Aftermarket Solutions, Ref. No. [219]

11-1

Communication Systems

Contents
Description Communication Systems Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PowerNet General Description. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Electrical Services & Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Flexible Network Architecture . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PowerNet Software Suite . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product History . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IMPACC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Product History Time Line . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Technology Upgrades . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Communication Hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PONI, IPONI/BPONI, EPONI/EPONIF, WEBPONI . . . . . . . . . . . . . . . . . . CONI Card . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MINT II . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Johnson Metering Interface (JMI) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Analog Input Module (AIM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Addressable Relay II (ARII) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IMPCABLE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NetLink . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Contact Input Card (CIC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Further Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pricing Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page 11-2 11-2 11-3 11-3 11-4 11-6 11-6 11-6 11-7 11-14 11-14 11-14 11-14 11-15 11-15 11-15 11-15 11-16 11-16 11-16 11-17 11-17

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
PowerNet

25

CA08105001E

For more information visit: www.EatonElectrical.com

11-2

Communication Systems Electrical Aftermarket Products and Services


March 2006

Overview

Aftermarket Solutions, Ref. No. [220]

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25

Product Description
Cutler-Hammer PowerNet
Applications
Energy management. Power quality. Reliability and uptime management. Information systems integration.

Energy Management
The PowerNet system is the keystone of a successful energy management program. It can provide data to verify the energy bill for the site, allocate the cost to individual users, identify potential energy saving opportunities through submetering and load proling, and provide the information necessary to construct and implement an energy strategy in the deregulated environment. PowerNet data can be delivered to desktop PCs throughout the facility, enabling energy users to be active participants in managing energy costs. With PowerNet, facilities have lowered energy costs by reducing consumption, identifying and modifying usage patterns, negotiating more attractive utility rate structures, and allocating costs to departments or processes.

Information and Systems Integration


A PowerNet system ensures that the right information is available to anyone on- or off-site to make an informed decision. It combines the above mentioned energy management, power quality and system uptime information with the software tools to turn that data into information that can help you manage your business more effectively. The information can be made available at the plant site, at headquarters or at a key consultant or service provider anywhere it is needed and the expertise to use it is available. The system brings the problem to the expert, instead of requiring the expert to go to the problem signicantly improving productivity. All this using standard, open, Windows-based software, utilizing open Ethernet TCP/IP architecture, substantially reducing the cost of implementing the PowerNet system.

Metered/Monitored Devices

IQ meters. Protective relays. Trip units. Motor starters. Overload relays. Transfer switches. Network protectors. I/O modules. Support for multiple vendor integration.

Power Quality
The PowerNet system helps to ensure optimal electrical power quality, an increasingly important consideration with the continued growth of nonlinear loads and increasingly sensitive production and ofce equipment. Poor power quality can result in expensive downtime and costly equipment failures. The PowerNet system provides real-time data and alarms as well as historical proles to isolate the source, magnitude, time and direction of power quality problems, including voltage disturbances, harmonics and power factor.

Communications
Ethernet-based. Dedicated twisted shielded pair. Dial-up. Radio frequency.

Architecture
Flexibility is a key feature of the PowerNet open design network. Multiple users and vendors may use the same PowerNet network, eliminating the need for a proprietary network dedicated to a single vendor. In addition, power management data can be shared across the facility or across the world via the World Wide Web. The high-speed Ethernet architecture of PowerNet is the same architecture that moves gigabits of data to millions of Internet and e-mail users.

Software Modules
Monitor and control. Graphical display. Energy billing. Waveform display.

PowerNet General Description


The Cutler-Hammer PowerNet system from Eatons electrical business is designed to manage the power distribution system. This integrated power management system is the ideal tool to help manage energy costs, troubleshoot power quality problems, and ensure the reliability and integrity of the electrical distribution system. It is well suited for application in a manufacturing facility, a process-oriented plant, a commercial ofce building, a utility generating plant and a multi-building campus. The PowerNet system consists of PowerNet software networked with Cutler-Hammer products of unparalleled breadth, accuracy and reliability: meters, relays, trip units, motor protectors, starters and transfer switch controllers I/O devices, thus forming the most comprehensive power management system solution in the industry. In addition, the extensive library of third-party interfaces makes PowerNet uniquely qualied to be the single solution for an existing or new application.

Reliability and Uptime


The PowerNet system provides crucial electrical distribution system information to ensure power system uptime. It provides alarms warning of protective trips, potential equipment maintenance requirements, detailed trip diagnostic data, and other troubleshooting data essential to reliable operation. Use of this data can eliminate unnecessary trips and isolate a fault to ensure minimum downtime, thus minimizing lost revenue and prots. The remote conguration and data-gathering feature of PowerNet reduces labor costs, recording errors and potential miscoordination.

IMPACC/PowerNet Compatibility
PowerNet is backward compatible with existing IMPACC or PowerNet systems on a dedicated network or twisted pair network.

For more information visit: www.EatonElectrical.com

CA08105001E

Communication Systems Electrical Aftermarket Products and Services


March 2006
Aftermarket Solutions, Ref. No. [221]

11-3

Overview

Product Description (Continued)


Electrical Services & Systems

Flexible Network Architecture


A PowerNet network can be built in a variety of congurations. Systems can be built using existing Ethernet networks as the backbone, as well as on a dedicated twisted shielded pair running throughout a facility. Telephone, radio and ber modems can be used to create networks where it is cost prohibitive to run dedicated cables. The most exible, highest performance network architecture includes a dedicated twisted shielded pair network within the switchboard or equipment room connecting into a high speed Ethernet backbone. For a layout of a typical facility network, refer to the Electrical Consulting Application Guide.

Dedicated Twisted Shielded Pair


Customers who desire to run a dedicated network for the power monitoring network have a choice between a dedicated Ethernet network or running a twisted shielded pair. A network of 1000 devices running up to 10,000 feet can be networked through one twisted shielded pair of wire.

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

Existing Network Media


When creating a network in an existing facility, it may not be economical to run a dedicated twisted shielded pair and Ethernet may not be available. In this case, line drivers are used to route communications across existing networks other than Ethernet. Line drivers allow the use of telephone lines, ber and radio transmitters for wireless communications.

