


2. q3 and q4 q=allowable diaphragm shear (plf): 3, 4=number of welds to support.
3. See pg. 55 for General Notes.

26

Preformed Metal Floor Deck

ASCSteel Deck

3W Composite Floor Deck


3W Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)
Total Slab Thickness: 7 1 1/2 Hour Fire Rating Slab Weight: 66.4 psf
No. of
Gage Spans

22

21

20

19

18

16

1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4

Span
80

86

90

96

100

106

110

116

120

126

130

136

140

146

150

298
352
352
2562
2653
383
383
383
2562
2679
397
397
397
2563
2694
447
447
447
2577
2752
480
480
480
2591
2798
556
556
556
2637
2917

267
321
321
2550
2631
349
349
349
2548
2655
363
383
363
2549
2668
408
408
408
2559
2721
438
438
438
2572
2763
507
507
507
2613
2873

241
241
295
2539
2612
266
321
321
2536
2633
278
333
333
2536
2645
374
374
374
2544
2694
402
402
402
2555
2732
466
466
466
2591
2834

218
218
272
2530
2595
241
296
296
2525
2614
252
307
307
2525
2625
345
345
345
2530
2669
371
371
371
2539
2705
429
429
429
2572
2800

198
198
198
2521
2580
219
219
274
2516
2597
230
230
284
2516
2606
320
320
320
2518
2647
343
343
343
2526
2680
397
397
397
2555
2769

180
180
180
2514
2566
200
200
254
2507
2581
210
210
264
2505
2590
242
297
297
2507
2627
319
319
319
2513
2657
369
369
369
2539
2740

164
164
164
2507
2554
183
183
183
2499
2566
192
192
192
2497
2574
222
222
277
2497
2609
243
298
298
2502
2637
345
345
345
2525
2715

150
150
150
2500
2542
167
167
167
2492
2553
176
176
176
2489
2561
204
204
259
2488
2592
223
223
278
2491
2618
322
322
322
2512
2691

137
137
137
2495
2531
154
154
154
2485
2541
162
162
162
2482
2548
188
188
188
2479
2577
206
206
261
2482
2601
247
302
302
2500
2670

126
126
126
2489
2522
141
141
141
2479
2530
149
149
149
2476
2536
174
174
174
2471
2563
191
191
246
2473
2586
229
284
284
2489
2650

115
115
115
2484
2513
130
130
130
2473
2520
137
137
137
2470
2525
161
161
161
2464
2550
176
176
176
2465
2571
212
212
268
2479
2632

106
106
106
2480
2504
120
120
120
2468
2511
126
126
120
2464
2515
149
149
149
2457
2538
164
164
164
2458
2558
198
198
253
2469
2615

97
97
97
2475
2497
110
110
110
2463
2502
117
117
117
2459
2506
138
138
138
2451
2526
152
152
152
2451
2545
184
184
184
2461
2599

90
90
90
2471
2490
102
102
102
2459
2494
108
108
108
2454
2497
128
128
128
2446
2516
141
141
141
2444
2533
172
172
172
2453
2585

82
82
82
2468
2483
94
94
94
2454
2486
100
100
100
2450
2489
119
119
119
2440
2506
132
132
132
2438
2523
160
160
160
2445
2571

1. In shaded areas, mid-span deck shoring required during construction.


2. q3 and q4 q=allowable diaphragm shear (plf): 3, 4=number of welds to support.
3. See pg. 55 for General Notes.

December 2013

www.ascsd.com

27

ASCSteel Deck

3W Composite Floor Deck


3W Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)
Total Slab Thickness: 7 1/2 2 Hour Fire Rating Slab Weight: 72.5 psf
No. of
Gage Spans

22

21

20

19

18

16

1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4

Span
80

86

90

96

100

106

110

116

120

126

130

136

140

146

150

321
380
380
2801
2892
413
413
413
2801
2919
429
429
429
2802
2933
482
482
482
2816
2991
517
517
517
2830
3037
598
598
598
2876
3156

288
347
347
2789
2870
318
377
377
2787
2894
391
391
391
2788
2908
440
440
440
2798
2960
473
473
473
2811
3002
546
546
546
2852
3112

260
260
319
2778
2851
287
346
346
2775
2872
300
359
359
2775
2885
404
404
404
2783
2933
434
434
434
2794
2971
502
502
502
2830
3074

235
235
235
2769
2834
260
260
319
2764
2853
272
331
331
2764
2864
372
372
372
2769
2908
400
400
400
2778
2944
462
462
462
2811
3039

213
213
213
2761
2819
236
236
295
2755
2836
247
247
307
2754
2846
285
345
345
2757
2886
370
370
370
2765
2919
428
428
428
2794
3008

194
194
194
2753
2805
215
215
215
2746
2820
226
226
285
2744
2829
261
261
320
2746
2866
284
344
344
2752
2897
398
398
398
2778
2979

177
177
177
2746
2793
197
197
197
2738
2806
206
206
206
2736
2814
239
239
299
2736
2848
261
261
321
2741
2876
371
371
371
2764
2954

161
161
161
2739
2781
180
180
180
2731
2792
189
189
189
2728
2800
220
220
279
2727
2831
240
240
300
2731
2857
347
347
347
2751
2930

148
148
148
2734
2771
165
165
165
2724
2780
174
174
174
2721
2787
202
202
202
2718
2816
222
222
282
2721
2840
265
326
326
2739
2909

135
135
135
2728
2761
152
152
152
2718
2769
160
160
160
2715
2775
187
187
187
2710
2802
205
205
205
2712
2825
246
246
306
2728
2889

124
124
124
2723
2752
140
140
140
2712
2759
147
147
147
2709
2764
173
173
173
2703
2789
190
190
190
2704
2810
228
228
289
2718
2871

114
114
114
2719
2744
129
129
129
2707
2750
136
136
136
2703
2754
160
160
160
2697
2777
176
176
176
2697
2797
212
212
212
2709
2854

105
105
105
2714
2736
119
119
119
2702
2741
126
126
126
2698
2745
148
148
148
2690
2765
163
163
163
2690
2784
198
198
198
2700
2838

96
96
96
2710
2729
110
110
110
2698
2733
116
116
116
2693
2736
137
137
137
2685
2755
152
152
152
2683
2773
185
185
185
2692
2824

88
88
88
2707
2722
101
101
101
2694
2725
107
107
107
2689
2728
128
128
128
2679
2745
141
141
141
2677
2762
172
172
172
2684
2810

1. In shaded areas, mid-span deck shoring required during construction.


2. q3 and q4 q=allowable diaphragm shear (plf): 3, 4=number of welds to support.
3. See pg. 55 for General Notes.

