You are on page 1of 8

Elite & Encore range

Encore and Elite are an exciting range of panel mounted, multi-functional, digital three phase CT/PT operated energy meters. They combine accuracy and versatility with various communication options. Encore and Elite offers cost effective performance for industrial and commercial metering segment.

Benefits
? An ideal replacement for analogue

Features
True Import only / Import-Export metering ?
? Accuracy class - 1.0 and 0.5s ? Accurate readings even at very low current 50mA to 6A for Ib=5A 10mA to 1.2A for Ib=1A ? Compact DIN 96 flush mounting meter ? User friendly, menu driven LCD display ? Favourite page for customized display ? On board diagnostics to report connection

ammeters and voltmeters


? Interface with external devices through

pulse I/O
? Compact and easy installation ? Most suited for online energy monitoring

systems
? Open circuit protection for CT Secondary

(optional)

faults
? Optical port for local and remote reading ? Optional unique CT shorting connector for

CT open circuit protection


? Metrology LED output configurable for

active, reactive and apparent energy


? Maximum demand integration period of 15,

30 or 60 minutes
? Power quality data display min / max

values of voltage, current, frequency and active power


? Pulse output for active energy ? User programmable setting of CT & VT

primary values

Elite & Encore range

Encore
Encore is a compact digital panel meter for measurement of power and energy parameters. It is ideal for sub-metering of distribution switchgear and connection to building management system. Encore provides advanced features for use in power transmission and distribution panels.

Elite
Elite is a compact digital panel meter to monitor electrical systems. It offers MODBUS on RS485 serial channel for remote interrogation of energy and instantaneous parameters. Elite is best suited to online energy monitoring systems and commercial and industrial sub-metering applications.

Elite Dual Register


Elite Dual register is provided with two separate registers for recording energy; the mains and DG supply. This is typically useful for commercial establishments, residential complexes and office spaces which have DG backup.

Secure Meters Limited


P.O. Box No. 30, E-Class Pratap Nagar Industrial Area, Udaipur 313003, INDIA T: 91-294-2492300-04 | F: 91-294-2492310 | E:mktg@securemeters.com | www.securemeters.com

Encore range

Encore is a 96x96 digital polyphase panel meter to measure power and energy parameters. It is an ideal replacement for analogue voltmeters, ammeters and energy meters. Encore has pulse output and other advanced features for use in control panels, relay panels and building management systems (BMS).

Features and Benefits


! True RMS measurement ! Accuracy class - 1.0 and 0.5s ! Metrology LED output configurable for active,

Parameters
Date & Time Power on/off hours Voltage L-N (V1, V2, V3) (for 3P4W only) Voltage L-L (V12,V23,V31) (for 3P3W and 3P4W both) Line current (L1, L2, L3) Neutral current Active / reactive current Phase wise power factor Average power factor Instantaneous active power Instantaneous reactive power Instantaneous apparent power Frequency RPM Active import energy kWh(I) Active forwarded energy kWh (F) Active export energy kWh (E) Reactive import energy kVARh(I) Reactive export energy kVARh(E) Apparent forwarded energy kVAh (F) Apparent energy kVAH Max min voltage phase wise Max line currents phase wise Max min frequency Min cap and Ind PF Max active power Max reactive power Max apparent power MD - Active MD - Apparent TOD

Models
SW1 SW2 SW3

reactive and apparent energy


! Accurate readings even at very low current 50mA to 6A for Ib=5A 10mA to 1.2A for Ib=5A ! LCD display with keypad ! Favourite page for customised display ! Fully type tested ! Tamper detection for PT miss, CT reversal, CT miss,

low PF, over voltage


! Auto scaling for Power / Energy (up to Giga) ! Advanced page mode display ! User programmable setting of CT & VT primary

values
! On board diagnostics for reporting connection

faults ! Optical port for local and remote reading


! Load profiling of 88 parameter days @ 30 min IP for

energy parameters
! Volts free pulse output for energy parameters

Load profiling Pulse output

kWh(I) kWh(I)

kWh(I) kWh(I)

kWh(I), kWh(E), kVAh, kVARh (I), kVARh(E)

kWh(I), kVARh(I)

Encore range
Technical specifications
Electrical Connection type Wiring configuration Voltage range Current range Overload Accuracy Main frequency Burden Approvals Standards Mechanical Dimensions (WXH) Cut out size Depth behind bezel Weight Enclosure Terminals Max conductor size Environmental Ingress protection Dielectric strength Temperature Humidity Features Favourite page CT/VT primary Communication Pulse output Display IP 50 (Front face) 1. Isolation: 2kV RMS, 50Hz | 2. Impulse withstand: 6kV -10 C to +55 C (operating) | -25 C to +70 C (storage) 95% non-condensing Configurable through keypad Programmable through keypad PACT port Voltage rating : 240 V | Current rating : 100 mA DC max Parameter : Configurable | Extra pulse output : On request Customised LCD display 96 x 96 mm 92 x 92 mm 84mm 650gms Extruded aluminium Combicon connector 2.5 mm2 CT operated, CT / PT operated LT (3P4W), HT (3P3W, 3P4W) LT: 240V (L-N) 415V (L-L) HT: 63.5V (L-N), 110V (L-L) 1-1.2A (Starting :1mA);5-6A(Starting: 5mA) Confirms class of accuracy up to 120%Ib continuous Withstand up to 130% Imax continuous | 20 X Imax for 0.5 sec Class 0.5s,1.0 50Hz 5% Voltage circuit- <1.5W, <1VA Current circuit- <0.5VA IS14697, IS13779 IEC 62052-11, IEC 62053-21, 22, 23

