You are on page 1of 543

Accessibility Survey

Americans with Disabilities Act


And
Title 24 of the California Building Code

San Joaquin
County Fairgrounds
Prepared By
WORKING DRAFT
Disability Access Consultants, Inc.
(800) 743-7067
1658 S. Airport Way
Stockton, CA
Facility Name: San Joaquin Fairgrounds

Programs, Services, and Activities


Finding: The San Joaquin Fairgrounds, located at 1658 South Airport
Way in Stockton California, was inspected by Disability Access
Consultants, Inc., on May 8 and 9, 2006.

Alternative *
Rec:
(Where
Available)

Full Rec Any renovation or new construction that occurred after January Citation ADAAG 4.1.2; ADAAG 4.1.3; ADAAG 4.1.5;
26, 1992, is subject to meet full code specifications for the ADAAG 4.1.6
California Building Code and ADAAG requirements. All
recommendations in this report are based on ADAAG and CBC Minimum Quantity 1
title 24 requirements. Consult with your design professional to Maximum Quantity: 1
determine which elements are affected by these requirements.
It is recommended that Disability Access Consultants, Inc. is Unit: None Selected
consulted for inspection of any new construction or renovation at Minimum Estimated Cost: 0
the facility.
Maximum Estimated Cost: 0
Record Number 103
Priority:

Parking
Finding: There are seven parking lots provided at the facility. The paved
parking lots are located outside of the main entrance gate,
outside of the Winners Gaming and Sports Emporium, outside
of Buildings 1, 2, 4 and 6 thru 8, outside of Flates BBQ, next to
the Horse Barns, next to the soccer field and outside of the
Maintenance Shop.

Alternative *
Rec:
(Where
Available)

Full Rec Accessible paved parking spaces shall be located on the Citation CBC 1129B; ADAAG 4.3.2(1); ADAAG 4.14.1
shortest accessible route of travel to the facility and shall
coincide with the primary route and primary entrances used by
the general public (see CBC 1129B.4, ADAAG 4.3.2(1) and Minimum Quantity 1
ADAAG 4.14.1). Maximum Quantity: 1
Unit: None Selected
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 104
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 1 of 542


Facility Name: San Joaquin Fairgrounds
Parking
Finding: Parking is provided off-street to the public and/or employees
outside of Buildings 1, 2, 4 and 6 thru 8, though no marked
spaces are provided.

Alternative *
Rec:
(Where
Available)

Parking Lot Outside of Buildings 1, 2, 4 and 6 thru 8

Full Rec Stripe parking spaces with an appropriate number of accessible Citation CBC 1129B; ADAAG 4.6
parking spaces designated to comply with CBC 1129B and
ADAAG 4.6. Accessible parking spaces shall be located on the
shortest accessible route of travel to the facility for which it Minimum Quantity 1
serves and shall coincide with the primary route and entrances Maximum Quantity: 1
used by the general public (see CBC 1129B and ADAAG
4.3.2(1). The access aisle and route to the primary facility Unit: Custom
entrance shall also be of an accessible surface. Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 113
Priority:

Parking
Finding: Each designated accessible parking space required in the
parking lot shall provide a post-mounted sign showing the
International Symbol of Accessibility.

Alternative *
Rec:
(Where
Available)

Parking Lot Outside of Buildings 1, 2, 4 and 6 thru 8

Full Rec Install a permanently posted reflectorized sign measuring 70 Citation CBC 1129B.5; ADAAG 4.6.4
square inches that includes an ISA symbol adjacent to and
visible from each accessible parking space (see CBC 1129B.5).
The bottom edge of each sign must be mounted 80 inches from Minimum Quantity 1
the ground surface so that it cannot be obscured by a parked Maximum Quantity: 1
vehicle (see CBC 1129B.5). The van-accessible parking space
shall provide an additional sign marked "van-accessible" Unit: Each
mounted below the sign (see CBC 1129B.5 and ADAAG 4.6.4). Minimum Estimated Cost: 150
Maximum Estimated Cost: 150
Record Number 114
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 2 of 542


Facility Name: San Joaquin Fairgrounds
Parking
Finding: There is no warning signage posted at the entrance to the
parking lot regarding unauthorized use of accessible parking
spaces in the parking lot.

Alternative *
Rec:
(Where
Available)

Parking Lot Outside of Buildings 1, 2, 4 and 6 thru 8

Full Rec Post a sign in a conspicuous place to the entrance of the Citation CBC 1129B.5; ADAAG 4.6.4 CVC 22511.8(a)(d)
parking lot, or immediately adjacent to and visible from each
accessible parking space. The warning sign shall measure at
least 17 inches by 22 inches in size and consist of lettering at Minimum Quantity 1
least 1 inch in height that clearly and conspicuously states the Maximum Quantity: 1
following; "Unauthorized vehicles parked in designated
accessible spaces not displaying distinguishing placards or Unit: Each
license plates issued for persons with disabilities may be towed Minimum Estimated Cost: 150
away at owner's expense. Towed vehicles may be reclaimed
at ____ or by telephoning ___ ." Fill in the blank spaces Maximum Estimated Cost: 150
with appropriate information as a permanent part of the sign and Record Number 115
maintain the currency of the information (see CBC 1129B.5). Priority:

Parking
Finding: Paved parking is provided outside of Flats BBQ. There are no
accessible parking spaces designated out of 17 total parking
spaces provided in the parking lot.

Alternative *
Rec:
(Where
Available)

Parking Lot Outside of Flats BBQ

Full Rec One out of the 17 total number of marked parking spaces is Citation CBC 1129B; ADAAG 4.3.2(1); ADAAG 4.6.2;
required to be designated exclusively for accessible parking, as ADAAG 4.1.2(5)
required by CBC 1129B and ADAAG. Create one van-
accessible parking space measuring at least 108 inches wide Minimum Quantity 1
and 216 inches long with an access aisle measuring at least 96 Maximum Quantity: 1
inches wide (8 feet) located on the passenger side (right side) of
the parking space (see CBC 1129B). Add the words NO Unit: Each
PARKING in 12 inch high white letters at the entrance to the Minimum Estimated Cost: 270
accessible parking access aisle.
Maximum Estimated Cost: 270
Record Number 116
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 3 of 542


Facility Name: San Joaquin Fairgrounds
Parking
Finding: The designated accessible parking space required in the
parking lot shall provide a post-mounted sign showing the
International Symbol of Accessibility.

Alternative *
Rec:
(Where
Available)

Parking Lot Outside of Flats BBQ

Full Rec Install a permanently posted reflectorized sign measuring 70 Citation CBC 1129B.5; ADAAG 4.6.4
square inches that includes an ISA symbol adjacent to and
visible from the accessible parking space (see CBC 1129B.5).
The bottom edge of the sign must be mounted 80 inches from Minimum Quantity 1
the ground surface so that it cannot be obscured by a parked Maximum Quantity: 1
vehicle (see CBC 1129B.5). The "van-accessible" parking
space shall provide an additional sign marked "van-accessible" Unit: Each
mounted below the sign (see CBC 1129B.5 and ADAAG 4.6.4). Minimum Estimated Cost: 150
Maximum Estimated Cost: 150
Record Number 117
Priority:

Parking
Finding: There is no warning signage posted at the entrance to the
parking lot regarding unauthorized use of accessible parking
spaces in the parking lot.

Alternative *
Rec:
(Where
Available)

Parking Lot Outside of Flats BBQ

Full Rec Post a sign in a conspicuous place to the entrance of the Citation CBC 1129B.5; ADAAG 4.6.4 CVC 22511.8(a)(d)
parking lot, or immediately adjacent to and visible from each
accessible parking space. The warning sign shall measure at
least 17 inches by 22 inches in size and consist of lettering at Minimum Quantity 1
least 1 inch in height that clearly and conspicuously states the Maximum Quantity: 1
following; "Unauthorized vehicles parked in designated
accessible spaces not displaying distinguishing placards or Unit: Each
license plates issued for persons with disabilities may be towed Minimum Estimated Cost: 150
away at owner's expense. Towed vehicles may be reclaimed
at ____ or by telephoning ___ ." Fill in the blank spaces Maximum Estimated Cost: 150
with appropriate information as a permanent part of the sign and Record Number 118
maintain the currency of the information (see CBC 1129B.5). Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 4 of 542


Facility Name: San Joaquin Fairgrounds
Parking
Finding: There are 14 accessible parking spaces provided. Each
accessible parking space provided measures at least 108
inches wide and 216 inches long. The two van-accessible
parking spaces each provide an access aisle, located on the
passenger side of the parking space, measuring 96 inches
wide. Two of the standard accessible parking spaces provide
an adjacent access aisle measuring 95 inches wide. There is
no access aisle provided adjacent to ten of the standard
accessible parking spaces. The access aisles do not contain
"NO PARKING" in 12" high white letters
Alternative *
Rec:
(Where
Available)

Parking Lot Outside of the Main Entrance Gate

Full Rec Fourteen parking spaces meets the number required to be Citation CBC 1129B; ADAAG 4.6; ADAAG A4.6
designated exclusively for accessible parking according to
ADAAG and CBC 1129B. Restripe the designated accessible
parking spaces to create two van-accessible and 12 standard Minimum Quantity 1
accessible parking space, each measuring at least 108 inches Maximum Quantity: 1
wide and 216 inches long. The van-accessible spaces shall
provide an access aisle measuring at least 96 inches wide (8 Unit: Each
feet) on the passenger side (right side) of the vehicle space (see Minimum Estimated Cost: 270
CBC 1129B). The additional parking spaces shall each provide
an access aisle measuring at least 60 inches wide, that may be Maximum Estimated Cost: 270
shared. Add the words NO PARKING in 12 inch high white Record Number 106
letters at the entrance to each accessible parking access aisle. Priority:

Parking
Finding: There is no crosswalk provided on the path of travel from the
accessible parking spaces to the facility. The required
accessible route crosses a vehicular way.

Alternative *
Rec:
(Where
Available)

Parking Lot Outside of the Main Entrance Gate

Full Rec Stripe a crosswalk not less than 48 inches wide on the path of Citation ADAAG 4.7.9
travel to the accessible entrance. Provide a level surface that
does not exceed a slope greater than 5%. Cross slopes shall
not exceed 2%. Detectable warnings should be placed at the Minimum Quantity 1
entrance and exit of the crosswalk. Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 100
Maximum Estimated Cost: 100
Record Number 107
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 5 of 542


Facility Name: San Joaquin Fairgrounds
Parking
Finding: There is no vertically-mounted signage at the designated
accessible parking spaces in the parking lot showing the
International Symbol of Accessibility. There is no additional
signage marked "van-accessible" at the van-accessible parking
spaces.

Alternative *
Rec:
(Where
Available)

Parking Lot Outside of the Main Entrance Gate

Full Rec Install a permanently posted reflectorized sign measuring 70 Citation CBC 1129B.5; ADAAG 4.6.4
square inches that includes an ISA symbol adjacent to and
visible from each accessible parking space (see CBC 1129B.5).
The bottom edge of the sign must be mounted 80 inches from Minimum Quantity 1
the ground surface so that it cannot be obscured by a parked Maximum Quantity: 1
vehicle (see CBC 1129B.5). The "van-accessible" parking
space shall provide an additional sign marked "van-accessible" Unit: Each
mounted below the sign (see CBC 1129B.5 and ADAAG 4.6.4). Minimum Estimated Cost: 150
Maximum Estimated Cost: 150
Record Number 108
Priority:

Parking
Finding: There is no warning signage posted at the entrance to the
parking lot regarding unauthorized use of accessible parking
spaces in the parking lot.

Alternative *
Rec:
(Where
Available)

Parking Lot Outside of the Main Entrance Gate

Full Rec Post a sign in a conspicuous place to the entrance of the Citation CBC 1129B.5; ADAAG 4.6.4 CVC 22511.8(a)(d)
parking lot, or immediately adjacent to and visible from each
accessible parking space. The warning sign shall measure at
least 17 inches by 22 inches in size and consist of lettering at Minimum Quantity 1
least 1 inch in height that clearly and conspicuously states the Maximum Quantity: 1
following; "Unauthorized vehicles parked in designated
accessible spaces not displaying distinguishing placards or Unit: Each
license plates issued for persons with disabilities may be towed Minimum Estimated Cost: 150
away at owner's expense. Towed vehicles may be reclaimed
at ____ or by telephoning ___ ." Fill in the blank spaces Maximum Estimated Cost: 150
with appropriate information as a permanent part of the sign and Record Number 109
maintain the currency of the information (see CBC 1129B.5). Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 6 of 542


Facility Name: San Joaquin Fairgrounds
Parking
Finding: Parking is provided off-street to the public and/or employees
outside of the Maintenance Shop, though the parking lot surface
is gravel and nonaccessible.

Alternative *
Rec:
(Where
Available)

Parking Lot Outside of the Maintenance Shop

Full Rec Pave the parking lot and stripe parking spaces with an Citation CBC 1129B; ADAAG 4.6
appropriate number of accessible parking spaces designated to
comply with CBC 1129B and ADAAG 4.6.
Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 125
Priority:

Parking
Finding: There is signage designating one nonaccessible parking space
as accessible. The designated accessible parking space
required in the parking lot shall provide a post-mounted sign
showing the International Symbol of Accessibility.

Alternative *
Rec:
(Where
Available)

Parking Lot Outside of the Maintenance Shop

Full Rec Remove the signage designating the nonaccessible parking Citation CBC 1129B.5; ADAAG 4.6.4
space as accessible. Install a permanently posted reflectorized
sign measuring 70 square inches that includes an ISA symbol
adjacent to and visible from the accessible parking space (see Minimum Quantity 1
CBC 1129B.5). The bottom edge of the sign must be mounted Maximum Quantity: 1
80 inches from the ground surface so that it cannot be obscured
by a parked vehicle (see CBC 1129B.5). The van-accessible Unit: Each
parking space shall provide an additional sign marked "van- Minimum Estimated Cost: 150
accessible" mounted below the sign (see CBC 1129B.5 and
ADAAG 4.6.4). Maximum Estimated Cost: 150
Record Number 126
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 7 of 542


Facility Name: San Joaquin Fairgrounds
Parking
Finding: There is no warning signage posted at the entrance to the
parking lot regarding unauthorized use of accessible parking
spaces in the parking lot.

Alternative *
Rec:
(Where
Available)

Parking Lot Outside of the Maintenance Shop

Full Rec Post a sign in a conspicuous place to the entrance of the Citation CBC 1129B.5; ADAAG 4.6.4 CVC 22511.8(a)(d)
parking lot, or immediately adjacent to and visible from each
accessible parking space. The warning sign shall measure at
least 17 inches by 22 inches in size and consist of lettering at Minimum Quantity 1
least 1 inch in height that clearly and conspicuously states the Maximum Quantity: 1
following; "Unauthorized vehicles parked in designated
accessible spaces not displaying distinguishing placards or Unit: Each
license plates issued for persons with disabilities may be towed Minimum Estimated Cost: 150
away at owner's expense. Towed vehicles may be reclaimed
at ____ or by telephoning ___ ." Fill in the blank spaces Maximum Estimated Cost: 150
with appropriate information as a permanent part of the sign and Record Number 127
maintain the currency of the information (see CBC 1129B.5). Priority:

Parking
Finding: There are 12 accessible parking spaces out of 344 parking
spaces which is sufficient in number as required for compliance.

Alternative *
Rec:
(Where
Available)

Parking Lot Outside of the Winners Gaming and Sports


Emporium

Full Rec Twelve out of the 344 total number of marked parking spaces Citation CBC 1129B; ADAAG 4.6; ADAAG A4.6
meets the number required to be designated exclusively for
accessible parking according to ADAAG and CBC 1129B.
Minimum Quantity 1
Maximum Quantity: 1
Unit: None Selected
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 110
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 8 of 542


Facility Name: San Joaquin Fairgrounds
Parking
Finding: Parking Continued: Two of the accessible parking spaces
measure less than 108 inches wide and at least 216 inches
long. Ten of the accessible parking spaces measure at least
108 inches wide and 216 inches long. The van-accessible
parking space provides an access aisle, located on the
passenger side of the vehicle space, measuring at least 96
inches wide. Each standard accessible parking space provides
an adjacent access aisle measuring 60 inches wide. The
access aisles do not contain "NO PARKING" in 12" high white
letters
Alternative *
Rec:
(Where
Available)

Parking Lot Outside of the Winners Gaming and Sports


Emporium

Full Rec Restripe the designated accessible parking spaces to create Citation CBC 1129B; ADAAG 4.6; ADAAG A4.6
one van-accessible and one standard accessible parking space,
each measuring at least 108 inches wide and 216 inches long
with an access aisle measuring at least 96 inches wide (8 feet) Minimum Quantity 1
shared between the two accessible parking spaces (see CBC Maximum Quantity: 1
1129B). The accessible parking space with the access aisle to
the right of the space shall be designated "van-accessible." Add Unit: Each
the words NO PARKING in 12 inch high white letters at the Minimum Estimated Cost: 270
entrance to each accessible parking access aisle.
Maximum Estimated Cost: 270
Record Number 111
Priority:

Parking
Finding: There is no warning signage posted at the entrance to the
parking lot regarding unauthorized use of accessible parking
spaces in the parking lot.

Alternative *
Rec:
(Where
Available)

Parking Lot Outside of the Winners Gaming and Sports


Emporium

Full Rec Post a sign in a conspicuous place to the entrance of the Citation CBC 1129B.5; ADAAG 4.6.4 CVC 22511.8(a)(d)
parking lot, or immediately adjacent to and visible from each
accessible parking space. The warning sign shall measure at
least 17 inches by 22 inches in size and consist of lettering at Minimum Quantity 1
least 1 inch in height that clearly and conspicuously states the Maximum Quantity: 1
following; "Unauthorized vehicles parked in designated
accessible spaces not displaying distinguishing placards or Unit: Each
license plates issued for persons with disabilities may be towed Minimum Estimated Cost: 150
away at owner's expense. Towed vehicles may be reclaimed
at ____ or by telephoning ___ ." Fill in the blank spaces Maximum Estimated Cost: 150
with appropriate information as a permanent part of the sign and Record Number 112
maintain the currency of the information (see CBC 1129B.5). Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 9 of 542


Facility Name: San Joaquin Fairgrounds
Parking
Finding: Parking is provided off-street to the public next to the Horse
Barns, though the parking lot surface is gravel and
nonaccessible. The parking lot can provide approximately 40
parking spaces.

Alternative *
Rec:
(Where
Available)

RV Parking Lot Next to the Horse Barns

Full Rec Pave the parking lot and stripe parking spaces with an Citation CBC 1129B; ADAAG 4.6
appropriate number of accessible parking spaces designated to
comply with CBC 1129B and ADAAG 4.6.
Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 119
Priority:

Parking
Finding: Each designated accessible parking space required in the
parking lot shall provide a post-mounted sign showing the
International Symbol of Accessibility.

Alternative *
Rec:
(Where
Available)

RV Parking Lot Next to the Horse Barns

Full Rec Install a permanently posted reflectorized sign measuring 70 Citation CBC 1129B.5; ADAAG 4.6.4
square inches that includes an ISA symbol adjacent to and
visible from each accessible parking space (see CBC 1129B.5).
The bottom edge of each sign must be mounted 80 inches from Minimum Quantity 1
the ground surface so that it cannot be obscured by a parked Maximum Quantity: 1
vehicle (see CBC 1129B.5). The "van-accessible" parking
space shall provide an additional sign marked "van-accessible" Unit: Each
mounted below the sign (see CBC 1129B.5 and ADAAG 4.6.4). Minimum Estimated Cost: 150
Maximum Estimated Cost: 150
Record Number 120
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 10 of 542


Facility Name: San Joaquin Fairgrounds
Parking
Finding: There is no warning signage posted at the entrance to the
parking lot regarding unauthorized use of accessible parking
spaces in the parking lot.

Alternative *
Rec:
(Where
Available)

RV Parking Lot Next to the Horse Barns

Full Rec Post a sign in a conspicuous place to the entrance of the Citation CBC 1129B.5; ADAAG 4.6.4 CVC 22511.8(a)(d)
parking lot, or immediately adjacent to and visible from each
accessible parking space. The warning sign shall measure at
least 17 inches by 22 inches in size and consist of lettering at Minimum Quantity 1
least 1 inch in height that clearly and conspicuously states the Maximum Quantity: 1
following; "Unauthorized vehicles parked in designated
accessible spaces not displaying distinguishing placards or Unit: Each
license plates issued for persons with disabilities may be towed Minimum Estimated Cost: 150
away at owner's expense. Towed vehicles may be reclaimed
at ____ or by telephoning ___ ." Fill in the blank spaces Maximum Estimated Cost: 150
with appropriate information as a permanent part of the sign and Record Number 121
maintain the currency of the information (see CBC 1129B.5). Priority:

Parking
Finding: Parking is provided off-street to the public next to the soccer
field, though the parking lot surface is gravel and
nonaccessible. The parking lot can provide approximately 66
parking spaces.

Alternative *
Rec:
(Where
Available)

RV Parking Lot Next to the Soccer Field

Full Rec Pave the parking lot and stripe parking spaces with an Citation CBC 1129B; ADAAG 4.6
appropriate number of accessible parking spaces designated to
comply with CBC 1129B and ADAAG 4.6.
Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 122
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 11 of 542


Facility Name: San Joaquin Fairgrounds
Parking
Finding: There is signage designating two of the nonaccessible parking
spaces as accessible. Each designated accessible parking
space required in the parking lot shall provide a post-mounted
sign showing the International Symbol of Accessibility.

Alternative *
Rec:
(Where
Available)

RV Parking Lot Next to the Soccer Field

Full Rec Remove the signage designating the nonaccessible parking Citation CBC 1129B.5; ADAAG 4.6.4
spaces. Install a permanently posted reflectorized sign
measuring 70 square inches that includes an ISA symbol
adjacent to and visible from each accessible parking space (see Minimum Quantity 1
CBC 1129B.5). The bottom edge of each sign must be Maximum Quantity: 1
mounted 80 inches from the ground surface so that it cannot be
obscured by a parked vehicle (see CBC 1129B.5). The "van- Unit: Each
accessible" parking space shall provide an additional sign Minimum Estimated Cost: 150
marked "van-accessible" mounted below the sign (see CBC
1129B.5 and ADAAG 4.6.4). Maximum Estimated Cost: 150
Record Number 123
Priority:

Parking
Finding: There is no warning signage posted at the entrance to the
parking lot regarding unauthorized use of accessible parking
spaces in the parking lot.

Alternative *
Rec:
(Where
Available)

RV Parking Lot Next to the Soccer Field

Full Rec Post a sign in a conspicuous place to the entrance of the Citation CBC 1129B.5; ADAAG 4.6.4 CVC 22511.8(a)(d)
parking lot, or immediately adjacent to and visible from each
accessible parking space. The warning sign shall measure at
least 17 inches by 22 inches in size and consist of lettering at Minimum Quantity 1
least 1 inch in height that clearly and conspicuously states the Maximum Quantity: 1
following; "Unauthorized vehicles parked in designated
accessible spaces not displaying distinguishing placards or Unit: Each
license plates issued for persons with disabilities may be towed Minimum Estimated Cost: 150
away at owner's expense. Towed vehicles may be reclaimed
at ____ or by telephoning ___ ." Fill in the blank spaces Maximum Estimated Cost: 150
with appropriate information as a permanent part of the sign and Record Number 124
maintain the currency of the information (see CBC 1129B.5). Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 12 of 542


Facility Name: San Joaquin Fairgrounds
Passenger Loading Zones
Finding: There is no required striped access aisle adjacent to the
passenger loading zone. There is no signage designating
accessibility posted at the passenger loading zone.

Alternative *
Rec:
(Where
Available)

Passenger Loading Zone Outside of the Winners Emporium

Full Rec Stripe an access aisle at least 5 feet (60 inches) wide and 20 Citation CBC 1131B; ADAAG 4.6.6; ADAAG 4.1.2(7)(b)
feet (240 inches) long adjacent and parallel to the vehicle pull-up
space. The access aisle striping for the passenger loading zone
shall provide immediate access to the adjacent curb ramp. Post Minimum Quantity 1
signage designating the passenger loading zone as accessible Maximum Quantity: 1
(see CBC 1131B and ADAAG 4.1.2(7)(b)). The sign should
contain the International Symbol of Accessibility. Unit: Each
Minimum Estimated Cost: 300
Maximum Estimated Cost: 300
Record Number 128
Priority:

Curb Ramps
Finding: The slope of the top landing is greater than 2%. The concrete
curb ramp does not provide a detectable warning surface which
includes truncated domes.

Alternative *
Rec:
(Where
Available)

Curb Ramp at the Winners Gaming and Sports Emporium


Main Entrance

Full Rec Replace the curb ramp with a compliant curb ramp at least 48 Citation CBC 1127B.5.3; ADAAG 4.7.2 & 4.29
inches in width that provides a slope no greater than 8.33%.
Install a detectable warning surface which extends the full length
and width of the concrete curb ramp and its side flares with Minimum Quantity 1
truncated domes that contrast visually by either light on dark or Maximum Quantity: 1
dark on light which is an integral part of the concrete curb ramp.
The truncated domes may be cast in place or stamped or of a Unit: Each
prefabricated surface treatment (see CBC 1127B.5.8). Minimum Estimated Cost: 1033
Maximum Estimated Cost: 1033
Record Number 131
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 13 of 542


Facility Name: San Joaquin Fairgrounds
Curb Ramps
Finding: The built-up curb ramp projects into vehicular traffic and
interferes with individuals entering or exiting parked or standing
vehicles. The slope of the curb ramp is greater than 8.33%.
The curb ramp does not provide a grooved border along the top
and sides of the ramp at the level of the sidewalk. The concrete
curb ramp does not provide a detectable warning surface which
includes truncated domes.

Alternative *
Rec:
(Where
Available)

Curb Ramp Outside of Flats BBQ

Full Rec Remove the asphalt built-up curb ramp and install a compliant Citation CBC 1127B; ADAAG 4.7
curb-cut ramp that provides a slope no greater than 8.33% and
complies with CBC 1127B; ADAAG 4.7. Install a detectable
warning surface which extends the full length and width of the Minimum Quantity 1
concrete curb ramp and its side flares with truncated domes that Maximum Quantity: 1
contrast visually by either light on dark or dark on light which is
an integral part of the concrete curb ramp. The truncated Unit: Each
domes may be cast in place or stamped or of a prefabricated Minimum Estimated Cost: 1400
surface treatment (see CBC 1127B.5.8).
Maximum Estimated Cost: 1400
Record Number 129
Priority:

Curb Ramps
Finding: The slope of each side of the concrete sidewalk curb ramp is
greater than 8.33%. The concrete curb ramp does not provide a
detectable warning surface which includes truncated domes.

Alternative *
Rec:
(Where
Available)

Curb Ramp Outside of the Winners Gaming and Sports


Emporium

Full Rec Replace the curb ramp with a compliant curb ramp at least 48 Citation CBC 1127B.5.3; ADAAG 4.7.2 & 4.29
inches in width that provides a slope no greater than 8.33%.
Install a detectable warning surface which extends the full length
and width of the concrete curb ramp and its side flares with Minimum Quantity 1
truncated domes that contrast visually by either light on dark or Maximum Quantity: 1
dark on light which is an integral part of the concrete curb ramp.
The truncated domes may be cast in place or stamped or of a Unit: Each
prefabricated surface treatment (see CBC 1127B.5.8). Minimum Estimated Cost: 1033
Maximum Estimated Cost: 1033
Record Number 134
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 14 of 542


Facility Name: San Joaquin Fairgrounds
Curb Ramps
Finding: The slope of the curb ramp is greater than 8.33%. The slope of
the side flares is greater than 10%. The curb ramp does not
provide a grooved border along the top and sides of the ramp at
the level of the sidewalk. The concrete curb ramp does not
provide a detectable warning surface which includes truncated
domes.

Alternative *
Rec:
(Where
Available)

Curb Ramp to the Women's Showers

Full Rec Replace the curb ramp with a compliant curb ramp at least 48 Citation CBC 1127B.5.3; ADAAG 4.7.2 & 4.29
inches in width that provides a slope no greater than 8.33%.
Install a detectable warning surface which extends the full length
and width of the concrete curb ramp and its side flares with Minimum Quantity 1
truncated domes that contrast visually by either light on dark or Maximum Quantity: 1
dark on light which is an integral part of the concrete curb ramp.
The truncated domes may be cast in place or stamped or of a Unit: Each
prefabricated surface treatment (see CBC 1127B.5.8). Minimum Estimated Cost: 1033
Maximum Estimated Cost: 1033
Record Number 133
Priority:

Curb Ramps
Finding: The built-up curb ramps provided at the accessible parking
spaces outside of the Winners Gaming and Sports Emporium
project into an access aisle and interfere with individuals
entering or exiting parked or standing vehicles. The slope of the
side flares is greater than 10%. The concrete curb ramp does
not provide a detectable warning surface which includes
truncated domes.

Alternative *
Rec:
(Where
Available)

Curb Ramps at the Accessible Parking Spaces

Full Rec Remove each built-up curb ramp and install a compliant curb- Citation CBC 1127B; ADAAG 4.7
cut ramp that provides a slope no greater than 8.33% and
complies with CBC 1127B; ADAAG 4.7. Install a detectable
warning surface which extends the full length and width of the Minimum Quantity 1
concrete curb ramp and its side flares with truncated domes that Maximum Quantity: 7
contrast visually by either light on dark or dark on light which is
an integral part of the concrete curb ramp. The truncated Unit: Each
domes may be cast in place or stamped or of a prefabricated Minimum Estimated Cost: 1400
surface treatment (see CBC 1127B.5.8).
Maximum Estimated Cost: 9800
Record Number 132
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 15 of 542


Facility Name: San Joaquin Fairgrounds
Path of Travel
Finding: There is no accessible route from the public right of way off of B
Street to the accessible entrance of the facility. The accessible
route crosses vehicular traffic.

Alternative Post directional signage.


Rec:
(Where
Available)

Accessible Route from the Public Right of Way

Full Rec Provide at least one accessible route from the public right of Citation CBC 1114B.1.2; CBC 1117B.5.7; CBC 1127B.3;
way to the accessible entrance of the facility. Make certain to ADAAG 4.1.2(7); ADAAG 4.3.2; ADAAG 4.14.1
post signage indicating the direction to accessible building
entrances at every major junction along the accessible route. Minimum Quantity 1
Signs shall include the International Symbol of Accessibility. Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 107
Maximum Estimated Cost: 0
Record Number 202
Priority:

Path of Travel
Finding: There is no crosswalk provided on the path of travel from the
public right of way off of B Street to Flats BBQ. The required
accessible route crosses a vehicular way.

Alternative *
Rec:
(Where
Available)

Accessible Route from the Public Right of Way

Full Rec Stripe a crosswalk not less than 48 inches wide on the path of Citation ADAAG 4.7.9 ADAAG 4.2.9
travel to the accessible entrance of the facility. Provide a level
surface that does not exceed a slope greater than 5%. Cross
slopes shall not exceed 2%. Detectable warnings should be Minimum Quantity 1
placed at the entrance and exit of the crosswalk. Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 100
Maximum Estimated Cost: 100
Record Number 203
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 16 of 542


Facility Name: San Joaquin Fairgrounds
Path of Travel
Finding: There is no accessible route from the public right of way off of
South 8th Street to the accessible entrance of the facility. The
accessible route crosses vehicular traffic.

Alternative Post directional signage.


Rec:
(Where
Available)

Accessible Route from the Public Right of Way

Full Rec Provide at least one accessible route from the public right of Citation CBC 1114B.1.2; CBC 1117B.5.7; CBC 1127B.3;
way to the accessible entrance of the facility. Make certain to ADAAG 4.1.2(7); ADAAG 4.3.2; ADAAG 4.14.1
post signage indicating the direction to accessible building
entrances at every major junction along the accessible route. Minimum Quantity 1
Signs shall include the International Symbol of Accessibility. Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 107
Maximum Estimated Cost: 0
Record Number 221
Priority:

Path of Travel
Finding: There is no crosswalk provided on the path of travel from the
public right of way off of South 8th Street to the facility. The
required accessible route crosses a vehicular way.

Alternative *
Rec:
(Where
Available)

Accessible Route from the Public Right of Way

Full Rec Stripe a crosswalk not less than 48 inches wide on the path of Citation ADAAG 4.7.9 ADAAG 4.2.9
travel to the accessible entrance of the facility. Provide a level
surface that does not exceed a slope greater than 5%. Cross
slopes shall not exceed 2%. Detectable warnings should be Minimum Quantity 1
placed at the entrance and exit of the crosswalk. Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 100
Maximum Estimated Cost: 100
Record Number 222
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 17 of 542


Facility Name: San Joaquin Fairgrounds
Path of Travel
Finding: There are only stairs to the primary functions provided on the
stage in Building 2, preventing access to individuals with
mobility impairments.

Alternative *
Rec:
(Where
Available)

Building 2

Full Rec Install a vertical platform lift to provide a direct path between the Citation CBC 1114B.1.2; ADAAG 4.3.2
stage and level seating area in Building 2, allowing individuals
with mobility impairments to participate in programs, services
and activities provided by the facility on the stage. The ADA Minimum Quantity 1
mandates accessibility to programs, services and activities Maximum Quantity: 1
which serve the public.
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 8210
Record Number 189
Priority:

Path of Travel
Finding: The width of the gate next to the reception counter in Building 7
is less than 32 inches making the area nonaccessible to
individuals with mobility impairments.

Alternative *
Rec:
(Where
Available)

Building 7

Full Rec Modify or replace the gate, to provide at least 32 inches in width Citation CBC 1133B.1.1.1.4; CBC 1133B.1.1.1.1;
(see CBC 1133B.1.1.1.4; ADAAG 4.13.3). Make certain the ADAAG 4.13.3
gate provides level and clear landings on each side of the gate
and that each landing provides the minimum maneuvering Minimum Quantity 1
clearances required. The gate shall provide accessible Maximum Quantity: 1
hardware.
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 137
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 18 of 542


Facility Name: San Joaquin Fairgrounds
Path of Travel
Finding: The mat does not adhere to the underlying floor surface and
creates a hazardous path of travel.

Alternative *
Rec:
(Where
Available)

Building 7 Main Entrance

Full Rec Securely fasten the mats or replace with a mat that grips to the Citation CBC 1124B.3; ADAAG 4.5.3
underlying floor surface to provide a firm, stable, continuous and
relatively smooth path of travel surface (see CBC 1124B.3 and
ADAAG 4.5.3). Mats along the primary path of travel shall Minimum Quantity 1
provide beveled edges on all sides to prevent roll over. Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 659
Maximum Estimated Cost: 659
Record Number 136
Priority:

Path of Travel
Finding: There is grating outside of Building 6 with elongated openings
greater than 1/2 inch running the along the direction of travel.

Alternative *
Rec:
(Where
Available)

Drainage Grate

Full Rec Replace the grating with a grating that provides openings equal Citation CBC 1133B.7.2; ADAAG 4.5.4
to or less than 1/2 inch wide. If the grating has elongated
openings, the grating shall be set where the elongated openings
are perpendicular to the dominant direction of travel (see CBC Minimum Quantity 1
1133B.7.2 and ADAAG 4.5.4). Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 588
Maximum Estimated Cost: 588
Record Number 148
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 19 of 542


Facility Name: San Joaquin Fairgrounds
Path of Travel
Finding: Lockers are a service provided for public use in the exercise
room at the Stable Office. The lockers have hardware which
requires tight grasping, pinching, or twisting of the wrist and are
not accessible.

Alternative *
Rec:
(Where
Available)

Lockers

Full Rec When an individual with a disability has need for the locker Citation CBC 1105.4.3; ADAAG 4.27.4
service, modify a locker as needed or provide equivalent
facilitation upon request.
Minimum Quantity 1
Maximum Quantity: 1
Unit: None Selected
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 159
Priority:

Path of Travel
Finding: The mat at the south entrance to the Main Building does not
adhere to the underlying floor surface and creates a hazardous
path of travel.

Alternative *
Rec:
(Where
Available)

Main Building (South Entrance)

Full Rec Securely fasten the mats or replace with a mat that grips to the Citation CBC 1124B.3; ADAAG 4.5.3
underlying floor surface to provide a firm, stable, continuous and
relatively smooth path of travel surface (see CBC 1124B.3 and
ADAAG 4.5.3). Mats along the primary path of travel shall Minimum Quantity 1
provide beveled edges on all sides to prevent roll over. Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 659
Maximum Estimated Cost: 659
Record Number 166
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 20 of 542


Facility Name: San Joaquin Fairgrounds
Path of Travel
Finding: There are open tree wells along the path of travel in Building 6
with a change in elevation greater than 1/2 inch, creating a
tripping hazard.

Alternative
Rec:
(Where
Available)

Open Tree Wells

Full Rec Install edge protection on each side of the open tree well Citation ADAAG 4.3.8; CBC 1133B.7.1
consisting of 3-inch high guide curb above the surface of the
path of travel (see CBC 1133B.7.1 and ADAAG 4.3.8).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 70
Maximum Estimated Cost: 70
Record Number 149
Priority:

Path of Travel
Finding: There are open tree wells along the path of travel next to L-4
and L-5 with a change in elevation greater than 1/2 inch,
creating a tripping hazard.

Alternative
Rec:
(Where
Available)

Open Tree Wells

Full Rec Install edge protection on each side of the open tree well Citation ADAAG 4.3.8; CBC 1133B.7.1
consisting of 3-inch high guide curb above the surface of the
path of travel (see CBC 1133B.7.1 and ADAAG 4.3.8).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 70
Maximum Estimated Cost: 70
Record Number 152
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 21 of 542


Facility Name: San Joaquin Fairgrounds
Path of Travel
Finding: There are open tree wells along the path of travel south of L-5
with a change in elevation greater than 1/2 inch, creating a
tripping hazard.

Alternative
Rec:
(Where
Available)

Open Tree Wells

Full Rec Install edge protection on each side of the open tree well Citation ADAAG 4.3.8; CBC 1133B.7.1
consisting of 3-inch high guide curb above the surface of the
path of travel (see CBC 1133B.7.1 and ADAAG 4.3.8).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 70
Maximum Estimated Cost: 70
Record Number 213
Priority:

Path of Travel
Finding: There are slopes greater than 5% on the primary path of travel
between Buildings 5 and 6.

Alternative *
Rec:
(Where
Available)

Path of Travel Between Buildings 5 and 6

Full Rec Resurface the path of travel to provide a level surface that does Citation CBC 1133B.7.1.3; CBC 1133B.7.3; ADAAG 4.3.7
not exceed a slope greater than 5%. Cross slopes shall not
exceed 2%.
Minimum Quantity 1
Maximum Quantity: 1
Unit: 4' x 60'
Minimum Estimated Cost: 1440
Maximum Estimated Cost: 1440
Record Number 175
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 22 of 542


Facility Name: San Joaquin Fairgrounds
Path of Travel
Finding: There is a change in elevation greater than 1/2 inch on the
primary path of travel between L-4 and L-5.

Alternative *
Rec:
(Where
Available)

Path of Travel Between L-4 and L-5

Full Rec Bevel the area or resurface the area to provide a smooth and Citation CBC 1133B.7.4; ADAAG 4.3.8; ADAAG 4.5.2
level path of travel (see CBC 1133B.7.4 and ADAAG 4.3.8 and
ADAAG 4.5.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: 4' x 60'
Minimum Estimated Cost: 1440
Maximum Estimated Cost: 1440
Record Number 212
Priority:

Path of Travel
Finding: The walkway serves as a primary path of travel. The width of
the bridge is less than 48 inches in width. There are slopes
greater than 8.33% on the primary path of travel on the walkway.

Alternative *
Rec:
(Where
Available)

Path of Travel in Building 6

Full Rec Modify the exterior primary path of travel by extending the width Citation CBC 1133B.7.1; CBC 1133B.2.3; CBC 1118B.2;
of the walkway to at least 48 inches (see CBC 1118B.2 and ADAAG 4.1.3(16); ADAAG 4.3.3; ADAAG 4.30
ADAAG 4.3.3). Since the accessible route is less than 60
inches in width, provide passing spaces at least 60 inches by 60 Minimum Quantity 1
inches at reasonable intervals every 200 feet. Provide a level Maximum Quantity: 1
surface that does not exceed a slope greater than 5%. Cross
slopes shall not exceed 2%. Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 197
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 23 of 542


Facility Name: San Joaquin Fairgrounds
Path of Travel
Finding: The width of the interior path of travel behind the counter in L-1
is less than 36 inches.

Alternative *
Rec:
(Where
Available)

Path of Travel in L-1

Full Rec Modify the interior path of travel to provide at least 36 inches in Citation CBC 1118B.1; CBC 1118B.3; ADAAG 4.3.3
width. If the interior path of travel includes 180-degree turn
around an object, the clear width shall be at least 42 inches (see
CBC 1118B.1, CBC 1118B.3 and ADAAG 4.3.3). Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 141
Priority:

Path of Travel
Finding: The surface of the primary accessible path of travel is rough
and uneven, providing a hazardous surface for individuals with
mobility impairments and the general public.

Alternative *
Rec:
(Where
Available)

Path of Travel in L-1

Full Rec Resurface the path of travel to provide a smooth, firm, stable Citation CBC 1124B.1; ADAAG 4.3.6; ADAAG 4.5
and slip-resistant surface (see CBC 1124B.1, ADAAG 4.3.6 and
ADAAG 4.5).
Minimum Quantity 1
Maximum Quantity: 1
Unit: 4' x 60'
Minimum Estimated Cost: 1440
Maximum Estimated Cost: 1440
Record Number 200
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 24 of 542


Facility Name: San Joaquin Fairgrounds
Path of Travel
Finding: The surface of the primary accessible path of travel is rough
and uneven, providing a hazardous surface for individuals with
mobility impairments and the general public. There are cross
slopes greater than 2% on the primary path of travel.

Alternative *
Rec:
(Where
Available)

Path of Travel in L-4

Full Rec Resurface the path of travel to provide a smooth, firm, stable Citation CBC 1124B.1; ADAAG 4.3.6; ADAAG 4.5
and slip-resistant surface (see CBC 1124B.1, ADAAG 4.3.6 and
ADAAG 4.5). Provide a level surface that does not exceed a
slope greater than 5%. Cross slopes shall not exceed 2%. Minimum Quantity 1
Maximum Quantity: 1
Unit: 4' x 60'
Minimum Estimated Cost: 1440
Maximum Estimated Cost: 1440
Record Number 211
Priority:

Path of Travel
Finding: There is a change in elevation greater than 1/2 inch on the
primary path of travel.

Alternative *
Rec:
(Where
Available)

Path of Travel in the FFA Office

Full Rec Bevel the area or resurface the area to provide a smooth and Citation CBC 1133B.7.4; ADAAG 4.3.8; ADAAG 4.5.2
level path of travel (see CBC 1133B.7.4 and ADAAG 4.3.8 and
ADAAG 4.5.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: 4' x 60'
Minimum Estimated Cost: 1440
Maximum Estimated Cost: 1440
Record Number 172
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 25 of 542


Facility Name: San Joaquin Fairgrounds
Path of Travel
Finding: There are slopes greater than 5% on the primary path of travel
at the west end of the Linden Lions Building.

Alternative *
Rec:
(Where
Available)

Path of Travel in the West End of the Linden Lions Building

Full Rec Resurface the path of travel to provide a level surface that does Citation CBC 1133B.7.1.3; CBC 1133B.7.3; ADAAG 4.3.7
not exceed a slope greater than 5%. Cross slopes shall not
exceed 2%.
Minimum Quantity 1
Maximum Quantity: 1
Unit: 4' x 60'
Minimum Estimated Cost: 1440
Maximum Estimated Cost: 1440
Record Number 153
Priority:

Path of Travel
Finding: The typical paths of travel throughout Building 6 is gravel,
preventing access to individuals with mobility impairments. The
width of typical walkways is less than 48 inches in width.

Alternative *
Rec:
(Where
Available)

Path of Travel Throughout Building 6

Full Rec Install an accessible route to where programs, services and Citation CBC 1114B.1.2; ADAAG 4.3.6
activities are provided (see CBC 1114B.1.2 and ADAAG 4.3.2).
The minimum width of the path of travel shall be 48 inches with
a firm, stable and slip-resistant surface. No protruding objects Minimum Quantity 1
are permitted on the accessible path of travel and slopes shall Maximum Quantity: 1
not exceed 5% in the direction of travel.
Unit: 4' x 60'
Minimum Estimated Cost: 1440
Maximum Estimated Cost: 1440
Record Number 198
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 26 of 542


Facility Name: San Joaquin Fairgrounds
Path of Travel
Finding: The surface of the primary accessible path of travel is rough
and uneven, providing a hazardous surface for individuals with
mobility impairments and the general public.

Alternative *
Rec:
(Where
Available)

Path of Travel Throughout L-2

Full Rec Resurface the path of travel to provide a smooth, firm, stable Citation CBC 1124B.1; ADAAG 4.3.6; ADAAG 4.5
and slip-resistant surface (see CBC 1124B.1, ADAAG 4.3.6 and
ADAAG 4.5).
Minimum Quantity 1
Maximum Quantity: 1
Unit: 4' x 60'
Minimum Estimated Cost: 1440
Maximum Estimated Cost: 1440
Record Number 169
Priority:

Path of Travel
Finding: The surface of the primary accessible path of travel is rough
and uneven, providing a hazardous surface for individuals with
mobility impairments and the general public.

Alternative *
Rec:
(Where
Available)

Path of Travel Throughout L-3

Full Rec Resurface the path of travel to provide a smooth, firm, stable Citation CBC 1124B.1; ADAAG 4.3.6; ADAAG 4.5
and slip-resistant surface (see CBC 1124B.1, ADAAG 4.3.6 and
ADAAG 4.5).
Minimum Quantity 1
Maximum Quantity: 1
Unit: 4' x 60'
Minimum Estimated Cost: 1440
Maximum Estimated Cost: 1440
Record Number 170
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 27 of 542


Facility Name: San Joaquin Fairgrounds
Path of Travel
Finding: The path of travel from the parking lot to Building 4 is gravel,
preventing access to individuals with mobility impairments.

Alternative *
Rec:
(Where
Available)

Path of Travel to Building 4

Full Rec Install an accessible route to where programs, services and Citation CBC 1114B.1.2; ADAAG 4.3.6
activities are provided (see CBC 1114B.1.2 and ADAAG 4.3.2).
The minimum width of the path of travel shall be 48 inches with
a firm, stable and slip-resistant surface. No protruding objects Minimum Quantity 1
are permitted on the accessible path of travel and slopes shall Maximum Quantity: 1
not exceed 5% in the direction of travel.
Unit: 4' x 60'
Minimum Estimated Cost: 1440
Maximum Estimated Cost: 1440
Record Number 151
Priority:

Path of Travel
Finding: The surface of the primary accessible path of travel from
Building 6 to Building 5 is rough and uneven, providing a
hazardous surface for individuals with mobility impairments and
the general public.

Alternative *
Rec:
(Where
Available)

Path of Travel to Building 5

Full Rec Resurface the path of travel to provide a smooth, firm, stable Citation CBC 1124B.1; ADAAG 4.3.6; ADAAG 4.5
and slip-resistant surface (see CBC 1124B.1, ADAAG 4.3.6 and
ADAAG 4.5).
Minimum Quantity 1
Maximum Quantity: 1
Unit: 4' x 60'
Minimum Estimated Cost: 1440
Maximum Estimated Cost: 1440
Record Number 196
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 28 of 542


Facility Name: San Joaquin Fairgrounds
Path of Travel
Finding: The path of travel to the north entrance of Building 5 is grass,
preventing access to individuals with mobility impairments.

Alternative *
Rec:
(Where
Available)

Path of Travel to Building 5 (North Entrance)

Full Rec Install an accessible route to where programs, services and Citation CBC 1114B.1.2; ADAAG 4.3.6
activities are provided (see CBC 1114B.1.2 and ADAAG 4.3.2).
The minimum width of the path of travel shall be 48 inches with
a firm, stable and slip-resistant surface. No protruding objects Minimum Quantity 1
are permitted on the accessible path of travel and slopes shall Maximum Quantity: 1
not exceed 5% in the direction of travel.
Unit: 4' x 60'
Minimum Estimated Cost: 1440
Maximum Estimated Cost: 1440
Record Number 215
Priority:

Path of Travel
Finding: The path of travel to the south entrance to Building 6 is grass,
preventing access to individuals with mobility impairments.

Alternative *
Rec:
(Where
Available)

Path of Travel to Building 6 (South Entrance)

Full Rec Install an accessible route to where programs, services and Citation CBC 1114B.1.2; ADAAG 4.3.6
activities are provided (see CBC 1114B.1.2 and ADAAG 4.3.2).
The minimum width of the path of travel shall be 48 inches with
a firm, stable and slip-resistant surface. No protruding objects Minimum Quantity 1
are permitted on the accessible path of travel and slopes shall Maximum Quantity: 1
not exceed 5% in the direction of travel.
Unit: 4' x 60'
Minimum Estimated Cost: 1440
Maximum Estimated Cost: 1440
Record Number 214
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 29 of 542


Facility Name: San Joaquin Fairgrounds
Path of Travel
Finding: There is a step on the primary path of travel to Building 8,
preventing access to individuals with mobility impairments.

Alternative *
Rec:
(Where
Available)

Path of Travel to Building 8

Full Rec Since programs, services and activities to staff and the public Citation CBC 1114B.1.2; CBC 1133B.7.4; ADAAG 4.3.8
(volunteers, etc.) are provided in this location, those programs,
services and activities are required to be made accessible. It is
recommended that a ramp be installed or other means of Minimum Quantity 1
vertical access. Maximum Quantity: 1
Unit: 60 Linear Feet
Minimum Estimated Cost: 9515
Maximum Estimated Cost: 9515
Record Number 135
Priority:

Path of Travel
Finding: The path of travel is to L-6 grass, preventing access to
individuals with mobility impairments.

Alternative *
Rec:
(Where
Available)

Path of Travel to L-6

Full Rec Install an accessible route to where programs, services and Citation CBC 1114B.1.2; ADAAG 4.3.6
activities are provided (see CBC 1114B.1.2 and ADAAG 4.3.2).
The minimum width of the path of travel shall be 48 inches with
a firm, stable and slip-resistant surface. No protruding objects Minimum Quantity 1
are permitted on the accessible path of travel and slopes shall Maximum Quantity: 1
not exceed 5% in the direction of travel.
Unit: 4' x 60'
Minimum Estimated Cost: 1440
Maximum Estimated Cost: 1440
Record Number 143
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 30 of 542


Facility Name: San Joaquin Fairgrounds
Path of Travel
Finding: The path of travel to the annex next to the Jockey's Quarters is
dirt, preventing access to individuals with mobility impairments.

Alternative *
Rec:
(Where
Available)

Path of Travel to the Annex Next to the Jockey's Quarters

Full Rec Install an accessible route to where programs, services and Citation CBC 1114B.1.2; ADAAG 4.3.6
activities are provided (see CBC 1114B.1.2 and ADAAG 4.3.2).
The minimum width of the path of travel shall be 48 inches with
a firm, stable and slip-resistant surface. No protruding objects Minimum Quantity 1
are permitted on the accessible path of travel and slopes shall Maximum Quantity: 1
not exceed 5% in the direction of travel.
Unit: 4' x 60'
Minimum Estimated Cost: 1440
Maximum Estimated Cost: 1440
Record Number 259
Priority:

Path of Travel
Finding: There are only stairs to the primary functions provided,
preventing access to individuals with mobility impairments.

Alternative *
Rec:
(Where
Available)

Path of Travel to the Annex Next to the Jockey's Quarters

Full Rec Since programs, services and activities to staff and the public Citation CBC 1133B.5; ADAAG 4.3.2
(volunteers, etc.) are provided in this location, those programs,
services and activities are required to be made accessible. It is
recommended that a ramp be installed or other means of Minimum Quantity 1
vertical access. Maximum Quantity: 1
Unit: 60 Linear Feet
Minimum Estimated Cost: 9515
Maximum Estimated Cost: 9515
Record Number 260
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 31 of 542


Facility Name: San Joaquin Fairgrounds
Path of Travel
Finding: There are slopes greater than 5% on the primary path of travel
to the bleachers at the Delta Speedway.

Alternative *
Rec:
(Where
Available)

Path of Travel to the Bleachers at the Delta Speedway

Full Rec Resurface the path of travel to provide a level surface that does Citation CBC 1133B.7.1.3; CBC 1133B.7.3; ADAAG 4.3.7
not exceed a slope greater than 5%. Cross slopes shall not
exceed 2%.
Minimum Quantity 1
Maximum Quantity: 1
Unit: 4' x 60'
Minimum Estimated Cost: 1440
Maximum Estimated Cost: 1440
Record Number 178
Priority:

Path of Travel
Finding: There are slopes greater than 5% on the primary path of travel
between the men's and women's restroom at the Grandstand.

Alternative *
Rec:
(Where
Available)

Path of Travel to the Bleachers at the Grandstand

Full Rec Resurface the path of travel to provide a level surface that does Citation CBC 1133B.7.1.3; CBC 1133B.7.3; ADAAG 4.3.7
not exceed a slope greater than 5%. Cross slopes shall not
exceed 2%.
Minimum Quantity 1
Maximum Quantity: 1
Unit: 4' x 60'
Minimum Estimated Cost: 1440
Maximum Estimated Cost: 1440
Record Number 145
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 32 of 542


Facility Name: San Joaquin Fairgrounds
Path of Travel
Finding: There is a change in elevation greater than 1/2 inch on the
primary path of travel.

Alternative *
Rec:
(Where
Available)

Path of Travel to the Building 5 Main Entrance

Full Rec Bevel the area or resurface the area to provide a smooth and Citation CBC 1133B.7.4; ADAAG 4.3.8; ADAAG 4.5.2
level path of travel (see CBC 1133B.7.4 and ADAAG 4.3.8 and
ADAAG 4.5.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: 4' x 60'
Minimum Estimated Cost: 1440
Maximum Estimated Cost: 1440
Record Number 150
Priority:

Path of Travel
Finding: There are slopes greater than 8.33% on the primary path of
travel on the walkway to the concession stand at the south east
end of the Grandstand.

Alternative *
Rec:
(Where
Available)

Path of Travel to the Concession Stand

Full Rec Resurface the path of travel to provide a level surface that does Citation CBC 1133B.7.1.3; CBC 1133B.7.3; ADAAG 4.3.7
not exceed a slope greater than 5%. Cross slopes shall not
exceed 2%. Otherwise, install a ramp that does not exceed a
slope greater than 8.33% and complies with CBC 1133B.5 and Minimum Quantity 1
ADAAG 4.8. Maximum Quantity: 1
Unit: 4' x 60'
Minimum Estimated Cost: 1440
Maximum Estimated Cost: 1440
Record Number 144
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 33 of 542


Facility Name: San Joaquin Fairgrounds
Path of Travel
Finding: There are slopes greater than 5% on the primary path of travel
to the concession stand at the Delta Speedway.

Alternative *
Rec:
(Where
Available)

Path of Travel to the Concession Stand at the Delta


Speedway

Full Rec Resurface the path of travel to provide a level surface that does Citation CBC 1133B.7.1.3; CBC 1133B.7.3; ADAAG 4.3.7
not exceed a slope greater than 5%. Cross slopes shall not
exceed 2%.
Minimum Quantity 1
Maximum Quantity: 1
Unit: 4' x 60'
Minimum Estimated Cost: 1440
Maximum Estimated Cost: 1440
Record Number 177
Priority:

Path of Travel
Finding: There are slopes greater than 5% on the primary path of travel
from the restrooms to the concession stand at the Delta
Speedway.

Alternative *
Rec:
(Where
Available)

Path of Travel to the Concession Stand at the Delta


Speedway

Full Rec Resurface the path of travel to provide a level surface that does Citation CBC 1133B.7.1.3; CBC 1133B.7.3; ADAAG 4.3.7
not exceed a slope greater than 5%. Cross slopes shall not
exceed 2%.
Minimum Quantity 1
Maximum Quantity: 1
Unit: 4' x 60'
Minimum Estimated Cost: 1440
Maximum Estimated Cost: 1440
Record Number 179
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 34 of 542


Facility Name: San Joaquin Fairgrounds
Path of Travel
Finding: There are slopes greater than 8.33% on the primary path of
travel on the walkway from Charter Way to the Delta Speedway.

Alternative *
Rec:
(Where
Available)

Path of Travel to the Delta Speedway

Full Rec Resurface the path of travel to provide a level surface that does Citation CBC 1133B.7.1.3; CBC 1133B.7.3; ADAAG 4.3.7
not exceed a slope greater than 5%. Cross slopes shall not
exceed 2%. Otherwise, install a ramp that does not exceed a
slope greater than 8.33% and complies with CBC 1133B.5 and Minimum Quantity 1
ADAAG 4.8. Maximum Quantity: 1
Unit: 4' x 60'
Minimum Estimated Cost: 1440
Maximum Estimated Cost: 1440
Record Number 201
Priority:

Path of Travel
Finding: There is a step on the primary path of travel to the First Aid
Room in the Maintenance Building, preventing access to
individuals with mobility impairments.

Alternative *
Rec:
(Where
Available)

Path of Travel to the First Aid Room

Full Rec Since programs, services and activities to staff and the public Citation CBC 1114B.1.2; CBC 1133B.7.4; ADAAG 4.3.8
(volunteers, etc.) are provided in this location, those programs,
services and activities are required to be made accessible. It is
recommended that a ramp be installed or other means of Minimum Quantity 1
vertical access. Maximum Quantity: 1
Unit: 60 Linear Feet
Minimum Estimated Cost: 9515
Maximum Estimated Cost: 9515
Record Number 193
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 35 of 542


Facility Name: San Joaquin Fairgrounds
Path of Travel
Finding: The path of travel to Horse Barns A thru U, excluding Horse
Barn S, is dirt, preventing access to individuals with mobility
impairments.

Alternative *
Rec:
(Where
Available)

Path of Travel to the Horse Barns

Full Rec Install an accessible route to where programs, services and Citation CBC 1114B.1.2; ADAAG 4.3.6
activities are provided (see CBC 1114B.1.2 and ADAAG 4.3.2).
The minimum width of the path of travel shall be 48 inches with
a firm, stable and slip-resistant surface. No protruding objects Minimum Quantity 1
are permitted on the accessible path of travel and slopes shall Maximum Quantity: 1
not exceed 5% in the direction of travel.
Unit: 4' x 60'
Minimum Estimated Cost: 1440
Maximum Estimated Cost: 1440
Record Number 176
Priority:

Path of Travel
Finding: The path of travel from the Stable Office to the Horse Barns is a
combination of dirt, gravel and asphalt, preventing access to
individuals with mobility impairments.

Alternative *
Rec:
(Where
Available)

Path of Travel to the Horse Barns

Full Rec Install an accessible route to where programs, services and Citation CBC 1114B.1.2; ADAAG 4.3.6
activities are provided (see CBC 1114B.1.2 and ADAAG 4.3.2).
The minimum width of the path of travel shall be 48 inches with
a firm, stable and slip-resistant surface. No protruding objects Minimum Quantity 1
are permitted on the accessible path of travel and slopes shall Maximum Quantity: 1
not exceed 5% in the direction of travel.
Unit: 4' x 60'
Minimum Estimated Cost: 1440
Maximum Estimated Cost: 1440
Record Number 204
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 36 of 542


Facility Name: San Joaquin Fairgrounds
Path of Travel
Finding: The path of travel to the north entrance of the Jockey's Quarters
is dirt, preventing access to individuals with mobility
impairments.

Alternative *
Rec:
(Where
Available)

Path of Travel to the Jockey's Quarters (North Entrance)

Full Rec Install an accessible route to where programs, services and Citation CBC 1114B.1.2; ADAAG 4.3.6
activities are provided (see CBC 1114B.1.2 and ADAAG 4.3.2).
The minimum width of the path of travel shall be 48 inches with
a firm, stable and slip-resistant surface. No protruding objects Minimum Quantity 1
are permitted on the accessible path of travel and slopes shall Maximum Quantity: 1
not exceed 5% in the direction of travel.
Unit: 4' x 60'
Minimum Estimated Cost: 1440
Maximum Estimated Cost: 1440
Record Number 205
Priority:

Path of Travel
Finding: The path of travel to the Linden Lions Building is grass,
preventing access to individuals with mobility impairments.

Alternative *
Rec:
(Where
Available)

Path of Travel to the Linden Lions Building

Full Rec Install an accessible route to where programs, services and Citation CBC 1114B.1.2; ADAAG 4.3.6
activities are provided (see CBC 1114B.1.2 and ADAAG 4.3.2).
The minimum width of the path of travel shall be 48 inches with
a firm, stable and slip-resistant surface. No protruding objects Minimum Quantity 1
are permitted on the accessible path of travel and slopes shall Maximum Quantity: 1
not exceed 5% in the direction of travel.
Unit: 4' x 60'
Minimum Estimated Cost: 1440
Maximum Estimated Cost: 1440
Record Number 154
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 37 of 542


Facility Name: San Joaquin Fairgrounds
Path of Travel
Finding: There are slopes greater than 5% on the primary path of travel
to the men's restroom next to Horse Barn N.

Alternative *
Rec:
(Where
Available)

Path of Travel to the Men's Restroom Next to Horse Barn N

Full Rec Resurface the path of travel to provide a level surface that does Citation CBC 1133B.7.1.3; CBC 1133B.7.3; ADAAG 4.3.7
not exceed a slope greater than 5%. Cross slopes shall not
exceed 2%.
Minimum Quantity 1
Maximum Quantity: 1
Unit: 4' x 60'
Minimum Estimated Cost: 1440
Maximum Estimated Cost: 1440
Record Number 130
Priority:

Path of Travel
Finding: There are slopes greater than 5% on the primary path of travel
to the men's restroom next to Horse Barn Q.

Alternative *
Rec:
(Where
Available)

Path of Travel to the Men's Restroom Next to Horse Barn Q

Full Rec Resurface the path of travel to provide a level surface that does Citation CBC 1133B.7.1.3; CBC 1133B.7.3; ADAAG 4.3.7
not exceed a slope greater than 5%. Cross slopes shall not
exceed 2%.
Minimum Quantity 1
Maximum Quantity: 1
Unit: 4' x 60'
Minimum Estimated Cost: 1440
Maximum Estimated Cost: 1440
Record Number 305
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 38 of 542


Facility Name: San Joaquin Fairgrounds
Path of Travel
Finding: There are slopes greater than 5%, due to an asphalt build-up,
on the primary path of travel to the men's showers next to the
Livestock Office.

Alternative *
Rec:
(Where
Available)

Path of Travel to the Men's Showers Next to the Livestock


Office

Full Rec Resurface the path of travel to provide a level surface that does Citation CBC 1133B.7.1.3; CBC 1133B.7.3; ADAAG 4.3.7
not exceed a slope greater than 5%. Cross slopes shall not
exceed 2%.
Minimum Quantity 1
Maximum Quantity: 1
Unit: 4' x 60'
Minimum Estimated Cost: 1440
Maximum Estimated Cost: 1440
Record Number 713
Priority:

Path of Travel
Finding: There is a step on the primary path of travel to the milk parlor,
preventing access to individuals with mobility impairments.

Alternative *
Rec:
(Where
Available)

Path of Travel to the Milk Parlor

Full Rec Since programs, services and activities to staff and the public Citation CBC 1114B.1.2; CBC 1133B.7.4; ADAAG 4.3.8
(volunteers, etc.) are provided in this location, those programs,
services and activities are required to be made accessible. It is
recommended that a ramp be installed or other means of Minimum Quantity 1
vertical access. Maximum Quantity: 1
Unit: 60 Linear Feet
Minimum Estimated Cost: 9515
Maximum Estimated Cost: 9515
Record Number 199
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 39 of 542


Facility Name: San Joaquin Fairgrounds
Path of Travel
Finding: There are slopes greater than 5% on the primary path of travel
to the press box at the Delta Speedway.

Alternative *
Rec:
(Where
Available)

Path of Travel to the Pressbox at the Delta Speedway

Full Rec Resurface the path of travel to provide a level surface that does Citation CBC 1133B.7.1.3; CBC 1133B.7.3; ADAAG 4.3.7
not exceed a slope greater than 5%. Cross slopes shall not
exceed 2%.
Minimum Quantity 1
Maximum Quantity: 1
Unit: 4' x 60'
Minimum Estimated Cost: 1440
Maximum Estimated Cost: 1440
Record Number 1178
Priority:

Path of Travel
Finding: There are slopes greater than 5% on the primary path of travel
to the second level of the Grandstands.

Alternative *
Rec:
(Where
Available)

Path of Travel to the Second Level of the Grandstands

Full Rec Resurface the path of travel to provide a level surface that does Citation CBC 1133B.7.1.3; CBC 1133B.7.3; ADAAG 4.3.7
not exceed a slope greater than 5%. Cross slopes shall not
exceed 2%.
Minimum Quantity 1
Maximum Quantity: 1
Unit: 4' x 60'
Minimum Estimated Cost: 1440
Maximum Estimated Cost: 1440
Record Number 147
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 40 of 542


Facility Name: San Joaquin Fairgrounds
Path of Travel
Finding: There are only stairs to the primary functions provided,
preventing access to individuals with mobility impairments.

Alternative *
Rec:
(Where
Available)

Path of Travel to the Stockton Motorplex Office

Full Rec Since programs, services and activities to staff and the public Citation CBC 1133B.5; ADAAG 4.3.2
(volunteers, etc.) are provided in this location, those programs,
services and activities are required to be made accessible. It is
recommended that a ramp be installed or other means of Minimum Quantity 1
vertical access. Maximum Quantity: 1
Unit: 60 Linear Feet
Minimum Estimated Cost: 9515
Maximum Estimated Cost: 9515
Record Number 164
Priority:

Path of Travel
Finding: There are slopes greater than 5% on the primary path of travel
to the women's restroom at the Grandstand.

Alternative *
Rec:
(Where
Available)

Path of Travel to the Women's Restroom at the Grandstand

Full Rec Resurface the path of travel to provide a level surface that does Citation CBC 1133B.7.1.3; CBC 1133B.7.3; ADAAG 4.3.7
not exceed a slope greater than 5%. Cross slopes shall not
exceed 2%.
Minimum Quantity 1
Maximum Quantity: 1
Unit: 4' x 60'
Minimum Estimated Cost: 1440
Maximum Estimated Cost: 1440
Record Number 167
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 41 of 542


Facility Name: San Joaquin Fairgrounds
Path of Travel
Finding: There are slopes greater than 5%, due to an asphalt build-up,
on the primary path of travel to the women's restroom at the
soccer field.

Alternative *
Rec:
(Where
Available)

Path of Travel to the Women's Restroom at the Soccer


Field

Full Rec Resurface the path of travel to provide a level surface that does Citation CBC 1133B.7.1.3; CBC 1133B.7.3; ADAAG 4.3.7
not exceed a slope greater than 5%. Cross slopes shall not
exceed 2%.
Minimum Quantity 1
Maximum Quantity: 1
Unit: 4' x 60'
Minimum Estimated Cost: 1440
Maximum Estimated Cost: 1440
Record Number 896
Priority:

Path of Travel
Finding: There are slopes greater than 5% on the primary path of travel
to the women's restroom next to horse barn 4.

Alternative *
Rec:
(Where
Available)

Path of Travel to the Women's Restroom Next to Horse


Barn 4

Full Rec Resurface the path of travel to provide a level surface that does Citation CBC 1133B.7.1.3; CBC 1133B.7.3; ADAAG 4.3.7
not exceed a slope greater than 5%. Cross slopes shall not
exceed 2%.
Minimum Quantity 1
Maximum Quantity: 1
Unit: 4' x 60'
Minimum Estimated Cost: 1440
Maximum Estimated Cost: 1440
Record Number 467
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 42 of 542


Facility Name: San Joaquin Fairgrounds
Path of Travel
Finding: There is no accessible route to the picnic tables in the outdoor
dining area east of Building 6.

Alternative *
Rec:
(Where
Available)

Picnic Tables East of Building 6

Full Rec Install a 48-inch wide path to the picnic tables in the outdoor Citation ADAAG 5.8; ADAAG A4.2.5; ADAAG A4.2.6
dining area that provides a smooth, stable, firm and slip
resistant surface. Provide a maneuvering space sufficient to
provide a 60-inch diameter turning radius adjacent to at least Minimum Quantity 1
one of the picnic tables in the outdoor dining area. Maximum Quantity: 1
Unit: 4' x 60'
Minimum Estimated Cost: 1440
Maximum Estimated Cost: 1440
Record Number 194
Priority:

Path of Travel
Finding: The knee space at the tables in the outdoor dining area is less
than 27 inches high.

Alternative *
Rec:
(Where
Available)

Picnic Tables East of Building 6

Full Rec Modify or replace one of the tables in the outdoor dining area to Citation CBC 1122B.3; ADAAG 4.32.2; ADAAG 4.32.5(2)
provide knee clearance of at least 27 inches in height, 30 inches
in width and 19 inches in depth (see CBC 1122B.3, ADAAG
4.32.2 and ADAAG Figure 45). The table top height shall not Minimum Quantity 1
exceed 34 inches above the finished floor. Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 174
Maximum Estimated Cost: 174
Record Number 195
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 43 of 542


Facility Name: San Joaquin Fairgrounds
Path of Travel
Finding: The leading edge of the wall-mounted storage compartments in
the Jockey's Quarters is more than 4 inches from the wall and
greater than 27 inches from the floor and protrudes into the
primary path of travel.

Alternative *
Rec:
(Where
Available)

Protruding Object

Full Rec Install side extensions, modify, relocate, or lower the storage Citation CBC 1121B.1; ADAAG 4.4
compartments so that the leading edge protrudes less than 4
inches from the wall, or are less than 27 inches from the floor
(see CBC 1121B.1 and ADAAG 4.4). Minimum Quantity 1
Maximum Quantity: 1
Unit: 128 Sq Ft
Minimum Estimated Cost: 640
Maximum Estimated Cost: 640
Record Number 157
Priority:

Path of Travel
Finding: The leading edge of the wall-mounted box outside of the
Livestock Office is more than 4 inches from the wall and greater
than 27 inches from the floor and protrudes into the primary
path of travel.

Alternative *
Rec:
(Where
Available)

Protruding Object

Full Rec Install side extensions, modify, relocate, or lower the box so that Citation CBC 1121B.1; ADAAG 4.4
the leading edge protrudes less than 4 inches from the wall, or
are less than 27 inches from the floor (see CBC 1121B.1 and
ADAAG 4.4). Minimum Quantity 1
Maximum Quantity: 1
Unit: 128 Sq Ft
Minimum Estimated Cost: 640
Maximum Estimated Cost: 640
Record Number 171
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 44 of 542


Facility Name: San Joaquin Fairgrounds
Path of Travel
Finding: The leading edge of the fire extinguisher at the north end of the
Grandstands, Building 6, at the north entrance to Building 3, the
east entrance to Building 5, in the Stable Office, the break room
in the Administration Building and in Building 4 is more than 4
inches from the wall and greater than 27 inches from the floor
and protrudes into the primary path of travel.

Alternative *
Rec:
(Where
Available)

Protruding Object

Full Rec Consult with the local fire marshal to determine the feasibility of Citation CBC 1121B.1; ADAAG 4.2.4.1; ADAAG 4.4
moving the fire extinguishers to new locations (such as in a
corner) to eliminate the protrusion into the primary path of
travel. Otherwise, install side extensions or wing walls on each Minimum Quantity 1
fire extinguisher throughout the facility so that the leading edges Maximum Quantity: 1
are less than 27 inches from the floor (see CBC 1121B.1 and
ADAAG 4.4). Unit: None Selected
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 173
Priority:

Path of Travel
Finding: The leading edge of the wall-mounted counter in the
Grandstands is more than 4 inches from the wall and greater
than 27 inches from the floor and protrudes into the primary
path of travel.

Alternative *
Rec:
(Where
Available)

Protruding Object

Full Rec Install side extensions, modify, relocate, or lower the counter so Citation CBC 1121B.1; ADAAG 4.4
that the leading edge protrudes less than 4 inches from the wall,
or are less than 27 inches from the floor (see CBC 1121B.1 and
ADAAG 4.4). Minimum Quantity 1
Maximum Quantity: 1
Unit: 128 Sq Ft
Minimum Estimated Cost: 640
Maximum Estimated Cost: 640
Record Number 1177
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 45 of 542


Facility Name: San Joaquin Fairgrounds
Path of Travel
Finding: The beams throughout the Grandstand protrude into the primary
path of travel by providing a hazardous height range greater
than 27 inches and less than 80 inches from the floor.

Alternative *
Rec:
(Where
Available)

Protruding Objects

Full Rec Install side extensions or other permanent devices that extend Citation CBC 1121B.1; ADAAG 4.2.4.1; ADAAG 4.4
lower than 27 inches from the floor surface to prevent it from
protruding into the primary path of travel.
Minimum Quantity 1
Maximum Quantity: 1
Unit: 128 Sq Ft
Minimum Estimated Cost: 640
Maximum Estimated Cost: 640
Record Number 146
Priority:

Path of Travel
Finding: The leading edge of each display case in the Winners Gaming
and Sports Emporium is more than 4 inches from the wall and
greater than 27 inches from the floor and protrudes into the
primary path of travel.

Alternative *
Rec:
(Where
Available)

Protruding Objects

Full Rec Install side extensions or wing walls on each display case so Citation CBC 1121B.1; ADAAG 4.2.4.1; ADAAG 4.4
that its leading edge is less than 27 inches from the floor.

Minimum Quantity 1
Maximum Quantity: 4
Unit: 128 Sq Ft
Minimum Estimated Cost: 640
Maximum Estimated Cost: 2560
Record Number 165
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 46 of 542


Facility Name: San Joaquin Fairgrounds
Path of Travel
Finding: The leading edge of the electrical outlets in L-2 and L-3 is more
than 4 inches from the wall and less than 80 inches above the
floor and protrudes into the primary path of travel.

Alternative *
Rec:
(Where
Available)

Protruding Objects

Full Rec Modify or relocate the electrical outlets so that the leading edge Citation CBC 1121B.1; ADAAG 4.4
protrudes less than 4 inches from the wall and is at least 80
inches above the floor (see CBC 1121B.1 and ADAAG 4.4).
Minimum Quantity 1
Maximum Quantity: 1
Unit: 128 Sq Ft
Minimum Estimated Cost: 640
Maximum Estimated Cost: 640
Record Number 168
Priority:

Path of Travel
Finding: The leading edge of the display cases in Building 6 is more than
4 inches from the wall and greater than 27 inches from the floor
and protrudes into the primary path of travel.

Alternative *
Rec:
(Where
Available)

Protruding Objects

Full Rec Install side extensions or wing walls on the display case so that Citation CBC 1121B.1; ADAAG 4.2.4.1; ADAAG 4.4
its leading edge is less than 27 inches from the floor.

Minimum Quantity 1
Maximum Quantity: 1
Unit: 128 Sq Ft
Minimum Estimated Cost: 640
Maximum Estimated Cost: 640
Record Number 218
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 47 of 542


Facility Name: San Joaquin Fairgrounds
Path of Travel
Finding: The sink in Building 7 is in an enclosed cabinet, thereby
preventing an accessible forward approach. The height of the
counter surface is greater than 34 inches above the finished
floor.

Alternative *
Rec:
(Where
Available)

Sink in Building 7

Full Rec Sinks in rooms must provide clear floor space in front of the sink Citation ADAAG 4.19.3
for an accessible forward approach and shall provide at least 27
inches clear knee space and a minimum of nine inches clear toe
space (see ADAAG 4.19.2). If neither clear floor space and Minimum Quantity 1
knee and toe clearance can be provided, remove the sink Maximum Quantity: 1
cabinet and replace with an accessible wall-mounted sink unit.
Unit: Each
Minimum Estimated Cost: 420
Maximum Estimated Cost: 420
Record Number 138
Priority:

Path of Travel
Finding: The pipes under the sink in Building 7 do not provide protection
against contact.

Alternative *
Rec:
(Where
Available)

Sink in Building 7

Full Rec Insulate or otherwise configure pipes under the sink designated Citation ADAAG 4.19.4
to be accessible in the room to protect against contact (see
ADAAG 4.19.4). Make certain there are no sharp or abrasive
surfaces under the sink. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 39
Maximum Estimated Cost: 39
Record Number 139
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 48 of 542


Facility Name: San Joaquin Fairgrounds
Path of Travel
Finding: The faucet controls on the sink in Building 7 require tight
grasping, pinching, or twisting of the wrist and are not
accessible.

Alternative *
Rec:
(Where
Available)

Sink in Building 7

Full Rec Install faucet controls complying with ADAAG 4.19.5 on the sink Citation ADAAG 4.19.5
designated to be accessible in Building 7. Lever-operated, push-
type, touch-type or electronically controlled mechanisms are
acceptable elements (see ADAAG 4.19.5). If self-closing valves Minimum Quantity 1
are used the faucet shall remain open for at least 10 seconds. Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 392
Maximum Estimated Cost: 392
Record Number 140
Priority:

Path of Travel
Finding: The sink in Building 8 is in an enclosed cabinet, thereby
preventing an accessible forward approach. The height of the
counter surface is greater than 34 inches above the finished
floor.

Alternative *
Rec:
(Where
Available)

Sink in Building 8

Full Rec Sinks in rooms must provide clear floor space in front of the sink Citation ADAAG 4.19.3
for an accessible forward approach and shall provide at least 27
inches clear knee space and a minimum of nine inches clear toe
space (see ADAAG 4.19.2). If neither clear floor space and Minimum Quantity 1
knee and toe clearance can be provided, remove the sink Maximum Quantity: 1
cabinet and replace with an accessible wall-mounted sink unit.
Unit: Each
Minimum Estimated Cost: 420
Maximum Estimated Cost: 420
Record Number 185
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 49 of 542


Facility Name: San Joaquin Fairgrounds
Path of Travel
Finding: The pipes under the sink in Building 8 do not provide protection
against contact.

Alternative *
Rec:
(Where
Available)

Sink in Building 8

Full Rec Insulate or otherwise configure pipes under the sink designated Citation ADAAG 4.19.4
to be accessible in the room to protect against contact (see
ADAAG 4.19.4). Make certain there are no sharp or abrasive
surfaces under the sink. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 39
Maximum Estimated Cost: 39
Record Number 186
Priority:

Path of Travel
Finding: The faucet controls on the sink in Building 8 require tight
grasping, pinching, or twisting of the wrist and are not
accessible.

Alternative *
Rec:
(Where
Available)

Sink in Building 8

Full Rec Install faucet controls complying with ADAAG 4.19.5 on the sink Citation ADAAG 4.19.5
designated to be accessible in Building 8. Lever-operated, push-
type, touch-type or electronically controlled mechanisms are
acceptable elements (see ADAAG 4.19.5). If self-closing valves Minimum Quantity 1
are used the faucet shall remain open for at least 10 seconds. Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 392
Maximum Estimated Cost: 392
Record Number 187
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 50 of 542


Facility Name: San Joaquin Fairgrounds
Path of Travel
Finding: The sink in the Administration Office is in an enclosed cabinet,
thereby preventing an accessible forward approach. The height
of the counter surface is greater than 34 inches above the
finished floor.

Alternative *
Rec:
(Where
Available)

Sink in the Administration Office

Full Rec Sinks in rooms must provide clear floor space in front of the sink Citation ADAAG 4.19.3
for an accessible forward approach and shall provide at least 27
inches clear knee space and a minimum of nine inches clear toe
space (see ADAAG 4.19.2). If neither clear floor space and Minimum Quantity 1
knee and toe clearance can be provided, remove the sink Maximum Quantity: 1
cabinet and replace with an accessible wall-mounted sink unit.
Unit: Each
Minimum Estimated Cost: 420
Maximum Estimated Cost: 420
Record Number 182
Priority:

Path of Travel
Finding: The pipes under the sink in the Administration Building do not
provide protection against contact.

