PacDrive Controller C400 is a Pentium M based controller using the VxWorks real-time operating system. It synchronizes, coordinates and generates the positioning functions for a maximum of 16 servo drives which are connected through the motion bus SERCOS interface. For HMI functions various standard HMI systems can be used.
PacDrive Controller C400 is a Pentium M based controller using the VxWorks real-time operating system. It synchronizes, coordinates and generates the positioning functions for a maximum of 16 servo drives which are connected through the motion bus SERCOS interface. For HMI functions various standard HMI systems can be used.
PacDrive Controller C400 is a Pentium M based controller using the VxWorks real-time operating system. It synchronizes, coordinates and generates the positioning functions for a maximum of 16 servo drives which are connected through the motion bus SERCOS interface. For HMI functions various standard HMI systems can be used.
No. ETIE 098-02 / 2006-03-08 PacDrive TM Controller C400 Controller-based architecture The PacDrive Controller C400 is a Pentium M based controller using the VxWorks real-time operating system that provides logic and motion functions for a production or packaging machine. A PacDrive Controller synchronizes, coordinates and generates the positioning functions for a maximum of 16 servo drives which are connected through the motion bus SERCOS interface. Several standardized field bus interfaces are available, PROFIBUS DP, CAN, CANopen or DeviceNet. For HMI functions various standard HMI systems can be used. Whether low-cost text display or IPC - no problem for the flexible C400. The technical data at a glance: CPU: Intel Pentium M, 600 MHz, 256 MB RAM Real-time operating system: VxWorks IEC 61131-3 programming languages for PLC and motion control Motion bus: SERCOS interface Field bus interface: Profibus DP, CAN, CANopen or DeviceNet Integrated IOs: digital inputs, digital outputs, analog inputs, analog outputs, interrupt inputs, fast touchprobe inputs Communication interfaces: RS 232, RS 485, Ethernet (TCP/IP) CompactFlash TM Disk (32 MB) OPC server for Windows based HMI available Remote diagnosis over modem P D _ T I _ C 4 0 0 _ 0 P D I _ u s . F M page 2 PacDrive Controller C400 ELAU AG Contents K o r r e k t u r a u s d r u c k Product information 1 Technical Data 3 Interfaces 7 Electrical Connections 9 Dimensions 17 All rights reserved to ELAU AG, also in case of patent right applications. No part of this documentation and the related software and firm- ware may be reproduced, rewritten, stored on a retrieval system, transmitted or translated into any other language or computer lan- guage without the express written consent of ELAU AG. Every possible measure was taken to ensure that this product documentation is complete and correct. However, since hardware and software are continuously improved, ELAU makes no repre- sentations or warranties with respect to the