You are on page 1of 42

226347869.xls.

ms_office Security Level:


Huawei Industrial Base
Bantian, Longgang
Shenzhen 518129
People's Republic of China
Website: http://www.huawei.com
Email: support@huawei.com
Copyright Huawei Technologies Co., Ltd. 2009. All rights reserved.
No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of Huawei Technologies Co., Ltd.
Trademarks and Permissions
and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.
All other trademarks and trade names mentioned in this document are the property of their respective holders.
Notice
The information in this document is subject to change without notice. Every effort has been made in the preparation of this document to ensure accuracy of the contents, but all statements, information, and recommendations in this document do not constitute the warranty of any kind, express or implied.
Huawei Technologies Co., Ltd.
Address:
BSC6900 GSM V900R011C00
Parameter Reference
Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service. For any assistance, please contact our local office or company headquarters.
5/5/2014
Confidential Information of Huawei.
No Spreading without Permission
Page1of42
226347869.xls.ms_office Security Level:
Description Remarks
Parameter ID Simple string for identifying a parameter
Parameter Name Full name of the parameter
NE NEs on which the parameter is set
MML Command
Commands for setting the parameter, and optional/mandatory attribute of the parameter in
each command
Meaning Functions, functioning ways, and protocols of the parameter
Feature ID Relevant feature ID
Feature Name Features using the parameter
Value Type Parameter value type
GUI Value Range Parameter value range displayed on the GUI
Actual Value Range
Actual parameter value range corresponding to the GUI Value Range. For example, the
GUI Value Range is 0, and the corresponding Actual Value Range is OFF.
Unit Parameter value unit
Default Value Initial value provided by the system
Recommended Value Values recommended in different scenarios
Impact Parameter impact scope, that is, objects specified when the parameter is set
Parameter Relationship
Relationship between this parameter and other parameters. For example, to use this
parameter, you need to set related switches and parameters.
Access Whether this parameter is read/write or read only
Service Interrupted After Modification Whether modifying the parameter value may interrupt the existing services
Interruption Scope
Possible interruption scope in the case that modifying the parameter value may interrupt
the existing services
Interruption Duration (min)
Possible interruption duration in the case that modifying the parameter value may interrupt
the existing services
Caution Cautions to be taken during the modification
Validation of Modification
Requirements on how to validate the modification of the parameter. For example, you may
need to reset the device to validate the modification.
Impact on Radio Network Performance Impact of the radio parameter on the network performance
Introduced in Version Version in which this parameter is introduced
Attribute
Whether this parameter is a radio parameter, a transport parameter, or an equipment
parameter
Each parameter is described in the following aspects.
Purpose
This document provides information about the BSC6900 parameters, including the meaning, value, and usage of the parameters.
Intended Audience
Network planners
Field engineers
System engineers
Shift operators
Organization
5/5/2014
Confidential Information of Huawei.
No Spreading without Permission
Page2of42
226347869.xls.ms_office Security Level:
Parameter ID Parameter Name NE MML Command Meaning Feature ID Feature Name Value Type GUI Value Range Actual Value Range Unit Default Value Recommended Value Impact Parameter Relationship Access Service Interrupted After Modification Interruption Scope Interruption Duration(Min) Caution
SRN Subrack No. BSC6900 SWP BRD(Mandatory)STR BKP(Mandatory)CMP BRDAREA(Optional)ULD LOGTOOMU(Mandatory)STR CPUUSAGETST(Mandatory)ULD RSTINFO(Mandatory)ADD BRD(Mandatory)SET PWRPARA(Mandatory)SET FANSPEED(Mandatory)SET SCUPORT(Mandatory)ADD EMU(Mandatory)SET ALMPORT(Mandatory)DLD TCFILE(Mandatory)SET XPUPORT(Mandatory)ADD XPUVLAN(Mandatory)SET MPUBIND(Mandatory)LOD FAN(Optional)SET DPUBRDTYPE(Mandatory)CMP BRDVER(Optional)SYN BRDAREA(Optional)COL FAMLOG(Mandatory)CMP LICENSE(Optional)FMT DATA(Optional)CMP TBLDATA(Mandatory)SET CFGDATAINEFFECTIVE(Mandatory)SET CFGDATAEFFECTIVE(Optional)SET MSPCMD(Mandatory)SET E1T1LOP(Mandatory)LOP E1T1(Mandatory)STR E1T1TST(Mandatory)SET OPTLOP(Mandatory)PING IP(Mandatory)TRC IPADDR(Mandatory)SWP ETHPORT(Mandatory)SET QUEUEMAP(Mandatory)SET E1T1(Mandatory)SET MSP(Mandatory)ADD TSCROSS(Mandatory)ADD DEVIP(Mandatory)ADD IPRT(Mandatory)SET OPT(Mandatory)SET COPTLNK(Mandatory)SET ETHPORT(Mandatory)ADD ETHREDPORT(Mandatory)ADD PPPLNK(Mandatory)ADD MPGRP(Mandat Number of the subrack MRFD-210301Configuration Management Interval Type 0~11 0~11 None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ABISBYPASSMODE Abis By Pass Mode BSC6900 ADD BTS(Optional) Whether to enable the BTS to support bypass. HDLC and IP BTS is not support this parameter. GBFD-116601Abis Bypass Enumeration Type TRUE(Support), FALSE(Not Support) TRUE, FALSE None FALSE FALSE BTS None Read & Write Y BTS Less than 5 minutes None
ABISFCEN SDCCH Congestion Flow Control Allowed BSC6900 SET GCELLCCCH(Optional) Whether to permit Abis flow control.The flow control function acts on call management. If congestion occurs to the system, the system lightens its load by rejecting some services or prolonging the time for service requests. The Abis flow control is used to lighten the system load brought by Abis flows. GBFD-111705GSM Flow Control Enumeration Type NO(No), YES(Yes)NO, YES None None YES Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AbisFCTimer1 Abis Flow Control Timer 1 BSC6900 SET BSCTMR(Optional) Used together with "Abis Flow Control Timer 2" to control the change of cell flow control levels.When the flow control level in the cell changes, the values of MS MAX Retrans and Tx-integer in the system information are changed accordingly. When the immediate assignment fails, the BSC starts T1 and T2. GBFD-111705GSM Flow Control Interval Type 10~255 10~255 s None 30 BSC6900The value of this parameter should be smaller than "AbisFCTimer2". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AbisFCTimer2 Abis Flow Control Timer 2 BSC6900 SET BSCTMR(Optional) Used together with "Abis Flow Control Timer 1" to control the change of cell flow control levels.When the flow control level in the cell changes, the values of MS MAX Retrans and Tx-integer in the system information are changed accordingly. When the immediate assignment fails, the BSC starts T1 and T2. GBFD-111705GSM Flow Control Interval Type 10~255 10~255 s None 60 BSC6900The value of this parameter should be greater than "AbisFCTimer1". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AbisJamThreshold2StartLs Abis Jam Rate for BTS Local Switch BSC6900 SET BSSLS(Optional) Threshold for enabling the BTS local switching. When the congestion rate at the Abis interface exceeds this threshold, the BTS local switching is enabled. GBFD-117702BTS Local Switch Interval Type 0~100 0~100 per cent None 90 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ABISRESADJTCHHEN TCHH Preferred When Abis Resource Scarce BSC6900 SET GCELLCCBASIC(Optional) Whether the BSC prioritizes half rate channels to MSs according to the Abis resource load in the case of Abis resource shortage. If the parameter is set to yes, when the Abis resource load is higher than "Flex Abis Prior Choose Abis Load Thred" or "Fix Abis Prior Choose Abis Load Thred" in "SET GCELLCHMGAD", the BSC prioritizes half rate channels to MSs. GBFD-112013Abis Congestion Trigger HR Distribution Enumeration Type NO(No), YES(Yes)NO, YES None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ABISRESADJTCHHFUNSW TCHH Function Switch BSC6900 SET BTSFLEXABISPARA(Optional) This parameter specifies whether to enable the Abis resource adjustment TCHH function.This parameter specifies whether the TCHH is preferentially allocated to the MS by the BSC when Abis resources are insufficient.If the Abis resource load is greater than "Flex Abis Prior Choose Load Thred" or "Fix Abis Prior Choose Abis Load Thred" when the parameter is set to "YES", the BSC preferentially allocates the TCHH to the MS. GBFD-117301Flex Abis Enumeration Type NO(NO), YES(YES) NO, YES None None NO BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ABISTSFREETM Timer of Releasing Abis Timeslot BSC6900 SET GCELLPSCHM(Optional) Duration between Abis timeslot emptiness and Abis timeslot release. When channels are idle, the timer is started. When the timer is expired, the Abis timeslot is released. When all the TBFs on the channel are released, the Abis timeslot is not released at once. Instead, the timer is started when the channels are idle. Before the timer expires, if new service request is received, Abis timeslot is still occupied and timer is stopped; otherwise, the timeslot is released after the timer expired. GBFD-113101PDCH Dynamic Adjustment Interval Type 10~3600 10~3600 s None 15 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AbisVer Abis Interface Tag BSC6900 SET BSCBASIC(Optional) Phase tag for GSM protocols that the Abis interface supports MRFD-210301Configuration Management Enumeration Type GSM_PHASE_1, GSM_PHASE_2, GSM_PHASE_2Plus GSM_PHASE_1, GSM_PHASE_2, GSM_PHASE_2Plus None None GSM_PHASE_2 BSC6900The value of this parameter is the same as those of "Um Interface Tag" and "A Interface Tag". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ABLASTTIME AB_LAST_TIME[100 Millisecond] BSC6900 ADD AISSCFG(Optional) Duration for the BTS to collect the AB after the TRX or channel is activated. GBFD-118201Soft-Synchronized Network Interval Type 1~255 1~255 None 40 40 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None.
AbnormalMosThreshold Abnormal Voice MOS Threshold BSC6900 SET OTHSOFTPARA(Optional) Mean opinion score (threshold) for judging an abnormal call. The BTS computes the MOS of a call periodically and reports the call MOS to the BSC in custom measurement reports. According to the call MOS, the BSC checks whether the call is normal. If the call MOS is less than this threshold, the BSC considers the call abnormal and records the abnormity in the call history record (CHR).To prevent the impact of a decimal fraction, set this parameter to the product of 50 and the actual MOS. GBFD-116801Voice Quality Index (Uplink VQI) Interval Type 0~250 0~250 None None 100 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved If this parameter is set too high, a normal voice may be considered abnormal. If this parameter is set too low, an abnormal voice may not be considered.
ACCBURST Access Burst Type BSC6900 SET GCELLPSBASE(Optional) Access pulse type of the PRACH, uplink PTCCH and packet control acknowledge message of the MS.8bit: 8 bit pulse access mode; 11bit: 11 bit pulse access mode. GBFD-119110Access Enumeration Type 8BIT(8BIT), 11BIT(11BIT) 8BIT, 11BIT None None 8BIT Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ACCCONTROLCLASS Access Control Class BSC6900 SET GCELLPRACH(Optional) Access control class of the MS. GBFD-119110Access Interval Type 0~65535 0~65535 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ACCESSOPTILAY Incoming-to-BSC HO Optimum Layer BSC6900 SET GCELLHOIUO(Optional) Subcell preferred during the incoming inter-BSC handover to the concentric cell. In the case of incoming inter-BSC handover to the concentric cell, the channels in this subcell are preferred. GBFD-113201Concentric Cell Enumeration Type OSubcell(Overlaid subcell), USubcell(Underlaid subcell), NoPrefer(No preference) OSubcell, USubcell, NoPrefer None None Usubcell Cell This parameter is valid only when "IUOTP" in "ADD GCELL" is set to Concentric_cell. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AccStaServiceType PS Initial Access Service Type BSC6900 SET GCELLPSOTHERPARA(Optional) Whether the initial service is uplink, downlink, or neutral.0: The initial service is uplink priority; 1: The initial service is downlink priority;2: The initial service is neutral. GBFD-119501Adaptive Adjustment of Uplink and Downlink Channels Interval Type 0~2 0~2 None None 1 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ACCTHD AC control threshold BSC6900 SET FCCPUTHD(Optional) Access flow control threshold. When the average CPU usage of sliding windows exceeds the threshold, AC flow control is triggered. WRFD-040100Flow Control Interval Type 30~100 30~100 per cent None 80 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ACCTHD AC control threshold BSC6900 SET FCMSGQTHD(Optional) Access packet queue usage threshold. When the average packet queue usage of sliding windows exceeds the threshold, AC flow control is triggered. WRFD-040100Flow Control Interval Type 30~100 30~100 per cent None 75 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ACFC Address and control field compress BSC6900 ADD PPPLNK(Optional)ADD MPLNK(Optional) If this parameter is set to ENABLE, which is used to enable the function of the address and control area compression. If it is set to DISABLE, which is used to disable the function of the address and control area compression. GBFD-118611GBFD-118622 Abis IP over E1/T1A IP over E1/T1 Enumeration Type Disable(Disable), Enable(Enable) Disable, Enable None Enable Enable PPP link None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ACFC Address and control field compress BSC6900 ADD BTSPPPLNK(Optional)ADD BTSMPLNK(Optional) Whether to support compression flag bit for the address and control field GBFD-118611Abis IP over E1/T1 Enumeration Type Disable, Enable Disable, Enable None Enable Enable BTS None Read & Write Y PPP link Less than 5 minutes None
ACOOPERATPAGINGSWITCH A Interface Paging Co-ordination Switch BSC6900 SET BSCPSSOFTPARA(Optional) This parameter specifies whether to receive the CS paging request from A interface when the MS uses a PS service. This parameter is used to control the paging collaboration function of A interface of the entire BSC. This parameter specifies whether to forward the paging message of the A interface from the circuit domain to the PS domain (the forwarded paging message contains the paging cell list). None None Enumeration Type CLOSE(Close), OPEN(Open) CLOSE, OPEN None None CLOSE BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter is valid only when "BSSPAGINGCOORDINATION" in "SET GCELLPSBASE" is set to YES.
ACRTHD AC restore threshold BSC6900 SET FCCPUTHD(Optional) Access flow control recovery threshold. When the average CPU usage of sliding windows is lower than the threshold, AC flow control is stopped. WRFD-040100Flow Control Interval Type 30~100 30~100 per cent None 70 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ACRTHD AC restore threshold BSC6900 SET FCMSGQTHD(Optional) Access packet recovery threshold. When the average packet queue usage of sliding windows is lower than the threshold, AC flow control is stopped. WRFD-040100Flow Control Interval Type 30~100 30~100 per cent None 65 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ACS Additional reselect parameter indication BSC6900 SET GCELLIDLEAD(Optional) Used for notifying MSs where they retrieve relevant cell reselection parameters during cell reselection.The value of this parameter is 0 in system message 3, without any meaning.In system message 4, the value 0 of this parameter means MSs must retrieve the PI parameters and other parameters relevant to cell reselection and the parameters relevant to C2 calculation from the remaining bytes of system message 4. The value 1 means that the MS must retrieve the parameters from the remaining bytes of system message 7 or 8. GBFD-110402Basic Cell Re-selection Enumeration Type COMPUL0(Compulsory 0), COMPUL1(Compulsory 1), FLEX(Flexible) COMPUL0, COMPUL1, FLEX None None FLEX Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved ACS is usually set to 0 because system information 7 and 8 messages are seldom used in common cells. ACS should be set to 1 if system information 7 and 8 messages are used in a cell and C2 is used for cell reselection.
ACSW AC control switch BSC6900 SET FCSW(Optional) Whether to control AC flow WRFD-040100Flow Control Enumeration Type ON, OFF ON, OFF None None ON Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ACTCDSETF AMR ACS[F] BSC6900 SET GCELLCCAMR(Optional) Active coding set (ACS)[F], indicating a set of full rate coding rates currently available for calls. The AMR is a set of multiple speech coding and decoding rates. GBFD-115501AMR FR Bit Field Type 4_75KBIT/S~0 5_15KBIT/S~1 5_90KBIT/S~2 6_70KBIT/S~3 7_40KBIT/S~4 7_95KBIT/S~5 10_2KBIT/S~6 12_2KBIT/S 4_75KBIT/S, 5_15KBIT/S, 5_90KBIT/S, 6_70KBIT/S, 7_40KBIT/S, 7_95KBIT/S, 10_2KBIT/S, 12_2KBIT/S None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The number of the chosen data rates must be from one to four. If this parameter involves only one full rate coding rate, the value of "AMR Starting Mode[F]" can be 0 only; all the adjustable thresholds and hysteresis of AMR coding rate make no sense.If this parameter involves two coding rates, the value of "AMR Starting Mode[F]" can be 0 or 1; the values of the following parameters make sense while the other adjustable thresholds and hysteresis of AMR coding rate do not: "AMR UL Coding Rate adj.th1[F]", "AMR UL Coding Rate adj.hyst1[F]", "AMR DL Coding Rate adj.th1[F]", and "AMR DL Coding Rate adj.hyst1[F]".If this parameter involves three coding rates, the value of "AMR Starting Mode[F]" can be 0, 1, or 2; the values of the following parameters make sense while the other adjustable thresholds and hysteresis of AMR coding rate do not: "AMR UL Coding Rate adj.th1[F]", "AMR UL Coding Rate adj.hyst1[F]", "AMR DL Coding Rate adj.th1[F]", "AMR DL Coding Rate adj.hyst1[F]", "AMR UL Coding Rate adj.th2[F]", "AMR U
ACTCDSETH AMR ACS[H] BSC6900 SET GCELLCCAMR(Optional) Active coding set (ACS)[H], indicating a set of half rate coding rates currently available for calls. The AMR is a set of multiple speech coding and decoding rates. GBFD-115502AMR HR Bit Field Type 4_75KBIT/S~0 5_15KBIT/S~1 5_90KBIT/S~2 6_70KBIT/S~3 7_40KBIT/S~4 7_95KBIT/S 4_75KBIT/S, 5_15KBIT/S, 5_90KBIT/S, 6_70KBIT/S, 7_40KBIT/S, 7_95KBIT/S None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The number of the chosen data rates must be from one to four. If this parameter involves only one half rate coding rate, the value of "AMR Starting Mode[H]" can be 0 only; all the adjustable thresholds and hysteresis of AMR coding rate make no sense.If this parameter involves two coding rates, the value of "AMR Starting Mode[H]" can be 0 or 1; the values of the following parameters make sense while the other adjustable thresholds and hysteresis of AMR coding rate do not: "AMR UL Coding Rate adj.th1[H]", "AMR UL Coding Rate adj.hyst1[H]", "AMR DL Coding Rate adj.th1[H]", and "AMR DL Coding Rate adj.hyst1[H]".If this parameter involves three coding rates, the value of "AMR Starting Mode[H]" can be 0, 1, or 2; the values of the following parameters make sense while the other adjustable thresholds and hysteresis of AMR coding rate do not: "AMR UL Coding Rate adj.th1[H]", "AMR UL Coding Rate adj.hyst1[H]", "AMR DL Coding Rate adj.th1[H]", "AMR DL Coding Rate adj.hyst1[H]", "AMR UL Coding Rate adj.th2[H]", "AMR U
ACTCDSETWB AMR ACS[WB] BSC6900 SET GCELLCCAMR(Optional) Active coding set (ACS)[WB], indicating a set of wide-band coding rates currently available for calls. The AMR is a set of multiple speech coding and decoding rates. GBFD-115507WB AMR Bit Field Type 6_60KBIT/S, 8_85KBIT/S, 12_65KBIT/S 0~7 None None 7 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The number of the chosen data rates must be from one to three. If this parameter involves only one coding rate, the value of "AMR Starting Mode[WB]" can be 0 only; all the adjustable thresholds and hysteresis of AMR coding rate make no sense.If this parameter involves two coding rates, the value of "AMR Starting Mode[WB]" can be 0 or 1; the values of the following parameters make sense while the other adjustable thresholds and hysteresis of AMR coding rate do not: "AMR UL Coding Rate adj.th1[WB]", "AMR UL Coding Rate adj.hyst1[WB]", "AMR DL Coding Rate adj.th1[WB]", and "AMR DL Coding Rate adj.hyst1[WB]".If this parameter involves three coding rates, the value of "AMR Starting Mode[WB]" can be 0, 1, or 2; the values of the following parameters make sense while the other adjustable thresholds and hysteresis of AMR coding rate do not: "AMR UL Coding Rate adj.th1[WB]", "AMR UL Coding Rate adj.hyst1[WB]", "AMR DL Coding Rate adj.th1[WB]", "AMR DL Coding Rate adj.hyst1[WB]", "AMR UL Coding Rate adj.th2[WB]", "AM
ACTGENE Active Gene BSC6900 ADD GCELL(Optional) This parameter is contained in an assignment request along with the requested bandwidth. The bandwidth actually allocated to a user is the value obtained through multiplying the requested bandwidth by the value of this parameter. GBFD-118601Abis over IP Interval Type 5~10 5~10, step: 0.1 None 5 5 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The larger value this parameter is set to, the higher the bandwidth occupied by services is.
ACTL2REEST Activate L2 Re-establishment BSC6900 SET GCELLSOFT(Optional) Whether to activate the function of L2 re-establishment. If this function is activated, the BSC starts the attempt of L2 re-establishment when the BSC receives an ERR IND message reported by the BTS in a conversation of MSs. If the L2 re-establishment succeeds, the conversation continues; otherwise, a call drop occurs. GBFD-110501Call Control Enumeration Type NO(No), YES(Yes)NO, YES None None NO Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ACTTIME ACT_TIME BSC6900 ADD AISSCFG(Optional) Valid duration of the reserved TRX or timeslot. GBFD-118201Soft-Synchronized Network Interval Type 1~255 1~255 min 10 10 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None.
ACU Added CPU occupancy BSC6900 STR CPUUSAGETST(Mandatory) Increased CPU usage MRFD-210301Configuration Management Interval Type 1~95 1~95 per cent None None Board None Read & Write Y Board Less than 10 minutes None
ACVLTHD AC Voltage Lower Threshold BSC6900 SET BTSAPMUBP(Optional) AC voltage alarm lower threshold. When the input AC voltage is lower than the value of this parameter, an alarm indicating the abnormal AC is reported.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. GBFD-111202O&M of BTS Interval Type 60~300 60~300 V None 180 BTS The value of this parameter must be smaller than "AC Voltage Upper Threshold". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ACVOLALARMH AC overvoltage alarm threshold BSC6900 SET BTSDPMUBP(Optional) The BTS reports an alarm if the AC voltage exceeds the value of this parameter. GBFD-111202O&M of BTS Interval Type 610~3000 61~300 (step: 0.1) V None 2800 BTS The value of this parameter must be greater than "AC undervoltage alarm threshold". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ACVOLALARML AC undervoltage alarm threshold BSC6900 SET BTSDPMUBP(Optional) The BTS reports an alarm if the AC voltage is lower than the value of this parameter. GBFD-111202O&M of BTS Interval Type 600~2990 60~299 (step: 0.1) V None 1800 BTS The value of this parameter must be smaller than "AC overvoltage alarm threshold". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ACVUTHD AC Voltage Upper Threshold BSC6900 SET BTSAPMUBP(Optional) The BTS reports an alarm if the AC voltage exceeds the value of thAC voltage alarm upper threshold. When the input AC voltage is higher than the value of this parameter, an alarm indicating the abnormal AC is reported.is parameter.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. GBFD-111202O&M of BTS Interval Type 60~300 60~300 V None 280 BTS The value of this parameter must be greater than "AC Voltage Lower Threshold". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ADAPTASSIGNMENTFLOW Use Assign. Procedure in Intra-Cell HO BSC6900 SET GCELLSOFT(Optional) Whether to hand over a MS to another channel during an intra-cell handover through the assignment process GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Enumeration Type NO(No), YES(Yes)NO, YES None None NO Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ADC Alarm Disabled Configuration BSC6900 SET BTSAPMUBP(Optional) The APMU board supports 8 Boolean alarms. This parameter consists of 8 bits, each of which indicates whether the corresponding alarm is enabled or not. The bit value 0 indicates that the alarm is enabled, and the bit value 1 indicates that the alarm is disabled.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. MRFD-210304Faulty Management Bit Field Type NO1_DISABLE, NO2_DISABLE, NO3_DISABLE, NO4_DISABLE, NO5_DISABLE, NO6_DISABLE, NO7_DISABLE, NO8_DISABLE NO1_DISABLE, NO2_DISABLE, NO3_DISABLE, NO4_DISABLE, NO5_DISABLE, NO6_DISABLE, NO7_DISABLE, NO8_DISABLE None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ADC Alarm Disabled Configuration BSC6900 SET BTSDPMUBP(Optional) The DPMU board supports seven Boolean alarms. This parameter consists of seven bits, each of which indicates whether the corresponding alarm is enabled or not. The bit value 0 indicates that the alarm is enabled, and the bit value 1 indicates that the alarm is disabled.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. MRFD-210304Faulty Management Bit Field Type NO1_DISABLE, NO2_DISABLE, LIGHT_ARR, NO4_DISABLE, NO5_DISABLE, NO6_DISABLE, NO7_DISABLE NO1_DISABLE, NO2_DISABLE, LIGHT_ARR, NO4_DISABLE, NO5_DISABLE, NO6_DISABLE, NO7_DISABLE None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ADDR Communication Address BSC6900 SET BTSFMUABP(Optional)SET BTSAPMUBP(Optional)SET BTSDATUBP(Optional)SET BTSDEMUBP(Optional)SET BTSDHEUBP(Optional) Communication address of the CBUS3 on the bus 485. The configuration of this parameter must be consistent with the actual physical connection. Otherwise, the board may not work properly. GBFD-111202O&M of BTS Interval Type 0~254 0~254 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AddTransBwInt Interval to Apply Transmission Bandwidth when Not Congested BSC6900 SET BSCPSSOFTPARA(Optional) Interval for requesting the secondary link in the congestion state. GBFD-111705GSM Flow Control Interval Type 0~50 0~50 ms None 10 BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AddTransBwNum Number to Apply Transmission Bandwidth When Not Congested BSC6900 SET BSCPSSOFTPARA(Optional) Secondary link bandwidth that is requested each time in the congestion state. GBFD-111705GSM Flow Control Interval Type 0~768 0~768 None None 2 BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ADJBSCDPC Adjacent BSC DPC BSC6900 ADD EXTNCELL(Mandatory)COL BSCSYNCINFO(Mandatory) The destination signaling point (DSP) of the adjacent BSC must be an Iur-g DSP. GBFD-111804A Interface Protocol Process Interval Type 1~16777215 1~16777215 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None.
ADJMODE Adjustment Mode BSC6900 SET BTSEXCURSION(Mandatory)SET BSCSYNCOFF(Mandatory) Whether to adjust the BTS offset manually or automatically. GBFD-118201Soft-Synchronized Network Enumeration Type BYMANUAL(By Manual), BYAUTO(By Auto) BYMANUAL, BYAUTONone None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None.
ADJUSTULMCSTYPE Support EGPRS Uplink MCS Dynamic Adjust BSC6900 SET GCELLEGPRSPARA(Optional) Mode of dynamically adjusting the EGPRS uplink encoding scheme. Value 0 indicates dynamic adjustment of EDGE uplink coding scheme is not supported; value 1 indicates that the uplink coding scheme is adjusted according to the downlink signal quality in the DownLink ACK message; value 2 indicates that the uplink coding scheme is adjusted according to the bit error rate reported by the BTS. GBFD-119204Dynamically Adjusting the Uplink MCS Coding Enumeration Type 0(Not support dynamic adjustment), 1(According to the dl signal quality in the DL ACK), 2(According to the bit error rate reported by the BTS) 0, 1, 2 None None 1 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ADLDACT Auto Download Active Function Switch BSC6900 SET BTSAUTODLDACTINFO(Optional) Whether to enable the function of automatically downloading and activating the BTS software GBFD-111202O&M of BTS Enumeration Type OFF(OFF), ON(ON) OFF, ON None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ADMODE Auto Download Mode BSC6900 SET BTSAUTODLDACTINFO(Optional) Automatic downloading mode of the BTS. If the parameter is set to 0, common downloading is performed through the OML/EML. If the parameter is set to 1, besides the downloading through the OML/EML, the downloading through dynamically extending the link bandwidth can also be performed. In this case, the cell traffic of the BTS is not reserved. If the parameter is set to 2, besides the downloading through the OML/EML, the downloading through dynamically extending the link bandwidth can also be performed. In this case, the traffic on the BCCH TRX of the BTS cell is reserved. GBFD-111202O&M of BTS Enumeration Type COMMON_DLD(Common Download), QUICK_DLD1(Quick Download No Traffic), QUICK_DLD2(Quick Download Reserve BCCH) COMMON_DLD, QUICK_DLD1, QUICK_DLD2 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ADMSTAT Administrative State BSC6900 SET GCELLADMSTAT(Mandatory) Administrative state of a cell GBFD-111202O&M of BTS Enumeration Type LOCK(Lock), UNLOCK(Unlock), SHUTDOWN(Shutdown) Lock, Unlock, Shutdown None None Unlock Cell None Read & Write N (No impact on the UE in idle mode) Cell The services are disrupted until this parameter is set to Unlock. None
ADMSTAT Administrative State BSC6900 SET GTRXADMSTAT(Mandatory) Administrative state of the TRX GBFD-111202O&M of BTS Enumeration Type Lock(Lock), Unlock(Unlock), Shutdown(Shutdown) Lock, Unlock, Shutdown None None None TRX None Read & Write If the value of this parameter is modified to "Lock", forced handover is triggered to hand the ongoing services on the corresponding TRX to another TRX. Services will be disrupted if the handover fails. If the value of this parameter is modified to "Shutdown", the ongoing services are not affected but new service accesses are not allowed. TRX Services will be disrupted until the value of this parameter is changed to "Unlock". None
ADMSTAT Administrative State BSC6900 SET GTRXCHANADMSTAT(Mandatory) Administrative state of the channel GBFD-111202O&M of BTS Enumeration Type Lock(Lock), Unlock(Unlock), Shutdown(Shutdown) Lock, Unlock, Shutdown None None None Current BFD session None Read & Write If the value of this parameter is modified to "Lock", forced handover is triggered to hand the ongoing services on the corresponding channel to another channel. Services will be disrupted if the handover fails. If the value of this parameter is modified to "Shutdown", the ongoing services are not affected but new service accesses are not allowed. Channel Services will be disrupted until the value of this parameter is changed to "Unlock". None
ADTET Offset Time Adjustment End Time BSC6900 ADD AISSCFG(Optional) End time for adjusting the offset time. GBFD-118201Soft-Synchronized Network Compound Type hour, min hour{0~23}min{0~59} None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None.
ADTLOD Load Threshold of Offset Adjustment BSC6900 ADD AISSCFG(Optional) Cell load threshold for adjusting the offset time. If the load threshold is exceeded, the offset time is not adjusted. GBFD-118201Soft-Synchronized Network Interval Type 0~100 0~100 None 10 None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None.
ADTON Offset Time Adjustment Switch BSC6900 ADD AISSCFG(Mandatory) Offset Time Adjustment Switch. GBFD-118201Soft-Synchronized Network Enumeration Type OFF(OFF), ON(ON) OFF, ON None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None.
ADTST Offset Time Adjustment Start Time BSC6900 ADD AISSCFG(Optional) Start time for adjusting the offset time. GBFD-118201Soft-Synchronized Network Compound Type hour, min hour{0~23}min{0~59} None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None.
ADVALMMGRULETP Advanced Alarm Management Rule Type BSC6900 ADD BTSALMMGMRULE(Mandatory) Advanced alarm management rule type MRFD-210304Faulty Management Enumeration Type RATIORULE(Ratio Rule) RATIORULE None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ADVER1 BTS Software Version 1 BSC6900 SET BTSAUTODLDACTINFO(Optional) BTS software version 1 for automatically downloading and activating the BTS GBFD-111202O&M of BTS String Type None 1~51 characters None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ADVER2 BTS Software Version 2 BSC6900 SET BTSAUTODLDACTINFO(Optional) BTS software version 2 for automatically downloading and activating the BTS GBFD-111202O&M of BTS String Type None 1~51 characters None None None BTS This parameter can be configured only when "BTS Software Version 1" is configured. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AEC_Echo_Path_Delay AEC Echo Path Delay BSC6900 SET TCPARA(Optional) If the echo path is traced, the echo is judged and controlled according to the trace result of the echo path parameters. Otherwise, the echo is judged and controlled according to the recommended value. GBFD-115602Acoustic Echo Cancellation(AEC) Interval Type 0~600 0~600 ms None 400 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AEC_Echo_Return_Loss AEC Echo Return Loss BSC6900 SET TCPARA(Optional) This parameter is used for echo judgment and control when the echo parameters are not traced. GBFD-115602Acoustic Echo Cancellation(AEC) Interval Type 0~60 0~60 dB None 20 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AEC_Nlp_Gate AEC Nlp Gate BSC6900 SET TCPARA(Optional) If the local input voltage is lower than the value of this parameter and the remote end transmits the voice signal, the AEC function uses the comfort noise to replace the minor echo. In this case, the speech signals at low level may also be cut. GBFD-115602Acoustic Echo Cancellation(AEC) Interval Type -60~-35,0 -60~-35, 0 dBm None -48 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AEC_Path_Delay AEC Path Delay BSC6900 SET TCPARA(Optional) Extra delay due to the transmission line. This parameter should be set according to the actual conditions and is applicable to satellite transmission. GBFD-115602Acoustic Echo Cancellation(AEC) Interval Type 0~1000 0~1000 ms None 0 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AEC_SNR_Gate AEC SNR Gate BSC6900 SET TCPARA(Optional) This parameter is used to determine whether there are speech signals on the local end. If the local SNR is lower than the value of this parameter, echo control is not performed. GBFD-115602Acoustic Echo Cancellation(AEC) Interval Type 0~15 0~15 dB None 6 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AEC_Switch AEC Switch BSC6900 SET TCPARA(Optional) This parameter indicates the acoustic echo cancellation (AEC) functional switch is switched on or switched off. GBFD-115602Acoustic Echo Cancellation(AEC) Enumeration Type CLOSE(Close), OPEN(Open) CLOSE, OPEN None None CLOSE Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AECDetectThreshold AEC Detect Threshold BSC6900 SET TCPARA(Optional) Threshold for detecting the AEC performance GBFD-115602Acoustic Echo Cancellation(AEC) Interval Type 10~100 10~100 None None 90 Board If the number of echo cancellations performed by AEC exceeds "AEC Detect Threshold" within the time specified by "AEC Detect Time", the TFO is closed forcibly. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AECDetectTime AEC Detect Time BSC6900 SET TCPARA(Optional) Time for detecting the AEC performance GBFD-115602Acoustic Echo Cancellation(AEC) Interval Type 1~10 1~10 s None 4 Board If the number of echo cancellations performed by AEC exceeds "AEC Detect Threshold" within the time specified by "AEC Detect Time", the TFO is closed forcibly. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AFRDSBLCNT AFR Radio Link Timeout BSC6900 SET GCELLCCBASIC(Optional) Counter of radio link failures during an AMR full rate call. See the description of "Radio Link Timeout" in "SET GCELLCCBASIC". GBFD-115505AMR Wireless Link Timer Enumeration Type 4_Times, 8_Times, 12_Times, 16_Times, 20_Times, 24_Times, 28_Times, 32_Times, 36_Times, 40_Times, 44_Times, 48_Times, 52_Times, 56_Times, 60_Times, 64_Times 4_Times, 8_Times, 12_Times, 16_Times, 20_Times, 24_Times, 28_Times, 32_Times, 36_Times, 40_Times, 44_Times, 48_Times, 52_Times, 56_Times, 60_Times, 64_Times, step: SACCH period ms None 64_Times Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved With a good anti-interference capability, AMR codes can support a lower carrier-to-interference ratio than non-AMR codes in a same FER. When the AMR is enabled, the voice quality improves. In this case, the value of this parameter can be a little larger than that of "Radio Link Timeout".
AFRSAMULFRM AFR SACCH Multi-Frames BSC6900 SET GCELLCCBASIC(Optional) Number of SACCH multiframes during an AMR full rate call. See the description of "SACCH Multi-Frames" in "SET GCELLCCBASIC". GBFD-115505AMR Wireless Link Timer Interval Type 0~63 0~63, step: SACCH period ms None 48 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved With a good anti-interference capability, AMR codes can support a lower carrier-to-interference ratio than non-AMR codes in a same FER. When the AMR is enabled, the voice quality improves. In this case, the value of this parameter can be a little larger than that of "SACCH Multi-Frames".
AHRDSBLCNT AHR Radio Link Timeout BSC6900 SET GCELLCCBASIC(Optional) Counter of radio link failures during an AMR half rate call. See the description of "Radio Link Timeout" in "SET GCELLCCBASIC". GBFD-115505AMR Wireless Link Timer Enumeration Type 4_Times, 8_Times, 12_Times, 16_Times, 20_Times, 24_Times, 28_Times, 32_Times, 36_Times, 40_Times, 44_Times, 48_Times, 52_Times, 56_Times, 60_Times, 64_Times 4_Times, 8_Times, 12_Times, 16_Times, 20_Times, 24_Times, 28_Times, 32_Times, 36_Times, 40_Times, 44_Times, 48_Times, 52_Times, 56_Times, 60_Times, 64_Times, step: SACCH period ms None 52_Times Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved With a good anti-interference capability, AMR codes can support a lower carrier-to-interference ratio than non-AMR codes in a same FER. When the AMR is enabled, the voice quality improves. In this case, the value of this parameter can be a little larger than that of "Radio Link Timeout".
AHRSAMULFRM AHR SACCH Multi-Frames BSC6900 SET GCELLCCBASIC(Optional) Number of SACCH multiframes during an AMR half rate call. See the description of "SACCH Multi-Frames" in "SET GCELLCCBASIC". GBFD-115505AMR Wireless Link Timer Interval Type 0~63 0~63, step: SACCH period ms None 32 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved With a good anti-interference capability, AMR codes can support a lower carrier-to-interference ratio than non-AMR codes in a same FER. When the AMR is enabled, the voice quality improves. In this case, the value of this parameter can be a little larger than that of "SACCH Multi-Frames".
AID Alarm ID BSC6900 SET ALMPORT(Mandatory) Alarm ID MRFD-210304Faulty Management Interval Type 65334~65383 65334~65383 None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AID Alarm ID BSC6900 SET ALMBLKPARA(Mandatory) Alarm ID MRFD-210304Faulty Management Interval Type 1~65535 1~65535 None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
aid Alarm ID BSC6900 SET ALMLVL(Mandatory)SET ALMSHLD(Mandatory)SET BOXRPT(Mandatory) Identifier of the alarm. This parameter uniquely identifies an alarm. MRFD-210304Faulty Management Interval Type 1~65535 1~65535 None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AID Alarm ID BSC6900 ADD OBJALMSHLD(Optional) Identifier of the alarm. This parameter uniquely identifies an alarm. MRFD-210304Faulty Management Interval Type 1~65535 1~65535 None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AID Alarm ID BSC6900 SET ENVALMPARA(Mandatory) Identifier of the alarm. This parameter uniquely identifies an alarm. MRFD-210304Faulty Management Interval Type 1~65535 1~65535 None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AID Alarm ID. BSC6900 SET BTSENVALMPORT(Optional) Alarm ID GBFD-111202O&M of BTS Interval Type 65033~65533 65033~65533 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AID Alarm ID. BSC6900 ADD BTSOBJALMSHLD(Mandatory) Alarm ID MRFD-210304Faulty Management String Type None 1~1024 characters None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AIDDELAYPROTECTTIME Aiding Delay Protect Time BSC6900 SET GCELLSOFT(Optional) Delay time for mutual-aid detection on a cell after the cell is initialized. When the cell initialization has just finished, the cell is in an unstable state. Mutual-aid detection at this time may cause a mistaken decision. Therefore, this parameter is used for specifying proper delay. GBFD-113801TRX Cooperation Interval Type 1~60 1~60 min None 15 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved If this parameter is set to a greater value, TRX mutual aid may not be triggered promptly in the case of BCCH TRX failure after a cell has just been initialized. If this parameter is set to smaller value, mutual aid may be decided mistakenly.
AIDST Alarm Select Type BSC6900 ADD OBJALMSHLD(Optional) Type of alarm selection MRFD-210304Faulty Management Enumeration Type ALL(all), ONEBYONE(one by one) ALL, ONEBYONE None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AIDST Alarm Select Type BSC6900 ADD BTSOBJALMSHLD(Mandatory) Alarm selection mode MRFD-210304Faulty Management Enumeration Type ALL(all), ONEBYONE(one by one) ALL, ONEBYONE None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AInterMsgTrace A interface msg [end2end user tracing] BSC6900 SET OTHSOFTPARA(Mandatory) Whether to trace A-interface messages during end-to-end user tracing. The end-to-end tracing is conducted throughout the network. The A-interface tracing results can be obtained from the MSC or BSC. GBFD-116401End-to-End MS Signaling Tracing Enumeration Type NO(No), YES(Yes)NO, YES None None NO BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AINTFFCDISCLUEN A IF FC Discard LOC UP Enable BSC6900 SET BSCFCPARA(Optional) Whether to allow flow control for the location update services during the A interface flow control GBFD-111705GSM Flow Control Enumeration Type NO(No), YES(Yes)NO, YES None None YES BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AINTFFCDISCMOCEN A IF FC Discard MOC Enable BSC6900 SET BSCFCPARA(Optional) whether to allow flow control for the mobile-originated services during the A interface flow control GBFD-111705GSM Flow Control Enumeration Type NO(No), YES(Yes)NO, YES None None YES BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AINTFFCDISCMTCEN A IF FC Discard MTC Enable BSC6900 SET BSCFCPARA(Optional) Whether to allow flow control for the mobile-terminated services during the A interface flow control GBFD-111705GSM Flow Control Enumeration Type NO(No), YES(Yes)NO, YES None None YES BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AINTFFCDISCOSEN A IF FC Discard Other Service Enable BSC6900 SET BSCFCPARA(Optional) Whether to allow flow control for the other services including emergency call, call reestablish, and LMU services during the A interface flow control GBFD-111705GSM Flow Control Enumeration Type NO(No), YES(Yes)NO, YES None None YES BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AINTFFCEN A Interface Flow Control Enable BSC6900 SET BSCFCPARA(Optional) Whether to enable the A interface flow control mechanism in the BSC GBFD-111705GSM Flow Control Enumeration Type NO(No), YES(Yes)NO, YES None None NO BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AINTFFCMETHOD A Interface Flow Control Method BSC6900 SET BSCFCPARA(Optional) Flow control method used by the BSC. Flow control method at the Abis interface: When receiving a channel request message, the BSC begins flow control on the call according to the flow control level of the A interface. Flow control method at the A interface: When establishing an SCCP connection, the BSC begins flow control according to the flow control level of the A interface and releases part of the call. GBFD-111705GSM Flow Control Enumeration Type ABIS(Abis), A(A) ABIS, A None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AINTFFCRSRATE1 A IF FC Service Rate in Level 1 BSC6900 SET BSCFCPARA(Optional) Rate of discarded services in level 1 of the A interface flow control GBFD-111705GSM Flow Control Interval Type 0~100 0~100 per cent None 5 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AINTFFCRSRATE2 A IF FC Service Rate in Level 2 BSC6900 SET BSCFCPARA(Optional) Rate of discarded services in level 2 of the A interface flow control GBFD-111705GSM Flow Control Interval Type 0~100 0~100 per cent None 5 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AINTFFCRSRATE3 A IF FC Service Rate in Level 3 BSC6900 SET BSCFCPARA(Optional) Rate of discarded services in level 3 of the A interface flow control GBFD-111705GSM Flow Control Interval Type 0~100 0~100 per cent None 5 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AINTFFCRSRATE4 A IF FC Service Rate in Level 4 BSC6900 SET BSCFCPARA(Optional) Rate of discarded services in level 4 of the A interface flow control GBFD-111705GSM Flow Control Interval Type 0~100 0~100 per cent None 10 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AINTFFCRSRATE5 A IF FC Service Rate in Level 5 BSC6900 SET BSCFCPARA(Optional) Rate of discarded services in level 5 of the A interface flow control GBFD-111705GSM Flow Control Interval Type 0~100 0~100 per cent None 10 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AINTFFCRSRATE6 A IF FC Service Rate in Level 6 BSC6900 SET BSCFCPARA(Optional) Rate of discarded services in level 6 of the A interface flow control GBFD-111705GSM Flow Control Interval Type 0~100 0~100 per cent None 10 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ALARMENABLE Common Alarm Switch Enabled BSC6900 SET BTSRXUBP(Optional) Whether to enable the common alarm switches [1-2]. This parameter consists of two bits, each of which indicates whether the corresponding Boolean alarm is enabled or not. MRFD-210304Faulty Management Bit Field Type NO1DISABLE, NO2DISABLE NO1DISABLE, NO2DISABLE None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ALARMENABLEX4 Common Alarm Switch Enabled BSC6900 SET BTSRXUBP(Optional) Whether to enable the common alarm switches [1-4]. This parameter consists of four bits, each of which indicates whether the corresponding Boolean alarm is enabled or not. MRFD-210304Faulty Management Bit Field Type NO1DISABLE, NO2DISABLE, NO3DISABLE, NO4DISABLE NO1DISABLE, NO2DISABLE, NO3DISABLE, NO4DISABLE None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ALC_Fix_Gain ALC Fix Gain BSC6900 SET TCPARA(Optional) Fixed gain value in fixed gain mode GBFD-115601Automatic Level Control (ALC) Interval Type -12~12 -12~12 dB None 6 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ALC_Fix_Target_Level ALC Fix Target Level BSC6900 SET TCPARA(Optional) Target level in fixed level mode GBFD-115601Automatic Level Control (ALC) Interval Type -23~-4 -23~-4 dBm None -18 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ALC_Max_Gain ALC Max Gain BSC6900 SET TCPARA(Optional) This parameter restrains the maximum gain to the input signal. It is valid only when "ALC Mode" is "FIXEDLEVEL" or "ADAPTIVE". If the parameter is set to a small value, it may affect the conformance to the target level. GBFD-115601Automatic Level Control (ALC) Interval Type 3~12 3~12 dB None 6 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ALC_Max_Target_Level ALC Max Target Level BSC6900 SET TCPARA(Optional) Maximum target level in adaptive ALC mode GBFD-115601Automatic Level Control (ALC) Interval Type -23~-4 -23~-4 dBm None -4 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ALC_Min_Target_Level ALC Min Target Level BSC6900 SET TCPARA(Optional) Mimumum target level in adaptive ALC mode GBFD-115601Automatic Level Control (ALC) Interval Type -23~-4 -23~-4 dBm None -23 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ALC_Mode ALC Mode BSC6900 SET TCPARA(Optional) ALC level control mode GBFD-115601Automatic Level Control (ALC) Enumeration Type FIXEDLEVEL(Fixed level mode), ADAPTIVE(Adaptive mode), FIXEDGAIN(Fixed gain mode) FIXEDLEVEL, ADAPTIVE, FIXEDGAIN None None FIXEDLEVEL Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ALC_Switch ALC Switch BSC6900 SET TCPARA(Optional) Whether to enable the adaptive level control (ALC) function GBFD-115601Automatic Level Control (ALC) Enumeration Type CLOSE(Close), OPEN(Open) CLOSE, OPEN None None CLOSE Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ALIVERETRY Alive Retry BSC6900 SET BSCNSPARA(Optional) Retry times after the timer for the reply from the peer expires during the NSVC live test. If the reply is not received after the system resends the message according to retry times, the NSVC is regarded as faulty. GBFD-510002Gb Over FR Interval Type 5~15 5~15 None None 5 BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ALIVETIMER Alive Timer BSC6900 SET BSCNSPARA(Optional) Duration of the timer to wait for the reply from the peer during the NSVC live test. GBFD-510002Gb Over FR Interval Type 1~255 1~255 s None 3 BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AllBw Bandwidth BSC6900 ADD RSCGRP(Mandatory) It is the bandwidth when the " transmission resource group type " is IP and the " bandwidth mode " is HALF_DUPLEX. None None Interval Type 0~4000000 0~4000000 kbit/s None None Transmission resource group When "BWMODE" in "ADD RSCGRP" is set to HALF_DUPLEX, this parameter is valid;if the "BWMODE" in "ADD RSCGRP" of upper class and lower class RSCGRP is set to HALF_DUPLEX, the "AllBw" in "ADD RSCGRP" of upper class RSCGRP can not less than the "AllBwE" in "ADD RSCGRP" of lower class RSCGRP;The "AllBw" in "ADD RSCGRP" of upper class RSCGRP can not less than the sum of "TxBw" and "RxBw" in "ADD RSCGRP" of lower class RSCGRP. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ALLOCDIFFTRX Resource Reallocation to Different Trx BSC6900 SET BSCPSSOFTPARA(Optional) Whether to reassign the TBF for a different Trx. GBFD-114101GPRS Enumeration Type NOTALLOW(Not Allow), ALLOW(Allow) NOTALLOW, ALLOWNone None ALLOW BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ALLOCSINGLEPDCHFORSIGNALLING Allocate One PDCH for Signalling Data BSC6900 SET GCELLPSCHM(Optional) When this parameter is set to ON, the GMM/SM signalling service is assigned only one PDCH; otherwise, the GMM/SM signalling service is assigned one or more PDCHs as required. None None Enumeration Type OFF(OFF), ON(ON) OFF, ON None None OFF Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ALLOWAMRHALFRATEUSERPERC Ratio of AMR-HR BSC6900 SET GCELLCHMGBASIC(Optional) Maximum percentage of the number of AMR half rate channels in the total number of channels in the cell. If the percentage is equal to or greater than this parameter, no AMR half rate channel can be further assigned.Total number of channels = number of half rate channels + number of full rate channels x 2 GBFD-111005Enhanced Channel Assignment Algorithm Interval Type 0~100 0~100 per cent None 100 Cell The following condition must be met: "ALLOWAMRHALFRATEUSERPERC" <= "ALLOWHALFRATEUSERPERC". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ALLOWEDADAMULTIPLEX Allow EDA Multiplex BSC6900 SET BSCPSSOFTPARA(Optional) Whether to allow EDA multiplex. not allow EDA Multiplex: the TBF of the EDA cannot be multiplexed with other TBR; allow EDA Multiplex: the TBF of the EDA can be multiplexed with other TBF. GBFD-119401Extended Dynamic Allocation(EDA) Enumeration Type NOTALLOW(Not Allow), ALLOW(Allow) NOTALLOW, ALLOWNone None NOTALLOW BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter is valid only when "SUPPORTEDA" is set to SUPPORT.
ALLOWEDMEASRPTMISSEDNUM Allowed Measure Report Missed Number BSC6900 SET GCELLNC2PARA(Optional) Number of allowed measure report missed. If the number of allowed measure report missed exceeds this value, the previous measure report is invalid. GBFD-116201Network-Controlled Cell Reselection (NC2) Interval Type 0~16 0~16 None None 4 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ALLOWHALFRATEUSERPERC Ratio of TCHH BSC6900 SET GCELLCHMGBASIC(Optional) Maximum percentage of the number of half rate channels in the total number of channels in the cell. If the percentage is equal to or greater than this parameter, no half rate channel can be further assigned.Total number of channels = number of half rate channels + number of full rate channels x 2 GBFD-111005Enhanced Channel Assignment Algorithm Interval Type 0~100 0~100 per cent None 100 Cell The following condition must be met: "ALLOWHALFRATEUSERPERC" >= "ALLOWAMRHALFRATEUSERPERC". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ALLTSTYPE Timeslot Type BSC6900 ADD PBE1T1(Optional) All timeslot types of the E1/T1 of the Pb interface is set to CIC or NULL. GBFD-111203O&M of BSC Enumeration Type ALLCIC(Set all Timeslots CIC), ALLNULL(Set all Timeslots Null) ALLCIC, ALLNULL None ALLCIC ALLCIC PBE1T1 None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ALLTSTYPE Timeslot Type BSC6900 ADD AE1T1(Mandatory) Value ALLCIC indicates that all E1/T1 timeslots on the A interface are of CIC type. Value ALLNULL indicates that all E1/T1 timeslots on the A interface are of null type. GBFD-111803A Interface Circuit Management Enumeration Type ALLCIC(Set all Timeslots CIC), ALLNULL(Set all Timeslots Null) ALLCIC, ALLNULL None None ALLCIC E1/T1 linkNone Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ALMD0 Feed Tri. 0 TMA Low Current Alm Thred. BSC6900 SET BTSDATUBP(Optional) If the feed current of the TMA on tributary 0 is smaller than the value of this parameter, the TMA Low Temperature alarm is triggered. MRFD-210304Faulty Management Interval Type 0~2000 0~2000 mA None 30 BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ALMD1 Feed Tri. 1 TMA Low Current Alm Thred. BSC6900 SET BTSDATUBP(Optional) If the feed current of the TMA on tributary 1 is smaller than the value of this parameter, the TMA Low Temperature alarm is triggered. MRFD-210304Faulty Management Interval Type 0~2000 0~2000 mA None 30 BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ALMD2 Feed Tri. 2 TMA Low Current Alm Thred. BSC6900 SET BTSDATUBP(Optional) If the feed current of the TMA on tributary 2 is smaller than the value of this parameter, the TMA Low Temperature alarm is triggered. MRFD-210304Faulty Management Interval Type 0~2000 0~2000 mA None 30 BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ALMD3 Feed Tri. 3 TMA Low Current Alm Thred. BSC6900 SET BTSDATUBP(Optional) If the feed current of the TMA on tributary 3 is smaller than the value of this parameter, the TMA Low Temperature alarm is triggered. MRFD-210304Faulty Management Interval Type 0~2000 0~2000 mA None 30 BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ALMD4 Feed Tri. 4 TMA Low Current Alm Thred. BSC6900 SET BTSDATUBP(Optional) If the feed current of the TMA on tributary 4 is smaller than the value of this parameter, the TMA Low Temperature alarm is triggered. MRFD-210304Faulty Management Interval Type 0~2000 0~2000 mA None 30 BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ALMD5 Feed Tri. 5 TMA Low Current Alm Thred. BSC6900 SET BTSDATUBP(Optional) If the feed current of the TMA on tributary 5 is smaller than the value of this parameter, the TMA Low Temperature alarm is triggered. MRFD-210304Faulty Management Interval Type 0~2000 0~2000 mA None 30 BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ALMDISACDUR Alarm Disappear Accumulate Duration BSC6900 ADD BTSALMMGMRULE(Mandatory) Alarm clearance accumulated failure duration MRFD-210304Faulty Management Interval Type 0~65535 0~65535 s None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ALMENABLE Alarm Enable Flag BSC6900 SET BTSAPMUBP(Optional)SET BTSDPMUBP(Optional) Whether the configuration of alarm parameters is allowed.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. MRFD-210304Faulty Management Enumeration Type NO(NO), YES(YES) NO, YES None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AlmFlag1 Alarm Shield Flag 1 BSC6900 SET BTSALM(Optional) Whether to shield Boolean alarms. Each bit indicates whether to shield the alarm associated with a specific Boolean. If the bit is set to 1, the Boolean alarm is not shielded. If the bit is set to 0, the Boolean alarm is shielded. Low bit correspond to low port. GBFD-111202O&M of BTS Interval Type 0~255 0~255 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AlmFlag2 Alarm Shield Flag 2 BSC6900 SET BTSALM(Optional) Whether to shield Boolean alarms. Each bit indicates whether to shield the alarm associated with a specific Boolean. If the bit is set to 1, the Boolean alarm is not shielded. If the bit is set to 0, the Boolean alarm is shielded. Low bit correspond to low port. GBFD-111202O&M of BTS Interval Type 0~255 0~255 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AlmFlag3 Alarm Shield Flag 3 BSC6900 SET BTSALM(Optional) Whether to shield Boolean alarms. Each bit indicates whether to shield the alarm associated with a specific Boolean. If the bit is set to 1, the Boolean alarm is not shielded. If the bit is set to 0, the Boolean alarm is shielded. Low bit correspond to low port. GBFD-111202O&M of BTS Interval Type 0~255 0~255 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AlmFlag4 Alarm Shield Flag 4 BSC6900 SET BTSALM(Optional) Whether to shield Boolean alarms. Each bit indicates whether to shield the alarm associated with a specific Boolean. If the bit is set to 1, the Boolean alarm is not shielded. If the bit is set to 0, the Boolean alarm is shielded. Low bit correspond to low port. This parameter can be configured only when "BTSTYPE" is BTS3006C or BTS3002E. GBFD-111202O&M of BTS Interval Type 0~255 0~255 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AlmFlag5 Alarm Shield Flag 5 BSC6900 SET BTSALM(Optional) Whether to shield Boolean alarms. Each bit indicates whether to shield the alarm associated with a specific Boolean. If the bit is set to 1, the Boolean alarm is not shielded. If the bit is set to 0, the Boolean alarm is shielded. Low bit correspond to low port. This parameter can be configured only when "BTSTYPE" is BTS3006C or BTS3002E. GBFD-111202O&M of BTS Interval Type 0~255 0~255 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AlmId Alarm ID BSC6900 SET BTSALMFLASHTHD(Mandatory) ID of the intermittent alarm. MRFD-210304Faulty Management Interval Type 0~65534 0~65534 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ALMID Alarm ID. BSC6900 ADD BTSALMMGMRULE(Mandatory) Alarm ID MRFD-210304Faulty Management Interval Type 0~65535 0~65535 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ALMLMTDOWN Lower Alarm BSC6900 SET BTSDGPSBP(Optional) If the input current of the antenna feeder is smaller than the value of this parameter, an alarm related to the GPS antenna is reported. MRFD-210304Faulty Management Interval Type 0~15 0~15 mA None 10 BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ALMLMTUP1 Upper Alarm BSC6900 SET BTSDGPSBP(Optional) If the input current of the antenna feeder is greater than the value of this parameter and "GPS or RGPS" is set to "GPS", an alarm related to the GPS antenna is reported. MRFD-210304Faulty Management Interval Type 45~155 45~155 mA None 100 BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ALMLMTUP2 Upper Alarm BSC6900 SET BTSDGPSBP(Optional) If the input current of the antenna feeder is greater than the value of this parameter and "GPS or RGPS" is set to "RGPS", an alarm related to the GPS antenna is reported. MRFD-210304Faulty Management Interval Type 125~175 125~175 mA None 150 BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ALMOCACDUR Alarm Occurrence Accumulate Duration BSC6900 ADD BTSALMMGMRULE(Mandatory) Accumulated alarm occurrence duration MRFD-210304Faulty Management Interval Type 0~65535 0~65535 s None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AlmOccurAccuTimeHThd Alarm Occur Accumulative Time Threshold BSC6900 SET BTSALMFLASHTHD(Optional) Alarm Occur Accumulative Time refers to the percentage of the alarm occurrence accumulative time to "Flash Statis Alarm Raise Time Window". If the alarm occurrence accumulative duration is greater than the parameter value, the BTS fault statistical alarm is reported. For example, if the parameter value is 60, it indicates that Alarm Occur Accumulative Time = "Flash Statis Alarm Raise Time Window" x 60%. If the parameter value is 0, no statistics is collected. MRFD-210304Faulty Management Interval Type 0~100 0~100 per cent 0 None BTS The recommended value of this parameter is greater than twice "Alarm Clear Accumulative Time Threshold" and greater than twice "Flash Alarm Occur Threshold". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AlmOccurAccuTimeLThd Alarm Clear Accumulative Time Threshold BSC6900 SET BTSALMFLASHTHD(Optional) Alarm Clear Accumulative Time refers to the percentage of the alarm clearance accumulative time to "Flash Statis Alarm Clear Time Window". If the alarm clearance accumulative duration is greater than this threshold, the BTS fault statistical alarm is cleared. For example, if the parameter value is 30, it indicates that Alarm Clear Accumulative Time = "Flash Statis Alarm Clear Time Window" x 30%. If the parameter value is 0, no statistics is collected. MRFD-210304Faulty Management Interval Type 0~100 0~100 per cent 0 None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AlmOccurTimesHThd Alarm Occur Times Threshold BSC6900 SET BTSALMFLASHTHD(Optional) If the number of alarm flashes exceeds the value of this parameter within the time specified by "Flash Statis Alarm Raise Time Window", the BTS Statistical Alarm is generated. If this parameter is set to 0, the statistics of the BTS alarm flashes is not collected. MRFD-210304Faulty Management Interval Type 0~250 0~250 None 0 None BTS The recommended value of this parameter is greater than twice "Alarm Clear Times Threshold". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AlmOccurTimesLThd Alarm Clear Times Threshold BSC6900 SET BTSALMFLASHTHD(Optional) If the number of alarm flashes is smaller than the value of this parameter within the time specified by "Flash Statis Alarm Clear Time Window", the BTS Statistical Alarm is cleared. If this parameter is set to 0, the statistics of the BTS alarm flashes is not collected. MRFD-210304Faulty Management Interval Type 0~250 0~250 None 0 None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ALMPARACFGFLAG Alarm Parameter Configuration Enabled BSC6900 SET BTSDHEUBP(Optional) Whether the configuration of alarm parameters is allowed The value "YES" indicates that the configuration is allowed, and the value "NO" indicates that the configuration is not allowed. MRFD-210304Faulty Management Enumeration Type NO(NO), YES(YES) NO, YES None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
almtp Alarm Type BSC6900 EXP ALMLOG(Optional)STAALMLOG(Optional) Type of the alarm. The alarm can be a fault alarm or an event alarm. MRFD-210304Faulty Management Enumeration Type flt(Fault), evt(Event), all(All) flt, evt, all None all all RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ALPHA ALPHA BSC6900 SET GCELLPSPWPARA(Optional) It is used to perform open loop power control. Alpha parameter is used by the MS to calculate the output power PCH of the uplink PDCH. This parameter is used to set the reduced class of the Tx power of the MS in the correspondence with the path loss when the GPRS dynamic power control is enabled. GBFD-119115Power Control Enumeration Type 0(0.0), 1(0.1), 2(0.2), 3(0.3), 4(0.4), 5(0.5), 6(0.6), 7(0.7), 8(0.8), 9(0.9), 10(1.0) 0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10 None None 6 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ALTIDECI Antenna Altitude Decimal Part BSC6900 SET GCELLLCS(Optional) Decimal part of the antenna altitude GBFD-115402BSS-Based LCS (Cell ID + TA) Interval Type 0~9 0~9, step: 0.1 m None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ALTITUDE Antenna Altitude Int Part BSC6900 SET GCELLLCS(Optional) Integer part of the antenna altitude GBFD-115402BSS-Based LCS (Cell ID + TA) Interval Type 0~6553 0~6553 m None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
alvl Alarm Severity BSC6900 EXP ALMLOG(Optional) Alarm severity. One or more severities can be selected. By default, all severities are selected. MRFD-210304Faulty Management Bit Field Type Critical, Major, Minor, Warning Critical, Major, Minor, Warning None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
alvl Alarm Severity BSC6900 SET ALMLVL(Mandatory)SET ALMSCRN(Mandatory)SET ENVALMPARA(Optional) Alarm severity. One or more severities can be selected. By default, all severities are selected. MRFD-210304Faulty Management Enumeration Type Critical(Critical), Major(Major), Minor(Minor), Warning(Warning) Critical, Major, Minor, Warning None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AMPC0 Feed Tri. 0 TMA Configuration BSC6900 SET BTSDATUBP(Optional) Whether to supply power to the TMA on tributary 0 GBFD-111202O&M of BTS Enumeration Type DISABLED(Disabled), ENABLED(Enabled) DISABLED, ENABLEDNone None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AMPC1 Feed Tri. 1 TMA Configuration BSC6900 SET BTSDATUBP(Optional) Whether to supply power to the TMA on tributary 1 GBFD-111202O&M of BTS Enumeration Type DISABLED(Disabled), ENABLED(Enabled) DISABLED, ENABLEDNone None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AMPC2 Feed Tri. 2 TMA Configuration BSC6900 SET BTSDATUBP(Optional) Whether to supply power to the TMA on tributary 2 GBFD-111202O&M of BTS Enumeration Type DISABLED(Disabled), ENABLED(Enabled) DISABLED, ENABLEDNone None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AMPC3 Feed Tri. 3 TMA Configuration BSC6900 SET BTSDATUBP(Optional) Whether to supply power to the TMA on tributary 3 GBFD-111202O&M of BTS Enumeration Type DISABLED(Disabled), ENABLED(Enabled) DISABLED, ENABLEDNone None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AMPC4 Feed Tri. 4 TMA Configuration BSC6900 SET BTSDATUBP(Optional) Whether to supply power to the TMA on tributary 4 GBFD-111202O&M of BTS Enumeration Type DISABLED(Disabled), ENABLED(Enabled) DISABLED, ENABLEDNone None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AMPC5 Feed Tri. 5 TMA Configuration BSC6900 SET BTSDATUBP(Optional) Whether to supply power to the TMA on tributary 5 GBFD-111202O&M of BTS Enumeration Type DISABLED(Disabled), ENABLED(Enabled) DISABLED, ENABLEDNone None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AMRBTSPWRNUM AMR BTS PC Class BSC6900 SET GCELLPWR2(Optional) Maximum degree by which the BSC can control the power of the AMR BTS dynamically GBFD-115503AMR Power Control Interval Type 1~16 1~16, step:2 dB None 16 Cell This parameter is valid when "PWRCTRLSW" in the "SET GCELLPWRBASIC" command is set to PWR2. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AMRCALLPCALLOWED Allow III Power Control For AMR BSC6900 SET GCELLPWR3(Optional) Whether to enable the III power control algorithm for AMR calls. If enabled, power control is performed on AMR calls. GBFD-117601HUAWEI III Power Control Algorithm Enumeration Type OFF(Not Allowed), ON(Allowed) OFF, ON None None ON Cell This parameter is valid only when "PWRCTRLSW" in "SET GCELLPWRBASIC" is set to PWR3. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AMRDADTHAW AMR Downlink Adaptive Threshold Allowed BSC6900 SET GCELLCCAMR(Optional) Whether to enable the adaptive adjustment function of AMR downlink threshold. After this function is enabled, the BTS estimates the long-term voice quality (indicated by the long-term FER(frame erase ratio)) and compares the estimated result with the specified target voice quality. If the estimated result does not conform to the target voice quality, it indicates that the current AMR handover threshold may not be the best for the current radio conditions. In this case, the BSC adjust threshold adaptively according to the relation between the estimated voice quality and the target voice quality. GBFD-115506AMR Coding Rate Threshold Adaptive Adjustment Enumeration Type NO(No), YES(Yes)NO, YES None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AMRDLLEVFTLEN AMR Filter Length for DL RX_LEV BSC6900 SET GCELLPWR2(Optional) Number of measurement reports sampled for averaging downlink AMR signal strength. A single measurement report may not reflect the actual network situations accurately. Therefore, the BSC needs to average the measured values in several successive measurement reports to reflect the radio environment. GBFD-115503AMR Power Control Interval Type 1~20 1~20, step:480 for TCH and 470 for SDCCH ms None 5 Cell This parameter is valid when "PWRCTRLSW" in the "SET GCELLPWRBASIC" command is set to PWR2. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AMRDLPREDLEND AMR DL MR. Number Predicted BSC6900 SET GCELLPWR2(Optional) Number of downlink AMR measurement reports that the BSC predicts. The BSC takes a while to confirm the power control effect of a power control command. Thus, the BSC makes a power control decision based on a measurement report that lags behind the changes in the receive level and quality instead of reflecting the real-time radio environment. As a result, the power control is late.To prevent late power control to a certain degree, the power control algorithm involves a measurement report prediction filter. The BSC can sample several downlink measurement reports in a short time and then weight them to predict future N measurement reports.This parameter specifies the number N. GBFD-115503AMR Power Control Interval Type 0~3 0~3 None None 0 Cell This parameter is valid when "PWRCTRLSW" in the "SET GCELLPWRBASIC" command is set to PWR2 and "DNPCEN" in the "SET GCELLBASICPARA" command is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AMRDLQHTHRED AMR DL Qual. Upper Threshold BSC6900 SET GCELLPWR2(Optional) Quality level threshold for decreasing downlink AMR signal power. If the BTS transmits AMR signals at a quality level less than "AMR DL Qual. Upper Threshold", the BSC decreases the power of the BTS. If (downlink receive level - "AMR MAX Down Adj. PC Value by Qual.") < "AMR DL RX_LEV Lower Threshold", however, the BSC does not adjust the transmit power. GBFD-115503AMR Power Control Interval Type 0~7 0~7 None None 0 Cell This parameter is valid only when "PWRCTRLSW" in "SET GCELLPWRBASIC" is set to PWR2. The following condition must be met: "AMRDLQLTHRED" >= "AMRDLQHTHRED". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AMRDLQLTHRED AMR DL Qual. Lower Threshold BSC6900 SET GCELLPWR2(Optional) Quality level threshold for increasing downlink AMR signal power. If the BTS transmits AMR signals at a quality level greater than "AMR DL Qual. Lower Threshold", the BSC increases the power of the BTS. If (downlink receive level + "AMR MAX Up Adj. PC Value by Qual.") > "AMR DL RX_LEV Upper Threshold", however, the BSC does not adjust the transmit power. GBFD-115503AMR Power Control Interval Type 0~7 0~7 None None 3 Cell This parameter is valid only when "PWRCTRLSW" in "SET GCELLPWRBASIC" is set to PWR2. The following condition must be met: "AMRDLQLTHRED" >= "AMRDLQHTHRED". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AMRDLQUAFTLEN AMR Filter Length for DL Qual. BSC6900 SET GCELLPWR2(Optional) Number of measurement reports sampled for averaging downlink AMR signal quality. A single measurement report may not reflect the actual network situations accurately. Therefore, the BSC needs to average the measured values in several successive measurement reports to reflect the radio environment. GBFD-115503AMR Power Control Interval Type 1~20 1~20, step:480 for TCH and 470 for SDCCH ms None 5 Cell This parameter is valid when "PWRCTRLSW" in the "SET GCELLPWRBASIC" command is set to PWR2. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AMRDLQUALBADTRIG AMR DL Qual Bad Trig Threshold BSC6900 SET GCELLPWR2(Optional) During downlink power control, if the downlink receive quality level is equal to or greater than this threshold, "AMR DL RX_LEV Upper Threshold" is increased by "AMR DL Qual Bad UpLEVDiff" to further increase the expected downlink power level. GBFD-115503AMR Power Control Interval Type 0~7 0~7 None None 2 Cell This parameter is valid when "PWRCTRLSW" in the "SET GCELLPWRBASIC" command is set to PWR2. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AMRDLQUALBADUPLEV AMR DL Qual Bad UpLEVDiff BSC6900 SET GCELLPWR2(Optional) During downlink power control, if the downlink receive quality level is equal to or greater than "AMR DL Qual Bad Trig Threshold", "AMR DL RX_LEV Upper Threshold" is increased by "AMR DL Qual Bad UpLEVDiff" to further increase the expected downlink power level. GBFD-115503AMR Power Control Interval Type 0~63 0~63 dB None 8 Cell This parameter is valid when "PWRCTRLSW" in the "SET GCELLPWRBASIC" command is set to PWR2. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AMRDLSSHTHRED AMR DL RX_LEV Upper Threshold BSC6900 SET GCELLPWR2(Optional) Upper threshold for downlink AMR signal strength.If the downlink received AMR signal level is greater than this threshold, a power decrease is computed. Then, the power is decreased by the least of the power decrease, maximum power adjustment step allowed by the quality zone to which the received signal quality belongs, and "AMR MAX Down Adj. PC Value by Qual.".Power decrease = downlink received signal level - ("AMR DL RX_LEV Upper Threshold" + "AMR DL RX_LEV Lower Threshold")/2The maximum power adjustment step allowed by the quality zone is chosen from "AMR MAX Down Adj. Value Qual. Zone 0", "AMR MAX Down Adj. Value Qual. Zone 1", and "AMR MAX Down Adj. Value Qual. Zone 2" according to the quality zone. GBFD-115503AMR Power Control Interval Type 0~63 0~63 dB None 33 Cell This parameter is valid only when "PWRCTRLSW" in "SET GCELLPWRBASIC" is set to PWR2. The following condition must be met: "AMRDLSSHTHRED" >= "AMRDLSSLTHRED". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AMRDLSSLTHRED AMR DL RX_LEV Lower Threshold BSC6900 SET GCELLPWR2(Optional) Lower threshold for downlink AMR signal strength.If the downlink received AMR signal level is less than this threshold, a power increase is computed. Then, the power is increased by the least of the power increase, "AMR MAX Up Adj. PC Value by RX_LEV", and "AMR MAX Up Adj. PC Value by Qual.".Power increase = ("AMR DL RX_LEV Upper Threshold" + "AMR DL RX_LEV Lower Threshold")/2 - downlink received signal level. GBFD-115503AMR Power Control Interval Type 0~63 0~63 dB None 25 Cell This parameter is valid only when "PWRCTRLSW" in "SET GCELLPWRBASIC" is set to PWR2. The following condition must be met: "AMRDLSSHTHRED" >= "AMRDLSSLTHRED". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AMRFULLTOHALFHOALLOW AMR F-H Ho Allowed BSC6900 SET GCELLHOBASIC(Optional) Whether to enable the algorithm for the load-based AMR handover between full rate and half rate GBFD-510501HUAWEI II Handover Enumeration Type NO(No), YES(Yes)NO, YES None None NO Cell This parameter is valid only when "HOCTRLSWITCH" is set to HOALGORITHM2. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AMRFULLTOHALFHOATCBADJSTEP AMR F-H Ho ATCB Adjust Step BSC6900 SET GCELLHOBASIC(Optional) With "F-H Ho Period" and the duration for triggering handover from full rate to half rate, this parameter determines the current ATCB offset by which to choose the MSs to undergo handover from full rate to half rate.ATCB offset = (duration for triggering handover from full rate to half rate/"F-H Ho Period" + 1) x "AMR F-H Ho ATCB Adjust Step" GBFD-510501HUAWEI II Handover Interval Type 0~255 0~255 dB None 3 Cell This parameter is valid only when "HOCTRLSWITCH" is set to HOALGORITHM2 and "AMRFULLTOHALFHOALLOW" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AMRFULLTOHALFHOATCBTHRESH AMR F-H Ho ATCB Threshold BSC6900 SET GCELLHOBASIC(Optional) ATCB threshold for the AMR handover from full rate to half rate. If the ATCB of an AMR full rate call is equal to or greater than this threshold, the AMR call is handed over from full rate to half rate. GBFD-510501HUAWEI II Handover Interval Type 0~255 0~255 dB None 20 Cell This parameter is valid only when "HOCTRLSWITCH" is set to HOALGORITHM2 and "AMRFULLTOHALFHOALLOW" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AMRFULLTOHALFHOPATHADJSTEP AMR F-H Ho Pathloss Adjust Step BSC6900 SET GCELLHOBASIC(Optional) With "F-H Ho Period" and the duration for triggering handover from full rate to half rate, this parameter determines the current path loss offset by which to choose the MSs to undergo handover from full rate to half rate.Path loss offset = (duration for triggering handover from full rate to half rate/"F-H Ho Period" + 1) x "AMR F-H Ho Pathloss Adjust Step" GBFD-510501HUAWEI II Handover Interval Type 0~255 0~255 dB None 5 Cell This parameter is valid only when "HOCTRLSWITCH" is set to HOALGORITHM2 and "AMRFULLTOHALFHOALLOW" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AMRFULLTOHALFHOPATHTHRESH AMR F-H Ho Pathloss Threshold BSC6900 SET GCELLHOBASIC(Optional) Path loss threshold for the AMR handover from full rate to half rate. If the path loss of an AMR full rate call is equal to or less than this threshold, the AMR call is handed over from full rate to half rate. GBFD-510501HUAWEI II Handover Interval Type 0~255 0~255 dB None 100 Cell This parameter is valid only when "HOCTRLSWITCH" is set to HOALGORITHM2 and "AMRFULLTOHALFHOALLOW" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AMRFULLTOHALFHOQUALTHRESH AMR F-H Ho Qual. Threshold BSC6900 SET GCELLHOBASIC(Optional) Quality threshold for the AMR handover from full rate to half rate. If the uplink and downlink receive quality levels of an AMR full rate call are equal to or less than this threshold, the AMR call is handed over from full rate to half rate. GBFD-510501HUAWEI II Handover Interval Type 0~7 0~7 None None 0 Cell This parameter is valid only when "HOCTRLSWITCH" is set to HOALGORITHM2 and "AMRFULLTOHALFHOALLOW" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AMRFULLTOHALFHOTHRESH AMR F-H Traffic Threshold BSC6900 SET GCELLHOBASIC(Optional) Load threshold for the AMR handover from full rate to half rate. If the cell load is greater than this threshold, the AMR full rate calls are handed over to half rate. GBFD-510501HUAWEI II Handover Interval Type 0~100 0~100 per cent None 75 Cell This parameter is valid only when "HOCTRLSWITCH" is set to HOALGORITHM2 and "AMRFULLTOHALFHOALLOW" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AMRHALFTOFULLHOATCBTHRESH AMR H-F Ho ATCB Threshold BSC6900 SET GCELLHOBASIC(Optional) ATCB threshold for the AMR handover from half rate to full rate. If the ATCB of an AMR half rate call is less than this threshold, the AMR call is handed over from half rate to full rate. GBFD-510501HUAWEI II Handover Interval Type 0~255 0~255 dB None 4 Cell This parameter is valid only when "HOCTRLSWITCH" is set to HOALGORITHM2 and "AMRFULLTOHALFHOALLOW" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AMRHALFTOFULLHOPATHTHRESH AMR H-F Ho Pathloss Threshold BSC6900 SET GCELLHOBASIC(Optional) Path loss threshold for the AMR handover from half rate to full rate. If the path loss of an AMR half rate call is greater than this threshold, the AMR call is handed over from half rate to full rate. GBFD-510501HUAWEI II Handover Interval Type 0~255 0~255 dB None 108 Cell This parameter is valid only when "HOCTRLSWITCH" is set to HOALGORITHM2 and "AMRFULLTOHALFHOALLOW" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AMRHALFTOFULLHOQUALALLOW AMR H-F Qaul. Ho Allowed BSC6900 SET GCELLHOBASIC(Optional) Whether to enable the algorithm for the uplink and downlink receive quality based AMR handover from half rate to full rate GBFD-510501HUAWEI II Handover Enumeration Type NO(No), YES(Yes)NO, YES None None NO Cell This parameter is valid only when "HOCTRLSWITCH" is set to HOALGORITHM2 and "AMRFULLTOHALFHOALLOW" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AMRHALFTOFULLHOQUALTHRESH AMR H-F Ho Qual. Threshold BSC6900 SET GCELLHOBASIC(Optional) Quality threshold for the AMR handover from half rate to full rate. If the receive quality level of an AMR half rate call is greater than this threshold, the AMR call is handed over from half rate to full rate. GBFD-510501HUAWEI II Handover Interval Type 0~7 0~7 None None 3 Cell This parameter is valid only when "HOCTRLSWITCH" is set to HOALGORITHM2 and "AMRFULLTOHALFHOALLOW" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AMRHALFTOFULLHOTHRESH AMR H-F Traffic Threshold BSC6900 SET GCELLHOBASIC(Optional) Load threshold for the AMR handover from half rate to full rate. If the cell load is less than this threshold, the AMR half rate calls are handed over to full rate. GBFD-510501HUAWEI II Handover Interval Type 0~100 0~100 per cent None 15 Cell This parameter is valid only when "HOCTRLSWITCH" is set to HOALGORITHM2 and "AMRFULLTOHALFHOALLOW" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AMRMAXADJPCVAL AMR MAX Up Adj. PC Value by Qual. BSC6900 SET GCELLPWR2(Optional) Maximum step by which the power can be increased according to received signal quality GBFD-115503AMR Power Control Interval Type 0~32 0~32 dB None 8 Cell This parameter is valid when "PWRCTRLSW" in the "SET GCELLPWRBASIC" command is set to PWR2. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AMRMAXSTEP0 AMR MAX Down Adj. Value Qual. Zone 0 BSC6900 SET GCELLPWR2(Optional) Maximum step by which the power can be decreased when the received signal quality belongs to quality zone 0. Huawei power control algorithm generation II classifies the received signal quality into three quality zones. The maximum step by which the power can be decreased according to signal level varies according to the quality zones. GBFD-115503AMR Power Control Interval Type 0~30 0~30 dB None 2 Cell This parameter is valid when "PWRCTRLSW" in the "SET GCELLPWRBASIC" command is set to PWR2. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AMRMAXSTEP1 AMR MAX Down Adj. Value Qual. Zone 1 BSC6900 SET GCELLPWR2(Optional) Maximum step by which the power can be decreased when the received signal quality belongs to quality zone 1. Huawei power control algorithm generation II classifies the received signal quality into three quality zones. The maximum step by which the power can be decreased according to signal level varies according to the quality zones. GBFD-115503AMR Power Control Interval Type 0~30 0~30 dB None 0 Cell This parameter is valid when "PWRCTRLSW" in the "SET GCELLPWRBASIC" command is set to PWR2. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AMRMAXSTEP2 AMR MAX Down Adj. Value Qual. Zone 2 BSC6900 SET GCELLPWR2(Optional) Maximum step by which the power can be decreased when the received signal quality belongs to quality zone 2. Huawei power control algorithm generation II classifies the received signal quality into three quality zones. The maximum step by which the power can be decreased according to signal level varies according to the quality zones. GBFD-115503AMR Power Control Interval Type 0~30 0~30 dB None 0 Cell This parameter is valid when "PWRCTRLSW" in the "SET GCELLPWRBASIC" command is set to PWR2. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AMRMAXVALADJRX AMR MAX Up Adj. PC Value by RX_LEV BSC6900 SET GCELLPWR2(Optional) Maximum step by which the power can be increased according to received signal level GBFD-115503AMR Power Control Interval Type 0~32 0~32 dB None 8 Cell This parameter is valid when "PWRCTRLSW" in the "SET GCELLPWRBASIC" command is set to PWR2. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AMRMRCOMPREG AMR MR. Compensation Allowed BSC6900 SET GCELLPWR2(Optional) Whether to enable the compensation of AMR measurement reports in Huawei power control algorithm generation IIIf this parameter is set to YES, Huawei power control algorithm generation II puts a currently received measurement report into the measurement report compensation queue. Then, the algorithm records the change in the transmit power based on the MS/BTS power in the measurement report. According to the power change, the algorithm compensates the received signal level in a history measurement report after measurement report interpolation.Before making a power control decision, the BSC samples and weights the received signal level and quality in several history measurement reports. The MS/BTS transmit power may vary over these measurement reports. To ensure the accuracy of the received signal level and quality to be weighted, the power control algorithm needs to compensate the received signal level and quality in the history measurement reports where the transmit power differs from the current transmit p GBFD-115503AMR Power Control Enumeration Type NO(No), YES(Yes)NO, YES None None YES Cell This parameter is valid when "PWRCTRLSW" in the "SET GCELLPWRBASIC" command is set to PWR2. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AMRPCADJPERIOD AMR PC Interval BSC6900 SET GCELLPWR2(Optional) Minimum interval between two consecutive AMR power control commands GBFD-115503AMR Power Control Interval Type 1~15 1~15, step:480 ms None 3 Cell This parameter is valid when "PWRCTRLSW" in the "SET GCELLPWRBASIC" command is set to PWR2. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AMRQUALSTEP AMR MAX Down Adj. PC Value by Qual. BSC6900 SET GCELLPWR2(Optional) Maximum step by which the power can be decreased according to received signal quality GBFD-115503AMR Power Control Interval Type 0~4 0~4 dB None 4 Cell This parameter is valid when "PWRCTRLSW" in the "SET GCELLPWRBASIC" command is set to PWR2. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AMRSADLUPGRADE AMR SACCH Downlink Power Upgrade BSC6900 SET GCELLPWRBASIC(Optional) Number of levels by which the BTS increases the power of an SACCH frame. This parameter is used for SACCH power control. When sending an SACCH frame, the BTS increases the power of the SACCH frame by this specified number of levels. GBFD-110703Enhanced Power Control Algorithm Interval Type 0~15 0~15 None None 0 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AMRTCHHPRIORALLOW AMR TCH/H Prior Allowed BSC6900 SET GCELLCHMGAD(Optional) Whether to enable the BSC to assign AMR half rate channels preferentially according to the channel types allowed by the MSC and the current TCH seizure ratio of the cell GBFD-115502AMR HR Enumeration Type OFF(Off), ON(On) OFF, ON None None ON Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AMRTCHHPRIORLOAD AMR TCH/H Prior Cell Load Threshold BSC6900 SET GCELLCHMGAD(Optional) Load threshold for assigning half rate channels preferentially. If the current TCH seizure ratio of the cell is greater than this threshold, amr half rate channels are assigned preferentially. GBFD-115502AMR HR Interval Type 0~99 0~99 per cent None 55 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AMRUADTHAW AMR Uplink Adaptive Threshold Allowed BSC6900 SET GCELLCCAMR(Optional) Whether to enable the adaptive adjustment function of AMR uplink threshold. After this function is enabled, the BTS estimates the long-term voice quality (indicated by the long-term FER(frame erase rate)) and compares the estimated result with the specified target voice quality. If the estimated result does not conform to the target voice quality, it indicates that the current AMR handover threshold may not be the best for the current radio conditions. In this case, the BSC uses the relevant algorithm to adjust the adaptive threshold according to the relation between the estimated voice quality and the target voice quality. GBFD-115506AMR Coding Rate Threshold Adaptive Adjustment Enumeration Type NO(No), YES(Yes)NO, YES None None NO Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AMRULLEVFTLEN AMR Filter Length for UL RX_LEV BSC6900 SET GCELLPWR2(Optional) Number of measurement reports sampled for averaging uplink AMR signal strength. A single measurement report may not reflect the actual network situations accurately. Therefore, the BSC needs to average the measured values in several successive measurement reports to reflect the radio environment. GBFD-115503AMR Power Control Interval Type 1~20 1~20, step:480 for TCH and 470 for SDCCH ms None 5 Cell This parameter is valid when "PWRCTRLSW" in the "SET GCELLPWRBASIC" command is set to PWR2. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AMRULPREDLEND AMR UL MR. Number Predicted BSC6900 SET GCELLPWR2(Optional) Number of uplink AMR measurement reports that the BSC predicts. The BSC takes a while to confirm the power control effect of a power control command. Thus, the BSC makes a power control decision based on a measurement report that lags behind the changes in the receive level and quality instead of reflecting the real-time radio environment. As a result, the power control is late.To prevent late power control to a certain degree, the power control algorithm involves a measurement report prediction filter. The BSC can sample several downlink measurement reports in a short time and then weight them to predict future N measurement reports.This parameter specifies the number N. GBFD-115503AMR Power Control Interval Type 0~3 0~3 None None 0 Cell This parameter is valid when "PWRCTRLSW" in the "SET GCELLPWRBASIC" command is set to PWR2 and "DNPCEN" in the "SET GCELLBASICPARA" command is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AMRULQHTHRED AMR UL Qual. Upper Threshold BSC6900 SET GCELLPWR2(Optional) Quality level threshold for decreasing the power of an uplink AMR call. If the MS transmits AMR signals at a quality level less than "AMR ULQual. Upper Threshold", the BTS decreases the power of the MS. If (uplink receive level - "AMR MAX Down Adj. PC Value by Qual.") < "AMR UL RX_LEV Lower Threshold", however, the BTS does not adjust the transmit power. GBFD-115503AMR Power Control Interval Type 0~7 0~7 None None 0 Cell This parameter is valid only when "PWRCTRLSW" in "SET GCELLPWRBASIC" is set to PWR2. The following condition must be met: "AMRULQLOWTHRED" >= "AMRULQHTHRED". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AMRULQLOWTHRED AMR UL Qual. Lower Threshold BSC6900 SET GCELLPWR2(Optional) Quality level threshold for increasing the power of an uplink AMR call. If the MS transmits AMR signals at a quality level greater than "AMR UL Qual. Lower Threshold", the BTS increases the power of the MS. If (uplink receive level + "AMR MAX Up Adj. PC Value by Qual.") > "AMR UL RX_LEV Upper Threshold", however, the BTS does not adjust the transmit power. GBFD-115503AMR Power Control Interval Type 0~7 0~7 None None 3 Cell This parameter is valid only when "PWRCTRLSW" in "SET GCELLPWRBASIC" is set to PWR2. The following condition must be met: "AMRULQLOWTHRED" >= "AMRULQHTHRED". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AMRULQUAFTLEN AMR Filter Length for UL Qual BSC6900 SET GCELLPWR2(Optional) Number of measurement reports sampled for averaging uplink AMR signal quality. A single measurement report may not reflect the actual network situations accurately. Therefore, the BSC needs to average the measured values in several successive measurement reports to reflect the radio environment. GBFD-115503AMR Power Control Interval Type 1~20 1~20, step:480 for TCH and 470 for SDCCH ms None 5 Cell This parameter is valid when "PWRCTRLSW" in the "SET GCELLPWRBASIC" command is set to PWR2. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AMRULQUALBADTRIG AMR UL Qual. Bad Trig Threshold BSC6900 SET GCELLPWR2(Optional) During uplink power control, if the uplink receive quality level is equal to or greater than this threshold, "AMR UL RX_LEV Upper Threshold" is increased by "AMR UL Qual. Bad UpLEVDiff" to further increase the expected uplink power level. GBFD-115503AMR Power Control Interval Type 0~7 0~7 None None 3 Cell This parameter is valid when "PWRCTRLSW" in the "SET GCELLPWRBASIC" command is set to PWR2. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AMRULQUALBADUPLEV AMR UL Qual. Bad UpLEVDiff BSC6900 SET GCELLPWR2(Optional) During uplink power control, if the uplink receive quality level is equal to or greater than "AMR UL Qual. Bad Trig Threshold", "AMR UL RX_LEV Upper Threshold" is increased by "AMR UL Qual. Bad UpLEVDiff" to further increase the expected uplink power level. GBFD-115503AMR Power Control Interval Type 0~63 0~63 dB None 6 Cell This parameter is valid when "PWRCTRLSW" in the "SET GCELLPWRBASIC" command is set to PWR2. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AMRULSSHTHRED AMR UL RX_LEV Upper Threshold BSC6900 SET GCELLPWR2(Optional) Upper threshold for uplink AMR signal strengthIf the uplink received AMR signal level is greater than this threshold, a power decrease is computed. Then, the power is decreased by the least of the power decrease, maximum power adjustment step allowed by the quality zone to which the received signal quality belongs, and "AMR MAX Down Adj. PC Value by Qual.".Power decrease = uplink received signal level - ("AMR UL RX_LEV Upper Threshold" + "AMR UL RX_LEV Lower Threshold")/2The maximum power adjustment step allowed by the quality zone is chosen from "AMR MAX Down Adj. Value Qual. Zone 0", "AMR MAX Down Adj. Value Qual. Zone 1", and "AMR MAX Down Adj. Value Qual. Zone 2" according to the quality zone. GBFD-115503AMR Power Control Interval Type 0~63 0~63 dB None 30 Cell This parameter is valid only when "PWRCTRLSW" in "SET GCELLPWRBASIC" is set to PWR2. The following condition must be met: "AMRULSSHTHRED" >= "AMRULSSLTHRED". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AMRULSSLTHRED AMR UL RX_LEV Lower Threshold BSC6900 SET GCELLPWR2(Optional) Lower threshold for uplink AMR signal strength.If the uplink received AMR signal level is less than this threshold, a power increase is computed. Then, the power is increased by the least of the power increase, "AMR MAX Up Adj. PC Value by RX_LEV", and "AMR MAX Up Adj. PC Value by Qual.".Power increase = ("AMR UL RX_LEV Upper Threshold" + "AMR UL RX_LEV Lower Threshold")/2 - uplink received signal level. GBFD-115503AMR Power Control Interval Type 0~63 0~63 dB None 18 Cell This parameter is valid only when "PWRCTRLSW" in "SET GCELLPWRBASIC" is set to PWR2. The following condition must be met: "AMRULSSHTHRED" >= "AMRULSSLTHRED". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AN19 MAX Retrans Reset Circle Msg on A-I BSC6900 SET OTHSOFTPARA(Optional) Maximum number of retransmissions of the A-interface circuit reset message. When an A-interface circuit of the BSC is reset, the BSC sends the reset message to the MSC and starts a timer. If the BSC fails to receive the A-interface circuit reset response message from the MSC before the timer expires, the BSC retransmits the A-interface circuit reset message. This parameter specifies the maximum number of retransmissions of the A-interface circuit reset message. GBFD-111803A Interface Circuit Management Interval Type 0~65535 0~65535 None None 2 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AN4 MAX Reset Mesg Retransmission on A-I BSC6900 SET AITFOTHPARA(Optional) Maximum number of times of resending a reset message at the A interface. When the BSC is reset, the BSC sends a reset message to the MSC and starts a timer. If the timer expires when the BSC waits for a response message, the BSC resends the reset message and restarts a timer. If the timer expires again and the times of resending the reset message are less than the value of this parameter, the BSC continues resending the reset message. GBFD-111803A Interface Circuit Management Interval Type 0~65535 0~65535 None None 2 MSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ANC_Max_Gain ANC Max Gain BSC6900 SET TCPARA(Optional) Maximum gain to the signals from the remote end. If the parameter is set to a small value, the target SNR may be restrained when the signal arrives at the local end. GBFD-115603Automatic Noise Restraint (ANR) Interval Type 3~30 3~30 dB None 6 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ANC_Switch ANC Switch BSC6900 SET TCPARA(Optional) Whether to enable the adaptive noise cancel (ANC) function GBFD-115603Automatic Noise Restraint (ANR) Enumeration Type CLOSE(Close), OPEN(Open) CLOSE, OPEN None None CLOSE Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ANC_Target_SNR ANC Target SNR BSC6900 SET TCPARA(Optional) The system adjusts the remote input so that the ratio of the remote signal to the local noise is above the value of this parameter. GBFD-115603Automatic Noise Restraint (ANR) Interval Type 10~30 10~30 dB None 12 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ANGLE RET Antenna Tilt Angle BSC6900 SET BTSANTANGLE(Mandatory) Tilt angle of the RET antenna MRFD-210602Remote Electrical Tilt String Type None 1~5 characters None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ANI Adjacent Node ID BSC6900 ADD ADJNODE(Mandatory)ADD IPPATH(Mandatory)ADD ADJMAP(Mandatory) Adjacent node ID None None Interval Type 0~4599 0~4599 None None None Adjacent node None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
ANI Adjacent node ID BSC6900 ADD IPMUX(Mandatory)ADD IPPATHBIND(Mandatory) Adjacent node identifier of this IP path None None Interval Type 0~4599 0~4599 None None None IP path None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The adjacent node ID must be configured.
ANM Alarm Name BSC6900 SET ENVALMPARA(Optional) New name of the alarm MRFD-210304Faulty Management String Type None 1~100 characters None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ANR_Mode ANR Mode BSC6900 SET TCPARA(Optional) ANR mode GBFD-115603Automatic Noise Restraint (ANR) Enumeration Type MODE0(Mode 0), MODE1(Mode 1), MODE2(Mode 2) MODE0, MODE1, MODE2 None None MODE0 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ANR_Noise_Reduction_Level ANR Noise Reduction Level BSC6900 SET TCPARA(Optional) This parameter determines the noise depression degree. A great absolute value of this parameter corresponds to a strong depression. GBFD-115603Automatic Noise Restraint (ANR) Interval Type -32~0 -32~0 dB None -13 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ANR_Noise_Target_Level ANR Noise Target Level BSC6900 SET TCPARA(Optional) ANR target noise level GBFD-115603Automatic Noise Restraint (ANR) Interval Type -64~0 -64~0 dB None -48 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ANR_Switch ANR Switch BSC6900 SET TCPARA(Optional) Whether to enable the adaptive noise restrain (ANR) function GBFD-115603Automatic Noise Restraint (ANR) Enumeration Type CLOSE(Close), OPEN(Open) CLOSE, OPEN None None CLOSE Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
5/5/2014
Confidential Information of Huawei.
No Spreading without Permission
Page3of42
226347869.xls.ms_office Security Level:
ANTAANGLE Antenna Azimuth Angle BSC6900 SET GCELLLCS(Optional) Size of the azimuth angle of the cell antenna GBFD-115402BSS-Based LCS (Cell ID + TA) Interval Type 0~360 0~360 degreeNone None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ANTENNALONG GPS Antenna Delay BSC6900 SET BTSDGPSBP(Optional)SET BTSUSCUBP(Optional) Length of the feeder cable. The GPS satellite card is connected to the antenna through feeder cables. The transmission delay on the feeder cable can be calculated on the basis of the length of the feeder cable, thus increasing the timing accuracy of the satellite card. GBFD-510401BTS GPS Synchronization Interval Type 0~1000 0~1000 m None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ANTENNAPOWERSWITCH Antenna Power Supply Switch BSC6900 SET BTSDGPSBP(Optional)SET BTSUSCUBP(Optional) Power supply switch of the GPS antenna feeder GBFD-510401BTS GPS Synchronization Enumeration Type SENDPOWER(Send Power), NOPOWER(No Power) SENDPOWER, NOPOWER None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ANTIERRFLAG E1T1 anti-error switch BSC6900 ADD MPGRP(Optional) E1T1 anti-error switch. GBFD-118611GBFD-118622 Abis IP over E1/T1A IP over E1/T1 Enumeration Type OFF(OFF), ON(ON) OFF, ON None OFF OFF Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AntiTheftAllow Burglar Alarm Auto Clear Permit BSC6900 SET BTSTHEFTALM(Optional) Whether to enable the BTS to clear the burglar alarm automatically GBFD-111202O&M of BTS Enumeration Type NO(No), YES(Yes)NO, YES None None NO BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ANTNO Antenna No. BSC6900 LOD RETANTCFG(Mandatory)SET BTSANTANGLE(Mandatory)SET RETANTENB(Mandatory) Number of the antenna MRFD-210602Remote Electrical Tilt Interval Type 0~35 0~35 None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ANTPASSNO Antenna Pass No BSC6900 ADD TRXBIND2PHYBRD(Mandatory) Number of the antenna feeder channel mapped to the RXU GBFD-111202O&M of BTS Enumeration Type A(A), B(B) A, B None None None TRX None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
ANTPASSNO Sub-Location Group Antenna Pass No. BSC6900 ADD BTSBINDLOCGRP(Optional) Antenna pass No. of the RXU of a sub-location group. The parameter is configured only when the MRRU or GRRU is used in the sub-location group. GBFD-510104Multi-site Cell Enumeration Type A(A), B(B) A, B None None None TRX None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AORB Down TRX1 A OR B BSC6900 ADD BTSANTFEEDERBRD(Mandatory)SET BTSANTFEEDERCONNECT(Optional) Antenna pass number of the downlink tributary GBFD-111202O&M of BTS Enumeration Type A(A), B(B), NULL(NULL) A, B, NULL None None None BTS The setting of this parameter depends on "Board Type". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
APN A interface port No. BSC6900 ADD MTP3LNK(Mandatory) A interface port No.. None None Interval Type 0~335 0~335 None None None MTP3 linkNone Read & Write Not involved Not involved Not involved The parameter cannot be modified.
APP Application type BSC6900 ADD SCTPLNK(Mandatory) Upper layer application type of the SCTP link. The upper layer application type of the Iub interface is NBAP. The upper layer application type of the Iur, IuPS, and IuCS interface is M3UA. In the BSC disaster tolerance, the application type is BBAP in the case of the communication between the primary and secondary BSC. None None Enumeration Type NBAP(NBAP), M3UA(M3UA), BBAP(BBAP) NBAP, M3UA, BBAP None None None SCTP linkNone Read & Write Not involved Not involved Not involved The parameter cannot be modified.
APPTYPE Application Type BSC6900 ADD SEMILINK(Mandatory) Application type of the semi-permanent link. GBFD-114701Semi-Permanent Connection Enumeration Type MTP2, OTHER, TCSTM1 MTP2, OTHER, TCSTM1 None None None BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AqmM AQM N Update Interval BSC6900 SET BSCPSSOFTPARA(Optional) Update frequency of the value N (packet drop interval), indicating that the packet drop interval is updated after N packets are transmitted. GBFD-119904PS Active Queue Management Interval Type 1~65535 1~65535 packetNone 20 BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter is valid only when "AqmSwitch" is set to OPEN.
AqmMaxTh AQM Maximum Threshold BSC6900 SET BSCPSSOFTPARA(Optional) Upper length threshold of the TBF buffer queue. If the length of the TBF buffer queue exceeds this threshold, whether the packets are discarded is determined according to the packet discarding policy. GBFD-119904PS Active Queue Management Interval Type 1~65535 1~65535, step:1024 bit None 1024 BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter is valid only when "AqmSwitch" is set to OPEN.
AqmMinTh AQM Congestion Threshold BSC6900 SET BSCPSSOFTPARA(Optional) Congestion threshold of the TBF buffer queue. If the congestion level in the TBF buffer queue exceeds this threshold, whether the packets are discarded actively is determined according to the packet discarding policy. GBFD-119904PS Active Queue Management Interval Type 1~65535 1~65535, step:1024 bit None 256 BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter is valid only when "AqmSwitch" is set to OPEN.
AqmNinit AQM Packet Discard Initial Interval BSC6900 SET BSCPSSOFTPARA(Optional) Initial value of the interval (indicated by N) at which the packets in the TBF buffer queue are discarded. The value N indicates the frequency of discarding the packets in the TBF buffer queue. The greater the value N, the lower the frequency of discarding packets, and the smaller the number of discarded packets within a certain period. The smaller the value N, the greater the number of discarded packets. GBFD-119904PS Active Queue Management Interval Type 1~65535 1~65535 packetNone 20 BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter is valid only when "AqmSwitch" is set to OPEN.
AqmNLowerBound AQM Packet Discard Interval Lower Threshold BSC6900 SET BSCPSSOFTPARA(Optional) Lower threshold of the interval for discarding the packets in the TBF buffer queue, that is, the minimum value of N (packet drop interval). GBFD-119904PS Active Queue Management Interval Type 1~65535 1~65535 packetNone 10 BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter is valid only when "AqmSwitch" is set to OPEN.
AqmNUpBound AQM Packet Discard Interval Upper Threshold BSC6900 SET BSCPSSOFTPARA(Optional) Upper threshold of the interval for discarding the packets in the TBF buffer queue, that is, the maximum value of N (packet drop interval). GBFD-119904PS Active Queue Management Interval Type 1~65535 1~65535 packetNone 20 BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter is valid only when "AqmSwitch" is set to OPEN.
AqmSwitch AQM Switch BSC6900 SET BSCPSSOFTPARA(Optional) AQM switch. GBFD-119904PS Active Queue Management Enumeration Type CLOSE(Close), OPEN(Open) CLOSE, OPEN None None CLOSE BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AqmTarTh AQM Target Threshold BSC6900 SET BSCPSSOFTPARA(Optional) Target threshold of the TBF buffer queue. GBFD-119904PS Active Queue Management Interval Type 1~65535 1~65535, step:1024 bit None 384 BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter is valid only when "AqmSwitch" is set to OPEN.
AreaCode Area Code BSC6900 SET BSCBASIC(Optional) Local area code, for example, 021 for Shanghai MRFD-210301Configuration Management Interval Type 0~65535 0~65535 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AREAFLAG Area flag BSC6900 CMP BRDAREA(Optional)LOD PATCH(Optional) Area flag MRFD-210401BSC/RNC Software Management Enumeration Type PRIMARY(Primary), STANDBY(Standby), ALL PRIMARY, STANDBY, ALL None PRIMARY None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AREAFLAG Area flag BSC6900 SYN BRDAREA(Optional) Area flag MRFD-210401BSC/RNC Software Management Enumeration Type PRIMARY(Primary), STANDBY(Standby) PRIMARY, STANDBYNone PRIMARY PRIMARY None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AREDISTHD Abnormal Release Threshold BSC6900 SET GTRXRLALM(Optional) Threshold for reporting the recovery alarm for the abnormal release alarm. If the percentage of the abnormal channel releases is equal to or less than this threshold, the recovery alarm for the abnormal release alarm is reported. That is, the abnormal release alarm is cleared. GBFD-111004Radio Dedicated Channel Management Interval Type 0~80 0~80 per cent None 50 TRX This parameter is valid only when "WLNKALMFLAG" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ARELBASE Abnormal Release Statistic Base BSC6900 SET GTRXRLALM(Optional) Release statistics base for subchannels. This parameter indicates the number of times that a subchannel is activated. In a timeslot, the release statistics base, B, multiplied by the number of channels, N, is the channel release sum, S.If the percentage of the abnormal channel releases in the latest S channel releases exceeds the Abnormal Warn Threshold, the abnormal release alarm is reported.If the percentage of the abnormal channel releases in the latest S channel releases is equal to or less than the Abnormal Release Threshold, the recovery alarm for the abnormal release alarm is reported. That is, the abnormal release alarm is cleared. GBFD-111004Radio Dedicated Channel Management Interval Type 5~126 5~126 None None 100 TRX This parameter is valid only when "WLNKALMFLAG" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ARELWTHD Abnormal Warn Threshold BSC6900 SET GTRXRLALM(Optional) Threshold for reporting the abnormal release alarm. In a timeslot, the release statistics base, B, multiplied by the number of channels, N, is the channel release sum, S. If the percentage of the abnormal channel releases in the latest S channel releases exceeds this threshold, the abnormal release alarm is reported. GBFD-111004Radio Dedicated Channel Management Interval Type 5~100 5~100 per cent None 100 TRX This parameter is valid only when "WLNKALMFLAG" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ARPRETRY ARP packet resend times BSC6900 STR IPCHK(Optional) Retransmission times upon ARP timeout. When the ARP request times exceeds the retransmission time without a response, the ARP/BFD detection failure alarm is reported. This may trigger the port or board switchover. GBFD-118609IP Fault Detection Based on BFD Interval Type 3~10 3~10 None 3 3 Ethernet port None Read & Write Y Ethernet port Interrupt the service until the correct gateway is set or the port swapping or the changing of IP route is finished. To modify this parameter, run "STP GATEWAYCHK" first and then "STR GATEWAYCHK".
ARPTIMEOUT ARP packet time-out[100ms] BSC6900 STR IPCHK(Optional) ARP packet timeout time GBFD-118609IP Fault Detection Based on BFD Interval Type 3~10 3~10 ms 3 3 Ethernet port None Read & Write N (No impact on the UE in idle mode) Not involved Not involved To modify this parameter, run "STP GATEWAYCHK" first and then "STR GATEWAYCHK".
ASN A interface slot No. BSC6900 ADD MTP3LNK(Mandatory) A interface slot No.. None None Interval Type 0~27 0~27 None None None MTP3 linkNone Read & Write Not involved Not involved Not involved The parameter cannot be modified.
ASN A interface slot No. BSC6900 ADD ATERSL(Optional)ADD ATERCONSL(Optional) A interface slot No.. GBFD-111804A Interface Protocol Process Interval Type 0~27 0~27 None None None ATERCONSL None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ASRN A interface subrack No. BSC6900 ADD MTP3LNK(Mandatory) A interface subrack No.. None None Interval Type 0~11 0~11 None None None MTP3 linkNone Read & Write Not involved Not involved Not involved The parameter cannot be modified.
ass Event Type BSC6900 EXP ALMLOG(Optional)STAALMLOG(Optional) Network management type of the alarm. By default, all network management types are selected. MRFD-210304Faulty Management Bit Field Type power, env, sig, trunk, hardware, software, run, comm, service, handle power, env, sig, trunk, hardware, software, run, comm, service, handle None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ASS Event Type BSC6900 SET ENVALMPARA(Optional) Network management type of the alarm. By default, all network management types are selected. MRFD-210304Faulty Management Enumeration Type power(Power System), env(Environment System), sig(Signaling System), trunk(Trunk System), hardware(Hardware System), software(Software System), run(Running System), comm(Communication System), service(QoS), handle(Processing Error) power, env, sig, trunk, hardware, software, run, comm, service, handle None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ASSLOADJUDGEEN Assignment Cell Load Judge Enable BSC6900 SET GCELLCCBASIC(Optional) When this parameter is set to ENABLE, if the cell supports direct retry and the current cell load is equal to or larger than the value of "Cell direct retry forbidden threshold" in "SET GCELLOTHEXT" during the assignment, the BSC continues with the direct retry procedure. GBFD-110607Direct Retry Enumeration Type DISABLE(Disable), ENABLE(Enable) DISABLE, ENABLE None None DISABLE Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ASSOLRXLEVOFFSET Assign to Overlayer RxLev Offset BSC6900 SET GCELLCHMGAD(Optional) Offset relative to the level threshold for determining whether to assign a channel in the overlaid subcell GBFD-113201Concentric Cell Interval Type 0~61 0~61 dB None 35 Cell In an enhanced concentric cell, if "LOWRXLEVOLFORBIDSWITCH" is set to ON, this parameter and "OTOURECEIVETH" determine whether the current uplink receive level meets the condition for assigning channels of the overlaid subcell during the assignment of the underlaid subcell channels and overlaid subcell channels.In a normal concentric cell, if "LOWRXLEVOLFORBIDSWITCH" is set to ON, this parameter, together with "RECLEVTHRES" and "RECLEVHYST", determines whether the current uplink receive level meets the condition for assigning channels of the overlaid subcell during the assignment of the underlaid subcell channels and overlaid subcell channels. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ASSORXUCN Associated RXU Board CN BSC6900 SET BTSAPMUBP(Optional)SET BTSDEMUBP(Optional)SET BTSDHEUBP(Optional) Number of the cabinet where the associated RXU board is installed. This parameter is valid for DRRU, MRRU, GRRU, or BTS3900E board in the remote monitoring subrack of the DBS3036, DBS3900 GSM, or BTS3900E GSM. The associated RXU board cannot be associated with other boards such as DEMU, APMU, or DTCU. GBFD-111202O&M of BTS Interval Type 0~62,255 0~62, 255 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ASSORXUCN Associated RXU Board CN BSC6900 SET BTSRXUBP(Mandatory) Number of the cabinet where the associated RXU board is installed. This parameter is valid for DRRU, MRRU, GRRU, or BTS3900E board in the remote monitoring subrack of the DBS3036, DBS3900 GSM, or BTS3900E GSM. The associated RXU board cannot be associated with other boards such as DEMU, APMU, or DTCU. GBFD-111202O&M of BTS Interval Type 0~62 0~62 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ASSORXUSN Associated RXU Board SN BSC6900 SET BTSAPMUBP(Optional)SET BTSDEMUBP(Optional)SET BTSDHEUBP(Optional) Number of the slot where the associated RXU board is installed. GBFD-111202O&M of BTS Interval Type 0~23,255 0~23, 255 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ASSORXUSN Associated RXU Board SN BSC6900 SET BTSRXUBP(Mandatory) Number of the slot where the associated RXU board is installed. GBFD-111202O&M of BTS Interval Type 0~23 0~23 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ASSORXUSRN Associated RXU Board SRN BSC6900 SET BTSAPMUBP(Optional)SET BTSDEMUBP(Optional)SET BTSDHEUBP(Optional) Number of the subrack where the associated RXU board is installed. GBFD-111202O&M of BTS Interval Type 0~255 0~255 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ASSORXUSRN Associated RXU Board SRN BSC6900 SET BTSRXUBP(Mandatory) Number of the subrack where the associated RXU board is installed. GBFD-111202O&M of BTS Interval Type 0~254 0~254 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ASSThres Absolute Signal Strength Threshold BSC6900 SET OTHSOFTPARA(Optional) Absolute level threshold for automatic optimization of neighbor cells and frequencies. The measurement results in measurement reports are screened and counted according to this threshold. If the signal strength of a neighbor cell in a measurement report is greater than this threshold, the relevant traffic statistics counter is incremented by one. GBFD-5109012G/3G Neighboring Cell Automatic Optimization Interval Type 0~63 0~63 dB None 30 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ASSTIMER T3107 BSC6900 SET GCELLTMR(Optional) After the BSC delivers an assignment command, the T3107 timer starts. If the BSC receives an assignment complete message within the scheduled time, the T3107 timer stops. If the timer expires, the BSC sends an assignment failure message. GBFD-110502Assignment and Immediate Assignment Interval Type 500~60000 500~60000 ms None 10000 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AT1 T1 BSC6900 SET BSCTMR(Optional) Timer for waiting for a single A-interface circuit blocking or unblocking answer.The BSC starts this T1 timer after sending a single A-interface circuit blocking or unblocking message. If the BSC does not receive a blocking or unblocking answer from the MSC before this timer expires for the first time, the BSC resends the single A-interface circuit blocking or unblocking message to the MSC. If the timer expires for the second time, the BSC reports an alarm for BSC circuit blocking or unblocking failure. GBFD-111203O&M of BSC Interval Type 1~300 1~300 s None 30 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AT13 T13 -s BSC6900 SET BSCAITFTMR(Optional) MSC reset protection timer, that is, interval between the time when the BSC receives an MSC reset message and the time when the BSC answer to the MSC. GBFD-111803A Interface Circuit Management Interval Type 1~300 1~300 s None 150 MSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AT17 T17 -s BSC6900 SET BSCAITFTMR(Optional) T17 timer. When receiving an MSC overload message or a single point congestion message for the first time, the BSC increases the level of the A interface flow control and starts the T17 and T18 timers at the same time. Timers T17 and T18 are set for adjusting the flow control level over the A interface. GBFD-111705GSM Flow Control Interval Type 1~300 1~300 s None 30 BSC6900This parameter is used with "T18 -s" in flow control over the A interface. The value of this parameter should be smaller than "T18 -s". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AT18 T18 -s BSC6900 SET BSCAITFTMR(Optional) T18 timer. When receiving an MSC overload message or a single point congestion message for the first time, the BSC increases the level of the A interface flow control and starts the T17 and T18 timers at the same time. Timers T17 and T18 are set for adjusting the flow control level over the A interface. GBFD-111705GSM Flow Control Interval Type 1~300 1~300 s None 60 MSC This parameter is used with "T17 -s" in flow control over the A interface. The value of this parameter should be greater than "T17 -s". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AT19 T19 BSC6900 SET BSCTMR(Optional) Timer for waiting for an A-interface circuit reset answer.The BSC starts this timer after sending an A-interface circuit reset message. When this timer expires for the first time, the BSC resends the circuit reset message to the MSC. If this timer expires for the second time, the BSC reports an alarm for BSC circuit resetting failure. GBFD-111203O&M of BSC Interval Type 1~300 1~300 s None 30 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AT20 T20 BSC6900 SET BSCTMR(Optional) Timer for waiting for an A-interface circuit group blocking or unblocking answer. After sending a CIC group blocking/unblocking message over the A interface, the BSC starts the timer T20. If the BSC fails to receive a response from the MSC before the first expiry of T20, the BSC resends the CIC group blocking/unblocking message. If no response is received before the second expiry of T20, the system reports the BSC Unable to Block Group Circuits or BSC Unable to Unblock Group Circuits alarm. GBFD-111203O&M of BSC Interval Type 1~300 1~300 s None 30 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AT4 T4 -s BSC6900 SET BSCAITFTMR(Optional) Timer for waiting for an A-interface reset answer GBFD-111803A Interface Circuit Management Interval Type 1~300 1~300 s None 20 MSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ATCBHOEN Concentric Circles ATCB HO Allowed BSC6900 SET GCELLHOBASIC(Optional) Whether to enable the ATCB handover algorithm for the concentric cell. According to the neighbor cell signal, the ATCB handover algorithm determines the coverage of the overlaid subcell and balances the load between the overlaid subcell, underlaid subcell, and neighbor cell. Therefore, the algorithm helps to decrease the interference, to improve the conversation quality, and to achieve aggressive frequency reuse in the overlaid subcell. GBFD-113201Concentric Cell Enumeration Type NO(Close), YES(Open) NO, YES None None NO Cell This parameter is valid only when "IUOTP" is set to Concentric_cell. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ATCBHYST Distance Hysterisis Between Boundaries BSC6900 SET GCELLHOEDBPARA(Optional) Hysteresis in the distance between the boundary of the overlaid subcell and the boundary of the underlaid subcell. This parameter helps to adjust "Distance Between Boudaries of Subcells" and thus to prevent ping-pong handover between the overlaid and underlaid subcells. Assume that the signal strength of the serving cell is SS(s) and that the signal strength of the neighbor cell is SS(n). If SS(s) - SS(n) < "Distance Between Boudaries of Subcells" - "Distance Hysterisis Between Boudaries", the MS is handed over from the overlaid subcell to the underlaid subcell. GBFD-114402Enhanced Dual-Band Network Interval Type 0~63 0~63 dB None 2 Cell This parameter is valid only when "ATCBHoSwitch" is set to OPEN, "IUOTP" is set to EDB_cell, or "TIGHTBCCHSWITCH" is set to ON. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ATCBTHRED Distance Between Boundaries of Subcells BSC6900 SET GCELLHOEDBPARA(Optional) Distance between the boundary of the overlaid subcell and the boundary of the underlaid subcell. This parameter specifies the difference between the coverage of the overlaid subcell and the coverage of the underlaid subcell in the concentric cell or dual-frequency network scenario. The boundaries of the overlaid and underlaid subcells are determined according to the relative value between the signal strength of the serving cell and the signal strength of the neighbor cell. Assume that the signal strength of the serving cell is SS(s) and that the signal strength of the neighbor cell is SS(n). If SS(s) = SS(n), the MS is on the boundary of the underlaid subcell. If SS(s) - SS(n) > "Distance Between Boudaries of Subcells", the MS is in the coverage of the overlaid subcell.In the tight BCCH handover algorithm, this parameter specifies the difference between the coverage of the TRX that carries the BCCH and the coverage of the TRX that does not carry the BCCH. The relevant computation is the same as the preceding GBFD-114402Enhanced Dual-Band Network Interval Type 0~63 0~63 dB None 10 Cell This parameter is valid only when "ATCBHoSwitch" is set to OPEN, "IUOTP" is set to EDB_cell, or "TIGHTBCCHSWITCH" is set to ON. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
Ater8KSw Switch of 8K On Ater BSC6900 SET OTHSOFTPARA(Optional) Whether to enable the BSC to use a 8 kbit/s timeslot to transmit 8 kbit/s data at the Ater interface GBFD-116901Flex Ater Enumeration Type NO, YES NO, YES None None YES BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AterCongHRFlag HR Allocation Flag BSC6900 SET OTHSOFTPARA(Optional) Whether to enable the BSC to assign half rate channels preferentially when the Ater interface is congested GBFD-116901Flex Ater Enumeration Type Close, Open Close, Open None None Open BSC6900If the resource usage on the Ater interface exceeds the value of "AterCongstRatio" and this parameter is set to Open, the BSC preferentially selects TCHF when assigning traffic channels. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AterCongstRatio Congestion Ratio on Ater Resource BSC6900 SET OTHSOFTPARA(Optional) Threshold for considering the Ater interface congested. The BSC determines whether to assign full or half rate channels preferentially according to the congestion situations at the Ater interface. If the Ater resource usage exceeds this parameter, the Ater interface is considered congested. GBFD-116901Flex Ater Interval Type 80~100 80~100 per cent None 85 BSC6900This parameter is valid only when "AterCongHRFlag" is set to OPEN. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ATERIDX Ater connection path index BSC6900 ADD MTP3LNK(Mandatory)ADD ATERE1T1(Mandatory)ADD ATERCONPATH(Optional)ADD ATERSL(Mandatory)ADD ATERCONSL(Mandatory)ADD SEMILINK(Mandatory) Index of an Ater connection path. None None Interval Type 0~254 0~254 None None None MTP3 linkNone Read & Write Not involved Not involved Not involved The parameter cannot be modified.
AterJamThreshold2StartLs Ater Jam Rate for BSC Local Switch BSC6900 SET BSSLS(Optional) Threshold for enabling the BSC local switching. When the congestion rate at the Ater interface exceeds this threshold, the function is enabled. GBFD-117701BSC Local Switch Interval Type 0~100 0~100 per cent None 90 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ATERMASK Ater Mask BSC6900 ADD MTP3LNK(Mandatory)ADD ATERSL(Mandatory)ADD ATERCONSL(Mandatory) Ater interface timeslot mask. None None Bit Field Type TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10, TS11, TS12, TS13, TS14, TS15, TS16, TS17, TS18, TS19, TS20, TS21, TS22, TS23, TS24, TS25, TS26, TS27, TS28, TS29, TS30, TS31 TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10, TS11, TS12, TS13, TS14, TS15, TS16, TS17, TS18, TS19, TS20, TS21, TS22, TS23, TS24, TS25, TS26, TS27, TS28, TS29, TS30, TS31 None None None E1/T1 linkNone Read & Write Not involved Not involved Not involved The parameter cannot be modified.
ATEROMLFLAG Whether or not for OML BSC6900 ADD SEMILINK(Mandatory) Whether to configure the Ater OML link used for the TC subrack for the port. If it is actually configured and you specify that it is not configured, the TC subrack fails to start. If it is not configured and you specify that it is already configured, the crosstalk of the timeslot on the port occurs. GBFD-114701Semi-Permanent Connection Enumeration Type NO, YES NO, YES None None None BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ATEROMLINX Ater OML Index BSC6900 ADD ATEROML(Mandatory) Ater maintenance link index MRFD-210301Configuration Management Interval Type 0~1 0~1 None None None E1/T1 linkNone Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ATERPIDX Ater Connection Path Index BSC6900 ADD ATEROML(Mandatory) Ater connection path index MRFD-210301Configuration Management Interval Type 0~254 0~254 None None None E1/T1 linkNone Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ATERSLID Ater Signaling Channel ID BSC6900 ADD ATERSL(Optional)ADD ATERCONSL(Optional) To indentify an Ater signaling channel. GBFD-111203O&M of BSC Interval Type 0~2047 0~2047 None None None ATERCONSL None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
ATERTRANSMODE Ater Interface Transfer Mode BSC6900 SET BSCBASIC(Mandatory) Transport mode of the Ater interface. The Ater interface can be in TDM or in IP transport mode. GBFD-116902Ater Compression Transmission Enumeration Type TDM(TDM), IP(IP)TDM, IP None None None BSC6900None Read & Write Y BSC6900 Less than 10 minutes None
ATN Antenna Tributary No. BSC6900 STR BTSVSWRTST(Optional) Number of the RF port on the RF front-end board of the BTS. The number is unique in a board. GBFD-111202O&M of BTS Enumeration Type A(Tributary A), B(Tributary B), ALL(All Tributary) A, B, ALL None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ATSMASK A interface timeslot mask BSC6900 ADD MTP3LNK(Mandatory) A interface timeslot mask. None None Bit Field Type TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10, TS11, TS12, TS13, TS14, TS15, TS16, TS17, TS18, TS19, TS20, TS21, TS22, TS23, TS24, TS25, TS26, TS27, TS28, TS29, TS30, TS31 TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10, TS11, TS12, TS13, TS14, TS15, TS16, TS17, TS18, TS19, TS20, TS21, TS22, TS23, TS24, TS25, TS26, TS27, TS28, TS29, TS30, TS31 None None None MTP3 linkNone Read & Write Not involved Not involved Not involved The parameter cannot be modified.
ATT Attach-detach allowed BSC6900 SET GCELLIDLEBASIC(Optional) Attach-detach allowed (ATT). If this parameter is set to YES, when a MS is powered off, the network does not process any call connection for the MS as a called party. In this way, the network processing time and resources are saved. GBFD-110302IMSI Detach Enumeration Type NO(No), YES(Yes)NO, YES None None YES Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The ATT must be set to the same value for different cells in a same location area. If not, some MSs after power-on may not act as a called party until they have waited for the period specified by "T3212".