28

Preformed Metal Floor Deck

ASCSteel Deck

3W Composite Floor Deck


3W Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)
Total Slab Thickness: 8 1/4 3 Hour Fire Rating Slab Weight: 81.6 psf
No. of
Gage Spans

22

21

20

19

18

16

1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4
1
2
3
q3
q4

Span
80

86

357
320
423
320
423
386
3160 3148
3250 3229
393
353
459
419
459
419
3159 3146
3277 3253
477
369
477
435
477
435
3161 3147
3292 3266
536
489
536
489
536
489
3174 3157
3350 3319
575
525
575
525
575
525
3189 3169
3396 3361
665
607
665
607
665
607
3234 3210
3514 3471

90

96

100

106

110

116

120

126

130

136

140

146

150

288
288
288
3137
3210
319
319
385
3134
3231
333
400
400
3134
3243
449
449
449
3142
3291
482
482
482
3152
3330
557
557
557
3189
3432

261
261
261
3128
3193
289
289
355
3123
3212
302
302
368
3123
3223
347
414
414
3128
3267
445
445
445
3137
3302
514
514
514
3170
3398

236
236
236
3119
3178
262
262
262
3113
3194
275
275
341
3112
3204
316
316
383
3116
3245
345
412
412
3123
3278
476
476
476
3152
3366

215
215
215
3111
3164
239
239
239
3105
3179
251
251
251
3103
3187
289
289
356
3105
3224
315
383
383
3111
3255
442
442
442
3137
3338

196
196
196
3104
3151
218
218
218
3097
3164
229
229
229
3095
3172
265
265
332
3095
3206
290
290
357
3100
3235
412
412
412
3122
3312

179
179
179
3098
3140
200
200
200
3089
3151
210
210
210
3087
3158
244
244
244
3085
3190
267
267
334
3089
3216
318
386
386
3109
3289

164
164
164
3092
3129
183
183
183
3083
3139
193
193
193
3080
3146
225
225
225
3077
3174
246
246
246
3080
3199
294
294
362
3098
3268

150
150
150
3087
3119
169
169
169
3077
3128
177
177
177
3073
3134
207
207
207
3069
3160
227
227
227
3071
3183
272
272
340
3087
3248

138
138
138
3082
3111
155
155
155
3071
3118
163
163
163
3067
3123
192
192
192
3062
3147
210
210
210
3063
3169
253
253
253
3076
3230

126
126
126
3077
3102
143
143
143
3066
3108
151
151
151
3062
3113
177
177
177
3055
3135
195
195
195
3055
3155
235
235
235
3067
3213

116
116
116
3073
3095
132
132
132
3061
3100
139
139
139
3057
3104
164
164
164
3049
3124
181
181
181
3049
3143
219
219
219
3058
3197

107
107
107
3069
3087
121
121
121
3056
3091
128
128
128
3052
3095
152
152
152
3043
3114
168
168
168
3042
3131
204
204
204
3050
3182

98
98
98
3065
3081
112
112
112
3052
3084
119
119
119
3047
3087
141
141
141
3038
3104
157
157
157
3036
3120
191
191
191
3043
3169

1. In shaded areas, mid-span deck shoring required during construction.


2. q3 and q4 q=allowable diaphragm shear (plf): 3, 4=number of welds to support.
3. See pg. 55 for General Notes.

December 2013

www.ascsd.com

29

ASCSteel Deck

3WF Composite Floor Deck


12

3WF - Allowable Reactions (plf)


Bearing Length
Gage

4-3/4

20/20
20/18

20/16

4-3/4
36

18/20

3 Welds
4 Welds
Also available in 24 coverage

18/18

3WF - Section Properties


Weight

S+

S--

Gage

(psf)

(In4)

(In3)

(In3)

20/20
20/18
20/16
18/20
18/18
18/16
16/16

3.44
3.96
4.45
4.10
4.59
5.11
5.73

1.328
1.469
1.585
1.662
1.832
1.984
2.350

0.623
0.634
0.646
0.870
0.885
0.899
1.113

0.623
0.646
0.666
0.832
0.855
0.873
1.080

18/16
16/16

1 1/2

2 1/2

3 1/2

275
615
275
615
275
615
602
1170
502
1170
602
1170
1042
1898

306
666
306
666
306
666
655
1246
655
1246
655
1246
1117
1998

337
717
337
717
337
717
707
1322
707
1322
707
1322
1193
2099

367
787
367
787
367
787
760
1398
760
1398
760
1398
1268
2200

398
867
398
867
398
867
813
1479
813
1479
813
1479
1344
2300

429
948
429
948
429
948
866
1598
866
1598
866
1598
1419
2401

459
1028
459
1028
459
1028
919
1717
919
1717
919
1717
1495
2538

1. The top value reflects the allowable reaction at the panel end supports.
(prior to concrete cure)
2. The bottom value reflects the allowable reaction at the interior supports.
(prior to concrete cure)
3. Values are in pounds per linear foot.

3WF Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Lightweight Concrete (110 pcf)
Total Slab Thickness: 5 Slab Weight: 32.0 psf
No. of
Gage Spans

20/20

20/18

20/16

18/20

18/18

18/16

16/16

1
2
3
q3
1
2
3
q3
1
2
3
q3
1
2
3
q3
1
2
3
q3
1
2
3
q3
1
2
3
q3

Span

80

86

90

96

100

106

110

116

120

126

130

136

140

146

150

307
307
307
1353
309
309
309
1408
295
295
295
1470
371
371
371
1389
363
363
363
1449
350
350
350
1514
399
399
399
1559

280
280
280
1329
282
282
282
1380
270
270
270
1436
339
339
339
1362
331
331
331
1417
319
319
319
1477
364
364
364
1519

257
257
257
1308
259
259
259
1354
247
247
247
1406
311
311
311
1338
304
304
304
1388
293
293
293
1444
334
334
334
1483

237
237
237
1289
239
239
239
1331
228
228
228
1380
287
287
287
1316
280
280
280
1363
270
270
270
1414
308
308
308
1451

220
220
220
1272
221
221
221
1310
211
211
211
1355
265
265
265
1297
260
260
260
1340
250
250
250
1388
285
285
285
1422

204
204
204
1256
206
206
206
1292
196
196
196
1334
247
247
247
1279
241
241
241
1319
233
233
233
1364
265
265
265
1396

191
191
191
1242
192
192
192
1275
183
183
183
1314
230
230
230
1263
225
225
225
1300
217
217
217
1342
247
247
247
1372

178
178
178
1230
179
179
179
1259
171
171
171
1296
215
215
215
1249
210
210
210
1283
203
203
203
1322
231
231
231
1351

167
167
167
1218
168
168
168
1245
161
161
161
1279
202
202
202
1235
197
197
197
1267
190
190
190
1304
217
217
217
1331

121
151
151
1207
121
158
158
1232
122
151
151
1264
190
190
190
1223
186
186
186
1253
179
179
179
1287
204
204
204
1312

112
112
148
1197
112
149
149
1220
113
143
143
1250
179
179
179
1212
175
175
175
1239
169
169
169
1272
193
193
193
1296

103
103
140
1188
104
104
141
1209
105
105
135
1237
169
169
169
1201
165
165
165
1227
160
160
160
1258
182
182
182
1280

96
96
133
1179
97
97
134
1199
98
98
128
1225
160
160
160
1191
157
157
157
1215
151
151
151
1244
172
172
172
1266

89
89
89
1171
90
90
90
1189
92
92
121
1213
123
152
152
1182
149
149
149
1205
143
143
143
1232
163
163
163
1252

83
83
83
1164
83
83
83
1180
86
86
86
1203
116
116
145
1174
112
112
141
1195
106
106
136
1220
155
155
155
1240

1. In shaded areas, mid-span deck shoring required during construction.


2. q3: q=allowable diaphragm shear (plf): 3=number of welds to support.
3. See pg. 55 for General Notes.

