132KV SUBSTATION

S.NO Description 132KV,1600A,31.5kA for 3 seconds centre post rotating type, double break, 1 motor operated isolator with earth switch 132kv,1600A,31.5kA for 3 seconds centre post rotating type, double break, 2 motor operated isolator and as per your specification 66,6203,7000 Part-I & Part-II 96KV,10kA, gapless metal oxide type lightning arrestors and as per customer 3 specification 66,6203,700 Part -I & PartII 132KV,5000MVA,2000A,31.5kA for 1 second SF6 breaker and as per 4 customer specification No. 66,6203,700 Part-I & Part-II 132KV single phase current transformers with following ratio and burden for incoming feeder and as per customer specification 66,6203,700 Part-I & Part-II Core Ratio Burden Accuracy 5 1 200/1 PS 2 200/1 PS 3 200/1 30VA 5P20 4 200/1 50VA Class I Short time rating 31.5kA for one second Dynamic current rating 80kA

Qty

Unit

3 No's

1 No

9 No's

3 No's

3 No's 132KV single phase current transformers with following ratio and burden for incoming feeder and as per customer specification 66,6203,700 Part-I & Part-II Core Ratio Burden Accuracy 6 1 200/1 PS 2 200/1 PS 3 200/1 30VA 5P20 4 200/1 50VA Class I Short time rating 31.5kA for one second Dynamic current rating 80kA 3 No's

132KV single phase potential transformers with following ratio and burden for incoming feeder and as per customer specification 66,6203,700 7 Part-I & Part-II 132KV/110/3/110/3 Burden core 1:100VA, class-1 Metering Burden core 2:100VA,3P (Protection) 8 Marshalling Box with 24 Terminals 9 132KV Post Insulators NGR,6.6KV,400A,10 Ohms, stainless 10 steel as per customer's specification 66,6203,700 Part-III 6.6KV,630A off load relay panel as per 11 customers specification 66,6203,700 Part-I, Part-II,Part-III 132kV Relay panels as per customer 12 specification 66,6203,700 Part-I,PartII,Part-III 132KV control Panels as per customer 13 specification 66,6203,700 Part-I,PartII,Part-III 6.6KV Unearthed, single core 500 Sq.Mtrs, XLPE insulated aluminium 14 conductor cable (300 Mtrs buried in ground through GI pipe & 900Mtrs buried in ground) 15 100mm GI Pipe 16 TRE-FOIL cable clamp 17 HT Cable marker 18 Miscellaneous items a) LYNX ACSR conductor b) 3'' IPS tube c) 11kV Disc insulator antifog type d) Hard ware for tension insulators e) Rigid bimetal connector suitable for 3'' IPS f) Flexible bimetal connector for 3'' IPS g) Rigid T connector suitable for LYNX conductor h) T connector suitable for 3'' IPS tube on one side and ACSR conductor on the other side i) Earthing a) 50x6 GI strip for equipment earthing b) Saddles 3 No's 4 No's 11 No's

2 No's

2 No's

3 No's

3 No's

2400 300 250 4 175 225 60 6

Mtrs Mtrs No's No's Mtrs Mtrs No's sets

45 No's 45 No's 6 No's

3 No's

1750 Meter 200 No's

c) Earth electrodes GI pipe 100mm Dia, 13mm Thick Ps: We have assumed as per your specification that main grid will be provided by you. Hence we have not considered the same in our scope. J) Lightning Materials: Lightning spike of 19mm dia, 1200mm long GI rod 415V power distribution board with 1No. Incoming 63A draw out type switch fuse unit & 10 No's of draw out type switch fuse unit & 10 No's of out 19 going feeders of 10A draw out type switch fuse units and as per customers specifications 66,6203,700 Part-III brief specification of the equipment

20 No's

5 No's

1 No Wall mounted Lighting distribution board with incoming ELCB and 20 outgoing MCB as per customer specification PART-III 21 Lighting: a) Lighing poles as per drawing No. 6203-EL-VIL -0003 and as per customer's specification Part-III under item 2.3.6 b) Flood Luminares of twin lamp type HPMV of 250 watts along with control gear c) Loop-in and Loop-out Box Dewatering pump sets with DOL 22 starter 23 Control Cables 7x2.5 Sq.mm copper control cables 4x2.5 Sq.mm copper control cables 10x2.5 Sq.mm copper control cables 19x2.5 Sq.mm copper control cables 24 Power cables 3.5C x 50Sq.mm Stranded aluminium conductors XLPE insulated 4x10Sq.mm Stranded Aluminium conductors XLPE insulated 25 Cable Trays Cable tray shall be aluminium and prefabricated type. 400mm width 26 Erection, Testing & Commissioning 27 Civil works

