Cable Support Systems

Cable Trays and


Integrated Ceilings

06
Index
Cable trays & accessories page page page page
Bends, Junctions, Risers Cantilever arms Fixings Support brackets
Adjustable bend W10/40 30 Adjustable cantilever arm W1840 23 Torxbits 132 Support bracket W1940 25
Adjustable bend W10/60 54 Adjustable cantilever arm W1860 48 Support bracket W1960 49
90° Bend W10/40 32 Cantilever arm 50L, 50 80-81 Installation summeries Support bracket W20 70
90° Bend W10/60 56 Cantilever arm 80 82 Cable trays 14-15 Support bracket W20A 70
90° Bend W10F/40 33 Internal cantilever arm W17/40 22 Installation tray W4 74 Support bracket/joint W7/40 24
90° Bend W4 77 Suspension components 16-17 Support bracket/joint W7/60 50
T-joint W9/40 27 Cantilever arms – accessories
T-joint W9/60 52 Back plate W30 83 Joints Surface treatment
T-joint W29/40 28 Mounting rail 40 84 Joint W2 76 Corrosion classes 7
T-joint W29/60 53 Wall bracket 80 83 Side joint W49/40 26 Current load of cables 9
T-junction W12/40 34 Side joint W49/60 51 Environment/Quality 9
T-junction W12/60 57 Ceiling brackets Potential balancing 12
T-junction W12F/40 35 Ceiling attachment W31 98 Junction box plates Product certificates 10-11
X-junction W13/40 36 Ceiling bracket 5 93 Junction box plate W24/40 44 Surface treatments 8
X-junction W13/60 58 Ceiling bracket 7 88 Junction box plate W24/60 63
X-junction W13F/40 37 Ceiling bracket WN16 109 Tele-conduits
Vertical riser W11/40 31 Lashing wires Tele-conduit 36 with knock-out holes 113
Vertical riser W11/60 55 Clamps Lashing wire 108
Vertical riser W4, interior 78 Cover clamp W62 115 Integrated ceilings & accessories
Vertical riser W4, exterior 79 Earth clamp W79 109 Mesh trays Integrated ceilings 146
Locking clamp W77 98 Wibe Defem system. See sep. brochure Acoustic lamina 147
Reducers
Reducer W28/40 26 Covers Mounting rails Installation summaries
Reducer W28/60 51 Cover plate W16 110 Mounting rail 40 84 Ceilings in corridor 151
Reducing piece W14/40 left 38 Cover strip W47/60 66 Mounting rail WMS25 84 Ceilings with sound baffles 149
Reducing piece W14/40 left Hdg 39 Cover W5 114 Ceilings with wire baskets 150
Reducing piece W14/40 right 40 End cover W45/40 29 Ogebe fixings Open ceilings 148
Reducing piece W14/40 right Hdg 41 End cover W45/60 62 Fixings Ogebe 141 Sound baffles 152
Reducing piece W14/60 left 59 Ogebe fixing type E 142 Wire baskets 153
Reducing piece W14/60 right 60 Dividers Ogebe fixing type D 143 W-swing in corridor 159
Reducing piece W15/40 straight 42 Dividing strip 39 111 Ogebe fixing type ED 144
Reducing piece W15/40 straight Hdg 43 Dividing strip 39/55 64 Ogebe fixing type Eg 145 Sound baffles
Reducing piece W15/60 straight 61 Insert piece W39 112 Sound baffles - accessories 155-158
Insert piece W39/55 65 Paint
Brackets Strip fixing W44 117 Anti-corrosive paint “Galvafroid” 118 W-swing ceilings
Angle bracket W8 105 Support band W6 64 and 112 Repair paint 118 Angle strip W46 167
Angle bracket W8S 106 Integrated channel W27/40 166
Bracket 60/40 94 End plugs Pendant/Fixing rails, Vertical pieces Integrated channel W27/60 167
Combi bracket 53 116 End plug 28C,D,E and F 92 Fixing rail 24/26x53 for casting-in 99 Profile W-swing 1/40 160
Cover clamp W62 115 End plug 7 90 Pendant/Fixing rail 24/34 91 Profile W-swing 1/60 160
End bracket WN17 104 Protection strip W48 117 Pendant/Fixing rail 7L,7 88 Profile W-swing 2 161
Luminaire bracket W25/40 45 Pendant rail W32 97 Profile W-swing 3 163
Luminaire bracket W25/60 65 Fixings Pendant strip W33 96 Profile W-swing 4A 164
Luminaire bracket W35 71 Adapter TLF-A12 137 Threaded rod M10 W76 85 Profile W-swing 5 165
Luminaire bracket W50 118 Angled bracket TLF-F12 137 Vertical piece 2 101 Shade ledge W26/40 165
Luminaire bracket W55 72 Bitro adapter 131 Vertical piece 2F 102 Shade ledge W26/60 166
Luminaire bracket W56 72 Bits holder 132 Vertical piece 2FPK 100 Wall bracket W-swing 2 162
Pendant attachment W21 86 Concrete screws 125-129 Vertical piece 20 103 Wall tray W60/40 168
Pendant bar 1 95 Expansion bolts 122 Vertical piece 7L, 7 89 Wall tray W60/60 168
Pendant bracket W80, W81 71 Expansion nail 130
Tube pendant attachment W73 87 Express hanger SVH 138 Screw sets Installation examples
Wall bracket 80 83 Eye screw 130 Expansion bolts 122-123 Installation examples 169
Fixing strips 140 Locking plug W41 120
Cable trays Hammer drill SDS plus 133 Mounting set W78 119
Cable tray W1/40 Pre-galv 18 Hammer tool TLF-S 136 Screw set 22S 119
Cable tray W1/60 Pre-galv 46 Light concrete screw 130 Screw set W34 120
Cable tray W3/40 Hdg 21 Low density anchor TLF 135 Screw set W36 119
Cable tray W3/40 Pre-galv 20 Magnetic socket for Concrete screw 131 Screw set W36C 119
Cable tray W3/60 Pre-galv 47 Mounting tool for Eye screw 130 Screw set W37 120
Ceiling mesh tray WN2 108 Mounting tool SVH-T 139 Screw set W38P 120
Fixing tray N for casting-in 107 Securing spring SVH-L 139 Screw W40 120
Installation tray W4 75 Sleeve TLF-H12 136 Spring nut M8 119
Lighting trunking W70 68 Socket for Concrete screw 131 T-bolt 26F 121
Lighting trunking W71 69 Square peg 132

Wibe reserve the right to make changes to manufacture and design without prior notice.
Cable trays
Cable trays - view 4

Corrosion classes, Surface treatments, Current load of cables 7

Environmental policy and certification, Product certificates, Potential balancing 9

Cable trays – installation summary 14

Suspension components – installation summary 16

Cable tray system W1/40, W3/40 18

Cable tray system W1/60, W3/60 46

Lighting trunking system W70, W71 67

Installation tray system W4 73

Suspension components, common parts

Cantilever arms, Wall bracket, Back plate, Mounting rail 80

Threaded rod, Pendant attachments, Pendant/Fixing rails, Brackets 85

Pendant rails, Ceiling attachment, Vertical pieces 96

End bracket, Angle brackets, Fixing tray N 104

Ceiling mesh tray, Earth clamp, Cover plate, Dividing strip 108

Tele-conduit, Cover W5, Components 113

Screw sets,T-bolt, Expander bolts 119

Fixing system 124

Ogebe fixings 141

Integrated ceilings 146

Installation examples 169

1
Wibe in Mora, Sweden

There is always a next time.

Usually it’s a matter of a few extras, sometimes more radical changes. New and
old have to fit together regardless. Hand in glove – even in 15 years’ time.

We delivered our first – and the world’s first – cable ladder just over 75 years
ago. And we can still supply additions to it if necessary. We carry over 10,000
items in our range. Just over a hundred are ladders and trays. The remainder
consists of components to meet every possible requirement. And some pretty
impossible ones too.

So don’t just think about this time, think about the next time.

We are the biggest supplier on the market. More concretely, we provide cable
ladders and cable trays, lighting trunking and installation rails, steel wire sys-
tems, integrated ceilings – and Defem® mesh trays. We hot dip galvanize in one
of the most modern plants in Scandinavia and do powder coating in one that is
just as technologically advanced.

Wibe is the market leader in telescopic masts and masts for lighting and com-
munication. We have experience from thousands of projects, from planning, to
fitting and erection, to commissioning and service.

Wibe is part of the worldwide Schneider Electric group, which also includes leading brands such as Eljo, Lexel, Merlin Gerin, Telemecanique and Thorsman.

2
3
Cable trays - view

Cable tray W1 Cable tray W3/40

Height 40 and 60 mm Height 40 mm


Length 2000 and 3000 mm Length 3000 mm
Width 70-600 mm Width 50-600 mm
Pre-galvanized Pre-galvanized
Hot dip galvanized Hot dip galvanized
Powder coated white Powder coated white
Electro-galvanized Electro-galvanized
Stainless steel AISI 316 Stainless steel AISI 316

4
Cable trays - view

Cable tray W3/60 Installation tray W4

Height 60 mm Height 15 mm
Length 3000 mm Length 3000 mm
Width 50-600 mm Width 50-400 mm
Pre-galvanized Pre-galvanized
Hot dip galvanized Hot dip galvanized
Powder coated white Powder coated white
Electro-galvanized Electro-galvanized
Stainless steel AISI 316 Stainless steel AISI 316

5
Cable trays - view

Lighting trunking W70, W71 Mesh trays

Wibe Defem system - see separate brochure

Height 22 and 40 mm
Length 3000 and 6000 mm
Width 40-200 mm
Pre-galvanized
Hot dip galvanized
Powder coated white
Electro-galvanized
Stainless steel AISI 316

6
Corrosion classes
The life expectancy of a cable support system is dependent on the The table below shows various corrosion classes. As a guide, we
environment in which it is placed. Therefore, it is important to have included the surface treatment recommended by Wibe for
establish the corrosive properties of an environment to ensure that the different classes.
the right treatment and the right material are chosen. On the next page, we briefly outline the various surface treatments
To achieve this, several corrosion classes have been drawn up in and materials.
accordance with BSK99.

As regards environmental corrosion, a steel design component can usually be assigned to one of the corrosion classes (C1-C5-M)
as shown in table 1:23a. Reference values for the average level of corrosion in steel and zinc are given in table 1:23c.
The corrosion classes comply with those stipulated in SS-EN ISO 12944-2.

Table 1:23a
Corrosion classes as stipulated by SS-EN ISO 12944-2 with atmospheric corrosion levels and examples of the environment in which
they are most suitable for use.

7
Surface treatments
Electro-galvanized Modern painting plant produces perfect results
Some of Wibe’s products are electro-galvanized in accordance with Carefully and thoroughly pre-treating of galvanized products is the
ISO 2081. Such products are intended for use only in warm, dry cornerstone of achieving perfect adhesion.
areas with negligible pollutant levels. We employ a nine-stage process, consisting of alkaline degreasing,
rinsing, rinsing, activation, zinc-manganese phosphatising, rinsing,
Pre-galvanized rinsing, passivation and rinsing with de-ionised water. Immediately
Products are manufactured from Z 275 pre-galvanized sheet steel in after the pre-treatment process, products are dried in a tunnel oven
accordance with SS-EN 10142. Surface sections created during and are then powder coated by an electronically controlled robot,
cutting and drilling will, under normal conditions, repair themselves, guaranteeing that all components are treated perfectly. Finally, the
providing the plant with superb anti-corrosion protection. coating is cured in a 24-section tunnel oven, the temperature in each
section being regulated in a stepless manner, producing a perfect
Hot dip galvanized hardening curve. At no stage in the process does a human hand
Wibe has one of the most modern hot dip galvanization plants in the touch any of the products. Instead, they are moved between the
Nordic countries. The hot dip process is continuous, guaranteeing a various stages using a 355-metre long electronically controlled
high and even quality. conveyor belt. A perfect result! The surface is now resistant to both
Once manufactured products are hot dip galvanized in accordance scratches and impact.
with SS-EN ISO 1461 whilst nuts and bolts are hot dip galvanized in
accordance with SS-EN ISO 10684:2004. This form of galvanization Colour schemes
affords very good value-for-money anti-corrosion protection in As standard, cable trays, lighting trunking, mounting fittings and ac-
atmospheres with a pH value of between 6 and 13. However, in acid- cessories are painted white RAL9003 Gloss 30.
ic environments where pH levels fall below 6 and in alkaline environ- Other colours of your choice can also be offered.
ments where the pH value exceeds 13, the protective zinc layer If the powder-coated surface is broken, e.g. when cutting during
breaks down relatively quickly. mounting, repair paint for minor damages can be supplied.

Quality - Epoxy/polyester
(very high chemical tolerance)
Rate of dissolution Zinc
Epoxy/polyester................(min 70 µm)
Lustre (ISO 2813)..............30
Finish (ISO 1519)...............6 mm
Cross hatch (ISO 2409)
Erichsen test (ISO 1520)....8 mm

Stainless steel
Wibe stainless steel products, manufactured in accordance with
SS 2333 AISI 304, or in accordance with SS 2348 AISI 316L are
designed for use in highly aggressive environments, either indoors or
outdoors, on industrial sites where there are high levels of potent air-
The rate of dissolution is determined by the pH value of pure zinc borne pollution such as in certain chemical industries, cellulose-
in distilled oxygenated water that has been pH adjusted to various related industries, refineries or artificial fertiliser factories, high
levels using HCl or NaOH. humidity tunnels, etc.
NB The curve only applies to conditions shown, and gives only Stainless steel products are also ideal for use in environments where
an indication of the propensity for corrosion without consideration special hygiene requirements are in force, such as dairies, abattoirs,
to time. other food industries and pharmaceuticals factories.

Stainless steel AISI 304 or AISI 316L?


Zinkpox® The deciding factor in choosing between stainless steel AISI 304 or
The Zinkpox® method involves the coating of the zinc layer with AISI 316L is the aggressiveness of the environment in which it is to
a homogenous covering of epoxy/polyester. be used, and for this atmospheric chlorine content plays a significant
Epoxy/polyester is a plastic paint that displays the greatest resis- role. Environments with a high chlorine content - coastal areas
tance to most chemicals. being a prime example - are aggressive and usually require the use
The layer of zinc on the steel prevents the formation of underfilm of AISI 316L materials.
corrosion, which is a contributing factor in paint degradation. When assessing the needs of factories, consideration should be
The paint layer is only affected by atmospheric erosion. given to the materials previously used to suspend equipment such as
The zinc layer only deteriorates once the paint has been eroded, and pipe tubing, and from this determine whether stainless steel AISI 304
this gives you considerable breathing room before the steel is subject or AISI 316L material is required.
to attack.
By using this treatment process, the life expectancy of the product is
more than double that had it only been treated using hot dip galvani-
zation.
In addition to providing excellent anti-corrosion protection, Zinkpox®
also allows freedom of choice as regards product colour. Powder
coating is an extremely environmentally friendly finishing method.
The pigment contains no solvents and has, to a great extent, re-
placed wet finishes.
In the case of visible cable tray installations, both trays and
accessories can be painted in colours matching the décor of their
surroundings.

8
Current load of cables

Installation instructions
Installation
The ladders and trays shall be installed in such a way that, as often Reinforced heavy duty cable ladders
as possible the cables can be laid directly in place rather than being Ladders shall be designed for a uniform load of at least 600 N
pulled through. per 1000 mm ladder length with a distance of 6000 mm between
Ladders and trays for current carrying cables along the ceiling shall brackets/fixings. They shall also be able to carry an occasional point
be installed in such a way that the distance from the top of the ladder load as to the heavy duty ladders.
or tray to the ceiling shall not be less than 300 mm.
The free vertical distance between parallel ladders and trays shall be Heavy duty cable ladders, cable trays
at least 200 mm. Ladders and trays shall be designed for a uniform load of at least
Ladders and trays near walls shall be installed with a minimum free 200 N per 1000 mm ladder length and 100 mm width with a distance
distance of 50 mm to the wall, so that cables can pass between the of 2000 mm between brackets/fixings. They shall also be able to
ladders and the wall. carry an occasional point load of 1000 N with a double safety factor
Ladders and trays along partition walls shall be installed with measured between supporting points 3 and 4 when using an
minimum free distance of 100 mm to the wall. installation with six supporting points.
Sharp edges and screw ends on ladders or trays should be removed
before the cables can be installed. Light duty cable ladders, cable trays
Expansion bolts for the installation of brackets/fixings shall be in- Ladders and trays shall be designed for a uniform load of at least
stalled with such a distance between them, that the designated load 100 N per 1000 mm ladder length and 100 mm width with a distance
for ladders and trays will not be exceeded. When selecting the of 2000 mm between brackets/fixings.
distance between cantilever arms or brackets/fixings, the bearing
strength and designated load of the ladders and trays must be taken
into consideration.

Environmental policy and certification


Management system - Quality and Environment
Environmental product declarations are available for all Wibe
products. These can be ordered direct from Wibe. Wibe has a third-party certified management system
Declarations may also be downloaded from the Wibe website at for quality and environment in accordance with
www.wibe.com ISO 9001:2000 and ISO 14001:2004
Our product sheets and brochures are marked successively with the
name of the environmental document (WEF-0001-). CE-marking of products
is placed on the product or on the packing according to
Environmental policy "Declaration of Conformity" (D o C), applicable to Wibe Cable
AB Wibe shall actively strive to minimise any negative impact its ladders, Cable trays and Lighting trunkings.
operations may have on the environment.
Besides working in a way that prevents pollution, we shall also EMC directive 89/336 EEC
ensure that, given Wibe’s production and quality requirements, the Above mentioned products are neutral according to the EMC
most environment-friendly solutions are always chosen. All of this directive 89/336 EEC.
shall be within a framework of continual improvement.
Our environmental initiatives shall go beyond what is required by Low voltage directive 73/23 EEC
legislation. According to the low voltage directive we refer to:
In its work for the environment, Wibe shall maintain suitable
dialogues and collaborations with all interested parties. SFS 1993:1068 Regulations concerning electrical material.
The environmental policy shall always be available to the public. SFS 1993:1068 General obligations regarding electrical material.
The company’s environmental reviews shall be the base on which
our environmental goals and programmes are founded. Wibe fulfils the demands according to the harmonized standard
We shall achieve the above by: SS-EN 6153 Edition 1:2002.

• Ensuring that, throughout manufacture and design, full attention is


paid to ecological considerations, quality requirements, health
factors and environmental sustainability
• Setting up environment-focused collaborations with suppliers and
customers
• Giving training on our environmental initiatives and promoting staff
involvement
• Maximising efficiency in the use of energy and raw materials
• Minimising the production of waste that cannot be recycled within
our operations
• Ensuring that chemicals and dangerous waste are handled in the
best possible manner
• Continuously evaluating the success of our initiatives

9
Product certificates

10
Product certificates

11
Potential balancing
Resistance testing of Wibe cable trays has been performed by The tests have been carried out according to SS-EN 61537,
the Swedish National Testing & Research Institute in Borås and IEC 61537 and EL-AMA SBD 2.
Wibe test laboratory.

12
Potential balancing

13
Installation
Potential summary
balancing

4
64

35 53
61 33
35
21
51

49

32
55
31
44
2 17
1
50
51

52
21
63
62

2 18,19
62 16

36 39
5
60
37
22
3

25 22
20

30
29 14
42

28 41
26
7
25
59
40
28
47
23,24

9 45

32

14
Potential balancing
Components 1Page
54
1 Cable tray W1/40 18
34 46 2 Cable tray W3/40 20-21
5 Cable tray system W1/60, W3/60 46-66
3 Mesh trays – Wibe Defem system
56 4 Installation tray W4 (system) 73-79
5 Internal cantilever arm W17/40 22
7 45
6 Adjustable cantilever arm W1840 23
7 Support bracket/joint W7/40 24
11 8 Support bracket W1940 25
9 Side joint W49/40 26
10 T-joint W9/40 27
12
8 11 T-joint W29/40 28
12 End cover W45/40 29
13 Adjustable bend W10/40 30
43 14 Vertical riser W11/40 31
15 90° bend W10/40 32-33
16 T-junction W12/40 34-35
17 X-junction W13/40 36-37
13 18 Reducing piece W14/40 left 38-39
48 19 Reducing piece W14/40 right 40-41
20 Reducing piece W15/40 straight 42-43
21 Junction box plate W24/40 44
22 Luminaire bracket W25/40 45
23 Lighting trunking W70 68
46 24 Lighting trunking W71 69
25 Support bracket W20 70
6 26 Support bracket W20A 70
27 Pendant brackets W80 and W81 71
45 28 Luminaire bracket W35 71
29 Luminaire bracket W55 72
1 30 Luminaire bracket W56 72
31 Cantilever arm 50 80
15 32 Cantilever arm 80 82
33 Wall bracket 80 83
34 Back plate W30 83
35 Mounting rail WMS25 84
38 36 Threaded rod M8 W76 85
7 37 Threaded rod M10 W76 85
38 Pendant attachment W21 86
10 39 Tube pendant attachment W73 87
40 Pendant/Fixing rail 7L, 7 88
58 41 Ceiling bracket 7 88
57 42 Vertical piece 7L, 7 89-90
43 Pendant bar 1 95
44 Pendant strip W33 96
45 Pendant rail W32 97
14 46 Ceiling attachment W31 98
47 Locking clamp W77 98
48 Vertical piece 2F 102
49 Angle bracket W8 105
50 Fixing tray N for casting-in 107
51 Earth clamp W79 109
27 52 Cover plate W16 110
53 Dividing strip 39 111
54 Insert piece W39 112
55 Support band W6 112
56 Tele-conduit 36 113
27 57 Cover W5 114
58 Cover clamp W62 115
59 Strip fixing W44 117
60 Luminaire bracket W50 118
Screw sets 119-123
3 Fixing system 124-140
61 Fixings - Ogebe 141-145
Integrated ceilings 146-168
62 Sound baffles and accessories 155-158
63 Profile W-swing 160-167
64 Wall tray W60/40 and W60/60 168
15
Common balancing
Potential parts, suspension components

31
20

20
38
20
20
20

30

18

18
18
18
18

13
12 33
26
11
9
10
8
32 28

25
31
20

31
20
20

30
18 25
29

18 30
18 35
36
20 19

19

20

14

3, (7)

4, (6)

16
Potential balancing
Components 1Page
1 Internal cantilever arm W17/40 22
2 Adjustable cantilever arm W1840 23
3 Support bracket/joint W7/40 24
4 Support bracket W1940 25
5 Adjustable cantilever arm W1860 48
6 Support bracket W1960 49
7 Support bracket/joint W7/60 50
8 Support bracket W20-70 70
9 Support bracket W20-100 70
10 Support bracket W20A-70 70
11 Support bracket W20A-100 70
12 Pendant bracket W80 71
13 Pendant bracket W81 71
14 Cantilever arm 50 80
15 Cantilever arm 80 82
16 Wall bracket 80 83
17 Back plate W30 83
18 Threaded rod W76 85
19 Pendant attachment W21 86
20 Tube pendant attachment W73 87
21 Pendant/Fixing rail 7L,7 88
22 Ceiling bracket 7 88
34 23 Vertical piece 7L, 7 89-90
21 24 End plug 7 90
22
23 25 Pendant/Fixing rail 24/34 91
26 Ceiling bracket 5 93
27 Bracket 60/40 94
27 28 Pendant bar 1 95
29 Pendant strip W33 96
38 30 Pendant rail W32 97
31 Ceiling attachment W31 98
32 Vertical piece 2 101
33 Vertical piece 2F 102
25 34 Vertical piece 20 103
35 Angle bracket W8 105
36 Angle bracket W8S 106
37 Screw sets 119-123
Fixing system 124-140
16
17
24

15
2, (5)
1

17
Potential
Cable traybalancing
W1/40, unperforated
WEF-0001
Side height 40 mm, length 2000 and 3000 mm. Secondary trays 1300-1800 mm.
Holes Ø5,8 mm at the tray ends can be used for locking of joints.

A L Plate thickness Pre-galv. Pre-galv. White30 Weight kg


mm mm mm Part.No. C* Part.No. C* 100 m
Cable tray W1/40-70 70 2000 0.7 713251 5 728986 8 95
Cable tray W1/40-100 100 2000 0.7 713252 2 728987 5 115
Cable tray W1/40-200 200 2000 0.7 713254 6 728988 2 170
Cable tray W1/40-300 300 2000 1.25 713256 0 728989 9 400
Cable tray W1/40-400 400 2000 1.25 713257 7 728990 5 500
Cable tray W1/40-500 500 2000 1.5 713258 4 728991 2 710
Cable tray W1/40-600 600 2000 1.5 723219 2 728992 9 825
Cable tray W1/40-500 FS 500 2000 1.5 786831 5 786833 9 715
Cable tray W1/40-600 FS 600 2000 1.5 786832 2 786834 6 830
Secondary W1/40-200 200 1300 0.7 737504 2 170
Secondary W1/40-200 200 1600 0.7 737505 9 170
Secondary W1/40-200 200 1800 0.7 737506 6 170
Cable tray W1/40-70 70 3000 0.7 720822 7 781334 6 95
Cable tray W1/40-100 100 3000 0.7 720984 2 781335 3 115
Cable tray W1/40-200 200 3000 0.7 720985 9 781336 0 170
Cable tray W1/40-300 300 3000 1.25 726664 7 781337 7 400
Cable tray W1/40-400 400 3000 1.25 726665 4 781338 4 500
Cable tray W1/40-500 500 3000 1.5 726666 1 781339 1 710
Cable tray W1/40-600 600 3000 1.5 726667 8 781340 7 825
*EAN-code=732167+Part.no+C (control figure)

Use and installation

Cable tray W1/40 is joined with For trays 300 mm and wider we
2 Side joints W49/40 or Support recommend to use Support
bracket/joint W7/40. bracket/joint W7/40.

18
Cable tray W1/40, unperforated
Loadings WEF-0001
In order to calculate the total deflection in the middle of the tray:
add up transversal deflection + longitudinal deflection + deflection of unloaded tray.

Transversal deflection Longitudinal deflection

Deflection of unloaded tray


Tray, length 2 m W1/40-100-200 W1/40-300-400 W1/40-500-600
Transversal deflection at 0 kg 0 mm 3 mm 5 mm
Longitudinal deflection at 0 kg 5 mm 5 mm 6 mm

19
Cable tray W3/40, perforated
WEF-0001
Pre-galvanized
Side height 40 mm, length 3000 mm.
Holes Ø5.8 at the tray ends can be used for locking of joints.
Oval holes along the tray sides can be used for mounting of accessories.

Plate Pre-galv.
A L thickness Pre-galv. White30 Weight kg
mm mm mm Part. No. C* Part. No. C* 100 m
Cable tray W3/40-50 50 3000 1.0 735388 0 737537 0 103
Cable tray W3/40-70 70 3000 1.0 735389 7 737538 7 120
Cable tray W3/40-100 100 3000 1.0 735390 3 737539 4 136
Cable tray W3/40-150 150 3000 1.0 735391 0 737540 0 170
Cable tray W3/40-200 200 3000 1.0 735392 7 737541 7 196
Cable tray W3/40-300 300 3000 1.25 735393 4 737542 4 316
Cable tray W3/40-400 400 3000 1.25 735394 1 737543 1 390
Cable tray W3/40-500 500 3000 1.5 735395 8 737544 8 590
Cable tray W3/40-600 600 3000 1.5 735396 5 737545 5 683
*EAN-code=732167+Part.no+C (control figure)
Use and installation

Cable tray W3/40 is joined with For trays 300 mm and wider we
2 Side joints W49/40 or Support recommend to use Support
bracket/joint W7/40. bracket/joint W7/40.