Alternative *
Rec:
(Where
Available)

Sink in the Administration Office

Full Rec Insulate or otherwise configure pipes under the sink designated Citation ADAAG 4.19.4
to be accessible in the room to protect against contact (see
ADAAG 4.19.4). Make certain there are no sharp or abrasive
surfaces under the sink. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 39
Maximum Estimated Cost: 39
Record Number 183
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 51 of 542


Facility Name: San Joaquin Fairgrounds
Path of Travel
Finding: The sink in the Jockey's Quarters is in an enclosed cabinet,
thereby preventing an accessible forward approach. The height
of the counter surface is greater than 34 inches above the
finished floor.

Alternative *
Rec:
(Where
Available)

Sink in the Jockeys Quarters

Full Rec Sinks in rooms must provide clear floor space in front of the sink Citation ADAAG 4.19.3
for an accessible forward approach and shall provide at least 27
inches clear knee space and a minimum of nine inches clear toe
space (see ADAAG 4.19.2). If neither clear floor space and Minimum Quantity 1
knee and toe clearance can be provided, remove the sink Maximum Quantity: 1
cabinet and replace with an accessible wall-mounted sink unit.
Unit: Each
Minimum Estimated Cost: 420
Maximum Estimated Cost: 420
Record Number 155
Priority:

Path of Travel
Finding: The pipes under the sink in the Jockey's Quarters do not
provide protection against contact.

Alternative *
Rec:
(Where
Available)

Sink in the Jockeys Quarters

Full Rec Insulate or otherwise configure pipes under the sink designated Citation ADAAG 4.19.4
to be accessible in the room to protect against contact (see
ADAAG 4.19.4). Make certain there are no sharp or abrasive
surfaces under the sink. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 39
Maximum Estimated Cost: 39
Record Number 156
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 52 of 542


Facility Name: San Joaquin Fairgrounds
Path of Travel
Finding: The knee clearance space under the sink designated to be
accessible in the Jockey's Quarters is less than 27 inches.

Alternative *
Rec:
(Where
Available)

Sink in the Jockey's Quarters

Full Rec Raise or replace the sink designated to be accessible in the Citation ADAAG 4.19.2
restroom to provide at least 27 inches of clear knee space and a
minimum of nine inches clear toe space.
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1286
Maximum Estimated Cost: 1286
Record Number 206
Priority:

Path of Travel
Finding: The faucet controls on the sink in the Jockey's Quarters require
tight grasping, pinching, or twisting of the wrist and are not
accessible.

Alternative *
Rec:
(Where
Available)

Sink in the Jockey's Quarters

Full Rec Install faucet controls complying with ADAAG 4.19.5 on the sink Citation ADAAG 4.19.5
designated to be accessible in the Jockey's Quarters. Lever-
operated, push-type, touch-type or electronically controlled
mechanisms are acceptable elements (see ADAAG 4.19.5). If Minimum Quantity 1
self-closing valves are used the faucet shall remain open for at Maximum Quantity: 1
least 10 seconds.
Unit: Each
Minimum Estimated Cost: 392
Maximum Estimated Cost: 392
Record Number 207
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 53 of 542


Facility Name: San Joaquin Fairgrounds
Path of Travel
Finding: The height of the counter surface of the sink designated to be
accessible in the Linden Lions Building is greater than 34 inches
above the finished floor.

Alternative *
Rec:
(Where
Available)

Sink in the Linden Lion's Building

Full Rec Relocate the sink designated to be accessible in the room to Citation ADAAG 4.19.2
provide a maximum counter surface height of no greater than 34
inches above the finished floor (see ADAAG 4.19.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1286
Maximum Estimated Cost: 1286
Record Number 208
Priority:

Path of Travel
Finding: The pipes under the sink in the Linden Lion's Building do not
provide protection against contact.

Alternative *
Rec:
(Where
Available)

Sink in the Linden Lion's Building

Full Rec Insulate or otherwise configure pipes under the sink designated Citation ADAAG 4.19.4
to be accessible in the room to protect against contact (see
ADAAG 4.19.4). Make certain there are no sharp or abrasive
surfaces under the sink. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 39
Maximum Estimated Cost: 39
Record Number 209
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 54 of 542


Facility Name: San Joaquin Fairgrounds
Path of Travel
Finding: The faucet controls on the sink in the Linden Lion's Building
require tight grasping, pinching, or twisting of the wrist and are
not accessible.

Alternative *
Rec:
(Where
Available)

Sink in the Linden Lion's Building

Full Rec Install faucet controls complying with ADAAG 4.19.5 on the sink Citation ADAAG 4.19.5
designated to be accessible in the Linden Lion's Building. Lever-
operated, push-type, touch-type or electronically controlled
mechanisms are acceptable elements (see ADAAG 4.19.5). If Minimum Quantity 1
self-closing valves are used the faucet shall remain open for at Maximum Quantity: 1
least 10 seconds.
Unit: Each
Minimum Estimated Cost: 392
Maximum Estimated Cost: 392
Record Number 210
Priority:

Path of Travel
Finding: The knee clearance space under the sink designated to be
accessible in the Maintenance Building is less than 27 inches.

Alternative *
Rec:
(Where
Available)

Sink in the Maintenance Building (East End)

Full Rec Raise or replace the sink designated to be accessible to provide Citation ADAAG 4.19.2
at least 27 inches of clear knee space and a minimum of nine
inches clear toe space (see ADAAG 4.19.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1286
Maximum Estimated Cost: 1286
Record Number 161
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 55 of 542


Facility Name: San Joaquin Fairgrounds
Path of Travel
Finding: The height of the counter surface of the sink designated to be
accessible in the Maintenance Building is greater than 34
inches above the finished floor.

Alternative *
Rec:
(Where
Available)

Sink in the Maintenance Building (East End)

Full Rec Relocate the sink designated to be accessible in the room to Citation ADAAG 4.19.2
provide a maximum counter surface height of no greater than 34
inches above the finished floor (see ADAAG 4.19.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1286
Maximum Estimated Cost: 1286
Record Number 162
Priority:

Path of Travel
Finding: The faucet controls on the sink in the Maintenance Building
require tight grasping, pinching, or twisting of the wrist and are
not accessible.

Alternative *
Rec:
(Where
Available)

Sink in the Maintenance Building (East End)

Full Rec Install faucet controls complying with ADAAG 4.19.5 on the sink Citation ADAAG 4.19.5
designated to be accessible in the Maintenance Building. Lever-
operated, push-type, touch-type or electronically controlled
mechanisms are acceptable elements (see ADAAG 4.19.5). If Minimum Quantity 1
self-closing valves are used the faucet shall remain open for at Maximum Quantity: 1
least 10 seconds.
Unit: Each
Minimum Estimated Cost: 392
Maximum Estimated Cost: 392
Record Number 163
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 56 of 542


Facility Name: San Joaquin Fairgrounds
Path of Travel
Finding: The sink in the Maintenance Office is in an enclosed cabinet,
thereby preventing an accessible forward approach. The height
of the counter surface is greater than 34 inches above the
finished floor.

Alternative *
Rec:
(Where
Available)

Sink in the Maintenance Office

Full Rec Sinks in rooms must provide clear floor space in front of the sink Citation ADAAG 4.19.3
for an accessible forward approach and shall provide at least 27
inches clear knee space and a minimum of nine inches clear toe
space (see ADAAG 4.19.2). If neither clear floor space and Minimum Quantity 1
knee and toe clearance can be provided, remove the sink Maximum Quantity: 1
cabinet and replace with an accessible wall-mounted sink unit.
Unit: Each
Minimum Estimated Cost: 420
Maximum Estimated Cost: 420
Record Number 191
Priority:

Path of Travel
Finding: The pipes under the sink in the Maintenance Office do not
provide protection against contact.

Alternative *
Rec:
(Where
Available)

Sink in the Maintenance Office

Full Rec Insulate or otherwise configure pipes under the sink designated Citation ADAAG 4.19.4
to be accessible in the room to protect against contact (see
ADAAG 4.19.4). Make certain there are no sharp or abrasive
surfaces under the sink. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 39
Maximum Estimated Cost: 39
Record Number 192
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 57 of 542


Facility Name: San Joaquin Fairgrounds
Path of Travel
Finding: The mat at the east entrance to the Stable Office does not
adhere to the underlying floor surface and creates a hazardous
path of travel.

Alternative *
Rec:
(Where
Available)

Stable Office (East Entrance)

Full Rec Securely fasten the mats or replace with a mat that grips to the Citation CBC 1124B.3; ADAAG 4.5.3
underlying floor surface to provide a firm, stable, continuous and
relatively smooth path of travel surface (see CBC 1124B.3 and
ADAAG 4.5.3). Mats along the primary path of travel shall Minimum Quantity 1
provide beveled edges on all sides to prevent roll over. Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 659
Maximum Estimated Cost: 659
Record Number 160
Priority:

Path of Travel
Finding: The mat at the entrance to the Stable Office does not adhere to
the underlying floor surface and creates a hazardous path of
travel.

Alternative *
Rec:
(Where
Available)

Stable Office Main Entrance

Full Rec Securely fasten the mats or replace with a mat that grips to the Citation CBC 1124B.3; ADAAG 4.5.3
underlying floor surface to provide a firm, stable, continuous and
relatively smooth path of travel surface (see CBC 1124B.3 and
ADAAG 4.5.3). Mats along the primary path of travel shall Minimum Quantity 1
provide beveled edges on all sides to prevent roll over. Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 659
Maximum Estimated Cost: 659
Record Number 158
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 58 of 542


Facility Name: San Joaquin Fairgrounds
Path of Travel
Finding: The knee space at the tables in the gambling area is less than
19 inches deep.

Alternative *
Rec:
(Where
Available)

Winner's Gaming and Sports Emporium

Full Rec Modify or replace one of the tables in the gambling area to Citation CBC 1122B.3; ADAAG 4.32.2; ADAAG 4.32.5(2)
provide knee clearance of at least 27 inches in height, 30 inches
in width and 19 inches in depth (see CBC 1122B.3, ADAAG
4.32.2 and ADAAG Figure 45). The table top height shall not Minimum Quantity 1
exceed 34 inches above the finished floor. Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 174
Maximum Estimated Cost: 174
Record Number 1160
Priority:

Path of Travel
Finding: The knee space at the tables in the Champion's Section is less
than 19 inches deep.

Alternative *
Rec:
(Where
Available)

Winner's Gaming and Sports Emporium

Full Rec Modify or replace one of the tables in the Champion's Section to Citation CBC 1122B.3; ADAAG 4.32.2; ADAAG 4.32.5(2)
provide knee clearance of at least 27 inches in height, 30 inches
in width and 19 inches in depth (see CBC 1122B.3, ADAAG
4.32.2 and ADAAG Figure 45). The table top height shall not Minimum Quantity 1
exceed 34 inches above the finished floor. Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 174
Maximum Estimated Cost: 174
Record Number 1168
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 59 of 542


Facility Name: San Joaquin Fairgrounds
Ramps
Finding: The slope of the ramp is greater than 8.33%.

Alternative *
Rec:
(Where
Available)

Exterior Ramp to Building 7

Full Rec Modify the run of the ramp to provide a slope no greater than Citation CBC 1133B.5.3; ADAAG 4.8
8.33% with a cross slope not exceeding 2% (see CBC
1133B.5.3 and ADAAG 4.8.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: 60 Linear Feet
Minimum Estimated Cost: 4920
Maximum Estimated Cost: 4920
Record Number 225
Priority:

Ramps
Finding: The width of the run of the ramp is less than 48 inches.

Alternative *
Rec:
(Where
Available)

Exterior Ramp to Building 7

Full Rec Widen the run of the ramp so that it has a minimum clear width Citation CBC 1133B.5.2
of 48 inches (see CBC 1133B.5.2.2).

Minimum Quantity 1
Maximum Quantity: 1
Unit: 60 Linear Feet
Minimum Estimated Cost: 7500
Maximum Estimated Cost: 7500
Record Number 226
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 60 of 542


Facility Name: San Joaquin Fairgrounds
Ramps
Finding: There is only one handrail provided on the ramp. There are no
12-inch extensions beyond the top and bottom of the ramp.

Alternative *
Rec:
(Where
Available)

Exterior Ramp to Building 7

Full Rec Install a handrail on each side of the ramp that provide a Citation CBC 1133B.5.5; ADAAG 4.8.5
continuous and smooth gripping surface diameter between 1 1/4
inches to 1 7/8 inches, mounted at a height between 34 inches
and 38 inches and shall be at a distance no less than 1 1/2 Minimum Quantity 1
inches from the adjacent wall. The ends of the handrail shall Maximum Quantity: 1
extend 12 inches in a parallel height from the top and bottom of
the ramp and return smoothly to the post or wall. Unit: Each
Minimum Estimated Cost: 1200
Maximum Estimated Cost: 1200
Record Number 227
Priority:

Ramps
Finding: The slope of the concrete ramp is greater than 8.33%.

Alternative *
Rec:
(Where
Available)

Exterior Ramp to the Bleachers at the Grandstands

Full Rec Modify the run of the concrete ramp to provide a slope no Citation CBC 1133B.5.3; ADAAG 4.8
greater than 8.33% with a cross slope not exceeding 2% (see
CBC 1133B.5.3 and ADAAG 4.8.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: 60 Linear Feet
Minimum Estimated Cost: 4920
Maximum Estimated Cost: 4920
Record Number 223
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 61 of 542


Facility Name: San Joaquin Fairgrounds
Ramps
Finding: The ends of the handrails end abruptly.

Alternative *
Rec:
(Where
Available)

Exterior Ramp to the Bleachers at the Grandstands

Full Rec Replace the handrails on each side of the ramp that return Citation CBC 1133B.5.5; ADAAG 4.8.5
smoothly to the post or wall.

Minimum Quantity 1
Maximum Quantity: 1
Unit: 60 Linear Feet
Minimum Estimated Cost: 1320
Maximum Estimated Cost: 1320
Record Number 224
Priority:

Ramps
Finding: The slope of the bottom run of the metal ramp is greater than
8.33%.

Alternative *
Rec:
(Where
Available)

Exterior Ramp to the Bleachers at the Speedway (East


End)

Full Rec Modify the bottom run of the metal ramp to provide a slope no Citation CBC 1133B.5.3; ADAAG 4.8
greater than 8.33% with a cross slope not exceeding 2% (see
CBC 1133B.5.3 and ADAAG 4.8.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: 60 Linear Feet
Minimum Estimated Cost: 4920
Maximum Estimated Cost: 4920
Record Number 238
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 62 of 542


Facility Name: San Joaquin Fairgrounds
Ramps
Finding: The width of the run of each run of the metal ramp is less than
48 inches.

Alternative *
Rec:
(Where
Available)

Exterior Ramp to the Bleachers at the Speedway (East


End)

Full Rec Widen each run of the metal ramp so that it has a minimum Citation CBC 1133B.5.2
clear width of 48 inches (see CBC 1133B.5.2.2).

Minimum Quantity 1
Maximum Quantity: 1
Unit: 60 Linear Feet
Minimum Estimated Cost: 7500
Maximum Estimated Cost: 7500
Record Number 239
Priority:

Ramps
Finding: The ramp changes direction more than 30 degrees. The length
of the intermediate turn landing on the ramp is less than 72
inches. The width of the intermediate landing is less than 60
inches.

Alternative *
Rec:
(Where
Available)

Exterior Ramp to the Bleachers at the Speedway (East


End)

Full Rec Modify or replace the intermediate turn landing on the ramp to Citation CBC 1133B.5.4; ADAAG 4.8
provide at least 72 inches in length in the direction of the run of
the ramp and 60 inches in width (see CBC 1133B.5.4.6 and
ADAAG 4.8.4). Minimum Quantity 1
Maximum Quantity: 1
Unit: None Selected
Minimum Estimated Cost: 0
Maximum Estimated Cost: 1872
Record Number 240
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 63 of 542


Facility Name: San Joaquin Fairgrounds
Ramps
Finding: The handrails are mounted at a height less than 34 inches.
There are no 12-inch extensions beyond the top and bottom
right of the ramp. The gripping surface of the handrails are
interrupted by posts.

Alternative *
Rec:
(Where
Available)

Exterior Ramp to the Bleachers at the Speedway (East


End)

Full Rec Replace the handrails on each side of the ramp to provide a Citation CBC 1133B.5.5; ADAAG 4.8.5
height between 34 inches and 38 inches. The gripping surface
shall be smooth and free from interruptions. The handrails shall
provide 12-inch extensions, extending beyond the top and Minimum Quantity 1
bottom of the ramp, that are parallel to the ground surface and Maximum Quantity: 1
return smoothly to the post or wall.
Unit: 60 Linear Feet
Minimum Estimated Cost: 1320
Maximum Estimated Cost: 1320
Record Number 241
Priority:

Ramps
Finding: The slope of the bottom run of the metal ramp is greater than
8.33%.

Alternative *
Rec:
(Where
Available)

Exterior Ramp to the Bleachers at the Speedway (West


End)

Full Rec Modify the bottom run of the metal ramp to provide a slope no Citation CBC 1133B.5.3; ADAAG 4.8
greater than 8.33% with a cross slope not exceeding 2% (see
CBC 1133B.5.3 and ADAAG 4.8.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: 60 Linear Feet
Minimum Estimated Cost: 4920
Maximum Estimated Cost: 4920
Record Number 242
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 64 of 542


Facility Name: San Joaquin Fairgrounds
Ramps
Finding: The width of the run of the metal ramp is less than 48 inches.

Alternative *
Rec:
(Where
Available)

Exterior Ramp to the Bleachers at the Speedway (West


End)

Full Rec Widen the run of the metal ramp so that it has a minimum clear Citation CBC 1133B.5.2
width of 48 inches (see CBC 1133B.5.2.2).

Minimum Quantity 1
Maximum Quantity: 1
Unit: 60 Linear Feet
Minimum Estimated Cost: 7500
Maximum Estimated Cost: 7500
Record Number 243
Priority:

Ramps
Finding: The ramp changes direction more than 30 degrees. The length
of the intermediate turn landing on the ramp is less than 72
inches. The width of the intermediate landing is less than 60
inches.

Alternative *
Rec:
(Where
Available)

Exterior Ramp to the Bleachers at the Speedway (West


End)

Full Rec Modify or replace the intermediate turn landing on the ramp to Citation CBC 1133B.5.4; ADAAG 4.8
provide at least 72 inches in length in the direction of the run of
the ramp and 60 inches in width (see CBC 1133B.5.4.6 and
ADAAG 4.8.4). Minimum Quantity 1
Maximum Quantity: 1
Unit: None Selected
Minimum Estimated Cost: 0
Maximum Estimated Cost: 1872
Record Number 244
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 65 of 542


Facility Name: San Joaquin Fairgrounds
Ramps
Finding: The handrails are mounted at a height less than 34 inches.
There are no 12-inch extensions beyond the top and bottom
right of the ramp. The gripping surface of the handrails are
interrupted by posts.

Alternative *
Rec:
(Where
Available)

Exterior Ramp to the Bleachers at the Speedway (West


End)

Full Rec Replace the handrails on each side of the ramp to provide a Citation CBC 1133B.5.5; ADAAG 4.8.5
height between 34 inches and 38 inches. The gripping surface
shall be smooth and free from interruptions. The handrails shall
provide 12-inch extensions, extending beyond the top and Minimum Quantity 1
bottom of the ramp, that are parallel to the ground surface and Maximum Quantity: 1
return smoothly to the post or wall.
Unit: 60 Linear Feet
Minimum Estimated Cost: 1320
Maximum Estimated Cost: 1320
Record Number 245
Priority:

Ramps
Finding: The slope of the concrete ramp is greater than 8.33%.

Alternative *
Rec:
(Where
Available)

Exterior Ramp to the Milk Parlor

Full Rec Modify the run of the concrete ramp to provide a slope no Citation CBC 1133B.5.3; ADAAG 4.8
greater than 8.33% with a cross slope not exceeding 2% (see
CBC 1133B.5.3 and ADAAG 4.8.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: 60 Linear Feet
Minimum Estimated Cost: 4920
Maximum Estimated Cost: 4920
Record Number 235
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 66 of 542


Facility Name: San Joaquin Fairgrounds
Ramps
Finding: There is no top landing on the ramp.

Alternative *
Rec:
(Where
Available)

Exterior Ramp to the Milk Parlor

Full Rec Modify or replace the ramp so that it has a top landing Citation CBC 1133B.4.1; ADAAG 4.8.4(2)
complying with CBC 1133B.4.1 and ADAAG 4.8.4.

Minimum Quantity 1
Maximum Quantity: 1
Unit: None Selected
Minimum Estimated Cost: 0
Maximum Estimated Cost: 1872
Record Number 236
Priority:

Ramps
Finding: The handrails are mounted at a height greater than 38 inches.
There are no 12-inch extensions beyond the top right and
bottom of the ramp. The gripping surface of the right handrail is
interrupted by a post.

Alternative *
Rec:
(Where
Available)

Exterior Ramp to the Milk Parlor

Full Rec Replace the handrails on each side of the ramp to provide a Citation CBC 1133B.5.5; ADAAG 4.8.5
height between 34 inches and 38 inches. The gripping surface
shall be smooth and free from interruptions. The handrails shall
provide 12-inch extensions, extending beyond the top and Minimum Quantity 1
bottom of the ramp, that are parallel to the ground surface and Maximum Quantity: 1
return smoothly to the post or wall.
Unit: 60 Linear Feet
Minimum Estimated Cost: 1320
Maximum Estimated Cost: 1320
Record Number 237
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 67 of 542


Facility Name: San Joaquin Fairgrounds
Ramps
Finding: The slope of the concrete ramp is greater than 8.33%.

Alternative *
Rec:
(Where
Available)

Exterior Ramp to the Restrooms at the Speedway (East


Side)

Full Rec Modify the run of the concrete ramp to provide a slope no Citation CBC 1133B.5.3; ADAAG 4.8
greater than 8.33% with a cross slope not exceeding 2% (see
CBC 1133B.5.3 and ADAAG 4.8.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: 60 Linear Feet
Minimum Estimated Cost: 4920
Maximum Estimated Cost: 4920
Record Number 228
Priority:

Ramps
Finding: The distance between the latch side of the door on a side
approach from the top landing is less than 42 inches.

Alternative *
Rec:
(Where
Available)

Exterior Ramp to the Restrooms at the Speedway (East


Side)

Full Rec Modify or replace the top landing on the ramp to provide at least Citation CBC 1133B.4.2; ADAAG 4.8
42 inches distance between the latch side of the door and the
side of the landing to accommodate the required side approach
to the entrance door (see CBC 1133B.5.4.2 and ADAAG Minimum Quantity 1
4.8.4(2)). Maximum Quantity: 1
Unit: 48 Square Feet
Minimum Estimated Cost: 1872
Maximum Estimated Cost: 1872
Record Number 229
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 68 of 542


Facility Name: San Joaquin Fairgrounds
Ramps
Finding: There are no 12-inch extensions beyond the top right and
bottom of the ramp. The ends of the right handrail end abruptly.

Alternative *
Rec:
(Where
Available)

Exterior Ramp to the Restrooms at the Speedway (East


Side)

Full Rec Weld pipe extensions on the handrails of the ramp so that they Citation CBC 1133B.5.5; ADAAG 4.8
continue 12 inches beyond the end of the ramp parallel to the
ground surface and return smoothly to the post or wall (see CBC
1133B.5.5 and ADAAG 4.8.5). Minimum Quantity 1
Maximum Quantity: 1
Unit: 60 Linear Feet
Minimum Estimated Cost: 2400
Maximum Estimated Cost: 2400
Record Number 230
Priority:

Ramps
Finding: The width of the run of the wood ramp is less than 48 inches.

Alternative *
Rec:
(Where
Available)

Exterior Ramp to the Restrooms at the Speedway (West


Side)

Full Rec Widen the run of the wood ramp so that it has a minimum clear Citation CBC 1133B.5.2
width of 48 inches (see CBC 1133B.5.2.2).

Minimum Quantity 1
Maximum Quantity: 1
Unit: 60 Linear Feet
Minimum Estimated Cost: 8383
Maximum Estimated Cost: 8383
Record Number 231
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 69 of 542


Facility Name: San Joaquin Fairgrounds
Ramps
Finding: The length of the top landing on the ramp is less than 60 inches.

Alternative *
Rec:
(Where
Available)

Exterior Ramp to the Restrooms at the Speedway (West


Side)

Full Rec Modify or replace the top landing on the ramp to provide a top Citation CBC 1133B.4.2; ADAAG 4.8
landing that exceeds 60 inches in length (see CBC 1133B.5.4.2
and ADAAG 4.8.4(2)).
Minimum Quantity 1
Maximum Quantity: 1
Unit: 48 Square Feet
Minimum Estimated Cost: 1872
Maximum Estimated Cost: 1872
Record Number 232
Priority:

Ramps
Finding: The slope of the bottom landing is greater than 2%.

Alternative *
Rec:
(Where
Available)

Exterior Ramp to the Restrooms at the Speedway (West


Side)

Full Rec Resurface the bottom landing of the ramp to provide a level Citation CBC 1133B.4.5; ADAAG 4.8
surface not exceeding a slope greater than 2% (see CBC
1133B.5.4.5).
Minimum Quantity 1
Maximum Quantity: 1
Unit: 48 Square Feet
Minimum Estimated Cost: 1872
Maximum Estimated Cost: 1872
Record Number 233
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 70 of 542


Facility Name: San Joaquin Fairgrounds
Ramps
Finding: The handrails are mounted at a height less than 34 inches. The
12-inch extensions beyond the bottom of the ramp are not
parallel to the ground surface.

Alternative *
Rec:
(Where
Available)

Exterior Ramp to the Restrooms at the Speedway (West


Side)

Full Rec Replace the handrails on each side of the ramp to provide a Citation CBC 1133B.5.5; ADAAG 4.8.5
height between 34 inches and 38 inches. The handrails shall
provide 12-inch extensions, extending beyond the top and
bottom of the ramp, that are parallel to the ground surface and Minimum Quantity 1
return smoothly to the post or wall. Maximum Quantity: 1
Unit: 60 Linear Feet
Minimum Estimated Cost: 1320
Maximum Estimated Cost: 1320
Record Number 234
Priority:

Platform Lifts
Finding: There is a platform lift at the Grandstands. The platform lift
provides accessible vertical path of travel to the bleachers. The
platform lift is capable of providing independent operation.

Alternative *
Rec:
(Where
Available)

Platform Lift at the Grandstands

Full Rec Platform lifts must be capable of independent operation. Citation CBC 1105.3; CBC 1104.1.4; ADAAG 4.11
Platform lifts shall not modified in any manner or serve as an
accessible means of egress. Platform lifts shall comply with
CBC 1105.3, CBC 1104.1.4, ADAAG 4.11 and ASME A17.1 Minimum Quantity 1
Safety Code for Elevators and Escalators, Section XX, 1990. Maximum Quantity: 1
Unit: None Selected
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 246
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 71 of 542


Facility Name: San Joaquin Fairgrounds
Platform Lifts
Finding: There is no level landing provided at the entrance to the
platform lift.

Alternative *
Rec:
(Where
Available)

Platform Lift at the Grandstands

Full Rec Provide a level and clear landing at least 60 inches in length in Citation CBC 1133B.2.4.2; ADAAG 4.13.6
the direction of the door swing.

Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 247
Priority:

Stairs
Finding: There is no detectable striping on each tread of the exterior
stairway.

Alternative *
Rec:
(Where
Available)

Exterior Stairs to Building 7

Full Rec Affix detectable contrasting striping to each tread of the stairway Citation CBC 1006.16.1; CBC 11133B.4.4; ADAAG 4.9.5
that clearly contrasts in color from the tread and is at least 2
inches in width placed no more than 1 inch from the tread nose
or landing. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 144
Maximum Estimated Cost: 144
Record Number 255
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 72 of 542


Facility Name: San Joaquin Fairgrounds
Stairs
Finding: The width of the exterior stairway is less than 48 inches.

Alternative *
Rec:
(Where
Available)

Exterior Stairs to Building 7

Full Rec Install an exterior stairway with a minimum width of 48 inches Citation CBC 1006.2
(see CBC 1006.2).

Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 4672
Maximum Estimated Cost: 4672
Record Number 256
Priority:

Stairs
Finding: There is only one handrail on the stairway. The handrail does
not provide 12-inch extensions beyond the top treads.

Alternative *
Rec:
(Where
Available)

Exterior Stairs to Building 7

Full Rec Install handrails on each side of stairway that provide a gripping Citation CBC 1133B.4.2; ADAAG 4.9.4
surface between 1 1/4 to 1 7/8 inches with 12-inch top and
bottom handrail extensions that extend beyond the top and
bottom treads of the stairway which are parallel to the ground Minimum Quantity 1
surface and return smoothly to the post or wall. Handrails shall Maximum Quantity: 1
be mounted at a height between 34 and 38 inches at a distance
no less than 1 1/2 inches from the adjacent wall. Unit: 24 Linear Feet
Minimum Estimated Cost: 528
Maximum Estimated Cost: 528
Record Number 257
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 73 of 542


Facility Name: San Joaquin Fairgrounds
Stairs
Finding: The top riser on the stairway is open.

Alternative *
Rec:
(Where
Available)

Exterior Stairs to Building 7

Full Rec Close the riser openings on the stairway (see CBC 1006.16.3 Citation CBC 1133B.4.5.3; ADAAG 4.9.2
and ADAAG 4.9.2). Open risers are not permitted.

Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 480
Maximum Estimated Cost: 480
Record Number 258
Priority:

Stairs
Finding: There is no detectable striping on each tread of the exterior
stairway.

Alternative *
Rec:
(Where
Available)

Exterior Stairs to the Annex Next to the Jockey's Quarters

Full Rec Affix detectable contrasting striping to each tread of the stairway Citation CBC 1006.16.1; CBC 11133B.4.4; ADAAG 4.9.5
that clearly contrasts in color from the tread and is at least 2
inches in width placed no more than 1 inch from the tread nose
or landing. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 144
Maximum Estimated Cost: 144
Record Number 261
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 74 of 542


Facility Name: San Joaquin Fairgrounds
Stairs
Finding: The width of the exterior stairway is less than 48 inches.

Alternative *
Rec:
(Where
Available)

Exterior Stairs to the Annex Next to the Jockey's Quarters

Full Rec Install an exterior stairway with a minimum width of 48 inches Citation CBC 1006.2
(see CBC 1006.2).

Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 4672
Maximum Estimated Cost: 4672
Record Number 262
Priority:

Stairs
Finding: The handrails do not provide 12-inch extensions beyond the top
and bottom treads. The diameter of the gripping surface is
greater than 1 7/8 inches. The handrails are mounted at a
height less than 34 inches.

Alternative *
Rec:
(Where
Available)

Exterior Stairs to the Annex Next to the Jockey's Quarters

Full Rec Install handrails on each side of stairway that provide a gripping Citation CBC 1133B.4.2; ADAAG 4.9.4
surface between 1 1/4 to 1 7/8 inches with 12-inch top and
bottom handrail extensions that extend beyond the top and
bottom treads of the stairway which are parallel to the ground Minimum Quantity 1
surface and return smoothly to the post or wall. Handrails shall Maximum Quantity: 1
be mounted at a height between 34 and 38 inches at a distance
no less than 1 1/2 inches from the adjacent wall. Unit: 24 Linear Feet
Minimum Estimated Cost: 528
Maximum Estimated Cost: 528
Record Number 263
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 75 of 542


Facility Name: San Joaquin Fairgrounds
Stairs
Finding: Detectable striping is provided on the top two and bottom two
treads only.

Alternative *
Rec:
(Where
Available)

Exterior Stairs to the Grandstands

Full Rec Affix detectable contrasting striping to each tread of the stairway Citation CBC 1006.16.1; CBC 11133B.4.4; ADAAG 4.9.5
that clearly contrasts in color from the tread and is at least 2
inches in width placed no more than 1 inch from the tread nose
or landing. Minimum Quantity 1
Maximum Quantity: 6
Unit: Each
Minimum Estimated Cost: 144
Maximum Estimated Cost: 864
Record Number 252
Priority:

Stairs
Finding: The handrails do not provide 12-inch extensions beyond the top
and bottom treads.

Alternative *
Rec:
(Where
Available)

Exterior Stairs to the Grandstands

Full Rec Install handrails on each side of stairway that provide 12-inch Citation CBC 1133B.4.2; ADAAG 4.9.4
top and bottom handrail extensions that extend beyond the top
and bottom treads of the stairway which are parallel to the
ground surface and return smoothly to the post or wall. Minimum Quantity 1
Maximum Quantity: 6
Unit: 24 Linear Feet
Minimum Estimated Cost: 528
Maximum Estimated Cost: 3168
Record Number 253
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 76 of 542


Facility Name: San Joaquin Fairgrounds
Stairs
Finding: Two of the exterior stairways do not provide handrails on each
side of the bottom run of the stairway.

Alternative *
Rec:
(Where
Available)

Exterior Stairs to the Grandstands

Full Rec Install handrails on each side of stairway that provide a gripping Citation CBC 1133B.4.2; ADAAG 4.9.4
surface between 1 1/4 to 1 7/8 inches with 12-inch top and
bottom handrail extensions that extend beyond the top and
bottom treads of the stairway which are parallel to the ground Minimum Quantity 1
surface and return smoothly to the post or wall. Handrails shall Maximum Quantity: 2
be mounted at a height between 34 and 38 inches at a distance
no less than 1 1/2 inches from the adjacent wall. Unit: 24 Linear Feet
Minimum Estimated Cost: 528
Maximum Estimated Cost: 1056
Record Number 254
Priority:

Stairs
Finding: There is no detectable striping on each tread of the exterior
stairway.

Alternative *
Rec:
(Where
Available)

Exterior Stairs to the Office at the Stockton Motorplex

Full Rec Affix detectable contrasting striping to each tread of the stairway Citation CBC 1006.16.1; CBC 11133B.4.4; ADAAG 4.9.5
that clearly contrasts in color from the tread and is at least 2
inches in width placed no more than 1 inch from the tread nose
or landing. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 144
Maximum Estimated Cost: 144
Record Number 248
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 77 of 542


Facility Name: San Joaquin Fairgrounds
Stairs
Finding: The width of the exterior stairway is less than 48 inches.

Alternative *
Rec:
(Where
Available)

Exterior Stairs to the Office at the Stockton Motorplex

Full Rec Install an exterior stairway with a minimum width of 48 inches Citation CBC 1006.2
(see CBC 1006.2).

Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 4672
Maximum Estimated Cost: 4672
Record Number 249
Priority:

Stairs
Finding: The handrails do not provide 12-inch extensions beyond the
bottom treads. The handrails are mounted at a height greater
than 38 inches.

Alternative *
Rec:
(Where
Available)

Exterior Stairs to the Office at the Stockton Motorplex

Full Rec Install handrails on each side of stairway that provide 12-inch Citation CBC 1133B.4.2; ADAAG 4.9.4
top and bottom handrail extensions that extend beyond the top
and bottom treads of the stairway which are parallel to the
ground surface and return smoothly to the post or wall. Minimum Quantity 1
Handrails shall be mounted at a height between 34 and 38 Maximum Quantity: 1
inches at a distance no less than 1 1/2 inches from the adjacent
wall. Unit: 24 Linear Feet
Minimum Estimated Cost: 528
Maximum Estimated Cost: 528
Record Number 250
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 78 of 542


Facility Name: San Joaquin Fairgrounds
Stairs
Finding: The risers on the stairway are open.

Alternative *
Rec:
(Where
Available)

Exterior Stairs to the Office at the Stockton Motorplex

Full Rec Close the riser openings on the stairway (see CBC 1006.16.3 Citation CBC 1133B.4.5.3; ADAAG 4.9.2
and ADAAG 4.9.2). Open risers are not permitted.

Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 480
Maximum Estimated Cost: 480
Record Number 251
Priority:

Doors
Finding: The bottom 10 inches of the door from the lobby to the east
wing does not provide a smooth, uninterrupted surface, or panel
to allow the door to be opened by a wheelchair footrest without
creating a trap or hazardous condition, due to the door stop.

Alternative *
Rec:
(Where
Available)

Administration Office

Full Rec Install a panel or replace the door to provide a smooth, Citation CBC 1133B.2.6
uninterrupted surface for the bottom 10 inches of the door.

Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 264
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 79 of 542


Facility Name: San Joaquin Fairgrounds
Doors
Finding: There is less than 12 inches of latch side clearance from the
push side of the entrance door to the office at the south east
end of the Administration Office.

Alternative *
Rec:
(Where
Available)

Administration Office

Full Rec Consult a design professional to determine if it is technically Citation ADAAG 4.13.6
feasible to provide at least 12 inches of latch side clearance at
the entrance door from the push side (see ADAAG 4.13.6 and
Figure 25). Otherwise, install an automatic door opening device Minimum Quantity 1
to the primary entrance complying with ADAAG 4.13.12 and Maximum Quantity: 1
ANSI/BHMA A156.10, 1985, standards.
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 265
Priority:

Doors
Finding: There is no level landing provided at the entrance door.

Alternative *
Rec:
(Where
Available)

Building 1 (East Entrance)

Full Rec Provide a level and clear landing at least 60 inches in length in Citation CBC 1133B.2.4.2; ADAAG 4.13.6
the direction of the door swing.

Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 268
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 80 of 542


Facility Name: San Joaquin Fairgrounds
Doors
Finding: The bottom 10 inches of the door does not provide a smooth,
uninterrupted surface, or panel to allow the door to be opened
by a wheelchair footrest without creating a trap or hazardous
condition, due to the door stop.

Alternative *
Rec:
(Where
Available)

Building 1 (East Entrance)

Full Rec Install a panel or replace the door to provide a smooth, Citation CBC 1133B.2.6
uninterrupted surface for the bottom 10 inches of the door.

Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 269
Priority:

Doors
Finding: There is no level landing provided at the entrance door.

Alternative *
Rec:
(Where
Available)

Building 1 (North Entrance)

Full Rec Provide a level and clear landing at least 60 inches in length in Citation CBC 1133B.2.4.2; ADAAG 4.13.6
the direction of the door swing.

Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 266
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 81 of 542


Facility Name: San Joaquin Fairgrounds
Doors
Finding: The bottom 10 inches of the door does not provide a smooth,
uninterrupted surface, or panel to allow the door to be opened
by a wheelchair footrest without creating a trap or hazardous
condition, due to the door stop.

Alternative *
Rec:
(Where
Available)

Building 1 (North Entrance)

Full Rec Install a panel or replace the door to provide a smooth, Citation CBC 1133B.2.6
uninterrupted surface for the bottom 10 inches of the door.

Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 267
Priority:

Doors
Finding: There is no level landing provided at the entrance door.

Alternative *
Rec:
(Where
Available)

Building 1 (South Entrance)

Full Rec Provide a level and clear landing at least 60 inches in length in Citation CBC 1133B.2.4.2; ADAAG 4.13.6
the direction of the door swing.

Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 332
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 82 of 542


Facility Name: San Joaquin Fairgrounds
Doors
Finding: The bottom 10 inches of the door does not provide a smooth,
uninterrupted surface, or panel to allow the door to be opened
by a wheelchair footrest without creating a trap or hazardous
condition, due to the door stop.

Alternative *
Rec:
(Where
Available)

Building 1 (South Entrance)

Full Rec Install a panel or replace the door to provide a smooth, Citation CBC 1133B.2.6
uninterrupted surface for the bottom 10 inches of the door.

Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 333
Priority:

Doors
Finding: There is no level landing provided at the entrance door.

Alternative *
Rec:
(Where
Available)

Building 1 (West Entrance)

Full Rec Provide a level and clear landing at least 60 inches in length in Citation CBC 1133B.2.4.2; ADAAG 4.13.6
the direction of the door swing.

Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 270
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 83 of 542


Facility Name: San Joaquin Fairgrounds
Doors
Finding: The bottom 10 inches of the door does not provide a smooth,
uninterrupted surface, or panel to allow the door to be opened
by a wheelchair footrest without creating a trap or hazardous
condition, due to the door stop.

Alternative *
Rec:
(Where
Available)

Building 1 (West Entrance)

Full Rec Install a panel or replace the door to provide a smooth, Citation CBC 1133B.2.6
uninterrupted surface for the bottom 10 inches of the door.

Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 271
Priority:

Doors
Finding: The interior passage door next to the restrooms in Building 2
has a round doorknob, which requires twisting of the wrist to
operate.

Alternative *
Rec:
(Where
Available)

Building 2

Full Rec Interior door hardware (doorknobs) should be changed to Citation ADAAG 4.13.9
accessible lever-handled lockset hardware (see ADAAG 4.13.9).

Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 204
Maximum Estimated Cost: 204
Record Number 285
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 84 of 542


Facility Name: San Joaquin Fairgrounds
Doors
Finding: The bottom 10 inches of the door to the restrooms in Building 2
does not provide a smooth, uninterrupted surface, or panel to
allow the door to be opened by a wheelchair footrest without
creating a trap or hazardous condition, due to the door stop.

Alternative *
Rec:
(Where
Available)

Building 2

Full Rec Install a panel or replace the door to provide a smooth, Citation CBC 1133B.2.6
uninterrupted surface for the bottom 10 inches of the door.

Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 286
Priority:

Doors
Finding: There is no level landing provided at the entrance door.

Alternative *
Rec:
(Where
Available)

Building 2 (North Entrance)

Full Rec Provide a level and clear landing at least 60 inches in length in Citation CBC 1133B.2.4.2; ADAAG 4.13.6
the direction of the door swing.

Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 336
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 85 of 542


Facility Name: San Joaquin Fairgrounds
Doors
Finding: The bottom 10 inches of the door does not provide a smooth,
uninterrupted surface, or panel to allow the door to be opened
by a wheelchair footrest without creating a trap or hazardous
condition, due to the door stops.

Alternative *
Rec:
(Where
Available)

Building 2 (North Entrance)

Full Rec Install a panel or replace the door to provide a smooth, Citation CBC 1133B.2.6
uninterrupted surface for the bottom 10 inches of the door.

Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 337
Priority:

Doors
Finding: The bottom 10 inches of the door does not provide a smooth,
uninterrupted surface, or panel to allow the door to be opened
by a wheelchair footrest without creating a trap or hazardous
condition, due to the door stop.

Alternative *
Rec:
(Where
Available)

Building 2 (South Entrance)

Full Rec Install a panel or replace the door to provide a smooth, Citation CBC 1133B.2.6
uninterrupted surface for the bottom 10 inches of the door.

Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 338
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 86 of 542


Facility Name: San Joaquin Fairgrounds
Doors
Finding: The bottom 10 inches of the door does not provide a smooth,
uninterrupted surface, or panel to allow the door to be opened
by a wheelchair footrest without creating a trap or hazardous
condition, due to the door stop.

Alternative *
Rec:
(Where
Available)

Building 3

Full Rec Install a panel or replace the door to provide a smooth, Citation CBC 1133B.2.6
uninterrupted surface for the bottom 10 inches of the door.

Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 324
Priority:

Doors
Finding: The bottom 10 inches of the exterior doors at Building 4 do not
provide a smooth, uninterrupted surface, or panel to allow the
door to be opened by a wheelchair footrest without creating a
trap or hazardous condition, due to the door stop.

Alternative *
Rec:
(Where
Available)

Building 4

Full Rec Install a panel or replace the door to provide a smooth, Citation CBC 1133B.2.6
uninterrupted surface for the bottom 10 inches of the door.

Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 298
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 87 of 542


Facility Name: San Joaquin Fairgrounds
Doors
Finding: The bottom 10 inches of the exterior doors at Building 5 do not
provide a smooth, uninterrupted surface, or panel to allow the
door to be opened by a wheelchair footrest without creating a
trap or hazardous condition, due to the door stop.

Alternative *
Rec:
(Where
Available)

Building 5

Full Rec Install a panel or replace the door to provide a smooth, Citation CBC 1133B.2.6
uninterrupted surface for the bottom 10 inches of the door.

Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 295
Priority:

Doors
Finding: There is no level landing provided at the entrance door.

Alternative *
Rec:
(Where
Available)

Building 6

Full Rec Provide a level and clear landing at least 60 inches in length in Citation CBC 1133B.2.4.2; ADAAG 4.13.6
the direction of the door swing.

Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 292
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 88 of 542


Facility Name: San Joaquin Fairgrounds
Doors
Finding: There is no level landing provided at the entrance door.

Alternative *
Rec:
(Where
Available)

Building 6 (East Entrance)

Full Rec Provide a level and clear landing at least 60 inches in length in Citation CBC 1133B.2.4.2; ADAAG 4.13.6
the direction of the door swing.

Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 327
Priority:

Doors
Finding: Exterior passage doors have round doorknobs, which require
twisting of the wrist to operate.

Alternative *
Rec:
(Where
Available)

Building 7

Full Rec Replace the existing door hardware with accessible hardware Citation ADAAG 4.13.9
(see ADAAG 4.13.9).

Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 834
Maximum Estimated Cost: 834
Record Number 279
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 89 of 542


Facility Name: San Joaquin Fairgrounds
Doors
Finding: The bottom 10 inches of the door does not provide a smooth,
uninterrupted surface, or panel to allow the door to be opened
by a wheelchair footrest without creating a trap or hazardous
condition, due to the door stop.

Alternative *
Rec:
(Where
Available)

Building 7

Full Rec Install a panel or replace the door to provide a smooth, Citation CBC 1133B.2.6
uninterrupted surface for the bottom 10 inches of the door.

Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 280
Priority:

Doors
Finding: The exterior passage door has a round doorknob, which
requires twisting of the wrist to operate.

Alternative *
Rec:
(Where
Available)

Building 8

Full Rec Replace the existing door hardware with accessible hardware Citation ADAAG 4.13.9
(see ADAAG 4.13.9).

Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 834
Maximum Estimated Cost: 834
Record Number 272
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 90 of 542


Facility Name: San Joaquin Fairgrounds
Doors
Finding: The bottom 10 inches of the door does not provide a smooth,
uninterrupted surface, or panel to allow the door to be opened
by a wheelchair footrest without creating a trap or hazardous
condition, due to the door stop.

Alternative *
Rec:
(Where
Available)

Building 8

Full Rec Install a panel or replace the door to provide a smooth, Citation CBC 1133B.2.6
uninterrupted surface for the bottom 10 inches of the door.

Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 273
Priority:

Doors
Finding: There is less than 12 inches of clearance on the latch side of
the exterior entrance door.

Alternative *
Rec:
(Where
Available)

Building 8

Full Rec Provide at least 12 inches of latch side clearance at the Citation ADAAG 4.13.6
entrance door (see ADAAG 4.13.6 and Figure 25). Otherwise,
install an automatic door opening device.
Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 276
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 91 of 542


Facility Name: San Joaquin Fairgrounds
Doors
Finding: The landing at the entrance door does not provide sufficient
clear floor space.

Alternative *
Rec:
(Where
Available)

Door at L-1

Full Rec Provide a level and clear landing at least 60 inches in length in Citation CBC 1133B.2.4.2; ADAAG 4.13.6
the direction of the door swing.

Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 142
Priority:

Doors
Finding: The exterior passage door has a round doorknob, which
requires twisting of the wrist to operate.

Alternative *
Rec:
(Where
Available)

Exterior Door to the Gym at the Stable Office

Full Rec Replace the existing door hardware with accessible hardware Citation ADAAG 4.13.9
(see ADAAG 4.13.9).

Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 834
Maximum Estimated Cost: 834
Record Number 314
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 92 of 542


Facility Name: San Joaquin Fairgrounds
Doors
Finding: There is no level landing provided at the entrance door.

Alternative *
Rec:
(Where
Available)

Exterior Door to the North West Office

Full Rec Provide a level and clear landing at least 60 inches in length in Citation CBC 1133B.2.4.2; ADAAG 4.13.6
the direction of the door swing.

Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 331
Priority:

Doors
Finding: The height of the threshold at the entrance door is greater than
1/2 inch.

Alternative *
Rec:
(Where
Available)

FFA Office

Full Rec Modify or replace the threshold to provide a smooth transition. Citation CBC 1133B.2.4.1; ADAAG 4.1.6(3)(d)(ii);
The threshold should not exceed a beveled 1/2 inch. Provide a ADAAG 4.5.2
60 inch level landing in the direction of the door swing.
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 2500
Maximum Estimated Cost: 2500
Record Number 290
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 93 of 542


Facility Name: San Joaquin Fairgrounds
Doors
Finding: There is less than 24 inches of clearance on the latch side of
the exterior entrance door.

Alternative *
Rec:
(Where
Available)

Flats BBQ

Full Rec Provide at least 24 inches of latch side clearance at the Citation ADAAG 4.13.6
entrance door (see ADAAG 4.13.6 and Figure 25). Otherwise,
install an automatic door opening device.
Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 319
Priority:

Doors
Finding: There is no level landing provided at the entrance door.

Alternative *
Rec:
(Where
Available)

Grandstands

Full Rec Provide a level and clear landing at least 60 inches in length in Citation CBC 1133B.2.4.2; ADAAG 4.13.6
the direction of the door swing.

Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 322
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 94 of 542


Facility Name: San Joaquin Fairgrounds
Doors
Finding: The bottom 10 inches of the door does not provide a smooth,
uninterrupted surface, or panel to allow the door to be opened
by a wheelchair footrest without creating a trap or hazardous
condition, due to the door stop.

Alternative *
Rec:
(Where
Available)

Grandstands

Full Rec Install a panel or replace the door to provide a smooth, Citation CBC 1133B.2.6
uninterrupted surface for the bottom 10 inches of the door.

Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 323
Priority:

Doors
Finding: The interior passage door to the employee restroom has a
round doorknob, which requires twisting of the wrist to operate.

Alternative *
Rec:
(Where
Available)

Interior Door at the South End of the Grandstands

Full Rec Interior door hardware (doorknobs) should be changed to Citation ADAAG 4.13.9
accessible lever-handled lockset hardware (see ADAAG 4.13.9).

Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 204
Maximum Estimated Cost: 204
Record Number 291
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 95 of 542


Facility Name: San Joaquin Fairgrounds
Doors
Finding: The bottom 10 inches of the door does not provide a smooth,
uninterrupted surface, or panel to allow the door to be opened
by a wheelchair footrest without creating a trap or hazardous
condition, due to the door stop.

Alternative *
Rec:
(Where
Available)

Interior Door in Building 8

Full Rec Install a panel or replace the door to provide a smooth, Citation CBC 1133B.2.6
uninterrupted surface for the bottom 10 inches of the door.

Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 277
Priority:

Doors
Finding: The interior passage door has a round doorknob, which requires
twisting of the wrist to operate.

Alternative *
Rec:
(Where
Available)

Interior Door in Building 8

Full Rec Interior door hardware (doorknobs) should be changed to Citation ADAAG 4.13.9
accessible lever-handled lockset hardware (see ADAAG 4.13.9).

Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 204
Maximum Estimated Cost: 204
Record Number 278
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 96 of 542


Facility Name: San Joaquin Fairgrounds
Doors
Finding: The interior passage door has a round doorknob, which requires
twisting of the wrist to operate.

Alternative *
Rec:
(Where
Available)

Interior Door in L-1

Full Rec Interior door hardware (doorknobs) should be changed to Citation ADAAG 4.13.9
accessible lever-handled lockset hardware (see ADAAG 4.13.9).

Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 204
Maximum Estimated Cost: 204
Record Number 287
Priority:

Doors
Finding: There is less than 18 inches of latch side clearance from the
pull side of the interior entrance door from the restrooms to the
east wing.

Alternative *
Rec:
(Where
Available)

Interior Door in the Stable Office

Full Rec Consult a design professional to determine if it is technically Citation ADAAG 4.13.6; CBC 1133B.2.4.2
feasible to provide at least 18 inches of latch side clearance at
the entrance door from the pull side (see ADAAG 4.13.6 and
Figure 25). Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 318
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 97 of 542


Facility Name: San Joaquin Fairgrounds
Doors
Finding: The bottom 10 inches of the door does not provide a smooth,
uninterrupted surface, or panel to allow the door to be opened
by a wheelchair footrest without creating a trap or hazardous
condition, due to the door stop.

Alternative *
Rec:
(Where
Available)

Interior Door to the Gym in the Stable Office

Full Rec Install a panel or replace the door to provide a smooth, Citation CBC 1133B.2.6
uninterrupted surface for the bottom 10 inches of the door.

Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 312
Priority:

Doors
Finding: There is less than 18 inches of latch side clearance from the
pull side of the interior entrance door.

Alternative *
Rec:
(Where
Available)

Interior Door to the Gym in the Stable Office

Full Rec Consult a design professional to determine if it is technically Citation ADAAG 4.13.6; CBC 1133B.2.4.2
feasible to provide at least 18 inches of latch side clearance at
the entrance door from the pull side (see ADAAG 4.13.6 and
Figure 25). Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 313
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 98 of 542


Facility Name: San Joaquin Fairgrounds
Doors
Finding: The interior passage door has a round doorknob, which requires
twisting of the wrist to operate.

Alternative *
Rec:
(Where
Available)

Interior Door to the Laundry Room in the Jockey's Quarters

Full Rec Interior door hardware (doorknobs) should be changed to Citation ADAAG 4.13.9
accessible lever-handled lockset hardware (see ADAAG 4.13.9).

Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 204
Maximum Estimated Cost: 204
Record Number 328
Priority:

Doors
Finding: The bottom 10 inches of the interior doors in the Jockey's
Quarters does not provide a smooth, uninterrupted surface, or
panel to allow the door to be opened by a wheelchair footrest
without creating a trap or hazardous condition.

Alternative *
Rec:
(Where
Available)

Jockey's Quarters

Full Rec Install a panel or replace the door to provide a smooth, Citation CBC 1133B.2.6
uninterrupted surface for the bottom 10 inches of the door.

Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 299
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 99 of 542


Facility Name: San Joaquin Fairgrounds
Doors
Finding: The exterior door is set in an alcove. There is less than 24
inches of clearance on the latch side of the exterior entrance
door.

Alternative Install an automatic door opening device to the primary


Rec: entrance complying with ADAAG 4.13.12 and ANSI/BHMA
(Where A156.10, 1985, standards.
Available)

Jockey's Quarters

Full Rec Povide at least 24 inches between the latch side of the door and Citation ADAAG 4.13.6
the side wall of the alcove at the primary entrance. Otherwise
install a compliant automatic door opening device.
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1921
Maximum Estimated Cost: 0
Record Number 329
Priority:

Doors
Finding: The exterior passage door has a round doorknob, which
requires twisting of the wrist to operate.

Alternative *
Rec:
(Where
Available)

Jockey's Quarters (North Entrance)

Full Rec Replace the existing door hardware with accessible hardware Citation ADAAG 4.13.9
(see ADAAG 4.13.9).

Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 834
Maximum Estimated Cost: 834
Record Number 300
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 100 of 542


Facility Name: San Joaquin Fairgrounds
Doors
Finding: There is less than 24 inches of clearance on the latch side of
the exterior entrance door.

Alternative *
Rec:
(Where
Available)

Jockey's Quarters (North Entrance)

Full Rec Provide at least 24 inches of latch side clearance at the Citation ADAAG 4.13.6
entrance door (see ADAAG 4.13.6 and Figure 25). Otherwise,
install an automatic door opening device.
Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 303
Priority:

Doors
Finding: The interior passage door has a round doorknob, which requires
twisting of the wrist to operate.

Alternative *
Rec:
(Where
Available)

Livestock Office

Full Rec Interior door hardware (doorknobs) should be changed to Citation ADAAG 4.13.9
accessible lever-handled lockset hardware (see ADAAG 4.13.9).

Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 204
Maximum Estimated Cost: 204
Record Number 288
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 101 of 542


Facility Name: San Joaquin Fairgrounds
Doors
Finding: The bottom 10 inches of the door does not provide a smooth,
uninterrupted surface, or panel to allow the door to be opened
by a wheelchair footrest without creating a trap or hazardous
condition, due to the door stop.

Alternative *
Rec:
(Where
Available)

Livestock Office

Full Rec Install a panel or replace the door to provide a smooth, Citation CBC 1133B.2.6
uninterrupted surface for the bottom 10 inches of the door.

Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 289
Priority:

Doors
Finding: The bottom 10 inches of the door does not provide a smooth,
uninterrupted surface, or panel to allow the door to be opened
by a wheelchair footrest without creating a trap or hazardous
condition, due to the door stop.

Alternative *
Rec:
(Where
Available)

Main Office (South Entrance)

Full Rec Install a panel or replace the door to provide a smooth, Citation CBC 1133B.2.6
uninterrupted surface for the bottom 10 inches of the door.

Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 321
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 102 of 542


Facility Name: San Joaquin Fairgrounds
Doors
Finding: Interior passage doors have round doorknobs, which require
twisting of the wrist to operate.

Alternative *
Rec:
(Where
Available)

Maintenance Office

Full Rec Interior door hardware (doorknobs) should be changed to Citation ADAAG 4.13.9
accessible lever-handled lockset hardware (see ADAAG 4.13.9).

Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 204
Maximum Estimated Cost: 204
Record Number 330
Priority:

Doors
Finding: Exterior passage doors at each entrance to the Stable Office
have round doorknobs, which require twisting of the wrist to
operate.

Alternative *
Rec:
(Where
Available)

Stable Office

Full Rec Replace the existing door hardware with accessible hardware Citation ADAAG 4.13.9
(see ADAAG 4.13.9).

Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 834
Maximum Estimated Cost: 834
Record Number 306
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 103 of 542


Facility Name: San Joaquin Fairgrounds
Doors
Finding: The bottom 10 inches of the door does not provide a smooth,
uninterrupted surface, or panel to allow the door to be opened
by a wheelchair footrest without creating a trap or hazardous
condition, due to the door stop.

Alternative *
Rec:
(Where
Available)

Stable Office

Full Rec Install a panel or replace the door to provide a smooth, Citation CBC 1133B.2.6
uninterrupted surface for the bottom 10 inches of the door.

Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 307
Priority:

Doors
Finding: The height of the threshold at the entrance door is greater than
1/2 inch.

Alternative *
Rec:
(Where
Available)

Stable Office

Full Rec Modify or replace the threshold to provide a smooth transition. Citation CBC 1133B.2.4.1; ADAAG 4.1.6(3)(d)(ii);
The threshold should not exceed a beveled 1/2 inch. Provide a ADAAG 4.5.2
60 inch level landing in the direction of the door swing.
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 2500
Maximum Estimated Cost: 2500
Record Number 310
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 104 of 542


Facility Name: San Joaquin Fairgrounds
Doors
Finding: Interior passage doors have round doorknobs, which require
twisting of the wrist to operate.

Alternative *
Rec:
(Where
Available)

Stable Office

Full Rec Interior door hardware (doorknobs) should be changed to Citation ADAAG 4.13.9
accessible lever-handled lockset hardware (see ADAAG 4.13.9).

Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 204
Maximum Estimated Cost: 204
Record Number 311
Priority:

Doors
Finding: The bottom 10 inches of the door does not provide a smooth,
uninterrupted surface, or panel to allow the door to be opened
by a wheelchair footrest without creating a trap or hazardous
condition, due to the doorstop.

Alternative *
Rec:
(Where
Available)

Stable Office (East Entrance)

Full Rec Install a panel or replace the door to provide a smooth, Citation CBC 1133B.2.6
uninterrupted surface for the bottom 10 inches of the door.

Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 317
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 105 of 542


Facility Name: San Joaquin Fairgrounds
Doors
Finding: Exterior passage doors have round doorknobs, which require
twisting of the wrist to operate.

Alternative *
Rec:
(Where
Available)

Stable Office (West Entrance)

Full Rec Replace the existing door hardware with accessible hardware Citation ADAAG 4.13.9
(see ADAAG 4.13.9).

Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 834
Maximum Estimated Cost: 834
Record Number 315
Priority:

Doors
Finding: The landing at the entrance door does not provide sufficient
clear floor space.

Alternative *
Rec:
(Where
Available)

Stable Office (West Entrance)

Full Rec Provide a level and clear landing at least 60 inches in length in Citation CBC 1133B.2.4.2; ADAAG 4.13.6
the direction of the door swing.

Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 316
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 106 of 542


Facility Name: San Joaquin Fairgrounds
Doors
Finding: The bottom 10 inches of the door does not provide a smooth,
uninterrupted surface, or panel to allow the door to be opened
by a wheelchair footrest without creating a trap or hazardous
condition, due to the door stop.

Alternative *
Rec:
(Where
Available)

Winners Gaming and Sports Emporium

Full Rec Install a panel or replace the door to provide a smooth, Citation CBC 1133B.2.6
uninterrupted surface for the bottom 10 inches of the door.

Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 320
Priority:

Counters
Finding: The height of the Administration Office reception counter is
greater than 34 inches.

Alternative *
Rec:
(Where
Available)

Administration Office

Full Rec Lower at least a 36 inch wide portion of the Administration Office Citation CBC 1122B.4; ADAAG 7.2
reception counter to a maximum height between 28 and 34
inches (see CBC 1122B.4).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 348
Maximum Estimated Cost: 348
Record Number 339
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 107 of 542


Facility Name: San Joaquin Fairgrounds
Counters
Finding: The height of the Building 3 reception counter is greater than 34
inches.

Alternative *
Rec:
(Where
Available)

Building 3

Full Rec Lower at least a 36 inch wide portion of the reception counter to Citation CBC 1122B.4; ADAAG 7.2
a maximum height between 28 and 34 inches (see CBC
1122B.4).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 348
Maximum Estimated Cost: 348
Record Number 343
Priority:

Counters
Finding: The height of the Building 7 reception counter is greater than 34
inches.

Alternative *
Rec:
(Where
Available)

Building 7

Full Rec Lower at least a 36 inch wide portion of the reception counter to Citation CBC 1122B.4; ADAAG 7.2
a maximum height between 28 and 34 inches (see CBC
1122B.4).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 348
Maximum Estimated Cost: 348
Record Number 357
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 108 of 542


Facility Name: San Joaquin Fairgrounds
Counters
Finding: The height of the counter at the scale shop is greater than 34
inches.

Alternative *
Rec:
(Where
Available)

Delta Speedway

Full Rec Lower at least a 36 inch wide portion of the counter to a Citation CBC 1122B.4; ADAAG 7.2
maximum height between 28 and 34 inches (see CBC 1122B.4).

Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 348
Maximum Estimated Cost: 348
Record Number 341
Priority:

Counters
Finding: The height of the Fitness Center reception counter is greater
than 34 inches.

Alternative *
Rec:
(Where
Available)

Fitness Center (West Entrance)

Full Rec Lower at least a 36 inch wide portion of the reception counter to Citation CBC 1122B.4; ADAAG 7.2
a maximum height between 28 and 34 inches (see CBC
1122B.4).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 348
Maximum Estimated Cost: 348
Record Number 361
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 109 of 542


Facility Name: San Joaquin Fairgrounds
Counters
Finding: The height of the Fitness Center reception counter is greater
than 34 inches.

Alternative *
Rec:
(Where
Available)

Fitness Center in the Stable Office

Full Rec Lower at least a 36 inch wide portion of the reception counter to Citation CBC 1122B.4; ADAAG 7.2
a maximum height between 28 and 34 inches (see CBC
1122B.4).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 348
Maximum Estimated Cost: 348
Record Number 349
Priority:

Counters
Finding: The height of the betting counter at the south end of the
Grandstands is greater than 34 inches.

Alternative *
Rec:
(Where
Available)

Grandstands

Full Rec Lower at least a 36 inch wide portion of the counter to a Citation CBC 1122B.4; ADAAG 7.2
maximum height between 28 and 34 inches (see CBC 1122B.4).

Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 348
Maximum Estimated Cost: 348
Record Number 359
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 110 of 542


Facility Name: San Joaquin Fairgrounds
Counters
Finding: The height of the betting counters is greater than 34 inches.

Alternative *
Rec:
(Where
Available)

Grandstands

Full Rec Lower at least a 36 inch wide portion of the counters to a Citation CBC 1122B.4; ADAAG 7.2
maximum height between 28 and 34 inches (see CBC 1122B.4).

Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 348
Maximum Estimated Cost: 348
Record Number 362
Priority:

Counters
Finding: The height of the reception counter in L-1 is greater than 34
inches.

Alternative *
Rec:
(Where
Available)

L-1

Full Rec Lower at least a 36 inch wide portion of the reception counter to Citation CBC 1122B.4; ADAAG 7.2
a maximum height between 28 and 34 inches (see CBC
1122B.4).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 348
Maximum Estimated Cost: 348
Record Number 354
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 111 of 542


Facility Name: San Joaquin Fairgrounds
Counters
Finding: The height of the exterior counter is greater than 34 inches.

Alternative *
Rec:
(Where
Available)

Livestock Office

Full Rec Lower at least a 36 inch wide portion of the counter to a Citation CBC 1122B.4; ADAAG 7.2
maximum height between 28 and 34 inches (see CBC 1122B.4).

Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 348
Maximum Estimated Cost: 348
Record Number 344
Priority:

Counters
Finding: The height of the Security Office reception counter is greater
than 34 inches.

Alternative *
Rec:
(Where
Available)

Security Office

Full Rec Lower at least a 36 inch wide portion of the reception counter to Citation CBC 1122B.4; ADAAG 7.2
a maximum height between 28 and 34 inches (see CBC
1122B.4).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 348
Maximum Estimated Cost: 348
Record Number 356
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 112 of 542


Facility Name: San Joaquin Fairgrounds
Counters
Finding: The height of the reception counter at the east entrance to the
Stable Office is greater than 34 inches.

Alternative *
Rec:
(Where
Available)

Stable Office

Full Rec Lower at least a 36 inch wide portion of the sales counter to a Citation CBC 1122B.4; ADAAG 7.2
maximum height between 28 and 34 inches (see CBC 1122B.4).

Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 348
Maximum Estimated Cost: 348
Record Number 348
Priority:

Counters
Finding: The height of the Stable Office reception counter is greater than
34 inches.

Alternative *
Rec:
(Where
Available)

Stable Office

Full Rec Lower at least a 36 inch wide portion of the reception counter to Citation CBC 1122B.4; ADAAG 7.2
a maximum height between 28 and 34 inches (see CBC
1122B.4).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 348
Maximum Estimated Cost: 348
Record Number 350
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 113 of 542


Facility Name: San Joaquin Fairgrounds
Counters
Finding: The height of the ticket counters at the main entrance to the
Fairgrounds is greater than 36 inches.

Alternative *
Rec:
(Where
Available)

Ticket Counters at the Main Entrance

Full Rec Lower one of the ticket counters to a height no greater than 36 Citation ADAAG 7.2
inches above the ground (see ADAAG 7.2).

Minimum Quantity 1
Maximum Quantity: 1
Unit: 3 Linear Feet
Minimum Estimated Cost: 129
Maximum Estimated Cost: 129
Record Number 190
Priority:

Counters
Finding: The height of the change counter is greater than 34 inches.

Alternative *
Rec:
(Where
Available)

Winners Gaming and Sports Emporium

Full Rec Lower at least a 36 inch wide portion of the change counter to a Citation CBC 1122B.4; ADAAG 7.2
maximum height between 28 and 34 inches (see CBC 1122B.4).

Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 348
Maximum Estimated Cost: 348
Record Number 340
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 114 of 542


Facility Name: San Joaquin Fairgrounds
Counters
Finding: The height of the Champions counters is greater than 34 inches.

Alternative *
Rec:
(Where
Available)

Winners Gaming and Sports Emporium

Full Rec Lower at least a 36 inch wide portion of the counter to a Citation CBC 1122B.4; ADAAG 7.2
maximum height between 28 and 34 inches (see CBC 1122B.4).

Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 348
Maximum Estimated Cost: 348
Record Number 345
Priority:

Visual and Audible Communications


Finding: There is no signage with the International Symbol of
Accessibility on the entrance door to the facility designating it as
accessible.

Alternative *
Rec:
(Where
Available)

Administration Office

Full Rec The International Symbol of Accessibility shall be the standard Citation CBC 1117B.5.1
used to identify facilities that are accessible to and usable by
physically disabled persons (see CBC 1117B.5.1). All building
entrances that are accessible to and usable by persons with Minimum Quantity 1
disabilities shall be identified with an ISA symbol (see CBC Maximum Quantity: 1
1117B.5.7).
Unit: Each
Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 366
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 115 of 542


Facility Name: San Joaquin Fairgrounds
Visual and Audible Communications
Finding: The main entrance does not have accessible signage mounted
on the wall adjacent to the latch side of the door.

Alternative *
Rec:
(Where
Available)

Administration Office

Full Rec Install signage centered at 60 inches above the finished floor on Citation CBC 1117B.5; ADAAG 4.30
the wall adjacent to the latch side of the entry doorway stating
ENTRANCE from the outside and EXIT from the inside, with
raised UPPERCASE letters between 5/8 inch and 2 inches in Minimum Quantity 1
height and Grade 2 Braille characters. The sign shall comply Maximum Quantity: 1
with the finish and contrast requirements set forth in CBC
1117B.5 and ADAAG 4.30.5. Signage should be located where Unit: Each
a person may approach within three inches of the sign without Minimum Estimated Cost: 58
encountering protruding objects or standing within the swing of
the door. Maximum Estimated Cost: 58
Record Number 367
Priority:

Visual and Audible Communications


Finding: There is no signage with the International Symbol of
Accessibility on the entrance door to the facility designating it as
accessible.

Alternative *
Rec:
(Where
Available)

Building 1

Full Rec The International Symbol of Accessibility shall be the standard Citation CBC 1117B.5.1
used to identify facilities that are accessible to and usable by
physically disabled persons (see CBC 1117B.5.1). All building
entrances that are accessible to and usable by persons with Minimum Quantity 1
disabilities shall be identified with an ISA symbol (see CBC Maximum Quantity: 1
1117B.5.7).
Unit: Each
Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 334
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 116 of 542


Facility Name: San Joaquin Fairgrounds
Visual and Audible Communications
Finding: The main entrance does not have accessible signage mounted
on the wall adjacent to the latch side of the door.

Alternative *
Rec:
(Where
Available)

Building 1

Full Rec Install signage centered at 60 inches above the finished floor on Citation CBC 1117B.5; ADAAG 4.30
the wall adjacent to the latch side of the entry doorway stating
ENTRANCE from the outside and EXIT from the inside, with
raised UPPERCASE letters between 5/8 inch and 2 inches in Minimum Quantity 1
height and Grade 2 Braille characters. The sign shall comply Maximum Quantity: 1
with the finish and contrast requirements set forth in CBC
1117B.5 and ADAAG 4.30.5. Signage should be located where Unit: Each
a person may approach within three inches of the sign without Minimum Estimated Cost: 58
encountering protruding objects or standing within the swing of
the door. Maximum Estimated Cost: 58
Record Number 335
Priority:

Visual and Audible Communications


Finding: There is no signage with the International Symbol of
Accessibility on the entrance door to the facility designating it as
accessible.

Alternative *
Rec:
(Where
Available)

Building 2

Full Rec The International Symbol of Accessibility shall be the standard Citation CBC 1117B.5.1
used to identify facilities that are accessible to and usable by
physically disabled persons (see CBC 1117B.5.1). All building
entrances that are accessible to and usable by persons with Minimum Quantity 1
disabilities shall be identified with an ISA symbol (see CBC Maximum Quantity: 1
1117B.5.7).
Unit: Each
Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 283
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 117 of 542


Facility Name: San Joaquin Fairgrounds
Visual and Audible Communications
Finding: The main entrance does not have accessible signage mounted
on the wall adjacent to the latch side of the door.

Alternative *
Rec:
(Where
Available)

Building 2

Full Rec Install signage centered at 60 inches above the finished floor on Citation CBC 1117B.5; ADAAG 4.30
the wall adjacent to the latch side of the entry doorway stating
ENTRANCE from the outside and EXIT from the inside, with
raised UPPERCASE letters between 5/8 inch and 2 inches in Minimum Quantity 1
height and Grade 2 Braille characters. The sign shall comply Maximum Quantity: 1
with the finish and contrast requirements set forth in CBC
1117B.5 and ADAAG 4.30.5. Signage should be located where Unit: Each
a person may approach within three inches of the sign without Minimum Estimated Cost: 58
encountering protruding objects or standing within the swing of
the door. Maximum Estimated Cost: 58
Record Number 284
Priority:

Visual and Audible Communications


Finding: There is no signage with the International Symbol of
Accessibility on the entrance door to the facility designating it as
accessible.

Alternative *
Rec:
(Where
Available)

Building 3

Full Rec The International Symbol of Accessibility shall be the standard Citation CBC 1117B.5.1
used to identify facilities that are accessible to and usable by
physically disabled persons (see CBC 1117B.5.1). All building
entrances that are accessible to and usable by persons with Minimum Quantity 1
disabilities shall be identified with an ISA symbol (see CBC Maximum Quantity: 1
1117B.5.7).
Unit: Each
Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 325
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 118 of 542


Facility Name: San Joaquin Fairgrounds
Visual and Audible Communications
Finding: The main entrance does not have accessible signage mounted
on the wall adjacent to the latch side of the door.

Alternative *
Rec:
(Where
Available)

Building 3

Full Rec Install signage centered at 60 inches above the finished floor on Citation CBC 1117B.5; ADAAG 4.30
the wall adjacent to the latch side of the entry doorway stating
ENTRANCE from the outside and EXIT from the inside, with
raised UPPERCASE letters between 5/8 inch and 2 inches in Minimum Quantity 1
height and Grade 2 Braille characters. The sign shall comply Maximum Quantity: 1
with the finish and contrast requirements set forth in CBC
1117B.5 and ADAAG 4.30.5. Signage should be located where Unit: Each
a person may approach within three inches of the sign without Minimum Estimated Cost: 58
encountering protruding objects or standing within the swing of
the door. Maximum Estimated Cost: 58
Record Number 326
Priority:

Visual and Audible Communications


Finding: There is no signage with the International Symbol of
Accessibility on the entrance door to the facility designating it as
accessible.

Alternative *
Rec:
(Where
Available)

Building 4

Full Rec The International Symbol of Accessibility shall be the standard Citation CBC 1117B.5.1
used to identify facilities that are accessible to and usable by
physically disabled persons (see CBC 1117B.5.1). All building
entrances that are accessible to and usable by persons with Minimum Quantity 1
disabilities shall be identified with an ISA symbol (see CBC Maximum Quantity: 1
1117B.5.7).
Unit: Each
Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 370
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 119 of 542


Facility Name: San Joaquin Fairgrounds
Visual and Audible Communications
Finding: The main entrance does not have accessible signage mounted
on the wall adjacent to the latch side of the door.

Alternative *
Rec:
(Where
Available)

Building 4

Full Rec Install signage centered at 60 inches above the finished floor on Citation CBC 1117B.5; ADAAG 4.30
the wall adjacent to the latch side of the entry doorway stating
ENTRANCE from the outside and EXIT from the inside, with
raised UPPERCASE letters between 5/8 inch and 2 inches in Minimum Quantity 1
height and Grade 2 Braille characters. The sign shall comply Maximum Quantity: 1
with the finish and contrast requirements set forth in CBC
1117B.5 and ADAAG 4.30.5. Signage should be located where Unit: Each
a person may approach within three inches of the sign without Minimum Estimated Cost: 58
encountering protruding objects or standing within the swing of
the door. Maximum Estimated Cost: 58
Record Number 371
Priority:

Visual and Audible Communications


Finding: There is no signage with the International Symbol of
Accessibility on the entrance door to the facility designating it as
accessible.

Alternative *
Rec:
(Where
Available)

Building 5

Full Rec The International Symbol of Accessibility shall be the standard Citation CBC 1117B.5.1
used to identify facilities that are accessible to and usable by
physically disabled persons (see CBC 1117B.5.1). All building
entrances that are accessible to and usable by persons with Minimum Quantity 1
disabilities shall be identified with an ISA symbol (see CBC Maximum Quantity: 1
1117B.5.7).
Unit: Each
Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 216
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 120 of 542


Facility Name: San Joaquin Fairgrounds
Visual and Audible Communications
Finding: The main entrance does not have accessible signage mounted
on the wall adjacent to the latch side of the door.

Alternative *
Rec:
(Where
Available)

Building 5

Full Rec Install signage centered at 60 inches above the finished floor on Citation CBC 1117B.5; ADAAG 4.30
the wall adjacent to the latch side of the entry doorway stating
ENTRANCE from the outside and EXIT from the inside, with
raised UPPERCASE letters between 5/8 inch and 2 inches in Minimum Quantity 1
height and Grade 2 Braille characters. The sign shall comply Maximum Quantity: 1
with the finish and contrast requirements set forth in CBC
1117B.5 and ADAAG 4.30.5. Signage should be located where Unit: Each
a person may approach within three inches of the sign without Minimum Estimated Cost: 58
encountering protruding objects or standing within the swing of
the door. Maximum Estimated Cost: 58
Record Number 217
Priority:

Visual and Audible Communications


Finding: There is no signage with the International Symbol of
Accessibility on the entrance door to the facility designating it as
accessible.

Alternative *
Rec:
(Where
Available)

Building 6

Full Rec The International Symbol of Accessibility shall be the standard Citation CBC 1117B.5.1
used to identify facilities that are accessible to and usable by
physically disabled persons (see CBC 1117B.5.1). All building
entrances that are accessible to and usable by persons with Minimum Quantity 1
disabilities shall be identified with an ISA symbol (see CBC Maximum Quantity: 1
1117B.5.7).
Unit: Each
Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 293
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 121 of 542


Facility Name: San Joaquin Fairgrounds
Visual and Audible Communications
Finding: The main entrance does not have accessible signage mounted
on the wall adjacent to the latch side of the door.

Alternative *
Rec:
(Where
Available)

Building 6

Full Rec Install signage centered at 60 inches above the finished floor on Citation CBC 1117B.5; ADAAG 4.30
the wall adjacent to the latch side of the entry doorway stating
ENTRANCE from the outside and EXIT from the inside, with
raised UPPERCASE letters between 5/8 inch and 2 inches in Minimum Quantity 1
height and Grade 2 Braille characters. The sign shall comply Maximum Quantity: 1
with the finish and contrast requirements set forth in CBC
1117B.5 and ADAAG 4.30.5. Signage should be located where Unit: Each
a person may approach within three inches of the sign without Minimum Estimated Cost: 58
encountering protruding objects or standing within the swing of
the door. Maximum Estimated Cost: 58
Record Number 294
Priority:

Visual and Audible Communications


Finding: There is no signage with the International Symbol of
Accessibility on the entrance door to the facility designating it as
accessible.

Alternative *
Rec:
(Where
Available)

Building 7

Full Rec The International Symbol of Accessibility shall be the standard Citation CBC 1117B.5.1
used to identify facilities that are accessible to and usable by
physically disabled persons (see CBC 1117B.5.1). All building
entrances that are accessible to and usable by persons with Minimum Quantity 1
disabilities shall be identified with an ISA symbol (see CBC Maximum Quantity: 1
1117B.5.7).
Unit: Each
Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 281
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 122 of 542


Facility Name: San Joaquin Fairgrounds
Visual and Audible Communications
Finding: The main entrance does not have accessible signage mounted
on the wall adjacent to the latch side of the door.

Alternative *
Rec:
(Where
Available)

Building 7

Full Rec Install signage centered at 60 inches above the finished floor on Citation CBC 1117B.5; ADAAG 4.30
the wall adjacent to the latch side of the entry doorway stating
ENTRANCE from the outside and EXIT from the inside, with
raised UPPERCASE letters between 5/8 inch and 2 inches in Minimum Quantity 1
height and Grade 2 Braille characters. The sign shall comply Maximum Quantity: 1
with the finish and contrast requirements set forth in CBC
1117B.5 and ADAAG 4.30.5. Signage should be located where Unit: Each
a person may approach within three inches of the sign without Minimum Estimated Cost: 58
encountering protruding objects or standing within the swing of
the door. Maximum Estimated Cost: 58
Record Number 282
Priority:

Visual and Audible Communications


Finding: There is no signage with the International Symbol of
Accessibility on the entrance door to the facility designating it as
accessible.

