II.

Thermal insulation design for the envelop elements


The equation used for the thermal resistance estimation in the hypothesis of one direction thermal flux is:

Ro ,ef = Ri + Rk + Re =

dk

[m2K/W]

(1)

Thermal characteristics of the materials used in the construction of the envelope:


Density Nr. Material Kg/m3 2 2500 2400 1700 1200 100/130 20 700 1600 1800 675 625 550 800 300 600 Thermal conductivity W/(mk) 3 1,74 1,62 0,87 0.52 0,04 0,04 0,23 0,58 0,70 0,27 0,25 0,17 0,23 0,07 0,17 Vapour Thermal receptivity permeability resistance 1/KD Sm 2 W/(m k) 4 5 16,25 21,63 15,36 21,3 4,47 8,5 3.15 4.7 0,50 1,3 0,29 30,0 3,13 3,4 7,50 3,9 8,74 2,4 3,38 3,13 4,12 5,78 1,95 3,28 3,8 3,7 10,4 11,3 2,7 -

0 1 2 3 4 5 6 7 8 10 11

12 13 14 15 16

1 Reinforced concrete Reinforced concrete Cement/lime plaster Plaster over insulation Mineral wool Polystyrene Cardboard plaster Sand infilling Gravel infilling Aerated concrete (b.c.a.) masonry with slim joints Aerated concrete strips Fir timber Oak and beech timber PFL board Bituminous cardboard

Other necessary information : Surface heat loss factors: i and e:

Working condition factor:

One requirement for the thermal resistance is:

Ro,ef Rnec

Where the corrected mean resistance for building envelope are : Ro,nec= 1.4 for external walls Ro,nec= 3 for terace roof Ro,nec= 1.65 for over basement

1. External walls type I (cross shear wall):

Ro ,ef = Ri + Rk + Re =
i=8, e=24
Nr. Material

dk

e
Therm.a sim. factor Sm (W/m2K) Heae loss resist. R (m2K/W) Vapour conducti v. 1/KD -

Layer Therm. Thicknes conduct. s d (m) (W/mK)

Internal Cement / lime 1 plaster 2 Reinforced concrete 3 Polystyrene 4 External plaster Total on element

External walls:

type II

Nr.

Material

Layer Therm. Thicknes conduct. s d (m) (W/mK)

Therm.a sim. factor

Heae loss resist.

Vapour conducti v. 1/KD -

Sm R 2 2 (W/m K) (m K/W)

Internal Cement / lime plaster Cellular concrete (b.c.a.) or brick 2 masonry 3 Polystyrene 4 External plaster Total on element 1

2. Top floor (terrace roof) : 1- waterproof membrane protection (mortar 3 cm + gravel or concrete boards); 2 waterproof membrane; 3 diffusive layer; 4 waterproof membrane support (mortar 3 cm); 5 plistyrene termoinsulation 20 cm; 6 vapor barrier; 6 membrane support (mortar 3 cm) 7 diffusion layer; 7 membrane support (mortar 3 cm) 8 sloping layer (b.c.a.) 8 cm; 9 reinforced concrete floor slab 1215 cm; 10 ceiling plaster 1,5 cm; 3. Floor over the basement:

11

floor over basement: 1- ceiling plaster - 1,5 cm; 2- thermal insulation of polystyrene 10 cm; 3- reinforced concrete floor slab 1215 cm; 4- mortar bead 3 cm 5 Ceramic floor tile 1.2 cm