20
Cable tray W3/40, perforated
WEF-0001
Hot dip galvanized
Side height 40 mm, length 3000 mm.
Holes Ø5.8 at the tray ends can be used for locking of joints.
Oval holes along the tray sides can be used for mounting of accessories.

Plate ZINKPOX®
A L thickness Hot dip galv. White80 Weight kg
mm mm mm Part. No. C* Part.No. C* 100 m
Cable tray W3/40-50 50 3000 1.0 735400 9 735412 2 110
Cable tray W3/40-70 70 3000 1.0 735401 6 735413 9 120
Cable tray W3/40-100 100 3000 1.0 735402 3 735414 6 156
Cable tray W3/40-150 150 3000 1.0 735403 0 735415 3 170
Cable tray W3/40-200 200 3000 1.0 735404 7 735416 0 220
Cable tray W3/40-300 300 3000 1.25 735405 4 735417 7 350
Cable tray W3/40-400 400 3000 1.25 735406 1 735418 4 453
Cable tray W3/40-500 500 3000 1.5 735407 8 735419 1 620
Cable tray W3/40-600 600 3000 1.5 735408 5 735420 7 723
*EAN-code=732167+Part.no+C (control figure)
Use and installation

Cable tray W3/40 is joined with For trays 300 mm and wider we
2 Side joints W49/40 or Support recommend to use Support
bracket/joint W7/40. bracket/joint W7/40

21
Internal cantilever arm W17/40
WEF-0001
For mounting inside Cable trays W1/40 and W3/40.

Internal Pre-galv. ZINKPOX®


cantilever arm A B C D E Pre-galv. Hot dip Galv. White30 White80 Weight kg
mm mm mm mm mm Part. No. C* Part. No. C* Part. No. C* Part. No. C* 100 pcs
W17/40-100 89 140 70 55 42 716911 5 734572 4 729029 1 783066 4 16
W17/40-200 189 140 70 55 42 716912 2 734573 1 729030 7 783067 1 35
W17/40-300 289 165 95 75 55 716913 9 734574 8 729031 4 783068 8 80
W17/40-400 389 165 95 75 55 716914 6 734575 5 729032 1 783069 5 100
*EAN-code=732167+Part.no+C (control figure)
Loading table for Internal cantilever arm W17/40 on wall

Mounted onto wall with Expansion


bolt.
Breaking load for cantilever arm
mounted onto wall, see below.

Type of Max load F at 3˚ deflection Deflection in mm at 3˚ deflection Breaking load


cantilever arm of cantilever arm of cantilever arm
kN kg kN kg
W17/40-100 1.0 100 5.2 3.0 300
W17/40-200 0.8 80 10.5 2.0 200
W17/40-300 1.1 110 15.7 3.0 300
W17/40-400 1.0 100 20.9 2.0 200
Use and installation

Internal cantilever arm W17/40 is When mounting an Internal canti- The Internal cantilever arm is Internal cantilever arm W17/40
mounted on Vertical piece 2F lever arm W17/40 on a porous mounted onto the wall with an can be mounted right over
using a T-bolt. wall or when surface pressure Expansion bolt alt. a Concrete support bracket/joint.
must be reduced use Mounting screw.
rail 40.
22
Adjustable cantilever arm W1840
For installation inside Cable trays W1/40 and W3/40. WEF-0001

Adjustable Pre-galv. ZINKPOX®


cantilever arm A B C D Pre-galv. Hot dip galv. White30 White80 Weight kg
mm mm mm mm Part. No. C* Part. No. C* Part. No. C* Part. No. C* 100 pcs
W1840-100 88 160 70 0-25 718360 9 734578 6 729033 8 783018 3 36
W1840-200 188 160 70 0-50 718361 6 734579 3 729034 5 783019 0 47
W1840-300 289 185 95 0-50 783587 4 734580 9 783591 1 783020 6 120
W1840-400 389 185 95 0-50 783588 1 734581 6 783592 8 783021 3 139
W1840-500 489 185 95 0-50 783589 8 734582 3 783593 5 783022 0 156
W1840-600 589 185 95 0-50 783590 4 734583 0 783594 2 783023 7 175
*EAN-code=732167+Part.no+C (control figure)
Loading table for cantilever arm W1840 on wall

Mounted onto wall with Expansion bolt.


Breaking load for cantilever arm
mounted onto wall - see below.

Type of Max load F at 3˚ deflection Deflection in mm at 3˚ deflection Breaking load


cantilever arm of cantilever arm of cantilever arm
kN kg kN kg
W1840-100 1.0 100 5.2 3.0 300
W1840-200 0.8 80 10.5 2.0 200
W1840-300 1.1 110 15.7 3.0 300
W1840-400 1.0 100 20.9 2.0 200
W1840-500 0.65 65 26 1.3 130
W1840-600 0.5 50 31.5 1.0 100
Use and installation

Mounting directly onto wall. Mounting on Vertical piece 2F Mounting of two adjustable canti- When mounting cable trays -
At this type of installation the using T-bolt. The Cantilever arm lever arms on the same Vertical width 500-600 mm - it might be
adjusting allowance of the tray is W1840 can be adjusted to a piece 2F. (Tray widths more than necessary with a reinforcement
limited. max. of 50 mm. 400 mm). of the cantilever arm. Installation
Breaking load - see table above. Use Screw set 20S if the two band and stretching screw can
trays have the same width. be used for mounting in ceiling or
At different tray widths T -bolt on a vertical piece.
and Screw set W37 must be
used.

23
Support bracket/joint W7/40
Used as a support bracket or joint for Cable tray W1/40 and W3/40 and for Lighting trunking W70/W71. WEF-0001
When joining Cable tray W1/40 FS (reinforced), Side joint W49/40 must be used.

W7/40-70,100,200,300,400 W7/40-50,150,500,600

W7/40-40

Support bracket/ Plate Pre-galv. ZINKPOX®


joint A B thickness Pre-galv Hot dip galv. White30 White80 Weight kg
mm mm mm Part. No. C* Part. No. C* Part. No. C* Part. No. C* 100 pcs
W7/40-40 36 180 1.5 718480 4 729053 6 12
W7/40-50 48 200 1.0 734554 0 734556 4 783080 0 14
W7/40-70 68 200 1.0 720825 8 734557 1 729046 8 783081 7 16
W7/40-100 98 200 1.0 717021 0 734558 8 729047 5 783082 4 25
W7/40-150 148 200 1.0 734555 7 734559 5 783083 1 35
W7/40-200 198 200 1.0 717022 7 734560 1 729048 2 783084 8 43
W7/40-300 297 300 1.25 717023 4 734561 8 729049 9 783085 5 110
W7/40-400 397 300 1.25 717024 1 734562 5 729050 5 783086 2 140
W7/40-500 498 300 1.25 720990 3 734563 2 729051 2 783087 9 170
W7/40-600 598 300 1.25 723180 5 734564 9 729052 9 783088 6 200
*EAN-code=732167+Part.no+C (control figure)
Use and installation

Support bracket/joint W7/40 is If necessary trays and lighting With Pendant attachment W21 Tube pendant attachment W73
used for straight joining. Push-in trunkings are locked using Screw installed on Support bracket/joint or the one half of Pendant
mounting. set W38P or Locking plug W41. W7/40-100, 200, 300 or 400 a attachment W21 are mounted
The Joint W7/40-40 is locked complete support bracket is on
with Screw set W36/W36C at the obtained. Support bracket/joint W7/40-70,
bottom of the trunking. 100, 200, 300 or 400 with Screw
set W36/W36C.

W7/40-50, 150, 500 and 600 are End bracket WN17 can be used Support bracket/joint W7/40 is
only used for joining, not as sup- as vertical piece on Support used to achieve an invisible
port brackets. bracket/joint W7/40 mounted suspension in or in connection
Reinforced tray is to be joined with Screw set W36/W36C. with bends or junctions, here with
with Side joint W49/40. End bracket WN17 mounted as
vertical piece.
24
Support bracket W1940
WEF-0001
For installation inside Cable trays W1/40 and W3/40.

Support bracket Pre-galv. ZINKPOX®


A Pre-galv. Hot dip galv. White30 White80 Weight kg
mm Part. No. C* Part. No. C* Part. No. C* Part. No. C* 100 pcs
W1940-100 90 718711 9 734452 9 729041 3 783060 2 11
W1940-200 190 734401 7 734453 6 729042 0 783061 9 22
W1940-300 289 734402 4 734454 3 729043 7 783062 6 50
W1940-400 389 734403 1 734455 0 729044 4 783063 3 68
W1940-500 489 782342 0 734456 7 783753 3 783064 0 91
W1940-600 589 782343 7 734457 4 783754 0 783065 7 110
*EAN-code=732167+Part.no+C (control figure)

Use and installation

Tray W1/40 and W3/40 with Support bracket W1940 mounted Support bracket W1940 mounted Support bracket W1940 can be
widths of 200 to 400 are with Ceiling bracket 5, Pendant/ on Vertical piece 2 and Ceiling mounted with Vertical piece 2,
mounted with suitable Support Fixing rail 24/34 and Angle bracket 5. Screw set 22S must Pendant joint 2J, Pendant/Fixing
bracket W1940, Pendant rail bracket W8S. Screw set 22S be used. For cable trays with rail 24/34 and Ceiling bracket 5.
W32, Pendant attachment must be used. For cable trays width 500 och 600. Screw set 22S must be used.
W21, Screw sets W37 and W36/ with width 500 and 600. For cable trays with width 500
W36C. and 600.
Trays with width 100 can be
mounted with Support bracket
W1940-100, one half of Pendant
attachment W21 or Tube
pendant W73 and Screw set
W36/W36C.

Alternatively, Tray W1/40 and Alternatively, Tray W1/40 and Alternatively, Tray W1/40 and Tray W1/40 and W3/40 can be
W3/40 with widths 500 and 600 W3/40 with widths 500 and 600 W3/40 with widths 500 and 600 mounted on suitable Support
can be installed with suitable can be installed with suitable can be installed with suitable bracket W1940 and 2 End
Support bracket W1940, Support bracket W1940, Support bracket W1940, bracket WN17 as pendant.
Threaded rod M10 W76 and Threaded rod M10 W76 and Pendant rail W32, Pendant The end brackets are joined with
2 M10 nuts. Tube pendant attachment W73. attachment W21 and Screw set 2 Screw sets 22S and can be
W37. adjusted in height. The pendant
can be mounted in the support
bracket with Screw set W36/
W36C.

25
Side joint W49/40
WEF-0001
For straight joining of Cable tray W1/40 and W3/40.

Pre-galv. ZINKPOX®
Pre-galv. Hot dip galv. White30 White80 Weight kg
Part. No. C* Part. No. C* Part. No. C* Part. No. C* 100 pcs
Side joint W49/40 786837 7 730191 1 786838 4 790231 6** 17
*EAN-code=732167+Part.no+C (control figure) **Produced to order
Use and installation

2 Side joints W49/40 are used


for straight joining of Cable tray
W1/40, W1/40 FS and W3/40.
4 Screw sets W38P are required
(not included).
For trays 300 mm and wider we
recommend to use Support
bracket/joint W7/40.

Reducer W28/40
WEF-0001
Used for transition joining from a wider to a narrower cable tray.

Pre-galv.
A B Pre-galv. White30 Weight kg
mm mm Part. No. C* Part. No. C* 100 pcs
Reducer W28/40-100 100 37.5 787436 1 787438 5 17
Reducer W28/40-200 200 37.5 787437 8 787439 2 23
*EAN-code=732167+Part.no+ (control figure)
Use and installation

Used together with 1 Side joint


W49/40 at one-side transition 2 Reducers W28/40 are used at
joining of Cable tray W1/40 and centered transition joining, to be
W3/40, to be mounted with 2 mounted with Screw set W38P.
Screw sets W38P. Always use Always use support close to the
support close to the reducer. reducer.

26
T-joint W9/40
WEF-0001
Mounted in T- or X-branches. Also used for oblique branches.

Part. No. includes 2 T-joints W9/40

Plate Pre-galv. ZINKPOX®


thickness Pre-galv. Hot dip galv. White30 White80 Weight kg
mm Part. No. C* Part. No. C* Part. No. C* Part. No. C* 100 pcs
T-joint W9/40 1.0 718205 3 734622 6 729094 9 783128 9 6
(Screw set W38P incl)
*EAN-code=732167+Part.no+C (control figure)

Use and installation


1

2
Potential balancing T-joint W9/40 is mounted on the Straight angling. If necessary, the Oblique angling. If necessary, the
In order to fulfil the potential side edges of the tray with Screw lugs are locked to the edge of the lugs are locked to the edge of the
balancing according to SS-EN set W38P. tray using pliers. Can also be tray using pliers. Can also be
61537 the T-joint must be locked with blind rivets or self- locked with blind rivets or self-
secured with tapping screws. tapping screws.
1 Self-drilling screw
RXB 4.2 x 13
2 Screw set W38P,
drilling is required.
Tightening torque 2 Nm.

27
T-joint W29/40
WEF-0001
Simple push-in assembly.
Is hung over the edge of the tray and locked in a suitable way.

Pre-galv.
A B Pre-galv. White 30 Weight kg
mm mm Part. No. C* Part. No. C* 100 pcs
T-joint W29/40-70 68 - 790984 1 724942 8 8
T-joint W29/40-100 98 - 790985 8 724943 5 12
T-joint W29/40-200 198 120 790986 5 724944 2 21
T-joint W29/40-300 301 220 790987 2 724945 9 30
T-joint W29/40-400 401 320 790988 9 724946 6 40
T-joint W29/40-500 501 420 790989 6 724947 3 50
T-joint W29/40-600 601 520 790990 2 724948 0 59
*EAN-code=732167+Part.no+C (control figure)

Use and installation

Potential balancing Simply installed with push-in Used with T- and X-junction. Used with open junction together
In order to fulfil the potential mounting. Lock into tray with Mounted directly onto tray edge. with Joint W7/40 with opening
balancing according to SS-EN Screw set W38P. Can be attached to tray by and Tray W1/40 with opening.
61537 the T-joint must be pinching the lip at the top of the Attached with Screw set W38P.
secured with tray.
1 Self-drilling screw
RXB 4.2 x 13
2 Screw set W38P,
Tightening torque 2 Nm.

Examples of suspensions with open junction where T-joint W29/40, Tray W1/40 with opening and Joint W7/40 with opening are included.

Suspension with Pendant strip Suspension with Pendant rail Suspension with End bracket Suspension with wire and Ogebe
W33. W32 and half a Pendant attach- WN17. fixing type E.
ment W21.

28
End cover W45/40
WEF-0001
For push-in assembly. Mounted as end cover in Cable trays W1/40 and W3/40 and lighting trunking.

Pre-galv. ZINKPOX®
A Pre-galv. Hot dip galv. White30 White80 Weight kg
mm Part. No. C* Part. No. C* Part. No. C* Part. No. C* 100 pcs
End cover W45/40-70 68 731730 1 783030 5 729177 9 783000 8 8
End cover W45/40-100 98 731731 8 783031 2 729178 6 783001 5 9
End cover W45/40-150 148 783032 9 783002 2 10
End cover W45/40-200 198 731732 5 783033 6 729179 3 783003 9 12
End cover W45/40-300 298 731733 2 783034 3 729180 9 783004 6 15
End cover W45/40-400 398 731734 9 783035 0 729181 6 783005 3 18
End cover W45/40-500 498 731735 5 783036 7 729182 3 783006 0 21
End cover W45/40-600 598 731736 1 783037 4 729183 0 783007 7 24
*EAN-code=732167+Part.no+C (control figure)

Use and installation

Mounted as end in trays and


lighting trunking. Locked with
Locking plug W41 or Screw set
W38P.

29
Adjustable bend W10/40
WEF-0001
Adjustable bend W10/40 permits horizontal angling from 105º to 165º in steps of 7.5º.
Push-in installation.

Plate Pre-galv. ZINKPOX®


A thickness Pre-galv. Hot dip galv. White30 White80 Weight kg
mm mm Part. No. C* Part. No. C* Part. No. C* Part. No. C* 100 pcs
Adjustable bend W10/40-50 47 1.0 734584 7 734591 5 782850 0 9
Adjustable bend W10/40-70 67 1.0 716833 0 734592 2 729103 8 782851 7 10
Adjustable bend W10/40-100 97 1.0 716834 7 734593 9 729104 5 782852 4 13
Adjustable bend W10/40-150 147 1.0 734585 4 734594 6 782853 1 24
Adjustable bend W10/40-200 197 1.0 716835 4 734595 3 729105 2 782854 8 40
Adjustable bend W10/40-300 297 1.0 716836 1 734596 0 729106 9 782855 5 75
Adjustable bend W10/40-400 397 1.0 716837 8 734597 7 729107 6 782856 2 125
Adjustable bend W10/40-500 497 1.25 724965 7 734598 4 729108 3 782857 9 270
Adjustable bendW10/40-600 597 1.25 724966 4 734599 1 729109 0 782858 6 380
*EAN-code=732167+Part.no+C (control figure)

Use and installation

Push-in installation. Turn up Adjustable bend W10/40 permits If necessary, Adjustable bend
inner and outer sides and mount desired horizontal angling W10/40 may be locked using
the Adjustable bend W10/40 between 105º and 165º in stages Screw set W38P or Locking plug
inside the tray. of 7.5º. W41.

30
Vertical riser W11/40
WEF-0001
For upward or downward angling to a desired angle up to 90˚, push-in assembly.
Should be locked with Screw set W38P or Locking plug W41.

Vertical riser Plate Pre-galv. ZINKPOX®


A L thickness Pre-galv. Hot dip galv. White30 White80 Weight kg
mm mm mm Part. No. C* Part. No. C* Part. No. C* Part. No. C* 100 pcs
W11/40-50 48 150 0.7 733498 8 734101 1 783040 4 8
W11/40-70 68 150 0.7 723226 0 734102 3 729126 7 783041 1 10
W11/40-100 98 150 0.7 723227 7 734103 0 729127 4 783042 8 12
W11/40-150 148 150 0.7 733499 5 734104 7 783043 5 17
W11/40-200 198 200 0.7 723228 4 734105 4 729128 1 783044 2 28
W11/40-300 298 200 0.7 723229 1 734106 1 729129 8 783045 9 39
W11/40-400 398 200 0.7 723230 7 734107 8 729130 4 783046 6 50
W11/40-500 498 200 0.7 723231 4 734108 5 729131 1 783047 3 61
W11/40-600 598 200 0.7 723232 1 734109 2 729132 8 783048 0 73
*EAN-code=732167+Part.no+C (control figure)

Use and installation

For upward or downward angling at a desired angle up to 90˚. Should be attached with Screw set W38P or Locking plug W41.
Push-in installation.

Vertical riser W11/40 is delivered


flat and must be bent by the
installer on the job site.

31
90˚ bend W10/40
WEF-0001
Pre-galvanized
For 90˚ horizontal junction of Cable trays W1/40 and W3/40.
Push-in assembly.

Plate Pre-galv.
A thickness Pre-galv. White30 Weight kg
mm mm Part. No. C* Part. No. C* 100 pcs
90˚ bend W10/40-70 67 1.25 717903 9 729201 1 38
90˚ bend W10/40-100 97 1.25 717904 6 729133 5 51
90˚ bend W10/40-200 197 1.25 717905 3 729134 2 108
90˚ bend W10/40-300 297 1.25 717906 0 729135 9 185
90˚ bend W10/40-400 397 1.25 717907 7 729136 6 281
90˚ bend W10/40-500 497 1.25 721184 5 729137 3 400
90˚ bend W10/40-600 597 1.25 723196 6 729138 0 540
*EAN-code=732167+Part.no+C (control figure)

Use and installation

Used for 90˚ horizontal angling. If necessary, the 90˚ bend W10/ Support bracket/joint W7/40, with
Suspension components should 40 can be locked using Screw a suitable pendant, is used to
be mounted in or in connection set W38P or Locking plug W41. achieve an invisible suspension,
with the junction. Can be provided with holes in here with End bracket WN17
Push-in installation. bottom for suspension in mounted as vertical piece.
Pendant attachment W21 alt.
W73.
Valid for max. width 200 mm.

32
90˚ bend W10F/40
WEF-0001
Hot dip galvanized
For 90˚ horizontal junction of Cable trays W1/40 and W3/40.
Push-in assembly.

Plate ZINKPOX®
A L thickness Hot dip galv. White80 Weight kg
mm mm mm Part. No. C* Part. No. C* 100 pcs
90˚ bend W10F/40-50 47 119 1.25 783660 4 783600 0 18
90˚ bend W10F/40-70 67 153 1.25 783661 1 783601 7 28
90˚ bend W10F/40-100 97 204 1.25 783662 8 783602 4 48
90˚ bend W10F/40-150 147 290 1.25 783663 5 783603 1 92
90˚ bend W10F/40-200 197 375 1.25 783664 2 783604 8 148
90˚ bend W10F/40-300 297 480 1.25 783665 9 783605 5 242
90˚ bend W10F/40-400 397 580 1.25 783666 6 783606 2 353
90˚ bend W10F/40-500 497 714 1.25 783667 3 783607 9 528
90˚ bend W10F/40-600 597 814 1.25 783668 0 783608 6 685
*EAN-code=732167+Part.no+C (control figure)
Use and installation

Used for 90˚ horizontal angling.


Suspension components should
be mounted in or in connection
with the junction.
Push-in installation.

33
T-junction W12/40
WEF-0001
Pre-galvanized
For 90˚ horizontal junction of Cable trays W1/40 and W3/40.
Push-in assembly.

Plate Pre-galv.
A thickness Pre-galv. White30 Weight kg
mm mm Part. No. C* Part. No. C* 100 pcs
T-junction W12/40-70 67 1.25 717908 4 729139 7 49
T-junction W12/40-100 97 1.25 717909 1 729140 3 64
T-junction W12/40-200 197 1.25 717910 7 729141 0 128
T-junction W12/40-300 297 1.25 717911 4 729142 7 212
T-junction W12/40-400 397 1.25 717912 1 729143 4 314
T-junction W12/40-500 497 1.25 721186 9 729144 1 438
T-junction W12/40-600 597 1.25 723198 0 729145 8 580
*EAN-code=732167+Part.no+C (control figure)

Use and installation

Used for horizontal 90˚ junction. Suspension components should be If necessary, the T-junction W12/40 can be locked using Screw set
mounted in or in connection with the junction. Push-in installation. W38P or Locking plug W41.
Can be provided with holes in bottom for suspension in Pendant
attachment W21 or Tube pendant attachment W73. Valid for max.
width 200 mm.

Support bracket/joint W7/40, with


a suitable pendant, is used to
achieve an invisible suspension,
here with End bracket WN17
mounted as vertical piece.

34
T-junction W12F/40
WEF-0001
Hot dip galvanized
For 90˚ horizontal junction of Cable trays W1/40 and W3/40.
Push-in assembly.

Plate ZINKPOX®
A L thickness Hot dip galv. White80 Weight kg
mm mm mm Part. No. C* Part. No. C* 100 pcs
T-junction W12F/40-50 47 171 1.25 783670 3 783620 8 26
T-junction W12F/40-70 67 219 1.25 783671 0 783621 5 35
T-junction W12F/40-100 97 312 1.25 783672 7 783622 2 60
T-junction W12F/40-150 147 432 1.25 783673 4 783623 9 110
T-junction W12F/40-200 197 553 1.25 783674 1 783624 6 192
T-junction W12F/40-300 297 662 1.25 783675 8 783625 3 300
T-junction W12F/40-400 397 762 1.25 783676 5 783626 0 428
T-junction W12F/40-500 497 932 1.25 783677 2 783627 7 640
T-junction W12F/40-600 597 1032 1.25 783678 9 783628 4 817
*EAN-code=732167+Part.no+C (control figure)

Use and installation

Used for horizontal 90˚ junction.


Suspension components should
be mounted in or in connection
with the junction.
Push-in installation.

35
X-junction W13/40
WEF-0001
Pre-galvanized
For 90˚ horizontal junction of Cable trays W1/40 and W3/40.
Push-in assembly.

Plate Pre-galv.
A thickness Pre-galv. White30 Weight kg
mm mm Part. No. C* Part. No. C* 100 pcs
X-junction W13/40-70 67 1.25 717913 8 729146 5 64
X-junction W13/40-100 97 1.25 717914 5 729147 2 80
X-junction W13/40-200 197 1.25 717915 2 729148 9 150
X-junction W13/40-300 297 1.25 717916 9 729149 6 240
X-junction W13/40-400 397 1.25 717917 6 729150 2 350
X-junction W13/40-500 497 1.25 721188 3 729151 9 480
X-junction W13/40-600 597 1.25 723200 0 729152 6 630
*EAN-code=732167+Part.no+C (control figure)

Use and installation

Used for horizontal 90˚ junction of four trays with the same width. If necessary, the X-junction W13/40 can be locked using Screw set
Suspension components should be mounted in or in connection with W38P or Locking plug W41. Can be provided with holes in bottom for
the junction. suspension in Pendant attachment W21 or Tube pendant attachment
Push-in installation. W73. Valid for max. width 200 mm.

Support bracket/joint W7/40, with


a suitable pendant, is used to
achieve an invisible suspension,
here with End bracket WN17
mounted as vertical piece.

36
X-junction W13F/40
WEF-0001
Hot dip galvanized
For 90˚ horizontal junction of Cable trays W1/40 and W3/40.
Push-in assembly.

Plate ZINKPOX®
A L thickness Hot dip galv. White80 Weight kg
mm mm mm Part. No. C* Part. No. C* 100 pcs
X-junction W13F/40-50 47 148 1.25 783680 2 783640 6 27
X-junction W13F/40-70 67 217 1.25 783681 9 783641 3 43
X-junction W13F/40-100 97 313 1.25 783682 6 783642 0 74
X-junction W13F/40-150 147 434 1.25 783683 3 783643 7 147
X-junction W13F/40-200 197 555 1.25 783684 0 783644 4 243
X-junction W13F/40-300 297 662 1.25 783685 7 783645 1 370
X-junction W13F/40-400 397 762 1.25 783686 4 783646 8 510
X-junction W13F/40-500 497 932 1.25 783687 1 783647 5 766
X-junction W13F/40-600 597 1032 1.25 783688 8 783648 2 966
*EAN-code=732167+Part.no+C (control figure)

Use and installation

Used for horizontal 90˚ junction


of four trays with the same width.
Suspension components should
be mounted in or in connection
with the junction.
Push-in installation.

37
Reducing piece W14/40 left
WEF-0001
Pre-galvanized
For push-in assembly. Fitted for transition between different widths of Cable trays W1/40 and W3/40 at wall mountings.

Plate Pre-galv.
A B thickness Pre-galv. White30 Weight kg
mm mm mm Part. No. C* Part. No. C* 100 pcs
Reducing piece W14/40 200-100 left 198 98 1.0 713620 9 729159 5 53
Reducing piece W14/40 300-100 left 298 98 1.25 713622 3 729160 1 81
Reducing piece W14/40 400-100 left 398 98 1.25 713623 0 729161 8 96
Reducing piece W14/40 300-200 left 298 198 1.25 713631 5 729162 5 96
Reducing piece W14/40 400-200 left 398 198 1.25 713632 2 729163 2 111
Reducing piece W14/40 400-300 left 398 298 1.25 713637 7 729164 9 126
*EAN-code=732167+Part.no+C (control figure)

Use and installation

For transition between different If necessary, the Reducing piece Suspension components should
widths of trays and rails during W14/40 can be locked using be mounted in or in connection
wall mounting. Screw set W38P or Locking plug with the reducing piece.
Push-in installation. W41. Support bracket/joint W7/40 and
a suitable pendant can be used to
achieve an invisible suspension,
here with End bracket WN17
mounted as vertical piece.