ATTENFACTOR1 Antenna Tributary 1 Factor BSC6900 SET BTSRXUBP(Optional) TMA attenuation factor of antenna tributary 1 [dB] GBFD-111202O&M of BTS Interval Type 0~15 0~15 dB None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ATTENFACTOR2 Antenna Tributary 2 Factor BSC6900 SET BTSRXUBP(Optional) TMA attenuation factor of antenna tributary 2 GBFD-111202O&M of BTS Interval Type 0~15 0~15 dB None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AUSTOP Loop time[min] BSC6900 SET E1T1LOP(Optional) It specifies the loopback duration. None None Interval Type 1~65535 1~65535 min None 60 None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AUSTOP Test time[min] BSC6900 STR E1T1TST(Optional) It specifies the test duration. None None Interval Type 1~60 1~60 min 1 1 E1/T1 port None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AUTHMODE Authentication Mode BSC6900 SET SSLAUTHMODE(Mandatory) SSL authentication mode of the peer certificate MRFD-210305Security Management Enumeration Type NONE(Verify None), PEER(Verify Peer Certificate) NONE, PEER None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AUTHMODE Validate mode BSC6900 ADD PPPLNK(Mandatory) Verification mode upon PPP or MP link negotiation GBFD-118611GBFD-118622 Abis IP over E1/T1A IP over E1/T1 Enumeration Type SERVER(SERVER), CLIENT(CLIENT) SERVER, CLIENT None None None PPP link None Read & Write Y PPP link Interrupt the service until negotiate successfully again. Negotiation can succeed only when the configuration is consistent on the local and peer ends.
AUTHMODE Validate mode BSC6900 ADD MPGRP(Mandatory) Verification mode upon PPP or MP link negotiation GBFD-118611GBFD-118622 Abis IP over E1/T1A IP over E1/T1 Enumeration Type SERVER(SERVER), CLIENT(CLIENT) SERVER, CLIENT None None None MP groupNone Read & Write Y BSC6900 Interrupt the service until negotiate successfully again. Negotiation can succeed only when the configuration is consistent on the local and peer ends.
AUTHMODE Validate mode BSC6900 ADD BTSPPPLNK(Mandatory)ADD BTSMPGRP(Mandatory) Validation mode of the PPP link negotiation or MLPPP link negotiation GBFD-118611Abis IP over E1/T1 Enumeration Type SERVER, CLIENT SERVER, CLIENT None None None BTS None Read & Write Y PPP link Less than 5 minutes Negotiation can succeed only when the configuration is consistent on the local and peer ends.
AUTHNAME Validate user name BSC6900 ADD PPPLNK(Mandatory) Username upon PPP or MP link negotiation GBFD-118611GBFD-118622 Abis IP over E1/T1A IP over E1/T1 String Type None 1~63 characters None None None PPP link None Read & Write Y BSC6900 Interrupt the service until negotiate successfully again. Negotiation can succeed only when the configuration is consistent on the local and peer ends.
AUTHNAME Validate user name BSC6900 ADD MPGRP(Mandatory) Username upon PPP or MP link negotiation GBFD-118611GBFD-118622 Abis IP over E1/T1A IP over E1/T1 String Type None 1~63 characters None None None MP groupNone Read & Write Y BSC6900 Interrupt the service until negotiate successfully again. Negotiation can succeed only when the configuration is consistent on the local and peer ends.
AUTHNAME Validate user name BSC6900 ADD BTSPPPLNK(Mandatory)ADD BTSMPGRP(Mandatory) Validation user name of the PPP link negotiation or MLPPP link negotiation GBFD-118611Abis IP over E1/T1 String Type None 1~64 characters None None None BTS This parameter is required only when "Validate protocol type" is set to "PAP_V" or "CHAP_V" with the "ADD PPPLNK" command. Read & Write Y PPP link Less than 5 minutes Negotiation can succeed only when the configuration is consistent on the local and peer ends.
AUTHPWD Validate password BSC6900 ADD PPPLNK(Mandatory) Password upon PPP or MP link negotiation GBFD-118611GBFD-118622 Abis IP over E1/T1A IP over E1/T1 String Type None 1~15 characters None None None PPP link None Read & Write Y PPP link Interrupt the service until negotiate successfully again. Negotiation can succeed only when the configuration is consistent on the local and peer ends.
AUTHPWD Validate password BSC6900 ADD MPGRP(Mandatory) Password upon PPP or MP link negotiation GBFD-118611GBFD-118622 Abis IP over E1/T1A IP over E1/T1 String Type None 1~15 characters None None None MP groupNone Read & Write Y BSC6900 Interrupt the service until negotiate successfully again. Negotiation can succeed only when the configuration is consistent on the local and peer ends.
AUTHPWD Validate password BSC6900 ADD BTSPPPLNK(Mandatory)ADD BTSMPGRP(Mandatory) Validation password of the PPP link negotiation or MLPPP link negotiation GBFD-118611Abis IP over E1/T1 String Type None 1~16 characters None None None BTS This parameter is required only when "Validate protocol type" is set to "PAP_V" or "CHAP_V" in the "ADD PPPLNK" command. Read & Write Y PPP link Less than 5 minutes Negotiation can succeed only when the configuration is consistent on the local and peer ends.
AUTHTYPE Validate protocol type BSC6900 ADD PPPLNK(Optional) Verification protocol type upon PPP or MP link negotiation GBFD-118611GBFD-118622 Abis IP over E1/T1A IP over E1/T1 Enumeration Type NO_V(NO_V), PAP_V(PAP_V), CHAP_V(CHAP_V) NO_V, PAP_V, CHAP_V None NO_V NO_V PPP link None Read & Write Y PPP link Interrupt the service until negotiate successfully again. Negotiation can succeed only when the configuration is consistent on the local and peer ends.
AUTHTYPE Validate protocol type BSC6900 ADD MPGRP(Optional) Verification protocol type upon PPP or MP link negotiation GBFD-118611GBFD-118622 Abis IP over E1/T1A IP over E1/T1 Enumeration Type NO_V(NO_V), PAP_V(PAP_V), CHAP_V(CHAP_V) NO_V, PAP_V, CHAP_V None NO_V None MP groupNone Read & Write Y BSC6900 Interrupt the service until negotiate successfully again. Negotiation can succeed only when the configuration is consistent on the local and peer ends.
AUTHTYPE Validate protocol type BSC6900 ADD BTSPPPLNK(Optional)ADD BTSMPGRP(Optional) Type of the validation protocol for the PPP link negotiation or MLPPP link negotiation GBFD-118611Abis IP over E1/T1 Enumeration Type NO_V, PAP_V, CHAP_V NO_V, PAP_V, CHAP_V None None None BTS None Read & Write Y PPP link Less than 5 minutes Negotiation can succeed only when the configuration is consistent on the local and peer ends.
AUTO Auto negotiation BSC6900 SET ETHPORT(Optional) Whether the self-negotiation mode is adopted 1. When the FG2 board is used and the port type is GE, the self-negotiation mode must be adopted.2. If the self-negotiation mode is adopted, the FE port rate, working mode and flow control mode must be in accord with the negotiation result. If the self-negotiation mode is not adopted, the FE port rate, working mode and flow control mode must be specified. Make sure that the specified attributes are the same as that of the peer. Otherwise, transmission failure must be incurred.3. If the self-negotiation mode is adopted on the local system, the peer must use the self-negotiation mode. None None Enumeration Type ENABLE, DISABLEENABLE, DISABLE None None ENABLE Ethernet port None Read & Write Y BSC6900 Interrupt the service until negotiate successfully again. The port can be set to the DOWN or UP state when this parameter is modified. If the negotiation modes on the local and peer end are not consistent, the service can be interrupted.
AUTOADDSRCON Add inter-subrack path automatically BSC6900 ADD BRD(Optional) Whether inter-subrack path be added automatically MRFD-210301Configuration Management Enumeration Type NO(NO), YES(YES) NO, YES None YES None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AUTOADJULTHHYSTF Auto Adjust UL TH and Hysteresis [F] BSC6900 SET GCELLCCAMR(Optional) Whether to allow automatic adjustment for the uplink threshold and hysteresis of full rate AMR call rates GBFD-115501AMR FR Enumeration Type NO(No), YES(Yes)NO, YES None None YES Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AUTOADJULTHHYSTH Auto Adjust UL TH and Hysteresis [H] BSC6900 SET GCELLCCAMR(Optional) Whether to allow automatic adjustment for the uplink threshold and hysteresis of half rate AMR call rates GBFD-115502AMR HR Enumeration Type NO(No), YES(Yes)NO, YES None None YES Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AutoGetBtsLogFlag Support Auto Obtaining of BTS Logs BSC6900 SET OTHSOFTPARA(Optional) Whether to enable the BSC to obtain BTS logs automatically GBFD-111202O&M of BTS Enumeration Type NO, YES NO, YES None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved If this parameter is set to YES, the BSC load is increased early in every morning.
AUTONEG Automatic Negotiation Mode BSC6900 SET BTSETHPORT(Optional) Whether to enable the auto-negotiation mode GBFD-118601Abis over IP Enumeration Type DISABLED(Disabled), ENABLED(Enabled) DISABLED, ENABLEDNone None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AUTOTYPE Work Mode for Auto Download Activation BSC6900 SET BTSAUTODLDACTINFO(Optional) Downloading and activation mode of the BTS GBFD-111202O&M of BTS Enumeration Type BTSAUTODLDACT(BTS Software Auto DL and ACT), TMUAUTOACT(TMU Software Auto ACT) BTSAUTODLDACT, TMUAUTOACT None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AUTOULKSW Auto Unlock Switch BSC6900 LCK SCHTSK(Optional) Auto unlock switch MRFD-210305Security Management Enumeration Type OFF, ON OFF, ON None ON None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AutoUnlockTime Auto Unlock Time BSC6900 SET PWDPOLICY(Optional) Length of the time after which the locked user is unlocked automatically MRFD-210305Security Management Interval Type 1~65535 1~65535 min None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AUTYPE administration unit type BSC6900 SET OPT(Optional) optical adaptation type between high-order path and multiplex section. None None Enumeration Type AU4(AU4), AU3(AU3) AU4, AU3 None None AU4 Channelized optical port None Read & Write Y Optical port If the mode is not consistent, will interrupt service until it is consistent. If the mode is not consistent, will interrupt service until it is consistent.
AVD1 Alarm Voltage Definition 1 BSC6900 SET BTSALM(Optional) Whether to trigger Boolean alarms at a high or low level. Each bit indicates whether to trigger the alarm associated with a specific Boolean at a high or low level. If the bit is set to 1, the Boolean alarm is triggered when the Boolean is at a high level. If the bit is set to 0, the Boolean alarm is triggered when the Boolean is at a low level. GBFD-111202O&M of BTS Interval Type 0~255 0~255 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AVD2 Alarm Voltage Definition 2 BSC6900 SET BTSALM(Optional) Whether to trigger Boolean alarms at a high or low level. Each bit indicates whether to trigger the alarm associated with a specific Boolean at a high or low level. If the bit is set to 1, the Boolean alarm is triggered when the Boolean is at a high level. If the bit is set to 0, the Boolean alarm is triggered when the Boolean is at a low level. GBFD-111202O&M of BTS Interval Type 0~255 0~255 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AVD3 Alarm Voltage Definition 3 BSC6900 SET BTSALM(Optional) Whether to trigger Boolean alarms at a high or low level. Each bit indicates whether to trigger the alarm associated with a specific Boolean at a high or low level. If the bit is set to 1, the Boolean alarm is triggered when the Boolean is at a high level. If the bit is set to 0, the Boolean alarm is triggered when the Boolean is at a low level. GBFD-111202O&M of BTS Interval Type 0~255 0~255 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AVD4 Alarm Voltage Definition 4 BSC6900 SET BTSALM(Optional) Whether to trigger Boolean alarms at a high or low level. Each bit indicates whether to trigger the alarm associated with a specific Boolean at a high or low level. If the bit is set to 1, the Boolean alarm is triggered when the Boolean is at a high level. If the bit is set to 0, the Boolean alarm is triggered when the Boolean is at a low level. This parameter is supported only by the following types of BTSs: BTS3006C and BTS3002E. GBFD-111202O&M of BTS Interval Type 0~255 0~255 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AVD5 Alarm Voltage Definition 5 BSC6900 SET BTSALM(Optional) Whether to trigger Boolean alarms at a high or low level. Each bit indicates whether to trigger the alarm associated with a specific Boolean at a high or low level. If the bit is set to 1, the Boolean alarm is triggered when the Boolean is at a high level. If the bit is set to 0, the Boolean alarm is triggered when the Boolean is at a low level. This parameter is supported only by the following types of BTSs: BTS3006C and BTS3002E. GBFD-111202O&M of BTS Interval Type 0~255 0~255 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AVer A Interface Tag BSC6900 SET BSCBASIC(Optional) Phase tag for GSM protocols supported by the A interface. The value of this parameter is chosen according to the A interface phase tag provided by the MSC. GBFD-111804A Interface Protocol Process Enumeration Type GSM_PHASE_1, GSM_PHASE_2, GSM_PHASE_2Plus GSM_PHASE_1, GSM_PHASE_2, GSM_PHASE_2Plus None None "GSM_PHASE_2" is recommended in common scenarios. If the BSC needs to support GPRS services, EDGE services, AMR services, eMLPP services, inter-RAT handover, and A over IP mode, "GSM_PHASE_2Plus" is recommended. BSC6900Generally, the value of this parameter is equal to "Um Interface Tag" and "Um Interface Tag". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AVL Alarm Valid Level Configuration BSC6900 SET BTSAPMUBP(Optional) Whether the Boolean alarm is triggered at the high level or low level.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. MRFD-210304Faulty Management Bit Field Type NO1, NO2, NO3, NO4, NO5, NO6, NO7, NO8 NO1, NO2, NO3, NO4, NO5, NO6, NO7, NO8 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AVL Alarm Valid Level Configuration BSC6900 SET BTSDPMUBP(Optional) This parameter consists of seven bits, each of which indicates whether the corresponding Boolean alarm is triggered at the low level or high level. The bit value 0 indicates that the alarm is triggered at the low level, and the bit value 1 indicates that tlhe alarm is triggered at the high level.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. MRFD-210304Faulty Management Bit Field Type NO1, NO2, LIGHT_ARR, NO4, NO5, NO6, NO7 NO1, NO2, LIGHT_ARR, NO4, NO5, NO6, NO7 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AVOL Alarm level BSC6900 SET ALMPORT(Optional) Alarm level for a digital port MRFD-210304Faulty Management Enumeration Type LOW(LOW), HIGH(HIGH) LOW, HIGH None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
AVOL Alarm VOL. BSC6900 SET BTSENVALMPORT(Optional) Alarm level. It is valid for the digital port. MRFD-210304Faulty Management Enumeration Type LOW(LOW), HIGH(HIGH) LOW, HIGH None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
B1B2SDTHRD B1B2 signal degraded threshold BSC6900 SET OPT(Optional) Threshold of B1 and B2 signal degrade None None Enumeration Type O1E3_R1E4(OCCUR:1E-3, RECOVERY:1E-4), O1E4_R1E5(OCCUR:1E-4, RECOVERY:1E-5), O1E5_R1E6(OCCUR:1E-5, RECOVERY:1E-6), O1E6_R1E7(OCCUR:1E-6, RECOVERY:1E-7), O1E7_R1E8(OCCUR:1E-7, RECOVERY:1E-8), O1E8_R1E9(OCCUR:1E-8, RECOVERY:1E-9), O1E9_R1E10(OCCUR:1E-9, RECOVERY:1E-10), O1E10_R1E11(OCCUR:1E-10, RECOVERY:1E-11), O1E11_R1E12(OCCUR:1E-11, RECOVERY:1E-12) O1E3_R1E4, O1E4_R1E5, O1E5_R1E6, O1E6_R1E7, O1E7_R1E8, O1E8_R1E9, O1E9_R1E10, O1E10_R1E11, O1E11_R1E12 None None None Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
B1B2SFTHRD B1B2 signal fail threshold BSC6900 SET OPT(Optional) Threshold of B1 and B2 signal failure None None Enumeration Type O1E3_R1E4(OCCUR:1E-3, RECOVERY:1E-4), O1E4_R1E5(OCCUR:1E-4, RECOVERY:1E-5), O1E5_R1E6(OCCUR:1E-5, RECOVERY:1E-6), O1E6_R1E7(OCCUR:1E-6, RECOVERY:1E-7), O1E7_R1E8(OCCUR:1E-7, RECOVERY:1E-8), O1E8_R1E9(OCCUR:1E-8, RECOVERY:1E-9), O1E9_R1E10(OCCUR:1E-9, RECOVERY:1E-10), O1E10_R1E11(OCCUR:1E-10, RECOVERY:1E-11), O1E11_R1E12(OCCUR:1E-11, RECOVERY:1E-12) O1E3_R1E4, O1E4_R1E5, O1E5_R1E6, O1E6_R1E7, O1E7_R1E8, O1E8_R1E9, O1E9_R1E10, O1E10_R1E11, O1E11_R1E12 None None None Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
B3SDTHRD B3 signal degraded threshold BSC6900 SET OPT(Optional) Threshold of B3 signal degrade None None Enumeration Type O1E4_R1E5(OCCUR:1E-4, RECOVERY:1E-5), O1E5_R1E6(OCCUR:1E-5, RECOVERY:1E-6), O1E6_R1E7(OCCUR:1E-6, RECOVERY:1E-7), O1E7_R1E8(OCCUR:1E-7, RECOVERY:1E-8), O1E8_R1E9(OCCUR:1E-8, RECOVERY:1E-9), O1E9_R1E10(OCCUR:1E-9, RECOVERY:1E-10), O1E10_R1E11(OCCUR:1E-10, RECOVERY:1E-11) O1E4_R1E5, O1E5_R1E6, O1E6_R1E7, O1E7_R1E8, O1E8_R1E9, O1E9_R1E10, O1E10_R1E11 None None None Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
B3SFTHRD B3 signal fail threshold BSC6900 SET OPT(Optional) Threshold of B3 signal failure None None Enumeration Type O1E4_R1E5(OCCUR:1E-4, RECOVERY:1E-5), O1E5_R1E6(OCCUR:1E-5, RECOVERY:1E-6), O1E6_R1E7(OCCUR:1E-6, RECOVERY:1E-7), O1E7_R1E8(OCCUR:1E-7, RECOVERY:1E-8), O1E8_R1E9(OCCUR:1E-8, RECOVERY:1E-9), O1E9_R1E10(OCCUR:1E-9, RECOVERY:1E-10), O1E10_R1E11(OCCUR:1E-10, RECOVERY:1E-11) O1E4_R1E5, O1E5_R1E6, O1E6_R1E7, O1E7_R1E8, O1E8_R1E9, O1E9_R1E10, O1E10_R1E11 None None None Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BACK8KCLKSW1 Switch of backplane LINE1 BSC6900 SET CLK(Optional)Switch of backplane LINE1 MRFD-210502BSC/RNC Clock Enumeration Type OFF(OFF), ON(ON) OFF, ON None None None Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved Each backplane board 8K clock has only one clock source. You are not allowed to turn on the same backplane board 8K clock switch for multiple interface boards.
BACK8KCLKSW2 Switch of backplane LINE2 BSC6900 SET CLK(Optional)Switch of backplane LINE2 MRFD-210502BSC/RNC Clock Enumeration Type OFF(OFF), ON(ON) OFF, ON None None None Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved Each backplane board 8K clock has only one clock source. You are not allowed to turn on the same backplane board 9K clock switch for multiple interface boards.
BackupPath Backup Path BSC6900 BKP LOGDB(Optional) Directory for saving the backup file GBFD-111203MRFD-210305 O&M of BSCSecurity Management String Type None 0~200 characters None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BACKUPPATH Path of Backup File BSC6900 BKP DB(Optional) Path (complete path) of the backup file. MRFD-210301Configuration Management String Type None 0~128 characters None None None BSC6900None Read & Write Not involved Not involved Not involved None
BADQUALDISCTHRES Bad Quality Disconnection Threshold BSC6900 SET GCELLSOFT(Optional) Quality threshold for determining that a call is disconnected because of poor quality. If the uplink quality or downlink quality in the measurement reports during the period of "Timer for Bad Quality DISC Statistic" is higher than the value of this parameter before the call is disconnected, you can infer that the call disconnection is due to poor quality. This parameter can be used to calculate the number of call disconnections due to poor quality. GBFD-111004Radio Dedicated Channel Management Interval Type 0~70 0~70 None None 55 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
bAdvEstDlTbf Support Advance Downlink TBF Establishment BSC6900 SET BSCPSSOFTPARA(Optional) Whether the downlink TBF can be established in advance. Downlink TBF establishment in advance indicates that the downlink TBF is established immediately after the MS establishes the uplink TBF rather than establishing the downlink TBF after the SGSN sends the data block. GBFD-114101GPRS Enumeration Type CLOSE(Close), LOCALTLLI(Local TLLI Opt), ALLTLLI(All TLLI Opt) CLOSE, LOCALTLLI, ALLTLLI None None ALLTLLI BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BAKDEVTAB BTS Interface Board Bar Code 2 BSC6900 ADD BTSESN(Optional) Bar code 2 of the interface board of the BTS None None String Type None 1~64 characters None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BAKIP Backup port IP address BSC6900 STR IPCHK(Optional) IP address of the backup port GBFD-118609IP Fault Detection Based on BFD IP Address Type None 0.0.0.0~255.255.255.255 None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved To modify this parameter, run "STP GATEWAYCHK" first and then "STR GATEWAYCHK".
BAKMASK Backup port mask BSC6900 STR IPCHK(Optional) Mask of the backup port GBFD-118609IP Fault Detection Based on BFD IP Address Type None 0.0.0.0~255.255.255.255 None None None Ethernet port None Read & Write N (No impact on the UE in idle mode) Not involved Not involved To modify this parameter, run "STP GATEWAYCHK" first and then "STR GATEWAYCHK".
BAKPWRSAVMETHOD Backup Power Saving Method BSC6900 SET BTSBAKPWR(Mandatory) Backup power saving method for the BTS. If this parameter is set to BYTRX, when the BTS switches from the mains to batteries, the BTS shuts down TRXs. If this parameter is set to BYPWR, when the BTS switches from the mains to batteries, the BTS decreases the power of TRXs. GBFD-111605Active Backup Power Control Enumeration Type BYTRX(Turn off TRX), BYPWR(Reduce Backup Power) BYTRX, BYPWR None None None BTS This parameter can work with "BTSPOWEROFFLOCKBCCH" in "SET BTSLOCKBCCH" to determine whether to shut down the TRX that carries the main BCCH. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BAKPWRSAVPOLICY Backup Power Saving Policy BSC6900 SET BTSBAKPWR(Optional) Backup power saving policy for the BTS. If this parameter is set to BYCOVER, when the BTS switches from the mains to batteries, the BTS shuts down certain TRXs and after a while decreases the power of the TRX that carries the main BCCH. If this parameter is set to BYCAP, when the BTS switches from the mains to batteries, the BTS decreases the power of the TRX that carries the main BCCH and after a while shuts down certain TRXs. If this parameter is set to BYSAVING, when the BTS switches from the mains to batteries, the BTS shuts down certain TRXs and meanwhile decreases the power of the TRX that carries the main BCCH. GBFD-111605Active Backup Power Control Enumeration Type BYCOVER(Cover Priority), BYCAP(Capability Priority), BYSAVING(Saving Priority) BYCOVER, BYCAP, BYSAVING None None BYCOVER BTS This parameter is valid only when "BAKPWRSAVMETHOD" is set to BYPWR. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BANDINDICATOR1900 High Band Indicator of Cell 1900 BSC6900 SET GCELLSOFT(Optional) Whether the cells at the 1900 frequency support high frequency 1900 GBFD-114401Multi-band Sharing One BSC Interval Type 0~1 0~1 None None 1 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BANDINDICATOR850 High Band Indicator of Cell 850 BSC6900 SET GCELLSOFT(Optional) Whether the cells at the 850 frequency support high frequency 1900 GBFD-114401Multi-band Sharing One BSC Interval Type 0~1 0~1 None None 1 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BANDINDICATOR900 High Band Indicator of Cell 900 BSC6900 SET GCELLSOFT(Optional) Whether the cells at the 900 frequency support high frequency 1900 GBFD-114401Multi-band Sharing One BSC Interval Type 0~1 0~1 None None 1 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BANTIME Forbidden time after MAX Times BSC6900 SET GCELLHOAD(Optional) Duration in which intra-cell handover is forbidden after the number of consecutive intra-cell handovers reaches the maximum. Intra-cell handover can be conducted again only after this duration. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 1~200 1~200 s None 20 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BARCODLST Cabinet Bar Code List BSC6900 SET BTSRACKBC(Mandatory) List of bar codes of all the cabinets in the BTS GBFD-111202O&M of BTS String Type None 1~80 characters None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BASEBTSID Reference BTS Index BSC6900 ADD AISSCFG(Mandatory) The reference BTS must support the Um interface software synchronization. GBFD-118201Soft-Synchronized Network Interval Type 0~2047 0~2047 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None.
BASETEMPERATURE Temperature Basis for Compensation BSC6900 SET BTSAPMUBP(Optional) Number of the temperature sensor corresponding to a battery group. You can choose sensor 1 (Battery1Temp) or sensor 2 (Battery2Temp). If you choose sensor 1, the system automatically uses sensor 1 to control the temperature of the battery group and performs temperature compensation, high temperature protection, and overtemperature alarm accordingly. The system handling principles are the same if you choose sensor 2. For the APM4815 boards, this parameter can only be configured as "Battery1Temp".In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. GBFD-111202O&M of BTS Enumeration Type Battery1Temp(Battery 1 Temperature), Battery2Temp(Battery 2 Temperature) Battery1Temp, Battery2Temp None None For APM4815 boards, the value of this parameter is always "Battery1Temp". BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BASETEMPERATURE Temperature Basis for Compensation BSC6900 SET BTSDPMUBP(Optional) Number of the temperature sensor corresponding to a battery group.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. GBFD-111202O&M of BTS Enumeration Type Battery1Temp(Battery 1 Temperature), Battery2Temp(Battery 2 Temperature) Battery1Temp, Battery2Temp None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BATTCAPACITY Battery Capacity BSC6900 SET BTSDPMUBP(Optional) Battery capacity.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. GBFD-111202O&M of BTS Interval Type 30~1000 30~1000 Ah None 50 BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BATTENABLEDIN Battery Configuration Enabled BSC6900 SET BTSDPMUBP(Optional) Whether the configuration of external battery is allowed. The value "YES" indicates that the external battery can be configured, and the value "NO" indicates that the external battery cannot be configured.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. GBFD-111202O&M of BTS Enumeration Type NO(NO), YES(YES) NO, YES None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BATTERYDISCHARGEDEPTH Battery discharge depth BSC6900 SET BTSAPMUBP(Optional)SET BTSDPMUBP(Optional) Allowed percentage of the battery discharging. After the AC power supply is cut and the power of the battery is discharged by the value of this parameter, the diesel engine is started to supply the power. GBFD-111202O&M of BTS Interval Type 0~90 0~90 per cent None 50 BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BATTTYPE Battery Type BSC6900 SET BTSDPMUBP(Optional) Battery type.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. GBFD-111202O&M of BTS Enumeration Type NO_BAT(No Storage Battery), LEADACID_BAT(Lead Acid Battery), LITHIUM_BAT(Lithium Battery) NO_BAT, LEADACID_BAT, LITHIUM_BAT None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BBAPSRVPN BBAP service listening port No. BSC6900 SET SCTPSRVPORT(Optional) Number of the BBAP service listening port None None Interval Type 1024~65535 1024~65535 None None 58000 SCTP linkNone Read & Write Y SCTP link The services are interrupted until the SCTP link is working normally. The parameter modification should be negotiated with the peer end, and the BSC should be reset after the modification. It is recommended that this parameter should not be modified when the system is running.
BBDIF Up Down Balance Basic Difference BSC6900 SET GTRXRLALM(Optional) Reference difference between uplink and downlink levels. This parameter works with "Up down balance floating fange" to count uplink-downlink imbalances. GBFD-110801GBFD-110802 Processing of Measurement ReportPre-processing of Measurement Report Interval Type 0~254 0~254 None None 8 TRX This parameter is valid only when "WLNKALMFLAG" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BC Battery Capcity BSC6900 SET BTSAPMUBP(Optional) Battery capacity. The battery capacity should be set according to the vendor specification. If it is improperly configured, the battery life may be shortened.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. GBFD-111202O&M of BTS Interval Type 0~3000 0~3000 Ah 36 None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BCC BCC BSC6900 ADD GCELL(Optional) BCC of a cell MRFD-210301Configuration Management Interval Type 0~7 0~7 None None None Cell None Read & Write Y Cell Less than 5 minutes None
BCC BCC BSC6900 ADD GEXT2GCELL(Mandatory) Base station color code (BCC) of a cell, provided by the network planning department. It is used for differentiating the neighbor cells around using a same BCCH frequency. A BCC and a network color code (NCC) compose a base station identity code (BSIC). MRFD-210301Configuration Management Interval Type 0~7 0~7 None None None Cell None Read & Write Y Cell Less than 5 minutes None
BCC BCC BSC6900 ADD GCELLQUICKSETUP(Optional) BTS color code. It uniquely identifies different BTSs that are adjacent and use the same TRX. GBFD-510702Compact BTS Automatic Capacity Planning Interval Type 0~7 0~7 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BCCH BCCH FD BSC6900 ADD GEXT2GCELL(Mandatory) BCCH frequency of the cell MRFD-210301Configuration Management Interval Type 0~1023 0~1023 None None None Cell None Read & Write Y Cell Less than 5 minutes None
BCCHFREQ Main BCCH Frequency BSC6900 ADD GCELLQUICKSETUP(Mandatory) Frequency of the BCCH TRX GBFD-510702Compact BTS Automatic Capacity Planning Interval Type 0~1023 0~1023 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BCCHTRXHP Frequency hopping mode of BCCH TRX BSC6900 SET GCELLHOPQUICKSETUP(Mandatory) Frequency hopping mode of the TRX that carries the BCCH GBFD-113701Frequency Hopping (RF hopping, baseband hopping) Enumeration Type NO_Hop(No hop), Hop(Hop) NO_Hop, Hop None None None Cell None Read & Write Y Cell Less than 5 minutes None
BCCONGESTALMBOUND BC Congestion Alarm Threshold BSC6900 SET BSCPSSOFTPARA(Optional) Threshold for reporting the BC congestion alarm. When the BC congestion level exceeds the threshold, the BC congestion alarm is reported. GBFD-510002Gb Over FR Interval Type 0~100 0~100 per cent None 80 BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BCCONGESTRESALMBOUND BC Congestion Restore Alarm Threshold BSC6900 SET BSCPSSOFTPARA(Optional) Threshold for clearing the BC congestion alarm. When the BC congestion level is below the threshold, the BC congestion alarm is cleared. GBFD-510002Gb Over FR Interval Type 0~100 0~100 per cent None 60 BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BCDSCP DSCP of BG[QoS] BSC6900 SET BSCPSTCDSCPMAP(Optional) DSCP corresponding to the background service. GBFD-118603Gb over IP Interval Type 0~63 0~63 None None 0 BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BCID BC Identifier BSC6900 STR FRPORTLOOP(Mandatory)BLK BC(Mandatory)ADD BC(Mandatory)ADD NSVC(Mandatory) Identifies one BC at the same port. The BCID's value range of PEUa board is 0~255 and that of POUc board is 0~511. GBFD-510002Gb Over FR Interval Type 0~511 0~511 None None None BC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BCLC Battery Current Limiting Coefficient BSC6900 SET BTSAPMUBP(Optional) Current limit coefficient of the battery. The maximum charging current equals the value of "Battery Current Limiting Coefficient" multiplexed by "Battery Capacity". If the charging current is 5 A higher than the maximum charging current, the overcharge alarm is reported.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. GBFD-111202O&M of BTS Interval Type 5~25 5~25 per cent None If "Power System Type" is "APM30", the recommended value is "7". For other Power System Type, the recommended value is "15". BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BCV Boost-Charging Voltage BSC6900 SET BTSAPMUBP(Optional) Boost-Charging Voltage. See the vendor specification for the setting of this parameter.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. GBFD-111202O&M of BTS Interval Type 433~576 43.3~57.6 (step: 0.1) V None 565 BTS The value of this parameter must be greater than "Float charging voltage" and at least two volts lower than "DC Voltage Upper Threshold". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BE Battery Configuration Enabled BSC6900 SET BTSAPMUBP(Optional) Whether the configuration of external battery is allowed.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. GBFD-111202O&M of BTS Enumeration Type NO(NO), YES(YES) NO, YES None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BEARP1PRIWEIGHT BestEffort-ARP1 Priority Weight BSC6900 SET GCELLPSCHM(Optional) ARP1 priority in the BE service. ARP1 priority weight determines the number of the budget blocks and the block scheduling priority. GBFD-119902QoS ARP&THP Interval Type 1~10 1~10 None None 8 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BEARP2PRIWEIGHT BestEffort-ARP2 Priority Weight BSC6900 SET GCELLPSCHM(Optional) ARP2 priority in the BE service. ARP2 priority weight determines the number of the budget blocks and the block scheduling priority. GBFD-119902QoS ARP&THP Interval Type 1~10 1~10 None None 4 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BEARP3PRIWEIGHT BestEffort-ARP3 Priority Weight BSC6900 SET GCELLPSCHM(Optional) ARP3 priority in the BE service. ARP3 priority weight determines the number of the budget blocks and the block scheduling priority. GBFD-119902QoS ARP&THP Interval Type 1~10 1~10 None None 2 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BEARTYPE DSP bear type BSC6900 ADD N7DPC(Mandatory) DSP bearer type. It indicates whether the lower layer bearer is the MTP3 or M3UA. None None Enumeration Type MTP3(MTP3), M3UA(M3UA), MTP3_M3UA(MTP3_M3UA) MTP3, M3UA, MTP3_M3UA None None None SCCP None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
BEARTYPE Link Bear type BSC6900 ADD MTP3LNK(Mandatory) Link bearer type. None None Enumeration Type MTP2(MTP2), SAAL(SAAL) MTP2, SAAL None None None MTP3 linkNone Read & Write Not involved Not involved Not involved The parameter cannot be modified.
BEATSENDINGDIS Interval for Sending Heartbeat BSC6900 SET GBSCREDGRP(Optional) Time interval for sending a handshake message between BSCs. GBFD-113725BSC Node Redundancy Interval Type 1~60 1~60 s 1 1 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BEPPERIOD Bep Period BSC6900 SET GCELLEGPRSPARA(Optional) Average period for sending the measurement report over the EGPRS channel. GBFD-114201EGPRS Interval Type 0~10 0~10 None None 5 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BESTTDDCELLNUM Best TDD Cell Number BSC6900 SET GCELLCCUTRANSYS(Optional) Number of UTRAN TDD cells that should be included in measurement report GBFD-114302GSM/TD-SCDMA Interoperability Interval Type 0~3 0~3 None None 1 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BET3GHOEN Better 3g cell ho allowed BSC6900 SET GCELLHOUTRANFDD(Optional)SET GCELLHOUTRANTDD(Optional) Whether to enable the algorithm for the handover to a better 3G cell GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Enumeration Type NO(No), YES(Yes)NO, YES None None NO Cell This parameter is valid only when "INTERRATOUTBSCHOEN" in "SET GCELLHOBASIC" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BETTERCELLHOEN Better cell handover enable BSC6900 SET GCELLHOBASIC(Optional) Whether to enable the algorithm for the handover to a better cell GBFD-510501HUAWEI II Handover Enumeration Type NO(No), YES(Yes)NO, YES None None YES Cell This parameter is valid only when "HOCTRLSWITCH" is set to HOALGORITHM2. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BETTERCELLLASTTIME Better Cell HO Valid Time BSC6900 SET GCELLHOBASIC(Optional) According to the P/N rule, if the conditions for the handover to a better cell due to interference are met for P seconds within N seconds, the handover is triggered.This parameter specifies the number P. GBFD-510501HUAWEI II Handover Interval Type 1~16 1~16 s None 2 Cell This parameter is valid only when "BETTERCELLHOEN" is set to YES and "HOCTRLSWITCH" is set to HOALGORITHM2. The following condition must be met: "BETTERCELLSTATTIME" >= "BETTERCELLLASTTIME". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BETTERCELLSTATTIME Better Cell HO Watch Time BSC6900 SET GCELLHOBASIC(Optional) According to the P/N rule, if the conditions for the handover to a better cell due to interference are met for P seconds within N seconds, the handover is triggered.This parameter specifies the number N. GBFD-510501HUAWEI II Handover Interval Type 1~16 1~16 s None 3 Cell This parameter is valid only when "BETTERCELLHOEN" is set to YES and "HOCTRLSWITCH" is set to HOALGORITHM2. The following condition must be met: "BETTERCELLSTATTIME" >= "BETTERCELLLASTTIME". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BFDDETECTCOUNT detect multiplier of BFD packet BSC6900 STR IPCHK(Optional) Timeout times of the BFD packet. If several consecutive BFD packets are not received, the BFD session is set to the DOWN state. GBFD-118609IP Fault Detection Based on BFD Interval Type 3~10 3~10 None 3 3 Current BFD session None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
BFDSN BFD session No. BSC6900 ADD BTSBFD(Mandatory)ADD BTSIPRTBIND(Mandatory) BFD Session No. GBFD-118609IP Fault Detection Based on BFD Interval Type 1~2 1~2 None None None Current BFD session None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BFRANGE Up Down Balance Floating Range BSC6900 SET GTRXRLALM(Optional) Allowed fluctuation of the difference between uplink and downlink levels relative to the reference difference. If the difference between uplink and downlink levels is outside the fluctuation range, the uplink and downlink are considered imbalanced.For example, assume that the Up Down Balance Basic Difference is set to 8 and that the Up Down Balance Floating Range is set to 30. If the difference between uplink and downlink levels is greater than 38 (= 8 + 30) or less than -22 (= 8 - 30), the uplink and downlink are considered imbalanced. If the difference between uplink and downlink levels is between -22 and 38, the uplink and downlink are considered balanced. GBFD-110801GBFD-110802 Processing of Measurement ReportPre-processing of Measurement Report Interval Type 10~254 10~254 None None 30 TRX This parameter is valid only when "WLNKALMFLAG" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BHPREPOLICY Switchback Policy of Baseband FH Mutual Aid BSC6900 SET GCELLCCACCESS(Optional) Mutual-aid changeback policy of baseband frequency hopping (FH). If multiple TRXs in a baseband FH group are faulty and changeback is needed after mutual aid of the baseband FH TRXs occurs: If you choose ALL, mutual-aid changeback is implemented after all the TRXs in the FH group recover; if you choose PART, as long as any of the faulty TRXs recovers, it is changed back at once and added to the FH group. GBFD-113801TRX Cooperation Enumeration Type ALL(All), PART(Part) ALL, PART None None ALL Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BITOFFSET In Frame Bit Offset [1/8 bit] BSC6900 SET BTSEXCURSION(Mandatory)SET BSCSYNCOFF(Mandatory) Bit offset in the frame of the BTS clock. GBFD-118201Soft-Synchronized Network Interval Type -10000~10000 -10000~10000 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None.
BKGARP1PRIWEIGHT Background-ARP1 Priority Weight BSC6900 SET GCELLPSCHM(Optional) ARP1 priority in the Background service. ARP1 priority weight determines the number of the budget blocks and the block scheduling priority. GBFD-119902QoS ARP&THP Interval Type 1~10 1~10 None None 4 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BKGARP2PRIWEIGHT Background-ARP2 Priority Weight BSC6900 SET GCELLPSCHM(Optional) ARP2 priority in the Background service. ARP2 priority weight determines the number of the budget blocks and the block scheduling priority. GBFD-119902QoS ARP&THP Interval Type 1~10 1~10 None None 2 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BKGARP3PRIWEIGHT Background-ARP3 Priority Weight BSC6900 SET GCELLPSCHM(Optional) ARP3 priority in the Background service. ARP3 priority weight determines the number of the budget blocks and the block scheduling priority. GBFD-119902QoS ARP&THP Interval Type 1~10 1~10 None None 1 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BLKFILTERSW Alarm switch of blinking filter BSC6900 SET ALMBLKSW(Optional) Base Station Controller alarm blink filter switch MRFD-210304Faulty Management Enumeration Type DISABLE(Disable), ENABLE(Enable) DISABLE, ENABLE None None None BSC6900If you set "Switch of stat blinking alarm" to "ENABLE", you need to set "Alarm switch of blinking filter" to "ENABLE". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BLKPRD Alarm blink threshold BSC6900 SET ALMBLKPARA(Optional) Alarm blink filter threshold. When the interval between the generation and clearance of an alarm is equal to or smaller than the alarm blink filter threshold, the alarm is filtered and not reported to the NMS. MRFD-210304Faulty Management Interval Type 0~65534 0~65534 s None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved To disable the alarm blink filter function, set this parameter to "0". To enable the alarm blink filter function, set this parameter to a value greater than 0 and turn on the alarm blink filter switch. See "SET ALMBLKSW" for setting the alarm blink filter switch.
BLKSTATPRD Observing time window of statistical alarm BSC6900 SET ALMBLKSW(Optional) Measurement period of filtered Base Station Controller alarms MRFD-210304Faulty Management Interval Type 60~65534 60~65534 s None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved To enable the alarm blink filter function, set "Alarm switch of blinking filter" and "Switch of stat blinking alarm" to "ENABLE".
BLKSTATSW Switch of statistics blinking alarm BSC6900 SET ALMBLKSW(Optional) Switch controlling whether to perform statistics of Base Station Controller alarms MRFD-210304Faulty Management Enumeration Type DISABLE(Disable), ENABLE(Enable) DISABLE, ENABLE None None None BSC6900If you set "Switch of stat blinking alarm" to "ENABLE", you need to set "Alarm switch of blinking filter" to "ENABLE". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BLOCKRETRY Block Retry BSC6900 SET BSCNSPARA(Optional) Retry times after the peer response timer expires during NSVC blocking. GBFD-510002Gb Over FR Interval Type 1~6 1~6 None None 4 BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BLOCKTIMER Block Timer BSC6900 SET BSCNSPARA(Optional) Duration of the peer response timer during NSVC blocking. GBFD-510002Gb Over FR Interval Type 1~120 1~120 s None 10 BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BMPN BM Port No BSC6900 ADD ATERCONPATH(Mandatory) BM port No. where one end of the ATER connection channel is located None None Interval Type 0~335 0~335 None None None Transport channel None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
BMSN BM Slot No BSC6900 ADD ATERCONPATH(Mandatory) BM slot No. where one end of the ATER connection channel is located None None Interval Type 0~5,8~27 0~5, 8~27 None None None Transport channel None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
BMSRN BM Subrack No BSC6900 ADD ATERCONPATH(Mandatory) BM subrack No. where one end of the ATER connection channel is located None None Interval Type 0~11 0~11 None None None Transport channel None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
BMTCFCTimerLen Timer Length of BM-TC Flow Control BSC6900 SET BSCTMR(Optional) Duration of the flow control protection timer enabled during the flow control between the TCS and the MPS/EPS subracks GBFD-111705GSM Flow Control Interval Type 0~5000 0~5000 s None 1000 BSC6900This parameter is valid when "BMTCFFLAG" in the "SET BSCFCPARA" command is set to ON. Read & Write N (No impact on the UE in idle mode) Not involved Not involved If the value of this parameter is too small, the SCUs of the TC subrack may remain congested. If the value is too large, the call failure rate may retain a higher value for a longer time.
BORROWDEVIP Borrow DevIP BSC6900 ADD PPPLNK(Mandatory)ADD MPGRP(Mandatory) Whether the device address is borrowed by the local address. If this parameter is set to YES, it indicates that the device IP is borrowed; otherwise, the device IP is not borrowed. GBFD-118611GBFD-118622 Abis IP over E1/T1A IP over E1/T1 Enumeration Type NO(NO), YES(YES) NO, YES None None No MP groupNone Read & Write Not involved Not involved Not involved The parameter cannot be modified.
boxflg To Alarm Box Flag BSC6900 SET BOXRPT(Mandatory) Whether to report the alarm to the alarm box MRFD-210304Faulty Management Enumeration Type nonrpt(Not Report), rpt(Report) nonrpt, rpt None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BP1 Position of Break Point 1 BSC6900 SET BTSBREAKPOINT(Optional) Position of break point 1 in an RXU chain. The number of break points must not be greater than the number of RXU boards in the RXU chain. GBFD-111202O&M of BTS Enumeration Type 0(0), 1(1), 2(2), 3(3), 4(4), 5(5), 6(6), NULL(NULL) 0, 1, 2, 3, 4, 5, 6, NULL None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BP2 Position of Break Point 2 BSC6900 SET BTSBREAKPOINT(Optional) Position of break point 2 in an RXU chain. The number of break points must not be greater than the number of RXU boards in the RXU chain. GBFD-111202O&M of BTS Enumeration Type 0(0), 1(1), 2(2), 3(3), 4(4), 5(5), 6(6), NULL(NULL) 0, 1, 2, 3, 4, 5, 6, NULL None None None BTS The value of this parameter must be greater than or equal to "Position of Break Point 1". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BQHOEN BQ HO Allowed BSC6900 SET GCELLHOBASIC(Optional) Whether to enable the bad quality (BQ) handover algorithm. Whether to trigger BQ handover depends on the uplink and downlink transmit quality (measured by using BER). If the uplink or downlink BQ exceeds the BQ handover threshold, emergency BQ handover is triggered. The possible causes of BER increase (or quality degradation) include too low signal power and channel interference. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Enumeration Type NO(No), YES(Yes)NO, YES None None YES Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BQLASTTIME BQ HO valid time BSC6900 SET GCELLHOBASIC(Optional) According to the P/N rule, if the conditions for emergency BQ handover are met in P of N measurement reports, the handover is triggered.This parameter specifies the number P. GBFD-510501HUAWEI II Handover Interval Type 1~16 1~16, step:0.5 s None 1 Cell This parameter is valid only when "BQHOEN" is set to YES and "HOCTRLSWITCH" is set to HOALGORITHM2. The following condition must be met: "BQSTATTIME" >= "BQLASTTIME". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BQMARGIN BQ HO Margin BSC6900 ADD G2GNCELL(Optional) If ("downlink level of the neighbor cell after filtering" - "downlink level of the serving cell (after power control compensation)") > ("Inter-cell HO Hysteresis" - "BQ HO Margin" + 64), the BQ handover to the neighbor cell is triggered. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 0~127 0~127 dB None 69 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved When the M900/M1800 BSC is upgraded to BSC6000, this parameter needs to be set to 69. If this parameter is not set to 69 in this case, the handover algorithm supported by this parameter is invalid.
BQSTATTIME BQ HO watch time BSC6900 SET GCELLHOBASIC(Optional) According to the P/N rule, if the conditions for emergency BQ handover are met in P of N measurement reports, the handover is triggered.This parameter specifies the number N. GBFD-510501HUAWEI II Handover Interval Type 1~16 1~16, step:0.5 s None 1 Cell This parameter is valid only when "BQHOEN" is set to YES and "HOCTRLSWITCH" is set to HOALGORITHM2. The following condition must be met: "BQSTATTIME" >= "BQLASTTIME". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BRDCLASS Board Class BSC6900 STR BKP(Mandatory) Classes of boards classified according to function modules MRFD-210301Configuration Management Enumeration Type SCU, GCU, XPU, INT, TNU SCU, GCU, XPU, INT, TNU None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BRDCLASS Board Class BSC6900 ADD BRD(Mandatory) Classes of boards classified according to function modules MRFD-210301Configuration Management Enumeration Type INT, DPU, XPU, TNU, OMU, SAU INT, DPU, XPU, TNU, OMU, SAU None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BRDCLASS Board Class BSC6900 SET FCSW(Mandatory)SET FCCPUTHD(Mandatory)SET FCMSGQTHD(Mandatory)SET CPUTHD(Mandatory) Classes of boards classified according to function modules MRFD-210301Configuration Management Enumeration Type SCU, GCU, XPU, DPU, INT, TNU SCU, GCU, XPU, DPU, INT, TNU None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BRDNO Board No. BSC6900 STR BTSLOG(Mandatory) Number of the board GBFD-111202O&M of BTS Interval Type 0~72 0~72 None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BRDNO Board No. BSC6900 STR BTSVSWRTST(Optional) Number of the RF front-end board in the BTS GBFD-111202O&M of BTS Interval Type 0~47 0~47 None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BRDRXBW Receive Bandwidth BSC6900 ADD BTSBRDCAP(Mandatory)ADD BTSRXUBRD(Optional) Threshold of the board RX bandwidth. GBFD-111202O&M of BTS Interval Type 0~1000 0~100 (step: 0.1) kbit/s None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BRDSWTYPE BTS Board Software Type BSC6900 LOD BTSSW(Mandatory) Software type of the BTS board GBFD-111202O&M of BTS Enumeration Type DATM_MAIN, DATU_MAIN, DDPM_MAIN, DDPU_MAIN, DDRM_MAIN, DEMU_MAIN, DFCU_MAIN, DGPS_MAIN, DHEU_MAIN, DOMU_MAIN, DPMU_MAIN, DPTU_MAIN, DRFU_MAIN, DRFUBOOT_MAIN, DRRU_MAIN, DRRUBOOT_MAIN, DRU_MAIN, DTCU_MAIN, DTMU_MAIN, DTRU_MAIN, ETR_MAIN, FMU_MAIN, FMUA_MAIN, GATM_MAIN, GTMU_MAIN, IASU_MAIN, IOMU_MAIN, MFU_3001C, MMU_3001C, MRRU_MAIN, MTR_MAIN, NFCB_MAIN, PBU_MAIN, QTRU_MAIN, TMU_MAIN, TRX_MAIN, GRRU_MAIN, BTS3900B_MAIN, BTS3900BBOOT_MAIN, MRFU_MAIN, GRFU_MAIN, MRRUBOOT_MAIN, MRFUBOOT_MAIN, USCU_MAIN, BTS3900E_MAIN, BTS3900EBOOT_MAIN, BOOTROM_PCK, UBRI_MAIN DATM_MAIN, DATU_MAIN, DDPM_MAIN, DDPU_MAIN, DDRM_MAIN, DEMU_MAIN, DFCU_MAIN, DGPS_MAIN, DHEU_MAIN, DOMU_MAIN, DPMU_MAIN, DPTU_MAIN, DRFU_MAIN, DRFUBOOT_MAIN, DRRU_MAIN, DRRUBOOT_MAIN, DRU_MAIN, DTCU_MAIN, DTMU_MAIN, DTRU_MAIN, ETR_MAIN, FMU_MAIN, FMUA_MAIN, GATM_MAIN, GTMU_MAIN, IASU_MAIN, IOMU_MAIN, MFU_3001C, MMU_3001C, MRRU_MAIN, MTR_MAIN, NFCB_MAIN, PBU_MAIN, QTRU_MAIN, TMU_MAIN, TRX_MAIN, GRRU_MAIN, BTS3900B_MAIN, BTS3900BBOOT_MAIN, MRFU_MAIN, GRFU_MAIN, MRRUBOOT_MAIN, MRFUBOOT_MAIN, USCU_MAIN, BTS3900E_MAIN, BTS3900EBOOT_MAIN, BOOTROM_PCK, UBRI_MAIN None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BRDTXBW Forward bandwidth BSC6900 ADD BTSBRDCAP(Mandatory)ADD BTSRXUBRD(Optional) Threshold of the board TX bandwidth. GBFD-111202O&M of BTS Interval Type 0~1000 0~100 (step: 0.1) kbit/s None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BRDTYPE Board Type BSC6900 ADD BRD(Optional) Type of the board MRFD-210301Configuration Management Enumeration Type PEUa, AEUa, FG2a, GOUa, AOUa, POUa, UOIa, EIUa, OIUa, AOUc, POUc, UOIc, FG2c, GOUc, SPUa, XPUa, SPUb, XPUb, DPUa, DPUb, DPUc, DPUd, DPUe, TNUa, OMUa, OMUb, SAUa PEUa, AEUa, FG2a, GOUa, AOUa, POUa, UOIa, EIUa, OIUa, AOUc, POUc, UOIc, FG2c, GOUc, SPUa, XPUa, SPUb, XPUb, DPUa, DPUb, DPUc, DPUd, DPUe, TNUa, OMUa, OMUb, SAUa None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BRDTYPE Board Type BSC6900 SET DPUBRDTYPE(Mandatory) Type of the board MRFD-210301Configuration Management Enumeration Type DPUa, DPUc DPUa, DPUc None None None Board None Read & Write Y BSC6900 Less than 5 minutes None
BRDTYPE Board type. BSC6900 SET ETHPORT(Mandatory) Board type None None Enumeration Type FG2a, GOUa, FG2c, GOUc FG2a, GOUa, FG2c, GOUc None None None Ethernet port None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
BRDTYPE Board type BSC6900 ADD PPPLNK(Mandatory) Board type GBFD-118611GBFD-118622 Abis IP over E1/T1A IP over E1/T1 Enumeration Type PEUa, POUa, UOIa, POUc PEUa, POUa, UOIa, POUc None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BRDTYPE Board type BSC6900 ADD MPGRP(Mandatory)ADD MPLNK(Mandatory) Board type GBFD-118611GBFD-118622 Abis IP over E1/T1A IP over E1/T1 Enumeration Type PEUa, POUa, POUc PEUa, POUa, POUc None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BrdType Board Type BSC6900 ADD BTSBRDCAP(Mandatory) Type of the new RXU board. GBFD-111202O&M of BTS Enumeration Type MRRU, GRRU, MRFU, GRFU, BTS3900E MRRU, GRRU, MRFU, GRFU, BTS3900E None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BRDTYPE Board Type BSC6900 STR BTSLOG(Mandatory) Type of the board. The type can be TMU/DTMU, DTRU, DPTU, QTRU, MRRU, GRRU, BTS3900B, MRFU, GRFU, BTS3900E, DRFU, DRRU, or UBRI. GBFD-111202O&M of BTS Enumeration Type TMU(TMU/DTMU), DTRU(DTRU), DPTU(DPTU), QTRU(QTRU), MRRU(MRRU), GRRU(GRRU), BTS3900B(BTS3900B), MRFU(MRFU), GRFU(GRFU), BTS3900E(BTS3900E), DRFU(DRFU), DRRU(DRRU), UBRI(UBRI) TMU, DTRU, DPTU, QTRU, MRRU, GRRU, BTS3900B, MRFU, GRFU, BTS3900E, DRFU, DRRU, UBRI None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BREAKTIME Ring II Wait Time Before Switch BSC6900 SET BTSRINGATTR(Optional) To avoid intermittent blinking, the switchover cannot be performed over a certain period of time when the OML is disconnected. That period of time is specified as ring II wait time before switch. GBFD-117802Fast Ring Network Switch Interval Type 0~255 0~255 s None None BTS The setting of this parameter must meet the following condition: "FallBack Start Time" > "Ring II Wait Time Before Switch" + "Ring II Try Rotating Duration Time". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BROADCASTCONTENT Broadcast Content BSC6900 SET GCELLSBC(Optional) Contents of a cell broadcast message GBFD-113602Simplified Cell Broadcast String Type None 1~80 characters None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BROADCASTINTERVAL Broadcast Interval BSC6900 SET GCELLSBC(Optional) Time interval for a cell broadcast message GBFD-113602Simplified Cell Broadcast Interval Type 2~3600 2~3600 s None 60 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BS Backup Style BSC6900 BKP LOGDB(Optional) Backup mode of the log. If "ENTIRE" is selected, all logs in the current database are backed up. If "INCREMENTAL" is selected, the logs generated after last backup are backed up. GBFD-111203MRFD-210305 O&M of BSCSecurity Management Enumeration Type ENTIRE(Entire Backup), INCREMENTAL(Incremental Backup) ENTIRE, INCREMENTAL None INCREMENTALNone RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BSAGBLKSRES CCCH Blocks Reserved for AGCH BSC6900 SET GCELLIDLEBASIC(Optional) BS-AG-BLKS-RES, indicating the number of the CCCH message blocks reserved for the AGCH. After the CCCHs are configured, the value of this parameter indicates actually the seizure rates of the AGCHs and the PCHs over the CCCHs. GBFD-111003Radio Common Channel Management Interval Type 0~7 0~7 None None 1 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved As defined in the protocol, the value of this parameter cannot be 0 in the following cases:The BSC needs to send system messages over the extended BCHs. CBCHs are configured.When the GSMR is enabled, NCHs are configured.
BSCDPC External BSC DPC BSC6900 ADD EXTBSC(Mandatory) DPC of the external BSC, which is used for inter-BSC communication. This parameter can be represented in decimal, hexadecimal, and binary. By default, this parameter is represented in decimal. To represent this parameter in hexadecimal, precede this parameter value with H'. To represent this parameter in binary, precede this parameter value with B'. GBFD-118602A over IP Interval Type 1~16777215 1~16777215 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BSCDynSwitchTrxPAAllow Allow Dynamic Shutdown Trx by BSC BSC6900 SET BSCDSTPA(Optional) Whether to enable the BSC to shut down the power amplifier of a TRX dynamically GBFD-111602TRX Power Amplifier Intelligent Shutdown Enumeration Type NO(No), YES(Yes)NO, YES None None NO BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
5/5/2014
Confidential Information of Huawei.
No Spreading without Permission
Page4of42
226347869.xls.ms_office Security Level:
BSCFLAG BSC Flag BSC6900 BLK ACIC(Mandatory)ADD AE1T1(Mandatory) It indicates whether the A interface E1/T1 is the primary BSC or secondary BSC. GBFD-111803A Interface Circuit Management Enumeration Type MAINBSC(MAIN BSC), SUBBSC(SUB BSC) MAINBSC, SUBBSC None None None E1/T1 linkNone Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BSCGATEWAYIP BSC GateWay IP BSC6900 ADD GCBSADDR(Mandatory) Gateway IP address of the BSC. When the BSC provides the function of simple cell broadcast, the BSC sends cell broadcast messages through this IP address defined by this parameter. GBFD-113601Short Message Service Cell Broadcast (TS23) IP Address Type None 0.0.0.0~255.255.255.255 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BSCGATHET BSC Offset Collection End Time BSC6900 ADD AISSCFG(Optional) End time for collecting the inter-BSC offset information. GBFD-118201Soft-Synchronized Network Compound Type hour, min hour{0~23}min{0~59} None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None.
BSCGATHST BSC Offset Collection Start Time BSC6900 ADD AISSCFG(Optional) Start time for collecting the inter-BSC offset information. GBFD-118201Soft-Synchronized Network Compound Type hour, min hour{0~23}min{0~59} None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None.
BSCID BSC ID BSC6900 ADD ADJNODE(Mandatory) Unique ID of one BSC in the TC POOL scenario None None Interval Type 0~15 0~15 None None None Adjacent node None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BSCIDX BSC Index BSC6900 ADD GEXT2GCELL(Optional)ADD EXTBSC(Mandatory) ID of the BSC that controls the external 2G neighbor cell MRFD-210301Configuration Management Interval Type 0~15 0~15 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BSCINCHPRD BSC Fine Tuning Period BSC6900 ADD AISSCFG(Optional) Period for fine tuning the BTS clock between BSCs. GBFD-118201Soft-Synchronized Network Interval Type 5~60 5~60 d 5 None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None.
BSCIP BSC IP BSC6900 ADD GCBSADDR(Mandatory) IP address of the BSC. If the connection mode of the BSC and the CBC is to lead cables out of the PIU, the value of this parameter must be the same as the preset IP address of the PIU port.If the connection mode is to lead cables out of the XPU panel, the value of this parameter must be the same as the preset IP address of the XPU panel. GBFD-113601Short Message Service Cell Broadcast (TS23) IP Address Type None 0.0.0.0~255.255.255.255 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BSCIP BSC IP BSC6900 ADD BTSAUTOPLAN(Mandatory)SET BTSIP(Optional) IP address of the interface board on the BSC. GBFD-118601Abis over IP IP Address Type None 0.0.0.0~255.255.255.255 None None None BTS The IP address must have been configured. Read & Write Y BTS Less than 5 minutes None
BscLsStartMode Options for BSC Local Switch BSC6900 SET BSSLS(Optional) Conditions for enabling the function of BSC local switching.UNCONDITIONALSTART: The function of BSC local switching is enabled without restriction.ATERCONGESTS: The function of BSC local switching is enabled when the congestion rate of the Ater interface exceeds the value of "Ater Cong Thres for BSC LocalSwitch".PREFIXNUMBER: The function of BSC local switching is enabled when the leading digits of the calling or called MSISDN are the preset value of "Prefix Number for BSC (1-10)". GBFD-117701BSC Local Switch Enumeration Type UNCONDITIONALSTART(Unconditional Start), ATERCONGESTS(Start When Ater Congests), PREFIXNUMBER(Start by Prefix Number) UNCONDITIONALSTART, ATERCONGESTS, PREFIXNUMBER None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BSCNAME External BSC Name BSC6900 ADD EXTBSC(Mandatory) Unique name of the external BSC GBFD-118621Connection Inter BSC over IP String Type None 1~64 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BSCPN In-BSC Port No. BSC6900 ADD BTSMONITORTS(Mandatory) In-BSC port No. of the monitoring timeslot GBFD-114701Semi-Permanent Connection Interval Type 0~335 0~335 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BSCPORT BSC Port BSC6900 ADD GCBSADDR(Mandatory) Port number used for the communication between the BSC and the CBC GBFD-113801TRX Cooperation Interval Type 0~65535 0~65535 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BSCRESERVEDPARA1 Reserved parameter 1 BSC6900 SET OTHSOFTPARA(Optional) Reserved parameter 1 that is effective at the BSC level MRFD-210301Configuration Management Interval Type 0~65535 0~65535 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BSCRESERVEDPARA10 Reserved parameter 10 BSC6900 SET OTHSOFTPARA(Optional) Reserved parameter 10 that is effective at the BSC level MRFD-210301Configuration Management Interval Type 0~65535 0~65535 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BSCRESERVEDPARA11 Reserved parameter 11 BSC6900 SET OTHSOFTPARA(Optional) Reserved parameter 11 that is effective at the BSC level MRFD-210301Configuration Management Interval Type 0~65535 0~65535 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BSCRESERVEDPARA12 Reserved parameter 12 BSC6900 SET OTHSOFTPARA(Optional) Reserved parameter 12 that is effective at the BSC level MRFD-210301Configuration Management Interval Type 0~65535 0~65535 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BSCRESERVEDPARA13 Reserved parameter 13 BSC6900 SET OTHSOFTPARA(Optional) Reserved parameter 13 that is effective at the BSC level MRFD-210301Configuration Management Interval Type 0~65535 0~65535 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BSCRESERVEDPARA14 Reserved parameter 14 BSC6900 SET OTHSOFTPARA(Optional) Reserved parameter 14 that is effective at the BSC level MRFD-210301Configuration Management Interval Type 0~65535 0~65535 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BSCRESERVEDPARA15 Reserved parameter 15 BSC6900 SET OTHSOFTPARA(Optional) Reserved parameter 15 that is effective at the BSC level MRFD-210301Configuration Management Interval Type 0~65535 0~65535 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BSCRESERVEDPARA16 Reserved parameter 16 BSC6900 SET OTHSOFTPARA(Optional) Reserved parameter 16 that is effective at the BSC level MRFD-210301Configuration Management Interval Type 0~65535 0~65535 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BSCRESERVEDPARA17 Reserved parameter 17 BSC6900 SET OTHSOFTPARA(Optional) Reserved parameter 17 that is effective at the BSC level MRFD-210301Configuration Management Interval Type 0~65535 0~65535 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BSCRESERVEDPARA18 Reserved parameter 18 BSC6900 SET OTHSOFTPARA(Optional) Reserved parameter 18 that is effective at the BSC level MRFD-210301Configuration Management Interval Type 0~65535 0~65535 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BSCRESERVEDPARA19 Reserved parameter 19 BSC6900 SET OTHSOFTPARA(Optional) Reserved parameter 19 that is effective at the BSC level MRFD-210301Configuration Management Interval Type 0~65535 0~65535 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BSCRESERVEDPARA2 Reserved parameter 2 BSC6900 SET OTHSOFTPARA(Optional) Reserved parameter 2 that is effective at the BSC level MRFD-210301Configuration Management Interval Type 0~65535 0~65535 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BSCRESERVEDPARA3 Reserved parameter 3 BSC6900 SET OTHSOFTPARA(Optional) Reserved parameter 3 that is effective at the BSC level MRFD-210301Configuration Management Interval Type 0~65535 0~65535 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BSCRESERVEDPARA4 Reserved parameter 4 BSC6900 SET OTHSOFTPARA(Optional) Reserved parameter 4 that is effective at the BSC level MRFD-210301Configuration Management Interval Type 0~65535 0~65535 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BSCRESERVEDPARA5 Reserved parameter 5 BSC6900 SET OTHSOFTPARA(Optional) Reserved parameter 5 that is effective at the BSC level MRFD-210301Configuration Management Interval Type 0~65535 0~65535 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BSCRESERVEDPARA6 Reserved parameter 6 BSC6900 SET OTHSOFTPARA(Optional) Reserved parameter 6 that is effective at the BSC level MRFD-210301Configuration Management Interval Type 0~65535 0~65535 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BSCRESERVEDPARA7 Reserved parameter 7 BSC6900 SET OTHSOFTPARA(Optional) Reserved parameter 7 that is effective at the BSC level MRFD-210301Configuration Management Interval Type 0~65535 0~65535 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BSCRESERVEDPARA8 Reserved parameter 8 BSC6900 SET OTHSOFTPARA(Optional) Reserved parameter 8 that is effective at the BSC level MRFD-210301Configuration Management Interval Type 0~65535 0~65535 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BSCRESERVEDPARA9 Reserved parameter 9 BSC6900 SET OTHSOFTPARA(Optional) Reserved parameter 9 that is effective at the BSC level MRFD-210301Configuration Management Interval Type 0~65535 0~65535 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BSCSN In-BSC Slot No. BSC6900 ADD BTSMONITORTS(Mandatory) In-BSC slot No. of the monitoring timeslot GBFD-114701Semi-Permanent Connection Interval Type 0~27 0~27 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BSCSRN In-BSC Subrack No. BSC6900 ADD BTSMONITORTS(Mandatory) In-BSC subrack No. of the monitoring timeslot GBFD-114701Semi-Permanent Connection Interval Type 0~11 0~11 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BSCSUBTS In-BSC Sub Timeslot No. BSC6900 ADD BTSMONITORTS(Mandatory) In-BSC sub-timeslot No. of the monitoring timeslot. If the added monitoring timeslot works at 64 kbit/s, the sub-timeslots are numbered from 0. If the added monitoring timeslot works at 32 kbit/s, the sub-timeslots are numbered from 0 or 4. If the added monitoring timeslot works at 16 kbit/s, the sub-timeslots are numbered from 0, 2, 4, or 6. If the added monitoring timeslot works at 8 kbit/s, the sub-timeslots are numbered from any value among 0 to 7. GBFD-114701Semi-Permanent Connection Interval Type 0~7 0~7 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BSCSYMOFF BSC Symbol Offset BSC6900 SET BSCAISS(Mandatory) When the BTS clock is adjusted, the offset is added to obtain better network performance. GBFD-118201Soft-Synchronized Network Interval Type 0~2500 0~2500 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None.
BSCTID ID of BSC in TC Pool BSC6900 ADD ATERE1T1(Mandatory)ADD ATERSL(Mandatory)ADD SEMILINK(Mandatory) BSC ID in the TC pool. GBFD-113726TC Pool Interval Type 0~15 0~15 None None None E1/T1 linkWhen configure TC data, for example, select TC for "BM/TC config Flag", or MTP2 for "Application Type", the parameter should be set. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BSCTID ID of slave BSC in TC Pool BSC6900 SET BSCBASIC(Mandatory) ID of the BSC that supports the TC pool function. GBFD-113726TC Pool Interval Type 1~15 1~15 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BSCTS In-BSC Timeslot No. BSC6900 ADD BTSMONITORTS(Mandatory) In-BSC timeslot No. of the monitoring timeslot GBFD-114701Semi-Permanent Connection Interval Type 1~31 1~31 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BSCVMAX BS_CV_MAX BSC6900 SET GCELLPSBASE(Optional) This parameter is used to set the parameter BS_CV_MAX for MS countdown. This parameter is used for the MS to calculate the CV. This parameter also determines the duration of the timer T3198. When the MS sends one uplink RLC data block, the receiving state of this data block is set to Pending and the timer T3198 is started. If the MS receives the packet uplink acknowledge before the timer T3198 expires, the MS updates the receiving state of each uplink RLC data block according to the bit map in the message. If the timer T3198 of the RLC data block in the Pending state expires, the MS sets the receiving state of this data block to Nack and retransmits the data bloc. GBFD-114101GPRS Interval Type 0~15 0~15 None None 10 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BSMSPWRLEV Transfer BS/MS Power Clas BSC6900 SET GCELLHOCTRL(Optional) Whether to enable the BTS to transfer BS/MS power class to the BSC GBFD-110802Pre-processing of Measurement Report Enumeration Type NO(No), YES(Yes)NO, YES None None YES Cell This parameter must be set when "BTSMESRPTPREPROC" is set to BTS_PreprocessingN. Read & Write N (No impact on the UE in idle mode) Not involved Not involved If "MR.Preprocessing" is set to BTS_Preprocessing and this parameter is set to NO, the uplink-downlink balance associated traffic statistics is improper. In addition, the handover algorithms that require power compensation are improper, such as PBGT handover, load handover, and concentric cell handover.
BSPAGBLKSRES Number of PAGCH Blocks BSC6900 ADD GCELL(Optional) Number of PAGCH blocks MRFD-210301Configuration Management Interval Type 0~12 0~12 None 4 4 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BSPAMFRAMS Multi-Frames in a Cycle on the Paging CH BSC6900 SET GCELLIDLEBASIC(Optional) Number of multiframes in a cycle on a paging sub-channel. In fact, this parameter specifies the number of paging sub-channels that a paging channel in a cell is divided into.In an actual network, an MS does not listen to other paging sub-channels but its belonging paging sub-channel only. Refer to GSM Rec. 05.02 and GSM Rec. 05.08. The larger the value of this parameter, the more the number of the paging sub-channels in a cell, and the fewer the number of the users belonging to each paging sub-channel. In this case, the mean uptime of the MS battery can be prolonged. Refer to the computing mode of paging group in GSM 05.02 of GSM Standards. The larger the value of this parameter, however, the larger the time delay of a paging message in a space segment. Thus, the average service performance of the system lowers. Based on the principle of ensuring that overload does not occur to paging channels, you must set this parameter to a value as small as possible. You must regularly measure the overload conditions of GBFD-110303Paging Enumeration Type 2_M_PERIOD(2 Multiframe Period), 3_M_PERIOD(3 Multiframe Period), 4_M_PERIOD(4 Multiframe Period), 5_M_PERIOD(5 Multiframe Period), 6_M_PERIOD(6 Multiframe Period), 7_M_PERIOD(7 Multiframe Period), 8_M_PERIOD(8 Multiframe Period), 9_M_PERIOD(9 Multiframe Period) 2_M_PERIOD, 3_M_PERIOD, 4_M_PERIOD, 5_M_PERIOD, 6_M_PERIOD, 7_M_PERIOD, 8_M_PERIOD, 9_M_PERIOD, step: multiframe period ms None 2_M_PERIOD Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved A paging block (four continuous CCCH timeslots) can bear two IMSI paging messages, four TMSI paging messages, or two AGCH immediate assignment message. If the signaling downlink is faulty when an MS is idle, the rule of downlink failure is based on the signaling downlink failure counter DSC. When an MS stays in a cell, the DSC is initialized as an integer the closest to 90/N ("N" is BS_PA_MFRMS, number of multiframes in a cycle on a paging sub-channel, whose value range is 2 to 9.) When the MS tries to encode the messages over its paging sub-channels: Every time the MS succeeds in encoding a message, the DSC increases by 1 but cannot exceed the initially set value; if the MS fails in encoding a message, the DSC decreases by 4. If the DSC is smaller than or equal to 0, a signaling downlink failure occurs, which causes cell reselection. The value of this parameter varies with the BTS types.
BSPBCCHBLKS Number of PBCCH Blocks BSC6900 ADD GCELL(Optional) Number of PBCCH blocks MRFD-210301Configuration Management Interval Type 1~4 1~4 None 1 1 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BSPRACHBLKS Number of PRACH Blocks BSC6900 ADD GCELL(Optional) Number of PRACH blocks MRFD-210301Configuration Management Interval Type 0~12 0~12 None 1 1 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BssLsGenMode BSS Local Switching General Strategy BSC6900 SET BSSLS(Optional) General strategy of the BSS local switching, which includes the BSC local switching and the BTS local switching. The two functions cannot be enabled at the same time. GBFD-117701GBFD-117702 BSC Local SwitchBTS Local Switch Enumeration Type NEITHERSTART(Neither Start), BTSPRIORITY(BTS Priority), BSCPRIORITY(BSC Priority), BTSONLY(BTS Only), BSCONLY(BSC Only) NEITHERSTART, BTSPRIORITY, BSCPRIORITY, BTSONLY, BSCONLY None None NEITHERSTART BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BSSLSMSCCOOP MSC-Collaborated BSS Local Switching BSC6900 ADD GCNNODE(Optional) Type of the BSS local switching with the cooperation of the MSC.NONSUPPORT: When performing local switching, the BSS need not determine whether the MSC allows an MS to be involved in local switching.BASIC: Assignment request messages and handover request messages sent by the MSC contain a flag indicating whether to allow an MS for local switching. The BSS must identify this flag when performing local switching.ENHANCED: Assignment request messages and handover request messages sent by the MSC contain a flag indicating whether to allow an MS for local switching. The BSS must identify this flag when performing local switching. In addition, when the BSS enables or stops local switching, the BSS sends a local switching enabled or stopped message to the MSC. GBFD-117701GBFD-117702 BSC Local SwitchBTS Local Switch Enumeration Type NONSUPPORT(Not Support), BASIC(Basic Fun), ENHANCED(Enhanced Fun) NONSUPPORT, BASIC, ENHANCED None NONSUPPORTNONSUPPORT MSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BSSPAGINGCOORDINATION BSS Paging Co-ordination BSC6900 SET GCELLPSBASE(Optional) Whether to support the paging function of the CS domain of the A interface. Yes: the MS can be called upon paging request on the A interface when the MS uses the GPRS; No: the MS cannot be called upon paging request on the A interface when the MS uses the GPRS. This parameter is valid only when the paging switch is turned on at the A interface of the BSS software parameter. GBFD-119305BSS Paging Coordination Enumeration Type NO(NO), YES(YES) NO, YES None None YES Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter is valid on a per cell basis and is valid only when "ACOOPERATPAGINGSWITCH" in the "SET BSCPSSOFTPARA" command is set to YES.
BT Board type BSC6900 LOD PATCH(Mandatory) Type of the board MRFD-210401BSC/RNC Software Management Enumeration Type SCUa, GCUa, GCGa, PEUa, AEUa, FG2a, GOUa, AOUa, POUa, UOIa, EIUa, OIUa, AOUc, POUc, UOIc, FG2c, GOUc, SPUa, XPUa, SPUb, XPUb, DPUa, DPUb, DPUc, DPUd, DPUe, TNUa, ALL SCUa, GCUa, GCGa, PEUa, AEUa, FG2a, GOUa, AOUa, POUa, UOIa, EIUa, OIUa, AOUc, POUc, UOIc, FG2c, GOUc, SPUa, XPUa, SPUb, XPUb, DPUa, DPUb, DPUc, DPUd, DPUe, TNUa, ALL None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BT Board type BSC6900 CON PATCH(Mandatory) Type of the board MRFD-210401BSC/RNC Software Management Enumeration Type SCUa, GCUa, GCGa, PEUa, AEUa, FG2a, GOUa, AOUa, POUa, UOIa, EIUa, OIUa, AOUc, POUc, UOIc, FG2c, GOUc, SPUa, XPUa, SPUb, XPUb, DPUa, DPUb, DPUc, DPUd, DPUe, TNUa SCUa, GCUa, GCGa, PEUa, AEUa, FG2a, GOUa, AOUa, POUa, UOIa, EIUa, OIUa, AOUc, POUc, UOIc, FG2c, GOUc, SPUa, XPUa, SPUb, XPUb, DPUa, DPUb, DPUc, DPUd, DPUe, TNUa None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BT Board type BSC6900 SET CLK(Mandatory) Type of the board MRFD-210502BSC/RNC Clock Enumeration Type AEUa, PEUa, AOUa, POUa, UOIa, EIUa, OIUa, AOUc, POUc, UOIc AEUa, PEUa, AOUa, POUa, UOIa, EIUa, OIUa, AOUc, POUc, UOIc None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BT Board type BSC6900 SET E1T1LOP(Mandatory) Board type None None Enumeration Type AEUa, AOUa, PEUa, POUa, AOUc, POUc, EIUa, OIUa AEUa, AOUa, PEUa, POUa, AOUc, POUc, EIUa, OIUa None None None E1/T1 port None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
BT Board type BSC6900 LOP E1T1(Mandatory) Board type None None Enumeration Type AEUa, AOUa, PEUa, POUa, AOUc, POUc, EIUa AEUa, AOUa, PEUa, POUa, AOUc, POUc, EIUa None None None Cell None Read & Write Y Cell Less than 5 minutes None
BT Board type BSC6900 STR E1T1TST(Mandatory) Board type None None Enumeration Type AEUa, AOUa, AOUc, PEUa, POUa, POUc, EIUa, OIUa AEUa, AOUa, AOUc, PEUa, POUa, POUc, EIUa, OIUa None None None E1/T1 port None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
BT Board type BSC6900 SET E1T1(Mandatory) Board type None None Enumeration Type AEUa, AOUa, AOUc, PEUa, POUa, POUc, EIUa, OIUa AEUa, AOUa, AOUc, PEUa, POUa, POUc, EIUaA/EIUaB/EIUaP/EIUaT, OIUaA/OIUaB/OIUaP/OIUaT None None None E1/T1 port None Read & Write N (No impact on the UE in idle mode) Not involved Not involved If certain link is occupied, conversion from E1 to T1 or from T1 to E1 cannot be performed.
BT Board type BSC6900 SET OPT(Mandatory) Board type None None Enumeration Type AOUa, POUa, UOIa, AOUc, UOIc, POUc, OIUa AOUa, POUa, UOIa, AOUc, UOIc, POUc, OIUa None None None Board None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
BT Board Type BSC6900 SET COPTLNK(Mandatory) Board type None None Enumeration Type AOUa, POUa, AOUc, POUc, OIUa AOUa, POUa, AOUc, POUc, OIUa None None None Channelized optical port None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
BT Board type BSC6900 ADD IPLOGICPORT(Mandatory) Board type None None Enumeration Type FG2a, GOUa, UOIa, FG2c, GOUc, POUc FG2a, GOUa, UOIa, FG2c, GOUc, POUc None None None IP logical port None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BT Board type BSC6900 CHK E1T1CRS(Mandatory) Board type None None Enumeration Type EIUa EIUa None None None E1/T1 port None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
BT Board Type. BSC6900 ADD BTSRETANT(Mandatory) Type of the board that controls the RET antenna. 1. DATU: It may represent the DATU or the DATM and is applicable to the BTS3012, BTS3012AE, BTS3012_II, BTS3006C, and BTS3002E.2. GATM: It is applicable to the BTS3900 GSM, BTS3900A GSM, BTS3036, and BTS3036A. MRFD-210602Remote Electrical Tilt Enumeration Type DATU(DATU), GATM(GATM), DRRU(DRRU), MRRU(MRRU), MRFU(MRFU), GRFU(GRFU), GRRU(GRRU) DATU, GATM, DRRU, MRRU, MRFU, GRFU, GRRU None None None BTS None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
BT Board Type BSC6900 ADD BTSANTFEEDERBRD(Mandatory) Type of the newly added antenna board GBFD-111202O&M of BTS Enumeration Type CDU(CDU), PCDU(PCDU), DCDU(DCDU), CDUC(CDUC), CDUP(CDUP), RCDU(RCDU), CDUR(CDUR), CDUE(CDUE), EDU(EDU), PEDU(PEDU), REDU(REDU), DEDU(DEDU), EDUC(EDUC), EDUP(EDUP), EDUR(EDUR), EDUE(EDUE), DDPM_DDPU(DDPM_DDPU), DFCU(DFCU), DFCB(DFCB) CDU, PCDU, DCDU, CDUC, CDUP, RCDU, CDUR, CDUE, EDU, PEDU, REDU, DEDU, EDUC, EDUP, EDUR, EDUE, DDPM_DDPU, DFCU, DFCB None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BT Board Type BSC6900 ADD BTSBRD(Mandatory) Type of the newly added board GBFD-111202O&M of BTS Enumeration Type PWC(PWC), EAC_EMUA(EAC_EMUA), DTMU(DTMU), DATM_DATU(DATM_DATU), NFCB(NFCB), EMU_DEMU(EMU_DEMU), DPMU(DPMU), DCBM_DCOM(DCBM_DCOM), DHEU(DHEU), ECOM(ECOM), MFU(MFU), MPW(MPW), MCD(MCD), IASU(IASU), PTU(PTU), TMU(TMU), PSU_APSU(PSU_APSU), PMU_APMU(PMU_APMU), 3001C_MFU(3001C_MFU), TEU(TEU), TES(TES), PBU(PBU), DPBU(DPBU), RPBU(RPBU), PPBU(PPBU), SCU(SCU), MDU(MDU), UPEU(UPEU), UEIU(UEIU), FMU(FMU), FMUA(FMUA), DTCU(DTCU), GATM(GATM), DGPS(DGPS), USCU(USCU), UBRI(UBRI), FAN(FAN), EMU(EMU), PMU(PMU), TCU(TCU), PSU(PSU) BIE, PWC, EAC, EMUA, MCK, DTMU, DATM_DATU, NFCB, EMU_DEMU, DPMU, DCBM_DCOM, DHEU, ECOM, MFU, MPW, MCD, IASU, PTU, TMU, PSU, PMU, APMU, 3001C_MFU, TEU, TES, PBU, DPBU, RPBU, PPBU, SCU, MDU, UPEU, UEIU, FMU, FMUA, DTCU, GATM, DGPS, USCU, UBRI, FAN, EMU, PMU, TCU, PSU None None None BTS The value range of this parameter varies with BTS type. Different types of BTSs support different type of boards. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BT Board Type BSC6900 ADD BTSRXUBRD(Mandatory) Type of the newly added RXU board GBFD-111202O&M of BTS Enumeration Type DRRU(DRRU), DRFU(DRFU), MRRU(MRRU), XRRU(XRRU), MRFU(MRFU), GRFU(GRFU), GRRU(GRRU), XRFU(XRFU), BTS3900E(BTS3900E) DRRU, DRFU, MRRU, XRRU, MRFU, GRFU, GRRU, XRFU, BTS3900E None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BT Board Type BSC6900 ADD BTSTRXBRD(Mandatory) Type of the board GBFD-111202O&M of BTS Enumeration Type TRX(TRX_DEFAULT), TRX_GPRS(TRX_GPRS), DRU(TRX_30), PTRX(PTRX), ETRX(ETRX), RTRX(RTRX), DTRX(DTRX), RETR(RETR), DETR(DETR), EETR(EETR), PETR(PETR), MTR(MTR), TRU(TRU/DTRU), QTRU(QTRU) TRX_30_OR_DRU, TRX_GPRS, PTRX, ETRX, RTRX, DTRX, RETR, DETR, EETR, PETR, MTR, TRU, QTRU None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BT Board Type BSC6900 SET BTSANTFEEDERCONNECT(Mandatory) Type of the board GBFD-111202O&M of BTS Enumeration Type CDU(CDU), CDUC(CDUC), CDUP(CDUP), CDUR(CDUR), CDUE(CDUE), PCDU(PCDU), RCDU(RCDU), DCDU(DCDU), EDU(EDU), EDUC(EDUC), EDUP(EDUP), EDUR(EDUR), EDUE(EDUE), PEDU(PEDU), REDU(REDU), DEDU(DEDU), DDPM_DDPU(DDPM_DDPU), DFCU(DFCU), DFCB(DFCB) CDU, CDUC, CDUP, CDUR, CDUE, PCDU, RCDU, DCDU, EDU, EDUC, EDUP, EDUR, EDUE, PEDU, REDU, DEDU, DDPM_DDPU, DFCU, DFCB None None None BTS None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
BTCFLAG BM/TC config flag BSC6900 ADD ATERE1T1(Mandatory) The configuration flag specifies the operation is on the BM or TC. GBFD-111801Ater Interface 4:1 Multiplexing Enumeration Type CFGBM(BM), CFGTC(TC) CFGBM, CFGTC None None None E1/T1 linkNone Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BTCFLAG BM/TC config flag BSC6900 ADD ATERSL(Mandatory) CFGBM indicates that the BM signaling link is from BSC in the configuration.CFGGTC indicates that the TC signaling link is from BSC in the configuration. GBFD-111801Ater Interface 4:1 Multiplexing Enumeration Type CFGBM(BM), CFGTC(TC) CFGBM, CFGTC None None None ATERCONSL None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
BTSadjust Adjust Voltage BSC6900 SET GCELLBASICPARA(Optional) Working voltage used by the power amplifier. The BSC supports that the power amplifier uses different working voltages in different TRX modulation modes. GBFD-111202O&M of BTS Enumeration Type NO(No), YES(Yes)NO, YES None None YES Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BTSCOMTYPE BTS Com Type BSC6900 SET BTSIP(Optional) Communication type of a BTS GBFD-118601Abis over IP Enumeration Type LOGICIP(Logic IP), PORTIP(Port IP), PPP/MP(PPP/MP) LOGICIP, PORTIP, PPP/MP None None None BTS None Read & Write Y BTS Less than 5 minutes None
BTSDESC BTS Description BSC6900 ADD BTS(Optional) Peer equipment type of the BTS. This parameter indicates whether to connect the BTS to the BSC or cascade the BTS to another BTS. GBFD-111202O&M of BTS String Type None 0~64 characters None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter cannot contain #.
BTSDETECTSWITCH BTS Detect Switch BSC6900 SET BTSOTHPARA(Optional) BTS detection switch. If the parameter is set to "CLOSE", the function of detecting the BTS is disabled. If the parameter is set to "OPEN", the function of detecting the BTS is enabled. When the function of detecting the BTS is enabled, the BSC performs addressing according to the BTS IP address and sends the UDP packet carrying the VLANID to the BTS. GBFD-118601Abis over IP Enumeration Type CLOSE(CLOSE), OPEN(OPEN) CLOSE, OPEN None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BTSID Site Index BSC6900 ADD ADJNODE(Mandatory) BTS index of the adjacent node to be added. The parameter is valid when Adjacent node type is set to Abis. None None Interval Type 0~2047 0~2047 None None None Adjacent node None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BTSID BTS Index BSC6900 SET BTSEXCURSION(Mandatory)SET BSCSYNCOFF(Mandatory)SET BTSAISS(Mandatory)ADD BTSESN(Mandatory)SET GMRSCOPE(Mandatory)SWP BTSRING(Mandatory)ADD CELLBIND2BTS(Mandatory)SET BTSAIRCON(Mandatory)SET BTSALM(Mandatory)SET BTSAUXEQP(Mandatory)SET BTSBAKPWR(Mandatory)SET BTSBAT(Mandatory)SET BTSCHNFALLBACK(Mandatory)SET BTSCRC4(Mandatory)SET BTSLOCKBCCH(Mandatory)SET BTSLSW(Mandatory)SET BTSTRANS(Mandatory)SET BTSVLAN(Mandatory)SWP BTSOMLLINK(Mandatory)ADD BTS(Mandatory)ADD BTSBFD(Mandatory)SET BTSTHEFTALM(Mandatory)SET BTSSPTMODE(Mandatory)SET BTSOUTPUT(Mandatory)SET BTSOMLBACKUP(Mandatory)SET BTSFALLBACK(Mandatory)SET BTSEXD(Mandatory)SET BTSCLK(Mandatory)SET BTSABISTROP(Mandatory)SET BTSFMUABP(Mandatory)SET BTSNFCBBP(Mandatory)SET BTSPMUBP(Mandatory)SET BTSAPMUBP(Mandatory)SET BTSDATUBP(Mandatory)SET BTSDEMUBP(Mandatory)SET BTSDFCUBP(Mandatory)SET BTSDHEUBP(Mandatory)SET BTSDOMUBP(Mandatory)SET BTSDPMUBP(Mandatory)SET BTSDTMUBP(Mandatory)SET BTSDGPSBP(Mandatory)SET BTSPSUFP ID of the BTS. The BTS ID must not conflict with other BTS IDs in the BSC. GBFD-111202O&M of BTS Interval Type 0~2047 0~2047 None None None BTS None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
BTSID BTS Index BSC6900 SET BTSABISPRIMAP(Mandatory) Index of the BTS running the command GBFD-111202O&M of BTS Interval Type 0~2047 0~2047 None None None BSC6900None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
BTSIDCONBSC Connect BSC BTS Index BSC6900 ADD BTSABISHDLCPATH(Mandatory) Number of the BTS connected to the BSC. The number is unique in a BSC GBFD-118401Abis Transmission Optimization Interval Type 0~2047 0~2047 None None None BTS None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
BTSIDLST BTS Index List BSC6900 LOD BTSSW(Mandatory)LOD BTSPATCH(Mandatory)CON BTSPATCH(Mandatory) List of BTS indexes. You can specify multiple BTSs by &. GBFD-111202O&M of BTS Interval Type 0~2047 0~2047 None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BTSIDTYPE BTS Index Type BSC6900 COL SYNCINFO(Mandatory) Whether to collect offset information by BTS index or BTS name. GBFD-118201Soft-Synchronized Network Enumeration Type BYIDX(By BTS Index), BYNAME(By BTS Name) BYIDX, BYNAME None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None.
BTSIDTYPE BTS Index Type BSC6900 SET BTSANTANGLE(Mandatory) Index type of the BTS. BYNAME: query by BTS name; BYID: query by BTS index. MRFD-210602Remote Electrical Tilt Enumeration Type BYNAME(By Name), BYID(By Index) BYNAME, BYID None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BTSIDX Site Index Collect BSC6900 ADD BTSOP(Mandatory) Base station index, 65535 indicate all base stations. MRFD-210305Security Management Interval Type 0~2047,65535 {0~2047}, {65535} None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BTSIP BTS IP BSC6900 ADD BTSAUTOPLAN(Mandatory)SET BTSIP(Optional) IP address of a BTS. When "BTS Com Type" is set to "LOGICIP", the value of the parameter is the IP address of the BTS. When "BTS Com Type" is set to "PORTIP", the value of the parameter is the IP address of the BTS ethernet port. When "BTS Com Type" is set to "PPPLNK" or "MPGRP", the value of the parameter is the local IP address of the BTS PPP link or BTS MLPPP group. GBFD-118601Abis over IP IP Address Type None 0.0.0.0~255.255.255.255 None None None BTS None Read & Write Y BTS Less than 5 minutes None
BtsLsStartMode Options for BTS Local Switch BSC6900 SET BSSLS(Optional) Conditions for enabling the function of BTS local switching.UNCONDITIONALSTART: The function of BTS local switching is enabled without restriction.ABISCONGESTS: The function of BTS local switching is enabled when the congestion rate of the Abis interface exceeds the value of "Abis Cong Thres for BTS LocalSwitch".PREFIXNUMBER: The function of BTS local switching is enabled when the leading digits of the calling or called MSISDN are the preset value of "Prefix Number for BTS (1-10)". GBFD-117702BTS Local Switch Enumeration Type UNCONDITIONALSTART(Unconditional Start), ABISCONGESTS(Start When Abis Congests), PREFIXNUMBER(Start by Prefix Number) UNCONDITIONALSTART, ABISCONGESTS, PREFIXNUMBER None None UNCONDITIONALSTART BSC6900The value of BtsLsStartMode should be set when "BssLsGenMode" is set to BTSPRIORITY, BSCPRIORITY, or BTSONLY. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BTSMASK Subnet mask BSC6900 ADD BTSAUTOPLAN(Mandatory) Mask of the subnet GBFD-118601Abis over IP IP Address Type None 0.0.0.0~255.255.255.255 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BTSMESRPTPREPROC MR.Preprocessing BSC6900 SET GCELLHOCTRL(Optional) Whether to enable the BTS to preprocess measurement reports. This parameter determines where to conduct power control. GBFD-110802Pre-processing of Measurement Report Enumeration Type BSC_Preprocessing(BSC preprocessing), BTS_Preprocessing(BTS preprocessing) BSC_Preprocessing, BTS_Preprocessing None None None Cell If the value of this parameter is BSC_Preprocessing, the pre-processing is performed on the BSC. In this case, the following parameters are invalid: "PRIMMESPPT", "BSMSPWRLEV", and "MRPREPROCFREQ". Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter can be set to BTS_Preprocessing only when the BTS supports the configured power control algorithm.
BTSNAME BTS Name BSC6900 SET BTSEXCURSION(Mandatory)SET BSCSYNCOFF(Mandatory)SET BTSAISS(Mandatory)SET BTSABISPRIMAP(Mandatory)ADD BTSESN(Mandatory)SWP BTSRING(Mandatory)ADD CELLBIND2BTS(Mandatory)SET BTSAIRCON(Mandatory)SET BTSALM(Mandatory)SET BTSAUXEQP(Mandatory)SET BTSBAKPWR(Mandatory)SET BTSBAT(Mandatory)SET BTSCHNFALLBACK(Mandatory)SET BTSCRC4(Mandatory)SET BTSLOCKBCCH(Mandatory)SET BTSLSW(Mandatory)SET BTSTRANS(Mandatory)SET BTSVLAN(Mandatory)SWP BTSOMLLINK(Mandatory)ADD BTS(Mandatory)ADD BTSBFD(Mandatory)SET BTSTHEFTALM(Mandatory)SET BTSSPTMODE(Mandatory)SET BTSOUTPUT(Mandatory)SET BTSOMLBACKUP(Mandatory)SET BTSFALLBACK(Mandatory)SET BTSEXD(Mandatory)SET BTSCLK(Mandatory)SET BTSABISTROP(Mandatory)SET BTSFMUABP(Mandatory)SET BTSNFCBBP(Mandatory)SET BTSPMUBP(Mandatory)SET BTSAPMUBP(Mandatory)SET BTSDATUBP(Mandatory)SET BTSDEMUBP(Mandatory)SET BTSDFCUBP(Mandatory)SET BTSDHEUBP(Mandatory)SET BTSDOMUBP(Mandatory)SET BTSDPMUBP(Mandatory)SET BTSDTMUBP(Mandatory)SET BTSDGPSBP(Mandatory)SET BTS Name of the BTS. The BTS name must not conflict with other BTS names in the BSC. GBFD-111202O&M of BTS String Type None 1~64 characters None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BTSNAMECONBSC Connect BSC BTS Name BSC6900 ADD BTSABISHDLCPATH(Mandatory) Connect BSC BTS Name.It is unique in one BSC.This parameter cannot contain ? | : < > " @# ! % ^ & * . [ ] / \ \\ '. GBFD-118401Abis Transmission Optimization String Type None 1~64 characters None None None BTS None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
BTSNAMELST BTS Name List BSC6900 LOD BTSSW(Mandatory)LOD BTSPATCH(Mandatory)CON BTSPATCH(Mandatory) List of BTS names. You can specify multiple BTSs by &. GBFD-111202O&M of BTS String Type None 1~2048 characters None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BTSPINGSWITCH BTS Ping Switch BSC6900 SET BTSPINGSW(Optional) If the parameter is set to "ON", allow all the Ping packets are sent. If the parameter is set to "OFF", all the Ping packets are discarded. GBFD-118601Abis over IP Enumeration Type OFF(Off), ON(On) OFF, ON None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter is required only by BTSs in IP transmission mode.
BTSPOWEROFFLOCKBCCH BTS Power-off Lock BCCH BSC6900 SET BTSLOCKBCCH(Mandatory) Whether to shut down the TRX that carries the main BCCH to save power when the BTS switches from the mains to batteries. If this parameter is set to NO, when the BTS switches from the mains to batteries, only the TRXs that can be shut down are shut down, except the TRX that carries the main BCCH. If this parameter is set to YES, when the BTS switches from the mains to batteries, all the TRXs of the BTS are shut down, including the TRX that carries the main BCCH. GBFD-111605Active Backup Power Control Enumeration Type NO(No), YES(Yes)NO, YES None None NO BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BTSPWRNUM BTS PC Class BSC6900 SET GCELLPWR2(Optional) Maximum degree by which the BSC can control the power of the BTS dynamically GBFD-110703Enhanced Power Control Algorithm Interval Type 1~16 1~16, step:2 dB None 16 Cell This parameter is valid when "PWRCTRLSW" in the "SET GCELLPWRBASIC" command is set to PWR2. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BTSSAICPCADJSWITCH Switch for BTS Supporting SAIC PC Adjust BSC6900 SET GCELLSOFT(Optional) Whether the BTS allows sending "Power Control threshold Adjust for SAIC" in Huawei III "SET GCELLPWR3" GBFD-118103Network Support SAIC Enumeration Type OFF(Off), ON(On) OFF, ON None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved For a double-transceiver BTS or an NGBTS, the initial value is ON. For a BTS of any other type, the initial value is OFF and unconfigurable.
BTSSWVER BTS Software Version BSC6900 LOD BTSSW(Mandatory) Software version number of the BTS GBFD-111202O&M of BTS String Type None 1~256 characters None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BTSTRCMPRATE Transmission compression ratio BSC6900 SET BTSTRCMPR(Mandatory) Transmission compression ratio of a BTS. 1. Modifying the settings of "Transfers Compress Rate" may change the bandwidth required by the BTS. That is, the current bandwidth may be excessive or insufficient. If the bandwidth is insufficient, more secondary links should be added or timeslots should be rearranged. 2. The greater the "Transfers Compress Rate" is, the smaller the compression rate is and the greater the required bandwidth is. 3. The user can get the actual value through multiplying the value of this parameter by 0.01. The default value of this parameter is 100, which means no compression. GBFD-118401Abis Transmission Optimization Interval Type 1~250 1~250 None None None BTS This parameter is used to caculate BindWidth of BTSAbisHDLCPath:1. When Transmission compression ratio is within range of [1, 200], BindWidth=16K*(amount of TRXs) + 64K*(amount of TRXs)*(Transmission compression ratio)/100;2. When Transmission compression ratio is within range of [200, 250], BindWidth=16K*(amount of TRXs) + 64K*(amount of TRXs)*(200 + (Transmission compression ratio - 200)*12)/100. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BTSTYPE BTS Type BSC6900 SET BTSALM(Mandatory)ADD BTS(Mandatory) Type of the BTSGBFD-111202O&M of BTS Enumeration Type BTS30, BTS312, BTS3001C, BTS3001CP, BTS3002C, BTS3012A, BTS3006A, BTS3012, BTS3006C, BTS3002E, BTS3012AE, BTS3012_II, DBS3900_GSM, BTS3900_GSM, BTS3900A_GSM, DBS3036, BTS3036, BTS3036A, BTS3900B_GSM, BTS3900E_GSM, BTS3900L_GSM BTS30, BTS312, BTS3001C, BTS3001CP, BTS3002C, BTS3012A, BTS3006A, BTS3012, BTS3006C, BTS3002E, BTS3012AE, BTS3012_II, DBS3900_GSM, BTS3900_GSM, BTS3900A_GSM, DBS3036, BTS3036, BTS3036A, BTS3900B_GSM, BTS3900E_GSM, BTS3900L_GSM None None None BTS None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
BTSTYPE BTS Type BSC6900 ADD BTSAUTOPLAN(Mandatory)SET BTSAUTOPLANCFG(Mandatory) Type of the BTSGBFD-510701Compact BTS Automatic Configuration and Planning Enumeration Type BTS3900B_GSM(BTS3900B GSM), BTS3900E_GSM(BTS3900E GSM) BTS3900B_GSM, BTS3900E_GSM None None None BTS None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
BTSTYPE BTS Type BSC6900 LOD BTSPATCH(Mandatory)CON BTSPATCH(Mandatory) Type of the BTSGBFD-111202O&M of BTS Enumeration Type BTS3012(BTS3012), BTS3006C(BTS3006C), BTS3002E(BTS3002E), BTS3012AE(BTS3012AE), BTS3012_II(BTS3012_II), DBS3900_GSM(DBS3900 GSM), BTS3900_GSM(BTS3900 GSM), BTS3900A_GSM(BTS3900A GSM), DBS3036(DBS3036), BTS3036(BTS3036), BTS3036A(BTS3036A), BTS3900L_GSM(BTS3900L GSM), BTS3900B_GSM(BTS3900B GSM), BTS3900E_GSM(BTS3900E GSM) BTS3012, BTS3006C, BTS3002E, BTS3012AE, BTS3012_II, DBS3900_GSM, BTS3900_GSM, BTS3900A_GSM, DBS3036, BTS3036, BTS3036A, BTS3900L_GSM, BTS3900B_GSM, BTS3900E_GSM None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BTSWTR Time for Waiting to Restore BSC6900 ADD BTSBFD(Optional) Time for which the BTS waits to restore a BFD session GBFD-118609IP Fault Detection Based on BFD Interval Type 0~1000000 0~1000000 s 3 3 Current BFD session None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BTTSTTYPE BT Test Type BSC6900 STR BTSTST(Mandatory) Type of TRX loopback test GBFD-111207BTS Test Function Enumeration Type BIULOOP(BIU Loopback Test), TRXSELFTEST(TRX Self Loopback Test) BIULOOP, TRXSELFTEST None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BTYPE Battery Type BSC6900 SET BTSAPMUBP(Optional) Battery type.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. GBFD-111202O&M of BTS Enumeration Type NO_BAT(No Storage Battery), LEADACID_BAT(Lead Acid Battery), LITHIUM_BAT(Lithium Battery) NO_BAT, LEADACID_BAT, LITHIUM_BAT None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BUILDTIME Ring II Try Rotating Duration Time BSC6900 SET BTSRINGATTR(Optional) If the OML is not established at one port after a period of time, the OML switches to another port and tries to connect to this port. That period of time is called ring II rotating duration time. GBFD-117802Fast Ring Network Switch Interval Type 10~255 10~255 s None None BTS The setting of this parameter must meet the following condition: "FallBack Start Time" > "Ring II Wait Time Before Switch" + "Ring II Try Rotating Duration Time". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BUNDLINGFLAG Bundling Flag BSC6900 ADD SCTPLNK(Optional) Whether to enable the data binding function. None None Enumeration Type NO(NO), YES(YES) YES, NO None NO NO None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BVCI PTP BVC Identifier BSC6900 ADD PTPBVC(Mandatory)BLK PTPBVC(Mandatory) Identifies a unique PTP BVC with NSE. GBFD-119001Gb Interface Function Interval Type 2~65534 2~65534 None None None Cell None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
BVCI PTPBVC identifier BSC6900 ADD GCELLQUICKSETUP(Optional) PTPBVC identifier GBFD-119001Gb Interface Function Interval Type 2~65534 2~65534 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BVCTF BVC Flow Control Timer BSC6900 SET BSSGPPARA(Optional) Duration of BVC flow control timer F. A cell sends the flow control message at the interval specified by this timer. GBFD-119001Gb Interface Function Interval Type 1000~3000 1000~3000 ms None 1000 BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BWADJ Auto adjust bandwidth switch BSC6900 ADD IPLOGICPORT(Mandatory) Switch for adjusting the dynamical bandwidth of the logical port If this switch is turned on, the system adjusts the dynamical bandwidth of the logical port according to the transmission quality of the link monitored by the IPPM. After this switch is turned on, the IPPM function must be activated on the IPPATH of this logical port. For details about the IPPM, see the description of the command "ACT IPPM". None None Enumeration Type OFF(OFF), ON(ON) OFF, ON None None None IP logical port The dynamic bandwidth switch is turned only when the IPPM function is activated through "ACT IPPM". Read & Write Not involved Not involved Not involved The parameter cannot be modified.
BWDCONGBW Backward congestion remain bandwidth BSC6900 ADD TRMLOADTH(Optional) Backward congestion remain bandwidth None None Interval Type 0~200000 0~200000 kbit/s 0 0 None None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
BWDCONGCLRBW Backward congestion clear bandwidth BSC6900 ADD TRMLOADTH(Optional) Backward congestion clear bandwidth None None Interval Type 0~200000 0~200000 kbit/s 0 0 None None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
BWDCONGCLRTH Backward congestion clear remain ratio BSC6900 ADD TRMLOADTH(Optional) Backward congestion clear remain ratio None None Interval Type 0~100 0~100 per cent 20 20 None None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
BWDCONGTH Backward congestion remain ratio BSC6900 ADD TRMLOADTH(Optional) Backward congestion remain ratio None None Interval Type 0~100 0~100 per cent 15 15 None None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
BWDOVLDCLRRSVBW Backward overload congestion clear remain bandwidth BSC6900 ADD TRMLOADTH(Optional) Backward overload congestion clear remain bandwidth None None Interval Type 0~200000 0~200000 kbit/s 0 0 None None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
BWDOVLDCLRTH Backward overload congestion clear remain ratio BSC6900 ADD TRMLOADTH(Optional) Backward overload congestion clear remain ratio None None Interval Type 0~100 0~100 per cent 1 1 None None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
BWDOVLDRSVBW Backward overload congestion reserved bandwidth BSC6900 ADD TRMLOADTH(Optional) Backward overload congestion reserved bandwidth None None Interval Type 0~200000 0~200000 kbit/s 0 0 None None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
BWDOVLDTH Backward overload congestion remain ratio BSC6900 ADD TRMLOADTH(Optional) Backward overload congestion remain ratio None None Interval Type 0~100 0~100 per cent 0 0 None None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
BWDRESVHOTH Backward handover reserved ratio BSC6900 ADD TRMLOADTH(Optional) Backward handover reserved ratio None None Interval Type 0~100 0~100 per cent 5 5 None None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
BWDRSVHOBW Backward handover reserved bandwidth BSC6900 ADD TRMLOADTH(Optional) Backward handover reserved bandwidth None None Interval Type 0~200000 0~200000 kbit/s 0 0 None None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
BWMAXRATIO Max bandwidth estimate ratio [%] BSC6900 ADD IPLOGICPORT(Optional) Maximum ratio of the estimated bottleneck bandwidth None None Interval Type 100~1000 100~1000 per cent 120 120 IP logical port None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BWMODE Bandwidth Mode BSC6900 ADD RSCGRP(Mandatory) Bandwidth mode. It is valid only when " Transport Resource Group Type " is set to IP. None None Enumeration Type FULL_DUPLEX(Full Duplex), HALF_DUPLEX(Half Duplex) FULL_DUPLEX, HALF_DUPLEX None None None Transmission resource group When "GRPT" in "ADD RSCGRP" is set to IP, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BWRTPTH Load Control algorithm BandWidth THD[%] BSC6900 ADD IPLOGICPORT(Optional) Threshold of bandwidth change based on the load control algorithm When the system detects that the change of the available bandwidth exceeds this threshold through the IPPM, the system starts adjusting the bandwidth of the logical port. None None Interval Type 0~100 0~100 per cent 25 25 IP logical port None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BWTHD Up Down Balance Alarm Threshold BSC6900 SET GTRXRLALM(Optional) Threshold for reporting the uplink-downlink imbalance alarm. If the percentage of the uplink-downlink imbalance measurement reports in the total valid measurement reports is equal to or greater than this threshold, the uplink-downlink imbalance alarm is reported. GBFD-110801GBFD-110802 Processing of Measurement ReportPre-processing of Measurement Report Interval Type 20~100 20~100 per cent None 80 TRX This parameter is valid only when "WLNKALMFLAG" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
BYCELLTYPE Cell Index Type BSC6900 ADD NCELL(Mandatory)COL SYNCINFO(Mandatory) Index type. The value can be BYIDX or BYNAME. MRFD-210301Configuration Management Enumeration Type BYIDX(By Cell Index), BYNAME(By Cell Name) BYIDX, BYNAME None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None.
C31HYST GPRS Cell Reselect Hysteresis Applied to C31 Criterion BSC6900 SET GCELLRESELECTPARA(Optional) Whether the reselection hysteresis parameter is applied to the C31 criterion. GBFD-114101GPRS Enumeration Type c31notuse(Not Use c31 standard), c31standard(Use c31 standard) c31notuse, c31standard None None c31standard Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
C32QUAL Exceptional Rule for GPRS Reselect Offset BSC6900 SET GCELLRESELECTPARA(Optional) Whether GPRS cell reselection offset is used for C32 calculation during cell reselection. If this parameter is set to 1, then only the positive hysteresis of the neighoring cell is used in C32 calculation. GBFD-114101GPRS Interval Type 0~1 0~1 None None 0 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CABINETDESC Cabinet Description BSC6900 ADD BTSCABINET(Optional) Descriptive information of the BTS cabinet GBFD-111202O&M of BTS String Type None 1~200 characters None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CABLST Cabinet List BSC6900 SET BTSRACKBC(Mandatory) List of all the cabinet numbers in the BTS GBFD-111202O&M of BTS Interval Type 0~8 0~8 None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CABT Is remote cabinet BSC6900 ADD CAB(Mandatory) Whether the added cabinet is a remote cabinet MRFD-210301Configuration Management Enumeration Type NO(NO), YES(YES) NO, YES None None None None None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
CALLRESTABDIS Call Reestablishment Forbidden BSC6900 SET GCELLBASICPARA(Optional) Whether to allow call reestablishment. If a call drop results from radio link failure caused by blind spots due to burst interferences or high buildings, an MS can start the process of call reestablishment to resume the conversation. GBFD-110503Call Reestablishment Enumeration Type NO(No), YES(Yes)NO, YES None None If this parameter is set to NO, the average call drop rate decreases. In suburbs or urban areas of poor coverage, the recommended value is NO. However, call reestablishment may take a long time; therefore, the subscriber may hang up the phone before the call is re-established. Generally, the recommended value is YES. Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CALVAL Calibration Value BSC6900 SET BTSCLKPARA(Mandatory) Calibration value of the clock GBFD-111202O&M of BTS Interval Type 0~4095 0~4095 None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CANPC PWRC BSC6900 SET GCELLCCCH(Optional) Whether an MS uses the calculated value as the final receive level value. The calculated receive level value is the measured receive level value minus the receive level value obtained from the BCCH TRX timeslots. This parameter is a cell option in system messages 3 and 6. GBFD-113701Frequency Hopping (RF hopping, baseband hopping) Enumeration Type NO(No), YES(Yes)NO, YES None None YES Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CAPCOVEROPTSWITCH Capacity and Coverage Optimize Switch BSC6900 SET BTSAUTOPLANCFG(Optional) Whether to enable the capacity and coverage of the BTS to be automatically optimized according to the actual situation of the incumbent network. GBFD-510702Compact BTS Automatic Capacity Planning Enumeration Type OFF(OFF), ON(ON) OFF, ON None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CARRYFLAG Carry Flag BSC6900 ADD IPPATH(Optional) Whether to indicate that the IP path is carried on the IP logic port or resource group None None Enumeration Type NULL(NULL), IPLGCPORT(IP Logic Port), RSCGRP(Resource Group) NULL, IPLGCPORT, RSCGRP None NULL NULL IP path None Read & Write Y IP path Less than 5 minutes None
CARRYT The bearing type of the logic port BSC6900 ADD IPLOGICPORT(Optional) Bearer type of the logical port None None Enumeration Type ETHER, IPLOGICPORT, TRUNK, PPP, MP ETHER, IPLOGICPORT, TRUNK, PPP, MP None None None IP logical port None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
CARRYT Carry port type BSC6900 STR IPCHK(Optional) Port type of the SBFD/ARP bearer GBFD-118609IP Fault Detection Based on BFD Enumeration Type ETHPORT, TRUNKETHPORT, TRUNK None None None None None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
CAS0 Common Alm Switch Enabled1~8 BSC6900 SET BTSDEMUBP(Optional) Whether the common Boolean alarms 1 to 8 reserved by the system are enabled. These common Boolean alarms can be customized according to the actual input Boolean value defined by field engineers. These Boolean alarms are enabled by default.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. MRFD-210304Faulty Management Bit Field Type NO1DISABLE, NO2DISABLE, NO3DISABLE, NO4DISABLE, NO5DISABLE, NO6DISABLE, NO7DISABLE, NO8DISABLE NO1DISABLE, NO2DISABLE, NO3DISABLE, NO4DISABLE, NO5DISABLE, NO6DISABLE, NO7DISABLE, NO8DISABLE None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CAS1 Common Alm Switch Enabled9~16 BSC6900 SET BTSDEMUBP(Optional) Whether the common Boolean alarms 9 to 16 reserved by the system are enabled. These common Boolean alarms can be customized according to the actual input Boolean value defined by the field engineers. These Boolean alarms are enabled by default.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. MRFD-210304Faulty Management Bit Field Type NO9DISABLE, NO10DISABLE, NO11DISABLE, NO12DISABLE, NO13DISABLE, NO14DISABLE, NO15DISABLE, NO16DISABLE NO9DISABLE, NO10DISABLE, NO11DISABLE, NO12DISABLE, NO13DISABLE, NO14DISABLE, NO15DISABLE, NO16DISABLE None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CAS2 Common Alm Switch Enabled17~24 BSC6900 SET BTSDEMUBP(Optional) Whether the common Boolean alarms 17 to 24 reserved by the system are enabled. These common Boolean alarms can be customized according to the actual input Boolean value defined by the field engineers. These Boolean alarms are enabled by default.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. MRFD-210304Faulty Management Bit Field Type NO17DISABLE, NO18DISABLE, NO19DISABLE, NO20DISABLE, NO21DISABLE, NO22DISABLE, NO23DISABLE, NO24DISABLE NO17DISABLE, NO18DISABLE, NO19DISABLE, NO20DISABLE, NO21DISABLE, NO22DISABLE, NO23DISABLE, NO24DISABLE None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CAS3 Common Alm Switch Enabled25~32 BSC6900 SET BTSDEMUBP(Optional) Whether the common Boolean alarms 25 to 32 reserved by the system are enabled. These common Boolean alarms can be customized according to the actual input Boolean value defined by the field engineers. These Boolean alarms are enabled by default.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. MRFD-210304Faulty Management Bit Field Type NO25DISABLE, NO26DISABLE, NO27DISABLE, NO28DISABLE, NO29DISABLE, NO30DISABLE, NO31DISABLE, NO32DISABLE NO25DISABLE, NO26DISABLE, NO27DISABLE, NO28DISABLE, NO29DISABLE, NO30DISABLE, NO31DISABLE, NO32DISABLE None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CASV0 Common Alm Switch Valid vol. Level1~8 BSC6900 SET BTSDEMUBP(Optional) Voltage level of common Boolean alarms 1 to 8. The alarms are classified into high level alarms and low level alarms according to the voltage level. All these alarms are low level alarms by default.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. MRFD-210304Faulty Management Bit Field Type NO1LOW, NO2LOW, NO3LOW, NO4LOW, NO5LOW, NO6LOW, NO7LOW, NO8LOW NO1LOW, NO2LOW, NO3LOW, NO4LOW, NO5LOW, NO6LOW, NO7LOW, NO8LOW, None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CASV1 Common Alm Switch Valid vol. Level9~16 BSC6900 SET BTSDEMUBP(Optional) Voltage level of common Boolean alarms 9 to 16. The alarms are classified into high level alarms and low level alarms according to the voltage level. All these alarms are low level alarms by default.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. MRFD-210304Faulty Management Bit Field Type NO9LOW, NO10LOW, NO11LOW, NO12LOW, NO13LOW, NO14LOW, NO15LOW, NO16LOW NO9LOW, NO10LOW, NO11LOW, NO12LOW, NO13LOW, NO14LOW, NO15LOW, NO16LOW None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CASV2 Common Alm Switch Valid vol. Level17~24 BSC6900 SET BTSDEMUBP(Optional) Voltage level of common Boolean alarms 17 to 24. The alarms are classified into high level alarms and low level alarms according to the voltage level. All these alarms are low level alarms by default.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. MRFD-210304Faulty Management Bit Field Type NO17LOW, NO18LOW, NO19LOW, NO20LOW, NO21LOW, NO22LOW, NO23LOW, NO24LOW NO17LOW, NO18LOW, NO19LOW, NO20LOW, NO21LOW, NO22LOW, NO23LOW, NO24LOW None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CASV3 Common Alm Switch Valid vol. Level25~32 BSC6900 SET BTSDEMUBP(Optional) Voltage level of common Boolean alarms 25 to 32. The alarms are classified into high level alarms and low level alarms according to the voltage level. All these alarms are low level alarms by default.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. MRFD-210304Faulty Management Bit Field Type NO25LOW, NO26LOW, NO27LOW, NO28LOW, NO29LOW, NO30LOW, NO31LOW, NO32LOW NO25LOW, NO26LOW, NO27LOW, NO28LOW, NO29LOW, NO30LOW, NO31LOW, NO32LOW None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CBA Cell bar access BSC6900 SET GCELLIDLEBASIC(Optional) Used together with "Cell bar qualify" to decide the priority status of a cell. Refer to GSM Rec. 04.08.Cell bar qualify Cell bar access Cell selection priority Cell reselection priorityNO NO Normal NormalNO YES Prohibited ProhibitedYES NO Low NormalYES YES Low Normal GBFD-110401GBFD-110402 Basic Cell SelectionBasic Cell Re-selection Enumeration Type NO(NO), YES(YES) NO, YES None None The CBA function applies to special scenarios. If this parameter is set to YES and "Cell bar qualify" is set to no, only handovers are allowed in a cell, and direct access of an MS is not allowed. This condition applies to a dual-network coverage cell. For a common cell, this parameter should be set to NO. Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved If the value of "Cell bar access" is YES and the value of "Cell bar qualify" is NO, new call access is prohibited but handover access is allowed.
CBCINDEX CBC INDEX BSC6900 ADD GCBSADDR(Mandatory) Uniquely identifying a cell broadcast center (CBC) GBFD-113601Short Message Service Cell Broadcast (TS23) Interval Type 0~3 0~3 None None None BSC6900None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
CBCIP CBC IP BSC6900 ADD GCBSADDR(Mandatory) IP address of a CBC GBFD-113601Short Message Service Cell Broadcast (TS23) IP Address Type None 0.0.0.0~255.255.255.255 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CBCITFPARA CBC ITF Para BSC6900 ADD GCBSADDR(Optional) CBC interface parameter. The value of this parameter must be translated into a binary numeral. The following describe each bit of the value:Bit 0: phase flagBit 1: message type flagBit 2: cell list flagBit 3: whether to carry a recovery indicationBit 4: whether to carry a cell IDBit 5: whether to carry a recovery indication during resetting GBFD-113601Short Message Service Cell Broadcast (TS23) Interval Type 0~63 0~63 None 30 30 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CBCPORT CBC Port BSC6900 ADD GCBSADDR(Mandatory) Port number at the CBC side in the communication with the BSC GBFD-113601Short Message Service Cell Broadcast (TS23) Interval Type 0~65535 0~65535 None None 6000 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CbNonMsgTimer Cb No Message Disconnection Timer BSC6900 SET BSCTMR(Optional) Duration of no cell broadcast message at the Cb interface. If the BSC does not receive any message from the CBC during the preset value of this parameter, the BSC considers that the connection with the CBC has been broken and reestablishes a connection. GBFD-113601Short Message Service Cell Broadcast (TS23) Interval Type 5~180 5~180 s None 15 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CBQ Cell bar qualify BSC6900 SET GCELLIDLEBASIC(Optional) Used together with "Cell bar access" to decide the priority status of a cell. See GSM Rec. 0408. This parameter does not affect cell reselection but cell selection only.Cell bar qualify Cell bar access Cell selection priority Cell reselection priorityNO NO Normal NormalNO YES Prohibited ProhibitedYES NO Low NormalYES YES Low Normal GBFD-110401Basic Cell Selection Enumeration Type NO(No), YES(Yes)NO, YES None None NO Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved If the value of "Cell bar access" is YES and the value of "Cell bar qualify" is NO, new call access is prohibited but handover access is allowed.
CBS Consent burst size [Byte] BSC6900 ADD IPLOGICPORT(Optional) Maximum burst size (MBS) None None Interval Type 4500~32767 4500~32767 byte 4500 4500 IP logical port None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CBSCTHD CBS control threshold BSC6900 SET FCCPUTHD(Optional) CPU usage threshold for Cell Broadcast Service (CBS) flow control. When the average CPU usage of sliding windows reaches or exceeds the threshold, CBS flow control is triggered. This parameter is valid only when "Board Class" is "XPU". WRFD-040100Flow Control Interval Type 30~100 30~100 per cent None 85 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CBSCTHD CBS control threshold BSC6900 SET FCMSGQTHD(Optional) Packet queue usage threshold for CBS flow control. When the average packet queue usage of sliding windows reaches or exceeds the threshold, CBS flow control is triggered. This parameter is valid only when "Board Class" is "XPU". WRFD-040100Flow Control Interval Type 30~100 30~100 per cent None 80 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CbShakeHandTimer Cell Broadcast Handshake Timer BSC6900 SET BSCTMR(Optional) Timer interval for sending handshake messages. According to the value of this parameter, the BSC regularly sends the CBC a handshake message to decide whether the communication between the BSC and the CBC is normal. GBFD-113601Short Message Service Cell Broadcast (TS23) Interval Type 1~5 1~5 s None 3 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CBSIGNLEN Filter length for sdcch cv_bep BSC6900 SET GCELLHOFITPEN(Optional) Number of enhanced measurement reports (EMRs) sampled for averaging the CV_BEP on the SDCCH. Averaging the CV_BEP in multiple EMRs helps to prevent the incomprehensiveness of a single EMR. GBFD-117501Enhanced Measurement Report(EMR) Interval Type 0~31 0~31, step:480 for TCH and 470 for SDCCH ms None 2 Cell This parameter is valid only when "MEASURETYPE" in "SET GCELLCCUTRANSYS" is set to EnhMeasReport. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CBSRTHD CBS restore threshold BSC6900 SET FCCPUTHD(Optional) CPU usage threshold for recovery from CBS flow control. When the average CPU usage of sliding windows is lower than the threshold, CBS flow control is stopped. This parameter is valid only when "Board Class" is "XPU". WRFD-040100Flow Control Interval Type 30~100 30~100 per cent None 75 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CBSRTHD CBS restore threshold BSC6900 SET FCMSGQTHD(Optional) Packet queue usage threshold for recovery from CBS flow control. When the average packet queue usage of sliding windows is lower than the threshold, CBS flow control is stopped. This parameter is valid only when "Board Class" is XPU. WRFD-040100Flow Control Interval Type 30~100 30~100 per cent None 70 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CBSSW CBS flow control switch BSC6900 SET FCSW(Optional) Whether to control CBS flow WRFD-040100Flow Control Enumeration Type ON, OFF ON, OFF None None ON Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CBTRAFFLEN Filter length for tch cv_bep BSC6900 SET GCELLHOFITPEN(Optional) Number of enhanced measurement reports (EMRs) sampled for averaging the CV_BEP on the TCH. Averaging the CV_BEP in multiple EMRs helps to prevent the incomprehensiveness of a single EMR. GBFD-117501Enhanced Measurement Report(EMR) Interval Type 0~31 0~31, step:480 for TCH and 470 for SDCCH ms None 6 Cell This parameter is valid only when "MEASURETYPE" in "SET GCELLCCUTRANSYS" is set to EnhMeasReport. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CC CC BSC6900 SET BSCBASIC(Optional) Country code, for example, 86 for China MRFD-210301Configuration Management Interval Type 0~65535 0~65535 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CCAEnableSta Certificate Chain File Enabled State BSC6900 SET CERTFILE(Optional) Whether to enable the certificate chainDISABLE: indicating that the certificate chain is disabledENABLE: indicating that the certificate chain is enabled MRFD-210305Security Management Enumeration Type DISABLE(Disable), ENABLE(Enable) DISABLE, ENABLE None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CCCHLOADINDPRD CCCH Load Indication Period BSC6900 SET GCELLCCCH(Optional) Time interval for sending overload messages, used for the BTS to notify the BSC of the load over a specific CCCH timeslot. See GSM Rec. 0508. GBFD-111003Radio Common Channel Management Interval Type 0~255 0~255 s None 15 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CCCHLOADTHRES CCCH Load Threshold BSC6900 SET GCELLCCCH(Optional) Used for the BTS to notify the BSC of the load over a specific CCCH timeslot, that is, the load of the access request messages over the RACHs and all the messages (including paging and packet immediate assignment messages) over the PCHs. See GSM Rec. 0858. GBFD-111003Radio Common Channel Management Interval Type 20~100 20~100 per cent None 80 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CCDSCP DSCP of CONV[QoS] BSC6900 SET BSCPSTCDSCPMAP(Optional) DSCP corresponding to the session service. GBFD-118603Gb over IP Interval Type 0~63 0~63 None None 46 BSC None Read & Write Not involved Not involved Not involved None
CCHPRIPATH Common channel primary path BSC6900 ADD TRMMAP(Optional) Common channel service bearer primary path None None Enumeration Type CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF None None When the interface type is Iub, transmission type is ATM or dual stack, the parameter is RT_VBR; transimssion type is IP or Hybird IP, the parameter is EF.When the interface type is Iur, transmission type is ATM, the parameter is RT_VBR; transimssion type is IP, the parameter is EF. BSC6900When the value of "ITFT" in "ADD TRMMAP" is set to IUB or IUR, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node configured with the TRMMAP. After the successful modification, it is valid in the case of the new access of a subscriber and the bandwidth modification of an existing subscriber.