Secure Meters Limited


P.O. Box No. 30, E-Class Pratap Nagar Industrial Area, Udaipur 313003, INDIA T: 91-294-2492300-04 | F: 91-294-2492310 | E:mktg@securemeters.com | www.securemeters.com

Specifications are subject to change without prior notice

Elite range

Elite is a 96x96 panel mounted polyphase digital energy meter. It provides multi-functional metering and online monitoring solution through MODBUS RS485. Elite is suitable for various applications like high voltage and low voltage switchgear panels, control and relay panels and online energy monitoring systems (SCADA/ EMS/ DAS).

Features and Benefits


! ! ! ! !

Compact DIN 96 flush mounting panel meter True RMS measurement Four quadrant metering Accuracy class - 1.0, 0.5s, 0.2s. Metrology LED output configurable for active, reactive and apparent energy Accurate readings even at very low current
50mA to 6A for Ib=5A 10mA to 1.2A for Ib=1A

Parameters
Voltage L-N (V1, V2, V3) ( for 3P4W only) Voltage L-L (V12,V23,V31) (for 3P3W and 3P4W) Line currents (L1, L2, L3) Neutral current Active / Reactive currents (I1, I2, I3 / i1, i2, i3) Active power three phase Reactive power three phase Apparent power three phase Power factor (R, Y, B) Power factor three phase average Voltage phase angles (RY, RB) Frequency MODBUS on RS485 4 channel 4-20mA output Date / Time Cumm on hours Cumm off hours RPM Running time above threshold Power interruption count Active import energy kWh(I) Active export energy kWh(E) Reactive lag while active import energy-Q1 Reactive lead while active export energy-Q2 Reactive lag while active export energy-Q3 Reactive lead while active import energy-Q4 Apparent while active import energy- kVAh (I) Apparent while active export energy kVAh (E) MD (kW and kVA) MD kW and kVA Occurrence time Rising demand with elapsed time Load survey TOD 2 billing histories Max min voltage phase wise Max line currents phase wise Min cap and Ind PF Max min frequency Max active reactive and apparent power Pulse Input / Output In built CT shorting connector

Models
111 112 113 114 115 120 130

! ! ! ! ! !

Auto scaling for power / energy (up to Giga) Auto scrolling of favourite page parameters Password protection for setup mode. Fully type tested Field configurable CT / PT primary values through push button Tamper detection for PT miss, CT reversal, CT miss, low PF, over voltage Backlit LCD display with keypad Advanced page mode display Favourite page for customised display Support of MODBUS RTU on RS485 Support of Hexadecimal or Floating point format (as per IEEE 754) on MODBUS 4 channel 4-20mA pulse outputs Optical port for local and remote reading Optional Auxiliary power Supply (80-300V AC/DC or 24-60V DC) Time of day metering Optional CT shorting plug for open circuit protection Three pulse inputs Two volt free pulse outputs 2 history data support Load Profiling for 30 days @ 30 min IP for three energy parameters kWh(I), kVARh Lag while kWh(I)-Q1, kVAh (I) On board diagnostics for reporting connection faults

! ! ! ! !

o o o

! ! ! ! ! ! ! ! !

o o o o

( ): Standard; (o) : Optional to ( be specify, while ordering) (*) : Equivalent models 101, 102, 103, 104, 105 are also available without MODBUS on RS485

Elite range
Technical specifications
Electrical Connection type Wiring configuration Voltage range Current range Overload Accuracy Main frequency Burden Power supply CT operated, CT/PT operated LT (3P4W), HT (3P3W, 3P4W) LT: 240V (L-N) 415V (L-L) | HT: 63.5V (L-N), 110V (L-L) 1-1.2A (Starting :1mA); 5-6A(Starting: 5mA) Confirms class of accuracy up to 120%Ib continuous Withstand up to 130% Imax continuous | 20 X Imax for 0.5 sec Class 0.2s,0.5s,1.0 50Hz 5% Voltage circuit- <1.5W, <1VA | Current circuit- <0.5VA | Auxiliary supply- <3VA
Self powered (-30% to +20% Vb) Auxiliary supply 24-60V DC | 80-300V AC/DC

Approvals Standards Mechanical Dimensions (WXH) Cut out size Depth behind bezel Weight Enclosure Terminals Max conductor size Environmental Ingress protection Dielectric strength Temperature Humidity Features Display Favourite page CT/VT primary Communication Baud rate (MODBUS Port) Analogue outputs Pulse output Pulse input Customised backlit LCD display Configurable through keypad Configurable in field through keypad PACT port, MODBUS on RS485 1200, 2400, 4800, 9600, 19200bps (configurable in field through keypad) 4 channel 4-20mA output- can be factory configured for instantaneous parameters like Voltage, Current, Power, Frequency and Power factor Voltage rating: 240 V | Current rating: 100 mA DC max | Parameter: Configurable Voltage rating: 12-40V DC | Current rating: 100 mA DC max
Specifications are subject to change without prior notice