34455002

Ethernet Backbone
PowerNet Software

Supplementing the hardware and software, Eaton - Electrical Services & Systems can provide local startup and integration services to customize the PowerNet system to your specic business needs. Basic eld startup, integration of PowerNet into other plant systems, and remote monitoring of the plant with industry experts in energy and power quality are all services provided by our local eld representatives. These services will ensure that you get maximum return on all of your system investments.
Note: PowerNet systems do not consist of exclusively Cutler-Hammer products. Hundreds of drivers exist to communicate with many vendors meters, protective relays and PLCs.

TCP/IP Ethernet networks have become the worldwide standard for moving information. Industry has recognized Ethernet as a high speed, exible, low-cost network that is not vendor dependent. The PowerNet network utilizes a standard TCP/IP Ethernet as the high speed backbone for carrying information to clients across the plant or across the world. The products designed for interfacing directly to a TCP/IP Ethernet network are the Ethernet PONI and WEBPONI designed for a single device, and a NetLink or EMINT designed to connect multiple devices to an Ethernet backbone.

Load Interrupter Switchgear Transformer

Medium Voltage Unit Substation

Medium Voltage Starter

Personal Computer with Cutler-Hammer PowerNet Software

Power Quality Metering Data Energy Information Switch/Breaker Starter Status/Control Time Stamped Events Breaker Operations Motor Runtime Motor Winding/Bearing Temperature Trip Curve Monitoring/Configuration Transformer Data

17 18 19

Load Interrupter Switchgear Transformer

Low Voltage Secondary Unit Substation

Power Quality Metering Data Energy Information Starter/Breaker Status/Control Time Stamped Events Breaker Operations Trip Curve Monitoring/Configuration

20 21 22 23 24 25

Low Voltage Switchboard

Lighting Control Panelboard

Motor Control Center

Adjustable Frequency Control

Power Quality Metering Data Energy Information Starter/Breaker Status/Control Time Stamped Events Breaker Operations Motor Operations Runtime Trip Curve Monitoring/Configuration Drive Status Drive Metering Data Drive Speed Adjustment/Control

Figure 11-1. Cutler-Hammer PowerNet System


CA08105001E For more information visit: www.EatonElectrical.com

11-4

Communication Systems Electrical Aftermarket Products and Services


March 2006

PowerNet Communications

Aftermarket Solutions, Ref. No. [222]

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25

Product Description (Continued)


PowerNet Software Suite
Connectivity Facility Monitoring Power Quality Energy Management
The Cutler-Hammer PowerNet software suite is a family of software applications, client/server conguration, that help provide a window into an electrical distribution system. Monitoring and controlling capabilities are included in a single CD installation on any Windows NT, 98, 2000 or XP and above operating systems.

Facility Monitoring Bundle

The Power Quality Bundle includes the following functions: Viewing of captured waveforms. Up to eight cycles of actual waveform. Zoomed-in view of high-speed waveform samples. Spectrum chart showing frequency content and magnitude (Fourier analysis).

Screen Shot

Connectivity Bundle
The Connectivity collection of software functionality opens the doors to an electrical distribution system by providing the foundation for communications with metering, relaying, multifunctional trip units, and input/output devices. The Connectivity Bundle supports up to 1000 devices, enabling communications on a TCP/IP network, providing the PowerNet client applications with real-time data, device event information, device waveforms, historical data and many other features. The Connectivity Bundle stores its data in an MSDE/SQL database for maximum data security and reliability. The Connectivity Bundle includes the following functions:

Building on the foundation that the Connectivity Bundle provides, the Facility Monitoring Bundle provides realtime data, historical trended data, and alarming information that is required to ensure maximum uptime and reliability, as well as efcient panel loading and proper maintenance activity. The Facility Monitoring Bundle enables the following functions:

Event Viewer Software

Communications to 5, 10, 34, 100, 200 and 1000 devices. Auto learn of all connected devices for maximum usability. Security conguration. Trending/logging congurations. Devices set point editing/printing/ viewing. MSDE/SQL data storage. Dynamic Data Exchange (DDE) Server. OLE for Process Control (OPC) Server. Modbus Server. SES92 Gateway communications.

Real-time data display in spreadsheet format with drag and drop experience. Alarm annunciation and viewing with complete traceability. OPC and DDE connectivity solutions for remote client PC installations. Drag and drop conguration. Multiple views/customization. ActiveX monitor and control screens for all congured devices.

CBEMA/ITIC representation of events. Top down access to specic waveform events from event lists and CBEMA/ITIC curves.

Power Quality Bundle


For the engineer, the PowerNet Power Quality Bundle includes the functionality that engineers need to analyze events, determine root causes, or perform accurate power quality studies for electrical distribution systems. Table 11-1. Captured Waveforms
Currents Cutler-Hammer Device IQ Digitrip MPCV Analyzer 910 1150 OPTIM Relay 1050 Phase A Phase B Phase C Neutral Ground

PowerNet Set Points and Trip Curves

For optimum performance, maximum reliability and exibility, the PowerNet Connectivity Bundle ts the bill.

Trip curve display for coordination and selectivity needs. Log-log coordination curve plotted on-screen for trip units and motor protective relays with the click of a button. Online modication of trip curve pickups and time delays; instant verication of coordination with an updated trip curve. Automatic scale adjustment based on device pickup level. Addition or removal of trip curves directly from the display screen. Color-coded curves tied to the device description for added clarity. Overlay multiple curves. View motor start proles next to motor protection relay trip curve.

For more information visit: www.EatonElectrical.com

CA08105001E

Communication Systems Electrical Aftermarket Products and Services


March 2006
Aftermarket Solutions, Ref. No. [223]

11-5

PowerNet Communications

Product Description (Continued)


PowerNet Bill
The PowerNet software suite maximizes the usefulness of the stored data collected by the PowerNet system with a bundle of tools that generate trends of energy data and reports for cost allocation or billing for energy usage. The PowerNet Bill bundle provides the following functions:

1 2 3 4 5 6 7 8 9 10 11 12
Figure 11-2. Typical Tenant Bill

Support for electrical energy, as well as gas, water or any other utility that can be measured by the Digital Input Module. Accurate coincident peak demand calculations by patented broadcast capabilities. Time-of-day allocation. Holiday and weekend charges. Common usage allocation. DDE data billing.

