VAF

DIGITAL VOLT-AMP-FREQUENCY METER

Class 1.0 accuracy.

Compact 96 x 96 x 80mm DIN enclosure.

Ideal for individual feeders, Starters, LDBs etc...

Displays all 3 phase Volts and Amps, and Hz.

Micro Controller based.

True RMS.

Parameters Displayed: V, A, and Hz.


The VAF model meters are true RMS type digital meters for use in three phase four wire LT
electrical systems.
The design of these meters is based on proven micro- controller technology, resulting in a
compact and accurate meter. The design uses powerful micro- controller based technology.
TheThe meter uses state of the art Digital Signal Processing(DSP) circuitry to achive very
high accuracy measurement of true value of all parameters. The meter displays the readings
on Crisp Superbright 7 segment LED displays.
TECHNICAL SPECIFICATIONS

VOLTAGE INPUTS: Four wires of a 415 Volts Electrical System. (Other configurations
available on request.)
CURRENT INPUTS: 5 Amp.C.T. Secondaries from three phases. (Other configuration
available on request.)
DISPLAY

LOAD RANGE

: 3 digit Red 7 segment LED Display. Three parameters displayed


simultaneously.First page displays Ave. Volts,Ave. Amps and Hz.
Second page shows all three line voltages. Third page shows all
three Amps. The meter has a PAGE key for selecting the page
requird.
: 120% To 1% of rated CT primary.

Digital KWh meter

Class 1.0 /0.5 accuracy.


Compact 96 x 96-x 80 mm DIN enclosure.
Ideal for supervision & audit of specific loads.
Micro- Controller based.
True RMS.

Parameters Displayed: Kwh (Active Energy)


The ENTITY Energy are true RMS type digital meters for use in three phase three / four
wire electrical systems.
The design of these meters is based on proven micro- controller technology, resulting in
compact and accurate meters. The design uses powerful micro-controller based technology.
The meter uses state of the art Digital Signal Processing (DSP) circuitry to achieve very high
accuracy measurement of true RMS value of KWh. The meter displays the reading on an 8
digit LCD. The KWh reading is displayed directly as value, without need for any external
multiplying Factor (M.F)

TECHNIAL SPECIFICATIONS
VOLTAGE INPUTS: Three/Four wires of a 110/415 Volts Electrical system.
(To be specified at the time of ordering)
CURRENT INPUTS: 1 or 5 Amp. C.T. secondary from two/three phases. (To be
Specified at the time of ordering).
DISPLAY: 8 digit Liquid Crystal Display (LCD).
LOAD RANGE: 120% to 0.4% of rated CT primary.

DIGITAL ENERGY AND POWER METER


Class 1.0 accuracy.
Compact 96 x 96 x 80 mm DIN enclosure.
Ideal for supervision & audit of specific loads.
Capable of displaying up to 13 parameters.
Micro- Controller based.
True RMS.

Parameters Displayed: V, A, Kwh, KW, KVA, KVAR, PF, Hz.


The ENTITY+ Energy and power meters are true RMS type digital meters for use in
three phase three / four wire electrical systems.
The design of this meter is based on proven micro- controller technology, resulting in
compact and accurate meters. The design uses powerful micro-controller based
technology. The meter uses state of the art Digital Signal Processing (DSP) circuitry
to achieve very high accuracy measurement of True RMS value of all parameters
including KWh. The meter displays the reading on an 16 Digit Backlit LCD. All
parameters including KWh are displayed directly as the value, without need for any
external Multiplying Factor (M.F). The parameters to be displayed will continuously
keep scrolling on the easy-to-read display.

TECHNICAL SPECIFICATION

VOLTAGE INPUTS

: Three/ Four wire of a 110 / 415 Volts Electrical


Systems.(To be Specified at the time of ordering,by Purchaser)

CURRENT INPUT

: 1 or 5 Amp.C.T. Secondaries from two / three Phases.


(To be Specified at the time of ordering, by purchaser)

DISPLAY

: 16X1 Liquid Crystal Display (LCD).Parameters are displayed in


a continuously scrolling fashion. Scroll Lock key is provided
toFreeze the display at any particular parameter.

