Introduction
ZXDU68 T601 is a high-efficiency DC power system developed by ZTE. The full capacity of standard configuration is 600A, which can be extended to 1800A for one cabinet if requested. This system is smart and green with a diversity of interfaces, including dry contract, RJ45, RS232, RS485, USB, for flexible networking as per application scenarios. The peak efficiency of the system is up to 96%, which saves more power and emits less CO2. The power density is higher. The depth of the cabinet is only 400mm and the front access design further reduces area occupation and space for maintenance. The monitoring unit of the system adopts color screen with better visual effects and user-friendly multi-screen design to ease the operation.

Extensive network interfaces to fulfill the more flexible networking ways: input/output dry contacts, RJ45, RS232, RS485, USB, which can meet the requirements of TelnetHTTPFTP and SNMP networking, so that to save the networking cost. Using USB in terface to expand monitoring memory unlimitedly and ease the installation by setting the initial parameter of the power system. Wide range of input voltage: 80~300Vac, stronger adaptability to the power grid to reduce the use of battery and then lengthen the battery life. Wide temperature tolerance: -40~+70C, more field adaptable, saving temperature control equipment.

Application Key features


2G/3G/4G Wireless access station, Microwave repeat station Satellite station Optical transmission equipment Small or middle size switch centre

High efficiency, saving electricity: System peak efficiency is up to 96%, with the hibernation function of the system along, can save energy by 4%~10% compared to the traditional power supply system. High power density, saving occupied space and rental: 1U height can realize the current output of 200A. System depth is 400mm with front access design, which could save the occupied space by more than 50%. Digital design (control), more stable performance: Using DSP control to improve system reliability. Connecting the monitoring unit and the modules with CAN bus to achieve faster transmission speed, more timely data and fewer faults.

www.zte.com.cn
System Technical Specifications
parameters AC Input Nominal input rate Input range Frequency Power factor Total Harmonic Distortion(THD) DC Output Output voltage Output current Efficiency Protection Environment requirement Operating temperature Storage temperature Relative humidity Dimensions and weight Dimensions Weight 1600mmH*600mmW*400mmD < 100kg(600A system) -40C~+70C -40C~+85C 0~95% -48VDC nominally; operating range: -42~-58VDC 1U/200A, Maximum up to 600Astandard 95%(rated input; full load) OCP, OVP, UVP, OTP 380 Vac three-phase 220 Vac single-phase 80300Vac 45~66Hz >0.99 at 50% load and more <5% from 50 to 100% of full load Description

CSU Basic Specification


parameters Model Display Communication interface CAN Nodes Remote control protocol Multi-Language Logging records Monitoring I/O Power Consumption Dimension Description ZXDU-CSU500A Color screen128*128 Friendly style box RJ45,CAN,RS232,RS485,USB Up to 80 PSUs SNMP, FTP, HTTP, Telnet English, Chinese, Spanish, French, Dutch, Russian, and others required Up to 10,000 history logs 4 default dry contact input 4 programmable input 8 dry contacts output Less than 6W 132*41*290mm(W*H*D)

For continuous improvement and development, the specifications are subject to change without prior notice.

No. 55, Hi-tech Road South, ShenZhen, P.R.China Postcode: 518057 Website: www.zte.com.cn Tel: +86-755-26770000 Fax: +86-755-26771999