contents of this product documentation. PacDrive is a registered trademark of ELAU AG. All other trademarks mentioned are the exclusive property of their manufacturers. This Technical Data Sheet does not replace the Operating manual. For a complete description of the PacDrive Controller see the Operating manual PacDrive Controller For planning and project activities see the PacDrive Projecting manual ELAU AG Dillberg 12 D-97828 Marktheidenfeld Phone: 09391/606-0 Fax: 09391/606-300 eMail: info@elau.de Internet: http://www.elau.de Contents Trademark Imprint P D _ T I _ C 4 0 0 _ 1 T D A _ u s . F M ELAU AG PacDrive Controller C400 page 3 Technical Data K o r r e k t u r a u s d r u c k Technical Data Parameter Value Product configuration Product ID code - C400 up to 16 SERCOS devices (SERCOS devices = MC-4, SCL, PS-4) PacDrive C400 / 10 / 1 / 1 / 1 / 00 Order code - C400 up to 16 SERCOS devices 13 13 02 61 Processor CPU Intel Pentium M 600 MHz RAM 256 MB L2 Cache 1 MB NVRAM 128 kB CompactFlash TM Disk 32 MB Real time clock (RTC) yes (Battery, service intervall 5 years) Watchdog yes (max. 60 V < 2 A) Diagnostics alpha numeric diagnostic display, status LEDs Operating System Real-time operating system VxWorks Programming languages Programming languages IEC 61131-3 Continuous Function Chart (CFC) Function Block Diagram (FBD) Instruction List (IL) Ladder Diagram (LD) Sequential Function Chart (SFC) Structured Text (ST) Interfaces Communication interfaces COM1 COM2 RS232 (X17) RS485 (X18) Network interface Ethernet (10/100 Base-T) (X10) Fieldbus interfaces PROFIBUS DP Master/Slave (12 MBaud) (X20) or CAN (2.0A) resp. CANopen (X19) DeviceNet Slave (cable adapter required) Motion bus interface SERCOS interface (16 MBaud) (X14, X15) PacNet interface 2 PacNet interfaces (X12, X13) Encoder interface 1 SinCos encoder or 1 incremental encoder (X11) P D _ T I _ C 4 0 0 _ 1 T D A _ u s . F M page 4 PacDrive Controller C400 ELAU AG Technical Data K o r r e k t u r a u s d r u c k HMI interface Operator panels: RS485 using Modbus or PROFIBUS DP HMI software tools: OPC server (Windows NT/ 2000/XP or Windows CE) Remote Diagnostics interface Modem Communication protocols http, ftp, SMTP (email) Integrated trace recorder (software oscilloscope) 8 channels 1 ms resolution Integrated logger for diagnostic messages 27 kB Performance Motion performance 8 Servo axes @ 1 ms SERCOS cycle 12 Servo axes @ 2 ms SERCOS cycle 16 Servo axes @ 4 ms SERCOS cycle max. 255 cam profiles running in parallel PLC performance 7 s for 1000 Bit instructions unlimited number of PLC tasks PLC task types: continuous, periodic or event- triggered Cycle time Fast Task: 250 s Nominal I/O response time: 500 s (reading input, processing data, setting output) PLS Programmable limit switches (PLS) max. 256 Type: dynamic Outputs: memory or digital outputs Inputs: external master encoder, virtual master encoder, or axes position Scan time: 250 s I/Os Integrated digital inputs (X3) number: 20 (IEC61131-2) range U IN 0 state: DC 0 ... 