CCHSECPATH Common channel secondary path BSC6900 ADD TRMMAP(Optional) Common channel service bearer secondary path None None Enumeration Type CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF, NULL CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF, NULL None None When the interface type is Iub, transmission type is ATM or IP, the parameter is NULL; transimssion type is dual stack, the parameter is EF; transimssion type is Hybird IP, the parameter is LQEF.When the interface type is Iur, transmission type is ATM or IP, the parameter is NULL. BSC6900When the value of "ITFT" in "ADD TRMMAP" is set to IUB or IUR, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node configured with the TRMMAP. After the successful modification, it is valid in the case of the new access of a subscriber and the bandwidth modification of an existing subscriber.
CCMINTERVAL CCM Send Prid BSC6900 ADD ETHMA(Optional) Transmission period of the CCM packet in the MA GBFD-118630Ethernet OAM Enumeration Type 10, 100, 1000 10, 100, 1000 ms 1000 1000 Ethernet port None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
CDRTTRYFBDTHRES Cell Directed Retry Forbidden Threshold BSC6900 SET GCELLOTHEXT(Optional) Threshold of forbidding directed retry for cells. When the value of "Assignment Cell Load Judge Enable" in "SET GCELLCCBASIC" is ENABLE, if cells support directed retry and the current cell load is greater than or equal to the value of this parameter, the BSC allocates a channel to an MS through the process of directed retry. GBFD-110607Direct Retry Interval Type 0~100 0~100 per cent None 90 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CELL1800OFF 1800 Reporting Offset BSC6900 SET GCELLCCUTRANSYS(Optional) Offset of the measurement report about the cells at the 1800 MHz frequency. Before cells are sequenced by priority according to frequencies, the value of this parameter must be added to the receive level value in the measurement report about the cells at the 1800 MHz frequency. GBFD-114301GBFD-114302 GSM/WCDMA InteroperabilityGSM/TD-SCDMA Interoperability Interval Type 0~7 0~7, step: 6 dB None 0 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CELL1800THRED 1800 Reporting Threshold BSC6900 SET GCELLCCUTRANSYS(Optional) Threshold of the measurement report about the cells at the 1800 MHz frequency. When the receive level value in the measurement report about the cells at the 1800 MHz frequency exceeds the value of this parameter, the report takes effect. After being filtered, the measurement report is used for priority sequencing of cells. The value 7 means infinite. GBFD-114301GBFD-114302 GSM/WCDMA InteroperabilityGSM/TD-SCDMA Interoperability Interval Type 0~7 0~7, step: 6 dB None 0 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CELL2GBA1BCCH 2G NCELL BCCH BSC6900 SET GCELL2GBA1(Mandatory) BCCH frequency of a 2G neighbor cell that MSs can measure in idle mode. Recording the BCCH frequencies of 2G neighbor cells that MSs can measure in idle mode, the BA1 table is sent in System Information 2, 2bis, and 2ter. MRFD-210301Configuration Management Interval Type 0~1023 0~1023 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CELL2GBA1TAG 2GBA1 Input Tag BSC6900 SET GCELL2GBA1(Mandatory) Whether to generate the 2G BA1 table automatically according to neighbor cell relations or to input the 2G BA1 table manually. Recording the BCCH frequencies of 2G neighbor cells that MSs can measure in idle mode, the BA1 table is sent in System Information 2, 2bis, and 2ter. MRFD-210301Configuration Management Enumeration Type AUTO(Auto), MANU(Manu) AUTO, MANU None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CELL2GBA2BCCH 2G NCELL BCCH BSC6900 SET GCELLHO2GBA2(Mandatory) BCCH frequency of a 2G neighbor cell that MSs can measure in dedicated mode. Recording the BCCH frequencies of 2G neighbor cells that MSs can measure in dedicated mode, the BA2 table is sent in System Information 5, 5bis, and 5ter. MRFD-210301Configuration Management Interval Type 0~1023 0~1023 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CELL2GBA2TAG 2GBA2 Input Tag BSC6900 SET GCELLHO2GBA2(Mandatory) This parameter indicate whether to generate the 2G BA2 table automatically according to neighbor cell relations or to input the 2G BA2 table manually. Recording the BCCH frequencies of 2G neighbor cells that MSs can measure in dedicated mode, the BA2 table is sent in System Information 5, 5bis, and 5ter. MRFD-210301Configuration Management Enumeration Type AUTO(Auto), MANU(Manu) AUTO, MANU None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CELL8PSKPOWERLEVEL Cell 8PSK Power Attenuation Grade BSC6900 SET GCELLBASICPARA(Optional) Timeslot power attenuation grade of the EDGE TRX in 8PSK modulation mode. There are 50 attenuation grades, each of which corresponds to an attenuation of 0.2 dB. When the EDGE TRX sends signals in 8PSK modulation mode, the transmit power must be lower than the mean power in GMSK modulation mode. GBFD-119115Power Control Interval Type 0~50 0~50 None None 0 Cell This parameter is valid only when "EDGE" in "SET GCELLGPRS" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter applies to only the EDGE trx.
CELL900OFF 900 Reporting Offset BSC6900 SET GCELLCCUTRANSYS(Optional) Offset of the measurement report about the cells at the 900 MHz frequency. Before cells are sequenced by priority according to frequencies, the value of this parameter must be added to the receive level value in the measurement report about the cells at the 900 MHz frequency. GBFD-114301GBFD-114302 GSM/WCDMA InteroperabilityGSM/TD-SCDMA Interoperability Interval Type 0~7 0~7, step: 6 dB None 0 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CELL900THRED 900 Reporting Threshold BSC6900 SET GCELLCCUTRANSYS(Optional) Threshold of the measurement report about the cells at the 900 MHz frequency. When the receive level value in the measurement report about the cells at the 900 MHz frequency exceeds the value of this parameter, the report takes effect. After being filtered, the measurement report is used for priority sequencing of cells. The value 7 means infinite. GBFD-114301GBFD-114302 GSM/WCDMA InteroperabilityGSM/TD-SCDMA Interoperability Interval Type 0~7 0~7, step: 6 dB None 0 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CELLBARACCESS2 Cell Access Bar Switch BSC6900 SET GCELLSERVPARA(Optional) Whether the cell can be added to the reselected candidate cell list. If this parameter is set to "NoPermit", the cell cannot be reselected as the candidate cell for handover. If this parameter is set to "Permit", the cell can be reselected as the candidate cell for handover. GBFD-114101GPRS Enumeration Type Permit(Permit Cell Access), NoPermit(Prohibit Cell Access) Permit, NoPermit None None Permit Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CELLCOVERAGETYPE Cell Coverage Type BSC6900 SET GCELLOTHEXT(Optional) If the coverage type of a cell is outdoor coverage, the BTS detects whether the standing wave alarm is generated only when the forward power is greater than 35 dBm. If the coverage type of a cell is indoor coverage, the BTS detects whether the standing wave radio alarm is generated only when the forward power is greater than 30 dBm. GBFD-111202O&M of BTS Enumeration Type OUTDOOR_CELL(Outdoor Cell), INDOOR_CELL(Indoor Cell) OUTDOOR_CELL, INDOOR_CELL None OUTDOOR_CELL OUTDOOR_CELL Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CELLEQUCHGVOL Even charging voltage BSC6900 SET BTSPMUBP(Optional) Even charging voltage of the battery. The battery is charged at the voltage as specified by this parameter. GBFD-111202O&M of BTS Interval Type 240~289 24~28.9 (step: 0.1) V 283 None BTS The value of this parameter must be greater than "Float charging voltage" and at least one volt lower than "DC overvoltage alarm threshold". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CELLEQUCHGVOL Even Charging Voltage BSC6900 SET BTSDPMUBP(Optional) Even charging voltage of the battery. The battery is charged at the voltage as specified by this parameter.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. GBFD-111202O&M of BTS Interval Type 433~576 43.3~57.6 (step: 0.1) V None None BTS The value of this parameter must be greater than "Float charging voltage" and at least three volts lower than "DC overvoltage alarm threshold". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CELLFLOATCHGVOL Float charging voltage BSC6900 SET BTSPMUBP(Optional) Float charging voltage of the battery. The battery is charged at the voltage as specified by this parameter. GBFD-111202O&M of BTS Interval Type 240~289 24~28.9 (step: 0.1) V 268 None BTS The value of this parameter must be smaller than "Even Charging Voltage". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CELLFLOATCHGVOL Float Charging Voltage BSC6900 SET BTSDPMUBP(Optional) Float charging voltage of the battery. The battery is charged at the voltage as specified by this parameter.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. GBFD-111202O&M of BTS Interval Type 432~575 43.2~57.5 (step: 0.1) V None None BTS The value of this parameter must be smaller than "Even Charging Voltage". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CELLID Cell Index BSC6900 ADD GCELLFREQ(Mandatory)ADD GCELLHOPANTGRP(Mandatory)ADD GCELLMAGRP(Mandatory)ADD GCELLOSPMAP(Mandatory)SET GCELLAMRQUL(Mandatory)SET GCELLBASICPARA(Mandatory)SET GCELLCCACCESS(Mandatory)SET GCELLCCAD(Mandatory)SET GCELLCCTMR(Mandatory)SET GCELLCCUTRANSYS(Mandatory)SET GCELLEXTMSRPARA(Mandatory)SET GCELLGSMR(Mandatory)SET GCELLIDLEBASIC(Mandatory)SET GCELLIDLEFDDBA1(Mandatory)SET GCELLIDLETDDBA1(Mandatory)SET GCELLLCS(Mandatory)SET GCELLOTHBASIC(Mandatory)SET GCELLRACHCCLEV(Mandatory)SET GCELLREV(Mandatory)SET GCELLSBC(Mandatory)SET GCELLSOFT(Mandatory)SET GCELLTMR(Mandatory)SET GCELLADMSTAT(Mandatory)ADD GCELL(Mandatory)SET GCELLCCBASIC(Mandatory)SET GCELLCCAMR(Mandatory)SET GCELLIDLEAD(Mandatory)SET GCELLCCCH(Mandatory)SET GCELLOTHEXT(Mandatory)SND GCELLSYSMSG(Mandatory)SET FHO(Mandatory)SET GCELL2GBA1(Mandatory)SET GCELLCHMGBASIC(Mandatory)SET GCELLHO2GBA2(Mandatory)SET GCELLHOAD(Mandatory)SET GCELLHOBASIC(Mandatory)SET GCELLHOCTRL(Mandatory)SET GCELLHOEDBPARA(Mandatory Index of a cell, uniquely identifying a cell in a BSC MRFD-210301Configuration Management Interval Type 0~2047 0~2047 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CELLID Cell Index BSC6900 SET GMRSCOPE(Mandatory) ID of the cell. The cell ID cannot conflict with other cell IDs in the BSC. MRFD-210301Configuration Management Interval Type 0~2047 0~2047 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CELLID Cell Index BSC6900 SET GCELLHOINTERRATLDB(Mandatory) Index of a cell, uniquely identifying a cell in a BSC MRFD-211402MBSC Load Balancing Interval Type 0~2047 0~2047 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CELLID Cell Index BSC6900 ADD BTSAUTOPLAN(Optional) Index of the cell. It uniquely identifies a cell. MRFD-210301Configuration Management Interval Type 0~2047 0~2047 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CELLID Cell Index BSC6900 SAV GCELLTEMPLATE(Mandatory) Cell Index GBFD-111202O&M of BTS Interval Type 0~2047 0~2047 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CELLIDLST Cell List BSC6900 STR NCS(Mandatory) List of the user-defined neighbor cells to be measured. This parameter is represented as a character string where the IDs of the cells to be measured are separated by &, such as 1&2&5.The BSC supports up to 50 cells. GBFD-5109012G/3G Neighboring Cell Automatic Optimization String Type None 1~400 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CELLIDTYPE Cell Index Type BSC6900 SET FHO(Mandatory) Type of indexing the cell when this commond is executed MRFD-210301Configuration Management Enumeration Type BYNAME(By name), BYID(By index) BYNAME, BYID None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CELLIDTYPE Cell Index Type BSC6900 ADD BTSRETANT(Mandatory) Type of an index MRFD-210301Configuration Management Enumeration Type BYNAME(By Name), BYID(By Index) BYNAME, BYID None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CELLIDTYPE Cell Index Type BSC6900 SET BTSANTANGLE(Mandatory) Index type of the cell. BYNAME: query by cell name; BYID: query by cell index. MRFD-210602Remote Electrical Tilt Enumeration Type BYNAME(By Name), BYID(By Index) BYNAME, BYID None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CELLINEXTP Cell Inner/Extra Property BSC6900 ADD GCELL(Mandatory) Whether a cell is an inner or extra cell in an enhanced dual band network GBFD-114402Enhanced Dual-Band Network Enumeration Type Inner(Inner), Extra(Extra) Inner, Extra None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CELLLAYER Layer of the cell BSC6900 ADD GEXT3GCELL(Optional) A network basically consists of four layers, namely, Umbrella, Macro, Micro, and Pico. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Enumeration Type 1, 2, 3, 4 1, 2, 3, 4 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CELLLIST Cell Index List BSC6900 ADD GSMSCB(Optional) List of cell indexes. All cell indexes are combined as a character string, separated by "&". For example, 1&2&5. MRFD-210301Configuration Management String Type None 0~5000 characters None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CellListOptionSend Cell List Send Flag in ASS CMP BSC6900 SET MSGSOFTPARA(Optional) Whether an assignment complete message contains a cell list.According to GSM Rec. 08.08, during a channel assignment, an assignment complete message contains a cell list only when the cell of the MS changes.For the MSCs of some vendors, however, assignment complete messages must contain cell lists. To meet such a requirement, the value of this parameter must be YES. GBFD-111804A Interface Protocol Process Enumeration Type NO(No), YES(Yes)NO, YES None None NO MSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The setting of this parameter needs negotiation with the opposite network element MSC.If the MSC supports processing assignment complete messages containing cell lists, set this parameter to YES; otherwise, set this parameter to NO.
CELLMAXSD Cell SDCCH Channel Maximum BSC6900 SET GCELLCHMGBASIC(Optional) Maximum number of SDCCHs in the cell. Before converting a TCH into an SDCCH, the BSC compares the number of SDCCHs after the conversion in the cell with "Cell SDCCH Channel Maximum". If the number of SDCCHs after the conversion in the cell exceeds this parameter, the BSC does not convert the TCH into an SDCCH. GBFD-113001SDCCH Dynamic Adjustment Interval Type 0~255 0~255 None None 80 Cell This parameter is valid only when "SDDYN" in "SET GCELLBASICPARA" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CELLNAME Cell Name BSC6900 ADD GCELLFREQ(Mandatory)ADD GCELLHOPANTGRP(Mandatory)ADD GCELLMAGRP(Mandatory)ADD GCELLOSPMAP(Mandatory)SET GCELLAMRQUL(Mandatory)SET GCELLBASICPARA(Mandatory)SET GCELLCCACCESS(Mandatory)SET GCELLCCAD(Mandatory)SET GCELLCCTMR(Mandatory)SET GCELLCCUTRANSYS(Mandatory)SET GCELLEXTMSRPARA(Mandatory)SET GCELLGSMR(Mandatory)SET GCELLIDLEBASIC(Mandatory)SET GCELLIDLEFDDBA1(Mandatory)SET GCELLIDLETDDBA1(Mandatory)SET GCELLLCS(Mandatory)SET GCELLOTHBASIC(Mandatory)SET GCELLRACHCCLEV(Mandatory)SET GCELLREV(Mandatory)SET GCELLSBC(Mandatory)SET GCELLSOFT(Mandatory)SET GCELLTMR(Mandatory)SET GCELLADMSTAT(Mandatory)ADD GCELL(Mandatory)SET GCELLCCBASIC(Mandatory)SET GCELLCCAMR(Mandatory)SET GCELLIDLEAD(Mandatory)SET GCELLCCCH(Mandatory)SET GCELLOTHEXT(Mandatory)SND GCELLSYSMSG(Mandatory)SET FHO(Mandatory)SET GCELL2GBA1(Mandatory)SET GCELLCHMGBASIC(Mandatory)SET GCELLHO2GBA2(Mandatory)SET GCELLHOAD(Mandatory)SET GCELLHOBASIC(Mandatory)SET GCELLHOCTRL(Mandatory)SET GCELLHOEDBPARA(Mandatory Name of a cell, uniquely identifying a cell in a BSC. MRFD-210301Configuration Management String Type None 1~64 characters None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CELLNAME Cell Name BSC6900 SET GCELLHOINTERRATLDB(Mandatory) Name of a cell, uniquely identifying a cell in a BSC MRFD-211402MBSC Load Balancing String Type None 1~64 characters None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CELLNAME Cell Name BSC6900 ADD BTSAUTOPLAN(Mandatory)SAV GCELLTEMPLATE(Mandatory) Name of a cell.GBFD-111202O&M of BTS String Type None 1~64 characters None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CELLNAMELIST Cell Name List BSC6900 ADD GSMSCB(Optional) List of cell names. All cell names are combined as a character string, separated by "&". For example, cell1&cell2&cell5. The cell name should not contain the following characters:? | : < > " @# ! % ^ & * . [ ] / \ \\ ' MRFD-210301Configuration Management String Type None 0~5000 characters None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CELLOVERCVGRXLEVDLTH Cell Over Coverage DL RxLev Threshold BSC6900 SET GCELLOTHEXT(Optional) Threshold of the downlink receive level of an over-coverage cell. If the downlink level of a cell is higher than the value of this parameter and the timing advance (TA) is greater than the value of "Cell Over Coverage TA Threshold" in more than 20% measurement reports, the cell is defined as an over-coverage cell. GBFD-110801GBFD-110802 Processing of Measurement ReportPre-processing of Measurement Report Interval Type 0~63 0~63 dB None 30 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CELLOVERCVGTALTH Cell Over Coverage TA Threshold BSC6900 SET GCELLOTHEXT(Optional) Threshold of the TA of an over-coverage cell. If the downlink level of a cell is higher than the value of this parameter and the timing advance (TA) is greater than the value of "Cell Over Coverage TA Threshold" in more than 20% measurement reports, the cell is defined as an over-coverage cell. GBFD-110801GBFD-110802 Processing of Measurement ReportPre-processing of Measurement Report Interval Type 0~63 0~63 None None 1 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CELLPAGINGOVERLOADCOUNTER Cell Paging Overload Threshold BSC6900 SET GCELLSOFT(Optional) Maximum number of reported paging overload messages in the cell. If the BSC allows the flow control on the re-paging messages, and the number of the reported paging overload messages exceeds the value of this parameter, the BSC determines that the cell is in PCH overload state. GBFD-111003Radio Common Channel Management Interval Type 1~20 1~20 None None 4 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CELLPWROFFEN Battery Power-off Allowed State BSC6900 SET BTSDPMUBP(Optional) Whether to allow the power-off of the battery.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. GBFD-111202O&M of BTS Enumeration Type NO(NO), YES(YES) NO, YES None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CELLPWROFFVOL Battery Power-off Voltage BSC6900 SET BTSDPMUBP(Optional) Battery power-off voltage.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. GBFD-111202O&M of BTS Interval Type 350~553 35.0~55.3 (step: 0.1) V None 430 BTS The value of this parameter must be smaller than "DC undervoltage alarm threshold". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CELLRESELSTRATEGY 2G/3G Cell Reselection Strategy BSC6900 SET GCELLNC2PARA(Optional) This parameter specifies whether a 2G cell or 3G cell is selected in the inter-RAT cell reselection procedure. GBFD-116201Network-Controlled Cell Reselection (NC2) Enumeration Type 2G(Preference for 2G Cell), 3G(Preference for 3G Cell) 2G, 3G None None 2G Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CELLRXQUALWORSENRATIOTHRSH Cell Rx Quality Worsen Ratio Threshold BSC6900 SET GCELLNC2PARA(Optional) This parameter specifies that the accumulatively calculated number of times that the downlink transmission quality of MS is lower than the transmission quality threshold of MS. The critical reselection needs to be performed when the ratio of the accumulatively calculated number of times and the number of times in the downlink transmission quality measurement report reaches this threshold. GBFD-116201Network-Controlled Cell Reselection (NC2) Interval Type 0~100 0~100 None None 30 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CELLSCENARIO Cell Scenario BSC6900 SET GCELLBASICPARA(Optional) Information about cell scenario should be sent to the BTS. Based on the information, the BTS optimizes the allocation of resources. GBFD-510803GBFD-510804 Uplink EGPRS2-ADownlink EGPRS2-A Enumeration Type COMMON(COMMON), MULTIPATH(MULTIPATH), INDOOR(INDOOR), HIGHWAY(HIGHWAY) COMMON, MULTIPATH, INDOOR, HIGHWAY None None COMMON Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CELLSELECTAFTERCALLREL Select 3G Cell After Call Release BSC6900 SET GCELLCCAD(Optional) Whether an MS prioritizes a 3G cell after a call is released in an overlapped coverage area of the 2G and 3G networks. GBFD-114325Fast 3G Reselection at 2G CS Call Release Enumeration Type NO(No), YES(Yes)NO, YES None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CELLTEMP1ALARMH High Temp Alarm Assembled Bat1 BSC6900 SET BTSDPMUBP(Optional) The BTS reports an alarm if the temperature of battery group 1 exceeds the value of this parameter.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. MRFD-210304Faulty Management Interval Type 400~790 40~79 (step: 0.1) degree Celsius None 500 BTS The value of this parameter must be smaller than "Low Temp Alarm Assembled Bat2". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
5/5/2014
Confidential Information of Huawei.
No Spreading without Permission
Page5of42
226347869.xls.ms_office Security Level:
CELLTEMP1ALARML Low Temp Alarm Assembled Bat1 BSC6900 SET BTSDPMUBP(Optional) The BTS reports an alarm if the temperature of battery group 1 is lower than the value of this parameter.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. MRFD-210304Faulty Management Interval Type -190~50 -19.0~5.0 (step: 0.1) degree Celsius None -100 BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CELLTEMP1THRESHOLDH Upper assembled bat 1 temp BSC6900 SET BTSAPMUBP(Optional)SET BTSDPMUBP(Optional) Upper limit of the temperature measured by the temperature sensor of the battery group 1. If the measured value is greater than the value of this parameter, the value of this parameter is reported.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. GBFD-111202O&M of BTS Interval Type 0~1000 0~100 (step: 0.1) degree Celsius None 800 BTS The value of this parameter must be greater than "Lower Assembled Bat1 TEMP Measure". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CELLTEMP1THRESHOLDL Lower Assembled Bat1 TEMP Measure BSC6900 SET BTSAPMUBP(Optional)SET BTSDPMUBP(Optional) Lower limit of the temperature measured by the temperature sensor of the battery group 1. If the measured value is smaller than the value of this parameter, the value of this parameter is reported.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. GBFD-111202O&M of BTS Interval Type -500~0 -50~0 (step: 0.1) degree Celsius None -200 BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CELLTEMPCOMPENABLED Bat temp compensated configure enabled BSC6900 SET BTSAPMUBP(Optional)SET BTSDPMUBP(Optional) Whether to allow the configuration of parameters related to the temperature compensation of the battery groupIn multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. GBFD-111202O&M of BTS Enumeration Type NO(NO), YES(YES) NO, YES None None NO BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CELLURACTHD Cell URA update control threshold BSC6900 SET FCCPUTHD(Optional) CPU usage threshold for cell update. When the average CPU usage of sliding windows reaches or exceeds the threshold, cell update control is triggered. This parameter is valid only when "Board Class" is "XPU". WRFD-040100Flow Control Interval Type 30~100 30~100 per cent None 85 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CELLURACTHD Cell URA update control threshold BSC6900 SET FCMSGQTHD(Optional) Packet queue usage threshold for cell update. When the average packet queue usage of sliding windows reaches or exceeds the threshold, cell update control is triggered. This parameter is valid only when "Board Class" is "XPU". WRFD-040100Flow Control Interval Type 30~100 30~100 per cent None 80 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CELLURARTHD Cell URA update restore threshold BSC6900 SET FCCPUTHD(Optional) CPU usage threshold for recovery from cell update control. When the average CPU usage of sliding windows is lower than the threshold, cell update control is stopped. This parameter is valid only when "Board Class" is "XPU". WRFD-040100Flow Control Interval Type 30~100 30~100 per cent None 75 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CELLURARTHD Cell URA update restore threshold BSC6900 SET FCMSGQTHD(Optional) Packet queue usage threshold for recovery from cell update control. When the average packet queue usage of sliding windows is lower than the threshold, cell update control is stopped. This parameter is valid only when "Board Class" is "XPU". WRFD-040100Flow Control Interval Type 30~100 30~100 per cent None 70 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CELLURASW Cell URA update flow control switch BSC6900 SET FCSW(Optional) Whether to control cell updates WRFD-040100Flow Control Enumeration Type ON, OFF ON, OFF None None ON Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CELLWEAKCVGRXLEVDLTH Cell Weak Coverage DL RxLev Threshold BSC6900 SET GCELLOTHEXT(Optional) Threshold of the downlink receive level of an weak-coverage cell. If the downlink level of a cell is lower than the value of this parameter and the timing advance (TA) is smaller than the value of "Cell Weak Coverage TA Threshold" in more than 30% measurement reports, the cell is defined as an weak-coverage cell. GBFD-110801GBFD-110802 Processing of Measurement ReportPre-processing of Measurement Report Interval Type 0~63 0~63 dB None 20 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CELLWEAKCVGTALTH Cell Weak Coverage TA Threshold BSC6900 SET GCELLOTHEXT(Optional) Threshold of the TA of an weak-coverage cell. If the downlink level of a cell is lower than the value of this parameter and the timing advance (TA) is smaller than the value of "Cell Weak Coverage TA Threshold" in more than 30% measurement reports, the cell is defined as an weak-coverage cell. GBFD-110801GBFD-110802 Processing of Measurement ReportPre-processing of Measurement Report Interval Type 0~63 0~63 None None 1 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CENDTHD Congestion End Threshold BSC6900 SET GTRXFC(Optional) Threshold for stopping LAPD link congestion control GBFD-111705GSM Flow Control Interval Type 20~90 20~90 per cent None 60 TRX None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The setting of this parameter must be smaller than "CSTARTTHD".
CertChain Certificate Chain File Name BSC6900 SET CERTFILE(Mandatory) Name of the certificate chain file MRFD-210305Security Management String Type None 0~200 characters None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CFGFLAG Board Parameter Configuration Enabled BSC6900 SET BTSFMUABP(Mandatory)SET BTSNFCBBP(Mandatory)SET BTSPMUBP(Mandatory)SET BTSAPMUBP(Mandatory)SET BTSDATUBP(Mandatory)SET BTSDEMUBP(Mandatory)SET BTSDHEUBP(Mandatory)SET BTSDOMUBP(Mandatory)SET BTSDPMUBP(Mandatory)SET BTSDTMUBP(Mandatory)SET BTSPSUFP(Mandatory)SET BTSDDPUBP(Mandatory)SET BTSUSCUBP(Mandatory) Whether to allow the configuration of alarm parameters. The value "YES" indicates that the configuration is allowed, and the value "NO" indicates that the configuration is not allowed. If the parameter is set to "YES", all the other parameters are reset to the default values in this command.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. GBFD-111202O&M of BTS Enumeration Type NO(NO), YES(YES) NO, YES None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CFGFLAG Carry Flag BSC6900 SET BTSIP(Optional) Whether to indicate that the IP path is carried on the IP logic port or resource group GBFD-118605IP QOS Enumeration Type NULL(NULL), IPLGCPORT(IP Logic Port), RSCGRP(Resource Group) NULL, IPLGCPORT, RSCGRP None NULL None IP path None Read & Write Y IP path Less than 5 minutes None
CFGMODE BTS Configuration Mode BSC6900 SET BTSAUTOPLANCFG(Mandatory) BTS configuration modes include auto plan mode and normal mode. In auto plan mode, the user can enable the auto planning algorithms and auto optimization algorithms according to the BTS type. In normal mode, the auto planning algorithms and auto optimization algorithms are disabled. GBFD-510701Compact BTS Automatic Configuration and Planning Enumeration Type AUTO(AUTOPLAN), NORMAL(NORMAL) AUTO, NORMAL None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CFLAG Board Parameter Configuration Enabled BSC6900 SET BTSCABPARA(Mandatory) Whether to enable the board parameters to be configured. If this parameter is set to "YES", the user can set board parameters of the BTS cabinet. Otherwise, the user cannot set the board parameters. GBFD-111202O&M of BTS Enumeration Type NO(NO), YES(YES) NO, YES None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CFLAG Board Parameter Configuration Enabled BSC6900 SET BTSPOWERTYPE(Mandatory) Whether to enable the board parameters to be configured. If this parameter is set to "YES", the user can set the cabinet power type. Otherwise, the user cannot set the cabinet power type. GBFD-111202O&M of BTS Enumeration Type NO(NO), YES(YES) NO, YES None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CFM Confirm Password BSC6900 ADD OP(Mandatory) Confirm password. The confirm password is required to ensure that a correct password is entered. GBFD-111203MRFD-210305 O&M of BSCSecurity Management Password TypeNone 1~32 characters None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CG Command Group BSC6900 ADD CCG(Mandatory)SET CCGN(Mandatory) Customized command group to be processed GBFD-111203MRFD-210305 O&M of BSCSecurity Management Enumeration Type G_15, G_16, G_17, G_18, G_19, G_20, G_21, G_22, G_23, G_24, G_25, G_26, G_27, G_28, G_29, G_30, G_31 G_15, G_16, G_17, G_18, G_19, G_20, G_21, G_22, G_23, G_24, G_25, G_26, G_27, G_28, G_29, G_30, G_31 None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CG Command Group BSC6900 ADD OP(Optional)This parameter is valid only when the operator belongs to the custom level. GBFD-111203MRFD-210305 O&M of BSCSecurity Management Bit Field Type G_0~0 G_1~1 G_2~2 G_3~3 G_4~4 G_5~5 G_6~6 G_7~7 G_8~8 G_9~9 G_10~10 G_11~11 G_12~12 G_13~13 G_14~14 G_15~15 G_16~16 G_17~17 G_18~18 G_19~19 G_20~20 G_21~21 G_22~22 G_23~23 G_24~24 G_25~25 G_26~26 G_27~27 G_28~28 G_29~29 G_30~30 G_31 G_0, G_1, G_2, G_3, G_4, G_5, G_6, G_7, G_8, G_9, G_10, G_11, G_12, G_13, G_14, G_15, G_16, G_17, G_18, G_19, G_20, G_21, G_22, G_23, G_24, G_25, G_26, G_27, G_28, G_29, G_30, G_31 None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CGET Congestion End Threshold BSC6900 ADD ATERSL(Optional)ADD ATERCONSL(Optional) Congestion end threshold. If the congestion end threshold is large, the congestion control ends earlier. As a result, the congestion control effect is poor. The work of the Ater signaling link is deteriorated. GBFD-111203O&M of BSC Interval Type 20~90 20~90 None 60 60 ATERCONSL None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The congestion start threshold must be greater than the congestion end threshold.
CGET Congestion End Threshold BSC6900 ADD PBSL(Optional) Congestion end threshold. If the congestion end threshold is large, the congestion control ends earlier. As a result, the congestion control effect is poor. The work of the Ater signaling link is deteriorated. GBFD-111203O&M of BSC Interval Type 20~90 20~90 None 60 60 ATERCONSL None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The congestion start threshold must be greater than the congestion end threshold.
CGIRACSWITCH CGI and RAC Plan Switch BSC6900 SET BTSAUTOPLANCFG(Optional) If the parameter is set to 1, it indicates that the CGI and RAC data is generated through automatic planning. If the parameter is set to 0, it indicates that the data needs to be manually entered. GBFD-510701Compact BTS Automatic Configuration and Planning Enumeration Type OFF(OFF), ON(ON) OFF, ON None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CGN Command Group Name BSC6900 SET CCGN(Optional) Name of the command group. You can define the name. GBFD-111203MRFD-210305 O&M of BSCSecurity Management String Type None 1~32 characters None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CGN Cabinet Group No. BSC6900 SET BTSIDLETS(Mandatory) Number of the cabinet group where the idle timeslot is located. GBFD-114101GPRS Interval Type 0~2 0~2 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CGST Congestion Start Threshold BSC6900 ADD ATERSL(Optional) Congestion start threshold. If congestion start threshold is set to a large value, the congestion control becomes a time lag and the work of the signaling link is deteriorated. The interval between congestion start threshold and congestion end threshold should not be too small. Otherwise, the work of the signaling link is instable. The congestion control starts frequently. GBFD-111203O&M of BSC Interval Type 30~100 30~100 None 90 90 BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The congestion start threshold must be greater than the congestion end threshold.
CGST Congestion Start Threshold BSC6900 ADD ATERCONSL(Optional) Congestion start threshold. If congestion start threshold is set to a large value, the congestion control becomes a time lag and the work of the signaling link is deteriorated. The interval between congestion start threshold and congestion end threshold should not be too small. Otherwise, the work of the signaling link is instable. The congestion control starts frequently. GBFD-111203O&M of BSC Interval Type 30~100 30~100 None 90 90 ATERCONSL None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The congestion start threshold must be greater than the congestion end threshold.
CGST Congestion Start Threshold BSC6900 ADD PBSL(Optional) Congestion start threshold. If congestion start threshold is set to a large value, the congestion control becomes a time lag and the work of the signaling link is deteriorated. The interval between congestion start threshold and congestion end threshold should not be too small. Otherwise, the work of the signaling link is instable. The congestion control starts frequently. GBFD-111203O&M of BSC Interval Type 30~100 30~100 None 90 90 BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The congestion start threshold must be greater than the congestion end threshold.
CHAINNCELLTYPE Chain Neighbour Cell Type BSC6900 ADD G2GNCELL(Optional) This parameter indicates the geographical location relation between the neighboring cell and the serving cell. In the BSC, if direction A is selected, then the reverse direction is B. GBFD-510103Chain Cell Handover Enumeration Type QUICK_HO_NCELL_TYPE_A(QUICK_HO_NCELL_TYPE_A), QUICK_HO_NCELL_TYPE_B(QUICK_HO_NCELL_TYPE_B) QUICK_HO_NCELL_TYPE_A, QUICK_HO_NCELL_TYPE_B None QUICK_HO_NCELL_TYPE_A QUICK_HO_NCELL_TYPE_A Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CHAINTORING Combine Type BSC6900 CBN BTSRXUCHAIN(Mandatory) Combination type of RXU chains. "CHAINTORING" indicates that one RXU chain changes to a ring, and "COMBINECHAINS" indicates that two RXU chains are combined into one ring. GBFD-111202O&M of BTS Enumeration Type CHAINTORING(ChainToRing), COMBINECHAINS(CombineRXUChains) CHAINTORING, COMBINECHAINS None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CHALLOCSTRATEGY Channel Allocate Strategy BSC6900 SET GCELLCHMGBASIC(Optional) Channel assignment priority of the cellIf this parameter is set to CAPABILITY, the factors are listed as follows in a descending order of priority: capacity factors, quality factors, PS cooperation factors, and management factors.If this parameter is set to QUALITY, the factors are listed as follows in a descending order of priority: quality factors, capacity factors, PS cooperation factors, and management factors.If this parameter is set to PSRELATIVELY, the factors are listed as follows in a descending order of priority: capacity factors, PS cooperation factors, quality factors, and management factors.If this parameter is set to PSABSOLUTELY, the factors are listed as follows in a descending order of priority: PS cooperation factors, capacity factors, quality factors, and management factors. GBFD-111005Enhanced Channel Assignment Algorithm Enumeration Type CAPABILITY(Capability preferred), QUALITY(Quality preferred), PSRELATIVELY(PS relatively preferred), PSABSOLUTELY(PS absolutely preferred) CAPABILITY, QUALITY, PSRELATIVELY, PSABSOLUTELY None None CAPABILITY Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CHANID Chan ID BSC6900 SET GCELLSBC(Optional)ADD GSMSCB(Mandatory) Channel number of a simple cell broadcast message. This is a key parameter for adding a simple cell broadcast message. You can use "DSP GSMSCB" to query and obtain the value of this parameter. GBFD-113602Simplified Cell Broadcast Interval Type 0~65535 0~65535 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CHANINTERMESALLOW Active CH Interf. Meas.Allowed BSC6900 SET GCELLCHMGAD(Optional) Whether to measure the channel interference during channel assignment. If this parameter is set to NO, the BSC does not measure the channel interference or send an interference indication during channel assignment. If this parameter is set to YES, the BSC measures the channel interference during channel assignment. GBFD-111005Enhanced Channel Assignment Algorithm Enumeration Type NO(No), YES(Yes)NO, YES None None YES Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CHANNELRATECODE Channel Rate Type Decode Expand BSC6900 SET AITFOTHPARA(Optional) When the value of this parameter is YES, if the assignment request message sent by the MSC contains the channel rate type indicating the support of both full and half rates, and contains the speech version indicating the selection of full rate speech version only or half rate speech version only, the BSC decodes the channel rate type into the selection of full rate only or half rate only when decoding the assignment request message. GBFD-111804A Interface Protocol Process Enumeration Type NO(No), YES(Yes)NO, YES None None YES MSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The purpose of setting this parameter is to avoid call connection failure when an MS supporting the full rate channel only requests a half rate channel or an MS supporting the half rate channel only requests a full rate channel. In this way, the BSC can easily interconnect with an MSC of another vendor.
CHECKCOUNT Ping Check Timeout Counts BSC6900 ADD IPPATH(Optional) Ping check timeout counts. The parameter indicates the times of the timeout record failures. None None Interval Type 1~5 1~5 None 5 5 IP path When the value of "PATHCHK" in "ADD IPPATH" is set to ENABLED, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved When the network status is poor, the check count should not be too small. Otherwise, the path state is affected.
CheckingBTSConnection Auto Check of BTS Connection Port BSC6900 SET OTHSOFTPARA(Optional) Whether to enable the BSC to check automatically whether a BTS is connected a proper E1 port in the EIUa. If a BTS is connected to an E1 port configured for another BTS in the EIUa, the BTS cannot be reset automatically after the BTS is initialized. Thus, the data configurations on the BTS side differ from the data configurations on the BSC side. MRFD-210206Tree Topology Enumeration Type NO, YES NO, YES None None YES BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ChkModA ANT_A ALD Current Detection Mode BSC6900 SET BTSRXUBP(Optional) Alarm mode of the ANT_A tributary of an RXU board. There are three alarm modes. Alarm mode 1 has only one type of alarms. The alarm current is fixed and greater than the normal working current. Alarm mode 2 has two types of alarms: warning alarms and critical alarms. The alarm current is fixed and greater than the normal working current. Alarm mode 3 has two types of alarms: warning alarms and critical alarms. The warning alarm current is periodical pulse current, while the critical alarm current is fixed. When the parameter is set to 1, "ANT_AALD Current Minor Alarm Occur Th", "ANT_AALD Current Minor Alarm Clear Th", "AALD Cur-Minor Alarm Over-Cur Duration", and "AALD Cur-Minor Alarm N-Cur Duration" cannot be configured. When the parameter is set to 2, "AALD Cur-Minor Alarm Over-Cur Duration", and "AALD Cur-Minor Alarm N-Cur Duration" cannot be configured. When the parameter is set to 3, "ANT_AALD Current Minor Alarm Occur Th", and "ANT_AALD Current Minor Alarm Clear Th" cannot be configured. GBFD-111202O&M of BTS Enumeration Type MODE1(Mode 1), MODE2(Mode 2), MODE3(Mode 3) MODE1, MODE2, MODE3 None MODE2 MODE2 BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ChkModB ANT_B ALD Current Detection Mode BSC6900 SET BTSRXUBP(Optional) Alarm mode of the ANT_B tributary of an RXU board. There are three alarm modes. Alarm mode 1 has only one type of alarms. The alarm current is fixed and greater than the normal working current. Alarm mode 2 has two types of alarms: warning alarms and critical alarms. The alarm current is fixed and greater than the normal working current. Alarm mode 3 has two types of alarms: warning alarms and critical alarms. The warning alarm current is periodical pulse current, while the critical alarm current is fixed. When the parameter is set to 1, "ANT_B ALD Current Minor Alarm Occur Th", "ANT_B ALD Current Minor Alarm Clear Th", "B ALD Cur-Minor Alarm Over-Cur Duration", and "B ALD Cur-Minor Alarm N-Cur Duration" cannot be configured. When the parameter is set to 2, "B ALD Cur-Minor Alarm Over-Cur Duration", and "B ALD Cur-Minor Alarm N-Cur Duration" cannot be configured. When the parameter is set to 3, "ANT_B ALD Current Minor Alarm Occur Th", and "ANT_B ALD Current Minor Alarm Clear Th" cannot be configured. GBFD-111202O&M of BTS Enumeration Type MODE1(Mode 1), MODE2(Mode 2), MODE3(Mode 3) MODE1, MODE2, MODE3 None MODE2 MODE2 BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CHKN Check Index BSC6900 STR IPCHK(Optional) Detection index. The index is a unique value ranging from 0 to 511 if it is not specified. GBFD-118609IP Fault Detection Based on BFD Interval Type 0~511 0~511 None None None None None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
CHKN Check Index BSC6900 ADD IPPATHBIND(Mandatory) Detection indexGBFD-118609IP Fault Detection Based on BFD Interval Type 0~511 0~511 None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CHKOFFTIMES Check Times for Off BSC6900 SET BTSAIRCON(Optional) Total number of times that the BTS checks whether to switch off the air conditioner GBFD-111202O&M of BTS Interval Type 5~20 5~20 None None 10 BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter is supported only by the BTS3012A and BTS3006A.
CHKONTIMES Check Times for On BSC6900 SET BTSAIRCON(Optional) Total number of times that the BTS checks whether to switch on the air conditioner GBFD-111202O&M of BTS Interval Type 5~20 5~20 None None 10 BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter is supported only by the BTS3012A and BTS3006A.
CHKSUMRX Calculate checksum when receive message BSC6900 ADD SCTPLNK(Optional) Whether to calculate checksum when receiving message. None None Enumeration Type NO(NO), YES(YES) NO, YES None NO NO SCTP linkNone Read & Write Y SCTP link The services are interrupted until the SCTP link is working normally. The checksum mode need the negotiation with the peer. According to the RFC4960, the value should be set to CRC32.
CHKSUMTX Calculate checksum when send message BSC6900 ADD SCTPLNK(Optional) Whether to calculate checksum when sending message. None None Enumeration Type NO(NO), YES(YES) NO, YES None NO NO SCTP linkNone Read & Write Y SCTP link The services are interrupted until the SCTP link is working normally. The checksum mode need the negotiation with the peer. According to the RFC4960, the value should be set to CRC32.
CHKSUMTYPE Checksum arithmetic BSC6900 ADD SCTPLNK(Optional) Checksum arithmetic type. According to the RFC4960, the ALDER32 algorithm is not applicable to the SCTP checksum. The CRC32 is recommended. None None Enumeration Type ALDER32(ALDER32), CRC32(CRC32) ALDER32, CRC32 None CRC32 CRC32 SCTP linkNone Read & Write Y SCTP link The services are interrupted until the SCTP link is working normally. None
CHKTYPE Check type BSC6900 STR IPCHK(Mandatory) Gateway detection type GBFD-118609IP Fault Detection Based on BFD Enumeration Type SBFD, ARP, MBFDSBFD, ARP, MBFD None None None None None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
CHLDURATH Duration Hour BSC6900 STR BTSTST(Mandatory) Duration GBFD-111207BTS Test Function Interval Type 0~12 0~12 h None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CHNNO Channel No. BSC6900 SET BTSCHNFALLBACK(Mandatory) Number of the channel in the TRX MRFD-210301Configuration Management Interval Type 1~7 1~7 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter is supported only by the following types of BTSs: BTS3012, BTS3006C, BTS3012AE, BTS3012 II, and BTS3002E.
CHNNO Channel No. BSC6900 SET TCPLYVOICE(Mandatory) Timeslot for playing sound GBFD-111203O&M of BSC Interval Type 0~169 0~169 None None None Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CHNO Channel No. BSC6900 SET FHO(Mandatory)SET GTRXCHANHOP(Mandatory)SET GTRXCHAN(Mandatory)SET GTRXCHANADMSTAT(Mandatory)STR BTSTST(Mandatory) Number of the channel in the TRX MRFD-210301Configuration Management Interval Type 0~7 0~7 None None None Physical channel None Read & Write Not involved Not involved Not involved None
CHNTSTTYPE Channel Test Type BSC6900 STR BTSTST(Mandatory) Type of channel loopback test GBFD-111207BTS Test Function Enumeration Type TRXRFSELFLOOP(TRX RF Self Loopback Test), BIULOOP(BIU Loopback Test), BTSSPEECHLOOP(BTS Speech Loopback Test), TRXSPEECHLOOP(TRX Speech Loopback Test) TRXRFSELFLOOP, BIULOOP, BTSSPEECHLOOP, TRXSPEECHLOOP None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CHNTYPE Channel Type BSC6900 SET BTSCHNFALLBACK(Mandatory) Channel type of the timeslot on the TRX. The channel type of timeslot 0 must not be set, because the combined BCCH is configured by default. The channel type of other timeslots can be set to full-rate TCH or half-rate TCH. MRFD-210301Configuration Management Enumeration Type FULLTCH(FULLTCH), HALFTCH(HALFTCH) FULLTCH, HALFTCH None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter is supported only by the following types of BTSs: BTS3012, BTS3006C, BTS3012AE, BTS3012 II, and BTS3002E.
ChosenChInAssCmp ChosenCh Send Flag in ASS CMP BSC6900 SET MSGSOFTPARA(Optional) Whether an assignment complete message contains the information element of Chosen Channel GBFD-111804A Interface Protocol Process Enumeration Type NO(No), YES(Yes)NO, YES None None YES MSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The setting of this parameter needs negotiation with the opposite network element MSC.If the MSC supports processing assignment complete messages containing the Chosen Channel, set this parameter to YES; otherwise, set this parameter to NO.
ChosenChInHoPerform ChosenCh Send Flag in HO Perform BSC6900 SET MSGSOFTPARA(Optional) Whether a handover performed message contains the information element of Chosen Channel GBFD-111804A Interface Protocol Process Enumeration Type NO(No), YES(Yes)NO, YES None None YES MSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The setting of this parameter needs negotiation with the opposite network element MSC.If the MSC supports processing handover performed messages containing the Chosen Channel, set this parameter to YES; otherwise, set this parameter to NO.
ChosenChInHoReqAck ChosenCh Send Flag in HO REQ ACK BSC6900 SET MSGSOFTPARA(Optional) Whether an HO REQ ACK message contains the information element of Chosen Channel GBFD-111804A Interface Protocol Process Enumeration Type NO(No), YES(Yes)NO, YES None None YES MSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The setting of this parameter needs negotiation with the opposite network element MSC.If the MSC supports processing HO REQ ACK messages containing the Chosen Channel, set this parameter to YES; otherwise, set this parameter to NO.
ChosenEncrypAlgInCiphCmp ChosenEncrypAlg Send Flag in Cipher CMP BSC6900 SET MSGSOFTPARA(Optional) Whether an encryption complete message contains the information element of Chosen Encryption Algorithm GBFD-111804A Interface Protocol Process Enumeration Type NO(No), YES(Yes)NO, YES None None YES MSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The setting of this parameter needs negotiation with the opposite network element MSC. In this way, the MSC can process encryption complete messages correctly.
ChosenEncrypAlgInHoPerform ChosenEncrypAlg Send Flag in HO Perform BSC6900 SET MSGSOFTPARA(Optional) Whether a handover performed message contains the information element of Chosen Encryption Algorithm GBFD-111804A Interface Protocol Process Enumeration Type NO(No), YES(Yes)NO, YES None None YES MSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The setting of this parameter needs negotiation with the opposite network element MSC. In this way, the MSC can process handover performed messages correctly.
ChosenEncrypAloInAssCmp ChosenEncrypAlo Send Flag in ASS CMP BSC6900 SET MSGSOFTPARA(Optional) Whether an assignment complete message contains the information element of Chosen Encryption Algorithm GBFD-111804A Interface Protocol Process Enumeration Type NO(No), YES(Yes)NO, YES None None YES MSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The setting of this parameter needs negotiation with the opposite network element MSC. In this way, the MSC can process assignment complete messages correctly. An assignment complete message contains the Chosen Encryption Algorithm only when the encryption algorithm used by an MS in two cells changes before and after a direct retry and the value of this parameter is YES.
ChosenEncrypAloInHoReqAck ChosenEncrypAlo Send Flag in HO REQ ACK BSC6900 SET MSGSOFTPARA(Optional) Whether an HO REQ ACK message contains the information element of Chosen Encryption Algorithm GBFD-111804A Interface Protocol Process Enumeration Type NOSENDING(Force NO Sending), SYSTEMOPT(System Optimization), SENDING(Force Sending) NOSENDING, SYSTEMOPT, SENDING None None SYSTEMOPT MSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The setting of this parameter needs negotiation with the opposite network element MSC.SENDING: The HO REQ ACK message contains the Chosen Encryption Algorithm.NOSENDING: The HO REQ ACK message does not contain the Chosen Encryption Algorithm.SYSTEMOPT: If the encryption algorithm used by an MS in two cells changes before and after a handover, the HO REQ ACK message contains the Chosen Encryption Algorithm; otherwise, the message does not.
CHPWRINSUFFALLOWED Channel Assign Allow for Insuff Power BSC6900 SET GCELLCHMGAD(Optional) Whether to allow a multi-density TRX board that uses the dynamic power sharing algorithm to assign channels to assign a channel to an MS when the remaining power on the multi-density TRX board is less than the power required by the MS. If this parameter is set to YES, a multi-density TRX board that uses the dynamic power sharing algorithm to assign channels cannot assign a channel to an MS when the remaining power on the multi-density TRX board is less than the power required by the MS.If this parameter is set to NO, a multi-density TRX board that uses the dynamic power sharing algorithm to assign channels can assign a channel to an MS when the remaining power on the multi-density TRX board is less than the power required by the MS. GBFD-111005Enhanced Channel Assignment Algorithm Enumeration Type NO(No), YES(Yes)NO, YES None None YES Cell This parameter is valid only when "QTRUPWRSHARE" is not set to NONE. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CHREQCSMAXMSGNUMINPERIOD Max CS CHAN REQ Num In Period BSC6900 SET BSCFCPARA(Optional) Maximum number of allowable CS domain channel request messages within the value of "CHAN REQ Statistical Period" GBFD-111705GSM Flow Control Interval Type 10~800 10~800 None None 100 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CHREQPSAVGMSGNUMINPERIOD Average PS CHAN REQ Num BSC6900 SET BSCFCPARA(Optional) Average number of allowable PS domain channel request messages within the value of "CHAN REQ Statistical Period" GBFD-111705GSM Flow Control Interval Type 10~800 10~800 None None 200 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CHREQSTATPERIOD CHAN REQ Statistical Period BSC6900 SET BSCFCPARA(Optional) Statistic period of the arrival rate of channel request messages. Within the preset value of this parameter, the BSC counts the number of channel request messages. Once the current total number of times exceeds the value of the allowable number of channel request messages of CPU0 within the statistic period, the BSC begins to discard subsequent channel request messages until the current time reaches a new "CHAN REQ Statistical Period". GBFD-111705GSM Flow Control Interval Type 100~600000 100~600000 ms None 1000 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The smaller the value of this parameter is, the more sensitively the BSC controls the arrival rate of channel request messages, and vice versa.
CHTYPE Channel Type BSC6900 SET GTRXCHAN(Optional) Type and function of the channelCombined BCCH+7TCHMain BCCH+SDCCH/8+6TCHMain BCCH+2SDCCH/8+5TCHMain BCCH+SDCCH/8+extended BCCH (BCH)+5TCHMain BCCH+SDCCH/8+extended BCCH (BCH)+TCH+extended BCCH (BCH)+3TCHThe BCCHs in a cell need to be configured according to the number of channels in the cell and the paging capacity in the location area.The main and combined BCCHs shall always be configured in timeslot 0. An extended BCCH can be configured only in timeslot 2, 4, or 6. If an extended BCCH is configured, the CCCH parameter in the system message data needs to be configured accordingly. For example, if an extended BCCH is configured in timeslot 2, the CCCH parameter in the system message data needs to be configured as two uncombined CCCHs.To enable cell broadcast in a cell, add a CBCH to the cell during the radio channel configuration. In the case of SDCCH/8 cell broadcast, set this parameter to SDCCH_CBCH. You can change a TCH into SDCCH+CBCH or the original SDCCH into SDCCH+CBCH. In the case of S MRFD-210301Configuration Management Enumeration Type TCHFR(TCH Full Rate), TCHHR(TCH Half Rate), SDCCH8(SDCCH8), MBCCH(Main BCCH), CBCCH(Combined BCCH), BCH(BCH), BCCH_CBCH(BCCH+CBCH), SDCCH_CBCH(SDCCH+CBCH), PBCCH_PDTCH(PBCCH+PDTCH), PCCCH_PDTCH(PCCCH+PDTCH), PDTCH(PDTCH), DPDCH(Dynamic PDCH) TCHFR, TCHHR, SDCCH8, MBCCH, CBCCH, BCH, BCCH_CBCH, SDCCH_CBCH, PBCCH_PDTCH, PCCCH_PDTCH, PDTCH, DPDCH None None None Physical channel None Read & Write Y Channel Less than 1 minute None
CI Cell CI BSC6900 ADD GCELL(Mandatory)ADD GEXT2GCELL(Mandatory)ADD GEXT3GCELL(Mandatory)SET FHO(Mandatory)ADD GCELLQUICKSETUP(Mandatory)ADD BTSAUTOPLAN(Mandatory)SET BTSAUTOPLANCFG(Optional) Identity code of a cell.A cell is a wireless coverage area identified by a base station identity code and a global cell identification MRFD-210301Configuration Management Interval Type 0~65535 0~65535 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CI1 Cell CI BSC6900 SET BTSAUTOPLANCFG(Optional) Cell identity code. The cell is a radio coverage area that is identified by the BTS identity code and global cell identity code. MRFD-210301Configuration Management Interval Type 0~65535 0~65535 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CIC CIC BSC6900 BLK ACIC(Mandatory) It indicates the A interface CIC. When operation mode is set to OPC index, DPC group index, BSC ID, or CIC, the parameter is mandatory. The parameter supports multiple values. GBFD-111803A Interface Circuit Management Interval Type 0~65535 0~65535 None None None E1/T1 linkWhen the value of "OPMODE" of "BLK ACIC" is BYCICVALUE, the value of CIC needs to be set. Read & Write N (No impact on the UE in idle mode) Not involved Not involved 1. The block of A interface must be configured. 2. If A over IP is configured, the configuration does not support the operation.
CIC CIC BSC6900 BLK PBCIC(Mandatory) It indicates the Pb interface CIC.2. If the search object mode is set to search by the specified No., the parameter is mandatory.The parameter supports multiple values. GBFD-111203O&M of BSC Interval Type 0~65535 0~65535 None None None None None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
CicPoolInAssFail CIC Pool Send Flag in ASS Fail BSC6900 SET MSGSOFTPARA(Optional) Whether an assignment failure message contains the information element of Circuit Pool GBFD-111804A Interface Protocol Process Enumeration Type NO(No), YES(Yes)NO, YES None None YES MSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The setting of this parameter needs negotiation with the opposite network element MSC. In this way, the MSC can process assignment complete messages correctly.
CicPoolInHoFail CIC Pool Send Flag in HO Fail BSC6900 SET MSGSOFTPARA(Optional) Whether an HO FAIL message contains the the information element of Circuit Pool GBFD-111804A Interface Protocol Process Enumeration Type NO(No), YES(Yes)NO, YES None None YES MSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The setting of this parameter needs negotiation with the opposite network element MSC. In this way, the MSC can process HO FAIL messages correctly.
CicPoolListInAssFail CIC Pool List Send Flag in ASS Fail BSC6900 SET MSGSOFTPARA(Optional) Whether an assignment failure message contains the the information element of Circuit Pool List GBFD-111804A Interface Protocol Process Enumeration Type NOTSENDING(Not sending), SENDINGPRO(sending according to protocol), SENDING(unconditionally sending) NOTSENDING, SENDINGPRO, SENDING None None NOTSENDING MSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The setting of this parameter needs negotiation with the opposite network element MSC. In this way, the MSC can process assignment failure messages correctly.NOSENDING: The assignment failure message does not contain the Circuit Pool List.SENDINGPRO: If the cause value of assignment failure is "Circuit pool mismatch" or "Switch circuit pool", the assignment failure message contains the Circuit Pool List; otherwise, the message does not.SENDING: The assignment failure message contains the Circuit Pool List without restriction.
CicPoolListInHoFail CIC Pool List Send Flag in HO Fail BSC6900 SET MSGSOFTPARA(Optional) Whether an HO FAIL message contains the the information element of Circuit Pool List GBFD-111804A Interface Protocol Process Enumeration Type NOTSENDING(Not sending), SENDINGPRO(sending according to protocol), SENDING(unconditionally sending) NOTSENDING, SENDINGPRO, SENDING None None NOTSENDING MSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The setting of this parameter needs negotiation with the opposite network element MSC. In this way, the MSC can process HO FAIL messages correctly.
CicPoolSendFlagInAssCmp CIC Pool Send Flag in ASS CMP BSC6900 SET MSGSOFTPARA(Optional) Whether an assignment complete message contains the information element of Circuit Pool GBFD-111804A Interface Protocol Process Enumeration Type NO(No), YES(Yes)NO, YES None None YES MSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The setting of this parameter needs negotiation with the opposite network element MSC.If the MSC does not support process assignment complete messages containing the Circuit Pool, the value YES of this parameter makes no sense.
CicPoolSendFlagInHoAck CIC Pool Send FlagIn HO REQ ACK BSC6900 SET MSGSOFTPARA(Optional) Whether an HO REQ ACK message contains the information element of Circuit Pool GBFD-111804A Interface Protocol Process Enumeration Type NO(No), YES(Yes)NO, YES None None YES MSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The setting of this parameter needs negotiation with the opposite network element MSC.If the MSC does not support process assignment complete messages containing the Circuit Pool, the value YES of this parameter makes no sense.
CIR Bandwidth [64kbps] BSC6900 ADD IPLOGICPORT(Mandatory) Bandwidth of the logical port None None Interval Type 1~1000 64~64000, step:64 kbit/s None None IP logical port None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CIRESTVALUE C/I Estimate Value BSC6900 SET GCELLCHMGAD(Optional) This parameter specifies the estimated carrier-to-interference ratio of a new call. It is used for the Huawei power control algorithm III to calculate the power required for the call. None None Interval Type 0~22 0~22 dB None 22 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CIUSLOTNO Slot No. BSC6900 ADD DXXCONNECT(Mandatory) Number of the slot for the BSC board that connects to the DXX GBFD-111202O&M of BTS Interval Type 0~27 0~27 None None None BSC6900None Read & Write Y BTS Less than 5 minutes None
CIUSUBRACKNO Subrack No. BSC6900 ADD DXXCONNECT(Mandatory) Number of the subrack for the BSC board that connects to the DXX GBFD-111202O&M of BTS Interval Type 0~11 0~11 None None None BSC6900None Read & Write Y BTS Less than 5 minutes None
CLASS11DTM Support Class11 DTM BSC6900 SET GCELLGPRS(Optional) Whether the cell supports the MS with the DTM multi-timeslot capability of class 11. GBFD-119403Class11 DTM Enumeration Type UNSUPPORT(Not Support), SUPPORT(Support) UNSUPPORT, SUPPORT None None None Cell This parameter is valid only when "GPRS" is set to SupportAsInnPcu and "SUPPORTDTM" is set to SUPPORT. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CLASSMARKQUERY Classmark Enquiry With 3G Request BSC6900 SET OTHSOFTPARA(Optional) Whether to enable the BSC to include the 3G classmark information element in the Classmark Request message that the BSC forwards from the MSC to an MS GBFD-110501Call Control Enumeration Type NO(No), YES(Yes)NO, YES None None NO BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CLEARTHD Error clear threshold BSC6900 ADD MPGRP(Optional) Error clear threshold. GBFD-118611GBFD-118622 Abis IP over E1/T1A IP over E1/T1 Enumeration Type ERR_PFM_1E6(RECOVERY:1E-6), ERR_PFM_5E6(RECOVERY:5E-6), ERR_PFM_1E5(RECOVERY:1E-5), ERR_PFM_5E5(RECOVERY:5E-5), ERR_PFM_1E4(RECOVERY:1E-4), ERR_PFM_5E4(RECOVERY:5E-4), ERR_PFM_1E3(RECOVERY:1E-3) ERR_PFM_1E6, ERR_PFM_5E6, ERR_PFM_1E5, ERR_PFM_5E5, ERR_PFM_1E4, ERR_PFM_5E4, ERR_PFM_1E3 None None ERR_PFM_5E6 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CLKMOD Clock Mode BSC6900 SET BTSCLKPARA(Mandatory) Clock mode GBFD-111202O&M of BTS Enumeration Type INCLK(Internal Clock), BSCCLK(Trace BSC Clock), EXCLK(External Synchro Clock), IPCLK(IP Clock), TRANSCLK(Trace Trans Clock), GPSCLK(Trace GPS Clock), UMCLK(Um Clock), MOMTCLK(Multimode Other Mode Transmission Clock) INCLK, BSCCLK, EXCLK, IPCLK, TRANSCLK, GPSCLK, UMCLK, MOMTCLK None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CLKPRTTYPE Clock Protocol Type BSC6900 SET BTSIPCLKPARA(Optional) Type of the clock protocol for the IP clock server GBFD-111202O&M of BTS Enumeration Type HW_DEFINED(Huawei User-defined), PTP(PTP Protocol) HW_DEFINED, PTP None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ClkType Clock Type BSC6900 SET BTSCLK(Mandatory) Clock mode of the BTS.If this parameter is set to INT_CLK, the BTS does not track any external clock. The internal high precision clock works in free-run mode.If this parameter is set to TRCBSC_CLK, the BTS tracks the clock signals received from the BSC.If this parameter is set to EXCLK, the BTS tracks the clock signals received from the external input clock.If this parameter is set to IP_TIME, the BTS shakes hands through the IP network with the IP clock server for synchronization.If this parameter is set to IP_TRANSFER, the BTS extracts the clock from an E1 when there is not an IP clock after the BTS upgrades the transmission mode from E1 transmission to IP transmission.If this parameter is set to TRCGPS_CLK, the BTS extracts the clock through the DGPS from the GPS.If this parameter is set to UM_CLK, the BTS keeps pace with the signals broadcast on the downlink main BCCH of a neighboring BTS.If this parameter is set to MOTHER_CLK, the multimode BTS(GSM) keeps pace with the signals that the other mod MRFD-210501BTS/NodeB Clock Enumeration Type INT_CLK(Internal Clock), TRCBSC_CLK(Trace BSC Clock), EXTSYN_CLK(External Sync clock), IP_TIME(IP Clock), IP_TRANSFER(Trace Transport Clock), TRCGPS_CLK(Trace GPS Clock), UM_CLK(Um Clock), MOTHER_CLK(Multimode other mode transmission clock) INT_CLK, TRCBSC_CLK, EXTSYN_CLK, IP_TIME, IP_TRANSFER, TRCGPS_CLK, UM_CLK, MOTHER_CLK None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ClrDelay Clear Command Delay Time BSC6900 SET BTSTHEFTALM(Optional) Delay for which the BTS waits to run the burglar alarm clearance command after reporting the burglar alarm GBFD-111202O&M of BTS Interval Type 0~255 0~255 s None None BTS This parameter is valid only when "AntiTheftAllow" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
clrflg Alarm Cleared Flag BSC6900 EXP ALMLOG(Optional)STAALMLOG(Optional) Whether the alarm to be queried is cleared. You can select "cleared" or "uncleared", or both of them. By default, both of them are selected. MRFD-210304Faulty Management Bit Field Type cleared, unclearedcleared, uncleared None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ClrInterval Clear Command Time Interval BSC6900 SET BTSTHEFTALM(Optional) Interval at which the BTS runs the burglar alarm clearance command automatically GBFD-111202O&M of BTS Interval Type 0~255 0~255 s None None BTS This parameter is valid only when "AntiTheftAllow" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CMD Command Name BSC6900 EXP LOG(Optional) Name of the command to be queried. You can select one or more commands. GBFD-111203MRFD-210305 O&M of BSCSecurity Management String Type None 1~200 characters None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CMD Command Name BSC6900 ADD CCG(Mandatory) You can select one or more commands. GBFD-111203MRFD-210305 O&M of BSCSecurity Management String Type None 0~128 characters None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CMDCODE CmdCode BSC6900 SET LOGCFG(Mandatory) CmdCode MRFD-210304Faulty Management Interval Type 0~65535 {0~65535} None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CMDSEQ Command Sequence BSC6900 ADD SUBCMD(Mandatory) Sequence number of the command string of the scheduled subtask. GBFD-111203O&M of BSC Interval Type 0~19 0~19 None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CN Cabinet No. BSC6900 ADD CAB(Mandatory) Number of the cabinet MRFD-210301Configuration Management Interval Type 1~3 1~3 None None None None None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
CN Cabinet No. BSC6900 SWP BTSRING(Optional)SWP BTSOMLLINK(Optional)ADD TRXBIND2PHYBRD(Optional)SET BTSFMUABP(Optional)SET BTSAPMUBP(Optional)SET BTSDATUBP(Optional)SET BTSDEMUBP(Optional)SET BTSDHEUBP(Optional)SET BTSUSCUBP(Optional)SET BTSCABPARA(Mandatory)SET BTSPOWERTYPE(Mandatory)SET BTSRXUBP(Optional)ADD BTSRXU2LOCGRP(Mandatory)ADD BTSBINDLOCGRP(Mandatory)ADD BTSBRD(Optional)ADD BTSCABINET(Mandatory)ADD BTSRXUBRD(Optional)SET BTSENVALMPORT(Optional)ADD BTSOBJALMSHLD(Mandatory) Number of the cabinet GBFD-111202O&M of BTS Interval Type 0~62 0~62 None None None BTS The value range of this parameter varies with BTS type. Different types of BTSs support a different number of cabinets. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CN Cabinet No. BSC6900 ADD BTSBFD(Optional)ADD BTSIPRTBIND(Optional) Number of the cabinet GBFD-118609IP Fault Detection Based on BFD Interval Type 0~62 0~62 None 0 None BTS The value range of this parameter varies with BTS type. Different types of BTSs support a different number of cabinets. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CN Port Cabinet No. BSC6900 ADD BTSSFPMODE(Optional)SET BTSFORBIDTS(Optional)SET BTSOMLTS(Optional)ADD BTSTOPCONFIG(Optional)SET BTSETHPORT(Optional)ADD BTSPPPLNK(Optional)ADD BTSMPLNK(Optional)ADD BTSETHMA(Optional)ADD BTSETHLCMEP(Optional) Number of the cabinet where the port is located GBFD-111202O&M of BTS Interval Type 0~62 0~62 None None None BSC6900None Read & Write Y BTS Less than 5 minutes None
CN Cabinet No. BSC6900 LOD RETANTCFG(Optional)SET BTSANTANGLE(Optional)SET BTSCLKPARA(Optional)SET BTSCAVFRQ(Optional)SET BTSPMUDEF(Optional)SET BTSTMA(Optional)SET RETANTENB(Optional)STR BTSBATTTST(Optional)STR RETANTSCAN(Optional)STR TRANSPERFTST(Optional)SWP BTSBRD(Optional)SET BTSENVALM(Optional)CHG BTSPTUSHKTM(Optional) Number of the cabinet GBFD-111202O&M of BTS Interval Type 0~62 0~62 None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CNFAULTDELAY CN Fault Delay BSC6900 SET GBSCREDGRP(Optional) Time delay of the detection on core network interface failure. Within the preset value of this parameter, the BSC continuously detects core network interface failures and then releases the management right of service objects. GBFD-113725BSC Node Redundancy Interval Type 1~60 1~60 s 30 30 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CNID MSC ID BSC6900 ADD GCNNODE(Mandatory) Used to uniquely identify an MSC GBFD-117401MSC Pool Interval Type 0~4095 0~4095 None None None MSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CNID SGSN Node ID BSC6900 ADD NSE(Mandatory)ADD SGSNNODE(Mandatory)ADD NRISGSNMAP(Mandatory) Identifies a node of SGSN with the operator name uniquely. GBFD-119701SGSN Pool Interval Type 0~4095 0~4095 None None None NSE None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CNMNGMODE Resource Management Mode BSC6900 ADD ADJMAP(Mandatory) Resource management mode. When the interface type is IUB, the value can be set to SHARE or EXCLUSIVE. When the interface type is IUR, IUCS, or IUPS, the value can be set to SHARE only. None None Enumeration Type SHARE(SHARE), EXCLUSIVE(EXCLUSIVE) SHARE, EXCLUSIVE None None None Adjacent node None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
CNNODEIDX CN Node Index BSC6900 ADD NRIMSCMAP(Mandatory)SET MSGSOFTPARA(Mandatory) SET AITFOTHPARA(Mandatory)SET BSCAITFTMR(Mandatory)ADD GCNNODE(Mandatory) Node index of an MSC GBFD-117401MSC Pool Interval Type 0~31 0~31 None None None BSC6900None Read & Write Not involved Not involved Not involved The value of this parameter cannot be changed.
CNOPERATORINDEX Operator Index BSC6900 CMP LICENSE(Optional) Index of the operator MRFD-210403License Management Interval Type 0~3 0~3 None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CNOPINDEX CN Operator index BSC6900 ADD RSCGRP(Mandatory)ADD ADJMAP(Mandatory) Operator index of the resource group None None Interval Type 0~3 0~3 None None None Transmission resource group When "RSCMNGMODE" in "ADD RSCGRP" is set to EXCLUSIVE, this parameter is valid. Read & Write Not involved Not involved Not involved The parameter cannot be modified.
CNOPINDEX CN operator index BSC6900 ADD IPLOGICPORT(Optional) Index of the operator None None Interval Type 0~3 0~3 None None None BSC6900None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
CNSTATEPOLICYFORGROUP CN State Policy For Group BSC6900 SET GBSCREDGRP(Optional) Policy of the BSC for judging whether the interface status of the core network is normal. If the value is NONE, the BSC does not change the service management right. If the value is AINTFBLOCK, the BSC releases the service management right when detecting disconnection at the A interface. GBFD-113725BSC Node Redundancy Enumeration Type NONE(None), AINTFBLOCK(AInterf Block) NONE, AINTFBLOCK None NONE None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
cnt Records to Return BSC6900 EXP ALMLOG(Optional) Number of returned alarm records. By default, 64 records can be returned in each query. MRFD-210304Faulty Management Interval Type 1~150000 1~150000 None 64 None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CNT Cabinet Type BSC6900 SET BTSBAT(Mandatory) Type of the cabinet. The slot and subrack arrangements in a cabinet vary according to the cabinet type. GBFD-111202O&M of BTS Enumeration Type BTS3002C, BTS3012A, BTS3006A BTS3002C, BTS3012A, BTS3006A None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CNT Cabinet Type BSC6900 SET BTSDPMUBP(Mandatory) Type of the BTS cabinet where the DMPU is installed GBFD-111202O&M of BTS Enumeration Type BTS3012(BTS3012), BTS3012AE(BTS3012AE), BTS3006C(BTS3006C), BTS3012_II(BTS3012 II), BTS3002E(BTS3002E), DBS3900_GSM(DBS3900 GSM), BTS3900_GSM(BTS3900 GSM), BTS3900A_GSM(BTS3900A GSM), DBS3036(DBS3036), BTS3036(BTS3036), BTS3036A(BTS3036A) BTS3012, BTS3012AE, BTS3006C, BTS3012_II, BTS3002E, DBS3900_GSM, BTS3900_GSM, BTS3900A_GSM, DBS3036, BTS3036, BTS3036A None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CNTL Counts Limit[Items] BSC6900 SET LOGLIMIT(Optional) Maximum number of records allowed in the operation log GBFD-111203MRFD-210305 O&M of BSCSecurity Management Interval Type 10000~50000 10000~50000 None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CNTRISTHRD Upper count threshold of raised fault BSC6900 SET ALMBLKPARA(Optional) Assume that this threshold is not 0. When the accumulated number of alarm blink times exceeds the threshold, the alarm is reported. For querying the alarm blink measurement period, see "LST ALMBLKSW". For setting the alarm blink measurement period, see "SET ALMBLKSW". MRFD-210304Faulty Management Interval Type 0~250 0~250 None None None None 1. If you set "Upper count threshold of raised fault" and "Lower count threshold of raised fault" to "0", the accumulated number of blink times for the alarm is counted but not reported.2. If "Upper count threshold of raised fault" is not "0", the value of "Lower count threshold of raised fault" cannot be "0" and you must ensure that "Upper count threshold of raised fault" is greater than "Lower count threshold of raised fault".3. When "Upper count threshold of raised fault" is not "0" and "Alarm switch of blinking filter" and "Switch of stat blinking alarm" are "ENABLE", you cannot set "Alarm blink threshold" to "0". Otherwise, blink statistics of the alarm is not performed. Read & Write N (No impact on the UE in idle mode) Not involved Not involved 1. If you set "Upper count threshold of raised fault" and "Lower count threshold of raised fault" to "0", the accumulated number of blink times for the alarm is counted but not reported.2. If "Upper count threshold of raised fault" is not "0", the value of "Lower count threshold of raised fault" cannot be "0" and you must ensure that "Upper count threshold of raised fault" is greater than "Lower count threshold of raised fault".3. When "Upper count threshold of raised fault" is not "0" and "Alarm switch of blinking filter" and "Switch of stat blinking alarm" are "ENABLE", you cannot set "Alarm blink threshold" to "0". Otherwise, blink statistics of the alarm is not performed.
CNTSTLTHRD Lower count threshold of raised fault BSC6900 SET ALMBLKPARA(Optional) Assume that this threshold is not 0. When the number of alarm blink times is smaller than the threshold, the alarm is reported. For querying the alarm blink measurement period, see "LST ALMBLKSW". For setting the alarm blink measurement period, see "SET ALMBLKSW". MRFD-210304Faulty Management Interval Type 0~250 0~250 None None None None 1. If you set "Upper count threshold of raised fault" and "Lower count threshold of raised fault" to "0", the accumulated number of blink times for the alarm is counted but not reported.2. If "Lower count threshold of raised fault" is not 0, the value of "Upper count threshold of raised fault" cannot be 0 and you must ensure that "Lower count threshold of raised fault" is smaller than "Upper count threshold of raised fault".3. When "Upper count threshold of raised fault" is not "0" and "Alarm switch of blinking filter" and "Switch of stat blinking alarm" are "ENABLE", you cannot set "Alarm blink threshold" to "0". Otherwise, blink statistics of the alarm is not performed. Read & Write N (No impact on the UE in idle mode) Not involved Not involved 1. If you set "Upper count threshold of raised fault" and "Lower count threshold of raised fault" to "0", the accumulated number of blink times for the alarm is counted but not reported.2. If "Lower count threshold of raised fault" is not 0, the value of "Upper count threshold of raised fault" cannot be 0 and you must ensure that "Lower count threshold of raised fault" is smaller than "Upper count threshold of raised fault".3. When "Upper count threshold of raised fault" is not "0" and "Alarm switch of blinking filter" and "Switch of stat blinking alarm" are "ENABLE", you cannot set "Alarm blink threshold" to "0". Otherwise, blink statistics of the alarm is not performed.
COBSCMSCADJEN Co-BSC/MSC Adj BSC6900 SET GCELLHOBASIC(Optional) Whether to adjust the candidate cell queue to give priority to intra-BSC/MSC handover GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Enumeration Type NO(No), YES(Yes)NO, YES None None YES Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CODE Code BSC6900 ADD GSMSCB(Mandatory) Number of a simple cell broadcast message. You can run "DSP GSMSCB" to query and obtain the information.The value of this parameter cannot be 0.This parameter, "Geography Scope", and "Update" uniquely decide a cell broadcast message. GBFD-113602Simplified Cell Broadcast Interval Type 1~1023 1~1023 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
COLDSET Refrigeration Equipment BSC6900 SET BTSOUTPUT(Optional) Whether to start the refrigeration equipment of the BTS.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. GBFD-111202O&M of BTS Enumeration Type INACTIVE(Inactive), ACTIVE(Active) INACTIVE, ACTIVE None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
COLTYPE Collection Type BSC6900 COL SYNCINFO(Mandatory) Whether to collect offset information by the BTS or cell. GBFD-118201Soft-Synchronized Network Enumeration Type BYSITE(By Site), BYCELL(By Cell) BYSITE, BYCELL None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None.
COMBINERLOSS Combiner Loss BSC6900 SET GCELLPWRBASIC(Optional) Combined loss used to estimate the downlink power during assignment GBFD-117602Active Power Control Interval Type 0~100 0~100, step:0.1 dB None None Cell This parameter is valid only when "PWRBCDALLOWD" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
COMMACC Common Access Control Class BSC6900 SET GCELLCCBASIC(Optional) Level of common access control, used for load control, allowing or forbidding the access of some users of common access levels GBFD-111003Radio Common Channel Management Bit Field Type L0_FORBID, L1_FORBID, L2_FORBID, L3_FORBID, L4_FORBID, L5_FORBID, L6_FORBID, L7_FORBID, L8_FORBID, L9_FORBID L0_FORBID, L1_FORBID, L2_FORBID, L3_FORBID, L4_FORBID, L5_FORBID, L6_FORBID, L7_FORBID, L8_FORBID, L9_FORBID None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
COMMONSWITCH Preserved Alarm Switch BSC6900 SET BTSFMUABP(Optional) This parameter consists of four bits, each of which indicates whether the corresponding alarm is enabled or not. The bit value 0 indicates that the alarm is enabled, and the bit value 1 indicates that the alarm is disabled.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. MRFD-210304Faulty Management Bit Field Type NO1_DISABLE, NO2_DISABLE, NO3_DISABLE, NO4_DISABLE NO1_DISABLE, NO2_DISABLE, NO3_DISABLE, NO4_DISABLE None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
COMMONSWITCHER Alarm Disabled Configuration BSC6900 SET BTSDHEUBP(Optional) Whether to enable the dry contact alarm. The value of this parameter consists of four bits from left to right, each of which indicating whether the corresponding alarm is enabled. "0" indicates that the alarm is enabled, and "1" indicates that the alarm is disabled. The DTCU board supports four routes of Boolean alarms: NO1_DISABLE, NO2_DISABLE, NO3_DISABLE, and NO4_DISABLE. GBFD-111202O&M of BTS Bit Field Type NO1_DISABLE, NO2_DISABLE, NO3_DISABLE, NO4_DISABLE NO1_DISABLE, NO2_DISABLE, NO3_DISABLE, NO4_DISABLE None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
COMMONSWITCHERLEVEL Preserved Alarm Valid Level CFG BSC6900 SET BTSFMUABP(Optional) This parameter consists of four bits. Each bit determines whether the one-way Boolean alarm is triggered by low level or high level. "0" indicates that the alarm is triggered by high level, and "1" indicates that the alarm is triggered by low level.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. MRFD-210304Faulty Management Bit Field Type NO1_DISABLE, NO2_DISABLE, NO3_DISABLE, NO4_DISABLE NO1_DISABLE, NO2_DISABLE, NO3_DISABLE, NO4_DISABLE None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
Complicacy Password Complicacy BSC6900 SET PWDPOLICY(Optional) Complicacy of the password MRFD-210305Security Management Bit Field Type LOWERCASE, UPPERCASE, DIGIT LOWERCASE, UPPERCASE, DIGIT None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
COMPRS COMPRS BSC6900 SET BTSBWPARA(Optional) BTS compress rate. GBFD-111202O&M of BTS Interval Type 1~100 1~100 None 100 None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
COMSC Co-MSC BSC6900 ADD GEXT2GCELL(Optional) Whether the BSC that controls the external cell and the local BSC belong to the same MSC GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Enumeration Type NO(No), YES(Yes)NO, YES None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CONBSCBTSIDTYPE Connect BSC BTS Index type BSC6900 ADD BTSABISHDLCPATH(Mandatory) Index type of the BTS connect to BSC GBFD-111202O&M of BTS Enumeration Type BYNAME(By Name), BYID(By Index) BYNAME, BYID None None None BTS None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
CONGCLRTHD0 Recover threshold of queue 0 [ms] BSC6900 ADD PORTFLOWCTRLPARA(Optional) If the duration for buffering the data in queue 0 is less than or equals to the value of this parameter, flow control is canceled. For the flow control adopting the ATM, this parameter indicates the recovery threshold for congestion in the CBR queue. None None Interval Type 10~150 10~150 ms 15 IP:15; ATM:20 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter can be added and modified. It cannot be deleted.
CONGCLRTHD1 Recover threshold of queue 1 [ms] BSC6900 ADD PORTFLOWCTRLPARA(Optional) If the duration for buffering the data in queue 1 is less than or equals to the value of this parameter, flow control is canceled. For the flow control adopting the ATM, this parameter indicates the recovery threshold for congestion in the RTVBR queue. None None Interval Type 10~150 10~150 ms 15 IP:15; ATM:20 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter can be added and modified. It cannot be deleted.
CONGCLRTHD2 Recover threshold of queue 2 [ms] BSC6900 ADD PORTFLOWCTRLPARA(Optional) If the duration for buffering the data in queue 2 is less than or equals to the value of this parameter, flow control is canceled. For the flow control adopting the ATM, this parameter indicates the recovery threshold for congestion in the NRTVBR queue. None None Interval Type 10~150 10~150 ms 15 IP:15; ATM:20 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter can be added and modified. It cannot be deleted.
CONGCLRTHD3 Recover threshold of queue 3 [ms] BSC6900 ADD PORTFLOWCTRLPARA(Optional) If the duration for buffering the data in queue 3 is less than or equals to the value of this parameter, flow control is canceled. For the flow control adopting the ATM, this parameter indicates the recovery threshold for congestion in the UBR queue. None None Interval Type 10~150 10~150 ms 15 IP:15; ATM:25 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter can be added and modified. It cannot be deleted.
CONGCLRTHD4 Recover threshold of queue 4 [ms] BSC6900 ADD PORTFLOWCTRLPARA(Optional) If the duration for buffering the data in queue 4 is less than or equals to the value of this parameter, flow control is canceled. For the flow control adopting the ATM, this parameter indicates the recovery threshold for congestion in the UBR+ queue. None None Interval Type 10~150 10~150 ms 25 25 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter can be added and modified. It cannot be deleted.
CONGCLRTHD5 Recover threshold of queue 5 [ms] BSC6900 ADD PORTFLOWCTRLPARA(Optional) If the duration for buffering the data in queue 5 is less than or equals to the value of this parameter, flow control is canceled. None None Interval Type 10~150 10~150 ms 25 25 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter can be added and modified. It cannot be deleted.
CONGTHD0 Congestion threshold of queue 0 [ms] BSC6900 ADD PORTFLOWCTRLPARA(Optional) If the duration for buffering the data in queue 0 is more than or equals to the value of this parameter, flow control is triggered. For the flow control adopting the ATM, this parameter indicates the threshold for congestion in the CBR queue. None None Interval Type 10~150 10~150 ms 25 IP:25; ATM:30 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter can be added and modified. It cannot be deleted.
CONGTHD1 Congestion threshold of queue 1 [ms] BSC6900 ADD PORTFLOWCTRLPARA(Optional) If the duration for buffering the data in queue 1 is more than or equals to the value of this parameter, flow control is triggered. For the flow control adopting the ATM, this parameter indicates the threshold for congestion in the RTVBR queue. None None Interval Type 10~150 10~150 ms 25 IP:25; ATM:30 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter can be added and modified. It cannot be deleted.
CONGTHD2 Congestion threshold of queue 2 [ms] BSC6900 ADD PORTFLOWCTRLPARA(Optional) If the duration for buffering the data in queue 2 is more than or equals to the value of this parameter, flow control is triggered. For the flow control adopting the ATM, this parameter indicates the threshold for congestion in the NRTVBR queue. None None Interval Type 10~150 10~150 ms 25 IP:25; ATM:30 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter can be added and modified. It cannot be deleted.
CONGTHD3 Congestion threshold of queue 3 [ms] BSC6900 ADD PORTFLOWCTRLPARA(Optional) If the duration for buffering the data in queue 3 is more than or equals to or equals to the value of this parameter, flow control is triggered. For the flow control adopting the ATM, this parameter indicates the threshold for congestion in the UBR queue. None None Interval Type 10~150 10~150 ms 25 IP:25; ATM:50 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter can be added and modified. It cannot be deleted.
CONGTHD4 Congestion threshold of queue 4 [ms] BSC6900 ADD PORTFLOWCTRLPARA(Optional) If the duration for buffering the data in queue 4 is more than or equals to the value of this parameter, flow control is triggered. For the flow control adopting the ATM, this parameter indicates the threshold for congestion in the UBR+ queue. None None Interval Type 10~150 10~150 ms 50 50 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter can be added and modified. It cannot be deleted.
CONGTHD5 Congestion threshold of queue 5 [ms] BSC6900 ADD PORTFLOWCTRLPARA(Optional) If the duration for buffering the data in queue 5 is more than or equals to the value of this parameter, flow control is triggered. None None Interval Type 10~150 10~150 ms 50 50 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter can be added and modified. It cannot be deleted.
CONHOEN Concentric Circles HO Allowed BSC6900 SET GCELLHOBASIC(Optional) Whether to enable the concentric cell handover algorithm. The concentric cell handover helps to achieve wide coverage in the underlaid subcell and aggressive frequency reuse in the overlaid subcell and to improve the system capacity and conversation quality. The concentric cell handover can be classified into two types: handover from the underlaid subcell to the overlaid subcell and handover from the overlaid subcell to the underlaid subcell. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Enumeration Type NO(No), YES(Yes)NO, YES None None NO Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CONNECTPORTNO Connect Port No. BSC6900 ADD DXXCONNECT(Mandatory) Number of the port for the object that connects to the DXX MRFD-210206Tree Topology Interval Type 0~335 0~335 None None None BSC6900None Read & Write Y BTS Less than 5 minutes None
CONNECTTYPE Connect Type BSC6900 ADD GCBSADDR(Mandatory) Mode of the connection between the BSC and the CBC GBFD-113601Short Message Service Cell Broadcast (TS23) Enumeration Type XPU(XPU Board), IP_INT(IP Int Board) XPU, IP_INT None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CONNPWR Connect power monitoring board BSC6900 ADD SUBRACK(Optional) Whether to connect the power monitoring board MRFD-210301Configuration Management Enumeration Type NO(NO), YES(YES) NO, YES None NO NO None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CONNTYPE Connection Type BSC6900 SET CONNTYPE(Mandatory) Type of the connection between the NE and EMS or LMT. The connection can be a plain connection or SSL encryption connection. GBFD-111203MRFD-210305 O&M of BSCSecurity Management Enumeration Type ALL(ALL Type), ONLY_SSL(Only SSL Connection) ALL, ONLY_SSL None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CONNTYPE Connection Type BSC6900 ADD GIURGCONN(Mandatory) Whether the Iur-g common connection is established between the BSC and a co-BSC6900 RNC or an external RNC. MRFD-211402MBSC Load Balancing Enumeration Type INNER(Internal RNC), EXTERNAL(External RNC) INNER, EXTERNAL None None None BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CONTHOMININTV Min Interval for Consecutive Hos BSC6900 SET GCELLHOCTRL(Optional) Minimum interval between the two consecutive handover decisions of an MS. The BSC cannot make a handover decision during the minimum interval.To avoid frequent handover events in the cell, the BSC starts a timer after delivering a handover command to an MS. The BSC allows the MS to make a second handover decision only after the timer expires. This parameter specifies the duration of the timer. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 0~60 0~60 s None 4 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CONTINTV Interval for Consecutive HO Jud. BSC6900 SET GCELLHOAD(Optional) The twice intra-cell handover events during this interval are considered consecutive handover events. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 1~200 1~200 s None 6 Cell This parameter, together with "BANTIME", limits the handover frequency in the cell. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CONTPING Continue ping or not BSC6900 PING IP(Optional) Whether to perform the PING operation continuously. When the continuous PING operation is performed, the system sends the PING packets to the specified IP address. You can stop the PING operation by using CTRL + Q. None None Enumeration Type NO(NO), YES(YES) NO, YES None NO NO Ethernet port None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
Count Send PKT Count BSC6900 PING MAC(Optional)PING BTSCFM(Optional) Transmitted packets None None Interval Type 1~28 1~28 None 5 5 Ethernet port None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
CPAGECTHD Call page control threshold BSC6900 SET FCCPUTHD(Optional) CPU usage threshold for call paging control. When the average CPU usage of sliding windows reaches or exceeds the threshold, call paging flow control is triggered. This parameter is valid only when "Board Class" is "XPU". WRFD-040100Flow Control Interval Type 30~100 30~100 per cent None 90 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CPAGERTHD Call page restore threshold BSC6900 SET FCCPUTHD(Optional) CPU usage threshold for recovery from call paging control. When the average CPU usage of smooth windows is lower than the threshold, call paging flow control is stopped. This parameter is valid only when "Board Class" is "XPU". WRFD-040100Flow Control Interval Type 30~100 30~100 per cent None 80 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CPS Allow Dynamic shutdown TRX BSC6900 SET GTRXDEV(Optional) Whether to allow the BSC to switch off the power amplifier of the TRX dynamically according to the traffic GBFD-111602TRX Power Amplifier Intelligent Shutdown Enumeration Type NO(No), YES(Yes)NO, YES None None None TRX This parameter is valid only when "BSCDynSwitchTrxPAAllow" in "SET BSCDSTPA" and "DYNOpenTrxPower" in "SET GCELLBASICPARA" are set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter cannot be set to YES for the TRX that carries the main BCCH.
CPUN CPU NO BSC6900 ADD GCBSADDR(Mandatory) CPU number on a board MRFD-210301Configuration Management Interval Type 0~7 0~7 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CRC4CHK CRC4 Check Switch BSC6900 SET BTSCRC4(Mandatory) Whether to enable to the BTS to support CRC4 check GBFD-111202O&M of BTS Enumeration Type OFF(Off), ON(On), NOTSUPPORT(Not Support) OFF, ON, NOTSUPPORT None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter is not supported by the BTS3001C and BTS3001CP.
CRH Cell Reselect Hysteresis Parameters BSC6900 SET GCELLIDLEBASIC(Optional) Cell reselection hysteresis. This is one of the parameters used for deciding whether to reselect cells in different location areas. This parameter can avoid the increase of network signaling traffic due to frequent location update and reduce the risk of losing paging messages. GBFD-110402Basic Cell Re-selection Enumeration Type 0dB, 2dB, 4dB, 6dB, 8dB, 10dB, 12dB, 14dB 0dB, 2dB, 4dB, 6dB, 8dB, 10dB, 12dB, 14dB dB None 6dB Cell None Read & Write N (Impact on the UE in idle mode) Not involved Not involved None
CRL Certificate Revocation List File Name BSC6900 SET CERTFILE(Mandatory) Name of the certificate revocation list file MRFD-210305Security Management String Type None 0~200 characters None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CRLEnableSta Certificate Revocation List File State BSC6900 SET CERTFILE(Optional) Whether to enable the certificate revocation list DISABLE: indicating that the certificate revocation list is disabledENABLE: indicating that the certificate revocation list is enabled MRFD-210305Security Management Enumeration Type DISABLE(Disable), ENABLE(Enable) DISABLE, ENABLE None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CRMSGRESENDINT Channel Release Resend Interval BSC6900 SET GCELLGSMR(Optional) Time interval for the BTS resending a channel release message GBFD-510301GBFD-510302 Public Voice Group Call ServicePublic Voice Broadcast Service Interval Type 1~255 1~255, step: 10 ms None 10 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CRMSGRESENDNUM Channel Release Resend Number BSC6900 SET GCELLGSMR(Optional) Number of times of the BTS resending a channel release message GBFD-510301GBFD-510302 Public Voice Group Call ServicePublic Voice Broadcast Service Interval Type 1~255 1~255 None None 3 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CRO Cell reselect offset BSC6900 SET GCELLIDLEBASIC(Optional) Cell reselection offset (CRO), indicating a correction of the C2.Proper setting of this parameter can reduce the number of handover times, helpful for assigning an MS to a better cell. In a special case that the PT is 31, the larger the CRO value is, the lower the possibility of handing over an MS to the cell.Generally, do not set the CRO to a value larger than 25 dB. The CRO with a too large value will cause uncertain states in a network. The CRO values of the cells with different priorities in a network are almost the same. Refer to GSM Rec. 05.08 and GSM Rec. 04.08. The setting of this parameter affects only the MSs supporting the protocol of GSM Phase 2 or a later version. GBFD-110402Basic Cell Re-selection Interval Type 0~63 0~63, step: 2 dB None 0 Cell None Read & Write N (Impact on the UE in idle mode) Not involved Not involved The settings of RXLEV-ACCESS-MIN and CRO should guarantee that cells with same priority have the same cell reselect offset.
CROCALTMTHRD Cross Call Detect Time Threshold BSC6900 SET BSCBASIC(Optional) Threshold of the time for crosstalk detection. Within the threshold, if the call flag continuously appearing in the code stream is different from the one saved in a transcoder (TC) or a BTS, the TC or the BTS considers that a crosstalk occurs and sends a message to the BSC. Upon receiving such a message, the BSC host board records in a log the information about the current call, including the information about the Abis interface, Ater interface, BTS, cell, TRX, channel, and TC. GBFD-111203O&M of BSC Interval Type 1~255 1~255 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CROSSIPFLAG Cross IP address available flag BSC6900 ADD SCTPLNK(Optional) The field indicates whether the cross-connect path is available. None None Enumeration Type UNAVAILABLE(UNAVAILABLE), AVAILABLE(AVAILABLE) UNAVAILABLE, AVAILABLE None UNAVAILABLEUNAVAILABLE SCTP linkNone Read & Write N (No impact on the UE in idle mode) Not involved Not involved The parameter is related to practical networking.
CSCONVDL UMTS R99 CS conversational service downlink factor BSC6900 ADD TRMFACTOR(Optional) WCDMA R99 CS conversational service downlink factor None None Interval Type 0~100 0~100 per cent 100 100 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node that is configured with the factor table. After the successful modification, the parameter takes effect in the following two cases:1. New access subscriber. 2. Bandwidth modification of the existing subscriber
CSCONVPRIPATH R99 CS conversational primary path BSC6900 ADD TRMMAP(Optional) R99 CS conversational service primary path None None Enumeration Type CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF None None When the interface type is Iub, transmission type is ATM or dual stack, the parameter is RT_VBR; transimssion type is IP or Hybird IP, the parameter is AF43.When the interface type is Iur, transmission type is ATM, the parameter is RT_VBR; transimssion type is IP, the parameter is AF43.When the interface type is Iu-CS, transmission type is ATM, the parameter is RT_VBR; transimssion type is IP, the parameter is AF43. BSC6900When the value of "ITFT" in "ADD TRMMAP" is set to IUB or IUR or IUCS, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node configured with the TRMMAP. After the successful modification, it is valid in the case of the new access of a subscriber and the bandwidth modification of an existing subscriber.
CSCONVSECPATH R99 CS conversational secondary path BSC6900 ADD TRMMAP(Optional) R99 CS conversational service secondary path None None Enumeration Type CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF, NULL CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF, NULL None None When the interface type is Iub, transmission type is ATM or IP, the parameter is NULL; transimssion type is dual stack, the parameter is AF43; transimssion type is Hybird IP, the parameter is LQAF43.When the interface type is Iur, transmission type is ATM or IP, the parameter is NULL.When the interface type is Iu-CS, transmission type is ATM or IP, the parameter is NULL. BSC6900When the value of "ITFT" in "ADD TRMMAP" is set to IUB or IUR, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node configured with the TRMMAP. After the successful modification, it is valid in the case of the new access of a subscriber and the bandwidth modification of an existing subscriber.
CSCONVUL UMTS R99 CS conversational service uplink factor BSC6900 ADD TRMFACTOR(Optional) WCDMA R99 CS conversational service uplink factor None None Interval Type 0~100 0~100 per cent 100 100 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node that is configured with the factor table. After the successful modification, the parameter takes effect in the following two cases:1. New access subscriber. 2. Bandwidth modification of the existing subscriber
CSDATADL GSM CS data service downlink factor BSC6900 ADD TRMFACTOR(Optional) GSM CS data service downlink factor None None Interval Type 0~100 0~100 per cent 100 100 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node that is configured with the factor table. After the successful modification, the parameter takes effect in the following two cases:1. New access subscriber. 2. Bandwidth modification of the existing subscriber
CSDATAPATH CS data path BSC6900 ADD TRMMAP(Optional) CS data path None None Enumeration Type BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF None None When the transmission type is IP, the parameter is AF43. BSC6900When the value of "ITFT" in "ADD TRMMAP" is set to A or ABIS, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node configured with the TRMMAP. After the successful modification, it is valid in the case of the new access of a subscriber and the bandwidth modification of an existing subscriber.
CSDATAPRI CS data priority BSC6900 ADD TRMMAP(Optional) CS data priorityNone None Interval Type 0~7 0~7 None None When the interface type is Abis and transmission type is HDLC, the parameter is 0. BSC6900When the value of "ITFT" in "ADD TRMMAP" is set to ABIS, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node configured with the TRMMAP. After the successful modification, it is valid in the case of the new access of a subscriber and the bandwidth modification of an existing subscriber.
CSDATAUL GSM CS data service uplink factor BSC6900 ADD TRMFACTOR(Optional) GSM CS data service uplink factor None None Interval Type 0~100 0~100 per cent 100 100 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node that is configured with the factor table. After the successful modification, the parameter takes effect in the following two cases:1. New access subscriber. 2. Bandwidth modification of the existing subscriber
CSDSP CS Data Service PRI BSC6900 ADD GCELL(Optional) Priority of the CS data service GBFD-111705GSM Flow Control Interval Type 0~7 0~7 None 5 5 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The larger the value of this parameter, the higher the proportion of discarded messages during congestion. Therefore, the priority value of a more important service must be less than that of a less important service.
CSSTRMDL UMTS R99 CS streaming service downlink factor BSC6900 ADD TRMFACTOR(Optional) WCDMA R99 CS streaming service downlink factor None None Interval Type 0~100 0~100 per cent 100 100 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node that is configured with the factor table. After the successful modification, the parameter takes effect in the following two cases:1. New access subscriber. 2. Bandwidth modification of the existing subscriber
CSSTRMPRIPATH R99 CS streaming primary path BSC6900 ADD TRMMAP(Optional) R99 CS streaming service bearer primary path None None Enumeration Type CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF None None When the interface type is Iub, transmission type is ATM or dual stack, the parameter is RT_VBR; transimssion type is IP or Hybird IP, the parameter is AF43.When the interface type is Iur, transmission type is ATM, the parameter is RT_VBR; transimssion type is IP, the parameter is AF43.When the interface type is Iu-CS, transmission type is ATM, the parameter is RT_VBR; transimssion type is IP, the parameter is AF43. BSC6900When the value of "ITFT" in "ADD TRMMAP" is set to IUB or IUR or IUCS, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node configured with the TRMMAP. After the successful modification, it is valid in the case of the new access of a subscriber and the bandwidth modification of an existing subscriber.
CSSTRMSECPATH R99 CS streaming secondary path BSC6900 ADD TRMMAP(Optional) R99 CS streaming service bearer secondary path None None Enumeration Type CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF, NULL CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF, NULL None None When the interface type is Iub, transmission type is ATM or IP, the parameter is NULL; transimssion type is dual stack, the parameter is AF43; transimssion type is Hybird IP, the parameter is LQAF43.When the interface type is Iur, transmission type is ATM or IP, the parameter is NULL.When the interface type is Iu-CS, transmission type is ATM or IP, the parameter is NULL. BSC6900When the value of "ITFT" in "ADD TRMMAP" is set to IUB or IUR, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node configured with the TRMMAP. After the successful modification, it is valid in the case of the new access of a subscriber and the bandwidth modification of an existing subscriber.
CSSTRMUL UMTS R99 CS streaming service uplink factor BSC6900 ADD TRMFACTOR(Optional) WCDMA R99 CS streaming service uplink factor None None Interval Type 0~100 0~100 per cent 100 100 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node that is configured with the factor table. After the successful modification, the parameter takes effect in the following two cases:1. New access subscriber. 2. Bandwidth modification of the existing subscriber
CSTARTTHD Congestion Start Threshold BSC6900 SET GTRXFC(Optional) Threshold for starting LAPD link congestion control. This parameter cannot be set too high. If this parameter is set too high, the signaling link may be congested before congestion control is started. The congestion start and end thresholds cannot be set too low. If they are set too low, congestion control may be started frequently on the signaling link. GBFD-111705GSM Flow Control Interval Type 30~100 30~100 per cent None 90 TRX None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The setting of this parameter must be greater than "CENDTHD".
CSVOICEDL GSM CS voice service downlink factor BSC6900 ADD TRMFACTOR(Optional) GSM CS voice service downlink factor None None Interval Type 0~100 0~100 per cent 50 50 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node that is configured with the factor table. After the successful modification, the parameter takes effect in the following two cases:1. New access subscriber. 2. Bandwidth modification of the existing subscriber
CSVOICEPATH CS voice path BSC6900 ADD TRMMAP(Optional) CS voice path None None Enumeration Type BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF None None When the transmission type is A, the parameter is EF. BSC6900When the value of "ITFT" in "ADD TRMMAP" is set to A or ABIS, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node configured with the TRMMAP. After the successful modification, it is valid in the case of the new access of a subscriber and the bandwidth modification of an existing subscriber.
CSVOICEPRI CS voice priority BSC6900 ADD TRMMAP(Optional) CS voice priority None None Interval Type 0~7 0~7 None None When the interface type is Abis and transmission type is HDLC, the parameter is 0. BSC6900When the value of "ITFT" in "ADD TRMMAP" is set to ABIS, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node configured with the TRMMAP. After the successful modification, it is valid in the case of the new access of a subscriber and the bandwidth modification of an existing subscriber.
CSVOICEUL GSM CS voice service uplink factor BSC6900 ADD TRMFACTOR(Optional) GSM CS voice service uplink factor None None Interval Type 0~100 0~100 per cent 50 50 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node that is configured with the factor table. After the successful modification, the parameter takes effect in the following two cases:1. New access subscriber. 2. Bandwidth modification of the existing subscriber
CSVSP CS Voice Service PRI BSC6900 ADD GCELL(Optional) Priority of a speech service in the CS domain. The parameter is used for BSC flow control. GBFD-111705GSM Flow Control Interval Type 0~7 0~7 None 3 3 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The larger the value of this parameter, the higher the proportion of discarded messages during congestion. Therefore, the priority value of a more important service must be less than that of a less important service.
CT1 Timer alignment ready BSC6900 ADD MTP3LNK(Optional) Timer alignment ready. None None Interval Type 40000~50000 40000~50000 ms 45000 45000 MTP3 linkNone Read & Write Y BSC6900 Less than 5 minutes None
CT2 Timer not aligned BSC6900 ADD MTP3LNK(Optional) Timer not aligned. None None Interval Type 5000~150000 5000~150000 ms 30000 30000 MTP3 linkNone Read & Write Y BSC6900 Less than 5 minutes None
CT3 Timer aligned BSC6900 ADD MTP3LNK(Optional) Timer aligned. None None Interval Type 1000~2000 1000~2000 ms 1300 1300 MTP3 linkNone Read & Write Y BSC6900 Less than 5 minutes None
CT4E Timer emergency proving BSC6900 ADD MTP3LNK(Optional) Timer emergency proving. None None Interval Type 400~600 400~600 ms 500 500 MTP3 linkNone Read & Write Y BSC6900 Less than 5 minutes None
CT4N Timer normal proving BSC6900 ADD MTP3LNK(Optional) Timer normal proving. None None Interval Type 7500~9500 7500~9500 ms 8200 8200 MTP3 linkNone Read & Write Y BSC6900 Less than 5 minutes None
CT5 Timer sending SIB BSC6900 ADD MTP3LNK(Optional) Timer sending SIB. None None Interval Type 80~120 80~120 ms 100 100 MTP3 linkNone Read & Write Y BSC6900 Less than 5 minutes None
CT6 Timer remote congestion BSC6900 ADD MTP3LNK(Optional) Timer remote congestion. None None Interval Type 3000~6000 3000~6000 ms 5000 5000 MTP3 linkNone Read & Write Y BSC6900 Less than 5 minutes None
CT7 Timer excessive delay of acknowledgement BSC6900 ADD MTP3LNK(Optional) Timer excessive delay acknowledgement. None None Interval Type 500~2000 500~2000 ms 1500 1500 MTP3 linkNone Read & Write Y BSC6900 Less than 5 minutes None
CT9 Timer interval of resending FISU BSC6900 ADD MTP3LNK(Optional) Timer interval of resending FISU. None None Interval Type 1~100 1~100 ms 100 100 MTP3 linkNone Read & Write Y BSC6900 Less than 5 minutes None
CTHD Critical threshold BSC6900 SET FCCPUTHD(Optional) Critical threshold of CPU usage. When the CPU usage in "Fast judgement window" reaches or exceeds the threshold, all active flow control functions are implemented. Otherwise, the corresponding flow control mechanism is used. WRFD-040100Flow Control Interval Type 30~100 30~100 per cent None 95 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CTHD Critical threshold BSC6900 SET FCMSGQTHD(Optional) Critical threshold of packet queue usage. When the packet queue usage reaches or exceeds the threshold, all active flow control functions are implemented. WRFD-040100Flow Control Interval Type 30~100 30~100 per cent None 85 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CTRBSCDPC Control BSC DPC BSC6900 ADD AISSCFG(Mandatory) DPC of the control BSC. GBFD-118201Soft-Synchronized Network Interval Type 1~16777215 1~16777215 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None.
CTRLACKTYPE Control Acknowledge Type BSC6900 SET GCELLPSBASE(Optional) Format of the control acknowledge message of the MS. Four access bursts are used to obtain timing advance without sending polling message; RLC/MAC control block is used to obtain timing advance after sending polling message. GBFD-114101GPRS Enumeration Type 4BURST(4Burst), RLC/MAC(RLC/MAC) 4BURST, RLC/MAC None None 4BURST Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CTRLFLAG Control Flag BSC6900 SET BTSLOADCTRL(Mandatory) Control Flag GBFD-111202O&M of BTS Enumeration Type NO(Cancel Control Flag), YES(Set Control Flag) YES, NO None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CTRLPORTCN ControlPort Cabinet No. BSC6900 ADD BTSRETANT(Mandatory) Number of the cabinet which controls RET antenna. MRFD-210602Remote Electrical Tilt Interval Type 0~62 0~62 None None None BTS The value range of this parameter varies with BTS type. Different types of BTSs support a different number of cabinets. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CTRLPORTNO ControlPort No. BSC6900 ADD BTSRETANT(Mandatory) ControlPort No. of RET antenna. The number of RET antenna which connect to same feed tributary cannot more than 6.For GATM boards, the valid value ranges from 0 to 5. For RXU boards, the valid value ranges from 0 to 2. MRFD-210602Remote Electrical Tilt Interval Type 0~5 0~5 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CTRLPORTSN ControlPort Slot No. BSC6900 ADD BTSRETANT(Mandatory) Number of the slot where the board controlling the RET antenna is located. For SRAN BTSs, the valid value ranges from 0 to 5. For non-SRAN BTSs, the valid value ranges from 0 to 23. MRFD-210602Remote Electrical Tilt Interval Type 0~23 0~23 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CTRLPORTSRN ControlPort Subrack No. BSC6900 ADD BTSRETANT(Mandatory) Number of the subrack where the BTS board is located MRFD-210602Remote Electrical Tilt Interval Type 0~254 0~254 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
CTRLSLOT Slot No. BSC6900 ADD RSCGRP(Mandatory) Slot No. of the MPU for the centralized management of the resources None None Interval Type 0,2,4,8,10,12,14,16,18,20,22,24,26 0, 2, 4, 8, 10, 12, 14, 16, 18, 20, 22, 24, 26 None None None Transmission resource group None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
CTRLSN CTRL SN BSC6900 SET BTSCTRL(Mandatory) Number of the BSC slot where the XPU of the control plane is located GBFD-111202O&M of BTS Interval Type 0~255 0~255 None None None BTS None Read & Write Y BTS Less than 5 minutes If this parameter of an activated BTS is modified, the entire BTS chain is reset.
CTRLSRN CTRL SRN BSC6900 SET BTSCTRL(Mandatory) Number of the BSC subrack where the XPU of the control plane is located GBFD-111202O&M of BTS Interval Type 0~255 0~255 None None None BTS None Read & Write Y BTS Less than 5 minutes If this parameter of an activated BTS is modified, the entire BTS chain is reset.
CTRLSW CM Control Enable Switch BSC6900 SET CMCTRLSW(Mandatory) Configuration rollback control switch that is used to specify whether to support the configuration rollback function. MRFD-210301Configuration Management Enumeration Type ON, OFF ON, OFF None None ON BSC6900None Read & Write Not involved Not involved Not involved None
CurChannelInHoRqd HO_RQD Current Channel BSC6900 SET MSGSOFTPARA(Optional) Whether an HO_RQD message contains the Current Channel GBFD-111804A Interface Protocol Process Enumeration Type NO(No), YES(Yes)NO, YES None None NO MSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The setting of this parameter needs negotiation with the opposite network element MSC. In this way, the MSC can process HO RQD messages correctly.
CVer C-Version No. BSC6900 SET BTSAUTODLDACTINFO(Mandatory) C-version number of the BTS software GBFD-111202O&M of BTS Interval Type 0~99 0~99 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DATAQUAFLTLEN Filter Length for TCH Qual BSC6900 SET GCELLHOFITPEN(Optional) Number of measurement reports sampled for averaging the signal quality on a speech/data channel. Averaging the signal quality in multiple measurement reports helps to avoid a sharp signal quality drop due to Rayleigh fading and to ensure the comprehensiveness of a handover decision. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 1~31 0~31, step:480 for TCH and 470 for SDCCH ms None 6 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DATASTRFLTLEN Filter Length for TCH Level BSC6900 SET GCELLHOFITPEN(Optional) Number of measurement reports sampled for averaging the signal strength on a speech/data channel. Averaging the signal strength in multiple measurement reports helps to avoid a sharp signal level drop due to Rayleigh fading and to ensure the comprehensiveness of a handover decision. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 1~31 0~31, step:480 for TCH and 470 for SDCCH ms None 6 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DATATRAFFSET Data Service Allowed BSC6900 SET GCELLOTHEXT(Optional) Data service supported by the BSC. You can set this parameter according to actual requirements. GBFD-110204G3 Fax (TS61, TS62) Bit Field Type NT14_5K~0 NT12K~1 NT6K~2 T14_4K~3 T9_6K~4 T4_8K~5 T2_4K~6 T1_2K~7 T600_BITS~8 T1200_75 NT14_5K, NT12K, NT6K, T14_4K, T9_6K, T4_8K, T2_4K, T1_2K, T600_BITS, T1200_75 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DATE Date Limit BSC6900 ADD OP(Optional)Whether to limit the operation date of the operator GBFD-111203MRFD-210305 O&M of BSCSecurity Management Enumeration Type NOLIMIT(No Limit), LIMIT(Limit) NOLIMIT, LIMIT None NOLIMIT No Limit RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
5/5/2014
Confidential Information of Huawei.
No Spreading without Permission
Page6of42
226347869.xls.ms_office Security Level:
DATE Date BSC6900 SET TIME(Optional) Date GBFD-111203O&M of BSC Compound Type YEAR, MONTH, DAY 2000-1-1~2099-12-31None None None RNC None Read & Write Not involved Not involved Not Involved None
DateRangeIndex Prohib DynShutdown TRX Pwr DateRangeIdx BSC6900 ADD BSCDSTPADATE(Mandatory) Unique number of the date range during which to disable the BSC from shutting down the power amplifier of a TRX dynamically GBFD-111602TRX Power Amplifier Intelligent Shutdown Interval Type 1~12 1~12 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
Day Day BSC6900 SET BTSAUTODLDACTINFO(Mandatory) Date when the TMU board software is released GBFD-111202O&M of BTS Interval Type 1~31 1~31 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DBD Dead Band BSC6900 SET BTSDHEUBP(Optional) Temperature error allowed when the temperature control system adjusts the temperature.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. GBFD-111202O&M of BTS Interval Type 0~30 0~30 degree Celsius None 2 BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DBFREQBCCHIUO BCCH IUO of Double Frequency Cell BSC6900 ADD GCELL(Mandatory) Whether the primary BCCH is configured on the inner or extra part of an intelligent underlay-overlay (IUO) cell GBFD-114501Co-BCCH Cell Enumeration Type Inner(Inner), Extra(Extra) Inner, Extra None None If the coverage area in the underlaid subcell is large and tight frequency reuse is used in the overlaid subcell, the recommended value is Inner.If the coverage areas in the overlaid and underlaid subcells are similar and tight frequency reuse is used on the BCCH, the recommended value is Extra. Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DBLFREQADJCID Same Group Cell Index BSC6900 ADD GCELL(Mandatory) Index of a same group cell in an enhanced dual band network GBFD-114402Enhanced Dual-Band Network Interval Type 0~2047 0~2047 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DBLFREQADJCNAME Same Group Cell Name BSC6900 ADD GCELL(Mandatory) Name of a same group cell in an enhanced dual band network GBFD-114402Enhanced Dual-Band Network String Type None 1~64 characters None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DBLFREQADJIDTYPE Same Group Cell Index Type BSC6900 ADD GCELL(Mandatory) Index type of a same group cell in an enhanced dual band network GBFD-114402Enhanced Dual-Band Network Enumeration Type BYNAME(By Name), BYID(By Index) BYNAME, BYID None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DCVLTHD DC Voltage Lower Threshold BSC6900 SET BTSAPMUBP(Optional) DC voltage alarm lower threshold. When the busbar output voltage is lower than the value of this parameter, an alarm indicating the abnormal busbar voltage is reported.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. GBFD-111202O&M of BTS Interval Type 350~556 43.3~55.5 (step: 0.1) V None If "Power System Type" is "SC48200", the recommended value is "470". For Power System Type, the recommended value is "450". BTS The value of this parameter must be greater than "Battery power-off voltage", lower than "DC overvoltage alarm threshold", and at least two volts lower than "Float charging voltage". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DCVOLALARMH DC Overvoltage Alarm Threshold BSC6900 SET BTSDPMUBP(Optional) The BTS reports an alarm if the DC voltage exceeds the value of this parameter.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. MRFD-210304Faulty Management Interval Type 580~600 58.0~60.0 (step: 0.1) V None 580 BTS The value of this parameter must be greater than "DC undervoltage alarm threshold" and at least two volts greater than "Even charging voltage". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DCVOLALARML DC Undervoltage Alarm Threshold BSC6900 SET BTSDPMUBP(Optional) The BTS reports an alarm if the DC voltage is lower than the value of this parameter.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. MRFD-210304Faulty Management Interval Type 433~555 43.3~55.5 (step: 0.1) V None 450 BTS The value of this parameter must be greater than "Battery power-off voltage", lower than "DC overvoltage alarm threshold", and at least three volts lower than "Float charging voltage". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DCVUTHD DC Voltage Upper Threshold BSC6900 SET BTSAPMUBP(Optional) DC voltage alarm upper threshold. When the busbar output voltage is higher than the value of this parameter, an alarm indicating the abnormal busbar voltage is reported.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. GBFD-111202O&M of BTS Interval Type 580~600 58~60 (step: 0.1) V None 580 BTS The value of this parameter must be greater than "DC Voltage Lower Threshold" and at least one volt greater than "Even charging voltage". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DEBUGSUBNET Debugging Subnet No. BSC6900 SET SUBNET(Optional) debugging subnet No. in a BSC. None None Interval Type 1~126,128~223 1~126, 128~223 None None None BSC6900None Read & Write Not involved Not involved Not involved None
DefaultDynPdchPreTranNum Number of Dynamic Channel Pre-Converted BSC6900 SET GCELLPSCHM(Optional) This parameter specifies the default pre-converted PDCHs in the dynamic transferable channel pool. GBFD-113101PDCH Dynamic Adjustment Interval Type 0~32 0~32 None None 0 Cell None Read & Write Y Cell Less than 5 minutes None
DELAYSENDRFCHREL T3111 BSC6900 SET GCELLTMR(Optional) Timer for delaying a connection release. This parameter is used for delaying the channel deactivation after the active signaling link is broken. The purpose is to reserve some time for the disconnection that may be repeated. After receiving a REL IND message sent by the BTS, the BSC starts the timer. When the timer expires, the BSC stops the timer and sends the BTS an RF CHAN REL message. GBFD-111004Radio Dedicated Channel Management Interval Type 500~60000 500~60000 ms None 1000 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DENO Destination entity No. BSC6900 ADD M3DE(Mandatory)ADD M3RT(Mandatory)ADD M3LKS(Mandatory) Destination entity No. of identifying a unique entity. None None Interval Type 0~182 0~182 None None None BSC6900None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
DESC Description BSC6900 ADD OP(Optional)Description of the operator account GBFD-111203MRFD-210305 O&M of BSCSecurity Management String Type None 1~110 characters None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DESTEALSET Anti-theft Equipment BSC6900 SET BTSOUTPUT(Optional) Whether to start the anti-theft equipment of the BTS.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. GBFD-111202O&M of BTS Enumeration Type INACTIVE(Inactive), ACTIVE(Active) INACTIVE, ACTIVE None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DESTIP Destination IP address BSC6900 PING IP(Mandatory) Destination IP address None None IP Address Type None 0.0.0.0~255.255.255.255 None None None Ethernet port None Read & Write N (No impact on the UE in idle mode) Not involved Not involved When running this command, the source IP address and the destination IP address cannot be the local IP address and the peer IP address configured for the IPPATH.
DESTIP Destination IP address BSC6900 TRC IPADDR(Mandatory) Destination IP address None None IP Address Type None 0.0.0.0~255.255.255.255 None None None BSC6900None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
DESTIP Destination IP address BSC6900 ADD IPRTBIND(Mandatory) Destination IP address None None IP Address Type None 0.0.0.0~255.255.255.255 None None None None None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
DESTMEPID RMEP ID BSC6900 PING MAC(Mandatory)TRC MAC(Mandatory)PING BTSCFM(Mandatory)TRC BTSCFM(Mandatory) Identifies a maintenance point in the maintenance group None None Interval Type 1~400 1~400 None None None Ethernet port None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
DESTNODE Transport Link Type BSC6900 ADD BTSAUTOPLAN(Mandatory) Type of the object the BTS is connected to GBFD-510701Compact BTS Automatic Configuration and Planning Enumeration Type BSC, BTS BSC, BTS None None None BTS None Read & Write Y BTS Less than 5 minutes None
DESTNODE Dest Node Type BSC6900 ADD BTSCONNECT(Mandatory) Type of the object the BTS is connected to. Value range: BTS, BSC, and DXX GBFD-111202O&M of BTS Enumeration Type BTS, BSC, DXX, OTHER BTS, BSC, DXX, OTHER None None None BTS None Read & Write Y BTS Less than 5 minutes This parameter can be modified only when the BTS is deactivated.