LOAD RANGE

: 120% To 0.4% of rated CT Primary.

OPERATING P.F.

: 0.2 Lag to UNITY to 0.2 Lead.

ELECTRICAL POWER METER


Multiparameter monitoring.
Replaces eight individual meters.
All parameters with accuracy class 1.0s.
Compact 96 x 96 DIN enclosure.
Micro controller based.
Ideal for supervision audit of specific loads, cost analysis & cross checking of
utility Billing meter.
Opional RS-485 port.
Opional Trip output.
The POWER PRO XT is an wire Electrical systems. It measures the phase voltages,
currents, power factor, system KVA, system KW, system KVAr and three energies.
The Various parameter measured are sequentially displayed on a 16 x 1 STN LC
display. The CT ratio (primary) can be programmed at site using the front membrane
keypad. The meter uses state of the art Digital signal processing (DSP) circuitry to
achieve very High accuracy measurement of true RMS value of all above parameters.
The meter accuracy is class 1.0s for all parameters including KWh. Processing of the
parameters is done using a powerful Microcontroller operating at 16 MHz. The main
advantages of using the POWER PRO XT are ease of installation (only three current
and three voltage inputs to be connected), economy of space and minimal wiring.

TECHNICAL SPECIFICATION

VOLTAGE INPUTS
: 4-wires of a 415 volt electrical system/3-wires from HT PT.
CURRENT INPUTS
:1/5 Amp.C.T. secondaries from three / two phases.
PARAMETER DISPLAYED: Three voltages, three currents, power factor, KVA,
KW,KVAr, KWh KVAh, KVArh, Hz, Demand & Maximum
Demand.
DISPLAY
: 16 x 1 LC display..
RESOLUTION: Phase voltages: 1 volt,
Phase current: 0.1Amp
Power Factor : 0.001unit
KVA,KW& KVAr: 0.01 unit
KVAh, KVARh & KWh: 0.01 unit
LOAD RANGE
: 120 % To 0.4% of rated CT primary.
OPERATING P.F
: ZERO LAG to UNITY to ZERO LEAD.
SIZE
Bezel: 96 x 96 MM

: Panel cutout: 92 x 92 MM.


Depth:140 mm.

APFCR

AUTOMATIC POWER FACTOR CORRECTION RELAY


*True RMS measurement.
*Available from 6 to 16 stage control.
*User configurable at site for number of stages.
*FIFO as well as VAR option site selectable.
*Reconnection time delay setting site selectable
*Bright 16 digit LC display for ease of reading and programming.
*No control mode to enable panel manual operation.
*Built in display for VOLTS, AMPS and PF.
*No need to set % KVAR,C/K ratio etc.
The oldest product stable now comes with a new look and a host of
features.This product is the result of more than 12 years of research and field
studies. Extreamely Rugged, dependable and field proven, it is rich in features
and ease of programming. The Relay has in built PF mode (FIFO) as well as VAR
(random switching) mode of operation to enable successful maintenance of PF
under all conditions.

TECHNICAL SPECIFICATIONS

*Measurement system : The PF is measured for any one phase from the voltage
senses between Phase and neutral and current in the
same phase, using Digital Signal Processing (DSP)
Methods.
*Supply Voltage :
230 VAC, 50 Hz nominal between phase and neutral.
*Supply Voltage Range : 80 to 270 VAC.
*Current:
5 Amps from CT secondary.
*Output switching capacity : 5 Amps @ 230 VAC resistive load.
*No. of stages :
Standard 6, 8, 10, 12 and 16 stages.
*Target PF setting :
From 0.8 (Lag) to unity in PF mode, and 0.8
(Lead) in VAR mode.
*Reconnection Time Delay : Settable at site, from 5 seconds to 120 seconds.
*Minimum Current :
5% of rated CT primary in PF mode, and 1.0% in
case of VAR mode.
*Mounting :
Flush mounted using clamps.
*Size :
144 x 144 mm bazel, 138 x 138 mm cutout size.
*Depth of Installation:
95 mm including terminal