6 V range U IN 1 state: DC 20 ... 33 V input current: I IN = 5 mA on U IN = 24 V pole safe: yes input filter: 1or 5 ms programmable Parameter Value P D _ T I _ C 4 0 0 _ 1 T D A _ u s . F M ELAU AG PacDrive Controller C400 page 5 Technical Data K o r r e k t u r a u s d r u c k Integrated analog inputs (X5) number: 2 range U IN : -10 ... 10 V (impedance 100 k) or range I IN : 0 ... 20 mA (impedance 500 R) Integrated interrupt inputs (X4) number: 4 (IEC61131-2) range U IN 0 state: DC 0 ... 6 V range U IN 1 state: DC 20 ... 33 V input current: I IN = 5 mA on U IN = 24 V pole safe: yes input filter: 0.1 or 1 ms programmable Integrated touchprobe inputs (X4) number: 16 (IEC61131-2) range U IN 0 state: DC 0 ... 6 V range U IN 1 state: DC 20 ... 33 V input current: I IN = 5 mA on U IN = 24 V pole safe: yes input filter TP0 to TP15: 100 s resolution time TP0 to TP15: 10 s Integrated digital outputs (X2) number: 16 (IEC61131-2) output voltage: (+UL-3 V) < U OUT < +UL rated current: I e = 250 mA per output switch current: I emax < 2 A for 1 s leakage current 0 signal: < 0.4 mA transmission time: 100 s short-circuit-proof: yes supply output: DC 24 V (-15%/+25%) / 3A Integrated analog outputs (X5) number: 2 range U OUT : -10 ... 10 V (impendance 100 k) Additional digital and analog I/Os via fieldbus max. 3.584 Bytes digital/analog inputs and max. 3.584 Bytes digital/analog outputs max. number of stations: 126 (PROFIBUS) Additional fast digital I/Os via PacNet max. 128 inputs and 128 outputs Additional touchprobe inputs via PacNet max. 128 touchprobe inputs Power supply Power supply DC 24 V (-15% / +25%) / max. 2.5 A without UPS and 4.0 A with UPS Power consumption max. 85 W Uninterruptable power supply UPS yes (optional), (service interval 3 years) Parameter Value P D _ T I _ C 4 0 0 _ 1 T D A _ u s . F M page 6 PacDrive Controller C400 ELAU AG Technical Data K o r r e k t u r a u s d r u c k Environment Product size Box size see chapter Dimensions width: 130 mm height: 400 mm depth: 300 mm Product weight Boxed weight 3.5 kg 4.1 kg Ambient conditions - protection class - ambient temp. - insulation class - rel. humidity IP20 +5...+55 C (in operation without UPS) +5...+40 C (in operation with UPS) -25...+70 C (for storage and transport without UPS) -25...+50 C (for storage and transport with UPS) degree of pollution 2 ..., no dewing allowed 5% ... 85% climatic category 3K3 EN 60 721 Approval Approvals CE, UL , cUL Parameter Value P D _ T I _ C 4 0 0 _ 2 I N T _ u s . F M ELAU AG PacDrive Controller C400 page 7 Interfaces K o r r e k t u r a u s d r u c k Interfaces Fig. 2-1: Overview of the PacDrive Controller C400 b a t t e r y b a t t e r y b a t t e r y X 2 1
c f - c a r d b a t t e r y X 2 1
c f - c a r d X15 X14 X1 2 4 V / w d X4 t p / f a s t X5 X2 d i g i t a l
o u t a n a l o g
i n / o u t X17 X10 c o m 1
r s 2 3 2 X18 c o m 2
r s 4 8 5 X11 X19 X12 X13 X20 p a c n e t p h y s