DESTSN Peer Slot No. BSC6900 ADD GIURGCONN(Mandatory) Slot No. of the subsystem where the Iur-g common connection is established to the co-BSC6900 RNC MRFD-211402MBSC Load Balancing Interval Type 0~27 {0~27} None None None BSC This parameter is required when the Connection Type is Internal RNC. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DESTSRN Peer Subrack No. BSC6900 ADD GIURGCONN(Mandatory) Subrack No. of the subsystem where the Iur-g common connection is established to the co-BSC6900 RNC MRFD-211402MBSC Load Balancing Interval Type 0~11 {0~11} None None None BSC This parameter is required when the Connection Type is Internal RNC. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DESTSSN Peer Subsystem No. BSC6900 ADD GIURGCONN(Mandatory) No. of the subsystem where the Iur-g common connection is established to the co-BSC6900 RNC MRFD-211402MBSC Load Balancing Interval Type 0~7 {0~7} None None None BSC This parameter is required when the Connection Type is Internal RNC. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DESTTRXID Destination Main BCCH TRX ID BSC6900 MOV BCCH(Mandatory) ID of the TRX that carries the destination main BCCH MRFD-210301Configuration Management Interval Type 0~3071 0~3071 None None None Cell None Read & Write Y Cell Less than 1 minute None
DETECTMULT Detect Period BSC6900 ADD BTSBFD(Optional) Maximum number of periods in which the local end does not receive BFD packets from the peer end. If the number of periods in which the local end does not receive BFD packets from the peer end reaches this parameter, the BTS reports a BFD session fail. GBFD-118609IP Fault Detection Based on BFD Interval Type 3~10 3~10 None 3 3 Current BFD session None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DETECTSWITCH Switch for Abis Timeslot Detection BSC6900 SET BTSABISTROP(Mandatory) Switch for Abis Timeslot Detection None None Enumeration Type OFF(OFF), ON(ON) OFF, ON None None OFF BSC6900None Read & Write Not involved Not involved Not involved None
DEVICENAME Deviced Name BSC6900 ADD BTSRETANT(Mandatory) Name of the RET antenna MRFD-210602Remote Electrical Tilt String Type None 0~50 characters None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DEVICENO Device No. BSC6900 ADD BTSRETANT(Mandatory) Number of the RET antenna. MRFD-210602Remote Electrical Tilt Interval Type 0~35 0~35 None None None BTS None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
DEVIP Borrowed device IP address BSC6900 ADD PPPLNK(Mandatory)ADD MPGRP(Mandatory) Borrowed device IP address. GBFD-118611GBFD-118622 Abis IP over E1/T1A IP over E1/T1 IP Address Type None 0.0.0.0~255.255.255.255 None None None BSC6900None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
DEVTYPE Device IP Address Type BSC6900 ADD DEVIP(Mandatory) Device IP Address Type None None Enumeration Type LOGIC_IP(Logical IP Address), IPOA_CLIENT_IP(IPOA Client IP Address) LOGIC_IP, IPOA_CLIENT_IP None None None BSC6900None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
DF DL UARFCN BSC6900 ADD GEXT3GCELL(Optional)SET GCELLHOFDDBA2(Mandatory)SET GCELLHOTDDBA2(Mandatory) Downlink frequency of the external 3G cell GBFD-114301GBFD-114302 GSM/WCDMA InteroperabilityGSM/TD-SCDMA Interoperability Interval Type 0~16383 0~16383 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DFCBSN DFCB Board SN BSC6900 SET BTSDFCUBP(Optional) Number of the slot where the DFCB is installed GBFD-111202O&M of BTS Interval Type 0~23 0~23 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DFCBSRN DFCB Board SRN BSC6900 SET BTSDFCUBP(Optional) Number of the subrack where the DFCB is installed GBFD-111202O&M of BTS Interval Type 0~254 0~254 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DFDPC Default DPC BSC6900 ADD GCNNODE(Optional) Default destination signaling point code (DPC). YES: When the MSC Pool function is not enabled, all the calls connected to this BSC can access only the MSC identified by this DPC.NO: When the MSC Pool function is not enabled, all the calls under this BSC are not connected on the MSC identified by this DPC. If the MSC Pool function is enabled, this parameter is invalid. GBFD-117401MSC Pool Enumeration Type NO(Not Default DPC), YES(Default DPC) NO, YES None NO NO MSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DFTPORTSWT The Type of FTPS Server Command Port BSC6900 SET FTPSSRV(Mandatory) Whether to use the customized portDEFAULTPORT: indicating that the FTP server uses the default port 21 as a command port and port 20 as a data port to provide FTP servicesCUSTOMPORT: indicating that the FTP server uses the customized port to provide FTP services GBFD-111203MRFD-210305 O&M of BSCSecurity Management Enumeration Type DEFAULTPORT(Default 21 Port), CUSTOMPORT(Custom Port) DEFAULTPORT, CUSTOMPORT None None DEFAULTPORT RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DHCPRLYGATEWAYIP DHCP Relay Gateway IP Address BSC6900 ADD DHCPRLY(Mandatory) This parameter indicates the IP Address of DHCP Relay Gateway. None None IP Address Type None 0.0.0.0~255.255.255.255 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DHCPRLYID DHCP Relay ID BSC6900 ADD DHCPRLY(Mandatory) DHCP Relay ID. None None Interval Type 0~63 0~63 None None None BSC6900None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
DIESELENGINESAVESWITCH Diesel engine save switch BSC6900 SET BTSDPMUBP(Optional) Whether to enable the diesel engine save switch GBFD-111202O&M of BTS Enumeration Type DISABLE(DISABLE), ENABLE(ENABLE) DISABLE, ENABLE None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DIFFBANDSDCCHUSINGOPTIMIZE different band SDCCH using optimize BSC6900 SET GCELLCHMGBASIC(Optional) Whether to allow an MS to report the classmark and whether to hand over the MS from the SDCCH in the frequency band for the main BCCH to the SDCCH in a different frequency band according to the classmark GBFD-110608GBFD-111005 SDCCH Handover Enhanced Channel Assignment Algorithm Enumeration Type NO(No), YES(Yes)NO, YES None None NO Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter takes effect only when the SDCCH exists on the TRXs on different frequency bands.
DINM Date in Month BSC6900 ADD SUBTSK(Mandatory) Day in the month on which the command can be executed. GBFD-111203O&M of BSC Enumeration Type MON_1(No.1), MON_2(No.2), MON_3(No.3), MON_4(No.4), MON_5(No.5), MON_6(No.6), MON_7(No.7), MON_8(No.8), MON_9(No.9), MON_10(No.10), MON_11(No.11), MON_12(No.12), MON_13(No.13), MON_14(No.14), MON_15(No.15), MON_16(No.16), MON_17(No.17), MON_18(No.18), MON_19(No.19), MON_20(No.20), MON_21(No.21), MON_22(No.22), MON_23(No.23), MON_24(No.24), MON_25(No.25), MON_26(No.26), MON_27(No.27), MON_28(No.28), MON_29(No.29), MON_30(No.30), MON_31(No.31) MON_1~MON_31 None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DINW Date in Week BSC6900 ADD SUBTSK(Mandatory) Day in the week on which the command can be executed. GBFD-111203O&M of BSC Enumeration Type SUN(Sunday), MON(Monday), TUE(Tuesday), WED(Wednesday), THU(Thursday), FRI(Friday), SAT(Saturday) SUN, MON, TUE, WED, THU, FRI, SAT None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DIR Directory BSC6900 DLD LICENSE(Mandatory)ULD LICENSE(Mandatory) Path of the FTP server where the file to be loaded is stored GBFD-111203MRFD-210403 O&M of BSCLicense Management String Type None 1~128 charaters None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DIR File Directory BSC6900 DLD BTSSW(Optional)DLD RETANTCFG(Optional)DLD BTSPATCH(Optional)ULD BTSLOG(Optional) Directory of the software to be downloaded GBFD-111202O&M of BTS String Type None 1~256 characters None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DirectedRetryAssFailSendEnable Directed Retry AssFail Send Enable BSC6900 SET AITFOTHPARA(Optional) Whether the BSC sends an Assignment Fail message with the cause value of directed retry to the MSC before the BSC initiates a directed retry procedure GBFD-110607Direct Retry Enumeration Type NO(No), YES(Yes)NO, YES None None NO MSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The setting of this parameter needs negotiation with the MSC of the opposite network element.If the MSC supports processing assignment failure messages containing the cause value of direct retry, set this parameter to YES; otherwise, set this parameter to NO.
DIRECTRYEN Directed Retry BSC6900 SET GCELLBASICPARA(Optional) Whether to enable the directed retry. The directed retry is to hand over an MS to a neighboring cell in the same procedure as the handover.The directed retry is an emergency measure applicable to abnormal traffic peaks in some areas of a radio network. You should not use the directed retry as a major means of solving traffic congestion. If the directed retry always occurs in some areas of a network, consider adjusting the sector and TRX configuration and the network layout of the BTS. GBFD-110607Direct Retry Enumeration Type NO(No), YES(Yes)NO, YES None None YES Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DIRMAGANSITEFLAG Directly Magnifier BTS Flag BSC6900 SET GCELLSOFT(Optional) Whether a cell is a repeater. With simpler functions than a BTS, a repeater is a coverage extension device of a BTS. It is applied to widely-stretched areas or indoor areas to solve the dead zone problem of BTS coverage. Using repeaters cannot increase the traffic capacity of a network but improve the coverage only. Because the BTS coverage increases, however, the total traffic improves accordingly.The setting of this parameter has effects on handovers. Repeaters use the asynchronous transfer mode (ATM) due to a greater distance between them. Therefore, handovers between repeaters are asynchronous. Synchronous handovers will fail. GBFD-110601HUAWEI I Handover Enumeration Type NO(No), YES(Yes)NO, YES None None NO Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved If the value of this parameter is YES, the intra-BSC handovers (including intra-cell handovers) in which the cell is the source or destination cell are processed as asynchronous handovers.
DisconnectHandoverProtectTimer Disconnect Handover Protect Timer BSC6900 SET OTHSOFTPARA(Optional) Timer to control the duration in which the BSC prevents the handover of an MS from which the BSC receives the Disconnect message. If the MS is handed over to a new cell after the MS sends the Disconnect message, the MS cannot receive the Release Acknowledgement message from the original cell. Thus, the MS cannot be disconnected. To protect from such a disconnection failure, the BSC does not hand over the MS within the duration of this timer after the BSC receives the Disconnect message from the MS. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 0~15 0~15 s None 3 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved If this parameter is set to 15, this protection is disabled.
DIVERSITY Diversity BSC6900 ADD GEXT3GCELL(Optional)SET GCELLHOFDDBA2(Mandatory)SET GCELLHOTDDBA2(Mandatory) Whether to activate transmit diversity on the common channel of a 3G cell GBFD-114301GSM/WCDMA Interoperability Enumeration Type NO(No), YES(Yes)NO, YES None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DIVERT16QAMDELAY Diversity Transmitter 16QAM Delay BSC6900 SET GCELLBASICPARA(Optional) Diversity transmitter 16QAM delay. Only the double-transceiver BTS and the subsequent distributed BTS support the function of transmit diversity delay. Therefore, this parameter applies to only the BTS of these two types. For the BTS of other types, this parameter is set to an invalid value 255. GBFD-510804Downlink EGPRS2-A Interval Type 4~32 0.5~4, step: 1/8 bit None 8 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter applies to only the double-transceiver BTS and the corresponding distributed BTS.
DIVERT32QAMDELAY Diversity Transmitter 32QAM Delay BSC6900 SET GCELLBASICPARA(Optional) Diversity transmitter 32QAM delay. Only the double-transceiver BTS and the subsequent distributed BTS support the function of transmit diversity delay. Therefore, this parameter applies to only the BTS of these two types. For the BTS of other types, this parameter is set to an invalid value 255. GBFD-510804Downlink EGPRS2-A Interval Type 4~32 0.5~4, step: 1/8 bit None 8 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter applies to only the double-transceiver BTS and the corresponding distributed BTS.
DIVERT8PSKDELAY Diversity Transmitter 8PSK Delay BSC6900 SET GCELLBASICPARA(Optional) Time delay of the transmit diversity. Currently, the parameter is set to 2 bit (7.4 us), applicable to general fading environments. A transmit diversity can generally obtain the gain of 3 dB to 5 dB. Because the fading conditions vary with the environment where an MS lies, however, MSs in a fixed time delay obtain different gains, which may have negative effects on some codes of the EDGE service. Therefore, the time delay of transmit diversity must be configurable and can be separately set for GMSK and 8PSK. Only the BTSs of double-transceiver series and the subsequent distributed BTSs support the function of transmit diversity delay. Only the BTSs of these types can be configured with this parameter. The BTSs of other types do not support setting this parameter and the parameter is fixed to an invalid value 255. GBFD-510804Downlink EGPRS2-A Interval Type 4~32 0.5~4, step: 1/8 bit None 8 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DivSwitch Four Diversity Receiver BSC6900 SET BTSRXUBP(Optional) Whether to support transmitting diversity or four diversity receiving GBFD-115902Transmit Diversity Enumeration Type N0(No), YES(Yes) NO, YES None NO None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DLADJPRD PwrCtrlDLAdjPeriod BSC6900 SET GCELLPWR3(Optional) Minimum interval between two consecutive downlink power control commands GBFD-117601HUAWEI III Power Control Algorithm Interval Type 0~255 0~255, step:480 for TCH and 470 for SDCCH ms None 2 Cell This parameter is valid only when "PWRCTRLSW" in "SET GCELLPWRBASIC" is set to PWR3. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DLAFSREXQUALHIGHTHRED DLAFSRexQualHighThred BSC6900 SET GCELLPWR3(Optional) If the downlink receive quality level of an AMR full rate call is greater than this parameter, the call needs to undergo Huawei power control generation III. GBFD-117601HUAWEI III Power Control Algorithm Interval Type 1~30 1~30 dB None 16 Cell This parameter is valid only when "PWRCTRLSW" in "SET GCELLPWRBASIC" is set to PWR3. The following condition must be met: "DLAFSREXQUALHIGHTHRED" >= "DLAFSREXQUALLOWTHRED". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DLAFSREXQUALLOWTHRED DLAFSRexQualLowThred BSC6900 SET GCELLPWR3(Optional) If the downlink receive quality level of an AMR full rate call is smaller than this parameter, the call needs to undergo Huawei power control generation III. GBFD-117601HUAWEI III Power Control Algorithm Interval Type 1~30 1~30 dB None 12 Cell This parameter is valid only when "PWRCTRLSW" in "SET GCELLPWRBASIC" is set to PWR3. The following condition must be met: "DLAFSREXQUALHIGHTHRED" >= "DLAFSREXQUALLOWTHRED". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DLAHSREXQUALHIGHTHRED DLAHSRexQualHighThred BSC6900 SET GCELLPWR3(Optional) If the downlink receive quality level of an AMR half rate call is greater than this parameter, the call needs to undergo Huawei power control generation III. GBFD-117601HUAWEI III Power Control Algorithm Interval Type 1~30 1~30 dB None 16 Cell This parameter is valid only when "PWRCTRLSW" in "SET GCELLPWRBASIC" is set to PWR3. The following condition must be met: "DLAHSREXQUALHIGHTHRED" >= "DLAFSREXQUALLOWTHRED". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DLAHSREXQUALLOWTHRED DLAHSRexQualLowThred BSC6900 SET GCELLPWR3(Optional) If the downlink receive quality level of an AMR half rate call is smaller than this parameter, the call needs to undergo Huawei power control generation III. GBFD-117601HUAWEI III Power Control Algorithm Interval Type 1~30 1~30 dB None 12 Cell This parameter is valid only when "PWRCTRLSW" in "SET GCELLPWRBASIC" is set to PWR3. The following condition must be met: "DLAHSREXQUALHIGHTHRED" >= "DLAFSREXQUALLOWTHRED". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DLCI The Identifier of Data Link Connection BSC6900 ADD NSVC(Mandatory) ID of the data link connection of the NSVC. It is an interworking parameter which must be consistent on the BSC and the peer. GBFD-510002Gb Over FR Interval Type 16~1007 16~1007 None None None NSVC None Read & Write Y NSVC Less than 5 minutes This parameter is related to the actual physical connection of the BC. This parameter is modified only when the NSVC service is faulty.
DLCOEFFICIENTTSRAPIDADJ Fast DL Priority Decision Threshold BSC6900 SET BSCPSSOFTPARA(Optional) If the ratio of downlink flow to uplink flow is greater than or equal to the value of this parameter during the fast flux measurement, the downlink services takes priority. GBFD-119501Adaptive Adjustment of Uplink and Downlink Channels Interval Type 1~255 1~255 None None 5 BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved If this parameter is set to a small value, the detection of service type is sensitive and may lead to ping-pong handover between different services.
DLDCSPT Support Downlink Dual-Carrier BSC6900 SET GCELLGPRS(Optional) Whether the cell supports DLDC. GBFD-510802Dual Carriers in Downlink Enumeration Type UNSUPPORT(Not Support), SUPPORT(Support) UNSUPPORT, SUPPORT None None None Cell This parameter is valid only when "EDGE" is set to Support. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DLEDGETHRES Edge HO DL RX_LEV Threshold BSC6900 SET GCELLHOBASIC(Optional) Threshold for downlink edge handover. If the downlink receive level remains less than this threshold for a period of time, the edge handover is triggered. If the PBGT handover algorithm is enabled, this threshold can be decreased accordingly. If the PBGT handover algorithm is disabled, over-coverage, co-channel interference, and adjacent channel interference may occur when this threshold is set improperly. In addition, to ensure uplink-downlink balance, this threshold needs to be adjusted according to the handover performance statistics and actual network performance. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 0~63 0~63 dB None 20 Cell This parameter is valid when "FRINGEHOEN" is set to YES or "LOADHOEN" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DLFILTADJFACTOR III DL Filter Adjust Factor BSC6900 SET GCELLPWR3(Optional) Filter adjustment factor for downlink power control. Setting this parameter high helps to smooth the filtered values and to reduce the impact of poor measurement reports on the filtered values. Setting this parameter low helps to draw the filtered values close to the actual values and to heighten the power control effect. GBFD-117601HUAWEI III Power Control Algorithm Interval Type 1~10 1~10 None None 3 Cell This parameter is valid only when "PWRCTRLOPTIMIZEDEN" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DLFSREXQUALHIGHTHRED DLFSRexQualHighThred BSC6900 SET GCELLPWR3(Optional) Upper quality threshold for Huawei power control generation III on a full rate call. If the downlink receive quality level of a full rate call is greater than this threshold, the call needs to undergo Huawei power control generation III. GBFD-117601HUAWEI III Power Control Algorithm Interval Type 1~30 1~30 dB None 16 Cell This parameter is valid only when "PWRCTRLSW" in "SET GCELLPWRBASIC" is set to PWR3. The following condition must be met: "DLFSREXQUALHIGHTHRED" >= "DLFSREXQUALLOWTHRED". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DLFSREXQUALLOWTHRED DLFSRexQualLowThred BSC6900 SET GCELLPWR3(Optional) Lower quality threshold for Huawei power control generation III on a full rate call. If the downlink receive quality level of a full rate call is smaller than this threshold, the call needs to undergo Huawei power control generation III. GBFD-117601HUAWEI III Power Control Algorithm Interval Type 1~30 1~30 dB None 16 Cell This parameter is valid only when "PWRCTRLSW" in "SET GCELLPWRBASIC" is set to PWR3. The following condition must be met: "DLFSREXQUALHIGHTHRED" >= "DLFSREXQUALLOWTHRED". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DlGprsTbfExpandOp Downlink GPRS TBF Window Expansion Optimization BSC6900 SET GCELLPSOTHERPARA(Optional) Expanded size of the GPRS RLC window. This parameter is used to expand the size of the GRPS RLC window. The expanded window size breaks the restrictions of 64 defined in the protocol and reduces the probability of GRPS RLC window stopping. GBFD-114101GPRS Interval Type 0~127 0~127 None None 0 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DLHSREXQUALHIGHTHRED DLHSRexQualHighThred BSC6900 SET GCELLPWR3(Optional) Upper quality threshold for Huawei power control generation III on a half rate call. If the downlink receive quality level of a half rate call is greater than this threshold, the call needs to undergo Huawei power control generation III. GBFD-117601HUAWEI III Power Control Algorithm Interval Type 1~30 1~30 dB None 18 Cell This parameter is valid only when "PWRCTRLSW" in "SET GCELLPWRBASIC" is set to PWR3. The following condition must be met: "DLHSREXQUALHIGHTHRED" >= "DLHSREXQUALLOWTHRED". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DLHSREXQUALLOWTHRED DLHSRexQualLowThred BSC6900 SET GCELLPWR3(Optional) Lower quality threshold for Huawei power control generation III on a half rate call. If the downlink receive quality level of a half rate call is smallter than this threshold, the call needs to undergo Huawei power control generation III. GBFD-117601HUAWEI III Power Control Algorithm Interval Type 1~30 1~30 dB None 18 Cell This parameter is valid only when "PWRCTRLSW" in "SET GCELLPWRBASIC" is set to PWR3. The following condition must be met: "DLHSREXQUALHIGHTHRED" >= "DLHSREXQUALLOWTHRED". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DLHYSTF1 AMR DL Coding Rate adj.hyst1[F] BSC6900 SET GCELLCCAMR(Optional) Adjustment hysteresis 1 of AMR downlink coding rate (full rate). According to a certain algorithm and the radio quality indication (RQI) in the call measurement report, the MS and the BTS automatically adjust the current speech coding and decoding rate. The adjustment threshold of coding rate is the threshold of the RQI, which is the carrier-to-interference ratio of a call. The RQI value 1 means 0.5 dB, the RQI value 2 means 1 dB, and others can be deducted by analogy. There may be multiple coding rates in the active coding set (ACS). Therefore, there is an adjustment threshold and an adjustment hysteresis between every two adjacent coding rates. GBFD-115501AMR FR Interval Type 0~15 0~15 None None None Cell The setting of this parameter must meet the following condition: "DLTHF1" + "DLHYSTF1" < "DLTHF2" + "DLHYSTF2". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DLHYSTF2 AMR DL Coding Rate adj.hyst2[F] BSC6900 SET GCELLCCAMR(Optional) Adjustment hysteresis 2 of AMR downlink coding rate (full rate). According to a certain algorithm and the radio quality indication (RQI) in the call measurement report, the MS and the BTS automatically adjust the current speech coding and decoding rate. The adjustment threshold of coding rate is the threshold of the RQI, which is the carrier-to-interference ratio of a call. The RQI value 1 means 0.5 dB, the RQI value 2 means 1 dB, and others can be deducted by analogy. There may be multiple coding rates in the active coding set (ACS). Therefore, there is an adjustment threshold and an adjustment hysteresis between every two adjacent coding rates. GBFD-115501AMR FR Interval Type 0~15 0~15 None None None Cell The setting of this parameter must meet the following condition: "DLTHF2" + "DLHYSTF2" < "DLTHF3" + "DLHYSTF3". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DLHYSTF3 AMR DL Coding Rate adj.hyst3[F] BSC6900 SET GCELLCCAMR(Optional) Adjustment hysteresis 3 of AMR downlink coding rate (full rate). According to a certain algorithm and the radio quality indication (RQI) in the call measurement report, the MS and the BTS automatically adjust the current speech coding and decoding rate. The adjustment threshold of coding rate is the threshold of the RQI, which is the carrier-to-interference ratio of a call. The RQI value 1 means 0.5 dB, the RQI value 2 means 1 dB, and others can be deducted by analogy. There may be multiple coding rates in the active coding set (ACS). Therefore, there is an adjustment threshold and an adjustment hysteresis between every two adjacent coding rates. GBFD-115501AMR FR Interval Type 0~15 0~15 None None None Cell The setting of this parameter must meet the following condition: "DLTHF2" + "DLHYSTF2" < "DLTHF3" + "DLHYSTF3". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DLHYSTH1 AMR DL Coding Rate adj.hyst1[H] BSC6900 SET GCELLCCAMR(Optional) Adjustment hysteresis 1 of AMR downlink coding rate (half rate). According to a certain algorithm and the radio quality indication (RQI) in the call measurement report, the MS and the BTS automatically adjust the current speech coding and decoding rate. The adjustment threshold of coding rate is the threshold of the RQI, which is the carrier-to-interference ratio of a call. The RQI value 1 means 0.5 dB, the RQI value 2 means 1 dB, and others can be deducted by analogy. There may be multiple coding rates in the active coding set (ACS). Therefore, there is an adjustment threshold and an adjustment hysteresis between every two adjacent coding rates. GBFD-115502AMR HR Interval Type 0~15 0~15 None None None Cell The setting of this parameter must meet the following condition: "DLTHH1" + "DLHYSTH1" < "DLTHH2" + "DLHYSTH2". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DLHYSTH2 AMR DL Coding Rate adj.hyst2[H] BSC6900 SET GCELLCCAMR(Optional) Adjustment hysteresis 2 of AMR downlink coding rate (half rate). According to a certain algorithm and the radio quality indication (RQI) in the call measurement report, the MS and the BTS automatically adjust the current speech coding and decoding rate. The adjustment threshold of coding rate is the threshold of the RQI, which is the carrier-to-interference ratio of a call. The RQI value 1 means 0.5 dB, the RQI value 2 means 1 dB, and others can be deducted by analogy. There may be multiple coding rates in the active coding set (ACS). Therefore, there is an adjustment threshold and an adjustment hysteresis between every two adjacent coding rates. GBFD-115502AMR HR Interval Type 0~15 0~15 None None None Cell The setting of this parameter must meet the following condition: "DLTHH2" + "DLHYSTH2" < "DLTHH3" + "DLHYSTH3". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DLHYSTH3 AMR DL Coding Rate adj.hyst3[H] BSC6900 SET GCELLCCAMR(Optional) Adjustment hysteresis 3 of AMR downlink coding rate (half rate). According to a certain algorithm and the radio quality indication (RQI) in the call measurement report, the MS and the BTS automatically adjust the current speech coding and decoding rate. The adjustment threshold of coding rate is the threshold of the RQI, which is the carrier-to-interference ratio of a call. The RQI value 1 means 0.5 dB, the RQI value 2 means 1 dB, and others can be deducted by analogy. There may be multiple coding rates in the active coding set (ACS). Therefore, there is an adjustment threshold and an adjustment hysteresis between every two adjacent coding rates. GBFD-115502AMR HR Interval Type 0~15 0~15 None None None Cell The setting of this parameter must meet the following condition: "DLTHH2" + "DLHYSTH2" < "DLTHH3" + "DLHYSTH3". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DLHYSTWB1 AMR DL Coding Rate adj.hyst1[WB] BSC6900 SET GCELLCCAMR(Optional) Adjustment hysteresis 1 of AMR downlink coding rate (wide band). According to a certain algorithm and the radio quality indication (RQI) in the call measurement report, the MS and the BTS automatically adjust the current speech coding and decoding rate. The adjustment threshold of coding rate is the threshold of the RQI, which is the carrier-to-interference ratio of a call. The RQI value 1 means 0.5 dB, the RQI value 2 means 1 dB, and others can be deducted by analogy. There may be multiple coding rates in the active coding set (ACS). Therefore, there is an adjustment threshold and an adjustment hysteresis between every two adjacent coding rates. GBFD-115507WB AMR Interval Type 0~15 0~15 None None 2 Cell The setting of this parameter must meet the following condition: "DLTHWB1" + "DLHYSTWB1" < "DLTHWB2" + "DLHYSTWB2". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DLHYSTWB2 AMR DL Coding Rate adj.hyst2[WB] BSC6900 SET GCELLCCAMR(Optional) Adjustment hysteresis 2 of AMR downlink coding rate (wide band). According to a certain algorithm and the radio quality indication (RQI) in the call measurement report, the MS and the BTS automatically adjust the current speech coding and decoding rate. The adjustment threshold of coding rate is the threshold of the RQI, which is the carrier-to-interference ratio of a call. The RQI value 1 means 0.5 dB, the RQI value 2 means 1 dB, and others can be deducted by analogy. There may be multiple coding rates in the active coding set (ACS). Therefore, there is an adjustment threshold and an adjustment hysteresis between every two adjacent coding rates. GBFD-115507WB AMR Interval Type 0~15 0~15 None None 2 Cell The setting of this parameter must meet the following condition: "DLTHWB1" + "DLHYSTWB1" < "DLTHWB2" + "DLHYSTWB2". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DLINTERFLEVLIMIT Interf.of DL Level Threshold BSC6900 SET GCELLCHMGAD(Optional) Threshold for determining whether downlink interference exists. If the downlink level is equal to or greater than "Interf.of DL Level Threshold" and the downlink quality level is equal to or greater than "Interf.of DL Qual.Threshold", downlink interference exists. The value range 0 to 63 is mapped to the range -110 dBm to -47 dBm. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 0~63 0~63 dB None 35 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DLINTERFQUALLIMIT Interf.of DL Qual.Threshold BSC6900 SET GCELLCHMGAD(Optional) Threshold for determining whether downlink interference exists. If the downlink level is equal to or greater than "Interf.of DL Level Threshold" and the downlink quality level is equal to or greater than "Interf.of DL Qual.Threshold", downlink interference exists. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 0~70 0~70 None None 40 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DlLdrThrd2GCell 2G Cell DL Basic Congest Thred BSC6900 SET GCELLHOINTERRATLDB(Optional) Threshold of downlink Basic Congestion state in a 2G Cell MRFD-211402MBSC Load Balancing Interval Type 1~100 {1~100} None None None BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DLLEVFILTLEN Filter Length for DL RX_LEV BSC6900 SET GCELLPWR2(Optional) Number of measurement reports sampled for averaging downlink signal strength. A single measurement report may not reflect the actual network situations accurately. Therefore, the BSC needs to average the measured values in several successive measurement reports to reflect the radio environment. GBFD-110703Enhanced Power Control Algorithm Interval Type 1~20 1~20, step:480 for TCH and 470 for SDCCH ms None 5 Cell This parameter is valid when "PWRCTRLSW" in the "SET GCELLPWRBASIC" command is set to PWR2 and "DNPCEN" in the "SET GCELLBASICPARA" command is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DLLTFERTGT Downlink Long-term FER Target BSC6900 SET GCELLCCAMR(Optional) Target value of the voice quality automatically adjusted through the downlink threshold of AMR handover GBFD-115506AMR Coding Rate Threshold Adaptive Adjustment Interval Type 2~255 2~255 None None The recommended value is 8 when DTX is disabled.The recommended value is 14 when DTX is enabled. Cell The setting of this parameter must meet the following condition: "LTFERLOWTH" < "DLLTFERTGT" < "LTFERUPTH". Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter is used for the adaptive adjustment function of AMR downlink threshold. When the voice is in poor performance not being affected by the channel quality: If the low rate mode is more used in the adaptation, you can increase the value of this parameter; if the high rate mode is more used in the adaptation, you can decrease the value of this parameter. The adjustment range is from 4 to 20 and the adjustment step is 2.The target FER with the discontinuous transmission (DTX) enabled is a little higher than the one without the DTX enabled. It is recommended that you set the value of this parameter to 14 when the DTX is enabled. Based on this value, you can make adjustments in the above mentioned principle according to actual test results.
DLMAXDOWNSTEP DLMAXDownStep BSC6900 SET GCELLPWR3(Optional) Maximum step by which to decrease downlink power according to signal strength GBFD-117601HUAWEI III Power Control Algorithm Interval Type 1~30 1~30 dB None 4 Cell This parameter is valid only when "PWRCTRLSW" in "SET GCELLPWRBASIC" is set to PWR3. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DLMAXUPSTEP DLMAXUpStep BSC6900 SET GCELLPWR3(Optional) Maximum step by which to increase downlink power according to signal strength GBFD-117601HUAWEI III Power Control Algorithm Interval Type 1~30 1~30 dB None 8 Cell This parameter is valid only when "PWRCTRLSW" in "SET GCELLPWRBASIC" is set to PWR3. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DlOlcThrd2GCell 2G Cell DL Overload Congest Thred BSC6900 SET GCELLHOINTERRATLDB(Optional) Threshold of downlink overload congestion state in a 2G Cell MRFD-211402MBSC Load Balancing Interval Type 1~100 {1~100} None None None BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DLPREDLEND DL MR. Number Predicted BSC6900 SET GCELLPWR2(Optional) Number of downlink measurement reports that the BSC predicts. The BSC takes a while to confirm the power control effect of a power control command. Thus, the BSC makes a power control decision based on a measurement report that lags behind the changes in the receive level and quality instead of reflecting the real-time radio environment. As a result, the power control is late.To prevent late power control to a certain degree, the power control algorithm involves a measurement report prediction filter. The BSC can sample several downlink measurement reports in a short time and then weight them to predict future N measurement reports.This parameter specifies the number N. GBFD-110703Enhanced Power Control Algorithm Interval Type 0~3 0~3 None None 0 Cell This parameter is valid when "PWRCTRLSW" in the "SET GCELLPWRBASIC" command is set to PWR2 and "DNPCEN" in the "SET GCELLBASICPARA" command is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DLQHIGHTHRED DL Qual. Upper Threshold BSC6900 SET GCELLPWRBASIC(Optional) Quality level threshold for decreasing downlink signal power. If the BTS transmits signals at a quality level less than this threshold, the BSC decreases the power of the BTS. If (downlink receive level - "MAX Down Adj. PC Value by Qual.") < "DL RX_LEV Lower Threshold", however, the BSC does not adjust the transmit power. GBFD-110703Enhanced Power Control Algorithm Interval Type 0~7 0~7 None None 0 Cell This parameter is valid only when "PWRCTRLSW" in "SET GCELLPWRBASIC" is set to PWR2. The following condition must be met: "DLQLOWTHRED" >= "DLQHIGHTHRED". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DLQLOWTHRED DL Qual. Lower Threshold BSC6900 SET GCELLPWRBASIC(Optional) Quality level threshold for increasing downlink signal power. If the BTS transmits signals at a quality level greater than this threshold, the BSC increases the power of the BTS. If (downlink receive level + "MAX Up Adj. PC Value by Qual.") > "DL RX_LEV Upper Threshold", however, the BSC does not adjust the transmit power. GBFD-110703Enhanced Power Control Algorithm Interval Type 0~7 0~7 None None 2 Cell This parameter is valid only when "PWRCTRLSW" in "SET GCELLPWRBASIC" is set to PWR2. The following condition must be met: "DLQLOWTHRED" >= "DLQHIGHTHRED". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DLQUAFILTLEN Filter Length for DL Qual. BSC6900 SET GCELLPWR2(Optional) Number of measurement reports sampled for averaging downlink signal quality. A single measurement report may not reflect the actual network situations accurately. Therefore, the BSC needs to average the measured values in several successive measurement reports to reflect the radio environment. GBFD-110703Enhanced Power Control Algorithm Interval Type 1~20 1~20, step:480 for TCH and 470 for SDCCH ms None 5 Cell This parameter is valid when "PWRCTRLSW" in the "SET GCELLPWRBASIC" command is set to PWR2 and "DNPCEN" in the "SET GCELLBASICPARA" command is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DLQUALBADTRIG DL Qual. Bad Trig Threshold BSC6900 SET GCELLPWR2(Optional) During downlink power control, if the downlink receive quality level is equal to or greater than "DL Qual, bad Trig Threshold", "DL RX_LEV Upper Threshold" is increased by "DL Qual. Bad UpLEVDiff" to further increase the expected downlink power level. GBFD-110703Enhanced Power Control Algorithm Interval Type 0~7 0~7 None None 2 Cell This parameter is valid when "PWRCTRLSW" in the "SET GCELLPWRBASIC" command is set to PWR2. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DLQUALBADUPLEV DL Qual. Bad UpLEVDiff BSC6900 SET GCELLPWR2(Optional) During downlink power control, if the downlink receive quality level is equal to or greater than "DL Qual, bad Trig Threshold", "DL RX_LEV Upper Threshold" is increased by "DL Qual. Bad UpLEVDiff" to further increase the expected downlink power level. GBFD-110703Enhanced Power Control Algorithm Interval Type 0~63 0~63 dB None 10 Cell This parameter is valid when "PWRCTRLSW" in the "SET GCELLPWRBASIC" command is set to PWR2. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DLQUALIMIT DL Qual. Threshold BSC6900 SET GCELLHOEMG(Optional) Downlink quality threshold for emergency handover. This parameter is represented as the product of 10 and a quality level that ranges from 0 to 7. The emergency handover can be triggered only when the downlink receive quality of an MS is greater(indicate bad quality) than this threshold. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 0~70 0~70 None None 55 Cell This parameter is valid only when "BQHOEN" in "SET GCELLHOBASIC" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DLQUALIMITAMRFR DL Qual. Limit for AMR FR BSC6900 SET GCELLAMRQUL(Optional) Downlink quality limit for emergency handover in an AMR full rate call. The value of this parameter corresponds to the quality levels (0 to 7) multiplied by 10. An emergency handover can be triggered only when the downlink reception quality of an MS is higher than the value of this parameter, which indicates a poor quality. GBFD-115501AMR FR Interval Type 0~70 0~70 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The setting of this parameter affects the triggering of a handover for poor quality in an AMR full rate call. The smaller the value of this parameter is, the easier a downlink handover due to a poor quality occurs.
DLQUALIMITAMRHR DL Qual. Limit for AMR HR BSC6900 SET GCELLAMRQUL(Optional) Downlink quality limit for emergency handover in an AMR half rate call. The value of this parameter corresponds to the quality levels (0 to 7) multiplied by 10. An emergency handover can be triggered only when the downlink reception quality of an MS is higher than the value of this parameter, which indicates a poor quality. GBFD-115502AMR HR Interval Type 0~70 0~70 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The setting of this parameter affects the triggering of a handover for poor quality in an AMR half rate call. The smaller the value of this parameter is, the easier a downlink handover due to a poor quality occurs.
DLREXLEVADJFCTR DLRexLevAdjustFactor BSC6900 SET GCELLPWR3(Optional) Percentage of signal strength in the factors by which to determine the downlink power control step GBFD-117601HUAWEI III Power Control Algorithm Interval Type 0~10 0~10 None None 6 Cell This parameter is valid only when "PWRCTRLSW" in "SET GCELLPWRBASIC" is set to PWR3. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DLREXLEVEXPFLTLEN DLRexLevExponentFilterLen BSC6900 SET GCELLPWR3(Optional) Length of the exponential filter for downlink signal strength. A single measurement report may not reflect the actual network situations accurately. Therefore, the BSC needs to filter the measured values in several successive measurement reports to reflect the radio environment. GBFD-117601HUAWEI III Power Control Algorithm Interval Type 0~19 0~19, step:480 for TCH and 470 for SDCCH ms None 3 Cell This parameter is valid only when "PWRCTRLSW" in "SET GCELLPWRBASIC" is set to PWR3. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DLREXLEVHIGHTHRED DLRexLevHighThred BSC6900 SET GCELLPWR3(Optional) Upper receive level threshold for downlink power control. If the downlink receive level is greater than this threshold, the power of the downlink signal needs to be decreased. GBFD-117601HUAWEI III Power Control Algorithm Interval Type 0~63 0~63 dB None 35 Cell This parameter is valid only when "PWRCTRLSW" in "SET GCELLPWRBASIC" is set to PWR3. The following condition must be met: "DLREXLEVHIGHTHRED" >= "DLREXLEVLOWTHRED". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DLREXLEVLOWTHRED DLRexLevLowthred BSC6900 SET GCELLPWR3(Optional) Lower receive level threshold for downlink power control. If the downlink receive level is smaller than this threshold, the power of the uplink signal needs to be increased. GBFD-117601HUAWEI III Power Control Algorithm Interval Type 0~63 0~63 dB None 25 Cell This parameter is valid only when "PWRCTRLSW" in "SET GCELLPWRBASIC" is set to PWR3. The following condition must be met: "DLREXLEVHIGHTHRED" >= "DLREXLEVLOWTHRED". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DLREXLEVSLDWINDOW DLRexLevSlideWindow BSC6900 SET GCELLPWR3(Optional) Length of the slide window filter for downlink signal strength. A single measurement report may not reflect the actual network situations accurately. Therefore, the BSC needs to filter the measured values in several successive measurement reports to reflect the radio environment. GBFD-117601HUAWEI III Power Control Algorithm Interval Type 1~20 1~20, step:480 for TCH and 470 for SDCCH ms None 1 Cell This parameter is valid only when "PWRCTRLSW" in "SET GCELLPWRBASIC" is set to PWR3. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DLREXQUALADJFCTR DLRexQualAdjustFactor BSC6900 SET GCELLPWR3(Optional) Percentage of quality level in the factors by which to determine the downlink power control step GBFD-117601HUAWEI III Power Control Algorithm Interval Type 0~10 0~10 None None 6 Cell This parameter is valid only when "PWRCTRLSW" in "SET GCELLPWRBASIC" is set to PWR3. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DLREXQUALEXPFLTLEN DLRexQualExponentFilterLen BSC6900 SET GCELLPWR3(Optional) Length of the exponential filter for downlink signal quality. A single measurement report may not reflect the actual network situations accurately. Therefore, the BSC needs to filter the measured values in several successive measurement reports to reflect the radio environment. GBFD-117601HUAWEI III Power Control Algorithm Interval Type 0~19 0~19, step:480 for TCH and 470 for SDCCH ms None 3 Cell This parameter is valid only when "PWRCTRLSW" in "SET GCELLPWRBASIC" is set to PWR3. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DLREXQUALSLDWINDOW DLRexQualSlideWindow BSC6900 SET GCELLPWR3(Optional) Length of the slide window filter for downlink signal quality. A single measurement report may not reflect the actual network situations accurately. Therefore, the BSC needs to filter the measured values in several successive measurement reports to reflect the radio environment. GBFD-117601HUAWEI III Power Control Algorithm Interval Type 1~20 1~20, step:480 for TCH and 470 for SDCCH ms None 1 Cell This parameter is valid only when "PWRCTRLSW" in "SET GCELLPWRBASIC" is set to PWR3. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DLRXLEVPROTECTFACTOR III DL RexLev Protect Factor BSC6900 SET GCELLPWR3(Optional) A power control step cannot exceed the step computed according to "III DL RexLev Protect Factor" and "III DL RexQual Protect Factor". GBFD-117601HUAWEI III Power Control Algorithm Interval Type 0~100 0~100 None None 5 Cell This parameter is valid only when "PWRCTRLOPTIMIZEDEN" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DLRXQUALPROTECTFACTOR III DL RexQual Protect Factor BSC6900 SET GCELLPWR3(Optional) A power control step cannot exceed the step computed according to "III DL RexLev Protect Factor" and "III DL RexQual Protect Factor". GBFD-117601HUAWEI III Power Control Algorithm Interval Type 0~100 0~100 None None 55 Cell This parameter is valid only when "PWRCTRLOPTIMIZEDEN" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DLSSHIGHTHRED DL RX_LEV Upper Threshold BSC6900 SET GCELLPWRBASIC(Optional) Upper threshold for downlink signal strengthIf the downlink received signal level is greater than this threshold, a power decrease is computed. Then, the power is decreased by the least of the power decrease, maximum power adjustment step allowed by the quality zone to which the received signal quality belongs, and "MAX Down Adj. PC Value by Qual.".Power decrease = downlink received signal level - ("DL RX_LEV Upper Threshold" + "AMR DL RX_LEV Lower Threshold")/2The maximum power adjustment step allowed by the quality zone is chosen from "MAX Down Adj.Value Qual.Zone 0", "MAX Down Adj.Value Qual.Zone 1", and "MAX Down Adj.Value Qual.Zone 2" according to the quality zone. GBFD-110703Enhanced Power Control Algorithm Interval Type 0~63 0~63 dB None 45 Cell This parameter is valid only when "PWRCTRLSW" in "SET GCELLPWRBASIC" is set to PWR2. The following condition must be met: "DLSSHIGHTHRED" >= "DLSSLOWTHRED". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DLSSLOWTHRED DL RX_LEV Lower Threshold BSC6900 SET GCELLPWRBASIC(Optional) Lower threshold for downlink signal strengthIf the downlink received signal level is less than this threshold, a power increase is computed. Then, the power is increased by the least of the power increase, "MAX Up Adj. PC Value by RX_LEV", and "MAX Up Adj. PC Value by Qual.".Power increase = ("DL RX_LEV Upper Threshold" + "AMR DL RX_LEV Lower Threshold")/2 - downlink received signal level GBFD-110703Enhanced Power Control Algorithm Interval Type 0~63 0~63 dB None 28 Cell This parameter is valid only when "PWRCTRLSW" in "SET GCELLPWRBASIC" is set to PWR2. The following condition must be met: "DLSSHIGHTHRED" >= "DLSSLOWTHRED". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DLTESTRESENDINT Download Test Resend Interval BSC6900 SET GCELLGSMR(Optional) Interval for resending downlink test messages GBFD-510301GBFD-510302 Public Voice Group Call ServicePublic Voice Broadcast Service Interval Type 0~255 0~255 s None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DLTESTRESENDNUM Download Test Resend Number BSC6900 SET GCELLGSMR(Optional) Number of times of the BSC resending downlink test messages after the downlink test function is enabled. If the BSC does not receive any response message from the MS at the preset interval, the BSC releases the relevant voice group call service (VGCS) channel. GBFD-510301GBFD-510302 Public Voice Group Call ServicePublic Voice Broadcast Service Interval Type 1~255 1~255 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DLTHF1 AMR DL Coding Rate adj.th1[F] BSC6900 SET GCELLCCAMR(Optional) Adjustment threshold 1 of AMR downlink coding rate (full rate). According to a certain algorithm and the RQI in the call measurement report, the MS and the BTS automatically adjust the current speech coding and decoding rate. The adjustment threshold of coding rate is the threshold of the RQI, which is the carrier-to-interference ratio of a call. The RQI value 1 means 0.5 dB, the RQI value 2 means 1 dB, and others can be deducted by analogy. There may be multiple coding rates in the ACS. Therefore, there is an adjustment threshold and an adjustment hysteresis between every two adjacent coding rates. GBFD-115501AMR FR Interval Type 0~63 0~63 dB None None Cell The setting of this parameter must meet the following conditions: "DLTHF1" < "DLTHF2";"DLTHF1" + "DLHYSTF1" < "DLTHF2" + "DLHYSTF2". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DLTHF2 AMR DL Coding Rate adj.th2[F] BSC6900 SET GCELLCCAMR(Optional) Adjustment threshold 2 of AMR downlink coding rate (full rate). According to a certain algorithm and the RQI in the call measurement report, the MS and the BTS automatically adjust the current speech coding and decoding rate. The adjustment threshold of coding rate is the threshold of the RQI, which is the carrier-to-interference ratio of a call. The RQI value 1 means 0.5 dB, the RQI value 2 means 1 dB, and others can be deducted by analogy. There may be multiple coding rates in the ACS. Therefore, there is an adjustment threshold and an adjustment hysteresis between every two adjacent coding rates. GBFD-115501AMR FR Interval Type 0~63 0~63 dB None None Cell The setting of this parameter must meet the following conditions: "DLTHF2" < "DLTHF3";"DLTHF2" + "DLHYSTF2" < "DLTHF3" + "DLHYSTF3". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DLTHF3 AMR DL Coding Rate adj.th3[F] BSC6900 SET GCELLCCAMR(Optional) Adjustment threshold 3 of AMR downlink coding rate (full rate). The adjustment thresholds and the hysteresis of coding rate must meet the following conditions: AMR Coding Rate adj.th (n) < AMR Coding Rate adj.th (n + 1), n = 1 or 2; [AMR Coding Rate adj.th (n) + AMR Coding Rate adj.hyst (n)] < [AMR Coding Rate adj.th (n + 1) + AMR Coding Rate adj.hyst (n + 1)], n = 1 or 2. GBFD-115501AMR FR Interval Type 0~63 0~63 dB None None Cell The setting of this parameter must meet the following conditions: "DLTHF2" < "DLTHF3"; "DLTHF2" + "DLHYSTF2" < "DLTHF3" + "DLHYSTF3". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DLTHH1 AMR DL Coding Rate adj.th1[H] BSC6900 SET GCELLCCAMR(Optional) Adjustment threshold 1 of AMR downlink coding rate (half rate). According to a certain algorithm and the RQI in the call measurement report, the MS and the BTS automatically adjust the current speech coding and decoding rate. The adjustment threshold of coding rate is the threshold of the RQI, which is the carrier-to-interference ratio of a call. The RQI value 1 means 0.5 dB, the RQI value 2 means 1 dB, and others can be deducted by analogy. There may be multiple coding rates in the ACS. Therefore, there is an adjustment threshold and an adjustment hysteresis between every two adjacent coding rates. GBFD-115502AMR HR Interval Type 0~63 0~63 dB None None Cell The setting of this parameter must meet the following conditions: "DLTHH1" < "DLTHH2"; "DLTHH1" + "DLHYSTH1" < "DLTHH2" + "DLHYSTH2". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DLTHH2 AMR DL Coding Rate adj.th2[H] BSC6900 SET GCELLCCAMR(Optional) Adjustment threshold 2 of AMR downlink coding rate (half rate). According to a certain algorithm and the RQI in the call measurement report, the MS and the BTS automatically adjust the current speech coding and decoding rate. The adjustment threshold of coding rate is the threshold of the RQI, which is the carrier-to-interference ratio of a call. The RQI value 1 means 0.5 dB, the RQI value 2 means 1 dB, and others can be deducted by analogy. There may be multiple coding rates in the ACS. Therefore, there is an adjustment threshold and an adjustment hysteresis between every two adjacent coding rates. GBFD-115502AMR HR Interval Type 0~63 0~63 dB None None Cell The setting of this parameter must meet the following conditions: "DLTHH2" < "DLTHH3"; "DLTHH2" + "DLHYSTH2" < "DLTHH3" + "DLHYSTH3". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DLTHH3 AMR DL Coding Rate adj.th3[H] BSC6900 SET GCELLCCAMR(Optional) Adjustment threshold 3 of AMR downlink coding rate (half rate). According to a certain algorithm and the RQI in the call measurement report, the MS and the BTS automatically adjust the current speech coding and decoding rate. The adjustment threshold of coding rate is the threshold of the RQI, which is the carrier-to-interference ratio of a call. The RQI value 1 means 0.5 dB, the RQI value 2 means 1 dB, and others can be deducted by analogy. There may be multiple coding rates in the ACS. Therefore, there is an adjustment threshold and an adjustment hysteresis between every two adjacent coding rates. GBFD-115502AMR HR Interval Type 0~63 0~63 dB None None Cell The setting of this parameter must meet the following conditions: "DLTHH2" < "DLTHH3"; "DLTHH2" + "DLHYSTH2" < "DLTHH3" + "DLHYSTH3". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DLTHWB1 AMR DL Coding Rate adj.th1[WB] BSC6900 SET GCELLCCAMR(Optional) Adjustment threshold 1 of AMR downlink coding rate (wide band). According to a certain algorithm and the RQI in the call measurement report, the MS and the BTS automatically adjust the current speech coding and decoding rate. The adjustment threshold of coding rate is the threshold of the RQI, which is the carrier-to-interference ratio of a call. The RQI value 1 means 0.5 dB, the RQI value 2 means 1 dB, and others can be deducted by analogy. There may be multiple coding rates in the ACS. Therefore, there is an adjustment threshold and an adjustment hysteresis between every two adjacent coding rates. GBFD-115507WB AMR Interval Type 0~63 0~63 dB None 12 Cell The setting of this parameter must meet the following conditions: "DLTHWB1" < "DLTHWB2"; ["DLTHWB1" + "DLHYSTWB1" < "DLTHWB2" + "DLHYSTWB2". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DLTHWB2 AMR DL Coding Rate adj.th2[WB] BSC6900 SET GCELLCCAMR(Optional) Adjustment threshold 2 of AMR downlink coding rate (wide band). According to a certain algorithm and the RQI in the call measurement report, the MS and the BTS automatically adjust the current speech coding and decoding rate. The adjustment threshold of coding rate is the threshold of the RQI, which is the carrier-to-interference ratio of a call. The RQI value 1 means 0.5 dB, the RQI value 2 means 1 dB, and others can be deducted by analogy. There may be multiple coding rates in the ACS. Therefore, there is an adjustment threshold and an adjustment hysteresis between every two adjacent coding rates. GBFD-115507WB AMR Interval Type 0~63 0~63 dB None 18 Cell The setting of this parameter must meet the following conditions: "DLTHWB1" < "DLTHWB2"; ["DLTHWB1" + "DLHYSTWB1" < "DLTHWB2" + "DLHYSTWB2". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DMDUA Down MDU A BSC6900 ADD BTSANTFEEDERBRD(Optional)SET BTSANTFEEDERCONNECT(Optional) MDU board number when the antenna pass of downlink tributary A is selected GBFD-111202O&M of BTS Interval Type 0~255 0~255 None None None BTS The setting of this parameter depends on "Board Type". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DMDUB Down MDU B BSC6900 ADD BTSANTFEEDERBRD(Optional)SET BTSANTFEEDERCONNECT(Optional) MDU board number when the antenna pass of downlink tributary B is selected GBFD-111202O&M of BTS Interval Type 0~255 0~255 None None None BTS The setting of this parameter depends on "Board Type". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DN Domain BSC6900 SET BTSIPCLKPARA(Mandatory) Clock domain required by the slave side in the 1588V2 protocol. This parameter is valid when the 1588CLK type is configured. GBFD-118620Clock over IP support 1588V2 Interval Type 0~255 0~255 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DNDEFAULTCS Downlink Default CS Type BSC6900 SET GCELLPSCS(Optional) Coding scheme of the default GPRS downlink. Dynamic adjustment coding: the coding scheme used during initial access transmission. If the downlink uses the fixed coding scheme, the TBF uses the fixed coding scheme. GBFD-119106Coding Scheme Enumeration Type CS1(CS1), CS2(CS2), CS3(CS3), CS4(CS4) CS1, CS2, CS3, CS4 None None CS2 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DNDEFAULTMCS Downlink Default MCS Type BSC6900 SET GCELLEGPRSPARA(Optional) Default coding scheme of the downlink EDGE link. If the downlink adopts the dynamic adjustment coding scheme, this parameter can be used to set the coding scheme for transmission during initial access. If the downlink uses the fixed coding scheme, the TBF uses the fixed coding scheme. GBFD-114201EGPRS Enumeration Type MCS1(MCS1), MCS2(MCS2), MCS3(MCS3), MCS4(MCS4), MCS5(MCS5), MCS6(MCS6), MCS7(MCS7), MCS8(MCS8), MCS9(MCS9) MCS1, MCS2, MCS3, MCS4, MCS5, MCS6, MCS7, MCS8, MCS9 None None MCS6 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DNE2ADEFAULTMCS Downlink EGPRS2-A Default MCS Type BSC6900 SET GCELLEGPRSPARA(Optional) Default coding scheme used on the downlink EGPRS2-A link. If the downlink uses the dynamic coding scheme, this parameter specifies the coding scheme that is used for the transmission in initial access. If the downlink uses the fixed coding scheme, the TBF uses the fixed coding scheme. GBFD-510804Downlink EGPRS2-A Enumeration Type MCS1(MCS1), MCS2(MCS2), MCS3(MCS3), MCS4(MCS4), MCS7(MCS7), MCS8(MCS8), DAS5(DAS5), DAS6(DAS6), DAS7(DAS7), DAS8(DAS8), DAS9(DAS9), DAS10(DAS10), DAS11(DAS11), DAS12(DAS12) MCS1, MCS2, MCS3, MCS4, MCS7, MCS8, DAS5, , DAS6, DAS7, DAS8, DAS9, DAS10, DAS11, DAS12 None None DAS6 Cell This parameter is valid only when "EGPRS2A" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DNE2AFIXMCS Downlink EGPRS2-A Fixed MCS Type BSC6900 SET GCELLEGPRSPARA(Optional) Fixed coding scheme that is used on the downlink EGPRS2-A link. If the downlink uses the fixed coding scheme, this parameter can be set MSC1-4, MSC7-8 or DAS5-12.. If the downlink uses the dynamic coding scheme, this parameter is set to UNFIXED. GBFD-510804Downlink EGPRS2-A Enumeration Type MCS1(MCS1), MCS2(MCS2), MCS3(MCS3), MCS4(MCS4), MCS7(MCS7), MCS8(MCS8), DAS5(DAS5), DAS6(DAS6), DAS7(DAS7), DAS8(DAS8), DAS9(DAS9), DAS10(DAS10), DAS11(DAS11), DAS12(DAS12), UNFIXED(UNFIXED) MCS1, MCS2, MCS3, MCS4, MCS7, MCS8, DAS5, , DAS6, DAS7, DAS8, DAS9, DAS10, DAS11, DAS12, UNFIXED None None UNFIXED Cell This parameter is valid only when "EGPRS2A" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DNFIXCS Downlink Fixed CS Type BSC6900 SET GCELLPSCS(Optional) Adjustment mode of the downlink GPRS link coding scheme. If the fixed coding scheme is used, this parameter is set to a value ranging from CS1 to CS4. If the dynamic coding scheme is used, this parameter is set to UNFIXED. GBFD-119106Coding Scheme Enumeration Type CS1(CS1), CS2(CS2), CS3(CS3), CS4(CS4), UNFIXED(UNFIXED) CS1, CS2, CS3, CS4, UNFIXED None None UNFIXED Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DNFIXMCS Downlink Fixed MCS Type BSC6900 SET GCELLEGPRSPARA(Optional) Coding scheme of the downlink EDGE link. If the downlink uses the fixed coding scheme, this parameter is set to a value ranging from MCS1 to MCS9. If the downlink uses the dynamic adjustment coding scheme, this parameter is set to UNFIXED. GBFD-114201EGPRS Enumeration Type MCS1(MCS1), MCS2(MCS2), MCS3(MCS3), MCS4(MCS4), MCS5(MCS5), MCS6(MCS6), MCS7(MCS7), MCS8(MCS8), MCS9(MCS9), UNFIXED(UNFIXED) MCS1, MCS2, MCS3, MCS4, MCS5, MCS6, MCS7, MCS8, MCS9, UNFIXED None None UNFIXED Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DNPCEN DL PC Allowed BSC6900 SET GCELLBASICPARA(Optional) Whether to allow power adjustment for a BTS GBFD-110703GBFD-117601 Enhanced Power Control AlgorithmHUAWEI III Power Control Algorithm Enumeration Type NO(No), YES(Yes)NO, YES None None YES Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The downlink power control (at the BTS side) can support up to 15 levels, in each of which the power of 2 dB is dynamically controlled.
DNSENDSMDIS Short Message Downlink Disabled BSC6900 SET GCELLCCAD(Optional) Whether to prohibit sending point-to-point short messages. If necessary, this parameter is used for controlling whether to send downlink short messages from a specific cell so as to ensure sufficient radio channel resources for normal calls. GBFD-110203Point To Point Short Message Service (TS21, TS22) Enumeration Type NO(No), YES(Yes)NO, YES None None NO Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved During upgrade, pay more attention to the setting of this parameter. Be sure to check it. If an area is allowed for receiving short messages, set this parameter to NO.If the value of this parameter is YES, the MS in either idle or connected mode cannot occupy radio channel resources to send short messages.
DNTBFRELDELAY Release Delay of Downlink TBF BSC6900 SET GCELLPRIVATEOPTPARA(Optional) Delay of releasing the downlink TBF. After the last downlink RLC data block is transmitted on the network side and all the transmitted downlink data blocks are received, the MS is not informed to stop this downlink TBF. Instead, the state of the last data block is forcibly set to "not received" and the RRBP flag of the last data block is retransmitted continuously so that the downlink TBF is not released. During the downlink delay release, if the upper layer of the network side needs to transmit downlink data, the downlink RLC block for unpacking can be transmitted in the downlink TBF for delay release. The state of the downlink TBF is changed from delay releasing to downlink transmitting. In addition, the MS must respond the Packet Downlink Ack/Nack message through the uplink data block of the RRBP to exchange messages with the network side. When the MS needs to send data, the MS can send the uplink request to the network sides through the Packet Downlink Ack/Nack with the channel request description. If thi GBFD-114101GPRS Interval Type 0~5000 0~5000 ms None 2400 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DNTHDCSDEGRADE1 Downlink TBF Threshold from CS2 to CS1 BSC6900 SET GCELLPSCS(Optional) Retransmission threshold when the coding mode of the downlink TBF is changed from CS2 to CS1. When the downlink TBF retransmission rate is greater than or equals to this value, the coding mode of the TBF is changed from CS2 to CS1. GBFD-119106Coding Scheme Interval Type 0~64 0~64 per cent None 10 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DNTHDCSDEGRADE2 Downlink TBF Threshold from CS3 to CS2 BSC6900 SET GCELLPSCS(Optional) Retransmission threshold when the coding mode of the TBF is changed from CS3 to CS2. When the TBF retransmission rate is greater than or equals to this value, the coding mode of the TBF is changed from CS3 to CS2. GBFD-118901CS-3/CS-4 Interval Type 0~64 0~64 per cent None 5 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DNTHDCSDEGRADE3 Downlink TBF Threshold from CS4 to CS3 BSC6900 SET GCELLPSCS(Optional) Retransmission threshold when the coding mode of the downlink TBF is changed from CS4 to CS3. When the downlink TBF Retransmission rate is greater than or equals to this value, the coding mode of the TBF is changed from CS4 to CS3. GBFD-118901CS-3/CS-4 Interval Type 0~64 0~64 per cent None 5 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DNTHDCSUPGRADE1 Downlink TBF Threshold from CS1 to CS2 BSC6900 SET GCELLPSCS(Optional) Retransmission threshold when the coding mode of the downlink TBF is changed from CS1 to CS2. When the TBF retransmission rate is less than or equals to this value, the coding mode of the TBF is changed from CS1 to CS2. GBFD-119106Coding Scheme Interval Type 0~64 0~64 per cent None 5 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DNTHDCSUPGRADE2 Downlink TBF Threshold from CS2 to CS3 BSC6900 SET GCELLPSCS(Optional) Retransmission threshold when the coding mode of the TBF is changed from CS2 to CS3. When the downlink TBF retransmission rate is less than or equals to CS2 to CS1, the coding mode of the TBF is changed from CS2 to CS3. GBFD-118901CS-3/CS-4 Interval Type 0~64 0~64 per cent None 2 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DNTHDCSUPGRADE3 Downlink TBF Threshold from CS3 to CS4 BSC6900 SET GCELLPSCS(Optional) Retransmission threshold when the coding mode of the downlink TBF is changed from CS3 to CS4. When the downlink TBF retransmission rate is less than or equals to this value, the coding mode of the downlink TBF is changed from CS3 to CS4. GBFD-118901CS-3/CS-4 Interval Type 0~64 0~64 per cent None 2 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DOOR_ENGINE_MASK Enable Door Status Alarm Reporting BSC6900 ADD EMU(Optional) Door status alarm switch MRFD-210304Faulty Management Enumeration Type CLOSE(Close), OPEN(Open) CLOSE, OPEN None OPEN None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DOUBLEANTENNAGAIN Double Antenna Gain BSC6900 SET GCELLPWRBASIC(Optional) Dual-antenna gain used to estimate the downlink power during assignment GBFD-117602Active Power Control Interval Type 0~255 0~255, step:0.1 dB None None Cell This parameter is valid only when "PWRBCDALLOWD" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved If you do not use a dual-antenna to receive signals, set this parameter to 0.
DPC DSP code[Whole Number] BSC6900 ADD N7DPC(Mandatory) As a whole number, the DSP code can be expressed by a decimal digit or a hexadecimal digit. If the DSP code is expressed by a hexadecimal digit, H' is added before the number. None None Interval Type 1~16777215 1~16383(BIT14), 1~65535(BIT16), 1~16777215(BIT24) None None None SCCP When the value of "SPDF" in "ADD N7DPC" is set to DNF, this parameter is valid. Read & Write Y BSC6900 Less than 10 minutes None
DPCDNF DSP code[Divided Number] BSC6900 ADD N7DPC(Mandatory) The input format of the DSP is the divided segment, like 8-8-8. None None String Type None 1~11 characters None None None SCCP None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
DPCGIDX DPC Group Index BSC6900 BLK ACIC(Mandatory) It is one key field of identifying the block of A interface CIC status and indicates the DPC group index of the circuit ID of the A interface to be blocked. GBFD-111803A Interface Circuit Management Interval Type 0~31 0~31 None None None E1/T1 linkNone Read & Write N (No impact on the UE in idle mode) Not involved Not involved 1. The block of A interface must be configured. 2. If A over IP is configured, the configuration does not support the operation.
DPCGIDX DPC Group Index BSC6900 ADD AE1T1(Optional) DPC group index GBFD-111803A Interface Circuit Management Interval Type 0~31 0~31 None 0 0 E1/T1 linkNone Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DPCGIDX DPC Group Index BSC6900 ADD GCNNODE(Mandatory) Signaling group of a DSP.If multiple DSPs or one DSP serves as a logical entity, this logical entity is a DSP group. GBFD-117401MSC Pool Interval Type 0~31 0~31 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DPCT DSP type BSC6900 ADD N7DPC(Mandatory) DSP type. IUCS: indicates the IU interface CS control plane and user plane signaling point. IUPS: indicates the signaling point of the IU interface PS control signaling plane. IUR: indicates the RNC signaling point. IUCS_ALCAP: indicates the signaling point of the IU interface CS user signaling plane. IUCS_RANAP: indicates the signaling point of the IU interface CS control plane. STP: indicates the signaling transfer point. AAL2SWITCH: indicates the ATM switch.A indicates the signaling point of the A interface control signaling plane. IUR_G indicates the BSC signaling point. None None Enumeration Type IUCS(IUCS), IUPS(IUPS), IUR(IUR), IUCS_RANAP(IUCS_RANAP), IUCS_ALCAP(IUCS_ALCAP), AAL2SWITCH(AAL2SWITCH), STP(STP), A(A), IUR_G(IUR_G) IUCS, IUPS, IUR, IUCS_RANAP, IUCS_ALCAP, STP, AAL2SWITCH, A, IUR_G None None None SCCP None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
DPX DSP index BSC6900 ADD N7DPC(Mandatory)ADD MTP3RT(Mandatory)ADD MTP3LKS(Mandatory)ADD M3DE(Mandatory)ADD GCNNODE(Mandatory) The DSP index uniquely indicates the corresponding relationship of an DSP and OSP. None None Interval Type 0~182 0~182 None None None SCCP None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
DPX DPX Index BSC6900 ADD ADJNODE(Mandatory) It is valid when the node type is set to IUR, IUCS, IUPS, or NNI_AAL2SWITCH. None None Interval Type 0~182 0~182 None None None Adjacent node When the value of "NODET" in "ADD ADJNODE" is set to IUR, IUCS, or NNI_AAL2SWITCH, or the value of "NODET" in "ADD ADJNODE" is set to IUPS and "SGSNFLG" in "ADD ADJNODE" is set to YES, this parameter is valid. Read & Write Not involved Not involved Not involved The parameter cannot be modified.
DPX DPX BSC6900 ADD GNRNC(Mandatory) Iur-g DPC index of a neighboring RNC MRFD-211402MBSC Load Balancing Interval Type 0~182 {0~182} None None None BSC DPX of Iur-g type Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DRHOLEVRANGE Directed Retry Handover Level Range BSC6900 ADD G2GNCELL(Optional) Maximum signal level difference between the neighbor cell and the serving cell for triggering directed retry GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 0~128 0~128 dB None 72 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DROPCTRLABISCONNFAIL Drop Optimize ABIS Link Failure BSC6900 SET GCELLSOFT(Optional) Whether to optimize the call drops resulting from Abis territorial link fault. The value 0 means "optimize" and 1 means "not optimize". If the value of this parameter is 0, the call drops resulting from this cause are not brought into the statistics of call drops. GBFD-111004Radio Dedicated Channel Management Interval Type 0~1 0~1 None None 1 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DROPCTRLCONNFAILHOACCFAIL Drop Optimize Conn Fail[HO access fail] BSC6900 SET GCELLSOFT(Optional) Whether to optimize the call drops resulting from connection failure (handover access failure). The value 0 means "optimize" and 1 means "not optimize". If the value of this parameter is 0, the call drops resulting from this cause are not brought into the statistics of call drops. GBFD-111004Radio Dedicated Channel Management Interval Type 0~1 0~1 None None 1 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DROPCTRLCONNFAILOM Drop Optimize Conn Fail[OM intervention] BSC6900 SET GCELLSOFT(Optional) Whether to optimize the call drops resulting from connection failure, operation and maintenance (OM) intervention. The value 0 means "optimize" and 1 means "not optimize". If the value of this parameter is 0, the call drops resulting from this cause are not brought into the statistics of call drops. GBFD-111004Radio Dedicated Channel Management Interval Type 0~1 0~1 None None 1 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DROPCTRLCONNFAILOTHER Drop Optimize Conn Fail[other] BSC6900 SET GCELLSOFT(Optional) Whether to optimize the call drops resulting from a connection failure except for handover access failure, OM intervention, radio link failure, and unavailability of radio resources. The value 0 means "optimize" and 1 means "not optimize". If the value of this parameter is 0, the call drops resulting from this cause are not brought into the statistics of call drops. GBFD-111004Radio Dedicated Channel Management Interval Type 0~1 0~1 None None 1 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DROPCTRLCONNFAILRLFAIL Drop Optimize Conn Fail[radio link fail] BSC6900 SET GCELLSOFT(Optional) Whether to optimize the call drops resulting from connection failure (radio link failure). The value 0 means "optimize" and 1 means "not optimize". If the value of this parameter is 0, the call drops resulting from this cause are not brought into the statistics of call drops. GBFD-111004Radio Dedicated Channel Management Interval Type 0~1 0~1 None None 1 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DROPCTRLCONNFAILRRNOTAVL Drop Optimize Conn Fail[resource not available] BSC6900 SET GCELLSOFT(Optional) Whether to optimize the call drops resulting from connection failure (unavailability of radio resources). The value 0 means "optimize" and 1 means "not optimize". If the value of this parameter is 0, the call drops resulting from this cause are not brought into the statistics of call drops. GBFD-111004Radio Dedicated Channel Management Interval Type 0~1 0~1 None None 1 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DROPCTRLEQUIPFAIL Drop Optimize Equipment Failure BSC6900 SET GCELLSOFT(Optional) Whether to optimize the call drops resulting from equipment fault. The value 0 means "optimize" and 1 means "not optimize". If the value of this parameter is 0, the call drops resulting from this cause are not brought into the statistics of call drops. GBFD-111004Radio Dedicated Channel Management Interval Type 0~1 0~1 None None 1 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DROPCTRLERRINDDMRSP Drop Optimize Err Ind[unsolicited DM response] BSC6900 SET GCELLSOFT(Optional) Whether to optimize the call drops resulting from error indication (unsolicited DM response). The value 0 means "optimize" and 1 means "not optimize". If the value of this parameter is 0, the call drops resulting from this cause are not brought into the statistics of call drops. GBFD-111004Radio Dedicated Channel Management Interval Type 0~1 0~1 None None 1 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DROPCTRLERRINDSEQERR Drop Optimize Err Ind[sequence error] BSC6900 SET GCELLSOFT(Optional) Whether to optimize the call drops resulting from error indication (sequence error). The value 0 means "optimize" and 1 means "not optimize". If the value of this parameter is 0, the call drops resulting from this cause are not brought into the statistics of call drops. GBFD-111004Radio Dedicated Channel Management Interval Type 0~1 0~1 None None 1 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DROPCTRLERRINDT200 Drop Optimize Err Ind[T200 timeout] BSC6900 SET GCELLSOFT(Optional) Whether to optimize the call drops resulting from error indication (T200 timeout). The value 0 means "optimize" and 1 means "not optimize". If the value of this parameter is 0, the call drops resulting from this cause are not brought into the statistics of call drops. GBFD-111004Radio Dedicated Channel Management Interval Type 0~1 0~1 None None 1 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DROPCTRLFORCHOFAIL Drop Optimize Forced Handover Failure BSC6900 SET GCELLSOFT(Optional) Whether to optimize the call drops resulting from forced handover failure. The value 0 means "optimize" and 1 means "not optimize". If the value of this parameter is 0, the call drops resulting from this cause are not brought into the statistics of call drops. GBFD-111004Radio Dedicated Channel Management Interval Type 0~1 0~1 None None 1 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DROPCTRLINBSCHO Drop Optimize Into-BSC Handover Timeout BSC6900 SET GCELLSOFT(Optional) Whether to optimize the call drops resulting from incoming-BSC handover timeout. The value 0 means "optimize" and 1 means "not optimize". If the value of this parameter is 0, the call drops resulting from this cause are not brought into the statistics of call drops. GBFD-111004Radio Dedicated Channel Management Interval Type 0~1 0~1 None None 1 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DROPCTRLINTRABSCOUTHO Drop Optimize Intra-BSC Handover Timeout BSC6900 SET GCELLSOFT(Optional) Whether to optimize the call drops resulting from outgoing internal inter-cell handover timeout. The value 0 means "optimize" and 1 means "not optimize". If the value of this parameter is 0, the call drops resulting from this cause are not brought into the statistics of call drops. GBFD-111004Radio Dedicated Channel Management Interval Type 0~1 0~1 None None 1 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DROPCTRLINTRACELLHO Drop Optimize Intra-Cell Handover Timeout BSC6900 SET GCELLSOFT(Optional) Whether to optimize the call drops resulting from intra-cell handover timeout. The value 0 means "optimize" and 1 means "not optimize". If the value of this parameter is 0, the call drops resulting from this cause are not brought into the statistics of call drops. GBFD-111004Radio Dedicated Channel Management Interval Type 0~1 0~1 None None 1 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DROPCTRLNOMR Drop Optimize No MR for Long Time BSC6900 SET GCELLSOFT(Optional) Whether to optimize the call drops resulting from no MS measurement reports for a long time. The value 0 means "optimize" and 1 means "not optimize". If the value of this parameter is 0, the call drops resulting from this cause are not brought into the statistics of call drops. GBFD-111004Radio Dedicated Channel Management Interval Type 0~1 0~1 None None 1 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DROPCTRLOUTBSCHOT8 Drop Optimize Out-BSC Handover Timeout BSC6900 SET GCELLSOFT(Optional) Whether to optimize the call drops resulting from outgoing-BSC handover timeout. The value 0 means "optimize" and 1 means "not optimize". If the value of this parameter is 0, the call drops resulting from this cause are not brought into the statistics of call drops. GBFD-111004Radio Dedicated Channel Management Interval Type 0~1 0~1 None None 1 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DROPCTRLRELIND Drop Optimize Release Indication BSC6900 SET GCELLSOFT(Optional) Whether to optimize the call drops resulting from release indications. The value 0 means "optimize" and 1 means "not optimize". If the value of this parameter is 0, the call drops resulting from this cause are not brought into the statistics of call drops. GBFD-111004Radio Dedicated Channel Management Interval Type 0~1 0~1 None None 1 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DROPCTRLRESCHK Drop Optimize Resource Check BSC6900 SET GCELLSOFT(Optional) Whether to optimize the call drops resulting from resource check. The value 0 means "optimize" and 1 means "not optimize". If the value of this parameter is 0, the call drops resulting from this cause are not brought into the statistics of call drops. GBFD-111004Radio Dedicated Channel Management Interval Type 0~1 0~1 None None 1 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DROPPKTTHD0 Packet discard threshold of queue 0 [ms] BSC6900 ADD PORTFLOWCTRLPARA(Optional) If the duration for buffering the data in queue 0 is more than or equals to the value of this parameter, the subsequent packets added to queue 0 are discarded. For the flow control adopting the ATM, this parameter indicates the threshold for discarding packets in the CBR queue. None None Interval Type 10~150 10~150 ms 60 IP:60; ATM:45 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter can be added and modified. It cannot be deleted.
DROPPKTTHD1 Packet discard threshold of queue 1 [ms] BSC6900 ADD PORTFLOWCTRLPARA(Optional) If the duration for buffering the data in queue 1 is more than or equals to the value of this parameter, the subsequent packets added to queue 1 are discarded. For the flow control adopting the ATM, this parameter indicates the threshold for discarding packets in the RTVBR queue. None None Interval Type 10~150 10~150 ms 60 IP:60; ATM:45 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter can be added and modified. It cannot be deleted.
DROPPKTTHD2 Packet discard threshold of queue 2 [ms] BSC6900 ADD PORTFLOWCTRLPARA(Optional) If the duration for buffering the data in queue 2 is more than or equals to the value of this parameter, the subsequent packets added to queue 2 are discarded. For the flow control adopting the ATM, this parameter indicates the threshold for discarding packets in the NRTVBR queue. None None Interval Type 10~150 10~150 ms 60 IP:60; ATM:45 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter can be added and modified. It cannot be deleted.
DROPPKTTHD3 Packet discard threshold of queue 3 [ms] BSC6900 ADD PORTFLOWCTRLPARA(Optional) If the duration for buffering the data in queue 3 is more than or equals to the value of this parameter, the subsequent packets added to queue 3 are discarded. For the flow control adopting the ATM, this parameter indicates the threshold for discarding packets in the UBR queue. None None Interval Type 10~150 10~150 ms 60 IP:60; ATM:80 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter can be added and modified. It cannot be deleted.
DROPPKTTHD4 Packet discard threshold of queue 4 [ms] BSC6900 ADD PORTFLOWCTRLPARA(Optional) If the duration for buffering the data in queue 4 is more than or equals to the value of this parameter, the subsequent packets added to queue 4 are discarded. For the flow control adopting the ATM, this parameter indicates the threshold for discarding packets in the UBR+ queue. None None Interval Type 10~150 10~150 ms 80 80 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter can be added and modified. It cannot be deleted.
DROPPKTTHD5 Packet discard threshold of queue 5 [ms] BSC6900 ADD PORTFLOWCTRLPARA(Optional) If the duration for buffering the data in queue 5 is more than or equals to the value of this parameter, the subsequent packets added to queue 5 are discarded. None None Interval Type 10~150 10~150 ms 80 80 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter can be added and modified. It cannot be deleted.
DROPPWRINTERVAL Drop Power Time Interval[T3] BSC6900 SET BTSBAKPWR(Optional) Interval at which the BTS decreases the power of a TRX continuously GBFD-111605Active Backup Power Control Interval Type 1~60 1~60 min None 10 BTS This parameter is valid only when "BAKPWRSAVMETHOD" is set to BYPWR. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DROPPWRSTARTTIME Drop Power Start Time[T1] BSC6900 SET BTSBAKPWR(Optional) Delay for which the BTS waits to decrease the power of a TRX after switching from the mains to batteries GBFD-111605Active Backup Power Control Interval Type 0~12 0~12 h None 3 BTS This parameter is valid only when "BAKPWRSAVMETHOD" is set to BYPWR. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DROPPWRSTEP Drop Power Step BSC6900 SET BTSBAKPWR(Optional) Step by which the BTS decreases the power of a TRX at one time GBFD-111605Active Backup Power Control Interval Type 2~10 2~10 dB None 2 BTS This parameter is valid only when "BAKPWRSAVMETHOD" is set to BYPWR. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DRXEN SMCBC DRX BSC6900 SET GCELLOTHEXT(Optional) Whether to support the discontinuous reception mechanism (DRX). To reduce the power consumption, the DRX is introduced into the GSM Specification. MSs supporting the DRX can consume less power to receive interested broadcast messages. This prolongs the service time of MS batteries.BSCs supporting the DRX must send scheduling messages to MSs so that the MSs can use the DRX function. The period occupied by broadcast messages that are contained in a scheduling message is called a scheduling period. In the sending sequence, a scheduling message contain the description of each short message to be broadcasted and the position of each broadcast message in the scheduling period. GBFD-113602Simplified Cell Broadcast Enumeration Type NO(No), YES(Yes)NO, YES None None YES Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DRXTIMERMAX Max. Duration of DRX BSC6900 SET GCELLPSBASE(Optional) Duration of the timer for entering the DRX mode. DRX is the parameter in the cell broadcast message. It indicates non-continuous receiving mode. When the MS is switched from the packet transmission mode to the idle mode, the MS needs to maintain the none DRX mode for a moment. After the TBF is released, in the period when the MS is in non-DRX mode, the MS monitors all the CCCH blocks and the BSC stores the context of the MS. The reservation duration is determined by the minimum value of DRX_Timer_Max and NON_DRX_TIMER. The parameter NON_DRX_TIMER is negotiated with the SGSN during GPRS attaching of the MS. Normally, this value is greater than that of DRX_TIMER_MAX. Therefore, the value of DRX_TIMER_MAX is used. 0: switch to the DRX mode immediately; 1: switch to the DRX mode in one second.Value n indicates that the MS enters the DRX mode n seconds later. GBFD-114802Discontinuous Reception (DRX) Enumeration Type 0(0), 1(1), 2(2), 4(4), 8(8), 16(16), 32(32), 64(64) 0, 1, 2, 4, 8, 16, 32, 64s None 4 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DRYSET Dehumidification Equipment BSC6900 SET BTSOUTPUT(Optional) Whether to start the dehumidification equipment of the BTS.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. GBFD-111202O&M of BTS Enumeration Type INACTIVE(Inactive), ACTIVE(Active) INACTIVE, ACTIVE None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DS1 E1T1 port No. BSC6900 ADD PPPLNK(Optional) Number of the E1T1 port for bearing the PPP link GBFD-118611GBFD-118622 Abis IP over E1/T1A IP over E1/T1 Interval Type 0~335 0~335 None None None PPP link None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
DS1 E1T1 port No. BSC6900 ADD MPLNK(Optional) Number of the E1T1 port for bearing the PPP link GBFD-118611GBFD-118622 Abis IP over E1/T1A IP over E1/T1 Interval Type 0~335 0~335 None None None MP link None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DSCP Differentiated Service Codepoint BSC6900 ADD SCTPLNK(Optional)SET PHBMAP(Mandatory) The DSCP is a field of the IP data packet. It is used to assign the differentiated service to the communication networks. The DSCP code is used to label each data packet on the network and allocate the corresponding service levels. In the same network environment, the larger the DSCP is, the higher the priority is. None None Interval Type 0~63 0~63 None 62 62 SCTP linkNone Read & Write N (No impact on the UE in idle mode) Not involved Not involved The priority of the signaling link should be the highest.
DSCP Differentiated services code point BSC6900 PING IP(Optional) Service code of the PING command, used to identify the PING command None None Interval Type 0~63 0~63 None 0 0 Ethernet port None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
DSCP Differentiated Service Codepoint BSC6900 SET DSCPMAP(Mandatory) Differentiated service code is used to identify the service priority of the user. None None Interval Type 0~63 0~63 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The existing networking can be affected when the relation between the VLAN and the DSCP are reset.
DSCP DSCP BSC6900 SET BTSVLAN(Optional) DSCP to be contained in the header of an IP packet. According to this parameter, the router provides differentiated services for packet streams. If this parameter is greater, the service level is higher. This parameter is valid only when the transport type is set to IP. GBFD-118605IP QOS Interval Type 0~63 0~63 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DSPKIFFOFFTIMER DSP Kickoff Timer BSC6900 SET BSCPSSOFTPARA(Optional) Duration for recovering all the DSPs. This timer is started when the first DSP is recovered. When all the DSPs of the local subrack are recovered or the timer expires, the timer is stopped. The cells are distributed on the recovered DSPs. GBFD-114101GPRS Interval Type 1~3600 1~3600 s None 180 BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DSPN DSP No. BSC6900 DLD TCFILE(Mandatory) Number of the DSP. For the DPUa, DPUb, DPUc, or DPUd, the value range of "DSP No." is from "0" to "21". For the DPUe, the value range of "DSP No." is from "0" to "27". If you do not specify this parameter, the usage of all DSPs is queried. MRFD-210301Configuration Management Interval Type 0~27 0~27 None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DSPN DSP No. BSC6900 ADD OBJALMSHLD(Mandatory) Number of the DSP where the alarm is generated MRFD-210304Faulty Management Interval Type 0~21 0~21 None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DSPN DSP No. BSC6900 SET TCPLYVOICE(Mandatory)SET TCPARA(Optional) Number of the DSP in the DPU board MRFD-210301Configuration Management Interval Type 0~21 0~21 None None None Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved If "Play switch" in the "SET TCPLYVOICE" command is set, the normal calls may be affected.
DSPNO DSP No. BSC6900 SET PSCELLTODSP(Mandatory) Target DSP number. GBFD-114101GPRS Interval Type 0~21 0~21 None None None BSC This parameter is valid only when "IDXTYPE" is set to BYCELL. Read & Write Y Cell Less than 5 minutes None
DSPRECOVERTIMER DSP Recover Timer BSC6900 SET BSCPSSOFTPARA(Optional) DSP recover time during cell reallocation. When the DSP failure is detected, the timer is started. The system waits for DSP failure recovery before the timer expires. If the DSP failure is recovered or the timer expires, the timer is stopped and the cell reallocation is implemented. GBFD-114101GPRS Interval Type 0~30 0~30 s None 15 BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DST DaylightSave BSC6900 SET TZ(Optional) Whether daylight saving time starts MRFD-210301Configuration Management Enumeration Type NO(NO), YES(YES) YES, NO None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DSTF Destination File Name BSC6900 ULD BTSDEVFILE(Mandatory) Name of the destination file GBFD-111202O&M of BTS String Type None 1~128 characters None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DSTIP Destination IP address BSC6900 ADD IPRT(Mandatory) Destination IP address None None IP Address Type None 0.0.0.0~255.255.255.255 None None None IP route None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
DSTIP Destination IP address BSC6900 ADD BTSBFD(Mandatory) Destination IP address of BFD Session. GBFD-118609IP Fault Detection Based on BFD IP Address Type None 0.0.0.0~255.255.255.255 None None None Current BFD session None Read & Write Not involved Not involved Not involved None
DSTIP Destination IP address BSC6900 ADD BTSIPRT(Mandatory)ADD BTSIPRTBIND(Mandatory) Destination IP address GBFD-118601Abis over IP IP Address Type None 0.0.0.0~255.255.255.255 None None None IP route None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DSTMASK Destination address mask BSC6900 ADD IPRT(Mandatory) Subnet mask None None IP Address Type None 0.0.0.0~255.255.255.255 None None None IP route None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
DSTMASK Destination address mask BSC6900 ADD BTSIPRT(Mandatory)ADD BTSIPRTBIND(Mandatory) Subnet mask GBFD-118601Abis over IP IP Address Type None 0.0.0.0~255.255.255.255 None None None IP route None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DSTPORTNO Destination port No. BSC6900 ADD TSCROSS(Mandatory) Destination of timeslot cross None None Interval Type 0~335 0~335 None None None E1/T1 port None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DSTTSMASK Destination timeslot mask BSC6900 ADD TSCROSS(Mandatory) Target timeslot mask None None Bit Field Type TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10, TS11, TS12, TS13, TS14, TS15, TS16, TS17, TS18, TS19, TS20, TS21, TS22, TS23, TS24, TS25, TS26, TS27, TS28, TS29, TS30, TS31 TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10, TS11, TS12, TS13, TS14, TS15, TS16, TS17, TS18, TS19, TS20, TS21, TS22, TS23, TS24, TS25, TS26, TS27, TS28, TS29, TS30, TS31 None None None E1/T1 port None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DTLOADTHRED Directed Retry Load Access Threshold BSC6900 SET GCELLCCBASIC(Optional) Threshold of the load in the target cell for the directed retry. Only a cell whose load is lower than or equal to this threshold can be selected as a candicate target cell. GBFD-110607Direct Retry Interval Type 0~100 0~100 per cent None 85 Cell The value of DTLOADTHRED must be set when "REASSEN" in the "SET GCELLBASICPARA" command is set to DIRECTRYEN. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DTRTYPE DRX Type BSC6900 SET GCELLGSMR(Optional) Type of the DRX supporting the VGCS service. An MS reads the NCH only when a new notification message of group call arrives. This helps save power of the MS. This parameter is mandatory for a SAGEM MS. GBFD-510301Public Voice Group Call Service Enumeration Type NO(No), YES(Yes)NO, YES None None YES Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DTRX Down Link No. BSC6900 ADD BTSANTFEEDERBRD(Mandatory) Downlink TRX index number of the newly added board GBFD-111202O&M of BTS Interval Type 1~12 1~12 None None None BTS The setting of this parameter depends on "Board Type". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DTRX Down Link No. BSC6900 SET BTSANTFEEDERCONNECT(Optional) Index number of the downlink tributary GBFD-111202O&M of BTS Enumeration Type 1(1), 2(2), 3(3), 4(4), 5(5), 6(6), 7(7), 8(8), 9(9), 10(10), 11(11), 12(12) 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DTRXPN Down TRX Board Pass No. BSC6900 ADD BTSANTFEEDERBRD(Optional) TRX board pass number connected with the downlink tributary GBFD-111202O&M of BTS Interval Type 0~1 0, 1 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DTRXPN Down TRX Board Pass No. BSC6900 SET BTSANTFEEDERCONNECT(Optional) TRX board pass number connected with the downlink tributary GBFD-111202O&M of BTS Interval Type 0~1,255 0~1, 255 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DTRXSN Down TRX Slot No. BSC6900 ADD BTSANTFEEDERBRD(Mandatory) Number of the slot where the TRX board that connects to downlink tributary is located GBFD-111202O&M of BTS Interval Type 0~23 0~23 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DTRXSN Down TRX Slot No. BSC6900 SET BTSANTFEEDERCONNECT(Optional) Number of the slot where the TRX board that connects to downlink tributary is located GBFD-111202O&M of BTS Interval Type 0~23,255 0~23, 255 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
5/5/2014
Confidential Information of Huawei.
No Spreading without Permission
Page7of42
226347869.xls.ms_office Security Level:
DTRXSRN Down TRX Subrack No. BSC6900 ADD BTSANTFEEDERBRD(Mandatory) Number of the subrack where the TRX board that connects to downlink tributary is located GBFD-111202O&M of BTS Interval Type 0~53 0~53 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DTRXSRN Down TRX Subrack No. BSC6900 SET BTSANTFEEDERCONNECT(Optional) Number of the subrack where the TRX board that connects to downlink tributary is located GBFD-111202O&M of BTS Interval Type 0~53,255 0~53, 255 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DUMMYBITRANDSWITCH Dummy Bit Randomization Switch BSC6900 SET GCELLSOFT(Optional) Whether a BTS randomizes the dummy bits (0x2B) in all the signaling messages that the BTS sends to an MS GBFD-113521Encrypted Network Management Enumeration Type OFF(Off), ON(On) OFF, ON None None OFF Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DUPLEX Duplex mode BSC6900 SET BTSETHPORT(Optional) Duplex mode GBFD-118601Abis over IP Enumeration Type FULL(FULL), HALF(HALF) FULL, HALF None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DURATH Duration Hour BSC6900 STR BTSTST(Mandatory) Duration for starting the BTS test GBFD-111207BTS Test Function Interval Type 0~12 0~12 h None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DURATH Duration Hour BSC6900 STR TRXBURSTTST(Mandatory) Duration for starting the TRX idle timeslot test GBFD-111207BTS Test Function Interval Type 1~24 1~24 h None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DURATM Duration Minute BSC6900 STR BTSTST(Mandatory) Duration for starting the BTS test GBFD-111207BTS Test Function Interval Type 0~59 0~59 min None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DURATS Duration Second BSC6900 STR BTSTST(Mandatory) Duration for starting the TRX idle timeslot test GBFD-111207BTS Test Function Interval Type 0~59 0~59 s None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DWNDYNCHNTRANLEV Downlink Multiplex Threshold of Dynamic Channel Conversion BSC6900 SET GCELLPSCHM(Optional) Downlink multiplex threshold of dynamic channel conversion. When the subscriber number on the channel reaches the value (threshold/10), the dynamic channel conversion is triggered. GBFD-113101PDCH Dynamic Adjustment Interval Type 10~80 10~80 per cent None 20 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DWNINTEN DL Signal Strength Limit BSC6900 ADD AISSCFG(Optional) An MS can be used to test the Um interface software synchronization only when the DL signal strength after the power control compensation in the test cell and the observed cell is higher than this limit. GBFD-118201Soft-Synchronized Network Interval Type 0~63 0~63 None 20 None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None.
DXXINDEX Up DXX Index BSC6900 ADD BTSCONNECT(Mandatory) Number of a DXX. It is unique in one BSC and uniquely identifies a DXX. GBFD-111202O&M of BTS Interval Type 0~2047 0~2047 None None None BTS None Read & Write Y BTS Less than 5 minutes This parameter can be modified only when the BTS is deactivated.
DXXINDEX DXX Index BSC6900 ADD DXX(Mandatory)ADD DXXCONNECT(Mandatory)ADD DXXTSEXGRELATION(Mandatory) Number of a DXX. It is unique in one BSC and uniquely identifies a DXX. GBFD-111203O&M of BSC Interval Type 0~2047 0~2047 None None None BTS None Read & Write Y BTS Less than 5 minutes None
DXXPN Up DXX Port No. BSC6900 ADD BTSCONNECT(Mandatory) Number of the upper DXX port GBFD-111202O&M of BTS Interval Type 0~15 0~15 None None None BTS None Read & Write Y BTS Less than 5 minutes This parameter can be modified only when the BTS is deactivated.
DYNCHFREETM Timer of Releasing Idle Dynamic Channel BSC6900 SET GCELLPSCHM(Optional) Time to wait for releasing the dynamic channel after the TBF on the dynamic channel is released. When all the TBFs on the channel are released, the dynamic channel is not released at once. Instead, the timer is started when the channels are idle. Before the timer expires, if new service request is received, the dynamic channel is still occupied and timer is stopped; otherwise, the dynamic channel is released after the timer expired. GBFD-113101PDCH Dynamic Adjustment Interval Type 10~3600 10~3600 s None 20 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DYNCHNPREEMPTLEV Level of Preempting Dynamic Channel BSC6900 SET GCELLPSCHM(Optional) Mode of preempting the dynamic channel for the CS domain and PS domain. Only the channel configured in the TCH/F mode can be preempted. "Preempt all dynamic TCHFs" indicates the circuit domain can preempt all the dynamic channels. "No preempt of CCHs" indicates the circuit domain can preempt all the dynamic channels. "No preempt of service TCHF" indicates the circuit domain cannot preempt all the dynamic channels of bearer services. GBFD-113101PDCH Dynamic Adjustment Enumeration Type LEVEL0(Preempt all dynamic TCHFs), LEVEL1(No preempt of CCHs), LEVEL2(No preempt of service TCHF) LEVEL0, LEVEL1, LEVEL2 None None LEVEL0 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DYNCHTRANRESLEV Reservation Threshold of Dynamic Channel Conversion BSC6900 SET GCELLPSCHM(Optional) Number of full-rate TCHs reserved for the CS domain. This parameter is valid only when "Level of Preempting Dynamic Channel" is set to LEVEL1 or LEVEL2. GBFD-113101PDCH Dynamic Adjustment Interval Type 0~8 0~8 None None 2 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DYNOpenTrxPower Allow Dynamic Shutdown TRX BSC6900 SET GCELLBASICPARA(Optional) Whether to enable the function of dynamically switching off the TRX power amplifier GBFD-111602TRX Power Amplifier Intelligent Shutdown Enumeration Type NO(No), YES(Yes)NO, YES None None NO Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
DYNPBTSUPPORTED Dynamic Transmission Div Supported BSC6900 SET GCELLCHMGBASIC(Optional) Whether to enable the cell to support dynamic transmit diversity or dynamic PBT GBFD-118101Dynamic Transmit Diversity Enumeration Type NOTSUPPORT(Not Support), DDIVERSITY(DDIVERSITY), DPBT(DPBT) NOTSUPPORT, DDIVERSITY, DPBT None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
E1DURAT Duration BSC6900 STR TRANSPERFTST(Mandatory) Duration for the test in E1 mode GBFD-111203O&M of BSC Interval Type 1~60 1~60 min None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
E1PORT Port No. BSC6900 STR TRANSPERFTST(Mandatory) Number of the E1 port. For the BTS3012, BTS3012AE, and BTS3012 II, the number can be a value from 0 to 7. For other BTSs, the number can be a value from 0 to 3. GBFD-118601Abis over IP Interval Type 0~7 0~7 None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
E1PORTNOINBTSCONBSC E1 Port No Connect To BSC BSC6900 ADD BTSABISHDLCPATH(Mandatory) Number of the E1 port on the BTS connected to the BSC. GBFD-118401Abis Transmission Optimization Interval Type 0~31 0~31 None None None BTS None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
E1SLCTTMU TMU Type BSC6900 STR TRANSPERFTST(Mandatory) Type of the TMU GBFD-111207BTS Test Function Enumeration Type ACTIVE(ACTIVE TMU/MMU/IOMU/DOMU), ACTIVESTANDBY(ACTIVE/STANDBY TMU), SLAVE1(SLAVE TMU1/DOMU1), SLAVE2(SLAVE TMU2/DOMU2) ACTIVE, ACTIVESTANDBY, SLAVE1, SLAVE2 None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
E1T1PN E1/T1 port No. BSC6900 SET COPTLNK(Optional) E1/T1 port number None None Interval Type 0~83 0~83 None None None Channelized optical port None Read & Write N (No impact on the UE in idle mode) Not involved Not involved It is used for interworking with products of other manufacturers.
E1T1PN E1/T1 Port No. BSC6900 SET BTSCLK(Mandatory) Number of the E1/T1 port from which the BTS extracts the transport clock. This parameter is valid only when the clock type is set to IP_TRANSFER. MRFD-210501BTS/NodeB Clock Interval Type 0~7 0~7 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
E1T1PORTNO Backboard E1/T1 Port No BSC6900 ADD BTSTOPCONFIG(Mandatory) Number of the port extended by the backboard TOP communication mechanism of the BTS MRFD-211501IP-Based 2G/3G Co-Transmission on Base Station Side Interval Type 16~19 16~19 None None None BTS None Read & Write Y BTS Less than 5 minutes None
E1T1TYPE E1/T1 Type BSC6900 SET BTSCLK(Mandatory) Type of the E1/T1 from which the BTS extracts the transport clock. This parameter is valid only when the clock type is set to IP_TRANSFER. MRFD-210501BTS/NodeB Clock Enumeration Type E1(E1), T1(T1) E1, T1 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ECHOIP Check IP address BSC6900 ADD IPPATH(Mandatory) Check peer IP address. The input address (CHKIPADDR) must be the address (regardless of the network segment address or host address of the peer address) in the network segment specified by the (PEERIPADDR, PEERMASK). None None IP Address Type None 0.0.0.0~255.255.255.255 None None None IP path When the value of "PATHCHK" in "ADD IPPATH" is set to ENABLED, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved The address must exist and respond to the PING request.
ECNOOFF Ec/No Offset BSC6900 ADD G3GNCELL(Optional) As a performance counter for 3G cells, Ec/No indicates the ratio of the energy per received chip to the spectral noise power density.If the Ec/No of a 3G neighbor cell is greater than "HOECNOTH3G" plus this parameter, the neighbor cell is listed in the candidate cell queue. GBFD-114301GSM/WCDMA Interoperability Interval Type 0~49 0~49 dB None 3 Cell A 3G neighboring cell can be added into the candidate cell queue when the following conditions are met: "INTERRATOUTBSCHOEN" is set to YES; "BET3GHOEN" is set to YES; the Ec/No of the 3G neighboring cell for a period of time is greater than the sun of "HOECNOTH3G" and "ECNOOFF". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ECNOTHRES Ec/No threshold for layer Of 3G cell BSC6900 ADD GEXT3GCELL(Optional) Threshold for determining the layer of the 3G neighbor cell. If the Ec/No of the 3G neighbor cell is less than this threshold, the neighbor cell is set to the lowest layer (layer 5). GBFD-114301GSM/WCDMA Interoperability Interval Type 0~49 0~49 dB None 30 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ECSC ECSC BSC6900 SET GCELLCCBASIC(Optional) Early classmark sending control (ECSC). This parameter specifies whether the MSs in a cell use early classmark sending. For details, see GSM Rec. 04.08. After receiving a message about a classmark change, the MS sends additional classmark information to the network as early as possible. The CM3 (classmark 3) information contains the power information of each band of a multi-band MS. In an inter-band handover, the power level must be correctly described. When paging is made or the BA2 table is sent between different bands, the CM3 message must be known. GBFD-111101System Information Sending Enumeration Type NO(No), YES(Yes)NO, YES None None For a 900/1800 MHz CoBCCH cell, the recommended value is YES. For a 1800 MHz cell in the dual-band network, the recommended value is YES.If the A5/4-7 encryption algorithm is used, the recommended value is YES. Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ecsn End Serial No. BSC6900 EXP ALMLOG(Optional)STAALMLOG(Optional) End serial number of the alarm record MRFD-210304Faulty Management Interval Type 1~2147483646 1~2147483646 None 2147483646 2147483646 RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ED End Date BSC6900 ADD SUBTSK(Optional) Date when the scheduled task is stopped GBFD-111203O&M of BSC Compound Type year, month, date 2000-1-1~2037-12-31None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ed End Date BSC6900 EXP ALMLOG(Optional) End date of the alarm record. By default, the end date is 2038-12-31. MRFD-210304Faulty Management Compound Type year, month, day 2000-1-1~2037-12-31None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ed End Date BSC6900 STA ALMLOG(Optional) End date of the alarm record. By default, the end date is 2038-12-31. MRFD-210304Faulty Management Compound Type year, month, day 2000-1-1~2037-12-31None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
EDATE End Date BSC6900 STR BTSLOG(Optional) End date GBFD-111602TRX Power Amplifier Intelligent Shutdown Compound Type year, month, day 2000-01-01~2050-12-31 None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
EDAY End date BSC6900 SET TZ(Mandatory) End date of the daylight saving time MRFD-210301Configuration Management Interval Type 1~31 1~31 d None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved 1. If you set the start date or end date of daylight saving time (DST) to a day of the week after a specific date, the specific date must be six days or more days prior to the last day of the month. For example, the last day of October is the 31st day. Then, the specific date cannot be later than the 25th (31 6) day. If you set the specific date to Tuesday after 26 October, this date is not included in the November of 2005. Therefore, the specific date is invalid. This date in 2006, however, is October 31, which is valid. As a result, you must follow this principle to ensure that a specific data is always valid.2. You are not allowed to set the start date or end date of DST to February 29. This is because that the local time changes between the start date and end date of DST. In a non-leap year, February 29 does not exist. Therefore, the local time cannot change between DST and non-DST.3. The start month and end month of DST cannot be the same.
EDBLASTTIME Number of Satisfactory Measurements BSC6900 SET GCELLHOEDBPARA(Optional) According to the P/N rule, if the conditions for the handover between the subcells of an enhanced dual-frequency network are met during P of N measurements, the handover is triggered.This parameter specifies the number P. GBFD-114402Enhanced Dual-Band Network Interval Type 1~255 1~255 s None 4 Cell This parameter is valid only when "IUOTP" in "ADD GCELL" is set to EDB_cell. The following condition must be met: "EDBSTATTIME" >= "EDBLASTTIME". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
EDBSTATTIME Total Number of Measurements BSC6900 SET GCELLHOEDBPARA(Optional) According to the P/N rule, if the conditions for the handover between the subcells of an enhanced dual-frequency network are met during P of N measurements, the handover is triggered.This parameter specifies the number N. GBFD-114402Enhanced Dual-Band Network Interval Type 1~255 1~255 s None 5 Cell This parameter is valid only when "IUOTP" in "ADD GCELL" is set to EDB_cell. The following condition must be met: "EDBSTATTIME" >= "EDBLASTTIME". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
EDBSYSFLOWLEV Subcell HO Allowed Flow Control Level BSC6900 SET GCELLHOEDBPARA(Optional) If the current system flow control level is greater than this parameter, the handover between the underlaid and overlaid subcells due to low or high load in the underlaid subcell is not allowed. GBFD-114402Enhanced Dual-Band Network Interval Type 0~11 0~11 None None 10 Cell This parameter is valid only when "IUOTP" in "ADD GCELL" is set to EDB_cell. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
EDGE EDGE BSC6900 SET GCELLGPRS(Optional) Whether the current cell supports EDGE. GBFD-114201EGPRS Enumeration Type NO(No), YES(Yes)NO, YES None None None Cell This parameter is valid only when "GPRS" is set to SupportAsInnPcu or SupportAsExtPcu. Read & Write Y Cell Less than 5 minutes None
EDGEADJLASTTIME Handover algorithm II Edge HO AdjCell Valid Time BSC6900 SET GCELLHOBASIC(Optional) According to the P/N rule, if a neighbor cell meets the conditions for selecting the neighbor cell for edge handover in P of N measurement reports, the edge handover to the neighbor cell is triggered.This parameter specifies the number P. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 1~16 1~16, step:0.5 s None 1 Cell This parameter is valid only when "HOCTRLSWITCH" is set to HOALGORITHM2 and "FRINGEHOEN" is set to YES. The following condition must be met: "EDGEADJSTATTIME" >= "EDGEADJLASTTIME". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
EDGEADJLASTTIME1 Handover algorithm I Edge HO AdjCell Valid Time BSC6900 SET GCELLHOBASIC(Optional) According to the P/N rule, if a neighbor cell meets the conditions for selecting the neighbor cell for edge handover for P seconds within N seconds, the edge handover to the neighbor cell is triggered.This parameter specifies the number P. GBFD-510501HUAWEI II Handover Interval Type 1~16 1~16 s None 2 Cell This parameter is valid only when "HOCTRLSWITCH" is set to HOALGORITHM1 and "FRINGEHOEN" is set to YES. The following condition must be met: "EDGEADJSTATTIME1" >= "EDGEADJLASTTIME1". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
EDGEADJSTATTIME Handover algorithm II Edge HO AdjCell Watch Time BSC6900 SET GCELLHOBASIC(Optional) According to the P/N rule, if a neighbor cell meets the conditions for selecting the neighbor cell for edge handover in P of N measurement reports, the edge handover to the neighbor cell is triggered.This parameter specifies the number N. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 1~16 1~16, step:0.5 s None 1 Cell This parameter is valid only when "HOCTRLSWITCH" is set to HOALGORITHM2 and "FRINGEHOEN" is set to YES. The following condition must be met: "EDGEADJSTATTIME" >= "EDGEADJLASTTIME". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
EDGEADJSTATTIME1 Handover algorithm I Edge HO AdjCell Watch Time BSC6900 SET GCELLHOBASIC(Optional) According to the P/N rule, if a neighbor cell meets the conditions for selecting the neighbor cell for edge handover for P seconds within N seconds, the edge handover to the neighbor cell is triggered.This parameter specifies the number N. GBFD-510501HUAWEI II Handover Interval Type 1~16 1~16 s None 3 Cell This parameter is valid only when "HOCTRLSWITCH" is set to HOALGORITHM1 and "FRINGEHOEN" is set to YES. The following condition must be met: "EDGEADJSTATTIME1" >= "EDGEADJLASTTIME1". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
EDGELAST Handover algorithm II Edge HO Valid Time BSC6900 SET GCELLHOBASIC(Optional) According to the P/N rule, if the conditions for edge handover are met in P of N measurement reports, the handover is triggered.This parameter specifies the number P. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 1~16 1~16, step:0.5 s None 1 Cell This parameter is valid only when "HOCTRLSWITCH" is set to HOALGORITHM2 and "FRINGEHOEN" is set to YES. The following condition must be met: "EDGESTAT" >= "EDGELAST". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
EDGELAST1 Handover algorithm I Edge HO Valid Time BSC6900 SET GCELLHOBASIC(Optional) According to the P/N rule, if the conditions for edge handover are met for P seconds within N seconds, the handover is triggered.This parameter specifies the number P. GBFD-510501HUAWEI II Handover Interval Type 1~16 1~16 s None 2 Cell This parameter is valid only when "HOCTRLSWITCH" is set to HOALGORITHM1 and "FRINGEHOEN" is set to YES. The following condition must be met: "EDGESTAT1" >= "EDGELAST1". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
EDGESTAT Handover algorithm II Edge HO Watch Time BSC6900 SET GCELLHOBASIC(Optional) According to the P/N rule, if the conditions for edge handover are met in P of N measurement reports, the handover is triggered.This parameter specifies the number N. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 1~16 1~16, step:0.5 s None 1 Cell This parameter is valid only when "HOCTRLSWITCH" is set to HOALGORITHM2 and "FRINGEHOEN" is set to YES. The following condition must be met: "EDGESTAT" >= "EDGELAST". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
EDGESTAT1 Handover algorithm I Edge HO Watch Time BSC6900 SET GCELLHOBASIC(Optional) According to the P/N rule, if the conditions for edge handover are met for P seconds within N seconds, the handover is triggered.This parameter specifies the number N. GBFD-510501HUAWEI II Handover Interval Type 1~16 1~16 s None 3 Cell This parameter is valid only when "HOCTRLSWITCH" is set to HOALGORITHM1 and "FRINGEHOEN" is set to YES. The following condition must be met: "EDGESTAT1" >= "EDGELAST1". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
EFACHDL UMTS EFACH channel forward factor BSC6900 ADD TRMFACTOR(Optional) WCDMA EFACH channel downlink factor None None Interval Type 0~100 0~100 per cent 20 20 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node that is configured with the factor table. After the successful modification, the parameter takes effect in the following two cases:1. New access subscriber. 2. Bandwidth modification of the existing subscriber
EFTIMMFLAG Effect Immediately Flag BSC6900 SET BTSLOADCTRL(Mandatory) Effect Immediately Flag GBFD-111202O&M of BTS Enumeration Type NO(Effect Later), YES(Effect Immediately) YES, NO None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
EGPRS11BITCHANREQ Support 11BIT EGPRS Access BSC6900 SET GCELLPSBASE(Optional) Whether to support the 11-bit EGPRS access request. GBFD-11920111-Bit EGPRS Access Enumeration Type NO(NO), YES(YES) NO, YES None None YES Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
EGPRS2A EGPRS2-A BSC6900 SET GCELLGPRS(Optional) Whether the current cell supports EGPRS2-A. GBFD-510803GBFD-510804 Uplink EGPRS2-ADownlink EGPRS2-A Enumeration Type NO(No), YES(Yes)NO, YES None None None Cell This parameter is valid only when "GPRS" is set to SupportAsInnPcu. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
EGPRSBEPLIMIT8PSK EDGE 8PSK Quality Threshold BSC6900 SET GCELLNC2PARA(Optional) Used for EDGE 8PSK transmission quality statistics. If MEAN_BEP is less than or equals to this threshold, the transmission quality is regarded to be deteriorated. MEAN_BEP indicates the average error code rate in one measurement report period. GBFD-116201Network-Controlled Cell Reselection (NC2) Interval Type 0~31 0~31 None None 16 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
EGPRSBEPLIMITGMSK EDGE GMSK Quality Threshold BSC6900 SET GCELLNC2PARA(Optional) Used for EDGE GMSK transmission quality statistics. If MEAN_BEP is less than or equals to this threshold, the transmission quality is regarded deteriorated. MEAN_BEP indicates the average error code rate in one measurement report period. GBFD-116201Network-Controlled Cell Reselection (NC2) Interval Type 0~31 0~31 None None 7 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
EM EndType BSC6900 SET TZ(Mandatory) Type of the end date. "WEEK" indicates that the end date is a weekday. "DATE" indicates that the end date is a month day. "DATEWEEK" indicates the end date is expressed by a combination of weekday and month day. MRFD-210301Configuration Management Enumeration Type DATE(Input with date), WEEK(Input with week), DATEWEEK(Input with date and week) DATE, WEEK, DATEWEEK None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
EMCPRILV Priority of Emergency Call BSC6900 SET GCELLCCAD(Optional) Priority level of an emergency call. If this parameter is set to 15, the functions of reserving TCHs for emergency calls and preempting TCHs are not enabled. If the two functions need to be enabled, set this parameter to a value from 1 to 14. If the value of "Emergency Call Preemption Permitted" is ON, this parameter can also be used for TCH preemption. The value 1 means the highest priority and 14 means the lowest. GBFD-110202Emergency Call Service (TS12) Interval Type 1~15 1~15 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
EMERGENCY Emergency verification BSC6900 ADD MTP3LKS(Optional) Whether to verify the centralized signaling link in the case of the link establishment. ON: emergency verification, that is, the verification is not required. OFF: non emergency verification, that is, the verification is required. None None Enumeration Type OFF(OFF), ON(ON) OFF, ON None OFF OFF MTP3 linkNone Read & Write N (No impact on the UE in idle mode) Not involved Not involved For the modification of the parameter, See the ITU-T Q704.
EMITTHD Error emit threshold BSC6900 ADD MPGRP(Optional) Error emit threshold. GBFD-118611GBFD-118622 Abis IP over E1/T1A IP over E1/T1 Enumeration Type ERR_PFM_5E6(OCCUR:5E-6), ERR_PFM_1E5(OCCUR:1E-5), ERR_PFM_5E5(OCCUR:5E-5), ERR_PFM_1E4(OCCUR:1E-4), ERR_PFM_5E4(OCCUR:5E-4), ERR_PFM_1E3(OCCUR:1E-3), ERR_PFM_5E3(OCCUR:5E-3) ERR_PFM_5E6, ERR_PFM_1E5, ERR_PFM_5E5, ERR_PFM_1E4, ERR_PFM_5E4, ERR_PFM_1E3, ERR_PFM_5E3 None None ERR_PFM_1E5 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
EMLDSCP EML DSCP BSC6900 SET BTSABISPRIMAP(Optional) Differentiated service code of the specified EML None None Interval Type 0~63 0~63 None None None BSC6900None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
EMLPPEN Allow EMLPP BSC6900 SET GCELLCCBASIC(Optional) Whether to allow the function of enhanced multi-level precedence and preemption (eMLPP). With the eMLPP function enabled, the network can use different policies such as queuing, preemption, or directed retry based on the priorities of different calls when network resources are occupied. If this parameter is set to YES, when preemption occurs, the MS with the lowest priority initiates a handover, and the MS with a higher priority seizes the idle channel after a handover. If this parameter is set to NO, an MS with a lower priority releases the channel, the MS with a higher priority seizes the idle channel after the release.The eMLPP has up to seven priorities: A, B, 0, 1, 2, 3, and 4. The two highest priorities A and B are internally reserved for local use only. Priorities 0 to 4 can be subscribed by MSs for global use. With the support of the MSC, HLR, and mobile terminal (containing a SIM card), the eMLPP function can be perfectly implemented. GBFD-115001Enhanced Multi Level Precedence and Preemption(EMLPP) Enumeration Type NO(No), YES(Yes)NO, YES None None NO Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
EMLPPPRIORITY eMLPP Priority BSC6900 SET GCELLGSMR(Optional) Indicating whether the eMLPP function is enabled in a cell and indicating the eMLPP priority of the cell. From high to low, the priorities are A, B, 0, 1, 2, 3, 4. No priority is the lowest. GBFD-510307Group Call EMLPP Enumeration Type NoPriority(No Priority), Priority4(Priority 4), Priority3(Priority3), Priority2(Priority 2), Priority1(Priority 1), Priority0(Priority 0), PriorityB(Priority B), PriorityA(Priority A) NoPriority, Priority4, Priority3, Priority2, Priority1, Priority0, PriorityB, PriorityA None None NoPriority Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
EMLPPPRIORITY Emlpp Priority In Paging BSC6900 SET OTHSOFTPARA(Optional) Whether to include the Emlpp Priority information element in the Paging Command message over the Abis interface when "Allow EMLPP" is set to YES and the Emlpp flag in the Bitmap information element of the Paging message received from the MSC is 1 GBFD-115001Enhanced Multi Level Precedence and Preemption(EMLPP) Enumeration Type NO(No), YES(Yes)NO, YES None None NO BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
EMLPRI EML Priority BSC6900 SET BTSABISPRIMAP(Optional) Service priority of the specified EML None None Interval Type 0~7 0~7 None None None BSC6900None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
EMLSP EML Service PRI BSC6900 SET BSCSRVPRI(Optional) Service priority of the extension maintenance link (EML) GBFD-118605IP QOS Interval Type 0~7 0~7 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
EMLVLANID EML VlanId BSC6900 SET BTSABISPRIMAP(Optional) Specified EML Vlan Id None None Interval Type 2~4094 2~4094 None None None BSC6900None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
EMONTH End month BSC6900 SET TZ(Mandatory) Month on which DST ends MRFD-210301Configuration Management Enumeration Type JAN(January), FEB(February), MAR(March), APR(April), MAY(May), JUN(June), JUL(July), AUG(August), SEP(September), OCT(October), NOV(November), DEC(December) JAN, FEB, MAR, APR, MAY, JUN, JUL, AUG, SEP, OCT, NOV, DEC None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
EMSIP EMS IP Address BSC6900 ADD EMSIP(Mandatory) IP address of the NE management system None None IP Address Type None 0.0.0.0~255.255.255.255 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ENABLE Fallback Function Enable BSC6900 SET BTSFALLBACK(Optional) Whether to enable the fallback function for the BTS GBFD-510309Group Call Reliability Enhancing Enumeration Type NO(No), YES(Yes)NO, YES None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter is supported only by the following types of BTSs: BTS3012, BTS3006C, BTS3012AE, BTS3012 II, and BTS3002E.
ENABLED TMA Power Supply Enabled BSC6900 SET BTSTMA(Mandatory) Whether to enable the power supply of the TMA GBFD-111202O&M of BTS Enumeration Type ENABLED(Enabled), DISABLED(Disabled) ENABLED, DISABLEDNone None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ENCRY Encryption Algorithm BSC6900 SET GCELLBASICPARA(Optional) Encryption algorithm supported by the BSS side GBFD-113501GBFD-113503 A5/1 and A5/2 Ciphering AlgorithmA5/1 Encryption Flow Optimization Bit Field Type A5/0~0 A5/1~1 A5/2~2 A5/3~3 A5/4~4 A5/5~5 A5/6~6 A5/7 A5/0, A5/1, A5/2, A5/3, A5/4, A5/5, A5/6, A5/7 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The value of this parameter must be the same at both the BSS side and the NSS side. Whether the BSC is encrypted and the chosen encryption algorithm type must be described in the MAP function process of the MSC. When setting the encryption algorithm type of the BSC, you must refer to the data configuration function of the BSC and the functions of the MS.
ENCRYMODE Transport Encrypted Mode BSC6900 SET FTPSSRV(Optional) Encryption mode used when the NE serves as the FTP clientAUTO: indicating that the FTP client automatically selects the encryption modePLAINTEXT: indicating that the plain text mode is used forcibly.ENCRYPTED: indicating that the encrypted mode is used forcibly. GBFD-111203O&M of BSC Enumeration Type AUTO(Automatic), PLAINTEXT(Plaintext), ENCRYPTED(SSL Encrypted) AUTO, PLAINTEXT, ENCRYPTED None AUTO AUTO RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ENCRYMODE The Encrypted Mode BSC6900 SET FTPSCLT(Optional) Encryption mode supported when the NE serves as the FTP serverAUTO: indicating that the FTP client automatically selects the encryption modePLAINTEXT: indicating that the plain text mode is used forcibly.ENCRYPTED: indicating that the encrypted mode is used forcibly. GBFD-111203O&M of BSC Enumeration Type AUTO(Auto), PLAINTEXT(Plaintext), ENCRYPTED(SSL Encrypte) AUTO, PLAINTEXT, ENCRYPTED None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
End2EndTraceState Support end-to-end user tracing function BSC6900 SET OTHSOFTPARA(Optional) Whether to enable end-to-end user tracing for the BSC. If this parameter is set to YES, the BSC starts end-to-end user tracing after the BSC receives the MSC Invoke Trace or BSS Invoke Trace message from the MSC. GBFD-116401End-to-End MS Signaling Tracing Enumeration Type NO(No), YES(Yes)NO, YES None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
endaid End Alarm ID BSC6900 EXP ALMLOG(Optional)STAALMLOG(Optional) End number of the alarm record MRFD-210304Faulty Management Interval Type 1~65535 1~65535 None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ENDCIC End CIC BSC6900 BLK ACIC(Mandatory) It indicates the end CIC of the A interface CIC segment. When operation mode is set to OPC index, DPC group index, BSC ID, or CIC, the parameter is mandatory. GBFD-111803A Interface Circuit Management Interval Type 0~65535 0~65535 None None None E1/T1 linkWhen the value of "OPMODE" of "BLK ACIC" is BYCICRANGE, the value of ENDCIC needs to be set. Read & Write N (No impact on the UE in idle mode) Not involved Not involved 1. The block of A interface must be configured. 2. If A over IP is configured, the configuration does not support the operation. 3. The difference between the end CIC and the start CIC is smaller than 256.
ENDCIC End CIC BSC6900 BLK PBCIC(Mandatory) It indicates the end CIC of the Pb interface CIC segment.2. If the search object mode is set to search by the specified range, the parameter is mandatory. GBFD-111203O&M of BSC Interval Type 0~65535 0~65535 None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
EndDayDSTPA Prohibit Close TRX Power End Day BSC6900 ADD BSCDSTPADATE(Mandatory) End date of the date range during which to disable the BSC from shutting down the power amplifier of a TRX dynamically GBFD-111602TRX Power Amplifier Intelligent Shutdown Interval Type 1~31 1~31 None None None BSC6900The following condition must be met: the value of "EndDayDSTPA" is greater than that of "StartDayDSTPA" when "EndMonthDSTPA" and "StartMonthDSTPA" are set to a same value. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ENDHEATTEMP Heater shutdown Temperature BSC6900 SET BTSDHEUBP(Optional) If the ambient temperature reaches the value of this parameter, the heater is shut down.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. GBFD-111202O&M of BTS Interval Type -990~400 -99~40 (step: 0.1) degree Celsius None 0 BTS The value of this parameter must be greater than "Heater Startup Temperature". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
EndMonthDSTPA Prohibit Close TRX Power End Month BSC6900 ADD BSCDSTPADATE(Mandatory) End month of the date range during which to disable the BSC from shutting down the power amplifier of a TRX dynamically GBFD-111602TRX Power Amplifier Intelligent Shutdown Enumeration Type JAN(Jan.), FEB(Feb.), MAR(Mar.), APR(Apr.), MAY(May), JUN(Jun.), JUL(Jul.), AUG(Aug.), SEP(Sep), OCT(Oct.), NOV(Nov.), DEC(Dec) JAN, FEB, MAR, APR, MAY, JUN, JUL, AUG, SEP, OCT, NOV, DEC None None None BSC6900The following condition must be met: "EndMonthDSTPA" >= "StartMonthDSTPA". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ENDSUBTS End Sub Timeslot NO. BSC6900 SET BTSFORBIDTS(Optional) Number of the end sub-timeslot GBFD-111202O&M of BTS Enumeration Type 0(0), 2(2), 4(4), 6(6) 0, 2, 4, 6 None None None BTS None Read & Write Y BTS Less than 5 minutes None
EndTimeTACloseTrxPA Time When the Function Is Disabled BSC6900 SET BSCDSTPA(Optional) Time when the BSC stops shutting down the power amplifier of a TRX dynamically every day GBFD-111602TRX Power Amplifier Intelligent Shutdown Compound Type hour, min, sec 00:00~23:59 None None None BSC6900When "BSCDynSwitchTrxPAAllow" is set to YES, the value of "EndTimeTACloseTrxPA" must be set. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ENDTS End TS BSC6900 BLK ATERE1T1(Mandatory) It indicates the end CIC of the Ater interface CIC segment. GBFD-111801Ater Interface 4:1 Multiplexing Interval Type 8~255 8~255 None None None E1/T1 linkWhen the value of "OPMODE" of "BLK ATERE1T1" is BYCICRANGE, the value of ENDTS needs to be set. Read & Write N (No impact on the UE in idle mode) Not involved Not involved 1. The block of Ater interface must be configured. 2. If the BSC is configured to the integrated BMTC or A over IP is configured, the configuration does not support the operation. 3. If the block operation is applicable to only the ATERTS of the BM subrack. You are not allowed to perform the block operation from the primary BM subrack to the secondary BM subrack.
ENDTS End TS BSC6900 BLK AE1T1(Mandatory) It indicates the end CIC of the A interface CIC segment. When Operation mode is set to subrack No., slot No., port No., or CIC, the parameter is mandatory. GBFD-111803A Interface Circuit Management Interval Type 1~31 1~31, step:8 None None None E1/T1 linkWhen the value of "OPMODE" of "BLK AE1T1" is BYCICRANGE, the value of ENDTS needs to be set. Read & Write N (No impact on the UE in idle mode) Not involved Not involved 1. The block of A interface must be configured. 2. If the BSC is configured to the integrated BMTC or A over IP is configured, the configuration does not support the operation. 3. If the block operation is applicable to only the AE1T1 of the BM subrack. You are not allowed to perform the block operation from the primary BM subrack to the secondary BM subrack.