13 14 15

Energy Trending of Multiple Metering

Energy trending. Automatically schedules generation of trends. Trending of individual meters and energy users. Zoom and pan for detailed analysis. Target ags for quick wasteful practice identication.

16 17 18 19 20 21 22
Figure 11-3. Typical Industrial User Report
Note: ICONICS is only offered through your local E-ESS ofce.

23 24 25

CA08105001E

For more information visit: www.EatonElectrical.com

11-6

Communication Systems Electrical Aftermarket Products and Services


March 2006

IMPACC

Aftermarket Solutions, Ref. No. [224]

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25

Product History
IMPACC
The Integrated Monitoring Protection and Control Communications (IMPACC) product line emerged in 1987 with the introduction of the rst microprocessorbased multifunctional meter, the IQ Data Plus. The IQ Data Plus set the standard for a new class of intelligent meters which offered modular communication capability. The rst modular communication card, the Product Operated Network Interface (PONI), targeted the noisy environment associated with electrical distribution equipment. The introduction of the PONI card provided the ability to daisy chain a thousand devices back to a computer and view and/or trend all points. In 1988, Westinghouse offered IMPACC Series III software, the rst Microsoft Windows compatible electrical distribution monitoring package. Since this time, the electronic communication and computer industry has evolved and grown with many improvements and developments in the microprocessor applications and speed. Many new communicating hardware devices have been added to the product line and can be found in Motor Control Centers (MCCs), low and medium voltage switchgear assemblies, switchboards and transfer switches. All this equipment can be connected to one main computer via your typical twisted-shielded-pair copper conductors or the latest and greatest in Ethernet connectivity options that include 10Base-T or Fiber.

The Cutler-Hammer offering after the 1995 time frame included three new software programs which worked in conjunction with IMPACC Series III . These applications enabled analysis of harmonics, online coordination of electrical equipment and electronic billing based on actual electrical usage and utility rate structures. In 1999, the Cutler-Hammer offering took a turn from the single-station stand-alone computer application to a backbone that has been gaining popularity in leaps and bounds due to the proliferation of the Internet. The PowerNet software suite was introduced as a networked solution suite that utilizes the Ethernet Local Area Network technology. The single-station solution and days of bringing the engineer to the data were drastically changed with the concept of sharing data over Ethernet installations bringing the data to the specialist. The software application solutions available since this time are

portable and exible such that the energy analyst need only install those client applications that directly apply to the daily functions of the energy analyst. Waveform, Trip Curve, Energy Billing, Event Viewer, Trending, Monitoring and Modbus Server software applications are a few of the client applications that can be installed on any computer on the Local and Wide Area Network accessing all installed metering, relaying and control devices on the network. The PowerNet software makes it possible to communicate with each and every IQ and PowerNet product that has been placed in service since 1987. Modbus, Ethernet, RS-232 and RS-485 offer customers many standard, non-proprietary ways to interface with distributed control systems, building management systems and programmable logic controllers. PowerNet software solutions are your key to the power of information.

Product History Time Line


Product IMPACC Series I CONI PONI (1200) MINT IMPACC Series II TSF (Time Stamp Filter) PONI PONI (9600) MINT II IPONI Series III Waveform Display BPONI Series III E-BILL Trip Curve PowerNet Software Suite NetLink EPONI EMINT WEBPONI 1985 1990 1995 2000 Present

Figure 11-4. Product History Time Line

For more information visit: www.EatonElectrical.com

CA08105001E

Communication Systems Electrical Aftermarket Products and Services


March 2006
Aftermarket Solutions, Ref. No. [225]

11-7

IMPACC Upgrades Existing Assemblies with IQ Devices


Many Cutler-Hammer/Westinghouse electrical assemblies manufactured since 1989 were furnished with IQ devices as standard for metering and instrumentation. These assemblies are already communications capable. Some of the installed meters or trip units may or may not require the addition of PONI communication modules which enable the data to be transmitted to a master computer over a twisted shielded pair of conductors. The connectivity to the locations within a facility that have clusters of these communicating devices by use of the PowerNet system solution, can take various forms. The total solution in some instances could take the form of a combination of twisted shielded pair conductors and existing Ethernet for cost-effective economical remote communications never before possible with the IMPACC Series III software suite.

General Information
PowerNet communication solutions can be provided in new installations, retrot situations, or as updates to existing IMPACC Series III system solution installations.

Existing Other Manufacturers Equipment


Retrot kits of the Digitrip RMS microprocessor-based trip units are available for other manufacturers low voltage power circuit breakers, as well as Cutler-Hammer/Westinghouse DB, DS and SPB breakers. The Digitrip RMS trip units provide true rms current sensing, circuit protection, testing and energy monitoring functions for electrical circuits, as well as remote communications with the PowerNet system. Refer to the Low Voltage Switchgear Tab 17 of CA08101001E for more information on retrotting power circuit breakers in electrical assemblies. IQ metering devices can also replace many electromechanical, thermal, or analog devices on Cutler-Hammer/ Westinghouse and other manufacturers equipment to provide a signicant improvement to the quality and quantity of information available. For example, an IQ 200 can replace an ammeter, voltmeter, ammeter and voltmeter switch, wattmeter, varmeter, power factor meter, frequency meter, and watthour meter with one compact solid-state unit. Refer to the IQ products Tab 10 of this catalog for simple, easy to install methods of adding IQ devices to existing equipment. For more information on retrotting electrical distribution equipment, contact your local Eaton Field Sales ofce.

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25

Existing Assemblies without IQ Devices


IQ communicating devices can be easily retrotted to existing electrical assembly equipment. There are many locations throughout an electrical distribution system where new metering, relaying, trip unit, and/or digital input/ output devices can be located to perform key tasks targeted at Power Quality, Energy Management, and/or Reliability and Uptime. Refer to the IQ Products, Tab 10 of this catalog, for simple easyto-install methods of adding IQ devices to existing equipment.