e n c c a n p r o f i b u s
d p e t h X3 d i g i t a l
i n M a d e
i n
G e r m a n y b a t t e r y b a t t e r y X 2 1
c f - c a r d X 2 1
c f - c a r d enter P a c D r i v e bus err wd pow err C 4 0 0 X18 COM 2 serial interface RS485 X10 ethernet X14 motion bus SERCOS *) IN X15 motion bus SERCOS *) OUT X19 CAN X11 master encoder SinCos or incremental PD_Anschlussbersicht_C400_us.FH8 shield connection X17 COM 1 serial interface RS232 X12 pacnet 0 X13 pacnet 1 X20 profibus dp power supply X1 and watchdog digital outputs X2 digital inputs X3 touchprobe X4 and fast inputs analog in-/outputs X5 *) max. stud torque 0,8 Nm P D _ T I _ C 4 0 0 _ 2 I N T _ u s . F M page 8 PacDrive Controller C400 ELAU AG Interfaces K o r r e k t u r a u s d r u c k P D _ T I _ C 4 0 0 _ 3 C O N _ u s . F M ELAU AG PacDrive Controller C400 page 9 Electrical Connections K o r r e k t u r a u s d r u c k Electrical Connections X1 - control voltage and watchdog Table 3-1: Electrical connections of C400/ X1 Fig. 3-1: Electrical connections of C400 / X1 input connection CAUTION! Disconnection of control voltage! Risk of data loss or damage to flash disk! Use UPS, and the control voltage of the PacDrive Controller may only be switched off if all files are closed. See also Programming Manual -Reference- Function SysShutdown(). Pin Desig- nation Meaning Range Max. cross section 1 DC +24 V supply voltage - 15% / +25% 1.5 mm 2 2 0 V supply voltage 1.5 mm 2 3 +UL for digital outputs DC +24V -15% / +25% 1.5 mm 2 4 L0 for digital inputs / outputs 1.5 mm 2 5 DC +24 V supply voltage -15% / +25% 1.5 mm 2 6 0 V supply voltage 1.5 mm 2 7 WD watchdog relay 1.5 mm 2 8 WD watchdog relay 1.5 mm 2 1 5 4 8 supply voltage internal supply voltage for digital outputs/inputs input connection of power supply (simplified) X1:1 24V X1:5 24V X1:2 0V X1:6 0V X1:3 +UL X1:4 0VL X1 PD_C4_600_P600_X1_us.fh8 fuse P D _ T I _ C 4 0 0 _ 3 C O N _ u s . F M page 10 PacDrive Controller C400 ELAU AG Electrical Connections K o r r e k t u r a u s d r u c k X2 - digital outputs Table 3-2: Electrical connections of C400 / X2 X3 - digital inputs Pin Desig- nation Meaning Range Max. cross section *) 1 O.00 digital Output 1 1.0 mm 2 2 O.01 digital Output 2 1.0 mm 2 3 O.02 digital Output 3 1.0 mm 2 4 O.03 digital Output 4 1.0 mm 2 5 O.04 digital Output 5 1.0 mm 2 6 O.05 digital Output 6 1.0 mm 2 7 O.06 digital Output 7 1.0 mm 2 8 O.07 digital Output 8 1.0 mm 2 9 O.08 digital Output 9 1.0 mm 2 10 O.09 digital Output 10 1.0 mm 2 11 O.10 digital Output 11 1.0 mm 2 12 O.11 digital Output 12 1.0 mm 2 13 O.12 digital Output 13 1.0 mm 2 14 O.13 digital Output 14 1.0 mm 2 15 O.14 digital Output 15 1.0 mm 2 16 O.15 digital Output 16 1.0 mm 2 *) Stripping length l=9mm; by the wire-end ferrule is the length of the metal ferrule l=10mm Pin Desig- nation Meaning Range Max. cross section *) 1 I.00 digital input 0 DC 0 ... 33 V 1.0 mm 2 2 I.01 digital input 1 DC 0 ... 33 V 1.0 mm 2 3 I.02 digital input 2 DC 0 ... 