ENDTS End Timeslot NO. BSC6900 SET BTSFORBIDTS(Mandatory) Number of the end timeslot GBFD-111202O&M of BTS Interval Type 1~31 1~31 None None None BTS None Read & Write Y BTS Less than 5 minutes None
ENF Status BSC6900 SET SCHTSKSW(Mandatory) Status of the scheduled task. This parameter determines whether to start the scheduled task. GBFD-111203O&M of BSC Enumeration Type DISABLED(prohibit_to_use), ENABLED(available) DISABLED, ENABLEDNone None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ENF Subtask Status BSC6900 ADD SUBTSK(Optional) Status of the scheduled subtask to be added GBFD-111203O&M of BSC Enumeration Type DISABLED(prohibit_to_use), ENABLED(available) DISABLED, ENABLEDNone available None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ENGOVERLDTHRSH En Iuo Out Cell General OverLoad Thred BSC6900 SET GCELLHOIUO(Optional) If the load of the underlaid subcell is greater than this threshold, certain calls in the underlaid subcell are handed over to the overlaid subcell to balance the traffic between the overlaid and underlaid subcells. GBFD-113201Concentric Cell Interval Type 0~100 0~100 per cent None 70 Cell This parameter is valid only when "UTOOTRAFHOALLOW" is set to YES. The following condition must be met: "ENSOVERLDTHRSH" > "ENGOVERLDTHRSH" > "ENLOWLDTHRSH". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ENGSMPSDLMACFLOWCTRL User Plane DL Flow Ctrl Switch BSC6900 SET GCELLPSOTHERPARA(Optional) Whether to support PS downlink MAC back pressures in GSM. When the buffer is overflowed, the L2 transmission rate is limited if "User Plane DL Flow Ctrl Switch" is "ON". Thus, the data blocks are not lost. If "User Plane DL Flow Ctrl Switch" is "OFF", the L2 transmission rate is not limited. In this case, the loss of data blocks may occur. When "User Plane DL Flow Ctrl Switch" is set to "ON", the LDR needs to be disabled through the SET LDR command. GBFD-118605IP QOS Enumeration Type OFF(OFF), ON(ON) OFF, ON None None OFF Cell None Read & Write Y Cell Less than 10 minutes None
ENIUO Enhanced concentric allowed BSC6900 ADD GCELL(Mandatory) Whether to enable the enhanced concentric cell algorithm in a concentric cell.If a cell supports the enhanced concentric cell function, when an overlaid-to-underlaid handover or an underlaid-to-overlaid handover is decided, the MS compares the receive level value respectively with the values of "OtoU HO Received Level Threshold" and "UtoO HO Received Level Threshold" in "SET GCELLHOIUO" to decide whether to trigger an enhanced concentric cell handover.If the cell does not support the enhanced concentric cell function, the MS compares the actual receive level value with the threshold of receive level to decide whether to trigger a concentric cell handover. In addition, when an underlaid-to-overlaid handover is decided, the underlay cell load is considered. GBFD-113201Concentric Cell Enumeration Type OFF(Off), ON(On) OFF, ON None None ON Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ENLDHOPRD Load classification HO Period BSC6900 SET GCELLHOIUO(Optional) If all the calls in the overlaid subcell are handed over to the underlaid subcell when the channel seizure ratio of the underlaid subcell is less than "En Iuo Out Cell Low Load Thred", the BSC load increases sharply. In this case, the target subcell may be congested and drop calls. To avoid such a problem, the hierarchical load-based handover algorithm is used to hand over the calls from the overlaid subcell to the underlaid cell level by level.This parameter specifies the period of the handover at each hierarchy level. GBFD-113201Concentric Cell Interval Type 1~255 1~255 s None 5 Cell This parameter is valid only when "IUOTP" in "ADD GCELL" is set to ENIUO. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ENLDHOSTP Load classification HO Step BSC6900 SET GCELLHOIUO(Optional) Signal level step for the hierarchical load-based handover from the overlaid subcell to the underlaid subcell GBFD-113201Concentric Cell Interval Type 0~63 0~63 dB None 5 Cell This parameter is valid only when "IUOTP" in "ADD GCELL" is set to ENIUO. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ENLOWLDTHRSH En Iuo Out Cell Low Load Thred BSC6900 SET GCELLHOIUO(Optional) If the load of the underlaid subcell is less than this threshold, certain calls in the overlaid subcell are handed over to the underlaid subcell to balance the traffic between the overlaid and underlaid subcells. GBFD-113201Concentric Cell Interval Type 0~100 0~100 per cent None 20 Cell This parameter is valid only when "UTOOTRAFHOALLOW" is set to YES. The following condition must be met: "ENSOVERLDTHRSH" > "ENGOVERLDTHRSH" > "ENLOWLDTHRSH". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ENPREEMPTTRANSADMT Transmission Resource Preempting Support BSC6900 SET BSCBASIC(Optional) Whether to support preempting transmission resources GBFD-118605IP QOS Enumeration Type OFF(Off), ON(On) OFF, ON None None ON BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ENQUETRANSADMT Transmission Resource Queuing Support BSC6900 SET BSCBASIC(Optional) Whether to support transmission resources queuing GBFD-118605IP QOS Enumeration Type OFF(Off), ON(On) OFF, ON None None ON BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ENSOVERLDTHRSH En Iuo Out Cell Serious OverLoad Thred BSC6900 SET GCELLHOIUO(Optional) If the load of the underlaid subcell is greater than this threshold, the period of the load-based handover from the underlaid subcell to the overlaid subcell, "UL Subcell Load Hierarchical HO Periods", is decreased by "MOD Step LEN of UL Load HO Period" every second to accelerate the handover. GBFD-113201Concentric Cell Interval Type 0~100 0~100 per cent None 80 Cell This parameter is valid only when "UTOOTRAFHOALLOW" is set to YES. The following condition must be met: "ENSOVERLDTHRSH" > "ENGOVERLDTHRSH" > "ENLOWLDTHRSH". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ENTCHADJALLOW Enhanced TCH Adjust Allowed BSC6900 SET GCELLCHMGBASIC(Optional) Whether to enable the cell to centralize two busy half rate TCHs in different timeslots into one timeslot through handover and then to combine the two idle half rate TCHs in the other timeslot into one full rate TCH dynamically GBFD-113402Dynamic Adjustment Between FR and HR Enumeration Type NO(No), YES(Yes)NO, YES None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ENTITYT Local entity type BSC6900 ADD M3LE(Mandatory) M3UA local entity type. For the description of the ASP and IPSP, see RFC4666. None None Enumeration Type M3UA_ASP, M3UA_IPSP M3UA_ASP, M3UA_IPSP None None None BSC6900None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
ENTITYT Destination entity type BSC6900 ADD M3DE(Mandatory) Destination entity type. None None Enumeration Type M3UA_SGP(M3UA SGP), M3UA_IPSP(M3UA IPSP), M3UA_SS7SP(M3UA SS7SP), M3UA_SP(M3UA SP) M3UA_SGP, M3UA_IPSP, M3UA_SS7SP, M3UA_SP None None None BSC6900Negotiation with the peer network element is required. Read & Write Not involved Not involved Not involved The parameter cannot be modified.
ENUTOOLOADINILEV IniLev for EnUtoO load HO BSC6900 SET GCELLHOIUO(Optional) Initial signal level used to compute the handover zone for an MS during the hierarchical load-based handover from the underlaid subcell to the overlaid subcell of the enhanced concentric cell GBFD-113201Concentric Cell Interval Type 0~63 0~63 dB None 63 Cell This parameter is valid only when "IUOTP" in "ADD GCELL" is set to Concentric_cell and "HOCTRLSWITCH" in "SET GCELLHOBASIC" is set to HOALGORITHM2. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ERCODE Return Code BSC6900 EXP LOG(Optional) Return code of the command. If this parameter is specified, only the corresponding record is displayed. If this parameter is not specified, the return code is not considered. GBFD-111203MRFD-210305 O&M of BSCSecurity Management Interval Type 1~4294967295 1~4294967295 None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ERGCALLDIS Emergent Call Disable BSC6900 SET GCELLCCBASIC(Optional) Whether to disable emergency calls. For the MSs of access levels 0 to 9, if the value of this parameter is NO, emergency calls are enabled. For the MSs of access levels 11 to 15, emergency calls are disabled only when the relevant access control bit is set to 0 and this parameter is set to YES. GBFD-110202Emergency Call Service (TS12) Enumeration Type NO(No), YES(Yes)NO, YES None None NO Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ERRALARMTHD Error-frame alarm threshold BSC6900 SET ETHPORT(Optional)ADD PPPLNK(Optional)ADD MPGRP(Optional) Error-frame alarm threshold None None Enumeration Type O1E3_R5E4(OCCUR:1E-3, RECOVERY:5E-4), O5E4_R1E4(OCCUR:5E-4, RECOVERY:1E-4), O1E4_R5E5(OCCUR:1E-4, RECOVERY:5E-5), O5E5_R1E5(OCCUR:5E-5, RECOVERY:1E-5), O1E5_R5E6(OCCUR:1E-5, RECOVERY:5E-6), O5E6_R1E6(OCCUR:5E-6, RECOVERY:1E-6) O1E3_R5E4, O5E4_R1E4, O1E4_R5E5, O5E5_R1E5, O1E5_R5E6, O5E6_R1E6 None O5E4_R1E4 O5E4_R1E4 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ERRDETECTSW Error-frame detect switch BSC6900 SET ETHPORT(Optional)ADD PPPLNK(Optional)ADD MPGRP(Optional) Error-frame detect switch None None Enumeration Type OFF(OFF), ON(ON) OFF, ON None OFF OFF Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ESLDSCP ESL DSCP BSC6900 SET BTSABISPRIMAP(Optional) Differentiated service code of the specified ESL None None Interval Type 0~63 0~63 None None None BSC6900None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
ESLPRI ESL Priority BSC6900 SET BTSABISPRIMAP(Optional) Service priority of the ESL None None Interval Type 0~7 0~7 None None None BSC6900None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
ESLSP ESL Service PRI BSC6900 SET BSCSRVPRI(Optional) Priority of a service running over an extended signaling link (ESL). ESLs are used for more reliably transmitting important signaling messages. GBFD-118605IP QOS Interval Type 0~7 0~7 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ESLVLANID ESL VlanId BSC6900 SET BTSABISPRIMAP(Optional) Specified ESL Vlan Id None None Interval Type 2~4094 2~4094 None None None BSC6900None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
essn End Sync Serial No. BSC6900 EXP ALMLOG(Optional) End synchronization number of the alarm record MRFD-210304Faulty Management Interval Type 1~2147483646 1~2147483646 None 2147483646 2147483646 RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ESTABINDTIMER T3101 BSC6900 SET GCELLTMR(Optional) Timer for the BSC waiting for an Establish Indication message after sending an Immediate Assignment message. If T3101 expires before the BSC receives an Establish Indication message, the BSS releases the seized SDCCH. GBFD-110502Assignment and Immediate Assignment Interval Type 500~60000 500~60000 ms None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ESTINDL3MSGTAFLAG Add TA to A Interface EST IND BSC6900 SET AITFOTHPARA(Optional) Whether to add the TA value to a complete layer-3 message to provide the LCS function on the A interface GBFD-115403Simple Mode LCS(Cell ID + TA) Enumeration Type CLOSE(Close), OPEN(Open) CLOSE, OPEN None None CLOSE MSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ESTTIME Ring II Rotating Penalty Time BSC6900 SET BTSRINGATTR(Optional) When the OML is switched to a port where the connection is successfully established, the switchover cannot be performed over a certain period of time, which is specified as ring II rotating penalty time. In this manner, frequent switchover between the ports due to intermittent blinking can be avoided. GBFD-117802Fast Ring Network Switch Interval Type 0~255 0~255 s None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ET EndTime BSC6900 SET TZ(Mandatory) End time of DST MRFD-210301Configuration Management Compound Type HOUR, MIN, SEC HOUR, MIN, SEC None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ET End Time BSC6900 EXP LOG(Optional) The operation time of the log record is prior to this time. If this parameter is not specified, the end time is the current time. GBFD-111203MRFD-210305 O&M of BSCSecurity Management Compound Type year, month, date, hour, min, sec 2000-1-1 00:00:00~2037-12-31 23:59:59 None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ET End Time BSC6900 ADD SUBTSK(Mandatory) Time when the scheduled subtask is stopped. If the time mode is set to "DAILY_T", "WEEKLY_T", or "MONTHLY_T", you should set this parameter. GBFD-111203O&M of BSC Compound Type hour, min 00:00~23:59 None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ET Execute Type BSC6900 RUN BATCHFILE(Optional) Execution mode of the commands1. ONE_BY_ONE: indicating that the commands are executed one bye one according to the execution sequence. Only one command can be executed once.2. PARALLEL: indicating that multiple commands are executed in parallel. Multiple commands can be executed once. GBFD-111203O&M of BSC Enumeration Type ONE_BY_ONE(Execute one bye one), PARALLEL(Parallel Execute) ONE_BY_ONE, PARALLEL None None ONE_BY_ONE RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ET End Time BSC6900 COL LOG(Optional) The operation time of the log record is prior to this time. If this parameter is not specified, the end time is the current time. GBFD-111203MRFD-210305 O&M of BSCSecurity Management Compound Type year, month, date, hour, min, sec 2000-1-1 00:00:00~2037-12-31 23:59:59 None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
et End Time BSC6900 EXP ALMLOG(Optional) End time of the alarm record. By default, the end time is 23:59:59. MRFD-210304Faulty Management Compound Type hour, min, sec 00:00:00~23:59:59 None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
et End Time BSC6900 STA ALMLOG(Optional) End time of the alarm record. By default, the end time is 23:59:59. MRFD-210304Faulty Management Compound Type hour, min, sec 00:00:00~23:59:59 None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ET End time BSC6900 ADD GSMSCB(Mandatory) End date and time of a broadcast message. This is a key parameter for identifying a simple cell broadcast message. You can use "DSP GSMSCB" to query and obtain the value of this parameter. GBFD-113602Simplified Cell Broadcast Compound Type year, month, day, hour, min, sec 1970-1-1 00:00:00~2538-12-31 23:59:59 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ETD End Date BSC6900 ADD OP(Mandatory) End date of the user operation. Input format: YYYY&MM&DD GBFD-111203MRFD-210305 O&M of BSCSecurity Management Compound Type year, month, day 2000-1-1~2037-12-31None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ETIME End Time BSC6900 STR BTSLOG(Optional) End time GBFD-111202O&M of BTS Compound Type hour, min, sec 00:00:00~23:59:59 None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ETP Log Type BSC6900 EXP LOG(Optional) Type of the log to be queried. The result is displayed by the specified type. GBFD-111203MRFD-210305 O&M of BSCSecurity Management Enumeration Type LOGINEVENT(LoginEvent), MANAGEEVENT(ManageEvent), AUTHEVENT(AuthEvent), OTHEREVENT(OtherEvent) LOGINEVENT, MANAGEEVENT, AUTHEVENT, OTHEREVENT None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ETT End Time BSC6900 ADD OP(Mandatory) End time of the user operation. The input format of this parameter is HH&MM&SS. GBFD-111203MRFD-210305 O&M of BSCSecurity Management Compound Type hour, min, sec 00:00:00~23:59:59 None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
EWEEK End week BSC6900 SET TZ(Mandatory) Weekday on which DST ends MRFD-210301Configuration Management Enumeration Type SUN(Sunday), MON(Monday), TUE(Tuesday), WED(Wednesday), THU(Thursday), FRI(Friday), SAT(Saturday) SUN, MON, TUE, WED, THU, FRI, SAT None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
EWSEQ End week sequence BSC6900 SET TZ(Mandatory) Sequence of the end week of DST MRFD-210301Configuration Management Enumeration Type FIRST(First), SECOND(Second), THIRD(Third), FOURTH(Fourth), LAST(Last) FIRST, SECOND, THIRD, FOURTH, LAST None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
EX_ANO1_SIG_MAX Upper Limit of Signal Output of External Analog 1 BSC6900 ADD EMU(Optional) Upper limit of extended output analog signal 1. If "Sensor Type of External Analog 1" is set to VOLTAGE, the unit of this parameter is V; if "Sensor Type of External Analog 1" is set to CURRENT, the unit of this parameter is A. MRFD-210301Configuration Management String Type None 1~9 characters V or A 0.02 None None If "Sensor Type of External Analog 1" is set to VOLTAGE, the unit of "Upper Limit of Signal Output of External Analog 1" is V; if "Sensor Type of External Analog 1" is set to CURRENT, the unit of "Upper Limit of Signal Output of External Analog 1" is A. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
EX_ANO1_SIG_MIN Lower Limit of Signal Output of External Analog 1 BSC6900 ADD EMU(Optional) Lower limit of extended output analog signal 1. If "Sensor Type of External Analog 1" is set to VOLTAGE, the unit of this parameter is V; if "Sensor Type of External Analog 1" is set to CURRENT, the unit of this parameter is A. MRFD-210301Configuration Management String Type None 1~9 characters V or A 0.004 None None If "Sensor Type of External Analog 1" is set to VOLTAGE, the unit of "Lower Limit of Signal Output of External Analog 1" is V; if "Sensor Type of External Analog 1" is set to CURRENT, the unit of "Lower Limit of Signal Output of External Analog 1" is A. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
EX_ANO1_TYPE Sensor Type of External Analog 1 BSC6900 ADD EMU(Optional) Sensor type of extended analog signal 1 MRFD-210301Configuration Management Enumeration Type VOLTAGE(Voltage), CURRENT(Current) VOLTAGE, CURRENTNone CURRENT None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
EX_ANO1_VAL_MAX Upper Limit of Measurement Range of External Analog 1 BSC6900 ADD EMU(Optional) Maximum measurement range of extended analog signal 1. If "Sensor Type of External Analog 1" is set to VOLTAGE, the unit of this parameter is V; if "Sensor Type of External Analog 1" is set to CURRENT, the unit of this parameter is A. MRFD-210301Configuration Management String Type None 1~9 characters V or A 100 None None If "Sensor Type of External Analog 1" is set to VOLTAGE, the unit of "Upper Limit of Measurement Range of External Analog 1" is V; if "Sensor Type of External Analog 1" is set to CURRENT, the unit of "Upper Limit of Measurement Range of External Analog 1" is A. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
EX_ANO1_VAL_MIN Lower Limit of Measurement Range of External Analog 1 BSC6900 ADD EMU(Optional) Minimum measurement range of extended analog signal 1. If "Sensor Type of External Analog 1" is set to VOLTAGE, the unit of this parameter is V; if "Sensor Type of External Analog 1" is set to CURRENT, the unit of this parameter is A. MRFD-210301Configuration Management String Type None 1~9 characters V or A 0 None None If "Sensor Type of External Analog 1" is set to VOLTAGE, the unit of "Lower Limit of Measurement Range of External Analog 1" is V; if "Sensor Type of External Analog 1" is set to CURRENT, the unit of "Lower Limit of Measurement Range of External Analog 1" is A. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
EX_ANO2_SIG_MAX Upper Limit of Signal Output of External Analog 2 BSC6900 ADD EMU(Optional) Upper limit of extended output analog signal 2. If "Sensor Type of External Analog 2" is set to VOLTAGE, the unit of this parameter is V; if "Sensor Type of External Analog 2" is set to CURRENT, the unit of this parameter is A. MRFD-210301Configuration Management String Type None 1~9 characters V or A 0.02 None None If "Sensor Type of External Analog 2" is set to VOLTAGE, the unit of "Upper Limit of Signal Output of External Analog 2" is V; if "Sensor Type of External Analog 2" is set to CURRENT, the unit of "Upper Limit of Signal Output of External Analog 2" is A. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
EX_ANO2_SIG_MIN Lower Limit of Signal Output of External Analog 2 BSC6900 ADD EMU(Optional) Lower limit of extended output analog signal 2. If "Sensor Type of External Analog 2" is set to VOLTAGE, the unit of this parameter is V; if "Sensor Type of External Analog 2" is set to CURRENT, the unit of this parameter is A. MRFD-210301Configuration Management String Type None 1~9 characters V or A 0.004 None None If "Sensor Type of External Analog 2" is set to VOLTAGE, the unit of "Lower Limit of Signal Output of External Analog 2" is V; if "Sensor Type of External Analog 2" is set to CURRENT, the unit of "Lower Limit of Signal Output of External Analog 2" is A. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
EX_ANO2_TYPE Sensor Type of External Analog 2 BSC6900 ADD EMU(Optional) Sensor type of extended analog signal 2 MRFD-210301Configuration Management Enumeration Type VOLTAGE(Voltage), CURRENT(Current) VOLTAGE, CURRENTNone CURRENT None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
EX_ANO2_VAL_MAX Upper Limit of Measurement Range of External Analog 2 BSC6900 ADD EMU(Optional) Maximum measurement range of extended analog signal 2. If "Sensor Type of External Analog 2" is set to VOLTAGE, the unit of this parameter is V; if "Sensor Type of External Analog 2" is set to CURRENT, the unit of this parameter is A. MRFD-210301Configuration Management String Type None 1~9 characters V or A 100 None None If "Sensor Type of External Analog 2" is set to VOLTAGE, the unit of "Upper Limit of Measurement Range of External Analog 2" is V; if "Sensor Type of External Analog 2" is set to CURRENT, the unit of "Upper Limit of Measurement Range of External Analog 2" is A. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
EX_ANO2_VAL_MIN Lower Limit of Measurement Range of External Analog 2 BSC6900 ADD EMU(Optional) Minimum measurement range of extended analog signal 2. If "Sensor Type of External Analog 2" is set to VOLTAGE, the unit of this parameter is V; if "Sensor Type of External Analog 2" is set to CURRENT, the unit of this parameter is A. MRFD-210301Configuration Management String Type None 1~9 characters V or A 0 None None If "Sensor Type of External Analog 2" is set to VOLTAGE, the unit of "Lower Limit of Measurement Range of External Analog 2" is V; if "Sensor Type of External Analog 2" is set to CURRENT, the unit of "Lower Limit of Measurement Range of External Analog 2" is A. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
EX_ANO3_SIG_MAX Upper Limit of Signal Output of External Analog 3 BSC6900 ADD EMU(Optional) Upper limit of extended output analog signal 3. If "Sensor Type of External Analog 3" is set to VOLTAGE, the unit of this parameter is V; if "Sensor Type of External Analog 3" is set to CURRENT, the unit of this parameter is A. MRFD-210301Configuration Management String Type None 1~9 characters V or A 0.02 None None If "Sensor Type of External Analog 3" is set to VOLTAGE, the unit of "Upper Limit of Signal Output of External Analog 3" is V; if "Sensor Type of External Analog 3" is set to CURRENT, the unit of "Upper Limit of Signal Output of External Analog 3" is A. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
EX_ANO3_SIG_MIN Lower Limit of Signal Output of External Analog 3 BSC6900 ADD EMU(Optional) Lower limit of extended output analog signal 3. If "Sensor Type of External Analog 3" is set to VOLTAGE, the unit of this parameter is V; if "Sensor Type of External Analog 3" is set to CURRENT, the unit of this parameter is A. MRFD-210301Configuration Management String Type None 1~9 characters V or A 0.004 None None If "Sensor Type of External Analog 3" is set to VOLTAGE, the unit of "Lower Limit of Signal Output of External Analog 3" is V; if "Sensor Type of External Analog 3" is set to CURRENT, the unit of "Lower Limit of Signal Output of External Analog 3" is A. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
EX_ANO3_TYPE Sensor Type of External Analog 3 BSC6900 ADD EMU(Optional) Sensor type of extended analog signal 3 MRFD-210301Configuration Management Enumeration Type VOLTAGE(Voltage), CURRENT(Current) VOLTAGE, CURRENTNone CURRENT None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
EX_ANO3_VAL_MAX Upper Limit of Measurement Range of External Analog 3 BSC6900 ADD EMU(Optional) Maximum measurement range of extended analog signal 3. If "Sensor Type of External Analog 3" is set to VOLTAGE, the unit of this parameter is V; if "Sensor Type of External Analog 3" is set to CURRENT, the unit of this parameter is A. MRFD-210301Configuration Management String Type None 1~9 characters V or A 100 None None If "Sensor Type of External Analog 3" is set to VOLTAGE, the unit of "Upper Limit of Measurement Range of External Analog 3" is V; if "Sensor Type of External Analog 3" is set to CURRENT, the unit of "Upper Limit of Measurement Range of External Analog 3" is A. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
EX_ANO3_VAL_MIN Lower Limit of Measurement Range of External Analog 3 BSC6900 ADD EMU(Optional) Minimum measurement range of extended analog signal 3. If "Sensor Type of External Analog 3" is set to VOLTAGE, the unit of this parameter is V; if "Sensor Type of External Analog 3" is set to CURRENT, the unit of this parameter is A. MRFD-210301Configuration Management String Type None 1~9 characters V or A 0 None None If "Sensor Type of External Analog 3" is set to VOLTAGE, the unit of "Lower Limit of Measurement Range of External Analog 3" is V; if "Sensor Type of External Analog 3" is set to CURRENT, the unit of "Lower Limit of Measurement Range of External Analog 3" is A. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
EX_ANO4_SIG_MAX Upper Limit of Signal Output of External Analog 4 BSC6900 ADD EMU(Optional) Upper limit of extended output analog signal 4. If "Sensor Type of External Analog 4" is set to VOLTAGE, the unit of this parameter is V; if "Sensor Type of External Analog 4" is set to CURRENT, the unit of this parameter is A. MRFD-210301Configuration Management String Type None 1~9 characters V or A 0.02 None None If "Sensor Type of External Analog 4" is set to VOLTAGE, the unit of "Upper Limit of Signal Output of External Analog 4" is V; if "Sensor Type of External Analog 4" is set to CURRENT, the unit of "Upper Limit of Signal Output of External Analog 4" is A. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
EX_ANO4_SIG_MIN Lower Limit of Signal Output of External Analog 4 BSC6900 ADD EMU(Optional) Lower limit of extended output analog signal 4. If "Sensor Type of External Analog 4" is set to VOLTAGE, the unit of this parameter is V; if "Sensor Type of External Analog 4" is set to CURRENT, the unit of this parameter is A. MRFD-210301Configuration Management String Type None 1~9 characters V or A 0.004 None None If "Sensor Type of External Analog 4" is set to VOLTAGE, the unit of "Lower Limit of Signal Output of External Analog 4" is V; if "Sensor Type of External Analog 4" is set to CURRENT, the unit of "Lower Limit of Signal Output of External Analog 4" is A. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
EX_ANO4_TYPE Sensor Type of External Analog 4 BSC6900 ADD EMU(Optional) Sensor type of extended analog signal 4 MRFD-210301Configuration Management Enumeration Type VOLTAGE(Voltage), CURRENT(Current) VOLTAGE, CURRENTNone CURRENT None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
EX_ANO4_VAL_MAX Upper Limit of Measurement Range of External Analog 4 BSC6900 ADD EMU(Optional) Maximum measurement range of extended analog signal 4. If "Sensor Type of External Analog 4" is set to VOLTAGE, the unit of this parameter is V; if "Sensor Type of External Analog 4" is set to CURRENT, the unit of this parameter is A. MRFD-210301Configuration Management String Type None 1~9 characters V or A 100 None None If "Sensor Type of External Analog 4" is set to VOLTAGE, the unit of "Upper Limit of Measurement Range of External Analog 4" is V; if "Sensor Type of External Analog 4" is set to CURRENT, the unit of "Upper Limit of Measurement Range of External Analog 4" is A. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
EX_ANO4_VAL_MIN Lower Limit of Measurement Range of External Analog 4 BSC6900 ADD EMU(Optional) Minimum measurement range of extended analog signal 4. If "Sensor Type of External Analog 4" is set to VOLTAGE, the unit of this parameter is V; if "Sensor Type of External Analog 4" is set to CURRENT, the unit of this parameter is A. MRFD-210301Configuration Management String Type None 1~9 characters V or A 0 None None If "Sensor Type of External Analog 4" is set to VOLTAGE, the unit of "Lower Limit of Measurement Range of External Analog 4" is V; if "Sensor Type of External Analog 4" is set to CURRENT, the unit of "Lower Limit of Measurement Range of External Analog 4" is A. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
EXCACC Exclusive Access BSC6900 SET GCELLSERVPARA(Optional) Whether it is a SoLSA exclusive access cell. If it is a SoLSA exclusive access cell, only the MS subscribing the Localised Service Area (LSA) can access this cell. GBFD-114101GPRS Enumeration Type NoExclusive(NoExclusive), Exclusive(Exclusive) NoExclusive, ExclusiveNone None NoExclusive Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
EXPDLRXLEV Expected DL RX_LEV BSC6900 SET GCELLPWRBASIC(Optional) Received signal strength at an MS expected in power forecast, which helps to compute the initial transmit power of the BTS GBFD-117602Active Power Control Interval Type 0~63 0~63 dB None 30 Cell This parameter is valid only when "PWRBCDALLOWD" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
EXPULRXLEV Expected UL RX_LEV BSC6900 SET GCELLPWRBASIC(Optional) Received signal strength at the BTS expected in power forecast, which helps to compute the initial transmit power of an MS GBFD-117602Active Power Control Interval Type 0~63 0~63 dB None 30 Cell This parameter is valid only when "PWRBCDALLOWD" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
EXT2GCELLID Cell Index BSC6900 ADD GEXT2GCELL(Mandatory) ID of the cell. The cell ID cannot conflict with other cell IDs in the BSC. The cells in the BSC are numbered sequentially. MRFD-210301Configuration Management Interval Type 2048~5047 2048~5047 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
EXT2GCELLNAME Cell Name BSC6900 ADD GEXT2GCELL(Mandatory) Name of the cell GBFD-111202O&M of BTS String Type None 1~64 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
EXT3GCELLID Cell Index BSC6900 ADD GEXT3GCELL(Mandatory) ID of the cell. The cell ID cannot conflict with other cell IDs in the BSC. The cells in the BSC are numbered sequentially. MRFD-210301Configuration Management Interval Type 5048~8047 5048~8047 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
EXT3GCELLNAME Cell Name BSC6900 ADD GEXT3GCELL(Mandatory) Name of the cell GBFD-111202O&M of BTS String Type None 1~64 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
EXTADJCELLID BSC Adjacent Cell Index BSC6900 ADD EXTNCELL(Mandatory) Index of the cell in the adjacent BSC. MRFD-210301Configuration Management Interval Type 2048~5047 2048~5047 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None.
EXTADJCELLNAME BSC Adjacent Cell Name BSC6900 ADD EXTNCELL(Mandatory) Name of the cell in the adjacent BSC. MRFD-210301Configuration Management String Type None 1~64 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None.
EXTCELLTHRENH Extended Cell Throughput Enhancement BSC6900 SET GCELLPSOTHERPARA(Optional) Whether to support the downlink throughput enhancement function of the dual timeslot cell. When this switch is turned on, the system can allocate the packet downlink channel of the odd number timeslot of dual timeslot bearer of the dual timeslot cell. GBFD-114001Extended Cell Enumeration Type CLOSE(Close), OPEN(Open) CLOSE, OPEN None None CLOSE Cell None Read & Write Y Cell Less than 5 minutes None
EXTFlag Extended Switch of Input Alarm BSC6900 SET BTSALM(Optional) Whether to enable alarm extension input for the BTS GBFD-111202O&M of BTS Enumeration Type NO(No), YES(Yes)NO, YES None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
EXTMEASORD Extension Measurement Command BSC6900 SET GCELLEXTMSRPARA(Optional) Whether the network requires an MS to send an extension measurement report GBFD-110801GBFD-110802 Processing of Measurement ReportPre-processing of Measurement Report Enumeration Type EM0(EM0), EM1(EM1) EM0, EM1 None None EM0 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
EXTRPTPERIOD Extension MR Period BSC6900 SET GCELLEXTMSRPARA(Optional) Time interval between two extension measurement reports GBFD-110801GBFD-110802 Processing of Measurement ReportPre-processing of Measurement Report Enumeration Type 60sec(60sec), 120sec(120sec), 240sec(240sec), 480sec(480sec), 960sec(960sec), 1920sec(1920sec), 3840sec(3840sec), 7680sec(7680sec) 60sec, 120sec, 240sec, 480sec, 960sec, 1920sec, 3840sec, 7680sec s None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved If the value of this parameter is too small, extension measurement reports are sent frequently. If the value is too large, feedback information may not be sent promptly in fewer extension measurement reports.
EXTRPTTYPE Extension MR Type BSC6900 SET GCELLEXTMSRPARA(Optional) Type of an extension measurement report.There are three types of extension measurement reports: type 1, type 2, and type 3.Type 1: No matter whether the BSIC was decoded, the MS sends the network a measurement report on the six strongest TRXs. The measurement report contains the received signal level and the decoded BSIC.Type 2: The MS sends the network a measurement report on the six strongest TRXs. For the six carriers, the BSIC must be decoded successfully and the NCC specified by NCC_PERMITTED is carried. The measurement report contains the received signal level and the decoded BSIC.Type 3: The MS does not need to decode the BSIC for the TRXs that the measurement report concerns. The measurement report contains the received signal level and the interference measurement of one of the concerned TRXs. GBFD-110801GBFD-110802 Processing of Measurement ReportPre-processing of Measurement Report Enumeration Type TYPE1(TYPE1), TYPE2(TYPE2), TYPE3(TYPE3) TYPE1, TYPE2, TYPE3 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
EXTTP Cell Extension Type BSC6900 ADD GCELL(Optional) Whether a cell is an extension cell.A double-timeslot extension cell regards an additional TDMA frame as access delay extension. In theory, the supported TA value is 219, that is, a time delay of about 120 kilometers. GBFD-114001Extended Cell Enumeration Type Normal_cell(Normal cell), DualTS_ExtCell(Double Timeslot Extension Cell) Normal_cell, DaulTst_ExtCell None None Normal_cell Cell None Read & Write Y Cell Less than 1 minute None
EXTUTBFNODATA Not Send Dummy Message with Extended Uplink TBF BSC6900 SET GCELLPSBASE(Optional) Whether to send the Dummy message during the deactivated period of the extended uplink TBF. GBFD-119203Extended Uplink TBF Enumeration Type SEND(SEND), NOTSEND(NOTSEND) SEND, NOTSEND None None SEND Cell If "UPEXTTBFINACTDELAY" in the "SET GCELLPRIVATEOPTPARA" command is set to 0, "EXTUTBFNODATA" must be 0. If "UPEXTTBFINACTDELAY" is not set to 0, "EXTUTBFNODATA" can be 0 or 1. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FACCHRESENDINT FACCH Msg Resend Interval BSC6900 SET GCELLGSMR(Optional) Interval of sending a paging message or notification message on the FACCH. Messages on the FACCH are sent in the mode of speech frame stealing. A large number of consecutive stolen speech frames may affect the voice quality and even lead to no voice. Therefore, the BTS must control the time interval of sending a paging or notification message on the FACCH for the purpose of reducing the impact on the voice quality. GBFD-510301GBFD-510302 Public Voice Group Call ServicePublic Voice Broadcast Service Interval Type 0~255 0~255, step: 50 ms None 8 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FACCHSENDNOTMSGIND FACCH Send Notification Msg Indication BSC6900 SET GCELLGSMR(Optional) Whether to allow sending notification messages on the FACCH. If the value of this parameter is YES, an MS engaged in a point-to-point call can receive a notification message for a group call. You can interrupt the existing call and join the group call. GBFD-510307Group Call EMLPP Enumeration Type NO(No), YES(Yes)NO, YES None None NO Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FACCHSENDPGMSGIND FACCH Send Paging Msg Indication BSC6900 SET GCELLGSMR(Optional) Whether to allow sending paging messages on the FACCH. If the value of this parameter is YES, an MS can receive a paging message on the group call channel. You can leave the group call and respond to the paging message. GBFD-510307Group Call EMLPP Enumeration Type NO(No), YES(Yes)NO, YES None None NO Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FACTORSW TRM Factor switch BSC6900 SET BTSABISPRIMAP(Optional) Activation factor switch None None Enumeration Type OFF(OFF), ON(ON) OFF, ON None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FACTORYMODE Factory Mode BSC6900 SET GCELLCHMGBASIC(Optional) If this parameter is set to ON, the BSC assigns the channels in the TRXs of the cell in a polling manner. Therefore, each TRX has an even chance to be used. In this way, the connection between the TRX and the RF can be checked without manual dialing tests. GBFD-111005Enhanced Channel Assignment Algorithm Enumeration Type OFF(Off), ON(On) OFF, ON None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FAILSIGSTRPUNISH Penalty Level after HO Fail BSC6900 SET GCELLHOFITPEN(Optional) Penalty signal level imposed on a target cell to which the handover fails due to congestion or poor radio quality. This penalty helps to prevent the MS from making a second handover attempt to the target cell. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 0~63 0~63 dB None 30 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FANADJUSTCOMMAND0 Continuous adjustment command BSC6900 SET FANSPEED(Optional) Continuous speed adjustment MRFD-210301Configuration Management Enumeration Type PLUS_1, MINUS_1PLUS_1, MINUS_1 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FANADJUSTCOMMAND1 Discrete adjustment command BSC6900 SET FANSPEED(Optional) Discrete speed adjustment MRFD-210301Configuration Management Enumeration Type HIGH_SPEED, LOW_SPEED HIGH_SPEED, LOW_SPEED None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FANADJUSTCOMMAND2 Duty ratio adjustment command BSC6900 SET FANSPEED(Optional) Duty ratio-based speed adjustment MRFD-210301Configuration Management Interval Type 55~100 55~100 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FANADJUSTMODE Fan adjustment mode BSC6900 SET FANSPEED(Optional) Fan adjustment mode MRFD-210301Configuration Management Enumeration Type CONTINUOUS, DISCRETE, DUTY_RATIO CONTINUOUS, DISCRETE, DUTY_RATIO None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FANFLAG Fan Type BSC6900 SET FANSPEED(Mandatory) Type of the fanMRFD-210301Configuration Management Enumeration Type NORMAL_FAN, IND_FAN NORMAL_FAN, IND_FAN None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FANSPEEDMODE Speed adjustment mode BSC6900 SET FANSPEED(Mandatory) Fan adjustment mode MRFD-210301Configuration Management Enumeration Type NO_SPEED_ADJUSTMENT, HW_AUTO_TEMPERATURE_CONTROL, SPECIFY_RATE, SOFTWARE_CONTROL NO_SPEED_ADJUSTMENT, HW_AUTO_TEMPERATURE_CONTROL, SPECIFY_RATE, SOFTWARE_CONTROL None None SOFTWARE_CONTROL BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FANTYPE FanBox Type BSC6900 LOD FAN(Mandatory) Type of the fan box MRFD-210301Configuration Management Enumeration Type IND_FAN(Independent Fan), NORMAL_FAN(Normal Fan) IND_FAN, NORMAL_FAN None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FASTCALLTCHTHRESHOLD Fast Call Setup TCH Usage Threshold BSC6900 SET GCELLBASICPARA(Optional) After a channel request message is received, the type of the channel needs to be specified. In this case, if the threshold of the load on the TCH in the current cell is smaller than Fast Call Setup TCH Usage Threshold and the request message is not issued during location update or paging, a TCH is preferentially assigned. None None Interval Type 0~100 0~100 per cent None 0 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FASTCNETFLAG Configure Ring II BSC6900 SET BTSRINGATTR(Optional) Ring II function switch. The parameter should be set to "YES" when the ring II function is enabled. GBFD-117802Fast Ring Network Switch Enumeration Type NO(No), YES(Yes)NO, YES None None None BTS If this parameter is set to "YES", the following condition must be met: The setting of this parameter must meet the following condition: "FallBack Start Time" > "Ring II Wait Time Before Switch" + "Ring II Try Rotating Duration Time". If this parameter is set to "NO", the following condition must be met: "FallBack Start Time" > "Ring I Wait Time Before Switch" + "Ring I Try Rotating Duration Time". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FaultDetectSwitch Fault Detect Switch BSC6900 SET TCPARA(Optional) Whether to enable the memory self-check and self-healing function GBFD-111203O&M of BSC Enumeration Type OFF(Off), ON(On) OFF, ON None None OFF Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FC Physical layer flow control switch BSC6900 SET ETHPORT(Optional) Whether to send and process the flow control frame on the physical layer. The setting of this parameter must be negotiated with that on the interconnected side. None None Enumeration Type OFF(OFF), ON(ON) OFF, ON None None None Ethernet port None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FC Flow Control BSC6900 SET BTSETHPORT(Optional) If the parameter is set to "YES", it indicates that some data packets are discarded to ensure the basic functions of the BTS are not affected when the FE port is overloaded. After the port is not overloaded, the flow control is stopped. GBFD-118601Abis over IP Enumeration Type CLOSE(Close), OPEN(Open) CLOSE, OPEN None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FCETHD Flow Control End Threshold BSC6900 SET GTRXFC(Optional) Threshold for stopping RSL flow control. If the occupancy of the LAPD queue is less than this threshold, the BSC stops flow control. GBFD-111705GSM Flow Control Interval Type 0~100 0~100 None None None TRX None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FCINDEX Flow control parameter index BSC6900 SET OPT(Mandatory) Flow control parameter index None None Interval Type 0~1999 0~1999 None None None Board None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
FCINDEX Flow control parameter index BSC6900 SET ETHPORT(Mandatory) Flow control parameter index None None Interval Type 0~1999 0~1999 None None None Ethernet port None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
FCINDEX Flow control parameter index BSC6900 ADD PPPLNK(Optional) Flow control parameter index GBFD-118611GBFD-118622 Abis IP over E1/T1A IP over E1/T1 Interval Type 0~1999 0~1999 None 0 0 PPP link None Read & Write Y BSC6900 Interrupt the service until negotiate successfully again. Negotiation can succeed only when the configuration is consistent on the local and peer ends.
FCINDEX Flow control parameter index BSC6900 ADD MPGRP(Optional) Flow control parameter index GBFD-118611GBFD-118622 Abis IP over E1/T1A IP over E1/T1 Interval Type 0~1999 0~1999 None 0 0 MP groupNone Read & Write N (No impact on the UE in idle mode) Not involved Not involved Negotiation can succeed only when the configuration is consistent on the local and peer ends.
FCINDEX Flow control parameter index BSC6900 ADD IPLOGICPORT(Optional) Flow control parameter index None None Interval Type 0~1999 0~1999 None 0 0 IP logical port This index can correspond with any threshold (maximum value of 80) in the six queues. The following condition must be met: threshold x 64 x 1024 x logical port bandwidth < 4294967295(0xFFFFFFFF). Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FCINDEX Flow control parameter index BSC6900 ADD PORTFLOWCTRLPARA(Mandatory) Flow control parameter index None None Interval Type 10~1999 10~1999 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FCINDEX Flow control parameter index BSC6900 ADD ETHTRK(Optional) Flow control parameter index MRFD-210103Link aggregation Interval Type 0~1999 0~1999 None 0 0 Ethernet port None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
FCINDEX Flow control parameter index BSC6900 SET BTSABISPRIMAP(Mandatory) Flow control parameter index None None Interval Type 2~1999 2~1999 None None None BSC6900None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
FCN Cabinet No. of father BTS BSC6900 ADD BTSAUTOPLAN(Mandatory) Cabinet No. of the father BTS GBFD-510701Compact BTS Automatic Configuration and Planning Interval Type 0~62 0~62 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FCN Cabinet No. of father BTS BSC6900 ADD BTSCONNECT(Optional) Cabinet No. for the port of the father BTS GBFD-111202O&M of BTS Interval Type 0~62 0~62 None None None BTS None Read & Write Y BTS Less than 5 minutes This parameter can be modified only when the BTS is deactivated.
FCSTHD Flow Control Start Threshold BSC6900 SET GTRXFC(Optional) Threshold for starting RSL flow control. If the occupancy of the LAPD queue is greater than this threshold, the BSC starts flow control. GBFD-111705GSM Flow Control Interval Type 0~100 0~100 per cent None None TRX None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FCSTYPE CRC check mode BSC6900 ADD PPPLNK(Optional) CRC verification mode GBFD-118611GBFD-118622 Abis IP over E1/T1A IP over E1/T1 Enumeration Type None(None), 16bit(16bit), 32bit(32bit) None, 16bit, 32bit None 16bit 16bit PPP link None Read & Write Y PPP link Interrupt the service until negotiate successfully again. Negotiation fails if this parameter is modified.
FCSTYPE CRC check mode BSC6900 ADD MPLNK(Optional) CRC verification mode GBFD-118611GBFD-118622 Abis IP over E1/T1A IP over E1/T1 Enumeration Type None(None), 16bit(16bit), 32bit(32bit) None, 16bit, 32bit None 16bit 16bit MP link None Read & Write Y BSC6900 Interrupt the service until negotiate successfully again. Negotiation fails if this parameter is modified.
FCSW Flow control switch BSC6900 SET FCSW(Mandatory) Flow control switch. Other switches are valid only when "Flow control switch" is "ON". WRFD-040100Flow Control Enumeration Type ON, OFF ON, OFF None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FCV Float-Charging Voltage BSC6900 SET BTSAPMUBP(Optional) Float charging voltage. Float charging compensates the discharged capacity of the battery so that the battery can be charged to full voltage indefinitely. The value of this parameter is slightly lower than the even charging voltage. See the vendor specification for the setting of this parameter.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. GBFD-111202O&M of BTS Interval Type 432~575 43.2~57.5 (step: 0.1) V None 535 BTS The value of this parameter must be smaller than "Even charging voltage" and at least two volts higher than "DC undervoltage alarm threshold". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FDDBA1TAG FDDBA1 Input Tag BSC6900 SET GCELLIDLEFDDBA1(Mandatory) Input mode of the BA lists.AUTO: In this mode, the system fills in the BA1 and BA2 lists according to neighboring relations of cells.MANU: In this mode, you can maintain the BA tables by yourself. If the neighboring relations of cells are changed, for example, after a neighboring cell is added or deleted, you must maintain the BA1 and BA2 lists by yourself. GBFD-114301GSM/WCDMA Interoperability Enumeration Type AUTO(Auto), MANU(Manu) AUTO, MANU None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FDDBA2TAG FDDBA2 input tag BSC6900 SET GCELLHOFDDBA2(Mandatory) This parameter indicate whether to generate the FDD BA2 table automatically according to neighbor cell relations or to input the FDD BA2 table manually MRFD-210301Configuration Management Enumeration Type AUTO(Auto), MANU(Manu) AUTO, MANU None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FDDCELLOFF FDD Reporting Offset BSC6900 SET GCELLCCUTRANSYS(Optional) Offset of a FDD cell report.When the priority of a 3G cell is sequenced, the value of this parameter be added to the receive level of the 3G cell in the measurement report.The values of this parameter correspond to the following decibel values:0: 0 dB1: 6 dB...7: 42 dB GBFD-114301GSM/WCDMA Interoperability Interval Type 0~7 0~7, step: 6 dB None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FDDCELLTHRED FDD Reporting Threshold BSC6900 SET GCELLCCUTRANSYS(Optional) Threshold of a FDD cell report.When the receive level value in the measurement report about a 3G cell exceeds the value of this parameter, the measurement report takes effect. After the valid measurement report is filtered, the 3G cell joins the cell priority sequence.The values of this parameter correspond to the following decibel values:0: 0 dB1: 6 dB...6: 36 dB7: GBFD-114301GSM/WCDMA Interoperability Interval Type 0~7 0~7, step: 6 dB None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FDDDIVERSITY Diversity Indication BSC6900 SET GCELLIDLEFDDBA1(Mandatory) Diversity indication of a 3G cell. This parameter indicates whether the transmit diversity mode on the common channel in a cell is activated. GBFD-114301GSM/WCDMA Interoperability Interval Type 0~1 0~1 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FDDDLUARFAN Downlink Frequency BSC6900 SET GCELLIDLEFDDBA1(Mandatory) Downlink frequency number that an MS in the connected mode retrieves from the 3G neighboring cell list. The numbers are sent through system message 2QUATER/MI. The value ranges of frequency numbers vary with corresponding band reporting. GBFD-114301GSM/WCDMA Interoperability Interval Type 0~16383 0~16383 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The value ranges of frequency numbers vary with corresponding band reporting.
FDDECQUALTHRSH PS FDD Ec/No Quality Threshold BSC6900 ADD GEXT3GCELL(Optional) Minimum Ec/No of the 3G FDD cell candidate GBFD-114301GSM/WCDMA Interoperability Interval Type 0~49 0~49 dB None 10 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FDDFREQCNUM FDD Multirate Reporting BSC6900 SET GCELLCCUTRANSYS(Optional) Number of UTRAN FDD cells that should be included in measurement report GBFD-114301GSM/WCDMA Interoperability Interval Type 0~3 0~3 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FDDQMIN FDD Qmin BSC6900 SET GCELLCCUTRANSYS(Optional) One of the thresholds of the signal level for 3G cell reselection.A 3G cell can be a candidate for cell reselection only when the receive level of the 3G cell is greater than the value of this parameter.The values 0 to 7 of this parameter corresponds respectively to the following decibel values: -20dB, -6dB, -18dB, -8dB, -16dB, -10dB, -14dB, and -12dB. GBFD-114301GSM/WCDMA Interoperability Interval Type 0~7 0~7 dB None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FDDQMINOFFSET FDD Qmin Offset BSC6900 SET GCELLCCUTRANSYS(Optional) Diversity transmitter 32QAM delay. Only the double-transceiver BTS and the subsequent distributed BTS support the function of transmit diversity delay. Therefore, this parameter applies to only the BTS of these two types. For the BTS of other types, this parameter is set to an invalid value 255. GBFD-114301GSM/WCDMA Interoperability Interval Type 0~7 0~7 dB None 0 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FDDQOFF FDD Q Offset BSC6900 SET GCELLCCUTRANSYS(Optional) A 3G cell can be a candidate cell only when the average receive level of the 3G cell is greater than the value of this parameter of the current serving cell.The values of this parameter correspond to the following decibel values:0: - (always select a cell if acceptable)1: -28 dB2: -24 dB...15: 28 dB GBFD-114301GSM/WCDMA Interoperability Interval Type 0~15 0~15 dB None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FDDREP FDD REP QUANT BSC6900 SET GCELLCCUTRANSYS(Optional) Measurement mode of a measurement report on a FDD cell.Ec/N0: using the signal-to-noise ratioRSCP: using the received signal code power GBFD-114301GSM/WCDMA Interoperability Enumeration Type RSCP(RSCP), EcN0(Ec/N0) RSCP, EcN0 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
5/5/2014
Confidential Information of Huawei.
No Spreading without Permission
Page8of42
226347869.xls.ms_office Security Level:
FDDRSCPMIN FDD RSCP Min. BSC6900 SET GCELLCCUTRANSYS(Optional) Minimum level threshold of UTRAN cell reselection. During the cell reselection decision from a GSM cell to a FDD cell, this parameter is used to calculate the RSCP threshold of the target cell. The values of this parameter correspond to the following decibel values: 0 = -114 dBm, 1 = -112 dBm, 2 = -110 dBm, ...14 = -86 dBm, 15 = -84 dBm. GBFD-114301GSM/WCDMA Interoperability Interval Type 0~15 0~15 dBm None 6 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FDDRSCPQUALTHRSH PS FDD RSCP Quality Threshold BSC6900 ADD GEXT3GCELL(Optional) Minimum RSCP of the 3G FDD cell candidate GBFD-114301GSM/WCDMA Interoperability Interval Type 0~63 0~63 None None 10 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FDDSCRAMBLE Scrambling Code BSC6900 SET GCELLIDLEFDDBA1(Mandatory) Scrambling code of a 3G cell, used for distinguishing MSs or cells. Scrambling codes are used after spreading. Therefore, the bandwidth of a signal is not changed. Instead, signals from different sources are differentiated. Scrambling prevents multiple transmitters from using the same code word for spreading.On the uplink, the scrambling function is used for differentiating MSs. On the downlink, the function is used for differentiating cells. GBFD-114301GSM/WCDMA Interoperability Interval Type 0~511 0~511 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FDWINDOW Fast judgement window BSC6900 SET FCCPUTHD(Optional) Number of CPU usage sampling times for fast judgment. The value of this parameter must be of half size of "Filter window" or smaller. WRFD-040100Flow Control Interval Type 1~1000 1~1000 None None 4 None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FERRPTEN FER Report Enable BSC6900 SET GCELLSOFT(Optional) Whether the BTS reports the frame erase ratio in a measurement report or preprocessed measurement report GBFD-116801Voice Quality Index (Uplink VQI) Enumeration Type NO(No), YES(Yes)NO, YES None None For the double-transceiver BTS and NGBTS, the default value is NO; for other BTS, this parameter is invalid. Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FERSTATTH1 FER Threshold 1 BSC6900 SET GCELLOTHEXT(Optional) If the FER carried in the measurement report (MR) received is lower than or equal to "FER threshold 1", the value of "FER 0 and Quality Level N" is incremented by one. If the FER in the MR received is greater than "FER threshold 1" but meanwhile lower than or equal to "FER threshold 2", the value of "FER 1 and Quality Level N" is incremented by one. GBFD-116801Voice Quality Index (Uplink VQI) Interval Type 0~1000 0~1000 per millNone 2 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FERSTATTH2 FER Threshold 2 BSC6900 SET GCELLOTHEXT(Optional) If the FER carried in the MR received is greater than "FER threshold 2" but meanwhile lower than "FER threshold 3", the value of "FER 2 and Quality Level N" is incremented by one. GBFD-116801Voice Quality Index (Uplink VQI) Interval Type 0~1000 0~1000 per millNone 4 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FERSTATTH3 FER Threshold 3 BSC6900 SET GCELLOTHEXT(Optional) If the FER carried in the MR received is greater than "FER threshold 3" but meanwhile lower than "FER threshold 4", the value of "FER 3 and Quality Level N" is incremented by one. GBFD-116801Voice Quality Index (Uplink VQI) Interval Type 0~1000 0~1000 per millNone 8 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FERSTATTH4 FER Threshold 4 BSC6900 SET GCELLOTHEXT(Optional) If the FER carried in the MR received is greater than "FER threshold 4" but meanwhile lower than "FER threshold 5", the value of "FER 4 and Quality Level N" is incremented by one. GBFD-116801Voice Quality Index (Uplink VQI) Interval Type 0~1000 0~1000 per millNone 16 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FERSTATTH5 FER Threshold 5 BSC6900 SET GCELLOTHEXT(Optional) If the FER carried in the MR received is greater than "FER threshold 5" but meanwhile lower than "FER threshold 6", the value of "FER 5 and Quality Level N" is incremented by one. GBFD-116801Voice Quality Index (Uplink VQI) Interval Type 0~1000 0~1000 per millNone 32 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FERSTATTH6 FER Threshold 6 BSC6900 SET GCELLOTHEXT(Optional) If the FER carried in the MR received is greater than "FER threshold 6" but meanwhile lower than "FER threshold 7", the value of "FER 6 and Quality Level N" is incremented by one. GBFD-116801Voice Quality Index (Uplink VQI) Interval Type 0~1000 0~1000 per millNone 64 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FERSTATTH7 FER Threshold 7 BSC6900 SET GCELLOTHEXT(Optional) If the FER carried in the MR received is greater than "FER threshold 7", the value of "FER 7 and Quality Level N" is incremented by one. GBFD-116801Voice Quality Index (Uplink VQI) Interval Type 0~1000 0~1000 per millNone 128 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FHMODE Frequency hopping mode BSC6900 SET GCELLHOPTP(Optional)SET GCELLHOPQUICKSETUP(Mandatory) Frequency hopping mode. Frequency hopping assists in interference averaging and frequency diversity. GBFD-113701Frequency Hopping (RF hopping, baseband hopping) Enumeration Type NO_FH(No frequency hopping), BaseBand_FH(Baseband frequency hopping), RF_FH(RF frequency hopping), Hybrid_FH(Hybrid frequency hopping) NO_FH, BaseBand_FH, RF_FH, Hybrid_FH None None None Cell None Read & Write Y Cell Less than 5 minutes Before you set this parameter, deactivate the cell. After you set this parameter, activate the cell.
FILE File Name BSC6900 EXP LOG(Optional) The file name cannot contain the path and suffix, and suffix is automatically added. The file name is composed of English letters, numerals, and common symbols, and the characters (@, #, !, %, ^, &, *, [, ], /, \, ', and ") cannot appear in the file name. GBFD-111203MRFD-210305 O&M of BSCSecurity Management String Type None 1~128 characters None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FILE Target File Path BSC6900 ZIP FILE(Mandatory) Path of the target file GBFD-111203MRFD-210401 O&M of BSCBSC/RNC Software Management String Type None 1~200 characters None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FileName File Name BSC6900 BKP LOGDB(Optional) Name of the backup file. The file name is composed of English letters, numerals, and common symbols, and the characters (@, #, !, %, ^, &, *, [, ], /, \, ', and ") cannot appear in the file name. GBFD-111203MRFD-210305 O&M of BSCSecurity Management String Type None 0~200 characters None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FILEPATH Export File Path BSC6900 EXP CFGMML(Optional)EXP GCELLTEMPLATE(Optional) Path to save the exported file. The path must be a valid path on the OMU server. If the OMU runs the LINUX system, the input path must start with the symbol "/" or "\", for example, "/mml". If the OMU runs the WINDOWS system, the input path can be a full path (for example, "D:\mml") or a relative path (for example, "/mml"). If the relative path is used, the root directory is same as that of the OMU installation directory. That is, if the OMU software is installed in disk D, the exported file is saved in "D:/mml". MRFD-210301Configuration Management String Type None 0~128 characters None None None BSC6900None Read & Write Not involved Not involved Not involved None
filetype Log File Type BSC6900 EXP ALMLOG(Optional) Type of the alarm log file to be exported GBFD-111203MRFD-210304 O&M of BSCFaulty Management Enumeration Type txt(.txt file), csv(.csv file) txt, csv None .txt file .txt file RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FILTERKEY Filter Type Of Frame Log BSC6900 SET LOGCFG(Optional) Filter Type Of Frame Log MRFD-210304Faulty Management Enumeration Type TASKID~1CMDCODE TASKID~1CMDCODE~2 None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FILTERWNDSIZE Filter Window Size BSC6900 SET GCELLNC2PARA(Optional) Number of forward values when the signal strength of the neighboring cell is processed on the average measurement report. The greater the value, the greater the weight of the previous circuit level; otherwise, the greater the weight of the current circuit level. GBFD-116201Network-Controlled Cell Reselection (NC2) Interval Type 0~32 0~32 None None 6 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FIN Final BSC6900 EXP LOG(Optional) Execution result.If you select "FALSE", only the records of failed operations are displayed. If you select "TRUE", only the records of successful operations are displayed. If this parameter is not specified, all the records are displayed. GBFD-111203MRFD-210305 O&M of BSCSecurity Management Enumeration Type FALSE(Failed), TRUE(Succeed) FALSE, TRUE None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FINESTEPPCALLOWED 0.2dB Power Control Enable BSC6900 SET GCELLPWR3(Optional) Whether to enable 0.2 dB downlink power control. This power control function improves the power control precision. GBFD-117601HUAWEI III Power Control Algorithm Enumeration Type NO(No), YES(Yes)NO, YES None None NO Cell This parameter is valid only when "PWRCTRLSW" in "SET GCELLPWRBASIC" is set to PWR3. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FIRESET Fire-extinguishing Equipment BSC6900 SET BTSOUTPUT(Optional) Whether to start the fire-extinguishing equipment of the BTS.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. GBFD-111202O&M of BTS Enumeration Type INACTIVE(Inactive), ACTIVE(Active) INACTIVE, ACTIVE None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FIXABISPRIORABISLOADTHRED Fix Abis Prior Choose Load Thred BSC6900 SET BTSFLEXABISPARA(Optional) This parameter specifies the static Abis resource load threshold. If the static Abis resource load is less than the static Abis resource load threshold, the TCHF is preferentially allocated. Otherwise, whether the TCHF or the TCHH should be preferentially allocated is determined by the dynamic Abis resource load. GBFD-117301Flex Abis Interval Type 0~100 0~100 per cent None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FlashAlmClrThd Flash Alarm Clear Threshold BSC6900 SET BTSALMFLASHTHD(Optional) Time threshold for delaying the report of a clear alarm. If the alarm recurs within the time specified by this parameter after it is cleared, the clear alarm is not reported. Otherwise, the clear alarm is reported. If this parameter is set to 0, the clear alarm is reported immediately when the alarm is cleared. MRFD-210304Faulty Management Interval Type 0~65534 0~65534 s 0 None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FlashAlmOccurThd Flash Alarm Occur Threshold BSC6900 SET BTSALMFLASHTHD(Optional) Time threshold for delaying the report of an alarm. If the alarm is cleared within the time specified by this parameter, the alarm is not reported. Otherwise, the alarm is reported. If this parameter is set to 0, the alarm is reported immediately when the alarm occurs. MRFD-210304Faulty Management Interval Type 0~65534 0~65534 s 0 None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FlashFilterEn Flash Filter Enable BSC6900 SET BTSALMFLASHTW(Optional) Whether to enable the filtering of the intermittent alarms. If the value of this parameter is "DISABLE", "Flash Statis Alarm Raise Time Window" and "Flash Statis Alarm Clear Time" are invalid. MRFD-210304Faulty Management Enumeration Type DISABLE(DISABLE), ENABLE(ENABLE) DISABLE, ENABLE None 1 None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FlashStatisAlmClrTW Flash Statis Alarm Clear Time Window BSC6900 SET BTSALMFLASHTW(Optional) Time window for observing the clearance of the intermittent alarms. In this time window, the BTS statistical alarm is cleared if the occurrence of the intermittent alarm meets the related threshold. MRFD-210304Faulty Management Interval Type 60~65534 60~65534 s 900 None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FlashStatisAlmOccurTW Flash Statis Alarm Raise Time Window BSC6900 SET BTSALMFLASHTW(Optional) Time window for observing the intermittent alarms generated during the statistical period. In this time window, the BTS statistical alarm is reported if the occurrence of the intermittent alarm meets the related threshold. MRFD-210304Faulty Management Interval Type 60~65534 60~65534 s 900 None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FLEXABISMODE Flex Abis Mode BSC6900 ADD BTS(Optional) Service timeslot assignment mode for the BTS. If this parameter is set to FIX_16K_ABIS, the BSC assigns a fixed Abis transmission timeslot to a TCH. If this parameter is set to FLEX_ABIS, the BSC assigns an Abis transmission timeslot dynamically to a TCH (except the static PDCH) to increase the resource utilization. If this parameter is set to SEMI_ABIS, the BTS to which a TCH belongs assigns a fixed Abis transmission timeslot to the TCH while the upper-level BTS set to FLEX_ABIS assigns an Abis transmission timeslot dynamically to the TCH. This mode applies where old and new BTSs are cascaded. HDLC and IP BTS is not support this parameter. GBFD-117301Flex Abis Enumeration Type FIX_16K_ABIS(Fix Abis), FLEX_ABIS(Flex Abis), SEMI_ABIS(Semisolid Abis) FIX_16K_ABIS, FLEX_ABIS, FIX_64K_ABIS None FIX_16K_ABISFIX_16K_ABIS BTS None Read & Write Y BTS Less than 5 minutes None
FLEXMAIO Start Flex MAIO Switch BSC6900 ADD GCELL(Optional) Whether to enable the function of Flex mobile allocation index offset (MAIO). In the tight frequency reuse case of the GSM system, adjacent-channel interference and co-channel interference easily occur between channels. If the frequency hopping function and the Flex MAIO function are enabled in a cell, adjacent-channel or co-channel interference between channels can be reduced partially. GBFD-117001Flex MAIO Enumeration Type OFF(Off), ON(On) OFF, ON None OFF When tight frequency reuse is used, the recommended value is ON. Cell This parameter is valid when "FHMODE" in the "SET GCELLHOPTP" command is not set to NO_FH. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FLEXTSCSWITCH Flex TSC Switch BSC6900 SET GCELLSOFT(Optional) Whether to enable the function of the Flex training sequence code (TSC). If the value of this parameter is ON and the BTS supports the Flex TSC function, the BSS dynamically allocates TSCs to hopping frequencies for improving the security of calls. GBFD-113521GBFD-118201 Encrypted Network ManagementSoft-Synchronized Network Enumeration Type OFF(Off), ON(On) OFF, ON None None OFF Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FlowCountPeriodTicks Flux Measurement Period BSC6900 SET BSCPSSOFTPARA(Optional) Period of collecting the traffic statistics. GBFD-119501Adaptive Adjustment of Uplink and Downlink Channels Interval Type 0~65535 0~65535 ms None 4500 BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FLOWCOUNTPERIODTSRAPIDADJ Fast Flux Measurement Period BSC6900 SET BSCPSSOFTPARA(Optional) Fast flux measurement period. The ratio of the uplink flow to the downlink flow is calculated at the interval specified by this parameter to determine the current service type. GBFD-119501Adaptive Adjustment of Uplink and Downlink Channels Interval Type 0~65535 0~65535 ms None 1000 BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved If this parameter is set to a small value, error is likely to occur during the detection of the burst packets.
FLOWCTRLSWITCH Flow control switch BSC6900 SET OPT(Optional) Port flow control switch None None Enumeration Type OFF(OFF), ON(ON) OFF, ON None None OFF Board None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
FLOWCTRLSWITCH Flow control switch BSC6900 SET ETHPORT(Optional) Port flow control switch None None Enumeration Type OFF(OFF), ON(ON) OFF, ON None None ON Ethernet port None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FLOWCTRLSWITCH Flow control switch BSC6900 ADD PPPLNK(Optional) Link flow control switch GBFD-118611GBFD-118622 Abis IP over E1/T1A IP over E1/T1 Enumeration Type OFF(OFF), ON(ON) OFF, ON None ON ON PPP link None Read & Write Y BSC6900 Interrupt the service until negotiate successfully again. Negotiation can succeed only when the configuration is consistent on the local and peer ends.
FLOWCTRLSWITCH Flow control switch BSC6900 ADD MPGRP(Optional) Link flow control switch GBFD-118611GBFD-118622 Abis IP over E1/T1A IP over E1/T1 Enumeration Type OFF(OFF), ON(ON) OFF, ON None ON ON MP groupNone Read & Write N (No impact on the UE in idle mode) Not involved Not involved Negotiation can succeed only when the configuration is consistent on the local and peer ends.
FLOWCTRLSWITCH Flow control switch BSC6900 ADD IPLOGICPORT(Optional) Logical port flow control switch None None Enumeration Type OFF(OFF), ON(ON) OFF, ON None ON ON IP logical port None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FLOWCTRLSWITCH Flow control switch BSC6900 ADD ETHTRK(Optional) Port flow control switch MRFD-210103Link aggregation Enumeration Type OFF(OFF), ON(ON) OFF, ON None ON ON Ethernet port None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
FLOWCTRLSWITCH Flow control switch BSC6900 SET BTSABISPRIMAP(Optional) Specified port flow control switch None None Enumeration Type OFF(OFF), ON(ON) OFF, ON None None None BTS None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
FLTPARAA1 Filter Parameter A1 BSC6900 SET GCELLHOEMG(Optional) One of the nine parameters (filter parameters A1 to A8 and filter parameter B) used to configure the filter for determining whether the received signal level drops rapidly. The computation formula is as follows: C1(nt) = A1 x C(nt) + A2 x C(nt-t) + A3 x C(nt-2t) + ... + A8 x C(nt-7t)If C1(nt) is less than B and C(nt) is less than the threshold for edge handover, the signal level is considered dropping rapidly.In the formula, A1 to A8 are filter parameters A1 to A8 minus 10 and B is the negative of filter parameter B. C(nt) indicates the received signal level in the uplink measurement report of the serving cell received at time nt.Setting the filter helps to configure the maximum allowed signal level drop degree. GBFD-110601HUAWEI I Handover Interval Type 0~20 0~20 None None 10 Cell This parameter is valid only when "RXQCKFALLHOEN" in "SET GCELLHOBASIC" is set to YES. The following condition must be met: "FLTPARAA1" + "FLTPARAA2" + "FLTPARAA3" + "FLTPARAA4" + "FLTPARAA5" + "FLTPARAA6" + "FLTPARAA7" + "FLTPARAA8" = 80. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FLTPARAA2 Filter Parameter A2 BSC6900 SET GCELLHOEMG(Optional) One of the nine parameters (filter parameters A1 to A8 and filter parameter B) used to configure the filter for determining whether the received signal level drops rapidly. The computation formula is as follows: C1(nt) = A1 x C(nt) + A2 x C(nt-t) + A3 x C(nt-2t) + ... + A8 x C(nt-7t)If C1(nt) is less than B and C(nt) is less than the threshold for edge handover, the signal level is considered dropping rapidly.In the formula, A1 to A8 are filter parameters A1 to A8 minus 10 and B is the negative of filter parameter B. C(nt) indicates the received signal level in the uplink measurement report of the serving cell received at time nt.Setting the filter helps to configure the maximum allowed signal level drop degree. GBFD-110601HUAWEI I Handover Interval Type 0~20 0~20 None None 10 Cell This parameter is valid only when "RXQCKFALLHOEN" in "SET GCELLHOBASIC" is set to YES. The following condition must be met: "FLTPARAA1" + "FLTPARAA2" + "FLTPARAA3" + "FLTPARAA4" + "FLTPARAA5" + "FLTPARAA6" + "FLTPARAA7" + "FLTPARAA8" = 80. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FLTPARAA3 Filter Parameter A3 BSC6900 SET GCELLHOEMG(Optional) One of the nine parameters (filter parameters A1 to A8 and filter parameter B) used to configure the filter for determining whether the received signal level drops rapidly. The computation formula is as follows: C1(nt) = A1 x C(nt) + A2 x C(nt-t) + A3 x C(nt-2t) + ... + A8 x C(nt-7t)If C1(nt) is less than B and C(nt) is less than the threshold for edge handover, the signal level is considered dropping rapidly.In the formula, A1 to A8 are filter parameters A1 to A8 minus 10 and B is the negative of filter parameter B. C(nt) indicates the received signal level in the uplink measurement report of the serving cell received at time nt.Setting the filter helps to configure the maximum allowed signal level drop degree. GBFD-110601HUAWEI I Handover Interval Type 0~20 0~20 None None 10 Cell This parameter is valid only when "RXQCKFALLHOEN" in "SET GCELLHOBASIC" is set to YES. The following condition must be met: "FLTPARAA1" + "FLTPARAA2" + "FLTPARAA3" + "FLTPARAA4" + "FLTPARAA5" + "FLTPARAA6" + "FLTPARAA7" + "FLTPARAA8" = 80. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FLTPARAA4 Filter Parameter A4 BSC6900 SET GCELLHOEMG(Optional) One of the nine parameters (filter parameters A1 to A8 and filter parameter B) used to configure the filter for determining whether the received signal level drops rapidly. The computation formula is as follows: C1(nt) = A1 x C(nt) + A2 x C(nt-t) + A3 x C(nt-2t) + ... + A8 x C(nt-7t)If C1(nt) is less than B and C(nt) is less than the threshold for edge handover, the signal level is considered dropping rapidly.In the formula, A1 to A8 are filter parameters A1 to A8 minus 10 and B is the negative of filter parameter B. C(nt) indicates the received signal level in the uplink measurement report of the serving cell received at time nt.Setting the filter helps to configure the maximum allowed signal level drop degree. GBFD-110601HUAWEI I Handover Interval Type 0~20 0~20 None None 10 Cell This parameter is valid only when "RXQCKFALLHOEN" in "SET GCELLHOBASIC" is set to YES. The following condition must be met: "FLTPARAA1" + "FLTPARAA2" + "FLTPARAA3" + "FLTPARAA4" + "FLTPARAA5" + "FLTPARAA6" + "FLTPARAA7" + "FLTPARAA8" = 80. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FLTPARAA5 Filter Parameter A5 BSC6900 SET GCELLHOEMG(Optional) One of the nine parameters (filter parameters A1 to A8 and filter parameter B) used to configure the filter for determining whether the received signal level drops rapidly. The computation formula is as follows: C1(nt) = A1 x C(nt) + A2 x C(nt-t) + A3 x C(nt-2t) + ... + A8 x C(nt-7t)If C1(nt) is less than B and C(nt) is less than the threshold for edge handover, the signal level is considered dropping rapidly.In the formula, A1 to A8 are filter parameters A1 to A8 minus 10 and B is the negative of filter parameter B. C(nt) indicates the received signal level in the uplink measurement report of the serving cell received at time nt.Setting the filter helps to configure the maximum allowed signal level drop degree. GBFD-110601HUAWEI I Handover Interval Type 0~20 0~20 None None 10 Cell This parameter is valid only when "RXQCKFALLHOEN" in "SET GCELLHOBASIC" is set to YES. The following condition must be met: "FLTPARAA1" + "FLTPARAA2" + "FLTPARAA3" + "FLTPARAA4" + "FLTPARAA5" + "FLTPARAA6" + "FLTPARAA7" + "FLTPARAA8" = 80. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FLTPARAA6 Filter Parameter A6 BSC6900 SET GCELLHOEMG(Optional) One of the nine parameters (filter parameters A1 to A8 and filter parameter B) used to configure the filter for determining whether the received signal level drops rapidly. The computation formula is as follows: C1(nt) = A1 x C(nt) + A2 x C(nt-t) + A3 x C(nt-2t) + ... + A8 x C(nt-7t)If C1(nt) is less than B and C(nt) is less than the threshold for edge handover, the signal level is considered dropping rapidly.In the formula, A1 to A8 are filter parameters A1 to A8 minus 10 and B is the negative of filter parameter B. C(nt) indicates the received signal level in the uplink measurement report of the serving cell received at time nt.Setting the filter helps to configure the maximum allowed signal level drop degree. GBFD-110601HUAWEI I Handover Interval Type 0~20 0~20 None None 10 Cell This parameter is valid only when "RXQCKFALLHOEN" in "SET GCELLHOBASIC" is set to YES. The following condition must be met: "FLTPARAA1" + "FLTPARAA2" + "FLTPARAA3" + "FLTPARAA4" + "FLTPARAA5" + "FLTPARAA6" + "FLTPARAA7" + "FLTPARAA8" = 80. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FLTPARAA7 Filter Parameter A7 BSC6900 SET GCELLHOEMG(Optional) One of the nine parameters (filter parameters A1 to A8 and filter parameter B) used to configure the filter for determining whether the received signal level drops rapidly. The computation formula is as follows: C1(nt) = A1 x C(nt) + A2 x C(nt-t) + A3 x C(nt-2t) + ... + A8 x C(nt-7t)If C1(nt) is less than B and C(nt) is less than the threshold for edge handover, the signal level is considered dropping rapidly.In the formula, A1 to A8 are filter parameters A1 to A8 minus 10 and B is the negative of filter parameter B. C(nt) indicates the received signal level in the uplink measurement report of the serving cell received at time nt.Setting the filter helps to configure the maximum allowed signal level drop degree. GBFD-110601HUAWEI I Handover Interval Type 0~20 0~20 None None 10 Cell This parameter is valid only when "RXQCKFALLHOEN" in "SET GCELLHOBASIC" is set to YES. The following condition must be met: "FLTPARAA1" + "FLTPARAA2" + "FLTPARAA3" + "FLTPARAA4" + "FLTPARAA5" + "FLTPARAA6" + "FLTPARAA7" + "FLTPARAA8" = 80. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FLTPARAA8 Filter Parameter A8 BSC6900 SET GCELLHOEMG(Optional) One of the nine parameters (filter parameters A1 to A8 and filter parameter B) used to configure the filter for determining whether the received signal level drops rapidly. The computation formula is as follows: C1(nt) = A1 x C(nt) + A2 x C(nt-t) + A3 x C(nt-2t) + ... + A8 x C(nt-7t)If C1(nt) is less than B and C(nt) is less than the threshold for edge handover, the signal level is considered dropping rapidly.In the formula, A1 to A8 are filter parameters A1 to A8 minus 10 and B is the negative of filter parameter B. C(nt) indicates the received signal level in the uplink measurement report of the serving cell received at time nt.Setting the filter helps to configure the maximum allowed signal level drop degree. GBFD-110601HUAWEI I Handover Interval Type 0~20 0~20 None None 10 Cell This parameter is valid only when "RXQCKFALLHOEN" in "SET GCELLHOBASIC" is set to YES. The following condition must be met: "FLTPARAA1" + "FLTPARAA2" + "FLTPARAA3" + "FLTPARAA4" + "FLTPARAA5" + "FLTPARAA6" + "FLTPARAA7" + "FLTPARAA8" = 80. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FLTPARAB Filter Parameter B BSC6900 SET GCELLHOEMG(Optional) Trend of the received signal level of the cell during a period. This parameter helps to configure the filter for determining whether the received signal level drops rapidly. If this parameter is higher, a more rapid signal level drop is required to trigger the handover due to rapid signal level drop. GBFD-110601HUAWEI I Handover Interval Type 0~200 0~200 None None 0 Cell This parameter is valid only when "RXQCKFALLHOEN" in "SET GCELLHOBASIC" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FLUSHTRANSFERSWITCH FLUSH-LL PDU Transfer Switch BSC6900 SET BSCPSSOFTPARA(Optional) Whether to instruct the BSC to discard or buffer the data of this MS when the SGSN detects the FLUSH-LL flow originated by the MS during cell reselection, cell update, or routing area update. GBFD-114101GPRS Enumeration Type CLOSE(Close), OPEN(Open) CLOSE, OPEN None None OPEN BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FMSMAXOPCC MS_TXPWR_MAX_CCH BSC6900 SET GCELLCCCH(Optional) Maximum transmit power level of MSs. As one of the cell reselection parameters in system message 3, this parameter is used to control the transmit power of MSs. For details, see GSM Rec. 05.05.In a GSM900 cell, the maximum power control level of an MS ranges from 0 to 19, corresponding respectively to the following values (unit: dBm): 43, 41, 39, 37, 35, 33, 31, 29, 27, 25, 23, 21, 19, 17, 15, 13, 11, 9, 7, and 5.Generally, the maximum transmit power supported by an MS is level 5 (corresponding to 33 dBm). The minimum transmit power supported by an MS is level 19 (corresponding to 5 dBm). Other transmit power levels are reserved for high-power MSs.In a GSM1800 or GSM1900 cell, the maximum power control level of an MS ranges from 0 to 31, corresponding respectively to the following values (unit: dBm): 30, 28, 26, 24, 22, 20, 18, 16, 14, 12, 10, 8, 6, 4, 2, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 36, 34, and 32. Generally, the maximum transmit power supported by an MS is level 0 (corresponding to 30 dBm). T GBFD-111003Radio Common Channel Management Interval Type 0~19 0~19 None None 5 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The default value of "MS_TXPWR_MAX_CCH" in the GSM900 and GSM850 cells is 5; the default value of "MS_TXPWR_MAX_CCH" in the DCS1800 and PCS1900 cells is 0.
FMUTYPE FMU Board Type BSC6900 SET BTSFMUABP(Optional) Type of the FMUA board GBFD-111202O&M of BTS Enumeration Type INDOOR(Indoor), OUTDOOR(Outdoor) INDOOR, OUTDOOR None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FN File Name BSC6900 EXP ELABEL(Optional) Name of the electronic label file MRFD-210301Configuration Management String Type None 0~128 characters None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved In "EXP ELABEL", the "FN" parameter cannot be a space or any of the following characters: '@', '#', '!', '%', '^', '&', '*', '[', ']', '\'', '\\'.
FN File Name BSC6900 DLD LICENSE(Mandatory)ULD LICENSE(Mandatory) Name of the fileGBFD-111203MRFD-210401 O&M of BSCBSC/RNC Software Management String Type None 1~100 characters None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FN File Name BSC6900 EXP DEVFILE(Optional) Name of the file. GBFD-111203O&M of BSC String Type None 1~128 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None.
FN File Name BSC6900 EXP CFGMML(Optional)BKP DB(Optional)EXP GCELLTEMPLATE(Optional) Name of the file. The following special characters are not allowed in the file name: \, /, :, *, ?, ", <, >, and |. MRFD-210301Configuration Management String Type None 0~128 characters None None None BSC6900None Read & Write Not involved Not involved Not involved None
FN File Name BSC6900 CHK DATA2LIC(Optional) Name of the specified file. By default, the file is in the OMU active-area path \ftp\license folder. MRFD-210403License Management String Type None 0~100 characters None None none BSC6900None Read & Write Not involved Not involved Not involved None
FN File Name BSC6900 DLD BTSSW(Mandatory)DLD RETANTCFG(Mandatory)EXP BTSDEVFILE(Optional)LOD RETANTCFG(Mandatory)ULD BTSLOG(Mandatory) Name of the software to be downloaded GBFD-111202O&M of BTS String Type None 1~256 characters None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FN File Name BSC6900 DLD BTSPATCH(Optional) Name of the software to be downloaded.The file name must be with the extension of *.zip.If you do not enter the file name, all the valid files in the directory are downloaded. These valid files are extracted from the patch package. GBFD-111202O&M of BTS String Type None 1~256 characters None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FORBIDEDGU Allow E Down G Up Switch BSC6900 SET BSCPSSOFTPARA(Optional) Switch specifying whether to allow the downlink EGPRS TBF and the uplink GPRS TBF to share the same channel. On: allow the downlink EGPRS TBF and the uplink GPRS TBF to share the same channel; Off: prohibit the downlink EGPRS TBF and the uplink GPRS TBF sharing the same channel. GBFD-114201EGPRS Enumeration Type OPEN(Open), CLOSE(Close) OPEN, CLOSE None None OPEN BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FORBIDNO7FLASHDISC Anti DPC Intermittent Disconnect Timer BSC6900 ADD GCNNODE(Optional) Length of the timer for determining the intermittent disconnection of the link to the DPC. GBFD-111804A Interface Protocol Process Interval Type 1~300 1~300 s 15 15 MSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
Force_Limit_Time Force Limit Time BSC6900 SET TCPARA(Optional) Time limit for restraining the noise level GBFD-115601Automatic Level Control (ALC) Interval Type 0~30 0~30 s None 0 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
Force2Phase Force MS Two-phase Access BSC6900 SET BSCPSSOFTPARA(Optional) Whether the forced phase-2 access is allowed for the MS. GBFD-114101GPRS Enumeration Type Close(Close), Open(Open) Close, Open None None Close BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FORCEDCELLEFRSWITCH Allow Forced EFR in Cell BSC6900 SET GCELLSOFT(Optional) Whether to forcibly enable the EFR function. When this parameter is set to YES, if both the MS and the BSC support the enhanced full rate (EFR), the BSC forcibly enables the EFR function even if the MSC does not support the function. GBFD-110501Call Control Enumeration Type NO(No), YES(Yes)NO, YES None None NO Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved When this parameter is set to YES, during the channel activation of the BSC, if the allocated channel speech version is full rate speech version 1 whereas the MS supports full rate speech version 2, the BSC changes the speech version to full rate speech version 2 and sends it to the BTS. For the MSC, however, this change is shielded. The speech version viewed at the MSC side is still full rate speech version 1.
FORCEMSACCESS Force MS to Send Ho Access SWITCH BSC6900 SET GCELLSOFT(Optional) Whether an MS is forced to send a Handover Access message, which is indicated by an information element in the handover command. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Enumeration Type NO(No), YES(Yes)NO, YES None None YES Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FPN Dest Father BTS Port No. BSC6900 ADD BTSAUTOPLAN(Mandatory) Port No. of the father BTS connected with the BTS GBFD-111202O&M of BTS Interval Type 0~31 0~31 None None None BTS None Read & Write Y BTS Less than 5 minutes None
FPN Dest Father BTS Port No. BSC6900 ADD BTSCONNECT(Mandatory) Number of the port for the destination father BTS GBFD-111202O&M of BTS Interval Type 0~7 0~7 None None None BTS None Read & Write Y BTS Less than 5 minutes This parameter can be modified only when the BTS is deactivated.
FPTIMER FPTIMER[ms] BSC6900 ADD IPMUX(Optional) Maximum multiplex delay. This parameter is used for the system to send the multiplexed data without waiting for multiplexing other packets when the duration for buffering the data exceeds this delay. In this way, overlong delay can be prevented. GBFD-118604GBFD-118610 Abis MUXUDP MUX for A Transmission Interval Type 1~30 1~30 ms 2 2 IP path None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The adjacent node ID must be configured.
FQBSICOPTSWITCH Freq. and BSIC Optimize Switch BSC6900 SET BTSAUTOPLANCFG(Optional) Whether to generate the frequency and BSIC by using the automatic optimization algorithm GBFD-510701Compact BTS Automatic Configuration and Planning Enumeration Type OFF(OFF), ON(ON) OFF, ON None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FQBSICSWITCH Freq. and BSIC Plan Switch BSC6900 SET BTSAUTOPLANCFG(Optional) If this switch is on, it indicates that the frequency and BSIC are generated automatically. If this switch is off, it indicates that the data must be configured manually. GBFD-510701Compact BTS Automatic Configuration and Planning Enumeration Type OFF(OFF), ON(ON) OFF, ON None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FQBSICSWITCH1 Freq. and BSIC Plan Switch BSC6900 SET BTSAUTOPLANCFG(Optional) If this switch is on, it indicates that the frequency and BSIC are generated automatically. If this switch is off, it indicates that the data must be configured manually. GBFD-510701Compact BTS Automatic Configuration and Planning Enumeration Type OFF(OFF), ON(ON) OFF, ON None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FRAGSIZE MP flake size BSC6900 ADD MPGRP(Optional) MP segment size GBFD-118611GBFD-118622 Abis IP over E1/T1A IP over E1/T1 Interval Type 128~1024 128~1024 byte 256 None MP groupNone Read & Write N (No impact on the UE in idle mode) Not involved Not involved No_HC: disable the header compression function; RTP/UDP/IP_HC: enable the RTP/UDP/IP/PPP function
FRAMEOFFSET Frame Offset [Frame No.] BSC6900 SET BTSEXCURSION(Mandatory)SET BSCSYNCOFF(Mandatory) Frame offset of the BTS clock. GBFD-118201Soft-Synchronized Network Interval Type -2715647~2715647-2715647~2715647 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None.
FRAMEOFFSET Frame Offset BSC6900 SET GCELLOTHEXT(Optional) Frame offset. The frame offset technology arranges the frame numbers of different cells under the same BTS to be different from one another by one frame offset. Thus, the FCH and SCH signals of neighboring cells do not appear in the same frame, which is helpful for the coding of an MS. If the value of this parameter is 0, the cell is not offset. If the value is 255, this parameter is not sent. If the parameter is set to a value except for 0 and 255, the handover of the cell must be changed from the synchronous mode to the asynchronous mode. For BTS3001C, BTS3X, BTS3002C, and double-transceiver BTSs, the frame offset can be predicted according to the value of this parameter. MRFD-210301Configuration Management Interval Type 0~255 0~255 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved For a BTS of the BTS3X series, the value of this parameter is invalid.
FRDLDTX FR Use Downlink DTX BSC6900 SET GCELLBASICPARA(Optional) Whether the downlink discontinuous transmission (DTX) function is enabled for full rate (FR) calls. This function is also restricted by the DTX switch in the MSC. If the MSC allows the downlink DTX for calls and the value of this parameter is YES, the downlink DTX is enabled for FR calls of cells. GBFD-114801Discontinuous Transmission (DTX) Downlink Enumeration Type NO(No), YES(Yes)NO, YES None None YES Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FREQ Time Mode BSC6900 EXP LOG(Mandatory) Time mode used when the log is exported. "ONTIME" indicates the time between two exact time. "RELATIVE_T" indicates the time before the current time. GBFD-111203MRFD-210305 O&M of BSCSecurity Management Enumeration Type ONTIME(fixed_time), RELATIVE_T(relative_time) ONTIME, RELATIVE None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FREQ Time Mode BSC6900 ADD SUBTSK(Mandatory) Based on different requirements, you can set different time points for the scheduled task. Seven time modes are available: 1. ONTIME: When this parameter is set to "ONTIME", the command is executed once only at the specified time point. 2. DAILY_T: When this parameter is set to "DAILY_T", the command is executed every days. You can also set up to five time points for executing the command in the day. The default execution interval is one day. 3. DAILY_C: When this parameter is set to "DAILY_C", the command is executed every days. You can set the start time and end time in the day in which the command is executed. You can also set the time interval for executing the command in the day. The default execution interval is one day and the default time interval is 30 minutes. 4. WEEKLY_T: When this parameter is set to "WEEKLY_T", the command is executed every weeks. You can set the day in which the command is executed. You can also set up to five time points for executing the command in the day. The def GBFD-111203O&M of BSC Enumeration Type ONTIME(fixed_time), DAILY_T(day_based_scheduling), DAILY_C(day_based_duration), WEEKLY_T(week_based_scheduling), WEEKLY_C(week_based_duration), MONTHLY_T(month_based_scheduling), MONTHLY_C(month_based_duration) ONTIME, DAILY_T, DAILY_C, WEEKLY_T, WEEKLY_C, MONTHLY_T, MONTHLY_C None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FREQ Frequency BSC6900 ADD GTRX(Mandatory) Frequency of the TRX GBFD-110101Frequency Band Interval Type 0~1023 0~1023 None None None TRX None Read & Write Y Cell Less than 1 minute The value range of this parameter depends on the frequency range of the cell band.
FREQ1 Frequency 1 BSC6900 ADD GCELLFREQ(Optional)ADD GCELLMAGRP(Optional) Frequency 1 GBFD-110101Frequency Band Interval Type 0~1023 0~1023 None None None Cell None Read & Write Services are disrupted when the BCCH frequency in a cell is changed. Cell Less than 5 minutes If the BCCH frequency of a cell is changed, the BSC forcibly hands over the calls in this cell to another cell and then resets this cell.
FREQ10 Frequency 10 BSC6900 ADD GCELLFREQ(Optional)ADD GCELLMAGRP(Optional) Frequency 10 GBFD-110101Frequency Band Interval Type 0~1023 0~1023 None None None Cell None Read & Write Services are disrupted when the BCCH frequency in a cell is changed. Cell Less than 5 minutes If the BCCH frequency of a cell is changed, the BSC forcibly hands over the calls in this cell to another cell and then resets this cell.
FREQ11 Frequency 11 BSC6900 ADD GCELLFREQ(Optional)ADD GCELLMAGRP(Optional) Frequency 11 GBFD-110101Frequency Band Interval Type 0~1023 0~1023 None None None Cell None Read & Write Services are disrupted when the BCCH frequency in a cell is changed. Cell Less than 5 minutes If the BCCH frequency of a cell is changed, the BSC forcibly hands over the calls in this cell to another cell and then resets this cell.
FREQ12 Frequency 12 BSC6900 ADD GCELLFREQ(Optional)ADD GCELLMAGRP(Optional) Frequency 12 GBFD-110101Frequency Band Interval Type 0~1023 0~1023 None None None Cell None Read & Write Services are disrupted when the BCCH frequency in a cell is changed. Cell Less than 5 minutes If the BCCH frequency of a cell is changed, the BSC forcibly hands over the calls in this cell to another cell and then resets this cell.
FREQ13 Frequency 13 BSC6900 ADD GCELLFREQ(Optional)ADD GCELLMAGRP(Optional) Frequency 13 GBFD-110101Frequency Band Interval Type 0~1023 0~1023 None None None Cell None Read & Write Services are disrupted when the BCCH frequency in a cell is changed. Cell Less than 5 minutes If the BCCH frequency of a cell is changed, the BSC forcibly hands over the calls in this cell to another cell and then resets this cell.
FREQ14 Frequency 14 BSC6900 ADD GCELLFREQ(Optional)ADD GCELLMAGRP(Optional) Frequency 14 GBFD-110101Frequency Band Interval Type 0~1023 0~1023 None None None Cell None Read & Write Services are disrupted when the BCCH frequency in a cell is changed. Cell Less than 5 minutes If the BCCH frequency of a cell is changed, the BSC forcibly hands over the calls in this cell to another cell and then resets this cell.
FREQ15 Frequency 15 BSC6900 ADD GCELLFREQ(Optional)ADD GCELLMAGRP(Optional) Frequency 15 GBFD-110101Frequency Band Interval Type 0~1023 0~1023 None None None Cell None Read & Write Services are disrupted when the BCCH frequency in a cell is changed. Cell Less than 5 minutes If the BCCH frequency of a cell is changed, the BSC forcibly hands over the calls in this cell to another cell and then resets this cell.
FREQ16 Frequency 16 BSC6900 ADD GCELLFREQ(Optional)ADD GCELLMAGRP(Optional) Frequency 16 GBFD-110101Frequency Band Interval Type 0~1023 0~1023 None None None Cell None Read & Write Services are disrupted when the BCCH frequency in a cell is changed. Cell Less than 5 minutes If the BCCH frequency of a cell is changed, the BSC forcibly hands over the calls in this cell to another cell and then resets this cell.
FREQ17 Frequency 17 BSC6900 ADD GCELLFREQ(Optional)ADD GCELLMAGRP(Optional) Frequency 17 GBFD-110101Frequency Band Interval Type 0~1023 0~1023 None None None Cell None Read & Write Services are disrupted when the BCCH frequency in a cell is changed. Cell Less than 5 minutes If the BCCH frequency of a cell is changed, the BSC forcibly hands over the calls in this cell to another cell and then resets this cell.
FREQ18 Frequency 18 BSC6900 ADD GCELLFREQ(Optional)ADD GCELLMAGRP(Optional) Frequency 18 GBFD-110101Frequency Band Interval Type 0~1023 0~1023 None None None Cell None Read & Write Services are disrupted when the BCCH frequency in a cell is changed. Cell Less than 5 minutes If the BCCH frequency of a cell is changed, the BSC forcibly hands over the calls in this cell to another cell and then resets this cell.
FREQ19 Frequency 19 BSC6900 ADD GCELLFREQ(Optional)ADD GCELLMAGRP(Optional) Frequency 19 GBFD-110101Frequency Band Interval Type 0~1023 0~1023 None None None Cell None Read & Write Services are disrupted when the BCCH frequency in a cell is changed. Cell Less than 5 minutes If the BCCH frequency of a cell is changed, the BSC forcibly hands over the calls in this cell to another cell and then resets this cell.
FREQ2 Frequency 2 BSC6900 ADD GCELLFREQ(Optional)ADD GCELLMAGRP(Optional) Frequency 2 GBFD-110101Frequency Band Interval Type 0~1023 0~1023 None None None Cell None Read & Write Services are disrupted when the BCCH frequency in a cell is changed. Cell Less than 5 minutes If the BCCH frequency of a cell is changed, the BSC forcibly hands over the calls in this cell to another cell and then resets this cell.
FREQ20 Frequency 20 BSC6900 ADD GCELLFREQ(Optional)ADD GCELLMAGRP(Optional) Frequency 20 GBFD-110101Frequency Band Interval Type 0~1023 0~1023 None None None Cell None Read & Write Services are disrupted when the BCCH frequency in a cell is changed. Cell Less than 5 minutes If the BCCH frequency of a cell is changed, the BSC forcibly hands over the calls in this cell to another cell and then resets this cell.
FREQ21 Frequency 21 BSC6900 ADD GCELLFREQ(Optional)ADD GCELLMAGRP(Optional) Frequency 21 GBFD-110101Frequency Band Interval Type 0~1023 0~1023 None None None Cell None Read & Write Services are disrupted when the BCCH frequency in a cell is changed. Cell Less than 5 minutes If the BCCH frequency of a cell is changed, the BSC forcibly hands over the calls in this cell to another cell and then resets this cell.
FREQ22 Frequency 22 BSC6900 ADD GCELLFREQ(Optional)ADD GCELLMAGRP(Optional) Frequency 22 GBFD-110101Frequency Band Interval Type 0~1023 0~1023 None None None Cell None Read & Write Services are disrupted when the BCCH frequency in a cell is changed. Cell Less than 5 minutes If the BCCH frequency of a cell is changed, the BSC forcibly hands over the calls in this cell to another cell and then resets this cell.
FREQ23 Frequency 23 BSC6900 ADD GCELLFREQ(Optional)ADD GCELLMAGRP(Optional) Frequency 23 GBFD-110101Frequency Band Interval Type 0~1023 0~1023 None None None Cell None Read & Write Services are disrupted when the BCCH frequency in a cell is changed. Cell Less than 5 minutes If the BCCH frequency of a cell is changed, the BSC forcibly hands over the calls in this cell to another cell and then resets this cell.
FREQ24 Frequency 24 BSC6900 ADD GCELLFREQ(Optional)ADD GCELLMAGRP(Optional) Frequency 24 GBFD-110101Frequency Band Interval Type 0~1023 0~1023 None None None Cell None Read & Write Services are disrupted when the BCCH frequency in a cell is changed. Cell Less than 5 minutes If the BCCH frequency of a cell is changed, the BSC forcibly hands over the calls in this cell to another cell and then resets this cell.
FREQ25 Frequency 25 BSC6900 ADD GCELLFREQ(Optional)ADD GCELLMAGRP(Optional) Frequency 25 GBFD-110101Frequency Band Interval Type 0~1023 0~1023 None None None Cell None Read & Write Services are disrupted when the BCCH frequency in a cell is changed. Cell Less than 5 minutes If the BCCH frequency of a cell is changed, the BSC forcibly hands over the calls in this cell to another cell and then resets this cell.
FREQ26 Frequency 26 BSC6900 ADD GCELLFREQ(Optional)ADD GCELLMAGRP(Optional) Frequency 26 GBFD-110101Frequency Band Interval Type 0~1023 0~1023 None None None Cell None Read & Write Services are disrupted when the BCCH frequency in a cell is changed. Cell Less than 5 minutes If the BCCH frequency of a cell is changed, the BSC forcibly hands over the calls in this cell to another cell and then resets this cell.
FREQ27 Frequency 27 BSC6900 ADD GCELLFREQ(Optional)ADD GCELLMAGRP(Optional) Frequency 27 GBFD-110101Frequency Band Interval Type 0~1023 0~1023 None None None Cell None Read & Write Services are disrupted when the BCCH frequency in a cell is changed. Cell Less than 5 minutes If the BCCH frequency of a cell is changed, the BSC forcibly hands over the calls in this cell to another cell and then resets this cell.
FREQ28 Frequency 28 BSC6900 ADD GCELLFREQ(Optional)ADD GCELLMAGRP(Optional) Frequency 28 GBFD-110101Frequency Band Interval Type 0~1023 0~1023 None None None Cell None Read & Write Services are disrupted when the BCCH frequency in a cell is changed. Cell Less than 5 minutes If the BCCH frequency of a cell is changed, the BSC forcibly hands over the calls in this cell to another cell and then resets this cell.
FREQ29 Frequency 29 BSC6900 ADD GCELLFREQ(Optional)ADD GCELLMAGRP(Optional) Frequency 29 GBFD-110101Frequency Band Interval Type 0~1023 0~1023 None None None Cell None Read & Write Services are disrupted when the BCCH frequency in a cell is changed. Cell Less than 5 minutes If the BCCH frequency of a cell is changed, the BSC forcibly hands over the calls in this cell to another cell and then resets this cell.
FREQ3 Frequency 3 BSC6900 ADD GCELLFREQ(Optional)ADD GCELLMAGRP(Optional) Frequency 3 GBFD-110101Frequency Band Interval Type 0~1023 0~1023 None None None Cell None Read & Write Services are disrupted when the BCCH frequency in a cell is changed. Cell Less than 5 minutes If the BCCH frequency of a cell is changed, the BSC forcibly hands over the calls in this cell to another cell and then resets this cell.
FREQ30 Frequency 30 BSC6900 ADD GCELLFREQ(Optional)ADD GCELLMAGRP(Optional) Frequency 30 GBFD-110101Frequency Band Interval Type 0~1023 0~1023 None None None Cell None Read & Write Services are disrupted when the BCCH frequency in a cell is changed. Cell Less than 5 minutes If the BCCH frequency of a cell is changed, the BSC forcibly hands over the calls in this cell to another cell and then resets this cell.
FREQ31 Frequency 31 BSC6900 ADD GCELLFREQ(Optional)ADD GCELLMAGRP(Optional) Frequency 31 GBFD-110101Frequency Band Interval Type 0~1023 0~1023 None None None Cell None Read & Write Services are disrupted when the BCCH frequency in a cell is changed. Cell Less than 5 minutes If the BCCH frequency of a cell is changed, the BSC forcibly hands over the calls in this cell to another cell and then resets this cell.
FREQ32 Frequency 32 BSC6900 ADD GCELLFREQ(Optional)ADD GCELLMAGRP(Optional) Frequency 32 GBFD-110101Frequency Band Interval Type 0~1023 0~1023 None None None Cell None Read & Write Services are disrupted when the BCCH frequency in a cell is changed. Cell Less than 5 minutes If the BCCH frequency of a cell is changed, the BSC forcibly hands over the calls in this cell to another cell and then resets this cell.
FREQ33 Frequency 33 BSC6900 ADD GCELLFREQ(Optional)ADD GCELLMAGRP(Optional) Frequency 33 GBFD-110101Frequency Band Interval Type 0~1023 0~1023 None None None Cell None Read & Write Services are disrupted when the BCCH frequency in a cell is changed. Cell Less than 5 minutes If the BCCH frequency of a cell is changed, the BSC forcibly hands over the calls in this cell to another cell and then resets this cell.
FREQ34 Frequency 34 BSC6900 ADD GCELLFREQ(Optional)ADD GCELLMAGRP(Optional) Frequency 34 GBFD-110101Frequency Band Interval Type 0~1023 0~1023 None None None Cell None Read & Write Services are disrupted when the BCCH frequency in a cell is changed. Cell Less than 5 minutes If the BCCH frequency of a cell is changed, the BSC forcibly hands over the calls in this cell to another cell and then resets this cell.
FREQ35 Frequency 35 BSC6900 ADD GCELLFREQ(Optional)ADD GCELLMAGRP(Optional) Frequency 35 GBFD-110101Frequency Band Interval Type 0~1023 0~1023 None None None Cell None Read & Write Services are disrupted when the BCCH frequency in a cell is changed. Cell Less than 5 minutes If the BCCH frequency of a cell is changed, the BSC forcibly hands over the calls in this cell to another cell and then resets this cell.
FREQ36 Frequency 36 BSC6900 ADD GCELLFREQ(Optional)ADD GCELLMAGRP(Optional) Frequency 36 GBFD-110101Frequency Band Interval Type 0~1023 0~1023 None None None Cell None Read & Write Services are disrupted when the BCCH frequency in a cell is changed. Cell Less than 5 minutes If the BCCH frequency of a cell is changed, the BSC forcibly hands over the calls in this cell to another cell and then resets this cell.
FREQ37 Frequency 37 BSC6900 ADD GCELLFREQ(Optional)ADD GCELLMAGRP(Optional) Frequency 37 GBFD-110101Frequency Band Interval Type 0~1023 0~1023 None None None Cell None Read & Write Services are disrupted when the BCCH frequency in a cell is changed. Cell Less than 5 minutes If the BCCH frequency of a cell is changed, the BSC forcibly hands over the calls in this cell to another cell and then resets this cell.
FREQ38 Frequency 38 BSC6900 ADD GCELLFREQ(Optional)ADD GCELLMAGRP(Optional) Frequency 38 GBFD-110101Frequency Band Interval Type 0~1023 0~1023 None None None Cell None Read & Write Services are disrupted when the BCCH frequency in a cell is changed. Cell Less than 5 minutes If the BCCH frequency of a cell is changed, the BSC forcibly hands over the calls in this cell to another cell and then resets this cell.
FREQ39 Frequency 39 BSC6900 ADD GCELLFREQ(Optional)ADD GCELLMAGRP(Optional) Frequency 39 GBFD-110101Frequency Band Interval Type 0~1023 0~1023 None None None Cell None Read & Write Services are disrupted when the BCCH frequency in a cell is changed. Cell Less than 5 minutes If the BCCH frequency of a cell is changed, the BSC forcibly hands over the calls in this cell to another cell and then resets this cell.
FREQ4 Frequency 4 BSC6900 ADD GCELLFREQ(Optional)ADD GCELLMAGRP(Optional) Frequency 4 GBFD-110101Frequency Band Interval Type 0~1023 0~1023 None None None Cell None Read & Write Services are disrupted when the BCCH frequency in a cell is changed. Cell Less than 5 minutes If the BCCH frequency of a cell is changed, the BSC forcibly hands over the calls in this cell to another cell and then resets this cell.
FREQ40 Frequency 40 BSC6900 ADD GCELLFREQ(Optional)ADD GCELLMAGRP(Optional) Frequency 40 GBFD-110101Frequency Band Interval Type 0~1023 0~1023 None None None Cell None Read & Write Services are disrupted when the BCCH frequency in a cell is changed. Cell Less than 5 minutes If the BCCH frequency of a cell is changed, the BSC forcibly hands over the calls in this cell to another cell and then resets this cell.
FREQ41 Frequency 41 BSC6900 ADD GCELLFREQ(Optional)ADD GCELLMAGRP(Optional) Frequency 41 GBFD-110101Frequency Band Interval Type 0~1023 0~1023 None None None Cell None Read & Write Services are disrupted when the BCCH frequency in a cell is changed. Cell Less than 5 minutes If the BCCH frequency of a cell is changed, the BSC forcibly hands over the calls in this cell to another cell and then resets this cell.
FREQ42 Frequency 42 BSC6900 ADD GCELLFREQ(Optional)ADD GCELLMAGRP(Optional) Frequency 42 GBFD-110101Frequency Band Interval Type 0~1023 0~1023 None None None Cell None Read & Write Services are disrupted when the BCCH frequency in a cell is changed. Cell Less than 5 minutes If the BCCH frequency of a cell is changed, the BSC forcibly hands over the calls in this cell to another cell and then resets this cell.
FREQ43 Frequency 43 BSC6900 ADD GCELLFREQ(Optional)ADD GCELLMAGRP(Optional) Frequency 43 GBFD-110101Frequency Band Interval Type 0~1023 0~1023 None None None Cell None Read & Write Services are disrupted when the BCCH frequency in a cell is changed. Cell Less than 5 minutes If the BCCH frequency of a cell is changed, the BSC forcibly hands over the calls in this cell to another cell and then resets this cell.
FREQ44 Frequency 44 BSC6900 ADD GCELLFREQ(Optional)ADD GCELLMAGRP(Optional) Frequency 44 GBFD-110101Frequency Band Interval Type 0~1023 0~1023 None None None Cell None Read & Write Services are disrupted when the BCCH frequency in a cell is changed. Cell Less than 5 minutes If the BCCH frequency of a cell is changed, the BSC forcibly hands over the calls in this cell to another cell and then resets this cell.
FREQ45 Frequency 45 BSC6900 ADD GCELLFREQ(Optional)ADD GCELLMAGRP(Optional) Frequency 45 GBFD-110101Frequency Band Interval Type 0~1023 0~1023 None None None Cell None Read & Write Services are disrupted when the BCCH frequency in a cell is changed. Cell Less than 5 minutes If the BCCH frequency of a cell is changed, the BSC forcibly hands over the calls in this cell to another cell and then resets this cell.
FREQ46 Frequency 46 BSC6900 ADD GCELLFREQ(Optional)ADD GCELLMAGRP(Optional) Frequency 46 GBFD-110101Frequency Band Interval Type 0~1023 0~1023 None None None Cell None Read & Write Services are disrupted when the BCCH frequency in a cell is changed. Cell Less than 5 minutes If the BCCH frequency of a cell is changed, the BSC forcibly hands over the calls in this cell to another cell and then resets this cell.
FREQ47 Frequency 47 BSC6900 ADD GCELLFREQ(Optional)ADD GCELLMAGRP(Optional) Frequency 47 GBFD-110101Frequency Band Interval Type 0~1023 0~1023 None None None Cell None Read & Write Services are disrupted when the BCCH frequency in a cell is changed. Cell Less than 5 minutes If the BCCH frequency of a cell is changed, the BSC forcibly hands over the calls in this cell to another cell and then resets this cell.
FREQ48 Frequency 48 BSC6900 ADD GCELLFREQ(Optional)ADD GCELLMAGRP(Optional) Frequency 48 GBFD-110101Frequency Band Interval Type 0~1023 0~1023 None None None Cell None Read & Write Services are disrupted when the BCCH frequency in a cell is changed. Cell Less than 5 minutes If the BCCH frequency of a cell is changed, the BSC forcibly hands over the calls in this cell to another cell and then resets this cell.
FREQ49 Frequency 49 BSC6900 ADD GCELLFREQ(Optional)ADD GCELLMAGRP(Optional) Frequency 49 GBFD-110101Frequency Band Interval Type 0~1023 0~1023 None None None Cell None Read & Write Services are disrupted when the BCCH frequency in a cell is changed. Cell Less than 5 minutes If the BCCH frequency of a cell is changed, the BSC forcibly hands over the calls in this cell to another cell and then resets this cell.
FREQ5 Frequency 5 BSC6900 ADD GCELLFREQ(Optional)ADD GCELLMAGRP(Optional) Frequency 5 GBFD-110101Frequency Band Interval Type 0~1023 0~1023 None None None Cell None Read & Write Services are disrupted when the BCCH frequency in a cell is changed. Cell Less than 5 minutes If the BCCH frequency of a cell is changed, the BSC forcibly hands over the calls in this cell to another cell and then resets this cell.
FREQ50 Frequency 50 BSC6900 ADD GCELLFREQ(Optional)ADD GCELLMAGRP(Optional) Frequency 50 GBFD-110101Frequency Band Interval Type 0~1023 0~1023 None None None Cell None Read & Write Services are disrupted when the BCCH frequency in a cell is changed. Cell Less than 5 minutes If the BCCH frequency of a cell is changed, the BSC forcibly hands over the calls in this cell to another cell and then resets this cell.
FREQ51 Frequency 51 BSC6900 ADD GCELLFREQ(Optional)ADD GCELLMAGRP(Optional) Frequency 51 GBFD-110101Frequency Band Interval Type 0~1023 0~1023 None None None Cell None Read & Write Services are disrupted when the BCCH frequency in a cell is changed. Cell Less than 5 minutes If the BCCH frequency of a cell is changed, the BSC forcibly hands over the calls in this cell to another cell and then resets this cell.
FREQ52 Frequency 52 BSC6900 ADD GCELLFREQ(Optional)ADD GCELLMAGRP(Optional) Frequency 52 GBFD-110101Frequency Band Interval Type 0~1023 0~1023 None None None Cell None Read & Write Services are disrupted when the BCCH frequency in a cell is changed. Cell Less than 5 minutes If the BCCH frequency of a cell is changed, the BSC forcibly hands over the calls in this cell to another cell and then resets this cell.
FREQ53 Frequency 53 BSC6900 ADD GCELLFREQ(Optional)ADD GCELLMAGRP(Optional) Frequency 53 GBFD-110101Frequency Band Interval Type 0~1023 0~1023 None None None Cell None Read & Write Services are disrupted when the BCCH frequency in a cell is changed. Cell Less than 5 minutes If the BCCH frequency of a cell is changed, the BSC forcibly hands over the calls in this cell to another cell and then resets this cell.
FREQ54 Frequency 54 BSC6900 ADD GCELLFREQ(Optional)ADD GCELLMAGRP(Optional) Frequency 54 GBFD-110101Frequency Band Interval Type 0~1023 0~1023 None None None Cell None Read & Write Services are disrupted when the BCCH frequency in a cell is changed. Cell Less than 5 minutes If the BCCH frequency of a cell is changed, the BSC forcibly hands over the calls in this cell to another cell and then resets this cell.
FREQ55 Frequency 55 BSC6900 ADD GCELLFREQ(Optional)ADD GCELLMAGRP(Optional) Frequency 55 GBFD-110101Frequency Band Interval Type 0~1023 0~1023 None None None Cell None Read & Write Services are disrupted when the BCCH frequency in a cell is changed. Cell Less than 5 minutes If the BCCH frequency of a cell is changed, the BSC forcibly hands over the calls in this cell to another cell and then resets this cell.
FREQ56 Frequency 56 BSC6900 ADD GCELLFREQ(Optional)ADD GCELLMAGRP(Optional) Frequency 56 GBFD-110101Frequency Band Interval Type 0~1023 0~1023 None None None Cell None Read & Write Services are disrupted when the BCCH frequency in a cell is changed. Cell Less than 5 minutes If the BCCH frequency of a cell is changed, the BSC forcibly hands over the calls in this cell to another cell and then resets this cell.
FREQ57 Frequency 57 BSC6900 ADD GCELLFREQ(Optional)ADD GCELLMAGRP(Optional) Frequency 57 GBFD-110101Frequency Band Interval Type 0~1023 0~1023 None None None Cell None Read & Write Services are disrupted when the BCCH frequency in a cell is changed. Cell Less than 5 minutes If the BCCH frequency of a cell is changed, the BSC forcibly hands over the calls in this cell to another cell and then resets this cell.
FREQ58 Frequency 58 BSC6900 ADD GCELLFREQ(Optional)ADD GCELLMAGRP(Optional) Frequency 58 GBFD-110101Frequency Band Interval Type 0~1023 0~1023 None None None Cell None Read & Write Services are disrupted when the BCCH frequency in a cell is changed. Cell Less than 5 minutes If the BCCH frequency of a cell is changed, the BSC forcibly hands over the calls in this cell to another cell and then resets this cell.
FREQ59 Frequency 59 BSC6900 ADD GCELLFREQ(Optional)ADD GCELLMAGRP(Optional) Frequency 59 GBFD-110101Frequency Band Interval Type 0~1023 0~1023 None None None Cell None Read & Write Services are disrupted when the BCCH frequency in a cell is changed. Cell Less than 5 minutes If the BCCH frequency of a cell is changed, the BSC forcibly hands over the calls in this cell to another cell and then resets this cell.
FREQ6 Frequency 6 BSC6900 ADD GCELLFREQ(Optional)ADD GCELLMAGRP(Optional) Frequency 6 GBFD-110101Frequency Band Interval Type 0~1023 0~1023 None None None Cell None Read & Write Services are disrupted when the BCCH frequency in a cell is changed. Cell Less than 5 minutes If the BCCH frequency of a cell is changed, the BSC forcibly hands over the calls in this cell to another cell and then resets this cell.
FREQ60 Frequency 60 BSC6900 ADD GCELLFREQ(Optional)ADD GCELLMAGRP(Optional) Frequency 60 GBFD-110101Frequency Band Interval Type 0~1023 0~1023 None None None Cell None Read & Write Services are disrupted when the BCCH frequency in a cell is changed. Cell Less than 5 minutes If the BCCH frequency of a cell is changed, the BSC forcibly hands over the calls in this cell to another cell and then resets this cell.
FREQ61 Frequency 61 BSC6900 ADD GCELLFREQ(Optional)ADD GCELLMAGRP(Optional) Frequency 61 GBFD-110101Frequency Band Interval Type 0~1023 0~1023 None None None Cell None Read & Write Services are disrupted when the BCCH frequency in a cell is changed. Cell Less than 5 minutes If the BCCH frequency of a cell is changed, the BSC forcibly hands over the calls in this cell to another cell and then resets this cell.
FREQ62 Frequency 62 BSC6900 ADD GCELLFREQ(Optional)ADD GCELLMAGRP(Optional) Frequency 62 GBFD-110101Frequency Band Interval Type 0~1023 0~1023 None None None Cell None Read & Write Services are disrupted when the BCCH frequency in a cell is changed. Cell Less than 5 minutes If the BCCH frequency of a cell is changed, the BSC forcibly hands over the calls in this cell to another cell and then resets this cell.
FREQ63 Frequency 63 BSC6900 ADD GCELLFREQ(Optional)ADD GCELLMAGRP(Optional) Frequency 63 GBFD-110101Frequency Band Interval Type 0~1023 0~1023 None None None Cell None Read & Write Services are disrupted when the BCCH frequency in a cell is changed. Cell Less than 5 minutes If the BCCH frequency of a cell is changed, the BSC forcibly hands over the calls in this cell to another cell and then resets this cell.
FREQ64 Frequency 64 BSC6900 ADD GCELLFREQ(Optional)ADD GCELLMAGRP(Optional) Frequency 64 GBFD-110101Frequency Band Interval Type 0~1023 0~1023 None None None Cell None Read & Write Services are disrupted when the BCCH frequency in a cell is changed. Cell Less than 5 minutes If the BCCH frequency of a cell is changed, the BSC forcibly hands over the calls in this cell to another cell and then resets this cell.
FREQ7 Frequency 7 BSC6900 ADD GCELLFREQ(Optional)ADD GCELLMAGRP(Optional) Frequency 7 GBFD-110101Frequency Band Interval Type 0~1023 0~1023 None None None Cell None Read & Write Services are disrupted when the BCCH frequency in a cell is changed. Cell Less than 5 minutes If the BCCH frequency of a cell is changed, the BSC forcibly hands over the calls in this cell to another cell and then resets this cell.
FREQ8 Frequency 8 BSC6900 ADD GCELLFREQ(Optional)ADD GCELLMAGRP(Optional) Frequency 8 GBFD-110101Frequency Band Interval Type 0~1023 0~1023 None None None Cell None Read & Write Services are disrupted when the BCCH frequency in a cell is changed. Cell Less than 5 minutes If the BCCH frequency of a cell is changed, the BSC forcibly hands over the calls in this cell to another cell and then resets this cell.
FREQ9 Frequency 9 BSC6900 ADD GCELLFREQ(Optional)ADD GCELLMAGRP(Optional) Frequency 9 GBFD-110101Frequency Band Interval Type 0~1023 0~1023 None None None Cell None Read & Write Services are disrupted when the BCCH frequency in a cell is changed. Cell Less than 5 minutes If the BCCH frequency of a cell is changed, the BSC forcibly hands over the calls in this cell to another cell and then resets this cell.
FREQADJ Frequency Adjust Switch BSC6900 SET GCELLOTHEXT(Optional) Whether to enable the automatic frequency correction algorithm. This parameter is used for the fast-moving handover algorithm. If the parameter is set to YES, the BTS calculates the speed at which an MS leaves or approaches it, and sends the BSC the calculated speed in an uplink measurement report. GBFD-510101AFC(Automatic Frequency Correction) Enumeration Type NO(No), YES(Yes)NO, YES None None NO Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FREQADJVALUE Frequency Adjust Value BSC6900 SET GCELLOTHEXT(Optional) Frequency correction parameter. Used for the fast-moving handover algorithm, the value of this parameter must be translated into a binary number. The value consists of 16 bit. The most significant bit indicates whether the parameter is valid. Bits 14 to 8 indicate the level threshold. Bits 7 to 0 indicate the threshold of the bit error ratio (BER).The BSC sends this parameter to the BTS, which adjusts the frequency of an MS according to the value of this parameter. GBFD-510101AFC(Automatic Frequency Correction) Interval Type 0~65535 0~65535 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FREQBAND Frequency Band Attribute BSC6900 ADD BTSANTFEEDERBRD(Optional) Frequency band attribute of the board MRFD-210301Configuration Management Enumeration Type PGSM900(PGSM900), EGSML25(EGSM<L25>), EGSM35M(EGSM<35M>), RGSML25(RGSM<L25>), GSM900_RGSM39M(GSM900_RGSM<39M>), DCS1800(DCS1800), PCS1900(PCS1900), GSM850(GSM850), EGSM24M(EGSM<24M>), DCS1800_L(DCS1800<L50M>), DCS1800_H(DCS1800<H50M>) PGSM900, EGSML25, EGSM35M, RGSML25, GSM900_RGSM39M, DCS1800, PCS1900, GSM850, EGSM24M, DCS1800_L, DCS1800_H None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FREQLOADSHARETRAFFTHRSH GSM900 Band Traffic Load Share Threshold BSC6900 SET GCELLCHMGAD(Optional) Threshold for load sharing in the 900 MHz frequency band. Assume that an MS supports multiple sub-bands in the 900 MHz frequency band. If the cell load is equal to or less than this threshold, the BSC does not consider the priority levels of the P-GSM, E-GSM, and R-GSM sub-bands during channel assignment. If the cell load is greater than this threshold, the BSC assigns channels according to the priority levels of the P-GSM, E-GSM, and R-GSM sub-bands. That is, if the MS supports the P-GSM, E-GSM, and R-GSM sub-bands and the cell is configured with the TRXs in the P-GSM, E-GSM, and R-GSM sub-bands, the BSC assigns the channels in the TRXs of the R-GSM sub-band preferentially. GBFD-111005Enhanced Channel Assignment Algorithm Interval Type 0~100 0~100 per cent None 25 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FREQLST Freq band list BSC6900 SET GCELLFREQSCAN(Optional) List of frequency bands GBFD-112401Cell Frequency Scan Interval Type 0~1023 0~1023 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FREQREUSEMODE Frequency Reuse Mode BSC6900 SET GTRXDEV(Optional) Frequency multiplexing mode in the TRX. To enable a loose frequency multiplexing mode such as 4x3 multiplexing, set this parameter to LOOSE. To enable a tight frequency multiplexing mode such as 1x3 or 1x1, set this parameter to TIGHT. MRFD-210301Configuration Management Enumeration Type LOOSE(Loose), TIGHT(Tight) LOOSE, TIGHT None None None TRX None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FREQS Frequency List BSC6900 STR NCS(Mandatory) List of the frequencies to be measured. This parameter is represented as a character string where the IDs of the TRXs to be measured are separated by &, such as 1&124&956. GBFD-5109012G/3G Neighboring Cell Automatic Optimization String Type None 1~800 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FREQSCANRLSTTYPE Frequency Scan Result Type BSC6900 SET GCELLSOFT(Optional) Type of a scanning result in the period from the start of a frequency scanning task to the reporting of the scanning result.Frequency scanning refers to the scanning of an uplink receive level of a cell frequency. The scanning result reflects the strength of frequency signals received by the cell. GBFD-112401Cell Frequency Scan Enumeration Type MainDiversity(MainDiversity), MaximumMeanValue(MaximumMeanValue) MainDiversity, MaximumMeanValue None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter is valid in only the cells in the coverage area of the BTS3X.
FRINGEHOEN Fringe HO Allowed BSC6900 SET GCELLHOBASIC(Optional) Whether to enable the edge handover algorithm. When an MS makes a call at the edge of a cell, the call may drop if the received signal level is too low. To avoid such a call drop, the edge handover algorithm is involved. When the uplink signal level of the serving cell is less than "Edge HO UL RX_LEV Threshold" or the downlink signal level of the serving cell is less than "Edge HO DL RX_LEV Threshold", the edge handover is triggered. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Enumeration Type NO(No), YES(Yes)NO, YES None None YES Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FRMFLAG Frame Log Flag BSC6900 SET LOGCFG(Optional) Frame Log FlagMRFD-210304Faulty Management Enumeration Type DISABLE~0ENABLE DISABLE~0ENABLE~1None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FRULDTX FR Uplink DTX BSC6900 SET GCELLBASICPARA(Optional) Whether the uplink (DTX) function is enabled for FR calls. For details, see GSM Rec. 05.08. GBFD-114803Discontinuous Transmission (DTX) Uplink Enumeration Type May_Use(May Use), Shall_Use(Shall Use), Shall_NOT_Use(Shall not Use) May_Use, Shall_Use, Shall_NOT_Use None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FSN Slot No. of father BTS BSC6900 ADD BTSAUTOPLAN(Mandatory) Slot No. of the father BTS GBFD-510701Compact BTS Automatic Configuration and Planning Interval Type 0~23 0~23 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FSN Slot No. of father BTS BSC6900 ADD BTSCONNECT(Optional) Slot No. for the port of the father BTS GBFD-111202O&M of BTS Interval Type 0~23 0~23 None None None BTS None Read & Write Y BTS Less than 5 minutes This parameter can be modified only when the BTS is deactivated.
FSRN Subrack No. of father BTS BSC6900 ADD BTSAUTOPLAN(Mandatory) Subrack No. of the father BTS GBFD-510701Compact BTS Automatic Configuration and Planning Interval Type 0~255 0~255 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FSRN Subrack No. of father BTS BSC6900 ADD BTSCONNECT(Optional) Subrack No. for the port of the father BTS GBFD-111202O&M of BTS Interval Type 0~254 0~254 None None None BTS None Read & Write Y BTS Less than 5 minutes This parameter can be modified only when the BTS is deactivated.
FT File Type BSC6900 EXP LOG(Optional) Type of the file used for saving exported logs GBFD-111203MRFD-210305 O&M of BSCSecurity Management Enumeration Type TXT(PlainTxt), CSV(CSV Type) TXT, CSV None TXT TXT RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FTI Factor table index BSC6900 ADD ADJMAP(Mandatory) Activation factor table index None None Interval Type 0~33 0~33 None None None Adjacent node The factor table index is configured by setting the value of "FTI" in "ADD FACTORTABLE". Read & Write N (No impact on the UE in idle mode) Not involved Not involved The FACTORTABLE must be configured.
