Professional Documents
Culture Documents
Slot Diffusers
Bar Grilles
Duct Grilles
Nozzles
Displacement Ventilation
VAV
10
Duct Heaters
11
SafidAir Devices
Contents
1
2
Type
Page
SCD
33
VK
48
Type
3
4
5
6
7
8
9
10
11
12
Page
SafidAir
Devices
Air Devices
SCD Series
Ceiling Diffusers
1
2
3
4
5
6
7
Product Description
The SCD type ceiling diffusers has been designed to handle a wide range of airflows and maintain a high
quality of air diffusion in occupied spaces. The SCD series can be used for supply, return and exhaust air
applications. Because this type of air outlet discharge horizontally near the ceiling, the warmest air in the
room will mixed immediately with the cool primary air far above the occupied zone. Therefore, this type of
air outlet is capable of handling large quantity of air at high temperature differentials. It has a pleasing
appearance that suit to any type of ceiling to match the architectural design.
8
9
10
Standard Construction
Materials:
The frame and blades of ceiling diffusers are made
of extruded aluminum alloy profiles.
Finish:
The standard coating finish is polyester powder
coating, white color RAL 9010, Code: Z0.
11
12
Optional Finish:
1. Natural anodized aluminium finish, Code: Z1
2. The powder coating can be of any color if
requested as specified, Code: Z2
Option:
The inner core of the diffuser can be fixed if
requested, Model: SCDF.
Damper:
The frame and blades are made of extruded
aluminum alloy profiles. If volume control damper
is required, it can be easily attached on the top
side of diffuser by means of a locking clips.The air
volume can be controlled by adjusting the damper
blades from the face of the diffuser by means of
screw driver.
Right to alterations reserved.
is
is aa registered
registered trade
trade mark.
mark.
copyright
copyright SAFID
SAFID 2008
2009 -- All
All Rights
Rights Reserved
Reserved
SafidAir
Devices
Air Devices
SCD Series
Ceiling Diffusers
1
Dimensions
2
3
4
5
6
7
8
9
Standard Sizes
10
Dimensions
11
Neck Size
12
RANGE
(Inches)
( mm )
( mm )
( mm )
( CFM )
6x6
150 X 150
147
285
50-225
9x9
225 X 225
222
360
112-506
12 x 12
300 X 300
297
435
200-900
15 x 15
375 X 375
372
510
312-1406
18 x 18
450 X 450
447
585
450-2025
SafidAir
Devices
Air Devices
SCD Series
Ceiling Diffusers
Performance Data
Supply Square Ceiling Diffusers
Model : SCD-4
1
2
TABLE 1
Neck Size
inches
(mm)
6x6
(150 x 150)
9x9
(225 x 225)
12 x 12
(300 x 300)
15 x 15
(375 x 375)
18 x 18
(450 x 450)
Ak
(ft)
0.138
0.278
0.463
0.694
0.968
Neck Velocity
Pressure drop
200
300
400
500
600
700
800
900
CFM
50
75
100
125
150
175
200
225
Throw
2-4
3-7
4-9
6-11
8-13
NC
<20
<20
20
25
29
34
37
43
CFM
112
168
225
281
337
393
450
506
Throw
4-7
5-9
7-11
9-13
NC
<20
20
23
27
32
37
40
45
CFM
200
300
400
500
600
700
800
900
Throw
4-7
7-10
9-13
NC
<20
20
26
33
36
42
45
47
CFM
312
468
625
781
937
1093
1250
1406
Throw
5-9
8-12
NC
<20
20
28
35
39
46
49
52
CFM
450
675
900
1125
1350
1575
1800
2025
Throw
6-9
9-13
NC
<20
25
7
8
9
10
11
12
35
40
45
50
55
Notes:
1. CFM is the total air capacity of each size.
2. Throw data ( in feet ) are based on isothermal air conditions at 100 and 50 FPM terminal velocity.
3. NC levels are based on 8dB room absorption.
4. Pressure drop in inches W.G.
5. Neck velocity in FPM.
6. Ak is the area factor.
is
is aa registered
registered trade
trade mark.