GLOBLIN
ELECTRICAL LOAD MANAGER
Measurement, Control, Data, Logging, Communication
1) Displays more than 20 Parameters.
2) Large 20 x 4 Backlit LC Display.
3) Four Relay contacts, individually field programmable, for alarm parameter as
well a on/off values.
4) RS-485 MODBUS-TRU Connectivity.
5) RS-232 port.
6) On board 32 KB of non-volatile memory. On board data logging with field
programmable log duration.
7) CT / PT ratio field programmable.
8) Odd Harmonic Analysis up to 15th for all voltages and currents, including THD.
The digital power meter GOBLIN is a micro-controller based unit which not only
measures a host of electrical Parameters to display them on a 20 x 4 backlit LCD, but
also acts as a comprehensive load managing devised due to its four numbers of output
relay contacts. These outputs are individually field programmable for both the
parameter on which to generate alarm as well as the values on which to active alarm
and deactive it. In addition to this flexibility in term of load management, the meter
has serial ports: RS232C and RS485 as standard feature. The protocols supported
are MODBUS RTU for RS485 multi-drop systems and a proprietary TRINITY-1U
protocol for downloading logged data on a point-to-point basis.
The unit is meant for use in three phase four wire/ three wire systems. In three
phase four wire systems, it requires Four wires from R, Y, B & N in addition to six
wires from the three current transformers mounted on the three Phase. It thus the
three wattmeter method to arrive at the system KVA and KW. On the other hand, for
use in three wire system, it requires three phases from the PT secondary (usually 110
V AC ) and only four wires from the current teansformer secondaries of two phases.
The KVA and KW are calculated by the two wattmeter method.
The load manager GOBLIN, is a versatile meter, with all the features need to
implement a robust electrical load Management system. It can be configured to suit
most control and communication needs. This is achieved by making as many parameters
field programmable, as possible.

TECHNICAL SPECIFICATIONS
SUPPLY

: Three Phases & Neutral of a 3P4WLT electrical system.


or Three Phases (direct or from HTPT) of 3P3W system.

CT CONNECTION

: 5 Amp/ 1 Amp CT Secondary to be specified by the user.

PT & CT RATIO

: Site Selectable using front keypad.

DISPLAY

: 20 X 4 Backlit LCD, to display various parameters in four


pages.

PARAMETER DISPLAYED

: Three Phase to Neutral Voltages, Ttree Phase to


Phase voltages,Three Currents, Power Factors of all
three phases, System KVA,KW, KVAr & PF, KVAh, KWh,
and KVARh, Hz.,Demand & Max. Demand in trrms of
KVA / KW, Harmonic data for all Voltages & currents,
including THD.

ACCURACY

: Class 1.0

MEASUREMENT RANGE

: PF : 0 Lag to Unity to 0 Lead.

AMPS

: 0.4% to 120% of rated CT Secondary.

NUMBER OF RELAY CONTACTS : Four individually field programmable. User can


generate Alarms For Avg. Volts, Avg.Amps, KVA,
KW, KVAR, PF & Demand.
CONTACT RATING

: 5 Amp AC at 230 VAC, Resistive Load.

DATA LOGGING BUFFER

: 32 KB, Non-volatole memory, Can hold 1200


records.

LOGGING DURATION

: Site selectable from 1 minute to 60 minutes.

COMMUNICATION PORTS

: RS 232 C and RS 485

COMMUNICATION PROTOCOLS

: Modbus-RTU for RS 485 and Trinity-1U


(proprietory) for RS 232 C.

SIZE

: 144 x 144 mm (Bazel)


133 x 138 mm (Panel Cutout)

DEPTH OF INSTALLATION

: 90 mm.max.

OPERATING TEMP.

: 0 cel. To 50 cel.