FTI Factor table index BSC6900 ADD TRMFACTOR(Mandatory) Activation factor table index None None Interval Type 1~33 1~33 None None None BSC6900None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
FTI Factor table index BSC6900 SET BTSABISPRIMAP(Mandatory) Activation factor table index None None Interval Type 0~33 0~33 None None None BSC6900None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
FULLTOHALFHOATCBOFFSET F-H ATCB Offset Overlay BSC6900 SET GCELLHOBASIC(Optional) ATCB difference between the overlaid and underlaid subcells GBFD-510501HUAWEI II Handover Interval Type 0~255 0~255 dB None 20 Cell This parameter is valid only when "HOCTRLSWITCH" is set to HOALGORITHM2. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FULLTOHALFHODURATION F-H Ho Duration BSC6900 SET GCELLHOBASIC(Optional) Duration of the handover from full rate to half rate. If the cell load is greater than the preset threshold, the calls that meet the conditions for the handover from full rate to half rate are handed over from full rate to half rate in this duration. GBFD-510501HUAWEI II Handover Interval Type 0~600 0~600 s None 5 Cell This parameter is valid only when "HOCTRLSWITCH" is set to HOALGORITHM2. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FULLTOHALFHOLASTTIME F-H Ho Last Time BSC6900 SET GCELLHOBASIC(Optional) According to the P/N rule, if the conditions for the handover from full rate to half rate are met for P seconds within N seconds, the handover is triggered.This parameter specifies the number P. GBFD-510501HUAWEI II Handover Interval Type 1~16 1~16 s None 2 Cell This parameter is valid only when "HOCTRLSWITCH" is set to HOALGORITHM2. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FULLTOHALFHOPATHOFFSET F-H Pathloss Offset Overlay BSC6900 SET GCELLHOBASIC(Optional) Path loss difference between the overlaid and underlaid subcells GBFD-510501HUAWEI II Handover Interval Type 0~255 0~255 dB None 10 Cell This parameter is valid only when "HOCTRLSWITCH" is set to HOALGORITHM2. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FULLTOHALFHOPERIOD F-H Ho Period BSC6900 SET GCELLHOBASIC(Optional) Period of the handover from full rate to half rate. If the cell load is greater than the preset threshold, the calls that meet the conditions for the handover from full rate to half rate are handed over in "H-F Ho Duration". This parameter specifies the bandwidth to be handed over at each hierarchy level. GBFD-510501HUAWEI II Handover Interval Type 0~600 0~600 s None 1 Cell This parameter is valid only when "HOCTRLSWITCH" is set to HOALGORITHM2. The following condition must be met: "FULLTOHALFHODURATION" >= "FULLTOHALFHOPERIOD". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FULLTOHALFHOSTATTIME F-H Ho Stat. Time BSC6900 SET GCELLHOBASIC(Optional) According to the P/N rule, if the conditions for the handover from full rate to half rate are met for P seconds within N seconds, the handover is triggered.This parameter specifies the number N. GBFD-510501HUAWEI II Handover Interval Type 1~16 1~16 s None 3 Cell This parameter is valid only when "HOCTRLSWITCH" is set to HOALGORITHM2. The following condition must be met: "FULLTOHALFHOSTATTIME" >= "FULLTOHALFHOLASTTIME". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FWDCONGBW Forward congestion remain bandwidth BSC6900 ADD TRMLOADTH(Optional) Forward congestion remain bandwidth None None Interval Type 0~200000 0~200000 kbit/s 0 0 BSC6900None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
FWDCONGCLRBW Forward congestion clear bandwidth BSC6900 ADD TRMLOADTH(Optional) Forward congestion clear bandwidth None None Interval Type 0~200000 0~200000 kbit/s 0 0 BSC6900None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
FWDCONGCLRTH Forward congestion clear remain ratio BSC6900 ADD TRMLOADTH(Optional) Forward congestion clear remain ratio None None Interval Type 0~100 0~100 per cent 20 20 BSC6900None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
FWDCONGTH Forward congestion remain ratio BSC6900 ADD TRMLOADTH(Optional) Forward congestion remain ratio None None Interval Type 0~100 0~100 per cent 15 15 BSC6900None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
FWDOVLDCLRRSVBW Forward overload congestion clear remain bandwidth BSC6900 ADD TRMLOADTH(Optional) Forward overload congestion clear remain bandwidth None None Interval Type 0~200000 0~200000 kbit/s 0 0 BSC6900None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
FWDOVLDCLRTH Forward overload congestion clear remain ratio BSC6900 ADD TRMLOADTH(Optional) Forward overload congestion clear remain ratio None None Interval Type 0~100 0~100 per cent 1 1 BSC6900None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
FWDOVLDRSVBW Forward overload congestion reserved bandwidth BSC6900 ADD TRMLOADTH(Optional) Forward overload congestion reserved bandwidth None None Interval Type 0~200000 0~200000 kbit/s 0 0 BSC6900None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
FWDOVLDTH Forward overload congestion remain ratio BSC6900 ADD TRMLOADTH(Optional) Forward overload congestion remain ratio None None Interval Type 0~100 0~100 per cent 0 0 BSC6900None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
FWDRESVHOTH Forward handover reserved ratio BSC6900 ADD TRMLOADTH(Optional) Forward handover reserved ratio None None Interval Type 0~100 0~100 per cent 5 5 BSC6900None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
FWDRSVHOBW Forward handover reserved bandwidth BSC6900 ADD TRMLOADTH(Optional) Forward handover reserved bandwidth None None Interval Type 0~200000 0~200000 kbit/s 0 0 BSC6900None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
FWFLAG Flow Log Flag BSC6900 SET LOGCFG(Optional) Flow Log Flag MRFD-210304Faulty Management Enumeration Type DISABLE~0ENABLE DISABLE~0ENABLE~1None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
FWMAXNUM The Upper Limit Of Process Log Can Start BSC6900 SET LOGCFG(Optional) The Upper Limit Of Process Log Can Start MRFD-210304Faulty Management Interval Type 10~1000 {10~1000} None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
G2G3GLdBlcDeltaThrd CS 2G 3G Load Balance Delta Threshold BSC6900 SET OTHSOFTPARA(Optional) If the load balance between a 2G cell and a 3G cell is greater than the threshold, load balance is triggered. MRFD-211402MBSC Load Balancing Interval Type 0~200 {-100~100} per cent None 110 BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
G2GLoadAdjustCoeff 2G Load Adjustment Coefficient BSC6900 SET GCELLHOINTERRATLDB(Optional) Coefficient used to modulate the load level of a 2G system so that the load level of the 2G system can be compared with that of a 3G system. MRFD-211402MBSC Load Balancing Interval Type 0~100 {0~100} None None None BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
G711_Mode G711 Mode BSC6900 SET TCPARA(Optional) G711 Mode. A/U law configuration, 0-A law (default), 1-U law GBFD-118602A over IP Enumeration Type A0, U1 A0, U1 None None None Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
GAMMA GAMMA BSC6900 SET GCELLPSPWPARA(Optional) Expected signal receiving strength on the BTS side when GPRS dynamic power control is implemented. GBFD-119115Power Control Interval Type 0~31 0~31 None None 12 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
GATHET Offset Collection End Time BSC6900 ADD AISSCFG(Optional) End time for collecting the offset information. GBFD-118201Soft-Synchronized Network Compound Type hour, min hour{0~23}min{0~59} None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None.
GATHLOD Load Threshold Of Offset Collection BSC6900 ADD AISSCFG(Optional) Cell load threshold for collecting the offset information. If the load threshold is exceeded, the offset information is not collected. GBFD-118201Soft-Synchronized Network Interval Type 0~100 0~100 None 40 None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None.
GATHON Offset Information Collection Switch BSC6900 ADD AISSCFG(Mandatory) Whether to collect the offset information. GBFD-118201Soft-Synchronized Network Enumeration Type OFF(OFF), ON(ON) OFF, ON None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None.
GATHST Offset Collection Start Time BSC6900 ADD AISSCFG(Optional) Start time for collecting the offset information. GBFD-118201Soft-Synchronized Network Compound Type hour, min hour{0~23}min{0~59} None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None.
GBRQOS Support GBR QoS BSC6900 SET GCELLPSOTHERPARA(Optional) Obtains the QoS parameter from the Aggregate BSS QoS Profile (ABQP) of packet flow context (PFC) when the MS and the network support the PFC; obtains the QoS parameter from the uplink request originated by the MS or the DL UNITDATA of the SGSN. Gbr: guaranteed bit rate. GBFD-119901Streaming QoS(GBR) Enumeration Type NO(Not Support), YES(Support) NO, YES None None NO Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
GCChk Group Call Check BSC6900 SET BSCBASIC(Optional) Whether to enable the function of group call check. If the function is enabled, the BSC regularly performs a check on the group call resources of the BTS. GBFD-510301GBFD-510302 Public Voice Group Call ServicePublic Voice Broadcast Service Enumeration Type OFF(Off), ON(On) OFF, ON None None ON BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
GCSCHNASSULCHNEN VGCS Channel Assign in Channel Enable BSC6900 SET GCELLGSMR(Optional) Whether the assignment of channels in overlaid subcells is enabled for the VGCS service in the case of underlaid subcell congestion. Generally, only the channels in underlaid subcells can be assigned to the VGCS service. GBFD-510301GBFD-510302 Public Voice Group Call ServicePublic Voice Broadcast Service Enumeration Type NO(No), YES(Yes)NO, YES None None YES Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
GCSIMPREEMPTIONEN VGCS IM Preemption Enable BSC6900 SET GCELLGSMR(Optional) Whether direct preemption of the channels of other services is enabled for the VGCS service. If the value of this parameter is NO, a handover is performed for the call whose channel is preempted. If the value is YES, calls on the preempted channel are directly released. GBFD-510307Group Call EMLPP Enumeration Type NO(No), YES(Yes)NO, YES None None YES Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
GENCCHDL UMTS general common channel service downlink factor BSC6900 ADD TRMFACTOR(Optional) WCDMA AMR general common channel service downlink factor None None Interval Type 0~100 0~100 per cent 70 70 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node that is configured with the factor table. After the successful modification, the parameter takes effect in the following two cases:1. New access subscriber. 2. Bandwidth modification of the existing subscriber
GENCCHUL UMTS general common channel service uplink factor BSC6900 ADD TRMFACTOR(Optional) WCDMA general common channel service uplink factor None None Interval Type 0~100 0~100 per cent 70 70 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node that is configured with the factor table. After the successful modification, the parameter takes effect in the following two cases:1. New access subscriber. 2. Bandwidth modification of the existing subscriber
GLOBALROUTESW Global route management switch BSC6900 SET GLOBALROUTESW(Mandatory) Global routing management switch. If this switch is turned on, the IP addresses in the controlled range cannot be in the same network segment. None None Enumeration Type OFF(Disable the golbal route management), ON(Enable the golbal route management) OFF, ON None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter determines whether to load data from the OMU or the FLASH when the BSC or the board is restarted. The equipment is affected.
GMSKDELAY Diversity Transmitter GMSK Delay BSC6900 SET GCELLBASICPARA(Optional) Delay of the transmit diversity. Generally, the parameter is set to 2 bit (7.4 us), applicable to general fading environments. A transmit diversity can generally obtain the gain of 3 dB to 5 dB. Because the fading conditions vary with the environment where an MS lies, however, MSs in a fixed time delay obtain different gains, which may have negative effects on some codes of the EDGE service. Therefore, the time delay of transmit diversity must be configurable and can be separately set for GMSK and 8PSK. GBFD-114101GPRS Interval Type 4~32 0.5~4, step: 1/8 bit None 16 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The value of this parameter is valid only for the BTSs of the double-transceiver series and the distributed BTSs.
GPRS GPRS BSC6900 SET GCELLGPRS(Mandatory) Whether the current cell supports GPRS. GBFD-114101GPRS Enumeration Type NO(Not Support), SupportAsInnPcu(Support As Inner Pcu), SupportAsExtPcu(Support As Outer Pcu) NO, SupportAsInnPcu, SupportAsExtPcu None None None Cell None Read & Write Y Cell If this parameter is set to "NO", cell does not support GPRS. None
GPRS Support GPRS BSC6900 ADD GCELLQUICKSETUP(Optional) Whether the currently cell supports the GPRS GBFD-114101GPRS Enumeration Type NO, SupportAsInnPcu, SupportAsExtPcu NO, SupportAsInnPcu, SupportAsExtPcu None NO NO Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
GPRSCELLRESELECTHYESTERESIS GPRS Cell Reselect Hysteresis BSC6900 SET GCELLRESELECTPARA(Optional) Hysteresis value of the cell in the same routing area. When the MS in the ready state reselects a cell, if the original cell and the target cell are in the same routing area, the C2 values of the two cells at the border of the cell are quite different due to radio channel fading. As a result, the MS frequently reselects cells. Frequent cell reselection can lead to increase of signalling traffic, inefficient use of radio resources, decrease of MS data transmission rate, and thus reducing the network service quality. The cell reselection hysteresis parameter is introduced. The signal level of the adjacent cell in the same area must be greater than that of the local cell. The difference of the signal level must be greater than the value of the cell reselection hysteresis parameter. Otherwise, the MS cannot reselect a cell. The greater the GPRS cell reselection hysteresis value, the harder to start cell reselection. GBFD-114101GPRS Enumeration Type 0dB(0dB), 2dB(2dB), 4dB(4dB), 6dB(6dB), 8dB(8dB), 10dB(10dB), 12dB(12dB), 14dB(14dB) 0dB, 2dB, 4dB, 6dB, 8dB, 10dB, 12dB, 14dB dB None 2dB Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
GPRSCHPRI PDCH Channel Priority Type BSC6900 SET GTRXCHAN(Optional) EGPRS priority type of the channelIf this parameter is set to GPRS, the EDGE MSs cannot use this channel.If this parameter is set to EGPRSNORCH, the GPRS and EDGE MSs can use this channel at the same priority.If this parameter is set to EGPRSPRICH, the EDGE MSs have the priority to use this channel.If this parameter is set to EGPRSSPECH, only the EDGE MSs can use this channel.If this parameter is set to NONGPRS, this parameter becomes invalid. GBFD-114201EGPRS Enumeration Type GPRS(GPRS Channel), EGPRSNORCH(EGPRS Normal Channel), EGPRSPRICH(EGPRS Priority Channel), EGPRSSPECH(EGPRS Special Channe), NONGPRS(Non-GPRS Channel) GPRS, EGPRSNORCH, EGPRSPRICH, EGPRSSPECH, NONGPRS None None None Physical channel None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
GPRSHCSTHR Threshold of HCS Signal Strength BSC6900 SET GCELLSERVPARA(Optional) Threshold of hierarchical cell structure (HCS) signal strength. The MS calculates the C31 according to the signal strength and its threshold and selects the adjacent cell during cell reselection. GBFD-114101GPRS Enumeration Type DB110(-110dB), DB108(-108dB), DB106(-106dB), DB104(-104dB), DB102(-102dB), DB100(-100dB), DB98(-98dB), DB96(-96dB), DB94(-94dB), DB92(-92dB), DB90(-90dB), DB88(-88dB), DB86(-86dB), DB84(-84dB), DB82(-82dB), DB80(-80dB), DB78(-78dB), DB76(-76dB), DB74(-74dB), DB72(-72dB), DB70(-70dB), DB68(-68dB), DB66(-66dB), DB64(-64dB), DB62(-62dB), DB60(-60dB), DB58(-58dB), DB56(-56dB), DB54(-54dB), DB52(-52dB), DB50(-50dB), DB48(-48dB), nouse(no use) DB110, DB108, DB106, DB104, DB102, DB100, DB98, DB96, DB94, DB92, DB90, DB88, DB86, DB84, DB82, DB80, DB78, DB76, DB74, DB72, DB70, DB68, DB66, DB64, DB62, DB60, DB58, DB56, DB54, DB52, DB50, DB48, no use dB None DB110 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
GPRSPENALTYTIME GPRS Penalty Time BSC6900 SET GCELLNCRESELECTPARA(Optional) Timer used when the MS calculates the C2 (used to evaluate the channel quality during cell reselection). The time information is transmitted in the system message of each cell. GBFD-114101GPRS Enumeration Type 10sec(10sec), 20sec(20sec), 30sec(30sec), 40sec(40sec), 50sec(50sec), 60sec(60sec), 70sec(70sec), 80sec(80sec), 90sec(90sec), 100sec(100sec), 110sec(110sec), 120sec(120sec), 130sec(130sec), 140sec(140sec), 150sec(150sec), 160sec(160sec), 170sec(170sec), 180sec(180sec), 190sec(190sec), 200sec(200sec), 210sec(210sec), 220sec(220sec), 230sec(230sec), 240sec(240sec), 250sec(250sec), 260sec(260sec), 270sec(270sec), 280sec(280sec), 290sec(290sec), 300sec(300sec), 310sec(310sec), 320sec(320sec), nouse(no use) 10sec, 20sec, 30sec, 40sec, 50sec, 60sec, 70sec, 80sec, 90sec, 100sec, 110sec, 120sec, 130sec, 140sec, 150sec, 160sec, 170sec, 180sec, 190sec, 200sec, 210sec, 220sec, 230sec, 240sec, 250sec, 260sec, 270sec, 280sec, 290sec, 300sec, 310sec, 320sec, no use s None 10sec Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
GPRSRXQUALLIMIT GPRS Quality Threshold BSC6900 SET GCELLNC2PARA(Optional) Used for the GPRS transmission quality statistics. When the transmission quality threshold is exceeded, the transmission quality is regarded deteriorated. GBFD-116201Network-Controlled Cell Reselection (NC2) Interval Type 0~7 0~7 None None 5 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
GPRSTEMPOFFSET GPRS Temporary Offset BSC6900 SET GCELLNCRESELECTPARA(Optional) This parameter is used to prevent repeated cell reselection of a fast moving MS. The MS does not select this cell when the duration of maintaining the BCCH signal channel strength does not reach the penalty time. GBFD-114101GPRS Enumeration Type 0db(0db), 10db(10db), 20db(20db), 30db(30db), 40db(40db), 50db(50db), 60db(60db), infinity(infinity), nouse(no use) 0db, 10db, 20db, 30db, 40db, 50db, 60db, infinity, no use dB None 10db Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
GPSORGLONASS GPS or Glonass BSC6900 SET BTSDGPSBP(Optional)SET BTSUSCUBP(Optional) Synchronization clock adopted when two satellite cards are used together GBFD-510401BTS GPS Synchronization Enumeration Type GPS(GPS), GLONASS(Glonass), GPSGlonass(GPSGlonass) GPS, GLONASS, GPSGlonass None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
GRADEACCALLOW Grade Access Allow BSC6900 SET GCELLCHMGBASIC(Optional) Whether to allow hierarchical access and to reserve resources for high-priority MSs GBFD-116001Resource Reservation Enumeration Type NO(No), YES(Yes)NO, YES None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
GROUPCALLNUM1 Group Call Num 1 BSC6900 SET BTSCHNFALLBACK(Mandatory) Number of the VGCS call that the BTS originates in the timeslot in the TRX in fallback mode. This parameter is represented in decimal, such as 10000569. If this parameter is set to 100000000, the channel is not configured with any fixed group call. GBFD-510309Group Call Reliability Enhancing Interval Type 0~100000000 0~100000000 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter is supported only by the following types of BTSs: BTS3012, BTS3006C, BTS3012AE, BTS3012 II, and BTS3002E.
5/5/2014
Confidential Information of Huawei.
No Spreading without Permission
Page9of42
226347869.xls.ms_office Security Level:
GROUPCALLNUM2 Group Call Num 2 BSC6900 SET BTSCHNFALLBACK(Mandatory) Number of the VGCS call that the BTS originates in the timeslot in the TRX in fallback mode. This parameter is represented in decimal, such as 10000569. If this parameter is set to 100000000, the channel is not configured with any fixed group call. GBFD-510309Group Call Reliability Enhancing Interval Type 0~100000000 0~100000000 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter is supported only by the following types of BTSs: BTS3012, BTS3006C, BTS3012AE, BTS3012 II, and BTS3002E.
GROUPINDEX BSC Node Redundancy Group Index BSC6900 SET GBSCREDGRP(Mandatory) Index of the BSC Node Redundancy Group. GBFD-113725BSC Node Redundancy Interval Type 0~65534 0~65534 None None None BSC6900None Read & Write Y BTS Less than 10 minutes None
GROUPNAME BSC Node Redundancy Group Name BSC6900 SET GBSCREDGRP(Optional) Name of the BSC Node Redundancy Group. GBFD-113725BSC Node Redundancy String Type None 1~20 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
GROUPRELTSNUM Group release TS number BSC6900 SET BTSFLEXABISPARA(Optional) Maximum number of secondary links that are released in batches when the Abis resource preemption occurs on the Abis interface GBFD-117301Flex Abis Interval Type 0~512 0~512 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
GRPID Transport Resource Group No. BSC6900 ADD RSCGRP(Mandatory)SET BTSIP(Mandatory) Transport resource group No. None None Interval Type 0~2047 0~2047 None None None Transmission resource group None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
GRPT Transport Resource Group Type BSC6900 ADD RSCGRP(Mandatory) Transport resource group type None None Enumeration Type ATM(ATM), IP(IP) ATM, IP None None None Transmission resource group None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
GS Geography Scope BSC6900 SET GCELLSBC(Optional)ADD GSMSCB(Mandatory) Geographical coverage of a simple cell broadcast message. You can run "DSP GSMSCB" to query and obtain the information.This parameter, "Code", and "Update" uniquely specify a cell broadcast message. GBFD-113602Simplified Cell Broadcast Enumeration Type LAC_CI(CELL IMME), PLMN(ALL), LAC(LAC), CI(CELL) LAC_CI, PLMN, LAC, CI None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
GSMBWRATE GSM ratio BSC6900 ADD TRMLOADTH(Optional) Common transport GSM bandwidth ratio. MRFD-2115032G/3G Co-Transmission Resources Management on MBSC Interval Type 0~100 0~100 per cent 80 80 Transmission resource group None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
GSMCSBWRATE CS ratio BSC6900 ADD TRMLOADTH(Optional) GSM CS bandwidth ratio None None Interval Type 0~100 0~100 per cent 80 80 Transmission resource group None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
GSMCSUSERHIGHPRILEV GSM CS high level standard BSC6900 SET BSCBASIC(Optional) Standard priority for GSM CS high-priprity MSs GBFD-118605IP QOS Interval Type 1~15 1~15 None None 10 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
GSMFREQCNUM Serving Band Reporting BSC6900 SET GCELLCCUTRANSYS(Optional) Number of neighboring cells that meet the following conditions: If "MBR" is indicated in a system message, the MS reports the number of neighboring cells at each frequency band. If the MS reports the number of neighboring cells at the same frequency band of the serving cell, it can report a maximum of the value of this parameter.These neighboring cells must meet the following requirements:1. The receive levels of the neighboring cells must be higher than "900 Reporting Threshold" or "1800 Reporting Threshold".2. The BSIC of a neighboring cell must be valid.3. The signals of the neighboring cells must be the strongest among all the neighboring cells at the same frequency band. GBFD-114401Multi-band Sharing One BSC Interval Type 0~3 0~3 None None None Cell This parameter is valid when "MEASURETYPE" is set to EnhMeasReport. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
GSMTOTDALLOWED GSM-to-TD Cell Reselection Allowed BSC6900 SET GCELLPSOTHERPARA(Optional) Whether to support the cell reselection from the GSM network to the TD network in the packet transmission mode. GBFD-114302GSM/TD-SCDMA Interoperability Enumeration Type UNSUPPORT(Not Support), SUPPORT(Support) UNSUPPORT, SUPPORT None None SUPPORT Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
GUARDTYPE ICMP type which will be guarded BSC6900 ADD ICMPGUARD(Mandatory) Packet type against the ICMP attack None None Bit Field Type ECHOREPLY, UNREACH, SOURCEQUENCH, REDIRECT, ECHO, ROUTERADVERT, ROUTERSOLICIT, TIMXCEED, PARAMPROB, TSTAMP, TSTAMPREPLY, IREQ, IREQREPLY, MASKREQ, MASKREPLY ECHOREPLY, UNREACH, SOURCEQUENCH, REDIRECT, ECHO, ROUTERADVERT, ROUTERSOLICIT, TIMXCEED, PARAMPROB, TSTAMP, TSTAMPREPLY, IREQ, IREQREPLY, MASKREQ, MASKREPLY None None None Ethernet port None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
GWIP BTS SeGW IP Address BSC6900 ADD BTSAUTOPLAN(Optional) When the BTS is accessed from the public network, the BTS security network IP address must be configured. GBFD-118601Abis over IP IP Address Type None 0.0.0.0~255.255.255.255 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
GWIP BTS SeGW IP Address BSC6900 SET BTSIP(Optional) IP address of the BTS security gateway. This parameter needs to be configured when the BTS connects to the BSC through the public network. GBFD-118601Abis over IP IP Address Type None 0.0.0.0~255.255.255.255 None None None BTS None Read & Write Y BTS Less than 5 minutes None
HalfRateDataSupport Support Half Rata Data Service BSC6900 SET OTHSOFTPARA(Optional) Whether to support CS half rate data services GBFD-113401Half Rate Speech Enumeration Type NO(No), YES(Yes)NO, YES None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
HALFTOFULLATCBOFFSET H-F ATCB Offset Overlay BSC6900 SET GCELLHOBASIC(Optional) ATCB difference between the overlaid and underlaid subcells GBFD-510501HUAWEI II Handover Interval Type 0~255 0~255 dB None 20 Cell This parameter is valid only when "HOCTRLSWITCH" is set to HOALGORITHM2. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
HALFTOFULLHODURATION H-F Ho Duration BSC6900 SET GCELLHOBASIC(Optional) Duration of the handover from half rate to full rate. If the cell load is less than the preset threshold, the calls that meet the conditions for the handover from half rate to full rate are handed over from half rate to full rate in this duration. GBFD-510501HUAWEI II Handover Interval Type 0~600 0~600 s None 5 Cell This parameter is valid only when "HOCTRLSWITCH" is set to HOALGORITHM2. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
HALFTOFULLHOLASTTIME H-F Ho Last Time BSC6900 SET GCELLHOBASIC(Optional) According to the P/N rule, if the conditions for the handover from half rate to full rate are met for P seconds within N seconds, the handover is triggered.This parameter specifies the number P. GBFD-510501HUAWEI II Handover Interval Type 1~16 1~16 s None 2 Cell This parameter is valid only when "HOCTRLSWITCH" is set to HOALGORITHM2. The following condition must be met: "HALFTOFULLHOSTATTIME" >= "HALFTOFULLHOLASTTIME". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
HALFTOFULLHOPATHOFFSET H-F Pathloss Offset Overlay BSC6900 SET GCELLHOBASIC(Optional) Path loss difference between the overlaid and underlaid subcells GBFD-510501HUAWEI II Handover Interval Type 0~255 0~255 dB None 10 Cell This parameter is valid only when "HOCTRLSWITCH" is set to HOALGORITHM2. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
HALFTOFULLHOSTATTIME H-F Ho Stat. Time BSC6900 SET GCELLHOBASIC(Optional) According to the P/N rule, if the conditions for the handover from half rate to full rate are met for P seconds within N seconds, the handover is triggered.This parameter specifies the number N. GBFD-510501HUAWEI II Handover Interval Type 1~16 1~16 s None 3 Cell This parameter is valid only when "HOCTRLSWITCH" is set to HOALGORITHM2. The following condition must be met: "HALFTOFULLHOSTATTIME" >= "HALFTOFULLHOLASTTIME". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
HANDOVERCTHD Handover control threshold BSC6900 SET FCCPUTHD(Optional) CPU usage threshold for handover control. When the average CPU usage of sliding windows reaches or exceeds the threshold, handover flow control is triggered. This parameter is valid only when "Board Class" is "XPU". WRFD-040100Flow Control Interval Type 30~100 30~100 per cent None 95 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
HANDOVERCTHD Handover control threshold BSC6900 SET FCMSGQTHD(Optional) Packet queue usage threshold for handover control. When the average packet queue usage of sliding windows reaches or exceeds the threshold, handover flow control is triggered. This parameter is valid only when "Board Class" is "XPU". WRFD-040100Flow Control Interval Type 30~100 30~100 per cent None 75 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
HANDOVERRTHD Handover restore threshold BSC6900 SET FCCPUTHD(Optional) CPU usage threshold for recovery from handover control. When the average CPU usage of sliding windows is lower than the threshold, handover flow control is stopped. This parameter is valid only when "Board Class" is "XPU". WRFD-040100Flow Control Interval Type 30~100 30~100 per cent None 85 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
HANDOVERRTHD Handover restore threshold BSC6900 SET FCMSGQTHD(Optional) Packet queue usage threshold for recovery from handover control. When the average packet queue usage of sliding windows is lower than the threshold, handover flow control is stopped. This parameter is valid only when "Board Class" is "XPU". WRFD-040100Flow Control Interval Type 30~100 30~100 per cent None 65 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
HANDOVERSW Handover flow control switch BSC6900 SET FCSW(Optional) Whether to control handover flow WRFD-040100Flow Control Enumeration Type ON, OFF ON, OFF None None ON Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
HAVETT1 Antenna Tributary 1 Flag BSC6900 SET BTSRXUBP(Optional) Whether to configure the TMA on antenna tributary 1 GBFD-111202O&M of BTS Enumeration Type NO(NO), YES(YES) NO, YES None NO None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
HAVETT2 Antenna Tributary 2 Flag BSC6900 SET BTSRXUBP(Optional) Whether to configure the TMA on antenna tributary 2 GBFD-111202O&M of BTS Enumeration Type NO(NO), YES(YES) NO, YES dB NO None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
HBINTER Heartbeat interval BSC6900 ADD SCTPLNK(Optional) Heartbeat interval when the SCTP server is idle. None None Interval Type 1000~600000 1000~600000 ms None 5000 SCTP linkNone Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
HCN Head Cabinet No. BSC6900 ADD BTSRXUCHAIN(Mandatory) Number of the cabinet where the head board of the RXU chain or ring is located GBFD-111202O&M of BTS Interval Type 0~62 0~62 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
HCSLASTTIME HCS HO valid time BSC6900 SET GCELLHOBASIC(Optional) According to the P/N rule, if the conditions for the handover to a different micro cell due to fast movement are met in P of N measurement reports, the handover is triggered.This parameter specifies the number P. GBFD-510501HUAWEI II Handover Interval Type 1~16 1~16, step:0.5 s None 2 Cell This parameter is valid only when "HOCTRLSWITCH" is set to HOALGORITHM2. The following condition must be met: "HCSSTATTIME" >= "HCSLASTTIME". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
HCSSTATTIME HCS HO watch time BSC6900 SET GCELLHOBASIC(Optional) According to the P/N rule, if the conditions for the handover to a different micro cell due to fast movement are met in P of N measurement reports, the handover is triggered.This parameter specifies the number N. GBFD-510501HUAWEI II Handover Interval Type 1~16 1~16, step:0.5 s None 3 Cell This parameter is valid only when "HOCTRLSWITCH" is set to HOALGORITHM2. The following condition must be met: "HCSSTATTIME" >= "HCSLASTTIME". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
HDBKGDL UMTS HSDPA background service downlink factor BSC6900 ADD TRMFACTOR(Optional) WCDMA HSDPA background service downlink factor None None Interval Type 0~100 0~100 per cent 100 100 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node that is configured with the factor table. After the successful modification, the parameter takes effect in the following two cases:1. New access subscriber. 2. Bandwidth modification of the existing subscriber
HDBKGPRIPATH HSDPA background primary path BSC6900 ADD TRMMAP(Optional) HSDPA background service bearer primary path None None Enumeration Type CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF None None When the interface type is Iub, transmission type is ATM, the parameter is UBR; transimssion type is dual stack or IP, the parameter is AF13; transimssion type is dual stack or Hybird IP, the parameter is LQAF13.When the interface type is Iur, transmission type is ATM, the parameter is UBR; transimssion type is IP, the parameter is AF13. BSC6900When the value of "ITFT" in "ADD TRMMAP" is set to IUB or IUR, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node configured with the TRMMAP. After the successful modification, it is valid in the case of the new access of a subscriber and the bandwidth modification of an existing subscriber.
HDBKGSECPATH HSDPA background secondary path BSC6900 ADD TRMMAP(Optional) HSDPA background service bearer secondary path None None Enumeration Type CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF, NULL CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF, NULL None None When the interface type is Iub, transmission type is ATM or IP, the parameter is NULL; transimssion type is dual stack, the parameter is UBR; transimssion type is Hybird IP, the parameter is AF13.When the interface type is Iur, transmission type is ATM or IP, the parameter is NULL. BSC6900When the value of "ITFT" in "ADD TRMMAP" is set to IUB or IUR, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node configured with the TRMMAP. After the successful modification, it is valid in the case of the new access of a subscriber and the bandwidth modification of an existing subscriber.
HDCONVDL UMTS HSDPA conversational service downlink factor BSC6900 ADD TRMFACTOR(Optional) WCDMA HSDPA conversational service downlink factor None None Interval Type 0~100 0~100 per cent 70 70 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node that is configured with the factor table. After the successful modification, the parameter takes effect in the following two cases:1. New access subscriber. 2. Bandwidth modification of the existing subscriber
HDCONVPRIPATH HSDPA conversational primary path BSC6900 ADD TRMMAP(Optional) HSDPA conversational service bearer primary path None None Enumeration Type CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF None None When the interface type is Iub, transmission type is ATM or dual stack, the parameter is RT_VBR; transimssion type is IP or Hybird IP, the parameter is AF33.When the interface type is Iur, transmission type is ATM, the parameter is RT_VBR; transimssion type is IP, the parameter is AF43. BSC6900When the value of "ITFT" in "ADD TRMMAP" is set to IUB or IUR, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node configured with the TRMMAP. After the successful modification, it is valid in the case of the new access of a subscriber and the bandwidth modification of an existing subscriber.
HDCONVSECPATH HSDPA conversational secondary path BSC6900 ADD TRMMAP(Optional) HSDPA conversational service bearer secondary path None None Enumeration Type CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF, NULL CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF, NULL None None When the interface type is Iub, transmission type is ATM or IP, the parameter is NULL; transimssion type is dual stack, the parameter is AF43; transimssion type is Hybird IP, the parameter is LQAF33.When the interface type is Iur, transmission type is ATM or IP, the parameter is NULL. BSC6900When the value of "ITFT" in "ADD TRMMAP" is set to IUB or IUR, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node configured with the TRMMAP. After the successful modification, it is valid in the case of the new access of a subscriber and the bandwidth modification of an existing subscriber.
HDINTERDL UMTS HSDPA interactive service downlink factor BSC6900 ADD TRMFACTOR(Optional) WCDMA HSDPA interactive service downlink factor None None Interval Type 0~100 0~100 per cent 100 100 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node that is configured with the factor table. After the successful modification, the parameter takes effect in the following two cases:1. New access subscriber. 2. Bandwidth modification of the existing subscriber
HDINTHGHPRIPATH HSDPA high PRI interactive primary path BSC6900 ADD TRMMAP(Optional) HSDPA high PRI interactive primary path None None Enumeration Type CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF None None When the interface type is Iub, transmission type is ATM, the parameter is UBR; transimssion type is dual stack or IP, the parameter is AF23; transimssion type is dual stack or Hybird IP, the parameter is LQAF23.When the interface type is Iur, transmission type is ATM, the parameter is UBR; transimssion type is IP, the parameter is AF23. BSC6900When the value of "ITFT" in "ADD TRMMAP" is set to IUB or IUR, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node configured with the TRMMAP. After the successful modification, it is valid in the case of the new access of a subscriber and the bandwidth modification of an existing subscriber.
HDINTHGHSECPATH HSDPA high PRI interactive secondary path BSC6900 ADD TRMMAP(Optional) HSDPA high PRI interactive secondary path None None Enumeration Type CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF, NULL CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF, NULL None None When the interface type is Iub, transmission type is ATM or IP, the parameter is NULL; transimssion type is dual stack, the parameter is UBR; transimssion type is Hybird IP, the parameter is AF23.When the interface type is Iur, transmission type is ATM or IP, the parameter is NULL. BSC6900When the value of "ITFT" in "ADD TRMMAP" is set to IUB or IUR, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node configured with the TRMMAP. After the successful modification, it is valid in the case of the new access of a subscriber and the bandwidth modification of an existing subscriber.
HDINTLOWPRIPATH HSDPA low PRI interactive primary path BSC6900 ADD TRMMAP(Optional) HSDPA low PRI interactive primary path None None Enumeration Type CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF None None When the interface type is Iub, transmission type is ATM, the parameter is UBR; transimssion type is dual stack or IP, the parameter is AF23; transimssion type is dual stack or Hybird IP, the parameter is LQAF23.When the interface type is Iur, transmission type is ATM, the parameter is UBR; transimssion type is IP, the parameter is AF23. BSC6900When the value of "ITFT" in "ADD TRMMAP" is set to IUB or IUR, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node configured with the TRMMAP. After the successful modification, it is valid in the case of the new access of a subscriber and the bandwidth modification of an existing subscriber.
HDINTLOWSECPATH HSDPA low PRI interactive secondary path BSC6900 ADD TRMMAP(Optional) HSDPA low PRI interactive secondary path None None Enumeration Type CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF, NULL CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF, NULL None None When the interface type is Iub, transmission type is ATM or IP, the parameter is NULL; transimssion type is dual stack, the parameter is UBR; transimssion type is Hybird IP, the parameter is AF23.When the interface type is Iur, transmission type is ATM or IP, the parameter is NULL. BSC6900When the value of "ITFT" in "ADD TRMMAP" is set to IUB or IUR, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node configured with the TRMMAP. After the successful modification, it is valid in the case of the new access of a subscriber and the bandwidth modification of an existing subscriber.
HDINTMIDPRIPATH HSDPA middle PRI interactive primary path BSC6900 ADD TRMMAP(Optional) HSDPA middle PRI interactive primary path None None Enumeration Type CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF None None When the interface type is Iub, transmission type is ATM, the parameter is UBR; transimssion type is dual stack or IP, the parameter is AF23; transimssion type is dual stack or Hybird IP, the parameter is LQAF23.When the interface type is Iur, transmission type is ATM, the parameter is UBR; transimssion type is IP, the parameter is AF23. BSC6900When the value of "ITFT" in "ADD TRMMAP" is set to IUB or IUR, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node configured with the TRMMAP. After the successful modification, it is valid in the case of the new access of a subscriber and the bandwidth modification of an existing subscriber.
HDINTMIDSECPATH HSDPA middle PRI interactive secondary path BSC6900 ADD TRMMAP(Optional) HSDPA middle PRI interactive secondary path None None Enumeration Type CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF, NULL CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF, NULL None None When the interface type is Iub, transmission type is ATM or IP, the parameter is NULL; transimssion type is dual stack, the parameter is UBR; transimssion type is Hybird IP, the parameter is AF23.When the interface type is Iur, transmission type is ATM or IP, the parameter is NULL. BSC6900When the value of "ITFT" in "ADD TRMMAP" is set to IUB or IUR, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node configured with the TRMMAP. After the successful modification, it is valid in the case of the new access of a subscriber and the bandwidth modification of an existing subscriber.
HDSIPDL UMTS HSDPA IMS signal downlink factor BSC6900 ADD TRMFACTOR(Optional) WCDMA HSDPA IMS signaling downlink factor None None Interval Type 0~100 0~100 per cent 15 15 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node that is configured with the factor table. After the successful modification, the parameter takes effect in the following two cases:1. New access subscriber. 2. Bandwidth modification of the existing subscriber
HDSIPPRIPATH HSDPA IMS Signal primary path BSC6900 ADD TRMMAP(Optional) HSDPA IMS signaling bearer primary path None None Enumeration Type CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF None None When the interface type is Iub, transmission type is ATM or dual stack, the parameter is RT_VBR; transimssion type is IP or Hybird IP, the parameter is EF.When the interface type is Iur, transmission type is ATM, the parameter is RT_VBR; transimssion type is IP, the parameter is EF. BSC6900When the value of "ITFT" in "ADD TRMMAP" is set to IUB or IUR, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node configured with the TRMMAP. After the successful modification, it is valid in the case of the new access of a subscriber and the bandwidth modification of an existing subscriber.
HDSIPSECPATH HSDPA IMS Signal secondary path BSC6900 ADD TRMMAP(Optional) HSDPA IMS signaling bearer secondary path None None Enumeration Type CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF, NULL CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF, NULL None None When the interface type is Iub, transmission type is ATM or IP, the parameter is NULL; transimssion type is dual stack, the parameter is EF; transimssion type is Hybird IP, the parameter is LQEF.When the interface type is Iur, transmission type is ATM or IP, the parameter is NULL. BSC6900When the value of "ITFT" in "ADD TRMMAP" is set to IUB or IUR, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node configured with the TRMMAP. After the successful modification, it is valid in the case of the new access of a subscriber and the bandwidth modification of an existing subscriber.
HDSRBDL UMTS HSDPA signal downlink factor BSC6900 ADD TRMFACTOR(Optional) WCDMA HSDPA signaling downlink factor None None Interval Type 0~100 0~100 per cent 50 50 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node that is configured with the factor table. After the successful modification, the parameter takes effect in the following two cases:1. New access subscriber. 2. Bandwidth modification of the existing subscriber
HDSRBPRIPATH HSDPA Signal primary path BSC6900 ADD TRMMAP(Optional) HSDPA signaling bearer primary path None None Enumeration Type CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF None None When the interface type is Iub, transmission type is ATM or dual stack, the parameter is RT_VBR; transimssion type is IP or Hybird IP, the parameter is EF.When the interface type is Iur, transmission type is ATM, the parameter is RT_VBR; transimssion type is IP, the parameter is EF. BSC6900When the value of "ITFT" in "ADD TRMMAP" is set to IUB or IUR, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node configured with the TRMMAP. After the successful modification, it is valid in the case of the new access of a subscriber and the bandwidth modification of an existing subscriber.
HDSRBSECPATH HSDPA Signal secondary path BSC6900 ADD TRMMAP(Optional) HSDPA signaling bearer secondary path None None Enumeration Type CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF, NULL CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF, NULL None None When the interface type is Iub, transmission type is ATM or IP, the parameter is NULL; transimssion type is dual stack, the parameter is EF; transimssion type is Hybird IP, the parameter is LQEF.When the interface type is Iur, transmission type is ATM or IP, the parameter is NULL. BSC6900When the value of "ITFT" in "ADD TRMMAP" is set to IUB or IUR, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node configured with the TRMMAP. After the successful modification, it is valid in the case of the new access of a subscriber and the bandwidth modification of an existing subscriber.
HDSTRMDL UMTS HSDPA streaming service downlink factor BSC6900 ADD TRMFACTOR(Optional) HSDPA streaming service downlink factor None None Interval Type 0~100 0~100 per cent 100 100 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node that is configured with the factor table. After the successful modification, the parameter takes effect in the following two cases:1. New access subscriber. 2. Bandwidth modification of the existing subscriber
HDSTRMPRIPATH HSDPA streaming primary path BSC6900 ADD TRMMAP(Optional) HSDPA streaming service bearer primary path None None Enumeration Type CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF None None When the interface type is Iub, transmission type is ATM or dual stack, the parameter is RT_VBR; transimssion type is IP or Hybird IP, the parameter is AF33.When the interface type is Iur, transmission type is ATM, the parameter is RT_VBR; transimssion type is IP, the parameter is AF43. BSC6900When the value of "ITFT" in "ADD TRMMAP" is set to IUB or IUR, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node configured with the TRMMAP. After the successful modification, it is valid in the case of the new access of a subscriber and the bandwidth modification of an existing subscriber.
HDSTRMSECPATH HSDPA streaming secondary path BSC6900 ADD TRMMAP(Optional) HSDPA streaming service bearer secondary path None None Enumeration Type CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF, NULL CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF, NULL None None When the interface type is Iub, transmission type is ATM or IP, the parameter is NULL; transimssion type is dual stack, the parameter is AF43; transimssion type is Hybird IP, the parameter is LQAF33.When the interface type is Iur, transmission type is ATM or IP, the parameter is NULL. BSC6900When the value of "ITFT" in "ADD TRMMAP" is set to IUB or IUR, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node configured with the TRMMAP. After the successful modification, it is valid in the case of the new access of a subscriber and the bandwidth modification of an existing subscriber.
HDVOICEDL UMTS HSDPA voice service downlink factor BSC6900 ADD TRMFACTOR(Optional) WCDMA HSDPA voice service downlink factor None None Interval Type 0~100 0~100 per cent 70 70 Adjacent node None Read & Write N (No impact on the UE in idle mode) Not involved Not involved If the parameter is modified, the transport layer bandwidth admission of the subsequence access service is affected.
HDVOICEPRIPATH HSDPA Voice primary path BSC6900 ADD TRMMAP(Optional) HSDPA voice service bearer primary path None None Enumeration Type CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF None None When the interface type is Iub, transmission type is ATM or dual stack, the parameter is RT_VBR; transimssion type is IP or Hybird IP, the parameter is AF33.When the interface type is Iur, transmission type is ATM, the parameter is RT_VBR; transimssion type is IP, the parameter is AF43. BSC6900When the value of "ITFT" in "ADD TRMMAP" is set to IUB or IUR, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node configured with the TRMMAP. After the successful modification, it is valid in the case of the new access of a subscriber and the bandwidth modification of an existing subscriber.
HDVOICESECPATH HSDPA Voice secondary path BSC6900 ADD TRMMAP(Optional) HSDPA voice service bearer secondary path None None Enumeration Type CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF, NULL CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF, NULL None None When the interface type is Iub, transmission type is ATM or IP, the parameter is NULL; transimssion type is dual stack, the parameter is AF43; transimssion type is Hybird IP, the parameter is LQAF33.When the interface type is Iur, transmission type is ATM or IP, the parameter is NULL. BSC6900When the value of "ITFT" in "ADD TRMMAP" is set to IUB or IUR, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node configured with the TRMMAP. After the successful modification, it is valid in the case of the new access of a subscriber and the bandwidth modification of an existing subscriber.
HIERPWRPARA1 Hierarchical Power Para1 BSC6900 SET BTSBAT(Optional) Threshold for interrupting the power supply to the TRXs. If the BTS works with the battery power supply, when the battery voltage is less than this threshold, the BTS interrupts the power supply to the TRXs to protect the lower-level BTSs from being affected. GBFD-111202O&M of BTS Interval Type 0~65535 0~65535 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter is supported only by the BTS3002C.
HIERPWRPARA2 Hierarchical Power Para2 BSC6900 SET BTSBAT(Optional) Threshold for interrupting the power supply to the TMU. If the BTS works with the battery power supply, when the battery voltage is less than this threshold, the BTS interrupts the power supply to the TMU. GBFD-111202O&M of BTS Interval Type 0~65535 0~65535 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter is supported only by the BTS3002C.
HiFreqBandSupport Support High Frequency Band BSC6900 SET BSCBASIC(Optional) Type of a high frequency type supported by the BSC.Frequencies on DCS1800: 512-885Frequencies on PCS1900: 512-810 GBFD-110101Frequency Band Enumeration Type DCS1800, PCS1900 DCS1800, PCS1900 None None DCS1800 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved If the TRXs in a cell under this BSC are at a frequency on DCS1800, this parameter cannot be set to PCS1900, and vice versa.
HIGHESTPRIORITQUALFIRST Highest priority for quality first BSC6900 SET GCELLCHMGBASIC(Optional) Full rate TCHs are assigned preferentially to the MSs with priority levels equal to or less than this threshold, except when the MSs request only half or full rate TCHs. GBFD-115001Enhanced Multi Level Precedence and Preemption(EMLPP) Interval Type 1~14 1~14 None None 1 Cell This parameter is valid only when "HIGHPRIUSERQUALFIRST" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
HIGHPRIUSERQUALFIRST Highest priority user quality first BSC6900 SET GCELLCHMGBASIC(Optional) Whether to enable the priority-based channel assignment algorithm GBFD-115001Enhanced Multi Level Precedence and Preemption(EMLPP) Enumeration Type NO(No), YES(Yes)NO, YES None None NO Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved When this parameter is set to No, Highest Priority cannot be configured.
HIGHTEMPLOADPWROFF High Temp Load Pwr Off BSC6900 SET BTSAPMUBP(Optional) Whether to enable load power-off against high temperature GBFD-111202O&M of BTS Enumeration Type NO(NO), YES(YES) NO, YES None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
HISPRIOALLOW History Record Priority Allowed BSC6900 SET GCELLCHMGAD(Optional) Whether to consider history priority records during channel assignmentIf this parameter is set to YES, the history priority records are considered. If this parameter is set to NO, the history priority records are not considered. GBFD-111005Enhanced Channel Assignment Algorithm Enumeration Type NO(No), YES(Yes)NO, YES None None YES Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
HMCDTM Support HMC DTM BSC6900 SET GCELLGPRS(Optional) Whether the cell supports the MS with the DTM multi-timeslot capability. GBFD-119404HMC DTM Enumeration Type UNSUPPORT(Not Support), SUPPORT(Support) UNSUPPORT, SUPPORT None None None Cell This parameter is valid only when "GPRS" is set to SupportAsInnPcu and "SUPPORTDTM" is set to SUPPORT. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
HOALGOPERMLAY Pref. Subcell in HO of Intra-BSC BSC6900 SET GCELLHOIUO(Optional) Whether to assign a channel in the overlaid or underlaid subcell in the case of the intra-BSC incoming handover to the concentric cellIf this parameter is set to SysOpt, the measured BCCH of the target cell is included in the intra-BSC inter-cell handover request message. Then, the BSC compares the measured value with "RX_LEV Threshold" to choose the preferred subcell. During this course, the BSC does not consider "RX_LEV Hysteresis".If this parameter is set to OSubcell, a channel in the overlaid subcell is assigned preferentially.If this parameter is set to USubcell, a channel in the underlaid subcell is assigned preferentially.If this parameter is set to NoPrefer, a channel is assigned simply according to channel assignment algorithms. GBFD-113201Concentric Cell Enumeration Type SysOpt(System optimization), OSubcell(Overlaid subcell), USubcell(Underlaid subcell), NoPrefer(No preference) SysOpt, OSubcell, USubcell, NoPrefer None None SysOpt Cell This parameter is valid only when "IUOTP" in "ADD GCELL" is set to Concentric_cell. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
HOBTWNOTHOPALLOW Handover Between Operators Allow BSC6900 ADD GCNOPERATOR(Optional) Whether to allow handover between different operators. If the BSC supports RAN sharing, MSs in a cell of this operator can be handed over to a cell of other operators, or vice versa. GBFD-118701RAN Sharing Enumeration Type NO(No), YES(Yes)NO, YES None NO NO BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
HOCDCMINDWPWR Min DL Level on Candidate Cell BSC6900 SET GCELLHOBASIC(Optional) If the downlink received signal level of a neighbor cell is greater than "Min DL Level on Candidate Cell" plus "Min Access Level Offset", the neighbor cell can be listed in the candidate cell queue for handover. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 0~63 0~63 dB None 10 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
HOCDCMINUPPWR Min UL Level on Candidate Cell BSC6900 SET GCELLHOBASIC(Optional) If the uplink received signal level of a neighbor cell is greater than "Min UL Level on Candidate Cell" plus "Min Access Level Offset", the neighbor cell can be listed in the candidate cell queue for handover. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 0~63 0~63 dB None 0 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
HOCELLIDTYPE Specify Index of Cell Handover to BSC6900 SET FHO(Mandatory) Type of indexing the target cell GBFD-111202O&M of BTS Enumeration Type BYCELLNAME(By cell name), BYCGI(By CGI) BYCELLNAME, BYCGI None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
HOCELLNAME Cell Name of Handover to BSC6900 SET FHO(Mandatory) Unique name of the target cell GBFD-111202O&M of BTS String Type None 1~64 characters None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
HOCTRLSWITCH Current HO Control Algorithm BSC6900 SET GCELLHOBASIC(Optional)SET GCELLHOEMG(Optional)SET GCELLHOFITPEN(Optional)SET GCELLHOIUO(Optional) Whether to use handover algorithm generation 1 or 2 currently MRFD-210301Configuration Management Enumeration Type HOALGORITHM1(Handover algorithm I), HOALGORITHM2(Handover algorithm II) HOALGORITHM1, HOALGORITHM2 None None None Cell The value of this parameter must be the same as that of "HOCTRLSWITCH" in "SET GCELLHOBASIC". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
HODIRFORECASTEN Handover Direction Forecast Enable BSC6900 SET GCELLHOFAST(Optional) Handover directio forcast switch. When this parameter is set to YES, the BSC can forecast the handover direction of the call in fast handover so that the best target cell can be selected for handover. GBFD-510103Chain Cell Handover Enumeration Type NO(No), YES(Yes)NO, YES None NO NO Cell When parameter "Quick handover enable" is configured to "YES",then parameter "Handover Direction Forecast Enable" can be configured to "YES". Furthermore,before open "Handover Direction Forecast Enable", parameter "Chain Neighbour Cell Type" of cell should be configured correctly. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
HODIRLASTTIME Handover Direction Forecast Last Times BSC6900 SET GCELLHOFAST(Optional) This parameter indicates P in the P/N rule for MS handover direction forcast. P/N rule: Among N handovers, the MS is handed over to Class B chain neighboring cell for successively P times, then the MBSC determines that the MS is moving to the Class B chain neighboring cell. GBFD-510103Chain Cell Handover Interval Type 0~16 0~16 None 3 3 Cell "Handover Direction Forecast Statistic Times" >= "Handover Direction Forecast Last Times" Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
HODIRSTATIME Handover Direction Forecast Statistic Times BSC6900 SET GCELLHOFAST(Optional) This parameter indicates N in the P/N rule for MS handover direction forcast. P/N rule: Among N handovers, the MS is handed over to Class B chain neighboring cell for successively P times, then the MBSC determines that the MS is moving to the Class B chain neighboring cell. GBFD-510103Chain Cell Handover Interval Type 0~16 0~16 None 3 3 Cell "Handover Direction Forecast Statistic Times" >= "Handover Direction Forecast Last Times" Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
HODOWNTRIGE Quick handover down triger level BSC6900 SET GCELLHOFAST(Optional) Fast handover can be triggered only when the downlink level of the serving cell is less than this parameter. GBFD-510102Fast Move Handover Interval Type 0~63 0~63 dB None 50 Cell This parameter is valid only when "QUICKHOEN" in "SET GCELLHOBASIC" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
HODURT3G 3G Better Cell HO Valid Time BSC6900 SET GCELLHOUTRANFDD(Optional)SET GCELLHOUTRANTDD(Optional) According to the P/N rule, if the conditions for the handover to a better 3G cell are met for P seconds within N seconds, the handover is triggered.This parameter specifies the number P. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 1~16 1~16 s None 4 Cell This parameter is valid only when "BET3GHOEN" is set to YES. The following condition must be met: "HOSTAT3G" >= "HODURT3G". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
HOECNOTH3G Ec/no threshold for better 3g cell ho BSC6900 SET GCELLHOUTRANFDD(Optional) The handover to a better 3G cell can be triggered only when the Ec/No of the 3G neighbor cell is greater than this threshold. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 0~49 0~49 dB None 35 Cell This parameter is valid only when "INTERRATOUTBSCHOEN" is set to YES and "BET3GHOEN" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
HOLASTTIME Quick handover last time BSC6900 SET GCELLHOFAST(Optional) According to the P/N rule, if the conditions for fast handover are met in P of N measurement reports, the handover is triggered.This parameter specifies the number P. GBFD-510102Fast Move Handover Interval Type 1~32 1~32, step:0.5 s None 3 Cell This parameter is valid only when "QUICKHOEN" in "SET GCELLHOBASIC" is set to YES. The following condition must be met: "HOSTATICTIME" >= "HOLASTTIME". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
HOMOD Handover Scope BSC6900 SET FHO(Mandatory) Type of handover in terms of connection transfer between chnnels or between cells GBFD-111202O&M of BTS Enumeration Type FREE(Free), INCELL(Intra-cell), OUTCELL(Outgoing cell), OUTST(Outgoing site), OUTBSC(Outgoing BSC), OUTSYS(Outgoing system), SPCELL(Specified cell) FREE, INCELL, OUTCELL, OUTST, OUTBSC, OUTSYS, SPCELL None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
HOOFFSET Quick handover offset BSC6900 ADD GEXT2GCELL(Optional)SET GCELLHOFAST(Optional) Fast handover can be triggered only when the path loss difference between the serving cell and a neighbor cell on the chain is equal to or greater than this parameter. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 0~127 0~127 dB None 68 Cell This parameter is valid only when "QUICKHOEN" in "SET GCELLHOBASIC" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
HOOLRXLEVOFFSET Handover to Underlayer RxLev Offset BSC6900 SET GCELLCHMGAD(Optional) If the cell is an enhanced concentric cell, this parameter with the current downlink received signal level and "UtoO HO Received Level Threshold" determines whether to assign a channel in the underlaid subcell to the intra-BSC incoming handover to the concentric cell or intra-BSC inter-cell handover.If the cell is an ordinary concentric cell, this parameter with the current downlink received signal level, "RX_LEV Threshold", and "RX_LEV Hysteresis" determines whether to assign a channel in the underlaid subcell to the intra-BSC incoming handover to the concentric cell or intra-BSC inter-cell handover. GBFD-113201Concentric Cell Interval Type 0~61 0~61 dB None 32 Cell This parameter is valid only when "LOWRXLEVOLFORBIDSWITCH" is set to ON. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
HOOPTSEL Inter-rat ho preference BSC6900 SET GCELLHOUTRANFDD(Optional)SET GCELLHOUTRANTDD(Optional) Whether to prefer a 2G or 3G cell as the handover target cellIf this parameter is set to Pre_2G_Cell, the BSC prefers a 2G cell candidate as the handover target cell.If this parameter is set to Pre_3G_Cell, the BSC prefers a 3G cell candidate as the handover target cell.If this parameter is set to Pre_2G_CellThres, when the received level of the first 2G neighbor cell candidate is equal to or less than "HO Preference Threshold for 2G Cell", the BSC prefers a 3G cell candidate as the handover target cell. When the received level of the first 2G neighbor cell candidate is greater than "HO Preference Threshold for 2G Cell", the BSC prefers the 2G cell candidate as the handover target cell. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Enumeration Type Pre_2G_Cell(Preference for 2G cell), Pre_3G_Cell(Preference for 3G cell), Pre_2G_CellThres(Preference 2G cell by thresh) Pre_2G_Cell, Pre_3G_Cell, Pre_2G_CellThres None None Pre_2G_CellThres Cell This parameter is valid only when "INTERRATOUTBSCHOEN" in "SET GCELLHOBASIC" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
HOPENALTYTIME Inter UL/OL Subcells HO Penalty Time BSC6900 SET GCELLHOEDBPARA(Optional) An MS cannot be handed over from the underlaid subcell to the overlaid subcell in this duration after the MS is handed over from the overlaid subcell to the underlaid subcell successfully. GBFD-114402Enhanced Dual-Band Network Interval Type 0~255 0~255 s None 5 Cell This parameter is valid only when "IUOTP" in "ADD GCELL" is set to EDB_cell. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
HOPINDEX Hop Index BSC6900 ADD GCELLMAGRP(Mandatory) Index of the frequency hopping data, used for a TRX to locate the frequency hopping sequence GBFD-113701Frequency Hopping (RF hopping, baseband hopping) Interval Type 0~63 0~63 None None None Cell None Read & Write Not involved Not involved Not involved The value of this parameter cannot be changed.
HOPINDEX Hop Index BSC6900 SET GCELLMAIOPLAN(Mandatory) Logical number of the MA group GBFD-117002IBCA (Interference Based Channel Allocation) Interval Type 0~63 0~63 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
HOPMODE Hop Mode BSC6900 ADD GCELLMAGRP(Mandatory) Implementation mode of frequency hopping GBFD-113701Frequency Hopping (RF hopping, baseband hopping) Enumeration Type BaseBand_FH(Baseband FH), RF_FH(RF FH) Baseband_FH, RF_FHNone None None Cell None Read & Write Y Cell Less than 1 minute The value of this parameter must be the same as the attribute value of the TRX frequency hopping of this frequency hopping group.
HOPOWERBOOST Power Boost before HO Enabled or Not BSC6900 SET GCELLOTHBASIC(Optional) Whether to enable power boost before handover.When the receive level of an MS drops rapidly, a handover occurs. In this case, the BSC cannot adjust the transmit power of the MS and the BTS in time. The MS may fail to receive a handover command, thus leading to a call drop. If the value of this parameter is YES (StartUp), the transmit power of the BTS is adjusted to the maximum before the BSC sends a handover command to the MS. In addition, the transmit power of the BTS is not adjusted during the handover for the purpose of ensuring the success of the handover. GBFD-117101BTS power lift for handover Enumeration Type NO(Not StartUp), YES(StartUp), NONE(None) NO, YES, NONE None None YES Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
HOPRETH2G HO Preference Threshold for 2G Cell BSC6900 SET GCELLHOUTRANFDD(Optional)SET GCELLHOUTRANTDD(Optional) If the received level of the first 2G neighbor cell candidate is equal to or less than this threshold, the BSC prefers a 3G cell candidate as the handover target cell. If the received level of the first 2G neighbor cell candidate is greater than this threshold, the BSC prefers the 2G cell candidate as the handover target cell. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 0~63 0~63 dB None 25 Cell This parameter is valid only when "HOOPTSEL" is set to Pre_2G_CellThres. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
HopSingleFreqOptSwitch Hop Group Single Freq Optimization BSC6900 SET OTHSOFTPARA(Optional) If this parameter is set to ON, the channel on a single frequency of an MA group is allocated to an MS with the non-FH attribute. GBFD-113701Frequency Hopping (RF hopping, baseband hopping) Enumeration Type OFF(Off), ON(On) OFF, ON None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
HOPTRXHSN Hop TRX Group HSN BSC6900 ADD GCELLHOPANTGRP(Optional) Hoping sequence number (HSN) of a hopping antenna group. If the value of this parameter is 0, the services over a TRX are adjusted to other TRXs in the hopping antenna group in sequence. If this parameter is set to a value from 1 to 63, the services over a TRX are adjusted to other TRXs in the hopping antenna group in a pseudo-random manner. GBFD-113703Antenna Frequency Hopping Interval Type 0~63 0~63 None 0 0 Cell None Read & Write Y Cell Less than 1 minute None
HOPTRXINDEX Hop TRX Group Index BSC6900 ADD GCELLHOPANTGRP(Mandatory) TRX index that a hopping antenna index corresponds to. A hopping antenna enables signals of multiple TRXs to switch between several antennas instead of fixing an antenna for a TRX. This reduces the effect of Rayleigh fading on signals of some frequencies. GBFD-113703Antenna Frequency Hopping Interval Type 0~23 0~23 None None None Cell None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
HOPTYPE Hop Type BSC6900 SET GTRXHOP(Optional) Frequency hopping mode of the TRX. Frequency hopping assists in interference averaging and frequency diversity.If this parameter is set to RF_FH, the TX and RX parts of the TRX take part in the frequency hopping. In this case, the number of hopping frequencies can exceed the number of TRXs in the cell. If this parameter is set to BaseBand_FH, each transmitter works at a fixed frequency. That is, the TX part does not take part in the frequency hopping. The baseband signals are switched for the frequency-hopping transmission. The RX part, however, takes part in the frequency hopping. GBFD-113701Frequency Hopping (RF hopping, baseband hopping) Enumeration Type NO_FH(No Frequency Hopping), BaseBand_FH(Baseband Frequency Hopping), RF_FH(RF Frequency Hopping) NO_FH, BaseBand_FH, RF_FH None None None TRX This parameter depends on "FHMODE" in "SET GCELLHOPTP". This parameter can be set to BaseBand_FH only when "FHMODE" is set to BaseBand_FH or Hybrid_FH. This parameter can be set to RF_FH only when "FHMODE" is set to RF_FH or Hybrid_FH. Read & Write Services will be disrupted if the handover fails after the parameter modification. Cell Less than 1 minute After this parameter is modified, the services in the cell are handed over forcedly. The cell is reset (after ten seconds) after the handover succeeds. This protects the services from being interrupted.
HOPUNISHVALUE Quick handover punish value BSC6900 ADD GEXT2GCELL(Optional)SET GCELLHOFAST(Optional) To avoid ping-pong handover, the received signal of the original serving cell is decreased by "Quick handover punish value" in "Quick handover punish time" after fast handover succeeds. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 0~63 0~63 dB None 63 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
HOREFTMR BSC HO Protect Time BSC6900 ADD AISSCFG(Optional) Time for reserving the handover reference for one of the two BSCs that collect the offset information. GBFD-118201Soft-Synchronized Network Interval Type 1~60 1~60 min 15 None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None.
HORSCPTH3G RSCP Threshold for Better 3G Cell HO BSC6900 SET GCELLHOUTRANFDD(Optional)SET GCELLHOUTRANTDD(Optional) The handover to a better 3G cell is triggered only when the RSCP of the 3G neighbor cell is greater than this threshold during a period. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 0~63 0~63 dB None 50 Cell This parameter is valid only when "INTERRATOUTBSCHOEN" is set to YES and "BET3GHOEN" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
HoSdcchSpeechVer Speech VER in SDCCH HO REQ ACK BSC6900 SET MSGSOFTPARA(Optional) Whether an HO REQ ACK message contains the information element Speech Version during an SDCCH handover. If a signaling channel handover between BSCs fails, the value of this parameter may need to be adjusted. GBFD-111804A Interface Protocol Process Enumeration Type NO(No), YES(Yes)NO, YES None None YES MSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
HOSTAT3G 3G Better Cell HO Watch Time BSC6900 SET GCELLHOUTRANFDD(Optional)SET GCELLHOUTRANTDD(Optional) According to the P/N rule, if the conditions for the handover to a better 3G cell are met in P of N measurement reports, the handover is triggered.This parameter specifies the number N. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 1~16 1~16 s None 5 Cell This parameter is valid only when "INTERRATOUTBSCHOEN" is set to YES and "BET3GHOEN" is set to YES. The following condition must be met: "HOSTAT3G" >= "HODURT3G". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
HOSTATICTIME Quick handover static time BSC6900 SET GCELLHOFAST(Optional) According to the P/N rule, if the conditions for fast handover are met in P of N measurement reports, the handover is triggered.This parameter specifies the number N. GBFD-510102Fast Move Handover Interval Type 1~32 1~32, step:0.5 s None 4 Cell This parameter is valid only when "QUICKHOEN" in "SET GCELLHOBASIC" is set to YES. The following condition must be met: "HOSTATICTIME" >= "HOLASTTIME". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
HOSTTYPE The host type of signalling point BSC6900 ADD OPC(Optional) Host type of signaling point. None None Enumeration Type SINGLEHOST(SINGLEHOST), PRIMHOST(PRIMHOST), SLAVEHOST(SLAVEHOST) SINGLEHOST, PRIMHOST, SLAVEHOST None SINGLEHOST SINGLEHOST BSC6900None Read & Write Y BSC6900 The services are interrupted until the signaling point is available. Before the modification, the cell mapping table bound to the signaling point must be deleted.
HOSTTYPE HostType BSC6900 SET BTSIP(Optional) Host type of an IP BTS GBFD-113725BSC Node Redundancy Enumeration Type SINGLEHOST(Single Host), PRIMHOST(Primary Host), SLAVEHOST(Slave Host) SINGLEHOST, PRIMHOST, SLAVEHOST None None None BTS When the BTS or cell is activated,the host type of OPC must be single or primary if the host type of BTS is single.Otherwise, the host type of OPC must be consistent with that of the BTS. Read & Write Y BTS Less than 5 minutes None
HOTHRES Inter-layer HO threshold BSC6900 ADD GEXT2GCELL(Optional)SET GCELLHOBASIC(Optional) Handover threshold during the handovers between cells on different layers or of different priorities. This value is used to suppress inter-layer ping-pong handovers. Inter-layer handover threshold of the serving cell = "Inter-layer HO threshold" - "Inter-layer HO Hysteresis"; Inter-layer handover threshold of a neighboring cell = "Inter-layer HO threshold" + "Adjacent Cell Inter-layer HO Hysteresis" - 64. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 0~63 0~63 dB None 25 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved Set this parameter properly to ensure that hierarchical handover and load-based handover can function properly. During hierarchical handover and load-based handover, the downlink received level of the target cell must be greater than this threshold.
HOUPTRIGE Quick handover up triger level BSC6900 SET GCELLHOFAST(Optional) Fast handover can be triggered only when the uplink signal level of the serving cell is less than this parameter. GBFD-510102Fast Move Handover Interval Type 0~63 0~63 dB None 50 Cell This parameter is valid only when "QUICKHOEN" in "SET GCELLHOBASIC" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
HPANTMODE Cell Antenna Hopping BSC6900 SET GCELLHOPANT(Optional) Whether to enable the TRX to support antenna hoppingIn a GSM cell, the BCCH broadcasts the frequency, frame number, system information, and paging group. If an MS is in an unfavorable position or the antenna of the main TRX that carries the BCCH fails, the MS receives poor broadcast control signals or even cannot receive any broadcast control message from the BCCH. To avoid such as problem, the antenna hopping function is involved. With this function, the messages transmitted in the main TRX that carries the BCCH are also transmitted on the antennas of all the other TRXs in the cell in turn. This helps the MSs receive quality broadcast control data. This function can be configured only for dual-frequency BTSs. GBFD-113703Antenna Frequency Hopping Enumeration Type NO_HPANT(No), YES_HPANT(Yes), NONE(None) NO_HPANT, YES_HPANT, NONE None None None Cell None Read & Write Y Cell Less than 1 minute None
HPANTMODE Cell Antenna Hopping BSC6900 SET GCELLHOPANTQUICKSETUP(Mandatory) Whether to enable the TRX to support antenna hoppingIn a GSM cell, the BCCH broadcasts the frequency, frame number, system information, and paging group. If an MS is in an unfavorable position or the antenna of the main TRX that carries the BCCH fails, the MS receives poor broadcast control signals or even cannot receive any broadcast control message from the BCCH. To avoid such as problem, the antenna hopping function is involved. With this function, the messages transmitted in the main TRX that carries the BCCH are also transmitted on the antennas of all the other TRXs in the cell in turn. This helps the MSs receive quality broadcast control data. This function can be configured only for dual-frequency BTSs. GBFD-113703Antenna Frequency Hopping Enumeration Type NO_HPANT(No), YES_HPANT(Yes) NO_HPANT, YES_HPANT None None None Cell None Read & Write Y Cell Less than 1 minute None
HPN Head Port No. BSC6900 ADD BTSRXUCHAIN(Mandatory) The number of the optical port of the head board in the RXU chain or ring. GBFD-111202O&M of BTS Interval Type 0~5 0~5 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
HPRIOR Highest Priority BSC6900 SET GCELLCHMGBASIC(Optional) Maximum priority level of an MS that can use reserved channel resources. If the priority level of an MS is greater than this parameter, the MS is considered a low-priority MS. If the priority of an MS is equal to or less than this threshold, the MS is considered a high-priority MS. GBFD-116001Resource Reservation Interval Type 1~14 1~14 None None 1 Cell This parameter is valid only when "GRADEACCALLOW" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
HPVFLAG Hierarchical Power-off Config. Enabled BSC6900 SET BTSAPMUBP(Optional)SET BTSDPMUBP(Optional) Whether to enable the configuration of power system parameters.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. GBFD-111202O&M of BTS Enumeration Type NO(NO), YES(YES) NO, YES None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
HPVTHD Load Power-off Voltage BSC6900 SET BTSDPMUBP(Optional) Load power-off voltage threshold.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. GBFD-111202O&M of BTS Interval Type 432~553 43.2~55.3 (step: 0.1) V None None BTS The value of this parameter must be smaller than "DC Undervoltage Alarm Threshold". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
HRATESPT Support Half Rate BSC6900 SET GCELLCCCH(Optional) Whether to support the half-rate service in this cell. It is one of the cell reselection parameters in system message 3. GBFD-113401Half Rate Speech Enumeration Type NO(No), YES(Yes)NO, YES None None NO Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
HRDLDTX HR Use Downlink DTX BSC6900 SET GCELLBASICPARA(Optional) Whether the downlink discontinuous transmission (DTX) function is enabled for half rate (HR) calls. This function is also restricted by the DTX switch in the MSC. If the MSC allows the downlink DTX for calls and the value of this parameter is YES, the downlink DTX is enabled for HR calls of cells. GBFD-114801GBFD-113401 Discontinuous Transmission (DTX) DownlinkHalf Rate Speech Enumeration Type NO(No), YES(Yes)NO, YES None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
HRIUOLDRATESELALLOW load of UL-OL cells rate Select Allwd BSC6900 SET GCELLCHMGAD(Optional) Whether to enable the BSC to assign half or full rate channels to MSs according to the channel seizure ratio in the overlaid and underlaid subcells GBFD-113201Concentric Cell Enumeration Type NO(No), YES(Yes)NO, YES None None YES Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
HRULDTX HR Uplink DTX BSC6900 SET GCELLBASICPARA(Optional) Whether the uplink DTX function is enabled for HR calls. For details, see GSM Rec. 05.08. GBFD-114803GBFD-113401 Discontinuous Transmission (DTX) UplinkHalf Rate Speech Enumeration Type May_Use(May Use), Shall_Use(Shall Use), Shall_NOT_Use(Shall not Use) May_Use, Shall_Use, Shall_NOT_Use None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
HSN HSN BSC6900 ADD GCELLMAGRP(Optional) Hopping sequence number (HSN), indicating 64 types of frequency hopping sequences. If this parameter is set to 0, the frequency hopping is performed in sequence.If this parameter is set to a value from 1 to 63, the frequency hopping is performed in a pseudo-random manner. GBFD-113701Frequency Hopping (RF hopping, baseband hopping) Interval Type 0~63 0~63 None None None Cell None Read & Write Y Cell Less than 1 minute HSNs are optional for the cells with frequency hopping enabled. The cells in the same frequency group must use different HSNs. The HSNs of all the channels in a cell must be the same.
HSN HEAD Slot No. BSC6900 ADD BTSRXUCHAIN(Mandatory) Number of the slot where the head board of the RXU chain or ring is located. The slot No. is unique in the same BTS. GBFD-111202O&M of BTS Interval Type 0~23 0~23 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
HSNSW HSN Modification Switch BSC6900 ADD GCELL(Optional) Whether dynamic use of HSNs is enabled. If the functions of frequency hopping and Flex MAIO are enabled in a cell and the value of this parameter is ON, adjacent-channel interference between channels can be reduced. GBFD-117001Flex MAIO Enumeration Type OFF(Off), ON(On) OFF, ON None OFF OFF Cell This parameter is valid when "FHMODE" in the "SET GCELLHOPTP" command is not set to NO_FH. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
HSRN Head Subrack No. BSC6900 ADD BTSRXUCHAIN(Mandatory) Number of the subrack where the head board of the RXU chain or ring is located. The subrack No. is unique in the same BTS. GBFD-111202O&M of BTS Interval Type 0~254 0~254 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
HT Hop Type BSC6900 ADD BTSBFD(Mandatory) Bidirectional Forwarding Detection Hop Type. GBFD-118609IP Fault Detection Based on BFD Enumeration Type SBFD(SINGLE_HOP), MBFD(MULTI_HOP) SBFD, MBFD None None None Current BFD session None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
HTCP High Temperature Critical Point BSC6900 SET BTSDHEUBP(Optional) If the ambient temperature is higher than "High Temperature Critical Point", the temperature control system controls the difference between the inlet and outlet temperatures.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. MRFD-210304Faulty Management Interval Type -99~70 -99~70 degree Celsius None 40 BTS The value of this parameter must be greater than "Low Temperature Critical Point". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
HTDO High Temperature Delta Tout BSC6900 SET BTSDHEUBP(Optional) If the outlet temperature is higher than "High Temperature Critical Point" and the difference between the outlet temperature and ambient temperature reaches the value of this parameter, the temperature control system controls the difference between the inlet and outlet temperatures.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. MRFD-210304Faulty Management Interval Type 0~30 0~30 degree Celsius None 13 BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
HTSDF High Temperature Shutdown Flag BSC6900 SET BTSAPMUBP(Optional) Whether to enable battery power-off against high temperature. MRFD-210304Faulty Management Enumeration Type DISABLE(DISABLE), ENABLE(ENABLE) DISABLE, ENABLE None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
HUBKGPRIPATH HSUPA background primary path BSC6900 ADD TRMMAP(Optional) HSUPA background service bearer primary path None None Enumeration Type CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF None None When the interface type is Iub, transmission type is ATM, the parameter is UBR; transimssion type is dual stack or IP, the parameter is AF13; transimssion type is dual stack or Hybird IP, the parameter is LQAF13.When the interface type is Iur, transmission type is ATM, the parameter is UBR; transimssion type is IP, the parameter is AF13. BSC6900When the value of "ITFT" in "ADD TRMMAP" is set to IUB or IUR, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node configured with the TRMMAP. After the successful modification, it is valid in the case of the new access of a subscriber and the bandwidth modification of an existing subscriber.
HUBKGSECPATH HSUPA background secondary path BSC6900 ADD TRMMAP(Optional) HSUPA background service bearer secondary path None None Enumeration Type CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF, NULL CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF, NULL None None When the interface type is Iub, transmission type is ATM or IP, the parameter is NULL; transimssion type is dual stack, the parameter is UBR; transimssion type is Hybird IP, the parameter is AF13.When the interface type is Iur, transmission type is ATM or IP, the parameter is NULL. BSC6900When the value of "ITFT" in "ADD TRMMAP" is set to IUB or IUR, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node configured with the TRMMAP. After the successful modification, it is valid in the case of the new access of a subscriber and the bandwidth modification of an existing subscriber.
HUBKGUL UMTS HSUPA background service uplink factor BSC6900 ADD TRMFACTOR(Optional) WCDMA HSUPA background service uplink factor None None Interval Type 0~100 0~100 per cent 100 100 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node that is configured with the factor table. After the successful modification, the parameter takes effect in the following two cases:1. New access subscriber. 2. Bandwidth modification of the existing subscriber
HUCONVPRIPATH HSUPA conversational primary path BSC6900 ADD TRMMAP(Optional) HSUPA conversational service primary path None None Enumeration Type CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF None None When the interface type is Iub, transmission type is ATM or dual stack, the parameter is RT_VBR; transimssion type is IP or Hybird IP, the parameter is AF33.When the interface type is Iur, transmission type is ATM, the parameter is RT_VBR; transimssion type is IP, the parameter is AF43. BSC6900When the value of "ITFT" in "ADD TRMMAP" is set to IUB or IUR, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node configured with the TRMMAP. After the successful modification, it is valid in the case of the new access of a subscriber and the bandwidth modification of an existing subscriber.
HUCONVSECPATH HSUPA conversational secondary path BSC6900 ADD TRMMAP(Optional) HSUPA conversational service secondary path None None Enumeration Type CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF, NULL CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF, NULL None None When the interface type is Iub, transmission type is ATM or IP, the parameter is NULL; transimssion type is dual stack, the parameter is AF43; transimssion type is Hybird IP, the parameter is LQAF33.When the interface type is Iur, transmission type is ATM or IP, the parameter is NULL. BSC6900When the value of "ITFT" in "ADD TRMMAP" is set to IUB or IUR, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node configured with the TRMMAP. After the successful modification, it is valid in the case of the new access of a subscriber and the bandwidth modification of an existing subscriber.
HUCONVUL UMTS HSUPA conversational service uplink factor BSC6900 ADD TRMFACTOR(Optional) WCDMA HSUPA conversational service uplink factor None None Interval Type 0~100 0~100 per cent 70 70 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node that is configured with the factor table. After the successful modification, the parameter takes effect in the following two cases:1. New access subscriber. 2. Bandwidth modification of the existing subscriber
HUINTERUL UMTS HSUPA interactive service uplink factor BSC6900 ADD TRMFACTOR(Optional) WCDMA HSUPA interactive service uplink factor None None Interval Type 0~100 0~100 per cent 100 100 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node that is configured with the factor table. After the successful modification, the parameter takes effect in the following two cases:1. New access subscriber. 2. Bandwidth modification of the existing subscriber
HUINTHGHPRIPATH HSUPA high PRI interactive primary path BSC6900 ADD TRMMAP(Optional) HSUPA high PRI interactive primary path None None Enumeration Type CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF None None When the interface type is Iub, transmission type is ATM, the parameter is UBR; transimssion type is dual stack or IP, the parameter is AF23; transimssion type is dual stack or Hybird IP, the parameter is LQAF23.When the interface type is Iur, transmission type is ATM, the parameter is UBR; transimssion type is IP, the parameter is AF23. BSC6900When the value of "ITFT" in "ADD TRMMAP" is set to IUB or IUR, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node configured with the TRMMAP. After the successful modification, it is valid in the case of the new access of a subscriber and the bandwidth modification of an existing subscriber.
HUINTHGHSECPATH HSUPA high PRI interactive secondary path BSC6900 ADD TRMMAP(Optional) HSUPA high PRI interactive secondary path None None Enumeration Type CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF, NULL CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF, NULL None None When the interface type is Iub, transmission type is ATM or IP, the parameter is NULL; transimssion type is dual stack, the parameter is UBR; transimssion type is Hybird IP, the parameter is AF23.When the interface type is Iur, transmission type is ATM or IP, the parameter is NULL. BSC6900When the value of "ITFT" in "ADD TRMMAP" is set to IUB or IUR, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node configured with the TRMMAP. After the successful modification, it is valid in the case of the new access of a subscriber and the bandwidth modification of an existing subscriber.
HUINTLOWPRIPATH HSUPA low PRI interactive primary path BSC6900 ADD TRMMAP(Optional) HSUPA low PRI interactive primary path None None Enumeration Type CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF None None When the interface type is Iub, transmission type is ATM, the parameter is UBR; transimssion type is dual stack or IP, the parameter is AF23; transimssion type is dual stack or Hybird IP, the parameter is LQAF23.When the interface type is Iur, transmission type is ATM, the parameter is UBR; transimssion type is IP, the parameter is AF23. BSC6900When the value of "ITFT" in "ADD TRMMAP" is set to IUB or IUR, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node configured with the TRMMAP. After the successful modification, it is valid in the case of the new access of a subscriber and the bandwidth modification of an existing subscriber.
HUINTLOWSECPATH HSUPA low PRI interactive secondary path BSC6900 ADD TRMMAP(Optional) HSUPA low PRI interactive secondary path None None Enumeration Type CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF, NULL CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF, NULL None None When the interface type is Iub, transmission type is ATM or IP, the parameter is NULL; transimssion type is dual stack, the parameter is UBR; transimssion type is Hybird IP, the parameter is AF23.When the interface type is Iur, transmission type is ATM or IP, the parameter is NULL. BSC6900When the value of "ITFT" in "ADD TRMMAP" is set to IUB or IUR, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node configured with the TRMMAP. After the successful modification, it is valid in the case of the new access of a subscriber and the bandwidth modification of an existing subscriber.
HUINTMIDPRIPATH HSUPA middle PRI interactive primary path BSC6900 ADD TRMMAP(Optional) HSUPA middle PRI interactive primary path None None Enumeration Type CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF None None When the interface type is Iub, transmission type is ATM, the parameter is UBR; transimssion type is dual stack or IP, the parameter is AF23; transimssion type is dual stack or Hybird IP, the parameter is LQAF23.When the interface type is Iur, transmission type is ATM, the parameter is UBR; transimssion type is IP, the parameter is AF23. BSC6900When the value of "ITFT" in "ADD TRMMAP" is set to IUB or IUR, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node configured with the TRMMAP. After the successful modification, it is valid in the case of the new access of a subscriber and the bandwidth modification of an existing subscriber.
HUINTMIDSECPATH HSUPA middle PRI interactive secondary path BSC6900 ADD TRMMAP(Optional) HSUPA middle PRI interactive secondary path None None Enumeration Type CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF, NULL CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF, NULL None None When the interface type is Iub, transmission type is ATM or IP, the parameter is NULL; transimssion type is dual stack, the parameter is UBR; transimssion type is Hybird IP, the parameter is AF23.When the interface type is Iur, transmission type is ATM or IP, the parameter is NULL. BSC6900When the value of "ITFT" in "ADD TRMMAP" is set to IUB or IUR, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node configured with the TRMMAP. After the successful modification, it is valid in the case of the new access of a subscriber and the bandwidth modification of an existing subscriber.
HUM_MASK Enable Humidity Alarm Reporting BSC6900 ADD EMU(Optional) Humidity alarm switch MRFD-210304Faulty Management Enumeration Type CLOSE(Close), OPEN(Open) CLOSE, OPEN None OPEN None Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
HUM_THD_HIGH Upper Limit of Humidity Alarm BSC6900 ADD EMU(Optional) Upper limit of humidity. When the humidity exceeds the upper limit, a humidity alarm is reported. MRFD-210304Faulty Management String Type None 1~9 characters per cent 80 None Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
HUM_THD_LOW Lower Limit of Humidity Alarm BSC6900 ADD EMU(Optional) Lower limit of humidity. When the humidity is lower than the lower limit, a humidity alarm is reported. MRFD-210304Faulty Management String Type None 1~9 characters per cent 10 None Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
HUMALAMRTHRESHOLDH Upper Threshold of Humidity Alarm BSC6900 SET BTSAPMUBP(Optional) When the ambient humidity of the APMU is greater than the value of this parameter, the BTS reports an overhigh ambient humidity alarm.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. MRFD-210304Faulty Management Interval Type 0~1000 0~100 (step: 0.1) None None If "APMU Board Type" is "SC48200", the recommended value is "900". For other types of APMU boards, the recommended value is "1000". BTS The value of this parameter must be greater than "Lower Threshold of Humidity Alarm". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
HUMALAMRTHRESHOLDH Upper Threshold of Humidity Alarm BSC6900 SET BTSDPMUBP(Optional) When the ambient humidity is greater than the value of this parameter, the BTS reports an overhigh ambient humidity alarm.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. MRFD-210304Faulty Management Interval Type 0~1000 0~100 (step: 0.1) None None 800 BTS The value of this parameter must be greater than "Lower Threshold of Humidity Alarm". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
HUMALAMRTHRESHOLDL Lower Threshold of Humidity Alarm BSC6900 SET BTSAPMUBP(Optional) When the ambient humidity of the APMU is less than the value of this parameter, the BTS reports an overlow ambient humidity alarm.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. MRFD-210304Faulty Management Interval Type 0~1000 0~100 (step: 0.1) None None If "APMU Board Type" is "SC48200", the recommended value is "100". For other types of APMU boards, the recommended value is "0". BTS The value of this parameter must be smaller than "Upper Threshold of Humidity Alarm". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
HUMALAMRTHRESHOLDL Lower Threshold of Humidity Alarm BSC6900 SET BTSDPMUBP(Optional) When the ambient humidity is less than the value of this parameter, the BTS reports an overlow ambient humidity alarm.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. MRFD-210304Faulty Management Interval Type 0~1000 0~100 (step: 0.1) None None 100 BTS The value of this parameter must be smaller than "Upper Threshold of Humidity Alarm". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
HUSIPPRIPATH HSUPA IMS Signal primary path BSC6900 ADD TRMMAP(Optional) HSUPA IMS signaling bearer primary path None None Enumeration Type CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF None None When the interface type is Iub, transmission type is ATM or dual stack, the parameter is RT_VBR; transimssion type is IP or Hybird IP, the parameter is EF.When the interface type is Iur, transmission type is ATM, the parameter is RT_VBR; transimssion type is IP, the parameter is EF. BSC6900When the value of "ITFT" in "ADD TRMMAP" is set to IUB or IUR, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node configured with the TRMMAP. After the successful modification, it is valid in the case of the new access of a subscriber and the bandwidth modification of an existing subscriber.
HUSIPSECPATH HSUPA IMS Signal secondary path BSC6900 ADD TRMMAP(Optional) HSUPA IMS signaling bearer secondary path None None Enumeration Type CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF, NULL CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF, NULL None None When the interface type is Iub, transmission type is ATM or IP, the parameter is NULL; transimssion type is dual stack, the parameter is EF; transimssion type is Hybird IP, the parameter is LQEF.When the interface type is Iur, transmission type is ATM or IP, the parameter is NULL. BSC6900When the value of "ITFT" in "ADD TRMMAP" is set to IUB or IUR, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node configured with the TRMMAP. After the successful modification, it is valid in the case of the new access of a subscriber and the bandwidth modification of an existing subscriber.
HUSIPUL UMTS HSUPA IMS signal uplink factor BSC6900 ADD TRMFACTOR(Optional) WCDMA HSUPA IMS signaling uplink factor None None Interval Type 0~100 0~100 per cent 15 15 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node that is configured with the factor table. After the successful modification, the parameter takes effect in the following two cases:1. New access subscriber. 2. Bandwidth modification of the existing subscriber
HUSRBPRIPATH HSUPA Signal primary path BSC6900 ADD TRMMAP(Optional) HSUPA signaling bearer primary path None None Enumeration Type CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF None None When the interface type is Iub, transmission type is ATM or dual stack, the parameter is RT_VBR; transimssion type is IP or Hybird IP, the parameter is EF.When the interface type is Iur, transmission type is ATM, the parameter is RT_VBR; transimssion type is IP, the parameter is EF. BSC6900When the value of "ITFT" in "ADD TRMMAP" is set to IUB or IUR, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node configured with the TRMMAP. After the successful modification, it is valid in the case of the new access of a subscriber and the bandwidth modification of an existing subscriber.
HUSRBSECPATH HSUPA Signal secondary path BSC6900 ADD TRMMAP(Optional) HSUPA signaling bearer secondary path None None Enumeration Type CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF, NULL CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF, NULL None None When the interface type is Iub, transmission type is ATM or IP, the parameter is NULL; transimssion type is dual stack, the parameter is EF; transimssion type is Hybird IP, the parameter is LQEF.When the interface type is Iur, transmission type is ATM or IP, the parameter is NULL. BSC6900When the value of "ITFT" in "ADD TRMMAP" is set to IUB or IUR, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node configured with the TRMMAP. After the successful modification, it is valid in the case of the new access of a subscriber and the bandwidth modification of an existing subscriber.
HUSRBUL UMTS HSUPA signal uplink factor BSC6900 ADD TRMFACTOR(Optional) WCDMA HSUPA signaling uplink factor None None Interval Type 0~100 0~100 per cent 50 50 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node that is configured with the factor table. After the successful modification, the parameter takes effect in the following two cases:1. New access subscriber. 2. Bandwidth modification of the existing subscriber
HUSTRMPRIPATH HSUPA streaming primary path BSC6900 ADD TRMMAP(Optional) HSUPA streaming service bearer primary path None None Enumeration Type CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF None None When the interface type is Iub, transmission type is ATM or dual stack, the parameter is RT_VBR; transimssion type is IP or Hybird IP, the parameter is AF33.When the interface type is Iur, transmission type is ATM, the parameter is RT_VBR; transimssion type is IP, the parameter is AF43. BSC6900When the value of "ITFT" in "ADD TRMMAP" is set to IUB or IUR, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node configured with the TRMMAP. After the successful modification, it is valid in the case of the new access of a subscriber and the bandwidth modification of an existing subscriber.
HUSTRMSECPATH HSUPA streaming secondary path BSC6900 ADD TRMMAP(Optional) HSUPA streaming service bearer secondary path None None Enumeration Type CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF, NULL CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF, NULL None None When the interface type is Iub, transmission type is ATM or IP, the parameter is NULL; transimssion type is dual stack, the parameter is AF43; transimssion type is Hybird IP, the parameter is LQAF33.When the interface type is Iur, transmission type is ATM or IP, the parameter is NULL. BSC6900When the value of "ITFT" in "ADD TRMMAP" is set to IUB or IUR, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node configured with the TRMMAP. After the successful modification, it is valid in the case of the new access of a subscriber and the bandwidth modification of an existing subscriber.
HUSTRMUL UMTS HSUPA streaming service uplink factor BSC6900 ADD TRMFACTOR(Optional) WCDMA HSUPA streaming service uplink factor None None Interval Type 0~100 0~100 per cent 100 100 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node that is configured with the factor table. After the successful modification, the parameter takes effect in the following two cases:1. New access subscriber. 2. Bandwidth modification of the existing subscriber
HUVOICEPRIPATH HSUPA Voice primary path BSC6900 ADD TRMMAP(Optional) HSUPA voice service bearer primary path None None Enumeration Type CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF None None When the interface type is Iub, transmission type is ATM or dual stack, the parameter is RT_VBR; transimssion type is IP or Hybird IP, the parameter is EF.When the interface type is Iur, transmission type is ATM, the parameter is RT_VBR; transimssion type is IP, the parameter is EF. BSC6900When the value of "ITFT" in "ADD TRMMAP" is set to IUB or IUR, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node configured with the TRMMAP. After the successful modification, it is valid in the case of the new access of a subscriber and the bandwidth modification of an existing subscriber.
HUVOICESECPATH HSUPA Voice secondary path BSC6900 ADD TRMMAP(Optional) HSUPA voice service bearer secondary path None None Enumeration Type CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF, NULL CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF, NULL None None When the interface type is Iub, transmission type is ATM or IP, the parameter is NULL; transimssion type is dual stack, the parameter is EF; transimssion type is Hybird IP, the parameter is LQEF.When the interface type is Iur, transmission type is ATM or IP, the parameter is NULL. BSC6900When the value of "ITFT" in "ADD TRMMAP" is set to IUB or IUR, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node configured with the TRMMAP. After the successful modification, it is valid in the case of the new access of a subscriber and the bandwidth modification of an existing subscriber.
HUVOICEUL UMTS HSUPA voice service uplink factor BSC6900 ADD TRMFACTOR(Optional) WCDMA HSUPA voice service uplink factor None None Interval Type 0~100 0~100 per cent 70 70 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node that is configured with the factor table. After the successful modification, the parameter takes effect in the following two cases:1. New access subscriber. 2. Bandwidth modification of the existing subscriber
HYSON Hysteresis for On BSC6900 SET BTSAIRCON(Optional) Delay for which the BTS waits to switch on the air conditioner GBFD-111202O&M of BTS Interval Type 1~30 1~30 min None 15 BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter is supported only by the BTS3012A and BTS3006A.
IARXTMR Inactive RX timer BSC6900 SET SCCPTMR(Optional) This timer is started after a connection is established successfully. If a detection message is not received when this timer expires, the connection will be released. None None Interval Type 180~1260 180~1260 s None 720 SCCP None Read & Write N (No impact on the UE in idle mode) Not involved Not involved For details of the timer, see ITU-T Q.714. The modification is not recommended.
IASUDURAT Duration BSC6900 STR TRANSPERFTST(Mandatory) Duration in IASU mode GBFD-111207BTS Test Function Interval Type 1~60 1~60 min None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IASUPORT Port No. BSC6900 STR TRANSPERFTST(Mandatory) Port number in IASU mode. For the BTS3002C, the port number cannot be set to "E1PORT3". GBFD-118601Abis over IP Enumeration Type E1PORT0(E1 PORT0), E1PORT1(E1 PORT1), E1PORT2(E1 PORT2), E1PORT3(E1 PORT3), OPTICALPORT0(OPTICAL PORT0), OPTICALPORT1(OPTICAL PORT1) E1PORT0, E1PORT1, E1PORT2, E1PORT3, OPTICALPORT0, OPTICALPORT1 None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IASUSLCTTMU TMU Type BSC6900 STR TRANSPERFTST(Mandatory) Type of the TMU in IASU mode GBFD-111202O&M of BTS Enumeration Type MAINDOMU(MAIN DOMU), SLAVEDOMU1(SLAVE DOMU1), SLAVEDOMU2(SLAVE DOMU2) MAINDOMU, SLAVEDOMU1, SLAVEDOMU2 None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IATXTMR Inactive TX timer BSC6900 SET SCCPTMR(Optional) This timer is started after a connection is established successfully. When this timer expires, a detection message will be sent to the peer end. None None Interval Type 60~600 60~600 s None 90 SCCP None Read & Write N (No impact on the UE in idle mode) Not involved Not involved For details of the timer, see ITU-T Q.714. The modification is not recommended.
IBCAAFRSOFTBLKTHRD IBCA AMR FR Soft Block Threshold BSC6900 SET GCELLCHMGAD(Optional) Minimum C/I ratio that IBCA AMR FR services allow. An idle channel can be assigned to such a service only when the C/I ratio of the idle channel is greater than this threshold. In addition, a new call associated with such a service can be established only when the call does not decrease the C/I ratio of the established calls to a value less than this threshold. GBFD-117002IBCA (Interference Based Channel Allocation) Interval Type 0~23 0~23 dB None 4 Cell This parameter is valid only when "IBCASOFTBLKSWITCH" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IBCAAHRSOFTBLKTHRD IBCA AMR HR Soft Block Threshold BSC6900 SET GCELLCHMGAD(Optional) Minimum C/I ratio that IBCA AMR HR services allow. An idle channel can be assigned to such a service only when the C/I ratio of the idle channel is greater than this threshold. In addition, a new call associated with such a service can be established only when the call does not decrease the C/I ratio of the established calls to a value less than this threshold. GBFD-117002IBCA (Interference Based Channel Allocation) Interval Type 0~23 0~23 dB None 10 Cell This parameter is valid only when "IBCASOFTBLKSWITCH" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IBCAALLOWED IBCA Allowed BSC6900 SET GCELLCHMGAD(Optional) Whether to enable the IBCA algorithm GBFD-117002IBCA (Interference Based Channel Allocation) Enumeration Type NO(No), YES(Yes)NO, YES None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IBCAASSWAITMEASURERPTTIME IBCA Assign Waiting Mr Time BSC6900 SET GCELLCHMGAD(Optional) Length of the timer for a new call to wait for the measurement report (MR) on the signaling channel when dynamic measurement of the BA2 list is enabled during assignment. If this parameter is set to 0, dynamic measurement of the BA2 list is not enabled during assignment. GBFD-117002IBCA (Interference Based Channel Allocation) Interval Type 0~20 0~20, Step: 0.5 s None 4 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IBCACALLINFOFILTERLEN IBCA Call Information Filter BSC6900 SET GCELLCHMGAD(Optional) Number of measurement reports sampled for averaging path loss. A single measurement report may not reflect the actual network situations accurately. Therefore, the BSC needs to average the measured values in several successive measurement reports to reflect the radio environment. GBFD-117002IBCA (Interference Based Channel Allocation) Interval Type 1~4 1~4, step:480 for TCH and 470 for SDCCH ms None 4 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IBCACALLSOFTBLOCKTHOFFSET IBCA Set-up Call Soft Block Thres Offset BSC6900 SET GCELLCHMGAD(Optional) When the IBCA algorithm is enabled, this parameter is used to calculate the actual soft blocking threshold of an existing call. The formula is as follows: Actual soft blocking threshold of an existing call = Configured soft blocking threshold of an existing call - IBCA Set-up Call Soft Block Thres Offset. None None Interval Type 0~14 0~14 dB None 0 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IBCACALLTARGETCIROFFSET Target CIR Offset of IBCA Set-up Call BSC6900 SET GCELLCHMGAD(Optional) When the IBCA algorithm is enabled, this parameter is used to calculate the target CIR of an existing call. The formula is as follows: Target CIR of an existing call = Target CIR in use + Target CIR Offset of IBCA Set-Up Call. None None Interval Type 0~14 0~14 dB None 4 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IBCADLPATHLOSSOFF IBCA Downlink Path Loss Offset BSC6900 SET GCELLCHMGAD(Optional) Difference between uplink and downlink path losses, which is used to estimate the downlink path loss of a call when the downlink path loss cannot be computed directly according to a measurement report. This parameter is configured according to the combined loss and hierarchical dual-antenna gain (3 dB) of the BTS."IBCA Downlink Path Loss Offset" = combined loss of BTS + hierarchical dual-antenna gain of BTS (3 dB) GBFD-117002IBCA (Interference Based Channel Allocation) Interval Type 0~63 0~63 dB None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IBCADYNCMEASURENCELLALLOWED IBCA Dyn Measure Neighbour Cell Flag BSC6900 ADD G2GNCELL(Optional) Whether to measure the IBCA neighbor cells of the serving cell dynamically. If the dynamic measurement is enabled, when a call uses a channel, the BSC sends the SACCH Modify message to modify the frequencies in the BA2 table in System Information 5, 5bis, and 5ter to the frequencies at which the IBCA neighbor cells operate. Thus, the call measures and reports only these frequencies to the BSC. GBFD-117002IBCA (Interference Based Channel Allocation) Enumeration Type NO(No), YES(Yes)NO, YES None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IBCAEHOASSWAITMEASURERPTTIME IBCA Urgent HO Waiting Mr Time BSC6900 SET GCELLCHMGAD(Optional) Length of the timer for a call to measure the path loss in the neighboring cell with strong interference of the target cell. The call to be handed over needs to measure the path loss before initiating the handover to the target cell when dynamic measurement of the BA2 list is enabled during the emergency handover. When this parameter is set to 0, dynamic measurement of the BA2 list is not enabled in the emergency handover, and the parameter "Wait Time for Valid MRs in IBCA HO" is invalid. GBFD-117002IBCA (Interference Based Channel Allocation) Interval Type 0~20 0~20, Step: 0.5 s None 0 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IBCAFLEXTSCALLOWED IBCA Flexible TSC Allowed BSC6900 SET GCELLCHMGAD(Optional) Whether the IBCA flexible TSC function is enabled. When this parameter is set to NO, the flexible TSC function is disabled and the configured TSC is used. When the BTS supports Flex TSC and this parameter is set to YES, the flexible TSC function is enabled. GBFD-117002IBCA (Interference Based Channel Allocation) Enumeration Type OFF(Not Allowed), ON(Allowed) OFF, ON None None OFF Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IBCAFORCEDBTSSYNCALLOWED IBCA Forced BTS Synchronization Allowed BSC6900 SET GCELLCHMGAD(Optional) Whether the IBCA forced BTS synchronization is allowed. When this parameter is set to YES, the synchronization procedure is performed even though the BTSs are insynchronous. When this parameter is set to NO, the existing procedure, either the synchronization procedure or the out-of-synchronization procedure, is performed as required. Note that the synchronization status of the IBCA neighboring cells is determined by the internal software parameters of the IBCA neighboring cells, that is, if this parameter in IBCA neighboring cells is set to YES, the IBCA neighboring cells are considered to be always synchronous; otherwise, the IBCA neighboring cells are considered to be out of synchronization. GBFD-117002IBCA (Interference Based Channel Allocation) Enumeration Type OFF(Not Allowed), ON(Allowed) OFF, ON None None OFF Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IBCAFRSOFTBLKTHRD IBCA FR/EFR Soft Block Threshold BSC6900 SET GCELLCHMGAD(Optional) Minimum C/I ratio that IBCA FR/EFR services allow. An idle channel can be assigned to such a service only when the C/I ratio of the idle channel is greater than this threshold. In addition, a new call associated with such a service can be established only when the call does not decrease the C/I ratio of the established calls to a value less than this threshold. GBFD-117002IBCA (Interference Based Channel Allocation) Interval Type 0~23 0~23 dB None 10 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IBCAHOASSWAITMEASURERPTTIME IBCA HO Waiting Effective Mr Time BSC6900 SET GCELLCHMGAD(Optional) Length of the timer for a call to wait for other valid MRs after receiving the first valid MR of the target cell if dynamic measurement of the BA2 list is enabled during handover. When this parameter is set to 0, the call does not wait for other MRs after receiving the first MR of the target cell. GBFD-117002IBCA (Interference Based Channel Allocation) Interval Type 0~20 0~20, Step: 0.5 s None 2 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IBCAHRSOFTBLKTHRD IBCA HR Soft Block Threshold BSC6900 SET GCELLCHMGAD(Optional) Minimum C/I ratio that IBCA HR services allow. An idle channel can be assigned to such a service only when the C/I ratio of the idle channel is greater than this threshold. In addition, a new call associated with such a service can be established only when the call does not decrease the C/I ratio of the established calls to a value less than this threshold. GBFD-117002IBCA (Interference Based Channel Allocation) Interval Type 0~23 0~23 dB None 13 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IBCAICDMRELEVOFFSET IBCA ICDM Initial Level Offset BSC6900 SET GCELLCHMGAD(Optional) In the ICDM matrix algorithm, the signal strength (0-63) is divided into 10 levels. The signal strength that is smaller than or equal to the value of this parameter is at the initial level. None None Interval Type 0~31 0~31 dB None 10 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IBCAICDMSWITCH IBCA ICDM Switch BSC6900 SET GCELLCHMGAD(Optional) Whether to enable the ICDM algorithm for the cell. The ICDM algorithm helps to improve the precision in estimating the path loss of an IBCA neighbor cell and to increase the efficiency of the IBCA algorithm. GBFD-117002IBCA (Interference Based Channel Allocation) Enumeration Type NO(No), YES(Yes)NO, YES None None YES Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IBCAINBSCINFORPTPRD IBCA Info Report Period Within BSC BSC6900 SET OTHSOFTPARA(Optional) Period of information exchange between the BSC boards. The information helps to estimate the C/I ratio for the IBCA algorithm. GBFD-117002IBCA (Interference Based Channel Allocation) Interval Type 2~600 2~600 s None 4 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IBCAINITPCRXLEVDLOFFSET IBCA Init. Power Control RexLevDL Offset BSC6900 SET GCELLCHMGAD(Optional) Adds a specified offset to the downlink target receive level when power control algorithm III is used to calculate the initial transmit power of a BTS in the IBCA function GBFD-117002IBCA (Interference Based Channel Allocation) Interval Type 0~63 0~63 dB None 0 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IBCAINITPCRXLEVULOFFSET IBCA Init. Power Control RexLevUL Offset BSC6900 SET GCELLCHMGAD(Optional) Adds a specified offset to the uplink target receive level when power control algorithm III is used to calculate the initial transmit power of an MS in the IBCA function GBFD-117002IBCA (Interference Based Channel Allocation) Interval Type 0~63 0~63 dB None 0 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IBCAINITPCRXQUALDLOFFSET IBCA Init. Pwr Ctrl Rx Qual DL Offset BSC6900 SET GCELLCHMGAD(Optional) Adds a specified offset to the downlink target receive quality when power control algorithm III is used to calculate the initial transmit power of a BTS in the IBCA function GBFD-117002IBCA (Interference Based Channel Allocation) Interval Type 0~22 0~22 dB None 0 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IBCAINITPCRXQUALULOFFSET IBCA Init. Pwr Ctrl Rx Qual UL Offset BSC6900 SET GCELLCHMGAD(Optional) Adds a specified offset to the uplink target receive quality when power control algorithm III is used to calculate the initial transmit power of an MS in the IBCA function GBFD-117002IBCA (Interference Based Channel Allocation) Interval Type 0~22 0~22 dB None 0 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IBCAIUOPATHLOSSOFF IBCA IUO Path Loss Offset BSC6900 SET GCELLCHMGAD(Optional) In an IUO cell (or a CoBCCH cell), the path loss of an MS to the serving cell or a neighboring cell measured on the underlay is used together with this parameter to estimate the path loss on the overlay. IUO path loss compensation = Combiner insert loss difference + Path loss difference due to the use of different antennas + Path loss difference due to different frequency selectivity. This value is calculated based on the IUO level values measured by field engineers. When different antennas are used by the overlay and underlay, the level must be measured at multiple locations. GBFD-117002IBCA (Interference Based Channel Allocation) Interval Type 0~63 0~63 dB None 4 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IBCAMAIOUSMTD IBCA MAIO Using Method BSC6900 SET GCELLCHMGAD(Optional) Determines the MAIO selection method for each timeslot. The Optimal MAIO policy selects the optimal MAIO being evaluated, while the Random MAIO policy randomly selects a MAIO out of qualified MAIOs. GBFD-117002IBCA (Interference Based Channel Allocation) Enumeration Type 0(Max. optimized MAIO), 1(Randomization MAIO) 0, 1 None None 0 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IBCAMAXINTFSRCNUM IBCA Max. Interference Source Num. BSC6900 SET GCELLCHMGAD(Optional) The IBCA interference evaluation process only considers the interference of the strongest N existing calls on the newly-established call being evaluated. This parameter corresponds to the above-mentioned N. GBFD-117002IBCA (Interference Based Channel Allocation) Interval Type 5~40 5~40 None None 20 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IBCANCELLFLAG IBCA Neighbor Cell Flag BSC6900 ADD G2GNCELL(Optional) Indicates whether this neighboring cell is the IBCA neighboring cell of the serving cell. That is, when a cell is configured as the neighboring cell of the serving cell, whether the IBCA algorithm considers the interference between the serving cell and the neighboring cell. GBFD-117002IBCA (Interference Based Channel Allocation) Enumeration Type NO(No), YES(Yes)NO, YES None None NO Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The parameter IBCA Allowed of the serving cell and the neighbor cell should be set to Yes before the configuration of this parameter.
IBCANCELLPATHLOSSESTIMATE IBCA Pathloss Est of Non. MR Ncell BSC6900 SET GCELLCHMGAD(Optional) Estimates the receive level of the unmeasured IBCA neighboring cells. When a consecutive "IBCA Non Measurement Ncell Stat. Num" measurement reports cover less than six neighboring cells (or the number of the reported neighboring cells is smaller than that of the actually configured neighboring cells), this parameter is used to estimate the receive level of the unmeasured IBCA neighboring cells. The estimated value is "IBCA Pathloss Est of Non. MR Ncell". Otherwise, the signal strength of the unmeasured IBCA neighboring cells is the signal strength of the measured neighboring cells (including non-IBCA neighboring cells) subtracted by "IBCA RxLev Offset". GBFD-117002IBCA (Interference Based Channel Allocation) Interval Type 0~63 0~63 dB None 0 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IBCANEWCALLCIROFFSET Target CIR Offset of IBCA New Call BSC6900 SET GCELLCHMGAD(Optional) When the IBCA algorithm is enabled, this parameter is used to calculate the target CIR of a new call. The formula is as follows: Target CIR of a new call = Target CIR in use + Target CIR Offset of IBCA New Call None None Interval Type 0~30 0~30 dB None 7 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IBCANHOASSWAITMEASURERPTTIME IBCA Natural HO Waiting Mr Time BSC6900 SET GCELLCHMGAD(Optional) Length of the timer for a call to measure the path loss in the neighboring cell with strong interference of the target cell. The call to be handed over needs to measure the path loss before initiating the handover to the target cell when dynamic measurement of the BA2 list is enabled during the normal handover. When this parameter is set to 0, dynamic measurement of the BA2 list is not enabled in the normal handover, and the parameter "Wait Time for Valid MRs in IBCA HO" is invalid. GBFD-117002IBCA (Interference Based Channel Allocation) Interval Type 0~20 0~20, Step: 0.5 s None 9 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IBCANONMEANCELLSTATNUM IBCA Non Measurement Ncell Stat. Num BSC6900 SET GCELLCHMGAD(Optional) Estimates the receive level of the unmeasured IBCA neighboring cells. When a consecutive "IBCA Non Measurement Ncell Stat. Num" measurement reports cover less than six neighboring cells (or the number of the reported neighboring cells is smaller than that of the actually configured neighboring cells), this parameter is used to estimate the receive level of the unmeasured IBCA neighboring cells. The estimated value is "IBCA Pathloss Est of Non. MR Ncell". Otherwise, the signal strength of the unmeasured IBCA neighboring cells is the signal strength of the measured neighboring cells (including non-IBCA neighboring cells) subtracted by "IBCA RxLev Offset". GBFD-117002IBCA (Interference Based Channel Allocation) Interval Type 0~16 0~16 None None 4 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IBCAOPRREVISEFACTOR Corrected Factor of IBCA Priority BSC6900 SET GCELLCHMGAD(Optional) When the IBCA algorithm is enabled and the HSN is not 0, the IBCA priority and the SDCCH/PDCH priority are divided by this corrected factor respectively to reduce the weight of IBCA priority. In addition, the priority of the interference band is considered. None None Interval Type 0~63 0~63 None None 0 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IBCAOUTBSCINFORPTPRD IBCA Info Report Period Between BSC BSC6900 SET OTHSOFTPARA(Optional) Specifies a period during which the inter-BSC information exchange must be completed. The information is mainly used by IBCA for C/I ratio estimation. GBFD-117002IBCA (Interference Based Channel Allocation) Interval Type 2~600 2~600 s None 8 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IBCAPATHLOSSOFF IBCA Pathloss Offset BSC6900 SET GCELLCHMGAD(Optional) When the path loss of an MS to a neighboring cell cannot be measured based on the existing measurement results, it is estimated based on the path loss of the MS to the serving cell plus the IBCA path loss offset. GBFD-117002IBCA (Interference Based Channel Allocation) Interval Type 0~50 0~50 dB None It is recommended that you set the path loss offset of layer 1 neighboring cells of the serving cell to 15 dB and that of other neighboring cells to 25 dB. Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IBCAPLFILTFACTOR IBCA Path Lose Filter Factor BSC6900 SET GCELLCHMGAD(Optional) Considers the influence of history path loss information during the calculation of the ICDM algorithm path loss. The smaller the filtering coefficient, the smaller the influence of history path loss; on the other hand, the larger the filtering coefficient, the larger the influence of history path loss. GBFD-117002IBCA (Interference Based Channel Allocation) Interval Type 0~10 0~10 None None 6 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IBCARXLEVOFFSET IBCA RxLev Offset BSC6900 ADD G2GNCELL(Optional) Estimates the receive level of the unmeasured IBCA neighboring cells. When a consecutive "IBCA Non Measurement Ncell Stat. Num" measurement reports cover less than six neighboring cells (or the number of the reported neighboring cells is smaller than that of the actually configured neighboring cells), this parameter is used to estimate the receive level of the unmeasured IBCA neighboring cells. The estimated value is "IBCA Pathloss Est of Non. MR Ncell". Otherwise, the signal strength of the unmeasured IBCA neighboring cells is the signal strength of the measured neighboring cells (including non-IBCA neighboring cells) subtracted by "IBCA RxLev Offset". GBFD-117002IBCA (Interference Based Channel Allocation) Interval Type 0~63 0~63 dB None 4 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IBCASCELLPATHLOSS IBCA Service Cell Pathloss BSC6900 SET GCELLCHMGAD(Optional) Use this parameter when the path loss of an MS to serving cells cannot be measured based on the existing measurement results. GBFD-117002IBCA (Interference Based Channel Allocation) Interval Type 0~160 0~160 dB None 110 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IBCASOFTBLKSAICOFF IBCA Soft Block SAIC Offset BSC6900 SET GCELLCHMGAD(Optional) MSs that support SAIC can tolerate a lower carrier-to-interference ratio. This variable indicates the downward adjustment step of the soft blocking threshold of SAIC MSs. GBFD-117002IBCA (Interference Based Channel Allocation) Interval Type 0~23 0~23 dB None 1 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IBCASOFTBLKSWITCH IBCA Soft Block Switch BSC6900 SET GCELLCHMGAD(Optional) Whether to deny the access of a call when none of the MAIO evaluation results meets the C/I ratio requirement of the call during channel assignment. GBFD-117002IBCA (Interference Based Channel Allocation) Enumeration Type NO(No), YES(Yes)NO, YES None None NO Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IBCASUBCHNHANDOVERALLOWED IBCA Sub-Channel Handover Allowed BSC6900 SET GCELLCHMGAD(Optional) Whether the handover of the calls on the single channels is allowed (single channels are the two half-rate sub-channels on a timeslot, in which only one is in the occupied state) when single channels are to be adjusted to a full-rate channel. When this parameter is set to YES, the handover of the calls on the single channels is allowed; if this parameter is set to NO, the handover of the calls on the single channels is not allowed. This parameter is valid only when the IBCA algorithm is enabled and full rate is preferred for the newly established call. GBFD-117002IBCA (Interference Based Channel Allocation) Enumeration Type OFF(Not Allowed), ON(Allowed) OFF, ON None None OFF Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IBCATARGETCIRTHRSH IBCA MAIO Target C/I Threshold BSC6900 SET GCELLCHMGAD(Optional) Whether a MAIO meets the access requirement. When the C/I ratio of a MAIO is higher than this threshold, the MAIO can be assigned to the call being processed. GBFD-117002IBCA (Interference Based Channel Allocation) Interval Type 0~63 0~63 None None 20 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IBCAUSEDIUOSUBLAY IUO IBCA Allowed BSC6900 SET GCELLCHMGAD(Optional) Whether to enable the IBCA algorithm for the overlay and underlay of an IUO cell. GBFD-117002IBCA (Interference Based Channel Allocation) Enumeration Type NO(Disabled in OL and UL subcell), UNDER(Enabled in UL subcell), INNER( Enabled in OL subcell), YES(Enabled in OL and UL subcell) NO, UNDER, INNER, YES None None UNDER Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IBCAUSRDYNCMEASURENCELL IBCA User Dyn Measure Neighbor Cell BSC6900 SET GCELLCHMGAD(Optional) Whether a single IBCA MS can dynamically measure the neighboring cells. When this parameter is set to YES, the neighboring cells where "IBCA Dynamic Measure Neighbor Cell Flag" is set to YES are dynamically measured. Dynamic measurement on neighboring cells is mutually exclusive to directed retry. When this parameter is set to YES, it is recommended that "Direct Retry" be set to NO. GBFD-117002IBCA (Interference Based Channel Allocation) Enumeration Type NO(No), YES(Yes)NO, YES None None NO Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IBCAWAFRSOFTBLKTHRD IBCA WAMR FR Soft Block Threshold BSC6900 SET GCELLCHMGAD(Optional) The lowest C/I ratio that can be tolerated by IBCA WAMR FR. The C/I ratio of an idle channel must be larger than this parameter. Otherwise, it cannot be assigned. In addition, the system does not allow a newly-established call causing the C/I ratio of existing calls to be lower than this parameter. GBFD-117002IBCA (Interference Based Channel Allocation) Interval Type 0~23 0~23 dB None 5 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ICBALLOW ICB Allowed BSC6900 SET GCELLBASICPARA(Optional) This parameter specifies whether to enable the ICB function in the BTS. If this parameter is set to Yes, the TCHs on the same module on the non-BCCH TRXs are preferentially assigned. In this way, the TRXs on the same module on the BCCH are idle and thus the ICB function can be enabled in the BTS. GBFD-111604Intelligent Combiner Bypass Enumeration Type NO(NO), YES(YES), NULL(NULL) NO, YES, NULL None None NO Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ICF Intelligent Control Flag BSC6900 SET BTSAPMUBP(Optional) Whether to enable the intelligent control of the diesel engine. If this parameter is set to ENABLE, the PMU will control the diesel engine automatically according to the settings of the parameters to save the energy. This parameter is set to ENABLE by default. GBFD-111202O&M of BTS Enumeration Type DISABLE(DISABLE), ENABLE(ENABLE) DISABLE, ENABLE None None ENABLE BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ICMPPKGLEN ICMP packet Length BSC6900 ADD IPPATH(Optional) ICMP packet length. It is the total length of the ICMP packet containing the IP header. None None Interval Type 44~1024 44~1024 byte 64 64 IP path When the value of "PATHCHK" in "ADD IPPATH" is set to ENABLED, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved When the network status is poor, the packet length should not be too large. Otherwise, the path state is affected.
ICTHP1DSCP DSCP of PRI.1 INTACT[QoS] BSC6900 SET BSCPSTCDSCPMAP(Optional) DSP corresponding to the interaction service with the THP level of PRIORITY1. GBFD-118603Gb over IP Interval Type 0~63 0~63 None None 22 BSC None Read & Write Not involved Not involved Not involved None
ICTHP2DSCP DSCP of PRI.2 INTACT[QoS] BSC6900 SET BSCPSTCDSCPMAP(Optional) DSP corresponding to the interaction service with the THP level of PRIORITY2. GBFD-118603Gb over IP Interval Type 0~63 0~63 None None 20 BSC None Read & Write Not involved Not involved Not involved None
5/5/2014
Confidential Information of Huawei.
No Spreading without Permission
Page10of42
226347869.xls.ms_office Security Level:
ICTHP3DSCP DSCP of PRI.3 INTACT[QoS] BSC6900 SET BSCPSTCDSCPMAP(Optional) DSP corresponding to the interaction service with the THP level of PRIORITY3. GBFD-118603Gb over IP Interval Type 0~63 0~63 None None 18 BSC None Read & Write Not involved Not involved Not involved None
ID Task ID BSC6900 ADD SCHTSK(Mandatory)SET SCHTSKSW(Optional)ADD SUBTSK(Optional)ADD SUBCMD(Optional) Number of the scheduled task GBFD-111203O&M of BSC Interval Type 1~30 1~30 None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ID Task ID BSC6900 STR SCHTSK(Optional) Number of the scheduled task GBFD-111203O&M of BSC Interval Type 1~30,100~32767 1~30, 100~32767 None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ID Index BSC6900 ADD BTSBRDCAP(Mandatory) Index GBFD-111202O&M of BTS Interval Type 0~65535 0~65535 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
Idle_Code Idle Code BSC6900 SET TCPARA(Optional) This parameter indicates the idle code of the A interface. It is used for the interconnection of the A interfaces. GBFD-118602A over IP Interval Type 0~255 0~255 None None None Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IDLECODE Idle code BSC6900 SET E1T1LOP(Optional) IDLE code None None Interval Type 0~255 0~255 None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IDLESDTHRES Idle SDCCH Threshold N1 BSC6900 SET GCELLCHMGBASIC(Optional) When the number of idle SDCCH channels in a cell is smaller than this parameter, the system searches for available TCHs and transforms them into SDCCH channels. GBFD-113001SDCCH Dynamic Adjustment Interval Type 0~63 0~63 None None 2 Cell This parameter is one of the conditions for the dynamic conversion of the TCHF to the SDCCH.In addition to the condition that the number of idle SDCCHs should be smaller than or equal to "IDLESDTHRES", the following three conditions must be met to trigger the conversion from the TCHF to the SDCCH:1. "SDDYN" in "SET GCELLBASICPARA" is set to YES.2. In the cell, the value of (number of idle TCHFs + number of idle TCHHs/2) is greater than four and is greater than the number of TRXs. Idle TCHFs exist in the cell.3. Number of SDCCHs + 8 < "CELLMAXSD". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IDTYPE Index Type BSC6900 SET BTSEXCURSION(Mandatory)ADD EXTNCELL(Mandatory)SET BSCSYNCOFF(Mandatory)SET BTSAISS(Mandatory) Index type. GBFD-111202O&M of BTS Enumeration Type BYIDX(By Index), BYNAME(By Name) BYIDX, BYNAME None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None.