CA08105001E

For more information visit: www.EatonElectrical.com

11-8

Communication Systems Electrical Aftermarket Products and Services


March 2006

IMPACC Upgrades

Aftermarket Solutions, Ref. No. [226]

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25

General Information (Continued)


Existing Communication System Updating Information
PowerNet communication solutions can be provided in new installations or provided as updates to existing IMPACC Series III systems. IMPACC Series III system installations have been noted to be everywhere from simple single workstation solutions to complex facility-wide and multi-facilitywide integrated system installations. There are six areas of exploration that should be focused on when planning the update of an existing Series III system to the latest PowerNet solution. These include: 1. System architecture/functionality considerations. 2. Inventory communication hardware used. 3. Inventory existing Series III software. 4. Master PC requirements. 5. Identifying graphics interface software used. 6. Inventory connectivity solutions employed. Please see the following sections for details on each of the above.

System Architecture/Functionality Considerations


IMPACC Series III software was designed to provide full functionality and run on a single station computer. Networked system solutions included the implementation of HMI applications such as Wonderware and utilization of Network implementation of the Dynamic Data Exchange (DDE) communication protocol over Microsoft networks.
A good understanding of the system architecture of Series III installations is important to ensure the update meets the existing functionality, as well as ensuring all equipment is located and

From a master control PC, either on-site or offsite, the plant operator, facilities engineer and/ or maintenance engineer could monitor and/or control the entire power distribution system. Information could also be made available to other PCs at different locations within a facility. Shielded twisted pair communications wire in an IMPACC system could extend 7,500 feet without the use of repeaters. Phone lines and modems may have been used to extend an IMPACC system to monitor and control off-site locations that may be hundreds or thousands of miles from the master control unit.

On-site Location

Off-site Location

WLI Load Interrupter Switchgear


Metering information. Switch position. Blown fuse indicator.

Medium Voltage VacCladW Metal-Clad Switchgear


Breaker status

AMPGARD Medium Voltage Starters


Motor status

Low Voltage Switchgear Type DS II


Breaker status

Low Voltage Switchboards Pow-R-M-S and Pow-R-M-S/F


Breaker status (Open/

(Open/Close/Trip). Cause and magnitude of trip. Breaker control (Open/Close). Metering values. Time stamping of events. Setup values (congured remotely).

(Stop/Run/Trip). Cause and magnitude of trip. Motor control (Trip/Reset). Operational data (motor run time, number of operations). Metering data. Time stamping of events. Trip setup values. Motor winding/bearing temperatures.

(Open/Close/Trip).
Cause and magnitude

Close/Trip).
Cause and magnitude

of trip. Breaker control (Open/Control). Metering values. Trip rating. Time stamping of events.

of trip.
Breaker control

(Open/Close).
Metering values. Trip rating. Time stamping

of events.

Figure 11-5. Identifying Potential Locations of Communication Equipment for Upgrading


For more information visit: www.EatonElectrical.com CA08105001E

Communication Systems Electrical Aftermarket Products and Services


March 2006
Aftermarket Solutions, Ref. No. [227]

11-9

IMPACC Upgrades

General Information (Continued)


updated appropriately. In most cases, the new features and architecture of PowerNet system software can be implemented to meet and exceed current system solution congurations. Some functionality changes that have been realized with the introduction of PowerNet as a direct replacement to the Series III software include the following and must be considered in this update process.

1
Series III software was a single station only solution. PowerNet introduced the ability to port monitoring, trending, waveforms, billing and other event type information over an existing Ethernet LAN, bringing the information to the expert and not the expert to the information. Series III software could only talk to devices over an INCOM twisted shielded pair network connected to hardware installed in the ISA slot of the PC, or connected to the RS-232 port of the computer. PowerNet can communicate with INCOM devices connected the same as Series III, but

Series III data logging nal destination was in the form of Comma Separated Variable (CSV) les. PowerNet utilizes Microsoft Access database les.

also connected directly to Ethernet or to multiple INCOM devices connected to Ethernet via networking hardware. Series III integration to HMI software such as Wonderware was implemented via DDE tags only. PowerNet enhanced the DDE communications, changing tag information, as well as adding ActiveX resources, enabling considerable reduction of custom screen creation for device faceplate access. PowerNet also introduced, OLE for Process Control (OPC) communication capabilities.

2 3 4 5 6 7 8

With IMPACC compatible devices, the customer had the ability to monitor, control and obtain information at the individual equipment or equipment lineup.

9 10 11 12 13 14 15 16 17 18

Low Voltage Switchboards and Pow-R-Line 4B/F Panelboards


Metering values. Energy values.

Motor Control Centers


Motor status

PWM Adjustable Frequency Controllers


Drive status. Metering values. Cause and magnitude

Transfer Switches
Metering data. Transfer switch status. Remote test.

Busway Systems
Energy usage readings. Power usage readings.

19 20 21 22 23 24

(Stop/Run/Trip).
Motor control

(Stop/Start/Reset). Cause and magnitude of trip. Operational data (motor run time, number of operations). Metering data. Time stamping of events. Trip setup values.

of trip.
Start, stop, speed

control of drive. Time stamping of events.

Figure 11-5. Identifying Potential Locations of Communication Equipment for Upgrading (Continued)
CA08105001E For more information visit: www.EatonElectrical.com

25

11-10

Communication Systems Electrical Aftermarket Products and Services


March 2006

Hardware/Software

Aftermarket Solutions, Ref. No. [228]

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25

General Information (Continued)


Inventory Communication Hardware Used
The INCOM network consists of a twisted shielded pair of conductors that interface to one of the following hardware devices: Master INCOM Network Translator II (MINT II) attached to the COM port of computer. Computer Operated Network Interface (CONI) installed in ISA slot of computer. Ethernet Gateway (ETHERNETGATE) connected to Ethernet LAN. Modbus Gateway (MODGATE) connected to Modbus master equipment.

In some instances, as specied before, the computer running the Series III software is an industrial computer that has no monitor, keyboard, or mouse and is installed as a part of a larger system solution. This device is referred to as the Ethernet Gateway, catalog number ETHERNETGATE as listed left. In these situations, there is, typically, a main system computer that utilizes additional software solutions to integrate the system. The Ethernet Gateway is used as a way of utilizing the infrastructure of the currently installed Local Area Network (LAN) as a means of collecting data from remote substations. This is not the only item that will require updating if existing in the system. Series III system solutions, in some cases, incorporated a lot of non-standard equipment to meet various connectivity needs. In some instances, where multiple COM ports are required, port splitters were used to expand one COM port into 8, or even 16, equivalent COM ports for communications with remote or local MINT II devices (DIGIBOARD). These various system conguration requirements will have to be ascertained and accounted for before updating.