POOJA TRADING ( BARODA )


ADDS: B/2: NARAYANDHAM SOCIETY, OPP: SWIMMING POOL,
WAGHODIA ROAD, BARODA-19.TELE:FAX:(0265)2517730.
MOBILE:9825367955,E-MAIL: UMESH9825367955@YAHOO.CO.IN

+SMART-DIGITAL POWER METERS+


TO,
RAMA NEWS PRINTS
OLPAD.

REF: Q/POWER/FEB/07
DT: 01/03/07

KIND ATTN: MR.A.K.JAIN SIR


SUB: QUOTATION FOR DIGITALPOWER METER

(VAF/ENTITY/ENTITY+/POWERPRO-XT/APFCR/GLOBLIN)

R/S:SIR.
THANKING YOU VERY MUCH FOR ENQUIRY FOR SUBJECT ITEMS AS DESIRED BY YOU,WE HEREBY
SUBMIT OUR FIRM OFFER FOR THE SAME AS BELOW.
SR

DESCRIPTION OF ITEM

MODEL

QTY

RATE/UNIT

VAFDIGITAL VOLT,AMP,FREQUENCY METER


DISPLAYED PARAMATER:
V,A,HZ(FREQUENCY)

VAF

01

2610=00

01

3960=00

01

5490=00

01

13500=00

01

18000=00

01

27270=00

Compact 96 x 96 x 80 mm DIN enclosure.


2

ENTITY DIGITAL KWH METER:


DISPLAYED PARAMATER:
Kwh (Active Energy)

Compact 96 x 96 x 80 mm DIN enclosure.


3

ENTITY + DIGITAL ENERGY AND POWER METER:


DISPLAYED PARAMATER: VOLTAGE, CURRENT, PF, FREQUENCY,
KW, KWH, KVA, KVAR, KVARH.

Compact 96 x 96 x 80 mm DIN enclosure.


4

POWER PRO-XT ELECTRICAL POWER METER:


DISPLAYED PARAMATER: THREE VOLTAGE, CURRENT, PF,
FREQUENCY, KW, KWH, KVA, KVAR KVAH KVARH, HZ DEMAND
& MAXIMUM DEMAND. *2-RELAY OUTPUT

LED DISPLAY

ENTITY
LCD DISPLAY

ENTITY +
LCD DISPLAY

POWER
PRO-XT
LCD DISPLAY

Compact 96 x 96 mm DIN enclosure.


5

APFCR AUTOMATIC POWER FACTOR CORRECTION RELAY

APFCR

True RMS ,Available from 6 to 16 stage control


User configurable at site for number of stages.

DISPLAYED PARAMETER:VOLTAGE,AMPERE,POWER FACTOR .

Compact 144 x 144 mm (Bazel)

LCD DISPLAY

GLOBLIN ELECTRICAL LOAD MANAGER:


DISPLAYED PARAMATER: VOLTAGE, CURRENT, PF,
FREQUENCY, KW, KWH, KVA, KVAR, KVARH, KVAH, HZ,
DEMAND & MAX.DEMAND, DEMAND IN TERMS OF KVA/KW,
INCLUDING THD. *4-RELAY OUTPUT

GLOBLIN

LCD DISPLAY

Compact 144 x 144 mm (Bazel)

****DISCOUNT ON ABOVE PRICE LIST@27% FOR PROJECTS********

*TERMS & CONDITIONS:


1) TAXES:
4% VAT EXTRA
2) OCTROI: AS ACTUAL
3) VALIDITY: 30-DAYS
4) DELIVERY: 2 TO 4 WEEK.
5) PACKING & FORWADING: AS APPLICABLE: 2 % EXTRA
6) PAYMENT:
AGAINST DELIVERY OR 30-DAYS.P.D.C.
7) WARANTTY: 1-YEAR WARRANTY AGNST ANY MFR. DEFECT
WE HOPE THAT THE ABOVE IS IN LINE WITH YOUR REQUIREMENT,WE AWAIT YOUR VALUED ORDER.

THANKS & REGARDS.


L TIN: 24191100486 DT:01-07-2002
C TIN: 24691100486 DT:11-09-2000

FOR POOJA TRADING


(UMESH PATEL).

YOUR SATISFECTION IS OUR MOTTO.