Alternative *
Rec:
(Where
Available)

Building 8

Full Rec The International Symbol of Accessibility shall be the standard Citation CBC 1117B.5.1
used to identify facilities that are accessible to and usable by
physically disabled persons (see CBC 1117B.5.1). All building
entrances that are accessible to and usable by persons with Minimum Quantity 1
disabilities shall be identified with an ISA symbol (see CBC Maximum Quantity: 1
1117B.5.7).
Unit: Each
Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 274
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 123 of 542


Facility Name: San Joaquin Fairgrounds
Visual and Audible Communications
Finding: The main entrance does not have accessible signage mounted
on the wall adjacent to the latch side of the door.

Alternative *
Rec:
(Where
Available)

Building 8

Full Rec Install signage centered at 60 inches above the finished floor on Citation CBC 1117B.5; ADAAG 4.30
the wall adjacent to the latch side of the entry doorway stating
ENTRANCE from the outside and EXIT from the inside, with
raised UPPERCASE letters between 5/8 inch and 2 inches in Minimum Quantity 1
height and Grade 2 Braille characters. The sign shall comply Maximum Quantity: 1
with the finish and contrast requirements set forth in CBC
1117B.5 and ADAAG 4.30.5. Signage should be located where Unit: Each
a person may approach within three inches of the sign without Minimum Estimated Cost: 58
encountering protruding objects or standing within the swing of
the door. Maximum Estimated Cost: 58
Record Number 275
Priority:

Visual and Audible Communications


Finding: There is no directional signage to the accessible entrance from
the public right of way or other common use areas.

Alternative *
Rec:
(Where
Available)

Directional Signage

Full Rec Install directional signage to each common area complying with Citation CBC 1117B.5; ADAAG 4.30
CBC 1117B.5 and ADAAG 4.30.

Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 379
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 124 of 542


Facility Name: San Joaquin Fairgrounds
Visual and Audible Communications
Finding: There is no signage with the International Symbol of
Accessibility on the entrance door to the facility designating it as
accessible.

Alternative *
Rec:
(Where
Available)

FFA

Full Rec The International Symbol of Accessibility shall be the standard Citation CBC 1117B.5.1
used to identify facilities that are accessible to and usable by
physically disabled persons (see CBC 1117B.5.1). All building
entrances that are accessible to and usable by persons with Minimum Quantity 1
disabilities shall be identified with an ISA symbol (see CBC Maximum Quantity: 1
1117B.5.7).
Unit: Each
Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 368
Priority:

Visual and Audible Communications


Finding: The main entrance does not have accessible signage mounted
on the wall adjacent to the latch side of the door.

Alternative *
Rec:
(Where
Available)

FFA

Full Rec Install signage centered at 60 inches above the finished floor on Citation CBC 1117B.5; ADAAG 4.30
the wall adjacent to the latch side of the entry doorway stating
ENTRANCE from the outside and EXIT from the inside, with
raised UPPERCASE letters between 5/8 inch and 2 inches in Minimum Quantity 1
height and Grade 2 Braille characters. The sign shall comply Maximum Quantity: 1
with the finish and contrast requirements set forth in CBC
1117B.5 and ADAAG 4.30.5. Signage should be located where Unit: Each
a person may approach within three inches of the sign without Minimum Estimated Cost: 58
encountering protruding objects or standing within the swing of
the door. Maximum Estimated Cost: 58
Record Number 369
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 125 of 542


Facility Name: San Joaquin Fairgrounds
Visual and Audible Communications
Finding: There is no signage with the International Symbol of
Accessibility on the entrance door to the facility designating it as
accessible.

Alternative *
Rec:
(Where
Available)

Flats BBQ

Full Rec The International Symbol of Accessibility shall be the standard Citation CBC 1117B.5.1
used to identify facilities that are accessible to and usable by
physically disabled persons (see CBC 1117B.5.1). All building
entrances that are accessible to and usable by persons with Minimum Quantity 1
disabilities shall be identified with an ISA symbol (see CBC Maximum Quantity: 1
1117B.5.7).
Unit: Each
Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 374
Priority:

Visual and Audible Communications


Finding: The main entrance does not have accessible signage mounted
on the wall adjacent to the latch side of the door.

Alternative *
Rec:
(Where
Available)

Flats BBQ

Full Rec Install signage centered at 60 inches above the finished floor on Citation CBC 1117B.5; ADAAG 4.30
the wall adjacent to the latch side of the entry doorway stating
ENTRANCE from the outside and EXIT from the inside, with
raised UPPERCASE letters between 5/8 inch and 2 inches in Minimum Quantity 1
height and Grade 2 Braille characters. The sign shall comply Maximum Quantity: 1
with the finish and contrast requirements set forth in CBC
1117B.5 and ADAAG 4.30.5. Signage should be located where Unit: Each
a person may approach within three inches of the sign without Minimum Estimated Cost: 58
encountering protruding objects or standing within the swing of
the door. Maximum Estimated Cost: 58
Record Number 375
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 126 of 542


Facility Name: San Joaquin Fairgrounds
Visual and Audible Communications
Finding: There is no signage with the International Symbol of
Accessibility on the entrance door to the facility designating it as
accessible.

Alternative *
Rec:
(Where
Available)

Jockey's Quarters

Full Rec The International Symbol of Accessibility shall be the standard Citation CBC 1117B.5.1
used to identify facilities that are accessible to and usable by
physically disabled persons (see CBC 1117B.5.1). All building
entrances that are accessible to and usable by persons with Minimum Quantity 1
disabilities shall be identified with an ISA symbol (see CBC Maximum Quantity: 1
1117B.5.7).
Unit: Each
Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 301
Priority:

Visual and Audible Communications


Finding: The main entrance does not have accessible signage mounted
on the wall adjacent to the latch side of the door.

Alternative *
Rec:
(Where
Available)

Jockey's Quarters

Full Rec Install signage centered at 60 inches above the finished floor on Citation CBC 1117B.5; ADAAG 4.30
the wall adjacent to the latch side of the entry doorway stating
ENTRANCE from the outside and EXIT from the inside, with
raised UPPERCASE letters between 5/8 inch and 2 inches in Minimum Quantity 1
height and Grade 2 Braille characters. The sign shall comply Maximum Quantity: 1
with the finish and contrast requirements set forth in CBC
1117B.5 and ADAAG 4.30.5. Signage should be located where Unit: Each
a person may approach within three inches of the sign without Minimum Estimated Cost: 58
encountering protruding objects or standing within the swing of
the door. Maximum Estimated Cost: 58
Record Number 302
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 127 of 542


Facility Name: San Joaquin Fairgrounds
Visual and Audible Communications
Finding: There is no signage with the International Symbol of
Accessibility on the entrance door to the facility designating it as
accessible.

Alternative *
Rec:
(Where
Available)

Linden Lions Building

Full Rec The International Symbol of Accessibility shall be the standard Citation CBC 1117B.5.1
used to identify facilities that are accessible to and usable by
physically disabled persons (see CBC 1117B.5.1). All building
entrances that are accessible to and usable by persons with Minimum Quantity 1
disabilities shall be identified with an ISA symbol (see CBC Maximum Quantity: 1
1117B.5.7).
Unit: Each
Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 372
Priority:

Visual and Audible Communications


Finding: The main entrance does not have accessible signage mounted
on the wall adjacent to the latch side of the door.

Alternative *
Rec:
(Where
Available)

Linden Lions Building

Full Rec Install signage centered at 60 inches above the finished floor on Citation CBC 1117B.5; ADAAG 4.30
the wall adjacent to the latch side of the entry doorway stating
ENTRANCE from the outside and EXIT from the inside, with
raised UPPERCASE letters between 5/8 inch and 2 inches in Minimum Quantity 1
height and Grade 2 Braille characters. The sign shall comply Maximum Quantity: 1
with the finish and contrast requirements set forth in CBC
1117B.5 and ADAAG 4.30.5. Signage should be located where Unit: Each
a person may approach within three inches of the sign without Minimum Estimated Cost: 58
encountering protruding objects or standing within the swing of
the door. Maximum Estimated Cost: 58
Record Number 373
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 128 of 542


Facility Name: San Joaquin Fairgrounds
Visual and Audible Communications
Finding: There is no signage with the International Symbol of
Accessibility on the entrance door to the facility designating it as
accessible.

Alternative *
Rec:
(Where
Available)

Main Office

Full Rec The International Symbol of Accessibility shall be the standard Citation CBC 1117B.5.1
used to identify facilities that are accessible to and usable by
physically disabled persons (see CBC 1117B.5.1). All building
entrances that are accessible to and usable by persons with Minimum Quantity 1
disabilities shall be identified with an ISA symbol (see CBC Maximum Quantity: 1
1117B.5.7).
Unit: Each
Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 376
Priority:

Visual and Audible Communications


Finding: The main entrance does not have accessible signage mounted
on the wall adjacent to the latch side of the door.

Alternative *
Rec:
(Where
Available)

Main Office

Full Rec Install signage centered at 60 inches above the finished floor on Citation CBC 1117B.5; ADAAG 4.30
the wall adjacent to the latch side of the entry doorway stating
ENTRANCE from the outside and EXIT from the inside, with
raised UPPERCASE letters between 5/8 inch and 2 inches in Minimum Quantity 1
height and Grade 2 Braille characters. The sign shall comply Maximum Quantity: 1
with the finish and contrast requirements set forth in CBC
1117B.5 and ADAAG 4.30.5. Signage should be located where Unit: Each
a person may approach within three inches of the sign without Minimum Estimated Cost: 58
encountering protruding objects or standing within the swing of
the door. Maximum Estimated Cost: 58
Record Number 377
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 129 of 542


Facility Name: San Joaquin Fairgrounds
Visual and Audible Communications
Finding: There are four pay telephones at the facility, located in the
Winners Gaming and Sports Emporium, outside of the men's
restroom next to the Livestock area, next to the Stable Office
and at the west entrance of Building 2.

Alternative *
Rec:
(Where
Available)

Pay Telephone

Full Rec Contact the telephone company that owns the pay telephone Citation CBC 1117B.2.1; ADAAG 4.31
regarding following items that do not comply with ADA
requirements. The telephone company is responsible for ADA
compliance, if the facility has no ownership in the pay telephone. Minimum Quantity 1
Maximum Quantity: 1
Unit: None Selected
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 363
Priority:

Visual and Audible Communications


Finding: There is no electrical outlet within or adjacent to the telephone
enclosure.

Alternative *
Rec:
(Where
Available)

Pay Telephone at the West Entrance to Building 2

Full Rec Electrical outlets within or adjacent to the telephone enclosure Citation CBC 1117B.2.9; ADAAG 4.31
are required at pay telephones designed to accommodate a
portable text telephone.
Minimum Quantity 1
Maximum Quantity: 1
Unit: None Selected
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 365
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 130 of 542


Facility Name: San Joaquin Fairgrounds
Visual and Audible Communications
Finding: There is no electrical outlet within or adjacent to the telephone
enclosure.

Alternative *
Rec:
(Where
Available)

Pay Telephone Outside of the Men's Restroom at the


Livestock Area

Full Rec Electrical outlets within or adjacent to the telephone enclosure Citation CBC 1117B.2.9; ADAAG 4.31
are required at pay telephones designed to accommodate a
portable text telephone.
Minimum Quantity 1
Maximum Quantity: 1
Unit: None Selected
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 364
Priority:

Visual and Audible Communications


Finding: There is no directional signage to the accessible restrooms
outside of Building 1.

Alternative *
Rec:
(Where
Available)

Restrooms Outside of Building 1

Full Rec Install directional signage to the accessible restrooms outside of Citation CBC 1117B.5; ADAAG 4.30
Building 1 complying with CBC 1117B.5 and ADAAG 4.30.

Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 188
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 131 of 542


Facility Name: San Joaquin Fairgrounds
Visual and Audible Communications
Finding: Rooms do not have accessible signage mounted on the wall
adjacent to the latch side of the doors.

Alternative *
Rec:
(Where
Available)

Room Signage

Full Rec Install accessible signage identifying each room on the wall Citation CBC 1117B.5; ADAAG 4.30
adjacent to the latch side of the doorway centered at 60 inches
above the finished floor. Signage should be located where a
person may approach within three inches of the sign without Minimum Quantity 1
encountering protruding objects or standing within the swing of Maximum Quantity: 1
the door. Signs shall include raised UPPERCASE
letters/numbers between 5/8 inch and 2 inches in height and Unit: Each
Grade 2 Braille characters. Color and finish shall comply with Minimum Estimated Cost: 58
CBC 1117B.5 and ADAAG 4.30.
Maximum Estimated Cost: 58
Record Number 378
Priority:

Visual and Audible Communications


Finding: The contact device in the Winners Gaming and Sports
Emporium does not have accessible signage mounted on the
wall adjacent to the device.

Alternative *
Rec:
(Where
Available)

Service Bell in the Winners Gaming and Sports Emporium

Full Rec Install compliant informational signage on the wall adjacent to Citation CBC 1117B.5; ADAAG 4.30
the contact device complying with CBC 1117B.5 and ADAAG
4.30.5.
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 180
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 132 of 542


Facility Name: San Joaquin Fairgrounds
Visual and Audible Communications
Finding: The height of the service bell is greater than 48 inches above
the floor for an accessible forward approach reach height.

Alternative *
Rec:
(Where
Available)

Service Bell in the Winners Gaming and Sports Emporium

Full Rec Lower the service bell to provide an accessible forward Citation CBC 1118B.5; ADAAG 4.2.5
approach reach height no greater than 48 inches above the
finished floor.
Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 181
Priority:

Visual and Audible Communications


Finding: There is no signage with the International Symbol of
Accessibility on the entrance door to the facility designating it as
accessible.

Alternative *
Rec:
(Where
Available)

Stable Office

Full Rec The International Symbol of Accessibility shall be the standard Citation CBC 1117B.5.1
used to identify facilities that are accessible to and usable by
physically disabled persons (see CBC 1117B.5.1). All building
entrances that are accessible to and usable by persons with Minimum Quantity 1
disabilities shall be identified with an ISA symbol (see CBC Maximum Quantity: 1
1117B.5.7).
Unit: Each
Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 308
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 133 of 542


Facility Name: San Joaquin Fairgrounds
Visual and Audible Communications
Finding: The main entrance does not have accessible signage mounted
on the wall adjacent to the latch side of the door.

Alternative *
Rec:
(Where
Available)

Stable Office

Full Rec Install signage centered at 60 inches above the finished floor on Citation CBC 1117B.5; ADAAG 4.30
the wall adjacent to the latch side of the entry doorway stating
ENTRANCE from the outside and EXIT from the inside, with
raised UPPERCASE letters between 5/8 inch and 2 inches in Minimum Quantity 1
height and Grade 2 Braille characters. The sign shall comply Maximum Quantity: 1
with the finish and contrast requirements set forth in CBC
1117B.5 and ADAAG 4.30.5. Signage should be located where Unit: Each
a person may approach within three inches of the sign without Minimum Estimated Cost: 58
encountering protruding objects or standing within the swing of
the door. Maximum Estimated Cost: 58
Record Number 309
Priority:

Restrooms
Finding: There is no signage indicating accessibility on the latch side of
the entry door of the restroom. There is no Title 24 gender use
signage on the entrance door.

Alternative *
Rec:
(Where
Available)

Faculty Unisex Restroom at the Grandstands

Full Rec The restroom is designated accessible and should be made Citation CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7));
accessible for the facility. Post signage centered 60 inches ADAAG 4.1.6(3)(e); ADAAG 4.30
above the ground surface on the latch side of the entrance door
identifying the restroom as accessible upon completion of the Minimum Quantity 1
following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG Maximum Quantity: 1
4.1.6(3)(e). Signage shall include Braille and raised lettering,
the gender or unisex use symbol and the ISA symbol. Post Title Unit: Each
24 gender use signage on the door @ 60" o.c. a.f.f. Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 624
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 134 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The entrance door to the restroom has a round doorknob that
requires tight grasping or twisting of the wrist to operate.

Alternative *
Rec:
(Where
Available)

Faculty Unisex Restroom at the Grandstands

Full Rec Replace the door hardware mounted on the restroom complying Citation ADAAG 4.13.9
with ADAAG 4.13.9. Make certain accessible door hardware is
mounted no higher than 48 inches above the finished floor.
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 204
Maximum Estimated Cost: 204
Record Number 625
Priority:

Restrooms
Finding: The height of the urinal rim in the restroom is greater than 17
inches above the finished floor.

Alternative *
Rec:
(Where
Available)

Faculty Unisex Restroom at the Grandstands

Full Rec Lower the urinal designated to be accessible in the restroom so Citation ADAAG 4.18.2
that the rim height is not more than 17 inches above the finished
floor.
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1097
Maximum Estimated Cost: 1097
Record Number 626
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 135 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the urinal flush control in the restroom is greater
than 44 inches above the finished floor.

Alternative *
Rec:
(Where
Available)

Faculty Unisex Restroom at the Grandstands

Full Rec Lower the flush control valve on the urinal designated to be Citation ADAAG 4.18.4
accessible in the restroom to a height not greater than 44 inches
above the finished floor (see ADAAG 4.18.4).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 951
Maximum Estimated Cost: 951
Record Number 627
Priority:

Restrooms
Finding: There is insufficient clear floor space in the stall designated to
be accessible in the restroom. The stall door to the stall
designated to be accessible in the restroom swings inward
limiting the clear floor space in the stall designated to be
accessible. The door to the stall designated to be accessible in
the restroom does not close automatically or have accessible
hardware.

Alternative *
Rec:
(Where
Available)

Faculty Unisex Restroom at the Grandstands

Full Rec Modify or replace the stall designated to be accessible in the Citation CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
restroom so that it complies with ADAAG 4.17.3, CBC 1115B
and CBC Figures 11B-1A and 1B. Standard accessible stalls
require 60 inches in width with 56 inches depth for wall-mounted Minimum Quantity 1
toilets or 59 inches depth for floor-mounted toilets to Maximum Quantity: 1
accommodate individuals in wheelchairs. The minimum width of
a front-approach doorway shall provide at least 32 inches and a Unit: Each
side-approach doorway shall provide at least 34 inches. The Minimum Estimated Cost: 4000
door shall swing outward, close automatically and provide
accessible hardware. Maximum Estimated Cost: 4000
Record Number 628
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 136 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the coat hook on the stall door designated to be
accessible in the restroom is greater than 48 inches above the
floor surface.

Alternative *
Rec:
(Where
Available)

Faculty Unisex Restroom at the Grandstands

Full Rec Remount the coat hook on the stall door designated to be Citation CBC 1115B.9.2; ADAAG A4.27
accessible in the restroom to a maximum height of 48 inches
above the floor surface.
Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 629
Priority:

Restrooms
Finding: There are no grab bars in the stall designated to be accessible
in the restroom.

Alternative *
Rec:
(Where
Available)

Faculty Unisex Restroom at the Grandstands

Full Rec Install one 36-inch back grab bar and one 42/48-inch side grab Citation CBC 1115B.8; ADAAG 4.26
bar in the stall designated to be accessible in the restroom.
Grab bars shall be mounted at a height of 33 inches above the
finished floor. Grab bars must be able to support a point load of Minimum Quantity 1
at least 250 pounds and shall be less than the allowable shear Maximum Quantity: 1
stress of the grab bar material.
Unit: Each
Minimum Estimated Cost: 531
Maximum Estimated Cost: 531
Record Number 630
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 137 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The flush control on the toilet in the stall designated to be
accessible in the restroom is not on the wide (approach) side of
the toilet.

Alternative *
Rec:
(Where
Available)

Faculty Unisex Restroom at the Grandstands

Full Rec Relocate the flush control on the toilet in the stall designated to Citation ADAAG 4.16.5; ADAAG 4.27.4
be accessible in the restroom so that it is on the wide
(approach) side of the toilet area (see ADAAG 4.16.5). Flush
controls shall be hand-operated or automatic mechanisms. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 127
Maximum Estimated Cost: 127
Record Number 631
Priority:

Restrooms
Finding: The height of the toilet seat in the stall designated to be
accessible in the restroom is less than 17 inches above the
finished floor.

Alternative *
Rec:
(Where
Available)

Faculty Unisex Restroom at the Grandstands

Full Rec Remove or modify the toilet in the stall designated to be Citation ADAAG 4.16.3
accessible in the restroom so that the seat height is between 17
inches and 19 inches above the finished floor (see ADAAG
4.16.3). Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1707
Maximum Estimated Cost: 1707
Record Number 632
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 138 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The distance from the center of the toilet to the nearest side
wall in the stall designated to be accessible in the restroom is
greater than 18 inches.

Alternative *
Rec:
(Where
Available)

Faculty Unisex Restroom at the Grandstands

Full Rec Relocate the toilet or stall side wall so that the distance from the Citation CBC 1115B.7.1.3 ADAAG 4.17.3
centerline of the toilet to the nearest side wall in the stall
designated to be accessible in the restroom is exactly 18 inches
(see ADAAG Figure 28. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1143
Maximum Estimated Cost: 1143
Record Number 633
Priority:

Restrooms
Finding: The seat cover dispenser in the stall designated to be
accessible in the restroom is mounted at a height greater than
40 inches and there is no clear floor space.

Alternative *
Rec:
(Where
Available)

Faculty Unisex Restroom at the Grandstands

Full Rec Relocate the seat cover dispenser in the stall designated to be Citation CBC 1115B.9.2
accessible in the restroom so that the height is no greater than
40 inches above the finished floor (see CBC 1115B.9.2). Make
certain that the location of the seat cover dispenser does not Minimum Quantity 1
interfere with the use of a grab bar and provides sufficient clear Maximum Quantity: 1
floor space.
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 634
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 139 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The faucet controls on the lavatory in the restroom require tight
grasping, pinching, or twisting of the wrist and are not
accessible.

Alternative *
Rec:
(Where
Available)

Faculty Unisex Restroom at the Grandstands

Full Rec Install faucet controls complying with ADAAG 4.19.5 on the Citation ADAAG 4.19.5
lavatory designated to be accessible in the restroom. Lever-
operated, push-type, touch-type or electronically controlled
mechanisms are acceptable elements (see ADAAG 4.19.5). If Minimum Quantity 1
self-closing valves are used the faucet shall remain open for at Maximum Quantity: 1
least 10 seconds.
Unit: Each
Minimum Estimated Cost: 392
Maximum Estimated Cost: 392
Record Number 635
Priority:

Restrooms
Finding: The knee clearance space under the lavatory designated to be
accessible in the restroom is less than 29 inches. The knee
depth space under the lavatory designated to be accessible in
the restroom is less than 27 inches at 8 inches under the
lavatory apron.

Alternative *
Rec:
(Where
Available)

Faculty Unisex Restroom at the Grandstands

Full Rec Replace the lavatory designated to be accessible in the Citation ADAAG 4.19.2
restroom to provide at least 29 inches of clear knee space
between the finished floor and bottom of the lavatory apron.
Make sure to provide at least 27 inches at 8 inches under the Minimum Quantity 1
apron (see ADAAG 4.19.2). Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1286
Maximum Estimated Cost: 1286
Record Number 636
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 140 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The pipes under the lavatory in the restroom do not provide
protection against contact.

Alternative *
Rec:
(Where
Available)

Faculty Unisex Restroom at the Grandstands

Full Rec Insulate or otherwise configure pipes under the lavatory Citation ADAAG 4.19.4
designated to be accessible in the restroom to protect against
contact (see ADAAG 4.19.4). Make certain there are no sharp
or abrasive surfaces under the lavatory. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 39
Maximum Estimated Cost: 39
Record Number 637
Priority:

Restrooms
Finding: The bottom edge of the reflecting surface of the mirror in the
restroom is greater than 40 inches above the finished floor.

Alternative *
Rec:
(Where
Available)

Faculty Unisex Restroom at the Grandstands

Full Rec Lower the mirror in the restroom so that the bottom edge of the Citation ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG
reflecting surface is no higher than 40 inches above the finished 4.19.6
floor and the topmost portion of the reflecting surface extends at
least 74 inches above the finished floor (see ADAAG A4.19.6). Minimum Quantity 1
A single, full-length mirror is recommended since it can Maximum Quantity: 1
accommodate all people. Make certain to provide a minimum
clear floor space in front of the mirror of 30 inches in width and Unit: Each
48 inches in length. Minimum Estimated Cost: 291
Maximum Estimated Cost: 291
Record Number 638
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 141 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the controls and operating mechanisms for the
soap dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Faculty Unisex Restroom at the Grandstands

Full Rec Relocate the soap dispenser in the restroom to a maximum Citation CBC 1115B.9.2; ADAAG A4.27
height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 639
Priority:

Restrooms
Finding: The height of the controls and operating mechanisms for the
paper towel dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Faculty Unisex Restroom at the Grandstands

Full Rec Relocate the paper towel dispenser in the restroom to a Citation CBC 1115B.9.2; ADAAG A4.27
maximum height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 640
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 142 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The signage on the latch side of the entry door of the restroom
does not include the International Symbol of Accessibility.
There is no Title 24 gender use signage on the entrance door.

Alternative *
Rec:
(Where
Available)

Faculty Unisex Restroom at the Grandstands (South End)

Full Rec The restroom is designated accessible and should be made Citation CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7));
accessible for the facility. Post signage centered 60 inches ADAAG 4.1.6(3)(e); ADAAG 4.30
above the ground surface on the latch side of the entrance door
identifying the restroom as accessible upon completion of the Minimum Quantity 1
following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG Maximum Quantity: 1
4.1.6(3)(e). Signage shall include Braille and raised lettering,
the gender or unisex use symbol and the ISA symbol. Post Title Unit: Each
24 gender use signage on the door @ 60" o.c. a.f.f. Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 852
Priority:

Restrooms
Finding: The height of the side grab bar in the restroom is greater than
33 inches above the finished floor.

Alternative *
Rec:
(Where
Available)

Faculty Unisex Restroom at the Grandstands (South End)

Full Rec Remount the side grab bar in the restroom so that the height of Citation CBC 1115B.8.1; ADAAG 4.26
the gripping surface is centered at 33 inches above the finished
floor. Grab bars must be able to support a point load of at least
250 pounds and shall be less than the allowable shear stress of Minimum Quantity 1
the grab bar material. Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 448
Maximum Estimated Cost: 448
Record Number 853
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 143 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The side grab bar in the restroom does not extend 54 inches
from the back wall.

Alternative *
Rec:
(Where
Available)

Faculty Unisex Restroom at the Grandstands (South End)

Full Rec The front end of the grab bar shall extend at least 54 inches Citation CBC 1115B.8.1; ADAAG 4.26
from the back wall and the back end of the grab bar shall be
mounted within 12 inches from the back wall. Grab bars must
be able to support a point load of at least 250 pounds and shall Minimum Quantity 1
be less than the allowable shear stress of the grab bar material. Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 531
Maximum Estimated Cost: 531
Record Number 854
Priority:

Restrooms
Finding: The location of the toilet paper dispenser in the restroom is not
within 12 inches of the front edge of the toilet seat.

Alternative *
Rec:
(Where
Available)

Faculty Unisex Restroom at the Grandstands (South End)

Full Rec Remount the toilet paper dispenser in the restroom so that it is Citation CBC 1115B.9.3; ADAAG 4.16.6
within 12 inches from the front edge of the toilet seat and does
not encroach more than four inches from the face of the wall
(see CBC 1115B.9.3 and ADAAG Figure 29(b)). Toilet paper Minimum Quantity 1
dispensers must allow continuous paper flow and shall not Maximum Quantity: 1
interfere with the use of the side grab bar.
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 855
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 144 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The distance from the center of the toilet to the nearest side
wall in the restroom is less than 18 inches.

Alternative *
Rec:
(Where
Available)

Faculty Unisex Restroom at the Grandstands (South End)

Full Rec Relocate the toilet so that the distance from the centerline of the Citation CBC 1115B.7.1.3 ADAAG 4.17.3
toilet to the nearest side wall in the restroom is exactly 18
inches (see ADAAG Figure 28.
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1143
Maximum Estimated Cost: 1143
Record Number 856
Priority:

Restrooms
Finding: The seat cover dispenser in the restroom is mounted at a height
greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Faculty Unisex Restroom at the Grandstands (South End)

Full Rec Relocate the seat cover dispenser in the restroom so that the Citation CBC 1115B.9.2
height is no greater than 40 inches above the finished floor (see
CBC 1115B.9.2). Make certain that the location of the seat
cover dispenser does not interfere with the use of a grab bar Minimum Quantity 1
and provides sufficient clear floor space. Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 857
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 145 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: There is less than 48 inches of clear floor space provided in
front of the water closet in the restroom to allow an accessible
forward approach.

Alternative *
Rec:
(Where
Available)

Faculty Unisex Restroom at the Grandstands (South End)

Full Rec The minimum clear floor space in front of the water closet Citation CBC 1115B.9.4; ADAAG 4.18.3
designated to be accessible in the restroom shall be at least 48
inches to provide an accessible forward approach. Consult a
design professional to determine if elements or walls need to be Minimum Quantity 1
removed to provide sufficient clear floor space in front of the Maximum Quantity: 1
water closet.
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 858
Priority:

Restrooms
Finding: The knee clearance space under the lavatory designated to be
accessible in the restroom is less than 29 inches. The knee
depth space under the lavatory designated to be accessible in
the restroom is less than 27 inches at 8 inches under the
lavatory apron.

Alternative *
Rec:
(Where
Available)

Faculty Unisex Restroom at the Grandstands (South End)

Full Rec Replace the lavatory designated to be accessible in the Citation ADAAG 4.19.2
restroom to provide at least 29 inches of clear knee space
between the finished floor and bottom of the lavatory apron.
Make sure to provide at least 27 inches at 8 inches under the Minimum Quantity 1
apron (see ADAAG 4.19.2). Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1286
Maximum Estimated Cost: 1286
Record Number 859
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 146 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the controls and operating mechanisms for the
soap dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Faculty Unisex Restroom at the Grandstands (South End)

Full Rec Relocate the soap dispenser in the restroom to a maximum Citation CBC 1115B.9.2; ADAAG A4.27
height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 860
Priority:

Restrooms
Finding: The height of the controls and operating mechanisms for the
paper towel dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Faculty Unisex Restroom at the Grandstands (South End)

Full Rec Relocate the paper towel dispenser in the restroom to a Citation CBC 1115B.9.2; ADAAG A4.27
maximum height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 861
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 147 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: There is no signage indicating accessibility on the latch side of
the entry door of the restroom. The gender use signage on the
entrance door is not centered at 60 inches above the floor
surface.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Building 2

Full Rec The restroom is designated accessible and should be made Citation CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7));
accessible for the facility. Post signage centered 60 inches ADAAG 4.1.6(3)(e); ADAAG 4.30
above the ground surface on the latch side of the entrance door
identifying the restroom as accessible upon completion of the Minimum Quantity 1
following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG Maximum Quantity: 1
4.1.6(3)(e). Signage shall include Braille and raised lettering,
the gender or unisex use symbol and the ISA symbol. Post Title Unit: Each
24 gender use signage on the door @ 60" o.c. a.f.f. Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 773
Priority:

Restrooms
Finding: The bottom 10 inches of the door does not provide a smooth,
uninterrupted surface, or panel to allow the door to be opened
by a wheelchair footrest without creating a trap or hazardous
condition, due to the door stop.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Building 2

Full Rec Install a panel or replace the door to provide a smooth, Citation CBC 1133B.2.6
uninterrupted surface for the bottom 10 inches of the door.

Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 774
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 148 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the urinal rim in the restroom is greater than 17
inches above the finished floor.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Building 2

Full Rec Lower the urinal designated to be accessible in the restroom so Citation ADAAG 4.18.2
that the rim height is not more than 17 inches above the finished
floor.
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1097
Maximum Estimated Cost: 1097
Record Number 775
Priority:

Restrooms
Finding: The height of the urinal flush control in the restroom is greater
than 44 inches above the finished floor.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Building 2

Full Rec Lower the flush control valve on the urinal designated to be Citation ADAAG 4.18.4
accessible in the restroom to a height not greater than 44 inches
above the finished floor (see ADAAG 4.18.4).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 951
Maximum Estimated Cost: 951
Record Number 776
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 149 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: There are six stalls located in the multiple accommodation
restroom.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Building 2

Full Rec Create an accessible 36-inch wide alternate stall in addition to Citation CBC 1115B.7.1.4; ADAAG A4.17.3; ADAAG
the required accessible standard stall in the multiple 4.22.4
accommodation restroom. The accessible 36-inch wide
alternate stall shall include an outward swinging, self-closing Minimum Quantity 1
door and parallel side grab bars and shall provide at least 66 Maximum Quantity: 1
inches in length for a stall with a wall-mounted toilet or at least
69 inches in length for a stall with a floor-mounted toilet. Unit: Each
Minimum Estimated Cost: 4000
Maximum Estimated Cost: 4000
Record Number 777
Priority:

Restrooms
Finding: There is insufficient clear floor space in the stall designated to
be accessible in the restroom. The door to the stall designated
to be accessible in the restroom does not close automatically or
have accessible hardware.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Building 2

Full Rec Modify or replace the stall designated to be accessible in the Citation CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
restroom so that it complies with ADAAG 4.17.3, CBC 1115B
and CBC Figures 11B-1A and 1B. Standard accessible stalls
require 60 inches in width with 56 inches depth for wall-mounted Minimum Quantity 1
toilets or 59 inches depth for floor-mounted toilets to Maximum Quantity: 1
accommodate individuals in wheelchairs. The minimum width of
a front-approach doorway shall provide at least 32 inches and a Unit: Each
side-approach doorway shall provide at least 34 inches. The Minimum Estimated Cost: 4000
door shall swing outward, close automatically and provide
accessible hardware. Maximum Estimated Cost: 4000
Record Number 778
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 150 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the coat hook on the stall door designated to be
accessible in the restroom is greater than 48 inches above the
floor surface.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Building 2

Full Rec Remount the coat hook on the stall door designated to be Citation CBC 1115B.9.2; ADAAG A4.27
accessible in the restroom to a maximum height of 48 inches
above the floor surface.
Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 779
Priority:

Restrooms
Finding: There is no back grab bar in the stall designated to be
accessible in the restroom.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Building 2

Full Rec Install a 36-inch back grab bar at a height of 33 inches above Citation CBC 1115B.8.1; ADAAG 4.26
the finished floor in the stall designated to be accessible of the
restroom. Grab bars must be able to support a point load of at
least 250 pounds and shall be less than the allowable shear Minimum Quantity 1
stress of the grab bar material. Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 531
Maximum Estimated Cost: 531
Record Number 780
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 151 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the side grab bars in the stall designated to be
accessible of the restroom is less than 33 inches above the
finished floor.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Building 2

Full Rec Remount the side grab bars in the stall designated to be Citation CBC 1115B.8.1; ADAAG 4.26
accessible in the restroom so that the height of the gripping
surface is centered at 33 inches above finished floor. Grab bars
must be able to support a point load of at least 250 pounds and Minimum Quantity 1
shall be less than the allowable shear stress of the grab bar Maximum Quantity: 1
material.
Unit: Each
Minimum Estimated Cost: 448
Maximum Estimated Cost: 448
Record Number 781
Priority:

Restrooms
Finding: The flush control on the toilet in the stall designated to be
accessible in the restroom is not on the wide (approach) side of
the toilet.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Building 2

Full Rec Relocate the flush control on the toilet in the stall designated to Citation ADAAG 4.16.5; ADAAG 4.27.4
be accessible in the restroom so that it is on the wide
(approach) side of the toilet area (see ADAAG 4.16.5). Flush
controls shall be hand-operated or automatic mechanisms. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 127
Maximum Estimated Cost: 127
Record Number 783
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 152 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the toilet seat in the stall designated to be
accessible in the restroom is less than 17 inches above the
finished floor.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Building 2

Full Rec Remove or modify the toilet in the stall designated to be Citation ADAAG 4.16.3
accessible in the restroom so that the seat height is between 17
inches and 19 inches above the finished floor (see ADAAG
4.16.3). Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1707
Maximum Estimated Cost: 1707
Record Number 784
Priority:

Restrooms
Finding: The distance from the center of the toilet to the nearest side
wall in the stall designated to be accessible in the restroom is
greater than 18 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Building 2

Full Rec Relocate the toilet or stall side wall so that the distance from the Citation CBC 1115B.7.1.3 ADAAG 4.17.3
centerline of the toilet to the nearest side wall in the stall
designated to be accessible in the restroom is exactly 18 inches
(see ADAAG Figure 28. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1143
Maximum Estimated Cost: 1143
Record Number 785
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 153 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The knee clearance space under the lavatory designated to be
accessible in the restroom is less than 29 inches. The knee
depth space under the lavatory designated to be accessible in
the restroom is less than 27 inches at 8 inches under the
lavatory apron.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Building 2

Full Rec Replace the lavatory designated to be accessible in the Citation ADAAG 4.19.2
restroom to provide at least 29 inches of clear knee space
between the finished floor and bottom of the lavatory apron.
Make sure to provide at least 27 inches at 8 inches under the Minimum Quantity 1
apron (see ADAAG 4.19.2). Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1286
Maximum Estimated Cost: 1286
Record Number 786
Priority:

Restrooms
Finding: The pipes under the lavatory in the restroom do not provide
protection against contact.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Building 2

Full Rec Insulate or otherwise configure pipes under the lavatory Citation ADAAG 4.19.4
designated to be accessible in the restroom to protect against
contact (see ADAAG 4.19.4). Make certain there are no sharp
or abrasive surfaces under the lavatory. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 39
Maximum Estimated Cost: 39
Record Number 787
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 154 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The bottom edge of the reflecting surface of the mirror in the
restroom is greater than 40 inches above the finished floor.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Building 2

Full Rec Lower the mirror in the restroom so that the bottom edge of the Citation ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG
reflecting surface is no higher than 40 inches above the finished 4.19.6
floor and the topmost portion of the reflecting surface extends at
least 74 inches above the finished floor (see ADAAG A4.19.6). Minimum Quantity 1
A single, full-length mirror is recommended since it can Maximum Quantity: 1
accommodate all people. Make certain to provide a minimum
clear floor space in front of the mirror of 30 inches in width and Unit: Each
48 inches in length. Minimum Estimated Cost: 291
Maximum Estimated Cost: 291
Record Number 788
Priority:

Restrooms
Finding: The height of the controls and operating mechanisms for the
paper towel dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Building 2

Full Rec Relocate the paper towel dispenser in the restroom to a Citation CBC 1115B.9.2; ADAAG A4.27
maximum height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 789
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 155 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: There is no signage indicating accessibility on the latch side of
the entry door of the restroom. There is no Title 24 gender use
signage on the entrance door.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Building 4

Full Rec The restroom is designated accessible and should be made Citation CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7));
accessible for the facility. Post signage centered 60 inches ADAAG 4.1.6(3)(e); ADAAG 4.30
above the ground surface on the latch side of the entrance door
identifying the restroom as accessible upon completion of the Minimum Quantity 1
following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG Maximum Quantity: 1
4.1.6(3)(e). Signage shall include Braille and raised lettering,
the gender or unisex use symbol and the ISA symbol. Post Title Unit: Each
24 gender use signage on the door @ 60" o.c. a.f.f. Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 520
Priority:

Restrooms
Finding: The bottom 10 inches of the door does not provide a smooth,
uninterrupted surface, or panel to allow the door to be opened
by a wheelchair footrest without creating a trap or hazardous
condition, due to the door stop.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Building 4

Full Rec Install a panel or replace the door to provide a smooth, Citation CBC 1133B.2.6
uninterrupted surface for the bottom 10 inches of the door.

Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 521
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 156 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: There is less than 12 inches of latch side clearance from the
push side of the entrance door.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Building 4

Full Rec Consult a design professional to determine if it is technically Citation ADAAG 4.13.6
feasible to provide at least 12 inches of latch side clearance at
the entrance door from the push side (see ADAAG 4.13.6 and
Figure 25). Otherwise, install an automatic door opening device Minimum Quantity 1
to the primary entrance complying with ADAAG 4.13.12 and Maximum Quantity: 1
ANSI/BHMA A156.10, 1985, standards.
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 522
Priority:

Restrooms
Finding: The clear opening width of the entrance doorway to the
restroom is less than 32 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Building 4

Full Rec Widen the entrance doorway to the restroom to provide a clear Citation ADAAG 4.13.5
opening width of at least 32 inches when the door is open 90
degrees (see ADAAG 4.13.5).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 750
Maximum Estimated Cost: 750
Record Number 523
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 157 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the urinal rim in the restroom is greater than 17
inches above the finished floor.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Building 4

Full Rec Lower the urinal designated to be accessible in the restroom so Citation ADAAG 4.18.2
that the rim height is not more than 17 inches above the finished
floor.
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1097
Maximum Estimated Cost: 1097
Record Number 524
Priority:

Restrooms
Finding: The height of the urinal flush control in the restroom is greater
than 44 inches above the finished floor.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Building 4

Full Rec Lower the flush control valve on the urinal designated to be Citation ADAAG 4.18.4
accessible in the restroom to a height not greater than 44 inches
above the finished floor (see ADAAG 4.18.4).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 951
Maximum Estimated Cost: 951
Record Number 525
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 158 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: There is insufficient clear floor space in the stall designated to
be accessible in the restroom. The door to the stall designated
to be accessible in the restroom does not have accessible
hardware.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Building 4

Full Rec Modify or replace the stall designated to be accessible in the Citation CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
restroom so that it complies with ADAAG 4.17.3, CBC 1115B
and CBC Figures 11B-1A and 1B. Standard accessible stalls
require 60 inches in width with 56 inches depth for wall-mounted Minimum Quantity 1
toilets or 59 inches depth for floor-mounted toilets to Maximum Quantity: 1
accommodate individuals in wheelchairs. The minimum width of
a front-approach doorway shall provide at least 32 inches and a Unit: Each
side-approach doorway shall provide at least 34 inches. The Minimum Estimated Cost: 4000
door shall swing outward, close automatically and provide
accessible hardware. Maximum Estimated Cost: 4000
Record Number 526
Priority:

Restrooms
Finding: The height of the coat hook on the stall door designated to be
accessible in the restroom is greater than 48 inches above the
floor surface.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Building 4

Full Rec Remount the coat hook on the stall door designated to be Citation CBC 1115B.9.2; ADAAG A4.27
accessible in the restroom to a maximum height of 48 inches
above the floor surface.
Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 527
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 159 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: There is no back grab bar in the stall designated to be
accessible in the restroom.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Building 4

Full Rec Install a 36-inch back grab bar at a height of 33 inches above Citation CBC 1115B.8.1; ADAAG 4.26
the finished floor in the stall designated to be accessible of the
restroom. Grab bars must be able to support a point load of at
least 250 pounds and shall be less than the allowable shear Minimum Quantity 1
stress of the grab bar material. Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 531
Maximum Estimated Cost: 531
Record Number 528
Priority:

Restrooms
Finding: The height of the side grab bars in the stall designated to be
accessible of the restroom is greater than 33 inches above the
finished floor.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Building 4

Full Rec Remount the side grab bars in the stall designated to be Citation CBC 1115B.8.1; ADAAG 4.26
accessible in the restroom so that the height of the gripping
surface is centered at 33 inches above finished floor. Grab bars
must be able to support a point load of at least 250 pounds and Minimum Quantity 1
shall be less than the allowable shear stress of the grab bar Maximum Quantity: 1
material.
Unit: Each
Minimum Estimated Cost: 448
Maximum Estimated Cost: 448
Record Number 529
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 160 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The side grab bars in the stall designated to be accessible in
the restroom do not extend 54 inches from the back wall.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Building 4

Full Rec The front end of the grab bars shall extend at least 54 inches Citation CBC 1115B.8.1; ADAAG 4.26
from the back wall and the back end of the grab bar shall be
mounted within 12 inches from the back wall. Grab bars must
be able to support a point load of at least 250 pounds and shall Minimum Quantity 1
be less than the allowable shear stress of the grab bar material. Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 531
Maximum Estimated Cost: 531
Record Number 530
Priority:

Restrooms
Finding: The flush control on the toilet in the stall designated to be
accessible in the restroom is nonaccessible and requires the
use of foot controls to operate.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Building 4

Full Rec Flush controls shall be hand-operated or automatic mechanisms. Citation ADAAG 4.16.5; ADAAG 4.27.4

Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 531
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 161 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The distance from the center of the toilet to the nearest side
wall in the stall designated to be accessible in the restroom is
greater than 18 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Building 4

Full Rec Relocate the toilet or stall side wall so that the distance from the Citation CBC 1115B.7.1.3 ADAAG 4.17.3
centerline of the toilet to the nearest side wall in the stall
designated to be accessible in the restroom is exactly 18 inches
(see ADAAG Figure 28. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1143
Maximum Estimated Cost: 1143
Record Number 532
Priority:

Restrooms
Finding: The seat cover dispenser in the stall designated to be
accessible in the restroom is mounted at a height greater than
40 inches and there is no clear floor space.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Building 4

Full Rec Relocate the seat cover dispenser in the stall designated to be Citation CBC 1115B.9.2
accessible in the restroom so that the height is no greater than
40 inches above the finished floor (see CBC 1115B.9.2). Make
certain that the location of the seat cover dispenser does not Minimum Quantity 1
interfere with the use of a grab bar and provides sufficient clear Maximum Quantity: 1
floor space.
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 533
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 162 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The faucet controls on the lavatory in the restroom require tight
grasping, pinching, or twisting of the wrist and are not
accessible.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Building 4

Full Rec Install faucet controls complying with ADAAG 4.19.5 on the Citation ADAAG 4.19.5
lavatory designated to be accessible in the restroom. Lever-
operated, push-type, touch-type or electronically controlled
mechanisms are acceptable elements (see ADAAG 4.19.5). If Minimum Quantity 1
self-closing valves are used the faucet shall remain open for at Maximum Quantity: 1
least 10 seconds.
Unit: Each
Minimum Estimated Cost: 392
Maximum Estimated Cost: 392
Record Number 534
Priority:

Restrooms
Finding: The knee clearance space under the lavatory designated to be
accessible in the restroom is less than 29 inches. The knee
depth space under the lavatory designated to be accessible in
the restroom is less than 27 inches at 8 inches under the
lavatory apron.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Building 4

Full Rec Replace the lavatory designated to be accessible in the Citation ADAAG 4.19.2
restroom to provide at least 29 inches of clear knee space
between the finished floor and bottom of the lavatory apron.
Make sure to provide at least 27 inches at 8 inches under the Minimum Quantity 1
apron (see ADAAG 4.19.2). Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1286
Maximum Estimated Cost: 1286
Record Number 535
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 163 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The pipes under the lavatory in the restroom do not provide
protection against contact.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Building 4

Full Rec Insulate or otherwise configure pipes under the lavatory Citation ADAAG 4.19.4
designated to be accessible in the restroom to protect against
contact (see ADAAG 4.19.4). Make certain there are no sharp
or abrasive surfaces under the lavatory. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 39
Maximum Estimated Cost: 39
Record Number 536
Priority:

Restrooms
Finding: The bottom edge of the reflecting surface of the mirror in the
restroom is greater than 40 inches above the finished floor.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Building 4

Full Rec Lower the mirror in the restroom so that the bottom edge of the Citation ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG
reflecting surface is no higher than 40 inches above the finished 4.19.6
floor and the topmost portion of the reflecting surface extends at
least 74 inches above the finished floor (see ADAAG A4.19.6). Minimum Quantity 1
A single, full-length mirror is recommended since it can Maximum Quantity: 1
accommodate all people. Make certain to provide a minimum
clear floor space in front of the mirror of 30 inches in width and Unit: Each
48 inches in length. Minimum Estimated Cost: 291
Maximum Estimated Cost: 291
Record Number 537
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 164 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the controls and operating mechanisms for the
soap dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Building 4

Full Rec Relocate the soap dispenser in the restroom to a maximum Citation CBC 1115B.9.2; ADAAG A4.27
height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 538
Priority:

Restrooms
Finding: The height of the controls and operating mechanisms for the
paper towel dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Building 4

Full Rec Relocate the paper towel dispenser in the restroom to a Citation CBC 1115B.9.2; ADAAG A4.27
maximum height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 539
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 165 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: There is no signage indicating accessibility on the latch side of
the entry door of the restroom. There is no Title 24 gender use
signage on the entrance door.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Building 5

Full Rec The restroom is designated accessible and should be made Citation CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7));
accessible for the facility. Post signage centered 60 inches ADAAG 4.1.6(3)(e); ADAAG 4.30
above the ground surface on the latch side of the entrance door
identifying the restroom as accessible upon completion of the Minimum Quantity 1
following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG Maximum Quantity: 1
4.1.6(3)(e). Signage shall include Braille and raised lettering,
the gender or unisex use symbol and the ISA symbol. Post Title Unit: Each
24 gender use signage on the door @ 60" o.c. a.f.f. Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 961
Priority:

Restrooms
Finding: The clear opening width of the entrance doorway to the
restroom is less than 32 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Building 5

Full Rec Widen the entrance doorway to the restroom to provide a clear Citation ADAAG 4.13.5
opening width of at least 32 inches when the door is open 90
degrees (see ADAAG 4.13.5).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 750
Maximum Estimated Cost: 750
Record Number 962
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 166 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The entrance door to the restroom has a round doorknob that
requires tight grasping or twisting of the wrist to operate.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Building 5

Full Rec Replace the door hardware mounted on the restroom complying Citation ADAAG 4.13.9
with ADAAG 4.13.9. Make certain accessible door hardware is
mounted no higher than 48 inches above the finished floor.
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 204
Maximum Estimated Cost: 204
Record Number 963
Priority:

Restrooms
Finding: The bottom 10 inches of the door does not provide a smooth,
uninterrupted surface, or panel to allow the door to be opened
by a wheelchair footrest without creating a trap or hazardous
condition, due to the doorstop.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Building 5

Full Rec Install a panel or replace the door to provide a smooth, Citation CBC 1133B.2.6
uninterrupted surface for the bottom 10 inches of the door.

Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 964
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 167 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The urinal in the restroom does not extend at least 14 inches
from the back wall. The height of the urinal rim is greater than
17 inches above the finished floor. The flush control valve on
the urinal is greater than 44 inches above the finished floor.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Building 5

Full Rec Replace the urinal designated to be accessible in the restroom Citation ADAAG 4.18.2
with a wall-mounted or stall-type tapered, elongated rim unit
complying with ADAAG 4.18.2. The height of the rim surface of
the urinal designated to be accessible shall not exceed 17 Minimum Quantity 1
inches above the finished floor and the flush control valve shall Maximum Quantity: 1
not exceed a height of 44 inches above the finished floor.
Unit: Each
Minimum Estimated Cost: 951
Maximum Estimated Cost: 951
Record Number 965
Priority:

Restrooms
Finding: There is less than 30 inches by 48 inches of clear floor space
provided in front of the urinal in the restroom to allow an
accessible forward approach.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Building 5

Full Rec The minimum clear floor space in front of the urinal designated Citation CBC 1115B.9.4; ADAAG 4.18.3
to be accessible in the restroom shall be at least 30 inches by
48 inches to provide an accessible forward approach (see CBC
1115B.9.4 and ADAAG 4.18.3). Consult a design professional Minimum Quantity 1
to determine if elements or walls need to be removed to provide Maximum Quantity: 1
sufficient clear floor space in front of the urinal.
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 966
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 168 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The latch side approach to the stall designated to be accessible
in the restroom is less than 44 inches wide.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Building 5

Full Rec Consult a design professional to provide a latch-side approach Citation CBC 1115B.7.1.3; ADAAG 4.17.3
to the stall designated to be accessible with a clear,
unobstructed access width of 44 inches with the space
immediately in front of the stall door at 48 inches in width. All Minimum Quantity 1
other approaches require 48 inches of clear, unobstructed Maximum Quantity: 1
access to and in front of the stall designated to be accessible in
the restroom. Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 967
Priority:

Restrooms
Finding: There is insufficient clear floor space in the stall designated to
be accessible in the restroom. The inside handle on the stall
door is not mounted immediately below the latch.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Building 5

Full Rec Modify or replace the stall designated to be accessible in the Citation CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
restroom so that it complies with ADAAG 4.17.3, CBC 1115B
and CBC Figures 11B-1A and 1B. Standard accessible stalls
require 60 inches in width with 56 inches depth for wall-mounted Minimum Quantity 1
toilets or 59 inches depth for floor-mounted toilets to Maximum Quantity: 1
accommodate individuals in wheelchairs. The minimum width of
a front-approach doorway shall provide at least 32 inches and a Unit: Each
side-approach doorway shall provide at least 34 inches. The Minimum Estimated Cost: 4000
door shall swing outward, close automatically and provide
accessible hardware. Maximum Estimated Cost: 4000
Record Number 968
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 169 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the side grab bar in the stall designated to be
accessible of the restroom is greater than 33 inches above the
finished floor.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Building 5

Full Rec Remount the side grab bar in the stall designated to be Citation CBC 1115B.8.1; ADAAG 4.26
accessible in the restroom so that the height of the gripping
surface is centered at 33 inches above finished floor. Grab bars
must be able to support a point load of at least 250 pounds and Minimum Quantity 1
shall be less than the allowable shear stress of the grab bar Maximum Quantity: 1
material.
Unit: Each
Minimum Estimated Cost: 448
Maximum Estimated Cost: 448
Record Number 969
Priority:

Restrooms
Finding: The distance from the end of the back grab bar to the nearest
side wall in the stall designated to be accessible of the restroom
is greater than 6 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Building 5

Full Rec Remount the back grab bar in the stall designated to be Citation ADAAG 4.26; CBC 1115B.8.1
accessible in the restroom so that it is not more than 6 inches
from the nearest side wall (see ADAAG 4.26 and CBC Figure
11B.1A-1C). Grab bars must be able to support a point load of Minimum Quantity 1
at least 250 pounds and shall be less than the allowable shear Maximum Quantity: 1
stress of the grab bar material.
Unit: Each
Minimum Estimated Cost: 448
Maximum Estimated Cost: 448
Record Number 970
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 170 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The side grab bar in the stall designated to be accessible in the
restroom does not extend 54 inches from the back wall.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Building 5

Full Rec The front end of the grab bar shall extend at least 54 inches Citation CBC 1115B.8.1; ADAAG 4.26
from the back wall and the back end of the grab bar shall be
mounted within 12 inches from the back wall. Grab bars must
be able to support a point load of at least 250 pounds and shall Minimum Quantity 1
be less than the allowable shear stress of the grab bar material. Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 531
Maximum Estimated Cost: 531
Record Number 971
Priority:

Restrooms
Finding: The distance from the center of the toilet to the nearest side
wall in the stall designated to be accessible in the restroom is
greater than 18 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Building 5

Full Rec Relocate the toilet or stall side wall so that the distance from the Citation CBC 1115B.7.1.3 ADAAG 4.17.3
centerline of the toilet to the nearest side wall in the stall
designated to be accessible in the restroom is exactly 18 inches
(see ADAAG Figure 28. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1143
Maximum Estimated Cost: 1143
Record Number 973
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 171 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: There is no clear floor space provided in front of the seat cover
dispenser.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Building 5

Full Rec Relocate the seat cover dispenser in the stall designated to be Citation CBC 1115B.9.2
accessible in the restroom so that the height is no greater than
40 inches above the finished floor (see CBC 1115B.9.2). Make
certain that the location of the seat cover dispenser does not Minimum Quantity 1
interfere with the use of a grab bar and provides sufficient clear Maximum Quantity: 1
floor space.
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 974
Priority:

Restrooms
Finding: The height of the controls and operating mechanisms for the
soap dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Building 5

Full Rec Relocate the soap dispenser in the restroom to a maximum Citation CBC 1115B.9.2; ADAAG A4.27
height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 975
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 172 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the controls and operating mechanisms for the
paper towel dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Building 5

Full Rec Relocate the paper towel dispenser in the restroom to a Citation CBC 1115B.9.2; ADAAG A4.27
maximum height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 976
Priority:

Restrooms
Finding: There is no signage indicating accessibility on the latch side of
the entry door of the restroom. The gender use signage on the
entrance door is not centered at 60 inches above the floor
surface.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Flats BBQ

Full Rec The restroom is designated accessible and should be made Citation CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7));
accessible for the facility. Post signage centered 60 inches ADAAG 4.1.6(3)(e); ADAAG 4.30
above the ground surface on the latch side of the entrance door
identifying the restroom as accessible upon completion of the Minimum Quantity 1
following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG Maximum Quantity: 1
4.1.6(3)(e). Signage shall include Braille and raised lettering,
the gender or unisex use symbol and the ISA symbol. Post Title Unit: Each
24 gender use signage on the door @ 60" o.c. a.f.f. Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 431
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 173 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The door opening force for the interior entrance door to the
restroom is greater than 5 pounds.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Flats BBQ

Full Rec Adjust the closer on the interior entrance door to the restroom to Citation CBC 1133B.2.5.1; ADAAG 4.13.11
a maximum door opening force of 5 pounds (see CBC
1133B.2.5.1 and ADAAG 4.13.11).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 5
Maximum Estimated Cost: 5
Record Number 432
Priority:

Restrooms
Finding: There is insufficient clear floor space in the stall designated to
be accessible in the restroom. The door to the stall designated
to be accessible in the restroom does not close automatically.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Flats BBQ

Full Rec Modify or replace the stall designated to be accessible in the Citation CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
restroom so that it complies with ADAAG 4.17.3, CBC 1115B
and CBC Figures 11B-1A and 1B. Standard accessible stalls
require 60 inches in width with 56 inches depth for wall-mounted Minimum Quantity 1
toilets or 59 inches depth for floor-mounted toilets to Maximum Quantity: 1
accommodate individuals in wheelchairs. The minimum width of
a front-approach doorway shall provide at least 32 inches and a Unit: Each
side-approach doorway shall provide at least 34 inches. The Minimum Estimated Cost: 4000
door shall swing outward, close automatically and provide
accessible hardware. Maximum Estimated Cost: 4000
Record Number 433
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 174 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The distance from the end of the back grab bar to the nearest
side wall in the stall designated to be accessible of the restroom
is greater than 6 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Flats BBQ

Full Rec Remount the back grab bar in the stall designated to be Citation ADAAG 4.26; CBC 1115B.8.1
accessible in the restroom so that it is not more than 6 inches
from the nearest side wall (see ADAAG 4.26 and CBC Figure
11B.1A-1C). Grab bars must be able to support a point load of Minimum Quantity 1
at least 250 pounds and shall be less than the allowable shear Maximum Quantity: 1
stress of the grab bar material.
Unit: Each
Minimum Estimated Cost: 448
Maximum Estimated Cost: 448
Record Number 434
Priority:

Restrooms
Finding: The side grab bar in the stall designated to be accessible in the
restroom does not extend 54 inches from the back wall.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Flats BBQ

Full Rec The front end of the grab bar shall extend at least 54 inches Citation CBC 1115B.8.1; ADAAG 4.26
from the back wall and the back end of the grab bar shall be
mounted within 12 inches from the back wall. Grab bars must
be able to support a point load of at least 250 pounds and shall Minimum Quantity 1
be less than the allowable shear stress of the grab bar material. Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 531
Maximum Estimated Cost: 531
Record Number 435
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 175 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the toilet seat in the stall designated to be
accessible in the restroom is greater than 19 inches above the
finished floor.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Flats BBQ

Full Rec Remove or modify the toilet in the stall designated to be Citation ADAAG 4.16.3
accessible in the restroom so that the seat height is between 17
inches and 19 inches above the finished floor (see ADAAG
4.16.3). Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1707
Maximum Estimated Cost: 1707
Record Number 436
Priority:

Restrooms
Finding: The distance from the center of the toilet to the nearest side
wall in the stall designated to be accessible in the restroom is
less than 18 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Flats BBQ

Full Rec Relocate the toilet or stall side wall so that the distance from the Citation CBC 1115B.7.1.3 ADAAG 4.17.3
centerline of the toilet to the nearest side wall in the stall
designated to be accessible in the restroom is exactly 18 inches
(see ADAAG Figure 28. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1143
Maximum Estimated Cost: 1143
Record Number 437
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 176 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: There is no clear floor space provided in front of the seat cover
dispenser.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Flats BBQ

Full Rec Relocate the seat cover dispenser in the stall designated to be Citation CBC 1115B.9.2
accessible in the restroom so that the height is no greater than
40 inches above the finished floor (see CBC 1115B.9.2). Make
certain that the location of the seat cover dispenser does not Minimum Quantity 1
interfere with the use of a grab bar and provides sufficient clear Maximum Quantity: 1
floor space.
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 438
Priority:

Restrooms
Finding: The knee clearance space under the lavatory designated to be
accessible in the restroom is less than 29 inches. The knee
depth space under the lavatory designated to be accessible in
the restroom is less than 27 inches at 8 inches under the
lavatory apron.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Flats BBQ

Full Rec Raise or replace the lavatory designated to be accessible in the Citation ADAAG 4.19.2
restroom to provide at least 29 inches of clear knee space
between the finished floor and bottom of the lavatory apron.
Make sure to provide at least 27 inches at 8 inches under the Minimum Quantity 1
apron (see ADAAG 4.19.2). Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1286
Maximum Estimated Cost: 1286
Record Number 439
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 177 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The pipes under the lavatory in the restroom do not provide
protection against contact.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Flats BBQ

Full Rec Insulate or otherwise configure pipes under the lavatory Citation ADAAG 4.19.4
designated to be accessible in the restroom to protect against
contact (see ADAAG 4.19.4). Make certain there are no sharp
or abrasive surfaces under the lavatory. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 39
Maximum Estimated Cost: 39
Record Number 440
Priority:

Restrooms
Finding: The signage on the latch side of the entry door of the restroom
does not include the International Symbol of Accessibility and is
not centered at 60 inches above the floor surface. There is no
Title 24 gender use signage on the entrance door.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Horse Barn 2

Full Rec The restroom is designated accessible and should be made Citation CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7));
accessible for the facility. Post signage centered 60 inches ADAAG 4.1.6(3)(e); ADAAG 4.30
above the ground surface on the latch side of the entrance door
identifying the restroom as accessible upon completion of the Minimum Quantity 1
following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG Maximum Quantity: 1
4.1.6(3)(e). Signage shall include Braille and raised lettering,
the gender or unisex use symbol and the ISA symbol. Post Title Unit: Each
24 gender use signage on the door @ 60" o.c. a.f.f. Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 559
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 178 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the urinal rim in the restroom is greater than 17
inches above the finished floor.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Horse Barn 2

Full Rec Lower the urinal designated to be accessible in the restroom so Citation ADAAG 4.18.2
that the rim height is not more than 17 inches above the finished
floor.
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1097
Maximum Estimated Cost: 1097
Record Number 560
Priority:

Restrooms
Finding: The height of the urinal flush control in the restroom is greater
than 44 inches above the finished floor.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Horse Barn 2

Full Rec Lower the flush control valve on the urinal designated to be Citation ADAAG 4.18.4
accessible in the restroom to a height not greater than 44 inches
above the finished floor (see ADAAG 4.18.4).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 951
Maximum Estimated Cost: 951
Record Number 561
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 179 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: There is insufficient clear floor space in the stall designated to
be accessible in the restroom. The stall door to the stall
designated to be accessible in the restroom swings inward
limiting the clear floor space in the stall designated to be
accessible. The door to the stall designated to be accessible in
the restroom does not close automatically or have accessible
hardware.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Horse Barn 2

Full Rec Modify or replace the stall designated to be accessible in the Citation CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
restroom so that it complies with ADAAG 4.17.3, CBC 1115B
and CBC Figures 11B-1A and 1B. Standard accessible stalls
require 60 inches in width with 56 inches depth for wall-mounted Minimum Quantity 1
toilets or 59 inches depth for floor-mounted toilets to Maximum Quantity: 1
accommodate individuals in wheelchairs. The minimum width of
a front-approach doorway shall provide at least 32 inches and a Unit: Each
side-approach doorway shall provide at least 34 inches. The Minimum Estimated Cost: 4000
door shall swing outward, close automatically and provide
accessible hardware. Maximum Estimated Cost: 4000
Record Number 562
Priority:

Restrooms
Finding: There are no grab bars in the stall designated to be accessible
in the restroom.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Horse Barn 2

Full Rec Install one 36-inch back grab bar and one 42/48-inch side grab Citation CBC 1115B.8; ADAAG 4.26
bar in the stall designated to be accessible in the restroom.
Grab bars shall be mounted at a height of 33 inches above the
finished floor. Grab bars must be able to support a point load of Minimum Quantity 1
at least 250 pounds and shall be less than the allowable shear Maximum Quantity: 1
stress of the grab bar material.
Unit: Each
Minimum Estimated Cost: 531
Maximum Estimated Cost: 531
Record Number 563
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 180 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the toilet seat in the stall designated to be
accessible in the restroom is less than 17 inches above the
finished floor.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Horse Barn 2

Full Rec Remove or modify the toilet in the stall designated to be Citation ADAAG 4.16.3
accessible in the restroom so that the seat height is between 17
inches and 19 inches above the finished floor (see ADAAG
4.16.3). Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1707
Maximum Estimated Cost: 1707
Record Number 564
Priority:

Restrooms
Finding: The distance from the center of the toilet to the nearest side
wall in the stall designated to be accessible in the restroom is
less than 18 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Horse Barn 2

Full Rec Relocate the toilet or stall side wall so that the distance from the Citation CBC 1115B.7.1.3 ADAAG 4.17.3
centerline of the toilet to the nearest side wall in the stall
designated to be accessible in the restroom is exactly 18 inches
(see ADAAG Figure 28. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1143
Maximum Estimated Cost: 1143
Record Number 565
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 181 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The seat cover dispenser in the stall designated to be
accessible in the restroom is mounted at a height greater than
40 inches and there is no clear floor space.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Horse Barn 2

Full Rec Relocate the seat cover dispenser in the stall designated to be Citation CBC 1115B.9.2
accessible in the restroom so that the height is no greater than
40 inches above the finished floor (see CBC 1115B.9.2). Make
certain that the location of the seat cover dispenser does not Minimum Quantity 1
interfere with the use of a grab bar and provides sufficient clear Maximum Quantity: 1
floor space.
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 566
Priority:

Restrooms
Finding: The pipes under the lavatory in the restroom do not provide
protection against contact.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Horse Barn 2

Full Rec Insulate or otherwise configure pipes under the lavatory Citation ADAAG 4.19.4
designated to be accessible in the restroom to protect against
contact (see ADAAG 4.19.4). Make certain there are no sharp
or abrasive surfaces under the lavatory. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 39
Maximum Estimated Cost: 39
Record Number 567
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 182 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The bottom edge of the reflecting surface of the mirror in the
restroom is greater than 40 inches above the finished floor.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Horse Barn 2

Full Rec Lower the mirror in the restroom so that the bottom edge of the Citation ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG
reflecting surface is no higher than 40 inches above the finished 4.19.6
floor and the topmost portion of the reflecting surface extends at
least 74 inches above the finished floor (see ADAAG A4.19.6). Minimum Quantity 1
A single, full-length mirror is recommended since it can Maximum Quantity: 1
accommodate all people. Make certain to provide a minimum
clear floor space in front of the mirror of 30 inches in width and Unit: Each
48 inches in length. Minimum Estimated Cost: 291
Maximum Estimated Cost: 291
Record Number 568
Priority:

Restrooms
Finding: The height of the controls and operating mechanisms for the
soap dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Horse Barn 2

Full Rec Relocate the soap dispenser in the restroom to a maximum Citation CBC 1115B.9.2; ADAAG A4.27
height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 569
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 183 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the controls and operating mechanisms for the
paper towel dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Horse Barn 2

Full Rec Relocate the paper towel dispenser in the restroom to a Citation CBC 1115B.9.2; ADAAG A4.27
maximum height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 570
Priority:

Restrooms
Finding: There are no accessible shower stalls provided in the restroom.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Horse Barn 2

Full Rec Since shower stalls are provided in the restroom, at least one Citation CBC 1115B.6.2; ADAAG 4.21
accessible shower stall is required. Install an accessible shower
stall complying with CBC 1115B 6.2 and ADAAG 4.21 in the
restroom. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 2853
Maximum Estimated Cost: 2853
Record Number 571
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 184 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: There is no signage indicating accessibility on the latch side of
the entry door of the restroom.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Horse Barn N

Full Rec The restroom is designated accessible and should be made Citation CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7));
accessible for the facility. Post signage centered 60 inches ADAAG 4.1.6(3)(e); ADAAG 4.30
above the ground surface on the latch side of the entrance door
identifying the restroom as accessible upon completion of the Minimum Quantity 1
following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG Maximum Quantity: 1
4.1.6(3)(e). Signage shall include Braille and raised lettering,
the gender or unisex use symbol and the ISA symbol. Unit: Each
Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 1043
Priority:

Restrooms
Finding: The privacy partition at the entrance limits the minimum clear
width of the accessible route into the restroom.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Horse Barn N

Full Rec Modify or remove the privacy partition at the entrance to the Citation CBC 1133B.2.4.2; ADAAG 4.13.6
restroom to provide a width of at least 60 inches in the direction
of the door swing and at least 48 inches in the opposite direction
of the door swing (see CBC 1133B.2.4.2, ADAAG 4.13.6 and Minimum Quantity 1
ADAAG Figure 25). Maximum Quantity: 1
Unit: 128 Sq Ft
Minimum Estimated Cost: 1024
Maximum Estimated Cost: 1024
Record Number 1044
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 185 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: There is insufficient clear floor space in the stall designated to
be accessible in the restroom. The stall door to the stall
designated to be accessible in the restroom swings inward
limiting the clear floor space in the stall designated to be
accessible. The door to the stall designated to be accessible in
the restroom does not close automatically or have accessible
hardware.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Horse Barn N

Full Rec Modify or replace the stall designated to be accessible in the Citation CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
restroom so that it complies with ADAAG 4.17.3, CBC 1115B
and CBC Figures 11B-1A and 1B. Standard accessible stalls
require 60 inches in width with 56 inches depth for wall-mounted Minimum Quantity 1
toilets or 59 inches depth for floor-mounted toilets to Maximum Quantity: 1
accommodate individuals in wheelchairs. The minimum width of
a front-approach doorway shall provide at least 32 inches and a Unit: Each
side-approach doorway shall provide at least 34 inches. The Minimum Estimated Cost: 4000
door shall swing outward, close automatically and provide
accessible hardware. Maximum Estimated Cost: 4000
Record Number 1045
Priority:

Restrooms
Finding: The height of the coat hook on the stall door designated to be
accessible in the restroom is greater than 48 inches above the
floor surface.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Horse Barn N

Full Rec Remount the coat hook on the stall door designated to be Citation CBC 1115B.9.2; ADAAG A4.27
accessible in the restroom to a maximum height of 48 inches
above the floor surface.
Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 1046
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 186 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: There are no grab bars in the stall designated to be accessible
in the restroom.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Horse Barn N

Full Rec Install one 36-inch back grab bar and one 42/48-inch side grab Citation CBC 1115B.8; ADAAG 4.26
bar in the stall designated to be accessible in the restroom.
Grab bars shall be mounted at a height of 33 inches above the
finished floor. Grab bars must be able to support a point load of Minimum Quantity 1
at least 250 pounds and shall be less than the allowable shear Maximum Quantity: 1
stress of the grab bar material.
Unit: Each
Minimum Estimated Cost: 531
Maximum Estimated Cost: 531
Record Number 1047
Priority:

Restrooms
Finding: The height of the toilet seat in the stall designated to be
accessible in the restroom is less than 17 inches above the
finished floor.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Horse Barn N

Full Rec Remove or modify the toilet in the stall designated to be Citation ADAAG 4.16.3
accessible in the restroom so that the seat height is between 17
inches and 19 inches above the finished floor (see ADAAG
4.16.3). Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1707
Maximum Estimated Cost: 1707
Record Number 1049
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 187 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The distance from the center of the toilet to the nearest side
wall in the stall designated to be accessible in the restroom is
less than 18 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Horse Barn N

Full Rec Relocate the toilet or stall side wall so that the distance from the Citation CBC 1115B.7.1.3 ADAAG 4.17.3
centerline of the toilet to the nearest side wall in the stall
designated to be accessible in the restroom is exactly 18 inches
(see ADAAG Figure 28. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1143
Maximum Estimated Cost: 1143
Record Number 1050
Priority:

Restrooms
Finding: The seat cover dispenser in the stall designated to be
accessible in the restroom is mounted at a height greater than
40 inches and there is no clear floor space.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Horse Barn N

Full Rec Relocate the seat cover dispenser in the stall designated to be Citation CBC 1115B.9.2
accessible in the restroom so that the height is no greater than
40 inches above the finished floor (see CBC 1115B.9.2). Make
certain that the location of the seat cover dispenser does not Minimum Quantity 1
interfere with the use of a grab bar and provides sufficient clear Maximum Quantity: 1
floor space.
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 1051
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 188 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The knee depth space under the lavatory designated to be
accessible in the restroom is less than 27 inches at 8 inches
under the lavatory apron.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Horse Barn N

Full Rec Raise or replace the lavatory designated to be accessible in the Citation ADAAG 4.19.2
restroom to provide at least 27 inches at 8 inches under the
apron. Make sure to provide at least 29 inches of clear knee
space between the finished floor and bottom of the lavatory Minimum Quantity 1
apron and a rim surface height no greater than 34 inches (see Maximum Quantity: 1
ADAAG 4.19.2).
Unit: Each
Minimum Estimated Cost: 1286
Maximum Estimated Cost: 1286
Record Number 1052
Priority:

Restrooms
Finding: The pipes under the lavatory in the restroom do not provide
protection against contact.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Horse Barn N

Full Rec Insulate or otherwise configure pipes under the lavatory Citation ADAAG 4.19.4
designated to be accessible in the restroom to protect against
contact (see ADAAG 4.19.4). Make certain there are no sharp
or abrasive surfaces under the lavatory. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 39
Maximum Estimated Cost: 39
Record Number 1053
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 189 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The bottom edge of the reflecting surface of the mirror in the
restroom is greater than 40 inches above the finished floor.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Horse Barn N

Full Rec Lower the mirror in the restroom so that the bottom edge of the Citation ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG
reflecting surface is no higher than 40 inches above the finished 4.19.6
floor and the topmost portion of the reflecting surface extends at
least 74 inches above the finished floor (see ADAAG A4.19.6). Minimum Quantity 1
A single, full-length mirror is recommended since it can Maximum Quantity: 1
accommodate all people. Make certain to provide a minimum
clear floor space in front of the mirror of 30 inches in width and Unit: Each
48 inches in length. Minimum Estimated Cost: 291
Maximum Estimated Cost: 291
Record Number 1054
Priority:

Restrooms
Finding: The height of the controls and operating mechanisms for the
soap dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Horse Barn N

Full Rec Relocate the soap dispenser in the restroom to a maximum Citation CBC 1115B.9.2; ADAAG A4.27
height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 1055
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 190 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the controls and operating mechanisms for the
paper towel dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Horse Barn N

Full Rec Relocate the paper towel dispenser in the restroom to a Citation CBC 1115B.9.2; ADAAG A4.27
maximum height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 1056
Priority:

Restrooms
Finding: The men's restroom provides two private shower stalls. There
are no accessible shower stalls provided in the men's restroom.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Horse Barn N

Full Rec Since shower stalls are provided in the restroom, at least one Citation CBC 1115B.6.2; ADAAG 4.21
accessible shower stall is required. Install an accessible shower
stall complying with CBC 1115B 6.2 and ADAAG 4.21 in the
men's restroom. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 2853
Maximum Estimated Cost: 2853
Record Number 1057
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 191 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The latch side approach to the shower stall designated to be
accessible in the restroom is less than 44 inches wide.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Horse Barn N

Full Rec Consult a design professional to provide a latch-side approach Citation CBC 1115B.7.1.3; ADAAG 4.17.3
to the shower stall designated to be accessible with a clear,
unobstructed access width of 44 inches with the space
immediately in front of the stall door at 48 inches in width. All Minimum Quantity 1
other approaches require 48 inches of clear, unobstructed Maximum Quantity: 1
access to and in front of the stall designated to be accessible in
the restroom. Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 1058
Priority:

Restrooms
Finding: There is less than 18 inches on the latch side of the entrance
door to the showers from the pull side.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Horse Barn N

Full Rec Consult a design professional to determine if it is technically Citation ADAAG 4.13.6; CBC 1133B.2.4.2
feasible to provide at least 18 inches of latch side clearance at
the entrance door to the restroom from the pull side (see
ADAAG 4.13.6 and Figure 25). Otherwise, an automatic door Minimum Quantity 1
opening device may be required to provide an accessible Maximum Quantity: 1
entrance.
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 1059
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 192 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: There is no signage indicating accessibility on the latch side of
the entry door of the restroom.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Horse Barn Q

Full Rec The restroom is designated accessible and should be made Citation CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7));
accessible for the facility. Post signage centered 60 inches ADAAG 4.1.6(3)(e); ADAAG 4.30
above the ground surface on the latch side of the entrance door
identifying the restroom as accessible upon completion of the Minimum Quantity 1
following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG Maximum Quantity: 1
4.1.6(3)(e). Signage shall include Braille and raised lettering,
the gender or unisex use symbol and the ISA symbol. Unit: Each
Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 1060
Priority:

Restrooms
Finding: The urinal in the restroom does not extend at least 14 inches
from the back wall. The height of the urinal rim is greater than
17 inches above the finished floor.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Horse Barn Q

Full Rec Replace the urinal designated to be accessible in the restroom Citation ADAAG 4.18.2
with a wall-mounted or stall-type tapered, elongated rim unit
complying with ADAAG 4.18.2. The height of the rim surface of
the urinal designated to be accessible shall not exceed 17 Minimum Quantity 1
inches above the finished floor and the flush control valve shall Maximum Quantity: 1
not exceed a height of 44 inches above the finished floor.
Unit: Each
Minimum Estimated Cost: 951
Maximum Estimated Cost: 951
Record Number 1061
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 193 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: There is insufficient clear floor space in the stall designated to
be accessible in the restroom. The stall door to the stall
designated to be accessible in the restroom swings inward
limiting the clear floor space in the stall designated to be
accessible. The door to the stall designated to be accessible in
the restroom does not close automatically or have accessible
hardware.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Horse Barn Q

Full Rec Modify or replace the stall designated to be accessible in the Citation CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
restroom so that it complies with ADAAG 4.17.3, CBC 1115B
and CBC Figures 11B-1A and 1B. Standard accessible stalls
require 60 inches in width with 56 inches depth for wall-mounted Minimum Quantity 1
toilets or 59 inches depth for floor-mounted toilets to Maximum Quantity: 1
accommodate individuals in wheelchairs. The minimum width of
a front-approach doorway shall provide at least 32 inches and a Unit: Each
side-approach doorway shall provide at least 34 inches. The Minimum Estimated Cost: 4000
door shall swing outward, close automatically and provide
accessible hardware. Maximum Estimated Cost: 4000
Record Number 1062
Priority:

Restrooms
Finding: The height of the coat hook on the stall door designated to be
accessible in the restroom is greater than 48 inches above the
floor surface.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Horse Barn Q

Full Rec Remount the coat hook on the stall door designated to be Citation CBC 1115B.9.2; ADAAG A4.27
accessible in the restroom to a maximum height of 48 inches
above the floor surface.
Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 1063
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 194 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: There are no grab bars in the stall designated to be accessible
in the restroom.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Horse Barn Q

Full Rec Install one 36-inch back grab bar and one 42/48-inch side grab Citation CBC 1115B.8; ADAAG 4.26
bar in the stall designated to be accessible in the restroom.
Grab bars shall be mounted at a height of 33 inches above the
finished floor. Grab bars must be able to support a point load of Minimum Quantity 1
at least 250 pounds and shall be less than the allowable shear Maximum Quantity: 1
stress of the grab bar material.
Unit: Each
Minimum Estimated Cost: 531
Maximum Estimated Cost: 531
Record Number 1064
Priority:

Restrooms
Finding: The height of the toilet seat in the stall designated to be
accessible in the restroom is less than 17 inches above the
finished floor.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Horse Barn Q

Full Rec Remove or modify the toilet in the stall designated to be Citation ADAAG 4.16.3
accessible in the restroom so that the seat height is between 17
inches and 19 inches above the finished floor (see ADAAG
4.16.3). Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1707
Maximum Estimated Cost: 1707
Record Number 1066
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 195 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The distance from the center of the toilet to the nearest side
wall in the stall designated to be accessible in the restroom is
less than 18 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Horse Barn Q

Full Rec Relocate the toilet or stall side wall so that the distance from the Citation CBC 1115B.7.1.3 ADAAG 4.17.3
centerline of the toilet to the nearest side wall in the stall
designated to be accessible in the restroom is exactly 18 inches
(see ADAAG Figure 28. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1143
Maximum Estimated Cost: 1143
Record Number 1067
Priority:

Restrooms
Finding: The seat cover dispenser in the stall designated to be
accessible in the restroom is mounted at a height greater than
40 inches and there is no clear floor space.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Horse Barn Q

Full Rec Relocate the seat cover dispenser in the stall designated to be Citation CBC 1115B.9.2
accessible in the restroom so that the height is no greater than
40 inches above the finished floor (see CBC 1115B.9.2). Make
certain that the location of the seat cover dispenser does not Minimum Quantity 1
interfere with the use of a grab bar and provides sufficient clear Maximum Quantity: 1
floor space.
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 1068
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 196 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The pipes under the lavatory in the restroom do not provide
protection against contact.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Horse Barn Q

Full Rec Insulate or otherwise configure pipes under the lavatory Citation ADAAG 4.19.4
designated to be accessible in the restroom to protect against
contact (see ADAAG 4.19.4). Make certain there are no sharp
or abrasive surfaces under the lavatory. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 39
Maximum Estimated Cost: 39
Record Number 1069
Priority:

Restrooms
Finding: The bottom edge of the reflecting surface of the mirror in the
restroom is greater than 40 inches above the finished floor.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Horse Barn Q

Full Rec Lower the mirror in the restroom so that the bottom edge of the Citation ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG
reflecting surface is no higher than 40 inches above the finished 4.19.6
floor and the topmost portion of the reflecting surface extends at
least 74 inches above the finished floor (see ADAAG A4.19.6). Minimum Quantity 1
A single, full-length mirror is recommended since it can Maximum Quantity: 1
accommodate all people. Make certain to provide a minimum
clear floor space in front of the mirror of 30 inches in width and Unit: Each
48 inches in length. Minimum Estimated Cost: 291
Maximum Estimated Cost: 291
Record Number 1070
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 197 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the controls and operating mechanisms for the
soap dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Horse Barn Q

Full Rec Relocate the soap dispenser in the restroom to a maximum Citation CBC 1115B.9.2; ADAAG A4.27
height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 1071
Priority:

Restrooms
Finding: The height of the controls and operating mechanisms for the
paper towel dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Horse Barn Q

Full Rec Relocate the paper towel dispenser in the restroom to a Citation CBC 1115B.9.2; ADAAG A4.27
maximum height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 1072
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 198 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The women's restroom provides two private shower stalls.
There are no accessible shower stalls provided in the women's
restroom.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Horse Barn Q

Full Rec Since shower stalls are provided in the restroom, at least one Citation CBC 1115B.6.2; ADAAG 4.21
accessible shower stall is required. Install an accessible shower
stall complying with CBC 1115B 6.2 and ADAAG 4.21 in the
women's restroom. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 2853
Maximum Estimated Cost: 2853
Record Number 1101
Priority:

Restrooms
Finding: The latch side approach to the shower stall designated to be
accessible in the restroom is less than 44 inches wide.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Horse Barn Q

Full Rec Consult a design professional to provide a latch-side approach Citation CBC 1115B.7.1.3; ADAAG 4.17.3
to the shower stall designated to be accessible with a clear,
unobstructed access width of 44 inches with the space
immediately in front of the stall door at 48 inches in width. All Minimum Quantity 1
other approaches require 48 inches of clear, unobstructed Maximum Quantity: 1
access to and in front of the stall designated to be accessible in
the restroom. Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 1102
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 199 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: There is less than 18 inches on the latch side of the entrance
door to the showers in the restroom from the pull side.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Horse Barn Q

Full Rec Consult a design professional to determine if it is technically Citation ADAAG 4.13.6; CBC 1133B.2.4.2
feasible to provide at least 18 inches of latch side clearance at
the entrance door to the restroom from the pull side (see
ADAAG 4.13.6 and Figure 25). Otherwise, an automatic door Minimum Quantity 1
opening device may be required to provide an accessible Maximum Quantity: 1
entrance.
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 1103
Priority:

Restrooms
Finding: There is no signage indicating accessibility on the latch side of
the entry door of the restroom. There is no Title 24 gender use
signage on the entrance door.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Livestock Building 1

Full Rec The restroom is designated accessible and should be made Citation CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7));
accessible for the facility. Post signage centered 60 inches ADAAG 4.1.6(3)(e); ADAAG 4.30
above the ground surface on the latch side of the entrance door
identifying the restroom as accessible upon completion of the Minimum Quantity 1
following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG Maximum Quantity: 1
4.1.6(3)(e). Signage shall include Braille and raised lettering,
the gender or unisex use symbol and the ISA symbol. Post Title Unit: Each
24 gender use signage on the door @ 60" o.c. a.f.f. Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 687
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 200 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The bottom 10 inches of the door does not provide a smooth,
uninterrupted surface, or panel to allow the door to be opened
by a wheelchair footrest without creating a trap or hazardous
condition, due to the door stop.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Livestock Building 1

Full Rec Install a panel or replace the door to provide a smooth, Citation CBC 1133B.2.6
uninterrupted surface for the bottom 10 inches of the door.

Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 688
Priority:

Restrooms
Finding: The door opening force for the exterior door is greater than 5
pounds of force.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Livestock Building 1

Full Rec Adjust the closers on all exterior doors to a maximum door Citation CBC 1133B.2.5; ADAAG 4.13.11
opening force of 5 pounds of force (see ADAAG 4.13.11 and
CBC 1133B.2.5).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 5
Maximum Estimated Cost: 5
Record Number 689
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 201 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: There is insufficient clear floor space in the stall designated to
be accessible in the restroom.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Livestock Building 1

Full Rec Modify or replace the stall designated to be accessible in the Citation CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
restroom so that it complies with ADAAG 4.17.3, CBC 1115B
and CBC Figures 11B-1A and 1B. Standard accessible stalls
require 60 inches in width with 56 inches depth for wall-mounted Minimum Quantity 1
toilets or 59 inches depth for floor-mounted toilets to Maximum Quantity: 1
accommodate individuals in wheelchairs. The minimum width of
a front-approach doorway shall provide at least 32 inches and a Unit: Each
side-approach doorway shall provide at least 34 inches. The Minimum Estimated Cost: 4000
door shall swing outward, close automatically and provide
accessible hardware. Maximum Estimated Cost: 4000
Record Number 690
Priority:

Restrooms
Finding: There is no back grab bar in the stall designated to be
accessible in the restroom.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Livestock Building 1

Full Rec Install a 36-inch back grab bar at a height of 33 inches above Citation CBC 1115B.8.1; ADAAG 4.26
the finished floor in the stall designated to be accessible of the
restroom. Grab bars must be able to support a point load of at
least 250 pounds and shall be less than the allowable shear Minimum Quantity 1
stress of the grab bar material. Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 531
Maximum Estimated Cost: 531
Record Number 691
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 202 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the side grab bars in the stall designated to be
accessible of the restroom is greater than 33 inches above the
finished floor.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Livestock Building 1

Full Rec Remount the side grab bars in the stall designated to be Citation CBC 1115B.8.1; ADAAG 4.26
accessible in the restroom so that the height of the gripping
surface is centered at 33 inches above finished floor. Grab bars
must be able to support a point load of at least 250 pounds and Minimum Quantity 1
shall be less than the allowable shear stress of the grab bar Maximum Quantity: 1
material.
Unit: Each
Minimum Estimated Cost: 448
Maximum Estimated Cost: 448
Record Number 692
Priority:

Restrooms
Finding: The distance from the end of the side grab bars to the back wall
in the stall designated to be accessible in the restroom is
greater than 12 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Livestock Building 1

Full Rec Remount the side grab bars in the stall designated to be Citation CBC 1115B.8.1; ADAAG 4.26
accessible in the restroom so that it is not more than 12 inches
from the back wall (see ADAAG Figure 29 and CBC 1115B.8).
Grab bars must be able to support a point load of at least 250 Minimum Quantity 1
pounds and shall be less than the allowable shear stress of the Maximum Quantity: 1
grab bar material.
Unit: Each
Minimum Estimated Cost: 448
Maximum Estimated Cost: 448
Record Number 693
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 203 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The flush control on the toilet in the stall designated to be
accessible in the restroom is not on the wide (approach) side of
the toilet.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Livestock Building 1

Full Rec Relocate the flush control on the toilet in the stall designated to Citation ADAAG 4.16.5; ADAAG 4.27.4
be accessible in the restroom so that it is on the wide
(approach) side of the toilet area (see ADAAG 4.16.5). Flush
controls shall be hand-operated or automatic mechanisms. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 127
Maximum Estimated Cost: 127
Record Number 694
Priority:

Restrooms
Finding: The distance from the center of the toilet to the nearest side
wall in the stall designated to be accessible in the restroom is
less than 18 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Livestock Building 1

Full Rec Relocate the toilet or stall side wall so that the distance from the Citation CBC 1115B.7.1.3 ADAAG 4.17.3
centerline of the toilet to the nearest side wall in the stall
designated to be accessible in the restroom is exactly 18 inches
(see ADAAG Figure 28. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1143
Maximum Estimated Cost: 1143
Record Number 695
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 204 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The seat cover dispenser in the stall designated to be
accessible in the restroom is mounted at a height greater than
40 inches and there is no clear floor space.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Livestock Building 1

Full Rec Relocate the seat cover dispenser in the stall designated to be Citation CBC 1115B.9.2
accessible in the restroom so that the height is no greater than
40 inches above the finished floor (see CBC 1115B.9.2). Make
certain that the location of the seat cover dispenser does not Minimum Quantity 1
interfere with the use of a grab bar and provides sufficient clear Maximum Quantity: 1
floor space.
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 696
Priority:

Restrooms
Finding: The pipes under the lavatory in the restroom do not provide
protection against contact.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Livestock Building 1

Full Rec Insulate or otherwise configure pipes under the lavatory Citation ADAAG 4.19.4
designated to be accessible in the restroom to protect against
contact (see ADAAG 4.19.4). Make certain there are no sharp
or abrasive surfaces under the lavatory. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 39
Maximum Estimated Cost: 39
Record Number 697
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 205 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the controls and operating mechanisms for the
soap dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Livestock Building 1

Full Rec Relocate the soap dispenser in the restroom to a maximum Citation CBC 1115B.9.2; ADAAG A4.27
height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 698
Priority:

Restrooms
Finding: The height of the controls and operating mechanisms for the
paper towel dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom at Livestock Building 1

Full Rec Relocate the paper towel dispenser in the restroom to a Citation CBC 1115B.9.2; ADAAG A4.27
maximum height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 699
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 206 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The signage indicating accessibility on the latch side of the
entry door of the restroom does not include Braille or raised
lettering and is not centered at 60 inches above the floor
surface. The gender use signage on the entrance door is not
centered at 60 inches above the floor surface.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the Carnival Area

Full Rec The restroom is designated accessible and should be made Citation CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7));
accessible for the facility. Post signage centered 60 inches ADAAG 4.1.6(3)(e); ADAAG 4.30
above the ground surface on the latch side of the entrance door
identifying the restroom as accessible upon completion of the Minimum Quantity 1
following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG Maximum Quantity: 1
4.1.6(3)(e). Signage shall include Braille and raised lettering,
the gender or unisex use symbol and the ISA symbol. Post Title Unit: Each
24 gender use signage on the door @ 60" o.c. a.f.f. Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 842
Priority:

Restrooms
Finding: The bottom 10 inches of the door does not provide a smooth,
uninterrupted surface, or panel to allow the door to be opened
by a wheelchair footrest without creating a trap or hazardous
condition, due to the door stop.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the Carnival Area

Full Rec Install a panel or replace the door to provide a smooth, Citation CBC 1133B.2.6
uninterrupted surface for the bottom 10 inches of the door.

Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 843
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 207 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the urinal rim in the restroom is greater than 17
inches above the finished floor.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the Carnival Area

Full Rec Lower the urinal designated to be accessible in the restroom so Citation ADAAG 4.18.2
that the rim height is not more than 17 inches above the finished
floor.
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1097
Maximum Estimated Cost: 1097
Record Number 844
Priority:

Restrooms
Finding: The height of the back grab bar in the stall designated to be
accessible of the restroom is less than 33 inches above the
finished floor.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the Carnival Area

Full Rec Remount the back grab bar in the stall designated to be Citation CBC 1115B.8.1; ADAAG 4.26
accessible in the restroom so that the height of the gripping
surface is centered at 33 inches above finished floor. Grab bars
must be able to support a point load of at least 250 pounds and Minimum Quantity 1
shall be less than the allowable shear stress of the grab bar Maximum Quantity: 1
material.
Unit: Each
Minimum Estimated Cost: 448
Maximum Estimated Cost: 448
Record Number 845
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 208 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The distance from the end of the back grab bar to the nearest
side wall in the stall designated to be accessible of the restroom
is greater than 6 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the Carnival Area

Full Rec Remount the back grab bar in the stall designated to be Citation ADAAG 4.26; CBC 1115B.8.1
accessible in the restroom so that it is not more than 6 inches
from the nearest side wall (see ADAAG 4.26 and CBC Figure
11B.1A-1C). Grab bars must be able to support a point load of Minimum Quantity 1
at least 250 pounds and shall be less than the allowable shear Maximum Quantity: 1
stress of the grab bar material.
Unit: Each
Minimum Estimated Cost: 448
Maximum Estimated Cost: 448
Record Number 846
Priority:

Restrooms
Finding: The distance from the end of the side grab bar to the back wall
in the stall designated to be accessible in the restroom is
greater than 12 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the Carnival Area

Full Rec Remount the side grab bar in the stall designated to be Citation CBC 1115B.8.1; ADAAG 4.26
accessible in the restroom so that it is not more than 12 inches
from the back wall (see ADAAG Figure 29 and CBC 1115B.8).
Grab bars must be able to support a point load of at least 250 Minimum Quantity 1
pounds and shall be less than the allowable shear stress of the Maximum Quantity: 1
grab bar material.
Unit: Each
Minimum Estimated Cost: 448
Maximum Estimated Cost: 448
Record Number 847
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 209 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The distance from the center of the toilet to the nearest side
wall in the stall designated to be accessible in the restroom is
greater than 18 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the Carnival Area

Full Rec Relocate the toilet or stall side wall so that the distance from the Citation CBC 1115B.7.1.3 ADAAG 4.17.3
centerline of the toilet to the nearest side wall in the stall
designated to be accessible in the restroom is exactly 18 inches
(see ADAAG Figure 28. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1143
Maximum Estimated Cost: 1143
Record Number 849
Priority:

Restrooms
Finding: The height of the controls and operating mechanisms for the
soap dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the Carnival Area

Full Rec Relocate the soap dispenser in the restroom to a maximum Citation CBC 1115B.9.2; ADAAG A4.27
height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 850
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 210 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the controls and operating mechanisms for the
paper towel dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the Carnival Area

Full Rec Relocate the paper towel dispenser in the restroom to a Citation CBC 1115B.9.2; ADAAG A4.27
maximum height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 851
Priority:

Restrooms
Finding: The signage on the latch side of the entry door of the restroom
does not include the International Symbol of Accessibility and is
not centered at 60 inches above the floor surface. There is no
Title 24 gender use signage on the entrance door.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the Delta Speedway (West End)

Full Rec The restroom is designated accessible and should be made Citation CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7));
accessible for the facility. Post signage centered 60 inches ADAAG 4.1.6(3)(e); ADAAG 4.30
above the ground surface on the latch side of the entrance door
identifying the restroom as accessible upon completion of the Minimum Quantity 1
following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG Maximum Quantity: 1
4.1.6(3)(e). Signage shall include Braille and raised lettering,
the gender or unisex use symbol and the ISA symbol. Post Title Unit: Each
24 gender use signage on the door @ 60" o.c. a.f.f. Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 1104
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 211 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: There are 12 stalls located in the multiple accommodation
restroom.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the Delta Speedway (West End)

Full Rec Create an accessible 36-inch wide alternate stall in addition to Citation CBC 1115B.7.1.4; ADAAG A4.17.3; ADAAG
the required accessible standard stall in the multiple 4.22.4
accommodation restroom. The accessible 36-inch wide
alternate stall shall include an outward swinging, self-closing Minimum Quantity 1
door and parallel side grab bars and shall provide at least 66 Maximum Quantity: 1
inches in length for a stall with a wall-mounted toilet or at least
69 inches in length for a stall with a floor-mounted toilet. Unit: Each
Minimum Estimated Cost: 4000
Maximum Estimated Cost: 4000
Record Number 1105
Priority:

Restrooms
Finding: The latch side approach to the stall designated to be accessible
in the restroom is less than 44 inches wide.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the Delta Speedway (West End)

Full Rec Consult a design professional to provide a latch-side approach Citation CBC 1115B.7.1.3; ADAAG 4.17.3
to the stall designated to be accessible with a clear,
unobstructed access width of 44 inches with the space
immediately in front of the stall door at 48 inches in width. All Minimum Quantity 1
other approaches require 48 inches of clear, unobstructed Maximum Quantity: 1
access to and in front of the stall designated to be accessible in
the restroom. Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 1106
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 212 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the coat hook on the stall door designated to be
accessible in the restroom is greater than 48 inches above the
floor surface.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the Delta Speedway (West End)

Full Rec Remount the coat hook on the stall door designated to be Citation CBC 1115B.9.2; ADAAG A4.27
accessible in the restroom to a maximum height of 48 inches
above the floor surface.
Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 1107
Priority:

Restrooms
Finding: The height of the side grab bar in the stall designated to be
accessible of the restroom is greater than 33 inches above the
finished floor.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the Delta Speedway (West End)

Full Rec Remount the side grab bar in the stall designated to be Citation CBC 1115B.8.1; ADAAG 4.26
accessible in the restroom so that the height of the gripping
surface is centered at 33 inches above finished floor. Grab bars
must be able to support a point load of at least 250 pounds and Minimum Quantity 1
shall be less than the allowable shear stress of the grab bar Maximum Quantity: 1
material.
Unit: Each
Minimum Estimated Cost: 448
Maximum Estimated Cost: 448
Record Number 1108
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 213 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The distance from the end of the back grab bar to the nearest
side wall in the stall designated to be accessible of the restroom
is greater than 6 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the Delta Speedway (West End)

Full Rec Remount the back grab bar in the stall designated to be Citation ADAAG 4.26; CBC 1115B.8.1
accessible in the restroom so that it is not more than 6 inches
from the nearest side wall (see ADAAG 4.26 and CBC Figure
11B.1A-1C). Grab bars must be able to support a point load of Minimum Quantity 1
at least 250 pounds and shall be less than the allowable shear Maximum Quantity: 1
stress of the grab bar material.
Unit: Each
Minimum Estimated Cost: 448
Maximum Estimated Cost: 448
Record Number 1109
Priority:

Restrooms
Finding: The side grab bar in the stall designated to be accessible in the
restroom does not extend 54 inches from the back wall.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the Delta Speedway (West End)

Full Rec The front end of the grab bar shall extend at least 54 inches Citation CBC 1115B.8.1; ADAAG 4.26
from the back wall and the back end of the grab bar shall be
mounted within 12 inches from the back wall. Grab bars must
be able to support a point load of at least 250 pounds and shall Minimum Quantity 1
be less than the allowable shear stress of the grab bar material. Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 531
Maximum Estimated Cost: 531
Record Number 1110
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 214 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The distance from the center of the toilet to the nearest side
wall in the stall designated to be accessible in the restroom is
less than 18 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the Delta Speedway (West End)

Full Rec Relocate the toilet or stall side wall so that the distance from the Citation CBC 1115B.7.1.3 ADAAG 4.17.3
centerline of the toilet to the nearest side wall in the stall
designated to be accessible in the restroom is exactly 18 inches
(see ADAAG Figure 28. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1143
Maximum Estimated Cost: 1143
Record Number 1112
Priority:

Restrooms
Finding: The seat cover dispenser in the stall designated to be
accessible in the restroom is mounted at a height greater than
40 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the Delta Speedway (West End)

Full Rec Relocate the seat cover dispenser in the stall designated to be Citation CBC 1115B.9.2
accessible in the restroom so that the height is no greater than
40 inches above the finished floor (see CBC 1115B.9.2). Make
certain that the location of the seat cover dispenser does not Minimum Quantity 1
interfere with the use of a grab bar and provides sufficient clear Maximum Quantity: 1
floor space.
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 1113
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 215 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The knee clearance space under the lavatory designated to be
accessible in the restroom is less than 29 inches. The knee
depth space under the lavatory designated to be accessible in
the restroom is less than 27 inches at 8 inches under the
lavatory apron.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the Delta Speedway (West End)

Full Rec Replace the lavatory designated to be accessible in the Citation ADAAG 4.19.2
restroom to provide at least 29 inches of clear knee space
between the finished floor and bottom of the lavatory apron.
Make sure to provide at least 27 inches at 8 inches under the Minimum Quantity 1
apron (see ADAAG 4.19.2). Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1286
Maximum Estimated Cost: 1286
Record Number 1114
Priority:

Restrooms
Finding: The pipes under the lavatory in the restroom do not provide
protection against contact.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the Delta Speedway (West End)

Full Rec Insulate or otherwise configure pipes under the lavatory Citation ADAAG 4.19.4
designated to be accessible in the restroom to protect against
contact (see ADAAG 4.19.4). Make certain there are no sharp
or abrasive surfaces under the lavatory. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 39
Maximum Estimated Cost: 39
Record Number 1115
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 216 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the controls and operating mechanisms for the
soap dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the Delta Speedway (West End)

Full Rec Relocate the soap dispenser in the restroom to a maximum Citation CBC 1115B.9.2; ADAAG A4.27
height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 1116
Priority:

Restrooms
Finding: The height of the controls and operating mechanisms for the
paper towel dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the Delta Speedway (West End)

Full Rec Relocate the paper towel dispenser in the restroom to a Citation CBC 1115B.9.2; ADAAG A4.27
maximum height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 1117
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 217 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the controls and operating mechanisms for the
hand dryer in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the Delta Speedway (West End)

Full Rec Relocate the hand dryer in the restroom to a maximum height of Citation CBC 1115B.9.2; ADAAG A4.27
40 inches for all the controls and operating mechanisms (see
CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 1118
Priority:

Restrooms
Finding: There is no Title 24 gender use signage on the entrance door.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the Grandstands (East End)

Full Rec The restroom is designated accessible and should be made Citation CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7));
accessible for the facility. Post Title 24 gender use signage on ADAAG 4.1.6(3)(e); ADAAG 4.30
the door @ 60" o.c. a.f.f.
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 862
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 218 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: There is less than 18 inches on the latch side of the entrance
door to the restroom from the pull side.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the Grandstands (East End)

Full Rec Consult a design professional to determine if it is technically Citation ADAAG 4.13.6; CBC 1133B.2.4.2
feasible to provide at least 18 inches of latch side clearance at
the entrance door to the restroom from the pull side (see
ADAAG 4.13.6 and Figure 25). Otherwise, an automatic door Minimum Quantity 1
opening device may be required to provide an accessible Maximum Quantity: 1
entrance.
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 863
Priority:

Restrooms
Finding: The bottom 10 inches of the door does not provide a smooth,
uninterrupted surface, or panel to allow the door to be opened
by a wheelchair footrest without creating a trap or hazardous
condition, due to the door stop.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the Grandstands (East End)

Full Rec Install a panel or replace the door to provide a smooth, Citation CBC 1133B.2.6
uninterrupted surface for the bottom 10 inches of the door.

Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 864
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 219 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the urinal rim in the restroom is greater than 17
inches above the finished floor.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the Grandstands (East End)

Full Rec Lower the urinal designated to be accessible in the restroom so Citation ADAAG 4.18.2
that the rim height is not more than 17 inches above the finished
floor.
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1097
Maximum Estimated Cost: 1097
Record Number 865
Priority:

Restrooms
Finding: There is insufficient clear floor space in the stall designated to
be accessible in the restroom. The inside handle on the stall
door is not mounted immediately below the latch.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the Grandstands (East End)

Full Rec Modify or replace the stall designated to be accessible in the Citation CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
restroom so that it complies with ADAAG 4.17.3, CBC 1115B
and CBC Figures 11B-1A and 1B. Standard accessible stalls
require 60 inches in width with 56 inches depth for wall-mounted Minimum Quantity 1
toilets or 59 inches depth for floor-mounted toilets to Maximum Quantity: 1
accommodate individuals in wheelchairs. The minimum width of
a front-approach doorway shall provide at least 32 inches and a Unit: Each
side-approach doorway shall provide at least 34 inches. The Minimum Estimated Cost: 4000
door shall swing outward, close automatically and provide
accessible hardware. Maximum Estimated Cost: 4000
Record Number 866
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 220 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the coat hook on the stall door designated to be
accessible in the restroom is greater than 48 inches above the
floor surface.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the Grandstands (East End)

Full Rec Remount the coat hook on the stall door designated to be Citation CBC 1115B.9.2; ADAAG A4.27
accessible in the restroom to a maximum height of 48 inches
above the floor surface.
Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 867
Priority:

Restrooms
Finding: There is no back grab bar in the stall designated to be
accessible in the restroom.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the Grandstands (East End)

Full Rec Install a 36-inch back grab bar at a height of 33 inches above Citation CBC 1115B.8.1; ADAAG 4.26
the finished floor in the stall designated to be accessible of the
restroom. Grab bars must be able to support a point load of at
least 250 pounds and shall be less than the allowable shear Minimum Quantity 1
stress of the grab bar material. Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 531
Maximum Estimated Cost: 531
Record Number 868
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 221 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the right grab bar in the stall designated to be
accessible of the restroom is less than 33 inches above the
finished floor.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the Grandstands (East End)

Full Rec Remount the right grab bar in the stall designated to be Citation CBC 1115B.8.1; ADAAG 4.26
accessible in the restroom so that the height of the gripping
surface is centered at 33 inches above finished floor. Grab bars
must be able to support a point load of at least 250 pounds and Minimum Quantity 1
shall be less than the allowable shear stress of the grab bar Maximum Quantity: 1
material.
Unit: Each
Minimum Estimated Cost: 448
Maximum Estimated Cost: 448
Record Number 869
Priority:

Restrooms
Finding: The location of the toilet paper dispenser in the stall designated
to be accessible in the restroom is not within 12 inches of the
front edge of the toilet seat. The toilet paper dispenser
protrudes more than 4 inches from the side wall and interferes
with the clear floor space of the water closet.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the Grandstands (East End)

Full Rec Remount the toilet paper dispenser in the stall designated to be Citation CBC 1115B.9.3; ADAAG 4.16.6
accessible in the restroom so that it is within 12 inches from the
front edge of the toilet seat and does not encroach more than
four inches from the face of the wall (see CBC 1115B.9.3 and Minimum Quantity 1
ADAAG Figure 29(b)). Toilet paper dispensers must allow Maximum Quantity: 1
continuous paper flow and shall not interfere with the use of the
side grab bar. Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 870
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 222 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The flush control on the toilet in the stall designated to be
accessible in the restroom is not on the wide (approach) side of
the toilet.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the Grandstands (East End)

Full Rec Relocate the flush control on the toilet in the stall designated to Citation ADAAG 4.16.5; ADAAG 4.27.4
be accessible in the restroom so that it is on the wide
(approach) side of the toilet area (see ADAAG 4.16.5). Flush
controls shall be hand-operated or automatic mechanisms. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 127
Maximum Estimated Cost: 127
Record Number 871
Priority:

Restrooms
Finding: The distance from the center of the toilet to the nearest side
wall in the stall designated to be accessible in the restroom is
less than 18 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the Grandstands (East End)

Full Rec Relocate the toilet or stall side wall so that the distance from the Citation CBC 1115B.7.1.3 ADAAG 4.17.3
centerline of the toilet to the nearest side wall in the stall
designated to be accessible in the restroom is exactly 18 inches
(see ADAAG Figure 28. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1143
Maximum Estimated Cost: 1143
Record Number 872
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 223 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The knee depth space under the lavatory designated to be
accessible in the restroom is less than 27 inches at 8 inches
under the lavatory apron.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the Grandstands (East End)

Full Rec Raise or replace the lavatory designated to be accessible in the Citation ADAAG 4.19.2
restroom to provide at least 27 inches at 8 inches under the
apron. Make sure to provide at least 29 inches of clear knee
space between the finished floor and bottom of the lavatory Minimum Quantity 1
apron and a rim surface height no greater than 34 inches (see Maximum Quantity: 1
ADAAG 4.19.2).
Unit: Each
Minimum Estimated Cost: 1286
Maximum Estimated Cost: 1286
Record Number 873
Priority:

Restrooms
Finding: The height of the controls and operating mechanisms for the
soap dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the Grandstands (East End)

Full Rec Relocate the soap dispenser in the restroom to a maximum Citation CBC 1115B.9.2; ADAAG A4.27
height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 874
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 224 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the controls and operating mechanisms for the
paper towel dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the Grandstands (East End)

Full Rec Relocate the paper towel dispenser in the restroom to a Citation CBC 1115B.9.2; ADAAG A4.27
maximum height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 875
Priority:

Restrooms
Finding: There is no Title 24 gender use signage on the entrance door.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the Grandstands (North End)

Full Rec The restroom is designated accessible and should be made Citation CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7));
accessible for the facility Post Title 24 gender use signage on ADAAG 4.1.6(3)(e); ADAAG 4.30
the door @ 60" o.c. a.f.f.
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 876
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 225 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: There is less than 24 inches of clearance on the latch side of
the exterior entrance door.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the Grandstands (North End)

Full Rec Consult a design professional to determine if it is technically Citation ADAAG 4.13.6
feasible to provide at least 24 inches of latch side clearance at
the entrance door (see ADAAG 4.13.6 and Figure 25).
Otherwise, install an automatic door opening device to the Minimum Quantity 1
primary entrance complying with ADAAG 4.13.12 and Maximum Quantity: 1
ANSI/BHMA A156.10, 1985, standards.
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 877
Priority:

Restrooms
Finding: The bottom 10 inches of the door does not provide a smooth,
uninterrupted surface, or panel to allow the door to be opened
by a wheelchair footrest without creating a trap or hazardous
condition, due to the door stop.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the Grandstands (North End)

Full Rec Install a panel or replace the door to provide a smooth, Citation CBC 1133B.2.6
uninterrupted surface for the bottom 10 inches of the door.

Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 878
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 226 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: There is no level landing provided at the entrance door.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the Grandstands (North End)

Full Rec Provide a level and clear landing at least 60 inches in length in Citation CBC 1133B.2.4.2; ADAAG 4.13.6
the direction of the door swing.

Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 879
Priority:

Restrooms
Finding: The urinal in the restroom does not extend at least 14 inches
from the back wall. The flush control valve on the urinal is
greater than 44 inches above the finished floor.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the Grandstands (North End)

Full Rec Replace the urinal designated to be accessible in the restroom Citation ADAAG 4.18.2
with a wall-mounted or stall-type tapered, elongated rim unit
complying with ADAAG 4.18.2. The height of the rim surface of
the urinal designated to be accessible shall not exceed 17 Minimum Quantity 1
inches above the finished floor and the flush control valve shall Maximum Quantity: 1
not exceed a height of 44 inches above the finished floor.
Unit: Each
Minimum Estimated Cost: 951
Maximum Estimated Cost: 951
Record Number 880
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 227 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The length of the back grab bar in the stall designated to be
accessible of the restroom is less than 36 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the Grandstands (North End)

Full Rec Replace the back grab bar in the stall designated to be Citation CBC 1115B.8.1; ADAAG 4.26
accessible of the restroom with a 36-inch back grab bar
complying with ADAAG 4.26 and CBC 1115B.8. Grab bars
must be able to support a point load of at least 250 pounds and Minimum Quantity 1
shall be less than the allowable shear stress of the grab bar Maximum Quantity: 1
material.
Unit: Each
Minimum Estimated Cost: 531
Maximum Estimated Cost: 531
Record Number 881
Priority:

Restrooms
Finding: The height of the side grab bar in the stall designated to be
accessible of the restroom is greater than 33 inches above the
finished floor.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the Grandstands (North End)

Full Rec Remount the side grab bar in the stall designated to be Citation CBC 1115B.8.1; ADAAG 4.26
accessible in the restroom so that the height of the gripping
surface is centered at 33 inches above finished floor. Grab bars
must be able to support a point load of at least 250 pounds and Minimum Quantity 1
shall be less than the allowable shear stress of the grab bar Maximum Quantity: 1
material.
Unit: Each
Minimum Estimated Cost: 448
Maximum Estimated Cost: 448
Record Number 882
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 228 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The location of the toilet paper dispenser in the stall designated
to be accessible in the restroom is not within 12 inches of the
front edge of the toilet seat. The toilet paper dispenser
protrudes more than 4 inches from the side wall and interferes
with the clear floor space of the water closet.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the Grandstands (North End)

Full Rec Remount the toilet paper dispenser in the stall designated to be Citation CBC 1115B.9.3; ADAAG 4.16.6
accessible in the restroom so that it is within 12 inches from the
front edge of the toilet seat and does not encroach more than
four inches from the face of the wall (see CBC 1115B.9.3 and Minimum Quantity 1
ADAAG Figure 29(b)). Toilet paper dispensers must allow Maximum Quantity: 1
continuous paper flow and shall not interfere with the use of the
side grab bar. Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 883
Priority:

Restrooms
Finding: The flush control on the toilet in the stall designated to be
accessible in the restroom is not on the wide (approach) side of
the toilet.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the Grandstands (North End)

Full Rec Relocate the flush control on the toilet in the stall designated to Citation ADAAG 4.16.5; ADAAG 4.27.4
be accessible in the restroom so that it is on the wide
(approach) side of the toilet area (see ADAAG 4.16.5). Flush
controls shall be hand-operated or automatic mechanisms. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 127
Maximum Estimated Cost: 127
Record Number 884
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 229 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The distance from the center of the toilet to the nearest side
wall in the stall designated to be accessible in the restroom is
greater than 18 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the Grandstands (North End)

Full Rec Relocate the toilet or stall side wall so that the distance from the Citation CBC 1115B.7.1.3 ADAAG 4.17.3
centerline of the toilet to the nearest side wall in the stall
designated to be accessible in the restroom is exactly 18 inches
(see ADAAG Figure 28. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1143
Maximum Estimated Cost: 1143
Record Number 885
Priority:

Restrooms
Finding: The bottom edge of the reflecting surface of the mirror in the
restroom is greater than 40 inches above the finished floor.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the Grandstands (North End)

Full Rec Lower the mirror in the restroom so that the bottom edge of the Citation ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG
reflecting surface is no higher than 40 inches above the finished 4.19.6
floor and the topmost portion of the reflecting surface extends at
least 74 inches above the finished floor (see ADAAG A4.19.6). Minimum Quantity 1
A single, full-length mirror is recommended since it can Maximum Quantity: 1
accommodate all people. Make certain to provide a minimum
clear floor space in front of the mirror of 30 inches in width and Unit: Each
48 inches in length. Minimum Estimated Cost: 291
Maximum Estimated Cost: 291
Record Number 886
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 230 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the controls and operating mechanisms for the
paper towel dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the Grandstands (North End)

Full Rec Relocate the paper towel dispenser in the restroom to a Citation CBC 1115B.9.2; ADAAG A4.27
maximum height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 887
Priority:

Restrooms
Finding: There is no signage indicating accessibility on the latch side of
the entry door of the restroom. The gender use signage on the
entrance door is not centered at 60 inches above the floor
surface and does not include the ISA symbol.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the Maintenance Facility

Full Rec The restroom is designated accessible and should be made Citation CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7));
accessible for the facility. Post signage centered 60 inches ADAAG 4.1.6(3)(e); ADAAG 4.30
above the ground surface on the latch side of the entrance door
identifying the restroom as accessible upon completion of the Minimum Quantity 1
following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG Maximum Quantity: 1
4.1.6(3)(e). Signage shall include Braille and raised lettering,
the gender or unisex use symbol and the ISA symbol. Post Title Unit: Each
24 gender use signage on the door @ 60" o.c. a.f.f. Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 1084
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 231 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The bottom 10 inches of the door does not provide a smooth,
uninterrupted surface, or panel to allow the door to be opened
by a wheelchair footrest without creating a trap or hazardous
condition, due to the doorstop.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the Maintenance Facility

Full Rec Install a panel or replace the door to provide a smooth, Citation CBC 1133B.2.6
uninterrupted surface for the bottom 10 inches of the door.

Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 1085
Priority:

Restrooms
Finding: The clear opening width of the entrance doorway to the
restroom is less than 32 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the Maintenance Facility

Full Rec Widen the entrance doorway to the restroom to provide a clear Citation ADAAG 4.13.5
opening width of at least 32 inches when the door is open 90
degrees (see ADAAG 4.13.5).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 750
Maximum Estimated Cost: 750
Record Number 1086
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 232 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The entrance door to the restroom has a round doorknob that
requires tight grasping or twisting of the wrist to operate.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the Maintenance Facility

Full Rec Replace the door hardware mounted on the restroom complying Citation ADAAG 4.13.9
with ADAAG 4.13.9. Make certain accessible door hardware is
mounted no higher than 48 inches above the finished floor.
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 204
Maximum Estimated Cost: 204
Record Number 1087
Priority:

Restrooms
Finding: There is less than 18 inches on the latch side of the entrance
door to the restroom from the pull side.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the Maintenance Facility

Full Rec Consult a design professional to determine if it is technically Citation ADAAG 4.13.6; CBC 1133B.2.4.2
feasible to provide at least 18 inches of latch side clearance at
the entrance door to the restroom from the pull side (see
ADAAG 4.13.6 and Figure 25). Otherwise, an automatic door Minimum Quantity 1
opening device may be required to provide an accessible Maximum Quantity: 1
entrance.
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 1088
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 233 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The urinal in the restroom does not extend at least 14 inches
from the back wall.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the Maintenance Facility

Full Rec Replace the urinal designated to be accessible in the restroom Citation ADAAG 4.18.2
with a wall-mounted or stall-type tapered, elongated rim unit
complying with ADAAG 4.18.2. The height of the rim surface of
the urinal designated to be accessible shall not exceed 17 Minimum Quantity 1
inches above the finished floor and the flush control valve shall Maximum Quantity: 1
not exceed a height of 44 inches above the finished floor.
Unit: Each
Minimum Estimated Cost: 951
Maximum Estimated Cost: 951
Record Number 1089
Priority:

Restrooms
Finding: There is insufficient clear floor space in the stall designated to
be accessible in the restroom. The stall door to the stall
designated to be accessible in the restroom swings inward
limiting the clear floor space in the stall designated to be
accessible. The door to the stall designated to be accessible in
the restroom does not close automatically or have accessible
hardware.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the Maintenance Facility

Full Rec Modify or replace the stall designated to be accessible in the Citation CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
restroom so that it complies with ADAAG 4.17.3, CBC 1115B
and CBC Figures 11B-1A and 1B. Standard accessible stalls
require 60 inches in width with 56 inches depth for wall-mounted Minimum Quantity 1
toilets or 59 inches depth for floor-mounted toilets to Maximum Quantity: 1
accommodate individuals in wheelchairs. The minimum width of
a front-approach doorway shall provide at least 32 inches and a Unit: Each
side-approach doorway shall provide at least 34 inches. The Minimum Estimated Cost: 4000
door shall swing outward, close automatically and provide
accessible hardware. Maximum Estimated Cost: 4000
Record Number 1090
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 234 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: There are no grab bars in the stall designated to be accessible
in the restroom.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the Maintenance Facility

Full Rec Install one 36-inch back grab bar and one 42/48-inch side grab Citation CBC 1115B.8; ADAAG 4.26
bar in the stall designated to be accessible in the restroom.
Grab bars shall be mounted at a height of 33 inches above the
finished floor. Grab bars must be able to support a point load of Minimum Quantity 1
at least 250 pounds and shall be less than the allowable shear Maximum Quantity: 1
stress of the grab bar material.
Unit: Each
Minimum Estimated Cost: 531
Maximum Estimated Cost: 531
Record Number 1091
Priority:

Restrooms
Finding: The height of the toilet seat in the stall designated to be
accessible in the restroom is less than 17 inches above the
finished floor.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the Maintenance Facility

Full Rec Remove or modify the toilet in the stall designated to be Citation ADAAG 4.16.3
accessible in the restroom so that the seat height is between 17
inches and 19 inches above the finished floor (see ADAAG
4.16.3). Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1707
Maximum Estimated Cost: 1707
Record Number 1093
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 235 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The distance from the center of the toilet to the nearest side
wall in the stall designated to be accessible in the restroom is
less than 18 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the Maintenance Facility

Full Rec Relocate the toilet or stall side wall so that the distance from the Citation CBC 1115B.7.1.3 ADAAG 4.17.3
centerline of the toilet to the nearest side wall in the stall
designated to be accessible in the restroom is exactly 18 inches
(see ADAAG Figure 28. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1143
Maximum Estimated Cost: 1143
Record Number 1094
Priority:

Restrooms
Finding: The seat cover dispenser in the stall designated to be
accessible in the restroom is mounted at a height greater than
40 inches and there is no clear floor space.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the Maintenance Facility

Full Rec Relocate the seat cover dispenser in the stall designated to be Citation CBC 1115B.9.2
accessible in the restroom so that the height is no greater than
40 inches above the finished floor (see CBC 1115B.9.2). Make
certain that the location of the seat cover dispenser does not Minimum Quantity 1
interfere with the use of a grab bar and provides sufficient clear Maximum Quantity: 1
floor space.
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 1095
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 236 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The knee clearance space under the lavatory designated to be
accessible in the restroom is less than 29 inches. The knee
depth space under the lavatory designated to be accessible in
the restroom is less than 27 inches at 8 inches under the
lavatory apron.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the Maintenance Facility

Full Rec Replace the lavatory designated to be accessible in the Citation ADAAG 4.19.2
restroom to provide at least 29 inches of clear knee space
between the finished floor and bottom of the lavatory apron.
Make sure to provide at least 27 inches at 8 inches under the Minimum Quantity 1
apron (see ADAAG 4.19.2). Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1286
Maximum Estimated Cost: 1286
Record Number 1096
Priority:

Restrooms
Finding: The pipes under the lavatory in the restroom do not provide
protection against contact.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the Maintenance Facility

Full Rec Insulate or otherwise configure pipes under the lavatory Citation ADAAG 4.19.4
designated to be accessible in the restroom to protect against
contact (see ADAAG 4.19.4). Make certain there are no sharp
or abrasive surfaces under the lavatory. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 39
Maximum Estimated Cost: 39
Record Number 1097
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 237 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The bottom edge of the reflecting surface of the mirror in the
restroom is greater than 40 inches above the finished floor.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the Maintenance Facility

Full Rec Lower the mirror in the restroom so that the bottom edge of the Citation ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG
reflecting surface is no higher than 40 inches above the finished 4.19.6
floor and the topmost portion of the reflecting surface extends at
least 74 inches above the finished floor (see ADAAG A4.19.6). Minimum Quantity 1
A single, full-length mirror is recommended since it can Maximum Quantity: 1
accommodate all people. Make certain to provide a minimum
clear floor space in front of the mirror of 30 inches in width and Unit: Each
48 inches in length. Minimum Estimated Cost: 291
Maximum Estimated Cost: 291
Record Number 1098
Priority:

Restrooms
Finding: The height of the controls and operating mechanisms for the
soap dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the Maintenance Facility

Full Rec Relocate the soap dispenser in the restroom to a maximum Citation CBC 1115B.9.2; ADAAG A4.27
height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 1099
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 238 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the controls and operating mechanisms for the
paper towel dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the Maintenance Facility

Full Rec Relocate the paper towel dispenser in the restroom to a Citation CBC 1115B.9.2; ADAAG A4.27
maximum height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 1100
Priority:

Restrooms
Finding: The signage on the latch side of the entry door of the restroom
does not include the International Symbol of Accessibility.
There is no Title 24 gender use signage on the entrance door.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the RV Park

Full Rec The restroom is designated accessible and should be made Citation CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7));
accessible for the facility. Post signage centered 60 inches ADAAG 4.1.6(3)(e); ADAAG 4.30
above the ground surface on the latch side of the entrance door
identifying the restroom as accessible upon completion of the Minimum Quantity 1
following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG Maximum Quantity: 1
4.1.6(3)(e). Signage shall include Braille and raised lettering,
the gender or unisex use symbol and the ISA symbol. Post Title Unit: Each
24 gender use signage on the door @ 60" o.c. a.f.f. Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 583
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 239 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The door opening force for the exterior door is greater than 5
pounds of force.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the RV Park

Full Rec Adjust the closers on all exterior doors to a maximum door Citation CBC 1133B.2.5; ADAAG 4.13.11
opening force of 5 pounds of force (see ADAAG 4.13.11 and
CBC 1133B.2.5).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 5
Maximum Estimated Cost: 5
Record Number 584
Priority:

Restrooms
Finding: The height of the side and back grab bar in the stall designated
to be accessible of the restroom is less than 33 inches above
the finished floor.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the RV Park

Full Rec Remount the side and back grab bar in the stall designated to Citation CBC 1115B.8.1; ADAAG 4.26
be accessible in the restroom so that the height of the gripping
surface is centered at 33 inches above finished floor. Grab bars
must be able to support a point load of at least 250 pounds and Minimum Quantity 1
shall be less than the allowable shear stress of the grab bar Maximum Quantity: 1
material.
Unit: Each
Minimum Estimated Cost: 448
Maximum Estimated Cost: 448
Record Number 585
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 240 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The distance from the end of the back grab bar to the nearest
side wall in the stall designated to be accessible of the restroom
is greater than 6 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the RV Park

Full Rec Remount the back grab bar in the stall designated to be Citation ADAAG 4.26; CBC 1115B.8.1
accessible in the restroom so that it is not more than 6 inches
from the nearest side wall (see ADAAG 4.26 and CBC Figure
11B.1A-1C). Grab bars must be able to support a point load of Minimum Quantity 1
at least 250 pounds and shall be less than the allowable shear Maximum Quantity: 1
stress of the grab bar material.
Unit: Each
Minimum Estimated Cost: 448
Maximum Estimated Cost: 448
Record Number 586
Priority:

Restrooms
Finding: The distance from the center of the toilet to the nearest side
wall in the stall designated to be accessible in the restroom is
greater than 18 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the RV Park

Full Rec Relocate the toilet or stall side wall so that the distance from the Citation CBC 1115B.7.1.3 ADAAG 4.17.3
centerline of the toilet to the nearest side wall in the stall
designated to be accessible in the restroom is exactly 18 inches
(see ADAAG Figure 28. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1143
Maximum Estimated Cost: 1143
Record Number 587
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 241 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the controls and operating mechanisms for the
paper towel dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the RV Park

Full Rec Relocate the paper towel dispenser in the restroom to a Citation CBC 1115B.9.2; ADAAG A4.27
maximum height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 588
Priority:

Restrooms
Finding: There is signage indicating accessibility on the entry door to the
restroom. The signage is centered 60 inches above the floor on
the latch side of the entrance door and includes Braille and
raised lettering, gender use symbol and the ISA symbol.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the Winner's Gaming and Sports


Emporium

Full Rec The restroom is designated accessible and should be made an Citation CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7));
accessible restroom for the facility. Monitor signage for ADAAG 4.1.6(3)(e); ADAAG 4.30
continued compliance with CBC 1115B.5, ADAAG 4.1.2(7) and
ADAAG 4.1.6(3)(e)) and ADAAG 4.30. Minimum Quantity 1
Maximum Quantity: 1
Unit: None Selected
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 1127
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 242 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The urinal in the restroom does not extend at least 14 inches
from the back wall.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the Winner's Gaming and Sports


Emporium

Full Rec Replace the urinal designated to be accessible in the restroom Citation ADAAG 4.18.2
with a wall-mounted or stall-type tapered, elongated rim unit
complying with ADAAG 4.18.2. The height of the rim surface of
the urinal designated to be accessible shall not exceed 17 Minimum Quantity 1
inches above the finished floor and the flush control valve shall Maximum Quantity: 1
not exceed a height of 44 inches above the finished floor.
Unit: Each
Minimum Estimated Cost: 951
Maximum Estimated Cost: 951
Record Number 1128
Priority:

Restrooms
Finding: There is insufficient clear floor space in the stall designated to
be accessible in the restroom. The door to the stall designated
to be accessible in the restroom does not have accessible
hardware.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the Winner's Gaming and Sports


Emporium

Full Rec Modify or replace the stall designated to be accessible in the Citation CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
restroom so that it complies with ADAAG 4.17.3, CBC 1115B
and CBC Figures 11B-1A and 1B. Standard accessible stalls
require 60 inches in width with 56 inches depth for wall-mounted Minimum Quantity 1
toilets or 59 inches depth for floor-mounted toilets to Maximum Quantity: 1
accommodate individuals in wheelchairs. The minimum width of
a front-approach doorway shall provide at least 32 inches and a Unit: Each
side-approach doorway shall provide at least 34 inches. The Minimum Estimated Cost: 4000
door shall swing outward, close automatically and provide
accessible hardware. Maximum Estimated Cost: 4000
Record Number 1129
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 243 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The distance from the center of the toilet to the nearest side
wall in the stall designated to be accessible in the restroom is
less than 18 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the Winner's Gaming and Sports


Emporium

Full Rec Relocate the toilet or stall side wall so that the distance from the Citation CBC 1115B.7.1.3 ADAAG 4.17.3
centerline of the toilet to the nearest side wall in the stall
designated to be accessible in the restroom is exactly 18 inches
(see ADAAG Figure 28. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1143
Maximum Estimated Cost: 1143
Record Number 1130
Priority:

Restrooms
Finding: The seat cover dispenser in the stall designated to be
accessible in the restroom is mounted at a height greater than
40 inches and there is no clear floor space.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the Winner's Gaming and Sports


Emporium

Full Rec Relocate the seat cover dispenser in the stall designated to be Citation CBC 1115B.9.2
accessible in the restroom so that the height is no greater than
40 inches above the finished floor (see CBC 1115B.9.2). Make
certain that the location of the seat cover dispenser does not Minimum Quantity 1
interfere with the use of a grab bar and provides sufficient clear Maximum Quantity: 1
floor space.
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 1131
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 244 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The knee depth space under the lavatory designated to be
accessible in the restroom is less than 27 inches at 8 inches
under the lavatory apron.

Alternative *
Rec:
(Where
Available)

Men's Restroom at the Winner's Gaming and Sports


Emporium

Full Rec Raise or replace the lavatory designated to be accessible in the Citation ADAAG 4.19.2
restroom to provide at least 27 inches at 8 inches under the
apron. Make sure to provide at least 29 inches of clear knee
space between the finished floor and bottom of the lavatory Minimum Quantity 1
apron and a rim surface height no greater than 34 inches (see Maximum Quantity: 1
ADAAG 4.19.2).
Unit: Each
Minimum Estimated Cost: 1286
Maximum Estimated Cost: 1286
Record Number 1132
Priority:

Restrooms
Finding: There is no signage indicating accessibility on the latch side of
the entry door of the restroom. There is no Title 24 gender use
signage on the entrance door.

Alternative *
Rec:
(Where
Available)

Men's Restroom in Building 3

Full Rec The restroom is designated accessible and should be made Citation CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7));
accessible for the facility. Post signage centered 60 inches ADAAG 4.1.6(3)(e); ADAAG 4.30
above the ground surface on the latch side of the entrance door
identifying the restroom as accessible upon completion of the Minimum Quantity 1
following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG Maximum Quantity: 1
4.1.6(3)(e). Signage shall include Braille and raised lettering,
the gender or unisex use symbol and the ISA symbol. Post Title Unit: Each
24 gender use signage on the door @ 60" o.c. a.f.f. Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 494
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 245 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The clear opening width of the entrance doorway to the
restroom is less than 32 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom in Building 3

Full Rec Widen the entrance doorway to the restroom to provide a clear Citation ADAAG 4.13.5
opening width of at least 32 inches when the door is open 90
degrees (see ADAAG 4.13.5).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 750
Maximum Estimated Cost: 750
Record Number 495
Priority:

Restrooms
Finding: The entrance door to the restroom has a round doorknob that
requires tight grasping or twisting of the wrist to operate.

Alternative *
Rec:
(Where
Available)

Men's Restroom in Building 3

Full Rec Replace the door hardware mounted on the restroom complying Citation ADAAG 4.13.9
with ADAAG 4.13.9. Make certain accessible door hardware is
mounted no higher than 48 inches above the finished floor.
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 204
Maximum Estimated Cost: 204
Record Number 496
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 246 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The bottom 10 inches of the door does not provide a smooth,
uninterrupted surface, or panel to allow the door to be opened
by a wheelchair footrest without creating a trap or hazardous
condition, due to the door stop.

Alternative *
Rec:
(Where
Available)

Men's Restroom in Building 3

Full Rec Install a panel or replace the door to provide a smooth, Citation CBC 1133B.2.6
uninterrupted surface for the bottom 10 inches of the door.

Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 497
Priority:

Restrooms
Finding: The height of the urinal rim in the restroom is greater than 17
inches above the finished floor.

Alternative *
Rec:
(Where
Available)

Men's Restroom in Building 3

Full Rec Lower the urinal designated to be accessible in the restroom so Citation ADAAG 4.18.2
that the rim height is not more than 17 inches above the finished
floor.
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1097
Maximum Estimated Cost: 1097
Record Number 498
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 247 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the urinal flush control in the restroom is greater
than 44 inches above the finished floor.

Alternative *
Rec:
(Where
Available)

Men's Restroom in Building 3

Full Rec Lower the flush control valve on the urinal designated to be Citation ADAAG 4.18.4
accessible in the restroom to a height not greater than 44 inches
above the finished floor (see ADAAG 4.18.4).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 951
Maximum Estimated Cost: 951
Record Number 499
Priority:

Restrooms
Finding: There is insufficient clear floor space in the stall designated to
be accessible in the restroom. The door to the stall designated
to be accessible in the restroom does not close automatically.
The inside handle on the stall door is not mounted immediately
below the latch.

Alternative *
Rec:
(Where
Available)

Men's Restroom in Building 3

Full Rec Modify or replace the stall designated to be accessible in the Citation CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
restroom so that it complies with ADAAG 4.17.3, CBC 1115B
and CBC Figures 11B-1A and 1B. Standard accessible stalls
require 60 inches in width with 56 inches depth for wall-mounted Minimum Quantity 1
toilets or 59 inches depth for floor-mounted toilets to Maximum Quantity: 1
accommodate individuals in wheelchairs. The minimum width of
a front-approach doorway shall provide at least 32 inches and a Unit: Each
side-approach doorway shall provide at least 34 inches. The Minimum Estimated Cost: 4000
door shall swing outward, close automatically and provide
accessible hardware. Maximum Estimated Cost: 4000
Record Number 500
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 248 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The side grab bar in the stall designated to be accessible in the
restroom does not extend 54 inches from the back wall.

Alternative *
Rec:
(Where
Available)

Men's Restroom in Building 3

Full Rec The front end of the grab bar shall extend at least 54 inches Citation CBC 1115B.8.1; ADAAG 4.26
from the back wall and the back end of the grab bar shall be
mounted within 12 inches from the back wall. Grab bars must
be able to support a point load of at least 250 pounds and shall Minimum Quantity 1
be less than the allowable shear stress of the grab bar material. Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 531
Maximum Estimated Cost: 531
Record Number 501
Priority:

Restrooms
Finding: The height of the toilet seat in the stall designated to be
accessible in the restroom is less than 17 inches above the
finished floor.

Alternative *
Rec:
(Where
Available)

Men's Restroom in Building 3

Full Rec Remove or modify the toilet in the stall designated to be Citation ADAAG 4.16.3
accessible in the restroom so that the seat height is between 17
inches and 19 inches above the finished floor (see ADAAG
4.16.3). Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1707
Maximum Estimated Cost: 1707
Record Number 502
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 249 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The faucet controls on the lavatory in the restroom require tight
grasping, pinching, or twisting of the wrist and are not
accessible.

Alternative *
Rec:
(Where
Available)

Men's Restroom in Building 3

Full Rec Install faucet controls complying with ADAAG 4.19.5 on the Citation ADAAG 4.19.5
lavatory designated to be accessible in the restroom. Lever-
operated, push-type, touch-type or electronically controlled
mechanisms are acceptable elements (see ADAAG 4.19.5). If Minimum Quantity 1
self-closing valves are used the faucet shall remain open for at Maximum Quantity: 1
least 10 seconds.
Unit: Each
Minimum Estimated Cost: 392
Maximum Estimated Cost: 392
Record Number 503
Priority:

Restrooms
Finding: The knee clearance space under the lavatory designated to be
accessible in the restroom is less than 29 inches. The knee
depth space under the lavatory designated to be accessible in
the restroom is less than 27 inches at 8 inches under the
lavatory apron.

Alternative *
Rec:
(Where
Available)

Men's Restroom in Building 3

Full Rec Replace the lavatory designated to be accessible in the Citation ADAAG 4.19.2
restroom to provide at least 29 inches of clear knee space
between the finished floor and bottom of the lavatory apron.
Make sure to provide at least 27 inches at 8 inches under the Minimum Quantity 1
apron (see ADAAG 4.19.2). Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1286
Maximum Estimated Cost: 1286
Record Number 504
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 250 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The pipes under the lavatory in the restroom do not provide
protection against contact.

Alternative *
Rec:
(Where
Available)

Men's Restroom in Building 3

Full Rec Insulate or otherwise configure pipes under the lavatory Citation ADAAG 4.19.4
designated to be accessible in the restroom to protect against
contact (see ADAAG 4.19.4). Make certain there are no sharp
or abrasive surfaces under the lavatory. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 39
Maximum Estimated Cost: 39
Record Number 505
Priority:

Restrooms
Finding: The bottom edge of the reflecting surface of the mirror in the
restroom is greater than 40 inches above the finished floor.

Alternative *
Rec:
(Where
Available)

Men's Restroom in Building 3

Full Rec Lower the mirror in the restroom so that the bottom edge of the Citation ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG
reflecting surface is no higher than 40 inches above the finished 4.19.6
floor and the topmost portion of the reflecting surface extends at
least 74 inches above the finished floor (see ADAAG A4.19.6). Minimum Quantity 1
A single, full-length mirror is recommended since it can Maximum Quantity: 1
accommodate all people. Make certain to provide a minimum
clear floor space in front of the mirror of 30 inches in width and Unit: Each
48 inches in length. Minimum Estimated Cost: 291
Maximum Estimated Cost: 291
Record Number 506
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 251 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the controls and operating mechanisms for the
soap dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom in Building 3

Full Rec Relocate the soap dispenser in the restroom to a maximum Citation CBC 1115B.9.2; ADAAG A4.27
height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 507
Priority:

Restrooms
Finding: The height of the controls and operating mechanisms for the
paper towel dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom in Building 3

Full Rec Relocate the paper towel dispenser in the restroom to a Citation CBC 1115B.9.2; ADAAG A4.27
maximum height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 508
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 252 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: There is no signage indicating accessibility on the latch side of
the entry door of the restroom. The gender use signage on the
entrance door is not centered at 60 inches above the floor
surface.

Alternative *
Rec:
(Where
Available)

Men's Restroom in the Administration Office

Full Rec The restroom is designated accessible and should be made Citation CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7));
accessible for the facility. Post signage centered 60 inches ADAAG 4.1.6(3)(e); ADAAG 4.30
above the ground surface on the latch side of the entrance door
identifying the restroom as accessible upon completion of the Minimum Quantity 1
following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG Maximum Quantity: 1
4.1.6(3)(e). Signage shall include Braille and raised lettering,
the gender or unisex use symbol and the ISA symbol. Post Title Unit: Each
24 gender use signage on the door @ 60" o.c. a.f.f. Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 380
Priority:

Restrooms
Finding: The height of the urinal rim in the restroom is greater than 17
inches above the finished floor.

Alternative *
Rec:
(Where
Available)

Men's Restroom in the Administration Office

Full Rec Lower the urinal designated to be accessible in the restroom so Citation ADAAG 4.18.2
that the rim height is not more than 17 inches above the finished
floor.
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1097
Maximum Estimated Cost: 1097
Record Number 381
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 253 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: There is insufficient clear floor space in the stall designated to
be accessible in the restroom. The door to the stall designated
to be accessible in the restroom does not have accessible
hardware.

Alternative *
Rec:
(Where
Available)

Men's Restroom in the Administration Office

Full Rec Modify or replace the stall designated to be accessible in the Citation CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
restroom so that it complies with ADAAG 4.17.3, CBC 1115B
and CBC Figures 11B-1A and 1B. Standard accessible stalls
require 60 inches in width with 56 inches depth for wall-mounted Minimum Quantity 1
toilets or 59 inches depth for floor-mounted toilets to Maximum Quantity: 1
accommodate individuals in wheelchairs. The minimum width of
a front-approach doorway shall provide at least 32 inches and a Unit: Each
side-approach doorway shall provide at least 34 inches. The Minimum Estimated Cost: 4000
door shall swing outward, close automatically and provide
accessible hardware. Maximum Estimated Cost: 4000
Record Number 382
Priority:

Restrooms
Finding: The height of the coat hook on the stall door designated to be
accessible in the restroom is greater than 48 inches above the
floor surface.

Alternative *
Rec:
(Where
Available)

Men's Restroom in the Administration Office

Full Rec Remount the coat hook on the stall door designated to be Citation CBC 1115B.9.2; ADAAG A4.27
accessible in the restroom to a maximum height of 48 inches
above the floor surface.
Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 383
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 254 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the back grab bar in the stall designated to be
accessible of the restroom is less than 33 inches above the
finished floor. The height of the side grab bar in the stall
designated to be accessible of the restroom is greater than 33
inches above the finished floor.

Alternative *
Rec:
(Where
Available)

Men's Restroom in the Administration Office

Full Rec Remount the side and back grab bar in the stall designated to Citation CBC 1115B.8.1; ADAAG 4.26
be accessible in the restroom so that the height of the gripping
surface is centered at 33 inches above finished floor. Grab bars
must be able to support a point load of at least 250 pounds and Minimum Quantity 1
shall be less than the allowable shear stress of the grab bar Maximum Quantity: 1
material.
Unit: Each
Minimum Estimated Cost: 448
Maximum Estimated Cost: 448
Record Number 384
Priority:

Restrooms
Finding: The side grab bar in the stall designated to be accessible in the
restroom does not extend 54 inches from the back wall.

Alternative *
Rec:
(Where
Available)

Men's Restroom in the Administration Office

Full Rec The front end of the grab bar shall extend at least 54 inches Citation CBC 1115B.8.1; ADAAG 4.26
from the back wall and the back end of the grab bar shall be
mounted within 12 inches from the back wall. Grab bars must
be able to support a point load of at least 250 pounds and shall Minimum Quantity 1
be less than the allowable shear stress of the grab bar material. Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 531
Maximum Estimated Cost: 531
Record Number 385
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 255 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The flush control on the toilet in the stall designated to be
accessible in the restroom is not on the wide (approach) side of
the toilet.

Alternative *
Rec:
(Where
Available)

Men's Restroom in the Administration Office

Full Rec Relocate the flush control on the toilet in the stall designated to Citation ADAAG 4.16.5; ADAAG 4.27.4
be accessible in the restroom so that it is on the wide
(approach) side of the toilet area (see ADAAG 4.16.5). Flush
controls shall be hand-operated or automatic mechanisms. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 127
Maximum Estimated Cost: 127
Record Number 386
Priority:

Restrooms
Finding: The seat cover dispenser in the stall designated to be
accessible in the restroom is mounted at a height greater than
40 inches and there is no clear floor space.

Alternative *
Rec:
(Where
Available)

Men's Restroom in the Administration Office

Full Rec Relocate the seat cover dispenser in the stall designated to be Citation CBC 1115B.9.2
accessible in the restroom so that the height is no greater than
40 inches above the finished floor (see CBC 1115B.9.2). Make
certain that the location of the seat cover dispenser does not Minimum Quantity 1
interfere with the use of a grab bar and provides sufficient clear Maximum Quantity: 1
floor space.
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 387
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 256 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The knee clearance space under the lavatory designated to be
accessible in the restroom is less than 29 inches. The knee
depth space under the lavatory designated to be accessible in
the restroom is less than 27 inches at 8 inches under the
lavatory apron.

Alternative *
Rec:
(Where
Available)

Men's Restroom in the Administration Office

Full Rec Replace the lavatory designated to be accessible in the Citation ADAAG 4.19.2
restroom to provide at least 29 inches of clear knee space
between the finished floor and bottom of the lavatory apron.
Make sure to provide at least 27 inches at 8 inches under the Minimum Quantity 1
apron (see ADAAG 4.19.2). Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1286
Maximum Estimated Cost: 1286
Record Number 388
Priority:

Restrooms
Finding: The height of the controls and operating mechanisms for the
paper towel dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom in the Administration Office

Full Rec Relocate the paper towel dispenser in the restroom to a Citation CBC 1115B.9.2; ADAAG A4.27
maximum height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 389
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 257 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: There is signage indicating accessibility on the entry door to the
restroom. The signage is centered 60 inches above the floor on
the latch side of the entrance door and includes Braille and
raised lettering, gender use symbol and the ISA symbol.

Alternative *
Rec:
(Where
Available)

Men's Restroom in the Winner's Building (Champions


Section)

Full Rec The restroom is designated accessible and should be made an Citation CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7));
accessible restroom for the facility. Monitor signage for ADAAG 4.1.6(3)(e); ADAAG 4.30
continued compliance with CBC 1115B.5, ADAAG 4.1.2(7) and
ADAAG 4.1.6(3)(e)) and ADAAG 4.30. Minimum Quantity 1
Maximum Quantity: 1
Unit: None Selected
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 1119
Priority:

Restrooms
Finding: The urinal in the restroom does not extend at least 14 inches
from the back wall.

Alternative *
Rec:
(Where
Available)

Men's Restroom in the Winner's Building (Champions


Section)

Full Rec Replace the urinal designated to be accessible in the restroom Citation ADAAG 4.18.2
with a wall-mounted or stall-type tapered, elongated rim unit
complying with ADAAG 4.18.2. The height of the rim surface of
the urinal designated to be accessible shall not exceed 17 Minimum Quantity 1
inches above the finished floor and the flush control valve shall Maximum Quantity: 1
not exceed a height of 44 inches above the finished floor.
Unit: Each
Minimum Estimated Cost: 951
Maximum Estimated Cost: 951
Record Number 1120
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 258 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: There is insufficient clear floor space in the stall designated to
be accessible in the restroom. The door to the stall designated
to be accessible in the restroom does not close automatically or
have accessible hardware.

Alternative *
Rec:
(Where
Available)

Men's Restroom in the Winner's Building (Champions


Section)

Full Rec Modify or replace the stall designated to be accessible in the Citation CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
restroom so that it complies with ADAAG 4.17.3, CBC 1115B
and CBC Figures 11B-1A and 1B. Standard accessible stalls
require 60 inches in width with 56 inches depth for wall-mounted Minimum Quantity 1
toilets or 59 inches depth for floor-mounted toilets to Maximum Quantity: 1
accommodate individuals in wheelchairs. The minimum width of
a front-approach doorway shall provide at least 32 inches and a Unit: Each
side-approach doorway shall provide at least 34 inches. The Minimum Estimated Cost: 4000
door shall swing outward, close automatically and provide
accessible hardware. Maximum Estimated Cost: 4000
Record Number 1121
Priority:

Restrooms
Finding: The location of the toilet paper dispenser in the stall designated
to be accessible in the restroom is not within 12 inches of the
front edge of the toilet seat.

Alternative *
Rec:
(Where
Available)

Men's Restroom in the Winner's Building (Champions


Section)

Full Rec Remount the toilet paper dispenser in the stall designated to be Citation CBC 1115B.9.3; ADAAG 4.16.6
accessible in the restroom so that it is within 12 inches from the
front edge of the toilet seat (see CBC 1115B.9.3 and ADAAG
Figure 29(b)). Toilet paper dispensers must allow continuous Minimum Quantity 1
paper flow and shall not interfere with the use of the side grab Maximum Quantity: 1
bar.
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 1122
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 259 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The distance from the center of the toilet to the nearest side
wall in the stall designated to be accessible in the restroom is
less than 18 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom in the Winner's Building (Champions


Section)

Full Rec Relocate the toilet or stall side wall so that the distance from the Citation CBC 1115B.7.1.3 ADAAG 4.17.3
centerline of the toilet to the nearest side wall in the stall
designated to be accessible in the restroom is exactly 18 inches
(see ADAAG Figure 28. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1143
Maximum Estimated Cost: 1143
Record Number 1123
Priority:

Restrooms
Finding: The seat cover dispenser in the stall designated to be
accessible in the restroom is mounted at a height greater than
40 inches and there is no clear floor space.

Alternative *
Rec:
(Where
Available)

Men's Restroom in the Winner's Building (Champions


Section)

Full Rec Relocate the seat cover dispenser in the stall designated to be Citation CBC 1115B.9.2
accessible in the restroom so that the height is no greater than
40 inches above the finished floor (see CBC 1115B.9.2). Make
certain that the location of the seat cover dispenser does not Minimum Quantity 1
interfere with the use of a grab bar and provides sufficient clear Maximum Quantity: 1
floor space.
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 1124
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 260 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The distance from the center of the lavatory to the adjacent side
wall in the restroom is less than 18 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom in the Winner's Building (Champions


Section)

Full Rec Relocate the lavatory to provide a centerline of at least 18 Citation ADAAG 4.19.3
inches. Make sure to provide at least 30 inches in width and 48
inch length of clear floor space to allow an accessible forward
approach (see ADAAG 4.19.3). Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 1125
Priority:

Restrooms
Finding: The bottom edge of the reflecting surface of the mirror in the
restroom is greater than 40 inches above the finished floor.

Alternative *
Rec:
(Where
Available)

Men's Restroom in the Winner's Building (Champions


Section)

Full Rec Lower the mirror in the restroom so that the bottom edge of the Citation ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG
reflecting surface is no higher than 40 inches above the finished 4.19.6
floor and the topmost portion of the reflecting surface extends at
least 74 inches above the finished floor (see ADAAG A4.19.6). Minimum Quantity 1
A single, full-length mirror is recommended since it can Maximum Quantity: 1
accommodate all people. Make certain to provide a minimum
clear floor space in front of the mirror of 30 inches in width and Unit: Each
48 inches in length. Minimum Estimated Cost: 291
Maximum Estimated Cost: 291
Record Number 1126
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 261 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: There is no signage indicating accessibility on the latch side of
the entry door of the restroom. The gender use signage on the
entrance door does not include the International Symbol of
Accessibility.

Alternative *
Rec:
(Where
Available)

Men's Restroom Next to Horse Barn C

Full Rec The restroom is designated accessible and should be made Citation CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7));
accessible for the facility. Post signage centered 60 inches ADAAG 4.1.6(3)(e); ADAAG 4.30
above the ground surface on the latch side of the entrance door
identifying the restroom as accessible upon completion of the Minimum Quantity 1
following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG Maximum Quantity: 1
4.1.6(3)(e). Signage shall include Braille and raised lettering,
the gender or unisex use symbol and the ISA symbol. Post Title Unit: Each
24 gender use signage on the door @ 60" o.c. a.f.f. Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 901
Priority:

Restrooms
Finding: The urinal in the restroom does not extend at least 14 inches
from the back wall. The height of the urinal rim is greater than
17 inches above the finished floor.

Alternative *
Rec:
(Where
Available)

Men's Restroom Next to Horse Barn C

Full Rec Replace the urinal designated to be accessible in the restroom Citation ADAAG 4.18.2
with a wall-mounted or stall-type tapered, elongated rim unit
complying with ADAAG 4.18.2. The height of the rim surface of
the urinal designated to be accessible shall not exceed 17 Minimum Quantity 1
inches above the finished floor and the flush control valve shall Maximum Quantity: 1
not exceed a height of 44 inches above the finished floor.
Unit: Each
Minimum Estimated Cost: 951
Maximum Estimated Cost: 951
Record Number 902
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 262 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: There is insufficient clear floor space in the stall designated to
be accessible in the restroom. The stall door to the stall
designated to be accessible in the restroom swings inward
limiting the clear floor space in the stall designated to be
accessible. The door to the stall designated to be accessible in
the restroom does not close automatically or have accessible
hardware.

Alternative *
Rec:
(Where
Available)

Men's Restroom Next to Horse Barn C

Full Rec Modify or replace the stall designated to be accessible in the Citation CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
restroom so that it complies with ADAAG 4.17.3, CBC 1115B
and CBC Figures 11B-1A and 1B. Standard accessible stalls
require 60 inches in width with 56 inches depth for wall-mounted Minimum Quantity 1
toilets or 59 inches depth for floor-mounted toilets to Maximum Quantity: 1
accommodate individuals in wheelchairs. The minimum width of
a front-approach doorway shall provide at least 32 inches and a Unit: Each
side-approach doorway shall provide at least 34 inches. The Minimum Estimated Cost: 4000
door shall swing outward, close automatically and provide
accessible hardware. Maximum Estimated Cost: 4000
Record Number 903
Priority:

Restrooms
Finding: The height of the coat hook on the stall door designated to be
accessible in the restroom is greater than 48 inches above the
floor surface.

Alternative *
Rec:
(Where
Available)

Men's Restroom Next to Horse Barn C

Full Rec Remount the coat hook on the stall door designated to be Citation CBC 1115B.9.2; ADAAG A4.27
accessible in the restroom to a maximum height of 48 inches
above the floor surface.
Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 904
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 263 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: There are no grab bars in the stall designated to be accessible
in the restroom.

Alternative *
Rec:
(Where
Available)

Men's Restroom Next to Horse Barn C

Full Rec Install one 36-inch back grab bar and one 42/48-inch side grab Citation CBC 1115B.8; ADAAG 4.26
bar in the stall designated to be accessible in the restroom.
Grab bars shall be mounted at a height of 33 inches above the
finished floor. Grab bars must be able to support a point load of Minimum Quantity 1
at least 250 pounds and shall be less than the allowable shear Maximum Quantity: 1
stress of the grab bar material.
Unit: Each
Minimum Estimated Cost: 531
Maximum Estimated Cost: 531
Record Number 905
Priority:

Restrooms
Finding: The height of the toilet seat in the stall designated to be
accessible in the restroom is less than 17 inches above the
finished floor.

Alternative *
Rec:
(Where
Available)

Men's Restroom Next to Horse Barn C

Full Rec Remove or modify the toilet in the stall designated to be Citation ADAAG 4.16.3
accessible in the restroom so that the seat height is between 17
inches and 19 inches above the finished floor (see ADAAG
4.16.3). Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1707
Maximum Estimated Cost: 1707
Record Number 907
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 264 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The distance from the center of the toilet to the nearest side
wall in the stall designated to be accessible in the restroom is
less than 18 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom Next to Horse Barn C

Full Rec Relocate the toilet or stall side wall so that the distance from the Citation CBC 1115B.7.1.3 ADAAG 4.17.3
centerline of the toilet to the nearest side wall in the stall
designated to be accessible in the restroom is exactly 18 inches
(see ADAAG Figure 28. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1143
Maximum Estimated Cost: 1143
Record Number 908
Priority:

Restrooms
Finding: The seat cover dispenser in the stall designated to be
accessible in the restroom is mounted at a height greater than
40 inches and there is no clear floor space.

Alternative *
Rec:
(Where
Available)

Men's Restroom Next to Horse Barn C

Full Rec Relocate the seat cover dispenser in the stall designated to be Citation CBC 1115B.9.2
accessible in the restroom so that the height is no greater than
40 inches above the finished floor (see CBC 1115B.9.2). Make
certain that the location of the seat cover dispenser does not Minimum Quantity 1
interfere with the use of a grab bar and provides sufficient clear Maximum Quantity: 1
floor space.
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 909
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 265 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The knee depth space under the lavatory designated to be
accessible in the restroom is less than 27 inches at 8 inches
under the lavatory apron.

Alternative *
Rec:
(Where
Available)

Men's Restroom Next to Horse Barn C

Full Rec Raise or replace the lavatory designated to be accessible in the Citation ADAAG 4.19.2
restroom to provide at least 27 inches at 8 inches under the
apron. Make sure to provide at least 29 inches of clear knee
space between the finished floor and bottom of the lavatory Minimum Quantity 1
apron and a rim surface height no greater than 34 inches (see Maximum Quantity: 1
ADAAG 4.19.2).
Unit: Each
Minimum Estimated Cost: 1286
Maximum Estimated Cost: 1286
Record Number 910
Priority:

Restrooms
Finding: The pipes under the lavatory in the restroom do not provide
protection against contact.

Alternative *
Rec:
(Where
Available)

Men's Restroom Next to Horse Barn C

Full Rec Insulate or otherwise configure pipes under the lavatory Citation ADAAG 4.19.4
designated to be accessible in the restroom to protect against
contact (see ADAAG 4.19.4). Make certain there are no sharp
or abrasive surfaces under the lavatory. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 39
Maximum Estimated Cost: 39
Record Number 911
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 266 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The bottom edge of the reflecting surface of the mirror in the
restroom is greater than 40 inches above the finished floor.

Alternative *
Rec:
(Where
Available)

Men's Restroom Next to Horse Barn C

Full Rec Lower the mirror in the restroom so that the bottom edge of the Citation ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG
reflecting surface is no higher than 40 inches above the finished 4.19.6
floor and the topmost portion of the reflecting surface extends at
least 74 inches above the finished floor (see ADAAG A4.19.6). Minimum Quantity 1
A single, full-length mirror is recommended since it can Maximum Quantity: 1
accommodate all people. Make certain to provide a minimum
clear floor space in front of the mirror of 30 inches in width and Unit: Each
48 inches in length. Minimum Estimated Cost: 291
Maximum Estimated Cost: 291
Record Number 912
Priority:

Restrooms
Finding: The height of the controls and operating mechanisms for the
soap dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom Next to Horse Barn C

Full Rec Relocate the soap dispenser in the restroom to a maximum Citation CBC 1115B.9.2; ADAAG A4.27
height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 913
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 267 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the controls and operating mechanisms for the
paper towel dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom Next to Horse Barn C

Full Rec Relocate the paper towel dispenser in the restroom to a Citation CBC 1115B.9.2; ADAAG A4.27
maximum height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 914
Priority:

Restrooms
Finding: The clear opening width of the entrance to the showers in the
restroom is less than 32 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom Next to Horse Barn C

Full Rec Widen the entrance doorway to the showers in the restroom to Citation ADAAG 4.13.5
provide a clear opening width of at least 32 inches when the
door is open 90 degrees (see ADAAG 4.13.5).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 750
Maximum Estimated Cost: 750
Record Number 915
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 268 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The latch side approach to the shower stall designated to be
accessible in the restroom is less than 44 inches wide.

Alternative *
Rec:
(Where
Available)

Men's Restroom Next to Horse Barn C

Full Rec Consult a design professional to provide a latch-side approach Citation CBC 1115B.7.1.3; ADAAG 4.17.3
to the stall designated to be accessible with a clear,
unobstructed access width of 44 inches with the space
immediately in front of the stall door at 48 inches in width. All Minimum Quantity 1
other approaches require 48 inches of clear, unobstructed Maximum Quantity: 1
access to and in front of the stall designated to be accessible in
the restroom. Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 916
Priority:

Restrooms
Finding: Showering facilities are provided, though are not required. The
restroom provides two private shower stalls. There are no
accessible shower stalls provided in the restroom.