In all other instances where custom third-party equipment was used to achieve connectivity solutions, thirdparty vendors should be consulted for appropriate update paths and careful consideration of compatibility with the new PowerNet software to ensure a smooth update path.

Inventory Existing Series III Software


Series III software consists of the main Series III package that includes the engine communicating to the devices through the CONI or the MINT II hardware. Series III came in various packages supporting 20, 200, and/or 1000 devices. The Series III software included most functionality in a single operator interface. It included, but was not limited to, the following features:

In the rst two instances above, the computer running the Series III software will have utilized the Computer Operated Network Interface (CONI) card installed in the ISA slot of the computer, the Master INCOM Network Translator II (MINT II), or a combination of both of these products. When updating the software at an existing installation, careful consideration should be administered and all new PowerNet interface hardware options considered when constructing the update bill of material. The CONI, in all cases, will have to be updated to the CONI3 device or equivalent interface communication hardware devices Eaton offers that meet the needs of the application. As the CONI3 utilizes the ISA slot of the computer, and most new computers do not come equipped with an ISA slot, substituted communication hardware may be required.

Update Path:
CONI1A products replaced with CONI3.
Note: When updating the computer for the new system software, ISA slots may not be available. In these instances, EMINT or NetLink products are typically employed.

Monitoring of all real-time parameters from the congured devices. Access to change or view the set points of those devices that support this functionality. Logging of selected parameters to ASCII Comma Separated Variable (CSV) les. Device Alarming notication and conrmation viewable via user interface and historically captured in ASCII CSV les. Built-in Dynamic Data Exchange (DDE) server capabilities.

MINT II devices are compatible with PowerNet and will not require updating. ETHERNETGATE products should be replaced with NLE1T or NLE2T hardware. MODGATE products should be replaced with NLM1T or NLM2T hardware. MMINT, MEMINT.

In addition to the basic Series III software package, add-on applications were available that expanded the basic functionality of the monitoring software including, but not limited to, the following features: Energy billing and cost allocation. Waveform display. Trip curve display. Modbus Gateway capabilities.

For those unique applications that may have Ethernet and Modbus on the same gateway node, the NLD1T or NLD2T product hardware incorporates both Modbus and Ethernet capabilities on the same box.

For more information visit: www.EatonElectrical.com

CA08105001E

Communication Systems Electrical Aftermarket Products and Services


March 2006
Aftermarket Solutions, Ref. No. [229]

11-11

Hardware/Software

General Information (Continued)


Table 11-2. Series III and Old NetPower Codes with PowerNet Product Codes
Description New PowerNet v. 3.3x Product Codes IMPACC Series III Product Codes Core Add-on Mods Energy Billing MODGATE3 PowerNet v.3.22 and Older Product Codes Core NPCORE1000 NPCORE100 NPCORE200 Add-on Mods NPWAVEFORM NPCOREMOD NPSETPOINT NPMONITOR NPMODBUS NPETREND Energy Billing NPBILLTRACK NPBILL1000 NPBILLDDE

1 2 3 4 5

NPCORE20

Connectivity Bundles Device Support


5-Device 10-Device 32-Device 100-Device 200-Device 500-Device 1000-Device PNCONNECT5 PNCONNECT10 PNCONNECT34 PNCONNECT100 PNCONNECT200 PNCONNECT500 PNCONNECT1000 PNSTD PNPQ

NPBILL200

NPEVENT

TRIPDPS3

NPCORE2

NPBILL20

EBILL200

ETREND

EBILLUL

ETRACK

WDISP3

EBILL20

NPOPC

NPDDE

S30200

S31000

ELOG3

S3020

7 8 9 10

PowerNet Bundles
Standard Client Power Quality

Integrator Package
Includes OPC, DDE, and Modbus Gateway 32 Energy Users 100 Energy Users 200 Energy Users 1000 Energy Users PNINTEGRATOR

11

Energy Billing PowerNet Bundles


PNBILL32 PNBILL100 PNBILL200 PNBILL1000

12 13 14 15 16 17 18 19 20 21 22 23 24 25

CA08105001E

For more information visit: www.EatonElectrical.com

11-12

Communication Systems Electrical Aftermarket Products and Services


March 2006

Hardware/Software

Aftermarket Solutions, Ref. No. [230]

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25

General Information (Continued)


Master PC Requirements
When planning to update a Series III system, replacement of the personal computer will be required. Due to the operating system as well as memory requirements, the Series III computer will not meet the requirements for a PowerNet computer.

Connectivity with the Series III system solutions included the following methods:

Dynamic Data Exchange (DDE)


Used in conjunction with Human Machine Interface (HMI) software applications such as Wonderware and Intellusion. These applications could also be installed on remote computers when PowerNet DDE is utilized to share information over a network. When reviewing an installation, this fact may not be readily discernible and some investigation may be necessary.

keyboard, or mouse) with a Modbus server software application installed. The functionality of the software installed on the Industrial PC focuses on Modbus register conguration and availability. Other monitor, DDE and trending features common to Series III are not available.

Update Path:
NLM1 or NLM2: Series III catalog number MODGATE. NLM1 provides one COM Port for Modbus communications and one INCOM port for communication with INCOM devices. NLM2 provides one COM port for Modbus communications and two INCOM ports for communications with INCOM devices. Modbus registers need to be recongured on NetLink as registers are not transferrable.

Update Path:
The PC requirements may change with later versions of the PowerNet software applications. Please refer to the Eaton Web site for updated information on PC requirements: www.EatonElectrical.com.

Update Path:
When updating the Series III software in the section above, DDE comes as a part of the update path.
Note: For remote nodes running Wonderware or any other HMI software application, the following catalog number can be purchased and installed on the remote PC eliminating the need for implementation of the Microsoft NETDDE solution. NPDDE PowerNet DDE Server client application software. Locate this software on the same computer as the HMI software.