1 No

6 No's

6 No's 6 No's 2 No's 450 Mtrs 4250 Mtrs 700 Mtrs 1250 Mtrs

50 Mtrs 50 Mtrs

500 Mtrs 1 LS 1 LS

Schedule for spares

S.NO Description 1 GOD Spares a) Drive Motor b) Set of bearings (For motor & Centre Post Insulator) c) set of 2 No's of contactors as per M.O.M box d) set of auxillary contacts(8 No + 8 NC ) for GOD. e)set of auxillary contacts(4 NO + 4 NC) for earth switch f)Insulated S.S springs g) Mechanism gear box (With out motor) h) Support Insulator Circuit breaker Spares a) Trip coil b) Close coil c) SF6 gas density monitor d)Support Insulator(1 Pole) e)set of gaskets f) Air compressor motor g)SF6 gas cylinder (11KG) with gas filling trolley Lightning arrestor with all accessories NGR Spares a) NGR support insulators b) Terminal bushing c) Stand off insulator Post Insulator Strain Insulator set Suspension insulator sets Clamps & connector each type

Qty 1 No 1 set 1 set 1 set 1 set 1 set

Unit

1 set 3 No's 6 6 1 1 1 1 No's No's set No set set

3 4

1 No 1 No 1 1 3 3 3 3 2 No No No's No's sets sets sets

5 6 7 8

GUARANTED TECHNICAL PARTICULARS CIRCUIT BREAKERS S.NO 1 a b c d e f g Description GENERAL Name of the Manufacturer Country of Manufacture Type of circuit Breaker Manufacture's type designation Standard applicable Rated Volatage Rated Current i) under normal condition at 40c ii) under site condition at 50c Rated frequency Number of poles wether gang operated whether dead tank Type of installation No. of breaks per pole latching current GUARANTED RATINGS Rated short circuit breaking currents i. symmetrical compnent at rated voltage ii) Asymmetrical breaking current at rated voltage. Rated Making Capacity i. At higher rated voltage ii. At lower rated voltage Maximum total break time under any duty condition for any current upto rated breaking current with limiting conditions of voltage and pressure. closing time Qty Particulars As per list of approved makes India SF6 Gas Insulated as per manufacturers standard \iec-56, 1987 132 2000 2000 50 3 Yes live tank Outdoor one

KV A A Hz

h i j k l m n 2 a

KA KA KA KA

31.5 50 80 80

c d

appr(ms) appr(ms)

60 100

Maximum opening time under any e condition with limiting voltages and pressure. f g h i Maximum close open time under any condition with limiting volatges and pressure. first pole to clear factor Maximum close open time Short time current rating a) 1 second b) 3 second Rated operating duty Maximum breaking capacity under phase kilometric faults and rated TRV characteristics.

appr(ms)

30

ms ms kA kA

30 1.5 160 31.5 31.5 0-0.3sec-CO- 3 min-CO

j k

As per IEC-56,1987

Maximum breaking current under phase opposition conditions Maximum line charging breaking m current Maximum cable charging breaking n current Maximum single capacitor bank o breaking current l Maximum over voltage on switching p transformer on no load and corresponding charging current

appr(A) appr(A) appr(A)

75 315 315

Maximum arc duration and q corresponding current under lock out pressure Maximum temperature rise for main r contacts over an ambient temperature of 50c s Rated voltage & pick up range i) for trip coil ii) for closing coil Normal power consumption at rated t voltage of (watts) i) Trip coil ii) Closing coil Rated pressure and limits of operation u (in Kg per Sq.cm) i) for operating mechanism ii) for extinguishing mechanism v Minimum dead time for i) Three phase reclosing ms ii) Single phase reclosing No. of breaker operations with out w maintenance i) at rated interrupting capacity ii) at 50% of rated interrupted capacity iii) at 50% of rated normal current Dielectric withstands of complete breaker one minute dry and wet power frequency withstand voltage i) Between live terminals and ground ii) Between live terminals with breaker contacts open 1.2/50 micro second impulse withstand voltage i) Between live terminals & ground ii) Between terminals with breaker contacts open Total creepage distance to ground Type of operating mechanism

<30ms at 3.15 KA

less than 55c 110V DC:77.0V-121V DC 110V DC:93.5V-121V DC

2x605 W at 110V DC 2x605 W at 110V DC

15:12-16.5 5:4.0-5.0 at 20c 300 NA

20 40 5000

3 a

KV KV

275 275

KVp KVp

650 650

c d

i) Closing ii) opening 4 Data on SF6 gas a) Qty of SF6 per pole appr b) Guaranteed maximum leakage rate c) Rated pressure of SF6 in operating chamber d) Operating pressure range Gas pressure ratings (at 20c) i) Low pressure at ii) Lock out pressure for opening closing

spring Pneumatic 2 Kg less than 1% per year 5kg/cm at 2 at 20C 4-5kg/cm at 2 at 20C 4.5 kg/cm +/-0.3 4.0 kg/cm +/-0.3 4.0 kg/cm +/-0.3 4.0 kg/cm +/-0.3