33 V 1.0 mm 2 4 I.03 digital input 3 DC 0 ... 33 V 1.0 mm 2 5 I.04 digital input 4 DC 0 ... 33 V 1.0 mm 2 6 I.05 digital input 5 DC 0 ... 33 V 1.0 mm 2 7 I.06 digital input 6 DC 0 ... 33 V 1.0 mm 2 8 I.07 digital input 7 DC 0 ... 33 V 1.0 mm 2 9 I.08 digital input 8 DC 0 ... 33 V 1.0 mm 2 10 I.09 digital input 9 DC 0 ... 33 V 1.0 mm 2 11 I.10 digital input 10 DC 0 ... 33 V 1.0 mm 2 12 I.11 digital input 11 DC 0 ... 33 V 1.0 mm 2 1 9 8 16 1 11 10 20 P D _ T I _ C 4 0 0 _ 3 C O N _ u s . F M ELAU AG PacDrive Controller C400 page 11 Electrical Connections K o r r e k t u r a u s d r u c k Table 3-3: Electrical connections of C400 / X3 X4 - touchprobe and fast digital inputs Table 3-4: Electrical connections of C400 / X4 13 I.12 digital input 12 DC 0 ... 33 V 1.0 mm 2 14 I.13 digital input 13 DC 0 ... 33 V 1.0 mm 2 15 I.14 digital input 14 DC 0 ... 33 V 1.0 mm 2 16 I.15 digital input 15 DC 0 ... 33 V 1.0 mm 2 17 I.16 digital input 16 DC 0 ... 33 V 1.0 mm 2 18 I.17 digital input 17 DC 0 ... 33 V 1.0 mm 2 19 I.18 digital input 18 DC 0... 33 V 1.0 mm 2 20 I.19 digital input 19 DC 0 ... 33 V 1.0 mm 2 *) Stripping length l=9mm; by the wire-end ferrule is the length of the metal ferrule l=10mm Pin Desig- nation Meaning Range Max. cross section *) 1 T.00 touchprobe input 0 DC 0 ... 33 V 1.0 mm 2 2 T.01 touchprobe input 1 DC 0 ... 33 V 1.0 mm 2 3 T.02 touchprobe input 2 DC 0 ... 33 V 1.0 mm 2 4 T.03 touchprobe input 3 DC 0 ... 33 V 1.0 mm 2 5 T.04 touchprobe input 4 DC 0 ... 33 V 1.0 mm 2 6 T.05 touchprobe input 5 DC 0 ... 33 V 1.0 mm 2 7 T.06 touchprobe input 6 DC 0 ... 33 V 1.0 mm 2 8 T.07 touchprobe input 7 DC 0 ... 33 V 1.0 mm 2 9 T.08 touchprobe input 8 DC 0 ... 33 V 1.0 mm 2 10 T.09 touchprobe input 9 DC 0 ... 33 V 1.0 mm 2 11 T.10 touchprobe input 10 DC 0 ... 33 V 1.0 mm 2 12 T.11 touchprobe input 11 DC 0 ... 33 V 1.0 mm 2 13 T.12 touchprobe input 12 DC 0 ... 33 V 1.0 mm 2 14 T.13 touchprobe input 13 DC 0 ... 33 V 1.0 mm 2 15 T.14 touchprobe input 14 DC 0 ... 33 V 1.0 mm 2 16 T.15 touchprobe input 15 DC 0 ... 33 V 1.0 mm 2 17 F.00 fast input 0 DC 0 ... 33 V 1.0 mm 2 18 F.01 fast input 1 DC 0 ... 33 V 1.0 mm 2 19 F.02 fast input 2 DC 0 ... 33 V 1.0 mm 2 20 F.03 fast input 3 DC 0 ... 33 V 1.0 mm 2 *) Stripping length l=9mm; by the wire-end ferrule is the length of the metal ferrule l=10mm Pin Desig- nation Meaning Range Max. cross section *) 1 11 10 20 P D _ T I _ C 4 0 0 _ 3 C O N _ u s . F M page 12 PacDrive Controller C400 ELAU AG Electrical Connections K o r r e k t u r a u s d r u c k X5 - analog in- /outputs Fig. 3-2: Electrical connections of C400 / X5 Fig. 3-3: Electrical connections of C400 / X5 input connection Pin Desig- nation Meaning Range Max. cross section *) 1 AI.0 + analog input 0 1.0 mm 2 2 J.0 + Br. current input 0 + 1.0 mm 2 3 AI.0 - analog input 0 - 1.0 mm 2 4 A.GND analog ground 1.0 mm 2 5 12 V Out 0 output voltage 0 12 V 1.0 mm 2 6 PE shield 1.0 mm 2 7 AO.0 analog output 0 -10 ... +10 V 1.0 mm 