Alternative *
Rec:
(Where
Available)

Men's Restroom Next to Horse Barn C

Full Rec Since shower stalls are provided in the restroom, at least one Citation CBC 1115B.6.2; ADAAG 4.21
accessible shower stall is required. Install an accessible shower
stall complying with CBC 1115B 6.2 and ADAAG 4.21 in the
restroom. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 2853
Maximum Estimated Cost: 2853
Record Number 917
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 269 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The gender use signage is not mounted on the entrance door
and is not centered at 60 inches above the floor surface.

Alternative *
Rec:
(Where
Available)

Men's Restroom Next to Horse Barn K

Full Rec The restroom is designated accessible and should be made Citation CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7));
accessible for the facility. Post Title 24 gender use signage on ADAAG 4.1.6(3)(e); ADAAG 4.30
the door @ 60" o.c. a.f.f.
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 935
Priority:

Restrooms
Finding: The door to the stall designated to be accessible in the
restroom does not close automatically or have accessible
hardware.

Alternative *
Rec:
(Where
Available)

Men's Restroom Next to Horse Barn K

Full Rec Provide an automatic door closer, spring hinge, pull bar or Citation ADAAG A4.17.5
accessible handle mounted on the inside of the stall door to the
stall designated to be accessible in the restroom (see ADAAG
A4.17.5). Accessible hardware on the inside and outside of the Minimum Quantity 1
stall designated to be accessible door shall be equipped with a Maximum Quantity: 1
loop or U-shaped handle mounted immediately below the latch.
The latch shall be flip-over style, sliding or other hardware not Unit: Each
requiring grasping or twisting. Make certain that the inside and Minimum Estimated Cost: 269
outside door hardware is mounted no more than 48 inches
above the finished floor (see CBC 115B.7.1.3 and ADAAG Maximum Estimated Cost: 269
4.13.9). Record Number 936
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 270 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: There is less than 48 inches of clear floor space provided in
front of the water closet in the restroom to allow an accessible
forward approach.

Alternative *
Rec:
(Where
Available)

Men's Restroom Next to Horse Barn K

Full Rec The minimum clear floor space in front of the water closet Citation CBC 1115B.9.4; ADAAG 4.18.3
designated to be accessible in the restroom shall be at least 48
inches to provide an accessible forward approach. Consult a
design professional to determine if elements or walls need to be Minimum Quantity 1
removed to provide sufficient clear floor space in front of the Maximum Quantity: 1
water closet.
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 937
Priority:

Restrooms
Finding: The height of the coat hook on the stall door designated to be
accessible in the restroom is greater than 48 inches above the
floor surface.

Alternative *
Rec:
(Where
Available)

Men's Restroom Next to Horse Barn K

Full Rec Remount the coat hook on the stall door designated to be Citation CBC 1115B.9.2; ADAAG A4.27
accessible in the restroom to a maximum height of 48 inches
above the floor surface.
Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 938
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 271 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the side grab bar in the stall designated to be
accessible of the restroom is greater than 33 inches above the
finished floor.

Alternative *
Rec:
(Where
Available)

Men's Restroom Next to Horse Barn K

Full Rec Remount the side grab bar in the stall designated to be Citation CBC 1115B.8.1; ADAAG 4.26
accessible in the restroom so that the height of the gripping
surface is centered at 33 inches above finished floor. Grab bars
must be able to support a point load of at least 250 pounds and Minimum Quantity 1
shall be less than the allowable shear stress of the grab bar Maximum Quantity: 1
material.
Unit: Each
Minimum Estimated Cost: 448
Maximum Estimated Cost: 448
Record Number 939
Priority:

Restrooms
Finding: The distance from the center of the toilet to the nearest side
wall in the stall designated to be accessible in the restroom is
greater than 18 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom Next to Horse Barn K

Full Rec Relocate the toilet or stall side wall so that the distance from the Citation CBC 1115B.7.1.3 ADAAG 4.17.3
centerline of the toilet to the nearest side wall in the stall
designated to be accessible in the restroom is exactly 18 inches
(see ADAAG Figure 28. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1143
Maximum Estimated Cost: 1143
Record Number 941
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 272 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The distance from the center of the lavatory to the adjacent side
wall in the restroom is less than 18 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom Next to Horse Barn K

Full Rec Relocate the lavatory to provide a centerline of at least 18 Citation ADAAG 4.19.3
inches. Make sure to provide at least 30 inches in width and 48
inch length of clear floor space to allow an accessible forward
approach (see ADAAG 4.19.3). Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 942
Priority:

Restrooms
Finding: The knee clearance space under the lavatory designated to be
accessible in the restroom is less than 29 inches. The knee
depth space under the lavatory designated to be accessible in
the restroom is less than 27 inches at 8 inches under the
lavatory apron.

Alternative *
Rec:
(Where
Available)

Men's Restroom Next to Horse Barn K

Full Rec Replace the lavatory designated to be accessible in the Citation ADAAG 4.19.2
restroom to provide at least 29 inches of clear knee space
between the finished floor and bottom of the lavatory apron.
Make sure to provide at least 27 inches at 8 inches under the Minimum Quantity 1
apron (see ADAAG 4.19.2). Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1286
Maximum Estimated Cost: 1286
Record Number 943
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 273 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The pipes under the lavatory in the restroom do not provide
protection against contact.

Alternative *
Rec:
(Where
Available)

Men's Restroom Next to Horse Barn K

Full Rec Insulate or otherwise configure pipes under the lavatory Citation ADAAG 4.19.4
designated to be accessible in the restroom to protect against
contact (see ADAAG 4.19.4). Make certain there are no sharp
or abrasive surfaces under the lavatory. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 39
Maximum Estimated Cost: 39
Record Number 944
Priority:

Restrooms
Finding: The height of the controls and operating mechanisms for the
soap dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom Next to Horse Barn K

Full Rec Relocate the soap dispenser in the restroom to a maximum Citation CBC 1115B.9.2; ADAAG A4.27
height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 945
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 274 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the controls and operating mechanisms for the
paper towel dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom Next to Horse Barn K

Full Rec Relocate the paper towel dispenser in the restroom to a Citation CBC 1115B.9.2; ADAAG A4.27
maximum height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 946
Priority:

Restrooms
Finding: The soap dish in the shower compartment designated to be
accessible in the restroom is mounted at a height greater than
40 inches above the shower floor.

Alternative *
Rec:
(Where
Available)

Men's Restroom Next to Horse Barn K

Full Rec Relocate the soap dish mounted in the shower compartment Citation CBC 1115B.6.2.4.6
designated to be accessible in the restroom so that it is
mounted on the same wall as the water controls at a maximum
height of 40 inches above the shower floor (see CBC Minimum Quantity 1
1115B.6.2.4.6). Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 1200
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 275 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: There is no signage indicating accessibility on the latch side of
the entry door of the restroom. The gender use signage is not
mounted on the entrance door and is not centered at 60 inches
above the floor surface.

Alternative *
Rec:
(Where
Available)

Men's Restroom Next to the Livestock Office

Full Rec The restroom is designated accessible and should be made Citation CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7));
accessible for the facility. Post signage centered 60 inches ADAAG 4.1.6(3)(e); ADAAG 4.30
above the ground surface on the latch side of the entrance door
identifying the restroom as accessible upon completion of the Minimum Quantity 1
following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG Maximum Quantity: 1
4.1.6(3)(e). Signage shall include Braille and raised lettering,
the gender or unisex use symbol and the ISA symbol. Post Title Unit: Each
24 gender use signage on the door @ 60" o.c. a.f.f. Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 700
Priority:

Restrooms
Finding: The clear opening width of the entrance doorway to the
restroom is less than 32 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom Next to the Livestock Office

Full Rec Widen the entrance doorway to the restroom to provide a clear Citation ADAAG 4.13.5
opening width of at least 32 inches when the door is open 90
degrees (see ADAAG 4.13.5).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 750
Maximum Estimated Cost: 750
Record Number 701
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 276 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The urinal in the restroom is floor mounted and does not provide
a tapered, elongated rim.

Alternative *
Rec:
(Where
Available)

Men's Restroom Next to the Livestock Office

Full Rec Replace the urinal designated to be accessible in the restroom Citation ADAAG 4.18.2
with a wall-mounted or stall-type tapered, elongated rim unit
complying with ADAAG 4.18.2. The height of the rim surface of
the urinal designated to be accessible shall not exceed 17 Minimum Quantity 1
inches above the finished floor and the flush control valve shall Maximum Quantity: 1
not exceed a height of 44 inches above the finished floor.
Unit: Each
Minimum Estimated Cost: 951
Maximum Estimated Cost: 951
Record Number 702
Priority:

Restrooms
Finding: There is insufficient clear floor space in the stall designated to
be accessible in the restroom. The door to the stall designated
to be accessible in the restroom does not close automatically or
have accessible hardware.

Alternative *
Rec:
(Where
Available)

Men's Restroom Next to the Livestock Office

Full Rec Modify or replace the stall designated to be accessible in the Citation CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
restroom so that it complies with ADAAG 4.17.3, CBC 1115B
and CBC Figures 11B-1A and 1B. Standard accessible stalls
require 60 inches in width with 56 inches depth for wall-mounted Minimum Quantity 1
toilets or 59 inches depth for floor-mounted toilets to Maximum Quantity: 1
accommodate individuals in wheelchairs. The minimum width of
a front-approach doorway shall provide at least 32 inches and a Unit: Each
side-approach doorway shall provide at least 34 inches. The Minimum Estimated Cost: 4000
door shall swing outward, close automatically and provide
accessible hardware. Maximum Estimated Cost: 4000
Record Number 703
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 277 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: There is no back grab bar in the stall designated to be
accessible in the restroom.

Alternative *
Rec:
(Where
Available)

Men's Restroom Next to the Livestock Office

Full Rec Install a 36-inch back grab bar at a height of 33 inches above Citation CBC 1115B.8.1; ADAAG 4.26
the finished floor in the stall designated to be accessible of the
restroom. Grab bars must be able to support a point load of at
least 250 pounds and shall be less than the allowable shear Minimum Quantity 1
stress of the grab bar material. Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 531
Maximum Estimated Cost: 531
Record Number 704
Priority:

Restrooms
Finding: The height of the side grab bars in the stall designated to be
accessible of the restroom is greater than 33 inches above the
finished floor.

Alternative *
Rec:
(Where
Available)

Men's Restroom Next to the Livestock Office

Full Rec Remount the side grab bars in the stall designated to be Citation CBC 1115B.8.1; ADAAG 4.26
accessible in the restroom so that the height of the gripping
surface is centered at 33 inches above finished floor. Grab bars
must be able to support a point load of at least 250 pounds and Minimum Quantity 1
shall be less than the allowable shear stress of the grab bar Maximum Quantity: 1
material.
Unit: Each
Minimum Estimated Cost: 448
Maximum Estimated Cost: 448
Record Number 705
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 278 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The side grab bars in the stall designated to be accessible in
the restroom do not extend 54 inches from the back wall.

Alternative *
Rec:
(Where
Available)

Men's Restroom Next to the Livestock Office

Full Rec The front end of the grab bar shall extend at least 54 inches Citation CBC 1115B.8.1; ADAAG 4.26
from the back wall and the back end of the grab bar shall be
mounted within 12 inches from the back wall. Grab bars must
be able to support a point load of at least 250 pounds and shall Minimum Quantity 1
be less than the allowable shear stress of the grab bar material. Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 531
Maximum Estimated Cost: 531
Record Number 706
Priority:

Restrooms
Finding: The height of the toilet seat in the stall designated to be
accessible in the restroom is less than 17 inches above the
finished floor.

Alternative *
Rec:
(Where
Available)

Men's Restroom Next to the Livestock Office

Full Rec Remove or modify the toilet in the stall designated to be Citation ADAAG 4.16.3
accessible in the restroom so that the seat height is between 17
inches and 19 inches above the finished floor (see ADAAG
4.16.3). Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1707
Maximum Estimated Cost: 1707
Record Number 707
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 279 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The seat cover dispenser in the stall designated to be
accessible in the restroom is mounted at a height greater than
40 inches and there is no clear floor space.

Alternative *
Rec:
(Where
Available)

Men's Restroom Next to the Livestock Office

Full Rec Relocate the seat cover dispenser in the stall designated to be Citation CBC 1115B.9.2
accessible in the restroom so that the height is no greater than
40 inches above the finished floor (see CBC 1115B.9.2). Make
certain that the location of the seat cover dispenser does not Minimum Quantity 1
interfere with the use of a grab bar and provides sufficient clear Maximum Quantity: 1
floor space.
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 708
Priority:

Restrooms
Finding: The knee clearance space under the lavatory designated to be
accessible in the restroom is less than 29 inches. The knee
depth space under the lavatory designated to be accessible in
the restroom is less than 27 inches at 8 inches under the
lavatory apron.

Alternative *
Rec:
(Where
Available)

Men's Restroom Next to the Livestock Office

Full Rec Replace the lavatory designated to be accessible in the Citation ADAAG 4.19.2
restroom to provide at least 29 inches of clear knee space
between the finished floor and bottom of the lavatory apron.
Make sure to provide at least 27 inches at 8 inches under the Minimum Quantity 1
apron (see ADAAG 4.19.2). Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1286
Maximum Estimated Cost: 1286
Record Number 709
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 280 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The pipes under the lavatory in the restroom do not provide
protection against contact.

Alternative *
Rec:
(Where
Available)

Men's Restroom Next to the Livestock Office

Full Rec Insulate or otherwise configure pipes under the lavatory Citation ADAAG 4.19.4
designated to be accessible in the restroom to protect against
contact (see ADAAG 4.19.4). Make certain there are no sharp
or abrasive surfaces under the lavatory. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 39
Maximum Estimated Cost: 39
Record Number 710
Priority:

Restrooms
Finding: The bottom edge of the reflecting surface of the mirror in the
restroom is greater than 40 inches above the finished floor.

Alternative *
Rec:
(Where
Available)

Men's Restroom Next to the Livestock Office

Full Rec Lower the mirror in the restroom so that the bottom edge of the Citation ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG
reflecting surface is no higher than 40 inches above the finished 4.19.6
floor and the topmost portion of the reflecting surface extends at
least 74 inches above the finished floor (see ADAAG A4.19.6). Minimum Quantity 1
A single, full-length mirror is recommended since it can Maximum Quantity: 1
accommodate all people. Make certain to provide a minimum
clear floor space in front of the mirror of 30 inches in width and Unit: Each
48 inches in length. Minimum Estimated Cost: 291
Maximum Estimated Cost: 291
Record Number 711
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 281 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the controls and operating mechanisms for the
paper towel dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom Next to the Livestock Office

Full Rec Relocate the paper towel dispenser in the restroom to a Citation CBC 1115B.9.2; ADAAG A4.27
maximum height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 712
Priority:

Restrooms
Finding: There is no Title 24 gender use signage on the entrance door.

Alternative *
Rec:
(Where
Available)

Men's Restroom on the Second Floor of the Grandstands

Full Rec The restroom is designated accessible and should be made Citation CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7));
accessible for the facility. Post Title 24 gender use signage on ADAAG 4.1.6(3)(e); ADAAG 4.30
the door @ 60" o.c. a.f.f.
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 888
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 282 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the urinal rim in the restroom is greater than 17
inches above the finished floor.

Alternative *
Rec:
(Where
Available)

Men's Restroom on the Second Floor of the Grandstands

Full Rec Lower the urinal designated to be accessible in the restroom so Citation ADAAG 4.18.2
that the rim height is not more than 17 inches above the finished
floor.
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1097
Maximum Estimated Cost: 1097
Record Number 889
Priority:

Restrooms
Finding: The height of the side grab bars in the stall designated to be
accessible of the restroom is less than 33 inches above the
finished floor.

Alternative *
Rec:
(Where
Available)

Men's Restroom on the Second Floor of the Grandstands

Full Rec Remount the side grab bars in the stall designated to be Citation CBC 1115B.8.1; ADAAG 4.26
accessible in the restroom so that the height of the gripping
surface is centered at 33 inches above finished floor. Grab bars
must be able to support a point load of at least 250 pounds and Minimum Quantity 1
shall be less than the allowable shear stress of the grab bar Maximum Quantity: 1
material.
Unit: Each
Minimum Estimated Cost: 448
Maximum Estimated Cost: 448
Record Number 890
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 283 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The location of the toilet paper dispenser in the stall designated
to be accessible in the restroom is not within 12 inches of the
front edge of the toilet seat. The toilet paper dispenser
protrudes more than 4 inches from the side wall and interferes
with the clear floor space of the water closet.

Alternative *
Rec:
(Where
Available)

Men's Restroom on the Second Floor of the Grandstands

Full Rec Remount the toilet paper dispenser in the stall designated to be Citation CBC 1115B.9.3; ADAAG 4.16.6
accessible in the restroom so that it is within 12 inches from the
front edge of the toilet seat and does not encroach more than
four inches from the face of the wall (see CBC 1115B.9.3 and Minimum Quantity 1
ADAAG Figure 29(b)). Toilet paper dispensers must allow Maximum Quantity: 1
continuous paper flow and shall not interfere with the use of the
side grab bar. Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 891
Priority:

Restrooms
Finding: The height of the toilet seat in the stall designated to be
accessible in the restroom is greater than 19 inches above the
finished floor.

Alternative *
Rec:
(Where
Available)

Men's Restroom on the Second Floor of the Grandstands

Full Rec Remove or modify the toilet in the stall designated to be Citation ADAAG 4.16.3
accessible in the restroom so that the seat height is between 17
inches and 19 inches above the finished floor (see ADAAG
4.16.3). Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1707
Maximum Estimated Cost: 1707
Record Number 892
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 284 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The distance from the center of the toilet to the nearest side
wall in the stall designated to be accessible in the restroom is
greater than 18 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom on the Second Floor of the Grandstands

Full Rec Relocate the toilet or stall side wall so that the distance from the Citation CBC 1115B.7.1.3 ADAAG 4.17.3
centerline of the toilet to the nearest side wall in the stall
designated to be accessible in the restroom is exactly 18 inches
(see ADAAG Figure 28. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1143
Maximum Estimated Cost: 1143
Record Number 893
Priority:

Restrooms
Finding: The knee clearance space under the lavatory designated to be
accessible in the restroom is less than 29 inches. The knee
depth space under the lavatory designated to be accessible in
the restroom is less than 27 inches at 8 inches under the
lavatory apron.

Alternative *
Rec:
(Where
Available)

Men's Restroom on the Second Floor of the Grandstands

Full Rec Replace the lavatory designated to be accessible in the Citation ADAAG 4.19.2
restroom to provide at least 29 inches of clear knee space
between the finished floor and bottom of the lavatory apron.
Make sure to provide at least 27 inches at 8 inches under the Minimum Quantity 1
apron (see ADAAG 4.19.2). Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1286
Maximum Estimated Cost: 1286
Record Number 894
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 285 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the controls and operating mechanisms for the
paper towel dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom on the Second Floor of the Grandstands

Full Rec Relocate the paper towel dispenser in the restroom to a Citation CBC 1115B.9.2; ADAAG A4.27
maximum height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 895
Priority:

Restrooms
Finding: There is no signage indicating accessibility on the latch side of
the entry door of the restroom. The gender use signage on the
entrance door does not include the International Symbol of
Accessibility.

Alternative *
Rec:
(Where
Available)

Men's Restroom Outside of Building 2

Full Rec The restroom is designated accessible and should be made Citation CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7));
accessible for the facility. Post signage centered 60 inches ADAAG 4.1.6(3)(e); ADAAG 4.30
above the ground surface on the latch side of the entrance door
identifying the restroom as accessible upon completion of the Minimum Quantity 1
following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG Maximum Quantity: 1
4.1.6(3)(e). Signage shall include Braille and raised lettering,
the gender or unisex use symbol and the ISA symbol. Post Title Unit: Each
24 gender use signage on the door @ 60" o.c. a.f.f. Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 649
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 286 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The privacy partition at the entrance limits the minimum clear
width of the accessible route into the restroom.

Alternative *
Rec:
(Where
Available)

Men's Restroom Outside of Building 2

Full Rec Modify or remove the privacy partition at the entrance to the Citation CBC 1133B.2.4.2; ADAAG 4.13.6
restroom to provide a width of at least 60 inches in the direction
of the door swing and at least 48 inches in the opposite direction
of the door swing (see CBC 1133B.2.4.2, ADAAG 4.13.6 and Minimum Quantity 1
ADAAG Figure 25). Maximum Quantity: 1
Unit: 128 Sq Ft
Minimum Estimated Cost: 1024
Maximum Estimated Cost: 1024
Record Number 650
Priority:

Restrooms
Finding: The height of the urinal rim in the restroom is greater than 17
inches above the finished floor.

Alternative *
Rec:
(Where
Available)

Men's Restroom Outside of Building 2

Full Rec Lower the urinal designated to be accessible in the restroom so Citation ADAAG 4.18.2
that the rim height is not more than 17 inches above the finished
floor.
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1097
Maximum Estimated Cost: 1097
Record Number 651
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 287 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the urinal flush control in the restroom is greater
than 44 inches above the finished floor.

Alternative *
Rec:
(Where
Available)

Men's Restroom Outside of Building 2

Full Rec Lower the flush control valve on the urinal designated to be Citation ADAAG 4.18.4
accessible in the restroom to a height not greater than 44 inches
above the finished floor (see ADAAG 4.18.4).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 951
Maximum Estimated Cost: 951
Record Number 652
Priority:

Restrooms
Finding: There is insufficient clear floor space in the stall designated to
be accessible in the restroom. The door to the stall designated
to be accessible in the restroom does not close automatically or
have accessible hardware.

Alternative *
Rec:
(Where
Available)

Men's Restroom Outside of Building 2

Full Rec Modify or replace the stall designated to be accessible in the Citation CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
restroom so that it complies with ADAAG 4.17.3, CBC 1115B
and CBC Figures 11B-1A and 1B. Standard accessible stalls
require 60 inches in width with 56 inches depth for wall-mounted Minimum Quantity 1
toilets or 59 inches depth for floor-mounted toilets to Maximum Quantity: 1
accommodate individuals in wheelchairs. The minimum width of
a front-approach doorway shall provide at least 32 inches and a Unit: Each
side-approach doorway shall provide at least 34 inches. The Minimum Estimated Cost: 4000
door shall swing outward, close automatically and provide
accessible hardware. Maximum Estimated Cost: 4000
Record Number 653
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 288 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the coat hook on the stall door designated to be
accessible in the restroom is greater than 48 inches above the
floor surface.

Alternative *
Rec:
(Where
Available)

Men's Restroom Outside of Building 2

Full Rec Remount the coat hook on the stall door designated to be Citation CBC 1115B.9.2; ADAAG A4.27
accessible in the restroom to a maximum height of 48 inches
above the floor surface.
Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 654
Priority:

Restrooms
Finding: There is no back grab bar in the stall designated to be
accessible in the restroom.

Alternative *
Rec:
(Where
Available)

Men's Restroom Outside of Building 2

Full Rec Install a 36-inch back grab bar at a height of 33 inches above Citation CBC 1115B.8.1; ADAAG 4.26
the finished floor in the stall designated to be accessible of the
restroom. Grab bars must be able to support a point load of at
least 250 pounds and shall be less than the allowable shear Minimum Quantity 1
stress of the grab bar material. Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 531
Maximum Estimated Cost: 531
Record Number 655
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 289 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the toilet seat in the stall designated to be
accessible in the restroom is less than 17 inches above the
finished floor.

Alternative *
Rec:
(Where
Available)

Men's Restroom Outside of Building 2

Full Rec Remove or modify the toilet in the stall designated to be Citation ADAAG 4.16.3
accessible in the restroom so that the seat height is between 17
inches and 19 inches above the finished floor (see ADAAG
4.16.3). Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1707
Maximum Estimated Cost: 1707
Record Number 656
Priority:

Restrooms
Finding: The distance from the center of the toilet to the nearest side
wall in the stall designated to be accessible in the restroom is
greater than 18 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom Outside of Building 2

Full Rec Relocate the toilet or stall side wall so that the distance from the Citation CBC 1115B.7.1.3 ADAAG 4.17.3
centerline of the toilet to the nearest side wall in the stall
designated to be accessible in the restroom is exactly 18 inches
(see ADAAG Figure 28. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1143
Maximum Estimated Cost: 1143
Record Number 657
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 290 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The seat cover dispenser in the stall designated to be
accessible in the restroom is mounted at a height greater than
40 inches and there is no clear floor space.

Alternative *
Rec:
(Where
Available)

Men's Restroom Outside of Building 2

Full Rec Relocate the seat cover dispenser in the stall designated to be Citation CBC 1115B.9.2
accessible in the restroom so that the height is no greater than
40 inches above the finished floor (see CBC 1115B.9.2). Make
certain that the location of the seat cover dispenser does not Minimum Quantity 1
interfere with the use of a grab bar and provides sufficient clear Maximum Quantity: 1
floor space.
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 658
Priority:

Restrooms
Finding: The faucet controls on the lavatory in the restroom require tight
grasping, pinching, or twisting of the wrist and are not
accessible.

Alternative *
Rec:
(Where
Available)

Men's Restroom Outside of Building 2

Full Rec Install faucet controls complying with ADAAG 4.19.5 on the Citation ADAAG 4.19.5
lavatory designated to be accessible in the restroom. Lever-
operated, push-type, touch-type or electronically controlled
mechanisms are acceptable elements (see ADAAG 4.19.5). If Minimum Quantity 1
self-closing valves are used the faucet shall remain open for at Maximum Quantity: 1
least 10 seconds.
Unit: Each
Minimum Estimated Cost: 392
Maximum Estimated Cost: 392
Record Number 659
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 291 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The knee clearance space under the lavatory designated to be
accessible in the restroom is less than 29 inches. The knee
depth space under the lavatory designated to be accessible in
the restroom is less than 27 inches at 8 inches under the
lavatory apron.

Alternative *
Rec:
(Where
Available)

Men's Restroom Outside of Building 2

Full Rec Replace the lavatory designated to be accessible in the Citation ADAAG 4.19.2
restroom to provide at least 29 inches of clear knee space
between the finished floor and bottom of the lavatory apron.
Make sure to provide at least 27 inches at 8 inches under the Minimum Quantity 1
apron (see ADAAG 4.19.2). Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1286
Maximum Estimated Cost: 1286
Record Number 660
Priority:

Restrooms
Finding: The pipes under the lavatory in the restroom do not provide
protection against contact.

Alternative *
Rec:
(Where
Available)

Men's Restroom Outside of Building 2

Full Rec Insulate or otherwise configure pipes under the lavatory Citation ADAAG 4.19.4
designated to be accessible in the restroom to protect against
contact (see ADAAG 4.19.4). Make certain there are no sharp
or abrasive surfaces under the lavatory. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 39
Maximum Estimated Cost: 39
Record Number 661
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 292 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the controls and operating mechanisms for the
soap dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom Outside of Building 2

Full Rec Relocate the soap dispenser in the restroom to a maximum Citation CBC 1115B.9.2; ADAAG A4.27
height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 662
Priority:

Restrooms
Finding: The height of the controls and operating mechanisms for the
paper towel dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom Outside of Building 2

Full Rec Relocate the paper towel dispenser in the restroom to a Citation CBC 1115B.9.2; ADAAG A4.27
maximum height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 663
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 293 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The signage on the latch side of the entry door of the restroom
does not include the International Symbol of Accessibility. The
gender use signage on the entrance door is not mounted at 60
inches above the floor surface.

Alternative *
Rec:
(Where
Available)

Men's Restroom Outside of Building 3

Full Rec The restroom is designated accessible and should be made Citation CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7));
accessible for the facility. Post signage centered 60 inches ADAAG 4.1.6(3)(e); ADAAG 4.30
above the ground surface on the latch side of the entrance door
identifying the restroom as accessible upon completion of the Minimum Quantity 1
following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG Maximum Quantity: 1
4.1.6(3)(e). Signage shall include Braille and raised lettering,
the gender or unisex use symbol and the ISA symbol. Post Title Unit: Each
24 gender use signage on the door @ 60" o.c. a.f.f. Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 509
Priority:

Restrooms
Finding: The bottom 10 inches of the door does not provide a smooth,
uninterrupted surface, or panel to allow the door to be opened
by a wheelchair footrest without creating a trap or hazardous
condition, due to the door stop.

Alternative *
Rec:
(Where
Available)

Men's Restroom Outside of Building 3

Full Rec Install a panel or replace the door to provide a smooth, Citation CBC 1133B.2.6
uninterrupted surface for the bottom 10 inches of the door.

Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 510
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 294 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the urinal flush control in the restroom is greater
than 44 inches above the finished floor.

Alternative *
Rec:
(Where
Available)

Men's Restroom Outside of Building 3

Full Rec Lower the flush control valve on the urinal designated to be Citation ADAAG 4.18.4
accessible in the restroom to a height not greater than 44 inches
above the finished floor (see ADAAG 4.18.4).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 951
Maximum Estimated Cost: 951
Record Number 511
Priority:

Restrooms
Finding: The door to the stall designated to be accessible in the
restroom does not close automatically. The inside handle on
the stall door designated to be accessible.

Alternative *
Rec:
(Where
Available)

Men's Restroom Outside of Building 3

Full Rec Provide an automatic door closer, spring hinge, pull bar or Citation ADAAG A4.17.5
accessible handle mounted on the inside of the stall door to the
stall designated to be accessible in the restroom (see ADAAG
A4.17.5). Accessible hardware on the inside and outside of the Minimum Quantity 1
stall designated to be accessible door shall be equipped with a Maximum Quantity: 1
loop or U-shaped handle mounted immediately below the latch.
The latch shall be flip-over style, sliding or other hardware not Unit: Each
requiring grasping or twisting. Make certain that the inside and Minimum Estimated Cost: 269
outside door hardware is mounted no more than 48 inches
above the finished floor (see CBC 115B.7.1.3 and ADAAG Maximum Estimated Cost: 269
4.13.9). Record Number 512
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 295 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the coat hook on the stall door designated to be
accessible in the restroom is greater than 48 inches above the
floor surface.

Alternative *
Rec:
(Where
Available)

Men's Restroom Outside of Building 3

Full Rec Remount the coat hook on the stall door designated to be Citation CBC 1115B.9.2; ADAAG A4.27
accessible in the restroom to a maximum height of 48 inches
above the floor surface.
Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 513
Priority:

Restrooms
Finding: The distance from the end of the back grab bar to the nearest
side wall in the stall designated to be accessible of the restroom
is greater than 6 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom Outside of Building 3

Full Rec Remount the back grab bar in the stall designated to be Citation ADAAG 4.26; CBC 1115B.8.1
accessible in the restroom so that it is not more than 6 inches
from the nearest side wall (see ADAAG 4.26 and CBC Figure
11B.1A-1C). Grab bars must be able to support a point load of Minimum Quantity 1
at least 250 pounds and shall be less than the allowable shear Maximum Quantity: 1
stress of the grab bar material.
Unit: Each
Minimum Estimated Cost: 448
Maximum Estimated Cost: 448
Record Number 514
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 296 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The distance from the center of the toilet to the nearest side
wall in the stall designated to be accessible in the restroom is
less than 18 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom Outside of Building 3

Full Rec Relocate the toilet or stall side wall so that the distance from the Citation CBC 1115B.7.1.3 ADAAG 4.17.3
centerline of the toilet to the nearest side wall in the stall
designated to be accessible in the restroom is exactly 18 inches
(see ADAAG Figure 28. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1143
Maximum Estimated Cost: 1143
Record Number 515
Priority:

Restrooms
Finding: The seat cover dispenser in the stall designated to be
accessible in the restroom is mounted at a height greater than
40 inches and there is no clear floor space.

Alternative *
Rec:
(Where
Available)

Men's Restroom Outside of Building 3

Full Rec Relocate the seat cover dispenser in the stall designated to be Citation CBC 1115B.9.2
accessible in the restroom so that the height is no greater than
40 inches above the finished floor (see CBC 1115B.9.2). Make
certain that the location of the seat cover dispenser does not Minimum Quantity 1
interfere with the use of a grab bar and provides sufficient clear Maximum Quantity: 1
floor space.
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 516
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 297 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The bottom edge of the reflecting surface of the mirror in the
restroom is greater than 40 inches above the finished floor.

Alternative *
Rec:
(Where
Available)

Men's Restroom Outside of Building 3

Full Rec Lower the mirror in the restroom so that the bottom edge of the Citation ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG
reflecting surface is no higher than 40 inches above the finished 4.19.6
floor and the topmost portion of the reflecting surface extends at
least 74 inches above the finished floor (see ADAAG A4.19.6). Minimum Quantity 1
A single, full-length mirror is recommended since it can Maximum Quantity: 1
accommodate all people. Make certain to provide a minimum
clear floor space in front of the mirror of 30 inches in width and Unit: Each
48 inches in length. Minimum Estimated Cost: 291
Maximum Estimated Cost: 291
Record Number 517
Priority:

Restrooms
Finding: The height of the controls and operating mechanisms for the
soap dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom Outside of Building 3

Full Rec Relocate the soap dispenser in the restroom to a maximum Citation CBC 1115B.9.2; ADAAG A4.27
height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 518
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 298 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the controls and operating mechanisms for the
paper towel dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Men's Restroom Outside of Building 3

Full Rec Relocate the paper towel dispenser in the restroom to a Citation CBC 1115B.9.2; ADAAG A4.27
maximum height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 519
Priority:

Restrooms
Finding: There is no signage indicating accessibility on the latch side of
the entry door of the restroom. There is no Title 24 gender use
signage on the entrance door.

Alternative *
Rec:
(Where
Available)

Men's Showers Next to the Livestock Office

Full Rec The restroom is designated accessible and should be made Citation CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7));
accessible for the facility. Post signage centered 60 inches ADAAG 4.1.6(3)(e); ADAAG 4.30
above the ground surface on the latch side of the entrance door
identifying the restroom as accessible upon completion of the Minimum Quantity 1
following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG Maximum Quantity: 1
4.1.6(3)(e). Signage shall include Braille and raised lettering,
the gender or unisex use symbol and the ISA symbol. Post Title Unit: Each
24 gender use signage on the door @ 60" o.c. a.f.f. Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 714
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 299 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The bottom 10 inches of the door does not provide a smooth,
uninterrupted surface, or panel to allow the door to be opened
by a wheelchair footrest without creating a trap or hazardous
condition, due to the door stop.

Alternative *
Rec:
(Where
Available)

Men's Showers Next to the Livestock Office

Full Rec Install a panel or replace the door to provide a smooth, Citation CBC 1133B.2.6
uninterrupted surface for the bottom 10 inches of the door.

Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 715
Priority:

Restrooms
Finding: The height of the urinal rim in the restroom is greater than 17
inches above the finished floor.

Alternative *
Rec:
(Where
Available)

Men's Showers Next to the Livestock Office

Full Rec Lower the urinal designated to be accessible in the restroom so Citation ADAAG 4.18.2
that the rim height is not more than 17 inches above the finished
floor.
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1097
Maximum Estimated Cost: 1097
Record Number 716
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 300 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the urinal flush control in the restroom is greater
than 44 inches above the finished floor.

Alternative *
Rec:
(Where
Available)

Men's Showers Next to the Livestock Office

Full Rec Lower the flush control valve on the urinal designated to be Citation ADAAG 4.18.4
accessible in the restroom to a height not greater than 44 inches
above the finished floor (see ADAAG 4.18.4).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 951
Maximum Estimated Cost: 951
Record Number 717
Priority:

Restrooms
Finding: There is insufficient clear floor space in the stall designated to
be accessible in the restroom.

Alternative *
Rec:
(Where
Available)

Men's Showers Next to the Livestock Office

Full Rec Modify or replace the stall designated to be accessible in the Citation CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
restroom so that it complies with ADAAG 4.17.3, CBC 1115B
and CBC Figures 11B-1A and 1B. Standard accessible stalls
require 60 inches in width with 56 inches depth for wall-mounted Minimum Quantity 1
toilets or 59 inches depth for floor-mounted toilets to Maximum Quantity: 1
accommodate individuals in wheelchairs. The minimum width of
a front-approach doorway shall provide at least 32 inches and a Unit: Each
side-approach doorway shall provide at least 34 inches. The Minimum Estimated Cost: 4000
door shall swing outward, close automatically and provide
accessible hardware. Maximum Estimated Cost: 4000
Record Number 718
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 301 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: There are no grab bars in the stall designated to be accessible
in the restroom.

Alternative *
Rec:
(Where
Available)

Men's Showers Next to the Livestock Office

Full Rec Install one 36-inch back grab bar and one 42/48-inch side grab Citation CBC 1115B.8; ADAAG 4.26
bar in the stall designated to be accessible in the restroom.
Grab bars shall be mounted at a height of 33 inches above the
finished floor. Grab bars must be able to support a point load of Minimum Quantity 1
at least 250 pounds and shall be less than the allowable shear Maximum Quantity: 1
stress of the grab bar material.
Unit: Each
Minimum Estimated Cost: 531
Maximum Estimated Cost: 531
Record Number 719
Priority:

Restrooms
Finding: The flush control on the toilet in the stall designated to be
accessible in the restroom is not on the wide (approach) side of
the toilet.

Alternative *
Rec:
(Where
Available)

Men's Showers Next to the Livestock Office

Full Rec Relocate the flush control on the toilet in the stall designated to Citation ADAAG 4.16.5; ADAAG 4.27.4
be accessible in the restroom so that it is on the wide
(approach) side of the toilet area (see ADAAG 4.16.5). Flush
controls shall be hand-operated or automatic mechanisms. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 127
Maximum Estimated Cost: 127
Record Number 720
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 302 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the toilet seat in the stall designated to be
accessible in the restroom is less than 17 inches above the
finished floor.

Alternative *
Rec:
(Where
Available)

Men's Showers Next to the Livestock Office

Full Rec Remove or modify the toilet in the stall designated to be Citation ADAAG 4.16.3
accessible in the restroom so that the seat height is between 17
inches and 19 inches above the finished floor (see ADAAG
4.16.3). Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1707
Maximum Estimated Cost: 1707
Record Number 721
Priority:

Restrooms
Finding: The distance from the center of the toilet to the nearest side
wall in the stall designated to be accessible in the restroom is
less than 18 inches.

Alternative *
Rec:
(Where
Available)

Men's Showers Next to the Livestock Office

Full Rec Relocate the toilet or stall side wall so that the distance from the Citation CBC 1115B.7.1.3 ADAAG 4.17.3
centerline of the toilet to the nearest side wall in the stall
designated to be accessible in the restroom is exactly 18 inches
(see ADAAG Figure 28. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1143
Maximum Estimated Cost: 1143
Record Number 722
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 303 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The faucet controls on the lavatory in the restroom require tight
grasping, pinching, or twisting of the wrist and are not
accessible.

Alternative *
Rec:
(Where
Available)

Men's Showers Next to the Livestock Office

Full Rec Install faucet controls complying with ADAAG 4.19.5 on the Citation ADAAG 4.19.5
lavatory designated to be accessible in the restroom. Lever-
operated, push-type, touch-type or electronically controlled
mechanisms are acceptable elements (see ADAAG 4.19.5). If Minimum Quantity 1
self-closing valves are used the faucet shall remain open for at Maximum Quantity: 1
least 10 seconds.
Unit: Each
Minimum Estimated Cost: 392
Maximum Estimated Cost: 392
Record Number 723
Priority:

Restrooms
Finding: The knee clearance space under the lavatory designated to be
accessible in the restroom is less than 29 inches. The knee
depth space under the lavatory designated to be accessible in
the restroom is less than 27 inches at 8 inches under the
lavatory apron.

Alternative *
Rec:
(Where
Available)

Men's Showers Next to the Livestock Office

Full Rec Replace the lavatory designated to be accessible in the Citation ADAAG 4.19.2
restroom to provide at least 29 inches of clear knee space
between the finished floor and bottom of the lavatory apron.
Make sure to provide at least 27 inches at 8 inches under the Minimum Quantity 1
apron (see ADAAG 4.19.2). Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1286
Maximum Estimated Cost: 1286
Record Number 724
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 304 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The pipes under the lavatory in the restroom do not provide
protection against contact.

Alternative *
Rec:
(Where
Available)

Men's Showers Next to the Livestock Office

Full Rec Insulate or otherwise configure pipes under the lavatory Citation ADAAG 4.19.4
designated to be accessible in the restroom to protect against
contact (see ADAAG 4.19.4). Make certain there are no sharp
or abrasive surfaces under the lavatory. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 39
Maximum Estimated Cost: 39
Record Number 725
Priority:

Restrooms
Finding: The bottom edge of the reflecting surface of the mirror in the
restroom is greater than 40 inches above the finished floor.

Alternative *
Rec:
(Where
Available)

Men's Showers Next to the Livestock Office

Full Rec Lower the mirror in the restroom so that the bottom edge of the Citation ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG
reflecting surface is no higher than 40 inches above the finished 4.19.6
floor and the topmost portion of the reflecting surface extends at
least 74 inches above the finished floor (see ADAAG A4.19.6). Minimum Quantity 1
A single, full-length mirror is recommended since it can Maximum Quantity: 1
accommodate all people. Make certain to provide a minimum
clear floor space in front of the mirror of 30 inches in width and Unit: Each
48 inches in length. Minimum Estimated Cost: 291
Maximum Estimated Cost: 291
Record Number 726
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 305 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the controls and operating mechanisms for the
soap dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Men's Showers Next to the Livestock Office

Full Rec Relocate the soap dispenser in the restroom to a maximum Citation CBC 1115B.9.2; ADAAG A4.27
height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 727
Priority:

Restrooms
Finding: The height of the controls and operating mechanisms for the
paper towel dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Men's Showers Next to the Livestock Office

Full Rec Relocate the paper towel dispenser in the restroom to a Citation CBC 1115B.9.2; ADAAG A4.27
maximum height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 728
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 306 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: There are no accessible showers provided.

Alternative *
Rec:
(Where
Available)

Men's Showers Next to the Livestock Office

Full Rec Since open showers are provided in the restroom, at least one Citation CBC 1115B.6.3; ADAAG 4.21
accessible shower is required. Install an accessible shower in
one of the corners with L-shaped grab bars extending along the
two walls with a folding seat adjacent to the shower controls in Minimum Quantity 1
the restroom (see CBC 1115B.6.3 and ADAAG 4.21). Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 3260
Maximum Estimated Cost: 3260
Record Number 729
Priority:

Restrooms
Finding: There is no signage indicating accessibility on the latch side of
the entry door of the restroom. There is no Title 24 gender use
signage on the entrance door.

Alternative *
Rec:
(Where
Available)

Unisex Restroom at Building 6

Full Rec The restroom is designated accessible and should be made Citation CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7));
accessible for the facility. Post signage centered 60 inches ADAAG 4.1.6(3)(e); ADAAG 4.30
above the ground surface on the latch side of the entrance door
identifying the restroom as accessible upon completion of the Minimum Quantity 1
following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG Maximum Quantity: 1
4.1.6(3)(e). Signage shall include Braille and raised lettering,
the gender or unisex use symbol and the ISA symbol. Post Title Unit: Each
24 gender use signage on the door @ 60" o.c. a.f.f. Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 947
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 307 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The clear opening width of the entrance doorway to the
restroom is less than 32 inches.

Alternative *
Rec:
(Where
Available)

Unisex Restroom at Building 6

Full Rec Widen the entrance doorway to the restroom to provide a clear Citation ADAAG 4.13.5
opening width of at least 32 inches when the door is open 90
degrees (see ADAAG 4.13.5).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 750
Maximum Estimated Cost: 750
Record Number 948
Priority:

Restrooms
Finding: The entrance door to the restroom has a round doorknob that
requires tight grasping or twisting of the wrist to operate.

Alternative *
Rec:
(Where
Available)

Unisex Restroom at Building 6

Full Rec Replace the door hardware mounted on the restroom complying Citation ADAAG 4.13.9
with ADAAG 4.13.9. Make certain accessible door hardware is
mounted no higher than 48 inches above the finished floor.
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 204
Maximum Estimated Cost: 204
Record Number 949
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 308 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the threshold at the entrance door to the restroom
is greater than 1/2 inch.

Alternative *
Rec:
(Where
Available)

Unisex Restroom at Building 6

Full Rec Install a ramp or threshold treatment ramp with a slope no Citation ADAAG 4.1.6(3)(d)(ii); ADAAG 4.5.2
greater than 8.33% to the entrance of the restroom complying
with CBC 1133B.5 and ADAAG 4.8 when technically infeasible
to modify the threshold. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 2500
Maximum Estimated Cost: 2500
Record Number 950
Priority:

Restrooms
Finding: This restroom is not accessible and cannot be easily altered.
There is not sufficient clear floor space in the restroom to
accommodate an individual in a wheelchair.

Alternative *
Rec:
(Where
Available)

Unisex Restroom at Building 6

Full Rec Consult a design professional to modify the restroom. One or Citation CBC 1115B.7.2; ADAAG 4.16.2
more walls may need to be moved to provide sufficient clear
floor space to inscribe a 60-inch diameter turning radius in the
restroom to accommodate an individual in a wheelchair. Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 951
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 309 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: There are no grab bars in the restroom.

Alternative *
Rec:
(Where
Available)

Unisex Restroom at Building 6

Full Rec Install one 36-inch back grab bar and one 42/48-inch side grab Citation CBC 1115B.8; ADAAG 4.17.6; ADAAG 4.26.3
bar in the restroom. Grab bars shall be mounted at a height of
33 inches above the finished floor. Grab bars must be able to
support a point load of at least 250 pounds and shall be less Minimum Quantity 1
than the allowable shear stress of the grab bar material. Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 531
Maximum Estimated Cost: 531
Record Number 952
Priority:

Restrooms
Finding: The height of the toilet seat in the restroom is less than 17
inches above the finished floor.

Alternative *
Rec:
(Where
Available)

Unisex Restroom at Building 6

Full Rec Remove or modify the toilet in the restroom so that the seat Citation ADAAG 4.16.3
height is between 17 inches and 19 inches above the finished
floor (see ADAAG 4.16.3).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1707
Maximum Estimated Cost: 1707
Record Number 954
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 310 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The distance from the center of the toilet to the nearest side
wall in the restroom is less than 18 inches.

Alternative *
Rec:
(Where
Available)

Unisex Restroom at Building 6

Full Rec Relocate the toilet so that the distance from the centerline of the Citation CBC 1115B.7.1.3 ADAAG 4.17.3
toilet to the nearest side wall in the restroom is exactly 18
inches (see ADAAG Figure 28.
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1143
Maximum Estimated Cost: 1143
Record Number 955
Priority:

Restrooms
Finding: The seat cover dispenser in the restroom is mounted at a height
greater than 40 inches and there is no clear floor space.

Alternative *
Rec:
(Where
Available)

Unisex Restroom at Building 6

Full Rec Relocate the seat cover dispenser in the restroom so that the Citation CBC 1115B.9.2
height is no greater than 40 inches above the finished floor (see
CBC 1115B.9.2). Make certain that the location of the seat
cover dispenser does not interfere with the use of a grab bar Minimum Quantity 1
and provides sufficient clear floor space. Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 956
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 311 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The lavatory in the restroom is in an enclosed cabinet, thereby
preventing an accessible forward approach. The knee
clearance space under the lavatory designated to be accessible
in the restroom is less than 29 inches. The knee depth space
under the lavatory designated to be accessible in the restroom
is less than 27 inches at 8 inches under the lavatory apron.

Alternative *
Rec:
(Where
Available)

Unisex Restroom at Building 6

Full Rec Lavatories in restrooms must provide clear floor space in front of Citation ADAAG 4.19.2
the lavatory for an accessible forward approach and shall
provide at least 29 inches clear knee space and a minimum of
nine inches clear toe space (see ADAAG 4.19.2). If neither Minimum Quantity 1
clear floor space and knee and toe clearance can be provided, Maximum Quantity: 1
remove the lavatory cabinet and replace with an accessible wall-
mounted lavatory unit. Unit: Each
Minimum Estimated Cost: 420
Maximum Estimated Cost: 420
Record Number 957
Priority:

Restrooms
Finding: The faucet controls on the lavatory in the restroom require tight
grasping, pinching, or twisting of the wrist and are not
accessible.

Alternative *
Rec:
(Where
Available)

Unisex Restroom at Building 6

Full Rec Install faucet controls complying with ADAAG 4.19.5 on the Citation ADAAG 4.19.5
lavatory designated to be accessible in the restroom. Lever-
operated, push-type, touch-type or electronically controlled
mechanisms are acceptable elements (see ADAAG 4.19.5). If Minimum Quantity 1
self-closing valves are used the faucet shall remain open for at Maximum Quantity: 1
least 10 seconds.
Unit: Each
Minimum Estimated Cost: 392
Maximum Estimated Cost: 392
Record Number 958
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 312 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The pipes under the lavatory in the restroom do not provide
protection against contact.

Alternative *
Rec:
(Where
Available)

Unisex Restroom at Building 6

Full Rec Insulate or otherwise configure pipes under the lavatory Citation ADAAG 4.19.4
designated to be accessible in the restroom to protect against
contact (see ADAAG 4.19.4). Make certain there are no sharp
or abrasive surfaces under the lavatory. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 39
Maximum Estimated Cost: 39
Record Number 959
Priority:

Restrooms
Finding: The height of the controls and operating mechanisms for the
paper towel dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Unisex Restroom at Building 6

Full Rec Relocate the paper towel dispenser in the restroom to a Citation CBC 1115B.9.2; ADAAG A4.27
maximum height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 960
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 313 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: There is no signage indicating accessibility on the latch side of
the entry door of the restroom. There is no Title 24 gender use
signage on the entrance door.

Alternative *
Rec:
(Where
Available)

Unisex Restroom at Building 7

Full Rec The restroom is designated accessible and should be made Citation CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7));
accessible for the facility. Post signage centered 60 inches ADAAG 4.1.6(3)(e); ADAAG 4.30
above the ground surface on the latch side of the entrance door
identifying the restroom as accessible upon completion of the Minimum Quantity 1
following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG Maximum Quantity: 1
4.1.6(3)(e). Signage shall include Braille and raised lettering,
the gender or unisex use symbol and the ISA symbol. Post Title Unit: Each
24 gender use signage on the door @ 60" o.c. a.f.f. Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 677
Priority:

Restrooms
Finding: The height of the side grab bar in the restroom is greater than
33 inches above the finished floor.

Alternative *
Rec:
(Where
Available)

Unisex Restroom at Building 7

Full Rec Remount the side grab bar in the restroom so that the height of Citation CBC 1115B.8.1; ADAAG 4.26
the gripping surface is centered at 33 inches above the finished
floor. Grab bars must be able to support a point load of at least
250 pounds and shall be less than the allowable shear stress of Minimum Quantity 1
the grab bar material. Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 448
Maximum Estimated Cost: 448
Record Number 678
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 314 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The side grab bar in the restroom does not extend 54 inches
from the back wall.

Alternative *
Rec:
(Where
Available)

Unisex Restroom at Building 7

Full Rec The front end of the grab bar shall extend at least 54 inches Citation CBC 1115B.8.1; ADAAG 4.26
from the back wall and the back end of the grab bar shall be
mounted within 12 inches from the back wall. Grab bars must
be able to support a point load of at least 250 pounds and shall Minimum Quantity 1
be less than the allowable shear stress of the grab bar material. Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 531
Maximum Estimated Cost: 531
Record Number 679
Priority:

Restrooms
Finding: The flush control on the toilet in the restroom is not on the wide
(approach) side of the toilet.

Alternative *
Rec:
(Where
Available)

Unisex Restroom at Building 7

Full Rec Relocate the flush control on the toilet in the restroom so that it Citation ADAAG 4.16.5; ADAAG 4.27.4
is on the wide (approach) side of the toilet area (see ADAAG
4.16.5). Flush controls shall be hand-operated or automatic
mechanisms. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 127
Maximum Estimated Cost: 127
Record Number 680
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 315 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the toilet seat in the restroom is greater than 19
inches above the finished floor.

Alternative *
Rec:
(Where
Available)

Unisex Restroom at Building 7

Full Rec Remove or modify the toilet in the restroom so that the seat Citation ADAAG 4.16.3
height is between 17 inches and 19 inches above the finished
floor (see ADAAG 4.16.3).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1707
Maximum Estimated Cost: 1707
Record Number 681
Priority:

Restrooms
Finding: The distance from the center of the toilet to the nearest side
wall in the restroom is greater than 18 inches.

Alternative *
Rec:
(Where
Available)

Unisex Restroom at Building 7

Full Rec Relocate the toilet so that the distance from the centerline of the Citation CBC 1115B.7.1.3 ADAAG 4.17.3
toilet to the nearest side wall in the restroom is exactly 18
inches (see ADAAG Figure 28.
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1143
Maximum Estimated Cost: 1143
Record Number 682
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 316 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The seat cover dispenser in the restroom is mounted at a height
greater than 40 inches and there is no clear floor space.

Alternative *
Rec:
(Where
Available)

Unisex Restroom at Building 7

Full Rec Relocate the seat cover dispenser in the restroom so that the Citation CBC 1115B.9.2
height is no greater than 40 inches above the finished floor (see
CBC 1115B.9.2). Make certain that the location of the seat
cover dispenser does not interfere with the use of a grab bar Minimum Quantity 1
and provides sufficient clear floor space. Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 683
Priority:

Restrooms
Finding: The pipes under the lavatory in the restroom do not provide
protection against contact.

Alternative *
Rec:
(Where
Available)

Unisex Restroom at Building 7

Full Rec Insulate or otherwise configure pipes under the lavatory Citation ADAAG 4.19.4
designated to be accessible in the restroom to protect against
contact (see ADAAG 4.19.4). Make certain there are no sharp
or abrasive surfaces under the lavatory. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 39
Maximum Estimated Cost: 39
Record Number 684
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 317 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the controls and operating mechanisms for the
soap dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Unisex Restroom at Building 7

Full Rec Relocate the soap dispenser in the restroom to a maximum Citation CBC 1115B.9.2; ADAAG A4.27
height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 685
Priority:

Restrooms
Finding: The height of the controls and operating mechanisms for the
paper towel dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Unisex Restroom at Building 7

Full Rec Relocate the paper towel dispenser in the restroom to a Citation CBC 1115B.9.2; ADAAG A4.27
maximum height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 686
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 318 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: There is no signage indicating accessibility on the latch side of
the entry door of the restroom. There is no Title 24 gender use
signage on the entrance door.

Alternative *
Rec:
(Where
Available)

Unisex Restroom at Building 8

Full Rec The restroom is designated accessible and should be made Citation CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7));
accessible for the facility. Post signage centered 60 inches ADAAG 4.1.6(3)(e); ADAAG 4.30
above the ground surface on the latch side of the entrance door
identifying the restroom as accessible upon completion of the Minimum Quantity 1
following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG Maximum Quantity: 1
4.1.6(3)(e). Signage shall include Braille and raised lettering,
the gender or unisex use symbol and the ISA symbol. Post Title Unit: Each
24 gender use signage on the door @ 60" o.c. a.f.f. Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 665
Priority:

Restrooms
Finding: The clear opening width of the entrance doorway to the
restroom is less than 32 inches.

Alternative *
Rec:
(Where
Available)

Unisex Restroom at Building 8

Full Rec Widen the entrance doorway to the restroom to provide a clear Citation ADAAG 4.13.5
opening width of at least 32 inches when the door is open 90
degrees (see ADAAG 4.13.5).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 750
Maximum Estimated Cost: 750
Record Number 666
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 319 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The entrance door to the restroom has a round doorknob that
requires tight grasping or twisting of the wrist to operate.

Alternative *
Rec:
(Where
Available)

Unisex Restroom at Building 8

Full Rec Replace the door hardware mounted on the restroom complying Citation ADAAG 4.13.9
with ADAAG 4.13.9. Make certain accessible door hardware is
mounted no higher than 48 inches above the finished floor.
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 204
Maximum Estimated Cost: 204
Record Number 667
Priority:

Restrooms
Finding: This restroom is not accessible and cannot be easily altered.
There is not sufficient clear floor space in the restroom to
accommodate an individual in a wheelchair.

Alternative *
Rec:
(Where
Available)

Unisex Restroom at Building 8

Full Rec Consult a design professional to modify the restroom. One or Citation CBC 1115B.7.2; ADAAG 4.16.2
more walls may need to be moved to provide sufficient clear
floor space to inscribe a 60-inch diameter turning radius in the
restroom to accommodate an individual in a wheelchair. Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 668
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 320 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: There are no grab bars in the restroom.

Alternative *
Rec:
(Where
Available)

Unisex Restroom at Building 8

Full Rec Install one 36-inch back grab bar and one 42/48-inch side grab Citation CBC 1115B.8; ADAAG 4.17.6; ADAAG 4.26.3
bar in the restroom. Grab bars shall be mounted at a height of
33 inches above the finished floor. Grab bars must be able to
support a point load of at least 250 pounds and shall be less Minimum Quantity 1
than the allowable shear stress of the grab bar material. Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 531
Maximum Estimated Cost: 531
Record Number 669
Priority:

Restrooms
Finding: The flush control on the toilet in the restroom is not on the wide
(approach) side of the toilet.

Alternative *
Rec:
(Where
Available)

Unisex Restroom at Building 8

Full Rec Relocate the flush control on the toilet in the restroom so that it Citation ADAAG 4.16.5; ADAAG 4.27.4
is on the wide (approach) side of the toilet area (see ADAAG
4.16.5). Flush controls shall be hand-operated or automatic
mechanisms. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 127
Maximum Estimated Cost: 127
Record Number 670
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 321 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The seat cover dispenser in the restroom is mounted at a height
greater than 40 inches and there is no clear floor space.

Alternative *
Rec:
(Where
Available)

Unisex Restroom at Building 8

Full Rec Relocate the seat cover dispenser in the restroom so that the Citation CBC 1115B.9.2
height is no greater than 40 inches above the finished floor (see
CBC 1115B.9.2). Make certain that the location of the seat
cover dispenser does not interfere with the use of a grab bar Minimum Quantity 1
and provides sufficient clear floor space. Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 671
Priority:

Restrooms
Finding: The faucet controls on the lavatory in the restroom require tight
grasping, pinching, or twisting of the wrist and are not
accessible.

Alternative *
Rec:
(Where
Available)

Unisex Restroom at Building 8

Full Rec Install faucet controls complying with ADAAG 4.19.5 on the Citation ADAAG 4.19.5
lavatory designated to be accessible in the restroom. Lever-
operated, push-type, touch-type or electronically controlled
mechanisms are acceptable elements (see ADAAG 4.19.5). If Minimum Quantity 1
self-closing valves are used the faucet shall remain open for at Maximum Quantity: 1
least 10 seconds.
Unit: Each
Minimum Estimated Cost: 392
Maximum Estimated Cost: 392
Record Number 672
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 322 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The knee clearance space under the lavatory designated to be
accessible in the restroom is less than 29 inches. The knee
depth space under the lavatory designated to be accessible in
the restroom is less than 27 inches at 8 inches under the
lavatory apron.

Alternative *
Rec:
(Where
Available)

Unisex Restroom at Building 8

Full Rec Replace the lavatory designated to be accessible in the Citation ADAAG 4.19.2
restroom to provide at least 29 inches of clear knee space
between the finished floor and bottom of the lavatory apron.
Make sure to provide at least 27 inches at 8 inches under the Minimum Quantity 1
apron (see ADAAG 4.19.2). Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1286
Maximum Estimated Cost: 1286
Record Number 673
Priority:

Restrooms
Finding: The pipes under the lavatory in the restroom do not provide
protection against contact.

Alternative *
Rec:
(Where
Available)

Unisex Restroom at Building 8

Full Rec Insulate or otherwise configure pipes under the lavatory Citation ADAAG 4.19.4
designated to be accessible in the restroom to protect against
contact (see ADAAG 4.19.4). Make certain there are no sharp
or abrasive surfaces under the lavatory. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 39
Maximum Estimated Cost: 39
Record Number 674
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 323 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the controls and operating mechanisms for the
soap dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Unisex Restroom at Building 8

Full Rec Relocate the soap dispenser in the restroom to a maximum Citation CBC 1115B.9.2; ADAAG A4.27
height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 675
Priority:

Restrooms
Finding: The height of the controls and operating mechanisms for the
paper towel dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Unisex Restroom at Building 8

Full Rec Relocate the paper towel dispenser in the restroom to a Citation CBC 1115B.9.2; ADAAG A4.27
maximum height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 676
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 324 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: There is no signage indicating accessibility on the latch side of
the entry door of the restroom. There is no Title 24 gender use
signage on the entrance door.

Alternative *
Rec:
(Where
Available)

Unisex Restroom at Building 8

Full Rec The restroom is designated accessible and should be made Citation CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7));
accessible for the facility. Post signage centered 60 inches ADAAG 4.1.6(3)(e); ADAAG 4.30
above the ground surface on the latch side of the entrance door
identifying the restroom as accessible upon completion of the Minimum Quantity 1
following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG Maximum Quantity: 1
4.1.6(3)(e). Signage shall include Braille and raised lettering,
the gender or unisex use symbol and the ISA symbol. Post Title Unit: Each
24 gender use signage on the door @ 60" o.c. a.f.f. Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 759
Priority:

Restrooms
Finding: The clear opening width of the entrance doorway to the
restroom is less than 32 inches.

Alternative *
Rec:
(Where
Available)

Unisex Restroom at Building 8

Full Rec Widen the entrance doorway to the restroom to provide a clear Citation ADAAG 4.13.5
opening width of at least 32 inches when the door is open 90
degrees (see ADAAG 4.13.5).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 750
Maximum Estimated Cost: 750
Record Number 760
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 325 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The entrance door to the restroom has a round doorknob that
requires tight grasping or twisting of the wrist to operate.

Alternative *
Rec:
(Where
Available)

Unisex Restroom at Building 8

Full Rec Replace the door hardware mounted on the restroom complying Citation ADAAG 4.13.9
with ADAAG 4.13.9. Make certain accessible door hardware is
mounted no higher than 48 inches above the finished floor.
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 204
Maximum Estimated Cost: 204
Record Number 761
Priority:

Restrooms
Finding: There is less than 18 inches on the latch side of the entrance
door to the restroom from the pull side.

Alternative *
Rec:
(Where
Available)

Unisex Restroom at Building 8

Full Rec Consult a design professional to determine if it is technically Citation ADAAG 4.13.6; CBC 1133B.2.4.2
feasible to provide at least 18 inches of latch side clearance at
the entrance door to the restroom from the pull side (see
ADAAG 4.13.6 and Figure 25). Otherwise, an automatic door Minimum Quantity 1
opening device may be required to provide an accessible Maximum Quantity: 1
entrance.
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 762
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 326 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: There are no grab bars in the restroom.

Alternative *
Rec:
(Where
Available)

Unisex Restroom at Building 8

Full Rec Install one 36-inch back grab bar and one 42/48-inch side grab Citation CBC 1115B.8; ADAAG 4.17.6; ADAAG 4.26.3
bar in the restroom. Grab bars shall be mounted at a height of
33 inches above the finished floor. Grab bars must be able to
support a point load of at least 250 pounds and shall be less Minimum Quantity 1
than the allowable shear stress of the grab bar material. Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 531
Maximum Estimated Cost: 531
Record Number 763
Priority:

Restrooms
Finding: The distance from the center of the toilet to the nearest side
wall in the restroom is less than 18 inches.

Alternative *
Rec:
(Where
Available)

Unisex Restroom at Building 8

Full Rec Relocate the toilet so that the distance from the centerline of the Citation CBC 1115B.7.1.3 ADAAG 4.17.3
toilet to the nearest side wall in the restroom is exactly 18
inches (see ADAAG Figure 28.
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1143
Maximum Estimated Cost: 1143
Record Number 765
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 327 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The seat cover dispenser in the restroom is mounted at a height
greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Unisex Restroom at Building 8

Full Rec Relocate the seat cover dispenser in the restroom so that the Citation CBC 1115B.9.2
height is no greater than 40 inches above the finished floor (see
CBC 1115B.9.2). Make certain that the location of the seat
cover dispenser does not interfere with the use of a grab bar Minimum Quantity 1
and provides sufficient clear floor space. Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 766
Priority:

Restrooms
Finding: The faucet controls on the lavatory in the restroom require tight
grasping, pinching, or twisting of the wrist and are not
accessible.

Alternative *
Rec:
(Where
Available)

Unisex Restroom at Building 8

Full Rec Install faucet controls complying with ADAAG 4.19.5 on the Citation ADAAG 4.19.5
lavatory designated to be accessible in the restroom. Lever-
operated, push-type, touch-type or electronically controlled
mechanisms are acceptable elements (see ADAAG 4.19.5). If Minimum Quantity 1
self-closing valves are used the faucet shall remain open for at Maximum Quantity: 1
least 10 seconds.
Unit: Each
Minimum Estimated Cost: 392
Maximum Estimated Cost: 392
Record Number 767
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 328 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The knee clearance space under the lavatory designated to be
accessible in the restroom is less than 29 inches. The knee
depth space under the lavatory designated to be accessible in
the restroom is less than 27 inches at 8 inches under the
lavatory apron.

Alternative *
Rec:
(Where
Available)

Unisex Restroom at Building 8

Full Rec Replace the lavatory designated to be accessible in the Citation ADAAG 4.19.2
restroom to provide at least 29 inches of clear knee space
between the finished floor and bottom of the lavatory apron.
Make sure to provide at least 27 inches at 8 inches under the Minimum Quantity 1
apron (see ADAAG 4.19.2). Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1286
Maximum Estimated Cost: 1286
Record Number 768
Priority:

Restrooms
Finding: The pipes under the lavatory in the restroom do not provide
protection against contact.

Alternative *
Rec:
(Where
Available)

Unisex Restroom at Building 8

Full Rec Insulate or otherwise configure pipes under the lavatory Citation ADAAG 4.19.4
designated to be accessible in the restroom to protect against
contact (see ADAAG 4.19.4). Make certain there are no sharp
or abrasive surfaces under the lavatory. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 39
Maximum Estimated Cost: 39
Record Number 769
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 329 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The bottom edge of the reflecting surface of the mirror in the
restroom is greater than 40 inches above the finished floor.

Alternative *
Rec:
(Where
Available)

Unisex Restroom at Building 8

Full Rec Lower the mirror in the restroom so that the bottom edge of the Citation ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG
reflecting surface is no higher than 40 inches above the finished 4.19.6
floor and the topmost portion of the reflecting surface extends at
least 74 inches above the finished floor (see ADAAG A4.19.6). Minimum Quantity 1
A single, full-length mirror is recommended since it can Maximum Quantity: 1
accommodate all people. Make certain to provide a minimum
clear floor space in front of the mirror of 30 inches in width and Unit: Each
48 inches in length. Minimum Estimated Cost: 291
Maximum Estimated Cost: 291
Record Number 770
Priority:

Restrooms
Finding: The height of the controls and operating mechanisms for the
soap dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Unisex Restroom at Building 8

Full Rec Relocate the soap dispenser in the restroom to a maximum Citation CBC 1115B.9.2; ADAAG A4.27
height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 771
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 330 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the controls and operating mechanisms for the
paper towel dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Unisex Restroom at Building 8

Full Rec Relocate the paper towel dispenser in the restroom to a Citation CBC 1115B.9.2; ADAAG A4.27
maximum height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 772
Priority:

Restrooms
Finding: The signage on the latch side of the entry door of the restroom
does not include the International Symbol of Accessibility and is
not centered at 60 inches above the floor surface. There is no
Title 24 gender use signage on the entrance door.

Alternative *
Rec:
(Where
Available)

Unisex Restroom at the First Aid Building

Full Rec The restroom is designated accessible and should be made Citation CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7));
accessible for the facility. Post signage centered 60 inches ADAAG 4.1.6(3)(e); ADAAG 4.30
above the ground surface on the latch side of the entrance door
identifying the restroom as accessible upon completion of the Minimum Quantity 1
following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG Maximum Quantity: 1
4.1.6(3)(e). Signage shall include Braille and raised lettering,
the gender or unisex use symbol and the ISA symbol. Post Title Unit: Each
24 gender use signage on the door @ 60" o.c. a.f.f. Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 609
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 331 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: There is less than 48 inches of clear floor space provided in
front of the water closet in the restroom to allow an accessible
forward approach.

Alternative *
Rec:
(Where
Available)

Unisex Restroom at the First Aid Building

Full Rec The minimum clear floor space in front of the water closet Citation CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
designated to be accessible in the restroom shall be at least 30
inches by 48 inches to provide an accessible forward approach.
Consult a design professional to determine if elements or walls Minimum Quantity 1
need to be removed to provide sufficient clear floor space in Maximum Quantity: 1
front of the water closet.
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 610
Priority:

Restrooms
Finding: The height of the side grab bar in the restroom is greater than
33 inches above the finished floor.

Alternative *
Rec:
(Where
Available)

Unisex Restroom at the First Aid Building

Full Rec Remount the side grab bar in the restroom so that the height of Citation CBC 1115B.8.1; ADAAG 4.26
the gripping surface is centered at 33 inches above the finished
floor. Grab bars must be able to support a point load of at least
250 pounds and shall be less than the allowable shear stress of Minimum Quantity 1
the grab bar material. Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 448
Maximum Estimated Cost: 448
Record Number 611
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 332 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The distance from the end of the back grab bar to the nearest
side wall in the restroom is greater than 6 inches.

Alternative *
Rec:
(Where
Available)

Unisex Restroom at the First Aid Building

Full Rec Remount the back grab bar in the restroom so that it is not more Citation ADAAG 4.26; CBC 1115B.8.1
than 6 inches from the nearest side wall (see ADAAG 4.26 and
CBC Figure 11B.1A-1C). Grab bars must be able to support a
point load of at least 250 pounds and shall be less than the Minimum Quantity 1
allowable shear stress of the grab bar material. Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 448
Maximum Estimated Cost: 448
Record Number 612
Priority:

Restrooms
Finding: The knee clearance space under the lavatory designated to be
accessible in the restroom is less than 29 inches. The knee
depth space under the lavatory designated to be accessible in
the restroom is less than 27 inches at 8 inches under the
lavatory apron.

Alternative *
Rec:
(Where
Available)

Unisex Restroom at the First Aid Building

Full Rec Replace the lavatory designated to be accessible in the Citation ADAAG 4.19.2
restroom to provide at least 29 inches of clear knee space
between the finished floor and bottom of the lavatory apron.
Make sure to provide at least 27 inches at 8 inches under the Minimum Quantity 1
apron (see ADAAG 4.19.2). Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1286
Maximum Estimated Cost: 1286
Record Number 613
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 333 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the controls and operating mechanisms for the
paper towel dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Unisex Restroom at the First Aid Building

Full Rec Relocate the paper towel dispenser in the restroom to a Citation CBC 1115B.9.2; ADAAG A4.27
maximum height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 614
Priority:

Restrooms
Finding: There is no signage indicating accessibility on the latch side of
the entry door of the restroom. There is no Title 24 gender use
signage on the entrance door.

Alternative *
Rec:
(Where
Available)

Unisex Restroom at the Jockey's Quarters

Full Rec The restroom is designated accessible and should be made Citation CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7));
accessible for the facility. Post signage centered 60 inches ADAAG 4.1.6(3)(e); ADAAG 4.30
above the ground surface on the latch side of the entrance door
identifying the restroom as accessible upon completion of the Minimum Quantity 1
following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG Maximum Quantity: 1
4.1.6(3)(e). Signage shall include Braille and raised lettering,
the gender or unisex use symbol and the ISA symbol. Post Title Unit: Each
24 gender use signage on the door @ 60" o.c. a.f.f. Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 1030
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 334 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: There is insufficient clear floor space in the stall designated to
be accessible in the restroom. The stall door to the stall
designated to be accessible in the restroom swings inward
limiting the clear floor space in the stall designated to be
accessible. The door to the stall designated to be accessible in
the restroom does not close automatically or have accessible
hardware.

Alternative *
Rec:
(Where
Available)

Unisex Restroom at the Jockey's Quarters

Full Rec Modify or replace the stall designated to be accessible in the Citation CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
restroom so that it complies with ADAAG 4.17.3, CBC 1115B
and CBC Figures 11B-1A and 1B. Standard accessible stalls
require 60 inches in width with 56 inches depth for wall-mounted Minimum Quantity 1
toilets or 59 inches depth for floor-mounted toilets to Maximum Quantity: 1
accommodate individuals in wheelchairs. The minimum width of
a front-approach doorway shall provide at least 32 inches and a Unit: Each
side-approach doorway shall provide at least 34 inches. The Minimum Estimated Cost: 4000
door shall swing outward, close automatically and provide
accessible hardware. Maximum Estimated Cost: 4000
Record Number 1031
Priority:

Restrooms
Finding: There are no grab bars in the stall designated to be accessible
in the restroom.

Alternative *
Rec:
(Where
Available)

Unisex Restroom at the Jockey's Quarters

Full Rec Install one 36-inch back grab bar and one 42/48-inch side grab Citation CBC 1115B.8; ADAAG 4.26
bar in the stall designated to be accessible in the restroom.
Grab bars shall be mounted at a height of 33 inches above the
finished floor. Grab bars must be able to support a point load of Minimum Quantity 1
at least 250 pounds and shall be less than the allowable shear Maximum Quantity: 1
stress of the grab bar material.
Unit: Each
Minimum Estimated Cost: 531
Maximum Estimated Cost: 531
Record Number 1032
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 335 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The flush control on the toilet in the stall designated to be
accessible in the restroom is not on the wide (approach) side of
the toilet.

Alternative *
Rec:
(Where
Available)

Unisex Restroom at the Jockey's Quarters

Full Rec Relocate the flush control on the toilet in the stall designated to Citation ADAAG 4.16.5; ADAAG 4.27.4
be accessible in the restroom so that it is on the wide
(approach) side of the toilet area (see ADAAG 4.16.5). Flush
controls shall be hand-operated or automatic mechanisms. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 127
Maximum Estimated Cost: 127
Record Number 1034
Priority:

Restrooms
Finding: The height of the toilet seat in the stall designated to be
accessible in the restroom is less than 17 inches above the
finished floor.

Alternative *
Rec:
(Where
Available)

Unisex Restroom at the Jockey's Quarters

Full Rec Remove or modify the toilet in the stall designated to be Citation ADAAG 4.16.3
accessible in the restroom so that the seat height is between 17
inches and 19 inches above the finished floor (see ADAAG
4.16.3). Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1707
Maximum Estimated Cost: 1707
Record Number 1035
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 336 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The distance from the center of the toilet to the nearest side
wall in the stall designated to be accessible in the restroom is
less than 18 inches.

Alternative *
Rec:
(Where
Available)

Unisex Restroom at the Jockey's Quarters

Full Rec Relocate the toilet or stall side wall so that the distance from the Citation CBC 1115B.7.1.3 ADAAG 4.17.3
centerline of the toilet to the nearest side wall in the stall
designated to be accessible in the restroom is exactly 18 inches
(see ADAAG Figure 28. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1143
Maximum Estimated Cost: 1143
Record Number 1036
Priority:

Restrooms
Finding: The seat cover dispenser in the stall designated to be
accessible in the restroom is mounted at a height greater than
40 inches and there is no clear floor space.

Alternative *
Rec:
(Where
Available)

Unisex Restroom at the Jockey's Quarters

Full Rec Relocate the seat cover dispenser in the stall designated to be Citation CBC 1115B.9.2
accessible in the restroom so that the height is no greater than
40 inches above the finished floor (see CBC 1115B.9.2). Make
certain that the location of the seat cover dispenser does not Minimum Quantity 1
interfere with the use of a grab bar and provides sufficient clear Maximum Quantity: 1
floor space.
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 1037
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 337 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The knee clearance space under the lavatory designated to be
accessible in the restroom is less than 29 inches. The knee
depth space under the lavatory designated to be accessible in
the restroom is less than 27 inches at 8 inches under the
lavatory apron.

Alternative *
Rec:
(Where
Available)

Unisex Restroom at the Jockey's Quarters

Full Rec Replace the lavatory designated to be accessible in the Citation ADAAG 4.19.2
restroom to provide at least 29 inches of clear knee space
between the finished floor and bottom of the lavatory apron.
Make sure to provide at least 27 inches at 8 inches under the Minimum Quantity 1
apron (see ADAAG 4.19.2). Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1286
Maximum Estimated Cost: 1286
Record Number 1038
Priority:

Restrooms
Finding: The pipes under the lavatory in the restroom do not provide
protection against contact.

Alternative *
Rec:
(Where
Available)

Unisex Restroom at the Jockey's Quarters

Full Rec Insulate or otherwise configure pipes under the lavatory Citation ADAAG 4.19.4
designated to be accessible in the restroom to protect against
contact (see ADAAG 4.19.4). Make certain there are no sharp
or abrasive surfaces under the lavatory. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 39
Maximum Estimated Cost: 39
Record Number 1039
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 338 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The bottom edge of the reflecting surface of the mirror in the
restroom is greater than 40 inches above the finished floor.

Alternative *
Rec:
(Where
Available)

Unisex Restroom at the Jockey's Quarters

Full Rec Lower the mirror in the restroom so that the bottom edge of the Citation ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG
reflecting surface is no higher than 40 inches above the finished 4.19.6
floor and the topmost portion of the reflecting surface extends at
least 74 inches above the finished floor (see ADAAG A4.19.6). Minimum Quantity 1
A single, full-length mirror is recommended since it can Maximum Quantity: 1
accommodate all people. Make certain to provide a minimum
clear floor space in front of the mirror of 30 inches in width and Unit: Each
48 inches in length. Minimum Estimated Cost: 291
Maximum Estimated Cost: 291
Record Number 1040
Priority:

Restrooms
Finding: The height of the controls and operating mechanisms for the
soap dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Unisex Restroom at the Jockey's Quarters

Full Rec Relocate the soap dispenser in the restroom to a maximum Citation CBC 1115B.9.2; ADAAG A4.27
height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 1041
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 339 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the controls and operating mechanisms for the
paper towel dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Unisex Restroom at the Jockey's Quarters

Full Rec Relocate the paper towel dispenser in the restroom to a Citation CBC 1115B.9.2; ADAAG A4.27
maximum height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 1042
Priority:

Restrooms
Finding: There is no signage indicating accessibility on the latch side of
the entry door of the restroom. There is no Title 24 gender use
signage on the entrance door.

Alternative *
Rec:
(Where
Available)

Unisex Restroom at the Livestock Office

Full Rec The restroom is designated accessible and should be made Citation CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7));
accessible for the facility. Post signage centered 60 inches ADAAG 4.1.6(3)(e); ADAAG 4.30
above the ground surface on the latch side of the entrance door
identifying the restroom as accessible upon completion of the Minimum Quantity 1
following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG Maximum Quantity: 1
4.1.6(3)(e). Signage shall include Braille and raised lettering,
the gender or unisex use symbol and the ISA symbol. Post Title Unit: Each
24 gender use signage on the door @ 60" o.c. a.f.f. Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 790
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 340 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the side grab bar in the restroom is greater than
33 inches above the finished floor.

Alternative *
Rec:
(Where
Available)

Unisex Restroom at the Livestock Office

Full Rec Remount the side grab bar in the restroom so that the height of Citation CBC 1115B.8.1; ADAAG 4.26
the gripping surface is centered at 33 inches above the finished
floor. Grab bars must be able to support a point load of at least
250 pounds and shall be less than the allowable shear stress of Minimum Quantity 1
the grab bar material. Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 448
Maximum Estimated Cost: 448
Record Number 791
Priority:

Restrooms
Finding: The location of the toilet paper dispenser in the restroom is not
within 12 inches of the front edge of the toilet seat.
t.

Alternative *
Rec:
(Where
Available)

Unisex Restroom at the Livestock Office

Full Rec Remount the toilet paper dispenser in the restroom so that it is Citation CBC 1115B.9.3; ADAAG 4.16.6
within 12 inches from the front edge of the toilet seat and does
not encroach more than four inches from the face of the wall
(see CBC 1115B.9.3 and ADAAG Figure 29(b)). Toilet paper Minimum Quantity 1
dispensers must allow continuous paper flow and shall not Maximum Quantity: 1
interfere with the use of the side grab bar.
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 792
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 341 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The flush control on the toilet in the restroom is not on the wide
(approach) side of the toilet.