Identify Graphics Interface Used


The IMPACC Series III software was sold with an option for an Enhanced Graphics application, a Wonderware InTouch software HMI solution. The screens were typically developed by Eaton as a turnkey solution, but this software could be purchased separately with development performed by the customer, or by independent local integrators. The graphics application could be located on the local Series III computer or on remote networked computers. It is important to identify all computers in the system that have the Enhanced Graphics application installed.

RS-232 (MINT II with Custom Driver in Master System)


Used in conjunction with Building Management Systems, Distributed Control Systems, or even PLCs. In this case, the customer has written or contracted to have written a custom driver that communicates directly to the installed INCOM devices via the MINT II RS-232 interface.

Modbus (Series III Computer as Modbus Gateway)


Used in conjunction with Building Management Systems, Distributed Control Systems, or even PLCs where the Modbus master equipment is connected to the communication serial port of the Series III computer. The Modbus add-on to Series III enables the COM port of the computer to be congured as a Modbus slave, providing the customer the ability to congure input and holding registers.

Update Path:
Series III software is not a part of this conguration. There is no update path; the MINT II is still a viable solution. For those applications that connect with the Johnson Controls Metasys System via the MINT II and Metasys Integrator, the JMI should be used.

Update Path:
PowerNet is compatible with Wonderware InTouch version 7.1 and above. All HMI software locations will require updating to the latest version via the following catalog numbers:
Note: When updating the graphics application to interface with the PowerNet DDE Server, due to DDE Tag changes, a review of the Tags displayed and used for control will be required for proper modication. Development time must be allocated for this update.

RS-232 (Series III PC COM Port Gateway, Custom Driver in Master System)
Used in conjunction with Building Management Systems, Distributed Control Systems, or even PLCs. Most common applications include BMS software such as Johnson Controls Metasys System integration. Where customers implemented this solution, the need for the functionality of the Series III is apparent but the sharing of data is required. Updating to PowerNet must pay close attention to this need.

Update Path:
NPMODBUS: Client application that turns the COM port of the computer into a Modbus server application. Client can be located on any computer with appropriate operating system and on the same network as the rest of the PowerNet system software. NPCOREMOD: Turns the COM port of the computer running the PowerNet software core into a Modbus server. This can only be located where the Core software application is located.

For those computers networked and running Wonderware InTouch runtime or view-only nodes, PowerNet DDE can be removed and local DDE Server client applications installed for more reliable and quality local DDE communications.

Update Path:
Series III had the ability to congure the COM port of the computer into a gateway which made the COM port look like a MINT II to the master communicating software application. This functionality is not included in the PowerNet software suite of applications. Connectivity is left to DDE, OPC, or Modbus communications. Before updating, the master software suite vendor should be consulted as to which of the above protocols is supported and appropriate steps for integration taken.
CA08105001E

Identify Connectivity Solutions Employed


Communication system solutions will, in some cases, implement software and/or hardware equipment to share the information gathered from installed meters, relays, and I/O devices with other software and/or systems including Distributed Control Systems (DCS), Building Management Systems (BMS), or Programmable Logic Controllers (PLC).

Modbus (Industrial PC as Modbus Gateway)


Used in conjunction with Building Management Systems, Distributed Control Systems, or even PLCs where the Modbus master equipment is connected to the communication serial port of the Series III computer. Available for sale was an industrial computer (no monitor,
For more information visit: www.EatonElectrical.com

Communication Systems Electrical Aftermarket Products and Services


March 2006
Aftermarket Solutions, Ref. No. [231]

11-13

PowerNet Device Selection Chart

General Information (Continued)


Table 11-3. PowerNet Device Selection Chart
Addressable Relay II Digitrip OPTIM 1050 Communicating Device Function Selection Chart Metering Devices LV Breaker Trip Units Digitrip OPTIM 750 Network Protector Relays Digitrip RMS 910 Digitrip RMS 810 Protective Relays Miscellaneous Devices IQ Transfer Switch

1 2
Power Manager

Energy Sentinel

Power Sentinel

IQ 200/IQ 300

Digitrip 1150

Digitrip 3000

RTD Module

3
Quad XYZ

IQ DP-4000/ IQ DP-4100

IQ Analyzer

Advantage

MP-3000

FP-5000

IQ 500

4 5 6

Voltage (phase-phase) Voltage (phase-neutral) Current Phases Current Ground

50

Power
kW kWh kVA kVAh Vars Varh PF 31

AIM

7 8 9 10

31

Demand
kW Demand kVA Demand Ampere Demand kvar Demand

11 12 13 14 15

Power Quality
THD Current THD Voltage THD CBEMA/Crest Factor Frequency Current Waveform Voltage Waveform 31

Other Features
Downloadable Set Points Operations Count High Load Trip Target Data Remote Open/Close Start Prole Auxiliaries

16 17

18
2 1 0-32 2 0-32 4

Input/Output
Digital Input Digital Output Analog Input Analog Output 3 4(3) 1 4 1.06 1.05 1 3 8 1 5 2 4 11 1

19 20 21 22 23 24 25

Communication Modules
IPONI BPONI
INCOM Communications Std.

EPONI Ethernet PONI WEBPONI BIM CMU

AIM can accept 32 inputs which can be used as digital or analog.

CA08105001E

For more information visit: www.EatonElectrical.com

11-14

Communication Systems Electrical Aftermarket Products and Services


March 2006

Hardware

Aftermarket Solutions, Ref. No. [232]

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25

Technology Upgrades
Communication Hardware

PONI Family

Product Operated Network Interface (PONI) Devices


The Product Operated Network Interface (PONI) cards attach to Cutler-Hammer devices to enable communications. These cards serve various functions from Ethernet-type applications, to nonEthernet-type applications, ultimately playing a key role in facilitating the access to information that each of the Cutler-Hammer devices offer. The IPONI and BPONI enable communications over a twisted shielded pair INCOM device network. The Ethernet PONI and WEBPONI enable device communications over a 10 megabaud Ethernet network. Each PONI attaches to its associated product. The PONI modules obtain power from the host product. Cutler-Hammer PONI modules can be used as solutions for various applications. There are two basic groups which include the Ethernet enabled products and the non-Ethernet enabled products. The non-Ethernet product offerings include the IPONI and the BPONI. These devices are typically applied where there are more than one device connected in a network of devices by a dedicated twisted shielded pair of conductors (Ref. IMPCABLE). The communications medium is formatted to enable clean noise-immune communications even when routed around areas of high noise and typical electrical communication disrupting equipment. The IPONI and BPONI daisy chain is the same format as that used in devices that have built-in communications such as the Digitrip trip units and can be used in series with these communication network wiring.