2 8 A.GND analog ground 1.0 mm 2 9 PE shield 1.0 mm 2 10 AI.1 + analog input 1 1.0 mm 2 11 J.1 + Br. current input 1 + 1.0 mm 2 12 AI.1 - analog input 1 - 1.0 mm 2 13 A.GND analog ground 1.0 mm 2 14 12 V Out 1 output voltage 1 12 V 1.0 mm 2 15 PE shield 1.0 mm 2 16 AO.1 analog output 1 -10 ... +10 V 1.0 mm 2 17 A.GND analog ground 1.0 mm 2 18 PE shield 1.0 mm 2 *) Stripping length l=9mm; by the wire-end ferrule is the length of the metal ferrule l=10mm 1 10 9 18 X5 input connection of analog inputs (simplified) channel 1 X5:3 AI.0- X5:12 AI.1- X5:1 AI.0+ X5:10 AI.1+ X5:4 X5:5 X5:6 X5:2 J.0+ X5:11 J.1+ X5:8 X5:14 X5:9 PE (shield) +12V + - + - +12V R1 R1, R2 = 500R R3 - R8 = 1k R4 R3 R5 R2 j1 j2 R7 AGND R8 channel 2 PD_C4_600_X5_AnaIn_us.fh8 R6 P D _ T I _ C 4 0 0 _ 3 C O N _ u s . F M ELAU AG PacDrive Controller C400 page 13 Electrical Connections K o r r e k t u r a u s d r u c k X10 - ethernet Table 3-5: Electrical connections of C400 / X10 NOTE Depending on the application, different cables are required for the connection to the PacDrive Controller via the RJ-45 connector plug. Connection PacDrive Controller <-> corporate network mit RJ-45 -> straight twisted-pair cable Connection PacDrive Controller <-> Hub -> straight twisted-pair cable Connection PacDrive Controller <-> PC -> crossover twisted-pair cable In doubt, please contact your network administrator. X11 - master encoder (SinCos) Table 3-6: Electrical connections of C400 / X11 1 8 Pin Desig- nation Meaning Range Max. cross section 1 Tx+ OutputTransmitData+ 2 Tx- OutputTransmitData- 3 Rx+ InputReceiveData + 4 - reserved 5 - reserved 6 Rx- InputReceiveData - 7 - reserved 8 - reserved LED yellow:link (light on) / Aktivity (flash or flicker) LED green: type of connection 10MBit (light off) / 100MBit (light on) 1 5 6 9 Pin Desig- nation Meaning Range Max. cross section 1 REFSIN sinus reference signal 0.25 mm 2 2 SIN sinus trace 0.25 mm 2 3 REFCOS cosine reference signal 0.25 mm 2 4 COS cosine trace 0.25 mm 2 5 +9 V supply voltage 0.25 mm 2 6 RS485- parameter channel - 0.25 mm 2 7 RS485+ parameter channel + 0.25 mm 2 8 SC_SEL encoder connected (bridge to GND) 0.25 mm 2 9 GND supply voltage 0.25 mm 2 P D _ T I _ C 4 0 0 _ 3 C O N _ u s . F M page 14 PacDrive Controller C400 ELAU AG Electrical Connections K o r r e k t u r a u s d r u c k X11 - master encoder (incremental) Table 3-7: Electrical connections of C400 / X11 CAUTION! Disconnection of master encoder plug while unit is powered on! Master encoder may be damaged! Disconnect and connect the master encoder plug only in voltage- free state (disconnect MotorController from 24 V power supply!). X12/13 - PacNet Table 3-8: Electrical connections of C400 / X12, X13 NOTE Only use permitted PacNet cables with the PacNet interface to avoid malfunction. 