Alternative *
Rec:
(Where
Available)

Unisex Restroom at the Livestock Office

Full Rec Relocate the flush control on the toilet in the restroom so that it Citation ADAAG 4.16.5; ADAAG 4.27.4
is on the wide (approach) side of the toilet area (see ADAAG
4.16.5). Flush controls shall be hand-operated or automatic
mechanisms. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 127
Maximum Estimated Cost: 127
Record Number 793
Priority:

Restrooms
Finding: The distance from the center of the toilet to the nearest side
wall in the restroom is greater than 18 inches.

Alternative *
Rec:
(Where
Available)

Unisex Restroom at the Livestock Office

Full Rec Relocate the toilet so that the distance from the centerline of the Citation CBC 1115B.7.1.3 ADAAG 4.17.3
toilet to the nearest side wall in the restroom is exactly 18
inches (see ADAAG Figure 28.
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1143
Maximum Estimated Cost: 1143
Record Number 794
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 342 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The seat cover dispenser in the restroom is mounted at a height
greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Unisex Restroom at the Livestock Office

Full Rec Relocate the seat cover dispenser in the restroom so that the Citation CBC 1115B.9.2
height is no greater than 40 inches above the finished floor (see
CBC 1115B.9.2). Make certain that the location of the seat
cover dispenser does not interfere with the use of a grab bar Minimum Quantity 1
and provides sufficient clear floor space. Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 795
Priority:

Restrooms
Finding: The bottom edge of the reflecting surface of the mirror in the
restroom is greater than 40 inches above the finished floor.

Alternative *
Rec:
(Where
Available)

Unisex Restroom at the Livestock Office

Full Rec Lower the mirror in the restroom so that the bottom edge of the Citation ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG
reflecting surface is no higher than 40 inches above the finished 4.19.6
floor and the topmost portion of the reflecting surface extends at
least 74 inches above the finished floor (see ADAAG A4.19.6). Minimum Quantity 1
A single, full-length mirror is recommended since it can Maximum Quantity: 1
accommodate all people. Make certain to provide a minimum
clear floor space in front of the mirror of 30 inches in width and Unit: Each
48 inches in length. Minimum Estimated Cost: 291
Maximum Estimated Cost: 291
Record Number 796
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 343 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the controls and operating mechanisms for the
paper towel dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Unisex Restroom at the Livestock Office

Full Rec Relocate the paper towel dispenser in the restroom to a Citation CBC 1115B.9.2; ADAAG A4.27
maximum height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 797
Priority:

Restrooms
Finding: There is no signage indicating accessibility on the latch side of
the entry door of the restroom. The gender use signage on the
entrance door is not centered at 60 inches above the floor
surface.

Alternative *
Rec:
(Where
Available)

Unisex Restroom in the Stable Office

Full Rec The restroom is designated accessible and should be made Citation CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7));
accessible for the facility. Post signage centered 60 inches ADAAG 4.1.6(3)(e); ADAAG 4.30
above the ground surface on the latch side of the entrance door
identifying the restroom as accessible upon completion of the Minimum Quantity 1
following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG Maximum Quantity: 1
4.1.6(3)(e). Signage shall include Braille and raised lettering,
the gender or unisex use symbol and the ISA symbol. Post Title Unit: Each
24 gender use signage on the door @ 60" o.c. a.f.f. Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 442
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 344 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The clear opening width of the entrance doorway to the
restroom is less than 32 inches.

Alternative *
Rec:
(Where
Available)

Unisex Restroom in the Stable Office

Full Rec Widen the entrance doorway to the restroom to provide a clear Citation ADAAG 4.13.5
opening width of at least 32 inches when the door is open 90
degrees (see ADAAG 4.13.5).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 750
Maximum Estimated Cost: 750
Record Number 443
Priority:

Restrooms
Finding: There is insufficient clear floor space in the stall designated to
be accessible in the restroom. The door to the stall designated
to be accessible in the restroom does not close automatically or
have accessible hardware.

Alternative *
Rec:
(Where
Available)

Unisex Restroom in the Stable Office

Full Rec Modify or replace the stall designated to be accessible in the Citation CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
restroom so that it complies with ADAAG 4.17.3, CBC 1115B
and CBC Figures 11B-1A and 1B. Standard accessible stalls
require 60 inches in width with 56 inches depth for wall-mounted Minimum Quantity 1
toilets or 59 inches depth for floor-mounted toilets to Maximum Quantity: 1
accommodate individuals in wheelchairs. The minimum width of
a front-approach doorway shall provide at least 32 inches and a Unit: Each
side-approach doorway shall provide at least 34 inches. The Minimum Estimated Cost: 4000
door shall swing outward, close automatically and provide
accessible hardware. Maximum Estimated Cost: 4000
Record Number 444
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 345 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: There are no grab bars in the stall designated to be accessible
in the restroom.

Alternative *
Rec:
(Where
Available)

Unisex Restroom in the Stable Office

Full Rec Install one 36-inch back grab bar and one 42/48-inch side grab Citation CBC 1115B.8; ADAAG 4.26
bar in the stall designated to be accessible in the restroom.
Grab bars shall be mounted at a height of 33 inches above the
finished floor. Grab bars must be able to support a point load of Minimum Quantity 1
at least 250 pounds and shall be less than the allowable shear Maximum Quantity: 1
stress of the grab bar material.
Unit: Each
Minimum Estimated Cost: 531
Maximum Estimated Cost: 531
Record Number 445
Priority:

Restrooms
Finding: The flush control on the toilet in the stall designated to be
accessible in the restroom is not on the wide (approach) side of
the toilet.

Alternative *
Rec:
(Where
Available)

Unisex Restroom in the Stable Office

Full Rec Relocate the flush control on the toilet in the stall designated to Citation ADAAG 4.16.5; ADAAG 4.27.4
be accessible in the restroom so that it is on the wide
(approach) side of the toilet area (see ADAAG 4.16.5). Flush
controls shall be hand-operated or automatic mechanisms. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 127
Maximum Estimated Cost: 127
Record Number 446
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 346 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the toilet seat in the stall designated to be
accessible in the restroom is less than 17 inches above the
finished floor.

Alternative *
Rec:
(Where
Available)

Unisex Restroom in the Stable Office

Full Rec Remove or modify the toilet in the stall designated to be Citation ADAAG 4.16.3
accessible in the restroom so that the seat height is between 17
inches and 19 inches above the finished floor (see ADAAG
4.16.3). Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1707
Maximum Estimated Cost: 1707
Record Number 447
Priority:

Restrooms
Finding: The distance from the center of the toilet to the nearest side
wall in the stall designated to be accessible in the restroom is
less than 18 inches.

Alternative *
Rec:
(Where
Available)

Unisex Restroom in the Stable Office

Full Rec Relocate the toilet or stall side wall so that the distance from the Citation CBC 1115B.7.1.3 ADAAG 4.17.3
centerline of the toilet to the nearest side wall in the stall
designated to be accessible in the restroom is exactly 18 inches
(see ADAAG Figure 28. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1143
Maximum Estimated Cost: 1143
Record Number 448
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 347 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The seat cover dispenser in the stall designated to be
accessible in the restroom is mounted at a height greater than
40 inches and there is no clear floor space.

Alternative *
Rec:
(Where
Available)

Unisex Restroom in the Stable Office

Full Rec Relocate the seat cover dispenser in the stall designated to be Citation CBC 1115B.9.2
accessible in the restroom so that the height is no greater than
40 inches above the finished floor (see CBC 1115B.9.2). Make
certain that the location of the seat cover dispenser does not Minimum Quantity 1
interfere with the use of a grab bar and provides sufficient clear Maximum Quantity: 1
floor space.
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 449
Priority:

Restrooms
Finding: The faucet controls on the lavatory in the restroom require tight
grasping, pinching, or twisting of the wrist and are not
accessible.

Alternative *
Rec:
(Where
Available)

Unisex Restroom in the Stable Office

Full Rec Install faucet controls complying with ADAAG 4.19.5 on the Citation ADAAG 4.19.5
lavatory designated to be accessible in the restroom. Lever-
operated, push-type, touch-type or electronically controlled
mechanisms are acceptable elements (see ADAAG 4.19.5). If Minimum Quantity 1
self-closing valves are used the faucet shall remain open for at Maximum Quantity: 1
least 10 seconds.
Unit: Each
Minimum Estimated Cost: 392
Maximum Estimated Cost: 392
Record Number 450
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 348 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The knee clearance space under the lavatory designated to be
accessible in the restroom is less than 29 inches. The knee
depth space under the lavatory designated to be accessible in
the restroom is less than 27 inches at 8 inches under the
lavatory apron.

Alternative *
Rec:
(Where
Available)

Unisex Restroom in the Stable Office

Full Rec Replace the lavatory designated to be accessible in the Citation ADAAG 4.19.2
restroom to provide at least 29 inches of clear knee space
between the finished floor and bottom of the lavatory apron.
Make sure to provide at least 27 inches at 8 inches under the Minimum Quantity 1
apron (see ADAAG 4.19.2). Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1286
Maximum Estimated Cost: 1286
Record Number 451
Priority:

Restrooms
Finding: The pipes under the lavatory in the restroom do not provide
protection against contact.

Alternative *
Rec:
(Where
Available)

Unisex Restroom in the Stable Office

Full Rec Insulate or otherwise configure pipes under the lavatory Citation ADAAG 4.19.4
designated to be accessible in the restroom to protect against
contact (see ADAAG 4.19.4). Make certain there are no sharp
or abrasive surfaces under the lavatory. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 39
Maximum Estimated Cost: 39
Record Number 452
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 349 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the controls and operating mechanisms for the
soap dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Unisex Restroom in the Stable Office

Full Rec Relocate the soap dispenser in the restroom to a maximum Citation CBC 1115B.9.2; ADAAG A4.27
height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 453
Priority:

Restrooms
Finding: The height of the controls and operating mechanisms for the
paper towel dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Unisex Restroom in the Stable Office

Full Rec Relocate the paper towel dispenser in the restroom to a Citation CBC 1115B.9.2; ADAAG A4.27
maximum height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 454
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 350 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: There is no signage indicating accessibility on the latch side of
the entry door of the restroom. The gender use signage on the
entrance door does not include the International Symbol of
Accessibility.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Building 1

Full Rec The restroom is designated accessible and should be made Citation CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7));
accessible for the facility. Post signage centered 60 inches ADAAG 4.1.6(3)(e); ADAAG 4.30
above the ground surface on the latch side of the entrance door
identifying the restroom as accessible upon completion of the Minimum Quantity 1
following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG Maximum Quantity: 1
4.1.6(3)(e). Signage shall include Braille and raised lettering,
the gender or unisex use symbol and the ISA symbol. Post Title Unit: Each
24 gender use signage on the door @ 60" o.c. a.f.f. Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 743
Priority:

Restrooms
Finding: The privacy partition at the entrance limits the minimum clear
width of the accessible route into the restroom.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Building 1

Full Rec Modify or remove the privacy partition at the entrance to the Citation CBC 1133B.2.4.2; ADAAG 4.13.6
restroom to provide a width of at least 60 inches in the direction
of the door swing and at least 48 inches in the opposite direction
of the door swing (see CBC 1133B.2.4.2, ADAAG 4.13.6 and Minimum Quantity 1
ADAAG Figure 25). Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 744
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 351 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: There is insufficient clear floor space in the stall designated to
be accessible in the restroom. The door to the stall designated
to be accessible in the restroom does not have accessible
hardware.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Building 1

Full Rec Modify or replace the stall designated to be accessible in the Citation CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
restroom so that it complies with ADAAG 4.17.3, CBC 1115B
and CBC Figures 11B-1A and 1B. Standard accessible stalls
require 60 inches in width with 56 inches depth for wall-mounted Minimum Quantity 1
toilets or 59 inches depth for floor-mounted toilets to Maximum Quantity: 1
accommodate individuals in wheelchairs. The minimum width of
a front-approach doorway shall provide at least 32 inches and a Unit: Each
side-approach doorway shall provide at least 34 inches. The Minimum Estimated Cost: 4000
door shall swing outward, close automatically and provide
accessible hardware. Maximum Estimated Cost: 4000
Record Number 745
Priority:

Restrooms
Finding: The height of the coat hook on the stall door designated to be
accessible in the restroom is greater than 48 inches above the
floor surface.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Building 1

Full Rec Remount the coat hook on the stall door designated to be Citation CBC 1115B.9.2; ADAAG A4.27
accessible in the restroom to a maximum height of 48 inches
above the floor surface.
Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 746
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 352 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: There is no back grab bar in the stall designated to be
accessible in the restroom.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Building 1

Full Rec Install a 36-inch back grab bar at a height of 33 inches above Citation CBC 1115B.8.1; ADAAG 4.26
the finished floor in the stall designated to be accessible of the
restroom. Grab bars must be able to support a point load of at
least 250 pounds and shall be less than the allowable shear Minimum Quantity 1
stress of the grab bar material. Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 531
Maximum Estimated Cost: 531
Record Number 747
Priority:

Restrooms
Finding: The height of the left grab bar in the stall designated to be
accessible of the restroom is greater than 33 inches above the
finished floor. The height of the right grab bar in the stall
designated to be accessible of the restroom is less than 33
inches above the finished floor.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Building 1

Full Rec Remount the side and back grab bar in the stall designated to Citation CBC 1115B.8.1; ADAAG 4.26
be accessible in the restroom so that the height of the gripping
surface is centered at 33 inches above finished floor. Grab bars
must be able to support a point load of at least 250 pounds and Minimum Quantity 1
shall be less than the allowable shear stress of the grab bar Maximum Quantity: 1
material.
Unit: Each
Minimum Estimated Cost: 448
Maximum Estimated Cost: 448
Record Number 748
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 353 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The right grab bar in the stall designated to be accessible in the
restroom does not extend 54 inches from the back wall.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Building 1

Full Rec The front end of the grab bar shall extend at least 54 inches Citation CBC 1115B.8.1; ADAAG 4.26
from the back wall and the back end of the grab bar shall be
mounted within 12 inches from the back wall. Grab bars must
be able to support a point load of at least 250 pounds and shall Minimum Quantity 1
be less than the allowable shear stress of the grab bar material. Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 531
Maximum Estimated Cost: 531
Record Number 749
Priority:

Restrooms
Finding: The height of the toilet seat in the stall designated to be
accessible in the restroom is less than 17 inches above the
finished floor.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Building 1

Full Rec Remove or modify the toilet in the stall designated to be Citation ADAAG 4.16.3
accessible in the restroom so that the seat height is between 17
inches and 19 inches above the finished floor (see ADAAG
4.16.3). Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1707
Maximum Estimated Cost: 1707
Record Number 751
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 354 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The seat cover dispenser in the stall designated to be
accessible in the restroom is mounted at a height greater than
40 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Building 1

Full Rec Relocate the seat cover dispenser in the stall designated to be Citation CBC 1115B.9.2
accessible in the restroom so that the height is no greater than
40 inches above the finished floor (see CBC 1115B.9.2). Make
certain that the location of the seat cover dispenser does not Minimum Quantity 1
interfere with the use of a grab bar and provides sufficient clear Maximum Quantity: 1
floor space.
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 752
Priority:

Restrooms
Finding: The faucet controls on the lavatory in the restroom require tight
grasping, pinching, or twisting of the wrist and are not
accessible.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Building 1

Full Rec Install faucet controls complying with ADAAG 4.19.5 on the Citation ADAAG 4.19.5
lavatory designated to be accessible in the restroom. Lever-
operated, push-type, touch-type or electronically controlled
mechanisms are acceptable elements (see ADAAG 4.19.5). If Minimum Quantity 1
self-closing valves are used the faucet shall remain open for at Maximum Quantity: 1
least 10 seconds.
Unit: Each
Minimum Estimated Cost: 392
Maximum Estimated Cost: 392
Record Number 753
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 355 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The knee clearance space under the lavatory designated to be
accessible in the restroom is less than 29 inches. The knee
depth space under the lavatory designated to be accessible in
the restroom is less than 27 inches at 8 inches under the
lavatory apron.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Building 1

Full Rec Replace the lavatory designated to be accessible in the Citation ADAAG 4.19.2
restroom to provide at least 29 inches of clear knee space
between the finished floor and bottom of the lavatory apron.
Make sure to provide at least 27 inches at 8 inches under the Minimum Quantity 1
apron (see ADAAG 4.19.2). Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1286
Maximum Estimated Cost: 1286
Record Number 754
Priority:

Restrooms
Finding: The pipes under the lavatory in the restroom do not provide
protection against contact.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Building 1

Full Rec Insulate or otherwise configure pipes under the lavatory Citation ADAAG 4.19.4
designated to be accessible in the restroom to protect against
contact (see ADAAG 4.19.4). Make certain there are no sharp
or abrasive surfaces under the lavatory. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 39
Maximum Estimated Cost: 39
Record Number 755
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 356 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The bottom edge of the reflecting surface of the mirror in the
restroom is greater than 40 inches above the finished floor.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Building 1

Full Rec Lower the mirror in the restroom so that the bottom edge of the Citation ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG
reflecting surface is no higher than 40 inches above the finished 4.19.6
floor and the topmost portion of the reflecting surface extends at
least 74 inches above the finished floor (see ADAAG A4.19.6). Minimum Quantity 1
A single, full-length mirror is recommended since it can Maximum Quantity: 1
accommodate all people. Make certain to provide a minimum
clear floor space in front of the mirror of 30 inches in width and Unit: Each
48 inches in length. Minimum Estimated Cost: 291
Maximum Estimated Cost: 291
Record Number 756
Priority:

Restrooms
Finding: The height of the controls and operating mechanisms for the
soap dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Building 1

Full Rec Relocate the soap dispenser in the restroom to a maximum Citation CBC 1115B.9.2; ADAAG A4.27
height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 757
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 357 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the controls and operating mechanisms for the
paper towel dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Building 1

Full Rec Relocate the paper towel dispenser in the restroom to a Citation CBC 1115B.9.2; ADAAG A4.27
maximum height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 758
Priority:

Restrooms
Finding: There is no signage indicating accessibility on the latch side of
the entry door of the restroom. The gender use signage is not
mounted on the entrance door to the restroom and is not
centered at 60 inches above the floor surface.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Building 2

Full Rec The restroom is designated accessible and should be made Citation CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7));
accessible for the facility. Post signage centered 60 inches ADAAG 4.1.6(3)(e); ADAAG 4.30
above the ground surface on the latch side of the entrance door
identifying the restroom as accessible upon completion of the Minimum Quantity 1
following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG Maximum Quantity: 1
4.1.6(3)(e). Signage shall include Braille and raised lettering,
the gender or unisex use symbol and the ISA symbol. Post Title Unit: Each
24 gender use signage on the door @ 60" o.c. a.f.f. Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 730
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 358 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: There are eight stalls located in the multiple accommodation
restroom.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Building 2

Full Rec Create an accessible 36-inch wide alternate stall in addition to Citation CBC 1115B.7.1.4; ADAAG A4.17.3; ADAAG
the required accessible standard stall in the multiple 4.22.4
accommodation restroom. The accessible 36-inch wide
alternate stall shall include an outward swinging, self-closing Minimum Quantity 1
door and parallel side grab bars and shall provide at least 66 Maximum Quantity: 1
inches in length for a stall with a wall-mounted toilet or at least
69 inches in length for a stall with a floor-mounted toilet. Unit: Each
Minimum Estimated Cost: 4000
Maximum Estimated Cost: 4000
Record Number 731
Priority:

Restrooms
Finding: There is insufficient clear floor space in the stall designated to
be accessible in the restroom. The door to the stall designated
to be accessible in the restroom does not have accessible
hardware.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Building 2

Full Rec Modify or replace the stall designated to be accessible in the Citation CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
restroom so that it complies with ADAAG 4.17.3, CBC 1115B
and CBC Figures 11B-1A and 1B. Standard accessible stalls
require 60 inches in width with 56 inches depth for wall-mounted Minimum Quantity 1
toilets or 59 inches depth for floor-mounted toilets to Maximum Quantity: 1
accommodate individuals in wheelchairs. The minimum width of
a front-approach doorway shall provide at least 32 inches and a Unit: Each
side-approach doorway shall provide at least 34 inches. The Minimum Estimated Cost: 4000
door shall swing outward, close automatically and provide
accessible hardware. Maximum Estimated Cost: 4000
Record Number 732
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 359 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the coat hook on the stall door designated to be
accessible in the restroom is greater than 48 inches above the
floor surface.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Building 2

Full Rec Remount the coat hook on the stall door designated to be Citation CBC 1115B.9.2; ADAAG A4.27
accessible in the restroom to a maximum height of 48 inches
above the floor surface.
Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 733
Priority:

Restrooms
Finding: There is no back grab bar in the stall designated to be
accessible in the restroom.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Building 2

Full Rec Install a 36-inch back grab bar at a height of 33 inches above Citation CBC 1115B.8.1; ADAAG 4.26
the finished floor in the stall designated to be accessible of the
restroom. Grab bars must be able to support a point load of at
least 250 pounds and shall be less than the allowable shear Minimum Quantity 1
stress of the grab bar material. Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 531
Maximum Estimated Cost: 531
Record Number 734
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 360 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the side grab bars in the stall designated to be
accessible of the restroom is less than 33 inches above the
finished floor.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Building 2

Full Rec Remount the side grab bars in the stall designated to be Citation CBC 1115B.8.1; ADAAG 4.26
accessible in the restroom so that the height of the gripping
surface is centered at 33 inches above finished floor. Grab bars
must be able to support a point load of at least 250 pounds and Minimum Quantity 1
shall be less than the allowable shear stress of the grab bar Maximum Quantity: 1
material.
Unit: Each
Minimum Estimated Cost: 448
Maximum Estimated Cost: 448
Record Number 735
Priority:

Restrooms
Finding: The height of the toilet seat in the stall designated to be
accessible in the restroom is less than 17 inches above the
finished floor.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Building 2

Full Rec Remove or modify the toilet in the stall designated to be Citation ADAAG 4.16.3
accessible in the restroom so that the seat height is between 17
inches and 19 inches above the finished floor (see ADAAG
4.16.3). Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1707
Maximum Estimated Cost: 1707
Record Number 736
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 361 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The distance from the center of the toilet to the nearest side
wall in the stall designated to be accessible in the restroom is
less than 18 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Building 2

Full Rec Relocate the toilet or stall side wall so that the distance from the Citation CBC 1115B.7.1.3 ADAAG 4.17.3
centerline of the toilet to the nearest side wall in the stall
designated to be accessible in the restroom is exactly 18 inches
(see ADAAG Figure 28. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1143
Maximum Estimated Cost: 1143
Record Number 737
Priority:

Restrooms
Finding: The knee clearance space under the lavatory designated to be
accessible in the restroom is less than 29 inches. The knee
depth space under the lavatory designated to be accessible in
the restroom is less than 27 inches at 8 inches under the
lavatory apron.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Building 2

Full Rec Replace the lavatory designated to be accessible in the Citation ADAAG 4.19.2
restroom to provide at least 29 inches of clear knee space
between the finished floor and bottom of the lavatory apron.
Make sure to provide at least 27 inches at 8 inches under the Minimum Quantity 1
apron (see ADAAG 4.19.2). Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1286
Maximum Estimated Cost: 1286
Record Number 738
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 362 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The pipes under the lavatory in the restroom do not provide
protection against contact.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Building 2

Full Rec Insulate or otherwise configure pipes under the lavatory Citation ADAAG 4.19.4
designated to be accessible in the restroom to protect against
contact (see ADAAG 4.19.4). Make certain there are no sharp
or abrasive surfaces under the lavatory. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 39
Maximum Estimated Cost: 39
Record Number 739
Priority:

Restrooms
Finding: The bottom edge of the reflecting surface of the mirror in the
restroom is greater than 40 inches above the finished floor.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Building 2

Full Rec Lower the mirror in the restroom so that the bottom edge of the Citation ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG
reflecting surface is no higher than 40 inches above the finished 4.19.6
floor and the topmost portion of the reflecting surface extends at
least 74 inches above the finished floor (see ADAAG A4.19.6). Minimum Quantity 1
A single, full-length mirror is recommended since it can Maximum Quantity: 1
accommodate all people. Make certain to provide a minimum
clear floor space in front of the mirror of 30 inches in width and Unit: Each
48 inches in length. Minimum Estimated Cost: 291
Maximum Estimated Cost: 291
Record Number 740
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 363 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the controls and operating mechanisms for the
soap dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Building 2

Full Rec Relocate the soap dispenser in the restroom to a maximum Citation CBC 1115B.9.2; ADAAG A4.27
height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 741
Priority:

Restrooms
Finding: The height of the controls and operating mechanisms for the
paper towel dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Building 2

Full Rec Relocate the paper towel dispenser in the restroom to a Citation CBC 1115B.9.2; ADAAG A4.27
maximum height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 742
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 364 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: There is no signage indicating accessibility on the latch side of
the entry door of the restroom. The gender use signage is not
mounted on the entrance door and does not include the
International Symbol of Accessibility.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Building 4

Full Rec The restroom is designated accessible and should be made Citation CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7));
accessible for the facility. Post signage centered 60 inches ADAAG 4.1.6(3)(e); ADAAG 4.30
above the ground surface on the latch side of the entrance door
identifying the restroom as accessible upon completion of the Minimum Quantity 1
following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG Maximum Quantity: 1
4.1.6(3)(e). Signage shall include Braille and raised lettering,
the gender or unisex use symbol and the ISA symbol. Post Title Unit: Each
24 gender use signage on the door @ 60" o.c. a.f.f. Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 977
Priority:

Restrooms
Finding: The clear opening width of the entrance doorway to the
restroom is less than 32 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Building 4

Full Rec Widen the entrance doorway to the restroom to provide a clear Citation ADAAG 4.13.5
opening width of at least 32 inches when the door is open 90
degrees (see ADAAG 4.13.5).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 750
Maximum Estimated Cost: 750
Record Number 978
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 365 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The bottom 10 inches of the door does not provide a smooth,
uninterrupted surface, or panel to allow the door to be opened
by a wheelchair footrest without creating a trap or hazardous
condition, due to the doorstop.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Building 4

Full Rec Install a panel or replace the door to provide a smooth, Citation CBC 1133B.2.6
uninterrupted surface for the bottom 10 inches of the door.

Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 979
Priority:

Restrooms
Finding: The privacy partition at the entrance limits the minimum clear
width of the accessible route into the restroom.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Building 4

Full Rec Modify or remove the privacy partition at the entrance to the Citation CBC 1133B.2.4.2; ADAAG 4.13.6
restroom to provide a width of at least 60 inches in the direction
of the door swing and at least 48 inches in the opposite direction
of the door swing (see CBC 1133B.2.4.2, ADAAG 4.13.6 and Minimum Quantity 1
ADAAG Figure 25). Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 980
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 366 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: There is insufficient clear floor space in the stall designated to
be accessible in the restroom. The door to the stall designated
to be accessible in the restroom does not have accessible
hardware.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Building 4

Full Rec Modify or replace the stall designated to be accessible in the Citation CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
restroom so that it complies with ADAAG 4.17.3, CBC 1115B
and CBC Figures 11B-1A and 1B. Standard accessible stalls
require 60 inches in width with 56 inches depth for wall-mounted Minimum Quantity 1
toilets or 59 inches depth for floor-mounted toilets to Maximum Quantity: 1
accommodate individuals in wheelchairs. The minimum width of
a front-approach doorway shall provide at least 32 inches and a Unit: Each
side-approach doorway shall provide at least 34 inches. The Minimum Estimated Cost: 4000
door shall swing outward, close automatically and provide
accessible hardware. Maximum Estimated Cost: 4000
Record Number 981
Priority:

Restrooms
Finding: The height of the coat hook on the stall door designated to be
accessible in the restroom is greater than 48 inches above the
floor surface.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Building 4

Full Rec Remount the coat hook on the stall door designated to be Citation CBC 1115B.9.2; ADAAG A4.27
accessible in the restroom to a maximum height of 48 inches
above the floor surface.
Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 982
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 367 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: There is no back grab bar in the stall designated to be
accessible in the restroom.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Building 4

Full Rec Install a 36-inch back grab bar at a height of 33 inches above Citation CBC 1115B.8.1; ADAAG 4.26
the finished floor in the stall designated to be accessible of the
restroom. Grab bars must be able to support a point load of at
least 250 pounds and shall be less than the allowable shear Minimum Quantity 1
stress of the grab bar material. Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 531
Maximum Estimated Cost: 531
Record Number 983
Priority:

Restrooms
Finding: The height of the left grab bar in the stall designated to be
accessible of the restroom is less than 33 inches above the
finished floor. The height of the right grab bar in the stall
designated to be accessible of the restroom is greater than 33
inches above the finished floor.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Building 4

Full Rec Remount the side grab bars in the stall designated to be Citation CBC 1115B.8.1; ADAAG 4.26
accessible in the restroom so that the height of the gripping
surface is centered at 33 inches above finished floor. Grab bars
must be able to support a point load of at least 250 pounds and Minimum Quantity 1
shall be less than the allowable shear stress of the grab bar Maximum Quantity: 1
material.
Unit: Each
Minimum Estimated Cost: 448
Maximum Estimated Cost: 448
Record Number 984
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 368 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The side grab bars in the stall designated to be accessible in
the restroom do not extend 54 inches from the back wall.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Building 4

Full Rec The front end of the grab bars shall extend at least 54 inches Citation CBC 1115B.8.1; ADAAG 4.26
from the back wall and the back end of the grab bar shall be
mounted within 12 inches from the back wall. Grab bars must
be able to support a point load of at least 250 pounds and shall Minimum Quantity 1
be less than the allowable shear stress of the grab bar material. Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 531
Maximum Estimated Cost: 531
Record Number 985
Priority:

Restrooms
Finding: The toilet paper dispenser protrudes more than 4 inches from
the side wall and interferes with the clear floor space of the
water closet.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Building 4

Full Rec Remount or replace the toilet paper dispenser so that it does not Citation DSA Access Policy 99-07
encroach more than four inches from the face of the wall. Make
sure it does not interfere with the use of the side grab bar (see
ADAAG 4.16.6 and Figure 29(b)). Toilet paper dispensers must Minimum Quantity 1
allow continuous paper flow and be mounted within 12" in front Maximum Quantity: 1
of the water closet.
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 986
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 369 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The flush control on the toilet in the stall designated to be
accessible in the restroom is not on the wide (approach) side of
the toilet. The flush controls are nonaccessible and requires the
use of foot controls to operate.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Building 4

Full Rec Relocate the flush control on the toilet in the stall designated to Citation ADAAG 4.16.5; ADAAG 4.27.4
be accessible in the restroom so that it is on the wide
(approach) side of the toilet area (see ADAAG 4.16.5). Flush
controls shall be hand-operated or automatic mechanisms. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 127
Maximum Estimated Cost: 127
Record Number 987
Priority:

Restrooms
Finding: The height of the toilet seat in the stall designated to be
accessible in the restroom is less than 17 inches above the
finished floor.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Building 4

Full Rec Remove or modify the toilet in the stall designated to be Citation ADAAG 4.16.3
accessible in the restroom so that the seat height is between 17
inches and 19 inches above the finished floor (see ADAAG
4.16.3). Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1707
Maximum Estimated Cost: 1707
Record Number 988
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 370 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The distance from the center of the toilet to the nearest side
wall in the stall designated to be accessible in the restroom is
greater than 18 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Building 4

Full Rec Relocate the toilet or stall side wall so that the distance from the Citation CBC 1115B.7.1.3 ADAAG 4.17.3
centerline of the toilet to the nearest side wall in the stall
designated to be accessible in the restroom is exactly 18 inches
(see ADAAG Figure 28. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1143
Maximum Estimated Cost: 1143
Record Number 989
Priority:

Restrooms
Finding: The seat cover dispenser in the stall designated to be
accessible in the restroom is mounted at a height greater than
40 inches and there is no clear floor space.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Building 4

Full Rec Relocate the seat cover dispenser in the stall designated to be Citation CBC 1115B.9.2
accessible in the restroom so that the height is no greater than
40 inches above the finished floor (see CBC 1115B.9.2). Make
certain that the location of the seat cover dispenser does not Minimum Quantity 1
interfere with the use of a grab bar and provides sufficient clear Maximum Quantity: 1
floor space.
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 990
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 371 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The faucet controls on the lavatory in the restroom require tight
grasping, pinching, or twisting of the wrist and are not
accessible.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Building 4

Full Rec Install faucet controls complying with ADAAG 4.19.5 on the Citation ADAAG 4.19.5
lavatory designated to be accessible in the restroom. Lever-
operated, push-type, touch-type or electronically controlled
mechanisms are acceptable elements (see ADAAG 4.19.5). If Minimum Quantity 1
self-closing valves are used the faucet shall remain open for at Maximum Quantity: 1
least 10 seconds.
Unit: Each
Minimum Estimated Cost: 392
Maximum Estimated Cost: 392
Record Number 991
Priority:

Restrooms
Finding: The knee clearance space under the lavatory designated to be
accessible in the restroom is less than 29 inches. The knee
depth space under the lavatory designated to be accessible in
the restroom is less than 27 inches at 8 inches under the
lavatory apron.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Building 4

Full Rec Replace the lavatory designated to be accessible in the Citation ADAAG 4.19.2
restroom to provide at least 29 inches of clear knee space
between the finished floor and bottom of the lavatory apron.
Make sure to provide at least 27 inches at 8 inches under the Minimum Quantity 1
apron (see ADAAG 4.19.2). Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1286
Maximum Estimated Cost: 1286
Record Number 992
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 372 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The pipes under the lavatory in the restroom do not provide
protection against contact.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Building 4

Full Rec Insulate or otherwise configure pipes under the lavatory Citation ADAAG 4.19.4
designated to be accessible in the restroom to protect against
contact (see ADAAG 4.19.4). Make certain there are no sharp
or abrasive surfaces under the lavatory. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 39
Maximum Estimated Cost: 39
Record Number 993
Priority:

Restrooms
Finding: The bottom edge of the reflecting surface of the mirror in the
restroom is greater than 40 inches above the finished floor.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Building 4

Full Rec Lower the mirror in the restroom so that the bottom edge of the Citation ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG
reflecting surface is no higher than 40 inches above the finished 4.19.6
floor and the topmost portion of the reflecting surface extends at
least 74 inches above the finished floor (see ADAAG A4.19.6). Minimum Quantity 1
A single, full-length mirror is recommended since it can Maximum Quantity: 1
accommodate all people. Make certain to provide a minimum
clear floor space in front of the mirror of 30 inches in width and Unit: Each
48 inches in length. Minimum Estimated Cost: 291
Maximum Estimated Cost: 291
Record Number 994
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 373 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the controls and operating mechanisms for the
soap dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Building 4

Full Rec Relocate the soap dispenser in the restroom to a maximum Citation CBC 1115B.9.2; ADAAG A4.27
height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 995
Priority:

Restrooms
Finding: There is no signage indicating accessibility on the latch side of
the entry door of the restroom. There is no Title 24 gender use
signage on the entrance door.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Building 5

Full Rec The restroom is designated accessible and should be made Citation CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7));
accessible for the facility. Post signage centered 60 inches ADAAG 4.1.6(3)(e); ADAAG 4.30
above the ground surface on the latch side of the entrance door
identifying the restroom as accessible upon completion of the Minimum Quantity 1
following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG Maximum Quantity: 1
4.1.6(3)(e). Signage shall include Braille and raised lettering,
the gender or unisex use symbol and the ISA symbol. Post Title Unit: Each
24 gender use signage on the door @ 60" o.c. a.f.f. Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 540
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 374 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The clear opening width of the entrance doorway to the
restroom is less than 32 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Building 5

Full Rec Widen the entrance doorway to the restroom to provide a clear Citation ADAAG 4.13.5
opening width of at least 32 inches when the door is open 90
degrees (see ADAAG 4.13.5).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 750
Maximum Estimated Cost: 750
Record Number 541
Priority:

Restrooms
Finding: The entrance door to the restroom has a round doorknob that
requires tight grasping or twisting of the wrist to operate.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Building 5

Full Rec Replace the door hardware mounted on the restroom complying Citation ADAAG 4.13.9
with ADAAG 4.13.9. Make certain accessible door hardware is
mounted no higher than 48 inches above the finished floor.
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 204
Maximum Estimated Cost: 204
Record Number 542
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 375 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The bottom 10 inches of the door does not provide a smooth,
uninterrupted surface, or panel to allow the door to be opened
by a wheelchair footrest without creating a trap or hazardous
condition, due to the door stop.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Building 5

Full Rec Install a panel or replace the door to provide a smooth, Citation CBC 1133B.2.6
uninterrupted surface for the bottom 10 inches of the door.

Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 543
Priority:

Restrooms
Finding: There is insufficient clear floor space in the stall designated to
be accessible in the restroom. The door to the stall designated
to be accessible in the restroom does not close automatically.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Building 5

Full Rec Modify or replace the stall designated to be accessible in the Citation CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
restroom so that it complies with ADAAG 4.17.3, CBC 1115B
and CBC Figures 11B-1A and 1B. Standard accessible stalls
require 60 inches in width with 56 inches depth for wall-mounted Minimum Quantity 1
toilets or 59 inches depth for floor-mounted toilets to Maximum Quantity: 1
accommodate individuals in wheelchairs. The minimum width of
a front-approach doorway shall provide at least 32 inches and a Unit: Each
side-approach doorway shall provide at least 34 inches. The Minimum Estimated Cost: 4000
door shall swing outward, close automatically and provide
accessible hardware. Maximum Estimated Cost: 4000
Record Number 544
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 376 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the side grab bar in the stall designated to be
accessible of the restroom is greater than 33 inches above the
finished floor.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Building 5

Full Rec Remount the side grab bar in the stall designated to be Citation CBC 1115B.8.1; ADAAG 4.26
accessible in the restroom so that the height of the gripping
surface is centered at 33 inches above finished floor. Grab bars
must be able to support a point load of at least 250 pounds and Minimum Quantity 1
shall be less than the allowable shear stress of the grab bar Maximum Quantity: 1
material.
Unit: Each
Minimum Estimated Cost: 448
Maximum Estimated Cost: 448
Record Number 545
Priority:

Restrooms
Finding: The side grab bar in the stall designated to be accessible in the
restroom does not extend 54 inches from the back wall.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Building 5

Full Rec The front end of the grab bar shall extend at least 54 inches Citation CBC 1115B.8.1; ADAAG 4.26
from the back wall and the back end of the grab bar shall be
mounted within 12 inches from the back wall. Grab bars must
be able to support a point load of at least 250 pounds and shall Minimum Quantity 1
be less than the allowable shear stress of the grab bar material. Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 531
Maximum Estimated Cost: 531
Record Number 546
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 377 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The pipes under the lavatory in the restroom do not provide
protection against contact.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Building 5

Full Rec Insulate or otherwise configure pipes under the lavatory Citation ADAAG 4.19.4
designated to be accessible in the restroom to protect against
contact (see ADAAG 4.19.4). Make certain there are no sharp
or abrasive surfaces under the lavatory. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 39
Maximum Estimated Cost: 39
Record Number 547
Priority:

Restrooms
Finding: The height of the controls and operating mechanisms for the
soap dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Building 5

Full Rec Relocate the soap dispenser in the restroom to a maximum Citation CBC 1115B.9.2; ADAAG A4.27
height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 548
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 378 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the controls and operating mechanisms for the
paper towel dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Building 5

Full Rec Relocate the paper towel dispenser in the restroom to a Citation CBC 1115B.9.2; ADAAG A4.27
maximum height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 549
Priority:

Restrooms
Finding: There is no signage indicating accessibility on the latch side of
the entry door of the restroom. The gender use signage on the
entrance door does not include Braille or the ISA symbol.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Flat's BBQ

Full Rec The restroom is designated accessible and should be made Citation CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7));
accessible for the facility. Post signage centered 60 inches ADAAG 4.1.6(3)(e); ADAAG 4.30
above the ground surface on the latch side of the entrance door
identifying the restroom as accessible upon completion of the Minimum Quantity 1
following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG Maximum Quantity: 1
4.1.6(3)(e). Signage shall include Braille and raised lettering,
the gender or unisex use symbol and the ISA symbol. Post Title Unit: Each
24 gender use signage on the door @ 60" o.c. a.f.f. Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 1073
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 379 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: There is insufficient clear floor space in the stall designated to
be accessible in the restroom. The stall door to the stall
designated to be accessible in the restroom swings inward
limiting the clear floor space in the stall designated to be
accessible. The door to the stall designated to be accessible in
the restroom does not close automatically.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Flat's BBQ

Full Rec Modify or replace the stall designated to be accessible in the Citation CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
restroom so that it complies with ADAAG 4.17.3, CBC 1115B
and CBC Figures 11B-1A and 1B. Standard accessible stalls
require 60 inches in width with 56 inches depth for wall-mounted Minimum Quantity 1
toilets or 59 inches depth for floor-mounted toilets to Maximum Quantity: 1
accommodate individuals in wheelchairs. The minimum width of
a front-approach doorway shall provide at least 32 inches and a Unit: Each
side-approach doorway shall provide at least 34 inches. The Minimum Estimated Cost: 4000
door shall swing outward, close automatically and provide
accessible hardware. Maximum Estimated Cost: 4000
Record Number 1074
Priority:

Restrooms
Finding: The distance from the end of the back grab bar to the nearest
side wall in the stall designated to be accessible of the restroom
is greater than 6 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Flat's BBQ

Full Rec Remount the back grab bar in the stall designated to be Citation ADAAG 4.26; CBC 1115B.8.1
accessible in the restroom so that it is not more than 6 inches
from the nearest side wall (see ADAAG 4.26 and CBC Figure
11B.1A-1C). Grab bars must be able to support a point load of Minimum Quantity 1
at least 250 pounds and shall be less than the allowable shear Maximum Quantity: 1
stress of the grab bar material.
Unit: Each
Minimum Estimated Cost: 448
Maximum Estimated Cost: 448
Record Number 1075
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 380 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The side grab bar in the stall designated to be accessible in the
restroom does not extend 54 inches from the back wall.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Flat's BBQ

Full Rec The front end of the grab bar shall extend at least 54 inches Citation CBC 1115B.8.1; ADAAG 4.26
from the back wall and the back end of the grab bar shall be
mounted within 12 inches from the back wall. Grab bars must
be able to support a point load of at least 250 pounds and shall Minimum Quantity 1
be less than the allowable shear stress of the grab bar material. Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 531
Maximum Estimated Cost: 531
Record Number 1076
Priority:

Restrooms
Finding: The flush control on the toilet in the stall designated to be
accessible in the restroom is not on the wide (approach) side of
the toilet.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Flat's BBQ

Full Rec Relocate the flush control on the toilet in the stall designated to Citation ADAAG 4.16.5; ADAAG 4.27.4
be accessible in the restroom so that it is on the wide
(approach) side of the toilet area (see ADAAG 4.16.5). Flush
controls shall be hand-operated or automatic mechanisms. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 127
Maximum Estimated Cost: 127
Record Number 1078
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 381 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the toilet seat in the stall designated to be
accessible in the restroom is greater than 19 inches above the
finished floor.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Flat's BBQ

Full Rec Remove or modify the toilet in the stall designated to be Citation ADAAG 4.16.3
accessible in the restroom so that the seat height is between 17
inches and 19 inches above the finished floor (see ADAAG
4.16.3). Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1707
Maximum Estimated Cost: 1707
Record Number 1079
Priority:

Restrooms
Finding: The distance from the center of the toilet to the nearest side
wall in the stall designated to be accessible in the restroom is
greater than 18 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Flat's BBQ

Full Rec Relocate the toilet or stall side wall so that the distance from the Citation CBC 1115B.7.1.3 ADAAG 4.17.3
centerline of the toilet to the nearest side wall in the stall
designated to be accessible in the restroom is exactly 18 inches
(see ADAAG Figure 28. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1143
Maximum Estimated Cost: 1143
Record Number 1080
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 382 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The seat cover dispenser in the stall designated to be
accessible in the restroom is mounted at a height greater than
40 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Flat's BBQ

Full Rec Relocate the seat cover dispenser in the stall designated to be Citation CBC 1115B.9.2
accessible in the restroom so that the height is no greater than
40 inches above the finished floor (see CBC 1115B.9.2). Make
certain that the location of the seat cover dispenser does not Minimum Quantity 1
interfere with the use of a grab bar and provides sufficient clear Maximum Quantity: 1
floor space.
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 1081
Priority:

Restrooms
Finding: The knee clearance space under the lavatory designated to be
accessible in the restroom is less than 29 inches. The knee
depth space under the lavatory designated to be accessible in
the restroom is less than 27 inches at 8 inches under the
lavatory apron.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Flat's BBQ

Full Rec Replace the lavatory designated to be accessible in the Citation ADAAG 4.19.2
restroom to provide at least 29 inches of clear knee space
between the finished floor and bottom of the lavatory apron.
Make sure to provide at least 27 inches at 8 inches under the Minimum Quantity 1
apron (see ADAAG 4.19.2). Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1286
Maximum Estimated Cost: 1286
Record Number 1082
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 383 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The controls and operating mechanisms on the paper towel
dispenser in the restroom require tight grasping, pinching, or
twisting of the wrist and the use of two hands to operate. The
height of the operating controls on the dispenser is at a height
greater than 40 inches above the finished floor.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Flat's BBQ

Full Rec Modify or replace the paper towel dispenser in the restroom so Citation ADAAG 4.27.4, CBC 1117B.6.4
that its controls and operating mechanisms can be operated
with one hand and comply with ADAAG 4.27.4 and CBC
1117B.6.4. Make certain that the force to activate the operating Minimum Quantity 1
controls shall be no greater than 5 pounds and that the height Maximum Quantity: 1
shall be no greater than 40 inches above the finished floor.
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 1083
Priority:

Restrooms
Finding: There is no signage indicating accessibility on the latch side of
the entry door of the restroom.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Horse Barn 1

Full Rec The restroom is designated accessible and should be made Citation CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7));
accessible for the facility. Post signage centered 60 inches ADAAG 4.1.6(3)(e); ADAAG 4.30
above the ground surface on the latch side of the entrance door
identifying the restroom as accessible upon completion of the Minimum Quantity 1
following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG Maximum Quantity: 1
4.1.6(3)(e). Signage shall include Braille and raised lettering,
the gender or unisex use symbol and the ISA symbol. Unit: Each
Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 572
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 384 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: There is insufficient clear floor space in the stall designated to
be accessible in the restroom. The stall door to the stall
designated to be accessible in the restroom swings inward
limiting the clear floor space in the stall designated to be
accessible. The door to the stall designated to be accessible in
the restroom does not close automatically or have accessible
hardware.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Horse Barn 1

Full Rec Modify or replace the stall designated to be accessible in the Citation CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
restroom so that it complies with ADAAG 4.17.3, CBC 1115B
and CBC Figures 11B-1A and 1B. Standard accessible stalls
require 60 inches in width with 56 inches depth for wall-mounted Minimum Quantity 1
toilets or 59 inches depth for floor-mounted toilets to Maximum Quantity: 1
accommodate individuals in wheelchairs. The minimum width of
a front-approach doorway shall provide at least 32 inches and a Unit: Each
side-approach doorway shall provide at least 34 inches. The Minimum Estimated Cost: 4000
door shall swing outward, close automatically and provide
accessible hardware. Maximum Estimated Cost: 4000
Record Number 573
Priority:

Restrooms
Finding: There are no grab bars in the stall designated to be accessible
in the restroom.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Horse Barn 1

Full Rec Install one 36-inch back grab bar and one 42/48-inch side grab Citation CBC 1115B.8; ADAAG 4.26
bar in the stall designated to be accessible in the restroom.
Grab bars shall be mounted at a height of 33 inches above the
finished floor. Grab bars must be able to support a point load of Minimum Quantity 1
at least 250 pounds and shall be less than the allowable shear Maximum Quantity: 1
stress of the grab bar material.
Unit: Each
Minimum Estimated Cost: 531
Maximum Estimated Cost: 531
Record Number 574
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 385 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the toilet seat in the stall designated to be
accessible in the restroom is less than 17 inches above the
finished floor.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Horse Barn 1

Full Rec Remove or modify the toilet in the stall designated to be Citation ADAAG 4.16.3
accessible in the restroom so that the seat height is between 17
inches and 19 inches above the finished floor (see ADAAG
4.16.3). Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1707
Maximum Estimated Cost: 1707
Record Number 575
Priority:

Restrooms
Finding: The distance from the center of the toilet to the nearest side
wall in the stall designated to be accessible in the restroom is
less than 18 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Horse Barn 1

Full Rec Relocate the toilet or stall side wall so that the distance from the Citation CBC 1115B.7.1.3 ADAAG 4.17.3
centerline of the toilet to the nearest side wall in the stall
designated to be accessible in the restroom is exactly 18 inches
(see ADAAG Figure 28. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1143
Maximum Estimated Cost: 1143
Record Number 576
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 386 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The seat cover dispenser in the stall designated to be
accessible in the restroom is mounted at a height greater than
40 inches and there is no clear floor space.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Horse Barn 1

Full Rec Relocate the seat cover dispenser in the stall designated to be Citation CBC 1115B.9.2
accessible in the restroom so that the height is no greater than
40 inches above the finished floor (see CBC 1115B.9.2). Make
certain that the location of the seat cover dispenser does not Minimum Quantity 1
interfere with the use of a grab bar and provides sufficient clear Maximum Quantity: 1
floor space.
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 577
Priority:

Restrooms
Finding: The pipes under the lavatory in the restroom do not provide
protection against contact.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Horse Barn 1

Full Rec Insulate or otherwise configure pipes under the lavatory Citation ADAAG 4.19.4
designated to be accessible in the restroom to protect against
contact (see ADAAG 4.19.4). Make certain there are no sharp
or abrasive surfaces under the lavatory. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 39
Maximum Estimated Cost: 39
Record Number 578
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 387 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The bottom edge of the reflecting surface of the mirror in the
restroom is greater than 40 inches above the finished floor.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Horse Barn 1

Full Rec Lower the mirror in the restroom so that the bottom edge of the Citation ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG
reflecting surface is no higher than 40 inches above the finished 4.19.6
floor and the topmost portion of the reflecting surface extends at
least 74 inches above the finished floor (see ADAAG A4.19.6). Minimum Quantity 1
A single, full-length mirror is recommended since it can Maximum Quantity: 1
accommodate all people. Make certain to provide a minimum
clear floor space in front of the mirror of 30 inches in width and Unit: Each
48 inches in length. Minimum Estimated Cost: 291
Maximum Estimated Cost: 291
Record Number 579
Priority:

Restrooms
Finding: The height of the controls and operating mechanisms for the
soap dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Horse Barn 1

Full Rec Relocate the soap dispenser in the restroom to a maximum Citation CBC 1115B.9.2; ADAAG A4.27
height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 580
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 388 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the controls and operating mechanisms for the
paper towel dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Horse Barn 1

Full Rec Relocate the paper towel dispenser in the restroom to a Citation CBC 1115B.9.2; ADAAG A4.27
maximum height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 581
Priority:

Restrooms
Finding: There are no accessible shower stalls provided in the restroom.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Horse Barn 1

Full Rec Since shower stalls are provided in the restroom, at least one Citation CBC 1115B.6.2; ADAAG 4.21
accessible shower stall is required. Install an accessible shower
stall complying with CBC 1115B 6.2 and ADAAG 4.21 in the
restroom. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 2853
Maximum Estimated Cost: 2853
Record Number 582
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 389 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The signage indicating accessibility at the entry to the restroom
is not mounted on the latch side of the entrance door and is not
centered at 60 inches above the floor surface. The gender use
signage is not mounted on the entrance door and is not
centered at 60 inches above the floor surface.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Horse Barn 3

Full Rec The restroom is designated accessible and should be made Citation CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7));
accessible for the facility. Post signage centered 60 inches ADAAG 4.1.6(3)(e); ADAAG 4.30
above the ground surface on the latch side of the entrance door
identifying the restroom as accessible upon completion of the Minimum Quantity 1
following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG Maximum Quantity: 1
4.1.6(3)(e). Signage shall include Braille and raised lettering,
the gender or unisex use symbol and the ISA symbol. Post Title Unit: Each
24 gender use signage on the door @ 60" o.c. a.f.f. Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 550
Priority:

Restrooms
Finding: The door to the stall designated to be accessible in the
restroom does not have accessible hardware.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Horse Barn 3

Full Rec Provide an automatic door closer, spring hinge, pull bar or Citation ADAAG A4.17.5
accessible handle mounted on the inside of the stall door to the
stall designated to be accessible in the restroom (see ADAAG
A4.17.5). Accessible hardware on the inside and outside of the Minimum Quantity 1
stall designated to be accessible door shall be equipped with a Maximum Quantity: 1
loop or U-shaped handle mounted immediately below the latch.
The latch shall be flip-over style, sliding or other hardware not Unit: Each
requiring grasping or twisting. Make certain that the inside and Minimum Estimated Cost: 269
outside door hardware is mounted no more than 48 inches
above the finished floor (see CBC 115B.7.1.3 and ADAAG Maximum Estimated Cost: 269
4.13.9). Record Number 551
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 390 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the coat hook on the stall door designated to be
accessible in the restroom is greater than 48 inches above the
floor surface.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Horse Barn 3

Full Rec Remount the coat hook on the stall door designated to be Citation CBC 1115B.9.2; ADAAG A4.27
accessible in the restroom to a maximum height of 48 inches
above the floor surface.
Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 552
Priority:

Restrooms
Finding: There is less than 48 inches of clear floor space provided in
front of the toilet in the restroom to allow an accessible forward
approach.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Horse Barn 3

Full Rec The minimum clear floor space in front of the toilet designated to Citation CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
be accessible in the restroom shall be at least 48 inches to
provide an accessible forward approach (see CBC 1115B.9.4
and ADAAG 4.18.3). Consult a design professional to Minimum Quantity 1
determine if elements or walls need to be removed to provide Maximum Quantity: 1
sufficient clear floor space in front of the toilet.
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 553
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 391 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the side grab bar in the stall designated to be
accessible of the restroom is greater than 33 inches above the
finished floor.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Horse Barn 3

Full Rec Remount the side grab bar in the stall designated to be Citation CBC 1115B.8.1; ADAAG 4.26
accessible in the restroom so that the height of the gripping
surface is centered at 33 inches above finished floor. Grab bars
must be able to support a point load of at least 250 pounds and Minimum Quantity 1
shall be less than the allowable shear stress of the grab bar Maximum Quantity: 1
material.
Unit: Each
Minimum Estimated Cost: 448
Maximum Estimated Cost: 448
Record Number 554
Priority:

Restrooms
Finding: The distance from the center of the toilet to the nearest side
wall in the stall designated to be accessible in the restroom is
greater than 18 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Horse Barn 3

Full Rec Relocate the toilet or stall side wall so that the distance from the Citation CBC 1115B.7.1.3 ADAAG 4.17.3
centerline of the toilet to the nearest side wall in the stall
designated to be accessible in the restroom is exactly 18 inches
(see ADAAG Figure 28. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1143
Maximum Estimated Cost: 1143
Record Number 555
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 392 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The knee clearance space under the lavatory designated to be
accessible in the restroom is less than 29 inches. The knee
depth space under the lavatory designated to be accessible in
the restroom is less than 27 inches at 8 inches under the
lavatory apron.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Horse Barn 3

Full Rec Raise or replace the lavatory designated to be accessible in the Citation ADAAG 4.19.2
restroom to provide at least 29 inches of clear knee space
between the finished floor and bottom of the lavatory apron.
Make sure to provide at least 27 inches at 8 inches under the Minimum Quantity 1
apron (see ADAAG 4.19.2). Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1286
Maximum Estimated Cost: 1286
Record Number 556
Priority:

Restrooms
Finding: The pipes under the lavatory in the restroom do not provide
protection against contact.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Horse Barn 3

Full Rec Insulate or otherwise configure pipes under the lavatory Citation ADAAG 4.19.4
designated to be accessible in the restroom to protect against
contact (see ADAAG 4.19.4). Make certain there are no sharp
or abrasive surfaces under the lavatory. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 39
Maximum Estimated Cost: 39
Record Number 557
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 393 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the controls and operating mechanisms for the
paper towel dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Horse Barn 3

Full Rec Relocate the paper towel dispenser in the restroom to a Citation CBC 1115B.9.2; ADAAG A4.27
maximum height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 558
Priority:

Restrooms
Finding: The hand-held sprayer unit is mounted at a height greater than
48 inches above the finished floor. The length of the hose for
the hand-held sprayer unit is less than 60 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Horse Barn 3

Full Rec Install a hand-held sprayer unit in the shower compartment Citation ADAAG 4.21.6; CBC 1115B.6.2.4.2
designated to be accessible in the restroom with a hose at leapt
60 inches in length. The centerline of the hand-held sprayer unit
shall be mounted within 27 inches from the rear seat edge and Minimum Quantity 1
at a height no greater than 48 inches from the finished floor (see Maximum Quantity: 1
CBC 1115B.6.2.4.2).
Unit: Each
Minimum Estimated Cost: 385
Maximum Estimated Cost: 385
Record Number 1201
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 394 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: There is no signage indicating accessibility on the latch side of
the entry door of the restroom.

Alternative *
Rec:
(Where
Available)

Women's Restroom at L-1

Full Rec The restroom is designated accessible and should be made Citation CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7));
accessible for the facility. Post signage centered 60 inches ADAAG 4.1.6(3)(e); ADAAG 4.30
above the ground surface on the latch side of the entrance door
identifying the restroom as accessible upon completion of the Minimum Quantity 1
following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG Maximum Quantity: 1
4.1.6(3)(e). Signage shall include Braille and raised lettering,
the gender or unisex use symbol and the ISA symbol. Post Title Unit: Each
24 gender use signage on the door @ 60" o.c. a.f.f. Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 829
Priority:

Restrooms
Finding: There is less than 12 inches of latch side clearance from the
push side of the entrance door.

Alternative *
Rec:
(Where
Available)

Women's Restroom at L-1

Full Rec Consult a design professional to determine if it is technically Citation ADAAG 4.13.6
feasible to provide at least 12 inches of latch side clearance at
the entrance door from the push side (see ADAAG 4.13.6 and
Figure 25). Otherwise, install an automatic door opening device Minimum Quantity 1
to the primary entrance complying with ADAAG 4.13.12 and Maximum Quantity: 1
ANSI/BHMA A156.10, 1985, standards.
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 830
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 395 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: There is insufficient clear floor space in the stall designated to
be accessible in the restroom. The inside handle on the stall
door is not mounted immediately below the latch.

Alternative *
Rec:
(Where
Available)

Women's Restroom at L-1

Full Rec Modify or replace the stall designated to be accessible in the Citation CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
restroom so that it complies with ADAAG 4.17.3, CBC 1115B
and CBC Figures 11B-1A and 1B. Standard accessible stalls
require 60 inches in width with 56 inches depth for wall-mounted Minimum Quantity 1
toilets or 59 inches depth for floor-mounted toilets to Maximum Quantity: 1
accommodate individuals in wheelchairs. The minimum width of
a front-approach doorway shall provide at least 32 inches and a Unit: Each
side-approach doorway shall provide at least 34 inches. The Minimum Estimated Cost: 4000
door shall swing outward, close automatically and provide
accessible hardware. Maximum Estimated Cost: 4000
Record Number 831
Priority:

Restrooms
Finding: There is no back grab bar in the stall designated to be
accessible in the restroom.

Alternative *
Rec:
(Where
Available)

Women's Restroom at L-1

Full Rec Install a 36-inch back grab bar at a height of 33 inches above Citation CBC 1115B.8.1; ADAAG 4.26
the finished floor in the stall designated to be accessible of the
restroom. Grab bars must be able to support a point load of at
least 250 pounds and shall be less than the allowable shear Minimum Quantity 1
stress of the grab bar material. Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 531
Maximum Estimated Cost: 531
Record Number 832
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 396 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the side grab bars in the stall designated to be
accessible of the restroom is greater than 33 inches above the
finished floor.

Alternative *
Rec:
(Where
Available)

Women's Restroom at L-1

Full Rec Remount the side grab bars in the stall designated to be Citation CBC 1115B.8.1; ADAAG 4.26
accessible in the restroom so that the height of the gripping
surface is centered at 33 inches above finished floor. Grab bars
must be able to support a point load of at least 250 pounds and Minimum Quantity 1
shall be less than the allowable shear stress of the grab bar Maximum Quantity: 1
material.
Unit: Each
Minimum Estimated Cost: 448
Maximum Estimated Cost: 448
Record Number 833
Priority:

Restrooms
Finding: The left grab bar in the stall designated to be accessible in the
restroom does not extend 54 inches from the back wall.

Alternative *
Rec:
(Where
Available)

Women's Restroom at L-1

Full Rec The front end of the grab bar shall extend at least 54 inches Citation CBC 1115B.8.1; ADAAG 4.26
from the back wall and the back end of the grab bar shall be
mounted within 12 inches from the back wall. Grab bars must
be able to support a point load of at least 250 pounds and shall Minimum Quantity 1
be less than the allowable shear stress of the grab bar material. Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 531
Maximum Estimated Cost: 531
Record Number 834
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 397 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The location of the toilet paper dispenser in the stall designated
to be accessible in the restroom is not within 12 inches of the
front edge of the toilet seat.

Alternative *
Rec:
(Where
Available)

Women's Restroom at L-1

Full Rec Remount the toilet paper dispenser in the stall designated to be Citation CBC 1115B.9.3; ADAAG 4.16.6
accessible in the restroom so that it is within 12 inches from the
front edge of the toilet seat and does not encroach more than
four inches from the face of the wall (see CBC 1115B.9.3 and Minimum Quantity 1
ADAAG Figure 29(b)). Toilet paper dispensers must allow Maximum Quantity: 1
continuous paper flow and shall not interfere with the use of the
side grab bar. Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 835
Priority:

Restrooms
Finding: The flush control on the toilet in the stall designated to be
accessible in the restroom is not on the wide (approach) side of
the toilet.

Alternative *
Rec:
(Where
Available)

Women's Restroom at L-1

Full Rec Relocate the flush control on the toilet in the stall designated to Citation ADAAG 4.16.5; ADAAG 4.27.4
be accessible in the restroom so that it is on the wide
(approach) side of the toilet area (see ADAAG 4.16.5). Flush
controls shall be hand-operated or automatic mechanisms. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 127
Maximum Estimated Cost: 127
Record Number 836
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 398 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The distance from the center of the toilet to the nearest side
wall in the stall designated to be accessible in the restroom is
less than 18 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom at L-1

Full Rec Relocate the toilet or stall side wall so that the distance from the Citation CBC 1115B.7.1.3 ADAAG 4.17.3
centerline of the toilet to the nearest side wall in the stall
designated to be accessible in the restroom is exactly 18 inches
(see ADAAG Figure 28. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1143
Maximum Estimated Cost: 1143
Record Number 837
Priority:

Restrooms
Finding: The seat cover dispenser in the stall designated to be
accessible in the restroom is mounted at a height greater than
40 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom at L-1

Full Rec Relocate the seat cover dispenser in the stall designated to be Citation CBC 1115B.9.2
accessible in the restroom so that the height is no greater than
40 inches above the finished floor (see CBC 1115B.9.2). Make
certain that the location of the seat cover dispenser does not Minimum Quantity 1
interfere with the use of a grab bar and provides sufficient clear Maximum Quantity: 1
floor space.
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 838
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 399 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the rim surface of the lavatory designated to be
accessible in the restroom is greater than 34 inches above the
finished floor.

Alternative *
Rec:
(Where
Available)

Women's Restroom at L-1

Full Rec Relocate or replace the lavatory designated to be accessible in Citation ADAAG 4.19.2
the restroom to provide a maximum rim surface height of no
greater than 34 inches above the finished floor (see ADAAG
4.19.2). Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1286
Maximum Estimated Cost: 1286
Record Number 839
Priority:

Restrooms
Finding: The height of the controls and operating mechanisms for the
soap dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom at L-1

Full Rec Relocate the soap dispenser in the restroom to a maximum Citation CBC 1115B.9.2; ADAAG A4.27
height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 840
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 400 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the controls and operating mechanisms for the
paper towel dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom at L-1

Full Rec Relocate the paper towel dispenser in the restroom to a Citation CBC 1115B.9.2; ADAAG A4.27
maximum height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 841
Priority:

Restrooms
Finding: The signage indicating accessibility on the latch side of the
entry door of the restroom does not include Braille or raised
lettering and is not centered at 60 inches above the floor
surface. The gender use signage on the entrance door is not
centered at 60 inches above the floor surface.

Alternative *
Rec:
(Where
Available)

Women's Restroom at the Carnival Area

Full Rec The restroom is designated accessible and should be made Citation CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7));
accessible for the facility. Post signage centered 60 inches ADAAG 4.1.6(3)(e); ADAAG 4.30
above the ground surface on the latch side of the entrance door
identifying the restroom as accessible upon completion of the Minimum Quantity 1
following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG Maximum Quantity: 1
4.1.6(3)(e). Signage shall include Braille and raised lettering,
the gender or unisex use symbol and the ISA symbol. Post Title Unit: Each
24 gender use signage on the door @ 60" o.c. a.f.f. Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 641
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 401 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The bottom 10 inches of the door does not provide a smooth,
uninterrupted surface, or panel to allow the door to be opened
by a wheelchair footrest without creating a trap or hazardous
condition, due to the door stop.

Alternative *
Rec:
(Where
Available)

Women's Restroom at the Carnival Area

Full Rec Install a panel or replace the door to provide a smooth, Citation CBC 1133B.2.6
uninterrupted surface for the bottom 10 inches of the door.

Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 642
Priority:

Restrooms
Finding: The height of the side grab bar in the stall designated to be
accessible of the restroom is less than 33 inches above the
finished floor.

Alternative *
Rec:
(Where
Available)

Women's Restroom at the Carnival Area

Full Rec Remount the side grab bar in the stall designated to be Citation CBC 1115B.8.1; ADAAG 4.26
accessible in the restroom so that the height of the gripping
surface is centered at 33 inches above finished floor. Grab bars
must be able to support a point load of at least 250 pounds and Minimum Quantity 1
shall be less than the allowable shear stress of the grab bar Maximum Quantity: 1
material.
Unit: Each
Minimum Estimated Cost: 448
Maximum Estimated Cost: 448
Record Number 643
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 402 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The location of the toilet paper dispenser in the stall designated
to be accessible in the restroom is not within 12 inches of the
front edge of the toilet seat.

Alternative *
Rec:
(Where
Available)

Women's Restroom at the Carnival Area

Full Rec Remount the toilet paper dispenser in the stall designated to be Citation CBC 1115B.9.3; ADAAG 4.16.6
accessible in the restroom so that it is within 12 inches from the
front edge of the toilet seat (see CBC 1115B.9.3 and ADAAG
Figure 29(b)). Toilet paper dispensers must allow continuous Minimum Quantity 1
paper flow and shall not interfere with the use of the side grab Maximum Quantity: 1
bar.
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 644
Priority:

Restrooms
Finding: The distance from the center of the toilet to the nearest side
wall in the stall designated to be accessible in the restroom is
less than 18 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom at the Carnival Area

Full Rec Relocate the toilet or stall side wall so that the distance from the Citation CBC 1115B.7.1.3 ADAAG 4.17.3
centerline of the toilet to the nearest side wall in the stall
designated to be accessible in the restroom is exactly 18 inches
(see ADAAG Figure 28. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1143
Maximum Estimated Cost: 1143
Record Number 645
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 403 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The bottom edge of the reflecting surface of the mirror in the
restroom is greater than 40 inches above the finished floor.

Alternative *
Rec:
(Where
Available)

Women's Restroom at the Carnival Area

Full Rec Lower the mirror in the restroom so that the bottom edge of the Citation ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG
reflecting surface is no higher than 40 inches above the finished 4.19.6
floor and the topmost portion of the reflecting surface extends at
least 74 inches above the finished floor (see ADAAG A4.19.6). Minimum Quantity 1
A single, full-length mirror is recommended since it can Maximum Quantity: 1
accommodate all people. Make certain to provide a minimum
clear floor space in front of the mirror of 30 inches in width and Unit: Each
48 inches in length. Minimum Estimated Cost: 291
Maximum Estimated Cost: 291
Record Number 646
Priority:

Restrooms
Finding: The height of the controls and operating mechanisms for the
soap dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom at the Carnival Area

Full Rec Relocate the soap dispenser in the restroom to a maximum Citation CBC 1115B.9.2; ADAAG A4.27
height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 647
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 404 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the controls and operating mechanisms for the
paper towel dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom at the Carnival Area

Full Rec Relocate the paper towel dispenser in the restroom to a Citation CBC 1115B.9.2; ADAAG A4.27
maximum height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 648
Priority:

Restrooms
Finding: There is no signage indicating accessibility on the latch side of
the entry door of the restroom. There is no Title 24 gender use
signage on the entrance door.

Alternative *
Rec:
(Where
Available)

Women's Restroom at the Delta Speedway

Full Rec The restroom is designated accessible and should be made Citation CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7));
accessible for the facility. Post signage centered 60 inches ADAAG 4.1.6(3)(e); ADAAG 4.30
above the ground surface on the latch side of the entrance door
identifying the restroom as accessible upon completion of the Minimum Quantity 1
following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG Maximum Quantity: 1
4.1.6(3)(e). Signage shall include Braille and raised lettering,
the gender or unisex use symbol and the ISA symbol. Post Title Unit: Each
24 gender use signage on the door @ 60" o.c. a.f.f. Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 403
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 405 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: There are 14 stalls located in the multiple accommodation
restroom.

Alternative *
Rec:
(Where
Available)

Women's Restroom at the Delta Speedway

Full Rec Create an accessible 36-inch wide alternate stall in addition to Citation CBC 1115B.7.1.4; ADAAG A4.17.3; ADAAG
the required accessible standard stall in the multiple 4.22.4
accommodation restroom. The accessible 36-inch wide
alternate stall shall include an outward swinging, self-closing Minimum Quantity 1
door and parallel side grab bars and shall provide at least 66 Maximum Quantity: 1
inches in length for a stall with a wall-mounted toilet or at least
69 inches in length for a stall with a floor-mounted toilet. Unit: Each
Minimum Estimated Cost: 4000
Maximum Estimated Cost: 4000
Record Number 404
Priority:

Restrooms
Finding: There is insufficient clear floor space in the stall designated to
be accessible in the restroom. The door to the stall designated
to be accessible in the restroom does not have accessible
hardware.

Alternative *
Rec:
(Where
Available)

Women's Restroom at the Delta Speedway

Full Rec Modify or replace the stall designated to be accessible in the Citation CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
restroom so that it complies with ADAAG 4.17.3, CBC 1115B
and CBC Figures 11B-1A and 1B. Standard accessible stalls
require 60 inches in width with 56 inches depth for wall-mounted Minimum Quantity 1
toilets or 59 inches depth for floor-mounted toilets to Maximum Quantity: 1
accommodate individuals in wheelchairs. The minimum width of
a front-approach doorway shall provide at least 32 inches and a Unit: Each
side-approach doorway shall provide at least 34 inches. The Minimum Estimated Cost: 4000
door shall swing outward, close automatically and provide
accessible hardware. Maximum Estimated Cost: 4000
Record Number 405
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 406 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the side grab bar in the stall designated to be
accessible of the restroom is greater than 33 inches above the
finished floor.

Alternative *
Rec:
(Where
Available)

Women's Restroom at the Delta Speedway

Full Rec Remount the side grab bar in the stall designated to be Citation CBC 1115B.8.1; ADAAG 4.26
accessible in the restroom so that the height of the gripping
surface is centered at 33 inches above finished floor. Grab bars
must be able to support a point load of at least 250 pounds and Minimum Quantity 1
shall be less than the allowable shear stress of the grab bar Maximum Quantity: 1
material.
Unit: Each
Minimum Estimated Cost: 448
Maximum Estimated Cost: 448
Record Number 406
Priority:

Restrooms
Finding: The side grab bar in the stall designated to be accessible in the
restroom does not extend 54 inches from the back wall.

Alternative *
Rec:
(Where
Available)

Women's Restroom at the Delta Speedway

Full Rec The front end of the grab bar shall extend at least 54 inches Citation CBC 1115B.8.1; ADAAG 4.26
from the back wall and the back end of the grab bar shall be
mounted within 12 inches from the back wall. Grab bars must
be able to support a point load of at least 250 pounds and shall Minimum Quantity 1
be less than the allowable shear stress of the grab bar material. Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 531
Maximum Estimated Cost: 531
Record Number 407
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 407 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The distance from the center of the toilet to the nearest side
wall in the stall designated to be accessible in the restroom is
less than 18 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom at the Delta Speedway

Full Rec Relocate the toilet or stall side wall so that the distance from the Citation CBC 1115B.7.1.3 ADAAG 4.17.3
centerline of the toilet to the nearest side wall in the stall
designated to be accessible in the restroom is exactly 18 inches
(see ADAAG Figure 28. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1143
Maximum Estimated Cost: 1143
Record Number 408
Priority:

Restrooms
Finding: The knee clearance space under the lavatory designated to be
accessible in the restroom is less than 29 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom at the Delta Speedway

Full Rec Raise or replace the lavatory designated to be accessible in the Citation ADAAG 4.19.2
restroom to provide at least 29 inches of clear knee space
between the finished floor and bottom of the lavatory apron.
Make sure to provide at least 27 inches at 8 inches under the Minimum Quantity 1
apron (see ADAAG 4.19.2). Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1286
Maximum Estimated Cost: 1286
Record Number 409
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 408 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The pipes under the lavatory in the restroom do not provide
protection against contact.

Alternative *
Rec:
(Where
Available)

Women's Restroom at the Delta Speedway

Full Rec Insulate or otherwise configure pipes under the lavatory Citation ADAAG 4.19.4
designated to be accessible in the restroom to protect against
contact (see ADAAG 4.19.4). Make certain there are no sharp
or abrasive surfaces under the lavatory. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 39
Maximum Estimated Cost: 39
Record Number 410
Priority:

Restrooms
Finding: The height of the controls and operating mechanisms for the
soap dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom at the Delta Speedway

Full Rec Relocate the soap dispenser in the restroom to a maximum Citation CBC 1115B.9.2; ADAAG A4.27
height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 411
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 409 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the controls and operating mechanisms for the
paper towel dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom at the Delta Speedway

Full Rec Relocate the paper towel dispenser in the restroom to a Citation CBC 1115B.9.2; ADAAG A4.27
maximum height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 412
Priority:

Restrooms
Finding: The height of the controls and operating mechanisms for the
hand dryer in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom at the Delta Speedway

Full Rec Relocate the hand dryer in the restroom to a maximum height of Citation CBC 1115B.9.2; ADAAG A4.27
40 inches for all the controls and operating mechanisms (see
CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 413
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 410 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The signage indicating accessibility at the entry door of the
restroom is not mounted on the latch side of the entrance door
and is not centered at 60 inches above the floor surface. There
is no Title 24 gender use signage on the entrance door.

Alternative *
Rec:
(Where
Available)

Women's Restroom at the First Floor of the Grandstands

Full Rec The restroom is designated accessible and should be made Citation CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7));
accessible for the facility, incorporating children's height ADAAG 4.1.6(3)(e); ADAAG 4.30
standards set forth in the Final Rule amending ADAAG, January
13, 1998. Post signage centered 60 inches above the ground Minimum Quantity 1
surface on the latch side of the entrance door identifying the Maximum Quantity: 1
restroom as accessible upon completion of the following items
(see CBC 1115B., ADAAG 4.1.2(7) and ADAAG 4.1.6(3)(e). Unit: Each
Signage shall include Braille and raised lettering, the gender or Minimum Estimated Cost: 58
unisex use symbol and the ISA symbol. Post Title 24 gender
use signage on the door @ 60" o.c. a.f.f. Maximum Estimated Cost: 58
Record Number 615
Priority:

Restrooms
Finding: The bottom 10 inches of the door does not provide a smooth,
uninterrupted surface, or panel to allow the door to be opened
by a wheelchair footrest without creating a trap or hazardous
condition, due to the door stop.

Alternative *
Rec:
(Where
Available)

Women's Restroom at the First Floor of the Grandstands

Full Rec Install a panel or replace the door to provide a smooth, Citation CBC 1133B.2.6
uninterrupted surface for the bottom 10 inches of the door.

Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 616
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 411 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The door to the alternate stall designated to be accessible in the
restroom does not close automatically or have accessible
hardware. The inside handle on the standard stall door
designated to be accessible in the restroom is not mounted
immediately below the latch.

Alternative *
Rec:
(Where
Available)

Women's Restroom at the First Floor of the Grandstands

Full Rec Provide an automatic door closer, spring hinge, pull bar or Citation ADAAG A4.17.5
accessible handle mounted on the inside of the stall door to the
stall designated to be accessible in the restroom (see ADAAG
A4.17.5). Accessible hardware on the inside and outside of the Minimum Quantity 1
stall designated to be accessible door shall be equipped with a Maximum Quantity: 1
loop or U-shaped handle mounted immediately below the latch.
The latch shall be flip-over style, sliding or other hardware not Unit: Each
requiring grasping or twisting. Make certain that the inside and Minimum Estimated Cost: 269
outside door hardware is mounted no more than 48 inches
above the finished floor (see CBC 115B.7.1.3 and ADAAG Maximum Estimated Cost: 269
4.13.9). Record Number 617
Priority:

Restrooms
Finding: The height of the side grab bar in the standard stall designated
to be accessible of the restroom is less than 33 inches above
the finished floor.

Alternative *
Rec:
(Where
Available)

Women's Restroom at the First Floor of the Grandstands

Full Rec Remount the side grab bar in the stall designated to be Citation CBC 1115B.8.1; ADAAG 4.26
accessible in the restroom so that the height of the gripping
surface is centered at 33 inches above finished floor. Grab bars
must be able to support a point load of at least 250 pounds and Minimum Quantity 1
shall be less than the allowable shear stress of the grab bar Maximum Quantity: 1
material.
Unit: Each
Minimum Estimated Cost: 448
Maximum Estimated Cost: 448
Record Number 618
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 412 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The distance from the end of the back grab bar to the nearest
side wall in the standard stall designated to be accessible of the
restroom is greater than 6 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom at the First Floor of the Grandstands

Full Rec Remount the back grab bar in the stall designated to be Citation ADAAG 4.26; CBC 1115B.8.1
accessible in the restroom so that it is not more than 6 inches
from the nearest side wall (see ADAAG 4.26 and CBC Figure
11B.1A-1C). Grab bars must be able to support a point load of Minimum Quantity 1
at least 250 pounds and shall be less than the allowable shear Maximum Quantity: 1
stress of the grab bar material.
Unit: Each
Minimum Estimated Cost: 448
Maximum Estimated Cost: 448
Record Number 619
Priority:

Restrooms
Finding: The side grab bars in the standard stall and the alternate stall
designated to be accessible in the restroom do not extend 54
inches from the back wall.

Alternative *
Rec:
(Where
Available)

Women's Restroom at the First Floor of the Grandstands

Full Rec The front end of the grab bars shall extend at least 54 inches Citation CBC 1115B.8.1; ADAAG 4.26
from the back wall and the back end of the grab bar shall be
mounted within 12 inches from the back wall. Grab bars must
be able to support a point load of at least 250 pounds and shall Minimum Quantity 1
be less than the allowable shear stress of the grab bar material. Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 531
Maximum Estimated Cost: 531
Record Number 620
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 413 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The distance from the center of the toilet to the nearest side
wall in the standard stall designated to be accessible in the
restroom is greater than 18 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom at the First Floor of the Grandstands

Full Rec Relocate the toilet or stall side wall so that the distance from the Citation CBC 1115B.7.1.3 ADAAG 4.17.3
centerline of the toilet to the nearest side wall in the stall
designated to be accessible in the restroom is exactly 18 inches
(see ADAAG Figure 28. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1143
Maximum Estimated Cost: 1143
Record Number 621
Priority:

Restrooms
Finding: The height of the controls and operating mechanisms for the
soap dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom at the First Floor of the Grandstands

Full Rec Relocate the soap dispenser in the restroom to a maximum Citation CBC 1115B.9.2; ADAAG A4.27
height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 622
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 414 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the controls and operating mechanisms for the
paper towel dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom at the First Floor of the Grandstands

Full Rec Relocate the paper towel dispenser in the restroom to a Citation CBC 1115B.9.2; ADAAG A4.27
maximum height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 623
Priority:

Restrooms
Finding: The signage on the latch side of the entry door of the restroom
does not include the International Symbol of Accessibility.
There is no Title 24 gender use signage on the entrance door.