The Ethernet product offerings enable a facility to leverage and strategically utilize the ever growing presence of Ethernet Local Area Networks and the common availability of Ethernet hardware. These include the EPONI, EPONIF and the WEBPONI. The EPONI and the EPONIF differ only by the wiring method used to connect to an existing Ethernet LAN. The EPONI connects to an existing Ethernet LAN via 10Base-T and the EPONIF connects via ber. The application of EPONI communication devices on existing Ethernet LANs must consider the effect of the non-deterministic nature of shared LANs on the application. Dedicated LANs are highly recommended. These PONIs are used in those applications where an existing Ethernet infrastructure can be utilized to access a small number of devices in remote locations where a common Ethernet LAN is accessible. The Ethernet PONI works together with the PowerNet software suite to make this Ethernet communications happen. The WEBPONI Ethernet product offering puts a Cutler-Hammer metering product on the Web. No other software is required when specifying the WEBPONI. All software needed to enable any Internet browser program such as Microsoft Internet Explorer or Netscape Navigator is packed into the WEBPONI. The data can be viewed directly from any Internet browser program such as Internet Explorer and/or Netscape Navigator. The WEBPONI provides live updating data for the meter being monitored, as well as waveform display capabilities and e-mail direct from the device to dened key e-mail addresses that need to know when an event occurs.

EPONI/EPONIF
With the addition of the Ethernet PONI modules, the Cutler-Hammer devices can connect to an Ethernet LAN once a static IP address is dened in the unit. The PONIs can be easily mounted to the appropriate Cutler-Hammer devices. The device placed on the Ethernet LAN can be accessed and work in conjunction with the PowerNet software installed on a remote computer or by a NetLink also connected to the same.

WEBPONI
With the addition of the WEBPONI modules, the Cutler-Hammer devices can be accessed directly via any Internet Web browser such as Internet Explorer and/or Netscape Navigator the ideal small system solution. PowerNet is not compatible with the WEBPONI unless the WEBPONI is congured in EPONI mode, thus shutting down the internal Web server and relinquishing command to the PowerNet software suite.

CONI Card

CONI Card

IPONI/BPONI
With the addition of the IPONI or the BPONI card, a Cutler-Hammer device or series of devices can communicate with the PowerNet software via a master unit such as a MINT II, NetLink, EMINT or CONI3 card installed in a personal computer. The PONIs can be easily mounted to the appropriate Cutler-Hammer device and daisy chain together to form a robust deterministic communication network of devices in a system solution. Systems employing the IPONI/BPONI type communications medium provide deterministic communication performance relied on by those critical solution applications, where this is of the utmost importance.

The Computer Operated Network Interface 3 (CONI3) is a master communication card that is mounted in a NetLink or a computers ISA expansion slot. The CONI3 maintains backward compatibility with existing IMPACC systems. When used in conjunction with PowerNet Bill software, it supports enhanced throughput and use with a Contact Input Card (CIC) for demand window synchronization of multiple meters based on a single utility sync pulse. As many as four CONI3 cards may be mounted in a computer or NetLink when used with the Cutler-Hammer PowerNet suite, increasing network performance.

For more information visit: www.EatonElectrical.com

CA08105001E

Communication Systems Electrical Aftermarket Products and Services


March 2006
Aftermarket Solutions, Ref. No. [233]

11-15

Hardware

Technology Upgrades (Continued)


The PowerNet software suite takes advantage of the CONI3s message cache allowing approximately twice the network throughput as a CONI1A. The CONI3 supports a DIP switch selectable base I/O address allowing multiple CONIs and reducing conicts with other computer cards. When used in conjunction with the PowerNet suite, no interrupts are required to be dedicated to the CONI3. Table 11-4. CONI3 Network Card
Description CONI3 Network Card Catalog Number CONI3

Johnson Metering Interface (JMI)

Johnson Metering Interface

Cutler-Hammer PowerNet networks. It is intended to record customer utility information by monitoring signals from primary measurement devices such as gas and water ow transducers, pulse output contacts, BTU and steam ow meters, temperature and pressure sensors, equipment run-time and other devices.

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

The JMI is a user-friendly interface for Cutler-Hammer Power Management Products installed on the N2 bus of a Johnson Controls Metasys System. The JMI is ideal where a PowerNet system is not utilized and a direct connection of Cutler-Hammer power management products to an existing Metasys Building Automation System is desired. This product, coupled with a meter or series of meters, is a unique solution for applications where it is more economical to take advantage of an existing N2 bus infrastructure to combine select power monitoring information with an existing Building Automation System. Interfaces INCOM devices directly to the Johnson Control N2 bus. Presents electrical metering information from any IQ Multipoint Energy Submeter II, IQ Energy Sentinels, IQ Transfer, IQ Power Sentinels, IQ 200, IQ 300, IQ DP-4000 and IQ Analyzer.

MINT II

32 input channels, non-isolated, +/- 10 volts maximum 499 ohm input impedance. Capacitor backedup RAM. Current input: 0 20 mA dc accuracy +/- 0.02 mA from 0.2 20 mA (excludes sensor error) resolution 0.01 mA. Pulse input: Form A contact closure 10 Hz maximum, 50% duty cycle 10 mS de-bounce. Run-time input: Form A contact closure. Power supply: 120 Vac/24 Vdc.

Addressable Relay II (ARII)

Master INCOM Network Translator (MINT) II

The MINT II interfaces the IMPACC network to a master control unit with an RS-232 port, such as a personal computer serial port, a programmable controller RS-232 smart card, building management system interface card, etc. (Some software will have to be written in the master control unit to request and receive messages. The MINT II protocol is 10-character, ASCII coded hex.) The MINT II can be used to interface multiple IMPACC devices to Broadband LANs, telephone modem, or short haul modem. It can also be used to allow additional branches of the INCOM data line (ve additional branches per MINT II). The MINT II can be either table or panel mounted and requires a 120 Vac, 60 Hz supply. Selectable communication rate of 1200 or 9600 baud is available. The burden for the MINT II is 7 VA.