IDTYPE BTS Index Type BSC6900 SET BTSABISPRIMAP(Mandatory)ADD BTSESN(Mandatory) BTS index typeGBFD-111202O&M of BTS Enumeration Type BYNAME(By Name), BYID(By Index) BYNAME, BYID None None None BSC6900None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
IDTYPE Index Type BSC6900 ADD GCELLFREQ(Mandatory)ADD GCELLHOPANTGRP(Mandatory)ADD GCELLMAGRP(Mandatory)ADD GCELLOSPMAP(Mandatory)SET GCELLAMRQUL(Mandatory)SET GCELLBASICPARA(Mandatory)SET GCELLCCACCESS(Mandatory)SET GCELLCCAD(Mandatory)SET GCELLCCTMR(Mandatory)SET GCELLCCUTRANSYS(Mandatory)SET GCELLEXTMSRPARA(Mandatory)SET GCELLGSMR(Mandatory)SET GCELLIDLEBASIC(Mandatory)SET GCELLIDLEFDDBA1(Mandatory)SET GCELLIDLETDDBA1(Mandatory)SET GCELLLCS(Mandatory)SET GCELLOTHBASIC(Mandatory)SET GCELLRACHCCLEV(Mandatory)SET GCELLREV(Mandatory)SET GCELLSBC(Mandatory)SET GCELLSOFT(Mandatory)SET GCELLTMR(Mandatory)SET GCELLADMSTAT(Mandatory)ADD GSMSCB(Optional)SET GCELLCCBASIC(Mandatory)SET GCELLCCAMR(Mandatory)SET GCELLIDLEAD(Mandatory)SET GCELLCCCH(Mandatory)SET GCELLOTHEXT(Mandatory)ADD G3GNCELL(Mandatory)SND GCELLSYSMSG(Mandatory)SET GCELL2GBA1(Mandatory)SET GCELLCHMGBASIC(Mandatory)SET GCELLHO2GBA2(Mandatory)SET GCELLHOAD(Mandatory)SET GCELLHOBASIC(Mandatory)SET GCELLHOCTRL(Mandatory)SET GCELLHOEDBPARA(Mand Type of an index MRFD-210301Configuration Management Enumeration Type BYNAME(By Name), BYID(By Index) BYNAME, BYID None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IDTYPE Index Type BSC6900 ADD G2GNCELL(Mandatory) Index type MRFD-210301Configuration Management Enumeration Type BYNAME(By name), BYID(By index), BYCGI(By CGI) BYNAME, BYID, BYCGI None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IDTYPE Index Type BSC6900 SET GCELLHOINTERRATLDB(Mandatory) Type of an index MRFD-211402MBSC Load Balancing Enumeration Type BYNAME(By Name), BYID(By Index) BYNAME, BYID None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IDTYPE Index Type BSC6900 ADD PTPBVC(Mandatory)SET GCELLEGPRSPARA(Mandatory) SET GCELLGPRS(Mandatory)SET GCELLPRACH(Mandatory)SET GCELLPRIVATEOPTPARA(Mandatory)SET GCELLPSBASE(Mandatory)SET GCELLPSCHM(Mandatory)SET GCELLPSCS(Mandatory)SET GCELLPSI1(Mandatory)SET GCELLPSOTHERPARA(Mandatory)SET GCELLPSPWPARA(Mandatory)SET PSCELLTODSP(Mandatory)SET GCELLNC2PARA(Mandatory)SET GCELLNCRESELECTPARA(Mandatory)SET GCELLNWCTRLMSRPARA(Mandatory)SET GCELLRESELECTPARA(Mandatory)SET GCELLSERVPARA(Mandatory)SET GCELLSTANDARDOPTPARA(Mandatory) Subscribers can specify the cell according to the index or the name. MRFD-210301Configuration Management Enumeration Type BYNAME(By Name), BYID(By Index) BYNAME, BYID None None None Cell None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
IDTYPE Index Type BSC6900 SET BTSFMUABP(Mandatory)SET BTSNFCBBP(Mandatory)SET BTSPMUBP(Mandatory)SET BTSAPMUBP(Mandatory)SET BTSDATUBP(Mandatory)SET BTSDEMUBP(Mandatory)SET BTSDFCUBP(Mandatory)SET BTSDHEUBP(Mandatory)SET BTSDOMUBP(Mandatory)SET BTSDPMUBP(Mandatory)SET BTSDTMUBP(Mandatory)SET BTSDGPSBP(Mandatory)SET BTSPSUFP(Mandatory)SET BTSDDPUBP(Mandatory)SET BTSUSCUBP(Mandatory)ADD BTSRETANT(Mandatory)ADD BTSRXUCHAIN(Mandatory)CBN BTSRXUCHAIN(Mandatory)CHK BTS(Mandatory)SET BTSBREAKPOINT(Mandatory)SET BTSCABPARA(Mandatory)SET BTSJBF(Mandatory)SET BTSLAPDWS(Mandatory)SET BTSPOWERTYPE(Mandatory)SET BTSRXUBP(Mandatory)SPT BTSRXUCHAIN(Mandatory)SET GCELLFREQSCAN(Mandatory)SET BTSAUTODLDACTINFO(Mandatory)SET BTSOTHPARA(Mandatory)SET BTSAUTOPLANCFG(Mandatory)ADD BTSLOCGRP(Mandatory)ADD BTSRXU2LOCGRP(Mandatory)ADD BTSBINDLOCGRP(Mandatory)ADD BTSANTFEEDERBRD(Mandatory)ADD BTSBRD(Mandatory)ADD BTSCABINET(Mandatory)ADD BTSRXUBRD(Mandatory)ADD BTSTRXBRD(Mandatory)SET BTSENVALMPORT(Mandatory)ADD BTSOBJALM Index type of the BTS. BYNAME: query by BTS name; BYID: query by BTS index. GBFD-111202O&M of BTS Enumeration Type BYNAME(By Name), BYID(By Index) HORIZONTAL, VERTICAL None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IDTYPE Index Type BSC6900 SET BTSSHARING(Mandatory)ADD BTSSFPMODE(Mandatory)SET BTSFORBIDTS(Mandatory)SET BTSIDLETS(Mandatory)SET BTSOMLTS(Mandatory)TID BTSABISTS(Mandatory)ADD BTSTOPCONFIG(Mandatory)ADD BTSIPRT(Mandatory)SET BTSETHPORT(Mandatory)SET BTSRINGATTR(Mandatory)SET BTSTRCMPR(Mandatory)SET BTSFLEXABISPARA(Mandatory)SET BTSCTRL(Mandatory)SET BTSIPCLKPARA(Mandatory)ADD BTSPPPLNK(Mandatory)ADD BTSMPGRP(Mandatory)ADD BTSMPLNK(Mandatory)SET BTSIP(Mandatory)SET BTSPINGSW(Mandatory)SET BTSBWPARA(Mandatory)ADD BTSETHMD(Mandatory)ADD BTSETHMA(Mandatory)ADD BTSETHLCMEP(Mandatory)ADD BTSETHRMMEP(Mandatory)LOD BTSSW(Mandatory)LOD RETANTCFG(Mandatory)SAV BTSCLKPARA(Mandatory)SET BTSRACKBC(Mandatory)SET BTSCLKPARA(Mandatory)SET BTSCAVFRQ(Mandatory)SET BTSPMUDEF(Mandatory)SET BTSTMA(Mandatory)SET RETANTENB(Mandatory)STR BTSBATTTST(Mandatory)STR BTSLOG(Mandatory)STR BTSRACKTEMPMON(Mandatory)STR RETANTSCAN(Mandatory)STR TRANSPERFTST(Mandatory)SWP BTSBRD(Mandatory)SWP BTSCLKCLTPT(Mandatory)TST BTSBRD(Ma Index type. BYNAME: query by name; BYID: query by index. GBFD-111202O&M of BTS Enumeration Type BYNAME(By Name), BYID(By Index) BYBTS, BYCELL, BYTRX None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IDX Semilink Index BSC6900 ADD SEMILINK(Mandatory) The index of the Semilink. GBFD-114701Semi-Permanent Connection Interval Type 0~255 0~255, step:1 None None None BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IDXTYPE Index Type BSC6900 SET MSTOCELL(Mandatory)TST SNDRSI(Mandatory)TST UPDMSRAC(Mandatory) Support the index based on the TLLI and IMSI mode. MRFD-210301Configuration Management Enumeration Type BYTLLI(By TLLI), BYIMSI(By IMSI) BYTLLI, BYIMSI None None None Subsystem None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
IDXTYPE Index Type BSC6900 SET PSCELLTODSP(Mandatory) Index type, supporting the index based on the cell and BSC mode. GBFD-111203O&M of BSC Enumeration Type BYCELL(By Cell), BYBSC(By BSC) BYCELL, BYBSC None None None BSC None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
IFCBSHAKEHAND If CB Shake Hand BSC6900 ADD GCBSADDR(Optional) Whether the handshake mechanism is enabled at the Cb interface. Currently, the BSC and the CBC communications through the TCP/IP protocol. Thus, the BSC may not detect communication link disconnection in some cases. The handshake mechanism is used for checking whether a communication link is normal. GBFD-113601Short Message Service Cell Broadcast (TS23) Enumeration Type YES(Yes), NO(No)YES, NO None YES YES Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IFNO Outgoing Interface No. BSC6900 ADD BTSIPRT(Mandatory) Number of the outgoing interface of a link GBFD-111202O&M of BTS Interval Type 0~15 0~3071 None None None IP route None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IFOFFSETHIG Positive or Minus Offset BSC6900 SET BTSRXUBP(Optional) Whether to set the middle frequency offset to positive offset or minus offset GBFD-111202O&M of BTS Enumeration Type Positive(Positive), Minus(Minus) Positive, Minus None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IFOFFSETLOW Indication Offset BSC6900 SET BTSRXUBP(Optional) Indication offset in the middle frequency offset configuration GBFD-111202O&M of BTS Interval Type 0~125 0~125 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IFREPPRO Report Process Flag BSC6900 STR BTSLOG(Optional)ULD BTSLOG(Optional) Whether to report the progress. "NO" indicates that the progress is not reported. "YES" indicates that the progress is reported. GBFD-111202O&M of BTS Enumeration Type NO(Not Report), YES(Need Report) NO, YES None YES None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IGNOREMRNUM Ignore measurement report number BSC6900 SET GCELLHOFAST(Optional) Number of invalid measurement reports allowed when the BSC filters the measurement reports. When the number of received measurement reports is no larger than this parameter, the BSC does not perform filtering or make quick handover judgment. GBFD-510102Fast Move Handover Interval Type 0~32 0~32 None None 1 Cell This parameter is valid only when "QUICKHOEN" in "SET GCELLHOBASIC" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IMEI IMEI BSC6900 CHK INNSPCH(Mandatory)STR CALLRESLOP(Mandatory) Value of an IMEI GBFD-111203O&M of BSC String Type None 1~15 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IMMASSAINTERFTIMER IMM ASS A IF Creation Timer BSC6900 SET GCELLTMR(Optional) Timer for the BSC waiting for a CC message after sending a CR message. If the timer expires, the seized SDCCH is released. GBFD-111804A Interface Protocol Process Interval Type 1000~30000 1000~30000 ms None 5000 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IMMASSCBB Immediate Assignment Optimized BSC6900 SET GCELLBASICPARA(Optional) The channel activation and immediate assignment command are sent at the same time to accelerate the signaling processing rate, thus improving the response speed of the network. None None Enumeration Type NO(NO), YES(YES) NO, YES None None NO Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IMMASSDLSHIFT Move Immediate Assignment Down to BTS BSC6900 SET GCELLPSOTHERPARA(Optional) This parameter specifies whether to support the takeover of the packet immediate assignment by the BTS. It is relative to the uplink immediate assignment. To improve the access rate of the MS, the BSS allocates the uplink TBF resources to the BTS in advance. The BTS sends the immediate assignment message to the MS through the resources allocated by the BSC. When receiving the immediate assignment message, the MS can send the data block. The BTS needs to send the assistant channel request to the BSC. When receiving the request, the BSC sends the immediate assignment request to the BTS to complete the TDF setup flow. GBFD-119202Packet Assignment Taken Over by the BTS Enumeration Type NO(Not Support), YES(Support) NO, YES None None NO Cell None Read & Write Y Cell Not involved None
IMMASSEN TCH Immediate Assignment BSC6900 SET GCELLBASICPARA(Optional) Whether to allow immediate assignment for TCHs. If this parameter is set to YES, when processing a channel request message, the BSC can assign a TCH immediately in the case of no available SDCCH. If this parameter is set to NO, the BSC can assign only an SDCCH when processing a channel access request. GBFD-110502Assignment and Immediate Assignment Enumeration Type NO(No), YES(Yes)NO, YES None None NO Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IMMASSMAXDELAYTIME Max Delay of IMM ASS Retransmit BSC6900 SET GCELLCCTMR(Optional) Maximum time delay in resending an immediate assignment message. Within the period specified by this parameter, an immediate assignment message can be dispatched and retransmitted. Otherwise, the message is not dispatched or retransmitted. GBFD-110502Assignment and Immediate Assignment Interval Type 0~254 0~254 ms None 4 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IMMASSMAXSENDNUM Max Transmit Times of IMM ASS BSC6900 SET GCELLCCTMR(Optional) Maximum number of retransmissions of an immediate assignment message. When the value of this parameter is reached, the immediate assignment message is not retransmitted even if the value of "Max Delay of Imm_Ass Retransmit" is not exceeded. GBFD-110502Assignment and Immediate Assignment Interval Type 1~5 1~5 None None 2 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IMMASSRESENDEN Use IMM ASS Retransmit Parameter BSC6900 SET GCELLCCTMR(Optional) Whether the BSC sends immediate assignment retransmission parameters to the BTS GBFD-110502Assignment and Immediate Assignment Enumeration Type NO(No), YES(Yes)NO, YES None None NO Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IMMASSTAALLOW TA Pref. of Imme-Assign Allowed BSC6900 SET GCELLHOIUO(Optional) Whether to assign channels according to the access_delay value in channel request messages during immediate channel assignment. GBFD-113201Concentric Cell Enumeration Type NO(No), YES(Yes)NO, YES None None NO Cell This parameter is valid only when "IUOTP" in "ADD GCELL" is set to Concentric_cell. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IMMASSTATHRES TA Threshold of Imme-Assign Pref BSC6900 SET GCELLHOIUO(Optional) When the access_delay value in the channel request message is smaller than this parameter, the overlay channels are assigned preferentially; otherwise, the underlay channels are assigned preferentially. GBFD-113201Concentric Cell Interval Type 0~255 0~255 bit None None Cell This parameter is valid only when "IMMASSTAALLOW" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IMMFNAD Immediate Initial Adjust Enable BSC6900 ADD AISSCFG(Optional) Whether to adjust the offset time immediately after the BTS is reset. GBFD-118201Soft-Synchronized Network Enumeration Type NO(NO), YES(YES) NO, YES None NO None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None.
IMMREJWAITINDTIMER T3122 BSC6900 SET GCELLTMR(Optional) Timer carried by the Wait Indication information element when the BSC sends an immediate assignment reject message to an MS.After the MS receives the immediate assignment reject message, the MS reattempts to access the network after the timer expires. GBFD-110502Assignment and Immediate Assignment Interval Type 0~255 0~255 s None 10 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IMSI IMSI BSC6900 CHK INNSPCH(Mandatory)STR CALLRESLOP(Mandatory) Value of an IMSI GBFD-111203O&M of BSC String Type None 1~15 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IMSI IMSI BSC6900 SET MSTOCELL(Mandatory)TST SNDRSI(Mandatory)TST UPDMSRAC(Mandatory) International mobile subscriber identity of the MS. IMSI containing the number 0 to 9. GBFD-111203O&M of BSC String Type None 1~15 characters None None None Subsystem This parameter is valid only when "IDXTYPE" is set to BYIMSI. Read & Write Not involved Not involved Not involved The parameter cannot be modified.
INBSCHOTIMER T3121 BSC6900 SET GCELLTMR(Optional) Timer for the BSC waiting for a handover complete message after sending a handover request acknowledgment message in 2G/3G handover or inter-BSC handover. If the timer expires, a Clear REQ message is reported. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 500~60000 500~60000 ms None 10000 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
INCHLOD Fine Tuning Threshold BSC6900 ADD AISSCFG(Optional) Threshold for fine tuning the BTS clock. If the offset of the BTS clock is smaller than the threshold, no fine tuning is performed. GBFD-118201Soft-Synchronized Network Interval Type 0~8 0~8 bit 4 None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None.
INCHPRD Fine Tuning Period In BSC BSC6900 ADD AISSCFG(Optional) Fine tuning period in the BSC. GBFD-118201Soft-Synchronized Network Interval Type 1~30 1~30 d 3 None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None.
INCLUDEANG Included Angle BSC6900 SET GCELLLCS(Optional) Included angle formed by the major lobe azimuths of the antennas in two cells under one BTS. A major lobe azimuth is measured from the due north to the direction of the cell antenna in a clockwise rotation. GBFD-115402BSS-Based LCS (Cell ID + TA) Interval Type 0~360 0~360 degreeNone None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
INCN In Port Cabinet No. BSC6900 ADD BTSCONNECT(Optional) Number of the in-port cabinet on a BTS GBFD-111202O&M of BTS Interval Type 0~62 0~62 None None None BTS None Read & Write Y BTS Less than 5 minutes This parameter can be modified only when the BTS is deactivated.
INDEN3 Independent E1 Port 3 BSC6900 SET BTSDOMUBP(Optional) Whether to separate E1 from other optical fibers for the use of other devices. If this parameter is set to YES, other BTSs can connect to the BSC through the independent E1 port 3 of the BTS3006C. GBFD-111202O&M of BTS Enumeration Type NO(NO), YES(YES) NO, YES None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
INFHHOLAST Intracell F-H HO Last Time BSC6900 SET GCELLHOBASIC(Optional) The triggering of intra-cell F-H handovers must meet the P/N criteria, that is, when the condition for intra-cell F-H handovers is met for P seconds during N seconds, an intra-cell F-H handover is triggered. This parameter corresponds to the P in the P/N criteria. GBFD-115504AMR FR/HR Dynamic Adjustment Interval Type 1~16 1~16 s None 4 Cell This parameter is valid only when "HOCTRLSWITCH" is set to HOALGORITHM1 and "INTRACELLFHHOEN" is set to YES. The following condition must be met: "INFHHOSTAT" >= "INFHHOLAST". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
INFHHOSTAT Intracell F-H HO Stat Time BSC6900 SET GCELLHOBASIC(Optional) The triggering of intra-cell F-H handovers must meet the P/N criteria, that is, when the condition for intra-cell F-H handovers is met for P seconds during N seconds, an intra-cell F-H handover is triggered. This parameter corresponds to the N in the P/N criteria. GBFD-115504AMR FR/HR Dynamic Adjustment Interval Type 1~16 1~16 s None 5 Cell This parameter is valid only when "HOCTRLSWITCH" is set to HOALGORITHM1 and "INTRACELLFHHOEN" is set to YES. The following condition must be met: "INFHHOSTAT" >= "INFHHOLAST". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
INFOEXCHGLIST Info Exchange Content BSC6900 ADD GNRNC(Mandatory) Information exchange content to be supported MRFD-211402MBSC Load Balancing Bit Field Type CELLCAPCLASS, NACCRELATED CELLCAPCLASS, NACCRELATED None 0 None BSC Set when Allow Info Exchange at Iur-g is set to Yes Read & Write Y Not involved Not involved None
INFRA_RED_MASK Infrared alarm switch BSC6900 ADD EMU(Optional) Infrared alarm switch MRFD-210304Faulty Management Enumeration Type CLOSE(Close), OPEN(Open) CLOSE, OPEN None OPEN None Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
INHOF2HTH F2H HO Threshold BSC6900 SET GCELLHOBASIC(Optional) For an AMR call, if the currently occupied channel is a full rate channel and the Radio Quality Indication (RQI) is always higher than the threshold set by this parameter, an intra-cell F-H handover is triggered. GBFD-115504AMR FR/HR Dynamic Adjustment Interval Type 0~39 0~39 None None 25 Cell This parameter is valid only when "HOCTRLSWITCH" is set to HOALGORITHM1 and "INTRACELLFHHOEN" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
INHOH2FTH H2F HO Threshold BSC6900 SET GCELLHOBASIC(Optional) For an AMR call, if the currently occupied channel is a half rate channel and the Radio Quality Indication (RQI) is always lower than the threshold set by this parameter, an intra-cell H-F handover is triggered. GBFD-115504AMR FR/HR Dynamic Adjustment Interval Type 0~39 0~39 None None 12 Cell This parameter is valid only when "HOCTRLSWITCH" is set to HOALGORITHM1 and "INTRACELLFHHOEN" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
INHOPWROVERLOADTHRESHOLD Power Overload Threshold In Ho. In BSC6900 SET GTRXDEV(Optional) Power overload threshold for allowing incoming handover to the TRX under the prerequisite that the power amplifier of the TRX provides the maximum output power GBFD-111005Enhanced Channel Assignment Algorithm Interval Type 0~50 0~50 W None 8 TRX None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter must be equal to or less than "OUTHOPWROVERLOADTHRESHOLD" to protect the other timeslots/cells from overload and underpower.
INITCDMDF AMR Starting Mode[F] BSC6900 SET GCELLCCAMR(Optional) Initial coding mode used for full rate AMR calls. The four values 0, 1, 2, and 3 of this parameter respectively represent the lowest, low, high, and highest coding rates in the ACS. GBFD-115501AMR FR Interval Type 0~3 0~3 None None 1 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
INITCDMDH AMR Starting Mode[H] BSC6900 SET GCELLCCAMR(Optional) Initial coding mode used for half rate AMR calls. The four values 0, 1, 2, and 3 of this parameter respectively represent the lowest, low, high, and highest coding rates in the ACS. GBFD-115502AMR HR Interval Type 0~3 0~3 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
INITCDMDWB AMR Starting Mode[WB] BSC6900 SET GCELLCCAMR(Optional) Initial coding mode used for broadband AMR calls. The three values 0, 1 and 2 of this parameter respectively represent the lowest, low and highest coding rates in the ACS. GBFD-115507WB AMR Interval Type 0~2 0~2 None None 2 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
INMASK In BSC Mask BSC6900 ADD SEMILINK(Optional) Specify the timeslot mask in BSC. GBFD-114701Semi-Permanent Connection Bit Field Type TS0, TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10, TS11, TS12, TS13, TS14, TS15, TS16, TS17, TS18, TS19, TS20, TS21, TS22, TS23, TS24, TS25, TS26, TS27, TS28, TS29, TS30, TS31 TS0, TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10, TS11, TS12, TS13, TS14, TS15, TS16, TS17, TS18, TS19, TS20, TS21, TS22, TS23, TS24, TS25, TS26, TS27, TS28, TS29, TS30, TS31 None None None BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
INNASSOPTEN OL Subcell Assignment Optimization BSC6900 SET GCELLHOEDBPARA(Optional) Whether to assign channel requests in the overlay subcell to the underlay subcell according to "UL Subcell Lower Load Threshold". If the load of the underlay subcell is lower than "UL Subcell Lower Load Threshold", incoming calls in the overlay subcell will be preferentially assigned to the underlay subcell. GBFD-114402Enhanced Dual-Band Network Enumeration Type NO(No), YES(Yes)NO, YES None None NO Cell This parameter is valid only when "IUOTP" in "ADD GCELL" is set to EDB_cell. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
INNCELLEDGEHOEN Inner Cell EDGE HO Enable BSC6900 SET GCELLHOEDBPARA(Optional) Whether to allow underlay-to-overlay edge handovers GBFD-114402Enhanced Dual-Band Network Enumeration Type NO(No), YES(Yes)NO, YES None None YES Cell This parameter is valid only when "IUOTP" in "ADD GCELL" is set to EDB_cell. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
INNCELLID BSC inner Cell index BSC6900 ADD EXTNCELL(Mandatory) Index of the cell in the BSC. MRFD-210301Configuration Management Interval Type 0~2047 0~2047 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None.
INNCELLNAME BSC Inner Cell Name BSC6900 ADD EXTNCELL(Mandatory) Name of the cell in the BSC. MRFD-210301Configuration Management String Type None 1~64 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None.
INNLOADHOEN Load HO of OL Subcell to UL Subcell BSC6900 SET GCELLHOEDBPARA(Optional) Whether to allow underlay-to-overlay load handovers GBFD-114402Enhanced Dual-Band Network Enumeration Type NO(No), YES(Yes)NO, YES None None NO Cell This parameter is valid only when "IUOTP" in "ADD GCELL" is set to EDB_cell. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
INNLOADHOPERI OL Subcell Load Diversity HO Period BSC6900 SET GCELLHOEDBPARA(Optional) Overlay-to-underlay load handovers are performed by levels. This parameter indicates the duration of each level. GBFD-114402Enhanced Dual-Band Network Interval Type 1~255 1~255 s None 10 Cell This parameter is valid only when "INNLOADHOEN" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
INNLOADHOSTEP Step Length of OL Subcell Load HO BSC6900 SET GCELLHOEDBPARA(Optional) Level step during overlay-to-underlay hierarchical load handovers GBFD-114402Enhanced Dual-Band Network Interval Type 0~63 0~63 dB None 5 Cell This parameter is valid only when "INNLOADHOEN" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
INNSERIOVERLDTHRED Inner Cell Serious OverLoad Thred BSC6900 SET GCELLHOEDBPARA(Optional) In an enhanced dual-band network, if the load of the overlay subcell is higher than this parameter, the system cannot initiate an underlay-to-overlay handover. GBFD-114402Enhanced Dual-Band Network Interval Type 0~100 0~100 per cent None 90 Cell This parameter is valid only when "OUTLOADHOENABLE" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
INPN In BSC Port No. BSC6900 ADD SEMILINK(Mandatory) In BSC Port No.. GBFD-114701Semi-Permanent Connection Interval Type 0~335 0~335 None None None BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
INPN BTS In Port No. BSC6900 ADD BTSCONNECT(Mandatory) Number of a BTS port GBFD-111202O&M of BTS Interval Type 0~23 0~23 None None None BTS None Read & Write Y BTS Less than 5 minutes This parameter can be modified only when the BTS is deactivated.
INPORTNO DXX In Port No. BSC6900 ADD DXXTSEXGRELATION(Mandatory) In-port number of a DXX GBFD-111203O&M of BSC Interval Type 0~15 0~15 None None None BTS None Read & Write Y BTS Less than 5 minutes None
INPUTMD Latitude and Longitude Input Mode BSC6900 SET GCELLLCS(Optional) Mode of inputting the latitude and longitude of a cell location GBFD-115402BSS-Based LCS (Cell ID + TA) Enumeration Type Degree(Degree), D_min_sec(Degree Minute Second) Degree, D_min_sec None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
INRBSCSDHOEN Inter-BSC SDCCH HO ALLowed BSC6900 SET GCELLHOCTRL(Optional) Whether to allow inter-BSC SDCCH handovers GBFD-110608SDCCH Handover Enumeration Type NO(No), YES(Yes)NO, YES None None NO Cell This parameter is valid only when "SIGCHANHOEN" in "SET GCELLHOBASIC" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
INSN In BSC Slot No. BSC6900 ADD SEMILINK(Mandatory) In BSC Slot No.. GBFD-114701Semi-Permanent Connection Interval Type 0~27 0~27 None None None BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
INSN In Port Slot No. BSC6900 ADD BTSCONNECT(Optional) Number of the in-port slot on a BTS GBFD-111202O&M of BTS Interval Type 0~23 0~23 None None None BTS None Read & Write Y BTS Less than 5 minutes This parameter can be modified only when the BTS is deactivated.
INSRN In BSC Subrack No. BSC6900 ADD SEMILINK(Mandatory) In BSC Subrack No.. GBFD-114701Semi-Permanent Connection Interval Type 0~11 0~11 None None None BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
INSRN In Port Subrack No. BSC6900 ADD BTSCONNECT(Optional) Number of the in-port subrack on a BTS GBFD-111202O&M of BTS Interval Type 0~254 0~254 None None None BTS None Read & Write Y BTS Less than 5 minutes This parameter can be modified only when the BTS is deactivated.
INT Broadcast Interval BSC6900 ADD GSMSCB(Mandatory) Time interval for sending a simple cell broadcast message GBFD-113602Simplified Cell Broadcast Interval Type 2~3600 2~3600 s None 60 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
INTELEVHOHYST Adjacent Cell Inter-layer HO Hysteresis BSC6900 ADD G2GNCELL(Optional) Hysteresis value during the handovers between cells on different layers or of different priorities. This value is used to suppress inter-layer ping-pong handovers. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 0~127 0~127 dB None 67 Cell Inter-layer HO threshold of the serving cell = "Inter-layer HO threshold" - "Inter-layer HO Hysteresis".Inter-layer HO threshold of the neighboring cell = "Inter-layer HO threshold" + "Adjacent Cell Inter-layer HO Hysteresis" - 64.The value of "Inter-layer HO threshold" can be set through "SET GCELLHOBASIC". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
INTERBANDSTATALGO Interfere Band Stat Algorithm Type BSC6900 SET GCELLSOFT(Optional) Type of an interference band statistics algorithm used when the frequency scanning function is enabled GBFD-112401Cell Frequency Scan Enumeration Type INTBANI(INTBANI), INTBANII(INTBANII) INTBANI, INTBANII None None INTBANII Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
INTERCELLHYST Inter-cell HO Hysteresis BSC6900 ADD G2GNCELL(Optional) Reduces ping-pong handovers between cells on a same layer. This parameter is invalid when cells are on different layers. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 0~63 0~63 dB None In densely populated urban areas, the recommended value is 4; in the suburbs, the recommended value is 8. Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
INTERFEREHOPENTIME Penalty time on interfere HO BSC6900 SET GCELLHOFITPEN(Optional) Specifies an interval between two consecutive interference handovers GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 0~255 0~255 s None 15 Cell This parameter is valid only when "HOCTRLSWITCH" in "SET GCELLHOBASIC" is set to HOALGORITHM2. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
INTERFERELASTTIME Interfere HO valid time BSC6900 SET GCELLHOBASIC(Optional) The triggering of interference handovers must meet the P/N criteria, that is, when P out of N measurement reports meet the condition for interference handovers, a concentric circle handover is triggered. This parameter corresponds to the P in the P/N criteria. GBFD-510501HUAWEI II Handover Interval Type 1~16 1~16, step:0.5 s None 2 Cell This parameter is valid only when "INTERFHOEN" is set to YES and "HOCTRLSWITCH" is set to HOALGORITHM2. The following condition must be met: "INTERFERESTATTIME" >= "INTERFERELASTTIME". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
INTERFERESTATTIME Interfere HO static time BSC6900 SET GCELLHOBASIC(Optional) The triggering of interference handovers must meet the P/N criteria, that is, when P out of N measurement reports meet the condition for interference handovers, a concentric circle handover is triggered. This parameter corresponds to the N in the P/N criteria. GBFD-510501HUAWEI II Handover Interval Type 0~16 1~16, step:0.5 s None 3 Cell This parameter is valid only when "INTERFHOEN" is set to YES and "HOCTRLSWITCH" is set to HOALGORITHM2. The following condition must be met: "INTERFERESTATTIME" >= "INTERFERELASTTIME". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
INTERFHOEN Interference HO Allowed BSC6900 SET GCELLHOBASIC(Optional) Whether to allow the interference handover algorithm. Interference handovers are triggered when the receive level is higher than the receive threshold while the transmit quality is lower than the interference handover quality threshold, that is, when the MSs are subject to all kinds of radio interferences. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Enumeration Type NO(No), YES(Yes)NO, YES None None YES Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
INTERFPRIALLOW Interf. Priority Allowed BSC6900 SET GCELLCHMGAD(Optional) Whether to consider interference priorities during channel assignment GBFD-111005Enhanced Channel Assignment Algorithm Enumeration Type NO(No), YES(Yes)NO, YES None None YES Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
INTERFTHRES0 Interference Band Threshold 0 BSC6900 SET GCELLOTHEXT(Optional) Threshold used for interference measurement.The BSS measures the uplink quality of the radio channels occupied by MSs, and calculates and reports the interference on each of the idle channels. This helps the BSC to assign channels. According to the strength of interference signals, the interference signals are classified into five interference levels. The values of these levels are called interference band thresholds. The BTS determines the current interference level based on these thresholds, and then reports a radio resource indication message to the BSC. The BSC compares the busy and idle channels reported in the measurement report and in the radio resource indication message to determine whether to perform a handover. The interference band statistics result provides reference for threshold setting and interference analysis. For details, see GSM Rec. 08.08 and GSM Rec. 08.58. GBFD-111005Enhanced Channel Assignment Algorithm Interval Type 48~115 48~115 None None None Cell The setting of this parameter must meet the following condition: "INTERFTHRES0" > "INTERFTHRES1". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
INTERFTHRES1 Interference Band Threshold 1 BSC6900 SET GCELLOTHEXT(Optional) Threshold used for interference measurement.The BSS measures the uplink quality of the radio channels occupied by MSs, and calculates and reports the interference on each of the idle channels. This helps the BSC to assign channels. According to the strength of interference signals, the interference signals are classified into five interference levels. The values of these levels are called interference band thresholds. The BTS determines the current interference level based on these thresholds, and then reports a radio resource indication message to the BSC. The BSC compares the busy and idle channels reported in the measurement report and in the radio resource indication message to determine whether to perform a handover. The interference band statistics result provides reference for threshold setting and interference analysis. For details, see GSM Rec. 08.08 and GSM Rec. 08.58. GBFD-111005Enhanced Channel Assignment Algorithm Interval Type 48~115 48~115 None None None Cell The setting of this parameter must meet the following condition: "INTERFTHRES1" > "INTERFTHRES2". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
INTERFTHRES2 Interference Band Threshold 2 BSC6900 SET GCELLOTHEXT(Optional) Threshold used for interference measurement.The BSS measures the uplink quality of the radio channels occupied by MSs, and calculates and reports the interference on each of the idle channels. This helps the BSC to assign channels. According to the strength of interference signals, the interference signals are classified into five interference levels. The values of these levels are called interference band thresholds. The BTS determines the current interference level based on these thresholds, and then reports a radio resource indication message to the BSC. The BSC compares the busy and idle channels reported in the measurement report and in the radio resource indication message to determine whether to perform a handover. The interference band statistics result provides reference for threshold setting and interference analysis. For details, see GSM Rec. 08.08 and GSM Rec. 08.58. GBFD-111005Enhanced Channel Assignment Algorithm Interval Type 48~115 48~115 None None None Cell The setting of this parameter must meet the following condition: "INTERFTHRES2" > "INTERFTHRES3". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
INTERFTHRES3 Interference Band Threshold 3 BSC6900 SET GCELLOTHEXT(Optional) Threshold used for interference measurement.The BSS measures the uplink quality of the radio channels occupied by MSs, and calculates and reports the interference on each of the idle channels. This helps the BSC to assign channels. According to the strength of interference signals, the interference signals are classified into five interference levels. The values of these levels are called interference band thresholds. The BTS determines the current interference level based on these thresholds, and then reports a radio resource indication message to the BSC. The BSC compares the busy and idle channels reported in the measurement report and in the radio resource indication message to determine whether to perform a handover. The interference band statistics result provides reference for threshold setting and interference analysis. For details, see GSM Rec. 08.08 and GSM Rec. 08.58. GBFD-111005Enhanced Channel Assignment Algorithm Interval Type 48~115 48~115 None None None Cell The setting of this parameter must meet the following condition: "INTERFTHRES3" > "INTERFTHRES4". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
INTERFTHRES4 Interference Band Threshold 4 BSC6900 SET GCELLOTHEXT(Optional) Threshold used for interference measurement.The BSS measures the uplink quality of the radio channels occupied by MSs, and calculates and reports the interference on each of the idle channels. This helps the BSC to assign channels. According to the strength of interference signals, the interference signals are classified into five interference levels. The values of these levels are called interference band thresholds. The BTS determines the current interference level based on these thresholds, and then reports a radio resource indication message to the BSC. The BSC compares the busy and idle channels reported in the measurement report and in the radio resource indication message to determine whether to perform a handover. The interference band statistics result provides reference for threshold setting and interference analysis. For details, see GSM Rec. 08.08 and GSM Rec. 08.58. GBFD-111005Enhanced Channel Assignment Algorithm Interval Type 48~115 48~115 None None None Cell The setting of this parameter must meet the following condition: "INTERFTHRES4" > "INTERFTHRES5". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
INTERFTHRES5 Interference Band Threshold 5 BSC6900 SET GCELLOTHEXT(Optional) Threshold used for interference measurement.The BSS measures the uplink quality of the radio channels occupied by MSs, and calculates and reports the interference on each of the idle channels. This helps the BSC to assign channels. According to the strength of interference signals, the interference signals are classified into five interference levels. The values of these levels are called interference band thresholds. The BTS determines the current interference level based on these thresholds, and then reports a radio resource indication message to the BSC. The BSC compares the busy and idle channels reported in the measurement report and in the radio resource indication message to determine whether to perform a handover. The interference band statistics result provides reference for threshold setting and interference analysis. For details, see GSM Rec. 08.08 and GSM Rec. 08.58. GBFD-111005Enhanced Channel Assignment Algorithm Interval Type 48~115 48~115 None None None Cell The setting of this parameter must meet the following condition: "INTERFTHRES4" > "INTERFTHRES5". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
INTERIORSYNCTMR BSC Inter Synchronize Protect Time BSC6900 ADD AISSCFG(Optional) Value of the timer for synchronization between BSCs. If a BSC fails to synchronize with the control BSC before the timer expires, the BSC starts to synchronize the BTSs under its control. GBFD-118201Soft-Synchronized Network Interval Type 0~60 0~60 d 3 None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None.
INTERPERIOD Interference Calculation Period BSC6900 SET GCELLOTHEXT(Optional) Period during which interference levels are averaged. The interference levels on idle channels are averaged before the BTS sends a radio resource indication message to the BSC. The averaging result is used for classifying the interference levels on idle channels into five interference bands. For details, see GSM Rec. 08.08, 08.58, and 12.21. GBFD-111005Enhanced Channel Assignment Algorithm Interval Type 1~31 1~31, step: 480 ms None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved 1. Interference band 0 is not counted in the traffic statistics.2. In the following BTSs, the value range of this parameter is 115 to 85: BTS2X of all the versions, BTS3X 03.1130 of the earlier versions, 3001C07.0301 of the earlier versions, and 3002C02.0820 of the earlier versions. If this parameter is set to a value beyond the range, the concerned cells cannot work.3. In the following BTSs, the value range is 115 to 48: BTS3X 03.1130 and its later versions, 3001c 07.0301 and its later versions, 3002c 02.0820 and its later versions, and double-transceiver BTSs.4. If the value of this parameter is too great, the averaging result cannot accurately reflect changes. If the value is too small, frequent averaging of interference levels causes a waste of resources.
INTERRATCELLRESELEN Inter-RAT Cell Reselection Enable BSC6900 SET GCELLHOBASIC(Optional) Whether to allow cell reselection from 2G cells to 3G cells GBFD-114301GBFD-114302 GSM/WCDMA InteroperabilityGSM/TD-SCDMA Interoperability Enumeration Type NO(No), YES(Yes)NO, YES None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
InterRatCsServiceLoadHoThrd Inter-RAT CS Service HO Load Threshold BSC6900 SET GCELLHOINTERRATLDB(Optional) Threshold for setting the flag of accepting inter-RAT CS service handover of a 2G cell MRFD-211402MBSC Load Balancing Interval Type 1~100 {1~100} None None None BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
INTERRATINBSCHOEN Inter-RAT In BSC Handover Enable BSC6900 SET GCELLHOBASIC(Optional) Whether to allow handovers from 3G cells to 2G cells GBFD-114301GBFD-114302 GSM/WCDMA InteroperabilityGSM/TD-SCDMA Interoperability Enumeration Type NO(No), YES(Yes)NO, YES None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
InterRATLoadHoEcNoBandWidth Inter-RAT Load HO Bandwidth [EcNo] BSC6900 SET GCELLHOINTERRATLDB(Optional) Width of load band [EcNo] during the inter-RAT hierarchical load-based handover MRFD-211402MBSC Load Balancing Interval Type 1~49 {1~49} dB None None BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
InterRATLoadHoEcNoStart Inter-RAT Load HO EcNo at Start Point BSC6900 SET GCELLHOINTERRATLDB(Optional) Initial EcNo value of the inter-RAT load-based handover band MRFD-211402MBSC Load Balancing Interval Type 0~49 {0~49} dB None None BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
InterRATLoadHoEcNoStep Inter-RAT Hierarchy Load HO Step [EcNo] BSC6900 SET GCELLHOINTERRATLDB(Optional) Step of changing the EcNo value during the inter-RAT hierarchical load-based handover MRFD-211402MBSC Load Balancing Interval Type 1~49 {1~49} dB None None BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
InterRATLoadHoRSCPBandWidth Inter-RAT Load HO Bandwidth [RSCP] BSC6900 SET GCELLHOINTERRATLDB(Optional) Width of load band [RSCP] during the inter-RAT hierarchical load-based handover MRFD-211402MBSC Load Balancing Interval Type 1~91 {1~91} dB None None BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
InterRATLoadHoRSCPStart Inter-RAT Load HO RSCP at Start Point BSC6900 SET GCELLHOINTERRATLDB(Optional) Initial RSCP value of the inter-RAT load-based handover band MRFD-211402MBSC Load Balancing Interval Type 0~91 {0~91} dB None None BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
InterRATLoadHoRSCPStep Inter-RAT Hierarchy Load HO Step [RSCP] BSC6900 SET GCELLHOINTERRATLDB(Optional) Step of changing the RSCP value during the inter-RAT hierarchical load-based handover MRFD-211402MBSC Load Balancing Interval Type 1~91 {1~91} dB None None BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
INTERRATOUTBSCHOEN Inter-RAT Out BSC Handover Enable BSC6900 SET GCELLHOBASIC(Optional) Whether to allow handovers from 2G cells to 3G cells GBFD-114301GBFD-114302 GSM/WCDMA InteroperabilityGSM/TD-SCDMA Interoperability Enumeration Type NO(No), YES(Yes)NO, YES None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
InterRatServiceLoadHoSwitch Allow Inter-RAT Load HO in Access State BSC6900 SET GCELLHOINTERRATLDB(Optional) When Service-based is selected, the destination cell is filtered according to the destination cell load.When Load-based is selected, the destination cell is filtered according to the destination cell load and the load balance between a 2G cell and a 3G cell.When Dynamic Service/Load-based is selected, the access cell is selected through the Service-based or Load-based algorithm which is selected dynamically on the basis of cell load.When CN Service-based is selected, determine whether the inter-RAT handover is performed on the basis of the core network service attribute.When OFF is selected, the inter-RAT service handover and load handover in the access state are not performed. MRFD-211402MBSC Load Balancing Enumeration Type Service-based(Service-based), Load-based(Load-based), Dynamic-based(Dynamic Service/Load-based), CnService-based(CN Service-based), OFF(OFF) {0~4} None None None BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
INTERVAL Relative Time BSC6900 EXP LOG(Optional) Time span before the command is executed. The logs generated within the time span are to be exported. GBFD-111203MRFD-210305 O&M of BSCSecurity Management Interval Type 1~240 1~240 h 72 72 RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
INTERVAL Send PKT Interval[s] BSC6900 STR ETHOAMLOOPTST(Optional) Interval for sending packets to test Ethernet OAM loop GBFD-118630Ethernet OAM Interval Type 1~10 1~10 s 1 1 BSC6900None Read & Write Y Ethernet port The loopback keeps interrupting the services until the loopback is cancelled. None
INTFREQUENCY Interference Frequency BSC6900 SET GCELLEXTMSRPARA(Optional) Frequency index of the interference measurement in type 3 of an extension measurement report GBFD-110801GBFD-110802 Processing of Measurement ReportPre-processing of Measurement Report Interval Type 0~31 0~31 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
INTOINNREXLEVTHRED Incoming OL Subcell HO Level TH BSC6900 SET GCELLHOEDBPARA(Optional) Lower threshold of the overlay level during underlay-to-overlay handovers. When the receive level of an MS is higher than this threshold, the MS can be switched to the overlay subcell. GBFD-114402Enhanced Dual-Band Network Interval Type 0~63 0~63 dB None 30 Cell This parameter is valid only when "IUOTP" in "ADD GCELL" is set to EDB_cell. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
INTRABSCHOTIMER T3103A BSC6900 SET GCELLTMR(Optional) Timer started after the BSC delivers a handover command in an intra-BSC inter-cell handover. If the BSC receives a handover complete message before this timer expires, the timer stops. If this timer expires, the BSC considers the handover as failed. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 500~60000 500~60000 ms None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
INTRACELLFHHOEN Intracell F-H HO Allowed BSC6900 SET GCELLHOBASIC(Optional) Whether to allow AMR handovers. This parameter has no impact on dynamic non-AMR F-H handovers. GBFD-115504AMR FR/HR Dynamic Adjustment Enumeration Type NO(No), YES(Yes)NO, YES None None YES Cell This parameter is valid only when "HOCTRLSWITCH" is set to HOALGORITHM1 and "INTRACELLHOEN" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
INTRACELLHOEN Intracell HO Allowed BSC6900 SET GCELLHOBASIC(Optional) Whether to allow intra-cell handovers GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Enumeration Type NO(No), YES(Yes)NO, YES None None In the hot-spot areas, densely populated urban areas, urban areas, suburbs, and rural areas, the recommended value is YES; in the high-speed circumstances, the recommended value is NO. Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
INTRACELLHOTIMER T3103C BSC6900 SET GCELLTMR(Optional) Timer started after the BSC delivers a handover command in an intra-BSC intra-cell handover. If the BSC receives a handover complete message before this timer expires, the timer stops. If this timer expires, the BSC considers the handover as failed. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 500~60000 500~60000 ms None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
INTRAMBSC Co-MBSC BSC6900 ADD GNRNC(Mandatory) Whether it is an RNC under the same MBIC in GU mode MRFD-211402MBSC Load Balancing Enumeration Type NO(No), YES(Yes)NO, YES None None None BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IntRATLoadHOEcNoThr Inter-RAT Load HO EcNo Threshold BSC6900 SET GCELLHOINTERRATLDB(Optional) Minimum Ec/No value of a 3G cell during the load-based GSM-to-UMTS handover MRFD-211402MBSC Load Balancing Interval Type 0~49 {0~49} dB None None BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IntRATLoadHoPeriod Inter-RAT Hierarchical Load HO Period BSC6900 SET GCELLHOINTERRATLDB(Optional) When the load of a cell is greater than or equal to Load HO Threshold, all the calls in the serving cell send handover requests simultaneously. Thus, the load on the CPU increases rapidly. In some cases, the cell is congested and call drops might occur. Therefore, the BSC adopts the hierarchical load handover algorithm to control the number of calls to be handed over at each level. This parameter specifies the duration for performing the load-based handover at each level. MRFD-211402MBSC Load Balancing Interval Type 1~255 {1~255} s None None BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IntRATLoadHORSCPThr Inter-RAT Load HO RSCP Threshold BSC6900 SET GCELLHOINTERRATLDB(Optional) Minimum RSCP value of a 3G cell during the load-based GSM-to-UMTS handover MRFD-211402MBSC Load Balancing Interval Type 0~91 {0~91} dB None None BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
INTSN In BSC Start Timeslot No. BSC6900 ADD SEMILINK(Mandatory) In BSC Start Timeslot No.. GBFD-114701Semi-Permanent Connection Interval Type 0~255 0~255 None None None BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
INTSNO DXX In Time Slot No. BSC6900 ADD DXXTSEXGRELATION(Mandatory) Number of a DXX In-timeslot GBFD-111203O&M of BSC Interval Type 0~31 0~31 None None None BTS None Read & Write Y BTS Less than 5 minutes None
INTV Time Interval[min] BSC6900 ADD SUBTSK(Optional) Interval for executing the scheduled subtask. If the time mode is set to "DAILY_C", "WEEKLY_C", or "MONTHLY_C", you should set this parameter. GBFD-111203O&M of BSC Interval Type 1~1440 1~1440 minute 30 None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
INTV OMU Automatic Switchover Interval[Days] BSC6900 SET ASWPARA(Mandatory) Automatic switchover interval. This parameter needs to be set only when "OMU automatic switchover switch" is set to "ON". The minimum automatic switchover interval is 30 days and the maximum automatic switchover interval is 1024 days. GBFD-111203O&M of BSC Interval Type 30~1024 30~1024 None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
INVALBSICEN Invalid BSIC Reporting BSC6900 SET GCELLCCUTRANSYS(Optional) Whether a measurement report can contain the information about a cell with an invalid BSIC GBFD-117501Enhanced Measurement Report(EMR) Enumeration Type NO(No), YES(Yes)NO, YES None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IP IP Address BSC6900 ADD XPUVLAN(Mandatory) IP address MRFD-210301Configuration Management IP Address Type None 0.0.0.0~255.255.255.255 None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IP IP Address BSC6900 EXP LOG(Optional)ADD SNTPSRVINFO(Mandatory)DLD LICENSE(Mandatory)ULD LICENSE(Mandatory) IP address of the server GBFD-111203O&M of BSC IP Address Type None 0.0.0.0~255.255.255.255 None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IP Local IP Address BSC6900 ADD NSVLLOCAL(Mandatory) IP address of the local NSVL. GBFD-118603Gb over IP IP Address Type None 0.0.0.0~255.255.255.255 None None None NSE None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
IP Remote IP Address BSC6900 ADD NSVLREMOTE(Mandatory) IP address of the remote NSVL. GBFD-118603Gb over IP IP Address Type None 0.0.0.0~255.255.255.255 None None None NSE None Read & Write Y NSE Services are interrupted unless the NSVL configuration is the same as the SGSN configuration at the BSC. None
IP Physical IP BSC6900 SET BTSETHPORT(Optional) IP address of a BTS port. It cannot be the same as any IP address in the BSC. GBFD-118601Abis over IP IP Address Type None 0.0.0.0~255.255.255.255 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IP FTPServer IP BSC6900 DLD BTSSW(Mandatory)DLD RETANTCFG(Mandatory)ULD BTSDEVFILE(Mandatory)DLD BTSPATCH(Mandatory)ULD BTSLOG(Mandatory) IP address of the FTP server GBFD-111202O&M of BTS IP Address Type None 0.0.0.0~255.255.255.255 None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IPADDR Local IP address BSC6900 ADD IPPATH(Mandatory) The local IP address must be the configured IP address (including the IP address and port address of the interface board). None None IP Address Type None 0.0.0.0~255.255.255.255 None None None IP path The "IPADDR" in "ADD IPPATH" can not be at one network segment with the peer IP address of SCTPLNK or IPPATH whose local IP address is device IP address of FG2/GOU in this subrack;"IPADDR" and "PEERIPADDR" in "ADD IPPATH" must be at one network segment;("IPADDR","PEERIPADDR","PEERMASK" in "ADD IPPATH") conflicts with other IPPATH whose type is IUPS. Read & Write Not involved Not involved Not involved The parameter cannot be modified.
IPADDR IP address BSC6900 ADD DEVIP(Mandatory) IP address of the board None None IP Address Type None 0.0.0.0~255.255.255.255 None None None BSC6900None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
IPADDR Local IP address BSC6900 ADD ETHIP(Mandatory) Local IP address of the Ethernet port. None None IP Address Type None 0.0.0.0~255.255.255.255 None None None Ethernet port None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
IPADDR Packet source IP address BSC6900 ADD ICMPGUARD(Mandatory) Source IP address of the packet for preventing the ICMP attack None None IP Address Type None 0.0.0.0~255.255.255.255 None None None Ethernet port None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
IPADDR Next Hop IP address. BSC6900 ADD VLANID(Mandatory) IP address of the next hop None None IP Address Type None 0.0.0.0~255.255.255.255 None None None BSC6900None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
IPADDR Local IP address BSC6900 ADD ETHTRKIP(Mandatory) Local IP address of the aggregation group. MRFD-210103Link aggregation IP Address Type None 0.0.0.0~255.255.255.255 None None None Ethernet port None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
IPADDR IP Address BSC6900 ADD SGSNROUTEINFO(Mandatory) IP address of the router. GBFD-118603Gb over IP IP Address Type None 0.0.0.0~255.255.255.255 None None None BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IPADDR1 IP Address1 BSC6900 ADD SGSN(Mandatory) The first IP address of the SGSN. GBFD-118603Gb over IP IP Address Type None 0.0.0.0~255.255.255.255 None None None BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IPADDR1 Clock Server IP Address 1 BSC6900 SET BTSIPCLKPARA(Mandatory) It must be the valid address of the A, B, or C type and cannot be the broadcast address or network address. GBFD-118606Clock over IP IP Address Type None 0.0.0.0~255.255.255.255 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IPADDR2 IP Address2 BSC6900 ADD SGSN(Optional) The second IP address of the SGSN. GBFD-118603Gb over IP IP Address Type None 0.0.0.0~255.255.255.255 None None None BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IPADDR2 Clock Server IP Address 2 BSC6900 SET BTSIPCLKPARA(Mandatory) It must be the valid address of the A, B, or C type and cannot be the broadcast address or network address. GBFD-118606Clock over IP IP Address Type None 0.0.0.0~255.255.255.255 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IPADDR3 IP Address3 BSC6900 ADD SGSN(Optional) The third IP address of the SGSN. GBFD-118603Gb over IP IP Address Type None 0.0.0.0~255.255.255.255 None None None BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IPADDR4 IP Address4 BSC6900 ADD SGSN(Optional) The fourth IP address of the SGSN. GBFD-118603Gb over IP IP Address Type None 0.0.0.0~255.255.255.255 None None None BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IPHC Head compress BSC6900 ADD PPPLNK(Optional) Compression function of the IP header of the PPP link GBFD-118611GBFD-118622 Abis IP over E1/T1A IP over E1/T1 Enumeration Type No_HC(No_HC), UDP/IP_HC(UDP/IP_HC), RTP/UDP/IP_HC(RTP/UDP/IP_HC) No_HC, UDP/IP_HC, RTP/UDP/IP_HC None UDP/IP_HC UDP/IP_HC PPP link None Read & Write Y BSC6900 Interrupt the service until negotiate successfully again. Negotiation can succeed only when the configuration is consistent on the local and peer ends.
IPHC Head compress BSC6900 ADD MPGRP(Optional) Compression function of the IP header of the PPP link GBFD-118611GBFD-118622 Abis IP over E1/T1A IP over E1/T1 Enumeration Type No_HC(No_HC), UDP/IP_HC(UDP/IP_HC), RTP/UDP/IP_HC(RTP/UDP/IP_HC) No_HC, UDP/IP_HC, RTP/UDP/IP_HC None UDP/IP_HC UDP/IP_HC MP groupNone Read & Write N (No impact on the UE in idle mode) Not involved Not involved No_HC: disable the header compression function; RTP/UDP/IP_HC: enable the RTP/UDP/IP/PPP function
IPINDEX IP address index BSC6900 ADD ETHIP(Mandatory) IP address index of the Ethernet port None None Interval Type 0~5 0~5 None None None Ethernet port None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
IPINDEX IP address index BSC6900 ADD ETHTRKIP(Mandatory) IP address index of the aggregation group MRFD-210103Link aggregation Interval Type 0~5 0~5 None None None Ethernet port None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
IPMUXINDEX IP MUX Index BSC6900 ADD IPMUX(Optional) IP packet multiplex index GBFD-118604GBFD-118610 Abis MUXUDP MUX for A Transmission Interval Type 0~12999 0~12999 None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IPPHYTRANSTYPE IP Phy Trans Type BSC6900 ADD BTS(Optional) Type of the physical IP transmission medium GBFD-118601Abis over IP Enumeration Type IP_OVER_FE/GE, IP_OVER_E1 IP_OVER_FE/GE, IP_OVER_E1 None IP_OVER_FE/GE IP_OVER_FE/GE BTS This parameter is valid only when "SERVICEMODE" in "MOD BTS" is set to IP. Read & Write Y BTS Less than 5 minutes This parameter depends on the type of the actual physical IP transport cable of the BTS.
IPPHYTRANSTYPE IP Phy Trans Type BSC6900 ADD BTSAUTOPLAN(Optional) Type of IP physical transmission cable medium, E1 or FE/GE. GBFD-118601Abis over IP Enumeration Type IP_OVER_FE/GE(IP_OVER_FE/GE), IP_OVER_E1(IP_OVER_E1) IP_OVER_FE/GE, IP_OVER_E1 None None None BTS None Read & Write Y BTS Less than 5 minutes This parameter must be set according to the medium type of the actual IP transmission cable used by the BTS.
ISADDEDTMPCONTROL DHEU heater Control Allowed BSC6900 SET BTSDHEUBP(Optional) Whether to enable the heater.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. GBFD-111202O&M of BTS Enumeration Type NO(NO), YES(YES) NO, YES None None NO BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ISBASICBSC Base BSC BSC6900 ADD AISSCFG(Mandatory) Whether the BSC is a reference BSC. GBFD-118201Soft-Synchronized Network Enumeration Type NO(NO), YES(YES) NO, YES None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None.
ISCHAINNCELL Chain neighbor cell BSC6900 ADD G2GNCELL(Optional) Whether the cell is a chain neighboring cell GBFD-510103Chain Cell Handover Enumeration Type NO(No), YES(Yes)NO, YES None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ISCLKREDUCY Clock Server Redundancy BSC6900 SET BTSIPCLKPARA(Mandatory) Whether to support clock server redundancy configuration. GBFD-118606Clock over IP Enumeration Type UNSUPPORT(Not Support Reducy), SUPPORT(Support Reducy) UNSUPPORT, SUPPORT None None None BTS If the redundancy configuration mode is not supported, only one clock server can be configured. Otherwise, two clock servers can be configured. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ISCLKREDUCYBAK Clock Server Redundancy BSC6900 SET BTSIPCLKPARA(Mandatory) Whether to support clock server redundancy configuration. GBFD-118606Clock over IP Enumeration Type UNSUPPORT(Not Support Reducy), SUPPORT(Support Reducy) UNSUPPORT, SUPPORT None None None BTS If the redundancy configuration mode is not supported, only one clock server can be configured. Otherwise, two clock servers can be configured. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ISCONFIGEDRING Config Ring BSC6900 ADD BTS(Optional) Whether to enable the BTS to support ring networking. IP BTS is not support this parameter. GBFD-117801Ring Topology Enumeration Type NO(No), YES(Yes)NO, YES None NO NO BTS None Read & Write Y BTS Less than 5 minutes None
ISCONFIGTHD Is Configure Check Threadhold BSC6900 ADD BTSRXUBRD(Optional) Is Configure Check Threadhold. GBFD-111202O&M of BTS Enumeration Type NO(NO), YES(YES) YES, NO None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ISEDGESUPPORT EDGE support in external neighbour cell BSC6900 ADD GEXT2GCELL(Optional) A service support attribute of a cell, that is, whether an external GSM cell supports EDGE GBFD-114201EGPRS Enumeration Type NO(Not support), YES(Support) NO, YES None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ISFIRSTCLASS Is First Class Transport Resource Group BSC6900 ADD RSCGRP(Mandatory) Whether to indicate the first class transport resource group None None Enumeration Type NO(NO), YES(YES) NO, YES None None None Transmission resource group None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
ISGPRSSUPPORT GPRS support in external neighbour cell BSC6900 ADD GEXT2GCELL(Optional) A service support attribute of a cell, that is, whether an external GSM cell supports GPRS GBFD-114101GPRS Enumeration Type NO(Not support), YES(Support) NO, YES None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ISMAINBCCH Is Main BCCH TRX BSC6900 ADD GTRX(Optional) Whether to enable the TRX to carry the main BCCH in the cell MRFD-210301Configuration Management Enumeration Type NO(No), YES(Yes)NO, YES None NO NO TRX None Read & Write Y Cell Less than 1 minute Each cell can be configured with only one TRX that carries the main BCCH.
IsMainBSC Is Main BSC BSC6900 SET BSCBASIC(Mandatory) Whether the BSC is a primary BSC GBFD-113726TC Pool Enumeration Type NO(No), YES(Yes)NO, YES None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ISMAINLOCGRP Is Main Locgrp BSC6900 ADD BTSLOCGRP(Mandatory) Whether this location group is the main location group. If the value is Yes, this location group is the main location group. If the value is No, this location group is the slave location group. GBFD-510104Multi-site Cell Enumeration Type NO(NO), YES(YES) NO, YES None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ISNC2SUPPORT NC2 support in external neighbour cell BSC6900 ADD GEXT2GCELL(Optional) A service support attribute of a cell, that is, whether an external GSM cell supports NC2 GBFD-116201Network-Controlled Cell Reselection (NC2) Enumeration Type NO(Not support), YES(Support) NO, YES None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ISNCMODE Subnetwork Configure Mode BSC6900 ADD NSE(Optional) Configuration mode of the IP subnetwork. Static configuration: fixed local NSVL and remote NSVL parameters through manual configuration; Dynamic configuration: the NSVL parameter obtained through negotiation between the BSC and the SGSN after the local NSVL and SGSN service point are configured manually. GBFD-118603Gb over IP Enumeration Type STATIC(Static), DYNAMIC(dynamic) STATIC, DYNAMIC None None None NSE None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
ISQOSPATH IS QOSPATH BSC6900 ADD IPMUX(Mandatory) Whether it is QOSPATH GBFD-118604GBFD-118610 Abis MUXUDP MUX for A Transmission Enumeration Type NO(NO), YES(YES) NO, YES None None None IP Path None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The parameter IPPATH must be configured in advance.
IsROOTNODE Is Root Node BSC6900 ADD ADJNODE(Mandatory) Whether to indicate it is the root node when the transport type is ATM or ATM_IP None None Enumeration Type NO(Not Root Node), YES(Root Node) NO, YES None None None Adjacent node When the value of "NODET" in "ADD ADJNODE" is set to IUB, IUR, or IUCS, and the value of "TRANST" in "ADD ADJNODE" is set to ATM or ATM_IP, this parameter is valid. Read & Write Not involved Not involved Not involved The parameter cannot be modified.
ISSPTBSCAISS Support BSC AISS BSC6900 ADD AISSCFG(Mandatory) Whether the Um interface software synchronization between BSCs is supported. GBFD-118201Soft-Synchronized Network Enumeration Type NO(NO), YES(YES) NO, YES None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None.
ISSPTDEMUS Demu Configure Information BSC6900 SET BTSENVALM(Mandatory) Whether multiple DEMUs are configured GBFD-111202O&M of BTS Enumeration Type YES(Configure), NO(Not Configure) YES, NO None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ISSUPPORTBTSLSWITCH Support BTS Local Switch BSC6900 SET BTSLSW(Optional) Whether to enable the BTS to support local switchingIf the BTS supports local switching, when the calling and called MSs are both within the BTS or BTS group, the voice signals are looped back to the MSs within the BTS or BTS group instead of being sent over the Abis interface to the BSC and MSC. In this way, the Abis resources between the convergence BTS and the BSC are released and saved. GBFD-117702BTS Local Switch Enumeration Type NO(No), YES(Yes)NO, YES None None None BTS This parameter can be set to YES only when "BssLsGenMode" in "SET BSSLS" is set to BTSPRIORITY, BSCPRIORITY, or BTSONLY. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ISSUPPORTFRA Support FRA BSC6900 ADD BRD(Optional) Whether to support the FRA (E1/T1 frame relay interface board) MRFD-210301Configuration Management Enumeration Type NO(NO), YES(YES) NO, YES None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IsSupportTcPool Is Support Tc Pool BSC6900 SET BSCBASIC(Optional) Whether to support the TC pool function GBFD-113726TC Pool Enumeration Type NO(No), YES(Yes)NO, YES None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ISTCBRD TC board BSC6900 ADD BRD(Mandatory) Whether it is a TC board MRFD-210301Configuration Management Enumeration Type YES(YES), NO(NO) YES, NO None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ISTCCENTRAL Remote TC Central BSC6900 ADD SUBRACK(Optional) Whether the subrack is a remote main TC subrack MRFD-210301Configuration Management Enumeration Type NO(NO), YES(YES) NO, YES None NO NO None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ISTMPCTRL DHEU Temperature Control BSC6900 SET BTSDHEUBP(Optional) Whether to control the temperature difference between the air inlet and air outlet and that between the air outlet and ambient by the temperature control system.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. GBFD-111202O&M of BTS Enumeration Type NO(NO), YES(YES) NO, YES None None NO BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ISTRANCABCON Tran. Cabinet Configured BSC6900 SET BTSPSUFP(Optional) Whether to configure the transmission cabinet. The BTS uses this parameter to calculate the number of TRXs to be shut down. GBFD-111202O&M of BTS Enumeration Type NOT_CONFIG(NOT CONFIGURED), CONFIG(CONFIGURED) NOT_CONFIG, CONFIG None NOT_CONFIGNone BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ITEM NCCELL No. BSC6900 SET GCELLIDLEFDDBA1(Mandatory)SET GCELLIDLETDDBA1(Mandatory)SET GCELL2GBA1(Mandatory)SET GCELLHO2GBA2(Mandatory)SET GCELLHOFDDBA2(Mandatory)SET GCELLHOTDDBA2(Mandatory) Number of a row to be changed in a BA list MRFD-210301Configuration Management Interval Type 1~64 1~64 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ITEMINDEX item index BSC6900 SET GCELLREV(Mandatory) Reserved parameter for cells. There are 30 parameters of this type, which can be used as new parameters in later versions. MRFD-210301Configuration Management Interval Type 1~30 1~30 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ITEMVALID Item Valid BSC6900 SET GCELLIDLEFDDBA1(Mandatory)SET GCELLIDLETDDBA1(Mandatory)SET GCELL2GBA1(Mandatory)SET GCELLHO2GBA2(Mandatory)SET GCELLHOFDDBA2(Mandatory)SET GCELLHOTDDBA2(Mandatory) Used for parameter control MRFD-210301Configuration Management Enumeration Type TRUE(Support), FALSE(Not Support) TRUE, FALSE None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ITEMVALUE value BSC6900 SET GCELLREV(Mandatory) Value of a reserved parameter for cells MRFD-210301Configuration Management Interval Type 0~65535 0~65535 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ITFT Interface Type BSC6900 ADD IPPATH(Mandatory)ADD ADJMAP(Mandatory)ADD TRMMAP(Mandatory) Interface type of resource transmission None None Enumeration Type IUB(Iub Interface), IUR(Iur Interface), IUCS(Iu-CS Interface), IUPS(Iu-PS Interface), ABIS(Abis Interface), A(A Interface), ATER(ATER Interface) IUB, IUR, IUCS, IUPS, ABIS, A, ATER None None None BSC6900None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
ITFType Interface Type BSC6900 ADD BTSIPRT(Mandatory) Type of an interface GBFD-118605IP QOS Enumeration Type PPP(PPP), MP(MP) PPP, MP None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IUCTHD IU max call barring ratio BSC6900 SET FCSW(Optional) Maximum traffic rate for restriction in the case of congestion on the IU interface. This parameter is valid only when "Board Class" is "XPU". WRFD-040100Flow Control Interval Type 0~100 0~100 None None 70 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IUFCSW IU flow control switch BSC6900 SET FCSW(Optional) Whether to control signaling traffic on the IU interface WRFD-040100Flow Control Enumeration Type ON, OFF ON, OFF None None ON Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IUO Concentric Attribute BSC6900 SET GTRXIUO(Mandatory) Concentric cell attributes of TRX. If the cell where a TRX is located is configured as a concentric cell, set this parameter to OVERLAID or UNDERLAID as required. If the cell where a TRX is located is not configured as a concentric cell, the default value of this parameter is NONE. GBFD-113201Concentric Cell Enumeration Type OVERLAID(Overlaid Subcell), UNDERLAID(Underlaid Subcell), NONE(None) OVERLAID, UNDERLAID, NONE None None None TRX This parameter is valid only when "IUOTP" in "MOD GCELL" is set to Concentric_cell. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IUOCHNTRAN Dynamic Channel Conversion Parameter of Concentric Cell BSC6900 SET GCELLPSCHM(Optional) Conversion policy of the dynamic channel of the concentric cell. GBFD-113201Concentric Cell Enumeration Type CONVERT0(Only convert at UL), CONVERT1(Only convert at OL), CONVERT2(UL first and convert allowed), CONVERT3(OL first and convert allowed) CONVERT0, CONVERT1, CONVERT2, CONVERT3 None None CONVERT0 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IUOHODURATIME UO HO Valid Time BSC6900 SET GCELLHOIUO(Optional) The triggering of concentric circle handovers must meet the P/N criteria, that is, when P out of N measurement reports meet the condition for concentric circle handovers, a concentric circle handover is triggered. This parameter corresponds to the P in the P/N criteria. GBFD-113201Concentric Cell Interval Type 0~16 0~16 s None 4 Cell The following condition must be met: "IUOHOSTATIME" >= "IUOHODURATIME". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IUOHOSTATIME UO HO Watch Time BSC6900 SET GCELLHOIUO(Optional) The triggering of concentric circle handovers must meet the P/N criteria, that is, when P out of N measurement reports meet the condition for concentric circle handovers, a concentric circle handover is triggered. This parameter corresponds to the N in the P/N criteria. GBFD-113201Concentric Cell Interval Type 0~16 0~16 s None 5 Cell The following condition must be met: "IUOHOSTATIME" >= "IUOHODURATIME". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IUOTP Cell IUO Type BSC6900 ADD GCELL(Optional) Whether a cell is a normal cell, concentric cell, or enhanced dual band network cell.In a concentric cell, the coverage areas of different TRXs form concentric circles of different radiuses.Owing to different coverage areas of the overlaid and underlaid parts, the two parts can be logically regarded as two cells. With many channels, the overlaid part is the major traffic bearer layer, recruiting most MSs in its coverage area. The underlaid part is used for coverage, providing services for the areas that the overlaid part cannot cover. The underlaid part covers the overlaid part, and thus the underlaid part can also share some traffic.An enhanced dual band network is amelioration to the existing dual band network. In such a network, two cells physically with a collocation site but different coverage areas form a cell group logically, namely, an inner cell and an extra cell. Channel resource sharing and cell load balancing is realized in the two cells through the algorithm of enhanced dual band network. GBFD-113201GBFD-114402 Concentric CellEnhanced Dual-Band Network Enumeration Type Normal_cell(Normal Cell), Concentric_cell(Concentric Cell), EDB_cell(Enhanced Double Frequency Cell) Normal_cell, Concentric_cell, EDB_cell None Normal_cell Normal_cell Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IURDLCTHD Iur downlink transfer control threshold BSC6900 SET FCCPUTHD(Optional) CPU usage threshold for Iur downlink flow control. When the average CPU usage of sliding windows reaches or exceeds the threshold, flow control is triggered on the Iur downlink. This parameter is valid only when "Board Class" is "XPU". WRFD-040100Flow Control Interval Type 30~100 30~100 per cent None 95 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IURDLCTHD Iur downlink transfer control threshold BSC6900 SET FCMSGQTHD(Optional) Packet queue usage threshold for Iur downlink flow control. When the average packet queue usage of sliding windows reaches or exceeds the threshold, flow control is triggered on the Iur downlink. This parameter is valid only when "Board Class" is "XPU". WRFD-040100Flow Control Interval Type 30~100 30~100 per cent None 75 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IURDLRTHD Iur downlink transfer restore threshold BSC6900 SET FCCPUTHD(Optional) CPU usage threshold for recovery from Iur downlink flow control. When the average CPU usage of sliding windows is lower than the threshold, flow control on the Iur downlink is stopped. This parameter is valid only when "Board Class" is "XPU". WRFD-040100Flow Control Interval Type 30~100 30~100 per cent None 85 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IURDLRTHD Iur downlink transfer restore threshold BSC6900 SET FCMSGQTHD(Optional) Packet queue usage threshold for recovery from Iur downlink flow control. When the average packet queue usage of sliding windows is lower than the threshold, flow control on the Iur downlink is stopped. This parameter is valid only when "Board Class" is "XPU". WRFD-040100Flow Control Interval Type 30~100 30~100 per cent None 65 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IURDLSW Iur downlink transfer flow control switch BSC6900 SET FCSW(Optional) Whether to control the traffic on the Iur downlink WRFD-040100Flow Control Enumeration Type ON, OFF ON, OFF None None ON Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IURGCTHD Iur-g control threshold BSC6900 SET FCCPUTHD(Optional) CPU usage threshold for Iur-g interface control. When the average CPU usage of sliding windows reaches or exceeds the threshold, resource auditing control is triggered. This parameter is valid only when "Board Class" is "XPU". WRFD-040100Flow Control Interval Type 30~100 30~100 per cent None 60 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IURGCTHD Iur-g control threshold BSC6900 SET FCMSGQTHD(Optional) Packet queue usage threshold for Iur-g interface. When the average packet queue usage of sliding windows reaches or exceeds the threshold, Iur-g interface flow control is triggered. This parameter is valid only when "Board Class" is "XPU". WRFD-040100Flow Control Interval Type 30~100 30~100 per cent None 75 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IURGRTHD Iur-g restore threshold BSC6900 SET FCCPUTHD(Optional) CPU usage threshold for recovery from Iur-g interface control. When the average CPU usage of sliding windows is lower than the threshold, Iur-g interface control is stopped. This parameter is valid only when "Board Class" is "XPU". WRFD-040100Flow Control Interval Type 30~100 30~100 per cent None 50 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IURGRTHD Iur-g restore threshold BSC6900 SET FCMSGQTHD(Optional) Packet queue usage threshold for recovery from Iur-g interface. When the average packet queue usage of sliding windows is lower than the threshold, Iur-g interface control is stopped. This parameter is valid only when "Board Class" is "XPU". WRFD-040100Flow Control Interval Type 30~100 30~100 per cent None 65 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IURGSW Iur-g flow control switch BSC6900 SET FCSW(Optional) Whether to control traffic on the Iur-g interface WRFD-040100Flow Control Enumeration Type ON, OFF ON, OFF None None ON Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IURULCTHD Iur uplink transfer control threshold BSC6900 SET FCCPUTHD(Optional) CPU usage threshold for Iur uplink flow control. When the average CPU usage of sliding windows reaches or exceeds the threshold, flow control is triggered on the Iur uplink. This parameter is valid only when "Board Class" is "XPU". WRFD-040100Flow Control Interval Type 30~100 30~100 per cent None 95 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IURULCTHD Iur uplink transfer control threshold BSC6900 SET FCMSGQTHD(Optional) Packet queue usage threshold for Iur uplink flow control. When the average packet queue usage of sliding windows reaches or exceeds the threshold, flow control is triggered on the Iur uplink. This parameter is valid only when "Board Class" is "XPU". WRFD-040100Flow Control Interval Type 30~100 30~100 per cent None 75 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IURULRTHD Iur uplink transfer restore threshold BSC6900 SET FCCPUTHD(Optional) CPU usage threshold for recovery from Iur uplink flow control. When the average CPU usage of sliding windows is lower than the threshold, flow control over on the Iur uplink is stopped. This parameter is valid only when "Board Class" is "XPU". WRFD-040100Flow Control Interval Type 30~100 30~100 per cent None 85 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IURULRTHD Iur uplink transfer restore threshold BSC6900 SET FCMSGQTHD(Optional) Packet queue usage threshold for recovery from Iur uplink flow control. When the average packet queue usage of sliding windows is lower than the threshold, flow control over on the Iur uplink is stopped. This parameter is valid only when "Board Class" is "XPU". WRFD-040100Flow Control Interval Type 30~100 30~100 per cent None 65 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
IURULSW Iur uplink transfer flow control switch BSC6900 SET FCSW(Optional) Whether to control the traffic on the Iur uplink WRFD-040100Flow Control Enumeration Type ON, OFF ON, OFF None None ON Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
J0ALMSWITCH J0 trace mismatch alarm switch BSC6900 SET OPT(Optional) Switch for the J0 tracing mark mismatching alarm None None Enumeration Type OFF(OFF), ON(ON) OFF, ON None None OFF Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
J0BYTE_FORMAT J0 Byte Format BSC6900 SET OPT(Mandatory) Byte display format of J0 None None Enumeration Type Hexadecimal(Hex decimal), Character_String(Character String) Hexadecimal, Character_String None Character_String Character_String None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
J0RXBYTE_FORMAT J0 Byte Format BSC6900 SET OPT(Mandatory) Byte display format of J0 None None Enumeration Type Hexadecimal(Hex decimal), Character_String(Character String) Hexadecimal, Character_String None Character_String Character_String None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
J0RXT J0 expected incept type BSC6900 SET OPT(Optional) Expected receiving type of J0 None None Enumeration Type NULL, 1byte, 16byte, 64byte NULL, 1byte, 16byte, 64byte None None 16byte Board None Read & Write Y BSC6900 If the mode is not consistent, will interrupt service until it is consistent. The setting of this parameter must be consistent with that on the peer.
J0RXVALUE J0 expected incept value BSC6900 SET OPT(Optional) Expected receiving value of J0 None None String Type None 0~124 characters None None SBS 155 Board None Read & Write Y BSC6900 If the mode is not consistent, will interrupt service until it is consistent. The setting of this parameter must be consistent with that on the peer.
J0TXBYTE_FORMAT J0 Byte Format BSC6900 SET OPT(Mandatory) Byte display format of J0 None None Enumeration Type Hexadecimal(Hex decimal), Character_String(Character String) Hexadecimal, Character_String None Character_String Character_String None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
J0TXT J0 transmit type BSC6900 SET OPT(Optional) Sending type of J0 None None Enumeration Type NULL, 1byte, 16byte, 64byte NULL, 1byte, 16byte, 64byte None None 16byte Board None Read & Write Y BSC6900 If the mode is not consistent, will interrupt service until it is consistent. The setting of this parameter must be consistent with that on the peer.
J0TXVALUE J0 transmit value BSC6900 SET OPT(Optional) Sending value of J0 None None String Type None 0~124 characters None None SBS 155 Board None Read & Write Y BSC6900 If the mode is not consistent, will interrupt service until it is consistent. The setting of this parameter must be consistent with that on the peer.
J0TYPE J0 type BSC6900 SET OPT(Optional) J0 type None None Enumeration Type 1byte, 16byte, 64byte 1byte, 16byte, 64byte None None 16byte Board None Read & Write Y BSC6900 If the mode is not consistent, will interrupt service until it is consistent. The setting of this parameter must be consistent with that on the peer.
J1ALMSWITCH J1 trace mismatch alarm switch BSC6900 SET OPT(Optional) Switch for the J1 tracing mark mismatching alarm None None Enumeration Type OFF(OFF), ON(ON) OFF, ON None None OFF Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
5/5/2014
Confidential Information of Huawei.
No Spreading without Permission
Page11of42
226347869.xls.ms_office Security Level:
J1BYTE_FORMAT J1 Byte Format BSC6900 SET OPT(Mandatory) Byte display format of J1 None None Enumeration Type Hexadecimal(Hex decimal), Character_String(Character String) Hexadecimal, Character_String none Character_String Character_String None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
J1RXBYTE_FORMAT J1 Byte Format BSC6900 SET OPT(Mandatory) Byte display format of J1 None None Enumeration Type Hexadecimal(Hex decimal), Character_String(Character String) Hexadecimal, Character_String none Character_String Character_String None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
J1RXT J1 expected incept type BSC6900 SET OPT(Optional) Expected receiving type of J1 None None Enumeration Type NULL, 1byte, 16byte, 64byte NULL, 1byte, 16byte, 64byte None None 16byte Board None Read & Write Y BSC6900 If the mode is not consistent, will interrupt service until it is consistent. The setting of this parameter must be consistent with that on the peer.
J1RXVALUE J1 expected incept value BSC6900 SET OPT(Optional) Expected receiving value of J1 None None String Type None 0~124 characters None None SBS 155 Board None Read & Write Y BSC6900 If the mode is not consistent, will interrupt service until it is consistent. The setting of this parameter must be consistent with that on the peer.
J1TXBYTE_FORMAT J1 Byte Format BSC6900 SET OPT(Mandatory) Byte display format of J1 None None Enumeration Type Hexadecimal(Hex decimal), Character_String(Character String) Hexadecimal, Character_String None Character_String Character_String None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
J1TXT J1 transmit type BSC6900 SET OPT(Optional) Sending type of J1 None None Enumeration Type NULL, 1byte, 16byte, 64byte NULL, 1byte, 16byte, 64byte None None 16byte Board None Read & Write Y BSC6900 If the mode is not consistent, will interrupt service until it is consistent. The setting of this parameter must be consistent with that on the peer.
J1TXVALUE J1 transmit value BSC6900 SET OPT(Optional) sending value of J1 None None String Type None 0~124 characters None None SBS 155 Board None Read & Write Y BSC6900 If the mode is not consistent, will interrupt service until it is consistent. The setting of this parameter must be consistent with that on the peer.
J1TYPE J1 type BSC6900 SET OPT(Optional) J1 type None None Enumeration Type 1byte, 16byte, 64byte 1byte, 16byte, 64byte None None 16byte Board None Read & Write Y BSC6900 If the mode is not consistent, will interrupt service until it is consistent. The setting of this parameter must be consistent with that on the peer.
J2ALMSWITCH J2 mismatch alarm switch BSC6900 SET COPTLNK(Optional) Switch for the J2 tracing mark mismatching alarm None None Enumeration Type OFF(OFF), ON(ON) OFF, ON None None OFF Channelized optical port None Read & Write N (No impact on the UE in idle mode) Not involved Not involved It is used for interworking with products of other manufacturers.
J2BYTE_FORMAT J2 Byte Format BSC6900 SET COPTLNK(Optional) Byte display format of J2 None None Enumeration Type Hexadecimal(Hex decimal), Character_String(Character String) Hexadecimal, Character_String None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
J2MODE J2 length BSC6900 SET COPTLNK(Optional) Byte length of J2 None None Enumeration Type NULL, 1BYTE, 16BYTE, 64BYTE NULL, 1BYTE, 16BYTE, 64BYTE None None None Channelized optical port None Read & Write N (No impact on the UE in idle mode) Not involved Not involved 1. This command is applicable to the boards AOUa, POUa, AOUc, POUc, and OIUa.2. It is used for interworking with products of other manufacturers.
J2RXVALUE J2 expected incept value BSC6900 SET COPTLNK(Optional) Expected receiving value of J2 None None String Type None 0~64 characters None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
J2TXVALUE J2 transmit value BSC6900 SET COPTLNK(Optional) Sending value of J2 None None String Type None 0~64 characters None None None Channelized optical port None Read & Write N (No impact on the UE in idle mode) Not involved Not involved 1. This command is applicable to the boards AOUa and POUa.2. It is used for interworking with products of other manufacturers.
JAUTOADD automatic append J byte BSC6900 SET OPT(Optional)SET COPTLNK(Optional) A zero or a space used to fill in the J byte of the optical port based on the J byte of the peer equipment. If the J bytes are inconsistent, an alarm related to J byte mismatch will be reported and the negotiation of the optical port may fail, thus leading to deterioration of the services. None None Enumeration Type ZERO(zero), SPACE(space) ZERO, SPACE None None SPACE Board None Read & Write Y Optical port If the mode is not consistent, will interrupt service until it is consistent. The setting of this parameter must be negotiated with that on the interconnected side.
JBF LAPD Jitter Buffer Algorithm BSC6900 SET BTSJBF(Mandatory) Whether to enable the LAPD Jitter Buffer algorithm. This algorithm adds a buffering adaptation layer under the LAPD layer at the receiving end. The function at this layer is to delay the I frame (first received, last sent) currently received. If an I frame is received within the delayed duration, the frame is sent to the LAPD layer. In this way, the frame disorder is avoided. GBFD-118401Abis Transmission Optimization Enumeration Type DISABLE(Disable), ENABLE(Enable) DISABLE, ENABLE None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
JITBUFSWITCH Jitter Buffer switch BSC6900 SET OTHSOFTPARA(Optional) Whether the LAPD Jitter Buffer is enabled on the BSC side GBFD-118601Abis over IP Enumeration Type DENY(Deny), ALLOW(Allow) DENY, ALLOW None None When the disorder phenomenon is severe in the IP network, the recommended value is ALLOW; when there is no or little disordered packets, you are recommended to set this parameter to DENY to avoid extra transmission delay. BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
K2MODE K2 Mode BSC6900 SET MSP(Optional) Determines whether the last three bits of K2 indicates the single end and the dual end GBFD-111701Board Switchover Enumeration Type NOT-INDICATE-END(NOT-INDICATE-END), INDICATE-END(INDICATE-END) NOT-INDICATE-END, INDICATE-END None None None MSP protect group None Read & Write Y BSC6900 Interrupt the service until negotiate successfully again. The setting of this parameter must be negotiated with that on the interconnected side.
KBIAS K Bias BSC6900 SET GCELLHOAD(Optional) K offset used in K sequencing. To reduce ping-pong handovers, the system performs K sorting based on the downlink receive level of the candidate cells. But before doing that, the system subtracts "K Bias" from the actual downlink receive level of the candidate cells. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 0~63 0~63 dB None 0 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
KEEPALIVE Keep-alive timer length[S] BSC6900 ADD PPPLNK(Optional)ADD MPLNK(Optional) Duration of the PPP/MP link keep-alive timer GBFD-118611GBFD-118622 Abis IP over E1/T1A IP over E1/T1 Interval Type 1~30 1~30 s 2 2 PPP link None Read & Write Y BSC6900 Interrupt the service until negotiate successfully again. None
LAC Cell LAC BSC6900 ADD GCELL(Mandatory)ADD GEXT2GCELL(Mandatory)ADD GEXT3GCELL(Mandatory)SET FHO(Mandatory)ADD GCELLQUICKSETUP(Mandatory)ADD BTSAUTOPLAN(Mandatory)SET BTSAUTOPLANCFG(Optional) Location area code (LAC). MSs can freely move in the local location area with no need of location update. Reasonable local allocation can effectively lighten the signaling load and improve the call completion rate. MRFD-210301Configuration Management Interval Type 1~65533,65535 1~65533, 65535 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The LAC can be input in hexadecimal format. The hexadecimal format is H'****, for example, H'1214.
LAC1 Cell LAC BSC6900 SET BTSAUTOPLANCFG(Optional) Location area code (LAC). The MS can move within the local location area without location update. The reasonable classification of the location area is very important for reducing the signaling load and improving the put-through rate. GBFD-510702Compact BTS Automatic Capacity Planning Interval Type 1~65533,65535 1~65533, 65535 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LACPMODE Aggregation Mode BSC6900 ADD ETHTRK(Mandatory) Aggregation mode. When this parameter is set to static aggregation, the LACP protocol is activated; otherwise, the LACP protocol is deactivated. MRFD-210103Link aggregation Enumeration Type STATIC_LACP, MANUAL_AGGREGATION STATIC_LACP, MANUAL_AGGREGATION None None None Ethernet port None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
LATIDECI Latitude Decimal Part BSC6900 SET GCELLLCS(Mandatory) Decimal value when the latitude where a cell is located is indicated in the format of degree GBFD-115402BSS-Based LCS (Cell ID + TA) String Type None 1~5 characters degreeNone None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LATIDEGREE Latitude Degree Part BSC6900 SET GCELLLCS(Mandatory) Decimal value when the longitude where a cell is located is indicated in the format of degree GBFD-115402BSS-Based LCS (Cell ID + TA) Interval Type 0~90 0~90 degreeNone None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LATIINT Latitude Int Part BSC6900 SET GCELLLCS(Mandatory) Integer value when the latitude where a cell is located is indicated in the format of degree GBFD-115402BSS-Based LCS (Cell ID + TA) Interval Type 0~90 0~90 degreeNone None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LATIMINUTE Latitude Minute Part BSC6900 SET GCELLLCS(Mandatory) Value of the minute part when the latitude is indicated in the format of degree_minute_second GBFD-115402BSS-Based LCS (Cell ID + TA) Interval Type 0~59 0~59 minuteNone None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LATISECONDDECI Latitude Second Decimal Part BSC6900 SET GCELLLCS(Mandatory) Decimal value of the second part when the latitude is indicated in the format of degree_minute_second GBFD-115402BSS-Based LCS (Cell ID + TA) Interval Type 0~9 0~9 secondNone None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LATISECONDINT Latitude Second Int Part BSC6900 SET GCELLLCS(Mandatory) Integer value of the second part when the latitude is indicated in the format of degree_minute_second GBFD-115402BSS-Based LCS (Cell ID + TA) Interval Type 0~59 0~59 secondNone None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LATPRD Delay measure period [100ms] BSC6900 ADD IPLOGICPORT(Optional) Delay statistics period. This parameter indicates the period to collect the statistics information about the link transmission delay. Note that the unit of this parameter is 100 milliseconds. The actual delay statistics period is the value of this parameter multiplied by 100 milliseconds. None None Interval Type 1~100 100~10000, step:100 ms 2 2 IP logical port None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LATSUSTM Delay adjust suspend period [LATTH] BSC6900 ADD IPLOGICPORT(Optional) Number of delay adjustment suspension periods. This parameter specifies the delay statistics periods in which the bandwidth is not adjusted when the bandwidth adjustment function of the logical port is triggered due to the change of the link transmission delay. This parameter can be used to control the rate of the bandwidth adjustment at the logical port. None None Interval Type 0~100 0~100 None 4 4 IP logical port None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LATTH Rate down threshold for delay [ms] BSC6900 ADD IPLOGICPORT(Optional) Bandwidth reduction delay threshold. This parameter is used to trigger the function of bandwidth reduction at the logical port when the link delay exceeds the value of this parameter. None None Interval Type 0~10000 0~10000 ms 25 25 IP logical port None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LATUDK average delay down filter mantissa BSC6900 ADD IPLOGICPORT(Optional) Average delay reduction filtering index None None Interval Type 0~15 0~15 None 3 3 IP logical port None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LATUPK average delay up filter mantissa BSC6900 ADD IPLOGICPORT(Optional) Average delay increase filtering index None None Interval Type 0~15 0~15 None 8 8 IP logical port None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LAYER Layer of the cell BSC6900 SET GCELLBASICPARA(Optional) Layer where a cell is located. The network designed by Huawei has four layers: Umbrella(4 layer), Macro(3 layer), Micro(2 layer), and Pico(1 layer). Each layer can be set with 16 priorities. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Enumeration Type 1, 2, 3, 4 1, 2, 3, 4 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LAYER Layer of the cell BSC6900 ADD GEXT2GCELL(Optional) A network basically consists of four layers, namely, Umbrella, Macro, Micro, and Pico. Cell priorities influence the sorting of neighboring cells during handovers as well as handover algorithms including PBGT and inter-layer handovers. For example, PBGT handovers can only occur among cells on a same layer and of a same priority level. If you assign different layers and priorities to a 1800-M cell and a 900-M cell, PBGT handovers from the 1800-M cell to the 900-M cell will not occur. This causes slow handovers even when the receive quality is good. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Enumeration Type 1, 2, 3, 4 1, 2, 3, 4 None None None Cell There are four network layers, that is, layer 1 to layer 4. A lower layer No. indicates a higher priority. The cell priority is determined by both the network layer and the "PRIOR" parameter. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LcsSupportControl LCS Support Control BSC6900 SET AITFOTHPARA(Optional) Whether to support the LCS function. This function needs the support of the MSC. Therefore, this parameter must be properly set according to the supporting capacity of the MSC. GBFD-115402BSS-Based LCS (Cell ID + TA) Enumeration Type NO(No), YES(Yes)NO, YES None None None MSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The setting of this parameter needs negotiation with the opposite network element MSC.
LDRFOUH LDR Fourth BSC6900 SET LDR(Optional)Fourth action taken for load control GBFD-118601Abis over IP Enumeration Type CLOSE(Close), PSDOWN(PS Downspeeding), AMRC(AMRC), CSPH(CS Preference TCHH), CSFHHO(CS TCHF-TCHH HO) CLOSE, PSDOWN, AMRC, CSPH, CSFHHO None None None BSC6900If this parameter is not set to CLOSE, it value must not be the same as "LDRSND", "LDRTRD", or "LDRFST". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LDRFST LDR First BSC6900 SET LDR(Optional)First action taken for load control GBFD-118601Abis over IP Enumeration Type CLOSE(Close), PSDOWN(PS Downspeeding), AMRC(AMRC), CSPH(CS Preference TCHH), CSFHHO(CS TCHF-TCHH HO) CLOSE, PSDOWN, AMRC, CSPH, CSFHHO None None None BSC6900If this parameter is not set to CLOSE, it value must not be the same as "LDRSND", "LDRTRD", or "LDRFOUH". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LDRSND LDR Second BSC6900 SET LDR(Optional)Second action taken for load control GBFD-118601Abis over IP Enumeration Type CLOSE(Close), PSDOWN(PS Downspeeding), AMRC(AMRC), CSPH(CS Preference TCHH), CSFHHO(CS TCHF-TCHH HO) CLOSE, PSDOWN, AMRC, CSPH, CSFHHO None None None BSC6900If this parameter is not set to CLOSE, it value must not be the same as "LDRFST", "LDRTRD", or "LDRFOUH". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LEIBRZ Bronze user Load EQ index BSC6900 ADD ADJMAP(Mandatory) Bronze user load EQ index used by the current adjacent node None None Interval Type 0~63 0~63 None None None Adjacent node The load EQ table index is configured by setting the value of "LEI" in "ADD LOADEQ". Read & Write N (No impact on the UE in idle mode) Not involved Not involved The load EQ table is configured already.
LEIGLD Gold user Load EQ index BSC6900 ADD ADJMAP(Mandatory) Gold user load EQ index used by the current adjacent node None None Interval Type 0~63 0~63 None None None Adjacent node The load EQ table index is configured by setting the value of "LEI" in "ADD LOADEQ". Read & Write N (No impact on the UE in idle mode) Not involved Not involved The load EQ table is configured already.
LEISLV Silver user Load EQ index BSC6900 ADD ADJMAP(Mandatory) Silver user load EQ index used by the current adjacent node None None Interval Type 0~63 0~63 None None None Adjacent node The load EQ table index is configured by setting the value of "LEI" in "ADD LOADEQ". Read & Write N (No impact on the UE in idle mode) Not involved Not involved The load EQ table is configured already.
LENO Local entity No. BSC6900 ADD M3LE(Mandatory)ADD M3DE(Mandatory) Local entity No. of identifying a unique entity. None None Interval Type 0~182 0~182 None None None BSC6900None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
LEVEL Log Level BSC6900 EXP LOG(Optional) Level of the logGBFD-111203MRFD-210305 O&M of BSCSecurity Management Enumeration Type CRITICAL(Critical), MAJOR(Major), MINOR(Minor) CRITICAL, MAJOR, MINOR None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LEVEL Log Level BSC6900 COL LOG(Optional) Log level to be collected. GBFD-111203O&M of BSC Enumeration Type INFO(Information Level), WARN(Warn level), ERR(Error Level), AST(Assert Level) INFO, WARN, ERR, AST None None None RNC None Read & Write Not involved Not involved Not involved None
LEVEL Alarm Mask Switch BSC6900 SET ALMML(Mandatory) alarm mask switch. None None Enumeration Type ON, OFF ON, OFF None None ON BSC6900None Read & Write Not involved Not involved Not involved None
LEVEL Log Level BSC6900 SET LOGCFG(Optional) Log Level MRFD-210304Faulty Management Enumeration Type MAJOR~1MINOR~2MESSAGE~4DEBUG MAJOR~1MINOR~2MESSAGE~4DEBUG~8 None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
Level MD LEVEL BSC6900 ADD ETHMD(Optional) Class of the maintenance domain GBFD-118630Ethernet OAM Interval Type 0~7 0~7 None 0 0 Ethernet port None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
LEVELRPT Level Report Switch BSC6900 SET GCELLBASICPARA(Optional) Whether to support reporting the main diversity level GBFD-110801GBFD-110802 Processing of Measurement ReportPre-processing of Measurement Report Enumeration Type NO(Not Support), YES(Support), NONE(Invalid) NO, YES, NONE None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LEVHOEN Level HO Allowed BSC6900 SET GCELLHOBASIC(Optional) Whether to allow inter-layer and inter-level handovers. The inter-layer and inter-level handover algorithm is achieved through the setting of different layers and priorities for cells, which switches traffic to cells of a higher precedence (decided by "Layer of the cell" and "Cell priority" together). GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Enumeration Type NO(No), YES(Yes)NO, YES None None YES Cell This parameter is valid only when "HOCTRLSWITCH" is set to HOALGORITHM1. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LEVHOHYST Inter-layer HO Hysteresis BSC6900 SET GCELLHOBASIC(Optional) Hysteresis value during the handovers between cells on different layers or of different priorities. This value is used to suppress inter-layer ping-pong handovers. Inter-layer handover threshold of the serving cell = "Inter-layer HO threshold" - "Inter-layer HO Hysteresis"; Inter-layer handover threshold of a neighboring cell = "Inter-layer HO threshold" + "Adjacent Cell Inter-layer HO Hysteresis" - 64. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 0~63 0~63 dB None 2 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LEVLAST Layer HO Valid Time BSC6900 SET GCELLHOBASIC(Optional) The triggering of inter-layer handovers must meet the P/N criteria, that is, when the condition for inter-layer handovers is met for a consecutive P seconds during N seconds, an inter-layer handover is triggered. This parameter corresponds to the P in the P/N criteria. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 1~16 1~16 s None 2 Cell This parameter is valid only when "HOCTRLSWITCH" is set to HOALGORITHM1 and "LEVHOEN" is set to YES. The following condition must be met: "LEVSTAT" >= "LEVLAST". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LEVSTAT Layer HO Watch Time BSC6900 SET GCELLHOBASIC(Optional) The triggering of inter-layer handovers must meet the P/N criteria, that is, when the condition for inter-layer handovers is met for a consecutive P seconds during N seconds, an inter-layer handover is triggered. This parameter corresponds to the N in the P/N criteria. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 1~16 1~16 s None 3 Cell This parameter is valid only when "HOCTRLSWITCH" is set to HOALGORITHM1 and "LEVHOEN" is set to YES. The following condition must be met: "LEVSTAT" >= "LEVLAST". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LGCAPPTYPE Logic function type BSC6900 LOD PATCH(Optional)CON PATCH(Optional) Logic function type of the board MRFD-210301Configuration Management Enumeration Type TDM_Switching, GCP, UCP, RGCP, RUCP, IBCA, GTC, GPCU, UUP, ATM, IP, FR, HDLC, TDM, GbIP, Abis_TDM, Ater_TDM, Pb_TDM, A_TDM, Abis_IP TDM_Switching, GCP, UCP, RGCP, RUCP, IBCA, GTC, GPCU, UUP, ATM, IP, FR, HDLC, TDM, GbIP, Abis_TDM, Ater_TDM, Pb_TDM, A_TDM, Abis_IP None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LGCAPPTYPE Logic function type BSC6900 ADD BRD(Optional) Logic function type of the boardOAM:Operation And Maintenance ProcessTDM_Switching:TDM switching processGCP:GSM BSC Control plane ProcessUCP:UMTS RNC Control plane ProcessRGCP:Resource Management and GSM BSC Control plane ProcessRUCP:Resource Management and UMTS RNC Control plane ProcessIBCA:Interference Based Channel AllocationGTC:GSM BSC TC ProcessGPCU:GSM BSC PCU ProcessUUP:UMTS RNC User plane ProcessATM:AEUa/ATM ATM over E1/T1/J1 interface,AOUa/ATM ATM over channelized Optical STM-1/OC-3 interface,AOUc/ATM ATM over channelized Optical STM-1/OC-3 interface,UOIa/ATM ATM over Unchannelized Optical STM-1/OC-3 interface,UOIc/ATM ATM over Unchannelized Optical STM-1/OC-3 interfaceIP:GOUc/IP IP over GE Optical interface,GOUa/IP IP over GE Optical interface,PEUa/IP IP over E1/T1/J1 interface,FG2c/IP IP over FE/GE interface,FG2a/IP IP over FE/GE interface,POUc/IP IP over channelized Optical STM-1/OC-3 interface,POUa/IP IP over channelized Optical STM-1/OC-3 interface,UOIa/IP IP over Unchannelized MRFD-210301Configuration Management Enumeration Type OAM, TDM_Switching, GCP, UCP, RGCP, RUCP, IBCA, GTC, GPCU, UUP, ATM, IP, FR, HDLC, TDM, GbIP, Abis_TDM, Ater_TDM, Pb_TDM, A_TDM, Abis_IP, SAU OAM, TDM_Switching, GCP, UCP, RGCP, RUCP, IBCA, GTC, GPCU, UUP, ATM, IP, FR, HDLC, TDM, GbIP, Abis_TDM, Ater_TDM, Pb_TDM, A_TDM, Abis_IP, SAU None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LGCAPPTYPE Logic function type BSC6900 ADD PPPLNK(Mandatory)ADD MPGRP(Mandatory) Logical function type GBFD-118611GBFD-118622 Abis IP over E1/T1A IP over E1/T1 Enumeration Type IP, Abis_IP IP, Abis_IP None None None Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LGCUSAGETYPE Application type of Pouc_TDM BSC6900 ADD BRD(Optional) Application type of the PoucTDM board MRFD-210301Configuration Management Enumeration Type A/Gb, Abis/Ater/Pb/Gb A/Gb, Abis/Ater/Pb/GbNone None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LGIDX PbSL Logical Index BSC6900 ADD PBSL(Optional) The Logical Index of PB signaling link. GBFD-111203O&M of BSC Interval Type 5120~5183 5120~5183 None None None None None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
LHUMTHD Lower Humidity Threshold BSC6900 SET BTSEXD(Optional) Lower humidity threshold for the environment alarm box to report an alarm indicating that the ambient humidity is too low. If the ambient humidity of the BTS is lower than this threshold, the environment alarm box reports the alarm.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. GBFD-111202O&M of BTS Interval Type 0~99 0~99 None None 10 BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter must be less than "UHUMTHD".
LICALMCTHD Alarm occur threshold BSC6900 SET LICALMTHD(Mandatory) The occur threshold of 20258 alarm,you can set it from 90% to 99% MRFD-210304Faulty Management Interval Type 90~99 90~99 per cent None 90 None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LICALMRTHD Alarm recover threshold BSC6900 SET LICALMTHD(Mandatory) The recover threshold of 20258 alarm,you can set it from 90% to 99% MRFD-210304Faulty Management Interval Type 70~95 70~95 per cent None 70 None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LINKNO Link No. BSC6900 LOP LAPDLNK(Mandatory) It is the key field of identifying one LAPD link. GBFD-111203O&M of BSC Interval Type 0~25599 0~25599 None None None LAPDLNKNone Read & Write Not involved Not involved Not involved The parameter cannot be modified.
LISTTYPE Query Type BSC6900 EXP GCELLTEMPLATE(Optional) Type of the parameters to be displayed when a cell template is queried. The value "DIFFERENCE" indicates that the parameters in the cell template that are different from those in the default template are displayed. The value "ALL" indicates that all the parameters in the cell template are displayed. None None Enumeration Type DIFFERENCE, ALLDIFFERENCE, ALL None DIFFERENCE DIFFERENCE None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LKTATE Link rate type BSC6900 ADD MTP3LNK(Optional) Rate type of the designated link. None None Enumeration Type 64K(64Kbit/s), 2M(2Mbit/s) 64K, 2M bit/s 64K 64K MTP3 linkNone Read & Write Not involved Not involved Not involved The parameter cannot be modified.
LL Lower Limit BSC6900 SET ALMPORT(Optional) Lower limit for triggering an alarm MRFD-210304Faulty Management String Type None 0~9 characters None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LL Lower Limit BSC6900 SET BTSENVALMPORT(Optional) Lower limit of an alarm. It is valid for the analog port. MRFD-210301Configuration Management String Type None 1~8 characters None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LLCN Channel No. BSC6900 SET E1T1LOP(Optional) The loopback channel number when the port loopback mode is set to single channel local loopback None None Enumeration Type TS1(Time_slot_1), TS2(Time_slot_2), TS3(Time_slot_3), TS4(Time_slot_4), TS5(Time_slot_5), TS6(Time_slot_6), TS7(Time_slot_7), TS8(Time_slot_8), TS9(Time_slot_9), TS10(Time_slot_10), TS11(Time_slot_11), TS12(Time_slot_12), TS13(Time_slot_13), TS14(Time_slot_14), TS15(Time_slot_15), TS16(Time_slot_16), TS17(Time_slot_17), TS18(Time_slot_18), TS19(Time_slot_19), TS20(Time_slot_20), TS21(Time_slot_21), TS22(Time_slot_22), TS23(Time_slot_23), TS24(Time_slot_24), TS25(Time_slot_25), TS26(Time_slot_26), TS27(Time_slot_27), TS28(Time_slot_28), TS29(Time_slot_29), TS30(Time_slot_30), TS31(Time_slot_31) TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10, TS11, TS12, TS13, TS14, TS15, TS16, TS17, TS18, TS19, TS20, TS21, TS22, TS23, TS24, TS25, TS26, TS27, TS28, TS29, TS30, TS31 None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LNA1 LNAThreshold1 BSC6900 SET BTSRXUBP(Optional) Upper threshold of the low noise amplifier. When the working voltage of the low noise amplifier attenuator in the RXU board is smaller than this value, an alarm is reported by the BTS. GBFD-111202O&M of BTS Interval Type 0~40 0~40 V 35 None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LNA2 LNAThreshold2 BSC6900 SET BTSRXUBP(Optional) Lower threshold of the low noise amplifier. When the working voltage of the low noise amplifier attenuator in the RXU board is greater than this value, an alarm is reported by the BTS. GBFD-111202O&M of BTS Interval Type 40~80 40~80 V 45 None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LNKNUMMODE Tributary Numbering BSC6900 SET OPT(Optional) Optical interface branch numbering method None None Enumeration Type LUCENT_MODE, HUAWEI_MODE, ALCATEL_MODE LUCENT_MODE, HUAWEI_MODE, ALCATEL_MODE None None None Board None Read & Write Y BSC6900 Interrupt the service until negotiate successfully again. The setting of this parameter must be consistent with that on the peer.
LNKRATE Semilink Rate BSC6900 ADD SEMILINK(Optional) Rate of the Semilink. GBFD-114701Semi-Permanent Connection Enumeration Type 8K(8Kbit/s), 16K(16Kbit/s), 32K(32Kbit/s), 64K(64Kbit/s), 2M(2Mbit/s) 8K, 16K, 32K, 64K, 2MNone None None BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LNKREDFLAG Initial bearing traffic active tag BSC6900 ADD M3LNK(Optional) Initial bearing tag of the M3UA link. Only the active mode and standby mode are available. For the relevant bearer tag, see the RFC4666. None None Enumeration Type M3UA_MASTER_MOD(M3UA_MASTER_MOD), M3UA_SLAVE_MOD(M3UA_SLAVE_MOD) M3UA_MASTER_MOD, M3UA_SLAVE_MOD None M3UA_MASTER_MOD M3UA_MASTER_MODBSC6900None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
LNKSLSMASK Signalling link mask BSC6900 ADD MTP3LKS(Optional) Link load sharing. In the value, the number of 1s (represented by n) determines the maximum number (2) of links for the load sharing. For example, B0000 indicates that up to one link is used for the load sharing, B0001 and B1000 indicate that up to two links are used for the load sharing. The additional links are not used for the load sharing. The AND operation between this value and " signaling route mask " in the N7DPC is equal to 0. None None Enumeration Type B0000(B0000), B0001(B0001), B0010(B0010), B0011(B0011), B0100(B0100), B0101(B0101), B0110(B0110), B0111(B0111), B1000(B1000), B1001(B1001), B1010(B1010), B1011(B1011), B1100(B1100), B1101(B1101), B1110(B1110), B1111(B1111) B0000, B0001, B0010, B0011, B0100, B0101, B0110, B0111, B1000, B1001, B1010, B1011, B1100, B1101, B1110, B1111 None B1111 B1111 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved According to the MTP3 load sharing principle, the link selection mask must be set properly. If the value is not set properly, the load sharing between MTP3 links may fail.
LNKSLSMASK Signalling link mask BSC6900 ADD M3LKS(Optional) Signaling link mask corresponding to the M3UA link set. It is used for the M3UA link load sharing. In the value, the number of 1s (represented by n) determines the maximum number (2) of links for the load sharing. For example, B0000 indicates that up to one link is used for the load sharing, B0001 and B0002 indicate that up to two links are used for the load sharing. The additional links are not used for the load sharing. The AND operation between this value and " signaling route mask " in the "ADD N7DPC" is equal to 0. None None Enumeration Type B0000(B0000), B0001(B0001), B0010(B0010), B0011(B0011), B0100(B0100), B0101(B0101), B0110(B0110), B0111(B0111), B1000(B1000), B1001(B1001), B1010(B1010), B1011(B1011), B1100(B1100), B1101(B1101), B1110(B1110), B1111(B1111) B0000, B0001, B0010, B0011, B0100, B0101, B0110, B0111, B1000, B1001, B1010, B1011, B1100, B1101, B1110, B1111 None B1111 B1111 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The mask is calculated according to the link set to a destination entity.
LoadAccThres Load handover Load Accept Threshold BSC6900 ADD GEXT2GCELL(Optional)ADD GEXT3GCELL(Optional)SET GCELLHOAD(Optional) When the load of a cell is lower than this parameter, the cell can serve users switched over from other cells due to load handovers; otherwise, the cell will not serve users switched over from other cells due to load handovers. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 0~100 0~100 per cent None 80 Cell This parameter is valid only when "LoadHoEn" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LOADBALANCEALG MSC Pool Load Balancing Algorithm Select BSC6900 ADD GCNOPERATOR(Optional) Type of load balancing algorithm of the MSC Pool. Generally, the BSC chooses an MSC according to the obtained network resource indication (NRI). In some cases, however, the BSC cannot do so. Instead, the BSC chooses a target MSC according to a load balancing algorithm. GBFD-117401MSC Pool Enumeration Type RANDOMALG(Random Algorithm), OTHERALG(MS ID Algorithm) RANDOMALG, OTHERALG None RANDOMALGRANDOMALG MSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LOADBROADCASTPERIOD NC2 Load Broadcast Period BSC6900 SET BSCPSSOFTPARA(Optional) Period to send the load broadcast. GBFD-116201Network-Controlled Cell Reselection (NC2) Interval Type 1~10 1~10 s None 4 BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter is valid only when "NC2LoadResel" is set to SUPPORT.
LOADCURRENTDIV Load Current Shunt Coefficient BSC6900 SET BTSPMUBP(Optional) Load current shunt coefficient GBFD-111202O&M of BTS Interval Type 0~1000 0~1000 None 100 None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LoadHoEn Load Handover Support BSC6900 SET GCELLHOBASIC(Optional) This parameter specifies whether a traffic load-sharing handover is enabled. The load handover helps to reduce cell congestion, improve success rate of channel assignment, and balance the traffic load among cells, thus improving the network performance. The load handover is used as an emergency measure instead of a primary measure to adjust abnormal traffic burst in partial areas. If load handovers occur frequently in a partial area, the cell and TRX configuration of BTSs and the network layout should be adjusted. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Enumeration Type NO(No), YES(Yes)NO, YES None None NO Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LoadHoEnExt2G Load Handover Support BSC6900 ADD GEXT2GCELL(Optional) Indicates that if a 2G neighboring cell supports load handovers, the BSC adds the load information of the local cells in the signaling procedures related to this neighboring cell. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Enumeration Type NO(No), YES(Yes)NO, YES None None NO Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LoadHoEnExt3G Load Handover Support BSC6900 ADD GEXT3GCELL(Optional) Indicates that if a 3G neighboring cell supports load handovers, the BSC adds the load information of the local cells in the signaling procedures related to this neighboring cell. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Enumeration Type NO(No), YES(Yes)NO, YES None None NO Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LOADHOPENTIME Penalty time on load HO BSC6900 SET GCELLHOFITPEN(Optional) After a load handover succeeds, the BSC punishes the former serving cell during "Penalty time on load HO" by subtracting "Penalty value on load HO" from the receive level of the former serving cell, thus avoiding ping-pong handovers. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 0~255 0~255 s None 10 Cell This parameter is valid only when "HOCTRLSWITCH" in "SET GCELLHOBASIC" is set to HOALGORITHM2. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LOADHOPENVALUE Penalty value on load HO BSC6900 SET GCELLHOFITPEN(Optional) After a load handover succeeds, the BSC punishes the former serving cell during "Penalty time on load HO" by subtracting "Penalty value on load HO" from the receive level of the former serving cell, thus avoiding ping-pong handovers. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 0~63 0~63 dB None 63 Cell This parameter is valid only when "HOCTRLSWITCH" in "SET GCELLHOBASIC" is set to HOALGORITHM2. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LOADHOPERIOD Load HO Step Period BSC6900 SET GCELLHOAD(Optional) When the load of a cell reaches or exceeds "Load HO Threshold", all the calls that are using this cell as the serving cell generate handover requests at the same time, which will suddenly increase the load of the processor. Under some circumstances, congestion occurs in the cell, which will result in call drop. To solve this problem, the BSC uses the hierarchical load handover algorithm to control the number of users included in each level of handovers. This parameter indicates the duration of each handover level. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 1~255 1~255 s None 10 Cell This parameter is valid only when "LOADHOEN" in "SET GCELLHOBASIC" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LOADHOSTEP Load HO Step Level BSC6900 SET GCELLHOAD(Optional) In hierarchical load handovers, starting from "Edge HO DL RX_LEV Threshold", a "Load HO Step Level" is added to the upper handover threshold after every "Load HO Step Period". In this way, all the calls in the current serving cell whose receive level is in the range "Edge HO DL RX_LEV Threshold" to "Edge HO DL RX_LEV Threshold" + "Load HO Bandwidth" are switched to other cells. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 1~63 1~63 dB None 5 Cell This parameter is valid only when "LOADHOEN" in "SET GCELLHOBASIC" is set to YES. The value of this parameter must be smaller than "LOADOFFSET". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LOADOFFSET Load HO Bandwidth BSC6900 SET GCELLHOAD(Optional) In the handover algorithm of the first generation, load handovers can be performed only when the receive level of the current serving cell is in the range "Edge HO DL RX_LEV Threshold" to "Edge HO DL RX_LEV Threshold" + "Load HO Bandwidth". In the handover algorithm of the second generation, load handovers can be performed only when the level difference between the neighboring cell and the serving cell is between "Inter-cell HO Hysteresis" - "Load HO Bandwidth" and "Inter-cell HO Hysteresis". GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 0~63 0~63 dB None 25 Cell This parameter is valid only when "LOADHOEN" in "SET GCELLHOBASIC" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LOADPWROFFEN Load Power-off Allowed State BSC6900 SET BTSDPMUBP(Optional) Whether to enable load power-off.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. GBFD-111202O&M of BTS Enumeration Type NO(NO), YES(YES) NO, YES None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LOADRESELALLOW Cell Load Reselection Allowed BSC6900 SET GCELLNC2PARA(Optional) Whether to allow the cell load reselection GBFD-116201Network-Controlled Cell Reselection (NC2) Enumeration Type FORBID(Forbid), PERMIT(Permit) FORBID, PERMIT None None PERMIT Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The function of cell load reselection is valid only when "NC2LoadResel" in "SET BSCPSSOFTPARA" is set to Support and "LOADRESELALLOW"is set to Permit.
LOADRESELMAXRXLEV Load Reselect Level Threshold BSC6900 SET GCELLNC2PARA(Optional) Threshold for allowing the MS to reselect a cell during load reelection. The load reselection can be performed only when the receiving level of the MS is below this threshold. GBFD-116201Network-Controlled Cell Reselection (NC2) Interval Type 0~63 0~63 dB None 40 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LOADRESELRXTHRSH Load Reselection Receive Threshold BSC6900 SET GCELLNC2PARA(Optional) When the cell load is below this threshold, the cell can accept the load reselection subscribers from other cells. When the TBF multiplexing ratio is less than the percentage, the cell can accept the load reselection subscribers from other cells. GBFD-116201Network-Controlled Cell Reselection (NC2) Interval Type 0~100 0~100 per cent None 60 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LOADRESELSTARTTHRSH Load Reselection Start Threshold BSC6900 SET GCELLNC2PARA(Optional) When the cell load exceeds this threshold, the load reselection is started. GBFD-116201Network-Controlled Cell Reselection (NC2) Interval Type 0~100 0~100 per cent None 85 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LOADSHAREALLOW Balance Traffic Allowed BSC6900 SET GCELLCHMGAD(Optional) If this parameter is set to YES, the channel assignment algorithm II randomly selects the start range for channel traversal; otherwise, the algorithm selects the channel next to the channel assigned last time as the start point of channel traversal. GBFD-111005Enhanced Channel Assignment Algorithm Enumeration Type NO(No), YES(Yes)NO, YES None None YES Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LOADTHSW TRM Load Threshold switch BSC6900 SET BTSABISPRIMAP(Optional) TRM load threshold switch None None Enumeration Type OFF(OFF), ON(ON) OFF, ON None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LocalBSCID Local BSC ID BSC6900 SET GBSCREDGRP(Mandatory) Local BSC identity. GBFD-113725BSC Node Redundancy Interval Type 0~65534 0~65534 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LOCALIP Local IP address BSC6900 ADD PPPLNK(Mandatory) Local IP address GBFD-118611GBFD-118622 Abis IP over E1/T1A IP over E1/T1 IP Address Type None 0.0.0.0~255.255.255.255 None None None BSC6900None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
LOCALIP Local IP address BSC6900 ADD MPGRP(Mandatory) Local IP address of the MP group GBFD-118611GBFD-118622 Abis IP over E1/T1A IP over E1/T1 IP Address Type None 0.0.0.0~255.255.255.255 None None None MP groupNone Read & Write N (No impact on the UE in idle mode) Not involved Not involved The local IP address and peer IP must be configured in the same network segment. The peer IP address cannot be the same with the local IP address of the BSC.
LOCALIP Local IP address BSC6900 ADD BTSPPPLNK(Mandatory)ADD BTSMPGRP(Mandatory) Local IP address GBFD-118611Abis IP over E1/T1 IP Address Type None 0.0.0.0.~255.255.255.255 None None None BTS The IP address must be in the same network segment as "Peer IP address". Read & Write Y BTS Less than 5 minutes None
LOCALNSVLI Local NSVL ID BSC6900 ADD NSVLLOCAL(Mandatory) Identifies a local NSVL. GBFD-118603Gb over IP Interval Type 0~1023 0~1023 None None None NSE None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
LOCALPORTNO Local Port No. BSC6900 ADD SGSNROUTEINFO(Mandatory) Identifies the local port of the router. GBFD-118603Gb over IP Interval Type 0~1 0~1 None None None BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LOCGRPNO Location Group No. BSC6900 ADD BTSLOCGRP(Mandatory)ADD BTSRXU2LOCGRP(Mandatory)SWP BTSLOCGRP(Mandatory) Number of the location group under the BTS. It is unique for each BTS. GBFD-510104Multi-site Cell Interval Type 0~35 0~35 None None None BTS None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
LOCGRPNO Location Group No. BSC6900 ADD BTSOBJALMSHLD(Mandatory) Number of a location group GBFD-510104Multi-site Cell Interval Type 0~35 0~35 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LOCIP1 First local IP address BSC6900 ADD SCTPLNK(Mandatory) First local IP address. The invalid value is 0. None None IP Address Type None 0.0.0.0~255.255.255.255 None None None SCTP linkNone Read & Write Y SCTP link The services are interrupted until the SCTP link is working normally. The both end address of the SCTP is the parameter for the interconnection. The value can be modified after the negotiation with the peer system.
LOCIP2 Second local IP address BSC6900 ADD SCTPLNK(Optional) Second local IP address. The invalid value is 0. None None IP Address Type None 0.0.0.0~255.255.255.255 None None None SCTP linkNone Read & Write Y SCTP link The services are interrupted until the SCTP link is working normally. The both end address of the SCTP is the parameter for the interconnection. The value can be modified after the negotiation with the peer system.
LOCKST Set Locked/Unlock BSC6900 SET OPLOCK(Mandatory) Whether to lock all the non-default local accounts GBFD-111203MRFD-210305 O&M of BSCSecurity Management Enumeration Type OFF(Unlock), ON(Lock) OFF, ON None ON OFF RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LOCPN Local SCTP port No. BSC6900 ADD SCTPLNK(Mandatory) Local SCTP port No. None None Interval Type 1024~65535 1024~65535 None None None SCTP linkWhen the value of "MODE" in "ADD SCTPLNK" is set to Client, this parameter can be modified. Read & Write Y SCTP link The services are interrupted until the SCTP link is working normally. The parameter can be modified when "MODE" in the command "ADD SCTPLNK" is set to Client.
LODCTRL Board Start Load Control. BSC6900 SET LODCTRL(Mandatory) board start load control. MRFD-210301Configuration Management Enumeration Type LFB(Load from OMU and write flash), CL(Consult Load) LFB, CL None None None BSC6900None Read & Write Not involved Not involved Not involved None
LODMODE Loading Mode BSC6900 LOD BTSSW(Optional)LOD BTSPATCH(Optional) Mode of software loading GBFD-111202O&M of BTS Enumeration Type NORMMODE(Normal Mode), RAPMODENOSERV(Rapid Mode<No service>), RAPMODERESSERV(Rapid Mode<Reserve BCCH trx>) NORMMODE, RAPMODENOSERV, RAPMODERESSERV None NORMMODE None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LOGCTHD Log control threshold BSC6900 SET FCCPUTHD(Optional) CPU usage threshold for log flow control. When the average CPU usage of sliding windows reaches or exceeds the threshold, log flow control is triggered. WRFD-040100Flow Control Interval Type 30~100 30~100 per cent None 95 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LOGCTHD Log control threshold BSC6900 SET FCMSGQTHD(Optional) Packet queue usage threshold for log flow control. When the average packet queue usage of sliding windows reaches or exceeds the threshold, log flow control is triggered. WRFD-040100Flow Control Interval Type 30~100 30~100 per cent None 80 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LOGPORTFLAG Logic Port Flag BSC6900 ADD SCTPLNK(Mandatory) Whether to specify the SCTP to bind the logic port. None None Enumeration Type NO(NO), YES(YES) NO, YES None None None SCTP linkThis parameter determines whether "LOGPORTSN" and "LOGPORTNO" in "ADD SCTPLNK" are valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LOGPORTNO Logic Port No. BSC6900 ADD SCTPLNK(Mandatory) Logic port No. bound by the SCTP. None None Interval Type 0~988 0~988 None None None SCTP linkWhen the value of "LOGPORTFLAG" in "ADD SCTPLNK" is set to ON, this parameter is valid. Read & Write Y SCTP link The services are interrupted until the SCTP link is working normally. It is valid when "LOGPORTFLAG[/PARA in the command "ADD SCTPLNK" is ON.
LOGPORTSN Logic Port Slot No. BSC6900 ADD SCTPLNK(Mandatory) Logic port slot No. bound by the SCTP. None None Interval Type 0~5,8~27 0~5, 8~27 None None None SCTP linkWhen the value of "LOGPORTFLAG" in "ADD SCTPLNK" is set to ON, this parameter is valid. Read & Write Y SCTP link The services are interrupted until the SCTP link is working normally. It is valid when "LOGPORTFLAG[/PARA in the command "ADD SCTPLNK" is ON.