38
Reducing piece W14/40 left
WEF-0001
Hot dip galvanized
For push-in assembly. Fitted for transition between different widths of Cable trays W1/40 and W3/40 at wall mountings.

E
WIBE
C

Plate ZINKPOX®
A B L thickness Hot dip galv. White80 Weight kg
mm mm mm mm Part. No. C* Part. No. C* 100 pcs
Reducing piece W14/40 150-100 left 147 97 132 1.25 787796 6 787811 6 23
Reducing piece W14/40 200-100 left 197 97 182 1.0 783696 3 783708 3 38
Reducing piece W14/40 200-150 left 197 147 132 1.25 787797 3 787812 3 30
Reducing piece W14/40 300-100 left 297 97 282 1.25 783697 0 783709 0 75
Reducing piece W14/40 300-150 left 297 147 222 1.25 787798 0 787813 0 67
Reducing piece W14/40 300-200 left 297 197 182 1.25 783699 4 783711 3 56
Reducing piece W14/40 400-100 left 397 97 382 1.25 783698 7 783710 6 121
Reducing piece W14/40 400-150 left 397 147 332 1.25 787799 7 787814 7 113
Reducing piece W14/40 400-200 left 397 197 282 1.25 783700 7 783712 0 102
Reducing piece W14/40 400-300 left 397 297 182 1.25 783701 4 783713 7 74
Reducing piece W14/40 500-100 left 497 97 482 1.25 787785 0 787800 0 178
Reducing piece W14/40 500-150 left 497 147 432 1.25 787786 7 787801 7 170
Reducing piece W14/40 500-200 left 497 197 382 1.25 787787 4 787802 4 159
Reducing piece W14/40 500-300 left 497 297 282 1.25 787788 1 787803 1 130
Reducing piece W14/40 500-400 left 497 397 182 1.25 787789 8 787804 8 92
Reducing piece W14/40 600-100 left 597 97 582 1.25 787790 4 787805 5 245
Reducing piece W14/40 600-150 left 597 147 532 1.25 787791 1 787806 2 236
Reducing piece W14/40 600-200 left 597 197 482 1.25 787792 8 787807 9 226
Reducing piece W14/40 600-300 left 597 297 382 1.25 787793 5 787808 6 197
Reducing piece W14/40 600-400 left 597 397 282 1.25 787794 2 787809 3 158
Reducing piece W14/40 600-500 left 597 497 182 1.25 787795 9 787810 9 101
*EAN-code=732167+Part.no+C (control figure)

Use and installation

E
WIBE
C

For transition between different


widths of trays and rails during
wall mounting.
Push-in installation.

39
Reducing piece W14/40 right
WEF-0001
Pre-galvanized
For push-in assembly. Fitted for transition between different widths of Cable trays W1/40 and W3/40 at wall mountings.

Plate Pre-galv.
A B thickness Pre-galv. White30 Weight kg
mm mm mm Part. No. C* Part. No. C* 100 pcs
Reducing piece W14/40 200-100 right 198 98 1.0 713536 3 729165 6 53
Reducing piece W14/40 300-100 right 298 98 1.25 713538 7 729166 3 81
Reducing piece W14/40 400-100 right 398 98 1.25 713539 4 729167 0 96
Reducing piece W14/40 300-200 right 298 198 1.25 713547 9 729168 7 96
Reducing piece W14/40 400-200 right 398 198 1.25 713548 6 729169 4 111
Reducing piece W14/40 400-300 right 398 298 1.25 713553 0 729170 0 126
*EAN-code=732167+Part.no+C (control figure)

Use and installation

For transition between different If necessary, the Reducing piece Suspension components should
widths of trays and rails during W14/40 can be locked using be mounted in or in connection
wall mounting. Push-in installa- Screw set W38P or locking plug with the reducing piece.
tion. W41. Support bracket/joint W7/40 and
a suitable pendant can be used to
achieve an invisible suspension,
here with End bracket WN17
mounted as vertical piece.

40
Reducing piece W14/40 right
WEF-0001
Hot dip galvanized
For push-in assembly. Fitted for transition between different widths of Cable trays W1/40 and W3/40 at wall mountings.

Plate ZINKPOX®
A B L thickness Hot dip galv. White80 Weight kg
mm mm mm mm Part. No. C* Part. No. C* 100 pcs
Reducing piece W14/40 150-100 right 147 97 132 1.25 787841 3 787856 7 23
Reducing piece W14/40 200-100 right 197 97 182 1.0 783690 1 783714 4 38
Reducing piece W14/40 200-150 right 197 147 132 1.25 787842 0 787857 4 30
Reducing piece W14/40 300-100 right 297 97 282 1.25 783691 8 783715 1 75
Reducing piece W14/40 300-150 right 297 147 222 1.25 787843 7 787858 1 67
Reducing piece W14/40 300-200 right 297 197 182 1.25 783693 2 783717 5 56
Reducing piece W14/40 400-100 right 397 97 382 1.25 783692 5 783716 8 121
Reducing piece W14/40 400-150 right 397 147 332 1.25 787844 4 787859 8 113
Reducing piece W14/40 400-200 right 397 197 282 1.25 783694 9 783718 2 102
Reducing piece W14/40 400-300 right 397 297 182 1.25 783695 6 783719 9 74
Reducing piece W14/40 500-100 right 497 97 482 1.25 787830 7 787845 1 178
Reducing piece W14/40 500-150 right 497 147 432 1.25 787831 4 787846 8 170
Reducing piece W14/40 500-200 right 497 197 382 1.25 787832 1 787847 5 159
Reducing piece W14/40 500-300 right 497 297 282 1.25 787833 8 787848 2 130
Reducing piece W14/40 500-400 right 497 397 182 1.25 787834 5 787849 9 92
Reducing piece W14/40 600-100 right 597 97 582 1.25 787835 2 787850 5 245
Reducing piece W14/40 600-150 right 597 147 532 1.25 787836 9 787851 2 236
Reducing piece W14/40 600-200 right 597 197 482 1.25 787837 6 787852 9 226
Reducing piece W14/40 600-300 right 597 297 382 1.25 787838 3 787853 6 197
Reducing piece W14/40 600-400 right 597 397 282 1.25 787839 0 787854 3 158
Reducing piece W14/40 600-500 right 597 497 182 1.25 787840 6 787855 0 101
*EAN-code=732167+Part.no+C (control figure)

Use and installation

For transition between different


widths of trays and rails during
wall mounting.
Push-in installation.

41
Reducing piece W15/40 straight
WEF-0001
Pre-galvanized
For push-in assembly.
Fitted for transition between different widths of Cable trays W1/40 and W3/40 at symmetric ceiling installation.

Plate Pre-galv.
A B thickness Pre-galv. White30 Weight kg
mm mm mm Part. No. C* Part. No. C* 100 pcs
Reducing piece W15/40 200-100 straight 198 98 1.0 713704 6 729171 7 53
Reducing piece W15/40 300-100 straight 298 98 1.25 713706 0 729172 4 81
Reducing piece W15/40 400-100 straight 398 98 1.25 713707 7 729173 1 96
Reducing piece W15/40 300-200 straight 298 198 1.25 713715 2 729174 8 96
Reducing piece W15/40 400-200 straight 398 198 1.25 713716 9 729175 5 111
Reducing piece W15/40 400-300 straight 398 298 1.25 713721 3 729176 2 126
*EAN-code=732167+Part.no+C (control figure)

Use and installation

For transition between different If necessary, the Reducing piece Suspension components should
tray widths during symmetric W15/40 can be locked using be mounted in or in connection
ceiling installation. Screw set W38P or Locking plug with the reducing piece
Push-in assembly. W41. Support bracket/joint W7/40 and a
suitable pendant can be used to
achieve an invisible suspension,
here with End bracket WN17
mounted as vertical piece.

42
Reducing piece W15/40 straight
WEF-0001
Hot dip galvanized
For push-in assembly.
Fitted for transition between different widths of Cable trays W1/40 and W3/40 at symmetric ceiling installation.

Plate ZINKPOX®
A B L thickness Hot dip galv. White80 Weight kg
mm mm mm mm Part. No. C* Part. No. C* 100 pcs
Reducing piece W15/40 150-100 straight 147 97 118 1.25 787751 5 787766 9 20
Reducing piece W15/40 200-100 straight 197 97 154 1.0 783702 1 783720 5 25
Reducing piece W15/40 200-150 straight 197 147 118 1.25 787752 2 787767 6 26
Reducing piece W15/40 300-100 straight 297 97 225 1.25 783703 8 783721 2 59
Reducing piece W15/40 300-150 straight 297 147 190 1.25 787753 9 787768 3 53
Reducing piece W15/40 300-200 straight 297 197 154 1.25 783705 2 783723 6 46
Reducing piece W15/40 400-100 straight 397 97 297 1.25 783704 5 783722 9 94
Reducing piece W15/40 400-150 straight 397 147 261 1.25 787754 6 787769 0 88
Reducing piece W15/40 400-200 straight 397 197 225 1.25 783706 9 783724 3 81
Reducing piece W15/40 400-300 straight 397 297 154 1.25 783707 6 783725 0 61
Reducing piece W15/40 500-100 straight 497 97 368 1.25 787740 9 787755 3 135
Reducing piece W15/40 500-150 straight 497 147 333 1.25 787741 6 787756 0 129
Reducing piece W15/40 500-200 straight 497 197 297 1.25 787742 3 787757 7 122
Reducing piece W15/40 500-300 straight 497 297 225 1.25 787743 0 787758 4 103
Reducing piece W15/40 500-400 straight 497 397 154 1.25 787744 7 787759 1 76
Reducing piece W15/40 600-100 straight 597 97 440 1.25 787745 4 787760 7 183
Reducing piece W15/40 600-150 straight 597 147 404 1.25 787746 1 787761 4 178
Reducing piece W15/40 600-200 straight 597 197 368 1.25 787747 8 787762 1 171
Reducing piece W15/40 600-300 straight 597 297 297 1.25 787748 5 787763 8 151
Reducing piece W15/40 600-400 straight 597 397 225 1.25 787749 2 787764 5 125
Reducing piece W15/40 600-500 straight 597 497 154 1.25 787750 8 787765 2 91
*EAN-code=732167+Part.no+C (control figure)

Use and installation

For transition between different


tray widths during symmetric
ceiling installation.
Push-in assembly.

43
Junction box plate W24/40
WEF-0001
Junction box plate W24 for installing junction boxes, light fittings etc. in Cable trays W1/40, W3/40 and lighting trunkings.

Unholed

Plate Pre-galv. ZINKPOX®


Junction box plate thickness Pre-galv. Hot dip galv. White30 White80 Weight kg
mm Part. No. C* Part. No. C* Part. No. C* Part. No. C* 100 pcs
W24/40 1.0 717995 4 734617 2 729184 7 783130 2 31
W24/40 unholed 1.0 730247 5 734211 2 31
*EAN-code=732167+Part.no+C (control figure)

Use and installation

The Junction box plate W24/40 is If necessary, the Junction box Can be mounted in the middle of To firmly attach Junction box
mounted between the bottom of plate W24/40 can be screwed Lighting trunking W70/W71-100 plate W24/40 in Tray W1/40 or
the trunking or tray and its folded tight directly in Tray W3/40 with and W70-200 with Screw set W3/40, use blind rivets, self-
seam. Screw set W38P. If one requires W36 or Tray W3/40 with Screw tapping screws or Screw set
a hidden socket box, the junction set W38P. W38P.
box should be folded inwards.

44
Luminaire bracket W25/40
WEF-0001
Used for assembly of light fittings under Cable trays W1/40 and W3/40 or Lighting trunking W70/W71.

Plate Pre-galv.
A thickness Pre-galv. White30 Weight kg
mm mm Part. No. C* Part. No. C* 100 pcs
Luminaire bracket W25/40-70 72 1.25 713911 8 729185 4 7
Luminaire bracket W25/40-100 101 1.25 713912 5 729186 1 8
Luminaire bracket W25/40-200 201 1.25 713914 9 729187 8 11
Luminaire bracket W25/40-300 301 1.25 713916 3 729188 5 19
Luminaire bracket W25/40-400 401 1.25 713917 0 729189 2 23
Luminaire bracket W25/40-500 501 1.25 713918 7 729190 8 27
Luminaire bracket W25/40-600 601 1.25 713913 2 729191 5 31
*EAN-code=732167+Part.no+C (control figure)

Use and installation

Used for installation of light fittings under tray or trunking. For mounting of light fittings between and under two trays or lighting
Can easily be moved along the tray or trunking. trunking. The light fitting is easily moved along the tray or lighting
trunking.

45
Cable tray W1/60, unperforated
WEF-0001
Side height 60 mm, length 2000 mm.
Holes Ø 5.8 mm at the tray ends can be used for locking of joints.

Plate Pre-galv.
A L thickness Pre-galv. White30 Weight kg
mm mm mm Part. No. C* Part. No. C* 100 m
Cable tray W1/60-70 70 2000 1.0 781999 7 782011 5 165
Cable tray W1/60-100 100 2000 1.0 782000 9 782012 2 185
Cable tray W1/60-200 200 2000 1.25 782001 6 782013 9 335
Cable tray W1/60-300 300 2000 1.25 723974 0 782014 6 440
Cable tray W1/60-400 400 2000 1.25 723975 7 782015 3 540
Cable tray W1/60-500 500 2000 1.5 723976 4 782016 0 755
Cable tray W1/60-600 600 2000 1.5 723977 1 782017 7 870
Cable tray W1/60-500 FS 500 2000 1.5 782046 7 782048 1 760
Cable tray W1/60-600 FS 600 2000 1.5 782047 4 782049 8 875
*EAN-code=732167+Part.no+C (control figure)

Use and installation

Cable tray W1/60 is joined with For trays 300 mm and wider we
2 Side joints W49/60 or Support recommend to use Support
bracket/joint W7/60. bracket/joint W7/60.

46
Cable tray W3/60, perforated
WEF-0001
Side height 60 mm, length 3000 mm.
Holes Ø 5.8 mm at the tray ends can be used for locking of joints.
Oval holes along the sides can be used for mounting of accessories.

60

Plate Pre-galv.
A L thickness Pre-galv. White30 Weight kg
mm mm mm Part. No. C* Part. No. C* 100 m
Cable tray W3/60-70 70 3000 1.0 782202 7 782306 2 150
Cable tray W3/60-100 100 3000 1.0 782203 4 782307 9 180
Cable tray W3/60-150 150 3000 1.0 782204 1 782308 6 200
Cable tray W3/60-200 200 3000 1.0 782205 8 782309 3 240
Cable tray W3/60-300 300 3000 1.25 782206 5 782310 9 337
Cable tray W3/60-400 400 3000 1.25 782207 2 782311 6 440
*EAN-code=732167+Part.no+C (control figure)

Use and installation

Cable tray W3/60 is joined with For trays 300 mm and wider we
2 Side joints W49/60 or Support recommend to use Support
bracket/joint W7/60. bracket/joint W7/60.

47
Adjustable cantilever arm W1860
WEF-0001
For installation inside Cable tray W1/60 and W3/60.

W1860 100-200 W1860 300-600

Adjustable Pre-galv.
cantilever arm A B C D Pre-galv. White30 Weight kg
mm mm mm mm Part. No. C* Part. No. C* 100 pcs
W1860-100 89 160 70 0-25 782392 5 783504 1 47
W1860-200 189 160 70 0-50 782393 2 783505 8 65
W1860-300 289 185 95 0-50 782394 9 783506 5 123
W1860-400 389 185 95 0-50 782395 6 783507 2 142
W1860-500 489 185 95 0-50 782396 3 783508 9 161
W1860-600 589 185 95 0-50 782397 3 783509 6 180
*EAN-code=732167+Part.no+C (control figure)
Loading table for cantilever arm on wall

Mounted onto wall with Expan-


sion bolt.
Breaking load for cantilever arm
mounted onto wall - see below.

Type of Max load F at 3˚ deflection Deflection in mm vid 3˚ deflection Breaking load


cantilever arm of cantilever arm of cantilever arm
kN kg kN kg
W1860-100 1.0 100 5.2 3.0 300
W1860-200 0.8 80 10.5 2.0 200
W1860-300 1.1 110 15.7 3.0 300
W1860-400 1.0 100 20.9 2.0 200
W1860-500 0.65 65 26 1.3 130
W1860-600 0.5 50 31.5 1.0 100
Use and installation

Mounting directly onto wall. Mounting on Vertical piece 2F Mounting of two adjustable canti- When mounting cable trays -
At this type of installation the using T-bolt. The Cantilever arm lever arms on the same Vertical widths 500-600 mm - it might be
adjusting allowance of the tray is W1860 can be adjusted to a piece 2F. (Tray widths more than necessary with a reinforcement
limited. max. of 50 mm. 400 mm). of the cantilever arm. Installation
Breaking load - see table above. Use Screw set 20S if the two band and stretching screw can
trays have the same width. be used for mounting in ceiling or
At different tray widths T -bolt 26 on a vertical piece.
and Screw set W37 must be
used.

48
Support bracket W1960
WEF-0001
For installation inside Cable trays W1/60 and W3/60.

Pre-galv.
A Pre-galv. White30 Weight kg
mm Part. No. C* Part. No. C* 100 pcs
Support bracket W1960-100 89 782332 1 783166 1 19
Support bracket W1960-200 189 782333 8 783167 8 37
Support bracket W1960-300 289 782334 5 783168 5 58
Support bracket W1960-400 389 782335 2 783169 2 77
Support bracket W1960-500 489 782336 9 783170 8 96
Support bracket W1960-600 589 782337 6 783171 5 115
*EAN-code=732167+Part.no+C (control figure)
Use and installation

Tray W1/60 and W3/60 with Support bracket W1960 mounted Support bracket W1960 mounted Support bracket W1960 can be
widths of 200 to 400 are with Ceiling bracket 5, Pendant/ on Vertical piece 2 and Ceiling mounted with Vertical piece 2,
mounted with suitable Support Fixing rail 24/34 and Angle bracket 5. Screw set 22S must Pendant joint 2J, Pendant/Fixing
bracket W1960 and Pendant rail bracket W8S. Screw set 22S be used. For cable trays with rail 24/34 and Ceiling bracket 5.
W32, Pendant attachment W21 must be used. For cable trays width 500 och 600. Screw set 22S must be used. For
and Screw set W37. with width 500 and 600. cable trays with width 500 and
Trays with width 100 can be 600.
mounted with Support bracket
W1960-100, one half of Pendant
attachment W21 or Tube pen-
dant W73 and Screw set W36/
W36C.

Alternatively, Tray W1/60 and Alternatively, Tray W1/60 and Alternatively, Tray W1/60 and Tray W1/60 and W3/60 can be
W3/60 with widths 500 and 600 W3/60 with widths 500 and 600 W3/60 with widths 500 and 600 mounted on suitable Support
can be installed with suitable can be installed with suitable can be installed with suitable bracket W1960 and 2 End brack-
Support bracket W1960, Support bracket W1960, Support bracket W1960, ets WN17 as pendant. The end
Threaded rod M10 W76 and Threaded rod M10 W76 and Pendant rail W32, Pendant brackets are joined with 2 Screw
2 M10 nuts. Tube pendant attachment W73. attachment W21 and Screw set sets 22S and can be adjusted in
W37. height. The pendant can be
mounted in the support bracket
with 1 Screw set W36/W36C.

49
Support bracket/joint W7/60
Used as a support bracket or joint for Cable tray W1/60 and W3/60. WEF-0001
When joining Cable tray W1/60 FS (reinforced), Side joint W49/60 must be used.

W7/60-70,150
W7/60-100,200,300,400 W7/60-500,600

Plate Pre-galv.
A B thickness Pre-galv. White30 Weight kg
mm mm mm Part. No. C* Part. No. C* 100 pcs
Support bracket/joint W7/60-70 68 152 1.0 782209 6 782318 5 22
Support bracket/joint W7/60-100 98 200 1.0 718445 3 782319 2 33
Support bracket/joint W7/60-150 148 200 1.0 782210 2 782320 8 41
Support bracket/joint W7/60-200 198 200 1.0 718446 0 782321 5 49
Support bracket/joint W7/60-300 297 300 1.25 718447 7 782322 2 122
Support bracket/joint W7/60-400 397 300 1.25 718448 4 782323 9 152
Joint W7/60-500 498 300 1.25 782211 9 782324 6 180
Joint W7/60-600 598 300 1.25 782212 6 782325 3 210
*EAN-code=732167+Part.no+C (control figure)
Use and installation

Support bracket/joint W7/60 is If necessary trays are locked With Pendant attachment W21 Tube pendant attachment W73
used for straight joining. Push-in using Screw set W38P or installed, a complete support or the one half of Pendant
mounting. Locking plug W41. bracket is obtained. Does not attachment W21 are mounted
apply to W7/60-70,150,500 and with Screw set W36/W36C.Does
600. not apply to W7/60-500 and 600.

W7/60-500 och 600 are only End bracket WN17 can be used Support bracket/joint W7/60 is
used for joining, not as support as vertical piece on Support used to achieve an invisible
brackets. bracket/joint W7/60 mounted suspension in or in connection
Reinforced tray is to be joined with Screw set W36/W36C. with bends or junctions, here with
with Side joint W49/60. End bracket WN17 mounted as
vertical piece.

50
Side joint W49/60
WEF-0001
For straight joining of Cable tray W1/60 and W3/60.

Pre-galv.
Pre-galv. White30 Weight kg
Part. No. C* Part. No. C* 100 pcs
Side joint W49/60 782267 6 782330 7 27
*EAN-code=732167+Part.no+C (control figure)
Use and installation

2 Side joints W49/60 are used for


straight joining of Cable tray W1/60,
W1/60 FS and W3/60.
4 Screw sets W38P are required
(not included).
For trays 300 mm and wider we
recommend to use Support
bracket/joint W7/60.

Reducer W28/60
WEF-0001
Used for transition joining of Cable trays W1/60 or W3/60.

Pre-galv.
A B Pre-galv. White30 Weight kg
mm mm Part. No. C* Part. No. C* 100 pcs
Reducer W28/60-100 100 57.5 787442 2 787444 6 27
Reducer W28/60-200 200 57.5 787443 9 787445 3 36
*EAN-code=732167+Part.no+C (control figure)
Use and installation

Used together with 1 Side joint


W49/60 at one-side transition 2 Reducers W28/60 are used at
joining of Cable trays W1/60 and centered transition joining, to be
W3/60, to be mounted with mounted with Screw set W38P.
2 Screw sets W38P. Always use Always use support close to the
support close to the reducer. reducer.

51
T-joint W9/60
WEF-0001
Used for straight or oblique branches of Cable trays W1/60 or W3/60.

Plate Pre-galv.
thickness Pre-galv. White30 Weight kg
mm Part. No. C* Part. NoC* 100 pcs
T-joint W9/60 (Screw set W38P incl.) 1.25 782217 1 782218 8 5
*EAN-code=732167+Part.no+C (control figure)

Use and installation

Potential balancing T-joint W9/60 is mounted on the Straight branches. Oblique branches.
In order to fulfil the potential sides of the tray with Screw set If necessary, the lugs are locked If necessary, the lugs are locked
balancing according to W38P. to the edge of the tray using to the edge of the tray using
SS-EN 61537 the T-joint must be pliers. Can also be locked with pliers. Can also be locked with
secured with blind rivets or self-tapping blind rivets or self-tapping
1 Self-drilling screw screws. screws.
RXB 4.2x13
2 Screw set W38P,
drilling is required
Tightening torque 2 Nm

52
T-joint W29/60
WEF-0001
Simple push-in assembly. Locks into tray via locking flap.
Is hung over the edge of the tray and locked in a suitable way.

Pre-galv.
A Pre-galv. White30 Weight kg
mm Part. No. C* Part. No. C* 100 pcs
T-joint W29/60-70 68 783178 4 783185 2 22
T-joint W29/60-100 98 783179 1 783186 9 27
T-joint W29/60-200 198 783180 7 783187 6 37
T-joint W29/60-300 298 783181 4 783188 3 47
T-joint W29/60-400 398 783182 1 783189 0 57
T-joint W29/60-500 498 783183 8 783190 6 67
T-joint W29/60-600 598 783184 5 783191 3 77
*EAN-code=732167+Part.no+C (control figure)

Use and installation

Potential balancing Used with T- and X-junction.


In order to fulfil the potential Mounted directly onto tray edge.
balancing according to Can be attached to tray by
SS-EN 61537 the T-joint must be pinching the lip at the top of the
secured with tray.
1 Self-drilling screw
RXB 4.2x13
2 Screw set W38P,
drilling is required
Tightening torque 2 Nm

53
Adjustable bend W10/60
WEF-0001
For horizontal angling of Cable ladders W1/60 or W3/60.
Push-in installation.

Plate Pre-galv.
A thickness Pre-galv. White30 Weight kg
mm mm Part. No. C* Part. No C* 100 pcs
Adjustable bend W10/60-70 67 1.0 782268 3 782471 7 17
Adjustable bend W10/60-100 97 1.0 782269 0 782472 4 23
Adjustable bend W10/60-150 147 1.0 782270 6 782473 1 37
Adjustable bend W10/60-200 197 1.0 782271 3 782474 8 53
Adjustable bend W10/60-300 297 1.0 782272 0 782475 5 97
Adjustable bend W10/60-400 397 1.0 782273 7 782476 2 156
Adjustable bend W10/60-500 497 1.25 782274 4 782477 9 292
Adjustable bend W10/60-600 597 1.25 782275 1 782478 6 406
*EAN-code=732167+Part.no+C (control figure)

Use and installation

Push-in installation. Turn up Adjustable bend W10/60 permits If necessary, Adjustable bend
inner and outer sides and mount desired horizontal angling W10/60 may be locked using
the Adjustable bend W10/60 between 105˚ and 165˚ in stages Screw set W38P or Locking plug
inside the tray. of 7.5˚. W41.

54
Vertical riser W11/60
WEF-0001
For upward or downward branching of Cable trays W1/60 or W3/60 to desired angle.
Push-in assembly.

Plate Pre-galv.
A L thickness Pre-galv. White30 Weight kg
mm mm mm Part. No. C* Part. No. C* 100 pcs
Vertical riser W11/60-70 67 150 0.7 782276 8 782593 6 12
Vertical riser W11/60-100 97 150 0.7 782277 5 782594 3 15
Vertical riser W11/60-150 147 150 0.7 782278 2 782595 0 19
Vertical riser W11/60-200 197 200 0.7 782279 9 782596 7 31
Vertical riser W11/60-300 297 200 0.7 782280 5 782597 4 42
Vertical riser W11/60-400 397 200 0.7 782281 2 782598 1 53
Vertical riser W11/60-500 497 200 0.7 782282 9 782599 8 64
Vertical riser W11/60-600 597 200 0.7 782283 6 782600 1 75
*EAN-code=732167+Part.no+C (control figure)

Use and installation

Vertical riser W11/60 is delivered For upward or downward Should be attached with Screw
flat and must be bent by the branching at a desired angle up set W38P or Locking plug W41.
installer on the job site. to 90˚. Push-in installation.

55
90˚ bend W10/60
WEF-0001
For 90˚ horizontal angling of Cable trays W1/60 or W3/60.
Push-in assembly.