IS14697, IS13779 | IEC 62052-11, IEC 62053-21, 22, 23 96 x 96 mm 92 x 92 mm 84mm 400gms Poly carbonate Combicon connector 2.5 mm2 IP 50 (Front face) 1. Isolation: 4kV RMS, 50Hz | 2. Impulse withstand: 6kV -10 C to +55 C (operating) | -25 C to +70 C (storage) 95% non-condensing

Secure Meters Limited


P.O. Box No. 30, E-Class Pratap Nagar Industrial Area, Udaipur 313003, INDIA T: 91-294-2492300-04 | F: 91-294-2492310 | E:mktg@securemeters.com | www.securemeters.com

Elite 200 | Elite 210

Elite 200 series is specially designed for dual source energy metering. It provides two separate registers for recording energy; mains and DG supply. Elite Dual Register also offers load control solutions whereby a consumer can be disconnected if load exceeds a certain limit.

Elite 210 additionally provides data on MODBUS RT U o ve r R S 485 f o r o n l i n e m o n i to r i ng applications.

Features and Benefits


! ! ! ! ! ! ! ! ! ! ! !

! ! ! ! ! ! ! !

! ! ! ! !

Compact DIN 96 flush mounting panel meter Accuracy class - 1.0 and 0.5s Backlit LCD display with key pad Favourite page for customised display Bi-vector energy measurement Separate energy registration for mains and DG supply Forward energy registration in case of current reversal Auto scaling for Power / Energy (up to Giga) Auto scrolling of favourite page parameters Password protection for setup mode. Fully type tested Accurate readings even at very low current 50mA to 6A for Ib=5A 10mA to 1.2A for Ib=1A One pulse input with option of AC / DC for switching of metering between Mains & DG One pulse output for load control (load monitoring based on last minute average load) Power On / Off hours for mains and DG supply Time of day metering Load profiling for 60 parameter days @30 min IP MD registers for active and apparent Two history data support RS485 MODBUS data formats Floating point (as per IEEE-754) or Hexadecimal format Self diagnostic displays for connection check Meter configuration through push button On board diagnostics for reporting connection faults User programmable setting of CT & VT primary values Optical port for local and remote reading

Parameters
Voltage L-N (V1, V2, V3) Line currents (L1, L2, L3) Active power three phase Apparent power three phase Power factor (R, Y, B) Power factor three phase average Frequency MODBUS on RS485 Date / Time Cumm on hours Cumm off hours Cumm on hours-DG Cumm off hours-DG Active forwarded energy kWh(F)-Mains Active forwarded energy kWh(F)-DG Apparent forwarded energy kVAh (F)-Mains Apparent forwarded energy kVAh (F)-DG MD (kW and kVA) Mains MD kW and kVA occurrence time Load averaging time Load limit-Mains Load limit-DG Load survey TOD 2 billing histories

Models
200 210

Elite 200 | Elite 210


Technical specifications
Electrical Connection type Wiring configuration Voltage range Current range Overload Accuracy Main frequency Burden Approvals Standards Mechanical Dimensions (WXH) Cut out size Depth behind bezel Weight Enclosure Terminals Max conductor size Environmental Ingress protection Dielectric strength Temperature Humidity Features Display Favourite page CT/VT primary Communication Baud rate (MODBUS) Pulse output (for Load Control) Pulse input Customised backlit LCD display Configurable through keypad Programmable through keypad PACT port, optional MODBUS on RS485 1200, 2400, 4800, 9600, 19200bps (field configurable through keypad) Voltage rating: 240V AC | Current rating: 100 mA DC max Voltage rating: Variants for 12-40V DC or 60-240V AC | Current rating: 100 mA DC max IP 50 (Front Face) 1. Isolation: 4kV RMS, 50Hz | 2. Impulse withstand: 6kV -10 C to +55 C (operating) | -25 C to +70 C (storage) 95% non-condensing 96 x 96 92 x 92 mm 84mm 400 gms Poly carbonate Combicon connector 2.5 mm2 IS14697, IS13779 | IEC 62052-11, IEC 62053-21, 22, 23 CT operated 3P4W 240V(L-N) 415V(L-L) 1-1.2A (Starting :1mA); 5-6A(Starting: 5mA) Confirms class of accuracy up to 120%Ib continuous Withstand up to 130% Imax continuous, 20 X Imax for 0.5 sec Class 0.5s, 1.0 50 Hz 5% Voltage circuit- <1.5W & 1VA | Current circuit- <0.5VA

Secure Meters Limited


P.O. Box No. 30, E-Class Pratap Nagar Industrial Area, Udaipur 313003, INDIA T: 91-294-2492300-04 | F: 91-294-2492310 | E:mktg@securemeters.com | www.securemeters.com

Specifications are subject to change without prior notice