Note: The 6400/6600 Series of Analyzer must be programmed for the communication mode of the IQ Analyzer 6000/6200 series.

Powered from a 24 Vdc source which is also used by the N2 supervisory controller. Perfect for commercial applications where energy and power information is required.

Addressable Relay II

16 17 18 19 20 21 22 23 24 25

Analog Input Module (AIM)

The Addressable Relay II is designed for use where information or control of non-communicating devices is required remotely. The relays communicate on the PowerNet system. Devices are assigned a three-digit address to uniquely identify them on the daisy-chained twisted shielded pair network. The ARII has a Form C relay on board with two status indicating circuit inputs. The output relay can be activated and monitored remotely. Input status 1 and 2 can be monitored remotely.

Analog Input Module

The Analog Input Module (AIM) is a microprocessor-based analog input data acquisition device designed for use with

CA08105001E

For more information visit: www.EatonElectrical.com

11-16

Communication Systems Electrical Aftermarket Products and Services


March 2006

Hardware

Aftermarket Solutions, Ref. No. [234]

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17

Technology Upgrades (Continued)


IMPCABLE
The IMPCABLE was designed to be run in switchgear where codes require a 600 volt insulation rating. Typical blue hose cables are rated at 300 volts. The IMPCABLE is an 18 AWG cable with a 100 ohm impedance at 100 kHz tuned to work optimally with the FSK signal from Cutler-Hammer devices. The cable has been designed with characteristics that allow up to 1,000 devices or distances up to 10,000 feet from the master.
Polyethylene Filler

Ethernet NetLink
The Ethernet NetLink is a server for Cutler-Hammer PowerNet device information to PowerNet software clients on local or enterprise networks. The Ethernet NetLink enables the following functionality:

Dual Ethernet and Modbus NetLink


The Ethernet and Modbus NetLink combines the functionality of the Ethernet and Modbus NetLinks into one package. Table 11-5. Building the NetLink Catalog Number

Aluminum Shield Conductors

PVC Outer Jacket

Tinned Copper Braid

Drain Wire

Polyethylene Insulator

Connection of up to 200 PowerNet meters and protective relays to an Ethernet network. Localized data collection at the substation or equipment building level. Data logger capabilities to store event and trend information from attached PowerNet devices. Flexible system placement on a dedicated or shared facility Ethernet networks. A 10Base-T port for communications at 10 Meg baud on any Ethernet network supporting TCP/IP packets. Remote conguration which is kept safe in non-volatile memory. Available for purchase with either one or two INCOM parts to increase data throughput where required.

N L
E = Ethernet Output M = Modbus Output D = Dual Communications Ethernet and Modbus 1 = Incom Port (CONI Card) 2 = 2 INCOM Ports (CONI Cards) T = 10Base-T Ethernet Port/AUI (standard)

Contact Input Card (CIC)

Modbus NetLink
The Modbus NetLink is a server for PowerNet device information to Modbus master equipment via Modbus RTU registers over an RS-232 communication medium. The Modbus NetLink enables the following functionality: Connection of up to 200 PowerNet meters and protective relays into Modbus RTU registers. Register mapping technique to map up to 10,000 read registers for realtime data and read/write registers for control commands. A 10Base-T port for direct conguration, which is stored in non-volatile memory. Available for purchase with either one or two INCOM ports to increase data throughput where required.

Figure 11-6. IMPCABLE

NetLink

Contact Input Card (CIC)

NetLink

18 19 20 21 22 23 24 25

The NetLink translates INCOM Frequency Shift Key (FSK) to standard Ethernet TCP/IP messages or to Modbus RTU. Additionally, the product acts as a data logger to store event and trend information.

The Contact Input Card (CIC) works in conjunction with Cutler-Hammer PowerNet Energy Billing Software and a CONI3 to synchronize all demand windows for energy billing to a single synchronization pulse. The card is located in a Master Computer. Only one card is required in a system. The location of the Contact Input Card should be the Master Computer closest to the available utility synchronization pulse. A CONI3 Card is required in conjunction with the CIC. Table 11-6. Utility Synchronization Contact Input Card
Description Utility Synchronization Contact Input Card Catalog Number CIC

For more information visit: www.EatonElectrical.com

CA08105001E

Communication Systems Electrical Aftermarket Products and Services


March 2006
Aftermarket Solutions, Ref. No. [235]

11-17

Further Information
Publication Number TD.17.15.T.E TD17B.01.T.E TD.17.16.T.E TD.17.17.T.E TD.17.18.T.E TD.17.19.T.E TD.17.20.T.E TD.17.21.T.E TD.17.22.T.E TD.17.23.T.E TD.17.24.T.E TD.17.25.T.E TD.17.26.T.E TD.17.27.T.E TD.17.28.T.E TD02003003E TD02603002E TD02603004E Description PowerNet PowerPort NetLink CONI Card Contact Input Card (CIC) MINT II RS-232 Converter PONI Communication Modules Analog Input Module (AIM) Addressable Relay II Assemblies Electronic Monitor (AEM II ) Breaker Interface Module (BIM) Central Energy Display (CED) Advantage Central Monitoring Unit (CMU) DeviceNet Gateway (DGATEIM) IMPCABLE WEBPONI Johnson Metering Interface (JMI) IRMINT/Wireless Transceiver

Cutler-Hammer is a federally registered trademark of Eaton Corporation. Microsoft, Access, Explorer, Windows and ActiveX are registered trademarks of Microsoft Corporation. Johnson Controls and Metasys are federally registered trademarks of Johnson Controls, Inc. Modbus is a registered trademark of Modicon a division of Schneider Electric Industries SA. Navigator is a registered trademark of Netscape Communications Corporation. GraphWorX32, TrendWorX32, AlarmWorX32 and WEBHMI are registered trademarks of ICONICS, Inc. Wonderware and InTouch are registered trademarks of Invensys Systems, Inc.

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25

Pricing Information
Price and Availability Digest (PAD) Vista/VISTALINE Discount Symbol C10-S25

CA08105001E

For more information visit: www.EatonElectrical.com

11-18

Communication Systems Electrical Aftermarket Products and Services


March 2006
Aftermarket Solutions, Ref. No. [236]

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25

This page intentionally left blank.