You are on page 1of 3

1900 Base Station Power Amplifier

TC-1900MCPA
Features
High downlink power of 52dBm for extended cell coverage. MCPA with 20MHz Instantaneous Bandwidth can support up multiple downlink carriers. Supports GSM, EDGE, CDMA and WCDMA signal. Low noise amplifier reduces uplink system noise figure and results in reduced call drops and improved voice quality. Reduces handset output power and improved BTS uplink receiver sensitivity. Permits local monitoring via PC at tower bottom and remotely by wireless modem. Alarms can be transmitted to OMC via data link or SMS. Automatic bypass feature permits BTS operation when PA or power supply fails. Internal Li-ion backup battery ensures alarm messages are transmitted when power is down. Designed for all outdoor installation waterproof, damp-proof and omni-sealed (IP54)

Product Description
TC-1900(MCPA) band-selective Base Station Power Amplifier provides both uplink and downlink amplification for multiple carriers and extends the coverage that decreases the cost and improves the service quality. The unit is fit for outdoor installation and can boost the transmitted power to extend cell coverage. The uplink low-noise amplifier (LNA) serves to improve the receiver sensitivity of the BTS to cope with the extended cell coverage in the downlink. The unit is powered by both AC and DC power supply options, including 110/220VAC and -48VDC. It consists of duplexers (DPX), uplink LNA, downlink MCPA, RF by-pass switch, Main Control Unit (MCU), distribution board, power supply unit (PSU), surge protector, wireless modem and Li-ion backup battery. Parameter settings can be done locally via a PC with installed OMT software, or remotely via wireless modem using OMT or OMC software. Through the wireless modem, the alarm data can be transmitted to the OMC automatically, or be sent as SMS to a predefined cellular device.

Functional Block Diagram

Downlink/Uplink By-pass

LNA1

BTS Ant 0

B T S

Tx /RXA
ATT

ANT

MCPA

TX /RXB
Rx1 Div

BTS Ant 1
LNA2

ANT1
Downlink/Uplink By-pass

Information contained in this document is subject to confirmation at time of ordering. http://www.comba-telecom.com

Issued:15Feb12 Control: 3-0-2 1/3

1900 Base Station Power Amplifier


TC-1900MCPA
Technical Specifications Electrical
Frequency Range, Uplink Frequency Range, Downlink Instantaneous Bandwidth Total Output Power Maximum Uplink Gain Maximum Downlink Gain In-band Intermodulation 9KHz to 1GHz Spurious (GSM) 1GHz to 12.75GHz f=885 kHz to 1.25 MHz Spurious (CDMA) f=1.25 MHz to 2.25 MHz f=2.25 MHz to 4 MHz f=2.515MHz to 2.715MHz Spurious (WCDMA) f= 2.715MHz to 3.515MHz f= 3.515MHz to 4MHz f= 4MHz to fmax Noise Figure, Uplink Absolute Maximum RF Input Power, Uplink Absolute Maximum RF Input Power, Downlink Insertion Loss, By-pass Mode Pass Band Ripple, p-p Input VSWR Impedance Dimensions, H x W x D Weight (approx.) Power Supply (Options) AC Power Consumption (approx.) Power Up Waiting Time (approx.) MCU Battery Backup Time (approx.) Enclosure Cooling RF Connectors Operating Temperature Operating Humidity EMC Environmental Class MTBF MHz MHz MHz dBm dB dB dBc dBm dBm dBc dBm dBm dBm dBm dBm dBm dB dBm dBm dB dB mm kg VAC VDC W sec hr 1850 1910 1930 1990 20 52 1 11 1 15 1 -60 -36/100KHz -30/1MHz -45/30kHz -9/30kHz -13/1MHz -14/30kHz -26/30kHz -26/30kHz -13/1MHz 3.0 10 46 1.5 1.5 1.5 50 620 x 588 x 240 49.5 90 265 / 47 63Hz -48 850W 180 3 Fan Din-F -25 to +50 95 ETSI EN 301 489-1 IP54 > 50,000 Note: Typical specification at room temperature

Power, Mechanical & Environmental

C %

hr

Information contained in this document is subject to confirmation at time of ordering. http://www.comba-telecom.com

Issued:15Feb12 Control: 3-0-2 2/3

1900 Base Station Power Amplifier


TC-1900MCPA
Operation and Maintenance
Using a direct serial connection to a PC, installation and commissioning of the TC-1900 is accomplished by the OMT. Using the integrated wireless modem (data or SMS mode), equipment parameters can be monitored and controlled remotely. Controlled equipment parameters include: Channel No, UL/DL ATT, Soft ON/OFF, Over-Temp Threshold, DL Output Power Threshold, DL Input Power Threshold and Alarm Report Enable. Monitored equipment alarms and parameters include: Alarms (LNA, DL PA, Power Down, PSU Fault, Door Open, DL Input Power Low, DL Output Power Low, and Over Temp), UL/DL Gain, DL Input /Output Power. The TC-1900 has been developed to take advantage of advanced network operation, where the OMC (optional) provides an effective solution for central monitoring of a group of Comba products.

Outline Drawing

620

568

240

Information contained in this document is subject to confirmation at time of ordering. http://www.comba-telecom.com

Issued:15Feb12 Control: 3-0-2 3/3

You might also like