NATIONAL ENVIRONMENTAL QUALITY STANDARDS FOR MUNICIPAL AND LIQUID INDUSTRIAL EFFLUENTS (mg/l, UNLESS OTHERWISE DEFINED) S. No .

1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Parameter Existing Standards Revised Standards Into Inland Waters 2 Temperature or Temperature Increase * pH value Biochemical Oxygen Demand (BOD)5 at 20oC (1) Chemical Oxygen Demand (COD)(1) Total suspended solids (TSS) Total dissolved solids (TDS) Grease and oil Phenolic compounds (as phenol) Chloride (as Cl) Fluoride (as F) Cyanide (as CN) total An-ionic detergents (as MBAs) () Sulphate (SO) Sulphide (S) Ammonia (NH) Pesticides (3) Cadmium (4) Chromium (trivalent and hexavalent)(1) Copper (4) Lead (4) Mercury (4) Selenium (4) Nickel (4) Silver (4) 3 40oC 6 - 10 80 150 150 3500 10 0.1 1000 20 2 20 600 1.0 40 0.15 0.1 1.0 1.0 0.5 0.01 0.5 1.0 1.0 4 =<3oC 6-9 80 150 200 3500 10 0.1 1000 10 1.0 20 600 1.0 40 0.15 0.1 1.0 1.0 0.5 0.01 0.5 1.0 1.0 Into Sewage Treatment 5 =<3oC 6-9 250 400 400 3500 10 0.3 1000 10 1.0 20 1000 1.0 40 0.15 0.1 1.0 1.0 0.5 0.01 0.5 1.0 1.0 Into Sea () 6 =<3oC 6-9 80** 400 200 3500 10 0.3 SC*** 10 1.0 20 SC*** 1.0 40 0.15 0.1 1.0 1.0 0.5 0.01 0.5 1.0 1.0

25 26 27 28 29 30 31 32

Total Toxic metals Zinc Arsenic (4) Barium (4) Iron Manganese Boron (4) Chlorine

2.0 5.0 1.0 1.5 2.0 1.5 6.0 1.0

2.0 5.0 1.0 1.5 8.0 1.5 6.0 1.0

2.0 5.0 1.0 1.5 8.0 1.5 6.0 1.0

2.0 5.0 1.0 1.5 8.0 1.5 6.0 1.0

Explanations: 1. Assuming minimum dilution 1:10 on discharge, lower ratio would attract progressively stringent standards to be determined by the Federal Environmental Protection Agency. By 1:10 dilution means, for example that for each one cubic meter of treated effluent, the recipient water body should have 10 cubic meter of water for dilution of this effluent. Modified Benzene Alkyl Sulphate; assuming surfacetant as biodegradable. Pesticides include herbicides, fungicides and insecticides. Subject to total toxic metals discharge should not exceed level given at S. No. 25. Applicable only when and where sewage treatment is operational and BOD=80 mg/l is achieved by the sewage treatment system. Provided discharge is not at shore and not within 10 miles of mangrove or other important estuaries. The effluent should not result in temperature increase of more than 3oC at the edge of the zone where initial mixing and dilution take place in the receiving body. In case zone is not defined, use 100 meters from the point of discharge. The value for industry is 200 mg / l. Discharge concentration at or below sea concentration (SC). Dilution of liquied effluents to bring them to the NEQS limiting value is not permissible through fresh water mixing with the effluent before discharging into the environment. The concentration of pollutants in water being used will be subtracted from the effluent for calculating the NEQS limits.

2. 3. 4. 5.

6.

** ***

Note:- 1.

2.

You might also like