GUARANTED TECHNICAL PARTICULARS Disconnect Switch S.NO 1 2 3 4 5 6 a b 7 a b 8 a b 9 9.1 a b 9.2 a b 10 a b 11 Description Manufacturer Type of Designation Three phase or Single phase design Earthing switch incorporated Rated voltage Rated normal current at 45c ambient temperature For coupler bay For others Lightninig impulse withstand voltage 1.2/50 micro sec To earth & between phases Across & open contacts one minute power frequency withstand voltage To earth & between phases Across & open contacts Rated short time current Disconnecting switch for 1 sec for 3 sec Earthing switch coupled with D.C for 1 sec for 3 sec Rated peak short circuit current for disconnecting switch for earthing switch Operating mechanism for disconnecting switch Type Operating voltage -rated/min for operating coil(if any) Motor Rated Power operating coil(if any) Motor Operating time Coil energisation to extinction of arc Coil energisation to disconnection of operating motor Operating mechanism for earthing switch Type Operating voltage -rated/min/max Rated Power Clearances Phase to earth arching distance Qty Particulars

3 Phase yes 132

A A

1600 1600

kVpeak kVpeak

650 750

kVrms kVrms

275 370

kArms kArms kArms kArms kApeak kApeak

31.5 31.5 31.5 31.5 80 80

a b 11 a b 12 a b 13 a b c 14 a

V V W W sec sec

240VAC 220VDC 6 470 less than 6 sec less than 6 sec

V W mm

Manually operated NA NA Furnished later

b c 15 a b 16 17 1 2 3 4 5 a b 6 7 8 9 10 a b c 11 12 13 a b c 14 1 2 3 4 5 a b 6 a b 7 8 9

Phase to phase disatnce in open position mm Furnished later distance between contacts of open disconnector mm Furnished later Support insulators Type Designation of unit Creepage distance mm 25mm/KV Total weight of complete disconnecting switches t Applied standard specifications IEC:129 Guaranted technical particulars of earth switch Manufacturer Type of Designation Type of contacts Fixed & Moving Materials of contact surface E-cu & cu cr Rated short time current for 1 sec kArms 31.5 for 3 sec kArms 31.5 Rated peak short circuit current kApeak 100 Gap between poles mm Power frequency withstand voltage across open gap kV(1min) Lightninig impulse withstand voltage across open gap kVpeak Opening Mechanism Type Operating voltage rated/min V 1 phase,50Hz,240V AC Rated power W Main Dimensions mm Total weight kg Type test certificate details Testing station/authority Certificate number Applied standards IEC:129 Creepage distance Guarantee Technical Particulars of Potential Transformer Manufacturer Type of Designation Rated frequency Hz 50 Highest system voltage kV 132 Rated insulation level Power frequency withstand voltage kV 275 Impulse 1.2/50 micro-sec withstand voltage kV(peak) 650 Rated voltages: Rated Primary voltage kV 132/sqrt3 Rated secondary voltage V 110/sqrt3 Rated output/accuracy class winding 1: 100VA, CL-1 winding 2: 100VA, CL-3P Voltage factor 1.2 continuous, 1.5 for 30 sec Rated ratio KV/V 110/sqrt3, 110/sqrt3

IEC 186.1987 10 Applied standard specifications Guarantee Technical Particulars of Current Transformer 1 Manufacturer 2 Type of Designation kV 132 3 Highest system voltage Insulation 4 5 Rated insulation levels Lightning impulse withstand voltage a 1.2/50 micro-sec kVpeak 650 one minute power frequency withstand b voltage kVrmsd 275 6 Rated primary current A 200 a For incomer feeder bay A 100 b For transfomer feeder bay NA c For coupler bay 7 Rating of secondary windings A a Rated current Rated output/accuracy class: Incomer b feeder -core 1(Porotection) VA 200/1 PS -core 2(Porotection) VA 200/1 PS -core 3(Porotection) VA 200/1 5P20 30 -core 4(Measuring) VA 200/1 5P20 30 Rated output/accuracy class : c Transformer feeder) -core 1(Porotection) VA 200/1 PS -core 2(Porotection) VA 100/1 PS -core 3(Porotection) VA 100/1 PS -core 4(Porotection) VA 100/1 5P20 30 -core 5(Measuring) VA 100/1 1 50 Over load capacity at 45c ambient 8 temperature 65c mm 9 Creepage distance mm 10 Flash-over distance mm 11 Dimensions kg 12 Total weight IEC 185,1987 13 Applied standard specifications Guarantee Technical Particulars of Lightning Arrestor 1 Manufacturer 2 Type kV 132 3 Continuous operating voltage kA 10 4 Arrester current rating Yes 5 Outdoor type Pedestal 6 Type of mounting Radio interference voltage at rated 7 voltage to earth mVolts Not applicable Max peak residual voltage of complete 8 arresters at Lightning impulse (8/20ms) 10kA kVpeak 9 Discharge current withstand strength kApeak 9.1 High current (4/10ms) kApeak 0.6 9.2 Low current (2000 ms)

10 Energy impulse capability 11 Pressure relief capability for 0.2 sec Leakage current through arrester at 12 phase voltage 13 Creepage distance 14 Discharge class as per IEC 15 Mass of each complete arrester Max crest of the long time impulse 16 current which the series resistance blocks withstan 17 Dimensions

kJ/kV kA mA mm kg

5 40 1000

50