You are on page 1of 3

P3 Bid for Design, Financing, Construction, Equipment and FM of Smouha Maternity University Hospital

Egyptian Ministry of Health Alexandria University

Response to Bid Doc. Ref

MATERIALS & EQUIPMENT LIST 1. DOMESTIC WATER PIPING INSULATION Supply, install, connect and test hospital Domestic, Kit., Laundry & CSSD hot water and hot water circulating systems piping insulation. - 28 mm diam . Piping ( 25 mm / 1" nom.diam). M. - 35 mm diam .Piping ( 32 mm /1 1/4" nom.diam). M. - 42 mm diam . Piping ( 40 mm /1 1/2" nom.diam). M. - 54 mm diam.Piping ( 50 mm / 2" nom.diam). M. - 67 mm diam.Piping ( 65 mm / 21/2" nom.diam). M. - 76 mm diam.Piping ( 80 mm / 3" nom.diam). M. - 108 mm diam.Piping ( 100 mm / 4" nom.diam). M. 2. WATER TANK CONNECTIONS Supply, install connect and test water tank connections and accessories complete, including galnized steel sleeves, inserts, frames, pipes & flanges for the two - compartment fire & domestic water pump suction lines supply filling lines, overflow pipes Water tank piping connections and accessories for hospital basment pump room. L.S. 3. PUMP ROOM DOMESTIC WATER PIPING SYSTEM Supply, install, connect and test all galnized steel domestic water piping system within pump room complete including pipies, fittings, flanges, unions, lves, hangers, supports and all other accessories as specified and as shown on drawings. L.S. 4. DOMESTIC WATER PIPING SYSTEM Supply, install, connect, and test copper piping systems for hospital Domestic, Kit, Laundry & CSSD, cold, hot and hot water circulating systems located all around the project except basement pump room, complete, including pipes and fittings, supports, - 15 mm diam . Piping ( 15 mm / 1/2" nom.diam). M. - 22 mm diam . Piping ( 20 mm / 3/4" nom.diam). M. - 28 mm diam . Piping ( 25 mm / 1" nom.diam). M. - 35 mm diam .Piping ( 32 mm /1 1/4" nom.diam). M. - 42 mm diam . Piping ( 40 mm /1 1/2" nom.diam). M. - 54 mm diam.Piping ( 50 mm / 2" nom.diam). M. - 67 mm diam.Piping ( 65 mm / 21/2" nom.diam). M. - 76 mm diam.Piping (80 mm / 3" nom.diam). M. - 108 mm diam.Piping ( 100 mm / 4" nom.diam). M. - 159mm diam.Piping ( 150 mm / 6" nom.diam). M. Supply, install, connect and test poly propylene domestic water piping system only for bathroom and toilet water supply systems as specified and as shown on drawings. - 15 mm diam . Piping ( 15 mm / 1/2" nom.diam). M. - 22 mm diam . Piping ( 20 mm / 3/4" nom.diam). M. - 28 mm diam . Piping ( 25 mm / 1" nom.diam). M. Supply, install, connect and test pressure type UPVC underground main water supply piping system, complete including all lves, water meter ult & acc. - 100 mm diam. Piping (4 nom. Diam.). M.
Page 1 of 3
T.H.E. Architects, Planners and Civil Engineers

P3 Bid for Design, Financing, Construction, Equipment and FM of Smouha Maternity University Hospital
Egyptian Ministry of Health Alexandria University

Response to Bid Doc. Ref

5. PLUMBING FIXTURES Supply, install, connect and test, hospital plumbing fixtures, trim and accessories complete including mixers, faucets, water supplies, stop angle lves, ablution faucets, bed pan washers, ..etc - Clinical Service Sink (CS-1). No. - Water Closet. No. - Wall Hung Urinal W/1.0 Gal. F.V. (UR-1). No. - Wall Hung Latory (L-1). No. - Single Compartment Sink (S-1). No. - Two Compartment Sink (S-2). No. - Hand Wash Sink (S-3). No. - Shower Stall. No. - Two Level Handicapped Accessible Electric Water Cooler (EWC-2). No. - Mop Sink (Corner) (MS-1). No. - BATH TUB No. 6. UNDERGROUND DRAINAGE PIPING SYSTEM Supply, install, connect and test schedule 40 rigid UPVC pipes and fittings, for interior and exterior undergound drainage installations according to specifications and as shown on drawings. - 50 mm Dia. Piping. M. - 65 mm Dia. Piping. M. - 80 mm Dia. Piping. M. - 100 mm Dia. Piping. M. - 150 mm Dia. Piping. M. - 200 mm Dia. Piping. M. - 250 mm Dia. Piping. M. - 300 mm Dia. Piping. M. Supply, install, connect and test floor cleanouts types as per specifications and as detailed on drawings. - 50 mm Diam Floor Cleanouts . No. - 80 mm Diam Floor Cleanouts . No. - 100 mm Diam Floor Cleanouts . No. - 150 mm Diam Floor Cleanouts . No. 7. ABOVEGROUND DRAINAGE VERTICAL & HORIZONTAL PIPING SYSTEM Supply, install, connect and test all soil, waste and vent hubless cast iron vertical horizontal aboveground piping system from all plumbing fixtures to outside the building complete including pipes, fittings, couplings, supports, hangers - 125 mm Diam. Piping System . M. - 100 mm Diam. Piping System . M. - 80 mm Diam. Piping System . M. - 65 mm Diam. Piping System . M. - 50 mm Diam. Piping System . M. 8. FLOOR DRAINS, ROOF DRAINS FLOOR RECEPTORS Supply, install, connect and test floor drains, roof drains and floor receptors all as specified and as shown on drawings. Floor Drains
Page 2 of 3
T.H.E. Architects, Planners and Civil Engineers

P3 Bid for Design, Financing, Construction, Equipment and FM of Smouha Maternity University Hospital
Egyptian Ministry of Health Alexandria University

Response to Bid Doc. Ref

- 100 mm Diam. - 50 mm Diam. Funnel Floor Drains - 100 mm Diam. Deck Drains - 100 mm Diam. Roof Drains - 50 mm Diam. - 100 mm Diam.

No. No.

No.

No.

No. No.

Page 3 of 3
T.H.E. Architects, Planners and Civil Engineers

You might also like