Alternative *
Rec:
(Where
Available)

Women's Restroom at the Soccer Field

Full Rec The restroom is designated accessible and should be made Citation CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7));
accessible for the facility. Post signage centered 60 inches ADAAG 4.1.6(3)(e); ADAAG 4.30
above the ground surface on the latch side of the entrance door
identifying the restroom as accessible upon completion of the Minimum Quantity 1
following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG Maximum Quantity: 1
4.1.6(3)(e). Signage shall include Braille and raised lettering,
the gender or unisex use symbol and the ISA symbol. Post Title Unit: Each
24 gender use signage on the door @ 60" o.c. a.f.f. Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 897
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 415 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: There is less than 12 inches of clearance on the latch side of
the exterior entrance door from the push side.

Alternative *
Rec:
(Where
Available)

Women's Restroom at the Soccer Field

Full Rec Provide at least 12 inches of latch side clearance at the Citation ADAAG 4.13.6
entrance door (see ADAAG 4.13.6 and Figure 25). Otherwise,
install an automatic door opening device.
Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 898
Priority:

Restrooms
Finding: The door opening force for the exterior door is greater than 5
pounds of force.

Alternative *
Rec:
(Where
Available)

Women's Restroom at the Soccer Field

Full Rec Adjust the closers on all exterior doors to a maximum door Citation CBC 1133B.2.5; ADAAG 4.13.11
opening force of 5 pounds of force (see ADAAG 4.13.11 and
CBC 1133B.2.5).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 5
Maximum Estimated Cost: 5
Record Number 899
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 416 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: There is no signage indicating accessibility on the latch side of
the entry door of the restroom. The gender use signage on the
entrance door is not centered at 60 inches above the floor
surface and does not include Braille or the ISA symbol.

Alternative *
Rec:
(Where
Available)

Women's Restroom in Building 3

Full Rec The restroom is designated accessible and should be made Citation CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7));
accessible for the facility. Post signage centered 60 inches ADAAG 4.1.6(3)(e); ADAAG 4.30
above the ground surface on the latch side of the entrance door
identifying the restroom as accessible upon completion of the Minimum Quantity 1
following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG Maximum Quantity: 1
4.1.6(3)(e). Signage shall include Braille and raised lettering,
the gender or unisex use symbol and the ISA symbol. Post Title Unit: Each
24 gender use signage on the door @ 60" o.c. a.f.f. Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 996
Priority:

Restrooms
Finding: The clear opening width of the entrance doorway to the
restroom is less than 32 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom in Building 3

Full Rec Widen the entrance doorway to the restroom to provide a clear Citation ADAAG 4.13.5
opening width of at least 32 inches when the door is open 90
degrees (see ADAAG 4.13.5).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 750
Maximum Estimated Cost: 750
Record Number 997
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 417 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The entrance door to the restroom has a round doorknob that
requires tight grasping or twisting of the wrist to operate.

Alternative *
Rec:
(Where
Available)

Women's Restroom in Building 3

Full Rec Replace the door hardware mounted on the restroom complying Citation ADAAG 4.13.9
with ADAAG 4.13.9. Make certain accessible door hardware is
mounted no higher than 48 inches above the finished floor.
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 204
Maximum Estimated Cost: 204
Record Number 998
Priority:

Restrooms
Finding: The bottom 10 inches of the door does not provide a smooth,
uninterrupted surface, or panel to allow the door to be opened
by a wheelchair footrest without creating a trap or hazardous
condition, due to the doorstop.

Alternative *
Rec:
(Where
Available)

Women's Restroom in Building 3

Full Rec Install a panel or replace the door to provide a smooth, Citation CBC 1133B.2.6
uninterrupted surface for the bottom 10 inches of the door.

Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 999
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 418 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The inside handle on the stall door is not mounted immediately
below the latch.

Alternative *
Rec:
(Where
Available)

Women's Restroom in Building 3

Full Rec Install a loop or U-shaped handle immediately below the latch Citation CBC 1115B.7.1.3; ADAAG 4.13.9
hardware on the door to the stall designated to be accessible in
the restroom (see CBC 1115B.7.1.3 and ADAAG 4.13.9). Lever-
operated or push-type mechanisms may also be used. The latch Minimum Quantity 1
shall be flip-over style, sliding or other hardware not requiring Maximum Quantity: 1
grasping or twisting.
Unit: Each
Minimum Estimated Cost: 189
Maximum Estimated Cost: 189
Record Number 1000
Priority:

Restrooms
Finding: The height of the coat hook on the stall door designated to be
accessible in the restroom is greater than 48 inches above the
floor surface.

Alternative *
Rec:
(Where
Available)

Women's Restroom in Building 3

Full Rec Remount the coat hook on the stall door designated to be Citation CBC 1115B.9.2; ADAAG A4.27
accessible in the restroom to a maximum height of 48 inches
above the floor surface.
Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 1001
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 419 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the back grab bar in the stall designated to be
accessible of the restroom is less than 33 inches above the
finished floor.

Alternative *
Rec:
(Where
Available)

Women's Restroom in Building 3

Full Rec Remount the back grab bar in the stall designated to be Citation CBC 1115B.8.1; ADAAG 4.26
accessible in the restroom so that the height of the gripping
surface is centered at 33 inches above finished floor. Grab bars
must be able to support a point load of at least 250 pounds and Minimum Quantity 1
shall be less than the allowable shear stress of the grab bar Maximum Quantity: 1
material.
Unit: Each
Minimum Estimated Cost: 448
Maximum Estimated Cost: 448
Record Number 1002
Priority:

Restrooms
Finding: The side grab bar in the stall designated to be accessible in the
restroom does not extend 54 inches from the back wall.

Alternative *
Rec:
(Where
Available)

Women's Restroom in Building 3

Full Rec The front end of the grab bar shall extend at least 54 inches Citation CBC 1115B.8.1; ADAAG 4.26
from the back wall and the back end of the grab bar shall be
mounted within 12 inches from the back wall. Grab bars must
be able to support a point load of at least 250 pounds and shall Minimum Quantity 1
be less than the allowable shear stress of the grab bar material. Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 531
Maximum Estimated Cost: 531
Record Number 1003
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 420 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The location of the toilet paper dispenser in the stall designated
to be accessible in the restroom is not within 12 inches of the
front edge of the toilet seat. The toilet paper dispenser
protrudes more than 4 inches from the side wall and interferes
with the clear floor space of the water closet.

Alternative *
Rec:
(Where
Available)

Women's Restroom in Building 3

Full Rec Remount the toilet paper dispenser in the stall designated to be Citation CBC 1115B.9.3; ADAAG 4.16.6
accessible in the restroom so that it is within 12 inches from the
front edge of the toilet seat and does not encroach more than
four inches from the face of the wall (see CBC 1115B.9.3 and Minimum Quantity 1
ADAAG Figure 29(b)). Toilet paper dispensers must allow Maximum Quantity: 1
continuous paper flow and shall not interfere with the use of the
side grab bar. Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 1004
Priority:

Restrooms
Finding: The flush control on the toilet in the stall designated to be
accessible in the restroom is not on the wide (approach) side of
the toilet.

Alternative *
Rec:
(Where
Available)

Women's Restroom in Building 3

Full Rec Relocate the flush control on the toilet in the stall designated to Citation ADAAG 4.16.5; ADAAG 4.27.4
be accessible in the restroom so that it is on the wide
(approach) side of the toilet area (see ADAAG 4.16.5). Flush
controls shall be hand-operated or automatic mechanisms. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 127
Maximum Estimated Cost: 127
Record Number 1005
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 421 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the toilet seat in the stall designated to be
accessible in the restroom is less than 17 inches above the
finished floor.

Alternative *
Rec:
(Where
Available)

Women's Restroom in Building 3

Full Rec Remove or modify the toilet in the stall designated to be Citation ADAAG 4.16.3
accessible in the restroom so that the seat height is between 17
inches and 19 inches above the finished floor (see ADAAG
4.16.3). Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1707
Maximum Estimated Cost: 1707
Record Number 1006
Priority:

Restrooms
Finding: The distance from the center of the toilet to the nearest side
wall in the stall designated to be accessible in the restroom is
greater than 18 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom in Building 3

Full Rec Relocate the toilet or stall side wall so that the distance from the Citation CBC 1115B.7.1.3 ADAAG 4.17.3
centerline of the toilet to the nearest side wall in the stall
designated to be accessible in the restroom is exactly 18 inches
(see ADAAG Figure 28. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1143
Maximum Estimated Cost: 1143
Record Number 1007
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 422 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: There is no clear floor space provided in front of the seat cover
dispenser.

Alternative *
Rec:
(Where
Available)

Women's Restroom in Building 3

Full Rec Relocate the seat cover dispenser in the stall designated to be Citation CBC 1115B.9.2
accessible in the restroom so that the height is no greater than
40 inches above the finished floor (see CBC 1115B.9.2). Make
certain that the location of the seat cover dispenser does not Minimum Quantity 1
interfere with the use of a grab bar and provides sufficient clear Maximum Quantity: 1
floor space.
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 1008
Priority:

Restrooms
Finding: The faucet controls on the lavatory in the restroom require tight
grasping, pinching, or twisting of the wrist and are not
accessible.

Alternative *
Rec:
(Where
Available)

Women's Restroom in Building 3

Full Rec Install faucet controls complying with ADAAG 4.19.5 on the Citation ADAAG 4.19.5
lavatory designated to be accessible in the restroom. Lever-
operated, push-type, touch-type or electronically controlled
mechanisms are acceptable elements (see ADAAG 4.19.5). If Minimum Quantity 1
self-closing valves are used the faucet shall remain open for at Maximum Quantity: 1
least 10 seconds.
Unit: Each
Minimum Estimated Cost: 392
Maximum Estimated Cost: 392
Record Number 1009
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 423 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The knee clearance space under the lavatory designated to be
accessible in the restroom is less than 29 inches. The knee
depth space under the lavatory designated to be accessible in
the restroom is less than 27 inches at 8 inches under the
lavatory apron.

Alternative *
Rec:
(Where
Available)

Women's Restroom in Building 3

Full Rec Replace the lavatory designated to be accessible in the Citation ADAAG 4.19.2
restroom to provide at least 29 inches of clear knee space
between the finished floor and bottom of the lavatory apron.
Make sure to provide at least 27 inches at 8 inches under the Minimum Quantity 1
apron (see ADAAG 4.19.2). Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1286
Maximum Estimated Cost: 1286
Record Number 1010
Priority:

Restrooms
Finding: The pipes under the lavatory in the restroom do not provide
protection against contact.

Alternative *
Rec:
(Where
Available)

Women's Restroom in Building 3

Full Rec Insulate or otherwise configure pipes under the lavatory Citation ADAAG 4.19.4
designated to be accessible in the restroom to protect against
contact (see ADAAG 4.19.4). Make certain there are no sharp
or abrasive surfaces under the lavatory. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 39
Maximum Estimated Cost: 39
Record Number 1011
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 424 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The bottom edge of the reflecting surface of the mirror in the
restroom is greater than 40 inches above the finished floor.

Alternative *
Rec:
(Where
Available)

Women's Restroom in Building 3

Full Rec Lower the mirror in the restroom so that the bottom edge of the Citation ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG
reflecting surface is no higher than 40 inches above the finished 4.19.6
floor and the topmost portion of the reflecting surface extends at
least 74 inches above the finished floor (see ADAAG A4.19.6). Minimum Quantity 1
A single, full-length mirror is recommended since it can Maximum Quantity: 1
accommodate all people. Make certain to provide a minimum
clear floor space in front of the mirror of 30 inches in width and Unit: Each
48 inches in length. Minimum Estimated Cost: 291
Maximum Estimated Cost: 291
Record Number 1012
Priority:

Restrooms
Finding: The height of the controls and operating mechanisms for the
soap dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom in Building 3

Full Rec Relocate the soap dispenser in the restroom to a maximum Citation CBC 1115B.9.2; ADAAG A4.27
height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 1013
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 425 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the controls and operating mechanisms for the
paper towel dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom in Building 3

Full Rec Relocate the paper towel dispenser in the restroom to a Citation CBC 1115B.9.2; ADAAG A4.27
maximum height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 1014
Priority:

Restrooms
Finding: There is no signage indicating accessibility on the latch side of
the entry door of the restroom. There is no Title 24 gender use
signage on the entrance door.

Alternative *
Rec:
(Where
Available)

Women's Restroom in the Jockey Annex

Full Rec The restroom is designated accessible and should be made Citation CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7));
accessible for the facility. Post signage centered 60 inches ADAAG 4.1.6(3)(e); ADAAG 4.30
above the ground surface on the latch side of the entrance door
identifying the restroom as accessible upon completion of the Minimum Quantity 1
following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG Maximum Quantity: 1
4.1.6(3)(e). Signage shall include Braille and raised lettering,
the gender or unisex use symbol and the ISA symbol. Post Title Unit: Each
24 gender use signage on the door @ 60" o.c. a.f.f. Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 480
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 426 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The entrance door to the restroom has a round doorknob that
requires tight grasping or twisting of the wrist to operate.

Alternative *
Rec:
(Where
Available)

Women's Restroom in the Jockey Annex

Full Rec Replace the door hardware mounted on the restroom complying Citation ADAAG 4.13.9
with ADAAG 4.13.9. Make certain accessible door hardware is
mounted no higher than 48 inches above the finished floor.
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 204
Maximum Estimated Cost: 204
Record Number 481
Priority:

Restrooms
Finding: There is insufficient clear floor space in the stall designated to
be accessible in the restroom. There is no door on the stall
designated to be accessible in the restroom.

Alternative *
Rec:
(Where
Available)

Women's Restroom in the Jockey Annex

Full Rec Modify or replace the stall designated to be accessible in the Citation CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
restroom so that it complies with ADAAG 4.17.3, CBC 1115B
and CBC Figures 11B-1A and 1B. Standard accessible stalls
require 60 inches in width with 56 inches depth for wall-mounted Minimum Quantity 1
toilets or 59 inches depth for floor-mounted toilets to Maximum Quantity: 1
accommodate individuals in wheelchairs. The minimum width of
a front-approach doorway shall provide at least 32 inches and a Unit: Each
side-approach doorway shall provide at least 34 inches. The Minimum Estimated Cost: 4000
door shall swing outward, close automatically and provide
accessible hardware. Maximum Estimated Cost: 4000
Record Number 482
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 427 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: There are no grab bars in the stall designated to be accessible
in the restroom.

Alternative *
Rec:
(Where
Available)

Women's Restroom in the Jockey Annex

Full Rec Install one 36-inch back grab bar and one 42/48-inch side grab Citation CBC 1115B.8; ADAAG 4.26
bar in the stall designated to be accessible in the restroom.
Grab bars shall be mounted at a height of 33 inches above the
finished floor. Grab bars must be able to support a point load of Minimum Quantity 1
at least 250 pounds and shall be less than the allowable shear Maximum Quantity: 1
stress of the grab bar material.
Unit: Each
Minimum Estimated Cost: 531
Maximum Estimated Cost: 531
Record Number 483
Priority:

Restrooms
Finding: The height of the toilet seat in the stall designated to be
accessible in the restroom is less than 17 inches above the
finished floor.

Alternative *
Rec:
(Where
Available)

Women's Restroom in the Jockey Annex

Full Rec Remove or modify the toilet in the stall designated to be Citation ADAAG 4.16.3
accessible in the restroom so that the seat height is between 17
inches and 19 inches above the finished floor (see ADAAG
4.16.3). Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1707
Maximum Estimated Cost: 1707
Record Number 484
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 428 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The distance from the center of the toilet to the nearest side
wall in the stall designated to be accessible in the restroom is
less than 18 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom in the Jockey Annex

Full Rec Relocate the toilet or stall side wall so that the distance from the Citation CBC 1115B.7.1.3 ADAAG 4.17.3
centerline of the toilet to the nearest side wall in the stall
designated to be accessible in the restroom is exactly 18 inches
(see ADAAG Figure 28. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1143
Maximum Estimated Cost: 1143
Record Number 485
Priority:

Restrooms
Finding: The seat cover dispenser in the stall designated to be
accessible in the restroom is mounted at a height greater than
40 inches and there is no clear floor space.

Alternative *
Rec:
(Where
Available)

Women's Restroom in the Jockey Annex

Full Rec Relocate the seat cover dispenser in the stall designated to be Citation CBC 1115B.9.2
accessible in the restroom so that the height is no greater than
40 inches above the finished floor (see CBC 1115B.9.2). Make
certain that the location of the seat cover dispenser does not Minimum Quantity 1
interfere with the use of a grab bar and provides sufficient clear Maximum Quantity: 1
floor space.
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 486
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 429 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The faucet controls on the lavatory in the restroom require tight
grasping, pinching, or twisting of the wrist and are not
accessible.

Alternative *
Rec:
(Where
Available)

Women's Restroom in the Jockey Annex

Full Rec Install faucet controls complying with ADAAG 4.19.5 on the Citation ADAAG 4.19.5
lavatory designated to be accessible in the restroom. Lever-
operated, push-type, touch-type or electronically controlled
mechanisms are acceptable elements (see ADAAG 4.19.5). If Minimum Quantity 1
self-closing valves are used the faucet shall remain open for at Maximum Quantity: 1
least 10 seconds.
Unit: Each
Minimum Estimated Cost: 392
Maximum Estimated Cost: 392
Record Number 487
Priority:

Restrooms
Finding: The knee clearance space under the lavatory designated to be
accessible in the restroom is less than 29 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom in the Jockey Annex

Full Rec Raise or replace the lavatory designated to be accessible in the Citation ADAAG 4.19.2
restroom to provide at least 29 inches of clear knee space
between the finished floor and bottom of the lavatory apron.
Make sure to provide at least 27 inches at 8 inches under the Minimum Quantity 1
apron (see ADAAG 4.19.2). Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1286
Maximum Estimated Cost: 1286
Record Number 488
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 430 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The pipes under the lavatory in the restroom do not provide
protection against contact.

Alternative *
Rec:
(Where
Available)

Women's Restroom in the Jockey Annex

Full Rec Insulate or otherwise configure pipes under the lavatory Citation ADAAG 4.19.4
designated to be accessible in the restroom to protect against
contact (see ADAAG 4.19.4). Make certain there are no sharp
or abrasive surfaces under the lavatory. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 39
Maximum Estimated Cost: 39
Record Number 489
Priority:

Restrooms
Finding: The bottom edge of the reflecting surface of the mirror in the
restroom is greater than 40 inches above the finished floor.

Alternative *
Rec:
(Where
Available)

Women's Restroom in the Jockey Annex

Full Rec Lower the mirror in the restroom so that the bottom edge of the Citation ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG
reflecting surface is no higher than 40 inches above the finished 4.19.6
floor and the topmost portion of the reflecting surface extends at
least 74 inches above the finished floor (see ADAAG A4.19.6). Minimum Quantity 1
A single, full-length mirror is recommended since it can Maximum Quantity: 1
accommodate all people. Make certain to provide a minimum
clear floor space in front of the mirror of 30 inches in width and Unit: Each
48 inches in length. Minimum Estimated Cost: 291
Maximum Estimated Cost: 291
Record Number 490
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 431 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the controls and operating mechanisms for the
soap dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom in the Jockey Annex

Full Rec Relocate the soap dispenser in the restroom to a maximum Citation CBC 1115B.9.2; ADAAG A4.27
height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 491
Priority:

Restrooms
Finding: The height of the controls and operating mechanisms for the
paper towel dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom in the Jockey Annex

Full Rec Relocate the paper towel dispenser in the restroom to a Citation CBC 1115B.9.2; ADAAG A4.27
maximum height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 492
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 432 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: There are no accessible shower stalls provided in the restroom.

Alternative *
Rec:
(Where
Available)

Women's Restroom in the Jockey Annex

Full Rec Since shower stalls are provided in the restroom, at least one Citation CBC 1115B.6.2; ADAAG 4.21
accessible shower stall is required. Install an accessible shower
stall complying with CBC 1115B 6.2 and ADAAG 4.21 in the
restroom. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 2853
Maximum Estimated Cost: 2853
Record Number 493
Priority:

Restrooms
Finding: There is no signage indicating accessibility on the latch side of
the entry door of the restroom. The gender use signage on the
entrance door does not include Braille or the ISA symbol.

Alternative *
Rec:
(Where
Available)

Women's Restroom in the Main Office

Full Rec The restroom is designated accessible and should be made Citation CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7));
accessible for the facility. Post signage centered 60 inches ADAAG 4.1.6(3)(e); ADAAG 4.30
above the ground surface on the latch side of the entrance door
identifying the restroom as accessible upon completion of the Minimum Quantity 1
following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG Maximum Quantity: 1
4.1.6(3)(e). Signage shall include Braille and raised lettering,
the gender or unisex use symbol and the ISA symbol. Post Title Unit: Each
24 gender use signage on the door @ 60" o.c. a.f.f. Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 1133
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 433 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: There is insufficient clear floor space in the stall designated to
be accessible in the restroom. The door to the stall designated
to be accessible in the restroom does not have accessible
hardware.

Alternative *
Rec:
(Where
Available)

Women's Restroom in the Main Office

Full Rec Modify or replace the stall designated to be accessible in the Citation CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
restroom so that it complies with ADAAG 4.17.3, CBC 1115B
and CBC Figures 11B-1A and 1B. Standard accessible stalls
require 60 inches in width with 56 inches depth for wall-mounted Minimum Quantity 1
toilets or 59 inches depth for floor-mounted toilets to Maximum Quantity: 1
accommodate individuals in wheelchairs. The minimum width of
a front-approach doorway shall provide at least 32 inches and a Unit: Each
side-approach doorway shall provide at least 34 inches. The Minimum Estimated Cost: 4000
door shall swing outward, close automatically and provide
accessible hardware. Maximum Estimated Cost: 4000
Record Number 1134
Priority:

Restrooms
Finding: The height of the coat hook on the stall door designated to be
accessible in the restroom is greater than 48 inches above the
floor surface.

Alternative *
Rec:
(Where
Available)

Women's Restroom in the Main Office

Full Rec Remount the coat hook on the stall door designated to be Citation CBC 1115B.9.2; ADAAG A4.27
accessible in the restroom to a maximum height of 48 inches
above the floor surface.
Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 1135
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 434 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the side grab bar in the stall designated to be
accessible of the restroom is greater than 33 inches above the
finished floor.

Alternative *
Rec:
(Where
Available)

Women's Restroom in the Main Office

Full Rec Remount the side grab bar in the stall designated to be Citation CBC 1115B.8.1; ADAAG 4.26
accessible in the restroom so that the height of the gripping
surface is centered at 33 inches above finished floor. Grab bars
must be able to support a point load of at least 250 pounds and Minimum Quantity 1
shall be less than the allowable shear stress of the grab bar Maximum Quantity: 1
material.
Unit: Each
Minimum Estimated Cost: 448
Maximum Estimated Cost: 448
Record Number 1136
Priority:

Restrooms
Finding: The side grab bar in the stall designated to be accessible in the
restroom does not extend 54 inches from the back wall.

Alternative *
Rec:
(Where
Available)

Women's Restroom in the Main Office

Full Rec The front end of the grab bar shall extend at least 54 inches Citation CBC 1115B.8.1; ADAAG 4.26
from the back wall and the back end of the grab bar shall be
mounted within 12 inches from the back wall. Grab bars must
be able to support a point load of at least 250 pounds and shall Minimum Quantity 1
be less than the allowable shear stress of the grab bar material. Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 531
Maximum Estimated Cost: 531
Record Number 1137
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 435 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The toilet paper dispenser protrudes more than 4 inches from
the side wall and interferes with the clear floor space of the
water closet.

Alternative *
Rec:
(Where
Available)

Women's Restroom in the Main Office

Full Rec Remount or replace the toilet paper dispenser so that it does not Citation DSA Access Policy 99-07
encroach more than four inches from the face of the wall. Make
sure it does not interfere with the use of the side grab bar (see
ADAAG 4.16.6 and Figure 29(b)). Toilet paper dispensers must Minimum Quantity 1
allow continuous paper flow and be mounted within 12" in front Maximum Quantity: 1
of the water closet.
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 1138
Priority:

Restrooms
Finding: The height of the toilet seat in the stall designated to be
accessible in the restroom is greater than 19 inches above the
finished floor.

Alternative *
Rec:
(Where
Available)

Women's Restroom in the Main Office

Full Rec Remove or modify the toilet in the stall designated to be Citation ADAAG 4.16.3
accessible in the restroom so that the seat height is between 17
inches and 19 inches above the finished floor (see ADAAG
4.16.3). Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1707
Maximum Estimated Cost: 1707
Record Number 1139
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 436 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The distance from the center of the toilet to the nearest side
wall in the stall designated to be accessible in the restroom is
greater than 18 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom in the Main Office

Full Rec Relocate the toilet or stall side wall so that the distance from the Citation CBC 1115B.7.1.3 ADAAG 4.17.3
centerline of the toilet to the nearest side wall in the stall
designated to be accessible in the restroom is exactly 18 inches
(see ADAAG Figure 28. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1143
Maximum Estimated Cost: 1143
Record Number 1140
Priority:

Restrooms
Finding: The knee clearance space under the lavatory designated to be
accessible in the restroom is less than 29 inches. The knee
depth space under the lavatory designated to be accessible in
the restroom is less than 27 inches at 8 inches under the
lavatory apron.

Alternative *
Rec:
(Where
Available)

Women's Restroom in the Main Office

Full Rec Raise or replace the lavatory designated to be accessible in the Citation ADAAG 4.19.2
restroom to provide at least 29 inches of clear knee space
between the finished floor and bottom of the lavatory apron.
Make sure to provide at least 27 inches at 8 inches under the Minimum Quantity 1
apron (see ADAAG 4.19.2). Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1286
Maximum Estimated Cost: 1286
Record Number 1141
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 437 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the controls and operating mechanisms for the
paper towel dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom in the Main Office

Full Rec Relocate the paper towel dispenser in the restroom to a Citation CBC 1115B.9.2; ADAAG A4.27
maximum height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 1142
Priority:

Restrooms
Finding: There is no signage indicating accessibility on the latch side of
the entry door of the restroom.

Alternative *
Rec:
(Where
Available)

Women's Restroom in the Maintenance Shop

Full Rec The restroom is designated accessible and should be made Citation CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7));
accessible for the facility. Post signage centered 60 inches ADAAG 4.1.6(3)(e); ADAAG 4.30
above the ground surface on the latch side of the entrance door
identifying the restroom as accessible upon completion of the Minimum Quantity 1
following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG Maximum Quantity: 1
4.1.6(3)(e). Signage shall include Braille and raised lettering,
the gender or unisex use symbol and the ISA symbol. Unit: Each
Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 414
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 438 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The clear opening width of the entrance doorway to the
restroom is less than 32 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom in the Maintenance Shop

Full Rec Widen the entrance doorway to the restroom to provide a clear Citation ADAAG 4.13.5
opening width of at least 32 inches when the door is open 90
degrees (see ADAAG 4.13.5).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 750
Maximum Estimated Cost: 750
Record Number 415
Priority:

Restrooms
Finding: The entrance door to the restroom has a round doorknob that
requires tight grasping or twisting of the wrist to operate.

Alternative *
Rec:
(Where
Available)

Women's Restroom in the Maintenance Shop

Full Rec Replace the door hardware mounted on the restroom complying Citation ADAAG 4.13.9
with ADAAG 4.13.9. Make certain accessible door hardware is
mounted no higher than 48 inches above the finished floor.
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 204
Maximum Estimated Cost: 204
Record Number 416
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 439 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The urinal in the restroom is floor mounted and does not provide
a tapered, elongated rim. The flush control valve on the urinal
is greater than 44 inches above the finished floor.

Alternative *
Rec:
(Where
Available)

Women's Restroom in the Maintenance Shop

Full Rec Replace the urinal designated to be accessible in the restroom Citation ADAAG 4.18.2
with a wall-mounted or stall-type tapered, elongated rim unit
complying with ADAAG 4.18.2. The height of the rim surface of
the urinal designated to be accessible shall not exceed 17 Minimum Quantity 1
inches above the finished floor and the flush control valve shall Maximum Quantity: 1
not exceed a height of 44 inches above the finished floor.
Unit: Each
Minimum Estimated Cost: 951
Maximum Estimated Cost: 951
Record Number 417
Priority:

Restrooms
Finding: There is insufficient clear floor space in the stall designated to
be accessible in the restroom. The stall door to the stall
designated to be accessible in the restroom swings inward
limiting the clear floor space in the stall designated to be
accessible. The door to the stall designated to be accessible in
the restroom does not close automatically or have accessible
hardware.

Alternative *
Rec:
(Where
Available)

Women's Restroom in the Maintenance Shop

Full Rec Modify or replace the stall designated to be accessible in the Citation CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
restroom so that it complies with ADAAG 4.17.3, CBC 1115B
and CBC Figures 11B-1A and 1B. Standard accessible stalls
require 60 inches in width with 56 inches depth for wall-mounted Minimum Quantity 1
toilets or 59 inches depth for floor-mounted toilets to Maximum Quantity: 1
accommodate individuals in wheelchairs. The minimum width of
a front-approach doorway shall provide at least 32 inches and a Unit: Each
side-approach doorway shall provide at least 34 inches. The Minimum Estimated Cost: 4000
door shall swing outward, close automatically and provide
accessible hardware. Maximum Estimated Cost: 4000
Record Number 418
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 440 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: There are no grab bars in the stall designated to be accessible
in the restroom.

Alternative *
Rec:
(Where
Available)

Women's Restroom in the Maintenance Shop

Full Rec Install one 36-inch back grab bar and one 42/48-inch side grab Citation CBC 1115B.8; ADAAG 4.26
bar in the stall designated to be accessible in the restroom.
Grab bars shall be mounted at a height of 33 inches above the
finished floor. Grab bars must be able to support a point load of Minimum Quantity 1
at least 250 pounds and shall be less than the allowable shear Maximum Quantity: 1
stress of the grab bar material.
Unit: Each
Minimum Estimated Cost: 531
Maximum Estimated Cost: 531
Record Number 419
Priority:

Restrooms
Finding: The flush control on the toilet in the stall designated to be
accessible in the restroom is not on the wide (approach) side of
the toilet.

Alternative *
Rec:
(Where
Available)

Women's Restroom in the Maintenance Shop

Full Rec Relocate the flush control on the toilet in the stall designated to Citation ADAAG 4.16.5; ADAAG 4.27.4
be accessible in the restroom so that it is on the wide
(approach) side of the toilet area (see ADAAG 4.16.5). Flush
controls shall be hand-operated or automatic mechanisms. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 127
Maximum Estimated Cost: 127
Record Number 420
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 441 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the toilet seat in the stall designated to be
accessible in the restroom is less than 17 inches above the
finished floor.

Alternative *
Rec:
(Where
Available)

Women's Restroom in the Maintenance Shop

Full Rec Remove or modify the toilet in the stall designated to be Citation ADAAG 4.16.3
accessible in the restroom so that the seat height is between 17
inches and 19 inches above the finished floor (see ADAAG
4.16.3). Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1707
Maximum Estimated Cost: 1707
Record Number 421
Priority:

Restrooms
Finding: The distance from the center of the toilet to the nearest side
wall in the stall designated to be accessible in the restroom is
less than 18 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom in the Maintenance Shop

Full Rec Relocate the toilet or stall side wall so that the distance from the Citation CBC 1115B.7.1.3 ADAAG 4.17.3
centerline of the toilet to the nearest side wall in the stall
designated to be accessible in the restroom is exactly 18 inches
(see ADAAG Figure 28. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1143
Maximum Estimated Cost: 1143
Record Number 422
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 442 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The seat cover dispenser in the stall designated to be
accessible in the restroom is mounted at a height greater than
40 inches and there is no clear floor space.

Alternative *
Rec:
(Where
Available)

Women's Restroom in the Maintenance Shop

Full Rec Relocate the seat cover dispenser in the stall designated to be Citation CBC 1115B.9.2
accessible in the restroom so that the height is no greater than
40 inches above the finished floor (see CBC 1115B.9.2). Make
certain that the location of the seat cover dispenser does not Minimum Quantity 1
interfere with the use of a grab bar and provides sufficient clear Maximum Quantity: 1
floor space.
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 423
Priority:

Restrooms
Finding: The faucet controls on the lavatory in the restroom require tight
grasping, pinching, or twisting of the wrist and are not
accessible.

Alternative *
Rec:
(Where
Available)

Women's Restroom in the Maintenance Shop

Full Rec Install faucet controls complying with ADAAG 4.19.5 on the Citation ADAAG 4.19.5
lavatory designated to be accessible in the restroom. Lever-
operated, push-type, touch-type or electronically controlled
mechanisms are acceptable elements (see ADAAG 4.19.5). If Minimum Quantity 1
self-closing valves are used the faucet shall remain open for at Maximum Quantity: 1
least 10 seconds.
Unit: Each
Minimum Estimated Cost: 392
Maximum Estimated Cost: 392
Record Number 424
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 443 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The knee clearance space under the lavatory designated to be
accessible in the restroom is less than 29 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom in the Maintenance Shop

Full Rec Raise or replace the lavatory designated to be accessible in the Citation ADAAG 4.19.2
restroom to provide at least 29 inches of clear knee space
between the finished floor and bottom of the lavatory apron.
Make sure to provide at least 27 inches at 8 inches under the Minimum Quantity 1
apron (see ADAAG 4.19.2). Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1286
Maximum Estimated Cost: 1286
Record Number 425
Priority:

Restrooms
Finding: The distance from the center of the lavatory to the adjacent side
wall in the restroom is less than 18 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom in the Maintenance Shop

Full Rec Relocate the lavatory to provide a centerline of at least 18 Citation ADAAG 4.19.3
inches. Make sure to provide at least 30 inches in width and 48
inch length of clear floor space to allow an accessible forward
approach (see ADAAG 4.19.3). Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 426
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 444 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The pipes under the lavatory in the restroom do not provide
protection against contact.

Alternative *
Rec:
(Where
Available)

Women's Restroom in the Maintenance Shop

Full Rec Insulate or otherwise configure pipes under the lavatory Citation ADAAG 4.19.4
designated to be accessible in the restroom to protect against
contact (see ADAAG 4.19.4). Make certain there are no sharp
or abrasive surfaces under the lavatory. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 39
Maximum Estimated Cost: 39
Record Number 427
Priority:

Restrooms
Finding: The bottom edge of the reflecting surface of the mirror in the
restroom is greater than 40 inches above the finished floor.

Alternative *
Rec:
(Where
Available)

Women's Restroom in the Maintenance Shop

Full Rec Lower the mirror in the restroom so that the bottom edge of the Citation ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG
reflecting surface is no higher than 40 inches above the finished 4.19.6
floor and the topmost portion of the reflecting surface extends at
least 74 inches above the finished floor (see ADAAG A4.19.6). Minimum Quantity 1
A single, full-length mirror is recommended since it can Maximum Quantity: 1
accommodate all people. Make certain to provide a minimum
clear floor space in front of the mirror of 30 inches in width and Unit: Each
48 inches in length. Minimum Estimated Cost: 291
Maximum Estimated Cost: 291
Record Number 428
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 445 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the controls and operating mechanisms for the
soap dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom in the Maintenance Shop

Full Rec Relocate the soap dispenser in the restroom to a maximum Citation CBC 1115B.9.2; ADAAG A4.27
height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 429
Priority:

Restrooms
Finding: The height of the controls and operating mechanisms for the
paper towel dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom in the Maintenance Shop

Full Rec Relocate the paper towel dispenser in the restroom to a Citation CBC 1115B.9.2; ADAAG A4.27
maximum height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 430
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 446 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: There is no accessible shower stall provided in the restroom.

Alternative *
Rec:
(Where
Available)

Women's Restroom in the Maintenance Shop

Full Rec Since a shower stall is provided in the restroom, at least one Citation CBC 1115B.6.2; ADAAG 4.21
accessible shower stall is required. Install an accessible shower
stall complying with CBC 1115B 6.2 and ADAAG 4.21 in the
restroom. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 2853
Maximum Estimated Cost: 2853
Record Number 441
Priority:

Restrooms
Finding: There is signage indicating accessibility on the entry door to the
restroom in the San Joaquin Room at the Winners Gaming and
Sports Emporium. The signage is centered 60 inches above
the floor on the latch side of the entrance door and includes
Braille and raised lettering, gender use symbol and the ISA
symbol.

Alternative *
Rec:
(Where
Available)

Women's Restroom in the San Joaquin Room

Full Rec The restroom is designated accessible and should be made an Citation CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7));
accessible restroom for the facility. Monitor signage for ADAAG 4.1.6(3)(e); ADAAG 4.30
continued compliance with CBC 1115B.5, ADAAG 4.1.2(7) and
ADAAG 4.1.6(3)(e)) and ADAAG 4.30. Minimum Quantity 1
Maximum Quantity: 1
Unit: None Selected
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 390
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 447 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: There are eight stalls located in the multiple accommodation
restroom.

Alternative *
Rec:
(Where
Available)

Women's Restroom in the San Joaquin Room

Full Rec Create an accessible 36-inch wide alternate stall in addition to Citation CBC 1115B.7.1.4; ADAAG A4.17.3; ADAAG
the required accessible standard stall in the multiple 4.22.4
accommodation restroom. The accessible 36-inch wide
alternate stall shall include an outward swinging, self-closing Minimum Quantity 1
door and parallel side grab bars and shall provide at least 66 Maximum Quantity: 1
inches in length for a stall with a wall-mounted toilet or at least
69 inches in length for a stall with a floor-mounted toilet. Unit: Each
Minimum Estimated Cost: 4000
Maximum Estimated Cost: 4000
Record Number 391
Priority:

Restrooms
Finding: There is insufficient clear floor space in the stall designated to
be accessible in the restroom. The door to the stall designated
to be accessible in the restroom does not close automatically or
have accessible hardware.

Alternative *
Rec:
(Where
Available)

Women's Restroom in the San Joaquin Room

Full Rec Modify or replace the stall designated to be accessible in the Citation CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
restroom so that it complies with ADAAG 4.17.3, CBC 1115B
and CBC Figures 11B-1A and 1B. Standard accessible stalls
require 60 inches in width with 56 inches depth for wall-mounted Minimum Quantity 1
toilets or 59 inches depth for floor-mounted toilets to Maximum Quantity: 1
accommodate individuals in wheelchairs. The minimum width of
a front-approach doorway shall provide at least 32 inches and a Unit: Each
side-approach doorway shall provide at least 34 inches. The Minimum Estimated Cost: 4000
door shall swing outward, close automatically and provide
accessible hardware. Maximum Estimated Cost: 4000
Record Number 392
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 448 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The location of the toilet paper dispenser in the stall designated
to be accessible in the restroom is not within 12 inches of the
front edge of the toilet seat.

Alternative *
Rec:
(Where
Available)

Women's Restroom in the San Joaquin Room

Full Rec Remount the toilet paper dispenser in the stall designated to be Citation CBC 1115B.9.3; ADAAG 4.16.6
accessible in the restroom so that it is within 12 inches from the
front edge of the toilet seat (see CBC 1115B.9.3 and ADAAG
Figure 29(b)). Toilet paper dispensers must allow continuous Minimum Quantity 1
paper flow and shall not interfere with the use of the side grab Maximum Quantity: 1
bar.
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 393
Priority:

Restrooms
Finding: The seat cover dispenser in the stall designated to be
accessible in the restroom is mounted at a height greater than
40 inches and there is no clear floor space.

Alternative *
Rec:
(Where
Available)

Women's Restroom in the San Joaquin Room

Full Rec Relocate the seat cover dispenser in the stall designated to be Citation CBC 1115B.9.2
accessible in the restroom so that the height is no greater than
40 inches above the finished floor (see CBC 1115B.9.2). Make
certain that the location of the seat cover dispenser does not Minimum Quantity 1
interfere with the use of a grab bar and provides sufficient clear Maximum Quantity: 1
floor space.
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 394
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 449 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The knee depth space under the lavatory designated to be
accessible in the restroom is less than 27 inches at 8 inches
under the lavatory apron.

Alternative *
Rec:
(Where
Available)

Women's Restroom in the San Joaquin Room

Full Rec Raise or replace the lavatory designated to be accessible in the Citation ADAAG 4.19.2
restroom to provide at least 27 inches at 8 inches under the
apron. Make sure to provide at least 29 inches of clear knee
space between the finished floor and bottom of the lavatory Minimum Quantity 1
apron and a rim surface height no greater than 34 inches (see Maximum Quantity: 1
ADAAG 4.19.2).
Unit: Each
Minimum Estimated Cost: 1286
Maximum Estimated Cost: 1286
Record Number 395
Priority:

Restrooms
Finding: The signage indicating accessibility on the latch side of the
entry door of the restroom is not centered at 60 inches above
the floor surface.

Alternative *
Rec:
(Where
Available)

Women's Restroom in the Winners Gaming and Sports


Emporium

Full Rec The restroom is designated accessible and should be made Citation CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7));
accessible for the facility. Post signage centered 60 inches ADAAG 4.1.6(3)(e); ADAAG 4.30
above the ground surface on the latch side of the entrance door
identifying the restroom as accessible upon completion of the Minimum Quantity 1
following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG Maximum Quantity: 1
4.1.6(3)(e). Signage shall include Braille and raised lettering,
the gender or unisex use symbol and the ISA symbol. Unit: Each
Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 396
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 450 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: There is insufficient clear floor space in the stall designated to
be accessible in the restroom. The door to the stall designated
to be accessible in the restroom does not have accessible
hardware.

Alternative *
Rec:
(Where
Available)

Women's Restroom in the Winners Gaming and Sports


Emporium

Full Rec Modify or replace the stall designated to be accessible in the Citation CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
restroom so that it complies with ADAAG 4.17.3, CBC 1115B
and CBC Figures 11B-1A and 1B. Standard accessible stalls
require 60 inches in width with 56 inches depth for wall-mounted Minimum Quantity 1
toilets or 59 inches depth for floor-mounted toilets to Maximum Quantity: 1
accommodate individuals in wheelchairs. The minimum width of
a front-approach doorway shall provide at least 32 inches and a Unit: Each
side-approach doorway shall provide at least 34 inches. The Minimum Estimated Cost: 4000
door shall swing outward, close automatically and provide
accessible hardware. Maximum Estimated Cost: 4000
Record Number 397
Priority:

Restrooms
Finding: The side grab bar in the stall designated to be accessible in the
restroom does not extend 54 inches from the back wall.

Alternative *
Rec:
(Where
Available)

Women's Restroom in the Winners Gaming and Sports


Emporium

Full Rec The front end of the grab bar shall extend at least 54 inches Citation CBC 1115B.8.1; ADAAG 4.26
from the back wall and the back end of the grab bar shall be
mounted within 12 inches from the back wall. Grab bars must
be able to support a point load of at least 250 pounds and shall Minimum Quantity 1
be less than the allowable shear stress of the grab bar material. Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 531
Maximum Estimated Cost: 531
Record Number 398
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 451 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The location of the toilet paper dispenser in the stall designated
to be accessible in the restroom is not within 12 inches of the
front edge of the toilet seat.

Alternative *
Rec:
(Where
Available)

Women's Restroom in the Winners Gaming and Sports


Emporium

Full Rec Remount the toilet paper dispenser in the stall designated to be Citation CBC 1115B.9.3; ADAAG 4.16.6
accessible in the restroom so that it is within 12 inches from the
front edge of the toilet seat (see CBC 1115B.9.3 and ADAAG
Figure 29(b)). Toilet paper dispensers must allow continuous Minimum Quantity 1
paper flow and shall not interfere with the use of the side grab Maximum Quantity: 1
bar.
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 399
Priority:

Restrooms
Finding: The distance from the center of the toilet to the nearest side
wall in the stall designated to be accessible in the restroom is
greater than 18 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom in the Winners Gaming and Sports


Emporium

Full Rec Relocate the toilet or stall side wall so that the distance from the Citation CBC 1115B.7.1.3 ADAAG 4.17.3
centerline of the toilet to the nearest side wall in the stall
designated to be accessible in the restroom is exactly 18 inches
(see ADAAG Figure 28. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1143
Maximum Estimated Cost: 1143
Record Number 400
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 452 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The seat cover dispenser in the stall designated to be
accessible in the restroom is mounted at a height greater than
40 inches and there is no clear floor space.

Alternative *
Rec:
(Where
Available)

Women's Restroom in the Winners Gaming and Sports


Emporium

Full Rec Relocate the seat cover dispenser in the stall designated to be Citation CBC 1115B.9.2
accessible in the restroom so that the height is no greater than
40 inches above the finished floor (see CBC 1115B.9.2). Make
certain that the location of the seat cover dispenser does not Minimum Quantity 1
interfere with the use of a grab bar and provides sufficient clear Maximum Quantity: 1
floor space.
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 401
Priority:

Restrooms
Finding: The height of the controls and operating mechanisms for the
soap dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom in the Winners Gaming and Sports


Emporium

Full Rec Relocate the soap dispenser in the restroom to a maximum Citation CBC 1115B.9.2; ADAAG A4.27
height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 402
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 453 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The signage indicating accessibility is not mounted on the latch
side of the entry door of the restroom. There is no Title 24
gender use signage on the entrance door.

Alternative *
Rec:
(Where
Available)

Women's Restroom Next to Horse Barn 4

Full Rec The restroom is designated accessible and should be made Citation CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7));
accessible for the facility. Post signage centered 60 inches ADAAG 4.1.6(3)(e); ADAAG 4.30
above the ground surface on the latch side of the entrance door
identifying the restroom as accessible upon completion of the Minimum Quantity 1
following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG Maximum Quantity: 1
4.1.6(3)(e). Signage shall include Braille and raised lettering,
the gender or unisex use symbol and the ISA symbol. Post Title Unit: Each
24 gender use signage on the door @ 60" o.c. a.f.f. Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 468
Priority:

Restrooms
Finding: There is insufficient clear floor space in the stall designated to
be accessible in the restroom. The stall door to the stall
designated to be accessible in the restroom swings inward
limiting the clear floor space in the stall designated to be
accessible. The door to the stall designated to be accessible in
the restroom does not close automatically or have accessible
hardware.

Alternative *
Rec:
(Where
Available)

Women's Restroom Next to Horse Barn 4

Full Rec Modify or replace the stall designated to be accessible in the Citation CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
restroom so that it complies with ADAAG 4.17.3, CBC 1115B
and CBC Figures 11B-1A and 1B. Standard accessible stalls
require 60 inches in width with 56 inches depth for wall-mounted Minimum Quantity 1
toilets or 59 inches depth for floor-mounted toilets to Maximum Quantity: 1
accommodate individuals in wheelchairs. The minimum width of
a front-approach doorway shall provide at least 32 inches and a Unit: Each
side-approach doorway shall provide at least 34 inches. The Minimum Estimated Cost: 4000
door shall swing outward, close automatically and provide
accessible hardware. Maximum Estimated Cost: 4000
Record Number 469
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 454 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the coat hook on the stall door designated to be
accessible in the restroom is greater than 48 inches above the
floor surface.

Alternative *
Rec:
(Where
Available)

Women's Restroom Next to Horse Barn 4

Full Rec Remount the coat hook on the stall door designated to be Citation CBC 1115B.9.2; ADAAG A4.27
accessible in the restroom to a maximum height of 48 inches
above the floor surface.
Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 470
Priority:

Restrooms
Finding: There are no grab bars in the stall designated to be accessible
in the restroom.

Alternative *
Rec:
(Where
Available)

Women's Restroom Next to Horse Barn 4

Full Rec Install one 36-inch back grab bar and one 42/48-inch side grab Citation CBC 1115B.8; ADAAG 4.26
bar in the stall designated to be accessible in the restroom.
Grab bars shall be mounted at a height of 33 inches above the
finished floor. Grab bars must be able to support a point load of Minimum Quantity 1
at least 250 pounds and shall be less than the allowable shear Maximum Quantity: 1
stress of the grab bar material.
Unit: Each
Minimum Estimated Cost: 531
Maximum Estimated Cost: 531
Record Number 471
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 455 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The flush control on the toilet in the stall designated to be
accessible in the restroom is not on the wide (approach) side of
the toilet.

Alternative *
Rec:
(Where
Available)

Women's Restroom Next to Horse Barn 4

Full Rec Relocate the flush control on the toilet in the stall designated to Citation ADAAG 4.16.5; ADAAG 4.27.4
be accessible in the restroom so that it is on the wide
(approach) side of the toilet area (see ADAAG 4.16.5). Flush
controls shall be hand-operated or automatic mechanisms. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 127
Maximum Estimated Cost: 127
Record Number 472
Priority:

Restrooms
Finding: The height of the toilet seat in the stall designated to be
accessible in the restroom is less than 17 inches above the
finished floor.

Alternative *
Rec:
(Where
Available)

Women's Restroom Next to Horse Barn 4

Full Rec Remove or modify the toilet in the stall designated to be Citation ADAAG 4.16.3
accessible in the restroom so that the seat height is between 17
inches and 19 inches above the finished floor (see ADAAG
4.16.3). Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1707
Maximum Estimated Cost: 1707
Record Number 473
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 456 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The distance from the center of the toilet to the nearest side
wall in the stall designated to be accessible in the restroom is
less than 18 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom Next to Horse Barn 4

Full Rec Relocate the toilet or stall side wall so that the distance from the Citation CBC 1115B.7.1.3 ADAAG 4.17.3
centerline of the toilet to the nearest side wall in the stall
designated to be accessible in the restroom is exactly 18 inches
(see ADAAG Figure 28. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1143
Maximum Estimated Cost: 1143
Record Number 474
Priority:

Restrooms
Finding: The seat cover dispenser in the stall designated to be
accessible in the restroom is mounted at a height greater than
40 inches and there is no clear floor space.

Alternative *
Rec:
(Where
Available)

Women's Restroom Next to Horse Barn 4

Full Rec Relocate the seat cover dispenser in the stall designated to be Citation CBC 1115B.9.2
accessible in the restroom so that the height is no greater than
40 inches above the finished floor (see CBC 1115B.9.2). Make
certain that the location of the seat cover dispenser does not Minimum Quantity 1
interfere with the use of a grab bar and provides sufficient clear Maximum Quantity: 1
floor space.
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 475
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 457 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The pipes under the lavatory in the restroom do not provide
protection against contact.

Alternative *
Rec:
(Where
Available)

Women's Restroom Next to Horse Barn 4

Full Rec Insulate or otherwise configure pipes under the lavatory Citation ADAAG 4.19.4
designated to be accessible in the restroom to protect against
contact (see ADAAG 4.19.4). Make certain there are no sharp
or abrasive surfaces under the lavatory. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 39
Maximum Estimated Cost: 39
Record Number 476
Priority:

Restrooms
Finding: The height of the controls and operating mechanisms for the
soap dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom Next to Horse Barn 4

Full Rec Relocate the soap dispenser in the restroom to a maximum Citation CBC 1115B.9.2; ADAAG A4.27
height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 477
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 458 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the controls and operating mechanisms for the
paper towel dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom Next to Horse Barn 4

Full Rec Relocate the paper towel dispenser in the restroom to a Citation CBC 1115B.9.2; ADAAG A4.27
maximum height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 478
Priority:

Restrooms
Finding: A showering facility is provided, though is not required. There is
no accessible shower stall provided in the restroom.

Alternative *
Rec:
(Where
Available)

Women's Restroom Next to Horse Barn 4

Full Rec Since a shower stall is provided in the restroom, at least one Citation CBC 1115B.6.2; ADAAG 4.21
accessible shower stall is required. Install an accessible shower
stall complying with CBC 1115B 6.2 and ADAAG 4.21 in the
restroom. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 2853
Maximum Estimated Cost: 2853
Record Number 479
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 459 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The signage indicating accessibility is not mounted on the latch
side of the entry door to the restroom. The gender use signage
on the entrance door is not mounted at 60 inches above the
floor surface.

Alternative *
Rec:
(Where
Available)

Women's Restroom Next to Horse Barn 5

Full Rec The restroom is designated accessible and should be made Citation CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7));
accessible for the facility. Post signage centered 60 inches ADAAG 4.1.6(3)(e); ADAAG 4.30
above the ground surface on the latch side of the entrance door
identifying the restroom as accessible upon completion of the Minimum Quantity 1
following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG Maximum Quantity: 1
4.1.6(3)(e). Signage shall include Braille and raised lettering,
the gender or unisex use symbol and the ISA symbol. Post Title Unit: Each
24 gender use signage on the door @ 60" o.c. a.f.f. Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 455
Priority:

Restrooms
Finding: There is insufficient clear floor space in the stall designated to
be accessible in the restroom. The stall door to the stall
designated to be accessible in the restroom swings inward
limiting the clear floor space in the stall designated to be
accessible. The door to the stall designated to be accessible in
the restroom does not close automatically or have accessible
hardware.

Alternative *
Rec:
(Where
Available)

Women's Restroom Next to Horse Barn 5

Full Rec Modify or replace the stall designated to be accessible in the Citation CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
restroom so that it complies with ADAAG 4.17.3, CBC 1115B
and CBC Figures 11B-1A and 1B. Standard accessible stalls
require 60 inches in width with 56 inches depth for wall-mounted Minimum Quantity 1
toilets or 59 inches depth for floor-mounted toilets to Maximum Quantity: 1
accommodate individuals in wheelchairs. The minimum width of
a front-approach doorway shall provide at least 32 inches and a Unit: Each
side-approach doorway shall provide at least 34 inches. The Minimum Estimated Cost: 4000
door shall swing outward, close automatically and provide
accessible hardware. Maximum Estimated Cost: 4000
Record Number 456
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 460 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the coat hook on the stall door designated to be
accessible in the restroom is greater than 48 inches above the
floor surface.

Alternative *
Rec:
(Where
Available)

Women's Restroom Next to Horse Barn 5

Full Rec Remount the coat hook on the stall door designated to be Citation CBC 1115B.9.2; ADAAG A4.27
accessible in the restroom to a maximum height of 48 inches
above the floor surface.
Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 457
Priority:

Restrooms
Finding: There are no grab bars in the stall designated to be accessible
in the restroom.

Alternative *
Rec:
(Where
Available)

Women's Restroom Next to Horse Barn 5

Full Rec Install one 36-inch back grab bar and one 42/48-inch side grab Citation CBC 1115B.8; ADAAG 4.26
bar in the stall designated to be accessible in the restroom.
Grab bars shall be mounted at a height of 33 inches above the
finished floor. Grab bars must be able to support a point load of Minimum Quantity 1
at least 250 pounds and shall be less than the allowable shear Maximum Quantity: 1
stress of the grab bar material.
Unit: Each
Minimum Estimated Cost: 531
Maximum Estimated Cost: 531
Record Number 458
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 461 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the toilet seat in the stall designated to be
accessible in the restroom is less than 17 inches above the
finished floor.

Alternative *
Rec:
(Where
Available)

Women's Restroom Next to Horse Barn 5

Full Rec Remove or modify the toilet in the stall designated to be Citation ADAAG 4.16.3
accessible in the restroom so that the seat height is between 17
inches and 19 inches above the finished floor (see ADAAG
4.16.3). Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1707
Maximum Estimated Cost: 1707
Record Number 459
Priority:

Restrooms
Finding: The distance from the center of the toilet to the nearest side
wall in the stall designated to be accessible in the restroom is
less than 18 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom Next to Horse Barn 5

Full Rec Relocate the toilet or stall side wall so that the distance from the Citation CBC 1115B.7.1.3 ADAAG 4.17.3
centerline of the toilet to the nearest side wall in the stall
designated to be accessible in the restroom is exactly 18 inches
(see ADAAG Figure 28. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1143
Maximum Estimated Cost: 1143
Record Number 460
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 462 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The seat cover dispenser in the stall designated to be
accessible in the restroom is mounted at a height greater than
40 inches and there is no clear floor space.

Alternative *
Rec:
(Where
Available)

Women's Restroom Next to Horse Barn 5

Full Rec Relocate the seat cover dispenser in the stall designated to be Citation CBC 1115B.9.2
accessible in the restroom so that the height is no greater than
40 inches above the finished floor (see CBC 1115B.9.2). Make
certain that the location of the seat cover dispenser does not Minimum Quantity 1
interfere with the use of a grab bar and provides sufficient clear Maximum Quantity: 1
floor space.
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 461
Priority:

Restrooms
Finding: The pipes under the lavatory in the restroom do not provide
protection against contact.

Alternative *
Rec:
(Where
Available)

Women's Restroom Next to Horse Barn 5

Full Rec Insulate or otherwise configure pipes under the lavatory Citation ADAAG 4.19.4
designated to be accessible in the restroom to protect against
contact (see ADAAG 4.19.4). Make certain there are no sharp
or abrasive surfaces under the lavatory. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 39
Maximum Estimated Cost: 39
Record Number 462
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 463 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The bottom edge of the reflecting surface of the mirror in the
restroom is greater than 40 inches above the finished floor.

Alternative *
Rec:
(Where
Available)

Women's Restroom Next to Horse Barn 5

Full Rec Lower the mirror in the restroom so that the bottom edge of the Citation ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG
reflecting surface is no higher than 40 inches above the finished 4.19.6
floor and the topmost portion of the reflecting surface extends at
least 74 inches above the finished floor (see ADAAG A4.19.6). Minimum Quantity 1
A single, full-length mirror is recommended since it can Maximum Quantity: 1
accommodate all people. Make certain to provide a minimum
clear floor space in front of the mirror of 30 inches in width and Unit: Each
48 inches in length. Minimum Estimated Cost: 291
Maximum Estimated Cost: 291
Record Number 463
Priority:

Restrooms
Finding: The height of the controls and operating mechanisms for the
soap dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom Next to Horse Barn 5

Full Rec Relocate the soap dispenser in the restroom to a maximum Citation CBC 1115B.9.2; ADAAG A4.27
height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 464
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 464 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the controls and operating mechanisms for the
paper towel dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom Next to Horse Barn 5

Full Rec Relocate the paper towel dispenser in the restroom to a Citation CBC 1115B.9.2; ADAAG A4.27
maximum height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 465
Priority:

Restrooms
Finding: Showering facilities are provided, though are not required.
There are no accessible shower stalls provided in the restroom.

Alternative *
Rec:
(Where
Available)

Women's Restroom Next to Horse Barn 5

Full Rec Since shower stalls are provided in the restroom, at least one Citation CBC 1115B.6.2; ADAAG 4.21
accessible shower stall is required. Install an accessible shower
stall complying with CBC 1115B 6.2 and ADAAG 4.21 in the
restroom. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 2853
Maximum Estimated Cost: 2853
Record Number 466
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 465 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The signage on the latch side of the entry door of the restroom
does not include the International Symbol of Accessibility. The
gender use signage is not mounted on the entrance door and
does not include Braille or raised lettering.

Alternative *
Rec:
(Where
Available)

Women's Restroom Next to Horse Barn G

Full Rec The restroom is designated accessible and should be made Citation CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7));
accessible for the facility. Post signage centered 60 inches ADAAG 4.1.6(3)(e); ADAAG 4.30
above the ground surface on the latch side of the entrance door
identifying the restroom as accessible upon completion of the Minimum Quantity 1
following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG Maximum Quantity: 1
4.1.6(3)(e). Signage shall include Braille and raised lettering,
the gender or unisex use symbol and the ISA symbol. Post Title Unit: Each
24 gender use signage on the door @ 60" o.c. a.f.f. Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 918
Priority:

Restrooms
Finding: There is insufficient clear floor space in the stall designated to
be accessible in the restroom. The stall door to the stall
designated to be accessible in the restroom swings inward
limiting the clear floor space in the stall designated to be
accessible. The door to the stall designated to be accessible in
the restroom does not close automatically or have accessible
hardware.

Alternative *
Rec:
(Where
Available)

Women's Restroom Next to Horse Barn G

Full Rec Modify or replace the stall designated to be accessible in the Citation CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
restroom so that it complies with ADAAG 4.17.3, CBC 1115B
and CBC Figures 11B-1A and 1B. Standard accessible stalls
require 60 inches in width with 56 inches depth for wall-mounted Minimum Quantity 1
toilets or 59 inches depth for floor-mounted toilets to Maximum Quantity: 1
accommodate individuals in wheelchairs. The minimum width of
a front-approach doorway shall provide at least 32 inches and a Unit: Each
side-approach doorway shall provide at least 34 inches. The Minimum Estimated Cost: 4000
door shall swing outward, close automatically and provide
accessible hardware. Maximum Estimated Cost: 4000
Record Number 919
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 466 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the coat hook on the stall door designated to be
accessible in the restroom is greater than 48 inches above the
floor surface.

Alternative *
Rec:
(Where
Available)

Women's Restroom Next to Horse Barn G

Full Rec Remount the coat hook on the stall door designated to be Citation CBC 1115B.9.2; ADAAG A4.27
accessible in the restroom to a maximum height of 48 inches
above the floor surface.
Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 920
Priority:

Restrooms
Finding: There are no grab bars in the stall designated to be accessible
in the restroom.

Alternative *
Rec:
(Where
Available)

Women's Restroom Next to Horse Barn G

Full Rec Install one 36-inch back grab bar and one 42/48-inch side grab Citation CBC 1115B.8; ADAAG 4.26
bar in the stall designated to be accessible in the restroom.
Grab bars shall be mounted at a height of 33 inches above the
finished floor. Grab bars must be able to support a point load of Minimum Quantity 1
at least 250 pounds and shall be less than the allowable shear Maximum Quantity: 1
stress of the grab bar material.
Unit: Each
Minimum Estimated Cost: 531
Maximum Estimated Cost: 531
Record Number 921
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 467 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the toilet seat in the stall designated to be
accessible in the restroom is less than 17 inches above the
finished floor.

Alternative *
Rec:
(Where
Available)

Women's Restroom Next to Horse Barn G

Full Rec Remove or modify the toilet in the stall designated to be Citation ADAAG 4.16.3
accessible in the restroom so that the seat height is between 17
inches and 19 inches above the finished floor (see ADAAG
4.16.3). Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1707
Maximum Estimated Cost: 1707
Record Number 923
Priority:

Restrooms
Finding: The distance from the center of the toilet to the nearest side
wall in the stall designated to be accessible in the restroom is
less than 18 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom Next to Horse Barn G

Full Rec Relocate the toilet or stall side wall so that the distance from the Citation CBC 1115B.7.1.3 ADAAG 4.17.3
centerline of the toilet to the nearest side wall in the stall
designated to be accessible in the restroom is exactly 18 inches
(see ADAAG Figure 28. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1143
Maximum Estimated Cost: 1143
Record Number 924
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 468 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The seat cover dispenser in the stall designated to be
accessible in the restroom is mounted at a height greater than
40 inches and there is no clear floor space.

Alternative *
Rec:
(Where
Available)

Women's Restroom Next to Horse Barn G

Full Rec Relocate the seat cover dispenser in the stall designated to be Citation CBC 1115B.9.2
accessible in the restroom so that the height is no greater than
40 inches above the finished floor (see CBC 1115B.9.2). Make
certain that the location of the seat cover dispenser does not Minimum Quantity 1
interfere with the use of a grab bar and provides sufficient clear Maximum Quantity: 1
floor space.
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 925
Priority:

Restrooms
Finding: The knee depth space under the lavatory designated to be
accessible in the restroom is less than 27 inches at 8 inches
under the lavatory apron.

Alternative *
Rec:
(Where
Available)

Women's Restroom Next to Horse Barn G

Full Rec Raise or replace the lavatory designated to be accessible in the Citation ADAAG 4.19.2
restroom to provide at least 27 inches at 8 inches under the
apron. Make sure to provide at least 29 inches of clear knee
space between the finished floor and bottom of the lavatory Minimum Quantity 1
apron and a rim surface height no greater than 34 inches (see Maximum Quantity: 1
ADAAG 4.19.2).
Unit: Each
Minimum Estimated Cost: 1286
Maximum Estimated Cost: 1286
Record Number 926
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 469 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The pipes under the lavatory in the restroom do not provide
protection against contact.

Alternative *
Rec:
(Where
Available)

Women's Restroom Next to Horse Barn G

Full Rec Insulate or otherwise configure pipes under the lavatory Citation ADAAG 4.19.4
designated to be accessible in the restroom to protect against
contact (see ADAAG 4.19.4). Make certain there are no sharp
or abrasive surfaces under the lavatory. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 39
Maximum Estimated Cost: 39
Record Number 927
Priority:

Restrooms
Finding: The bottom edge of the reflecting surface of the mirror in the
restroom is greater than 40 inches above the finished floor.

Alternative *
Rec:
(Where
Available)

Women's Restroom Next to Horse Barn G

Full Rec Lower the mirror in the restroom so that the bottom edge of the Citation ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG
reflecting surface is no higher than 40 inches above the finished 4.19.6
floor and the topmost portion of the reflecting surface extends at
least 74 inches above the finished floor (see ADAAG A4.19.6). Minimum Quantity 1
A single, full-length mirror is recommended since it can Maximum Quantity: 1
accommodate all people. Make certain to provide a minimum
clear floor space in front of the mirror of 30 inches in width and Unit: Each
48 inches in length. Minimum Estimated Cost: 291
Maximum Estimated Cost: 291
Record Number 928
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 470 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the controls and operating mechanisms for the
soap dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom Next to Horse Barn G

Full Rec Relocate the soap dispenser in the restroom to a maximum Citation CBC 1115B.9.2; ADAAG A4.27
height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 929
Priority:

Restrooms
Finding: The height of the controls and operating mechanisms for the
paper towel dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom Next to Horse Barn G

Full Rec Relocate the paper towel dispenser in the restroom to a Citation CBC 1115B.9.2; ADAAG A4.27
maximum height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 930
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 471 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The women's restroom provides two private shower stalls.
There are no accessible shower stalls provided in the restroom.

Alternative *
Rec:
(Where
Available)

Women's Restroom Next to Horse Barn G

Full Rec Since shower stalls are provided in the restroom, at least one Citation CBC 1115B.6.2; ADAAG 4.21
accessible shower stall is required. Install an accessible shower
stall complying with CBC 1115B 6.2 and ADAAG 4.21 in the
women's restroom. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 2853
Maximum Estimated Cost: 2853
Record Number 931
Priority:

Restrooms
Finding: The clear opening width of the entrance to the showers in the
restroom is less than 32 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom Next to Horse Barn G

Full Rec Widen the entrance doorway to the showers in the restroom to Citation ADAAG 4.13.5
provide a clear opening width of at least 32 inches when the
door is open 90 degrees (see ADAAG 4.13.5).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 750
Maximum Estimated Cost: 750
Record Number 932
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 472 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: There is less than 18 inches on the latch side of the entrance
door to the showers in the restroom from the pull side.

Alternative *
Rec:
(Where
Available)

Women's Restroom Next to Horse Barn G

Full Rec Consult a design professional to determine if it is technically Citation ADAAG 4.13.6; CBC 1133B.2.4.2
feasible to provide at least 18 inches of latch side clearance at
the entrance door to the restroom from the pull side (see
ADAAG 4.13.6 and Figure 25). Otherwise, an automatic door Minimum Quantity 1
opening device may be required to provide an accessible Maximum Quantity: 1
entrance.
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 933
Priority:

Restrooms
Finding: The latch side approach to the shower stall designated to be
accessible in the restroom is less than 44 inches wide.

Alternative *
Rec:
(Where
Available)

Women's Restroom Next to Horse Barn G

Full Rec Consult a design professional to provide a latch-side approach Citation CBC 1115B.7.1.3; ADAAG 4.17.3
to the shower stall designated to be accessible with a clear,
unobstructed access width of 44 inches with the space
immediately in front of the stall door at 48 inches in width. All Minimum Quantity 1
other approaches require 48 inches of clear, unobstructed Maximum Quantity: 1
access to and in front of the stall designated to be accessible in
the restroom. Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 934
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 473 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: There is no signage indicating accessibility on the latch side of
the entry door of the restroom. The gender use signage is not
mounted on the entrance door and is not centered at 60 inches
above the floor surface.

Alternative *
Rec:
(Where
Available)

Women's Restroom Next to L-2 and L-3

Full Rec The restroom is designated accessible and should be made Citation CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7));
accessible for the facility. Post signage centered 60 inches ADAAG 4.1.6(3)(e); ADAAG 4.30
above the ground surface on the latch side of the entrance door
identifying the restroom as accessible upon completion of the Minimum Quantity 1
following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG Maximum Quantity: 1
4.1.6(3)(e). Signage shall include Braille and raised lettering,
the gender or unisex use symbol and the ISA symbol. Post Title Unit: Each
24 gender use signage on the door @ 60" o.c. a.f.f. Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 814
Priority:

Restrooms
Finding: The clear opening width of the entrance doorway to the
restroom is less than 32 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom Next to L-2 and L-3

Full Rec Widen the entrance doorway to the restroom to provide a clear Citation ADAAG 4.13.5
opening width of at least 32 inches when the door is open 90
degrees (see ADAAG 4.13.5).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 750
Maximum Estimated Cost: 750
Record Number 815
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 474 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The entrance door to the restroom has a round doorknob that
requires tight grasping or twisting of the wrist to operate.

Alternative *
Rec:
(Where
Available)

Women's Restroom Next to L-2 and L-3

Full Rec Replace the door hardware mounted on the restroom complying Citation ADAAG 4.13.9
with ADAAG 4.13.9. Make certain accessible door hardware is
mounted no higher than 48 inches above the finished floor.
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 204
Maximum Estimated Cost: 204
Record Number 816
Priority:

Restrooms
Finding: There are seven stalls located in the multiple accommodation
restroom.

Alternative *
Rec:
(Where
Available)

Women's Restroom Next to L-2 and L-3

Full Rec Create an accessible 36-inch wide alternate stall in addition to Citation CBC 1115B.7.1.4; ADAAG A4.17.3; ADAAG
the required accessible standard stall in the multiple 4.22.4
accommodation restroom. The accessible 36-inch wide
alternate stall shall include an outward swinging, self-closing Minimum Quantity 1
door and parallel side grab bars and shall provide at least 66 Maximum Quantity: 1
inches in length for a stall with a wall-mounted toilet or at least
69 inches in length for a stall with a floor-mounted toilet. Unit: Each
Minimum Estimated Cost: 4000
Maximum Estimated Cost: 4000
Record Number 817
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 475 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: There is insufficient clear floor space in the stall designated to
be accessible in the restroom. The door to the stall designated
to be accessible in the restroom does not close automatically or
have accessible hardware.

Alternative *
Rec:
(Where
Available)

Women's Restroom Next to L-2 and L-3

Full Rec Modify or replace the stall designated to be accessible in the Citation CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
restroom so that it complies with ADAAG 4.17.3, CBC 1115B
and CBC Figures 11B-1A and 1B. Standard accessible stalls
require 60 inches in width with 56 inches depth for wall-mounted Minimum Quantity 1
toilets or 59 inches depth for floor-mounted toilets to Maximum Quantity: 1
accommodate individuals in wheelchairs. The minimum width of
a front-approach doorway shall provide at least 32 inches and a Unit: Each
side-approach doorway shall provide at least 34 inches. The Minimum Estimated Cost: 4000
door shall swing outward, close automatically and provide
accessible hardware. Maximum Estimated Cost: 4000
Record Number 818
Priority:

Restrooms
Finding: There is no back grab bar in the stall designated to be
accessible in the restroom.

Alternative *
Rec:
(Where
Available)

Women's Restroom Next to L-2 and L-3

Full Rec Install a 36-inch back grab bar at a height of 33 inches above Citation CBC 1115B.8.1; ADAAG 4.26
the finished floor in the stall designated to be accessible of the
restroom. Grab bars must be able to support a point load of at
least 250 pounds and shall be less than the allowable shear Minimum Quantity 1
stress of the grab bar material. Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 531
Maximum Estimated Cost: 531
Record Number 819
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 476 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the left grab bar in the stall designated to be
accessible of the restroom is greater than 33 inches above the
finished floor.

Alternative *
Rec:
(Where
Available)

Women's Restroom Next to L-2 and L-3

Full Rec Remount the left grab bar in the stall designated to be Citation CBC 1115B.8.1; ADAAG 4.26
accessible in the restroom so that the height of the gripping
surface is centered at 33 inches above finished floor. Grab bars
must be able to support a point load of at least 250 pounds and Minimum Quantity 1
shall be less than the allowable shear stress of the grab bar Maximum Quantity: 1
material.
Unit: Each
Minimum Estimated Cost: 448
Maximum Estimated Cost: 448
Record Number 820
Priority:

Restrooms
Finding: The side grab bars in the stall designated to be accessible in
the restroom do not extend 54 inches from the back wall.

Alternative *
Rec:
(Where
Available)

Women's Restroom Next to L-2 and L-3

Full Rec The front end of the grab bars shall extend at least 54 inches Citation CBC 1115B.8.1; ADAAG 4.26
from the back wall and the back end of the grab bar shall be
mounted within 12 inches from the back wall. Grab bars must
be able to support a point load of at least 250 pounds and shall Minimum Quantity 1
be less than the allowable shear stress of the grab bar material. Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 531
Maximum Estimated Cost: 531
Record Number 821
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 477 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The location of the toilet paper dispenser in the stall designated
to be accessible in the restroom is not within 12 inches of the
front edge of the toilet seat.

Alternative *
Rec:
(Where
Available)

Women's Restroom Next to L-2 and L-3

Full Rec Remount the toilet paper dispenser in the stall designated to be Citation CBC 1115B.9.3; ADAAG 4.16.6
accessible in the restroom so that it is within 12 inches from the
front edge of the toilet seat and does not encroach more than
four inches from the face of the wall (see CBC 1115B.9.3 and Minimum Quantity 1
ADAAG Figure 29(b)). Toilet paper dispensers must allow Maximum Quantity: 1
continuous paper flow and shall not interfere with the use of the
side grab bar. Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 822
Priority:

Restrooms
Finding: The height of the toilet seat in the stall designated to be
accessible in the restroom is less than 17 inches above the
finished floor.

Alternative *
Rec:
(Where
Available)

Women's Restroom Next to L-2 and L-3

Full Rec Remove or modify the toilet in the stall designated to be Citation ADAAG 4.16.3
accessible in the restroom so that the seat height is between 17
inches and 19 inches above the finished floor (see ADAAG
4.16.3). Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1707
Maximum Estimated Cost: 1707
Record Number 823
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 478 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The distance from the center of the toilet to the nearest side
wall in the stall designated to be accessible in the restroom is
greater than 18 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom Next to L-2 and L-3

Full Rec Relocate the toilet or stall side wall so that the distance from the Citation CBC 1115B.7.1.3 ADAAG 4.17.3
centerline of the toilet to the nearest side wall in the stall
designated to be accessible in the restroom is exactly 18 inches
(see ADAAG Figure 28. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1143
Maximum Estimated Cost: 1143
Record Number 824
Priority:

Restrooms
Finding: The seat cover dispenser in the stall designated to be
accessible in the restroom is mounted at a height greater than
40 inches and there is no clear floor space.

Alternative *
Rec:
(Where
Available)

Women's Restroom Next to L-2 and L-3

Full Rec Relocate the seat cover dispenser in the stall designated to be Citation CBC 1115B.9.2
accessible in the restroom so that the height is no greater than
40 inches above the finished floor (see CBC 1115B.9.2). Make
certain that the location of the seat cover dispenser does not Minimum Quantity 1
interfere with the use of a grab bar and provides sufficient clear Maximum Quantity: 1
floor space.
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 825
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 479 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The knee clearance space under the lavatory designated to be
accessible in the restroom is less than 29 inches. The knee
depth space under the lavatory designated to be accessible in
the restroom is less than 27 inches at 8 inches under the
lavatory apron.

Alternative *
Rec:
(Where
Available)

Women's Restroom Next to L-2 and L-3

Full Rec Replace the lavatory designated to be accessible in the Citation ADAAG 4.19.2
restroom to provide at least 29 inches of clear knee space
between the finished floor and bottom of the lavatory apron.
Make sure to provide at least 27 inches at 8 inches under the Minimum Quantity 1
apron (see ADAAG 4.19.2). Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1286
Maximum Estimated Cost: 1286
Record Number 826
Priority:

Restrooms
Finding: The pipes under the lavatory in the restroom do not provide
protection against contact.

Alternative *
Rec:
(Where
Available)

Women's Restroom Next to L-2 and L-3

Full Rec Insulate or otherwise configure pipes under the lavatory Citation ADAAG 4.19.4
designated to be accessible in the restroom to protect against
contact (see ADAAG 4.19.4). Make certain there are no sharp
or abrasive surfaces under the lavatory. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 39
Maximum Estimated Cost: 39
Record Number 827
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 480 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The bottom edge of the reflecting surface of the mirror in the
restroom is greater than 40 inches above the finished floor.

Alternative *
Rec:
(Where
Available)

Women's Restroom Next to L-2 and L-3

Full Rec Lower the mirror in the restroom so that the bottom edge of the Citation ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG
reflecting surface is no higher than 40 inches above the finished 4.19.6
floor and the topmost portion of the reflecting surface extends at
least 74 inches above the finished floor (see ADAAG A4.19.6). Minimum Quantity 1
A single, full-length mirror is recommended since it can Maximum Quantity: 1
accommodate all people. Make certain to provide a minimum
clear floor space in front of the mirror of 30 inches in width and Unit: Each
48 inches in length. Minimum Estimated Cost: 291
Maximum Estimated Cost: 291
Record Number 828
Priority:

Restrooms
Finding: The signage indicating accessibility on the latch side of the
entry door of the restroom is not centered at 60 inches above
the floor surface. There is no Title 24 gender use signage on
the entrance door.

Alternative *
Rec:
(Where
Available)

Women's Restroom on the Second Floor of the


Grandstands

Full Rec The restroom is designated accessible and should be made Citation CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7));
accessible for the facility. Post signage centered 60 inches ADAAG 4.1.6(3)(e); ADAAG 4.30
above the ground surface on the latch side of the entrance door
identifying the restroom as accessible upon completion of the Minimum Quantity 1
following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG Maximum Quantity: 1
4.1.6(3)(e). Signage shall include Braille and raised lettering,
the gender or unisex use symbol and the ISA symbol. Post Title Unit: Each
24 gender use signage on the door @ 60" o.c. a.f.f. Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 598
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 481 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The door to the stall designated to be accessible in the
restroom does not close automatically.

Alternative *
Rec:
(Where
Available)

Women's Restroom on the Second Floor of the


Grandstands

Full Rec Provide an automatic door closer, spring hinge, pull bar or Citation ADAAG A4.17.5
accessible handle mounted on the inside of the stall door to the
stall designated to be accessible in the restroom (see ADAAG
A4.17.5). Accessible hardware on the inside and outside of the Minimum Quantity 1
stall designated to be accessible door shall be equipped with a Maximum Quantity: 1
loop or U-shaped handle mounted immediately below the latch.
The latch shall be flip-over style, sliding or other hardware not Unit: Each
requiring grasping or twisting. Make certain that the inside and Minimum Estimated Cost: 269
outside door hardware is mounted no more than 48 inches
above the finished floor (see CBC 115B.7.1.3 and ADAAG Maximum Estimated Cost: 269
4.13.9). Record Number 599
Priority:

Restrooms
Finding: The height of the coat hook on the standard stall door
designated to be accessible in the restroom is greater than 48
inches above the floor surface.

Alternative *
Rec:
(Where
Available)

Women's Restroom on the Second Floor of the


Grandstands

Full Rec Remount the coat hook on the stall door designated to be Citation CBC 1115B.9.2; ADAAG A4.27
accessible in the restroom to a maximum height of 48 inches
above the floor surface.
Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 600
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 482 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the side grab bar in the standard stall designated
to be accessible of the restroom is greater than 33 inches above
the finished floor.