Plate Pre-galv.
A B thickness Pre-galv. White30 Weight kg
mm mm mm Part. No. C* Part. No. C* 100 pcs
90˚ bend W10/60-70 67 167 1.25 782038 2 782408 3 43
90˚ bend W10/60-100 97 197 1.25 782039 9 782409 0 55
90˚ bend W10/60-150 147 247 1.25 782040 5 782410 6 85
90˚ bend W10/60-200 197 297 1.25 782041 2 782411 3 117
90˚ bend W10/60-300 297 397 1.25 782042 9 782412 0 196
90˚ bend W10/60-400 397 497 1.25 782043 6 782413 7 295
90˚ bend W10/60-500 497 597 1.25 782044 3 782414 4 413
90˚ bend W10/60-600 597 697 1.25 782045 0 782415 1 551
90˚ bend W10/60-500 FS 497 597 1.25 782458 8 787188 9 343
90˚ bend W10/60-600 FS 597 697 1.25 782459 5 787189 6 465
*EAN-code=732167+Part.no+C (control figure)

Use and installation

Used for 90˚ horizontal angling. If necessary, the 90˚ bend Support bracket/joint W7/60, with
Suspension components should W1060 can be locked using a suitable pendant, is used to
be mounted in or in connection Screw set W38P or Locking achieve an invisible suspension,
with the bend. plug W41. Can be provided with here with End bracket WN17
Push-in installation. holes in bottom for suspension mounted as vertical piece.
in Pendant attachment W21
alternatively W73.
Valid for max. width 200 mm.

56
T-junction W12/60
WEF-0001
For 90˚ horizontal junction of Cable trays W1/60 or W3/60.
Push-in assembly.

Plate Pre-galv.
A thickness Pre-galv. White30 Weight kg
mm mm Part. No. C* Part. No. C* 100 pcs
T-junction W12/60-70 67 1.25 782052 8 782424 3 54
T-junction W12/60-100 97 1.25 782053 5 782425 0 70
T-junction W12/60-150 147 1.25 782054 2 782426 7 99
T-junction W12/60-200 197 1.25 782055 9 782427 4 133
T-junction W12/60-300 297 1.25 782056 6 782428 1 217
T-junction W12/60-400 397 1.25 782057 3 782429 8 320
T-junction W12/60-500 497 1.25 782058 0 782430 4 443
T-junction W12/60-600 597 1.25 782059 7 782431 1 585
T-junction W12/60-500 FS 497 1.25 782460 1 787192 6 337
T-junction W12/60-600 FS 597 1.25 782461 8 787193 3 454
*EAN-code=732167+Part.no+C (control figure)

Use and installation

Used for 90˚ horizontal junction. If necessary, the junction can be Support bracket/joint W7/60, with
Suspension components should locked using Screw set W38P a suitable pendant, is used to
be mounted in or in connection or Locking plug W41. Can be achieve an invisible suspension,
with the junction. provided with holes in bottom for here with End bracket WN17
Push-in installation. suspension in Pendant attach- mounted as vertical piece.
ment W21 alternatively W73.
Valid for max. width 200 mm.

57
X-junction W13/60
WEF-0001
For 90˚ horizontal junction of Cable trays W1/60 or W3/60.
Push-in assembly.

Plate Pre-galv.
A B thickness Pre-galv. White30 Weight kg
mm mm mm Part. No. C* Part. No. C* 100 pcs
X-junction W13/60-70 67 268 1.25 782095 5 782440 3 62
X-junction W13/60-100 97 298 1.25 782096 2 782441 0 78
X-junction W13/60-150 147 348 1.25 782097 9 782442 7 110
X-junction W13/60-200 197 398 1.25 782098 6 782443 4 146
X-junction W13/60-300 297 498 1.25 782099 3 782444 1 234
X-junction W13/60-400 397 598 1.25 782100 6 782445 8 342
X-junction W13/60-500 497 698 1.25 782101 3 782446 5 469
X-junction W13/60-600 597 798 1.25 782102 0 782447 2 616
X-junction W13/60-500 FS 497 698 1.25 782462 5 787196 4 328
X-junction W13/60-600 FS 597 798 1.25 782463 2 787197 1 441
*EAN-code=732167+Part.no+C (control figure)

Use and installation

Used for 90˚ horizontal junction If necessary, the junction can be Support bracket/joint W7/60, with
of four trays with the same width. locked using Screw set W38P a suitable pendant, is used to
Suspension components should or Locking plug W41. Can be achieve an invisible suspension,
be mounted in or in connection provided with holes in bottom for here with End bracket WN17
with the junction. suspension in Pendant attach- mounted as vertical piece.
Push-in installation. ment W21 alternatively W73.
Valid for max. width 200 mm.

58
Reducing piece W14/60 left
WEF-0001
Push-in assembly fitted for transition between different widths of Cable trays W1/60 or W3/60.

Plate Pre-galv.
A B thickness Pre-galv. White30 Weight kg
mm mm mm Part. No. C* Part. No. C* 100 pcs
Reducing piece W14/60 200-100 left 197 97 1.25 782163 1 782517 2 89
Reducing piece W14/60 300-100 left 297 97 1.25 782164 8 782518 9 139
Reducing piece W14/60 400-100 left 397 97 1.25 782165 5 782519 6 198
Reducing piece W14/60 300-200 left 297 197 1.25 782166 2 782520 2 123
Reducing piece W14/60 400-200 left 397 197 1.25 782167 9 782521 9 183
Reducing piece W14/60 400-300 left 397 297 1.25 782168 6 782522 6 158
*EAN-code=732167+Part.no+C (control figure)

Use and installation

Used for transition between If necessary, the Reducing piece Suspension components should
different widths of trays during W14/60 can be locked using be mounted in or in connection
wall mounting. Screw set W38P or Locking plug with the reducing piece.
Push-in installation. W41. Support bracket/joint W7/60,
mounted with a suitable pendant,
is used to achieve an invisible
suspension, here with End
bracket WN17 mounted as
vertical piece.

59
Reducing piece W14/60 right
WEF-0001
Push-in assembly fitted for transition between different widths
of Cable trays W1/60 or W3/60.

Plate Pre-galv.
A B thickness Pre-galv. White30 Weight kg
mm mm mm Part. No. C* Part. No. C* 100 pcs
Reducing piece W14/60 200-100 right 197 97 1.25 782153 2 782505 9 89
Reducing piece W14/60 300-100 right 297 97 1.25 782154 9 782506 6 139
Reducing piece W14/60 400-100 right 397 97 1.25 782155 6 782507 3 198
Reducing piece W14/60 300-200 right 297 197 1.25 782156 3 782508 0 123
Reducing piece W14/60 400-200 right 397 197 1.25 782157 0 782509 7 183
Reducing piece W14/60 400-300 right 397 297 1.25 782158 7 782510 3 158
*EAN-code=732167+Part.no+C (control figure)

Use and installation

Used for transition between If necessary, the Reducing piece Suspension components should
different widths of trays during W14/60 can be locked using be mounted in or in connection
wall mounting. Screw set W38P or Locking plug with the reducing piece.
Push-in installation. W41. Support bracket/joint W7/60,
mounted with a suitable pendant,
is used to achieve an invisible
suspension, here with End
bracket WN17 mounted as
vertical piece.

60
Reducing piece W15/60 straight
WEF-0001
Push-in assembly fitted for transition between different widths of Cable trays W1/60 or W3/60.

Plate Pre-galv.
A B thickness Pre-galv. White30 Weight kg
mm mm mm Part. No. C* Part. No. C* 100 pcs
Reducing piece W15/60 200-100 straight 197 97 1.25 782104 4 782491 5 76
Reducing piece W15/60 300-100 straight 297 97 1.25 782105 1 782492 2 122
Reducing piece W15/60 400-100 straight 397 97 1.25 782106 8 782493 9 179
Reducing piece W15/60 300-200 straight 297 197 1.25 782107 5 782494 6 105
Reducing piece W15/60 400-200 straight 397 197 1.25 782108 2 782495 3 162
Reducing piece W15/60 400-300 straight 397 297 1.25 782109 9 782496 0 134
*EAN-code=732167+Part.no+C (control figure)

Use and installation

Used for transition between If necessary, the Reducing piece Suspension components should
different tray widths during W15/60 can be locked using be mounted in or in connection
symmetric ceiling installation. Screw set W38P or Locking plug with the reducing piece.
Push-in assembly. W41. Support bracket/joint W7/60,
mounted with a suitable pendant,
is used to achieve an invisible
suspension, here with End
bracket WN17 mounted as
vertical piece.

61
End cover W45/60
WEF-0001
Push-in assembly mounted as end cover in Cable trays W1/60 or W3/60.

Plate Pre-galv.
A thickness Pre-galv. White30 Weight kg
mm mm Part. No. C* Part. No. C* 100 pcs
End cover W45/60-70 68 1.0 782292 8 786771 4 12
End cover W45/60-100 98 1.0 782293 5 786772 1 13
End cover W45/60-200 198 1.0 782294 2 786773 8 18
End cover W45/60-300 298 1.0 782295 9 786774 5 23
End cover W45/60-400 398 1.0 782296 6 786775 2 28
End cover W45/60-500 498 1.0 782297 3 786776 9 34
End cover W45/60-600 598 1.0 782298 0 786777 6 39
*EAN-code=732167+Part.no+C (control figure)

Use and installation

Mounted as end cover in cable


trays. Locked with Screw set
W38P or Locking plug W41.

62
Junction box plate W24/60
WEF-0001
Used for installing junction boxes, light fittings etc. in Cable
trays W1/60 or W3/60.

Plate Pre-galv.
thickness Pre-galv. White30 Weight kg
mm Part. No. C* Part. No. C* 100 pcs
Junction box plate W24/60 1.0 718193 3 782659 9 34
*EAN-code=732167+Part.no+C (control figure)

Use and installation

The Junction box plate W24/60 is If necessary, the Junction box Can be mounted in the middle To firmly attach Junction box
mounted between the bottom of plate W24/60 can be tightened of Tray W3/60 with Screw set plate W24/60 in Tray W1/60
the tray and its folded seam. directly in Tray W3/60 with Screw W38P. or W3/60, use blind rivets, self-
set W38P. If one requires a tapping screws or Screw set
hidden socket box, the junction W38P.
box should be folded inwards.

63
Dividing strip 39/55
WEF-0001
Mounted to divide Cable trays W1/60 or W3/60.

Plate Pre-galv.
thickness H Pre-galv. White30 Weight kg
mm mm Part. No. C* Part. No. C* 100 pcs
Dividing strip 39/55 0.6 55 725785 0 782787 9 73
*EAN-code=732167+Part.nr+C (control figure)
Use and installation

Used to separate tray in two or


more ducts, thereby separating
control cables from other cables
and pipes. The hole structure at
distances of 250 mm permits two
fixing opportunities with Support
band W6 even after cutting.

Support band W6
WEF-0001
The Support band W6 is mounted to fix the lateral position of one or several Dividing strips 39/55.

L Pre-galv. Weight kg
mm Part. No. C* 100 pcs
Support band W6-70 67 718828 4 1.0
Support band W6-100 97 718829 1 1.4
Support band W6-200 197 718830 7 2.8
Support band W6-300 297 718831 4 4.3
Support band W6-400 397 718832 1 5.7
Support band W6-500 497 718833 8 7.2
Support band W6-600 597 718834 5 8.6
*EAN-code=732167+Part.no+C (control figure)
Use and installation

Support band W6 is mounted to


fix one or more Dividing strips 39
laterally. The holes in the support
band and the locking pins in
Dividing strip 39 allow for a fixed
division with intervals of 25 mm.

64
Insert piece W39/55
WEF-0001
Insert piece W39/55 is used to join Dividing strips 39/55.

Pre-galv. Pre-galv. White30 Weight kg


Part. No. C* Part. No. C* 100 pcs
Insert piece W39/55 782299 7 786873 5 19
*EAN-code=732167+Part.no+C (control figure)
Use and installation

Insert piece W39/55 is used to


join Dividing strips 39/55 and is
mounted on Support bracket/joint
W7/60.

Luminaire bracket W25/60


Used for assembly of light fittings under Cable trays W1/60 and W3/60. WEF-0001

Plate Pre-galv.
A thickness Pre-galv. White30 Weight kg
mm mm Part. No. C* Part. No. C* 100 pcs
Luminaire bracket W25/60-70 72 1.25 782284 3 782614 8 7.7
Luminaire bracket W25/60-100 101 1.25 782285 0 782615 5 8.6
Luminaire bracket W25/60-200 201 1.25 782286 7 782616 2 14
Luminaire bracket W25/60-300 301 1.25 782287 4 782617 9 18
Luminaire bracket W25/60-400 401 1.25 782288 1 782618 6 23
Luminaire bracket W25/60-500 501 1.25 782289 8 782619 3 27
Luminaire bracket W25/60-600 601 1.25 782290 4 782620 9 32
*EAN-code=732167+Part.no+C (control figure)
Use and installation

For mounting of lighting fittings


The luminaire bracket can easily under Cable tray W1/60 and
be moved along the tray. W3/60.

65
Cover strip W47/60
WEF-0001
Used for covering space between joined Cable trays W1/60 or W3/60.

Plate Pre-galv.
B thickness Pre-galv. White30 Weight kg
mm mm Part. No. C* Part. No. C* 100 pcs
Cover strip W47/60-70 71.5 1.0 786799 8 786806 3 8
Cover strip W47/60-100 101.5 1.0 786800 1 786807 0 9
Cover strip W47/60-200 202 1.0 786801 8 786808 7 12
Cover strip W47/60-300 302 1.0 786802 5 786809 4 15
Cover strip W47/60-400 402 1.0 786803 2 786810 0 18
Cover strip W47/60-500 502.5 1.0 786804 9 786811 7 21
Cover strip W47/60-600 602.5 1.0 786805 6 786812 4 24
*EAN-code=732167+Part.no+C (control figure)
Use and installation

Cover strip W47/60 is mounted


to cover the space that might
occur when joining cable trays.

66
Lighting trunking W70

67
Lighting trunking W70
WEF-0001
Use Support bracket W7/40 for joining.

Pre-galv.
A B C D t L Pre-galv. White30 Weight kg
mm mm mm mm mm mm Part. No. C* Part. No. C* 100 m
Lighting trunking W70-40 40 22 10.5 6 1.5 2995 720980 4 729023 9 107
Lighting trunking W70-70 70 40 8.5 5 1 3000 720792 3 729024 6 125
Lighting trunking W70-100 100 40 8.5 5 1 3000 720793 0 729025 3 147
Lighting trunking W70-200 200 40 8.5 5 1 3000 720794 7 729026 0 220

ZINKPOX®
A B C D t L Hot dip galv. White80 Weight kg
mm mm mm mm mm mm Part. No. C* Part. No. C* 100 m
Lighting trunking W70-40 40 22 10.5 6 1.5 2995 790067 1 790071 8 113
Lighting trunking W70-70 70 40 8.5 5 1 3000 790068 8 790072 5 133
Lighting trunking W70-100 100 40 8.5 5 1 3000 790069 5 790073 2 157
Lighting trunking W70-200 200 40 8.5 5 1 3000 790079 1 790074 9 237
*EAN-code=732167+Part.no+C (control figure)
Load capacity

Downward deflection refers to outer compartment Downward deflection refers to middle compartment

K = Bracket distance

Installation method K = 1.5 m Installation method K = 3 m suspended in joints


Load kg Deflection mm Load kg Deflection mm
W70/70-200 W70-40 W70/70-200 W70-40 W70/70-200 W70-40 W70/70-200 W70-40
A 25 20 1.5 2 25 10 15 15
50 40 3.5 4.5 50 20 30 31
B 30 20 1 2.5 30 10 7 4
60 40 2.5 5 60 20 14 8
C 20 20 2 3 20 10 13 19
40 40 4 6.5 40 20 26 38
D Breaking load for Support bracket/joint W7/40-70 = 120 kg

68
Lighting trunking W71
WEF-0001
Use Support bracket W7/40 for joining.

Pre-galv.
A B C D t L Pre-galv. White30 Weight kg
mm mm mm mm mm mm Part. No. C* Part. No. C* 100 m
Lighting trunking W71-70 70 40 8.5 6 1 6000 734511 3 734513 7 130
Lighting trunking W71-100 100 40 8.5 6 1 6000 734512 0 734514 4 153
*EAN-code=732167+Part.no+C (control figure)

Load capacity

Downward deflection refers to outer compartment Downward deflection refers to middle compartment

K = Bracket distance

Installation method K = 1.5 m Installation method K = 3 m suspended in joints


Load kg Deflection mm Load kg Deflection mm
W71/70-100 W71/70-100 W71/70-100 W71/70-100
A 25 1.5 25 15
50 3.5 50 30
B 30 1 30 7
60 2.5 60 14
C 20 2 20 13
40 4 40 26
D Breaking load for Support bracket/Joint W7/40-70 = 120 kg

69
Support bracket W20
WEF-0001
For invisible installation of Lighting trunking W70/71, width 70 and 100 mm.
The support bracket is snapped firmly into the trunking. Threaded rod M10 W76 is used.

W20-70 W20-100

Pre-galv. Weight kg
Part. No. C* 100 pcs
Support bracket W20-70 (2 nuts M10 are included) 720973 6 9
Support bracket W20-100 (2 nuts M10 are included) 721943 8 13
*EAN-code=732167+Part.no+C (control figure)
Use and installation

Support bracket W20-70 is Lightly press down Support bracket W20-70 into Lighting trunking Support bracket W20-100 is
mounted with Threaded rod M10 W70/W71-70. mounted with Threaded rod M10
W76 and 2 M10 nuts. W76 with 2 M10 nuts.

Support bracket W20A


WEF-0001
For invisible installing of Lighting trunking W70/W71, width 70 and 100 mm. Threaded rod M10 W76 is used.
The support bracket’s spring locking device facilitates easy vertical adjustment.

W20A-70 W20A-100

Pre-galv.
Pre-galv. White30 Weight kg
Part. No. C* Part. No. C* 100 pcs
Support bracket W20A-70 720970 5 729027 7 15
Support bracket W20A-100 721180 7 729028 4 20
*EAN-code=732167+Part. No.+C (control figure)
Use and installation

Support brackets W20A-70 and Lightly press down Support bracket W20A-70 into Lighting trunking Support bracket W20A-100
W20A-100 are mounted on W70/W71-70. is easily snapped firmly into
Threaded rod M10 W76. This Lighting trunking W70/W71-100.
enables simple vertical adjust-
ment of ±30 mm.
70
Pendant brackets W80 and W81
WEF-0001
Used together with Lighting trunking W70-40.

Pre-galv.
Pre-galv. White30 Weight kg
Part. No. C* Part. No. C* 100 pcs
Pendant bracket W80 718474 3 729056 7 9
Pendant bracket W81 718477 4 729057 4 8
*EAN-code=732167+Part.no+C (control figure)
Use and installation
(Only for Lighting trunking W70-40)

Pendant bracket W80 mounted


under Lighting trunking W70-40 Pendant bracket W81 is
and attached with Screw set mounted under Lighting trunking
W36/W36C. Threaded rod M10 W70-40 and is attached with
W76 is easily mounted in the Screw set W36/W36C. Pendant
spring clasp without bolts. rail W32 is mounted using Screw
Adjustable to ±30 mm. set W37. Adjustable to ±18 mm.

Luminaire bracket W35


WEF-0001
For mounting of strip lighting centred under Lighting trunking W70/W71.
Use Screw set W36/W36C or W34.

Plate
thickness Pre-galv. Weight kg
mm Part. No. C* 100 pcs
Luminaire bracket W35 1.5 715650 4 3
*EAN-code=732167+Part.no+C (control figure)
Use and installation

Mounted in the rail’s module


holes with Screw set W36/W36C
or W34.
Note! The fork openings must be
mounted in the same direction.

71
Luminaire bracket W55
WEF-0001
Used for mounting of light fittings under Lighting trunking W70.

Electro-galv. Weight kg
Part. No. C* 100 pcs
Luminaire bracket W55 720979 8 0.8
*EAN-code=732167+Part.no+C (control figure)
Use and installation

Mounted in the mounting holes in Always mount the Luminaire


Lighting trunking W70. bracket W55 from above so that
it rests in the tray.

Luminaire bracket W56


WEF-0001
Used for installation of light fittings in Lighting trunking W71.

Aluminium Weight kg
Part. No. C* 100 pcs
Luminaire bracket W56 (screw MSCS6x12) 734565 6 1
*EAN-code=732167+Part.no+C (control figure)
Use and installation

Always mount the Luminaire


bracket W56 from above so that
it rests in the tray.

72
Installation tray W4

73
Installation tray W4,
outline of assembly

Components
1. Cantilever arm 50
2. Installation tray W4
3. Joint W2
4. 90˚ bend W4
5. Vertical riser W4, interior
6. Vertical riser W4, exterior
7. Angle bracket W8
8. Screw set W38P
9. Screw set W34

74
Installation tray W4
WEF-0001
Wibe installation trays W4 are perforated with a hole structure suitable for the majority of clamping methods.
Suitable even for vertical wall mounting in industries, in lifts and fan rooms.
Holes Ø 3.5 mm in the tray bottom allow clamping of cables with plate screws.
The tray can also be used for horizontal mounting on cantilever arms.
Maximum bracket distance 1.5 m. Joints are to be mounted on the cantilever.
A varity of colours can be offered.

Pre-galv. ZINKPOX®
L A t Pre-galv. Hot dip galv. White30 White80 Weight kg
mm mm mm Part. No. C* Part. No. C* Part. No. C* Part. No. C* 100 m
Installation tray W4-50 3000 50 1.0 735988 2 735977 6 787227 5 735999 8 57
Installation tray W4-75 3000 75 1.0 735989 9 735978 3 787228 2 736000 0 76
Installation tray W4-100 3000 100 1.0 735990 5 735979 0 787229 9 736001 7 93
Installation tray W4-150 3000 150 1.0 735991 2 735980 6 787230 5 736002 4 125
Installation tray W4-200 3000 200 1.25 735992 9 735981 3 787231 2 736003 1 195
Installation tray W4-250 3000 250 1.25 735993 6 735982 0 787232 9 736004 8 228
Installation tray W4-300 1960 300 1.25 736609 5 736619 4 736639 2 736005 5 238
Installation tray W4-400 1960 400 1.25 736610 1 736620 0 736640 8 736006 2 313
*EAN-code=732167+Part.no+C (control figure)

Use and installation

Suitable for leading cables down


from a cable ladder to machine
cabinet etc.

75
Joint W2
WEF-0001
For joining of Installation tray W4.

Plate Pre-galv. ZINKPOX®


thickness Pre-galv. Hot dip galv. White30 White80 Weight kg
mm Part. No. C* Part. No. C* Part. No. C* Part. No. C* 100 pcs
Joint W2 1.25 788572 5 788573 2 788574 9 788575 8 8
*EAN-code=732167+Part.no+C (control figure)

Use and installation

Used for joining Tray W4. To be


mounted on the outside of the
tray and attached in bottom with
2 Screw sets W34/W38P.

76
90˚ bend W4
WEF-0001
For horizontal 90˚ angling of Installation tray W4.

Pre-galv. ZINKPOX®
A Pre-galv. Hot dip galv. White30 White80 Weight kg
mm Part. No. C* Part. No. C* Part. No. C* Part. No. C* 100 pcs
90˚ bend W4-50 52 724848 3 724981 7 729095 6 782930 9 12
90˚ bend W4-75 77 724849 0 724982 4 729096 3 782931 6 19
90˚ bend W4-100 102 724850 6 724983 1 729097 0 782932 3 26
90˚ bend W4-150 152 724851 3 724984 8 729098 7 782933 0 44
90˚ bend W4-200 202 724852 0 724985 5 729099 4 782934 7 66
90˚ bend W4-250 252 724853 7 724986 2 729100 7 782935 4 92
90˚ bend W4-300 302 724854 4 724987 9 729101 4 782936 1 121
90˚ bend W4-400 402 724855 1 724988 6 729102 1 782937 8 192
*EAN-code=732167+Part.no+C (control figure)
Use and installation

Used for horizontal 90˚ angling.


Mounted outside of W4 trays.
Attached in bottom with Screw
set W34 (pre-galvanized and
powder coated trays).
In hot dip galvanized trays Screw
set W38P must be used.

77
Vertical riser W4, interior
WEF-0001
For vertical 90˚ angling of Installation tray W4.

Pre-galv. ZINKPOX®
A Pre-galv. Hot dip galv. White30 White80 Weight kg
mm Part. No. C* Part. No. C* Part. No. C* Part. No. C* 100 pcs
Vertical riser W4-50, interior 52 724840 7 724934 3 729110 6 782950 7 18
Vertical riser W4-75, interior 77 724841 4 734935 0 729111 3 782951 4 24
Vertical riser W4-100, interior 102 724842 1 734936 7 729112 0 782952 1 30
Vertical riser W4-150, interior 152 724843 8 724937 4 729113 7 782953 8 41
Vertical riser W4-200, interior 202 724844 5 727938 1 729114 4 782954 5 53
Vertical riser W4-250, interior 252 724845 2 724939 8 729115 1 782955 2 65
Vertical riser W4-300, interior 302 724846 9 724940 4 729116 8 782956 9 76
Vertical riser W4-400, interior 402 724847 6 724941 1 729117 5 782957 6 99
*EAN-code=732167+Part.no+C (control figure)

Use and installation

Used for vertical 90˚ angling. Used for vertical 90˚ angling from
Mounted outside of trays W4. cable ladder. Attached to cable
Attached in bottom with Screw ladders with strips.
set W34 (pre-galvanized and
powder coated trays).
In hot dip galvanized trays Screw
set W38P must be used.

78
Vertical riser W4, exterior
WEF-0001
For vertical 90˚ angling of Installation tray W4.

Pre-galv. ZINKPOX®
A Pre-galv. Hot dip galv. White30 White80 Weight kg
mm Part. No. C* Part. No. C* Part. No. C* Part. No. C* 100 pcs
Vertical riser W4-50, exterior 52 724832 2 724926 8 729118 2 782970 5 18
Vertical riser W4-75, exterior 77 724833 9 724927 5 729119 9 782971 2 24
Vertical riser W4-100, exterior 102 724834 6 724928 2 729120 5 782972 9 30
Vertical riser W4-150, exterior 152 724835 3 724929 9 729121 2 782973 6 41
Vertical riser W4-200, exterior 202 724836 0 724930 5 729122 9 782974 3 53
Vertical riser W4-250, exterior 252 724837 7 724931 2 729123 6 782975 0 65
Vertical riser W4-300, exterior 302 724838 4 724932 9 729124 3 782976 7 76
Vertical riser W4-400, exterior 402 724839 1 724933 6 729125 0 782977 4 99
*EAN-code=732167+Part.no+C (control figure)

Use and installation

Used for vertical 90˚ angling. Used for vertical 90˚ angling from
Mounted outside of Trays W4. cable ladder. Attached to cable
Attached in bottom with Screw ladders with strips.
set W34 (pre-galvanized and
powder coated trays). In hot dip
galvanized trays Screw set
W38P must be used.

