When the controller is used with any three-wire power regulation constant current source, the yellow or green

PWM signal wire will output PWM square wave to constant current source by corresponding duty ratio and based on the pre-configured parameters by user, allowing the constant current power source to adjust the load power. If the maximum power of lamp reaches 100W, and the preset power regulation is 50W, the yellow wire will output the square wave to the constant current source by the duty ratio up to 50%, with the load power reduced to 50W; TT12/2410LI-B is a type of controller for constant current output, which enables 3/6 string LEDs (12V/24V system) to output constant current (average current) in no need of any constant current source. IV. List of Controller Parameters
Model Rated voltage Maximum charging current Maximum discharging current Static power Ambient temperature Protection grade Time switch Peak charging voltage Under-voltage protection voltage Voltage out of under-voltage protection Light-opening illumination Light-closing illumination Dimensions Weight Output mode Range of application -{}DT12/2405LI-A DT12/2410LI-A TT12/2420LI-A TT12/2410LI- B

Nanjing Putian Datang Information Electronics Co., Ltd.

12V/24V adaptive 5A 5A 4.5 MA 40'C75'C IP67 ex-factory settings: 800m per segment(with two segments available and power 14. 5V (25 ) , varying with temperature adjustable) ex-factory setting 10. 8V(adjustable) ex-factory setting 12. 5V (adjustable) ex-factory setting 12. 5V(adjustable) 10A 10A 20A 20A 6.5 VIA IOA 10A

Solar-Powered Controller Manual

ex-factory setting 10lux (adjustable) ex-factory setting 12. 5V (adjustable) ex-factorylight-opening setting 12. 5V(adjustable) illumination+10luxLight-opening illumination 7. 7x5. lx2. 2 (cm) 128g Single output 128g128g 2x2. 2 (cm) 7. 7x5. lx2. 2 (cm) 250g 128g128g Dual output 7. 7xl0.

solar-powered system with the maximum charging/discharging current within the

scope of 5A~20A Constant current range of TT12/2410LI-B type controller: 0.2A-10A, with constant current accuracy between 0.2A, and minimum load adjustable to 3W.controllers V. Descriptions of C &up D-type

DT12/2405LI-C, DT12/2410LI-C and TT12/2420LI-C controllers are respectively improved products based on DT12/2405LI-A, DT12/2410LI-A and TT12/2420LI-A types, which can automatically adjust the output duty ratio of PWM power regulation line according to the battery voltage after load discharge, reduce the output power in proportion, through a constant current source with two-wire power regulation function and on the basis of the preset power, and protract the discharge time of battery. Table of Proportional Control battery voltage after discharge (V) V12.5V 10.8V~V~ 12.5V ratio of output power to preset power(p) 100% 30% P 99% (the controller automatically adjusts) Nanjing Putian Datang Information Electronics Co., Ltd. Address No.8, Fenghui Av., Yuhua Economic Development Zone, Nanjing Tel :025-58966966 Fax :025-59966965 5,896,696,858,966,965 Website: www.ptdt.cn

Applicable models: DT12/2405LI-A, TT12/2420LI-A DT12/2410LI-A, TT12/2410LI-B

Thank you for using Putian Datangs controller product s with high-end technology and attentive services! The wiring diagrams of such products are provided below.
The controller series are new-generation products developed by our company in the field of solar control products, featuring in high protection grade, multipurpose, simple and flexible configuration, etc. The minimum charge current of this product is 10mA, enabling to charge in cloudy or rainy day, or any other case that the light is insufficient. The controller series are omni-sealed and waterproof. They adopt infrared remote control technology, without any exposed button or equipment, so they are really anti-corrosion, waterproof and dustproof, and they can be widely applied to solar-powered streetlights, garden lamps, lawn lamps and various small-scale applications of solar power. Such solar controllers are your first choice!

The applicable models referred in this manual include: DT12/2405LI-A DT12/2410LI-A l TT1 2/2420LI-A

TT12/2410LI-B

1) As depicted above, the lead wire from left to right covers: common anode (the anodes of load, battery and solar panel are all connected to this line), cathodes of solar panel, battery and load, pulse width modulation line, and temperature sensor line. 2) Order of connection: connect the anodes of battery, solar panel and load to the anode of the controller first; and then, Features 1. Use microprocessor with strong anti-interference capability and dedicated control program to achieve the three-segment intelligent control. The controllers are stable and reliable. 2. Have infrared communication function, which enable users to configure various operational parameters for the controllers via operational software or hand-held programmer and to view running state and load control, such as: to set the light-opening/closing illumination; power-saving mode settings: to allow the three-segment independent load output power settings, so as to achieve energy saving purpose; to allow viewing the current working status and faults of controller 3: have perfect protection functions reverse voltage protection: to enable the reverse voltage protection for solar panel or battery, and in case of any reverse connection, the controller will stop working and trigger reliable protection; lightning protection: to have built-in lightening arrestor, which effectively protects controller, solar panels, battery and load from lightning damage; waterproof/dust protection: protection grade IP67 and fully waterproof and maintaining normal work despite harsh environment; charge and discharge protection: adopt charge and discharge protection optionally according to the negative temperature characteristics of battery. Charge protection refers to ensure the battery is not overcharged but full through selecting different charging curve based on the ambient temperature selected Under-voltage protection refers that, when the battery voltage falls to the voltage value for under-voltage protection(e.g.: 10.8V), turn load off, so as not to damage the battery because of over-discharge; and, the under-voltage protection value may be set via software; 4 . Si ze s ma l l an d c omp a ct , 7 .7 ( len gt h ) x 5 .1 ( h ei gh t ) x 2 .2 ( w i d t h ) ( cm) , l o w req u i r em en t s i n s p ac e; an d , t h e y ma y b e p la ced i n s ma ll s p ace . II. Installation instructions and procedures Precautions: Please strictly follow the signs and the order of connection, otherwise, the controller may have error or damage. The connection between the battery and the controller should be as short as possible (1~2m), and must choose the right diameter (more than 2mm2), so as to reduce loss.
off on on on on off non-optically-controlled mode controller model error, please reset off off off on off on off flashing flashing charge under-voltage under-voltage + charge

connect the cathodes of load, battery and solar panel in turns. If properly connected, corresponding indicators on the controller will light up; otherwise, check all the connections. 3) Upon the completion of the wiring, the controller will enter into corresponding working condition based on the current voltage of battery/solar panel and operating parameters.

The indicators corresponding to the working status of the controller are respectively shown in the table below
Idle Indicator (green) flashing on off Charge Indicator (green) off off off Discharge Indicator (red) off off on Operating Mode idle wait for discharging discharge

III. P ara met er s etti ngs of c ont r ol l er: (c onf i gur ed via c omp ut er s oft war e, a nd f or deta il s, s ee t he In struc tions fo r Sof t ware ) DT12/2405LI-A, DT12/2410LI-A and TT12/2420LI-A controllers can be used as general-purpose controllers T h e y c a n b e us e d i n d ep e n de n t l y, or c o mb i n e d wi t h t hr e e - wi r e p o w er c o ns t a nt c ur r e n t s o ur c e t o a c hi e ve t h e p u r p os e of l oa d p o w er r e g ul a t i o n.