30

Preformed Metal Floor Deck

ASCSteel Deck

3WF Composite Floor Deck


3WF Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Lightweight Concrete (110 pcf)
Total Slab Thickness: 5 1/2 1 Hour Fire Rating Slab Weight: 36.6 psf
No. of
Gage Spans

20/20

20/18

20/16

18/20

18/18

18/16

16/16

1
2
3
q3
1
2
3
q3
1
2
3
q3
1
2
3
q3
1
2
3
q3
1
2
3
q3
1
2
3
q3

Span
80

86

90

96

100

106

110

116

120

126

130

136

140

146

150

334
334
334
1511
337
337
337
1566
338
338
338
1628
402
402
402
1547
406
406
406
1607
408
408
408
1672
473
473
473
1717

305
305
305
1487
307
307
307
1538
309
309
309
1594
367
367
367
1520
371
371
371
1575
373
373
373
1635
432
432
432
1677

280
280
280
1466
282
282
282
1512
284
284
284
1564
337
337
337
1496
340
340
340
1546
342
342
342
1602
396
396
396
1641

258
258
258
1447
260
260
280
1489
262
262
262
1538
311
311
311
1474
314
314
314
1521
316
316
316
1572
365
365
365
1609

239
239
239
1430
241
241
241
1468
242
242
242
1513
288
288
288
1455
290
290
290
1498
292
292
292
1546
338
338
338
1580

222
222
222
1414
224
224
224
1450
225
225
225
1492
267
267
267
1437
270
270
270
1477
272
272
272
1522
314
314
314
1554

207
207
207
1400
209
209
209
1433
210
210
210
1472
249
249
249
1421
252
252
252
1458
253
253
253
1500
293
293
293
1530

194
194
194
1387
195
195
195
1417
196
196
196
1454
233
233
233
1407
235
235
235
1441
237
237
237
1480
274
274
274
1509

150
182
182
1376
157
183
183
1403
151
184
184
1437
219
219
219
1393
221
221
221
1425
222
222
222
1462
257
257
257
1489

139
139
171
1365
140
172
172
1390
140
173
173
1422
206
206
206
1381
208
208
208
1411
209
209
209
1445
242
242
242
1470

129
129
161
1355
130
130
163
1378
130
130
163
1408
194
194
194
1370
196
196
196
1397
197
197
197
1430
228
228
228
1454

120
120
152
1346
121
121
154
1367
121
121
154
1395
183
183
183
1359
185
185
185
1385
186
186
186
1416
216
216
216
1438

112
112
112
1337
113
113
113
1357
113
113
146
1383
174
174
174
1349
175
175
175
1373
176
176
176
1402
204
204
204
1424

105
105
105
1329
106
106
106
1347
106
106
106
1371
132
132
155
1340
133
133
166
1363
134
134
167
1390
194
194
194
1410

98
98
98
1322
99
99
99
1338
99
99
99
1361
124
124
124
1332
125
125
158
1353
126
126
159
1378
150
184
184
1397

1. In shaded areas, mid-span deck shoring required during construction.


2. q3: q=allowable diaphragm shear (plf): 3=number of welds to support.
3. See pg. 55 for General Notes.

December 2013

www.ascsd.com

31

ASCSteel Deck

3WF Composite Floor Deck


3WF Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Lightweight Concrete (110 pcf)
Total Slab Thickness: 6 1/4 2 Hour Fire Rating Slab Weight: 43.6 psf
No. of
Gage Spans

20/20

20/18

20/16

18/20

18/18

18/16

16/16

1
2
3
q3
1
2
3
q3
1
2
3
q3
1
2
3
q3
1
2
3
q3
1
2
3
q3
1
2
3
q3

Span
80

86

90

96

100

106

110

116

120

126

130

136

140

146

150

378
378
378
1748
380
380
380
1803
382
382
382
1865
453
453
453
1784
457
457
457
1844
460
460
460
1909
530
530
530
1954

345
345
345
1724
347
347
347
1774
349
349
349
1831
413
413
413
1757
417
417
417
1812
420
420
420
1872
484
484
484
1913

316
316
316
1703
319
319
319
1749
320
320
320
1801
379
379
379
1733
383
383
383
1783
385
385
385
1839
444
444
444
1878

292
292
292
1684
294
294
294
1726
295
295
295
1775
350
350
350
1711
353
353
353
1758
355
355
355
1809
410
410
410
1846

270
270
270
1667
272
272
272
1705
273
273
273
1750
324
324
324
1692
327
327
327
1735
329
329
329
1783
379
379
379
1817

251
251
251
1651
253
253
253
1687
254
254
254
1729
301
301
301
1674
304
304
304
1714
306
306
306
1759
352
352
352
1791

234
234
234
1637
236
236
236
1670
237
237
237
1709
281
281
281
1658
283
283
283
1645
285
285
285
1737
329
329
329
1767

181
219
219
1624
183
221
221
1654
183
222
222
1691
263
263
263
1644
265
265
265
1678
267
267
267
1717
308
308
308
1745

168
168
206
1613
169
169
207
1640
170
208
208
1674
246
246
246
1630
249
249
249
1662
250
250
250
1699
288
288
288
1726

156
156
193
1602
157
157
195
1627
157
157
196
1659
232
232
232
1618
234
234
234
1648
235
235
235
1682
271
271
271
1707

145
145
182
1592
146
146
184
1615
146
146
184
1645
219
219
219
1606
221
221
221
1634
222
222
222
1667
256
256
256
1691

135
135
135
1583
136
136
136
1604
136
136
136
1632
169
169
207
1596
170
208
208
1622
171
210
210
1653
242
242
242
1675

126
126
126
1574
126
126
126
1594
127
127
127
1619
158
158
158
1586
159
159
197
1610
160
160
199
1639
229
229
229
1661

117
117
117
1566
118
118
118
1584
118
118
118
1608
147
147
147
1577
149
149
187
1600
149
149
188
1627
178
217
217
1647

110
110
110
1559
110
110
110
1575
110
110
110
1598
138
138
138
1569
139
139
178
1590
140
140
179
1615
167
206
206
1634

1. In shaded areas, mid-span deck shoring required during construction.


2. q3: q=allowable diaphragm shear (plf): 3=number of welds to support.
3. See pg. 55 for General Notes.

