MOTOR DATA SHEET : LT MOTOR 1 APPLICATION 2 TYPE OF COUPLING 3 FRAME SIZE 4 APPLICATION STANDARD 5 SERVICE 6 DUTY CYCLE 7 AMBIENT

TEMP. 8 RATED OUTPUT@50degree 9 TYPE OF MOTOR 10 RATED VOLTAGE and % variation range 11 RATED SPEED 12 RATED FREQUENCY and % variation range 13 FLC 14 NO LOAD POWER 15 RATED POWER FACTOR @ DIFFERENT LOADS : : : : : 16 EFFICIENCY AT RATED VOLTAGE & FREQUENCY i) At Full load ii) Three Quarter iii) 50% load 17 METHOD OF STARTING 18 STARTING CURRENT AT RATED VOLTAGE 19 STARTING TORQUE AT RATED VOLTAGE % FLT 20 PULL OUT TORQUE AT RATED VOLTAGE % FLT 21 STARTING TIME AT 80% 100% i) With Load ii)Without Load : : 8 SEC. / 6 SEC 6 SEC / 4 SEC. ( assuming load gd 2= motor gd2) : : : : : : : DOL 600% FLC 150% FLT 200 % FLT 94.00% 94.00% 92% 0.1-0.3 0.94 0.9 0.82 142 : : 3000 RPM 50Hz +/- 5% : : : : : : : : : : PRIMARY AIR FAN (BOILER) FIXED OR BELT PULLEY ND315M IS:12615 INDOOR CONTINUOUS , S1 50 DEGREE 90KW 3-PH SQUIRREL CAGE 415V +/- 10%

22 SAFE STALL TIME AT 110% VOLTAGE Cold Condition Hot Condition in Secs in Secs : : 12 24

23 SAFE STALL TIME AT 100% / 80% i)Cold condition ii)Hot Condition in Secs in Secs : : : : : 2 1 15/23 30/46

24 PERMISIBLE STARTS PER HOUR i) COLD ii)HOT 25 THERMAL TIME CONSTANT i) Heating ii) Cooling in Min in Min

: : : 2 minutes

60 120

26 PERMISIBLE RUNNING TIME AT FULL LOAD AT 75% OF RATED VOLTAGE 27 DEGREE OF PROTECTION 28 INSULATION CLASS (Temperature rise Class-B) over 45 degree ambient 29 WINDING CONNECTION 30 TYPE OF MOUNTING 31 LOAD GD2 i) Driven Equipement ii)Rotor iii)Total 32 MOTOR SHAFT (MATERIAL) 33 WEIGHT in KG

: :

IP55 F

: :

DELTA / MESH FOOT

: : : : : : : : : : : : : : Microns :

32 Kg m2 1.66 33.66 EN8

i)Stator with Winding ii)Rotor with winding iii)Total iv)Copper used in Motor 34 DIRECTION OF ROTATION 35 TOTAL GUARNTEED LOSSES COM IRON LOSS,FRICTION, WINDAGE & STRAY LOSSES I)Iron Loss ii)Cu Loss III)Friction ,windage &stray losses 36 PERMISSIBLE VIBRATION LIMITS

665 235 950 CANNOT BE FURNISHED BIDIRECTIONAL

FL EFFICIENCY W/O TOLERANCE SHALL BE 93.1% AS PER IS12075

37 MAGNETISING CURRENT TO MOTOR AT RATED Volt & Freq 38 MOTOR REACTANCE'S i) Sub transient ii)Transient iii)Steady state OHMS/PHASE

: : : : :

CANNOT BE FURNISHED

CANNOT BE FURNISHED FOR LT MOTORS CANNOT BE FURNISHED FOR LT MOTORS CANNOT BE FURNISHED FOR LT MOTORS

39 Details of extra precautions taken in motor design meet 150% of normal voltage during high speed Bus transfer

VPI & EPOXY GEL COAT ON WDG. OVERHANG

40 BEARING i)Make ii)Type iii)Recommended Lub. 41 MOTOR TERMINAL BOX i)Termination suitable ii)Fault with stand current 42 iii)Time for above fault current with stand 43 SPACE HEATER i) Nos & Location ii)Volts 44 iii)Watt per Heater 45 Characteristics i)Torque and Current as a function of Speed ii)PF & Eficiency as a function of Load iii)Time current & Thermal Limit curves on receipt of order on receipt of order on receipt of order : : 2 no. & on wdg. Overhang 240 V 60 W : : : 2X3C x 300 mm2 Aluminium 50 kA 0.25 sec. : : : SKF BALL LITHIUM BASE GREASE GRADE-II