----Messages---Message1 Fault 1! Wire break suction pressure sensor! Message2 Fault 2! Wire break oil pressure sensor!

Message3 Fault 3! Wire break discharge pressure sensor! Message4 Fault 4! Wire break discharge temperature sensor! Message5 Fault 5! Wire break oil temperature sensor! Message6 Fault 6! Wire break slide position indicator! Message7 Fault 7! Message8 Fault 8! Message9 Fault 9! Wire break secondary refrigerant tempera ture sensor! Message10 Fault 10! Wire break filter pressure sensor! Message11 Fault 11! Line break11

Message12 Fault 12! Line break12 Message13 Fault 13! Line break13 Message14 Fault 14! Line break14 Message15 Fault 15! Line break15 Message16 Fault 16! Line break16 Message17 Fault 17! Suction pressure too low! Message18 Fault 18! Message19 Fault 19! Discharge pressure too high! Message20 Fault 20! Discharge temperatur e too high! Message21 Fault 21! Oil temperature too high! Message22 Fault 22!

Unloading time too long! Message23 Fault 23! Message24 Fault 24! Message25 Fault 25! Secondary refrigerant temperature too low! Message26 Fault 26! Message27 Fault 27! Limit value11 Message28 Fault 28! Limit value12 Message29 Fault 29! Limit value13 Message30 Fault 30! Limit value14 Message31 Fault 31! Limit value15 Message32 Fault 32! Limit value16 Message33 Fault 33! Message34 Fault 34!

Motor temperature too high! Message35 Fault 35! Emergency switch or safety chain has responded! Message36 Fault 36! Star - delta time too long or no feedback signal! Message37 Fault 37! Safety chain of compressor motor has responded! Message38 Fault 38! Liquid level too high! Message39 Fault 39! Message40 Fault 40! Oil pressure or oil flow too low! Message41 Fault 41! Preliminary oil filter blocked! Message42 Fault 42! MPI- communication! Message43 Fault 43! Refrigerant leak detected! Message44 Fault 44! flow switch sec.refrig.circuit

Message45 Fault 45! Message46 Fault 46! Message47 Fault 47! Message48 Fault 48! Message49 Warning 1! Suction pressure too low! Message50 Warning 2! Message51 Warning 3! Discharge pressure too high! Message52 Warning 4! Discharge temperature too high! Message53 Warning 5! Oil temperature too high! Message54 Warning 6! Message55 Warning 7! Message56 Warning 8! Message57 Warning 9! Secondary refrigerant temperature too low! Message58 Warning 10! Message59 Warning 11!

Wire break Vi position indicator! Message60 Warning 12 (#1comp.) Wire break ECOpressure! Message61 Warning 13 (#1comp.) Wire break ECOtemp.! Message62 Warning 14 (#1comp.) Wire break glykol inlet temp.! Message63 Warning 15!(#1comp.) Message64 Warning 16! Oil separator level too high Message65 Warni 17! Oil pressure loss over filter near to the limit! Message66 Warning 18! No feedback from refrigerant pump motor! Message67 Warning 19! No feedback from condenser system (fans or pumps)! Message68 Warning 20!Central control prohibited in local control mode! Message69 Warning 21! Program buffer battery empty.

Message70 Warning 22! Oil separator level too low Message71 Warning 23! Wire break motor current transformer! Message72 Warning 24! Wire break suction temperature sensor! Message73 Warning 25! Message74 Warning 26! Message75 Warning 27! Message76 Warning 28! Message77 Warning 29! Message78 Warning 30! Message79 Warning 31! Message80 Warning 32! Message81 Warning 33! Message82 Warning 34! Message83 Warning 35! Message84 Warning 36! Message85 Warning 37! Message86 Warning 38! Message87

Warning 39! Message88 Warning 40! Message89 Warning 41! Message90 Warning 42! Message91 Warning 43! Message92 Warning 44! Message93 Warning 45! Message94 Warning 46! Message95 Warning 47! Message96 Warning 48! Message97 Message98 ----EVENT MESSAGES / STATUS MESSAGES------------------------------Message1 GEA Grasso GmbH Refrigeration Technology +49(0)172/3912050 Message2 BM 1 Message3 ECO in operation + Motor in delta operation Message4 BM 3 Message5 BM 4 Message6 BM 5 Message7

BM 6 Message8 BM 7 Message9 BM 8 Message10 BM 9 Message11 BM 10 Message12 BM 11 Message13 Start to start timer is still active for @s! Message14 oil cooler injection is still active! (option) Message15 Motor current limitation is still active! Message16 Discharge pressure limitation is still active! Message17 Suction pressure limitation is still active! Message18 BM 17 Message19 BM 18 Message20 BM 19 Message21 BM 20 Message22 BM 21 Message23

BM 22 Message24 BM 23 Message25 BM 24 Message26 BM 25 Message27 BM 26 Message28 BM 27 Message29 BM 28 Message30 BM 29 Message31 BM 30 Message32 BM 31 Message33 BM 32 Message34 BM 33 Message35 BM 34 Message36 BM 35 Message37 BM 36 Message38 BM 37 Message39 BM 38 Message40 BM 39 Message41 BM 40 Message42 Status message 0 Compressor off

Message43 Status message 1 Forced unloading on Message44 Status message 2 Motor in star operation Message45 Status message 3 Motor in delta operation Message46 Status message 4 Stop procedure is on Message47 Status message 5 Oil pump running by itself Message48 Status message 6 Oil drain timer is still active Message49 Status message 7 Stop to start timer is still active Message50 `t Message51