32

Preformed Metal Floor Deck

ASCSteel Deck

3WF Composite Floor Deck


3WF Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)
Total Slab Thickness: 5 Slab Weight: 42.3 psf
No. of
Gage Spans

20/20

20/18

20/16

18/20

18/18

18/16

16/16

1
2
3
q3
1
2
3
q3
1
2
3
q3
1
2
3
q3
1
2
3
q3
1
2
3
q3
1
2
3
q3

Span
80

86

90

96

100

106

110

116

120

126

130

136

140

146

150

307
307
307
1677
309
309
309
1733
295
295
295
1794
371
371
371
1713
363
363
363
1773
350
350
350
1838
399
399
399
1883

280
280
280
1654
282
282
282
1704
270
270
270
1761
339
339
339
1686
331
331
331
1741
319
319
319
1801
364
364
364
1843

257
257
257
1632
259
259
259
1678
247
247
247
1731
311
311
311
1662
304
304
304
1713
293
293
293
1768
334
334
334
1807

237
237
237
1613
239
239
239
1656
228
228
228
1704
287
287
287
1641
280
280
280
1687
270
270
270
1739
308
308
308
1775

220
220
220
1596
221
221
221
1635
211
211
211
1680
265
265
265
1621
260
260
260
1664
250
250
250
1712
285
285
285
1746

204
204
204
1581
206
206
206
1616
196
196
196
1658
247
247
247
1604
241
241
241
1644
233
233
233
1688
265
265
265
1720

191
191
191
1567
192
192
192
1599
183
183
183
1638
230
230
230
1588
225
225
225
1625
217
217
217
1667
247
247
247
1697

142
178
178
1554
142
179
179
1584
134
171
171
1620
215
215
215
1573
210
210
210
1607
203
203
203
1647
231
231
231
1675

131
131
167
1542
131
131
168
1570
123
161
161
1604
202
202
202
1560
197
197
197
1592
190
190
190
1629
217
217
217
1655

121
121
157
1531
121
121
158
1557
114
114
151
1588
190
190
190
1547
186
186
186
1577
179
179
179
1612
204
204
204
1637

112
112
148
1521
112
112
149
1545
105
105
143
1574
179
179
179
1536
175
175
175
1564
169
169
169
1596
193
193
193
1620

103
103
103
1512
104
104
104
1533
97
97
97
1561
132
169
169
1525
128
165
165
1551
122
160
160
1582
182
182
182
1604

96
96
96
1504
97
97
97
1523
90
90
90
1549
123
123
123
1516
119
119
157
1540
113
113
151
1569
172
172
172
1590

89
89
89
1496
90
90
90
1513
83
83
83
1538
115
115
115
1507
111
111
149
1529
105
105
143
1556
125
163
163
1577

83
83
83
1488
83
83
83
1504
77
77
77
1527
107
107
107
1498
104
104
141
1519
98
98
136
1545
117
155
155
1564

1. In shaded areas, mid-span deck shoring required during construction.


2. q3: q=allowable diaphragm shear (plf): 3=number of welds to support.
3. See pg. 55 for General Notes.

December 2013

www.ascsd.com

33

ASCSteel Deck

3WF Composite Floor Deck


3WF Allowable Superimposed Load (psf) & Diaphragm Shear Capacity (plf) Normal Weight Concrete (145 pcf)
Total Slab Thickness: 5 1/2 Slab Weight: 48.3 psf
No. of
Gage Spans

20/20

20/18

20/16

18/20

18/18

18/16

16/16

1
2
3
q3
1
2
3
q3
1
2
3
q3
1
2
3
q3
1
2
3
q3
1
2
3
q3
1
2
3
q3

Span
80

86

90

96

100

106

110

116

120

126

130

136

140

146

150

334
334
334
1917
337
337
337
1972
338
338
338
2034
402
402
402
1953
406
406
406
2012
405
405
405
2077
473
473
473
2122

305
305
305
1893
307
307
307
1943
309
309
309
2000
367
367
367
1925
371
371
371
1980
373
373
373
2040
432
432
432
2082

280
280
280
1871
282
282
282
1917
284
284
284
1970
337
337
337
1901
340
340
340
1952
342
342
342
2007
396
396
396
2046

258
258
258
1852
260
260
260
1895
262
262
262
1943
311
311
311
1880
314
314
314
1926
316
316
316
1978
365
365
365
2014

239
239
239
1835
241
241
241
1874
242
242
242
1919
288
288
288
1860
290
290
290
1903
292
292
292
1951
338
338
338
1985

222
222
222
1820
224
224
224
1855
225
225
225
1897
267
267
267
1843
270
270
270
1883
272
272
272
1928
314
314
314
1959

166
207
207
1806
167
209
209
1838
168
210
210
1877
249
249
249
1827
252
252
252
1864
253
253
253
1906
293
293
293
1936

153
153
194
1793
154
154
195
1823
154
196
196
1859
233
233
233
1812
235
235
235
1847
237
237
237
1886
274
274
274
1914

141
141
182
1781
142
142
183
1809
142
142
184
1843
219
219
219
1799
221
221
221
1831
222
222
222
1868
257
257
257
1894

130
130
171
1770
131
131
172
1796
131
131
173
1827
206
206
206
1786
208
208
208
1816
209
209
209
1851
242
242
242
1876

120
120
120
1760
121
121
121
1784
121
121
121
1813
152
152
194
1775
154
196
196
1803
154
197
197
1835
228
228
228
1859

111
111
111
1751
112
112
112
1772
112
112
112
1800
141
141
141
1765
143
143
185
1790
144
144
186
1821
216
216
216
1844

103
103
103
1743
104
104
104
1762
104
104
104
1788
132
132
132
1755
133
133
175
1779
134
134
176
1808
204
204
204
1829

95
95
95
1735
96
96
96
1752
96
96
96
1777
123
123
123
1746
124
124
124
1768
125
125
167
1795
150
194
194
1816

89
89
89
1727
89
89
89
1743
89
89
89
1766
115
115
115
1737
116
116
116
1758
116
116
116
1784
141
141
184
1803

1. In shaded areas, mid-span deck shoring required during construction.


2. q3: q=allowable diaphragm shear (plf): 3=number of welds to support.
3. See pg. 55 for General Notes.

34

Preformed Metal Floor Deck

ASCSteel Deck

CF 7/8 Concrete Form


CF 7/8-Section Properties

223

Weight

S+

S--

Gage

(psf)

(In4)

(In3)

(In3)

26
24
22
20

1.04
1.33
1.62
1.94

0.027
0.035
0.043
0.051

0.060
0.078
0.095
0.113

0.060
0.078
0.095
0.113

32 Coverage

78

Allowable Total (DL + LL) Uniform Load (psf)


Span
Condition

CF-7/8
Gage

26

SINGLE
SPAN

24
22
20
26

DOUBLE
SPAN

24
22
20
26

TRIPLE
SPAN

24
22
20

Span (ft)
20

26

30

36

40

46

50

56

60

66

70

Stress

360

230

160

118

90

71

58

48

40

34

29

Defl

295

151

87

55

37

26

19

14

11

Stress

468

300

208

153

117

92

75

62

52

44

38

Defl

382

196

113

71

48

34

24

18

14

11

Stress

570

365

253

186

143

113

91

75

63

54

47

Defl

470

241

139

88

59

41

30

23

17

14

11

Stress

678

434

301

221

170

134

108

90

75

64

55

Defl

557

285

165

104

70

49

36

27

21

16

13

Stress

360

230

160

118

90

71

58

48

40

34

29

Defl

360

230

160

118

88

62

45

34

26

20

16

Stress

468

300

208

153

117

92

75

62

52

44

38

Defl

468

300

208

153

115

80

58

44

34

26

21

Stress

570

365

253

186

143

113

91

75

63

54

47

Defl

570

365

253

186

141

99

72

54

41

32

26

Stress

678

434

301

221

170

134

108

90

75

64

55

Defl

678

434

301

221

167

117

85

64

49

39

31

Stress

450

288

200

147

113

89

72

60

50

43

37

Defl

450

285

164

103

69

48

35

26

20

16

12

Stress

585

374

260

191

146

116

94

77

65

55

48

Defl

585

369

213

134

90

63

46

34

26

21

16

Stress

713

456

317

233

189

141

114

94

79

67

58

Defl

713

453

262

165

110

77

56

42

32

25

20

Stress

848

542

377

277

212

167

136

112

94

80

69

Defl

848

538

311

196

131

92

67

50

38

30

24

1. Stress based on allowable flexural stress of 36 ksi.


2. Deflection based on maximum Deflection of L/180.
3. Adequate bearing must be provided.

December 2013

www.ascsd.com

35

ASCSteel Deck

CF 1 3/8 Concrete Form


CF 1 3/8 - Section Properties

4-9/16

1-3/8

32
FD10 CF 1-3/8

Weight

S+

S--

Gage

(psf)