79
Cantilever arm 50
WEF-0001
For mounting on walls, pendant/fixing rails or vertical pieces.

50L,50/100-300 50L,50/400-600 50L,50/700-1000

ZINKPOX®
A F H T Hot dip galv. White80 Weight kg
mm mm mm mm Part. No. C* Part. No. C* 100 pcs
Cantilever arm 50L-100 150 34 85 4 725105 6 725113 1 24
Cantilever arm 50L-150 200 36 85 4 725106 3 725114 8 28
Cantilever arm 50L-200 250 39 85 4 725107 0 725115 5 34
Cantilever arm 50L-250 298 56 105 4 725108 7 725116 2 46
Cantilever arm 50L-300 348 60 105 4 725109 4 725117 9 54
Cantilever arm 50L-400 447 70 120 5 725110 0 725118 6 103
Cantilever arm 50L-500 548 77 140 6 725111 7 725119 3 160
Cantilever arm 50L-600 646 84 150 6 725112 4 725120 9 191
Cantilever arm 50-100 150 34 85 4 723432 5 723440 0 24
Cantilever arm 50-150 200 36 85 4 723433 2 723441 7 28
Cantilever arm 50-200 250 39 85 4 723434 9 723442 4 34
Cantilever arm 50-250 300 56 105 6 723435 6 723443 1 52
Cantilever arm 50-300 350 60 105 6 723436 3 723444 8 60
Cantilever arm 50-400 450 70 120 8 723437 0 723445 5 118
Cantilever arm 50-500 550 77 140 8 723438 7 723446 2 172
Cantilever arm 50-600 650 84 150 10 723439 4 723447 9 215
Cantilever arm 50-700 750 90 150 10 727125 2 727782 7 270
Cantilever arm 50-800 850 95 160 10 727126 9 727783 4 310
Cantilever arm 50-900 950 100 160 10 727127 6 727784 1 350
Cantilever arm 50-1000 1050 105 170 10 727128 3 727785 8 390
*EAN-code=732167+Part.no+C (control figure)

80
Cantilever arm 50
Use and installation

F F
F

Installation of a Cantilever arm Installation of a Cantilever arm Installation of Cantilever arm 50


50 to a wall using an Expansion 50 using a T-bolt on pendant/ using T-bolt with vertical pieces.
bolt. fixing rails mounted on the wall. Breaking load F, see table below.
Breaking load F, see table below. Breaking load F, see table below. Also check the breaking load of
vertical pieces.

Breaking load F
F

Type of Mounted on P/F rail 24/48


cantilever arm Mounted on wall with T-bolt 26F
kN kg kN kg
50L-100 1.5 150 1.5 150
50L-150 1.5 150 1.5 150
50L-200 1.5 150 1.5 150
50L-250 2.0 200 2.0 200
50L-300 2.0 200 2.0 200
50L-400 3.0 300 3.0 300
50L-500 3.0 300 3.0 300
50L-600 3.0 300 3.0 300
50-100 3.0 300 3.0 300
50-150 3.0 300 3.0 300
50-200 2.5 250 2.5 250
50-250 4.0 400 4.0 400
50-300 4.0 400 4.0 400
50-400 6.5 650 6.5 650
50-500 7.0 700 7.0 700
50-600 7.0 700 7.0 700
50-700 6.0 600 5.5 550
50-800 5.5 550 5.2 520
50-900 5.3 530 4.8 480
50-1000 5.0 500 4.2 420

81
Cantilever arm 80
WEF-0001
For installation of Cable trays W1 and W3.
The cantilever arm can be mounted on Vertical piece 7/7L or Wall bracket 80.
(Screw set 22S not included)

L H Pre-galv. Hot dip galv. Weight kg


mm mm Part. No. C* Part. No. C* 100 pcs
Cantilever arm 80-100 155 70 730448 6 732124 7** 12
Cantilever arm 80-150 205 71 730449 3 732125 4** 16
Cantilever arm 80-200 255 70 730450 9 732126 1** 20
Cantilever arm 80-250 305 70 730451 6 732127 8** 28
Cantilever arm 80-300 355 70 730452 3 732128 5** 35
Cantilever arm 80-400 455 80 730453 0 732129 2** 50
Cantilever arm 80-500 555 90 730454 7 732130 8** 65
Cantilever arm 80-600 655 100 730455 4 732131 5** 110
* EAN-code=732167+Part.no+( (control figure) **Produced to order

Use and installation

Cantilever arm 80 mounted on Cantilever arm 80 can also be When mounting Cantilever arm
Vertical piece 7/7L with Screw mounted on both sides of Vertical 80 on wall, Wall bracket 80 shall
set 22S. Infinitely adjustable piece 7 at the same level. be used together with Screw set
along the vertical piece. Breaking 22S.
load see loading table below. Breaking load see loading table
below.

Breaking load F

Type of Mounted on Mounted at the end of Mounted along


Cantilever arm Wall bracket 80 Vertical piece 7/7L the Vertical piece 7/7L
kN kg kN kg kN kg
80-100 2.5 250 2.5 250 2.3 230
80-150 2.3 230 2.5 250 2.3 230
80-200 2.2 220 2.5 250 2.3 230
80-250 2.0 200 2.0 200 2.0 200
80-300 1.9 190 2.2 220 2.0 200
80-400 1.7 170 1.9 190 1.8 180
80-500 1.7 170 1.9 190 1.8 180
80-600 1.7 170 1.9 190 1.6 160

82
Wall bracket 80
For installation of Cantilever arm 80 on wall. WEF-0001
Fits all widths. (Screw set 22S not included.)

Pre-galv. Hot dip galv. Weight kg


Part. No. C* Part. No. C* 100 pcs
Wall bracket 80 729216 5 733209 0** 23
* EAN-code=732167+Part.no+C (control figure) **Produced to order
Use and installation

Wall bracket 80 shall be


mounted with Screw set 22S.
Breaking load see loading table
for Cantilever arm 80.

Back plate W30


For installation behind internal cantilever arms to reduce the WEF-0001
surface pressure on porous walls.

Pre-galv.
t Pre-galv. White30 Weight kg
mm Part. No. C * Part. No. C * 100 pcs
Back plate W30 3.0 786792 9 786793 6 42
*EAN-code=732167+Part.no+C (control figure)
Use and installation

Mount Back plate W30 as shown


in the illustration to reduce the
surface stress on porous walls.

83
Mounting rail 40
Mounting rail 40 is installed between a cantilever arm and wall to reduce surface WEF-0001
pressure on porous walls or to enable height adjustment of cantilever arms.

ZINKPOX® ZINKPOX®
Hot dip galv. White30 White80 Weight kg
Part. No. C* Part. No. C* Part. No C* 100 pcs
Mounting rail 40 717001 2 729045 1 717006 7 56
*EAN-code=732167+Part.no+C (control figure)
Use and installation

The mounting rail is installed Cantilever arm 50 is installed Internal cantilever arm W17 and
between a cantilever arm and using a T-bolt. Adjustable cantilever arm W1840
wall to reduce surface pressure The arm is adjustable vertically. are mounted with T-bolt.
on porous walls or to enable The cantilever arm is vertically
vertical adjustment of cantilever adjustable.
arms.

Mounting rail WMS25


WEF-0001

Hot dip galv. Weight kg


Part. No. C* 100 pcs
Mounting rail WMS 25 725000 4 147
*EAN-code=732167+Part.no+C (control figure)
Use and installation

Mounting of cables with lashing The mounting rail is installed


wire, strips etc. directly onto wall.

84
Threaded rod M8 and M10 W76
WEF-0001
Used for installations of cable trays and lighting trunkings.
Joint nut M8 and M10 are used for joining of Threaded rods M8 and M10 W76.

Stainl. steel Electro-galv. Electro-galv.


L Electro-galv. (AISI316) White30 White80 Weight kg
mm Part. No. C* Part. No. C* Part. No. C* Part. No. C* 100 pcs
Threaded rod M8 500 725077 6 725078 3 16
Threaded rod M8 1000 725079 0 725080 6 32
Threaded rod M10 W76-2000 2000 716792 0 723925 2 729061 1 718795 9 100
Threaded rod M10 W76-3000 3000 716793 7 723926 9 729062 8 718797 3 150
Joint nut M8 725083 7 725084 4 5
Joint nut M10 724806 3 724807 0 7.2
*EAN-code=732167+Part.no+C (control figure)

Nut M8 and M10 are used with Threaded rod M8 and M10 W76.

Stainl. steel
Hot dip galv. (AISI316) Weight kg
Part. No. C* Part. No. C* 100 pcs
Nut M8 725085 1 725086 8 0.54
Nut M10 723938 2 723939 9 1.1
*EAN-code=732167+Part.no+C (control figure)

Use and installation

Use Joint nut M8 or M10 when The Threaded rod M10 W76 is Installation of Threaded rod M8
joining 2 pieces of Threaded rods cut to required length and or M10 W76 with Concrete screw
M8 or M10 W76. mounted with 2 Tube pendant MMS-I.
attachments W73.

85
Pendant attachment W21
WEF-0001
Mounted in Support bracket/joint W7 etc.

Plate Pre-galv. ZINKPOX®


thickness Pre-galv. Hot dip galv. White30 White80 Weight kg
mm Part. No. C* Part. No. C* Part. No. C* Part. No. C* 100 pcs
Pendant attachment W21 2 716630 5 734618 9 729054 3 783107 4 12
*EAN-code=732167+Part.no+C (control figure)
Use and installation

The Pendant attachment W21 The required length of Pendant For lighter installations with When mounting with wire, only
is inserted into the slits in the rail W32 is mounted in the small loads, only one half of the one half of the Pendant attach-
Support bracket/joint W7 (100- Pendant attachment W21 with Pendant attachment W21 is ment W21 is mounted in Support
400). Does not apply to W7-50, Screw set W37. mounted in Support bracket W7 bracket/joint W7 using Screw set
150, 500 and 600. Adjustable to ±30 mm. with Screw set W36/W36C. W36/W36C. The wire is mounted
The second part of the Pendant through the oval hole and locked
attachment W21 is used as a with a wire lock.
ceiling bracket. The Pendant rail
W32 is mounted using Screw set
W37.

When mounting cable tray or In concrete ceilings Pendant In metal plate ceilings, Pendant 1. Pendant attachment W21
Lighting trunking W70/W71, one attachment W21 is mounted with attachment W21 is mounted with 2. Screw set W36/W36C
half of Pendant attachment W21 Expansion bolt. Ogebe fixing type ED. Use 3. Support bracket/joint W7
is mounted directly in Support Screw set W36/W36C. 4. Cable tray/Lighting trunking
bracket/joint W7 with Screw set
W36/W36C. Pendant rail W32 is
mounted with Screw set W37.
Ceiling installation with cable tray/lighting trunking

W7 = Support bracket/joint
W21 = Pendant attachment
W31 = Ceiling attachment
W32 = Pendant rail
W36 = Screw set
W37 = Screw set
W73 = Tube pendant attachment
W76 = Pendant bolt M10

86
Tube pendant attachment W73
WEF-0001
Used for mounting of Pendant bolt M10 W76 in ceilings and trays.

Pre-galv. ZINKPOX®
Pre-galv. Hot dip galv. White30 White80 Weight kg
Part. No. C* Part. No. C* Part. No. C* Part. No. C* 100 pcs
Tube pendant attachment W73 716634 3 734621 9 729055 0 783117 3 7
*EAN-code=732167+Part.no+C (control figure)

Use and installation

The Tube pendant attachment The Tube pendant attachment Pendant bolt M10 W76 is easily Mounted in wood with self-drilling
W73 is mounted in Support can also be mounted directly in mounted in the spring clasp with- screws.
bracket/joint W7 with Screw set the lighting trunking using Screw out screws. Simple adjustment
W36/W36C. Does not apply to set W36/W36C. Does not apply up to ±30 mm.
W7-500 and 600. to Lighting trunking W70-40, Mounted in concrete ceilings with
where Pendant bracket W80 Expansion bolt.
must be used.

87
Pendant/Fixing rail 7L, 7
Used with Ceiling bracket 7 to form vertical pieces on site. End plug 7 must be used in Pendant/Fixing rail 7. WEF-0001
Pendant/Fixing rail 7L Pendant/Fixing rail 7 7L

L Pre-galvanized Hot dip galv. Weight kg


mm Part. No. C* Part. No. C* 100 pcs
Pendant/Fixing rail 7L 3020 735432 0 360
Pendant/Fixing rail 7 3020 734206 8 734205 1 370
* EAN-code=732167+part.no+C (control figure)
Use and installation

Using Ceiling bracket 7 together Cantilever arm 80 is infinitely Cantilever arm 80 can also be
with Pendant/Fixing rail 7L/7 adjustable along Pendant/Fixing mounted on both sides of the
makes it possible to produce rail 7L/7. Screw set 22S shall be Pendant/Fixing rail 7 at the same
vertical pieces in different lengths used when mounting. level (not 7L).
on site. Use 2 Screw sets 22S. End plug 7 must be used on Breaking load for symmetrical
Pendant/Fixing rail 7. loading 2500 kg (25 kN).

Ceiling bracket 7
To be used with Pendant/Fixing rail 7/7L to form vertical pieces on site. WEF-0001

11 x 18

Plate thickness Pre-galv. Hot dip galv. Weight kg


mm Part. No. C* Part. No. C* 100 pcs
Ceiling bracket 7 2.5 734331 7 734458 1 40
* EAN-code=732167+Part.no+C (control figure)
Use and installation

Using Ceiling bracket 7 together


with Pendant/Fixing rail 7/7L
makes it possible to produce
vertical pieces in different lengths
on site. Use 2 Screw sets 22S.
88
Vertical piece 7L, 7
WEF-0001
To be used together with Cantilever arm 80. The Cantilever arm is infinitely adjustable along the Vertical piece.
End plug 7 is mounted on Vertical piece 7 on delivery.

Vertical piece 7L Vertical piece 7

ZINKPOX®
L Hot dip galv. White80 Weight kg
mm Part. No. C* Part. No. C* 100 pcs
Vertical piece 7L-200 218 735207 4 780417 7** 46
Vertical piece 7L-300 290 735208 1 780418 4** 56
Vertical piece 7L-400 398 735209 8 780419 1** 69
Vertical piece 7L-500 506 735210 4 780420 7** 83
Vertical piece 7L-600 614 735211 1 780421 4** 98
Vertical piece 7L-700 722 735212 8 780422 1** 111
Vertical piece 7L-800 794 735213 5 780423 8** 120
Vertical piece 7L-900 902 735214 2 780424 5** 135
Vertical piece 7L-1000 1010 735215 9 780425 2** 148
Vertical piece 7L-1100 1118 735216 6 780426 9** 162
Vertical piece 7L-1200 1190 735217 3 780427 6** 171

Vertical piece 7-200 216 731871 1 738487 7** 60


Vertical piece 7-300 288 731872 8 738488 4** 70
Vertical piece 7-400 396 731873 5 738489 1** 80
Vertical piece 7-500 504 731874 2 738490 7** 100
Vertical piece 7-600 612 731875 9 738491 4** 110
Vertical piece 7-700 720 731876 6 738492 1** 120
Vertical piece 7-800 792 731877 3 738493 8** 130
Vertical piece 7-900 900 731878 0 738494 5** 150
Vertical piece 7-1000 1008 731879 7 738495 2** 170
Vertical piece 7-1100 1116 731880 3 738496 9** 180
Vertical piece 7-1200 1188 731881 0 738497 6** 190
Vertical piece 7-1300 1296 731882 7 738498 3** 200
Vertical piece 7-1400 1404 731883 4 738499 0** 220
Vertical piece 7-1500 1512 731884 1 738500 3** 230
Vertical piece 7-1600 1620 731885 8 738501 0** 250
* EAN-code=732167+Part.no+C (control figure) **Produced to order

89
Vertical piece 7L, 7
WEF-0001
Loading tables for Vertical piece 7L and 7

Vertical piece 7L Vertical piece 7

The bending moment M is the total sum of The bending moment M is the total sum of
F x A in kgcm. F x A in kgcm.
F = Force on cantilever arms in kg F = Force on cantilever arms in kg
F = Loading (kg/m) x Support distance (m) F = Loading (kg/m) x Support distance (m)
A = Distance between force and centerline A = Distance between force and centerline
vertical piece in cm vertical piece in cm
A = Width of ladder + 1.75 cm A = Width of ladder + 3.5 cm
2 2
Use and installation

Cantilever arm 80 is infinitely Cantilever arm 80 is infinitely Cantilever arm 80 can also be
adjustable along Vertical piece adjustable along Vertical piece 7. mounted on both sides of the
7L. Screw set 22S must be used Screw set 22S must be used Vertical piece 7 at the same level
when mounting. The cantilever when mounting. End plug 7 must (not 7L).
arm must always be mounted in be used on Vertical piece 7. Breaking load for symmetrical
the same direction as the ceiling loading 2500 kg (25 kN).
bracket.

End plug 7
For Vertical piece 7 or Pendant/Fixing rail 7. WEF-0014

Polyamide (PA) Red Weight kg


Part. No. C* 100 pcs
End plug 7 730178 2 1.5
*EAN-code=732167+Part.no+C (control figure)
Use and installations

End plug 7 must always be used


at the cut end of Vertical piece 7
or Pendant/-Fixing rail 7.
90
U

Pendant/Fixing rail 24/34


WEF-0001
For mounting together with Ceiling bracket 5 to provide vertical pieces.

ZINKPOX®
L Pre-galv Hot dip galv White80 Weight kg
mm Part. No. C* Part. No. C* Part. No. C* 100 pcs
Pendant/Fixing rail 24/34 292.5 725357 9 23
Pendant/Fixing rail 24/34 382.5 725358 6 31
Pendant/Fixing rail 24/34 495 725359 3 40
Pendant/Fixing rail 24/34 697.5 725360 9 56
Pendant/Fixing rail 24/34 990 725361 6 80
Pendant/Fixing rail 24/34 2970 721102 5 715879 9 716309 0 240
*Ean-code=732167+Part.no+C (control figure)

Use and installation

MAX 20 o

1 Pendant/Fixing rail 24/34, Side mounting of pendant/fixing


1 Ceiling bracket 5 and 1 Screw rails may be done using
set 22S together provide a 2 Expansion bolts.
vertical piece that can be
mounted with up to 20º slope.

91
End plug 28C,D,E and F
WEF-0003
Used for mounting in pendant ends to provide protection against personal injury.

Orange plastic Weight kg


Part. No. C* 100 pcs
End plug 28C 789875 6 0.5
End plug 28D 709020 4 1
End plug 28E 709021 1 0.5
End plug 28F 789876 3 4
* EAN-code=732167+Part.no+C (control figure)

Use and installation

End plug 28C fits Vertical piece 2 End plug 28F fits Vertical piece
and Pendant/ Fixing rail 24/34. 20FS and Pendant/ Fixing rail
End plug 28E fits Vertical piece 24/20FS.
2F and Pendant/ Fixing rail 24/48. End plug 28D fits Vertical piece 20
and Pendant/ Fixing rail 24/20.

92
Ceiling bracket 5
WEF-0001
Can be used together with Pendant/Fixing rail 24/34.

ZINKPOX®
Pre-galv. Hot dip galv. White80 Weight kg
Part. No. C* Part. No. C* Part. No. C* 100 pcs
Ceiling bracket 5 721101 2 718640 2 716293 2 35
*EAN-code=732167+Part.no+C (control figure)

Use and installation

Max 20°

1 Pendant/Fixing rail 24/34, 1 Ceiling bracket 5 is installed


Ceiling bracket 5 and 1 Screw against the back of the pendant
set 22S together provide a verti- rail by turning the bracket 90º
cal piece that can be mounted and by pushing the lip into the
with up to 20º slope. hole of the rail.
Breaking load for rail 24/34 Next the bracket is turned back
=1000 kg (10 kN). again and fastened in the desired
Breaking load for rail 24/48 position with 1 Screw set 22S.
= 1200 kg (12 kN). When installing against a hori-
zontal ceiling the bolt must be
locked in the recess of the slot
for better stability sideways.

93
Bracket 60/40
WEF-0001
Bracket 60/40 is installed together with Pendant/Fixing rail 24/34 to reduce the deflection of long pendants.

ZINKPOX®
Hot dip galv. White80 Weight kg
Part. No. C* Part. No. C* 100 pcs
Bracket 60/40 718904 5 720531 8 10
*EAN-code=732167+Part.no+C (control figure)

Use and installation

Use Bracket 60/40 with Pendant/Fixing rail 24/34 to reduce the


deflection of long pendants. Cut the pendant/fixing rail to a suitable
length on site.

94
Pendant bar 1
WEF-0001
Installed in order to reduce the deflection of long Vertical pieces 2F and 20.
A A

B
B

Pendant bar 1/300-800 Pendant bar 1-1500

ZINKPOX®
A B Hot dip galv. White80 Weight kg
mm mm Part. No. C* Part. No. C* 100 pcs
Pendant bar 1-300 80 300 717640 3 717643 4** 50
Pendant bar 1-500 130 500 717641 0 717644 1** 80
Pendant bar 1-800 215 800 717642 7 717645 8** 125
Pendant bar 1-1500 May vary 718903 8 720530 1** 560
*EAN-code=732167+Part.no+C (control figure) **Produced to order

Use and installation

In order to reduce deflection of Vertical piece 2F for heavy loads on


Internal cantilever arm W17/40 and Cantilever arm 50/50L, Pendant
bar 1 is installed with T-bolt. Loadings in accordance with table
below.

Loading table for Cantilever arm W17/40


Max. loading F at 3˚ deflection of cantilever arm
Cantilever arm 2F-280 2F-370 2F-505 2F-730 2F-1000
type kN kg kN kg kN kg kN kg kN kg
Without bar W17/40-100 0.65 65 0.65 65 0.60 60 0.55 55 0.55 55
200 0.60 60 0.60 60 0.50 50 0.50 50 0.45 45
300 0.70 70 0.70 70 0.70 70 0.65 65 0.55 55
400 0.55 55 0.55 55 0.55 55 0.50 50 0.45 45
With bar 1-300 W17/40-100 0.75 75 0.70 70 0.65 65
200 0.60 60 0.55 55 0.50 50
300 0.80 80 0.75 75 0.70 70
400 0.70 70 0.65 65 0.50 50
With bar 1-500 W17/40-100 0.90 90 0.70 70
200 0.70 70 0.60 60
300 0.95 95 0.80 80
400 0.70 70 0.55 55
With bar 1-800 W17/40-100 0.80 80
200 0.60 60
300 0.85 85
400 0.65 65

95
Pendant strip W33
WEF-0001
The Pendant strip W33 is delivered in straight 1 m lengths and bent on site.

Pre-galv.
Pre-galv. White30 Weight kg
Part. No. C* Part. No. C* 100 pcs
Pendant strip W33 721786 1 729059 8 19
*EAN-code=732167+Part.no+C (control figure)
Use and installation

The Pendant strip W33 is If an adjustment of pendant Mounted in open intersections


delivered straight. Can be bent length is required this can be for ceiling installation. Mounted
on site. Pendants longer than achieved by cutting the strip in with Screw set W36/W36C in
1 m are joined by overlapping the middle and overlapping the Support bracket/joint W7.
using Screw set W36/W36C. two parts so that a joint can be
achieved using Screw set W36/
W36C.

96
Pendant rail W32
WEF-0001
Pendant rail W32 can be installed in ceilings together with Ceiling attachment W31 or Ogebe fixing type E.

Pre-galv. ZINKPOX®
Pre-galv Hot dip galv White30 White80 Weight kg
Part. No. C* Part. No. C* Part. No. C* Part. No. C* 100 pcs
Pendant rail W32 716798 2 734620 2 729058 1 783122 7 180
*EAN-code=732167+Part.no+C (control figure)
Use and installation

The Pendant rail W32 is cut to For lighter installations with The Pendant rail W32 can be Using Locking clamp W77, the
the required length and mounted small loads, only one half of joined by placing overlapping Pendant rail W32 can be
in the ceiling with Ceiling attach- the Pendant attachment W21 is and assembly using Screw set mounted between two lighting
ment W31 and Pendant attach- mounted in Support bracket W7 W37 trunkings or cable trays either as
ment W21 mounted onto Support with Screw set W36/W36C. a stabiliser or to form a simple
bracket/joint W7. The second part of the Pendant dukt.
attachment W21 is used as a
ceiling bracket. The Pendant rail
W32 is mounted using Screw set
W37.

97
Ceiling attachment W31
Ceiling attachment W31 for Pendant rail W32. WEF-0001

Plate Pre-galv. ZINKPOX®


thickness Pre-galv. Hot dip galv. White30 White80 Weight kg
mm Part. No. C* Part. No. C* Part. No. C* Part. No. C* 100 pcs
Ceiling attachment W31 2 716816 3 734619 6 729063 5 783120 3 6.5
*EAN-code=732167+Part.no+C (control figure)
Use and installation

The Ceiling attachment W31 is The Ceiling attachment W31 can The Ceiling attachment W31 The Ceiling attachment W31 can
mounted in concrete ceilings with be mounted directly in a slanted can be mounted directly in TP be mounted onto a concrete
one or two Expansion bolts. ceiling with 2 Expansion bolts. ceilings using an Ogebe fixing beam with Expansion bolts.
Pendant rail W32 is mounted type E.
with Screw set W37.
The Ceiling attachment W31 can
be rotated 90˚.

Locking clamp W77


Mounted to lock Pendant rail W32 when installed between lighting trunking or cable trays as a stabilizer. WEF-0001

Plate Pre-galv.
thickness Pre-galv. White30 Weight kg
mm Part. No. C* Part. No. C* 100 pcs
Locking clamp W77 1.25 716797 5 729060 4 1.5
*EAN-code=732167+Part.no+C (control figure)
Use and installation

Pendant rail W32 mounted with Locking clamp W77 used when Pendant rail W32 is mounted Locking clamp W77 fixed to the
Screw set W36/W36C or W34. between two Lighting trunking W70/W71 or cable trays as a stabi- fold of trunking/tray with a pair of
lizer. pliers.
98
Fixing rail 24/26x53, casting-in
For casting-in in walls and ceilings. WEF-0001

Transverse force Hot dip galv. Weight kg


lx Wx ly Wy Part. No. C* 100 pcs
Fixing rail 24/26x53 for casting-in 10.39 cm4 3.92 cm 3 2.78 cm4 1.90 cm3 768063 4 970
* EAN-code=732167+Part.no+C (control figure)
Use and installation

Fixing rail 24/26 x 53 for casting- Max. pull-out load:


in in walls and ceilings. Mount 1000 kg/0.5 m of casting-in fixing
cantilever arms with T-bolt 26F. rail (Concrete class K200).

99
Vertical piece 2FPK
For installations in ceilings close to wall. WEF-0001

ZINKPOX®
L Hot dip galv. White80 Weight kg
mm Part. No. C* Part. No. C* 100 pcs
Vertical piece 2FPK-300 280 788655 5 788660 9** 120
Vertical piece 2FPK-500 500 788656 2 788661 6** 155
Vertical piece 2FPK-750 730 788657 9 788662 3** 205
Vertical piece 2FPK-1000 1000 788658 6 788663 0** 250
* EAN-code=732167+Part.no+C (control figure) **Produced to order
Loadings

Vertical piece 2FPK mounted in Vertical piece 2FPK mounted in Deflection of Vertical piece 2FPK
the inner hole. the outer hole. is reduced by installing Pendant
Breaking load=1400 kg Breaking load=200 kg bar 1. Loadings in accordance
(14 kN) at symmetrical loading. (2kN) at symmetrical loading. with table below.
Max permitted load F at max permitted deflection 1/20 of the length L of the cantilever arm in accordance to standard IEC 61537.
Cantilever arm 2FPK-300 2FPK-500 2FPK-750 2FPK-1000
kg kg kg kg
Without 50-200 L=250 140 130 100 80
Pendant bar 1 50-400 L=450 145 135 95 75
50-600 L=650 105 100 80 60
With 50-200 L=250 155 125
Pendant bar 1/500 50-400 L=450 165 120
50-600 L=650 115 90
Use and installation

Vertical piece 2FPK can be Vertical piece 2FPK is suitable


mounted in ceiling close to wall. for floor mounting.

100
Vertical piece 2
WEF-0001
To be used for installation of centre pendant of Cable trays W1 and W3, mesh trays and lighting trunking.