1 5 6 9 Pin Desig- nation Meaning Range Max. cross section 1 _UA track A 0.25 mm 2 2 UA track A 0.25 mm 2 3 _UB track B 0.25 mm 2 4 UB track B 0.25 mm 2 5 + 5 V supply voltage 0.25 mm 2 6 _UO track O 0.25 mm 2 7 UO track O 0.25 mm 2 8 - reserved 0.25 mm 2 9 GND ground 0.25 mm 2 1 8 8 1 Pin Desig-nation Meaning Range Max. cross section 1 TxD+ OutputTransmitData+ 2 TxD- OutputTransmitData- 3 RxD+ InputReceiveData+ 4 TxC- OutputTransmitClock- 5 TXC+ OutputTransmitClock+ 6 RxD- InputReceiveData- 7 RxC+ InputReceiveClock+ 8 RxC- InputReceiveClock- P D _ T I _ C 4 0 0 _ 3 C O N _ u s . F M ELAU AG PacDrive Controller C400 page 15 Electrical Connections K o r r e k t u r a u s d r u c k X17 - Com 1 (RS 232) Table 3-9: Electrical connections of C400 / X17 X18 - Com 2 (RS485) Table 3-10: Electrical connections of C400 / X18 X19 - CAN Table 3-11: Electrical connections of C400 / X19 1 5 6 9 Pin Desig- nation Meaning Range Max. cross section 1 DCD Data Carrier Detect 0.25 mm 2 2 RxD Receive Data 0.25 mm 2 3 TxD Transmit Data 0.25 mm 2 4 DTR Data Terminal Ready 0.25 mm 2 5 GND Signal Ground 0.25 mm 2 6 DSR Data Set Ready Clear To Send 0.25 mm 2 7 RTS Request To Send 0.25 mm 2 8 CTS Clear To Send 0.25 mm 2 9 RI Ring Indicator 0.25 mm 2 1 5 6 9 Pin Desig- nation Meaning Range Max. cross section 1 +5 VM supply voltage 0.25 mm 2 2 TxD- RS485 Transmit - 0.25 mm 2 3 TxD+ RS485 Transmit+ 0.25 mm 2 4 RxD+ RS485 Receive + 0.25 mm 2 5 RxD- RS485 Receive - 0.25 mm 2 6 GNDR GND receive RS485 0.25 mm 2 7 - reserved 0.25 mm 2 8 GNDM supply voltage 0.25 mm 2 9 GNDR GND receive RS485 0.25 mm 2 1 5 6 9 Pin Desig- nation Meaning Range Max. cross section 1 - reserved 0.25 mm 2 2 CAN_L bus line (low) 0.25 mm 2 3 GND ground 0.25 mm 2 4 - reserved 0.25 mm 2 5 - reserved 0.25 mm 2 6 - reserved 0.25 mm 2 7 CAN_H bus line (high) 0.25 mm 2 8 - reserved 0.25 mm 2 9 - reserved 0.25 mm 2 P D _ T I _ C 4 0 0 _ 3 C O N _ u s . F M page 16 PacDrive Controller C400 ELAU AG Electrical Connections K o r r e k t u r a u s d r u c k X20 - profibus db Table 3-12: Electrical connections of C400 / X20 1 5 6 9 Pin Desig- nation Meaning Range Max. cross section 1 PE shield 0.25 mm 2 2 - reserved 0.25 mm 2 3 RxD / TxD -P data -P 0.25 mm 2 4 CNTR-P control signal P 0.25 mm 2 5 DGND signal ground 0.25 mm 2 6 VP control voltage 0.25 mm 2 7 - reserved 0.25 mm 2 8 RxD / TxD -N data -N 0.25 mm 2 9 reserved 0.25 mm 2 P D _ T I _ C 4 0 0 _ 4 D I M _ u s . F M ELAU AG PacDrive Controller C400 page 17 Dimensions K o r r e k t u r a u s d r u c k Dimensions Fig. 4-1: Dimensions of the PacDrive C400 ca. 235 (9.25) ca. 260 (10.23) max. depth incl. connectors! PDM_C400_Masszeichnung_us.FH8 X17 c o m 1
( 0 . 2 8 ) b a tte ry b a tte ry b a tte ry X 2 1 c f-c a rd b a tte ry X 2 1 c f-c a rd X15 X14 X1 2 4 V /w d X4 tp /fa s t X5 X2 d ig ita l o u t a n a lo g in /o u t X17 X10 c o m 1 r s 2 3 2 X18 c o m 2 r s 4 8 5 X11 X19 X12 X13 X20 p a c n e t p h y s e n c c a n p r o fib u s d p e th X3 d ig ita l in M a d e in G e r m a n y b a tte ry b a tte ry X 2 1 c f-c a rd X 2 1 c f-c a rd enter P a c D r i v e bus err wd pow err C 4 0 0 ELAU On the best machines