(In4)

(In3)

(In3)

26
24
22
20
18

1.04
1.33
1.62
1.92
2.56

0.072
0.065
0.122
0.146
0.195

0.094
0.131
0.169
0.205
0.263

0.094
0.131
0.169
0.205
0.263

CF 1 3/8 Allowable Total (DL + LL) Uniform Load (psf)


Span
Condition

CF 1 3/8
Gage

26
24
SINGLE
SPAN

22
20
18
26
24

DOUBLE
SPAN

22
20
18
26
24

TRIPLE
SPAN

22
20
18

Stress
Defl
Stress
Defl
Stress
Defl
Stress
Defl
Stress
Defl
Stress
Defl
Stress
Defl
Stress
Defl
Stress
Defl
Stress
Defl
Stress
Defl
Stress
Defl
Stress
Defl
Stress
Defl
Stress
Defl

Span (ft)
20

26

30

36

40

46

50

56

60

66

70

251
233
349
317
451
395
547
473
444
444
251
251
349
349
451
451
547
547
444
444
313
313
437
437
563
563
683
683
555
555

184
147
257
200
331
249
402
298
326
326
184
184
257
257
331
331
402
402
326
326
230
230
321
321
414
414
502
502
407
407

141
98
197
134
254
167
308
199
249
249
141
141
197
197
254
254
308
308
249
249
176
176
246
246
319
319
384
376
312
312

111
69
155
94
200
117
243
140
197
187
111
111
155
155
200
200
243
243
197
197
139
130
194
177
250
220
304
264
246
246

90
50
126
69
162
85
197
102
159
136
90
90
126
126
162
162
197
197
159
159
113
95
157
129
203
160
246
192
199
199

75
38
104
51
134
64
163
77
132
102
75
75
104
104
134
134
163
163
132
132
93
71
130
97
168
120
203
144
165
165

63
29
87
40
113
49
137
59
111
79
63
62
87
87
113
113
137
137
111
111
78
54
109
74
141
93
171
111
138
138

53
23
74
31
96
39
116
46
94
62
53
53
74
74
96
93
116
111
94
94
67
43
93
58
120
73
146
87
118
117

46
18
64
25
83
31
100
37
81
50
46
44
64
60
83
74
100
89
81
81
58
34
80
47
103
58
126
70
101
93

40
15
56
20
72
25
87
30
71
40
40
35
56
48
72
60
87
72
71
71
50
28
70
38
90
47
109
57
88
76

35
12
49
17
63
21
77
25
62
33
35
29
49
40
63
50
77
59
62
62
44
23
61
31
79
39
96
47
78
62

1. Stress based on allowable flexural stress of 36 ksi (for 18 ga. stress based on allowable flexural stress of 22.8 ksi).
2. Deflection based on maximum Deflection of L/180.
3. Adequate bearing must be provided.

36

Preformed Metal Floor Deck

ASCSteel Deck

Deep Deck (Form)


4 1/2 Deep Deck - Section Properties

4-1/2

12
FD11

Weight

S+

S--

Gage

(psf)

(In4)

(In3)

(In3)

20
18
16
14

2.86
3.74
4.69
5.86

2.44
3.42
4.36
5.49

0.924
1.266
1.608
2.056

0.957
1.313
1.635
2.056

1. Section properties are based on minimum 33 ksi steel (Fy)

4-1/2 Deep Deck (Form)

4 1/2 Deep Deck Allowable Total (DL + LL) Uniform Load (psf)
Span

CF-7/8

Condition

Span (ft)

Gage

20
18

SINGLE
SPAN

16
14

100

120

140

160

180

200

220

240

260

280

300

Stress

123

86

63

48

38

31

25

21

18

16

14

Defl

123

86

58

39

27

20

15

12

Stress

169

117

86

66

52

42

35

29

25

22

19

Defl

169

117

82

55

38

28

21

16

13

10

Stress

214

149

109

84

66

54

44

37

32

27

24

Defl

214

149

104

70

49

36

27

21

16

13

11

Stress

274

190

140

107

85

69

57

48

41

35

30

Defl

274

190

131

88

62

45

34

26

20

16

13

6 Deep Deck - Section Properties

12

Weight

S+

S--

Gage

(psf)

(In4)

(In3)

(In3)

20
18
16
14

3.22
4.22
5.29
6.61

4.79
6.68
8.56
10.78

1.386
1.892
2.406
3.085

1.314
1.966
2.451
3.087

1. Section properties are based on minimum 33 ksi steel (Fy)

FD12 6 Deep Deck (Form)

6 Deep Deck Allowable Total (DL + LL) Uniform Load (psf)


Span
Condition

CF-7/8
Gage

20

SINGLE
SPAN

18
16
14

Span (ft)
100

120

140

160

180

200

220

240

260

280

300

Stress

185

128

94

72

57

46

38

32

27

24

21

Defl

185

128

94

72

54

39

29

23

18

14

12

Stress

252

175

129

99

78

63

52

44

37

32

28

Defl

252

175

129

99

75

55

41

32

25

20

16

Stress

321

223

164

125

99

80

66

56

47

41

36

Defl

321

223

164

125

96

70

53

41

32

26

21

Stress

411

268

210

161

127

103

85

71

61

52

46

Defl

411

286

210

161

121

88

66

51

40

32

26

1. Loads based on bending stress limit of Fb=20 ksi or Deflection limit of L/240.
2. Bearing must be checked using actual loads and bearing lengths.

December 2013

www.ascsd.com

37

ASCSteel Deck

Deep Deck (Form)


9

7 1/2 Deep Deck - Section Properties

7-1/2

Weight

S+

S--

Gage

(psf)

(In4)

(In3)

(In3)

20
18
16
14

3.59
4.7
5.9
7.38

8.11
11.28
14.47
18.26

1.899
2.593
3.3
4.238

1.67
2.528
3.367
4.245

1. Section properties are based on minimum 33 ksi steel (Fy)


12

7 1/2 Deep Deck Allowable Total (DL + LL) Uniform Load (psf)
FD13

Span
Condition

CF-7/8
Gage

20

SINGLE
SPAN

7-1/2 Deep Deck

18
16
14

Span (ft)
100

120

140

160

180

200

220

240

260

280

300

Stress

253

176

129

99

78

63

52

44

37

32

28

Defl

253

176

129

99

78

63

50

38

30

24

20

Stress

346

240

176

135

107

86

71

60

51

44

38

Defl

346

240

176

135

107

86

69

53

42

34

27

Stress

440

306

224

172

136

110

91

76

65

56

49

Defl

440

306

224

172

136

110

89

69

54

43

35

Stress

565

392

288

221

174

141

117

98

84

72

63

Defl

565

392

288

221

174

141

112

87

68

55

44

1. Loads based on bending stress limit of Fb=20 ksi or Deflection limit of L/240.
2. Bearing must be checked using actual loads and bearing lengths.