ZINKPOX®
L Hot dip galv. White80 Weight kg
mm Part. No. C* Part. No. C* 100 pcs
Vertical piece 2-300 279 717191 0 716283 3 52
Vertical piece 2-400 392 717192 7 716284 0 62
Vertical piece 2-500 504 717193 4 716285 7 72
Vertical piece 2-700 729 717194 1 716286 4 93
Vertical piece 2-1000 1022 717195 8 716287 1 120
*EAN-code=732167+Part.no+C (control figure)
Use and installation

Mount Vertical piece 2 using an Mount Vertical piece 2 on Fixing Vertical piece 2 may be joined to
Expansion bolt alt. Concrete rail 24/26x53 for casting-in using achieve the required length using
screw. T-bolt. Pendant/Fixing rail 24/34 and
Pendant joint 2J.

Support bracket W1940/W1960 Support bracket W1940/1960 Use Pendant joint 2J to join two
can be mounted on Vertical piece mounted in the fixing plate of the Vertical pieces 2.
2 with Angle bracket W8S. vertical piece with Screw set
Use Screw set W36/W36C. W36/W36C.

101
Vertical piece 2F
WEF-0001
Used for installation of Internal cantilever arm W17/40,
Adjustable cantilever arm W1840/W1860 or Cantilever arm 50.

ZINKPOX®
L Hot dip galv. White80 Weight kg
mm Part. No. C* Part. No. C* 100 pcs
Vertical piece 2F-280 280 717196 5 717201 6 80
Vertical piece 2F-370 370 717197 2 717202 3 100
Vertical piece 2F-505 505 717198 9 717203 0 130
Vertical piece 2F-730 730 717199 6 717204 7 170
Vertical piece 2F-1000 1000 717200 9 717205 4 220
Vertical piece 2F-1500 1495 787276 3 787277 0 290
*EAN-code=732167+Part.no+C (control figure)
Use and installation

Mounted in ceiling with Expan- Cantilever arm 50 is mounted Internal cantilever arm W17/40 is In order to reduce the deflection
sion bolt alt. Concrete screw. with a T-bolt. mounted with a T-bolt. of Vertical piece 2F for heavy
loads on Internal cantilever arm
W17/40 and Adjustable cantile-
ver arm W1840/W1860, Pen-
dant bar 1 is installed.

102
Vertical piece 20
WEF-0001
Used for vertical installation with cantilever arms from a ceiling or on a floor.

ZINKPOX®
L Hot dip galv. White80 Weight kg
mm Part. No. C* Part. No. C* 100 pcs
Vertical piece 20-505 505 715723 5 716276 5 250
Vertical piece 20-730 730 715724 2 716277 2 330
Vertical piece 20-1000 1000 715725 9 716278 9 440
Vertical piece 20-1500 1495 715726 6 716279 6 620
Vertical piece 20-2000 1990 715727 3 716280 2 800
Vertical piece 20-3000 2980 715728 0 716281 9 1180
*EAN-code=732167+Part.no+C (control figure)
Use and installation

Mounted in ceiling with Expan- Internal cantilever arm W17/40 is On Vertical piece 20, mount Can- Vertical piece 20 may be
sion bolt alt. Concrete screw. mounted with a T-bolt. tilever arm 50 using a T-bolt. equipped with a protective
orange coloured End plug 28D.

103
End bracket WN17
WEF-0001
Used as vertical piece, for example mounted on Support bracket/joint W7 to achieve an invisible suspension.

Pre-galv.
Pre-galv. Hot dip galv. White80 Weight kg
Part. No. C* Part. No. C* Part. No. C* 100 pcs
End bracket WN17 733090 4 733091 1 733092 8 10
*EAN-code=732167+Part.no+C (control figure)

Use and installation

End bracket WN17 can


be mounted as vertical piece on
Support bracket/joint W7, use
Screw set W36/W36C.
The end brackets are joined with
2 Screw sets 22S.
Max symmetrical load on the end
bracket is 100 kg at a tightening
torque of 10.4 Nm.

104
Angle bracket W8
WEF-0001
The angle bracket is mounted in the tray horizontally to a wall or vertically to a floor.
The angle bracket can also be mounted as a pendant bracket in the lighting trunking.
It can also be used as stabilizing angle.

Pre-galv. ZINKPOX®
Pre-galv. Hot dip galv. White30 White80 Weight kg
Part. No. C* Part. No. C* Part. No. C* Part. No. C* 100 pcs
Angle bracket W8 716821 7 728883 0 729066 6 783124 1 6
*EAN-code=732167+Part.no+C (control figure)

Use and installation

2 Angle brackets W8 are Angle bracket W8 mounted in The Angle bracket W8 is Angle bracket mounted in bottom
mounted in Cable trays W1/40 or bottom of lighting trunking with mounted to achieve clearance of lighting trunking with Screw
W3/40 using 2 Screw sets W38P Screw set W36/W36C. from wall or where there is a set W36/W36C as pendant
for horizontal connection to wall Expansion bolts are used for large asymmetric load on the tray attachment.
and vertical connection to floor. installation in concrete walls. at pendant installation. Mounted
Can be mounted with legs In sheet metal walls mounting is at a distance of 1.5-2 m.
pointing inwards or outwards. achieved with an Ogebe fixing
type ED.

Horizontal installation of Cable Horizontal installation of Cable


tray W3/W1 on floor or vertically tray W3 on floor or vertically on
on wall. wall.
The angle bracket W8 can be The angle bracket W8 can be
turned to reduce the distance to turned to reduce the distance to
floor or wall. floor or wall.

105
Angle bracket W8S
WEF-0001
To be used for various installations of Pendant/Fixing rail 24/34, support brackets etc.

Pre-galv. ZINKPOX®
Pre-galv. Hot dip galv. White80 White80 Weight kg
Part. No. C* Part. No. C* Part. No. C* Part. No. C* 100 pcs
Angle bracket W8S 728071 1 726873 3 726874 0 783126 5 8
*EAN-code=732167+Part.no+C (control figure)

Use and installation

Vertical piece 2 or Pendant/ Support bracket 3 can be Support bracket W1940/ W1960 Support bracket W1940/ W1960
Fixing rail 24/34 can be mounted mounted in ceilings with Angle can be mounted on Ceiling can be mounted on Vertical piece
with Angle bracket W8S directly bracket W8S and Screw set 22S. bracket 5 with Angle bracket 2 with Angle bracket W8S and
into the lighting trunking. W8S and Screw set 22S. Screw set 22S.
Use Screw set 22S.

Clamp suspension of cable tray Angle bracket W8S can be used Support bracket/joint W7 can be
can be made with Pendant/Fix- for installations in Pendant/Fixing mounted directly on Vertical
ing rail 24/34, Angle bracket W8S rail 24/34. Use Screw set piece 2 with Angle bracket W8S
and Screw set 22S. 22S. An easy way to build stands and Screw set 22S.
for electrical cabinets. Does not apply to widths used for
joining only.

106
Fixing tray N for casting-in
WEF-0001
Pieces of Polystyrene at both ends makes it possible to adjust the height of the tray.

A Pre-galv. Weight kg
mm Part. No. C* 100 pcs
Fixing tray N-300 for casting-in 330 782695 7 1800
Fixing tray N-400 for casting-in 430 782696 4 2200
*EAN-code=732167+Part.no+C (control figure)
Use and installation

Fixing tray N for casting-in Fixing tray N adjusted onto the The length is adjustable to ceiling The mesh tray mounted into the
mounted in the mould. mould (from out- or inside). and floor by moving the pieces of Fixing tray N is used for
Polystyrene, total height min mounting of cables.
2400-max 3000 mm.

107
Lashing wire
WEF-0011
For lashing of wires in mesh trays.

Diam Breaking load Weight kg


mm kg Part. No. C* 100 m
HTR-2303 Lashing wire, stainless steel, white PVC 1.25 92 713686 5 1.3
HTR-2313 Lashing wire, stainless steel, black PVC 1.25 92 713687 2 1.3
HT-2304 Lashing wire, white PVC 1.5 25 713684 1 1.8
HT-2314 Lashing wire, black PVC 1.5 25 713685 8 1.8
*EAN-code=732167+Part.no+C (control figure)
Use and installation

Lashing wire is used for


mounting in mesh trays.

Ceiling mesh tray WN2


WEF-0001
For installation in ceilings. Wire Ø4.4 mm.

2000
B

Stainl. steel Electro-galv.


Electro-galv. Hot dip galv. (AISI316) White80 Weight kg
A B Part. No. C* Part. No. C* Part. No. C* Part. No. C* 100 pcs
Ceiling mesh tray WN2 100 60 727991 3 727992 0 727993 7 727994 4 100
*EAN-code=732167+Part.no+C (control figure)
Use and installation

Mounted in ceilings with Mounted under desks with


Ceiling bracket WN16. Ceiling bracket WN16.

108
Ceiling bracket WN16
For installation of Ceiling mesh tray WN2. WEF-0001

Stainl. steel Electro-galv.


Electro-galv. Hot dip galv. (AISI316) White80 Weight kg
Part. No. C* Part. No. C* Part. No. C* Part. No. C* 100 pcs
Ceiling bracket WN16 727995 1 727996 8 727997 5 727998 2 5
*EAN-code=732167+Part.no+C (control figure)
Use and installation

Ceiling mesh tray WN2 must be Ceiling mesh tray WN2 mounted
mounted with Ceiling bracket under desks with Ceiling bracket
WN16. WN16.

Earth clamp W79


Suitable for mounting on Junction box plate W24. Used for protective earthing. WEF-0001

Electro-galv. Weight kg
Part. No. C* 100 st
Earth clamp W79 716640 4 0.2
*EAN-code=732167+Part.no+C (control figure)
Use and installation

Earth clamps W79 are intended for use when the earthing of
mounting plates for the installation of machines complying with
regulations for use of high tension current is required.
The junction box plate’s (mounting plate’s) oval holes facilitate the
moving of the Earth clamp W79 so that it is always located under the
machine casing.
If the machine’s earth clamp is not approved for splicing of earth
cable, this must pass in unbroken state through the machine’s earth
clamp to the earth clamp in the junction box plate.
Wibe Junction box plate W24 and Earth clamp W79 are approved by
the National Electrical Inspectorate 850513 in accordance with
annotation S24-138/85.
109
Cover plate W16
WEF-0001
Mounted with Screw set W36/W36C under 90˚ bends, T- and X-junction
if one needs to level out differences in levels between tray and junction.

Plate Pre-galv.
A thickness Pre-galv. White30 Weight kg
mm mm Part. No. C* Part. No. C* 100 pcs
Cover plate W16-70 70 1.5 718036 3 729154 0 6
Cover plate W16-100 100 1.5 718037 0 729155 7 12
Cover plate W16-200 200 1.5 718038 7 729156 4 48
Cover plate W16-300 300 1.5 718039 4 729157 1 108
Cover plate W16-400 400 1.5 718040 0 729158 8 192
*EAN-code=732167+Part.no+C (control figure)
Use and installation

Mounted with Screw set W36/


W36C under X-junction W13/40 if
one needs to level out differences
in height between tray and bend.

110
Dividing strip 39
WEF-0001
Mounted to divide a cable tray or lighting trunking into two or more channels in order to
separate different types of cables and pipes. Mounted with Support band W6.

Plate Pre-galv. Pre-galv.


thickness H Pre-galv. White30 White80 Weight kg
mm mm Part. No. C* Part. No. C* Part. No. C* 100 pcs
Dividing strip 39/24 0.6 24 718835 2 717950 3 46
Dividing strip 39/55 0.6 55 725785 0 782787 9 725786 7 73

Plate Stainl. steel


thickness H Hot dip galv. (AISI316L) Weight kg
mm Part. No. C* Part. No. C* 100 pcs
Dividing strip 39/24 0.6 24 731747 9 725593 1 46
Dividing strip 39/55 0.6 55 732983 0 725594 8 73
*EAN-code=732167+Part.nr+C (control figure)

Use and installation

Used to separate tray or trunking in two or more ducts thereby


separating control cables from other cables and pipes. The hole
structure at distances of 250 mm permits two fixing opportunities
with Support bands W6 even after cutting.

111
Insert piece W39
WEF-0021
Insert piece W39 is used to join Dividing strips W39.

Plastic Weight kg
Part. No. C* 100 pcs
Insert piece W39 716824 8 3
*EAN-code=732167+Part.no+C (control figure)
Use and installation

Insert piece W39 is used to join Dividing strips W39 and is mounted
on Support bracket/joint W7 or Internal cantilever arm W17/40.
When mounting over Internal cantilever arm W17/40, break away
plastic bit from component.

Support band W6
WEF-0001
The Support band W6 is mounted to fix the lateral position of one or several Dividing strips 39.

L Pre-galv. Weight kg
mm Part. No. C* 100 pcs
Support band W6-70 67 718828 4 1.0
Support band W6-100 97 718829 1 1.4
Support band W6-200 197 718830 7 2.8
Support band W6-300 297 718831 4 4.3
Support band W6-400 397 718832 1 5.7
Support band W6-500 497 718833 8 7.2
Support band W6-600 597 718834 5 8.6
*EAN-code=732167+Part.no+C (control figure)
Use and installation

Support band W6 is mounted to fix one or more Dividing strips 39 lat-


erally. The holes in the support band and the locking pins in Dividing
strip 39 allow for a fixed division with intervals of 25 mm.
112
Tele-conduit 36
WEF-0001
With knock-out holes
Tele-conduit is installed where a separate tray is required for low-tension cables.

Pre-galv.
B C Pre-galv. Hot dip galv. White80 Weight kg
mm mm Part. No. C* Part. No. C* Part. No. C* 100 pcs
Tele-conduit 36-50 42 50 725065 3 731748 6 725068 4 94
Tele-conduit 36-100 92 100 725066 0 731749 3 725069 1 142
Tele-conduit 36-200 192 200 725067 7 731750 9 725070 7 238
*EAN-code=732167+Part.no+C (control figure)

Use and installation

Make a hole for cable passage


by pushing out the washer from
below with a screw driver or
similar.

113
Cover W5
WEF-0001
Length 2000 mm. The cover is used for screening control cables and in dusty and dirty premises.

Pre-galv.
t B Pre-galv. White30 Weight kg
mm mm Part. No. C* Part. No. C* 100 pcs
Cover W5-60 0.7 61 732213 8 734133 7 90
Cover W5-70 0.7 71 732214 5 729015 4 100
Cover W5-100 0.7 101 732215 2 729016 1 140
Cover W5-150 0.7 151 732216 9 733134 5 190
Cover W5-200 0.7 201 732217 6 729017 8 250
Cover W5-300 0.7 301 732218 3 729018 5 360
Cover W5-400 1.0 401 732219 0 729019 2 680
Cover W5-500 1.0 501 732220 6 729020 8 840
Cover W5-600 0.7 601 732221 3 729021 5 700

ZINKPOX®
t B Hot dip galv. White80 Weight kg
mm mm Part. No. C* Part. No. C* 100 pcs
Cover W5-60 1.0 61 732261 9 782362 8 140
Cover W5-70 1.0 71 732262 6 782363 5 160
Cover W5-100 1.0 101 732263 3 782364 2 210
Cover W5-150 1.0 151 732264 0 782365 9 290
Cover W5-200 1.0 201 732265 7 782366 6 370
Cover W5-300 1.0 301 732266 4 782367 3 540
Cover W5-400 1.0 401 732267 1 782368 0 710
Cover W5-500 1.0 501 732268 8 782369 7 880
Cover W5-600 1.0 601 732269 5 782370 3 1050
*EAN-code=732167+Part.no+C (control figure)

Use and installation

Used for screening of control Covers must be mounted on cable


cables and in dusty and dirty trays with Cover clamp W62.
premises.

114
Cover clamp W62
WEF-0001
Used for fixing covers on Trays W1 and W3 as well as on Lighting trunking W70/W71.

Stainl. steel
(AISI304) Weight kg
Part. No. C* 100 pcs
Cover clamp W62 730186 7 0.8
*EAN-code=732167+Part.no+C (control figure)

Use and installation

Cover clamp W62 used for Start by pressing the Cover


fixing the covers on Cable tray clamp W62 over the sides of the
W1 and W3 as well as on cover. Then snap the cover over
Lighting trunkings W70 and W71. the folded edges of the tray.
6 Cover clamps W62 are needed
per cover.

115
Combi bracket 53
Used for mounting cable trays, mesh trays and cable ladders on seemed roofing sheet etc. WEF-0001,-0031

Hot dip galv. Plastic Weight kg


Part. No. C* Part. No. C* 100 pcs
Combi bracket 53 782353 6 26
Insulating plate 54 787223 7 2
*EAN-code=732167+Part.no+C (control figure)
Breaking load*
Type of roofing sheet Insulating plate Permitted load

Bandsheet Prelac No F1=100 kg


Copper sheeting Yes F2=50 kg
Bandsheet Prelac No F3=100 kg
Copper sheeting Yes F4=50 kg

* Loading values and fixing of roof sheet - follow the supplier´s recommendations
Test have been made of:
Bandsheet Prelaq BLX t=0.6 SSAB tunnplåt
Copper sheeting annealed SS 5015-80 t=0.6
Tightening torque at test=60Nm
Use and installation

Combi bracket 53 mounted on Alternative mounting of Combi In order to avoid contact between Alternative mounting of Combi
seamed roofing sheet. bracket 53. Combi bracket 53 and copper bracket 53 and Insulating plate
sheeting, Insulating plate 54 54.
must be used.

Cable ladder mounted across the Cable ladder mounted along the Mesh tray mounted along the Mesh tray mounted across the
seams of the roofing sheets with seams of the roofing sheets with seams of the roofing sheets seams of the roofing sheets
Combi bracket 53, Wall bracket Combi bracket 53, Wall bracket with Combi bracket 53 and with Combi bracket 53 and
11/25 and Screw set 22S. 11/25, Screw set 22S, Pendant/ accessories from the Mesh tray accessories from the Mesh tray
Fixing rail 24/48 and T-bolt 26F. program. program.

116
Strip fixing W44
WEF-0022
The Strip fixing W44 enables strapping of cables in an unperforated tray.

Plastic (black) Weight kg


Part. No. C* 100 pcs
Strip fixing W44 718469 9 1.0
*EAN-code=732167+Part.no+C(control figure)
Use and installation

The Strip fixing W44 is provided with double sided adhesive tape and is attached to the tray bottom.
Alternatively, blind rivets or self-tapping screws can be used.
When mounting with double sided adhesive tape, the surface on the tray bottom must be wiped clean.
Loads may not be applied until after 24 hours. Full adhesion is obtained after 72 hours in 21˚C. Ideal
application temperature is 21˚-38˚C. Application below normal room temperature is not recommended.
Each Strip fixing W44 can be split up in 2 to 6 pieces. Supplied with 50 pieces in a plastic bag.

Protection strip W48


Used to protect the cables from damage. WEF-0030

Plastic Weight kg
Part. No. C* 100 pcs
Protection strip W48 787211 4 6.1
*EAN-code=732167+Part.no+C (control figure)
Use and installation

When cutting a cable tray you can


mount Protection strip W48 to
protect the cables from damage.

117
Luminaire bracket W50
For mounting light fittings between two parallel Cable trays W1/W3 or Lighting trunking W70/W71. WEF-0001
Dimension H is specified when ordering.

Plate Pre-galv.
H thickness Pre-galv White80 Weight kg
mm mm Part. No. C* Part. No. C* 100 pcs
Luminaire bracket W50 ** 2.5 720520 2 720785 5 25***
*EAN-code=732167+Part.no+C (control figure)
**Selected with respect to height of the light fittings
***H=100 mm
Use and installation

Repair paint
Galvafroid for repair of damaged places on pre-galvanized or hot dip galvanized cable trays and accessories. WEF-0013, 0016
Repair paint for minor damages of powder coated products.

Volume Weight kg
l Part. No. C* 100 pcs
Anti-corrosive paint "Galvafroid", tin 0.3 717637 3 86
Repair paint White RAL 9003 Gloss 30, spray bottle 0.4 739713 6 60
Repair paint White RAL 9010 Gloss 80, spray bottle 0.4 728027 8 60
*EAN-code=732167+Part.no+C (control figure)
Use and installation

Galvafroid used to increase the


protection of cut or damaged Repair paint in spray bottle
places.Applied with a colour for repainting of minor paint
brush. damages.

118
Screw set 22S
For mounting of Ceiling bracket 5 on Pendant/Fixing rail 24/34 and WEF-0001
Cantilever arm 80 on Vertical piece 7 or Wall bracket 80 etc.

Stainl. steel
Hot dip galv. (AISI316) Weight kg
Part. No. C* Part. No. C* 100 pcs
Screw set 22S (bolt MVBF8x16+nut M6MF8) 713694 0 725582 5 1.9
*EAN-code=732167+Part.no+C (control figure)

Spring nut M8
For permanent mounting of fittings (instrument cabinets etc.) on Pendant/Fixing rail 24/48. WEF-0001

Hot dip galv. Weight kg


Part. No. C* 100 pcs
Spring nut M8 716407 3 2.7
*EAN-code=732167+Part.no+C (control figure)

Mounting set W78


For mounting of Threaded rod M10 W76 in plate or light concrete ceilings. WEF-0001

Hot dip galv. Weight kg


Part. No. C* 100 pcs
Mounting set W78 (washer diam.50+nut M6M10) 717069 2 5.5
*EAN-code=732167+Part.no+C (control figure)

Screw set W36


For mounting of pendant attachments in Support bracket/Joint W7. WEF-0001

Stainl. steel
Electro-galv. (AISI316) Weight kg
Part. No. C* Part. No. C* 100 pcs
Screw set W36 (bolt MVBF8x16+nut M6MF8) 715646 7 725581 8 1.2
*EAN-code=732167+Part.no+C (control figure)

Screw set W36C


Slotted screw used for mounting of pendant attachments in Support bracket/joint W7. WEF-0001

Electro-galv. Weight kg
Part. No. C* 100 pcs
Screw set W36C (Slotted screw M8x16+nut M6MF 8 toothed) 783500 3 1.8
*EAN-code=732167+Part.no+C (control figure)

119
Screw set W37
For assembly of Pendant attachment W21 and Ceiling attachment W31 with Pendant rail W32. WEF-0001
For joining of Pendant rail W32.

Stainl. steel
Electro-galv. (AISI316) Weight kg
Part. No. C* Part. No. C* 100 pcs
Screw set W37 (bolt MVBF 8x35+nut M6MF 8) 716799 9 725586 3 2.8
*EAN-code=732167+Part.no+C (control figure)

Screw set W38P


Used for mounting of joints, bends, junctions, Shade ledge W26 and Integrated ceiling support channel W27. WEF-0001
Screw set W38P pierces through lacquered surfaces securing potential balancing.
N. B. The joints must be unlacquered. Patented.

Electro-galv.
Electro-galv. Dacromet White60** Weight kg
Part. No. C* Part. No. C* Part. No. C* 100 pcs
Screw set W38P 735177 0 733258 8 782216 4 0.4
*Ean-code=732167+Part.no+C (control figure) **White laquered screw head

Screw set W34


For mounting Tray W3 on Cantilever arm 50. WEF-0001
For mounting Junction box plate W24 in Tray W3, Lighting trunking W70 and W71.
For mounting Locking clamp W77 or Angle bracket W8 onto Pendant rail W32.
For assembly of Angle bracket W8 (light fitting bracket).
For joining of Installation Trays W4 and installations with Profile W-swing 2.

Stainl. steel
Dacromet Electro-galv. (AISI316) Weight kg
Part. No. C* Part. No. C* Part. No. C* 100 st
Screw set W34 (bolt MSCS 6x12+nut M6MF6) 734646 2 718473 6 725589 4 0.8
*EAN-code=732167+Part.nr+C (control figure)

Screw W40
For locking of T-joint W29 in open junctions. WEF-0001

Electro-galv Weight kg
Part. No. C* 100 pcs
Screw W40 (screw RXS ST 5.5x13-H) 721868 4 0.3
*EAN-code=732167+Part.no+C (control figure)

Locking plug W41


For quick locking of joints, bends and branches in cable trays and lighting trunking. WEF-0004

Plastic Weight kg
Part. No. C* 100 pcs
Locking plug W41 718645 7 0.1
*EAN-code=732167+Part.no+C (control figure)
120
T-bolt 26F
WEF-0002
Used for mounting with Pendant/Fixing rails.

A
L

T-bolt 26F/M8
T-bolt 26F/M10
(For P/F-rail 24/48)

Stainl. steel
D L A Electro-galv. Hot dip galv. (AISI316) Weight kg
mm mm Part. No. C* Part. No. C* Part. No. C* 100 pcs
T-bolt 26F M8 30 24 734983 8 734744 5 734986 9 4.5
T-bolt 26F M10 30 24 734864 0 716794 4 728596 9 7
T-bolt 26F M8 40 34 734984 5 734745 2 734987 6 5
T-bolt 26F M10 40 34 734865 7 716795 1 728597 6 7.5
T-bolt 26F M8 50 44 734985 2 734746 9 734988 3 5.5
T-bolt 26F M10 50 44 734866 4 716796 8 728598 3 8
*EAN-code=732167+Part.no+C (control figure)

Max permitted extraction force


T-bolt 26F M8/M10 + P/F-rail 24/48 +Washer 8,4x19x1,5

T-bolt 26F M8 + P/F-rail 24/48 + Washer 9x35x2 T-bolt 26F M10 + P/F-rail 24/48 + Washer 9x35x2

Use and installation

Installation of Pendant/Fixing rail Check the position mark on the T-bolt M8 makes it possible to
on floor (or wall) with Angle bolt to ensure the right position of mount through the perforation of
bracket 5L and T-bolt. the T-bolt in the rail. Pendant/Fixing rail 24/48.

121
Expansion bolts
Electro-galvanized, hot dip galvanized or stainless steel AISI316. WEF-0001
For installation of all Wibe cantilever arms and vertical pieces.

