PROJECT: NAVA BHARAT VENTURES LIMITED, PALONCHA PACKAGE: 1 x 150 MW BTG PACKAGE 150 MW ESP TECHNNICAL DATA SHEET

** All details mentioned below are tentative and prior to Detailed engineering. They are subject to change without compromising the basic paramters of efficiency and emission

TECHNICAL DATA S.No Description A 1 2 3 4 5 6 7 8 Input Data Type of Boiler Boiler capacity Fuel Fired Gas volume (MCR/DESIGN) (app) Gas Temperature (MCR/Design) Gas Moisture (app) Inlet Dust Concentration (MCR/DESIGN) Emission Required a) All fields working (Guarantee/Design) b) With one field out of service (Guarantee/Design) Suction Pressure Design Pressure No.of fields No of Streams Technical Data Manufacturer Type Design Manufacturer's model no. Dimensions a) Width(across gas flow) each ESP b) Flange to flange length (in direction of gas flow) c) Height between support level to top of monorail beam d) Height between top insulator compartment to top of monorail beam e) Field width f) Field Height g) Field Length h) No. of gas passages i) Spacing of gas passages Collecting surface spacing Collecting surface height Collecting surface length per field Number of electrical fields in series Number of gas streams per ESP Maximum Bus Voltage Average Bus Voltage Installed & Consumption Power of ESP a) TR Sets b) Collecting Electrodes Rapper Motors c) Discharge Electrodes Rapper Motors d) HT isolator Switches e) Insulator heaters f) Hopper heaters
Page 1 of 5

UOM PALONCHA CFBC TPH, Kg/cm 0 (g), C


2

m3/s 0 C % by volume gm/Nm3 mg/Nm3 mg/Nm mm WG mmWC Nos. Nos.


3

520 Indian Coal 328 150 10 60 50 100 -400 25 2X7 Two Sunyard /Tianhe/ Alstom / VT Corp/Thermax/equiv. Horizontal STD STD

9 10 11 12 B 1 2 3 4 5

mtrs mtrs mtrs mtrs mtrs mtrs mtrs mm mm mtrs mtrs Nos. KV KV KW

12 38

6 7 8 9 10 11 12 13

11.2 15 3.75 28 400 400 15000 3750 x 7 7 2 95 58 later

PROJECT: NAVA BHARAT VENTURES LIMITED, PALONCHA PACKAGE: 1 x 150 MW BTG PACKAGE 150 MW ESP TECHNNICAL DATA SHEET
** All details mentioned below are tentative and prior to Detailed engineering. They are subject to change without compromising the basic paramters of efficiency and emission

TECHNICAL DATA S.No Description g) others, if any Guaranteed Power Consumption for ESP Guaranteed Collection efficiency Guaranteed Pressure drop across ESP Guaranteed air in leakage rate Specific collection area and the corresponding gas flow Total active collection area Projected collection area Treatment time and the corresponding gas flow, Treatment length Gas velocity through ESP Aspect Ratio Effective migration velocity Outlet dust concentration with one field outof service Outlet dust concentration with two fields outof service Collection efficiency with one field out of serc. Collection efficiency with two fields out of serc. Gas temperature drop across ESP at the guarantee point flow Design Pressure Design temperature Predicted performance of design Inlet Dust Concentration (MCR/DESIGN) Outlet dust concentration a) With all fields working (MCR/DESIGN) b) With one field out of service Collection efficiency with one field out of service Collection efficiency with two fields out of service collection efficiency of (with all fields work) a) First filed b) Second field c) Third field d) Fourth field e) Fifth field Gas temperature drop across esp at the guarantee point flow Max.available corona power per 100SQ.M surface Casing Material Plate thickness Design pressure Design temperature Max.temperature withstand capacity and duration Number of inspection doors.each ESP Dimensions of access openings of insp.doors UOM PALONCHA 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 C 1 2 KW % mmWC cu.m/s m2/m3/s & m3/s m2 m2 sec & m3/s mtrs m/s cm/s

Only emission is guaranteed 25 later 134.45/ 328 2 x 22050 as above 26.89 / 328 7 x 3.75 0.97 1.75 later 100 N/A Emission is guaranteed only N/A

C mmWC 0 C gm/Nm3 mg/Nm3

5 to 7 -450
250

60 50 100 Emission is guaranteed only N/A Emission is guaranteed only

3 4 5

6 7 D 1 2 3 4 5 6 7

C WATTS

5 to 7 17.4 M.S 5 -450 200 250 at 30 mnts 22 500 x 700

mm mmWC 0 C 0 C

Page 2 of 5

PROJECT: NAVA BHARAT VENTURES LIMITED, PALONCHA PACKAGE: 1 x 150 MW BTG PACKAGE 150 MW ESP TECHNNICAL DATA SHEET
** All details mentioned below are tentative and prior to Detailed engineering. They are subject to change without compromising the basic paramters of efficiency and emission