38

Preformed Metal Floor Deck

ASCSteel Deck

General Notes
The following notes apply to the allowable total load tables
and/or to the allowable superimposed load & diaphragm
shear tables.
1. Arc spot or arc seam (puddle) welds shall have an
effective fusion area, to supporting members,

equivalent to at least 3/8 by 1 long or 1/2 in diameter.
2. Spacing of marginal welds to members parallel to the
flutes:
(a) Arc spot (puddle) welds to members, such as
chords, and to collector elements, such as struts
or ties, shall have a spacing in feet equal to
32,000 (t) /v, where:
t = Uncoated steel thickness of fluted deck in
inches. (see ICC report for t)
v = Actual diaphragm shear at marginal supports
or actual shear transferred to collector (at
struts or ties) in pounds per foot.
(b) Fillet welds to members, such as diaphragm
chords, shall have a spacing in feet equal to 480
Iw/v, where:
lw = Length of weld in inches (not less than 1 1/2
v = Actual diaphragm shear to be transferred to
chords in pounds per foot.
(c) Fillet welds attaching the diaphragm to
struts, ties or other collector elements shall
have a spacing, in feet, equal to 300 Iw/v
where:
v = Actual diaphragm shear to be transferred
to the collector element, in pounds per foot.
(d) In no case shall any weld spacing exceed 30.
3. Attachments at interior lines of shear transfer,

perpendicular to deck corrugations:
(a) The shear transfer from a diaphragm to interior
ties or strut lines, perpendicular to deck
corrugations, shall not exceed the shear values
indicated in the tables. Two lines of puddle
welds may be used to develop the actual shear
transfer to these collector elements.

December 2013

4. The minimum 28-day compressive strength for structural


concrete shall be 3000 psi and the density as indicated
in the tables or as required for fire rating. The minimum
depth of concrete shall be 2 over the top flange and it
is to be reinforced with a minimum 6 x 6 W1.4 x W1.4
welded wire fabric. The reinforcement shall be placed
near the center of the fill, over the top flange. If fill
exceeds 3 1/4 thick the reinforcement area must
equal 0.00075 times the depth of fill over top of deck,
each way.
5. All decks with structural concrete fill may be considered
rigid diaphragms, f<1.0, unless otherwise noted.
6. Shoring calculations are based on the deck profile
supporting the dead load of concrete, plus either:
(a) a 20 psf uniform construction load, or
(b) a 150 lb. concentrated live load for flexure.

The dead load Deflection is limited to L/180, but not to

exceed 3/4.
7. Total Slab Thickness: is the nominal total slab depth,

measured from the bottom flange of the rib to the top of
the concrete. This applies to all allowable

superimposed load and diaphragm shear tables.
8. For all cellular profiles, the first number of the Gage

designation (20/20) refers to beam section (corrugated
profile). The second number (20/20) refers to the pan
section (flat plate).
9. Seam attachment for composite floor deck to be
minimum button punch @ 36 O.C.
10. Typical floor deck manufacturing tolerances:
Panel length: +/- 1/2
Thickness: Not less than 95% of the design


base metal thickness
Panel cover width: -3/8, + 3/4
Panel camber/sweep: 1/4 in 10 length
Panel end out of square: 1/8 per foot of panel width

www.ascsd.com

39

ASCSteel Deck

Fire Resistance Ratings


Fire Resistance Rating-Floor Deck
Restrained
Assembly
Hourly Rating

UL
Design
No.

1,1 1/2, 2 & 3


3&
1, 1 1/2, 2
1,1 1/2 & 2
1, 1 1/2, 2, 3 & 4
2
1, 1 1/2, 2 & 3
3
2&3
1, 1 1/2, 2 & 3
2, 3 & 4
3&4
2
3
3
1, 1 1/2, 2 & 3
1, 1 1/2, 2, 3 & 4
2
1, 1 1/2, 2 & 3
2&3
2
1, 1 1/2, 2, 3 & 4
2
3
1, 1 1/2, 2 & 3
1, 1 1/2, 2 & 3
1
1
1 1/2
1 1/2
2
2
3
3
2
3/4 or 1
3/4 or 1
1
1 1/2
1 1/2
2
2
3
3
1
1
1 1/2
2
2
3
3

D703
D708
D712
D722
D739
D740
D743
D753
D755
D759
D760
D754
D764
D768
D776
D780
D782
D826
D832
D833
D840
D858
D861
D863
D859
D871

40

D902

D907
D914

D916
D925
D927

D918

Concrete Thickness
(Above Deck)
Type

2
2
2
2
2

1/2 LWT & NWT


1/2 LWT & NWT
1/2 LWT & NWT
1/2 LWT & NWT
1/2 LWT & NWT
2 1/2 NWT
2 LWT & NWT
2 3/4 LWT & NWT
2 1/2 LWT & NWT
2 1/2 LWT & NWT
2 1/2 LWT & NWT
3 1/4 LWT
2 1/2 LWT
2 1/2 LWT & NWT
2 3/4 LWT & NWT
2 1/2 LWT & NWT
3 1/4 LWT
3 1/4 LWT
2 1/2 LWT & NWT
2 1/2 LWT & NWT
3 1/4 LWT
2 1/2 LWT & NWT
2 1/2 LWT & NWT
2 3/4 LWT & NWT
2 LWT & NWT
2 1/2 LWT & NWT
2 1/2 LWT
3 1/2 NWT
3 LWT
4 NWT
3 1/4 LWT
4 1/2 NWT
4 3/16 LWT
5 1/4 NWT
3 1/4 LWT
2 1/2 LWT
2 1/2 LWT
3 1/2 NWT
3 LWT
4 NWT
3 1/4 LWT
4 1/2 NWT
4 3/16 LWT
5 1/4 NWT
2 1/2 LWT
3 1/2 NWT
4 NWT
3 1/4 LWT
4 1/2 NWT
4 3/16 LWT
5 1/4 NWT

Profile

Fireproofing
Type

2W, 3W
B, BF, N, NF, 2W & 3W
N, NF, 2W
N, NF, 2W, 3W
B, BF, N, NF, 2W, 2WF, 3W, 3WF
B
2W, 2WF, 3W, 3WF
CF-7/8 & CF-1 3/8
B, BF, 2W, 3W
B, 2W, 2WF, 3W, 3WF
B, 2W & 3W
B, N, 2W & 3W
B, BF N, NF, 2W, 2WF, 3W, 3WF
B, BF, N, NF, 2W & 3W
CF-7/8 & CF-1 3/8
CF-7/8 & CF-1 3/8
B, N, 2W & 3W
B, BF, N, NF, 2W & 3W
B, BF, 2W, 3W
2W
B, BF, N, NF, 2W & 3W
2W, 3W
2W
CF-7/8 & CF-1 3/8
2W, 3W
2W & 3W

Cementitious
Cementitious
Cementitious
Cementitious
Cementitious
Cementitious
Cementitious
Cementitious
Cementitious
Cementitious
Cementitious
Cementitious
Cementitious
Cementitious
Cementitious
Cementitious
Cementitious
None
Fiberous
Fiberous
None
Fiberous
Fiberous
Fiberous
Fiberous
Fiberous

B, BF, N, NF, 2W, 2WF, 3W, 3WF

None

B, BF, N, NF, 2W, 2WF, 3W, 3WF


B, BF, N, NF, 2WF, 3W, 3WF

None
None

B, BF, N, NF, 2W, 2WF, 3W, 3WF

B, BF, N, NF, 2W, 2WF, 3W, 3WF

None

None

Preformed Metal Floor Deck

ASCSteel Deck

Fire Resistance Ratings continued


Fire Resistance Rating-Floor Deck
Restrained
Assembly
Hourly Rating

1
1
1 1/2
1 1/2
2
2
3
3
2
3/4 or 1
1
1 1/2
1 1/2
2
2

December 2013

UL
Design
No.