Stainless steel
D L G Electro-galv Hot dip galv. (AISI316) Weight kg
mm mm mm Part. No. C* Part. No. C* Part. No. C* 100 pcs
Expansion bolt M6x40** 6 40 18 782222 5 782237 9 782252 2 1.04
Expansion bolt M6x65** 6 65 28 782223 2 782238 6 782253 9 1.54
Expansion bolt M8x50** 8 50 24 782224 9 782239 3 782254 6 2.22
Expansion bolt M8x95** 8 95 41 782225 6 782240 9 782255 3 3.61
Expansion bolt M8x120** 8 120 66 782226 3 782241 6 782256 0 4.35
Expansion bolt M10x60 10 60 29 782227 0 782242 3 782257 7 4.44
Expansion bolt M10x80 10 80 34 782228 7 782243 0 782258 4 5.32
Expansion bolt M10x100 10 100 54 782229 4 782244 7 782259 1 6.28
Expansion bolt M12x85 12 85 35 782230 0 782245 4 782260 7 8.17
Expansion bolt M12x100 12 100 50 782231 7 782246 1 782261 4 9.23
Expansion bolt M12x145 12 145 82 787052 3 787053 0 787054 7 12.5
Expansion bolt M16x110 16 110 53 782232 4 782247 8 782262 1 18.57
Expansion bolt M16x125 16 125 63 782233 1 782248 5 782263 8 20.4
Expansion bolt M16x150 16 150 76 782234 8 782249 2 782264 5 23.9
Expansion bolt M20x170 20 170 55 782235 5 782250 8 782265 2 44.83
Expansion bolt M20x220 20 220 55 782236 2 782251 5 782266 9 57.02
* EAN-code=732167+Part.no+C (control figure)
** M6 and M8 are delivered with an extra washer with a larger diameter. This washer must be mounted close to the
cantilever arm or vertical piece. The smaller standard washer must be put on top of the bigger washer close to the nut.
Use and installation

D1= Drill diameter


M = Installation depth
B = Min. drilling depth
T = Material thickness
Data for installation
Tightening
D1 B M T moment
Dim mm mm mm mm Nm
M6x40 6 35 30 5 7
M6x65 6 50 50 15 7
M8x50 8 45 35 5 20
M8x95 8 65 55 30 20
M8x120 8 65 55 55 20
M10x60 10 60 40 5 35
M10x80 10 70 60 10 35
M10x100 10 70 60 30 35
M12x85 12 80 50 5 55
M12x100 12 80 75 20 55
M12x145 12 80 75 60 55
M16x110 16 105 100 5 100
M16x125 16 105 100 20 100
M16x150 16 105 100 45 100
M20x170 20 150 120 20 240
M20x220 20 150 120 70 240
122
Expansion bolts
WEF-0001

Extraction force

Permitted extraction force in kN for various concrete qualities


Installation Concrete class
Dim depth mm C25 C30 C35 C40
M6 30 1.4 1.6 1.8 2.0
M6 40 2.3 2.8 2.9 3.0
M6 50 3.2 3.5 3.7 4.0
M8 35 1.6 1.8 2.0 2.3
M8 40 2.0 2.4 2.5 2.9
M8 55 3.3 3.8 4.0 4.7
M10 40 2.2 2.5 2.8 3.1
M10 60 4.0 4.5 5.0 5.6
M12 50 3.1 3.5 3.9 4.4
M12 75 6.5 7.4 7.8 9.3
M12 80 7.5 8.5 9.0 10.5
M16 100 9.4 10.7 12.0 13.4
M20 120 12.3 14.0 15.7 17.4

Transverse force

Permitted transverse force in kN for various concrete qualities


Installation Concrete class
Dim depth mm C25 C30 C35 C40
M6 30 1.1 1.3 1.5 1.6
M6 40 1.6 2.1 2.2 2.3
M6 50 2.2 2.4 2.6 2.8
M8 35 1.4 1.6 1.8 1.9
M8 40 2.0 2.2 2.4 2.5
M8 55 3.8 4.0 4.2 4.4
M10 40 1.6 1.8 2.0 2.2
M10 60 5.7 6.0 6.2 6.5
M12 50 2.2 2.5 2.7 3.0
M12 75 9.6 9.9 10.2 10.5
M12 80 10.6 11.0 11.4 12.2
M16 100 12.3 12.8 13.2 13.7
M20 120 15.9 17.0 17.5 19.3

123
Fixing system

124
Concrete screw MMS-S
For installation with cantilever arms and vertical pieces.
Concrete screw with hexagonal head and special thread constructed for safe fixing in concrete or brickwork.
Suitable for fixing of tubes, electrical installations, rails, handrails, machines, ventilating ducts, wood constructions.
❑ Easy to install
❑ High extraction values are obtained due to the special thread. The drill diameter is the same as the root diameter of the screw
which gives a solid fixing inside the hole.
❑ Can be dismounted and reinstalled without reduced extraction force.
❑ A weaker drill can be used compared to using anchor, expansion bolt, screw and plug.
❑ Suitable in environments which are fire classified.
Use and installation

Installation of cantilever arms. Installation of vertical pieces.

Concrete screw MMS-S


Electro-galvanized WEF-0001

A = Drill diameter
B = Min. installation depth
C = Min. drilling depth
F = Extraction force kN**
T = Transverse force kN
N = Width of jaws

**For concrete class C25

F T N ØxL A B C Number/ Weight kg


Part. No. C* kN kN mm mm mm mm mm package 100 pcs
MMS-S 6x401 787067 7 2.40 2.2 10 6x40 5 30 50 200 0.74
MMS-S 6x501 787047 9 2.80 2.2 10 6x50 5 30 50 100 0.92
MMS-S 6x601 787048 6 2.80 2.2 10 6x60 5 30 50 100 1.03
MMS-S 7.5x352 781550 0 2.50 4.8 13 7.5x35 6 30 50 100 1.2
MMS-S 7.5x402 781551 7 2.50 4.8 13 7.5x40 6 30 50 100 1.3
MMS-S 7.5x502 781552 4 3.00 4.8 13 7.5x50 6 30 50 100 1.4
MMS-S 10x60 781553 1 6.10 7.8 16 10x60 8 55 75 50 3.2
MMS-S 10x70 781554 8 6.10 7.8 16 10x70 8 55 75 50 3.4
MMS-S 10x80 781555 5 7.20 7.8 16 10x80 8 55 75 50 4.0
MMS-S 12x80 781556 2 8.00 7.8 18 12x80 10 60 80 25 6.0
1 Washer 7.0x16x1.5 Electro-galv. is included
2 Washer 8.4x19x1.5 Electro-galv. is included

*EAN-code=732167+Part.no+C (control figure)

125
Concrete screw MMS-S
Hot dip galvanized WEF-0001

A = Drill diameter
B = Min. installation depth
C = Min. drilling depth
F = Extraction force kN**
T = Transverse force kN
N = Width of jaws

**For concrete class C25


F T N ØxL A B C Number/ Weight kg
Part. No. C* kN kN mm mm mm mm mm package 100 pcs
MMS-S 6x401 790356 6 2.40 2.2 10 6x40 5 30 50 200 0.74
MMS-S 6x501 790357 3 2.80 2.2 10 6x50 5 30 50 100 0.92
MMS-S 6x601 790358 0 2.80 2.2 10 6x60 5 30 50 100 1.03
MMS-S 7.5x352 790359 7 2.50 4.8 13 7.5x35 6 30 50 100 1.2
MMS-S 7.5x402 790360 3 2.50 4.8 13 7.5x40 6 30 50 100 1.3
MMS-S 7.5x502 790361 0 3.00 4.8 13 7.5x50 6 30 50 100 1.4
MMS-S 10x60 790362 7 6.10 7.8 16 10x60 8 55 75 50 3.2
MMS-S 10x70 790363 4 6.10 7.8 16 10x70 8 55 75 50 3.4
MMS-S 10x80 790364 1 7.20 7.8 16 10x80 8 55 75 50 4.0
MMS-S 12x80 790365 8 8.00 7.8 18 12x80 10 60 80 25 6.0
1 Washer 7.0x16x1.5 Hot dip galv. is included
2 Washer 8.4x19x1.5 Hot dip galv. is inclcluded

*EAN-code=732167+Part.no+C (control figure)

Concrete screw MMS-S


Stainless steel AISI316 WEF-0001
Concrete screw with soldered phosphatized carbon steel tip.
L2
L1

A = Drill diameter
B = Min. installation depth
C = Min. drilling depth
F = Extraction force kN**
T = Transverse force kN
N = Width of jaws

**For concrete class C25

F T N ØxL1/L2 A B C Number/ Weight kg


Part. No. C* kN kN mm mm mm mm mm package 100 pcs

MMS-S 7.5x50/653 781557 9 3.00 4.8 13 7.5x50/65 6 30 85 50 1.9


MMS-S 10x70/85 781558 6 7.20 7.8 16 10x70/85 8 55 105 50 4.4
MMS-S 12x80/100 781559 3 8.10 7.8 18 12x80/100 10 60 120 25 7.6
3Washer 8.4x24x2.0 AISI316 is incl.

*EAN-code=732167+Part.no+C (control figure)

126
Concrete screw MMS-S FL
Electro-galvanized WEF-0001
Concrete screw with flange.

A = Drill diameter
B = Min. installation depth
C = Min. drilling depth
F = Extraction force kN**
T = Transverse force kN
D = Flange diameter
N = Width of jaws

**For concrete class C25

F T N ØxL D A B C Number/ Weight kg


Part. No. C* kN kN mm mm mm mm mm mm package 100 pcs
MMS-S FL 6x40 790394 8 2.40 2.2 10 6x40 15.0 5 30 50 100 0.8
MMS-S FL 6x50 790395 5 2.80 2.2 10 6x50 15.0 5 30 50 100 1.0
MMS-S FL 6x60 790396 2 2.80 2.2 10 6x60 15.0 5 30 50 100 1.1
MMS-S FL 7.5x50 790397 9 3.00 4.8 13 7.5x50 17.5 6 30 50 50 1.6
MMS-S FL 7.5x70 790398 6 3.00 4.8 13 7.5x70 17.5 6 30 50 50 2.0
MMS-S FL 10x70 790399 3 6.10 7.8 16 10x70 19.0 8 55 75 25 3.9
MMS-S FL 10x80 790400 6 7.20 7.8 16 10x80 19.0 8 55 75 25 4.5
MMS-S FL 12x90 790401 3 8.00 7.8 18 12x90 22.0 10 60 80 25 7.7
MMS-S FL 12x100 790402 0 8.00 7.8 18 12x100 22.0 10 60 80 25 8.5
*EAN-code=732167+Part.no+C (control figure)

Concrete screw MMS-S FL


Hot dip galvanized WEF-0001
Concrete screw with flange.

A = Drill diameter
B = Min. installation depth
C = Min. drilling depth
F = Extraction force kN**
T = Transverse force kN
D = Flange diameter
N = Width of jaws

**For concrete class C25

F T N ØxL D A B C Number/ Weight kg


Part. No. C* kN kN mm mm mm mm mm mm package 100 pcs
MMS-S FL 6x40 790376 4 2.40 2.2 10 6x40 15.0 5 30 50 100 0.8
MMS-S FL 6x50 790377 1 2.80 2.2 10 6x50 15.0 5 30 50 100 1.0
MMS-S FL 6x60 790378 8 2.80 2.2 10 6x60 15.0 5 30 50 100 1.1
MMS-S FL 7.5x50 790379 5 3.00 4.8 13 7.5x50 17.5 6 30 50 50 1.6
MMS-S FL 7.5x70 790380 1 3.00 4.8 13 7.5x70 17.5 6 30 50 50 2.0
MMS-S FL 10x70 790381 8 6.10 7.8 16 10x70 19.0 8 55 75 25 3.9
MMS-S FL 10x80 790382 5 7.20 7.8 16 10x80 19.0 8 55 75 25 4.5
MMS-S FL 12x90 790383 2 8.00 7.8 18 12x90 22.0 10 60 80 25 7.7
MMS-S FL 12x100 790384 9 8.00 7.8 18 12x100 22.0 10 60 80 25 8.5
*EAN-code=732167+Part.no+C (control figure)

127
Concrete screw MMS-PAN
Electro-galvanized WEF-0001
For installation of Pendant strip W33.
Panheaded concrete screw, electro-galvanized and yellow chromated. Torx-recess.

A = Drill diameter
B = Min. installation depth
C = Min. drilling depth
E = Screw head diameter
F = Extraction force kN**
T = Transverse force kN

**For concrete class C25

F T ØxL A B C E Number/ Weight kg


Part.No. C* kN kN Torx mm mm mm mm mm package 100 pcs
MMS-PAN 5x30 787049 3 0.8 1.4 T-20 5x30 4 25 45 7.9 200 0.32
MMS-PAN 5x50 787050 9 1.4 1.4 T-20 5x50 4 25 45 7.9 200 0.5
MMS-PAN 6x30 781560 9 2.40 2.2 T-30 6x30 5 25 45 11.5 200 0.65
MMS-PAN 7.5x45 781561 6 3.20 4.8 T-40 7.5x45 6 30 50 13 100 1.10
MMS-PAN 10x70 781562 3 7.20 7.8 T-40 10x70 8 55 75 17 50 3.40
*EAN-code=732167+Part.no+C (control figure)
Use and installation

Installation of Pendant strip W33. Mounting with JR-clamp.

Concrete screw MMS-PAN SH


Electro-galvanized WEF-0001
For installation of Ceiling attachment W31 or Tube pendant attachment W73.
Concrete screw with extra big panhead, electro-galvanized and yellow chromated. Torx-recess.

A = Drill diameter
B = Min. installation depth
C = Min. drilling depth
E = Screw head diameter
F = Extraction force kN**
T = Transverse force kN

**For concrete class C25

F T ØxL A B C E Number/ Weight kg


Part. No. C* kN kN Torx mm mm mm mm mm package 100 pcs
MMS-PAN SH 7.5x45 781696 5 3.00 4.8 T-30 7.5x45 6 30 50 17 100 1.4
*EAN-code=732167+Part.no+C (control figure)
Use and installation

Installation of Ceiling attachment


W31.
128
Concrete screw MMS-ST
Electro-galvanized WEF-0001
For installation of eye nuts. The screw is specially developed for safe fixing in concrete.
Suitable for tube installations, electrical installations, rails, handrails, machines, ventilating ducts, wood constructions.
A = Drill diameter
B = Min. installation depth
C = Min. drilling depth
E = Length of thread engagement
F = Extraction force kN**
T = Transverse force kN
N = Widths of jaws
M = English thread

**For concrete class C25


F T N DxL1 L2 A B C E Number/ Weight kg
Part. No. C* kN kN mm mm mm M mm mm mm mm package 100 pcs
MMS-ST 7.5x70 781563 0 3.20 4.8 10 7.5x70 53 M8 6 30 50 13 50 1.8
MMS-ST 10x80 781564 7 6.51 7.8 13 10x80 65 M10 8 55 75 10 50 3.5
*EAN-code=732167+Part.no+C (control figure)
Use and installation

Installation of eye nut.

Concrete screw MMS-I


Electro-galvanized WEF-0001
For installation of Pendant M8 or M10.
❑ High extraction values are obtained due to the special thread.
The drill diameter is the same as the root diameter of the screw which gives a solid fixing inside the hole.
❑ Can be dismounted and reinstalled without diminished extraction force.
❑ A weaker drill and less drilling depth can be used compared to using anchor, expansion bolt, screw and plug.
❑ Suitable in environments which are fire classified.

A = Drill diameter
B = Min. installation depth
C = Min. drilling depth
F = Extraction force kN**
T = Transverse force kN
N = Widths of jaws
M = Metrisk gänga

**For concrete class C25

F T N DxL1 L2 A B C Number/ Weight kg


Part. No. C* kN kN mm mm mm M mm mm mm package 100 pcs
MMS-I 7.5x55 781565 4 3.20 4.8 13 7.5x93 M8/M10 6 30 50 100 1.9
*EAN-code=732167+Part.no+C (control figure)
Use and installation

Installation of Threaded rod M8


or M10.
129
Eye screw MMS-R
Electro-galvanized WEF-0001
For installation of wires in ceiling.

A = Drill diameter
B = Min. installation depth
C = Min. drilling depth
F = Extraction force kN**
T = Transverse force kN

**For concrete class C25

F T ØxL A B C Number/ Weight kg


Part. No. C* kN kN mm mm mm mm package 100 pcs
MMS-R 6x40 781566 1 2.80 2.2 6x40 5 30 50 250 0.76
*EAN-code=732167+Part.no+C (control figure)

Light concrete screw


Electro-galvanized WEF-0001
For installation in porous concrete. Torx-recess.

B = Min. installation depth


E = Head diameter
F = Permitted extraction force kN

F ØxL B E Number/ Weight kg


Part. No. C* kN Torx mm mm mm package 100 pcs
Light concrete screw 8x100 790412 9 0.67 T-40 8x100 95 14.8 50 2.4
*EAN-code=732167+Part.no+C (control figure)

Expansion nail
Electro-galvanized/ Aluminium WEF-0001
For fixing of light details in concrete.
A = Drill diameter
B = Min. installation depth
C = Min. drilling depth

ØxL A B C Number/ Weight kg


Part. No. C* mm mm mm mm package 100 pcs
Expansion nail 5x22 790413 6 5x22 5 20 30 250 0.5
*EAN-code=732167+Part.no+C (control figure)

Mounting tool for Eye screw MMS-R


Electro-galvanized. WEF-0001

Number/ Weight kg
Part. No. C* package 100 pcs
Mounting tool for Eye screw MMS-R 781567 8 1 5.5
*EAN-code=732167+Part.no+C (control figure)

130
Bitro adapter
Electro-galvanized + plastic. WEF-0001
The Bitro adapter must be installed direct on Hammer drill SDS PLUS.
Drilling machine can be used. Suitable for drilling only in C25 concrete.

For drill D L Number/ Weight kg


Part. No. C* mm mm mm package 100 pcs
Bitro adapter 5, yellow 781568 5 5 10 73 1 2.5
Bitro adapter 6, green 781569 2 6 10 73 1 3.0
Bitro adapter 8, red 781570 8 8 12 80 1 4.0
Bitro adapter 10, blue 781571 5 10 14 80 1 5.0
*EAN-code=732167+Part.no+C (control figure)
Use and installation

Turn off the hammer function of the drilling machine. Install the Bitro When mounting use a drilling machine with torque regulator.
adapter on the drill. Check that the adapter locks the drill to avoid Otherwise be very careful. If you let the machine continue to run
turning. Put in Torxbits or Magnetic socket or Square peg + Socket when the screw is in bottom it is very easy to destroy the tip of the
16/18. When removing the adapter tilt it lightly and pull the bit, drill or that the drill gets stuck or broken. The risk increases with the
magnetic socket or the square peg. length of the drill.

Magnetic socket for Concrete screw MMS-S


Untreated steel. WEF-0001

Dim D Number/ Weight kg


Part. No. C* mm mm package 100 pcs
Magnetic socket 10x45 781572 2 10x45 10 1 2.5
Magnetic socket 13x45** 781573 9 13x45 13 1 3.0
**Can also be used for MMS-I.
*EAN-code=732167+Part.no+C (control figure)

Socket for Concrete screw MMS-S


Untreated steel. WEF-0001
To be used together with Square peg.

Dim D Number/ Weight kg


Part. No. C* mm mm package 100 pcs
Socket 16 781574 6 16x34 16 1 6.0
Socket 18 781575 3 18x34 18 1 10.0
*EAN-code=732167+Part.no+C (control figure)

131
Bits holder
Stainless steel AISI304. WEF-0001

Number/ Weight kg
Part. No. C* package 100 pcs
Bits holder 11x60 781576 0 1 2.5
*EAN-code=732167+Part.no+C (control figure)

Square peg
Untreated steel. WEF-0001
To be used with Socket 16 and 18.

Number/ Weight kg
Part. No. C* package 100 pcs
Square peg 3/8x50 781577 7 1 2.0
*EAN-code=732167+Part.no+C (control figure)

Torxbits
Untreated steel. WEF-0001
To be used with Concrete screw MMS-PAN SH.

Number/ Weight kg
Part. No. C* package 100 pcs
Torxbits TX 30x25 788552 7 2 0.5
Torxbits TX 40x25 788553 4 2 0.6
*EAN-code=732167+Part.no+C (control figure)

132
Hammer drill SDS PLUS
Untreated steel. WEF-0001

Cutting length
Dim of the drill Number/ Weight kg
Part. No. C* mm mm package 100 pcs
Hammer drill SDS PLUS 4x110 787021 9 4x110 50 1 3.0
Hammer drill SDS PLUS 5x110 781631 6 5x110 50 1 3.5
Hammer drill SDS PLUS 5x160 781632 3 5x160 100 1 4.0
Hammer drill SDS PLUS 5.5x110 787022 6 5.5x110 50 1 4.0
Hammer drill SDS PLUS 5.5x160 787023 3 5.5x160 100 1 4.0
Hammer drill SDS PLUS 6x110 781633 0 6x110 50 1 4.5
Hammer drill SDS PLUS 6x160 781634 7 6x160 100 1 5.0
Hammer drill SDS PLUS 6x210 781635 4 6x210 150 1 5.5
Hammer drill SDS PLUS 7x160 787025 7 7x160 100 1 5.5
Hammer drill SDS PLUS 7x210 787026 4 7x210 150 1 6.0
Hammer drill SDS PLUS 8x160 781636 1 8x160 100 1 6.0
Hammer drill SDS PLUS 8x210 781637 8 8x210 150 1 6.5
Hammer drill SDS PLUS 10x160 781638 5 10x160 100 1 7.5
Hammer drill SDS PLUS 10x210 781639 2 10x210 150 1 9.0
Hammer drill SDS PLUS 12x210 787027 1 12x210 150 1 9.5
Hammer drill SDS PLUS 16x300 787028 8 16x300 230 1 20.0
Hammer drill SDS PLUS 20x450 787029 5 20x450 370 1 56.0

Masonry drill WBL/WBE


Tungsten carbide tip.Tool steel shank with plated finish.
Masonry drill WBE 4x 75 787030 1 4x 75 40 1 2.0
Masonry drill WBE 5x 85 787031 8 5x 85 50 1 2.5
Masonry drill WBL 5x150 787032 5 5x150 60 1 2.0
Masonry drill WBE 5.5x 85 787033 2 5.5x 85 50 1 2.0
Masonry drill WBL 5.5x150 787034 9 5.5x150 90 1 2.0
Masonry drill WBE 6x100 787035 6 6x100 60 1 2.0
Masonry drill WBL 6x150 787036 3 6x150 90 1 4.0
Masonry drill WBE 7x100 787037 0 7x100 60 1 4.0
Masonry drill WBL 7x150 787038 7 7x150 90 1 4.0
Masonry drill WBL 7x300 787039 4 7x300 220 1 8.0
Masonry drill WBL 8x150 787040 0 8x150 90 1 4.0
Masonry drill WBL 8x200 787041 7 8x200 135 1 6.0
Masonry drill WBL 10x150 787042 4 10x150 90 1 6.0
Masonry drill WBL 10x200 787043 1 10x200 135 1 8.0
Masonry drill WBL 12x200 787044 8 12x200 135 1 10.0
Masonry drill WBL 16x300 787045 5 16x300 220 1 26.0
Masonry drill WBL 20x400 787046 2 20x400 230 1 62.0
*EAN-code=732167+Part.no+C (control figure)

133
Concrete screws - Loadings
Mounting of Wibe concrete screws
To use Wibe concrete screws is both safe and easy. No special tools or machines are required.
The screw performs an exact adapted thread in the bedding which means that no control of the tightening moment is required.

The extraction force of a Wibe concrete screw is better than that of an expansion bolt with the same diameter
You can choose a smaller diameter of a concrete screw than that of an expansion bolt and still receive the same extraction force.
The same concrete screw can be re-used.
Mounting instruction

Use a drill suitable to the screw. Switch off the hammer function. Mount with drilling machine.
Drill the hole. Mount the Bitro adapter on the Wibe concrete screws can also
drill. Pull in a bit or socket suit- be mounted with regular hand
able for the screw to be used. tools as box sockets.

1. Drill a hole with the same diameter as the root of the screw
(for 6 mm drill 5 mm, for 7.5 mm drill 6 mm, for 10 mm drill 8 mm and for 12 mm drill 10 mm).
The drill depth must be at least 20 mm deeper than the installation depth.

2. Blow the hole free from dust.

3. Mount the concrete screw close to the application bedding, no defined tightening moment is required.
Note – don´t tighten the screw with a higher moment than stated on the package or technical data.

Extraction forces, in kN, depending on installation depth in uncracked concrete C25.


Calculated values with a safety factor of 3.0.
Installation depth
mm MMS-5 MMS-6 MMS-7.5 MMS-10 MMS-12
25 0.8 2.02 2.15
30 1.4 2.40 2.50
35 2.50 2.60 3.50
40 2.80 3.00 3.80
45 2.80 3.20 4.00 5.50
50 2.80 4.10 4.30 6.30
55 6.10 6.10 7.20
60 2.80 6.51 7.20 8.00
70 7.90 8.10
80 10.00

Transverse forces Concrete screw MMS


Dimensioned transverse force in kN.
Concrete screw MMS-5 MMS-6 MMS-7.5 MMS-10 MMS-12
1.4 2.2 4.8 7.8 7.8

Screw diameter mm 5 6 7.5 10 12


Breaking torsional moment (Nm) 12 24 28 80 120
Recommended max 10 10 20 50 80
tightening moment (Nm)

Spacing
The above values are valid when the distance from the nearest corner or free edge to the screw is at least
10 x screw diameter. The spacing between two screws must be minimum 20 x screw diameter.

134
Low density anchor TLF
Hot dip galvanized WEF-0006
For fixing in light concrete or clinker concrete. For medium or heavy installations.
Unique advantages:
❑ Long expansion area and heavy expansion – very high loading values
❑ The expansion can be directed - superior loading values even at small edge distances.
❑ Very quick installation – drives in and expands with a hammer and Hammer tool TLF-S

DxL D1 Drill diameter Number/ Weight kg


Part. No. C* mm mm mm package 100 pcs
Low density anchor TLF 8x65** 781782 5 8x 65 13 8 50 1.4
Low density anchor TLF 12x100 781783 2 12x100 20 12 25 4.7
Low density anchor TLF 12x145 781784 9 12x145 20 12 25 6.2
Low density anchor TLF 16x130 781785 6 16x130 25 16 10 10.0
**One Hammer tool is incl. in each package.
*EAN-code=732167+Part.no+C (control figure)
Loading - All loadings refer to mounting in light concrete Y 500

Max Tightening moment Extraction force F1 Transverse force


M=Nm kN kN
TLF 8x65 mounted with wood screw TKX Fzb SPAX-5x35 1 0.3 0.3
TLF 12x100 mounted with hexagon head wood screw T6S 4.6 Fzv 8x40 6 0.6 0.6
TLF 12x145 mounted with hexagon head wood screw T6S 4.6 Fzv 8x40 6 0.6 0.6
TLF 16x130 mounted with hexagon head wood screw T6S 4.6 Fzv 10x40 10 0.6 0.6
Max permitted load F on Cantilever arm 50

50-200 50-300 50-400 50-500 50-600


Kg kN Kg kN Kg kN Kg kN Kg kN
TLF 8x 65
TLF 12x100 26 0.26 25 0.25 22 0.22 23 0.23 21 0.21
TLF 12x145 26 0.26 25 0.25 22 0.22 23 0.23 21 0.21
TLF 16x130 26 0.26 25 0.25 22 0.22 23 0.23 21 0.21
Use and installation

Drill with recommended drill Low density anchor TLF installed Lower the distance. Expand the anchor by means of
diameter, see above. (Without with Hammer tool TLF-S. Put the the Hammer tool.
pre-drilling in quality Y400 and hammer tool into the installation
Y450). hole of the low density anchor
and bolt the anchor.

135
Hammer tool TLF-S
Untreated steel. WEF-0001
For driving in and expansion of the Low density anchor TLF.

L Number/ Weight kg
Part. No. C* mm package 100 pcs
Hammer tool TLF-S 12x100 781842 6 180 1 23
Hammer tool TLF-S 12x145 781843 3 225 1 24
Hammer tool TLF-S 12x130 781844 0 220 1 42
*EAN-code=732167+Part.no+C (control figure)
Use and installation

Put the Hammer tool into the Lower the distance. Expand the anchor by means of
installation hole of the Low the Hammer tool.
density anchor and bolt the
fixing (without pre-drilling in qual-
ity Y400 and Y450).

Sleeve TLF-H12
Hot dip galvanized. WEF-0001
To be used together with Low density anchor TLF 12x100 or 12 x145
in order to raise the transverse force performance.

Number/ Weight kg
Part. No. C* package 100 pcs
Sleeve TLF-H12 781867 9 25 1.3
*EAN-code=732167+Part.no+C (control figure)
Use and installation

Put the sleeve on the Low Bolt the Low density anchor with
density anchor. the sleeve in level with the wall.
(See instructions for Low density
anchor TLF).

136
Adapter TLF-A12
Electro-galvanized. WEF-0007
To be used together with Low density anchor TLF 12x100 or 12x145
in order to receive an interior M10 thread.
Suits Pendant M10.