TECHNICAL DATA S.No Description 8 9 10 E 1 2 3 4 5 6 7 8 F 1 2 3 4 5 6 7 8 9 10 11 Complete Staircase from ESP support baseupto the ESP roof on one side of ESP (size) Grating of platforms, stair treads for staircase (size) PTFE slide bearings Gas Distribution System Method of ensuring uniform gas distribution Number of distribution plates/screens Material Thickness of distribution screen in series Number of gas distribution screens in series Free area per gas screen Dimensions of opening in the screen Details of rapping gear for distribution plates Emitting Electrodes Type Material of the electrode Material of the frame Configuration Diameter/ Thickness Height in contact with gas Total effective electrode length No. of electrodes per ESP Method of suspension Spacing of electrodes in the direction of gas flow Size and weight of pipe frames(diameter & schedule) a) vertical frames b) cross frames Surface preparation and painting Weight of an assembled frame associated with single rapper Max. Available corona current per linear meter of electrode a) First field b) Second field c) Third field d) Fourth field e) Fifth field Collecting Electrodes Type Material Size of electrodes a) width b) height c) thickness Effective height and width of contact with gas ,each ESP Number of gas passages per gas stream
Page 3 of 5

UOM PALONCHA Provided As per Mfg standard

mm mtrs mtrs

Spiral S.S as per UHB 904L M.S Spiral 2.7 diameter 15 5

mtrs

mtrs mtrs

12 13 14

Kg

mA mA mA mA

G 1 2 3

modified G profile As per IS 513 mm mm mm mtrs 750 15000 1.25 15 x 0.75

4 5

PROJECT: NAVA BHARAT VENTURES LIMITED, PALONCHA PACKAGE: 1 x 150 MW BTG PACKAGE 150 MW ESP TECHNNICAL DATA SHEET
** All details mentioned below are tentative and prior to Detailed engineering. They are subject to change without compromising the basic paramters of efficiency and emission

TECHNICAL DATA S.No Description 6 7 8 9 10 Spacing of gas passages Total effective cross sectional area per gas stream Total effective collection surface area Weight of collection surface associated with a single rapper Max.available corona current per square metre of effective collecting surface a) First field b) Second point c) Third field d) Fourth field e) Fifth field Max.available corona power per SQ.M of effective collecting surface Number of collecting electrodes per ESP Effective collection surface area per electrode Method of suspension &Inspection Surface preparation and painting Surface finish of the collecting electrode Dust Hoppers Type Number of hoppers / ESP Material Plate thickness Side angle Valley angle Storage capacity of each hopper(hour of operation) Volumetric storage capacity of each hopper No. and height of gas screens per hopper Baffle plates in hopper No.of access doors per hopper Access door dimensions Height of the hopper bottom flanges above the ground level Size of hopper outlet flanges Hopper heating arrangement a) No. of heaters per hopper b) Rating and other data of heater c) Heater temp. control Hopper dust level detectors a) Number per hopper b) Type Ash collection rate a) First field b) Second field c) Third field
Page 4 of 5

UOM mm 2 m m2 KG PALONCHA 400

mA/m2 mA/m2 mA/m2 mA/m2

11 12 13 14 15 16 P 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

WATTS/m 2 m2

mm C 0 C
0

Pyramid 14 M.S 5 65 4

m3

mm x mm mtrs mm

One 500 x 700 3 400 x400 Tubular type Four 1 kw per heater Thermostatic R.F type One Tubular type

16

17

Kg/hr Kg/hr Kg/hr

PROJECT: NAVA BHARAT VENTURES LIMITED, PALONCHA PACKAGE: 1 x 150 MW BTG PACKAGE 150 MW ESP TECHNNICAL DATA SHEET
** All details mentioned below are tentative and prior to Detailed engineering. They are subject to change without compromising the basic paramters of efficiency and emission

TECHNICAL DATA S.No Description d) Fourth field e) Fifth field Power consumption (KW) for the gas stream Normal K.W M.C.R T.R set Collecting electrode rapper Discharge electrode rappers Insulator heaters Insulator fans Hopper heaters Any other load Total Insulation And Cladding Areas to be insulated for precipitator a) casing b) Hoppers c) Roof d) Nozzles e) Any other f) Total Material Insulating material standard Thickness Density Thermal conductivity at mean temperature of a)50deg.C b)100deg.C c)150deg.C d)200deg.C Resistive to micro-organism (yes/no) Incombustibility (yes/no) Material of skin casing Thickness of skin casing Cladding a) material b) Thickness Auxiliary control Panel Class of Protection Feeders list details Module type(drawout/Non-drawout) Make(Vendors list) Dimensions UOM PALONCHA Kg/hr Kg/hr later

1 2 3 4 5 6 7 8 R 1

m2 m2 m2 m2 m2 m2

2 3 4 5 6

mm Kg/m3 Not in scope (k.cal/m/hr/deg. (k.cal/m/hr/deg. (k.cal/m/hr/deg. (k.cal/m/hr/deg.

7 8 9 10 11

mm

S 1 2 3 4 5

IP 52 not in scope not in scope