SIPROTEC 5 Configuration Mar 11, 2014

1:18 PM

Device: 7UT85 Transf. Prot (2 Wind.) Product code Short: P1F25577 Long: 7UT85-DAAA-AA0-0AAAA0-AC0111-12112A-AAA000-000AA0-CC1BA1-CP3

Housing width: Housing type: Binary inputs: Binary outputs: Current transformers: Voltage transformers: Modules in 19" row 1: Modules in 19" row 2: Number of LEDs: Operation Panel: Key switch: Display type: Front Design: Power Supply: Communication: Communications encryption: Integrated Ethernet port J: Plug-in module position E: Plug-in module position F: Functions: Function points class:

3/6 x 19" Flush mounting 9 12 Relays (3 Standard, 9 Fast, 0 High-Speed, 0 Power) 8 for protection, 4 for measurement and sensitive ground-current detection 4 IO203 , PS201 , IO214 16 Integrated Without Small display Standard DC 60 V-250 V, AC 100 V-230 V

Normal DIGSI 5 and IEC 61850/limited Port is available but not assembled Port is available but not assembled

Base + 20 function points

Note on function-points class The function-points class results from the sum of the function points of the selected functions. You can apply these functions as selected. The device allows also each other selection of functions as long as the sum of the required function points is within the selected function-points class. With the maximum function-points class of 1400 it is possible to activate all the functions in the device. The function-points exceeding 1400 are free of charge. In the engineering phase DIGSI 5 checks that the selected configuration is suitable (capable of running in the device) before loading it to the device.

SIPROTEC 5 Configuration Mar 11, 2014


Miscellaneous: Warranty: Firmware:

1:18 PM

5 years Current version

SIPROTEC 5 Configuration Mar 11, 2014

1:18 PM
Always included Add selected Result Qty. x Value = Points Qty.

Functional scope 7UT85 Transf. Prot (2 Wind.): ANSI Function Abbr.

Hardware quantity structure expandable I/O 21/21N 24 25 27 27 27 32, 37 38 46 46 49 49H 50/51 TD Distance protection Overexcitation protection Synchrocheck, synchronizing function Undervoltage protection, 3-phase Undervoltage protection, positivesequence system Undervoltage protection, universal, Vx Power protection active/reactive power Temperature Supervision Negative sequence overcurrent protection Unbalanced-load protection (thermal) Thermal overload protection Hot spot calculation Overcurrent protection, phases I2> I2 t> , It h, It I> IN> I>>> IN> INs> x 5 = x 20 = x x 5 = 5 = Z<, V</ I>/(V,I) V/f Sync V< V1< Vx< P<>, Q<> x x x x x x 1 x 100 = 25 = 50 = 5 = 5 = 5 = 10 = 10 1x

50N/ Overcurrent protection, ground 51N TD 50HS High speed instantaneous overcurrent protection

50N/ Overcurrent protection, 1-phase 51N TD 50Ns/ 51Ns 50BF 59 59 59 Sensitive ground-current protection for systems with resonant or isolated neutral

Circuit-breaker failure protection, 3-pole CBFP Overvoltage protection, 3-phase Overvoltage protection, positivesequence system Overvoltage protection, negativesequence system V> V1> V2>

x x x x

5 = 5 = 5 = 5 =

SIPROTEC 5 Configuration Mar 11, 2014

1:18 PM
Always included Add selected Result Qty. x Value = Points Qty. x 1 x x x 5 = 5 = 15 = 15 = 5 1x

Functional scope 7UT85 Transf. Prot (2 Wind.): ANSI 59N 67 67N 67Ns Function Overvoltage protection, zero-sequence system Directional overcurrent protection, phases Directional overcurrent protection, ground Dir. sensitive ground-fault detection for systems with resonant or isolated neutral Transient ground-fault function, for systems with resonant or isolated neutral Power-swing blocking Trip circuit supervision Overfrequency protection Underfrequency protection Rate-of-frequency-change protection Lockout Transformer differential protection Differential protection (Node protection for Autotransformer) Restricted ground-fault protection Motor differential protection Automatic voltage control Fault locator, single-ended measurement Synchrophasor measurement (1 PMU can be used for max. 8 voltages and 8 currents) Measured values, standard Measured values, extended: Min, Max, Avg Switching statistic counters x 12 = FL-one PMU I I Node IN I x x x 150 = 25 = 40 = x 15 = Abbr. V0> I>, (V,I) IN>, (V,I) INs>, (V,I) W0p,tr>

67Ns

30 =

68 74TC 81O 81U 81R 86 87T 87T Node 87N T 87M 90V FL PMU

Z/t TCS f> f< df/dt

25 =

x x x

5 = 5 = 5 =

SIPROTEC 5 Configuration Mar 11, 2014

1:18 PM
Always included Add selected Result Qty. x Value = Points Qty.

Functional scope 7UT85 Transf. Prot (2 Wind.): ANSI Function CFC standard CFC arithmetic CFC switching sequences for control applications Inrush current detection External trip initiation Control Fault recording of analog and binary signals Monitoring and supervision Protection interface, serial Circuit Breaker Disconnector 4x 4x x x 3 = 3 = Sum: 15 4x 4x x x 40 = 40 = Abbr.