D919
D931

D920

D929

Concrete Thickness
(Above Deck)
Type

2 1/2 LWT
3 1/2 NWT
3 LWT
4 NWT
3 1/4 LWT
4 1/2 NWT
4 3/16 LWT
5 1/4 NWT
3 1/4 LWT
2 1/2 LWT
3 1/2 NWT
3 LWT
4 NWT
3 1/4 LWT
4 1/2 NWT

Profile

Fireproofing
Type

B, BF, N, NF, 2W, 2WF, 3W, 3WF

None

2W, 2WF, 3W, 3WF

None

B, BF, N, NF, 2W, 2WF, 3W, 3WF


None

www.ascsd.com

41

ASCSteel Deck

Concrete Weights and Volumes


Depth of Slab Over the Top of the Rib
Description

Cubic Yards
Per 100 Sq.
Ft. of Area

Lightweight
Concrete
(110 Pcf)
Wt. Per Sq.
Ft. of Area

Normal
Weight
Concrete
(145 Pcf)
Wt. Per Sq.
Ft. of Area

ASC Profile

2 1/2

3 1/4

3 1/2

4 3/16

4 1/4

4 1/2

B-36, BF-36
ShearVent
BR-36
2W, 2WF
3W, 3WF
N-32 NF-32
CP-32
CF-7/8
CF-1 3/8
B-36, BF-36
BR-36
2W, 2WF
3W, 3WF
N-32 NF-32
CF-7/8
CF-1 3/8
B-36, BF-36
BR-36
2W, 2WF
3W, 3WF
N-32 NF-32
CF-7/8
CF-1 3/8

0.927
0.927
1.079
1.080
1.236
1.156
0.984
0.907
0.984
27.531
32.046
32.076
36.079
34.332
26.938
29.225
36.292
42.243
42.282
48.389
45.256
35.509
38.524

1.082
1.082
1.233
1.235
1.389
1.313
1.138
1.061
1.138
32.135
36.620
36.680
41.253
39.007
31.512
33.800
42.360
48.222
48.350
54.379
51.418
41.538
66.553

1.159
1.159
1.130
1.312
1.466
1.392
1.215
1.138
1.215
34.422
39.907
39.966
43.540
41.345
33.799
36.084
45.375
51.287
51.365
57.394
54.500
44.553
47.567

1.236
1.236
1.388
1.389
1.543
1.471
1.292
1.215
1.282
36.709
41.224
41.253
45.827
43.682
36.086
38.372
48.389
54.340
54.379
60.408
57.581
47.567
50.582

1.390
1.390
1.542
1.543
1.698
1.628
1.447
1.370
1.447
41.283
45.797
45.827
50.431
48.357
40.869
42.976
54.419
60.369
60.408
66.477
63.743
53.636
56.650

1.448
1.448
1.600
1.601
1.755
1.687
1.505
1.427
1.505
43.006
47.520
47.550
52.124
50.110
42.382
44.700
56.689
62.640
62.679
68.708
66.054
55.867
58.921

1.467
1.467
1.619
1.620
1.775
1.707
1.524
1.447
1.524
43.570
48.084
48.114
52.716
50.695
42.976
45.263
57.433
63.384
63.423
69.491
66.825
56.650
59.665

1.545
1.545
1.696
1.696
1.852
1.786
1.601
1.524
1.601
45.887
50.371
50.431
55.004
53.032
45.263
47.550
60.487
66.398
66.477
72.506
69.906
59.665
62.679

1. Deck Deflection not considered.


2. Placement of concrete is to comply with ACI Manual of Concrete Practice.
Code Approvals
ASCs steel deck profiles have been evaluated or approved for use by:
1. ICC Evaluation Service Report No. 1414 and 2408.
2. City of Los Angeles Research Report Nos. 23783 23784 and 25762.
3. Factory Mutual

42

Preformed Metal Floor Deck

ASCSteel Deck

Comments on Extraordinary Conditions


A.




Positive Bending Reinforcement


The deck profile in a composite slab design is the positive
bending reinforcement for the slab and must be expected
to last the life of the structure. To ensure the integrity of the
structure, ASC Steel Deck recommends specifying ASTM A653,
G-60 as the minimally acceptable finish.

B. Parking Structures
The following conditions are to be considered when
using steel deck in a parking structure.
1. All slabs are to be designed as continuous spans
with negative reinforcement placed over each
support. Alternatively, the steel deck may be used
as a concrete form with reinforcement as required.
2. Additional reinforcing is to be included to
minimize cracking caused by temperature
differential and to provide load distribution.
3. The minimally acceptable galvanized coating is
G-90, as per ASTM A653.
4. In corrosive environments, the top surface of the
slab is to be sealed and the bottom surface of the
steel deck is to receive a field applied finish paint.
C.



E. Cantilevers
Steel deck used in a cantilevered condition acts solely
as a permanent form. The length of the cantilever may
be determined using the section properties of the steel
deck profile. Negative reinforcement, designed by the
structural engineer, is to be added over the support to
prevent cracking of the slab.
F.






1% Venting
Steel decking used in composite construction should
be vented when the slab may be exposed to
water, post construction. The vented steel deck
will allow the dissipation of residual water vapor. The
venting may be produced using punched hole or vent
tabs. Contact ASC for more specific information per the
specific profile.

Vibratory Load
Vibratory Loads, e.g., mechanical equipment and forklifts are
detrimental to the mechanical bond between the
deck and concrete. Additional reinforcing steel, designed
by the structural engineer, may be required.