mark.
copyright
copyright SAFID
SAFID 2008
2009 -- All
All Rights
Rights Reserved
Reserved
SafidAir
Devices
Air Devices
SCD Series
Ceiling Diffusers
1
Performance Data
Supply Square Ceiling Diffusers
Model : SCD-3
2
3-WAY Air Pattern
3
4
5
6
TABLE 2
Neck Size
inches
(mm)
Ak
(ft)
6x6
(150 x 150)
0.138
9x9
(225 x 225)
0.278
12 x 12
(300 x 300)
0.463
15 x 15
(375 x 375)
0.694
18 x 18
(450 x 450)
0.968
7
8
9
10
11
12
Neck Velocity
200
300
400
500
600
700
800
900
Pressure drop
CFM
CFM1-Side A
CFM2-Side B
Throw-Side A
Throw-Side B
NC
CFM
CFM1-Side A
CFM2-Side B
Throw-Side A
Throw-Side B
NC
CFM
CFM1-Side A
CFM2-Side B
Throw-Side A
Throw-Side B
NC
CFM
CFM1-Side A
CFM2-Side B
Throw-Side A
Throw-Side B
NC
CFM
CFM1-Side A
CFM2-Side B
Throw-Side A
Throw-Side B
NC
50
12
19
2-4
3-5
<20
112
28
42
4-7
5-8
<20
200
50
75
4-7
5-8
<20
312
78
117
5-9
6-10
<20
450
112
169
6-9
7-10
<20
75
19
28
3-7
4-8
<20
168
42
63
5-9
6-10
20
300
76
112
7-10
8-11
20
468
118
175
8-12
9-13
20
675
169
253
9-13
10-14
25
100
26
37
4-9
5-10
20
225
57
84
7-11
8-12
23
400
100
150
9-13
10-14
26
625
157
234
11-16
12-17
28
900
226
337
12-17
13-18
30
125
31
47
6-11
7-12
25
281
71
105
9-13
10-14
27
500
126
187
11-15
12-16
33
781
195
293
13-18
14-19
35
1125
281
422
15-19
16-20
35
150
38
56
8-13
9-14
29
337
85
126
11-15
12-16
32
600
150
225
13-17
14-18
36
937
235
351
15-20
16-21
39
1350
338
506
17-21
18-22
40
175
43
66
10-14
11-15
34
393
99
147
13-17
14-18
37
700
176
262
15-19
16-20
42
1093
273
410
17-21
18-22
46
1575
393
591
18-23
19-24
45
Notes:
1. CFM is the total air capacity of each size.
2. Throw data ( in feet ) are based on isothermal air conditions at 100 and 50 FPM terminal velocity.
3. NC levels are based on 8dB room absorption.
4. Pressure drop in inches W.G.
5. Neck velocity in FPM.
6. Ak is the area factor.
Right to alterations reserved.
200
50
75
12-15
13-16
37
450
112
169
15-19
16-20
40
800
200
300
17-21
18-22
45
1250
312
469
18-23
19-24
49
1800
450
675
20-24
21-25
50
225
57
84
14-17
15-18
43
506
126
190
17-21
18-22
45
900
226
337
19-23
20-24
47
1406
352
527
19-24
20-25
52
2025
507
759
21-25
22-26
55
SafidAir
Devices
Air Devices
SCD Series
Ceiling Diffusers
Performance Data
Supply Square Ceiling Diffusers
Model : SCD-2
1
2
TABLE 3
Neck Size
inches
(mm)
6x6
(150 x 150)
9x9
(225 x 225)
12 x 12
(300 x 300)
15 x 15
(375 x 375)
18 x 18
(450 x 450)
Ak
(ft)
0.138
0.278
0.463
0.694
0.968
Neck Velocity
Pressure drop
200
300
400
500
600
700
800
900
CFM
50
75
100
125
Throw
4-8
5-10
7-12
9-14
NC
<20
<20
20
25
29
34
37
43
CFM
112
168
225
281
337
393
450
506
Throw
6-10
8-13
NC
<20
20
23
27
32
37
40
45
CFM
200
300
400
500
600
700
800
900
Throw
7-12
9-15
NC
<20
20
26
33
36
42
45
47
CFM
312
468
625
781
937
1093
1250
1406
Throw
8-14
NC
<20
20
28
35
39
46
49
52
CFM
450
675
900
1125
1350
1575
1800
2025
Throw
NC
150
175
200
225
5
6
7
8
9
10
11
12
25
30
35
40
45
50
55
Notes:
1. CFM is the total air capacity of each size.
2. Throw data ( in feet ) are based on isothermal air conditions at 100 and 50 FPM terminal velocity.
3. NC levels are based on 8dB room absorption.
4. Pressure drop in inches W.G.
5. Neck velocity in FPM.
6. Ak is the area factor.
is
is aa registered
registered trade
trade mark.
mark.
copyright
copyright SAFID
SAFID 2008
2009 -- All
All Rights
Rights Reserved
Reserved
SafidAir
Devices
Air Devices
SCD Series
Ceiling Diffusers
1
Performance Data
Supply Square Ceiling Diffusers
Model : SCD-1
2
1-WAY Air Pattern
3
4
5
6
TABLE 4
Neck Size
inches
(mm)
Ak
(ft)
0.138
9x9
(225 x 225)
0.278
9
10
11
Pressure drop
CFM
6x6
(150 x 150)
7
8
Neck Velocity
12 x 12
(300 x 300)
15 x 15
(375 x 375)
0.463
0.694
12
18 x 18
(450 x 450)
0.968
200
300
400
500
600
700
800
900
75
Throw
5-10
7-12
NC
<20
<20
20
25
29
34
37
43
CFM
112
168
225
281
337
393
450
506
Throw
7-13
NC
<20
20
23
27
32
37
40
45
CFM
200
300
400
500
600
700
800
900
Throw
9-15
NC
<20
20
26
33
36
42
45
47
CFM
312
468
625
781
937
1093
1250
1406
Throw
100
125
150
175
200
225
NC
<20
20
28
35
39
46
49
52
CFM
450
675
900
1125
1350
1575
1800
2025
Throw
NC
25
30
35
40
45
Notes:
1. CFM is the total air capacity of each size.
2. Throw data ( in feet ) are based on isothermal air conditions at 100 and 50 FPM terminal velocity.
3. NC levels are based on 8dB room absorption.
4. Pressure drop in inches W.G.
5. Neck velocity in FPM.
6. Ak is the area factor.
50
55
SafidAir
Devices
Air Devices
SCD Series
Ceiling Diffusers
Square Ceiling Diffuser Variants
3
Model : SCD -1, 2, 3, 4
: SCDF-1, 2, 3, 4
4
5
6
7
8
9
10
Model : SCD -1-V, 2-V, 3-V, 4-V
: SCDF-1-V, 2-V, 3-V, 4-V
11
12
SafidAir
Devices
Air Devices
SCD Series
Ceiling Diffusers
1
4
5
6
7
9
10
11
12
Standard Sizes
T-Bar Size
600 X 600
610 X 610
Neck Size
460 X 460
470 X 470
A
457
467
Note:
For the performance data, use the neck size 450 x 450 from Table 1 to Table 4.
B
595
605
SafidAir
Devices
Air Devices
SCD Series
Ceiling Diffusers
Fixing Details
11
4
5
6
7
8
9
Fixing To Plenum Box:
10
11
12
is aa registered
registered trade
trade mark.
mark.
is
copyright
copyright SAFID
SAFID 2008
2009 -- All
All Rights
Rights Reserved
Reserved
11
SafidAir
Devices
Air Devices
SCD Series
Ceiling Diffusers
1
2
3
Fixing Details
4
5
6
7
8
9
10
11
12