Alternative *
Rec:
(Where
Available)

Women's Restroom on the Second Floor of the


Grandstands

Full Rec Remount the side grab bar in the stall designated to be Citation CBC 1115B.8.1; ADAAG 4.26
accessible in the restroom so that the height of the gripping
surface is centered at 33 inches above finished floor. Grab bars
must be able to support a point load of at least 250 pounds and Minimum Quantity 1
shall be less than the allowable shear stress of the grab bar Maximum Quantity: 1
material.
Unit: Each
Minimum Estimated Cost: 448
Maximum Estimated Cost: 448
Record Number 601
Priority:

Restrooms
Finding: The side grab bar in the standard stall designated to be
accessible in the restroom does not extend 54 inches from the
back wall.

Alternative *
Rec:
(Where
Available)

Women's Restroom on the Second Floor of the


Grandstands

Full Rec The front end of the grab bar shall extend at least 54 inches Citation CBC 1115B.8.1; ADAAG 4.26
from the back wall and the back end of the grab bar shall be
mounted within 12 inches from the back wall. Grab bars must
be able to support a point load of at least 250 pounds and shall Minimum Quantity 1
be less than the allowable shear stress of the grab bar material. Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 531
Maximum Estimated Cost: 531
Record Number 602
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 483 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The location of the toilet paper dispenser in the standard stall
and the alternate stall designated to be accessible in the
restroom is not within 12 inches of the front edge of the toilet
seat.

Alternative *
Rec:
(Where
Available)

Women's Restroom on the Second Floor of the


Grandstands

Full Rec Remount the toilet paper dispenser in the stall designated to be Citation CBC 1115B.9.3; ADAAG 4.16.6
accessible in the restroom so that it is within 12 inches from the
front edge of the toilet seat (see CBC 1115B.9.3 and ADAAG
Figure 29(b)). Toilet paper dispensers must allow continuous Minimum Quantity 1
paper flow and shall not interfere with the use of the side grab Maximum Quantity: 1
bar.
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 603
Priority:

Restrooms
Finding: The flush control on the toilet in the alternate stall designated to
be accessible in the restroom is not on the wide (approach) side
of the toilet.

Alternative *
Rec:
(Where
Available)

Women's Restroom on the Second Floor of the


Grandstands

Full Rec Relocate the flush control on the toilet in the stall designated to Citation ADAAG 4.16.5; ADAAG 4.27.4
be accessible in the restroom so that it is on the wide
(approach) side of the toilet area (see ADAAG 4.16.5). Flush
controls shall be hand-operated or automatic mechanisms. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 127
Maximum Estimated Cost: 127
Record Number 604
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 484 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The distance from the center of the toilet to the nearest side
wall in the standard stall and the alternate stall designated to be
accessible in the restroom is less than 18 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom on the Second Floor of the


Grandstands

Full Rec Relocate the toilet or stall side wall so that the distance from the Citation CBC 1115B.7.1.3 ADAAG 4.17.3
centerline of the toilet to the nearest side wall in the stall
designated to be accessible in the restroom is exactly 18 inches
(see ADAAG Figure 28. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1143
Maximum Estimated Cost: 1143
Record Number 605
Priority:

Restrooms
Finding: The seat cover dispenser in the standard stall designated to be
accessible in the restroom is mounted at a height greater than
40 inches and there is no clear floor space.

Alternative *
Rec:
(Where
Available)

Women's Restroom on the Second Floor of the


Grandstands

Full Rec Relocate the seat cover dispenser in the stall designated to be Citation CBC 1115B.9.2
accessible in the restroom so that the height is no greater than
40 inches above the finished floor (see CBC 1115B.9.2). Make
certain that the location of the seat cover dispenser does not Minimum Quantity 1
interfere with the use of a grab bar and provides sufficient clear Maximum Quantity: 1
floor space.
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 606
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 485 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the controls and operating mechanisms for the
soap dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom on the Second Floor of the


Grandstands

Full Rec Relocate the soap dispenser in the restroom to a maximum Citation CBC 1115B.9.2; ADAAG A4.27
height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 607
Priority:

Restrooms
Finding: The height of the controls and operating mechanisms for the
paper towel dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom on the Second Floor of the


Grandstands

Full Rec Relocate the paper towel dispenser in the restroom to a Citation CBC 1115B.9.2; ADAAG A4.27
maximum height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 608
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 486 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The signage on the latch side of the entry door of the restroom
does not include the International Symbol of Accessibility. The
gender use signage is not mounted outside of the entrance door.

Alternative *
Rec:
(Where
Available)

Women's Restroom Outside of Building 3

Full Rec The restroom is designated accessible and should be made Citation CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7));
accessible for the facility. Post signage centered 60 inches ADAAG 4.1.6(3)(e); ADAAG 4.30
above the ground surface on the latch side of the entrance door
identifying the restroom as accessible upon completion of the Minimum Quantity 1
following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG Maximum Quantity: 1
4.1.6(3)(e). Signage shall include Braille and raised lettering,
the gender or unisex use symbol and the ISA symbol. Post Title Unit: Each
24 gender use signage on the door @ 60" o.c. a.f.f. Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 1015
Priority:

Restrooms
Finding: The bottom 10 inches of the door does not provide a smooth,
uninterrupted surface, or panel to allow the door to be opened
by a wheelchair footrest without creating a trap or hazardous
condition, due to the doorstop.

Alternative *
Rec:
(Where
Available)

Women's Restroom Outside of Building 3

Full Rec Install a panel or replace the door to provide a smooth, Citation CBC 1133B.2.6
uninterrupted surface for the bottom 10 inches of the door.

Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 1016
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 487 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: There is insufficient clear floor space in the standard stall
designated to be accessible in the restroom.

Alternative *
Rec:
(Where
Available)

Women's Restroom Outside of Building 3

Full Rec Modify or replace the standard stall designated to be accessible Citation CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
in the restroom so that it complies with ADAAG 4.17.3, CBC
1115B and CBC Figures 11B-1A and 1B. Standard accessible
stalls require 60 inches in width with 56 inches depth for wall- Minimum Quantity 1
mounted toilets or 59 inches depth for floor-mounted toilets to Maximum Quantity: 1
accommodate individuals in wheelchairs. The minimum width of
a front-approach doorway shall provide at least 32 inches and a Unit: Each
side-approach doorway shall provide at least 34 inches. The Minimum Estimated Cost: 4000
door shall swing outward, close automatically and provide
accessible hardware. Maximum Estimated Cost: 4000
Record Number 1017
Priority:

Restrooms
Finding: The door to the alternate stall designated to be accessible in the
restroom does not close automatically or have accessible
hardware. The inside handle on the standard stall door is not
mounted immediately below the latch.

Alternative *
Rec:
(Where
Available)

Women's Restroom Outside of Building 3

Full Rec Provide an automatic door closer, spring hinge, pull bar or Citation ADAAG A4.17.5
accessible handle mounted on the inside of the stall door to the
stall designated to be accessible in the restroom (see ADAAG
A4.17.5). Accessible hardware on the inside and outside of the Minimum Quantity 1
stall designated to be accessible door shall be equipped with a Maximum Quantity: 1
loop or U-shaped handle mounted immediately below the latch.
The latch shall be flip-over style, sliding or other hardware not Unit: Each
requiring grasping or twisting. Make certain that the inside and Minimum Estimated Cost: 269
outside door hardware is mounted no more than 48 inches
above the finished floor (see CBC 115B.7.1.3 and ADAAG Maximum Estimated Cost: 269
4.13.9). Record Number 1018
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 488 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the coat hook on the standard stall door and
alternate stall door designated to be accessible in the restroom
is greater than 48 inches above the floor surface.

Alternative *
Rec:
(Where
Available)

Women's Restroom Outside of Building 3

Full Rec Remount the coat hook on the stall door designated to be Citation CBC 1115B.9.2; ADAAG A4.27
accessible in the restroom to a maximum height of 48 inches
above the floor surface.
Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 1019
Priority:

Restrooms
Finding: The height of the side grab bars in the standard stall and the
alternate stall designated to be accessible of the restroom is
less than 33 inches above the finished floor.

Alternative *
Rec:
(Where
Available)

Women's Restroom Outside of Building 3

Full Rec Remount the side grab bars in the standard stall and alternate Citation CBC 1115B.8.1; ADAAG 4.26
stall designated to be accessible in the restroom so that the
height of the gripping surface is centered at 33 inches above
finished floor. Grab bars must be able to support a point load of Minimum Quantity 1
at least 250 pounds and shall be less than the allowable shear Maximum Quantity: 1
stress of the grab bar material.
Unit: Each
Minimum Estimated Cost: 448
Maximum Estimated Cost: 448
Record Number 1020
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 489 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The distance from the end of the back grab bar to the nearest
side wall in the stall designated to be accessible of the restroom
is greater than 6 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom Outside of Building 3

Full Rec Remount the back grab bar in the stall designated to be Citation ADAAG 4.26; CBC 1115B.8.1
accessible in the restroom so that it is not more than 6 inches
from the nearest side wall (see ADAAG 4.26 and CBC Figure
11B.1A-1C). Grab bars must be able to support a point load of Minimum Quantity 1
at least 250 pounds and shall be less than the allowable shear Maximum Quantity: 1
stress of the grab bar material.
Unit: Each
Minimum Estimated Cost: 448
Maximum Estimated Cost: 448
Record Number 1021
Priority:

Restrooms
Finding: The distance from the end of the side grab bars to the back wall
in the alternate stall designated to be accessible in the restroom
is greater than 12 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom Outside of Building 3

Full Rec Remount the side grab bars in the alternate stall designated to Citation CBC 1115B.8.1; ADAAG 4.26
be accessible in the restroom so that it is not more than 12
inches from the back wall (see ADAAG Figure 29 and CBC
1115B.8). Grab bars must be able to support a point load of at Minimum Quantity 1
least 250 pounds and shall be less than the allowable shear Maximum Quantity: 1
stress of the grab bar material.
Unit: Each
Minimum Estimated Cost: 448
Maximum Estimated Cost: 448
Record Number 1022
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 490 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The location of the toilet paper dispenser in the standard stall
designated to be accessible in the restroom is not within 12
inches of the front edge of the toilet seat. The toilet paper
dispenser in the alternate stall designated to be accessible in
the restroom protrudes more than 4 inches from the side wall
and interferes with the clear floor space of the water closet.

Alternative *
Rec:
(Where
Available)

Women's Restroom Outside of Building 3

Full Rec Remount the toilet paper dispenser in the standard stall and Citation CBC 1115B.9.3; ADAAG 4.16.6
alternate stall designated to be accessible in the restroom so
that it is within 12 inches from the front edge of the toilet seat
(see CBC 1115B.9.3 and ADAAG Figure 29(b)). Toilet paper Minimum Quantity 1
dispensers must allow continuous paper flow and shall not Maximum Quantity: 1
interfere with the use of the side grab bar.
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 1023
Priority:

Restrooms
Finding: The flush control on the toilet in the alternate stall designated to
be accessible in the restroom is not on the wide (approach) side
of the toilet.

Alternative *
Rec:
(Where
Available)

Women's Restroom Outside of Building 3

Full Rec Relocate the flush control on the toilet in the alternate stall Citation ADAAG 4.16.5; ADAAG 4.27.4
designated to be accessible in the restroom so that it is on the
wide (approach) side of the toilet area (see ADAAG 4.16.5).
Flush controls shall be hand-operated or automatic mechanisms. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 127
Maximum Estimated Cost: 127
Record Number 1024
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 491 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The distance from the center of the toilet to the nearest side
wall in the standard stall and alternate stall designated to be
accessible in the restroom is less than 18 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom Outside of Building 3

Full Rec Relocate the toilet or stall side wall so that the distance from the Citation CBC 1115B.7.1.3 ADAAG 4.17.3
centerline of the toilet to the nearest side wall in the standard
stall and alternate stall designated to be accessible in the
restroom is exactly 18 inches (see ADAAG Figure 28. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1143
Maximum Estimated Cost: 1143
Record Number 1025
Priority:

Restrooms
Finding: The seat cover dispenser in the standard stall and alternate stall
designated to be accessible in the restroom is mounted at a
height greater than 40 inches and there is no clear floor space.

Alternative *
Rec:
(Where
Available)

Women's Restroom Outside of Building 3

Full Rec Relocate the seat cover dispenser in the stall designated to be Citation CBC 1115B.9.2
accessible in the restroom so that the height is no greater than
40 inches above the finished floor (see CBC 1115B.9.2). Make
certain that the location of the seat cover dispenser does not Minimum Quantity 1
interfere with the use of a grab bar and provides sufficient clear Maximum Quantity: 1
floor space.
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 1026
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 492 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The bottom edge of the reflecting surface of the mirror in the
restroom is greater than 40 inches above the finished floor.

Alternative *
Rec:
(Where
Available)

Women's Restroom Outside of Building 3

Full Rec Lower the mirror in the restroom so that the bottom edge of the Citation ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG
reflecting surface is no higher than 40 inches above the finished 4.19.6
floor and the topmost portion of the reflecting surface extends at
least 74 inches above the finished floor (see ADAAG A4.19.6). Minimum Quantity 1
A single, full-length mirror is recommended since it can Maximum Quantity: 1
accommodate all people. Make certain to provide a minimum
clear floor space in front of the mirror of 30 inches in width and Unit: Each
48 inches in length. Minimum Estimated Cost: 291
Maximum Estimated Cost: 291
Record Number 1027
Priority:

Restrooms
Finding: The height of the controls and operating mechanisms for the
soap dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom Outside of Building 3

Full Rec Relocate the soap dispenser in the restroom to a maximum Citation CBC 1115B.9.2; ADAAG A4.27
height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 1028
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 493 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the controls and operating mechanisms for the
paper towel dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom Outside of Building 3

Full Rec Relocate the paper towel dispenser in the restroom to a Citation CBC 1115B.9.2; ADAAG A4.27
maximum height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 1029
Priority:

Restrooms
Finding: The signage indicating accessibility on the latch side of the
entry door of the restroom is not centered at 60 inches above
the floor surface. There is no Title 24 gender use signage on
the entrance door.

Alternative *
Rec:
(Where
Available)

Women's Restroom Outside of the Grandstands (North


End)

Full Rec The restroom is designated accessible and should be made Citation CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7));
accessible for the facility. Post signage centered 60 inches ADAAG 4.1.6(3)(e); ADAAG 4.30
above the ground surface on the latch side of the entrance door
identifying the restroom as accessible upon completion of the Minimum Quantity 1
following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG Maximum Quantity: 1
4.1.6(3)(e). Signage shall include Braille and raised lettering,
the gender or unisex use symbol and the ISA symbol. Post Title Unit: Each
24 gender use signage on the door @ 60" o.c. a.f.f. Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 589
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 494 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The bottom 10 inches of the door does not provide a smooth,
uninterrupted surface, or panel to allow the door to be opened
by a wheelchair footrest without creating a trap or hazardous
condition, due to the door stop.

Alternative *
Rec:
(Where
Available)

Women's Restroom Outside of the Grandstands (North


End)

Full Rec Install a panel or replace the door to provide a smooth, Citation CBC 1133B.2.6
uninterrupted surface for the bottom 10 inches of the door.

Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 590
Priority:

Restrooms
Finding: The door in the standard stall designated to be accessible in the
restroom does not have appropriate accessible hardware.

Alternative *
Rec:
(Where
Available)

Women's Restroom Outside of the Grandstands (North


End)

Full Rec The latch shall be flip-over style, sliding or other hardware not Citation CBC 1115B.7.1.3; ADAAG 4.13.9
requiring grasping or twisting.

Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 189
Maximum Estimated Cost: 189
Record Number 591
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 495 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the coat hook on the standard stall door
designated to be accessible in the restroom is greater than 48
inches above the floor surface.

Alternative *
Rec:
(Where
Available)

Women's Restroom Outside of the Grandstands (North


End)

Full Rec Remount the coat hook on the stall door designated to be Citation CBC 1115B.9.2; ADAAG A4.27
accessible in the restroom to a maximum height of 48 inches
above the floor surface.
Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 592
Priority:

Restrooms
Finding: The height of the side grab bars in the alternate stall designated
to be accessible of the restroom is greater than 33 inches above
the finished floor.

Alternative *
Rec:
(Where
Available)

Women's Restroom Outside of the Grandstands (North


End)

Full Rec Remount the side grab bars in the stall designated to be Citation CBC 1115B.8.1; ADAAG 4.26
accessible in the restroom so that the height of the gripping
surface is centered at 33 inches above finished floor. Grab bars
must be able to support a point load of at least 250 pounds and Minimum Quantity 1
shall be less than the allowable shear stress of the grab bar Maximum Quantity: 1
material.
Unit: Each
Minimum Estimated Cost: 448
Maximum Estimated Cost: 448
Record Number 593
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 496 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The side grab bars in the standard stall and the alternate stall
designated to be accessible in the restroom does not extend 54
inches from the back wall.

Alternative *
Rec:
(Where
Available)

Women's Restroom Outside of the Grandstands (North


End)

Full Rec The front end of the grab bars shall extend at least 54 inches Citation CBC 1115B.8.1; ADAAG 4.26
from the back wall and the back end of the grab bar shall be
mounted within 12 inches from the back wall. Grab bars must
be able to support a point load of at least 250 pounds and shall Minimum Quantity 1
be less than the allowable shear stress of the grab bar material. Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 531
Maximum Estimated Cost: 531
Record Number 594
Priority:

Restrooms
Finding: The distance from the center of the toilet to the nearest side
wall in the standard stall designated to be accessible in the
restroom is greater than 18 inches. The distance from the
center of the toilet to the nearest side wall in the alternate stall
designated to be accessible in the restroom is less than 18
inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom Outside of the Grandstands (North


End)

Full Rec Relocate the toilet or stall side wall so that the distance from the Citation CBC 1115B.7.1.3 ADAAG 4.17.3
centerline of the toilet to the nearest side wall in the stall
designated to be accessible in the restroom is exactly 18 inches
(see ADAAG Figure 28. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1143
Maximum Estimated Cost: 1143
Record Number 595
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 497 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the controls and operating mechanisms for the
soap dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom Outside of the Grandstands (North


End)

Full Rec Relocate the soap dispenser in the restroom to a maximum Citation CBC 1115B.9.2; ADAAG A4.27
height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 596
Priority:

Restrooms
Finding: The height of the controls and operating mechanisms for the
paper towel dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Women's Restroom Outside of the Grandstands (North


End)

Full Rec Relocate the paper towel dispenser in the restroom to a Citation CBC 1115B.9.2; ADAAG A4.27
maximum height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 597
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 498 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: There is no signage indicating accessibility on the latch side of
the entry door of the restroom. The gender use signage is not
mounted on the entrance door and is not centered at 60 inches
above the floor surface.

Alternative *
Rec:
(Where
Available)

Women's Showers Next to L-2 and L-3

Full Rec The restroom is designated accessible and should be made Citation CBC 1115B.5; ADAAG 4.1.6; ADAAG 4.1.2(7));
accessible for the facility. Post signage centered 60 inches ADAAG 4.1.6(3)(e); ADAAG 4.30
above the ground surface on the latch side of the entrance door
identifying the restroom as accessible upon completion of the Minimum Quantity 1
following items (see CBC 1115B., ADAAG 4.1.2(7) and ADAAG Maximum Quantity: 1
4.1.6(3)(e). Signage shall include Braille and raised lettering,
the gender or unisex use symbol and the ISA symbol. Post Title Unit: Each
24 gender use signage on the door @ 60" o.c. a.f.f. Minimum Estimated Cost: 58
Maximum Estimated Cost: 58
Record Number 798
Priority:

Restrooms
Finding: This restroom is not accessible and cannot be easily altered.
There is not sufficient clear floor space in the restroom to
accommodate an individual in a wheelchair.

Alternative *
Rec:
(Where
Available)

Women's Showers Next to L-2 and L-3

Full Rec Consult a design professional to modify the restroom. One or Citation CBC 1115B.7.2; ADAAG 4.16.2
more walls may need to be moved to provide sufficient clear
floor space to inscribe a 60-inch diameter turning radius in the
restroom to accommodate an individual in a wheelchair. Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 799
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 499 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: There is insufficient clear floor space in the stall designated to
be accessible in the restroom. The stall door to the stall
designated to be accessible in the restroom swings inward
limiting the clear floor space in the stall designated to be
accessible. The door to the stall designated to be accessible in
the restroom does not have accessible hardware.

Alternative *
Rec:
(Where
Available)

Women's Showers Next to L-2 and L-3

Full Rec Modify or replace the stall designated to be accessible in the Citation CBC 1115B; ADAAG 4.17.3; ADAAG A4.17.3
restroom so that it complies with ADAAG 4.17.3, CBC 1115B
and CBC Figures 11B-1A and 1B. Standard accessible stalls
require 60 inches in width with 56 inches depth for wall-mounted Minimum Quantity 1
toilets or 59 inches depth for floor-mounted toilets to Maximum Quantity: 1
accommodate individuals in wheelchairs. The minimum width of
a front-approach doorway shall provide at least 32 inches and a Unit: Each
side-approach doorway shall provide at least 34 inches. The Minimum Estimated Cost: 4000
door shall swing outward, close automatically and provide
accessible hardware. Maximum Estimated Cost: 4000
Record Number 800
Priority:

Restrooms
Finding: There are no grab bars in the stall designated to be accessible
in the restroom.

Alternative *
Rec:
(Where
Available)

Women's Showers Next to L-2 and L-3

Full Rec Install one 36-inch back grab bar and one 42/48-inch side grab Citation CBC 1115B.8; ADAAG 4.26
bar in the stall designated to be accessible in the restroom.
Grab bars shall be mounted at a height of 33 inches above the
finished floor. Grab bars must be able to support a point load of Minimum Quantity 1
at least 250 pounds and shall be less than the allowable shear Maximum Quantity: 1
stress of the grab bar material.
Unit: Each
Minimum Estimated Cost: 531
Maximum Estimated Cost: 531
Record Number 801
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 500 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the toilet seat in the stall designated to be
accessible in the restroom is less than 17 inches above the
finished floor.

Alternative *
Rec:
(Where
Available)

Women's Showers Next to L-2 and L-3

Full Rec Remove or modify the toilet in the stall designated to be Citation ADAAG 4.16.3
accessible in the restroom so that the seat height is between 17
inches and 19 inches above the finished floor (see ADAAG
4.16.3). Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1707
Maximum Estimated Cost: 1707
Record Number 803
Priority:

Restrooms
Finding: The distance from the center of the toilet to the nearest side
wall in the stall designated to be accessible in the restroom is
less than 18 inches.

Alternative *
Rec:
(Where
Available)

Women's Showers Next to L-2 and L-3

Full Rec Relocate the toilet or stall side wall so that the distance from the Citation CBC 1115B.7.1.3 ADAAG 4.17.3
centerline of the toilet to the nearest side wall in the stall
designated to be accessible in the restroom is exactly 18 inches
(see ADAAG Figure 28. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1143
Maximum Estimated Cost: 1143
Record Number 804
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 501 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The seat cover dispenser in the stall designated to be
accessible in the restroom is mounted at a height greater than
40 inches and there is no clear floor space.

Alternative *
Rec:
(Where
Available)

Women's Showers Next to L-2 and L-3

Full Rec Relocate the seat cover dispenser in the stall designated to be Citation CBC 1115B.9.2
accessible in the restroom so that the height is no greater than
40 inches above the finished floor (see CBC 1115B.9.2). Make
certain that the location of the seat cover dispenser does not Minimum Quantity 1
interfere with the use of a grab bar and provides sufficient clear Maximum Quantity: 1
floor space.
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 805
Priority:

Restrooms
Finding: The faucet controls on the lavatory in the restroom require tight
grasping, pinching, or twisting of the wrist and are not
accessible.

Alternative *
Rec:
(Where
Available)

Women's Showers Next to L-2 and L-3

Full Rec Install faucet controls complying with ADAAG 4.19.5 on the Citation ADAAG 4.19.5
lavatory designated to be accessible in the restroom. Lever-
operated, push-type, touch-type or electronically controlled
mechanisms are acceptable elements (see ADAAG 4.19.5). If Minimum Quantity 1
self-closing valves are used the faucet shall remain open for at Maximum Quantity: 1
least 10 seconds.
Unit: Each
Minimum Estimated Cost: 392
Maximum Estimated Cost: 392
Record Number 806
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 502 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The distance from the center of the lavatory to the adjacent side
wall in the restroom is less than 18 inches.

Alternative *
Rec:
(Where
Available)

Women's Showers Next to L-2 and L-3

Full Rec Relocate the lavatory to provide a centerline of at least 18 Citation ADAAG 4.19.3
inches. Make sure to provide at least 30 inches in width and 48
inch length of clear floor space to allow an accessible forward
approach (see ADAAG 4.19.3). Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 807
Priority:

Restrooms
Finding: The knee clearance space under the lavatory designated to be
accessible in the restroom is less than 29 inches. The knee
depth space under the lavatory designated to be accessible in
the restroom is less than 27 inches at 8 inches under the
lavatory apron.

Alternative *
Rec:
(Where
Available)

Women's Showers Next to L-2 and L-3

Full Rec Replace the lavatory designated to be accessible in the Citation ADAAG 4.19.2
restroom to provide at least 29 inches of clear knee space
between the finished floor and bottom of the lavatory apron.
Make sure to provide at least 27 inches at 8 inches under the Minimum Quantity 1
apron (see ADAAG 4.19.2). Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 1286
Maximum Estimated Cost: 1286
Record Number 808
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 503 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The pipes under the lavatory in the restroom do not provide
protection against contact.

Alternative *
Rec:
(Where
Available)

Women's Showers Next to L-2 and L-3

Full Rec Insulate or otherwise configure pipes under the lavatory Citation ADAAG 4.19.4
designated to be accessible in the restroom to protect against
contact (see ADAAG 4.19.4). Make certain there are no sharp
or abrasive surfaces under the lavatory. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 39
Maximum Estimated Cost: 39
Record Number 809
Priority:

Restrooms
Finding: The bottom edge of the reflecting surface of the mirror in the
restroom is greater than 40 inches above the finished floor.

Alternative *
Rec:
(Where
Available)

Women's Showers Next to L-2 and L-3

Full Rec Lower the mirror in the restroom so that the bottom edge of the Citation ADAAG A4.19.6; CBC 1115B.9.1.2; ADAAG
reflecting surface is no higher than 40 inches above the finished 4.19.6
floor and the topmost portion of the reflecting surface extends at
least 74 inches above the finished floor (see ADAAG A4.19.6). Minimum Quantity 1
A single, full-length mirror is recommended since it can Maximum Quantity: 1
accommodate all people. Make certain to provide a minimum
clear floor space in front of the mirror of 30 inches in width and Unit: Each
48 inches in length. Minimum Estimated Cost: 291
Maximum Estimated Cost: 291
Record Number 810
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 504 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The height of the controls and operating mechanisms for the
soap dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Women's Showers Next to L-2 and L-3

Full Rec Relocate the soap dispenser in the restroom to a maximum Citation CBC 1115B.9.2; ADAAG A4.27
height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 811
Priority:

Restrooms
Finding: The height of the controls and operating mechanisms for the
paper towel dispenser in the restroom is greater than 40 inches.

Alternative *
Rec:
(Where
Available)

Women's Showers Next to L-2 and L-3

Full Rec Relocate the paper towel dispenser in the restroom to a Citation CBC 1115B.9.2; ADAAG A4.27
maximum height of 40 inches for all the controls and operating
mechanisms (see CBC 1115B.9.2).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 812
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 505 of 542


Facility Name: San Joaquin Fairgrounds
Restrooms
Finding: The women's restroom provides four private shower stalls.
There are no accessible shower stalls provided in the restroom.

Alternative *
Rec:
(Where
Available)

Women's Showers Next to L-2 and L-3

Full Rec Since shower stalls are provided in the restroom, at least one Citation CBC 1115B.6.2; ADAAG 4.21
accessible shower stall is required. Install an accessible shower
stall complying with CBC 1115B 6.2 and ADAAG 4.21 in the
restroom. Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 2853
Maximum Estimated Cost: 2853
Record Number 813
Priority:

Drinking Fountains
Finding: There are 13 drinking fountains on primary paths of travel.

Alternative *
Rec:
(Where
Available)

Full Rec Fifty percent of the drinking fountains on primary paths of travel Citation CBC 1117B.1; ADAAG 4.15
shall be accessible (see CBC 1117B.1 and ADAAG 4.15).
Install a "high-low" fountain design to comply with both state and
federal requirement. Fountains not located in alcoves need side Minimum Quantity 1
rails or wing walls on both sides. Maximum Quantity: 1
Unit: None Selected
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 1143
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 506 of 542


Facility Name: San Joaquin Fairgrounds
Drinking Fountains
Finding: The spout outlet height is greater than 36 inches. There is less
than 27 inches knee clearance height. The drinking fountain
does not have accessible fountain controls and requires the use
of foot controls to operate.

Alternative *
Rec:
(Where
Available)

Drinking Fountain at the West Entrance of Building 2

Full Rec Fifty percent of the drinking fountains on primary paths of travel Citation CBC 1117B.1; ADAAG 4.15
shall be accessible (see CBC 1117B.1 and ADAAG 4.15).
Install a "high-low" fountain design to comply with both state and
federal requirements and install a side rail or wing wall next to Minimum Quantity 1
each side of the fountain. The height of the spout outlet shall Maximum Quantity: 1
not exceed 36 inches in height. Fountain controls shall be
accessible. Wall-mounted drinking fountains shall provide a Unit: Each
minimum knee clearance height of 27 inches, 30 inches in width Minimum Estimated Cost: 2216
and between 18 inches and 19 inches in fountain depth.
Maximum Estimated Cost: 2216
Record Number 664
Priority:

Drinking Fountains
Finding: The drinking fountain is not a "high-low" design. The water
trajectory is diagonal to the front of the unit.

Alternative *
Rec:
(Where
Available)

Drinking Fountain in Building 1 (East Entrance)

Full Rec Fifty percent of the drinking fountains on primary paths of travel Citation CBC 1117B.1; ADAAG 4.15
shall be accessible (see CBC 1117B.1 and ADAAG 4.15).
Install a "high-low" fountain design to comply with both state and
federal requirements and install a side rail or wing wall next to Minimum Quantity 1
each side of the fountain. The spout shall direct the water flow Maximum Quantity: 1
at least 4 inches high and in a trajectory that is parallel or nearly
parallel to the front of the drinking fountain. Unit: Each
Minimum Estimated Cost: 2216
Maximum Estimated Cost: 2216
Record Number 1145
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 507 of 542


Facility Name: San Joaquin Fairgrounds
Drinking Fountains
Finding: The drinking fountain is not a "high-low" design. The spout
outlet height is greater than 36 inches. The faucet controls
require the use of foot controls to operate. There is less than 27
inches knee clearance height.

Alternative *
Rec:
(Where
Available)

Drinking Fountain in Building 1 (North Entrance)

Full Rec Fifty percent of the drinking fountains on primary paths of travel Citation CBC 1117B.1; ADAAG 4.15
shall be accessible (see CBC 1117B.1 and ADAAG 4.15).
Install a "high-low" fountain design to comply with both state and
federal requirements and install a side rail or wing wall next to Minimum Quantity 1
each side of the fountain. The height of the spout outlet shall Maximum Quantity: 1
not exceed 36 inches in height. Fountain controls shall be
accessible. Wall-mounted drinking fountains shall provide a Unit: Each
minimum knee clearance height of 27 inches, 30 inches in width Minimum Estimated Cost: 2216
and between 18 inches and 19 inches in fountain depth.
Maximum Estimated Cost: 2216
Record Number 1153
Priority:

Drinking Fountains
Finding: The drinking fountain is not a "high-low" design. The spout
outlet height is greater than 36 inches. There is less than 27
inches knee clearance height.

Alternative *
Rec:
(Where
Available)

Drinking Fountain in Building 2 (North Entrance)

Full Rec Fifty percent of the drinking fountains on primary paths of travel Citation CBC 1117B.1; ADAAG 4.15
shall be accessible (see CBC 1117B.1 and ADAAG 4.15).
Install a "high-low" fountain design to comply with both state and
federal requirements and install a side rail or wing wall next to Minimum Quantity 1
each side of the fountain. The height of the spout outlet shall Maximum Quantity: 1
not exceed 36 inches in height. Wall-mounted drinking
fountains shall provide a minimum knee clearance height of 27 Unit: Each
inches, 30 inches in width and between 18 inches and 19 inches Minimum Estimated Cost: 2216
in fountain depth.
Maximum Estimated Cost: 2216
Record Number 1152
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 508 of 542


Facility Name: San Joaquin Fairgrounds
Drinking Fountains
Finding: The drinking fountain is not a "high-low" design. The spout
outlet height is greater than 36 inches. There is less than 27
inches knee clearance height.

Alternative *
Rec:
(Where
Available)

Drinking Fountain in Building 2 (South Entrance)

Full Rec Fifty percent of the drinking fountains on primary paths of travel Citation CBC 1117B.1; ADAAG 4.15
shall be accessible (see CBC 1117B.1 and ADAAG 4.15).
Install a "high-low" fountain design to comply with both state and
federal requirements and install a side rail or wing wall next to Minimum Quantity 1
each side of the fountain. The height of the spout outlet shall Maximum Quantity: 1
not exceed 36 inches in height. Wall-mounted drinking
fountains shall provide a minimum knee clearance height of 27 Unit: Each
inches, 30 inches in width and between 18 inches and 19 inches Minimum Estimated Cost: 2216
in fountain depth.
Maximum Estimated Cost: 2216
Record Number 1151
Priority:

Drinking Fountains
Finding: The spout outlet height is greater than 36 inches. The faucet
controls require the use of foot controls to operate. There is
less than 27 inches knee clearance height. The drinking
fountain is not a "high-low" design.

Alternative *
Rec:
(Where
Available)

Drinking Fountain in Building 2 (West Entrance)

Full Rec Fifty percent of the drinking fountains on primary paths of travel Citation CBC 1117B.1; ADAAG 4.15
shall be accessible (see CBC 1117B.1 and ADAAG 4.15).
Install a "high-low" fountain design to comply with both state and
federal requirements and install a side rail or wing wall next to Minimum Quantity 1
each side of the fountain. The height of the spout outlet shall Maximum Quantity: 1
not exceed 36 inches in height. Fountain controls shall be
accessible. Wall-mounted drinking fountains shall provide a Unit: Each
minimum knee clearance height of 27 inches, 30 inches in width Minimum Estimated Cost: 2216
and between 18 inches and 19 inches in fountain depth.
Maximum Estimated Cost: 2216
Record Number 1144
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 509 of 542


Facility Name: San Joaquin Fairgrounds
Drinking Fountains
Finding: The spout outlet height is greater than 36 inches. The faucet
controls require the use of foot controls to operate. There is
less than 27 inches knee clearance height. The drinking
fountain is not a "high-low" design.

Alternative *
Rec:
(Where
Available)

Drinking Fountain in Building 6

Full Rec Fifty percent of the drinking fountains on primary paths of travel Citation CBC 1117B.1; ADAAG 4.15
shall be accessible (see CBC 1117B.1 and ADAAG 4.15).
Install a "high-low" fountain design to comply with both state and
federal requirements and install a side rail or wing wall next to Minimum Quantity 1
each side of the fountain. The height of the spout outlet shall Maximum Quantity: 1
not exceed 36 inches in height. Fountain controls shall be
accessible. Wall-mounted drinking fountains shall provide a Unit: Each
minimum knee clearance height of 27 inches, 30 inches in width Minimum Estimated Cost: 2216
and between 18 inches and 19 inches in fountain depth.
Maximum Estimated Cost: 2216
Record Number 1147
Priority:

Drinking Fountains
Finding: The drinking fountain is not a "high-low" design. The spout
outlet height is greater than 36 inches. There is less than 27
inches knee clearance height.

Alternative *
Rec:
(Where
Available)

Drinking Fountain in the Grandstands (East End)

Full Rec Fifty percent of the drinking fountains on primary paths of travel Citation CBC 1117B.1; ADAAG 4.15
shall be accessible (see CBC 1117B.1 and ADAAG 4.15).
Install a "high-low" fountain design to comply with both state and
federal requirements and install a side rail or wing wall next to Minimum Quantity 1
each side of the fountain. The height of the spout outlet shall Maximum Quantity: 1
not exceed 36 inches in height. Wall-mounted drinking
fountains shall provide a minimum knee clearance height of 27 Unit: Each
inches, 30 inches in width and between 18 inches and 19 inches Minimum Estimated Cost: 2216
in fountain depth.
Maximum Estimated Cost: 2216
Record Number 1150
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 510 of 542


Facility Name: San Joaquin Fairgrounds
Drinking Fountains
Finding: The drinking fountain is not a "high-low" design. The faucet
controls require tight grasping or pinching of the wrist to operate.

Alternative *
Rec:
(Where
Available)

Drinking Fountain in the Jockey's Quarters

Full Rec Fifty percent of the drinking fountains on primary paths of travel Citation CBC 1117B.1; ADAAG 4.15
shall be accessible (see CBC 1117B.1 and ADAAG 4.15).
Install a "high-low" fountain design to comply with both state and
federal requirements and install a side rail or wing wall next to Minimum Quantity 1
each side of the fountain. Fountain controls shall be accessible. Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 2216
Maximum Estimated Cost: 2216
Record Number 1146
Priority:

Drinking Fountains
Finding: The drinking fountain is not a "high-low" design.

Alternative *
Rec:
(Where
Available)

Drinking Fountain Next to the Restrooms in the Winner's


Building

Full Rec Fifty percent of the drinking fountains on primary paths of travel Citation CBC 1117B.1; ADAAG 4.15
shall be accessible (see CBC 1117B.1 and ADAAG 4.15).
Install a "high-low" fountain design to comply with both state and
federal requirements and install a side rail or wing wall next to Minimum Quantity 1
each side of the fountain. Provide at least 30 inches in width Maximum Quantity: 1
and 48 inches in depth in front of the drinking fountain. The
height of the spout outlet shall not exceed 36 inches in height. Unit: Each
Fountain controls shall be accessible. The spout shall direct the Minimum Estimated Cost: 2216
water flow at least 4 inches high and in a trajectory that is
parallel or nearly parallel to the front of the drinking fountain. Maximum Estimated Cost: 2216
Wall-mounted drinking fountains shall provide a minimum knee Record Number 1149
clearance height of 27 inches, 30 inches in width and between Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 511 of 542


Facility Name: San Joaquin Fairgrounds
Drinking Fountains
Finding: The drinking fountain is not a "high-low" design. The spout
outlet height is greater than 36 inches. There is less than 27
inches knee clearance height.

Alternative *
Rec:
(Where
Available)

Drinking Fountains Next to the Restrooms in the


Grandstands

Full Rec Fifty percent of the drinking fountains on primary paths of travel Citation CBC 1117B.1; ADAAG 4.15
shall be accessible (see CBC 1117B.1 and ADAAG 4.15).
Install a "high-low" fountain design to comply with both state and
federal requirements and install a side rail or wing wall next to Minimum Quantity 1
each side of the fountain. The height of the spout outlet shall Maximum Quantity: 2
not exceed 36 inches in height. Wall-mounted drinking
fountains shall provide a minimum knee clearance height of 27 Unit: Each
inches, 30 inches in width and between 18 inches and 19 inches Minimum Estimated Cost: 2216
in fountain depth.
Maximum Estimated Cost: 4432
Record Number 1148
Priority:

Commons or Lunch Area


Finding: The height of the tray slides is greater than 34 inches.

Alternative *
Rec:
(Where
Available)

Building 2 Kitchen

Full Rec Lower the tray slides to a height no greater than 34 inches Citation CBC 1104B.5.5; ADAAG 5.5; ADAAG 4.32.5(3);
above the finished floor (see CBC 1104B.5.5 and ADAAG 5.5). ADAAG A4.2.5; ADAAG A4.2.6

Minimum Quantity 1
Maximum Quantity: 1
Unit: 30 Linear Feet
Minimum Estimated Cost: 2400
Maximum Estimated Cost: 2400
Record Number 355
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 512 of 542


Facility Name: San Joaquin Fairgrounds
Commons or Lunch Area
Finding: The height of the concession counter at the north end of the
Grandstand is greater than 36 inches.

Alternative *
Rec:
(Where
Available)

Concession Counter at the Grandstand (North End)

Full Rec Lower the concession counter to a height between 28 inches Citation ADAAG 7.2
and 36 inches above the ground level (see ADAAG 7.2).

Minimum Quantity 1
Maximum Quantity: 1
Unit: 3 Linear Feet
Minimum Estimated Cost: 129
Maximum Estimated Cost: 129
Record Number 1165
Priority:

Commons or Lunch Area


Finding: The height of the concession counter at the north end of the
Grandstands is greater than 36 inches.

Alternative *
Rec:
(Where
Available)

Concession Counter at the Granstands (North End)

Full Rec Lower the concession counter to a height between 28 inches Citation ADAAG 7.2
and 36 inches above the ground level (see ADAAG 7.2).

Minimum Quantity 1
Maximum Quantity: 1
Unit: 3 Linear Feet
Minimum Estimated Cost: 129
Maximum Estimated Cost: 129
Record Number 1171
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 513 of 542


Facility Name: San Joaquin Fairgrounds
Commons or Lunch Area
Finding: The height of the concession counter on the north end of the
second level of the Grandstands is greater than 36 inches.

Alternative *
Rec:
(Where
Available)

Concession Counter at the Granstands (North End)

Full Rec Lower the concession counter to a height between 28 inches Citation ADAAG 7.2
and 36 inches above the ground level (see ADAAG 7.2).

Minimum Quantity 1
Maximum Quantity: 1
Unit: 3 Linear Feet
Minimum Estimated Cost: 129
Maximum Estimated Cost: 129
Record Number 1172
Priority:

Commons or Lunch Area


Finding: The height of the concession counter at the south end of the
second level in the Grandstands is greater than 36 inches.

Alternative *
Rec:
(Where
Available)

Concession Counter in the Grandstands (South End)

Full Rec Lower the concession counter to a height between 28 inches Citation ADAAG 7.2
and 36 inches above the ground level (see ADAAG 7.2).

Minimum Quantity 1
Maximum Quantity: 2
Unit: 3 Linear Feet
Minimum Estimated Cost: 129
Maximum Estimated Cost: 258
Record Number 1175
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 514 of 542


Facility Name: San Joaquin Fairgrounds
Commons or Lunch Area
Finding: The height of the concession counter outside of Building 2 is
greater than 36 inches.

Alternative *
Rec:
(Where
Available)

Concession Counter Outside of Building 2 (South End)

Full Rec Lower the concession counter to a height between 28 inches Citation ADAAG 7.2
and 36 inches above the ground level (see ADAAG 7.2).

Minimum Quantity 1
Maximum Quantity: 1
Unit: 3 Linear Feet
Minimum Estimated Cost: 129
Maximum Estimated Cost: 129
Record Number 1156
Priority:

Commons or Lunch Area


Finding: The height of the concession counter outside of the FFA Office
is greater than 36 inches.

Alternative *
Rec:
(Where
Available)

Concession Counter Outside of the FFA Office

Full Rec Lower the concession counter to a height between 28 inches Citation ADAAG 7.2
and 36 inches above the ground level (see ADAAG 7.2).

Minimum Quantity 1
Maximum Quantity: 1
Unit: 3 Linear Feet
Minimum Estimated Cost: 129
Maximum Estimated Cost: 129
Record Number 1166
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 515 of 542


Facility Name: San Joaquin Fairgrounds
Commons or Lunch Area
Finding: The table top height is greater than 34 inches.

Alternative *
Rec:
(Where
Available)

Dining Area in the Grandstands

Full Rec Modify or replace one of the tables in the cafeteria to provide Citation CBC 1122B.3; ADAAG 4.32.2; ADAAG 4.32.5(2)
knee clearance of at least 27 inches in height, 30 inches in
width and 19 inches in depth (see CBC 1122B.3, ADAAG 4.32.2
and ADAAG Figure 45). The table top height shall not exceed Minimum Quantity 1
34 inches above the finished floor. Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 174
Maximum Estimated Cost: 174
Record Number 1174
Priority:

Commons or Lunch Area


Finding: The height of the sales counter in Flats BBQ is greater than 34
inches.

Alternative *
Rec:
(Where
Available)

Flats BBQ

Full Rec Lower the sales counter to a height between 28 inches and 34 Citation CBC 1122B.4; ADAAG 4.32.4; ADAAG 4.32.5(3)
inches from the finished floor (see CBC 1122B.4 and ADAAG
4.32.4).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 348
Maximum Estimated Cost: 348
Record Number 342
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 516 of 542


Facility Name: San Joaquin Fairgrounds
Commons or Lunch Area
Finding: The height of the food service counter is greater than 34 inches.

Alternative *
Rec:
(Where
Available)

Food Service Counter in Building 2 (South End)

Full Rec Lower the food service counter to a height no greater than 34 Citation CBC 1104B.5.5; ADAAG 5.5; ADAAG 4.32.5(3);
inches above the finished floor (see CBC 1104B.5.5 and ADAAG A4.2.5; ADAAG A4.2.6
ADAAG 5.5).
Minimum Quantity 1
Maximum Quantity: 1
Unit: 30 Linear Feet
Minimum Estimated Cost: 2400
Maximum Estimated Cost: 2400
Record Number 1154
Priority:

Commons or Lunch Area


Finding: The height of the north west concession counter at the
Grandstands is greater than 36 inches.

Alternative *
Rec:
(Where
Available)

Grandstands

Full Rec Lower the concession counter to a height between 28 inches Citation ADAAG 7.2
and 36 inches above the ground level (see ADAAG 7.2).

Minimum Quantity 1
Maximum Quantity: 1
Unit: 3 Linear Feet
Minimum Estimated Cost: 129
Maximum Estimated Cost: 129
Record Number 352
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 517 of 542


Facility Name: San Joaquin Fairgrounds
Commons or Lunch Area
Finding: There is no level landing provided at the concession counter.

Alternative *
Rec:
(Where
Available)

Grandstands

Full Rec Provide a level and clear landing at least 60 inches in length at Citation CBC 1133B.2.4.2; ADAAG 4.13.6
the concession counter.

Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 353
Priority:

Commons or Lunch Area


Finding: The height of the south east concession counter in the
Grandstands is greater than 36 inches.

Alternative *
Rec:
(Where
Available)

Grandstands

Full Rec Lower the concession counter to a height between 28 inches Citation ADAAG 7.2
and 36 inches above the ground level (see ADAAG 7.2).

Minimum Quantity 1
Maximum Quantity: 1
Unit: 3 Linear Feet
Minimum Estimated Cost: 129
Maximum Estimated Cost: 129
Record Number 358
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 518 of 542


Facility Name: San Joaquin Fairgrounds
Commons or Lunch Area
Finding: The height of the north east concession counter in the
Grandstands is greater than 36 inches.

Alternative *
Rec:
(Where
Available)

Grandstands

Full Rec Lower the concession counter to a height between 28 inches Citation ADAAG 7.2
and 36 inches above the ground level (see ADAAG 7.2).

Minimum Quantity 1
Maximum Quantity: 1
Unit: 3 Linear Feet
Minimum Estimated Cost: 129
Maximum Estimated Cost: 129
Record Number 360
Priority:

Commons or Lunch Area


Finding: The height of the bar counter is greater than 34 inches.

Alternative *
Rec:
(Where
Available)

Grandstands (Second Level)

Full Rec Lower the bar counter to a height between 28 inches and 34 Citation CBC 1122B.4; ADAAG 4.32.4; ADAAG 4.32.5(3)
inches from the finished floor (see CBC 1122B.4 and ADAAG
4.32.4).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 348
Maximum Estimated Cost: 348
Record Number 1173
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 519 of 542


Facility Name: San Joaquin Fairgrounds
Commons or Lunch Area
Finding: The height of the concession counter in the Linden Lions
Building is greater than 36 inches.

Alternative *
Rec:
(Where
Available)

Linden Lions

Full Rec Lower the concession counter to a height between 28 inches Citation ADAAG 7.2
and 36 inches above the ground level (see ADAAG 7.2).

Minimum Quantity 1
Maximum Quantity: 1
Unit: 3 Linear Feet
Minimum Estimated Cost: 129
Maximum Estimated Cost: 129
Record Number 351
Priority:

Commons or Lunch Area


Finding: The knee space at the tables is less than 19 inches deep.

Alternative *
Rec:
(Where
Available)

Lyndon Lions Building

Full Rec Modify or replace one of the tables to provide knee clearance of Citation CBC 1122B.3; ADAAG 4.32.2; ADAAG 4.32.5(2)
at least 27 inches in height, 30 inches in width and 19 inches in
depth (see CBC 1122B.3, ADAAG 4.32.2 and ADAAG Figure
45). The table top height shall not exceed 34 inches above the Minimum Quantity 1
finished floor. Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 174
Maximum Estimated Cost: 174
Record Number 1170
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 520 of 542


Facility Name: San Joaquin Fairgrounds
Commons or Lunch Area
Finding: The height of the concession counter at the Lyndon Lions Club
is greater than 36 inches.

Alternative *
Rec:
(Where
Available)

Lyndon Lions Club

Full Rec Lower the concession counter to a height between 28 inches Citation ADAAG 7.2
and 36 inches above the ground level (see ADAAG 7.2).

Minimum Quantity 1
Maximum Quantity: 1
Unit: 3 Linear Feet
Minimum Estimated Cost: 129
Maximum Estimated Cost: 129
Record Number 1164
Priority:

Commons or Lunch Area


Finding: The knee space at the tables in the outdoor dining area at
Building 2 is less than 19 inches deep.

Alternative *
Rec:
(Where
Available)

Outdoor Dining Area

Full Rec Modify or replace one of the tables in the outdoor dining area to Citation CBC 1122B.3; ADAAG 4.32.2; ADAAG 4.32.5(2)
provide knee clearance of at least 27 inches in height, 30 inches
in width and 19 inches in depth (see CBC 1122B.3, ADAAG
4.32.2 and ADAAG Figure 45). The table top height shall not Minimum Quantity 1
exceed 34 inches above the finished floor. Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 174
Maximum Estimated Cost: 174
Record Number 1155
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 521 of 542


Facility Name: San Joaquin Fairgrounds
Commons or Lunch Area
Finding: There is no accessible route to the picnic tables in the outdoor
dining area outside of Flat's BBQ. The surface under and
around the outdoor dining area picnic tables is dirt, preventing
access of individuals with mobility impairments.

Alternative *
Rec:
(Where
Available)

Outdoor Dining Area Outside of Flats BBQ

Full Rec Install a 48-inch wide path to the picnic tables in the outdoor Citation ADAAG 5.8; ADAAG A4.2.5; ADAAG A4.2.6
dining area that provides a smooth, stable, firm and slip
resistant surface. Provide a maneuvering space sufficient to
provide a 60-inch diameter turning radius adjacent to at least Minimum Quantity 1
one of the picnic tables in the outdoor dining area. Maximum Quantity: 1
Unit: 4' x 60'
Minimum Estimated Cost: 1440
Maximum Estimated Cost: 1440
Record Number 1162
Priority:

Commons or Lunch Area


Finding: The knee space at the tables in the outdoor dining area is less
than 19 inches deep.

Alternative *
Rec:
(Where
Available)

Outdoor Dining Area Outside of Flats BBQ

Full Rec Modify or replace one of the tables in the outdoor dining area to Citation CBC 1122B.3; ADAAG 4.32.2; ADAAG 4.32.5(2)
provide knee clearance of at least 27 inches in height, 30 inches
in width and 19 inches in depth (see CBC 1122B.3, ADAAG
4.32.2 and ADAAG Figure 45). The table top height shall not Minimum Quantity 1
exceed 34 inches above the finished floor. Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 174
Maximum Estimated Cost: 174
Record Number 1163
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 522 of 542


Facility Name: San Joaquin Fairgrounds
Commons or Lunch Area
Finding: The knee space at the tables in the outdoor dining area outside
of the Champion's Room at the Winner's Gaming and Sports
Emporium is less than 19 inches deep.

Alternative *
Rec:
(Where
Available)

Outdoor Dining Area Outside of the Champion's Room

Full Rec Modify or replace one of the tables in the outdoor dining area to Citation CBC 1122B.3; ADAAG 4.32.2; ADAAG 4.32.5(2)
provide knee clearance of at least 27 inches in height, 30 inches
in width and 19 inches in depth (see CBC 1122B.3, ADAAG
4.32.2 and ADAAG Figure 45). The table top height shall not Minimum Quantity 1
exceed 34 inches above the finished floor. Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 174
Maximum Estimated Cost: 174
Record Number 1167
Priority:

Commons or Lunch Area


Finding: The knee space at the table in the outdoor dining area is less
than 19 inches deep.

Alternative *
Rec:
(Where
Available)

Picnic Table South of the Administration Office

Full Rec Modify or replace one of the tables in the outdoor dining area to Citation CBC 1122B.3; ADAAG 4.32.2; ADAAG 4.32.5(2)
provide knee clearance of at least 27 inches in height, 30 inches
in width and 19 inches in depth (see CBC 1122B.3, ADAAG
4.32.2 and ADAAG Figure 45). The table top height shall not Minimum Quantity 1
exceed 34 inches above the finished floor. Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 174
Maximum Estimated Cost: 174
Record Number 1157
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 523 of 542


Facility Name: San Joaquin Fairgrounds
Commons or Lunch Area
Finding: The picnic tables are nonaccessible by design.

Alternative *
Rec:
(Where
Available)

Picnic Tables in the Grandstands

Full Rec Modify or replace one of the tables in the Grandstands to Citation CBC 1122B.3; ADAAG 4.32.2; ADAAG 4.32.5(2)
provide knee clearance of at least 27 inches in height, 30 inches
in width and 19 inches in depth (see CBC 1122B.3, ADAAG
4.32.2 and ADAAG Figure 45). The table top height shall not Minimum Quantity 1
exceed 34 inches above the finished floor. Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 174
Maximum Estimated Cost: 174
Record Number 1176
Priority:

Commons or Lunch Area


Finding: There is no accessible route to the picnic tables in the outdoor
dining area next to L-1.

Alternative *
Rec:
(Where
Available)

Picnic Tables Next to L-1

Full Rec Install a 48-inch wide path to the picnic tables in the outdoor Citation ADAAG 5.8; ADAAG A4.2.5; ADAAG A4.2.6
dining area that provides a smooth, stable, firm and slip
resistant surface. Provide a maneuvering space sufficient to
provide a 60-inch diameter turning radius adjacent to at least Minimum Quantity 1
one of the picnic tables in the outdoor dining area. Maximum Quantity: 1
Unit: 4' x 60'
Minimum Estimated Cost: 1440
Maximum Estimated Cost: 1440
Record Number 219
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 524 of 542


Facility Name: San Joaquin Fairgrounds
Commons or Lunch Area
Finding: The tables at the outdoor dining area next to L-1 are
nonaccessible by design.

Alternative *
Rec:
(Where
Available)

Picnic Tables Next to L-1

Full Rec Modify or replace one of the tables in the outdoor dining area to Citation CBC 1122B.3; ADAAG 4.32.2; ADAAG 4.32.5(2)
provide knee clearance of at least 27 inches in height, 30 inches
in width and 19 inches in depth (see CBC 1122B.3, ADAAG
4.32.2 and ADAAG Figure 45). The table top height shall not Minimum Quantity 1
exceed 34 inches above the finished floor. Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 174
Maximum Estimated Cost: 174
Record Number 220
Priority:

Commons or Lunch Area


Finding: The height of the concession counter at the east end of the
Stockton Motorplex is greater than 36 inches.

Alternative *
Rec:
(Where
Available)

Stockton Motorplex

Full Rec Lower the concession counter to a height between 28 inches Citation ADAAG 7.2
and 36 inches above the ground level (see ADAAG 7.2).

Minimum Quantity 1
Maximum Quantity: 1
Unit: 3 Linear Feet
Minimum Estimated Cost: 129
Maximum Estimated Cost: 129
Record Number 347
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 525 of 542


Facility Name: San Joaquin Fairgrounds
Commons or Lunch Area
Finding: The height of the bar counter is greater than 34 inches.

Alternative *
Rec:
(Where
Available)

Winners Gaming and Sports Emporium

Full Rec Lower the bar counter to a height between 28 inches and 34 Citation CBC 1122B.4; ADAAG 4.32.4; ADAAG 4.32.5(3)
inches from the finished floor (see CBC 1122B.4 and ADAAG
4.32.4).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 348
Maximum Estimated Cost: 348
Record Number 346
Priority:

Commons or Lunch Area


Finding: The height of the bar counter in the Champion's Room at the
Winner's Gaming and Sports Emporium is greater than 34
inches.

Alternative *
Rec:
(Where
Available)

Winner's Gaming and Sports Emporium

Full Rec Lower the bar counter to a height between 28 inches and 34 Citation CBC 1122B.4; ADAAG 4.32.4; ADAAG 5.2
inches from the finished floor (see CBC 1122B.4 and ADAAG
4.32.4).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 348
Maximum Estimated Cost: 348
Record Number 1158
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 526 of 542


Facility Name: San Joaquin Fairgrounds
Commons or Lunch Area
Finding: The knee space at the tables in the outdoor dining area is less
than 19 inches deep.

Alternative *
Rec:
(Where
Available)

Winner's Gaming and Sports Emporium

Full Rec Modify or replace one of the tables in the outdoor dining area to Citation CBC 1122B.3; ADAAG 4.32.2; ADAAG 4.32.5(2)
provide knee clearance of at least 27 inches in height, 30 inches
in width and 19 inches in depth (see CBC 1122B.3, ADAAG
4.32.2 and ADAAG Figure 45). The table top height shall not Minimum Quantity 1
exceed 34 inches above the finished floor. Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 174
Maximum Estimated Cost: 174
Record Number 1159
Priority:

Commons or Lunch Area


Finding: The height of the grill food service counter is greater than 34
inches.

Alternative *
Rec:
(Where
Available)

Winner's Gaming and Sports Emporium

Full Rec Lower the food service counter to a height between 28 inches Citation CBC 1122B.4; ADAAG 4.32.4; ADAAG 4.32.5(3)
and 34 inches from the finished floor (see CBC 1122B.4 and
ADAAG 4.32.4).
Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 348
Maximum Estimated Cost: 348
Record Number 1161
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 527 of 542


Facility Name: San Joaquin Fairgrounds
Commons or Lunch Area
Finding: There are no compliant accessible seating areas.

Alternative *
Rec:
(Where
Available)

Winner's Gaming and Sports Emporium

Full Rec Provide compliant accessible wheelchair seating that will Citation CBC 1122B.3; ADAAG 4.32.2; ADAAG 4.32.5(2)
provide viewing positions with a line of sight comparable to
those of the general public (see ADAAG 4.1.3(19) and ADAAG
4.33.2). At least one companion fixed seat complying with Minimum Quantity 1
ADAAG 4.33.3 should be provided next to each wheelchair Maximum Quantity: 1
seating space. Readily removable seats may be installed in
wheelchair spaces when the spaces are not required to Unit: Each
accommodate wheelchair users (see CBC 1104B.3.7 and Minimum Estimated Cost: 237
ADAAG 4.1.3(19). Where total seating capacity exceeds 300,
accessible wheelchair seating spaces shall be provided in more Maximum Estimated Cost: 237
than one location (see CBC 1104B.3.5 and ADAAG 4.33.3.) . Record Number 1169
Each accessible seat shall be marked as accessible. Priority:

Assembly Areas
Finding: There is no compliant wheelchair seating at the Speedway
bleachers.

Alternative *
Rec:
(Where
Available)

Delta Speedway

Full Rec Provide compliant accessible wheelchair seating that will Citation CBC 1104B.4; ADAAG 4.33
provide viewing positions with a line of sight comparable to
those of the general public (see ADAAG 4.1.3(19) and ADAAG
4.33.2). At least one companion fixed seat complying with Minimum Quantity 1
ADAAG 4.33.3 should be provided next to each wheelchair Maximum Quantity: 1
seating space. Readily removable seats may be installed in
wheelchair spaces when the spaces are not required to Unit: Each
accommodate wheelchair users (see CBC 1104B.3.7 and Minimum Estimated Cost: 237
ADAAG 4.1.3(19). Where total seating capacity exceeds 300,
accessible wheelchair seating spaces shall be provided in more Maximum Estimated Cost: 237
than one location (see CBC 1104B.3.5 and ADAAG 4.33.3.) . Record Number 1180
Each accessible seat shall be marked as accessible. Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 528 of 542


Facility Name: San Joaquin Fairgrounds
Locker Rooms
Finding: The width of the benches in each locker room is less then 24
inches. The length of the benches in each locker room is less
then 48 inches. The height of the benches in each locker room
is greater than 19 inches.

Alternative *
Rec:
(Where
Available)

Jockey's Quarters

Full Rec Install at least one bench with dimensions of 24 inches in width Citation ADAAG 4.35.4
by 48 inches in length fixed to the wall along the longer
dimension in each locker room. Mount the bench 17 inches to
19 inches above the finished floor with ADAAG 4.35.4 in each Minimum Quantity 1
locker room. Provide sufficient clear floor space alongside the Maximum Quantity: 1
bench to allow a person using a wheelchair to make a parallel
transfer onto the bench. Unit: Each
Minimum Estimated Cost: 500
Maximum Estimated Cost: 500
Record Number 1198
Priority:

Locker Rooms
Finding: The height of the coat hooks in the locker room is greater than
54 inches above the floor surface.

Alternative *
Rec:
(Where
Available)

Jockey's Quarters

Full Rec Remount the coat hooks to a maximum height of 54 inches Citation CBC 1115B.9.2; ADAAG A4.27
above the floor surface.

Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 1199
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 529 of 542


Facility Name: San Joaquin Fairgrounds
Locker Rooms
Finding: Showers are provided, there are no accessible showers in the
Jockey's Quarters.

Alternative *
Rec:
(Where
Available)

Jockey's Quarters

Full Rec Since open showers are provided in the locker room, at least Citation CBC 1115B.6.3; ADAAG 4.21
one accessible shower is required. Install an accessible shower
in one of the corners with L-shaped grab bars extending along
the two walls with a folding seat adjacent to the shower controls Minimum Quantity 1
in the locker room (see CBC 1115B.6.3 and ADAAG 4.21). Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 3260
Maximum Estimated Cost: 3260
Record Number 1204
Priority:

Locker Rooms
Finding: This sauna is not accessible and cannot be easily altered.
There is not sufficient clear floor space in the sauna to
accommodate an individual in a wheelchair.

Alternative *
Rec:
(Where
Available)

Sauna in the Jockey's Quarters

Full Rec Consult a design professional to modify the sauna. One or Citation CBC 1115B.7.2; ADAAG 4.16.2
more walls may need to be moved to provide sufficient clear
floor space to inscribe a 60-inch diameter turning radius in the
sauna to accommodate an individual in a wheelchair. Minimum Quantity 1
Maximum Quantity: 1
Unit: Custom
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 1203
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 530 of 542


Facility Name: San Joaquin Fairgrounds
Locker Rooms
Finding: The soap dish is mounted at a height greater than 40 inches
above the shower floor.

Alternative *
Rec:
(Where
Available)

Women's Restroom at Horse Barn 3

Full Rec Relocate the soap dish mounted in the shower compartment Citation CBC 1115B.6.2.4.6
designated to be accessible in the restroom so that it is
mounted on the same wall as the water controls at a maximum
height of 40 inches above the shower floor (see CBC Minimum Quantity 1
1115B.6.2.4.6). Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 277
Maximum Estimated Cost: 277
Record Number 1202
Priority:

Outdoor Sports Areas and Playgrounds


Finding: The surface under the bleachers is asphalt. No wheelchair
seating is provided next to the bleachers.

Alternative *
Rec:
(Where
Available)

Bleachers Between L-2 and L-3

Full Rec Provide accessible wheelchair seating areas adjacent to the Citation CBC 1104B.4; ADAAG 4.33
bleachers with equivalent line of sight as provided to members
of the general public, if technically feasible; otherwise provide
accessible wheelchair seating areas adjacent to the bleachers Minimum Quantity 1
where unobstructed sight lines can be provided (see CBC Maximum Quantity: 1
1104B.4 and ADAAG 4.33.3). The wheelchair seating area
should be outlined, and have the International Symbol of Unit: Each
Accessibility to reserve it for wheelchair users. Minimum Estimated Cost: 237
Maximum Estimated Cost: 237
Record Number 1187
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 531 of 542


Facility Name: San Joaquin Fairgrounds
Outdoor Sports Areas and Playgrounds
Finding: The surface under the bleachers is asphalt. No wheelchair
seating is provided next to the bleachers.

Alternative *
Rec:
(Where
Available)

Bleachers Next to L-1

Full Rec Provide accessible wheelchair seating areas adjacent to the Citation CBC 1104B.4; ADAAG 4.33
bleachers with equivalent line of sight as provided to members
of the general public, if technically feasible; otherwise provide
accessible wheelchair seating areas adjacent to the bleachers Minimum Quantity 1
where unobstructed sight lines can be provided (see CBC Maximum Quantity: 1
1104B.4 and ADAAG 4.33.3). The wheelchair seating area
should be outlined, and have the International Symbol of Unit: Each
Accessibility to reserve it for wheelchair users. Minimum Estimated Cost: 237
Maximum Estimated Cost: 237
Record Number 1194
Priority:

Outdoor Sports Areas and Playgrounds


Finding: There is no signage at the ticket counter indicating the
availability of accessible seating.

Alternative *
Rec:
(Where
Available)

Bleachers Next to L-1

Full Rec Post signage at the ticket counter indicating the availability and Citation CBC 1104B.3.4.1; ADAAG 4.1.3(19)
location of accessible seating areas (see CBC 1104B.3.4.1).

Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 107
Maximum Estimated Cost: 107
Record Number 1195
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 532 of 542


Facility Name: San Joaquin Fairgrounds
Outdoor Sports Areas and Playgrounds
Finding: The surface under the bleachers is asphalt. No wheelchair
seating is provided next to the bleachers.

Alternative *
Rec:
(Where
Available)

Bleachers South of L-5

Full Rec Provide accessible wheelchair seating areas adjacent to the Citation CBC 1104B.4; ADAAG 4.33
bleachers with equivalent line of sight as provided to members
of the general public, if technically feasible; otherwise provide
accessible wheelchair seating areas adjacent to the bleachers Minimum Quantity 1
where unobstructed sight lines can be provided (see CBC Maximum Quantity: 1
1104B.4 and ADAAG 4.33.3). The wheelchair seating area
should be outlined, and have the International Symbol of Unit: Each
Accessibility to reserve it for wheelchair users. Minimum Estimated Cost: 237
Maximum Estimated Cost: 237
Record Number 1192
Priority:

Outdoor Sports Areas and Playgrounds


Finding: There is no signage at the ticket counter at L-5 indicating the
availability of accessible seating.

Alternative *
Rec:
(Where
Available)

Bleachers South of L-5

Full Rec Post signage at the ticket counter indicating the availability and Citation CBC 1104B.3.4.1; ADAAG 4.1.3(19)
location of accessible seating areas (see CBC 1104B.3.4.1).

Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 107
Maximum Estimated Cost: 107
Record Number 1193
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 533 of 542


Facility Name: San Joaquin Fairgrounds
Outdoor Sports Areas and Playgrounds
Finding: There is no signage at the ticket counter at the Delta Speedway
or the Grandstands indicating the availability of accessible
seating.

Alternative *
Rec:
(Where
Available)

Delta Speedway

Full Rec Post signage at each ticket counter indicating the availability Citation CBC 1104B.3.4.1; ADAAG 4.1.3(19)
and location of accessible seating areas (see CBC 1104B.3.4.1).

Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 107
Maximum Estimated Cost: 107
Record Number 1179
Priority:

Outdoor Sports Areas and Playgrounds


Finding: The height of the concession counter at the east end of the
Delta Speedway is greater than 36 inches.

Alternative *
Rec:
(Where
Available)

Delta Speedway

Full Rec Lower the concession counter to a height between 28 inches Citation ADAAG 7.2
and 36 inches above the ground level (see ADAAG 7.2).

Minimum Quantity 1
Maximum Quantity: 1
Unit: 3 Linear Feet
Minimum Estimated Cost: 129
Maximum Estimated Cost: 129
Record Number 1181
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 534 of 542


Facility Name: San Joaquin Fairgrounds
Outdoor Sports Areas and Playgrounds
Finding: The height of the ticket counter at the west end of the Delta
Speedway is greater than 36 inches. The counter is a
protruding object.

Alternative *
Rec:
(Where
Available)

Delta Speedway

Full Rec Lower the ticket counter to a height no greater than 36 inches Citation ADAAG 7.2
above the floor/ground (see ADAAG 7.2).

Minimum Quantity 1
Maximum Quantity: 1
Unit: 3 Linear Feet
Minimum Estimated Cost: 129
Maximum Estimated Cost: 129
Record Number 1182
Priority:

Outdoor Sports Areas and Playgrounds


Finding: The press box above the stadium is stair-access only and is not
accessible to individuals with mobility impairments.

Alternative There are ways to provide access to the programs, services and
Rec: activities at the press box without installing accessible vertical
(Where means to the press box area, to include electronic relay devices
Available) with electronic visual components (video camera or television)
that offer the equivalent sight line provided from inside the press
box. The electronic relays may be cabled to an accessible
location where individuals with mobility impairments can access. Delta Speedway

Full Rec In most instances, press boxes are built and used by volunteers Citation
and the public, which mandates that access for individuals with
disabilities be provided. This is difficult in most situations with
the location of the press box usually located high above the Minimum Quantity 1
assembly area. Vertical access may include installing an Maximum Quantity: 1
exterior enclosed platform lift or installing an equivalent press
box at ground level with electronic relay devices and equipment Unit: Custom
that would provide the same line of sight viewing capability as Minimum Estimated Cost: 0
that in the elevated press box.
Maximum Estimated Cost: 0
Record Number 1208
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 535 of 542


Facility Name: San Joaquin Fairgrounds
Outdoor Sports Areas and Playgrounds
Finding: The height of the ticket counter at the entrance to the
Grandstands is greater than 36 inches.

Alternative *
Rec:
(Where
Available)

Grandstands

Full Rec Lower the ticket counter to a height no greater than 36 inches Citation ADAAG 7.2
above the floor/ground (see ADAAG 7.2).

Minimum Quantity 1
Maximum Quantity: 1
Unit: 3 Linear Feet
Minimum Estimated Cost: 129
Maximum Estimated Cost: 129
Record Number 1184
Priority:

Outdoor Sports Areas and Playgrounds


Finding: The press box above the stadium is stair-access only and is not
accessible to individuals with mobility impairments.

Alternative There are ways to provide access to the programs, services and
Rec: activities at the press box without installing accessible vertical
(Where means to the press box area, to include electronic relay devices
Available) with electronic visual components (video camera or television)
that offer the equivalent sight line provided from inside the press
box. The electronic relays may be cabled to an accessible
location where individuals with mobility impairments can access. Grandstands

Full Rec In most instances, press boxes are built and used by volunteers Citation
and the public, which mandates that access for individuals with
disabilities be provided. This is difficult in most situations with
the location of the press box usually located high above the Minimum Quantity 1
assembly area. Vertical access may include installing an Maximum Quantity: 1
exterior enclosed platform lift or installing an equivalent press
box at ground level with electronic relay devices and equipment Unit: Custom
that would provide the same line of sight viewing capability as Minimum Estimated Cost: 0
that in the elevated press box.
Maximum Estimated Cost: 0
Record Number 1196
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 536 of 542


Facility Name: San Joaquin Fairgrounds
Outdoor Sports Areas and Playgrounds
Finding: There is no compliant accessable seating areas at the
Grandstand Bleachers.

Alternative *
Rec:
(Where
Available)

Grandstands

Full Rec Provide compliant accessible wheelchair seating that will Citation CBC 1104B.3.4.1; ADAAG 4.1.3(19)
provide viewing positions with a line of sight comparable to
those of the general public (see ADAAG 4.1.3(19) and ADAAG
4.33.2). At least one companion fixed seat complying with Minimum Quantity 1
ADAAG 4.33.3 should be provided next to each wheelchair Maximum Quantity: 1
seating space. Readily removable seats may be installed in
wheelchair spaces when the spaces are not required to Unit: Each
accommodate wheelchair users (see CBC 1104B.3.7 and Minimum Estimated Cost: 237
ADAAG 4.1.3(19). Where total seating capacity exceeds 300,
accessible wheelchair seating spaces shall be provided in more Maximum Estimated Cost: 237
than one location (see CBC 1104B.3.5 and ADAAG 4.33.3.) . Record Number 1197
Each accessible seat shall be marked as accessible. Priority:

Outdoor Sports Areas and Playgrounds


Finding: There is stair access only to the bleachers. The surface under
the bleachers is concrete. No wheelchair seating is provided
next to the bleachers.

Alternative *
Rec:
(Where
Available)

L-1

Full Rec Provide accessible wheelchair seating areas adjacent to the Citation CBC 1104B.4; ADAAG 4.33
bleachers with equivalent line of sight as provided to members
of the general public, if technically feasible; otherwise provide
accessible wheelchair seating areas adjacent to the bleachers Minimum Quantity 1
where unobstructed sight lines can be provided (see CBC Maximum Quantity: 1
1104B.4 and ADAAG 4.33.3). The wheelchair seating area
should be outlined, and have the International Symbol of Unit: Each
Accessibility to reserve it for wheelchair users. Minimum Estimated Cost: 237
Maximum Estimated Cost: 237
Record Number 1188
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 537 of 542


Facility Name: San Joaquin Fairgrounds
Outdoor Sports Areas and Playgrounds
Finding: There is no signage at the ticket counter at L-1 indicating the
availability of accessible seating.

Alternative *
Rec:
(Where
Available)

L-1

Full Rec Post signage at the ticket counter indicating the availability and Citation CBC 1104B.3.4.1; ADAAG 4.1.3(19)
location of accessible seating areas (see CBC 1104B.3.4.1).

Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 107
Maximum Estimated Cost: 107
Record Number 1189
Priority:

Outdoor Sports Areas and Playgrounds


Finding: The surface under the bleachers is concrete. No wheelchair
seating is provided next to the bleachers.

Alternative *
Rec:
(Where
Available)

L-3

Full Rec Provide accessible wheelchair seating areas adjacent to the Citation CBC 1104B.4; ADAAG 4.33
bleachers with equivalent line of sight as provided to members
of the general public, if technically feasible; otherwise provide
accessible wheelchair seating areas adjacent to the bleachers Minimum Quantity 1
where unobstructed sight lines can be provided (see CBC Maximum Quantity: 1
1104B.4 and ADAAG 4.33.3). The wheelchair seating area
should be outlined, and have the International Symbol of Unit: Each
Accessibility to reserve it for wheelchair users. Minimum Estimated Cost: 237
Maximum Estimated Cost: 237
Record Number 1185
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 538 of 542


Facility Name: San Joaquin Fairgrounds
Outdoor Sports Areas and Playgrounds
Finding: There is no signage at the ticket counter at L-3 indicating the
availability of accessible seating.

Alternative *
Rec:
(Where
Available)

L-3

Full Rec Post signage at the ticket counter indicating the availability and Citation CBC 1104B.3.4.1; ADAAG 4.1.3(19)
location of accessible seating areas (see CBC 1104B.3.4.1).

Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 107
Maximum Estimated Cost: 107
Record Number 1186
Priority:

Outdoor Sports Areas and Playgrounds


Finding: The grass surface of the soccer field at the facility prevents
access to individuals with mobility impairments.

Alternative *
Rec:
(Where
Available)

Soccer Field

Full Rec Provide an accessible route to the soccer field area where Citation CBC 1104B.1.2; CBC 1124B.1; ADAAG 4.33
programs, services and activities are provided. The minimum
width of the path of travel is 48 inches with 60 inch by 60 inch
passing spaces provided every 200 feet. No protruding objects Minimum Quantity 1
are permitted on the accessible path of travel. Accessible Maximum Quantity: 1
surfaces shall be firm, stable and slip resistant.
Unit: 30 Linear Feet
Minimum Estimated Cost: 360
Maximum Estimated Cost: 360
Record Number 1205
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 539 of 542


Facility Name: San Joaquin Fairgrounds
Outdoor Sports Areas and Playgrounds
Finding: There is stair access only to the bleachers. The surface under
the bleachers is asphalt. No wheelchair seating is provided next
to the bleachers.

Alternative *
Rec:
(Where
Available)

Stockton Motorplex

Full Rec Provide accessible wheelchair seating areas adjacent to the Citation CBC 1104B.4; ADAAG 4.33
bleachers with equivalent line of sight as provided to members
of the general public, if technically feasible; otherwise provide
accessible wheelchair seating areas adjacent to the bleachers Minimum Quantity 1
where unobstructed sight lines can be provided (see CBC Maximum Quantity: 1
1104B.4 and ADAAG 4.33.3). The wheelchair seating area
should be outlined, and have the International Symbol of Unit: Each
Accessibility to reserve it for wheelchair users. Minimum Estimated Cost: 237
Maximum Estimated Cost: 237
Record Number 1190
Priority:

Outdoor Sports Areas and Playgrounds


Finding: There is no signage at the ticket counter at the Stockton
Motorplex indicating the availability of accessible seating.

Alternative *
Rec:
(Where
Available)

Stockton Motorplex

Full Rec Post signage at the ticket counter indicating the availability and Citation CBC 1104B.3.4.1; ADAAG 4.1.3(19)
location of accessible seating areas (see CBC 1104B.3.4.1).

Minimum Quantity 1
Maximum Quantity: 1
Unit: Each
Minimum Estimated Cost: 107
Maximum Estimated Cost: 107
Record Number 1191
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 540 of 542


Facility Name: San Joaquin Fairgrounds
Outdoor Sports Areas and Playgrounds
Finding: The height of the ticket counter next to Buildings 2 and 3 is
greater than 36 inches.

Alternative *
Rec:
(Where
Available)

Ticket Counter Next to Buildings 2 and 3

Full Rec Lower the ticket counter to a height no greater than 36 inches Citation ADAAG 7.2
above the floor/ground (see ADAAG 7.2).

Minimum Quantity 1
Maximum Quantity: 1
Unit: 3 Linear Feet
Minimum Estimated Cost: 129
Maximum Estimated Cost: 129
Record Number 1183
Priority:

Emergency Warning Systems


Finding: The facility shall have a fire and life safety emergency plan that
specifically addresses the evacuation of individuals with
disabilities.

Alternative *
Rec:
(Where
Available)

Full Rec A fire and life safety emergency plan that specifically addresses Citation CFC Part 9 & CBC 1114B.2
the evacuation of individuals with disabilities must comply with
CFC Part 9 and CBC 1114B.2 for areas of rescue assistance.
Minimum Quantity 1
Maximum Quantity: 1
Unit: None Selected
Minimum Estimated Cost: 0
Maximum Estimated Cost: 0
Record Number 1206
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 541 of 542


Facility Name: San Joaquin Fairgrounds
Emergency Warning Systems
Finding: There are visual warning devices in the Winners Gaming and
Sports Emporium, though no visual warning devices are located
elsewhere in the facility.

Alternative Altering a facility's programs, or addressing higher priority


Rec: barriers can reduce or eliminate the need for an area of rescue
(Where assistance, such as making certain that an individual with a
Available) disability participates in programs located near an already
accessible exit. Otherwise creating an accessible exit can
provide an acceptable alternative to providing an area of rescue
assistance.

Full Rec Install visual warning devices integrated with the facility's alarm Citation CBC 1114B.2.4; ADAAG 4.1.3(14); ADAAG 4.28
system complying with CBC 1114B.2.5, ADAAG 4.1.3(14) and
ADAAG 4.28 throughout the facility.
Minimum Quantity 1
Maximum Quantity: 1
Unit: None Selected
Minimum Estimated Cost: 0
Maximum Estimated Cost: 288
Record Number 1207
Priority:

Disability Access Consultants, Inc. (800) 743-7067 Page 542 of 542

You might also like