D. Point Load
To determine the required deck type and concrete for
a point load condition, an equivalent uniform load for a
simple span is calculated.
Example:
1. 100 Span
2. 400 # Point Load at Mid-Span
3. 50 PSF Uniform Floor Load
Determine total equivalent uniform superimposed load.
A. Maximum Moment from Point Load:
M=PL/4=400(10)/4=1000 ft. Ibs.
B. Equivalent Uniform Load:
W=LM(8) =1000(8) 10
= 80 PSF
C. Total Equivalent Superimposed Load:
50 + 80 = 130 PSF
* Note: Select deck type, concrete type and
thickness with a 130 PSF allowable super imposed load capacity and span length of
100. Provide distribution steel as required.
2

December 2013

www.ascsd.com

43

ASCSteel Deck

SDI Edge Form


3

10

11

12

20
20
20
20
20
18
18
18
18
18
16
16
16
16
14
14
14
14
12
12
12
12
12
12
12
12
12
10
10
10
10
10
10

20
20
20
18
18
18
18
16
16
16
16
14
14
14
14
14
12
12
12
12
12
12
12
12
10
10
10
10
10
10
10

20
18
18
18
18
16
16
16
16
14
14
14
14
14
12
12
12
12
12
12
12
12
10
10
10
10
10
10
10

18
18
18
16
16
16
16
14
14
14
14
14
12
12
12
12
12
12
12
12
10
10
10
10
10
10
10

18
16
16
16
16
14
14
14
14
12
12
12
12
12
12
12
12
10
10
10
10
10
10
10
10

16
16
16
14
14
14
14
12
12
12
12
12
12
12
12
10
10
10
10
10
10
10

14
14
14
14
14
12
12
12
12
12
12
12
12
10
10
10
10
10
10
10

12
12
12
12
12
12
12
12
12
12
12
10
10
10
10
10
10
10

12
12
12
12
12
12
12
12
10
10
10
10
10
10
10
10

12
12
12
10
10
10
10
10
10
10
10
10
10

10
10
10
10
10
10
10
10
10

10
10
10
10

in

20
20
20
20
20
20
20
20
18
18
18
18
16
16
16
16
14
14
14
14
14
12
12
12
12
12
12
12
12
12
10
10
10

4.00
4.25
4.50
4.75
5.00
5.25
5.50
5.75
6.00
6.25
6.50
6.75
7.00
7.25
7.50
7.75
8.00
8.25
8.50
8.75
9.00
9.25
9.50
9.75
10.00
10.25
10.50
10.75
11.00
11.25
11.50
11.75
12.00

Deck Institute, the author of the following table.

1/

SDI is the Steel


Slab
Depth
0

1 Fillet Welds @ 12 O.C.


Pour
Stop

Slab
Depth

Edge Form Detail

The above Selection Table is based on the following criteria:


1. Normal weight concrete (150 pcf).
2. Horizontal and vertical Deflection is limited to 1/4 maximum for concrete dead load

2 min.
Overhang
FD14 Edge Form detail

3. Design stress is limited to 20 ksi for concrete dead load temporarily increased by one-third for the construction live load of 20 psf.
4. Pour Stop Selection Table does not consider the effect of the performance, Deflection, or rotation of the pour stop support which may
include both the supporting composite deck and/or the frame.
5. Vertical leg return lip is recommended for type 16 and lighter.
6. This selection is not meant to replace the judgement of experienced Structural Engineers and shall be considered as a reference only.
7. SDI reserves the right to change any information in this section without notice.

44

Preformed Metal Floor Deck

ASCSteel Deck

Floor Deck Accessories and Standard Details


Filler Plate

Profile
Closures
Profile Closures

Filler Plate

Varies
Not to exceed 8
(clear span)

Small Void

Large Void
FD16 Filler Plate

FD15 Steel Closures

Curved
WeldWasher
Washers
Curved Weld

RaisedEdge
Edge Weld
Washer
Raised
Weld
Washer

14 gauge X 3/8 dia. hole for welded attachment of CF 1-3/8

14 gauge X 3/8 dia. hole for welded attachment of CF 7/8.

14 Gage x 3/8 dia.


hole for welded
attachment of
CF 1 3/8

14 Gage x 3/8 dia.


hole for welded
attachment of CF 7/8
3/4

Z Closure

Z Closure

Edge Form

Cell Closure

Cell Closure

Edge Form
1

1/2

Recommended for 16 ga. and lighter.

Varies
(Based on
deck height)

Varies
(Based on
Slab Height)

Varies
(Based on deck
height)
1-1/2

Varies
(Based on Gauge)

FD17 Z Closure

FD18 Edge Form

Edge From at the Parallel Condition

Filler Plate

FD19at
Cellthe
Closure
Edge From
Perpendicular
Condition

FD21 Filler Plate


FD22 Edge Form at the Perpendicular Condition

Stud Locations

FD20 Edge Form at the Parallel Condition

Cell Closure

FD24 Cell Closure

FD23 Stud Locations

December 2013

www.ascsd.com

45

ASCSteel Deck

Materials and Finishes



The B, N, 2W, 2WF, 3W and 3WF profiles are manufactured
from steel conforming to ASTM A653 (Fy=38ksi). CF profiles
are manufactured from steel conforming to ASTM A653 (Grade
E), except CF 1 3/8 (18 ga) which is manufactured from steel
conforming to ASTM A653 (Fy=38ksi).

The standard galvanized coatings are G-60 (.60 oz./ft2)
or G-90 (.90 oz./ft.2) in accordance with ASTM A653. The
B, 2W, 2WF, 3W, and 3WF are available in G-60 and G-90. The
CF profiles are available in G-90. Please inquire for the availability
of alternate coatings.
Please Note: spot weld discoloration will not be a reason for
rejection of cellular deck.
The cellular decking listed in this catalog is manufactured
from two sections of galvanized steel that are joined with resistance
welds. The deck coating and finish will be removed, from the area
of the resistance weld, during this process. This condition should
be considered when determining the fitness of this product for a
specific application. This condition will also not be an acceptable
cause for rejection of the material. Please contact your ASCSteel
Deck representative for additional information on this subject.

ASCSteel Deck reserves the right to make revisions in the


design and/or specifications of our products without prior notice.
Dimensions and specifications of products are subject to normal
manufacturing tolerances. Consult factory concerning availability
of product.

The information in this brochure is, to the best of our
knowledge, accurate. However, no information, representation
nor formula contained herein is designed to replace the judgement
of an experienced structural engineer or other professional
designer. ASCSteel Deck assumes no liability whatsoever for the
accuracy or completeness of the information contained in this
brochure, nor for the suitability of the material for its intended
purpose.

ASCSteel Deck
1-800-726-2727

Metric Conversion Chart


Metric Conversions


Spans, Length and Thickness




Vertical Load and Superimposed Load


Area


Diaphragm Shear

Section Properties



Weight


Volume
46

Multiply

By

Inches
Feet
Inches
Feet
psf
psi
Square feet
Square
plf
in3/ft
in4/ft
in3/ft
in4/ft
Pounds
psf
pcf

25.4
Millimetres
304.8 Millimetres
0.0254 Metres
0.3048 Metres
0.0479
kPa
6.8948 kPa
0.0929
Square Metre
9.2903
Square Metre
0.0146
KN/m
53,763 mm3/m
1,365,588 mm4/m
53.763 cm3/m
136.559 cm4/m
0.00445 kN
4.8824 kg/m2
16.018
kg/m3

To Obtain

Preformed Metal Floor Deck

Manufacturing Facilities
ASCSteel Deck Sacramento, CA
2110 Enterprise Boulevard
West Sacramento, CA 95691
916-372-6851
800-726-2727
ASCSteel Deck Fontana, CA
8432 Almeria Avenue
Fontana, CA 92335
Visit us at:
www.ascsd.com

2008-2013 ASC Profiles LLC

December 2013 50 DL021

You might also like