Number/ Weight kg
Part. No. C* package 100 pcs
Adapter TLF-A12 781868 6 10 2.1
*EAN-code=732167+Part.no+C (control figure)
Use and installation

Screw the Adapter into the Pendant M10 fits in the Adapter.
expanding Low density anchor.

Angled bracket TLF-F12


Pre-galvanized. WEF-0001
To be mounted with Low density anchor TLF 12x100 or 12x145
and can be used as fixing for band or wire installations.

Number/ Weight kg
Part. No. C* package 100 pcs
Angled bracket TLF-F12 781869 3 25 2.6
*EAN-code=732167+Part.no+C (control figure)
Use and installation

Mount the Angled bracket on the Bolt the Low density anchor with
Low density anchor. the Angled bracket into the bed-
(See instructions for Low density ding and check that it is secured.
anchor TLF).

137
Express hanger SVH
Stainless steel AISI316. WEF-0001
For fixing in concrete, natural stone, solid brick or plate.
Used for installation of armatures close to the ceiling (with locking block) as well as
for hanging of integrated ceilings, armatures, electrical-, tube- or ventilating equipment.
Mounting tool SVH-T, for mounting to the right installation depth, is included in the package.
Cover plate is included only for SVH-E1.

Drill Min. drilling depth Number/ Weight kg


Part. No. C* mm mm package 100 pcs
Express hanger SVH-E1 781870 9 8 30 100 0.3
Express hanger SVH-E2** 781871 6 8 30 500 0.3
**Cover plate not included.
*EAN-code=732167+Part.no+C (control figure)

Loading
Permitted load capacity at safety factor 3 at extraction
Concrete C25 kN Solid brick kN
Express hanger SVH-E1 1.0 0.5
Express hanger SVH-E2 1.0 0.5

Use and installation

Hole must be drilled with a 8 mm The short and stiff wire ends grip Mounting of wires. Cover plate Mounting close to the ceiling with
drill, drilling depth minimum 30 effectively into the sides of the hides the hole. Securing spring SVH-L.
mm. Drive in the Express hanger hole resulting in a safe and
with the Mounting tool SVH-T. strong fixing.
The installation depth always
turns out to be the right.

Express hanger SVH can also be When the fixing strip is turned At a visible installation, hide the
used for installation of Fixing into position it self-locks. Can hole with a cover plate. Delivered
strip TRB and TGB. also be locked with screw, rivet together with SVH-E1.
or lashing wire for extra security.

138
Securing spring SVH-L
Stainless steel AISI304. WEF-0001
For installation of armatures close to ceiling.

Number/ Weight kg
Part. No. C* package 100 pcs
Securing spring SVH-L 781872 3 25 0.20
*EAN-code=732167+Part.no+C (control figure)
Use and installation

For installation of armatures close


to the ceiling. Maximum loading
per securing spring is 4 kg.

Mounting tool SVH-T


Electro-galvanized. WEF-0001
For installation of Express hanger SVH.

Number/ Weight kg
Part. No. C* package 100 pcs
Mounting tool SVH-T 781873 0 10 1.8
*EAN-code=732167+Part.no+C (control figure)
Use and installation

For installation of Express


hanger SVH. The installation
depth will always turn out to be
the right.

139
Fixing strip TGB
Pre-galvanized. WEF-0001
For pendant installation and clamping
Cold-rolled and galvanized sheet metal, perforated for easy installations.
For fixing tools as Express hanger SVH or Low density anchor TLF with Angled bracket TLF-F12.

Number/ Weight kg
Part. No. C* Package 100 pcs
Fixing strip TGB 11x0.7 781874 7 1 (25m) 105
*EAN-code=732167+Part.no+C (control figure)
Use and installation

Can be mounted with Express Can be mounted with Low Can easily be mounted with other suitable fixing tools.
hanger SVH. density anchor TLF and
Angled bracket TLF-F12.

Fixing strip TRB


Stainless steel AISI304. WEF-0001
For pendant installation and clamping.
Stainless steel band AISI304 for qualified installations in all type of environments.
Express hanger SVH or Low density anchor TLF with Angled bracket TLF-F12 can be used as fixing tools.

Number/ Weight kg
Part. No. C* package 100 pcs
Fixing strip TRB 11x0.7 781875 4 1 (10m) 42
*EAN-code=732167+Part.no+C (control figure)
Use and installation

Can be mounted with Express Can be mounted with Low Can easily be installed with other suitable fixing tools.
hanger SVH. density anchor TLF and
Angled bracket TLF-F12.

140
Fixings - Ogebe
The Ogebe fixing is a patented fixing intended for use when mounting plating with a thickness of 0.7-0.9 mm and 13 mm gypsum board.
Pendants, cantilevers and holed strips can be mounted with these fittings.

Technical data
Material Cold-rolled sheet steel SS 1142–32 Nut Locking Nut M8, SMS 2165 FZB
Material treatment Case-hardened Bolt M8 x 16 mm FZB
Surface treatment Electro-galvanized Washer SRB 13.5 x 26 x 2 mm FZB
Maximum load See load tables

ø12 mm

0,7–0,9 mm

Drill a 12 mm dia. hole. A 10 mm Place the accompanying washer Mount the pendant, bracket or
drill can be used if one increases over the thin legs. Insert the legs holed strip with the enclosed
the hole dia. by slanting the through the drilled hole and fold bolts and nuts. (The nut should
electric drill. the broader legs towards each always be a locking nut).
other. If sealing is required, a
standard sealing mass from
building retailers can be used.
Breaking load
The load applied at an equi-distance between 2 beams 600 mm apart.
The values are taken from Swedish National Testing Institute Report 8410.0032 1984-09-28.

Fixing type E Fixing types D, ED Fixing type Eg

F3 F3 F3

F1 F1 F1

F3 F3 F3

F2 F2 F2

141
Ogebe fixing type E
WEF-0001
The Ogebe fixing type E is used for mounting in 0.7-0.9 mm sheeting or board material.
The following can be mounted: hole straps, pendants, ducts and pipings etc.

Electro-galv. Weight kg
Part. No. C* 100 pcs
Ogebe fixing type E 716474 5 4.8
*EAN-code=732167+Part.no+C (control figure)

Use and installation

Mounting of Pendant rail W32. Mounting of Pendant rail W32 Mounting of Ceiling attachment Mounting of hole strap.
with Ogebe fixing type E direct W31 on Ogebe fixing type E.
in lighting trunking.

Stand installation on wall. Suspension of duct or pipe. Mounting of holed beam. A wire can be mounted directly
in the Ogebe fixing type E.

The Ogebe fixing type E can be


mounted direct into Support
bracket/joint W7.

142
Ogebe fixing type D
WEF-0001
The Ogebe fixing type D is used for mounting in 0.7-0.9 mm sheeting or board material.
The following can be mounted: pendant fittings etc.

Electro-galv. Weight kg
Part. No. C* 100 pcs
Ogebe fixing type D 716475 2 6.8
*EAN-code=732167+Part.no+C (control figure)
Use and installation

Mounting of ceiling attachment Ogebe fixing type D or ED can


W31 on fixture, type D. be mounted in lighting trunking
Use Screw set W36 or W36C. as light fitting.

143
Ogebe fixing type ED
WEF-0001
The Ogebe fixing type ED is used for mounting in 0.7-0.9 mm sheeting or board material.
The following can be mounted: suspension devices, light fittings etc.

Electro-galv. Weight kg
Part. No. C* 100 pcs
Ogebe fixing type ED 716477 6 5.8
*EAN-code=732167+Part.no+C (control figure)

Use and installation

Mounting of Pendant attachment When mounting Ceiling attachment W31 on cable trays/lighting Installation of holed beam. Use
W21 or Tube pendant attach- trunking, the load can be distributed onto two or more fixings. Screw set W36/W36C.
ment W73 with Ogebe fixing type This allow for lateral adjustment.
ED. Use screw set W36/W36C.

Mounting of light fittings in plate metal ceiling. Stand installation on wall. Ogebe fixing type D or ED can
Use Screw set W36/W36C. be mounted in lighting trunking
as light fitting.

144
Ogebe fixing type Eg
WEF-0001
The Ogebe fixing type Eg is intended for mounting in single gypsum boards.

Eg

Electro-galv. Weight kg
Part. No. C* 100 pcs
Ogebe fixing type Eg 716478 3 5.6
*EAN-code=732167+Part.no+C (control figure)
Use and installation

Eg mounted in single gypsum Stand installation on wall.


board.

145
Integrated ceilings
Ceilings from Wibe provide undreamt of possibilities to build different types of system ceilings with very high demands on functionality.
You build using reliable, reputable components which are easy to install and combine in an almost neverending number of variations.

146
,

Acoustic lamina
We can supply acoustic lamina for baffle frames, wire baskets and The lamina comply with current standardes for fire-protection and
ceilings with T-profiles. are available with various sound absorption factors.
There are several manufacturers on the market offering lamina of
varying thicknesses, colours, suface coverings and structures.

It is possible to select the colour of your choice


Cable trays, lighting trunking, mounting fittings and accessories of choosing a coulor scheme for your ceiling thereby creating a
come in standard version in pre-galvaniced or pre-galvanized with pleasing atmosphere.
white paint finish (RAL 9010) design in accordance with the Zink- We can supply the whole of our programme in RAL colour of your
pox method. choice and with lustre you desire.
A celling often gives a room its character.Exploit the possibilities

147
Open ceilings

4
7
8

2
7 1

3 6

3 5 3
2

5 9

3
1

Components
1. Cable tray W1
2. Support bracket/joint W7
3. Tube pendant attachment W73
4. Pendant strip W33
5. T-joint W9 (alt. W29)
6. Junction box plate W24
7. Screw set W36
8. Screw set W38P
9. Threaded rod M10 W76

148
Ceilings with sound baffles

4
8

8
7 3
2 10
10
4
8

5
10
10
8
3 9
2 9
9

6 1
1 2
38
10 1
1

Components
1. Cable tray W1
2. Support bracket/joint W7
3. Pendant attachment W21
4. Ceiling attachment W31
5. Pendant rail W32
6. T-joint W9 (alt. W29)
7. Screw set W37
8. Screw set W38P
9. Sound baffles
10. Position retainer W43

149
Ceilings with wire baskets

8
5

3
1
7
4

8
5

3
2

6
10

2 6
10
1

Components
1. Cable tray W1
2. Support bracket/joint W7
3. Pendant attachment W21
4. Ceiling attachment W31
5. Pendant rail W32
6. T-joint W9 (alt. W29)
7. Junction box plate W24
8. Screw set W37
9. Screw set W38P
10. Wire baskets

150
Ceilings in corridor

1
5

30 B

1 3
4

2
8

1
5

Components
1. Cable trays and Lighting trunking
2. Suspension
3. Junction box plate
4. Support bracket/joint
5. Baffles, baskets etc.
6. W-swing profiles
7. W-swing wall bracket
8. Shade ledges, angle strips, integrated ceiling support channels
and wall trays

B= please state when ordering

151
Sound baffles
Wibe baffle frames are constructed of side and gable sections which are cut to measure
and mounted in accordance with customer requirements.
Baffles with hooks Baffles with rings

Baffles with hooks Baffles with suspension rings


The bottoms of the baffles and trays are on the same level. The rings are adapted to the W-swing profiles used in corridor
Hinged hooks installations.
The hooks allow the baffles to be lowered. However, this necessi- In this type of installation the baffles end up lower than the tray
tates that the space between tray and baffle may not be less then bottom.
25 mm.
Clearence hooks Position retainer
The hooks provide clearence and define the space between tray and 2 Position retainers W43 per baffle must be mounted diagonally.
baffle.
Mounting
Absorbents When installing the baffles directly in the trays normally 2 Hinged
The baffles are provided with optional acoustic lamina. There are hooks are fitted to the one end of the baffles and 2 Clearence hooks
several producers in the market who can offer acoustic lamina in in the other.
various thickness, colours and design. At installation without distance between baffle and tray 4 Hinged
Ordering hooks must be used.
When ordering please specify the following measurements:
L = Length of baffle Material
B = Width of baffle Made of pre-galvanized sheet steel + powder coated white. Other
C = Clearence measurement colours can be quoted.

Installation with Profile W-sving 2 Installation of suspended baffle Installation of suspended baffle
on Wall bracket W-sving 2. in Profile W-swing 3. in Profile W-swing 2 mounted on
Suspended baffle. Profile W-swing 4A.

Installation with tray and Profile Installation with tray and Profile
W-swing 5. Suspended baffle. W-swing 1. Suspended baffle.

152
Wire baskets

Wire baskets are an alternative to baffles. Material


They provide an open and airy atmosphere. Automatic welding of steel.
In shops and stores they provide good possibilities for
hanging advertisements, bargain offers and decorations. Surface treatment
The grating can be manufactured of wire with different diameters. Powder coated
Note that the shape of the mesh can either be square or rectangular.

Design Ordering
The welded grating is aesthetically attractive by simplicity, stability and plasticity. Please state the following
Abundance of variation due to the mesh pattern 50x50. L = Length of basket (mm)
Bigger mesh sizes can be offered. Standard pattern 50x50x4 mm. B = Width of basket (mm)

153
154
Accessories Sound baffles
The following accessories are included in an unassembled sound baffle:
4 Corners, 2 Hinged hooks, 2 Clearence hooks, 2 Side profiles and 2 Gable profiles.
Hinged hooks and clearence hooks can be replaced with suspension rings when necessary.
The baffles are easy to assemble without any tool.

Gable profile
WEF-0001

Pre-galv.
Length White30 Weight kg
mm Part. No. C* 100 pcs
Gable profile 570 570 728802 1 13.6
Gable profile 1170 1170 728803 8 27.9
*EAN-code=732167+Part.no+C (control figure)

Side profile
WEF-0001

Side profile for hook Side profile for suspension ring

Pre-galv.
Length White30 Weight kg
mm Part. No. C* 100 pcs
Side profile for hook 571-625 739535 4
Side profile for hook 626-749 739536 1
Side profile for hook 750-999 739537 8
Side profile for hook 1000-1170 739538 5
Side profile for hook 1171-1249 739539 2
Side profile for hook 1250-1400 739540 8
Side profile for hook 1401-1750 739541 5
Side profile for hook 1751-1990 739542 2
Side profile for hook 1991-2400 739543 9
*EAN-code=732167+Part.no+C (control figure)
Please state length of profile when ordering

Clearance hook
WEF-0001

Distance between baffle and tray Electro-galv. Weight kg


mm Part. No. C* 100 pcs
Clearance hook 25 25 720252 2 2.0
Clearance hook 30 30 720253 9 2.0
Clearance hook 40 40 720254 6 2.0
Clearance hook 50 50 720255 3 2.0
*EAN-code=732167+Part.no+C (control figure)
155
Hinged hook
WEF-0001

Distance between baffle and tray Electro-galv. Weight kg


mm Part. No. C* 100 pcs
Hinged hook 25-30 25-30 720260 7 2.0
Hinged hook 40 40 720261 4 2.0
Hinged hook 50 50 720262 1 2.0
*EAN-code=732167+Part.no+C (control figure)

Suspension ring
WEF-0001

Length Electro-galv. Weight kg


mm Part. No. C* 100 pcs
Suspension ring 575 575 728804 5 7
Suspension ring 1175 1175 728805 2 14
*EAN-code=732167+Part.no+C (control figure)

Reinforced profile
WEF-0001

Length White30 Weight kg


mm Part. No. C* 100 pcs
Reinforced profile 570 570 733995 2 13.6
Reinforced profile 1170 1170 733996 9 27.9
*EAN-code=732167+Part.no+C (control figure)

Corner
WEF-0001

Pre-galv Weight kg
Part. No. C* 100 pcs
Corner 720286 7 2.5
*EAN-code=732167+Part.no+C (control figure)

156
Gypsum clip
Used to mount gypsum wallboards in baffle frames. WEF-0001

Steel strip Weight kg


Part. No. C* 100 pcs
Gypsum clip 732241 1 0.4
*EAN-code=732167+Part.no+C (control figure)
Use and installation

Gypsum boards in Wibes baffle Lock the gypsum clip by pressing Normally it is enough with 4
frames must have dimensions down the tab. gypsum clips pro baffle. The clips
that are 20 mm smaller than the The gypsum clip suits a must be mounted diagonally.
size of the baffle. The clip will 9 mm thick board.
keep the board in place.
Position retainer W43
Support W42
WEF-0017

Position retainer W43 Support W42


Two pcs are mounted per baffle. Mounted in T-joint W9 as a support for cables.

White plastic Weight kg


Part. No. C* 100 pcs
Position retainer W43 718245 9 0.4
Support W42 718214 5 0.4
*EAN-code=732167+Part.no+C (control figure)
Use and installation

Position retainer W43 holds the Support W42 is mounted at


sound baffles in the correct T-joint W9 to prevent the cables
position. W 43 is snapped tight from gliding out over the corner
into the edge of the cable tray or of the cable tray or lighting
lighting trunking. trunking. W42 is snapped tight
into the edge of the tray.

157
Frame clip W90
Enables clip mounting in baffle frame. WEF-0001

Pre-galv. Weight kg
Part. No. C* 100 pcs
Frame clip W90 (screw RXS Combi B6x19, fzb) 723021 1 1.0
*EAN-code=732167+Part.no+C (control figure)
Use and installation

The Frame clip W90 is clamped Mounting of light fittings on Installation of air component. Mounting of decoration strip etc.
tight under the edge of the Reinforced profile.
section.

T-section is easily mounted with In large frames an extra support Light fitting mounted in baffle frame.
Frame clips W90 in the baffle for the absorbent lamina can be 2 T-profiles mounted with 4 Frame clips W90.
frames. required. Install a T-section with
2 Frame clips W90.

158
Ceilings in corridor

159
Profile W-swing 1/40
A profile that will simplify service and maintenance, used for mounting on trays with edge height 40 mm. WEF-0001
600 mm c/c is standard. Other c/c measurements can be manufactured on request.

White30 Weight kg
Part. No. C* 100 pcs
Profile W-swing 1 729196 0 210
*EAN-code=732167+Part.no+C (control figure)
Use and installation

Installation with tray on both sides and Profile W-swing 1 hanging on tray Installation with tray and Profile W-swing 1. Suspended baffles,
edge. Suspended baffle, folding in both directions. folding in both directions. The trays have pendular suspension from ceiling.

Profile W-swing 1/60


A profile that will simplify service and maintenance, used for mounting on trays with edge height 60 mm. WEF-0001
600 mm c/c is standard. Other c/c measurements can be manufactured on request.

White30 Weight kg
Part. No. C* 100 pcs
Profile W-swing 1/60 786871 1 200
*EAN-code=732167+Part.no+C (control figure)
Use and installation

Installation with tray on both sides and Profile W-swing 1 hanging on tray Installation with tray and Profile W-swing 1. Suspended baffles, folding in
edge. Suspended baffle, folding in both directions. both directions. The trays have pendular suspension from ceiling.

160
Profile W-swing 2
A profile that will simplify service and maintenance. WEF-0001
600 mm c/c is standard. Other c/c measurements can be manufactured on request.

Pre-galv.
Pre-galv. White30 Weight kg
Part. No. C* Part. No. C* 100 pcs
Profile W-swing 2 728866 3 730162 1 110
*EAN-code=732167+Part.no+C (control figure)
Use and installation

Installation with Profile W-swing 2 on Wall bracket W-swing 2. Ceiling installation with Profile W-swing 2. Suspended baffle, folding
Suspended baffle, folding in both directions. in both directions.

When joining, Ceiling bracket Profile W-swing 2 can be Profile W-swing 2 can be
W31 can be both joint and ceiling suspended in Pendant attach- suspended in Pendant strip W33.
bracket. Mounted with Screw set ment W21. Mounted with Screw Mounted with Screw set W34.
W34. set W34.

161
Wall bracket W-swing 2
WEF-0001
Used for installation with Profile W-swing 2.

Pre-galv.
Pre-galv. White30 Weight kg
Part. No. C* Part. No. C* 100 pcs
Wall bracket W-swing 2 721175 3 729067 3 16
*EAN-code=732167+Part.no+C (control figure)

Use and installation

Wall bracket W-swing 2 mounted on pendant or direct on wall. Profile W-swing 2 mounted on
Wall bracket W-swing 2 with
Screw set W34. The profile can
easily be adjusted in the oval
holes of the wall bracket and the
profile. Infinitely variable length-
wise and ± 20 mm towards wall.

162
Profile W-swing 3
WEF-0001
A profile that will simplify service and maintenance.
600 mm c/c is standard. Other c/c measurements can be manufactured on request.

White30 Weight kg
Part. No. C* 100 pcs
Profile W-swing 3 729198 4 277
*EAN-code=732167+Part.no+C (control figure)
Use and installation

Installation with tray and Profile W-swing 1, Wall bracket W-swing 2


with Profile W-swing 2 and pendant with Profile W-swing 3.
Hanging baffles, folding in both directions

When joining, Ceiling bracket Profile W-swing 3 can be Profile W-swing 3 can be
W31 can be both joint and ceiling suspended in Pendant attach- suspended in Pendant strip W33.
bracket. Mounted with Screw set ment W21. Mounted with Screw Mounted with Screw set W34.
W34. set W34.

163
Profile W-swing 4A
WEF-0001
A profile that will simplify service and maintenance.
600 mm c/c is standard. Other c/c measurements can be manufactured on request.

White30 Weight kg
Part. No. C* 100 pcs
Profile W-swing 4A 731618 2 150
*EAN-code=732167+Part.no+C (control figure)
Use and installation

For suspension of baffles, Profiles W-swing 2 och W-swing W-swing 4A can be suspended
Profile W-swing 4A is used 4A mounted with Screw set W34. in Pendant attachment W21.
in combination with Profile
W-swing 2. Mounted with Screw
set W34.

W-swing 4A can be suspended When joining, Ceiling bracket


in Pendant strip W33. W31 can be both joint and ceiling
bracket. Mounted with Screw set
W34.

164
Profile W-swing 5
A profile that will simplify service and maintenance. WEF-0001
600 mm c/c is standard. Other c/c measurements can be manufactured on request.

White30 Weight kg
Part. No. C* 100 pcs
Profile W-swing 5 729200 4 200
*EAN-code=732167+Part.no+C (control figure)
Use and installation

Installation with tray and Profile


W-swing 5. Baffle in level with tray
and folding in both directions.

Shade ledge W26/40


Used as a support for ceilings mounted between cable trays with edge height 40 mm. WEF-0001

Plate Pre-galv.
thickness Pre-galv. White30 Weight kg
mm Part. No. C* Part. No. C* 100 pcs
Shade ledge W26/40 1.0 717990 9 729192 2 154
*EAN-code=732167+Part.no+C (control figure)
Use and installation

Shade ledge W26/40 is hung Shade edge W26/40 is used as a Shade list W26/40 is locked tight
over the side edge of the cable support for ceilings mounted in the tray by pinching the ends
tray. between cable trays. Also suit- in under the tray edge with pliers.
able for Lighting trunking W70/
W71. Mounted along the side
edges of the cable tray or the
lighting trunking.

165
Shade ledge W26/60
Used as a support for ceilings mounted between cable trays with edge height 60 mm. WEF-0001

Plate Pre-galv.
thickness Pre-galv. White30 Weight kg
mm Part. No. C* Part. No. C* 100 pcs
Shade edge W26/60 1.0 718559 7 782661 2 185
*EAN-code=732167+Part.no+C (control figure)
Use and installation

Shade ledge W26/60 is hung Shade edge W26/60 is used as a Shade list W26/60 is locked tight
over the side edge of the cable support for ceilings mounted in the tray by pinching the ends
tray. between cable trays. in under the tray edge with pliers.
Mounted along the side edges of
the cable tray.

Integrated ceiling support channel


W27/40
Used as a support for ceilings mounted between cable trays with edge height 40 mm. WEF-0001

Plate Pre-galv.
thickness Pre-galv. White30 Weight kg
mm Part. No. C* Part. No. C* 100 pcs
Integrated ceiling support channel W27/40 1.0 714008 4 729193 9 130
*EAN-code=732167+Part.no+C (control figure)
Use and installation

Integrated ceiling support


channel W27/40 is hung over
and mounted along the side
edge of the cable tray and
is used as a support for ceil- Integrated ceiling support channel
ings mounted between cable W27/40 is locked tight in the tray
trays. Also suitable for Lighting by pinching the ends in under the
trunking W70/W71. tray edge with pliers.

166
Integrated ceiling support channel
W27/60
Used as a support for ceilings mounted between cable trays with edge height 60 mm. WEF-0001

Plate Pre-galv.
thickness Pre-galv. White30 Weight kg
mm Part. No. C* Part. No. C* 100 pcs
Integrated ceiling support channel W27/60 1.0 718556 6 782662 9 160
*EAN-code=732167+Part.no+C (control figure)
Use and installation

Integrated ceiling support channel Integrated ceiling support channel


W27/60 is used as a support for W27/60 is locked tight in the tray
ceilings mounted between cable by pinching the ends in under the
trays. Mounted along the side tray edge with pliers.
edge of the cable tray.

Angle strip W46


Used as a support for ceiling installations. WEF-0001

Plate Pre-galv.
thickness Pre-galv. White30 Weight kg
mm Part. No. C* Part. No. C* 100 pcs
Angle strip W46 0.6 718608 2 729194 6 52
*EAN-code=732167+Part.no+C (control figure)
Use and installation

Angle strip W46 is mounted


directly onto wall, column or
similar as a support for baffles or
ceiling lamina.

167
Wall tray W60/40
Wall tray with edge height 60 mm used for mounting of ceiling in corridor. WEF-0001
The tray is mounted directly onto the wall.

L Pre-galv. Pre-galv. White30 Weight kg


mm Part. No. C* Part. No. C* 100 pcs
Wall tray W60/40 2000 718383 8 729195 3 135
*EAN-code=732167+Part.no+C (control figure)
Use and installation

Wall tray W60 is mounted directly Mounting of ceiling in corridor when canalisation on one side is
onto the wall. required but with the same functionality as for cable trays on both
sides.

Wall tray W60/60


Wall tray with edge height 60 mm used for mounting of ceiling in corridor. WEF-0001
The tray is mounted directly onto the wall.

Plate Pre-galv.
thickness Pre-galv. White30 Weight kg
mm Part. No. C* Part. No. C* 100 pcs
Wall tray W60/60 1.0 787182 7 782783 1 333
*EAN-code=732167+Part.no+C (control figure)
Use and installation

Wall tray W60/60 is mounted Mounting of ceiling in corridor when canalisation on one side is
directly onto the wall. required but with the same functionality as for cable trays on both
sides.

168
Installation examples

Use Vertical piece 2F at installa- Example of corridor installation. This way of mounting reduce the
tions in corridors with gypsum obliquity of the cable tray.
walls. The installation can easily
be adjusted both vertically and
horizontally and will not be
effected of vibrations in the walls.

Example of installation with uneven loadings. The installation has Internal cantilever arm can be
been reinforced with lashing wires. The wire can be fixed to the ceil- mounted right over support
ing or the ceiling bracket. bracket/joint.

Mounting of Pendant rail W32 The Ogebe fixing type E can be Ogebe fixing type D or ED can
with Ogebe fixing type E direct in mounted direct into Support be mounted in lighting trunking
lighting trunking. bracket/joint W7. as light fitting.

169
170
171
172
Management system - Quality and Environment
Wibe has a third-party certified management system for
quality and environment in accordance with ISO 9001:2000
and ISO 14001:2004

AB WIBE
Box 401, SE-792 27 MORA, Sweden
Telephone +46 250 280 00, Telefax +46 250 188 55
e-mail: info@wibe.se, www.wibe.se

You might also like