LOGRTHD Log restore threshold BSC6900 SET FCCPUTHD(Optional) CPU usage threshold for recovery from log flow control. When the average CPU usage of sliding windows is lower than the threshold, log flow control is triggered. WRFD-040100Flow Control Interval Type 30~100 30~100 per cent None 85 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LOGRTHD Log restore threshold BSC6900 SET FCMSGQTHD(Optional) Packet queue usage threshold for recovery from log flow control. When the average packet queue usage of smooth windows is lower than the threshold, log flow control is triggered. WRFD-040100Flow Control Interval Type 30~100 30~100 per cent None 70 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LOGSW Log control switch BSC6900 SET FCSW(Optional) Whether to control the log flow WRFD-040100Flow Control Enumeration Type ON, OFF ON, OFF None None ON Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LOGTYPE Log File Type BSC6900 COL LOG(Mandatory) The log type to be collected. GBFD-111203O&M of BSC Bit Field Type PFM_RESULT, HOST_PFM_RESULT, ACTIVE_DEF_MEAS_FILE, STANDBY_DEF_MEAS_FILE, PFM_SWITCHS, HISTORY_ALARM, HISTORY_FAULT, ALM_SYSTEM_CFG, SECURITY_LOG, OPT_LOG, OMU_LOG, BSC_CFG_MML, CELL_BASIC_INFO, BSC_SERIES_NO, DB_BAK, MEM_DB_BAK, BTS_BASIC_INFO, BTS_CHECK_LOG, BTS_DEBUG_LOG, BTS_CHR_LOG, TRX_LOG, BTS_NET_TABLE, DEBUG_LOG, LAST_WORD, DSP_DEBUG_LOG, HOST_LOG, 2G_CHR_LOG, 3G_CHR_LOG, 2G_UNILATERAL_CONNECT, BSC_INFO, GCSR_LOG, GPSR_LOG, AIDG_LOG, BIOS_LOG PFM_RESULT, HOST_PFM_RESULT, ACTIVE_DEF_MEAS_FILE, STANDBY_DEF_MEAS_FILE, PFM_SWITCHS, HISTORY_ALARM, HISTORY_FAULT, ALM_SYSTEM_CFG, SECURITY_LOG, OPT_LOG, OMU_LOG, BSC_CFG_MML, CELL_BASIC_INFO, BSC_SERIES_NO, DB_BAK, MEM_DB_BAK, BTS_BASIC_INFO, BTS_CHECK_LOG, BTS_DEBUG_LOG, BTS_CHR_LOG, TRX_LOG, BTS_NET_TABLE, DEBUG_LOG, LAST_WORD, DSP_DEBUG_LOG, HOST_LOG, 2G_CHR_LOG, 3G_CHR_LOG, 2G_UNILATERAL_CONNECT, BSC_INFO, GCSR_LOG, GPSR_LOG, AIDG_LOG, BIOS_LOG None None None RNC None Read & Write Not involved Not involved Not involved None
LOGTYPE Log Type BSC6900 STR BTSLOG(Mandatory)ULD BTSLOG(Mandatory) Type of the log. "COMLOG" indicates a common log. "CMPLOG" indicates a compressed log. GBFD-111202O&M of BTS Enumeration Type COMLOG(Common Log), CMPLOG(Compress Log) COMLOG, CMPLOG None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LONGIDECI Longitude Decimal Part BSC6900 SET GCELLLCS(Mandatory) Decimal value when the longitude where a cell is located is indicated in the format of degree GBFD-115402BSS-Based LCS (Cell ID + TA) String Type None 1~5 characters degreeNone None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LONGIDEGREE Longitude Degree Part BSC6900 SET GCELLLCS(Mandatory) Value of the degree part when the latitude is indicated in the format of degree_minute_second GBFD-115402BSS-Based LCS (Cell ID + TA) Interval Type 0~180 0~180 degreeNone None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LONGIINT Longitude Int Part BSC6900 SET GCELLLCS(Mandatory) Integer value when the longitude where a cell is located is indicated in the format of degree GBFD-115402BSS-Based LCS (Cell ID + TA) Interval Type 0~180 0~180 degreeNone None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LONGIMINUTE Longitude Minute Part BSC6900 SET GCELLLCS(Mandatory) Value of the minute part when the longitude is indicated in the format of degree_minute_second GBFD-115402BSS-Based LCS (Cell ID + TA) Interval Type 0~59 0~59 minuteNone None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LONGISECONDDECI Longitude Second Decimal Part BSC6900 SET GCELLLCS(Mandatory) Decimal value of the second part when the longitude is indicated in the format of degree_minute_second GBFD-115402BSS-Based LCS (Cell ID + TA) Interval Type 0~9 0~9 secondNone None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LONGISECONDINT Longitude Second Int Part BSC6900 SET GCELLLCS(Mandatory) Integer value of the second part when the longitude is indicated in the format of degree_minute_second GBFD-115402BSS-Based LCS (Cell ID + TA) Interval Type 0~59 0~59 secondNone None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LOOPMODE Loopback Type BSC6900 STR FRPORTLOOP(Mandatory) Loop type.1. Local loop:Make loop test on the local board at system side, while the system platform will send test frames.2. Remote loop:The remote-loop will be made by the device on the other side of the local board. In this case, the local board don't need to make loop opertation except sending test frames. GBFD-510002Gb Over FR Enumeration Type BYLOCAL(By Local Loop), BYREMOTE(By Remote Loop) BYLOCAL, BYREMOTE None None None BC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LOOPTYPE Loop type BSC6900 LOP LAPDLNK(Mandatory) Loopback type of LAPD link GBFD-111203O&M of BSC Enumeration Type LOOPTYPE_TDM(Line Loop), LOOP_TYPE_LVDS(LVDS Loop), LOOPTYPE_MCC(MCC Loop) LOOPTYPE_TDM, LOOP_TYPE_LVDS, LOOPTYPE_MCC None None None None None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
LOOSESDCCHLOADTHRED IBCA Loose Trx SDCCH Load Threshold BSC6900 SET GCELLCHMGAD(Optional) When the load of an SDCCH on the TRX that is in loose frequency reuse and is in the compatible band of the BCCH is lower than this threshold, the SDCCH is preferably allocated. GBFD-117002IBCA (Interference Based Channel Allocation) Interval Type 0~100 0~100 per cent None 80 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LOPDIR Loop Direction BSC6900 STR CALLRESLOP(Mandatory) Direction of an external voice loop GBFD-111203O&M of BSC Enumeration Type MSC(MSC Direction), MS(MS Direction) MSC, MS None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LOPLOC Loop Position BSC6900 STR CALLRESLOP(Mandatory) Loopback point. There are 14 loopback points. Whether a loopback point is available depends on the subrack configuration mode in the BSS and the transmission mode of each interface. The details are as follows:NSS Interface Unit: indicates the A interface board in various configuration modes, such as BM/TC separated, BM/TC combined, and A over IP.NSS TC(Near Abis Interface): indicates the TX/RX point on the DSP in the TC subrack on the Abis interface side. The loopback point is available only in BM/TC separated configuration mode.NSS TC(Near A Interface): indicates the TX/RX point on the DSP in the TC subrack on the A interface side. The loopback point is available only in BM/TC separated configuration mode.NSS TNU(Near Abis Interface): indicates the data switching point on the TNUa board in the TC subrack on the Abis interface. The loopback point is available only when the Ater interface uses the TDM transmission in BM/TC separated configuration mode.NSS TNU(Near A Interface): indicates the data switchin GBFD-111203O&M of BSC Enumeration Type NSSAINTF(NSS Interface Unit), NSSTCTOABIS(NSS TC(Near Abis Interface)), NSSTCTOA(NSS TC(Near A Interface)), NSSTNUTOABIS(NSS TNU(Near Abis Interface)), NSSTNUTOA(NSS TNU(Near A Interface)), NSSATERINTF(NSS Ater Interface Unit), BSSATERINTF(BSS Ater Interface Unit), BSSTCTOABIS(BSS TC(Near Abis Interface)), BSSTCTOA(BSS TC(Near A Interface)), BSSTNUTOABIS(BSS TNU(Near Abis Interface)), BSSTNUTOA(BSS TNU(Near A Interface)), BSSABISINTF(BSS Interface Unit), BTSTMU(TMU/PTU), BTSTRUDSP(TRU DSP) NSSAINTF, NSSTCTOABIS, NSSTCTOA, NSSTNUTOABIS, NSSTNUTOA, NSSATERINTF, BSSATERINTF, BSSTCTOABIS, BSSTCTOA, BSSTNUTOABIS, BSSTNUTOA, BSSABISINTF, BTSTMU, BTSTRUDSP None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LOPT Loop type BSC6900 SET E1T1LOP(Mandatory) Loopback typeNone None Enumeration Type NO_LOOP(No loop), REMOTE_LOOP(Remote loop), LINE_REM_LOOP(Line remote loop), LOCAL_LOOP(Local loop), PAYLOAD_LOOP(payload loop), SIN_CHN_LOC(single channel local loop), SIN_CHN_REM(single channel remote loop) NO_LOOP, REMOTE_LOOP, LINE_REMOTE_LOOP, LOCAL_LOOP, PAYLOAD_LOOP, SIN_CHN_LOC, CIN_CHN_REM None None None E1/T1 port None Read & Write Y E1/T1 port The loopback keeps interrupting the services until it is cancelled. If this parameter is set to REMOTE_LOOP and LOCAL_LOOP, the service on this link is affected until the loopback is cancelled.When the upper layer bearer is IMAGRP, IMAGRP is reset after the loopback is canceled. Otherwise, the state of the IMAGRP is abnormal and upper layer service cannot be established.
LOPT Loop type. BSC6900 SET OPTLOP(Mandatory) Loopback typeNone None Enumeration Type NO_LOOP(NO_LOOP), LOCAL_LOOP(LOCAL_LOOP), REMOTE_LOOP(REMOTE_LOOP) NO_LOOP, REMOTE_LOOP, LOCAL_LOOP None None None Loopback optical port None Read & Write Y BSC6900 The loopback keeps interrupting the services until it is cancelled. When the loopback type is changed to REMOTE_LOOP or LOCAL_LOOP, the service is affected. The service becomes normal when the loopback test is canceled. When the loopback type is set to LOCAL_LOOP, you cannot directly change it to REMOTE_LOOP. You must change it to NO_LOOP first and then to REMOTE_LOOP. You can change the loopback type from REMOTE_LOOP to LOCAL_LOOP in the similar way.
LOPTIME Loop Time BSC6900 STR CALLRESLOP(Optional) Time of an external voice loop GBFD-111203O&M of BSC Interval Type 60~600 60~600 s 180 None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LOSTSUSTM Suspend times after bandwidth adjusted BSC6900 ADD IPLOGICPORT(Optional) Number of suspension periods after the bandwidth adjustment is performed based on the packet drop ratio. This parameter specifies the delay statistics periods in which the bandwidth is not adjusted when the bandwidth adjustment function of the logical port is triggered due to the change of the packet drop ratio. This parameter can be used to control the rate of the bandwidth adjustment at the logical port. None None Interval Type 1~100 1~100 None 1 1 IP logical port None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LOWLEVSUBRESPREEMPTFLG Low-level Sublink Resource Preempt Switch BSC6900 SET GCELLSOFT(Optional) Whether to permit the preemption of lower-level sublink resources. If the value of this parameter is YES, a CS domain service can preempt the sublink resources of the PS domain services on the lower-level BTS of the cascaded BTSs when the CS domain service fails to preempt the sublink of the corresponding level. GBFD-117301Flex Abis Enumeration Type NO(No), YES(Yes)NO, YES None None None Cell This parameter is valid when "FLEXABISMODE" in the "MOD BTS" command is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LOWLEVSUBRESPREEMPTFLG Low Lev Sub Res Preempt Flag BSC6900 SET BTSFLEXABISPARA(Optional) The CS services are preferred. This parameter indicates that the CS services are permitted to preempt the dynamic Abis resources on the sublink of the current level site. GBFD-117301Flex Abis Enumeration Type NO(NO), YES(YES) NO, YES None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LOWNOISESWH Diversity LNA Bypass Permitted BSC6900 SET GCELLOTHBASIC(Optional) Whether to permit the low noise amplifier (LNA) bypass GBFD-111202O&M of BTS Enumeration Type OFF(Off), ON(On) OFF, ON None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved For the BTS3002C, if each cell is configured with two TRXs (O2 or S2) and the value of this parameter is YES, the radio frequency (RF) connection supports the configuration of the main diversity antennas. Only the BTS3002C has this parameter.
LOWRXLEVOLFORBIDSWITCH L-Rxlev Overlayer ForbidAllocate Switch BSC6900 SET GCELLCHMGAD(Optional) Whether to assign overlay channels in an IUO cell based on the receive level conditions GBFD-113201Concentric Cell Enumeration Type OFF(Off), ON(On) OFF, ON None None ON Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LOWTEMPLOADPWROFF Lowtemp startloadpower-off allowed state BSC6900 SET BTSAPMUBP(Optional) Whether to power off the TRX in the case of overlow temperature of the BTS cabinet. If this parameter is set to "Yes", the BTS powers off the TRX and reports a "Load Power Off Alarm" to protect the TRX in the case of overlow temperature of the BTS cabinet. When the cabinet temperature returns to 0 celsius degree, the BTS powers on the TRX, and the alarm disappears. GBFD-111202O&M of BTS Enumeration Type NO(NO), YES(YES) NO, YES None None For APM4815 boards, the value of this parameter is set to "NO". BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LOWTEMPLOADPWROFF LowTemp StartLoadPower-off Allowed State BSC6900 SET BTSDPMUBP(Optional) Whether to power off the TRX of a BTS when the temperature of the BTS cabinet is too low.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. GBFD-111202O&M of BTS Enumeration Type NO(NO), YES(YES) NO, YES None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LPBKMODE Loop Back Mode BSC6900 STR TRANSPERFTST(Mandatory) Loopback modeGBFD-111203O&M of BSC Enumeration Type E1(E1 Loopback), TIMESLOT(Timeslot Loopback) E1, TIMESLOT None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LPN IP Logic Port No. BSC6900 ADD IPPATH(Mandatory) IP logic port No. carried by the IP path None None Interval Type 0~988 0~988 None None None IP path When the value of "CARRYFLAG" in "ADD IPPATH" is set to IP LGCPORT, this parameter is valid. Read & Write Y IP path Less than 5 minutes None
LPN Logic port No. BSC6900 ADD IPLOGICPORT(Optional)SET BTSIP(Mandatory) Logical port number None None Interval Type 0~988,1024~1535FG2a/GOUa/UOIa(IP)board:0~119;FG2c/GOUcboard:0~499, 512~767;POUc(IP)board:0~988, 1024~1535 None None None IP logical port None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
LPNSN IP Logic Port Slot No. BSC6900 ADD IPPATH(Mandatory) IP logic port slot No. carried by the IP path None None Interval Type 0~5,8~27 0~5, 8~27 None None None IP path When the value of "CARRYFLAG" in "ADD IPPATH" is set to IP LGCPORT, this parameter is valid. Read & Write Y IP path Less than 5 minutes None
LPNTYPE Type of the logic port BSC6900 ADD IPLOGICPORT(Mandatory) Type of logical port None None Enumeration Type Hub(Hub), Leaf(Leaf) Hub, Leaf None None None ATM logical port None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
LQCMODE Link Quality Control Mode BSC6900 SET GCELLEGPRSPARA(Optional) It is applicable to the radio transmission environment to improve the link quality. Link adaptation (LA) indicates adjusting the coding mode of the channel dynamically according to the transmission quality of the link. The link transmission quality is measured by the 8PSK MEAN BEP and 8PSK CV BEP in the Packet EGPRS Downlink Ack/Nack message sent by the MS. The network side determines the coding mode for data transmission according to the radio measurement report sent by the MS. The cell with the good transmission quality on the air interface is set to the LA mode. Increment redundancy (IR) mode requires the network side retransmit the data block with different punching codes and the MS store the historical error information. The data block is retransmitted through cooperated error correction function. With the IR mode, the transmission quality on the air interface of the cell can be improved. However, the MS must support this IR mode. The cell with the dissatisfied transmission quality on the air interface i GBFD-114201EGPRS Enumeration Type IR(IR), LA(LA) IR, LA None None IR Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LSDF Load Shutdown Flag BSC6900 SET BTSAPMUBP(Optional) Whether to enable power shutdown upon low voltage of the battery.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. GBFD-111202O&M of BTS Enumeration Type DISABLE(DISABLE), ENABLE(ENABLE) DISABLE, ENABLE None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LSDV Load Shutdown Voltage BSC6900 SET BTSAPMUBP(Optional) Load power-off voltage threshold. If "Load Shutdown Flag" is set to "Enable" and the load voltage is lower than the value of this parameter, the load is automatically powered off.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. GBFD-111202O&M of BTS Interval Type 350~556 35~55.6 (step: 0.1) V None If "Power System Type" is "SC48200", the recommended value is "475". If "Power System Type" is "EPS4815", the value is "4294967295" (HEX: FFFFFFFF) and cannot be modified. For other Power System Type of APMU boards, the recommended value is "440". BTS The value of this parameter must be smaller than "DC Undervoltage Alarm Threshold". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LSRTRD LDR Third BSC6900 SET LDR(Optional)Third action taken for load control GBFD-118601Abis over IP Enumeration Type CLOSE(Close), PSDOWN(PS Downspeeding), AMRC(AMRC), CSPH(CS Preference TCHH), CSFHHO(CS TCHF-TCHH HO) CLOSE, PSDOWN, AMRC, CSPH, CSFHHO None None None BSC6900If this parameter is not set to CLOSE, it value must not be the same as "LDRSND", "LDRFST", or "LDRFOUH". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LSTCMD Whether Include List Command BSC6900 EXP LOG(Optional) Whether to include the list command GBFD-111203MRFD-210305 O&M of BSCSecurity Management Enumeration Type EXCLUDE(exclude list command), INCLUDE(include list command) EXCLUDE, INCLUDE None None INCLUDE RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LstFormat Result list format BSC6900 CMP TBLDATA(Optional) Query results can be displayed vertically or horizontally. MRFD-210301Configuration Management Enumeration Type HORIZONTAL(HORIZONTAL), VERTICAL(VERTICAL) HORIZONTAL, VERTICAL None HORIZONTAL None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LT Log Type BSC6900 SET LOGLIMIT(Mandatory) Type of the logGBFD-111203MRFD-210305 O&M of BSCSecurity Management Enumeration Type OPTLOG(Operation Log), SECLOG(Security Log) OPTLOG, SECLOG None OPTLOG None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LT Log Type BSC6900 EXP LOG(Mandatory) Type of the logGBFD-111203MRFD-210305 O&M of BSCSecurity Management Enumeration Type OPTLOG(MML OPERATING LOG), SECLOG(SECURITY LOG) OPTLOG, SECLOG None None OPTLOG RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LTCP Low Temperature Critical Point BSC6900 SET BTSDHEUBP(Optional) Temperature control threshold for low temperature. When the ambient temperature is less than "Low Temperature Critical Point", the temperature control system needs to control the temperature difference between the air inlet and air outlet, and that between the air inlet and ambient temperature.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. GBFD-111202O&M of BTS Interval Type -99~70 -99~70 degree Celsius None 0 BTS The value of this parameter must be smaller than "High Temperature Critical Point". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LTEMTHD Lower Temperature Threshold BSC6900 SET BTSEXD(Optional) Lower temperature threshold for the environment alarm box to report an alarm indicating that the ambient temperature is too low. If the ambient temperature of the BTS is lower than this threshold, the environment alarm box reports the alarm.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. GBFD-111202O&M of BTS Interval Type -99~99 -99~99 degree Celsius None 0 BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter must be less than "UTEMTHD".
LTFERLOWTH Long-term FER Lower Threshold BSC6900 SET GCELLCCAMR(Optional) Lower voice quality threshold associated with the automatic adjustment of the AMR handover threshold. The value of this parameter must be smaller than or equal to the value of Long-term FER Target. GBFD-115506AMR Coding Rate Threshold Adaptive Adjustment Interval Type 2~255 2~255 None 2 2 Cell The setting of this parameter must meet the following conditions: "LTFERLOWTH" < "LTFERTGT"; "LTFERLOWTH" < "LTFERUPTH". Read & Write N (No impact on the UE in idle mode) Not involved Not involved Generally, the value of this parameter does not need adjustment. It is the lower limit for adjusting the value of LongTermFERTarget.
LTFERTGT Uplink Long-term FER Target BSC6900 SET GCELLCCAMR(Optional) Target voice quality value associated with the automatic adjustment of the uplink threshold of AMR handover GBFD-115506AMR Coding Rate Threshold Adaptive Adjustment Interval Type 2~255 2~255 None 8 8 Cell The setting of this parameter must meet the following conditions:"LTFERLOWTH" < "LTFERTGT";"LTFERTGT" < "LTFERUPTH". Read & Write N (No impact on the UE in idle mode) Not involved Not involved The value of this parameter decides whether the threshold is adjusted upwards or downwards. When the voice is in poor performance (excluding the cause of poor channel quality: If the low rate mode is more used in the adaptation, you can increase the value of this parameter; if the high rate mode is more used in the adaptation (excluding the cause of good channel quality), you can decrease the value of this parameter. If the DTX function is enabled, the value of this parameter must be a little greater than the value when the DTX function is disabled.
LTFERUPTH Long-term FER Upper Threshold BSC6900 SET GCELLCCAMR(Optional) Upper voice quality threshold associated with the automatic adjustment of the AMR handover threshold GBFD-115506AMR Coding Rate Threshold Adaptive Adjustment Interval Type 2~255 2~255 None 60 60 Cell The setting of this parameter must meet the following conditions: "LTFERUPTH" > "LTFERTGT"; "LTFERUPTH" > "LTFERLOWTH". Read & Write N (No impact on the UE in idle mode) Not involved Not involved Generally, the value of this parameter does not need adjustment. It is the upper limit for adjusting the value of LongTermFERTarget.
LTTHADJFA Threshold Adjust Factor BSC6900 SET GCELLCCAMR(Optional) Factor of threshold adjustment. It indicates the linear relation between the threshold adjustment value and the logarithmic FER. GBFD-115506AMR Coding Rate Threshold Adaptive Adjustment Interval Type 2~255 2~255 None 2 2 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved Generally, the value of this parameter is fixed to 2, with no need of adjustment. The value of this parameter decides only the adjustment value or the adjusting frequency of the threshold. That is, the greater the value of this parameter is, the more frequently the threshold is adjusted. The setting of this parameter, however, does not affect the up or down adjustment of the threshold.
Lvl1Vswr Lvl1 Vswr BSC6900 SET BTSRXUBP(Optional) Level-1 standing wave threshold GBFD-111202O&M of BTS Enumeration Type 14(1.4), 15(1.5), 16(1.6), 18(1.8), 20(2.0), 22(2.2), 24(2.4), 26(2.6), 28(2.8), 30(3.0), 33(3.3), 36(3.6), 88(8.8) 14, 15, 16, 18, 20, 22, 24, 26, 28, 30, 33, 36, 88 None 20 None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
Lvl2Vswr Lvl2 Vswr BSC6900 SET BTSRXUBP(Optional) Level-2 standing wave threshold GBFD-111202O&M of BTS Enumeration Type 18(1.8), 20(2.0), 22(2.2), 24(2.4), 26(2.6), 28(2.8), 30(3.0), 32(3.2), 35(3.5), 38(3.8), 41(4.1), 45(4.5), 88(8.8) 18, 20, 22, 24, 26, 28, 30, 32, 35, 38, 41, 45, 88 None 30 None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
LVSDF Low Voltage Shutdown Flag BSC6900 SET BTSAPMUBP(Optional) Whether "Shutdown Voltage" is valid.In multi-mode base station scenario, the value of this parameter in different modes must be the same for the same multi-mode base station. GBFD-111202O&M of BTS Enumeration Type DISABLE(DISABLE), ENABLE(ENABLE) DISABLE, ENABLE None None For APM4815, the recommended value is "NO". For other types of APMU boards, the recommended value is "YES". BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
M3UASRVPN M3UA service listening port No. BSC6900 SET SCTPSRVPORT(Optional) Number of the M3UA service listening port None None Interval Type 1024~65535 1024~65535 None None 2905 SCTP linkNone Read & Write Y SCTP link The services are interrupted until the SCTP link is working normally. The parameter modification should be negotiated with the peer end, and the BSC should be reset after the modification. It is recommended that this parameter should not be modified when the system is running.
MAC MAC Address BSC6900 ADD XPUVLAN(Mandatory) MAC address of the VLAN MRFD-210301Configuration Management Interval Type 0~8191 0~8191 None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MACODINGMOD ARFCN Coding Scheme BSC6900 SET GCELLSOFT(Optional) Coding mode in which an ARFCN is sent to an MS during an assignment or handover. If the parameter is set to CA_MA, an ARFCN is indicated through the CA and MA information contained in an assignment or handover command. If the parameter is set to Frequency_List, an ARFCN is indicated through the Frequency List information contained in an assignment or handover command. If this parameter is set to OPTIMIZED_CA_MA, the assignment command carries only the MA but not the CA when a cell works on only one frequency band, and the assignment command carries both the MA and CA if the cell works on more than one frequency band. GBFD-113701Frequency Hopping (RF hopping, baseband hopping) Enumeration Type CA_MA(CA+MA), Frequency_List(Frequency List), OPTIMIZED_CA_MA(Optimized CA+MA) CA_MA, Frequency_List, OPTIMIZED_CA_MA None None CA_MA Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved If there are fewer frequencies in a frequency hopping group, the mode of Frequency List can decrease the length of an assignment or handover command to facilitate the access of an MS.
MAIDX MA Index BSC6900 ADD ETHMA(Mandatory)ADD ETHMEP(Mandatory)PING MAC(Mandatory)TRC MAC(Mandatory) Identifies a maintenance group.Maintenance group: maintenance alliance (MA), which is a component of the maintenance domain (MD). Maintenance domain is an Ethernet or a component of an Ethernet in which the connectivity failure management is performed. The maintenance domain is uniformly managed by one ISP. One MD can be divided into one or more maintenance group. GBFD-118630Ethernet OAM Interval Type 0~499 0~499 None None None Board None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
MAINBCCHPWDTACTCHEN Power Derating Active Channel Enabled BSC6900 SET GCELLOTHEXT(Optional) Whether to reduce the transmit power of the channels with the power derating function enabled in the non-BCCH timeslots of the BCCH TRXs GBFD-111609Enhanced BCCH Power Consumption Optimization Enumeration Type NO(No), YES(Yes)NO, YES None None NO Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MAINBCCHPWRDTEN Power Derating Enabled BSC6900 SET GCELLOTHEXT(Optional) Whether to enable the power derating function over the non-BCCH timeslots of the BCCH TRXs GBFD-111609Enhanced BCCH Power Consumption Optimization Enumeration Type NO(No), YES(Yes)NO, YES None None NO Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MAINBCCHPWRDTETIME Power Derating Start Time BSC6900 SET GCELLOTHEXT(Optional) End time of the period in which the power in the non-BCCH timeslots of the BCCH TRXs is derated GBFD-111609Enhanced BCCH Power Consumption Optimization Compound Type hour, min 00:00~23:59 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MAINBCCHPWRDTRANGE Power Derating Range BSC6900 SET GCELLOTHEXT(Optional) Range of power derating in the non-BCCH timeslots of the BCCH TRXs GBFD-111609Enhanced BCCH Power Consumption Optimization Interval Type 0~15 0~15 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MAINBCCHPWRDTSTIME Power Derating End Time BSC6900 SET GCELLOTHEXT(Optional) Start time of the period in which the power in the non-BCCH timeslots of the BCCH TRXs is derated GBFD-111609Enhanced BCCH Power Consumption Optimization Compound Type hour, min 00:00~23:59 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MAINDEVTAB BTS Interface Board Bar Code 1 BSC6900 ADD BTSESN(Mandatory) Bard code 1 of the interface board of the BTS None None String Type None 1~64 characters None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MAINDEVTAB PTU Main Dev Tab BSC6900 ADD BTSAUTOPLAN(Mandatory) Bar code 1 of the BTS interface board GBFD-118601Abis over IP String Type None 1~64 characters None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MAINLOCGRPNO Main Location Group No. BSC6900 ADD BTSBINDLOCGRP(Mandatory) Number of main location group. Each cell contains only one main location group. GBFD-510104Multi-site Cell Interval Type 0~35 0~35 None None None BTS None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
MAINPORTNO Main Port No BSC6900 ADD BTS(Optional) Number of the port to which the active OML of the BTS is connected MRFD-210206Tree Topology Interval Type 0~1 0~1 None 0 0 BTS None Read & Write Y BTS Less than 5 minutes None
MainVer Main Version No.of TMU BSC6900 SET BTSAUTODLDACTINFO(Mandatory) Main version No. of the TMU board software. It is configured according to the actual situation. GBFD-111202O&M of BTS Interval Type 0~9999 0~9999 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MAIO1 MAIO 1 BSC6900 SET GCELLMAIOPLAN(Optional) Mobile allocation index offset 1. Start frequency number, which is the number of the frequency where frequency hopping starts GBFD-117002IBCA (Interference Based Channel Allocation) Interval Type 0~11 0~11 None None None Cell This parameter is valid only when "IBCAALLOWED" in "SET GCELLCHMGAD" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MAIO10 MAIO 10 BSC6900 SET GCELLMAIOPLAN(Optional) Mobile allocation index offset 10. Start frequency number, which is the number of the frequency where frequency hopping starts GBFD-117002IBCA (Interference Based Channel Allocation) Interval Type 0~11 0~11 None None None Cell This parameter is valid only when "IBCAALLOWED" in "SET GCELLCHMGAD" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MAIO11 MAIO 11 BSC6900 SET GCELLMAIOPLAN(Optional) Mobile allocation index offset 11. Start frequency number, which is the number of the frequency where frequency hopping starts GBFD-117002IBCA (Interference Based Channel Allocation) Interval Type 0~11 0~11 None None None Cell This parameter is valid only when "IBCAALLOWED" in "SET GCELLCHMGAD" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MAIO12 MAIO 12 BSC6900 SET GCELLMAIOPLAN(Optional) Mobile allocation index offset 12. Start frequency number, which is the number of the frequency where frequency hopping starts GBFD-117002IBCA (Interference Based Channel Allocation) Interval Type 0~11 0~11 None None None Cell This parameter is valid only when "IBCAALLOWED" in "SET GCELLCHMGAD" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MAIO2 MAIO 2 BSC6900 SET GCELLMAIOPLAN(Optional) Mobile allocation index offset 2. Start frequency number, which is the number of the frequency where frequency hopping starts GBFD-117002IBCA (Interference Based Channel Allocation) Interval Type 0~11 0~11 None None None Cell This parameter is valid only when "IBCAALLOWED" in "SET GCELLCHMGAD" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MAIO3 MAIO 3 BSC6900 SET GCELLMAIOPLAN(Optional) Mobile allocation index offset 3. Start frequency number, which is the number of the frequency where frequency hopping starts GBFD-117002IBCA (Interference Based Channel Allocation) Interval Type 0~11 0~11 None None None Cell This parameter is valid only when "IBCAALLOWED" in "SET GCELLCHMGAD" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MAIO4 MAIO 4 BSC6900 SET GCELLMAIOPLAN(Optional) Mobile allocation index offset 4. Start frequency number, which is the number of the frequency where frequency hopping starts GBFD-117002IBCA (Interference Based Channel Allocation) Interval Type 0~11 0~11 None None None Cell This parameter is valid only when "IBCAALLOWED" in "SET GCELLCHMGAD" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MAIO5 MAIO 5 BSC6900 SET GCELLMAIOPLAN(Optional) Mobile allocation index offset 5. Start frequency number, which is the number of the frequency where frequency hopping starts GBFD-117002IBCA (Interference Based Channel Allocation) Interval Type 0~11 0~11 None None None Cell This parameter is valid only when "IBCAALLOWED" in "SET GCELLCHMGAD" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MAIO6 MAIO 6 BSC6900 SET GCELLMAIOPLAN(Optional) Mobile allocation index offset 6. Start frequency number, which is the number of the frequency where frequency hopping starts GBFD-117002IBCA (Interference Based Channel Allocation) Interval Type 0~11 0~11 None None None Cell This parameter is valid only when "IBCAALLOWED" in "SET GCELLCHMGAD" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MAIO7 MAIO 7 BSC6900 SET GCELLMAIOPLAN(Optional) Mobile allocation index offset 7. Start frequency number, which is the number of the frequency where frequency hopping starts GBFD-117002IBCA (Interference Based Channel Allocation) Interval Type 0~11 0~11 None None None Cell This parameter is valid only when "IBCAALLOWED" in "SET GCELLCHMGAD" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MAIO8 MAIO 8 BSC6900 SET GCELLMAIOPLAN(Optional) Mobile allocation index offset 8. Start frequency number, which is the number of the frequency where frequency hopping starts GBFD-117002IBCA (Interference Based Channel Allocation) Interval Type 0~11 0~11 None None None Cell This parameter is valid only when "IBCAALLOWED" in "SET GCELLCHMGAD" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MAIO9 MAIO 9 BSC6900 SET GCELLMAIOPLAN(Optional) Mobile allocation index offset 9. Start frequency number, which is the number of the frequency where frequency hopping starts GBFD-117002IBCA (Interference Based Channel Allocation) Interval Type 0~11 0~11 None None None Cell This parameter is valid only when "IBCAALLOWED" in "SET GCELLCHMGAD" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MAJORALMUP0 Feed Tri. 0 TMA Over Critical Alm Thred. BSC6900 SET BTSDATUBP(Optional) Critical alarm threshold against excessive TMA feed current of feed tributary 0. When the actual current is greater than the specified value, a TMA feed current critical alarm is generated. MRFD-210304Faulty Management Interval Type 0~2000 0~2000 mA None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MAJORALMUP1 Feed Tri. 1 TMA Over Critical Alm Thred. BSC6900 SET BTSDATUBP(Optional) Critical alarm threshold against excessive TMA feed current of feed tributary 1. When the actual current is greater than the specified value, the TMA feed current critical alarm is generated. MRFD-210304Faulty Management Interval Type 0~2000 0~2000 mA None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MAJORALMUP2 Feed Tri. 2 TMA Over Critical Alm Thred. BSC6900 SET BTSDATUBP(Optional) Critical alarm threshold against excessive TMA feed current of feed tributary 2. When the actual current is greater than the specified value, the TMA feed current critical alarm is generated. MRFD-210304Faulty Management Interval Type 0~2000 0~2000 mA None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MAJORALMUP3 Feed Tri. 3 TMA Over Critical Alm Thred. BSC6900 SET BTSDATUBP(Optional) Critical alarm threshold against excessive TMA feed current of feed tributary 3. When the actual current is greater than the specified value, the TMA feed current critical alarm is generated. MRFD-210304Faulty Management Interval Type 0~2000 0~2000 mA None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MAJORALMUP4 Feed Tri. 4 TMA Over Critical Alm Thred. BSC6900 SET BTSDATUBP(Optional) Critical alarm threshold against excessive TMA feed current of feed tributary 4. When the actual current is greater than the specified value, the TMA feed current critical alarm is generated. MRFD-210304Faulty Management Interval Type 0~2000 0~2000 mA None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MAJORALMUP5 Feed Tri. 5 TMA Over Critical Alm Thred. BSC6900 SET BTSDATUBP(Optional) Critical alarm threshold against excessive TMA feed current of feed tributary 5. When the actual current is greater than the specified value, the TMA feed current critical alarm is generated. MRFD-210304Faulty Management Interval Type 0~2000 0~2000 mA None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MANAME MA Name BSC6900 ADD ETHMA(Mandatory)PING BTSCFM(Mandatory)TRC BTSCFM(Mandatory) Name of the MAGBFD-118630Ethernet OAM String Type None 1~20 characters None None None Ethernet port None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
MANAME MA Name BSC6900 ADD BTSETHMA(Mandatory)ADD BTSETHLCMEP(Mandatory)ADD BTSETHRMMEP(Mandatory) Name of the maintenance association. GBFD-118630MRFD-210301 Ethernet OAMConfiguration Management String Type None 1~20 characters None None None Ethernet port None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
MASK Subnet mask BSC6900 ADD DEVIP(Mandatory)ADD ETHIP(Mandatory)ADD EMSIP(Mandatory) Subnet mask of the board None None IP Address Type None 0.0.0.0~255.255.255.255 None None None BSC6900None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
MASK Subnet mask BSC6900 ADD PPPLNK(Mandatory) Subnet mask of the PPP link GBFD-118611GBFD-118622 Abis IP over E1/T1A IP over E1/T1 IP Address Type None 0.0.0.0~255.255.255.255 None None None PPP link None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
MASK Subnet mask BSC6900 ADD MPGRP(Mandatory) Subnet mask of the MP group GBFD-118611GBFD-118622 Abis IP over E1/T1A IP over E1/T1 IP Address Type None 0.0.0.0~255.255.255.255 None None None MP groupNone Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MASK Packet source mask BSC6900 ADD ICMPGUARD(Mandatory) Mask of the source IP network segment of the packet against the ICMP attack None None IP Address Type None 0.0.0.0~255.255.255.255 None None None Ethernet port None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
MASK Subnet mask BSC6900 ADD IPRTBIND(Mandatory)ADD ETHTRKIP(Mandatory) Subnet mask None None IP Address Type None 0.0.0.0~255.255.255.255 None None None Ethernet port None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
MASK Mask BSC6900 ADD GCBSADDR(Mandatory) Subnet mask of the CBC GBFD-113601Short Message Service Cell Broadcast (TS23) IP Address Type None 0.0.0.0~255.255.255.255 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MASK IP Mask BSC6900 SET BTSETHPORT(Optional) IP subnet mask of a BTS port GBFD-118601Abis over IP IP Address Type None 0.0.0.0~255.255.255.255 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MASK Subnet mask BSC6900 ADD BTSPPPLNK(Mandatory)ADD BTSMPGRP(Mandatory) Subnet mask of a PPP link GBFD-118611Abis IP over E1/T1 IP Address Type None 0.0.0.0.~255.255.255.255 None None None BTS None Read & Write Y PPP link Less than 5 minutes None
MASTERIPADDR Master Clock Server IP Address BSC6900 ADD BTSAUTOPLAN(Mandatory) IP address of the main clock server. It must be a legal A/B/C type address but not a broadcast address or network address. GBFD-118606Clock over IP IP Address Type None 0.0.0.0~255.255.255.255 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MASTERIPADDR Master Clock Server IP Address BSC6900 SET BTSIPCLKPARA(Mandatory) It must be the valid address of the A, B, or C type and cannot be the broadcast address or network address. GBFD-118606Clock over IP IP Address Type None 0.0.0.0~255.255.255.255 None None None BTS The setting of this parameter cannot be duplicate with "Slave Clock Server IP Address". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MAXADJPCVAL MAX Up Adj. PC Value by Qual. BSC6900 SET GCELLPWR2(Optional) Step of upward power adjustment according to the quality of the received signals GBFD-110703Enhanced Power Control Algorithm Interval Type 0~32 0~32 dB None 8 Cell This parameter is valid when "PWRCTRLSW" in the "SET GCELLPWRBASIC" command is set to PWR2. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MAXASSOCRETR Association max retrans BSC6900 ADD SCTPLNK(Optional) If the number of the association retransmissions exceeds this value, the parameter is deleted automatically. The value must be greater than Path max retrans. None None Interval Type 0~254 0~254 None None 10(application type is NBAP), 4(application type is M3UA) SCTP linkThe value to be set should be larger than the value of "MAXPATHRETR" in "ADD SCTPLNK". Read & Write N (No impact on the UE in idle mode) Not involved Not involved The value should be greater than "MAXPATHRETR" in the command "ADD SCTPLNK".
MAXBW Max bandwidth [64kbps] BSC6900 ADD IPLOGICPORT(Mandatory) Maximum bandwidth for dynamic adjustment at the logical port None None Interval Type 1~1000 64~64000, step:64 kbit/s None None IP logical port None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
5/5/2014
Confidential Information of Huawei.
No Spreading without Permission
Page12of42
226347869.xls.ms_office Security Level:
MAXCNTNUM MAX Consecutive HO Times BSC6900 SET GCELLHOAD(Optional) Number of consecutive intra-cell handovers allowed in a cell. When the interval between two intra-cell handovers is lower than a certain time threshold, these two intra-cell handovers are considered consecutive. When a certain number of intra-cell handovers occur consecutively, intra-cell handovers will be disallowed in the cell for a certain period of time. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 1~20 1~20 None None 3 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MaxDlAssRetryTimes Retry Times of Downlink TBF Reassignment BSC6900 SET BSCPSSOFTPARA(Optional) Maximum number of attempts to resend the downlink assignment messages. GBFD-114101GPRS Interval Type 0~5 0~5 None None 2 BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MaxDlEstRetryNum Retry Times of Downlink TBF Establishment BSC6900 SET BSCPSSOFTPARA(Optional) Number of attempts to re-establish the downlink TBF. GBFD-114101GPRS Interval Type 0~5 0~5 None None 1 BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MAXDROPPWRTHRESHOLD Max Drop Power Threshold BSC6900 SET BTSBAKPWR(Optional) Maximum degree by which the BTS can decrease the power of a TRX GBFD-111605Active Backup Power Control Interval Type 0~20 0~20 dB None 10 BTS This parameter is valid only when "BAKPWRSAVMETHOD" is set to BYPWR. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MAXFQNUM Maximum TRX Number BSC6900 ADD BTSAUTOPLAN(Mandatory)SET BTSAUTOPLANCFG(Optional) Maximum number of TRXs that can be configured for one cell. For the BTS3900B GSM, when the "Frequency and BSIC Plan Switch" is ON, the "Maximum TRX Number" (one or two, one by default) can be selected. For the BTS3900E GSM, when the "Capacity and Coverage Optimize Switch" is OFF, the "Maximum TRX Number" (one or two, one by default) can be selected. GBFD-510702Compact BTS Automatic Capacity Planning Interval Type 1~2 1~2 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MAXFQNUM1 Maximum TRX Number BSC6900 SET BTSAUTOPLANCFG(Optional) Maximum number of TRXs that can be configured for one cell. For the BTS3900B GSM, when the "Frequency and BSIC Plan Switch" is ON, the "Maximum TRX Number" (one or two, one by default) can be selected. For the BTS3900E GSM, when the "Capacity and Coverage Optimize Switch" is OFF, the "Maximum TRX Number" (one or two, one by default) can be selected. GBFD-510702Compact BTS Automatic Capacity Planning Interval Type 1~2 1~2 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MAXFRAMELEN Maximum Frame Length[byte] BSC6900 ADD IPMUX(Optional) Maximum multiplexing frame length. This parameter indicates the Maximum multiplexing frame length. GBFD-118604GBFD-118610 Abis MUXUDP MUX for A Transmission Interval Type 24~1059 24~1059 byte 1059 1059 IP path None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The adjacent node ID must be configured.
MAXLOADBTSNUM Max BTS Num of Parallel Software Load BSC6900 SET OTHSOFTPARA(Optional) Maximum number of BTSs that are allowed to concurrently download software under a BSC GBFD-111202O&M of BTS Interval Type 50~200 50~200 None None 100 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved 1. In the earlier versions of BSC6000V900R008C01B060SP06 and BSC6000V900R0086C01B060SP06, a maximum of 50 BTSs can be downloaded simultaneously on one BSC through the M2000 client. In BSC6000V900R008C01B060SP06 and BSC6000V900R0086C01B060SP06 and its later versions, a maximum of 100 BTSs can be downloaded simultaneously on one BSC through the M2000 client. Therefore, the number of BTSs to be downloaded should take the intersection of the value of this parameter and the number of BTSs supported by the M2000 client.2. If the BTS software versions downloaded simultaneously are excessive, the CPU usage of the OMU increases. In this case, the services are likely to be affected.
MAXMFLEN PPP mux max mux-frame length BSC6900 ADD PPPLNK(Optional) The value of this parameter cannot be less than the maximum PPPMUX sub-frame length (MUXMAXSFL). This parameter can be associated with the maximum segment length of the MP to control whether to segment the multiplexed MP. To enable the PPPMUX, the number of sub-frames must be more than or equal to 2. The following condition must be met: wMuxMaxSfL <= ( wMuxMfl-8 )/2. GBFD-118611GBFD-118622 Abis IP over E1/T1A IP over E1/T1 Interval Type 1~1500 1~1500 byte 256 256 PPP link None Read & Write Y PPP link Interrupt the service until negotiate successfully again. None
MAXMFLEN PPP mux max mux-frame length BSC6900 ADD MPGRP(Optional) The value of this parameter cannot be less than the maximum PPPMUX sub-frame length (MUXMAXSFL). This parameter can be associated with the maximum segment length of the MP to control whether to segment the multiplexed MP. To enable the PPPMUX, the number of sub-frames must be more than or equal to 2. The following condition must be met: wMuxMaxSfL <= ( wMuxMfl-8 )/2 GBFD-118611GBFD-118622 Abis IP over E1/T1A IP over E1/T1 Interval Type 1~1500 1~1500 byte None None MP groupNone Read & Write N (No impact on the UE in idle mode) Not involved Not involved The value of this parameter cannot be smaller than the maximum PPPMUX sub-frame length. The number sub-frame must be larger than 2 to enable the PPPMUX.
MaxMissTimes Maximum Retry Times BSC6900 SET PWDPOLICY(Optional) Maximum number of retries when the user logs in MRFD-210305Security Management Interval Type 1~255 1~255 None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
maxnum Max Alarm Log Number BSC6900 SET ALMCAPACITY(Optional) Maximum capacity for storing the alarm log MRFD-210304Faulty Management Interval Type 10000~150000 10000~150000 None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MAXOUTPUTPOWER Diesel max output power BSC6900 SET BTSDPMUBP(Optional) Maximum output power of the diesel GBFD-111202O&M of BTS Interval Type 1~1000 100~100000 (step: 100) W None 125 BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MAXPATHRETR Path max retrans BSC6900 ADD SCTPLNK(Optional) If the number of the path retransmissions exceeds this value, the parameter is deleted automatically. The value must be smaller than Association max retrans. None None Interval Type 0~254 0~254 None None 5(application type is NBAP), 2(application type is M3UA) SCTP linkThe value to be set should be smaller than the value of "MAXASSOCRETR" in "ADD SCTPLNK". Read & Write N (No impact on the UE in idle mode) Not involved Not involved The value should be smaller than "MAXASSOCRETR" in the command "ADD SCTPLNK".
MaxPbLinkChkNum Pb Link Check Max TimeOut Number BSC6900 SET OTHSOFTPARA(Optional) Retransmission times of Pb link check (LapdCheck) messages. When a BSC sends a Pb link check message to an external PCU and fails to receive a response from the external PCU, it retransmits the message. This parameter indicates the maximum times for the PB link check message to be transmitted. GBFD-114101GPRS Interval Type 0~100 0~100 None None 3 BSC6900This parameter is valid only when "TYPE" in "SET BSCPCUTYPE" is set to OUTER. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MAXPDCHNUM Maximum Number of PDCH BSC6900 SET GTRXBASE(Optional) Maximum number of PDCHs that can be assigned in the TRX GBFD-113101PDCH Dynamic Adjustment Interval Type 0~8 0~8 None None 8 TRX None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MAXPDCHRATE Maximum Rate Threshold of PDCHs in a Cell BSC6900 SET GCELLPSCHM(Optional) Maximum value of the PDCH ratio in a cell. The number of available TCHs and PDCHs in a cell is set to a fixed value. The PDCH ratio is: available PDCH/(TCH/F + static PDCH). This parameter is used to restrict the PDCH ratio. GBFD-113101PDCH Dynamic Adjustment Interval Type 0~100 0~100 per cent None 30 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MaxPollingRetryTimes Retry Times of Downlink TBF Polling BSC6900 SET BSCPSSOFTPARA(Optional) Maximum number of attempts to resend the polling messages. GBFD-114101GPRS Interval Type 0~5 0~5 None None 5 BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MAXRECHARGECURRENT Charge coefficient BSC6900 SET BTSPMUBP(Optional) Maximum current coefficient when the battery is charged. When the battery is charged, the maximum current can be 0.01 to 0.99 times of the capacity of the battery cabinet. That is, the charge coefficient is 0.01-0.99. For example, if the capacity of the battery cabinet is 200 A and the charge coefficient is 0.15, the maximum charge current for the battery cabinet is 30 A. GBFD-111202O&M of BTS Enumeration Type 1C(0.01C), 2C(0.02C), 3C(0.03C), 4C(0.04C), 5C(0.05C), 6C(0.06C), 7C(0.07C), 8C(0.08C), 9C(0.09C), 10C(0.10C), 11C(0.11C), 12C(0.12C), 13C(0.13C), 14C(0.14C), 15C(0.15C), 16C(0.16C), 17C(0.17C), 18C(0.18C), 19C(0.19C), 20C(0.20C), 21C(0.21C), 22C(0.22C), 23C(0.23C), 24C(0.24C), 25C(0.25C), 26C(0.26C), 27C(0.27C), 28C(0.28C), 29C(0.29C), 30C(0.30C), 31C(0.31C), 32C(0.32C), 33C(0.33C), 34C(0.34C), 35C(0.35C), 36C(0.36C), 37C(0.37C), 38C(0.38C), 39C(0.39C), 40C(0.40C), 41C(0.41C), 42C(0.42C), 43C(0.43C), 44C(0.44C), 45C(0.45C), 46C(0.46C), 47C(0.47C), 48C(0.48C), 49C(0.49C), 50C(0.50C), 51C(0.51C), 52C(0.52C), 53C(0.53C), 54C(0.54C), 55C(0.55C), 56C(0.56C), 57C(0.57C), 58C(0.58C), 59C(0.59C), 60C(0.60C), 61C(0.61C), 62C(0.62C), 63C(0.63C), 64C(0.64C), 65C(0.65C), 66C(0.66C), 67C(0.67C), 68C(0.68C), 69C(0.69C), 70C(0.70C), 71C(0.71C), 72C(0.72C), 73C(0.73C), 74C(0.74C), 75C(0.75C), 76C(0.76C), 77C(0.77C), 78C(0.78C), 79C(0.79C), 80C(0.80C), 81C(0.81C), 82C(0.82C), 83C(0.83C), 84C(0.84C), 85C(0.85C), 86C(0.86C), 8 1C, 2C, 3C, 4C, 5C, 6C, 7C, 8C, 9C, 10C, 11C, 12C, 13C, 14C, 15C, 16C, 17C, 18C, 19C, 20C, 21C, 22C, 23C, 24C, 25C, 26C, 27C, 28C, 29C, 30C, 31C, 32C, 33C, 34C, 35C, 36C, 37C, 38C, 39C, 40C, 41C, 42C, 43C, 44C, 45C, 46C, 47C, 48C, 49C, 50C, 51C, 52C, 53C, 54C, 55C, 56C, 57C, 58C, 59C, 60C, 61C, 62C, 63C, 64C, 65C, 66C, 67C, 68C, 69C, 70C, 71C, 72C, 73C, 74C, 75C, 76C, 77C, 78C, 79C, 80C, 81C, 82C, 83C, 84C, 85C, 86C, 87C, 88C, 89C, 90C, 91C, 92C, 93C, 94C, 95C, 96C, 97C, 98C, 99C None 15 None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MAXRECHARGECURRENT Charge Coefficient BSC6900 SET BTSDPMUBP(Optional) Maximum current coefficient when the battery is charged. When the battery is charged, the maximum current can be 0.05 to 0.25 times of the capacity of the battery cabinet. That is, the charge coefficient is 0.05-0.25. For example, if the capacity of the battery cabinet is 200 A and the charge coefficient is 0.15, the maximum charge current for the battery cabinet is 30 A.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. GBFD-111202O&M of BTS Enumeration Type 5C(0.05C), 7C(0.07C), 10C(0.10C), 12C(0.12C), 15C(0.15C), 18C(0.18C), 20C(0.2C), 22C(0.22C), 25C(0.25C) 5C, 7C, 10C, 12C, 15C, 18C, 20C, 22C, 25C None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MAXRESEND Max Resend Times of Phy.Info. BSC6900 SET GCELLHOAD(Optional) Maximum times for a Physical Information message to be transmitted. When the retransmission times exceeds this parameter and the BTS still cannot receive any correct SAMB frame from the MS, the BTS sends a connection failure message (including the handover failure information) to the BSC, which releases the assigned channel and stops timer T3105 after receiving this message. In a non-synchronized handover, an MS keeps sending Handover Access Burst messages (usually, the value of timer T3124 is 320 ms) to the network. When detecting these messages, the BTS returns a Physical Information message to the MS through the main DCCH (FACCH) channel, starts timer T3105, and sends a MSG_ABIS_HO_DETECT message to the BSC. The BTS includes the information of different physical layers in the Physical Information message, thus ensuring correct traffic transmission for the MS. If the timer timeouts before a SAMB frame is received from the MS, the BTS retransmits the Physical Information message to the MS. For details, se GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 1~255 1~255 None None 30 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved You can increase this value when the handovers are slow or the handover success ratio is low due to bad clock or transmission quality. For the handovers of an MS to succeed, the following condition must be met: "Physical information MAX Retrans" x "Radio link invalid count" > Interval between the EST IND message and the HO DETECT message (120 to 180 ms); otherwise the handovers will fail for sure.
MAXRETRANS1 Max Retransmissions for Radio Priority 1 BSC6900 SET GCELLPRACH(Optional) Maximum retransmission for radio priority 1. The 2bit Radio Priority message carried by the MS in the Packet Channel Request message has four levels of priorities. Level 1 is the highest priority, and level 4 is the lowest priority. GBFD-119110Access Enumeration Type 1_Times(1_Times), 2_Times(2_Times), 4_Times(4_Times), 7_Times(7_Times) 1_Times, 2_Times, 4_Times, 7_Times None None 7_Times Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MAXRETRANS2 Max Retransmissions for Radio Priority 2 BSC6900 SET GCELLPRACH(Optional) Maximum retransmission for radio priority 2. The 2bit Radio Priority message carried by the MS in the Packet Channel Request message has four levels of priorities. Level 1 is the highest priority, and level 4 is the lowest priority. GBFD-119110Access Enumeration Type 1_Times(1_Times), 2_Times(2_Times), 4_Times(4_Times), 7_Times(7_Times) 1_Times, 2_Times, 4_Times, 7_Times None None 7_Times Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MAXRETRANS3 Max Retransmissions for Radio Priority 3 BSC6900 SET GCELLPRACH(Optional) Maximum retransmission for radio priority 3. The 2bit Radio Priority message carried by the MS in the Packet Channel Request message has four levels of priorities. Level 1 is the highest priority, and level 4 is the lowest priority. GBFD-119110Access Enumeration Type 1_Times(1_Times), 2_Times(2_Times), 4_Times(4_Times), 7_Times(7_Times) 1_Times, 2_Times, 4_Times, 7_Times None None 7_Times Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MAXRETRANS4 Max Retransmissions for Radio Priority 4 BSC6900 SET GCELLPRACH(Optional) Maximum retransmission for radio priority 4. The 2bit Radio Priority message carried by the MS in the Packet Channel Request message has four levels of priorities. Level 1 is the highest priority, and level 4 is the lowest priority. GBFD-119110Access Enumeration Type 1_Times(1_Times), 2_Times(2_Times), 4_Times(4_Times), 7_Times(7_Times) 1_Times, 2_Times, 4_Times, 7_Times None None 7_Times Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MAXSFLEN PPP mux max sub-frame length BSC6900 ADD PPPLNK(Optional) Maximum PPPMUX sub-frame length. If the PPP frame length is larger than this value, the PPPMUX multiplexing is performed. The value of this parameter cannot be larger than the maximum multiplexed frame length wMuxMfl. To enable the PPPMUX, the number of sub-frames must be more than or equal to 2. The following condition must be met: wMuxMaxSfL <= ( wMuxMfl-8 )/2 GBFD-118611GBFD-118622 Abis IP over E1/T1A IP over E1/T1 Interval Type 1~746 1~746 byte 64 64 PPP link None Read & Write Y PPP link Interrupt the service until negotiate successfully again. None
MAXSFLEN PPP mux max sub-frame length BSC6900 ADD MPGRP(Optional) Maximum PPPMUX sub-frame length. If the PPP frame length is larger than this value, the PPPMUX multiplexing is performed. The value of this parameter cannot be larger than the maximum multiplexed frame length wMuxMfl. To enable the PPPMUX, the number of sub-frames must be more than or equal to 2. The following condition must be met: wMuxMaxSfL<=( wMuxMfl-8 )/2 GBFD-118611GBFD-118622 Abis IP over E1/T1A IP over E1/T1 Interval Type 1~746 1~746 byte None None MP groupNone Read & Write N (No impact on the UE in idle mode) Not involved Not involved If the PPP frame length is larger than this value, PPPMUX multiplexing cannot be performed. The value of this parameter cannot be larger than the maximum multiplexing frame length wMuxMfl and the number sub-frame must be larger than 2 as the enabling condition of PPPMUX (the relation between the maximum sub-frame length and the maximum multiplexing frame length is: MuxMaxSfL<=(wMuxMfl-8)/2 ).
MAXSTEP0 MAX Down Adj.Value Qual.Zone 0 BSC6900 SET GCELLPWR2(Optional) Huawei power control algorithm II divides three quality zones according to the quality of the receive signals. When the power is downwardly adjusted according to the level, the maximum downward adjustment step can vary according to the quality of the received signals. This parameter specifies the maximum step of downward power adjustment when the quality of the received signals falls into quality zone 0. GBFD-110703Enhanced Power Control Algorithm Interval Type 0~30 0~30 dB None 2 Cell This parameter is valid when "PWRCTRLSW" in the "SET GCELLPWRBASIC" command is set to PWR2. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MAXSTEP1 MAX Down Adj.Value Qual.Zone 1 BSC6900 SET GCELLPWR2(Optional) Huawei power control algorithm II divides three quality zones according to the quality of the receive signals. When the power is downwardly adjusted according to the level, the maximum downward adjustment step can vary according to the quality of the received signals. This parameter specifies the maximum step of downward power adjustment when the quality of the received signals falls into quality zone 1. GBFD-110703Enhanced Power Control Algorithm Interval Type 0~30 0~30 dB None 0 Cell This parameter is valid when "PWRCTRLSW" in the "SET GCELLPWRBASIC" command is set to PWR2. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MAXSTEP2 MAX Down Adj.Value Qual.Zone 2 BSC6900 SET GCELLPWR2(Optional) Huawei power control algorithm II divides three quality zones according to the quality of the receive signals. When the power is downwardly adjusted according to the level, the maximum downward adjustment step can vary according to the quality of the received signals. This parameter specifies the maximum step of downward power adjustment when the quality of the received signals falls into quality zone 2. GBFD-110703Enhanced Power Control Algorithm Interval Type 0~30 0~30 dB None 0 Cell This parameter is valid when "PWRCTRLSW" in the "SET GCELLPWRBASIC" command is set to PWR2. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MAXTA Max TA BSC6900 SET GCELLBASICPARA(Optional) Maximum time advance (TA). The value of this parameter is related to that of "Cell Extension Type" in the "ADD GCELL" command. GBFD-110901Adjustment of Adaptive Timing Advance Interval Type 0~255 0~255 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved If this parameter is set to a smaller value, the handover success rate may be affected.
MAXTADROPCALLFILTER MAX TA Drop Call Filter BSC6900 SET GCELLCCAD(Optional) Number of measurement reports (MRs) used for averaging the time advance before the call drops GBFD-111004Radio Dedicated Channel Management Interval Type 0~31 0~31 None None 20 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MAXTADROPCALLSWITCH Max TA Drop Call Switch BSC6900 SET GCELLCCAD(Optional) Whether to initiate a forcible call drop when the time advance exceeds "MAX TA Drop Call Threshold" GBFD-111004Radio Dedicated Channel Management Enumeration Type OFF(Off), ON(On) OFF, ON None None OFF Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MAXTADROPCALLTHRESHOLD MAX TA Drop Call Threshold BSC6900 SET GCELLCCAD(Optional) Whether the time advance after filtering exceeds the threshold. If the threshold is exceeded, a forcible call drop is initiated. GBFD-111004Radio Dedicated Channel Management Interval Type 0~255 0~255 None None 255 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MAXTSOCP Maximum Number of Occupied Abis Timeslots BSC6900 SET GTRXBASE(Optional) Maximum number of (16 kbit/s) Abis timeslots that the PDCHs can use in the TRX GBFD-117301Flex Abis Interval Type 0~32 0~32 None None 32 TRX None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MAXTTL MAX TTL BSC6900 TRC IPADDR(Optional) Maximum TTL value of the sent TRACERT packet None None Interval Type 2~255 2~255 None 16 16 None None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
MAXVALADJRX MAX Up Adj. PC Value by RX_LEV BSC6900 SET GCELLPWR2(Optional) Step of upward power adjustment according to the quality of the received signals GBFD-110703Enhanced Power Control Algorithm Interval Type 0~32 0~32 dB None 8 Cell This parameter is valid when "PWRCTRLSW" in the "SET GCELLPWRBASIC" command is set to PWR2. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MBFDCHKN MBFD Check Index BSC6900 ADD IPRTBIND(Mandatory) Detection index. The index is a unique value ranging from 0 to 31 if it is not specified. GBFD-118609IP Fault Detection Based on BFD Interval Type 0~511 0~511 None None None None None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
MBFDLOCALIP Multi hop BFD detect local ip BSC6900 STR IPCHK(Mandatory) Local IP address for multi-hop BFD GBFD-118609IP Fault Detection Based on BFD IP Address Type None 0.0.0.0~255.255.255.255 None None None None None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
MBMSCCHDL UMTS MBMS common channel service downlink factor BSC6900 ADD TRMFACTOR(Optional) WCDMA MBMS general common channel service downlink factor None None Interval Type 0~100 0~100 per cent 100 100 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node that is configured with the factor table. After the successful modification, the parameter takes effect in the following two cases:1. New access subscriber. 2. Bandwidth modification of the existing subscriber
MBR Multi-band report BSC6900 SET GCELLCCBASIC(Optional) Used for requesting the MS to report the measurement information of neighboring cells in multiple frequency bands. This parameter is carried in the system information 2ter and 5ter. GBFD-114401Multi-band Sharing One BSC Interval Type 0~3 0~3 None None If the traffic volume on each frequency band is even and there is no special requirements for the frequency band, the recommended value is 0; if the traffic volume on each frequency band is significantly uneven and a frequency band is preferred for an MS, the recommended value is 3; if traffic volume on each frequency band is not extremely uneven, the recommended value is 1 or 2. For details, see the GSM Rec. 05. 08. Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MBSIGNLEN Filter length for sdcch mean_bep BSC6900 SET GCELLHOFITPEN(Optional) For the purpose of accurately reflecting the radio environment of a network, filtering is performed on the measured values in several consecutive measurement reports. This parameter indicates the number of enhanced measurement reports received on a signaling channel used to measure the MEAN_BEP value. GBFD-117501Enhanced Measurement Report(EMR) Interval Type 0~31 0~31, step:480 for TCH and 470 for SDCCH ms None 2 Cell This parameter is valid only when "MEASURETYPE" in "SET GCELLCCUTRANSYS" is set to EnhMeasReport. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MBTRAFFLEN Filter length for tch mean_bep BSC6900 SET GCELLHOFITPEN(Optional) For the purpose of accurately reflecting the radio environment of a network, filtering is performed on the measured values in several consecutive measurement reports. This parameter indicates the number of enhanced measurement reports received on a voice channel used to measure the MEAN_BEP value. GBFD-117501Enhanced Measurement Report(EMR) Interval Type 0~31 0~31, step:480 for TCH and 470 for SDCCH ms None 6 Cell This parameter is valid only when "MEASURETYPE" in "SET GCELLCCUTRANSYS" is set to EnhMeasReport. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MBTSID Second BTS Index BSC6900 COL SYNCINFO(Mandatory) Number of the BTS. The BTS is numbered uniquely in a BSC. GBFD-118201Soft-Synchronized Network Interval Type 0~2047 0~2047 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None.
MBTSNAME Second BTS Name BSC6900 COL SYNCINFO(Mandatory) Name of the BTS. The BTS is named uniquely in a BSC. GBFD-118201Soft-Synchronized Network String Type None 1~64 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None.
MCC MCC BSC6900 ADD GCNOPERATOR(Mandatory)ADD GCELL(Mandatory)ADD GEXT2GCELL(Mandatory)ADD GEXT3GCELL(Mandatory)SET FHO(Mandatory)ADD GCELLQUICKSETUP(Mandatory)ADD BTSAUTOPLAN(Mandatory)SET BTSAUTOPLANCFG(Optional) Mobile country code. This parameter identifies the country where a mobile subscriber is located, for example, the Chinese MCC is 460. MRFD-210301Configuration Management String Type None 3 digit None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MCC1 Cell MCC BSC6900 SET BTSAUTOPLANCFG(Optional) Local mobile country code (MCC). It is used to identify the country that the mobile subscriber belongs to. For example, the MCC of China is 460. GBFD-510702Compact BTS Automatic Capacity Planning String Type None 1~3 characters None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MCCLASS MC PRI number BSC6900 ADD MPGRP(Optional) MC priority number. This parameter is valid when the MP group type is MC.4(Use two bytes to present MC priority number, 4 classes), 8(Use four bytes to present MC priority number, 8 classes) GBFD-118611GBFD-118622 Abis IP over E1/T1A IP over E1/T1 Interval Type 4,8 4, 8 None None 8 MP groupNone Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MCCLASS MC PRI number BSC6900 ADD BTSMPGRP(Optional) MC priority number. GBFD-118611Abis IP over E1/T1 Interval Type 4,8 4(Use two bytes to present MC priority number, 4 classes), 8(Use four bytes to present MC priority number, 8 classes) None None 8 BTS This parameter is required when "MLPPP type" is set to "MCPPP" with the "ADD MPGRP". Read & Write Y PPP link Less than 5 minutes None
MCELLID Second Cell Index BSC6900 ADD NCELL(Mandatory)COL SYNCINFO(Mandatory) Number of the cell. The cell is numbered uniquely in a BSC. MRFD-210301Configuration Management Interval Type 0~2047 0~2047 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None.
MCELLNAME Second Cell Name BSC6900 ADD NCELL(Mandatory)COL SYNCINFO(Mandatory) Name of cell 2.GBFD-111202O&M of BTS String Type None 1~64 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None.
MCN Cabinet No. of Management Board BSC6900 SET BTSFMUABP(Optional)SET BTSAPMUBP(Optional)SET BTSDATUBP(Optional)SET BTSDEMUBP(Optional)SET BTSDHEUBP(Optional) Cabinet No. of the management board. The management board refers to the TMU or RXU that directly communicates with the board. The configuration of this parameter must be consistent with the actual physical connection. Otherwise, the board may not work properly. GBFD-111202O&M of BTS Interval Type 0~62 0~62 None None None BTS "BTSTYPE" identifies the value range of this parameter. The number of cabinets supported by the BTS depends on the type of the BTS. For details, see the parameter description of the command. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MCSTANDARD GSM Multi Carrier BTS Standard BSC6900 SET BTSPSUFP(Optional) Standard for the GSM multi-carrier BTS GBFD-111202O&M of BTS Enumeration Type CLASS0(Class0), CLASS1(Class1), CLASS2(Class2) CLASS0, CLASS1, CLASS2 None CLASS0 None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MDIDX MD INDEX BSC6900 ADD ETHMD(Mandatory)ADD ETHMA(Mandatory) Identifies a maintenance domain. GBFD-118630Ethernet OAM Interval Type 0~7 0~7 None None None Board None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
MDLEVEL MD LEVEL BSC6900 ADD BTSETHMD(Optional) Level of the maintenance domain. GBFD-118630MRFD-210301 Ethernet OAMConfiguration Management Interval Type 0~7 0~7 None None None Ethernet port None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
MDName MD NAME BSC6900 ADD ETHMD(Mandatory)PING BTSCFM(Mandatory)TRC BTSCFM(Mandatory) name of the MDGBFD-118630Ethernet OAM String Type None 1~20 characters None None None Ethernet port None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
MDNAME MD NAME BSC6900 ADD BTSETHMD(Mandatory)ADD BTSETHMA(Mandatory)ADD BTSETHLCMEP(Mandatory)ADD BTSETHRMMEP(Mandatory) Name of the maintenance domain. GBFD-118630MRFD-210301 Ethernet OAMConfiguration Management String Type None 1~20 characters None None None Ethernet port None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
MEASORDER Allow MR Command or not BSC6900 SET GCELLPSI1(Optional) Whether to allow the MS to the send the PS measurement report to the network side. GBFD-119102Packet System Information Enumeration Type NO(No), YES(Yes)NO, YES None None NO Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MEASPERIOD Measurement Period BSC6900 ADD GNRNC(Mandatory) Common measurement period. MRFD-211402MBSC Load Balancing Interval Type 1~5 {1~5} s 3 None BSC Set when Allow Common Measurement at Iur-g is set to Yes Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MEASURETYPE Measurement Report Type BSC6900 SET GCELLCCUTRANSYS(Optional) Type of the measurement report (MR) reported by the MS GBFD-117501Enhanced Measurement Report(EMR) Enumeration Type EnhMeasReport(Enhanced Measurement Report), ComMeasReport(Common Measurement Report) EnhMeasReport, ComMeasReport None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The Enhanced Measurement Report supports the measurement of 3G neighboring cells to implement the interoperability between the 2G system and 3G system, and thus ensures the service continuity.
MEPID MEP ID BSC6900 ADD ETHMEP(Mandatory) Identifies a maintenance point in the maintenance allianceA maintenance point is an edge node of the MA. GBFD-118630Ethernet OAM Interval Type 1~1000 1~1000 None None None Ethernet port None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
MEPID MEP ID BSC6900 ADD BTSETHLCMEP(Mandatory)ADD BTSETHRMMEP(Mandatory) Identifies a maintenance end point (MEP) of a maintenance association. GBFD-118630MRFD-210301 Ethernet OAMConfiguration Management Interval Type 1~400 1~400 None None None Ethernet port None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
MEPTYPE MEP Type BSC6900 ADD ETHMEP(Mandatory) The type of the maintenance point added to the maintenance group. LocalMep indicates a local maintenance point and RemoteMep indicates a remote maintenance point. GBFD-118630Ethernet OAM Enumeration Type LocalMep(LocalMep), RemoteMep(RemoteMep) LocalMep, RemoteMepNone None None Ethernet port None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MHF MP/MC list head option BSC6900 ADD MPGRP(Optional) MP/MC sequence header option GBFD-118611GBFD-118622 Abis IP over E1/T1A IP over E1/T1 Enumeration Type LONG(LONG), SHORT(SHORT) LONG, SHORT None LONG LONG MP groupNone Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MHF MP/MC list head option BSC6900 ADD BTSMPGRP(Optional) Head option of an MP/MC list GBFD-118611Abis IP over E1/T1 Enumeration Type LONG, SHORT LONG, SHORT None LONG LONG BTS None Read & Write Y PPP link Less than 5 minutes None
MINACCRXLEV Cell Reselection Level Threshold BSC6900 SET GCELLNC2PARA(Optional) Minimum receiving level for a candidate cell during cell reselection. GBFD-116201Network-Controlled Cell Reselection (NC2) Interval Type 0~63 0~63 dB None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MINBW Min bandwidth [64kbps] BSC6900 ADD IPLOGICPORT(Mandatory) Minimum bandwidth for dynamic adjustment at the logical port None None Interval Type 1~1000 64~64000, step:64 kbit/s None None IP logical port None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MINECNOTHRES Min Ec/No threshold BSC6900 ADD GEXT3GCELL(Optional) Selects 3G candidate cells. If the measured value of a 3G neighboring cell is lower than this threshold, the 3G neighboring cell will be removed from among the 3G candidate cells. GBFD-114301GSM/WCDMA Interoperability Interval Type 0~49 0~49 dB None 10 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MINOFFSET Min Access Level Offset BSC6900 ADD G2GNCELL(Optional) Minimum receive level offset GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 0~63 0~63 dB None 0 Cell This parameter is based on "HOCDCMINDWPWR" and "HOCDCMINUPPWR". Different offset can be set for different neighboring cells. The following condition must be met for a neighboring cell to be added into the candidate cell queue: Neighboring cell uplink level >= ("HOCDCMINUPPWR" + "MINOFFSET"); Neighboring cell downlink level >= ("HOCDCMINDWPWR" + "MINOFFSET"). Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MinorAlmThdA ANT_A ALD Current Minor Alarm Occur Th BSC6900 SET BTSRXUBP(Optional) Threshold for triggering prompt alarm clearance when the ANT_A tributary antenna current is too heavy. When the actual current is higher than the configured value, the ALD Current Prompt Alarm clearance is triggered. MRFD-210304Faulty Management Interval Type 10~3500 10~3500 mA 170 None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MinorAlmThdB ANT_B ALD Current Minor Alarm Occur Th BSC6900 SET BTSRXUBP(Optional) Threshold for triggering prompt alarm clearance when the ANT_B tributary antenna current is too heavy. When the actual current is higher than the configured value, the ALD Current Prompt Alarm clearance is triggered. MRFD-210304Faulty Management Interval Type 10~3500 10~3500 mA 170 None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MINORALMUP0 Feed Tri. 0 TMA Over Warning Alm Thred. BSC6900 SET BTSDATUBP(Optional) Warning alarm threshold against excessive TMA feed current of feed tributary 0. When the actual current is greater than the specified value, a TMA feed current warning alarm is generated. MRFD-210304Faulty Management Interval Type 0~2000 0~2000 mA None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MINORALMUP1 Feed Tri. 1 TMA Over Warning Alm Thred. BSC6900 SET BTSDATUBP(Optional) Warning alarm threshold against excessive TMA feed current of feed tributary 1. When the actual current is greater than the specified value, the TMA feed current warning alarm is generated. MRFD-210304Faulty Management Interval Type 0~2000 0~2000 mA None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MINORALMUP2 Feed Tri. 2 TMA Over Warning Alm Thred. BSC6900 SET BTSDATUBP(Optional) Warning alarm threshold against excessive TMA feed current of feed tributary 2. When the actual current is greater than the specified value, the TMA feed current warning alarm is generated. MRFD-210304Faulty Management Interval Type 0~2000 0~2000 mA None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MINORALMUP3 Feed Tri. 3 TMA Over Warning Alm Thred. BSC6900 SET BTSDATUBP(Optional) Warning alarm threshold against excessive TMA feed current of feed tributary 3. When the actual current is greater than the specified value, the TMA feed current warning alarm is generated. MRFD-210304Faulty Management Interval Type 0~2000 0~2000 mA None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MINORALMUP4 Feed Tri. 4 TMA Over Warning Alm Thred. BSC6900 SET BTSDATUBP(Optional) Warning alarm threshold against excessive TMA feed current of feed tributary 4. When the actual current is greater than the specified value, the TMA feed current warning alarm is generated. MRFD-210304Faulty Management Interval Type 0~2000 0~2000 mA None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MINORALMUP5 Feed Tri. 5 TMA Over Warning Alm Thred. BSC6900 SET BTSDATUBP(Optional) Warning alarm threshold against excessive TMA feed current of feed tributary 5. When the actual current is greater than the specified value, the TMA feed current warning alarm is generated. MRFD-210304Faulty Management Interval Type 0~2000 0~2000 mA None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MinorClrThdA ANT_A ALD Current Minor Alarm Clear Th BSC6900 SET BTSRXUBP(Optional) Threshold for triggering prompt alarm clearance when the ANT_A tributary antenna current is too heavy. When the actual current is lower than the configured value, the ALD Current Prompt Alarm clearance is triggered. MRFD-210304Faulty Management Interval Type 10~3500 10~3500 mA 140 None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MinorClrThdB ANT_B ALD Current Minor Alarm Clear Th BSC6900 SET BTSRXUBP(Optional) Threshold for triggering prompt alarm clearance when the ANT_B tributary antenna current is too heavy. When the actual current is lower than the configured value, the ALD Current Prompt Alarm clearance is triggered. MRFD-210304Faulty Management Interval Type 10~3500 10~3500 mA 140 None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MINPWRLEVDIRTRY Min Power Level For Directed Retry BSC6900 SET GCELLHOCTRL(Optional) In a direct retry, when the receive level of a neighboring cell is no smaller than this parameter, the neighboring cell can be a candidate cell for the direct retry. GBFD-110607Direct Retry Interval Type 0~63 0~63 dB None 16 Cell This parameter is valid only when "HOCTRLSWITCH" is set to HOALGORITHM1. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MINRESTIMETCH TCH Minimum Recovery Time BSC6900 SET GCELLCHMGBASIC(Optional) Minimum time required for a TCH to transform to a SDCCH and then transform back to a TCH GBFD-113001SDCCH Dynamic Adjustment Interval Type 60~3600 60~3600 s None 60 Cell This parameter is valid only when "SDDYN" in "SET GCELLBASICPARA" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MINRSCPTHRES Min RSCP threshold BSC6900 ADD GEXT3GCELL(Optional) Selects 3G candidate cells. If the measured value of a 3G neighboring cell is lower than this threshold, the 3G neighboring cell will be removed from among the 3G candidate cells. GBFD-114301GBFD-114302 GSM/WCDMA InteroperabilityGSM/TD-SCDMA Interoperability Interval Type 0~63 0~63 dB None 10 Cell A 3G cell can be added into the candidate cell queue when the following conditions are met: "INTERRATOUTBSCHOEN" is set to YES; "BET3GHOEN" is set to YES; the RSCP of the 3G cell for a period of time is greater than the sum of "HORSCPTH3G" and "RSCPOFF". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MINRXINT Min interval of BFD packet receive [ms] BSC6900 STR IPCHK(Optional) Minimum interval between received BFD packets GBFD-118609IP Fault Detection Based on BFD Interval Type 10~1000 10~1000 ms 30 30 Ethernet port None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
MINRXINTERVAL Minimum RX Interval BSC6900 ADD BTSBFD(Optional) Minimum interval at which the BTS receives BFD packets GBFD-118609IP Fault Detection Based on BFD Interval Type 10~1000 10~1000 ms 100 100 Current BFD session None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MINTXINT Min interval of BFD packet send [ms] BSC6900 STR IPCHK(Optional) Minimum interval between sent BFD packets GBFD-118609IP Fault Detection Based on BFD Interval Type 10~1000 10~1000 ms 30 30 Ethernet port None Read & Write N (No impact on the UE in idle mode) Not involved Not involved To modify this parameter, run "STP GATEWAYCHK" first and then "STR GATEWAYCHK".
MINTXINTERVAL Minimum TX Interval BSC6900 ADD BTSBFD(Optional) Minimum interval at which the BTS sends BFD packets GBFD-118609IP Fault Detection Based on BFD Interval Type 10~1000 10~1000 ms 100 100 Current BFD session None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MIRRORDPN Mirror Dest Port No. BSC6900 STR ETHMIRRORPORT(Mandatory) Mirror destination Ethernet port number None None Interval Type 0~11 0~11 None None None Ethernet port None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
MIRRORSPN Mirror Source Port No. BSC6900 STR ETHMIRRORPORT(Mandatory) Mirror Ethernet port number None None Interval Type 0~11 0~11 None None None Ethernet port None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
MIRRORTYPE Mirror Type BSC6900 STR ETHMIRRORPORT(Mandatory) Mirror type None None Enumeration Type UP(upstream mirror), DOWN(downstream mirror) UP, DOWN None None None Ethernet port None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MNC MNC BSC6900 ADD GCNOPERATOR(Mandatory)ADD GCELL(Mandatory)ADD GEXT2GCELL(Mandatory)ADD GEXT3GCELL(Mandatory)SET FHO(Mandatory)ADD GCELLQUICKSETUP(Mandatory)ADD BTSAUTOPLAN(Mandatory)SET BTSAUTOPLANCFG(Optional) Mobile network code. This parameter identifies the public land mobile network (PLMN) where a mobile subscriber is homed. MRFD-210301Configuration Management String Type None 2~3 digit None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MNC1 Cell MNC BSC6900 SET BTSAUTOPLANCFG(Optional) Mobile network code (MNC). It is used to identify the PLMN that the mobile subscriber belongs to. GBFD-510702Compact BTS Automatic Capacity Planning String Type None 1~64 characters None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MOCACCESSCPURATE MOC Access CPU Rate BSC6900 SET BSCFCPARA(Optional) Usage threshold of the CPU for calling access. If the usage of the CPU exceeds the threshold, the calling access request is transferred to other CPU for processing. GBFD-111705GSM Flow Control Interval Type 50~95 50~95 per cent None 80 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MODE System clock working mode BSC6900 SET CLKMODE(Mandatory) Working mode of the system clock. Working modes of the system clock are as follows:(1) MANUAL: In this mode, you must specify a clock source and prevent the switching of the clock source.(2) AUTO: In this mode, you do not need to specify a clock source and the system automatically selects the clock source with the highest priority.(3) FREE: In this mode, the crystal oscillator of GCGa or GCUa board is used. MRFD-210502BSC/RNC Clock Enumeration Type MANUAL(Manual Handover), AUTO(Auto Handover), FREE(Free-run) MANUAL, AUTO, FREENone None AUTO BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MODE Signalling link mode BSC6900 ADD SCTPLNK(Mandatory) SCTP link work mode. Server mode: BSC starts the listening and waits for the peer to sending the SCTP-INIT message. Client mode: BSC actively sends the SCTP-INIT message. None None Enumeration Type SERVER(SERVER MOD), CLIENT(CLIENT MOD) SERVER, CLIENT None None None SCTP linkNone Read & Write Y SCTP link The services are interrupted until the SCTP link is working normally. The local end of the SCTP link is the server and the application type is NBAP, the working mode should not be modified as the client.For the SCTP link of the M3UA application, the working mode can be modified only when the upper layer application is deleted.
MODE Configure Mode BSC6900 SET QUICKCFG(Mandatory) configuration mode. MRFD-210301Configuration Management Enumeration Type OFF, ON OFF, ON None None OFF BSC6900None Read & Write Not involved Not involved Not involved None
MODE Mode after Switchover BSC6900 SWP MBSCMODE(Mandatory)CHK MODEDATA(Mandatory) Working mode after switchover MRFD-210301Configuration Management Enumeration Type GO(GSM), UO(UMTS), GU(GSM and UMTS) GO, UO, GU None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MODE Backup mode BSC6900 SET MSP(Optional) Backup mode of the switch protection group GBFD-111701Board Switchover Enumeration Type MODE1(1:1 Protection Switching), MODE2(1+1 Unidirectional Protection Switching), MODE3(1+1 Bidirectional Protection Switching) MODE1, MODE2, MODE3 None None None MSP protect group None Read & Write Y BSC6900 If the mode is not consistent, will interrupt service until it is consistent. The setting of this parameter must be negotiated with that on the interconnected side.
MODE Check mode BSC6900 STR IPCHK(Optional) Port working mode. When this parameter is set to CHECK_ON_STANDBY_PORT, it indicates that the connectivity check is performed on the standby port. When this parameter is set to CHECK_ON_INDEPENDENT_PORT, it indicates that the connectivity check is performed on the independent port. When this parameter is set to CHECK_ON_PRIMARY_PORT, it indicates that the connectivity check is performed on the active port. GBFD-118609IP Fault Detection Based on BFD Enumeration Type CHECK_ON_INDEPENDENT_PORT, CHECK_ON_PRIMARY_PORT, CHECK_ON_STANDBY_PORT CHECK_ON_INDEPENDENT_PORT, CHECK_ON_PRIMARY_PORT, CHECK_ON_STANDBY_PORT None None None None None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
MODE0 Feed Tri. 0 Alarm Mode BSC6900 SET BTSDATUBP(Optional) Alarm mode of feed tributary 0. There are three alarm modes. Alarm mode 1 has only one type of alarms. The alarm current is fixed and greater than the normal working current. Alarm mode 2 has two types of alarms: warning alarms and critical alarms. The alarm current is fixed and greater than the normal working current. Alarm mode 3 has two types of alarms: warning alarms and critical alarms. The warning alarm current is periodical pulse current, while the critical alarm current is fixed. MRFD-210304Faulty Management Enumeration Type MODE1(Mode1), MODE2(Mode2), MODE3(Mode3) MODE1, MODE2, MODE3 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MODE1 Feed Tri. 1 Alarm Mode BSC6900 SET BTSDATUBP(Optional) Alarm mode of feed tributary 1. There are three alarm modes. Alarm mode 1 has only one type of alarms. The alarm current is fixed and greater than the normal working current. Alarm mode 2 has two types of alarms: warning alarms and critical alarms. The alarm current is fixed and greater than the normal working current. Alarm mode 3 has two types of alarms: warning alarms and critical alarms. The warning alarm current is periodical pulse current, while the critical alarm current is fixed. MRFD-210304Faulty Management Enumeration Type MODE1(Mode1), MODE2(Mode2), MODE3(Mode3) MODE1, MODE2, MODE3 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MODE2 Feed Tri. 2 Alarm Mode BSC6900 SET BTSDATUBP(Optional) Alarm mode of feed tributary 2. There are three alarm modes. Alarm mode 1 has only one type of alarms. The alarm current is fixed and greater than the normal working current. Alarm mode 2 has two types of alarms: warning alarms and critical alarms. The alarm current is fixed and greater than the normal working current. Alarm mode 3 has two types of alarms: warning alarms and critical alarms. The warning alarm current is periodical pulse current, while the critical alarm current is fixed. MRFD-210304Faulty Management Enumeration Type MODE1(Mode1), MODE2(Mode2), MODE3(Mode3) MODE1, MODE2, MODE3 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MODE3 Feed Tri. 3 Alarm Mode BSC6900 SET BTSDATUBP(Optional) Alarm mode of feed tributary 3. There are three alarm modes. Alarm mode 1 has only one type of alarms. The alarm current is fixed and greater than the normal working current. Alarm mode 2 has two types of alarms: warning alarms and critical alarms. The alarm current is fixed and greater than the normal working current. Alarm mode 3 has two types of alarms: warning alarms and critical alarms. The warning alarm current is periodical pulse current, while the critical alarm current is fixed. MRFD-210304Faulty Management Enumeration Type MODE1(Mode1), MODE2(Mode2), MODE3(Mode3) MODE1, MODE2, MODE3 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MODE4 Feed Tri. 4 Alarm Mode BSC6900 SET BTSDATUBP(Optional) Alarm mode of feed tributary 4. There are three alarm modes. Alarm mode 1 has only one type of alarms. The alarm current is fixed and greater than the normal working current. Alarm mode 2 has two types of alarms: warning alarms and critical alarms. The alarm current is fixed and greater than the normal working current. Alarm mode 3 has two types of alarms: warning alarms and critical alarms. The warning alarm current is periodical pulse current, while the critical alarm current is fixed. MRFD-210304Faulty Management Enumeration Type MODE1(Mode1), MODE2(Mode2), MODE3(Mode3) MODE1, MODE2, MODE3 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MODE5 Feed Tri. 5 Alarm Mode BSC6900 SET BTSDATUBP(Optional) Alarm mode of feed tributary 5. There are three alarm modes. Alarm mode 1 has only one type of alarms. The alarm current is fixed and greater than the normal working current. Alarm mode 2 has two types of alarms: warning alarms and critical alarms. The alarm current is fixed and greater than the normal working current. Alarm mode 3 has two types of alarms: warning alarms and critical alarms. The warning alarm current is periodical pulse current, while the critical alarm current is fixed. MRFD-210304Faulty Management Enumeration Type MODE1(Mode1), MODE2(Mode2), MODE3(Mode3) MODE1, MODE2, MODE3 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MODULE MODULE NAME BSC6900 SET LOGCFG(Mandatory) MODULE NAME MRFD-210304Faulty Management Enumeration Type moniter~1host_gate~2ems_gate~3authority~4configure~5maintain~6stat~7alarm~8software~9ftp_server~10sntp~11btsom~12ems_agent~13omu_manager~14weblmt~15cfa~16debug_log moniter~1host_gate~2ems_gate~3authority~4configure~5maintain~6stat~7alarm~8software~9ftp_server~10sntp~11btsom~12ems_agent~13omu_manager~14weblmt~15cfa~16debug_log~17 None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MONITORPERIOD Monitor Period BSC6900 STR BTSRACKTEMPMON(Mandatory) Monitoring period GBFD-111202O&M of BTS Enumeration Type 30MINS(30 Minutes), 60MINS(60 Minutes), 120MINS(120 Minutes), 240MINS(240 Minutes) 30MINS, 60MINS, 120MINS, 240MINS None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MONITORTIME Monitor Time BSC6900 STR BTSRACKTEMPMON(Mandatory) Monitoring duration GBFD-111202O&M of BTS Interval Type 1~1440 1~1440 h None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
Month Month BSC6900 SET BTSAUTODLDACTINFO(Mandatory) Month when the TMU board software is released GBFD-111202O&M of BTS Interval Type 1~12 1~12 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MOVESPEEDTHRES Quick move speed thres BSC6900 SET GCELLHOFAST(Optional) A quick handover can be initiated only if the rate of an MS is higher than this parameter during a certain period of time. GBFD-510102Fast Move Handover Interval Type 0~600 0~600 m/s None 35 Cell This parameter is valid only when "QUICKHOEN" in "SET GCELLHOBASIC" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MPGRPN MP Group No. BSC6900 ADD MPGRP(Mandatory)ADD MPLNK(Mandatory) MP group number GBFD-118611GBFD-118622 Abis IP over E1/T1A IP over E1/T1 Interval Type 0~167 0~31(PEUa), 0~63(POUa), 0~167(POUc) None None None MP groupNone Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MPGRPN MP Group No. BSC6900 ADD IPLOGICPORT(Optional) MP group number None None Interval Type 0~167 0~167 None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MPGRPN MLPPP Group No. BSC6900 ADD BTSMPGRP(Mandatory)ADD BTSMPLNK(Mandatory) Number of an MLPPP group on a BTS. It is unique in a BTS. GBFD-118611Abis IP over E1/T1 Interval Type 0~3 0~3 None None None BTS None Read & Write Y PPP link Less than 5 minutes None
MPMODE Multiplexing Mode BSC6900 ADD BTS(Optional) Timeslot multiplexing mode at the Abis interface of the BTS. The BTS supports two multiplexing modes: statistical multiplexing on a 64 kbit/s timeslot and physical multiplexing on a 16 kbit/s timeslot. The first mode is further classified into the following six types: 1:1, 2:1, 3:1, 4:1, 5:1, and 6:1. A BTS supports the following six types of timeslot objects:OML: operation and maintenance link of the BTS. Each BTS has only one OML. In the case of statistical multiplexing on a 64 kbit/s timeslot, the OML works at 64 kbit/s. In this case, the OML can be multiplexed only with the signaling links in the same cabinet group of the BTS. In the case of physical multiplexing on a 16 kbit/s timeslot, the OML works at 16 kbit/s. In this case, the OML uses a 16 kbit/s timeslot.ESL: extended signaling link of the BTS. If the BTS supports Flex Abis, in the case of statistical multiplexing on a 64 kbit/s timeslot, a 64 kbit/s timeslot needs to be assigned to the ESL. In this case, the ESL is always multiplexed with the GBFD-111301LAPD Multiplexing at Abis Interface Enumeration Type MODE1_1, MODE2_1, MODE3_1, MODE4_1, MODE5_1, MODE6_1, MODE16K MODE1_1, MODE2_1, MODE3_1, MODE4_1, MODE5_1, MODE6_1, MODE16K None MODE4_1 MODE4_1 BTS This parameter can be set to MODE5_1 or MODE6_1 only when "FLEXABISMODE" is set to FLEX_ABIS. Read & Write Y BTS Less than 5 minutes None
MPN Connect Port No. BSC6900 SET BTSFMUABP(Optional)SET BTSAPMUBP(Optional)SET BTSDATUBP(Optional)SET BTSDEMUBP(Optional)SET BTSDHEUBP(Optional) Communication address of the CBUS3 on the bus 485. The configuration of this parameter must be consistent with the actual physical connection. Otherwise, the board may not work properly. GBFD-111202O&M of BTS Interval Type 0~1 0~1 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MPSWITCH MCPPP Switch BSC6900 ADD BTSMPGRP(Optional) MCPPP switchGBFD-118611Abis IP over E1/T1 Enumeration Type DISABLE(Disable), ENABLE(Enable) DISABLE, ENABLE None ENABLE ENABLE BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MPTYPE MP type BSC6900 ADD MPGRP(Optional) MP type GBFD-118611GBFD-118622 Abis IP over E1/T1A IP over E1/T1 Enumeration Type MLPPP, MCPPP MLPPP, MCPPP None MCPPP MCPPP MP groupNone Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MPUSLOT MPU Slot No. BSC6900 ADD BRD(Mandatory)SET MPUBIND(Mandatory) Number of the slot where the MPU is located MRFD-210301Configuration Management Interval Type 0~27 0~27 None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MPUSUBRACK MPU Subrack No. BSC6900 ADD BRD(Mandatory)SET MPUBIND(Mandatory) Number of the subrack where the MPU is located MRFD-210301Configuration Management Interval Type 0~11 0~11 None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MRCOMPREG MR. Compensation Allowed BSC6900 SET GCELLPWR2(Optional) Whether power control algorithm II allows measurement report compensation. When making a power control decision, the BSC retrieves a certain number of history measurement reports and performs weighted filtering on the receive level values and receive quality values in these reports, which may be obtained when different transmit powers were used by BTSs or MSs. To ensure that correct receive level values and receive quality values are used in filtering, you must compensate the receive level values and receive quality values in history measurement reports obtained when transmit powers different than the current one were used. GBFD-110703Enhanced Power Control Algorithm Enumeration Type NO(No), YES(Yes)NO, YES None None YES Cell This parameter is valid when "PWRCTRLSW" in the "SET GCELLPWRBASIC" command is set to PWR2. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MRMISSCOUNT Allowed MR Number Lost BSC6900 SET GCELLHOFITPEN(Optional) If the number of measurement reports lost consecutively is no larger than this value, linear interpolation is performed for the values in the lost measurement reports based on the values in the two measurement reports preceding and following the lost measurement reports. Otherwise, the lost measurement reports will be discarded, and the value will be recalculated when new measurement reports arrive. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 0~31 0~31 None None 4 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved Because the measurement reports may not always be correctly decoded when the quality of a serving cell is poor, handovers may fail when the number of the lost measurement reports exceeds the value set by this parameter. You can set a relatively larger value for this parameter, thus enabling emergency handovers.
MRMISSNUM MRMissNumber BSC6900 SET GCELLPWR3(Optional) When the number of the lost measurement reports exceeds this parameter during a power control period, the power control stops. GBFD-117601HUAWEI III Power Control Algorithm Interval Type 1~255 1~255 None None 5 Cell This parameter is valid only when "PWRCTRLSW" in "SET GCELLPWRBASIC" is set to PWR3. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MRPREPROCFREQ Sent Freq.of preprocessed MR BSC6900 SET GCELLHOCTRL(Optional) Frequency at which the BTSs submit pre-processed measurement reports to the BSC GBFD-110802Pre-processing of Measurement Report Enumeration Type NOreport(Do not report), Twice_ps(Twice every second), Once_ps(Once every second), Once_2s(Once every two second), Once_4s(Once every four second) NOreport, Twice_ps, Once_ps, Once_2s, Once_4s None None Twice_ps Cell This parameter must be set when "BTSMESRPTPREPROC" is set to BTS_PreprocessingN. Read & Write N (No impact on the UE in idle mode) Not involved Not involved When this parameter is set to Noreport, the BTSs do not submit measurement reports to the BSC, which disables handovers and power control, and greatly impacts on the speech quality.
MRRUATTENFACTOR1 Antenna Tributary 1 Factor BSC6900 SET BTSRXUBP(Optional) Attenuation factor for the TMA of antenna tributary 1 GBFD-111202O&M of BTS Interval Type 4~22 4~22 dB 4 None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MRRUATTENFACTOR2 Antenna Tributary 2 Factor BSC6900 SET BTSRXUBP(Optional) Attenuation factor for the TMA of antenna tributary 2 GBFD-111202O&M of BTS Interval Type 4~22 4~22 dB 4 None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MRSCOPESWITCH MR Collection Scope Switch BSC6900 SET GMRSCOPE(Mandatory) Switch of measurement report collection within a specified scope. If the specified scope is a site, the switch applies to all the cells at the site; if the specified scope is a cell, the switch applies to the cell only. The switch of measurement report collection within a specified scope last configured takes effect. GBFD-111203O&M of BSC Enumeration Type OFF(Off), ON(On) OFF, ON None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MRSWITCH MR Collection Control Switch BSC6900 SET GMRCTRL(Mandatory) The control switch of measurement report collection includes OFF (do not collect), ON_WITH_SDCCH (collect measurement reports for SDCCHs and TCHs), and ON_WITHOUT_SDCCH (collect measurement reports for TCHs only). GBFD-111203O&M of BSC Enumeration Type OFF(Off), ON_WITH_SDCCH(On with SDCCH), ON_WITHOUT_SDCCH(On without SDCCH) OFF, ON_WITH_SDCCH, ON_WITHOUT_SDCCH None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MRU Max Receive Unit BSC6900 ADD BTSPPPLNK(Optional)ADD BTSMPLNK(Optional) Negotiation parameter. This parameter determines the maximum length of a received packet. GBFD-118601Abis over IP Interval Type 128~1500 128~1500 None 1500 1500 BTS None Read & Write Y PPP link Less than 5 minutes None
MS Number of MSs BSC6900 ADD AISSCFG(Optional) Number of MSs used when the offset information is collected. GBFD-118201Soft-Synchronized Network Interval Type 1~16 1~16 None 3 None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None.
MSCAPABLESTATSWITCH MS Capability Statistic Switch BSC6900 SET GCELLSOFT(Optional) Whether to collect the information about the MSs of different capabilities in a cell. This parameter has no impact on services. GBFD-110501Call Control Enumeration Type OFF(Off), ON(On) OFF, ON None OFF OFF Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MSCCAP MSC Available Capability<K User number> BSC6900 ADD GCNNODE(Optional) Available capacity of the MSC GBFD-117401MSC Pool Interval Type 0~65535 0~65535 None 1800 1800 MSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MSCNRILEN Length of NRI in TMSI BSC6900 ADD GCNOPERATOR(Mandatory) Number of bits occupied by the NRI in the TMSI GBFD-117401MSC Pool Interval Type 1~10 1~10 None None 1 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MSCNULLNRI MSC NULL-NRI Value BSC6900 ADD GCNOPERATOR(Optional) Special NRI that is coded together with common NRIs. This parameter is used to indicate that the BSC routes the service initiated by the MS to the MSC in non OFFLOAD state. GBFD-117401MSC Pool Interval Type 0~1023 0~1023 None 0 0 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MSCPOOLALLOW MSC Pool Function Enabled BSC6900 ADD GCNOPERATOR(Optional) Whether to enable the MSC pool function on the BSC. The MSC pool function enables up to 32 MSCs to provide services for mobile subscribers in a BSC. With the MSC pool function, one BSC can be connected to multiple MSCs and the services in the BSC are shared to each MSC in all MSC pools. GBFD-117401MSC Pool Enumeration Type NO(No), YES(Yes)NO, YES None NO NO BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MSCSTATUE MSC Administrable State BSC6900 ADD GCNNODE(Optional) Administrative state of the MSC GBFD-117401MSC Pool Enumeration Type OFFLOAD(Offload), NORMAL(Normal), UNAVAIL(Unavailable) OFFLOAD, NORMAL, UNAVAIL None NORMAL NORMAL MSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved If the MSC pool function is enabled, and the value of this parameter is not NORMAL, the DPC is not selected for call access.
MSCVER MSC Version Indication BSC6900 SET GCELLCCUTRANSYS(Optional) Protocol version of the MSC that is connected to the BSC. The supported signaling varies with the protocol versions. GBFD-111804A Interface Protocol Process Enumeration Type R98_or_below(R98 or below), R99_or_above(R99 or above) R98_or_below, R99_or_above None R98_or_belowR98_or_below Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved If the GSM BSC is connected to the GSM MSC, it is recommended that you set this parameter to R98_or_below. If the GSM BSC is connected to the UMTS MSC, it is recommended that you set this parameter to R99_or_above.
MSIPFAILINDDELAY TREESTABLISH BSC6900 SET GCELLTMR(Optional) Call reestablishment timer GBFD-110503Call Reestablishment Interval Type 5000~40000 5000~40000 ms None 15000 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MSISDN MSISDN BSC6900 CHK INNSPCH(Mandatory)STR CALLRESLOP(Mandatory) MSISDN value GBFD-111203O&M of BSC String Type None 1~32 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MSISDNPREFIX1 MSISDN prefix 1 BSC6900 SET BSCBASIC(Optional) MSISDN prefix 1. When matching the call specified by the mobile number, the BSC adds the MSISDN prefix 1 according to the value of this parameter. GBFD-117701GBFD-117702 BSC Local SwitchBTS Local Switch String Type None 1~5 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MSISDNPREFIX2 MSISDN prefix 2 BSC6900 SET BSCBASIC(Optional) MSISDN prefix 2. When matching the call specified by the mobile number, the BSC adds the MSISDN prefix 2 according to the value of this parameter. GBFD-117701GBFD-117702 BSC Local SwitchBTS Local Switch String Type None 1~5 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MSISDNPREFIX3 MSISDN prefix 3 BSC6900 SET BSCBASIC(Optional) MSISDN prefix 3. When matching the call specified by the mobile number, the BSC adds the MSISDN prefix 3 according to the value of this parameter. GBFD-117701GBFD-117702 BSC Local SwitchBTS Local Switch String Type None 1~5 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MSISDNPREFIX4 MSISDN prefix 4 BSC6900 SET BSCBASIC(Optional) MSISDN prefix 4. When matching the call specified by the mobile number, the BSC adds the MSISDN prefix 4 according to the value of this parameter. GBFD-117701GBFD-117702 BSC Local SwitchBTS Local Switch String Type None 1~5 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MSISDNPREFIX5 MSISDN prefix 5 BSC6900 SET BSCBASIC(Optional) MSISDN prefix 5. When matching the call specified by the mobile number, the BSC adds the MSISDN prefix 5 according to the value of this parameter. GBFD-117701GBFD-117702 BSC Local SwitchBTS Local Switch String Type None 1~5 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MsisdnPrfxList2StartBscLs1 Prefix Number for BSC 1 BSC6900 SET BSSLS(Optional) If "Options for BSC Local Switch" is set to PREFIXNUMBER, and the first digits in the MSISDN of the called or calling are the same as the value of this parameter, the BSC local switching function is enabled. For example, if two numbers 135 and 139 are set in the list, and the first three digits in the MSISDN of the called or calling are 135 or 139, the BSC local switching function is enabled. GBFD-117701BSC Local Switch String Type None 1~32 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MsisdnPrfxList2StartBscLs10 Prefix Number for BSC 10 BSC6900 SET BSSLS(Optional) If "Options for BSC Local Switch" is set to PREFIXNUMBER, and the first digits in the MSISDN of the called or calling are the same as the value of this parameter, the BSC local switching function is enabled. For example, if two numbers 135 and 139 are set in the list, and the first three digits in the MSISDN of the called or calling are 135 or 139, the BSC local switching function is enabled. GBFD-117701BSC Local Switch String Type None 1~32 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MsisdnPrfxList2StartBscLs2 Prefix Number for BSC 2 BSC6900 SET BSSLS(Optional) If "Options for BSC Local Switch" is set to PREFIXNUMBER, and the first digits in the MSISDN of the called or calling are the same as the value of this parameter, the BSC local switching function is enabled. For example, if two numbers 135 and 139 are set in the list, and the first three digits in the MSISDN of the called or calling are 135 or 139, the BSC local switching function is enabled. GBFD-117701BSC Local Switch String Type None 1~32 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MsisdnPrfxList2StartBscLs3 Prefix Number for BSC 3 BSC6900 SET BSSLS(Optional) If "Options for BSC Local Switch" is set to PREFIXNUMBER, and the first digits in the MSISDN of the called or calling are the same as the value of this parameter, the BSC local switching function is enabled. For example, if two numbers 135 and 139 are set in the list, and the first three digits in the MSISDN of the called or calling are 135 or 139, the BSC local switching function is enabled. GBFD-117701BSC Local Switch String Type None 1~32 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MsisdnPrfxList2StartBscLs4 Prefix Number for BSC 4 BSC6900 SET BSSLS(Optional) If "Options for BSC Local Switch" is set to PREFIXNUMBER, and the first digits in the MSISDN of the called or calling are the same as the value of this parameter, the BSC local switching function is enabled. For example, if two numbers 135 and 139 are set in the list, and the first three digits in the MSISDN of the called or calling are 135 or 139, the BSC local switching function is enabled. GBFD-117701BSC Local Switch String Type None 1~32 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MsisdnPrfxList2StartBscLs5 Prefix Number for BSC 5 BSC6900 SET BSSLS(Optional) If "Options for BSC Local Switch" is set to PREFIXNUMBER, and the first digits in the MSISDN of the called or calling are the same as the value of this parameter, the BSC local switching function is enabled. For example, if two numbers 135 and 139 are set in the list, and the first three digits in the MSISDN of the called or calling are 135 or 139, the BSC local switching function is enabled. GBFD-117701BSC Local Switch String Type None 1~32 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MsisdnPrfxList2StartBscLs6 Prefix Number for BSC 6 BSC6900 SET BSSLS(Optional) If "Options for BSC Local Switch" is set to PREFIXNUMBER, and the first digits in the MSISDN of the called or calling are the same as the value of this parameter, the BSC local switching function is enabled. For example, if two numbers 135 and 139 are set in the list, and the first three digits in the MSISDN of the called or calling are 135 or 139, the BSC local switching function is enabled. GBFD-117701BSC Local Switch String Type None 1~32 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MsisdnPrfxList2StartBscLs7 Prefix Number for BSC 7 BSC6900 SET BSSLS(Optional) If "Options for BSC Local Switch" is set to PREFIXNUMBER, and the first digits in the MSISDN of the called or calling are the same as the value of this parameter, the BSC local switching function is enabled. For example, if two numbers 135 and 139 are set in the list, and the first three digits in the MSISDN of the called or calling are 135 or 139, the BSC local switching function is enabled. GBFD-117701BSC Local Switch String Type None 1~32 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MsisdnPrfxList2StartBscLs8 Prefix Number for BSC 8 BSC6900 SET BSSLS(Optional) If "Options for BSC Local Switch" is set to PREFIXNUMBER, and the first digits in the MSISDN of the called or calling are the same as the value of this parameter, the BSC local switching function is enabled. For example, if two numbers 135 and 139 are set in the list, and the first three digits in the MSISDN of the called or calling are 135 or 139, the BSC local switching function is enabled. GBFD-117701BSC Local Switch String Type None 1~32 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MsisdnPrfxList2StartBscLs9 Prefix Number for BSC 9 BSC6900 SET BSSLS(Optional) If "Options for BSC Local Switch" is set to PREFIXNUMBER, and the first digits in the MSISDN of the called or calling are the same as the value of this parameter, the BSC local switching function is enabled. For example, if two numbers 135 and 139 are set in the list, and the first three digits in the MSISDN of the called or calling are 135 or 139, the BSC local switching function is enabled. GBFD-117701BSC Local Switch String Type None 1~32 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MsisdnPrfxList2StartBtsLs1 Prefix Number for BTS 1 BSC6900 SET BSSLS(Optional) If "Options for BSC Local Switch" is set to PREFIXNUMBER, and the first digits in the MSISDN of the called or calling are the same as the value of this parameter, the BSC local switching function is enabled. For example, if two numbers 135 and 139 are set in the list, and the first three digits in the MSISDN of the called or calling are 135 or 139, the BSC local switching function is enabled. GBFD-117702BTS Local Switch String Type None 1~32 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MsisdnPrfxList2StartBtsLs10 Prefix Number for BTS 10 BSC6900 SET BSSLS(Optional) If "Options for BSC Local Switch" is set to PREFIXNUMBER, and the first digits in the MSISDN of the called or calling are the same as the value of this parameter, the BSC local switching function is enabled. For example, if two numbers 135 and 139 are set in the list, and the first three digits in the MSISDN of the called or calling are 135 or 139, the BSC local switching function is enabled. GBFD-117702BTS Local Switch String Type None 1~32 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MsisdnPrfxList2StartBtsLs2 Prefix Number for BTS 2 BSC6900 SET BSSLS(Optional) If "Options for BSC Local Switch" is set to PREFIXNUMBER, and the first digits in the MSISDN of the called or calling are the same as the value of this parameter, the BSC local switching function is enabled. For example, if two numbers 135 and 139 are set in the list, and the first three digits in the MSISDN of the called or calling are 135 or 139, the BSC local switching function is enabled. GBFD-117702BTS Local Switch String Type None 1~32 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MsisdnPrfxList2StartBtsLs3 Prefix Number for BTS 3 BSC6900 SET BSSLS(Optional) If "Options for BSC Local Switch" is set to PREFIXNUMBER, and the first digits in the MSISDN of the called or calling are the same as the value of this parameter, the BSC local switching function is enabled. For example, if two numbers 135 and 139 are set in the list, and the first three digits in the MSISDN of the called or calling are 135 or 139, the BSC local switching function is enabled. GBFD-117702BTS Local Switch String Type None 1~32 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MsisdnPrfxList2StartBtsLs4 Prefix Number for BTS 4 BSC6900 SET BSSLS(Optional) If "Options for BSC Local Switch" is set to PREFIXNUMBER, and the first digits in the MSISDN of the called or calling are the same as the value of this parameter, the BSC local switching function is enabled. For example, if two numbers 135 and 139 are set in the list, and the first three digits in the MSISDN of the called or calling are 135 or 139, the BSC local switching function is enabled. GBFD-117702BTS Local Switch String Type None 1~32 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MsisdnPrfxList2StartBtsLs5 Prefix Number for BTS 5 BSC6900 SET BSSLS(Optional) If "Options for BSC Local Switch" is set to PREFIXNUMBER, and the first digits in the MSISDN of the called or calling are the same as the value of this parameter, the BSC local switching function is enabled. For example, if two numbers 135 and 139 are set in the list, and the first three digits in the MSISDN of the called or calling are 135 or 139, the BSC local switching function is enabled. GBFD-117702BTS Local Switch String Type None 1~32 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MsisdnPrfxList2StartBtsLs6 Prefix Number for BTS 6 BSC6900 SET BSSLS(Optional) If "Options for BSC Local Switch" is set to PREFIXNUMBER, and the first digits in the MSISDN of the called or calling are the same as the value of this parameter, the BSC local switching function is enabled. For example, if two numbers 135 and 139 are set in the list, and the first three digits in the MSISDN of the called or calling are 135 or 139, the BSC local switching function is enabled. GBFD-117702BTS Local Switch String Type None 1~32 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MsisdnPrfxList2StartBtsLs7 Prefix Number for BTS 7 BSC6900 SET BSSLS(Optional) If "Options for BSC Local Switch" is set to PREFIXNUMBER, and the first digits in the MSISDN of the called or calling are the same as the value of this parameter, the BSC local switching function is enabled. For example, if two numbers 135 and 139 are set in the list, and the first three digits in the MSISDN of the called or calling are 135 or 139, the BSC local switching function is enabled. GBFD-117702BTS Local Switch String Type None 1~32 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MsisdnPrfxList2StartBtsLs8 Prefix Number for BTS 8 BSC6900 SET BSSLS(Optional) If "Options for BSC Local Switch" is set to PREFIXNUMBER, and the first digits in the MSISDN of the called or calling are the same as the value of this parameter, the BSC local switching function is enabled. For example, if two numbers 135 and 139 are set in the list, and the first three digits in the MSISDN of the called or calling are 135 or 139, the BSC local switching function is enabled. GBFD-117702BTS Local Switch String Type None 1~32 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MsisdnPrfxList2StartBtsLs9 Prefix Number for BTS 9 BSC6900 SET BSSLS(Optional) If "Options for BSC Local Switch" is set to PREFIXNUMBER, and the first digits in the MSISDN of the called or calling are the same as the value of this parameter, the BSC local switching function is enabled. For example, if two numbers 135 and 139 are set in the list, and the first three digits in the MSISDN of the called or calling are 135 or 139, the BSC local switching function is enabled. GBFD-117702BTS Local Switch String Type None 1~32 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MsisdnSegList2AvoidBscLs1 Avoid Number for BSC 1 BSC6900 SET BSSLS(Optional) If the first digits in the MSISDN of the called or calling are the same as the value of this parameter, the BSC local switching function is disabled. GBFD-117701BSC Local Switch String Type None 1~32 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MsisdnSegList2AvoidBscLs10 Avoid Number for BSC 10 BSC6900 SET BSSLS(Optional) If the first digits in the MSISDN of the called or calling are the same as the value of this parameter, the BSC local switching function is disabled. GBFD-117701BSC Local Switch String Type None 1~32 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MsisdnSegList2AvoidBscLs2 Avoid Number for BSC 2 BSC6900 SET BSSLS(Optional) If the first digits in the MSISDN of the called or calling are the same as the value of this parameter, the BSC local switching function is disabled. GBFD-117701BSC Local Switch String Type None 1~32 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MsisdnSegList2AvoidBscLs3 Avoid Number for BSC 3 BSC6900 SET BSSLS(Optional) If the first digits in the MSISDN of the called or calling are the same as the value of this parameter, the BSC local switching function is disabled. GBFD-117701BSC Local Switch String Type None 1~32 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MsisdnSegList2AvoidBscLs4 Avoid Number for BSC 4 BSC6900 SET BSSLS(Optional) If the first digits in the MSISDN of the called or calling are the same as the value of this parameter, the BSC local switching function is disabled. GBFD-117701BSC Local Switch String Type None 1~32 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MsisdnSegList2AvoidBscLs5 Avoid Number for BSC 5 BSC6900 SET BSSLS(Optional) If the first digits in the MSISDN of the called or calling are the same as the value of this parameter, the BSC local switching function is disabled. GBFD-117701BSC Local Switch String Type None 1~32 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MsisdnSegList2AvoidBscLs6 Avoid Number for BSC 6 BSC6900 SET BSSLS(Optional) If the first digits in the MSISDN of the called or calling are the same as the value of this parameter, the BSC local switching function is disabled. GBFD-117701BSC Local Switch String Type None 1~32 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MsisdnSegList2AvoidBscLs7 Avoid Number for BSC 7 BSC6900 SET BSSLS(Optional) If the first digits in the MSISDN of the called or calling are the same as the value of this parameter, the BSC local switching function is disabled. GBFD-117701BSC Local Switch String Type None 1~32 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MsisdnSegList2AvoidBscLs8 Avoid Number for BSC 8 BSC6900 SET BSSLS(Optional) If the first digits in the MSISDN of the called or calling are the same as the value of this parameter, the BSC local switching function is disabled. GBFD-117701BSC Local Switch String Type None 1~32 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MsisdnSegList2AvoidBscLs9 Avoid Number for BSC 9 BSC6900 SET BSSLS(Optional) If the first digits in the MSISDN of the called or calling are the same as the value of this parameter, the BSC local switching function is disabled. GBFD-117701BSC Local Switch String Type None 1~32 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MsisdnSegList2AvoidBtsLs1 Avoid Number for BTS 1 BSC6900 SET BSSLS(Optional) If the first digits in the MSISDN of the called or calling are the same as the value of this parameter, the BTS local switching function is disabled. GBFD-117702BTS Local Switch String Type None 1~32 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MsisdnSegList2AvoidBtsLs10 Avoid Number for BTS 10 BSC6900 SET BSSLS(Optional) If the first digits in the MSISDN of the called or calling are the same as the value of this parameter, the BTS local switching function is disabled. GBFD-117702BTS Local Switch String Type None 1~32 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MsisdnSegList2AvoidBtsLs2 Avoid Number for BTS 2 BSC6900 SET BSSLS(Optional) If the first digits in the MSISDN of the called or calling are the same as the value of this parameter, the BTS local switching function is disabled. GBFD-117702BTS Local Switch String Type None 1~32 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MsisdnSegList2AvoidBtsLs3 Avoid Number for BTS 3 BSC6900 SET BSSLS(Optional) If the first digits in the MSISDN of the called or calling are the same as the value of this parameter, the BTS local switching function is disabled. GBFD-117702BTS Local Switch String Type None 1~32 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MsisdnSegList2AvoidBtsLs4 Avoid Number for BTS 4 BSC6900 SET BSSLS(Optional) If the first digits in the MSISDN of the called or calling are the same as the value of this parameter, the BTS local switching function is disabled. GBFD-117702BTS Local Switch String Type None 1~32 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MsisdnSegList2AvoidBtsLs5 Avoid Number for BTS 5 BSC6900 SET BSSLS(Optional) If the first digits in the MSISDN of the called or calling are the same as the value of this parameter, the BTS local switching function is disabled. GBFD-117702BTS Local Switch String Type None 1~32 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MsisdnSegList2AvoidBtsLs6 Avoid Number for BTS 6 BSC6900 SET BSSLS(Optional) If the first digits in the MSISDN of the called or calling are the same as the value of this parameter, the BTS local switching function is disabled. GBFD-117702BTS Local Switch String Type None 1~32 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MsisdnSegList2AvoidBtsLs7 Avoid Number for BTS 7 BSC6900 SET BSSLS(Optional) If the first digits in the MSISDN of the called or calling are the same as the value of this parameter, the BTS local switching function is disabled. GBFD-117702BTS Local Switch String Type None 1~32 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MsisdnSegList2AvoidBtsLs8 Avoid Number for BTS 8 BSC6900 SET BSSLS(Optional) If the first digits in the MSISDN of the called or calling are the same as the value of this parameter, the BTS local switching function is disabled. GBFD-117702BTS Local Switch String Type None 1~32 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MsisdnSegList2AvoidBtsLs9 Avoid Number for BTS 9 BSC6900 SET BSSLS(Optional) If the first digits in the MSISDN of the called or calling are the same as the value of this parameter, the BTS local switching function is disabled. GBFD-117702BTS Local Switch String Type None 1~32 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MSLEVSTRQPBGT EN Quick PBGT HO ALG When MS Leaves BTS BSC6900 SET GCELLHOFAST(Optional) Whether to enable "Triggering the quick PBGT algorithm only when an MS is far from the BTS" GBFD-510102Fast Move Handover Enumeration Type NO(No), YES(Yes)NO, YES None None NO Cell This parameter is valid only when "QUICKHOEN" in "SET GCELLHOBASIC" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MSMAXRETRAN MS MAX Retrans BSC6900 SET GCELLCCBASIC(Optional) Maximum number of Channel Request messages that can be sent by an MS in an immediate assignment procedure. After the MS initiates the immediate assignment procedure, it always listens to the messages on the BCCH and all the common control channels (CCCHs) in the CCCH group to which the MS belongs. If the MS does not receive Immediate Assignment or Immediate Assignment Extend messages, it retransmits Channel Request messages at a specified interval. If the downlink quality is poor, the MS may send SABM frames to the BTS multiple times. GBFD-111003Radio Common Channel Management Enumeration Type 1_Times(1_Times), 2_Times(2_Times), 4_Times(4_Times), 7_Times(7_Times) 1_Times, 2_Times, 4_Times, 7_Times None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MSPCMD MSP Control Command BSC6900 SET MSPCMD(Mandatory) Control command of the MSP switchover protection group None None Enumeration Type CLEAR(Cleared), LOP(Lockout of Protection), FS(Forcibly switchover working link to protection link), MS(Manual switchover from working link to protection link), EXERS(Exercisely switch working link to protection link) CLEAR, LOP, FS, MS, EXERS, None None None MSP protect group None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
MSRDMCSLEV MSRD MCS Threshold BSC6900 SET GCELLPSCHM(Optional) Threshold of the MS Receiver Diversity (MSRD) mode. GBFD-510801MSRD Enumeration Type MCS1(MCS1), MCS2(MCS2), MCS3(MCS3), MCS4(MCS4), MCS5(MCS5), MCS6(MCS6), MCS7(MCS7), MCS8(MCS8), MCS9(MCS9) MCS1, MCS2, MCS3, MCS4, MCS5, MCS6, MCS7, MCS8, MCS9 None None MCS5 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MSRDPDCHLEV MSRD PDCH Multiplex Threshold BSC6900 SET GCELLPSCHM(Optional) PDCH Downlink multiplex threshold in the Mobile Station Receiver Diversity (MSRD) mode. When this parameter is set to "80", the MS does not adopt the MSRD mode. When the number of the TBF on the PDCH that is assigned to the MS exceeds this parameter or the coding rate of the PDCH is smaller than the threshold of the coding rate in MSRD mode, the MS is required to adopt the MSRD mode. GBFD-510801MSRD Interval Type 10~80 10~80 None None 40 Cell The value of this parameter must be smaller than or equal to "PDCH Downlink Multiplex Threshold". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MSRN Subrack No. of Management Board BSC6900 SET BTSFMUABP(Optional)SET BTSAPMUBP(Optional)SET BTSDATUBP(Optional)SET BTSDEMUBP(Optional)SET BTSDHEUBP(Optional) Number of the subrack where the board is located. The management board refers to the TMU or RXU that directly communicates with the board. The configuration of this parameter must be consistent with the actual physical connection. Otherwise, the board may not work properly. GBFD-111202O&M of BTS Interval Type 0~254 0~254 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MSRXMIN Min DL level on candidate Cell BSC6900 ADD GEXT2GCELL(Optional) The M criteria supports setting minimum values for the downlink receive level of neighboring cells. The M criteria is met only when ,Estimated downlink level of neighboring cells >= ("Min DL level on candidate Cell" + "Min Access Level Offset")Estimated uplink level of neighboring cells >= ("Min UL level on candidate Cell" + "Min Access Level Offset") GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 0~63 0~63 dB None 10 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MSRXQUALSTATTHRSH MS Rx Quality Statistic Threshold BSC6900 SET GCELLNC2PARA(Optional) When the number of received measurement reports on the downlink transmission quality exceeds this threshold, the system determines whether to start emergency reselection. GBFD-116201Network-Controlled Cell Reselection (NC2) Interval Type 0~255 0~255 None None 200 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MSTF MS Flow Control Timer BSC6900 SET BSSGPPARA(Optional) Duration of the flow control timer F of the MS. The MS sends the flow control message according to this duration. GBFD-119001Gb Interface Function Interval Type 1000~3000 1000~3000 ms None 1000 BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MSTSERVACTDELAY Master Service Active Delay BSC6900 SET GBSCREDGRP(Optional) If no handshake message is received from the peer within the delay, the master service is activated. GBFD-113725BSC Node Redundancy Interval Type 1~600 1~600 s 45 None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MSTXPWRMAX Maximum TX Power for Access PCH BSC6900 SET GCELLSERVPARA(Optional) Maximum TX power for the MS to access the PCH. GBFD-114101GPRS Interval Type 0~31 0~31 None None 2 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MTCACCESSCPURATE MTC Access CPU Rate BSC6900 SET BSCFCPARA(Optional) Usage threshold of the CPU for called access. If the usage of the CPU exceeds the threshold, the called access request is transferred to other CPU for processing. GBFD-111705GSM Flow Control Interval Type 50~95 50~95 per cent None 85 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MTHD Method BSC6900 CHK E1T1CRS(Mandatory) Detection method None None Enumeration Type ALARM_METHOD(Alarm method), LOOP_METHOD(Loop method) ALARM_METHOD, LOOP_METHOD None None None E1/T1 port None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
MTP2LNKN MTP2 link No. BSC6900 ADD MTP3LNK(Mandatory) To identify an MTP2 link. None None Interval Type 0~63 0~63 None None None MTP3 linkNone Read & Write Not involved Not involved Not involved The parameter cannot be modified.
MTU MTU value BSC6900 ADD SCTPLNK(Optional) Maximum transport unit. None None Interval Type 500~1500 500~1500 None 800 800 SCTP linkNone Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MTU MTU[Byte] BSC6900 ADD DEVIP(Optional) Maximum transmission unit None None Interval Type 776~1696 776~1696 byte 1696 1696 BSC6900None Read & Write Y BSC6900 If the MTU configuration fails to meet the requirement of the network, the services will be adversely affected. The interconnection may be affected if this parameter is modified.
MTU MTU[Byte] BSC6900 SET ETHPORT(Optional) Maximum transmission unit None None Interval Type 256~1650 256~1650 byte None 1500 Ethernet port None Read & Write Y BSC6900 If the mode is not consistent, will interrupt service until it is consistent. The interconnection may be affected if this parameter is modified.
MTU MTU BSC6900 SET BTSETHPORT(Optional) Maximum number of bytes allowed for a packet transmitted or received on the FE port GBFD-118611Abis IP over E1/T1 Interval Type 0~1500 0~1500 None None If "MTU" is set to a value smaller than 576, the DHCP procedure may fail when the BTS tries to retrieve the IP address, and thus the BTS cannot work. The recommended value of this parameter is 1500. Do not modify it unless in special scenarios, for example, at the bottom layer where the number of MTU is limited. BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MTVT Hierarchical Power Supply Para.<0.1v> BSC6900 SET BTSBAT(Optional) Bus voltage of the battery rack of the BTS GBFD-111202O&M of BTS Interval Type 190~240 19.0~24.0, step:0.1 V None 225 BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter is supported only by the BTS3012A and BTS3006A.
MULTIBANDREP Multi-Band Report BSC6900 SET GCELLSERVPARA(Optional) Multi-band point report value, including "report six cells with the strongest signal at each frequency point", "report one cell with the strongest signal at each frequency point","report two cells with the strongest signal at each frequency point", and "report three cells with the strongest signal at each frequency point". GBFD-114101GPRS Enumeration Type REPORT6(Report six), REPORT1(Report one), REPORT2(Report two), REPORT3(Report three) REPORT6, REPORT1, REPORT2, REPORT3 None None REPORT6 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
Mute_Detect Mute Detect BSC6900 SET TCPARA(Optional) The user sets the function of one-way audio check on the BSC. If the function is enabled, the BSC notifies the DPU to perform one-way audio check when a call is established. GBFD-111203O&M of BSC Enumeration Type CLOSE(Close), OPEN(Open) CLOSE, OPEN None None CLOSE Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
Mute_Timer Mute Timer BSC6900 SET TCPARA(Optional) This parameter indicates the duration of the one-way audio check. GBFD-111203O&M of BSC Interval Type 0~255 0~255 s None 5 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MUTEFORBITCALLTMINTVAL Access Prohibited Upon One-Way Audio BSC6900 SET GCELLSOFT(Optional) Time for prohibiting the call from accessing the corresponding channel where one-way audio is detected on the Abis interface. GBFD-116401End-to-End MS Signaling Tracing Interval Type 0~15 {0~15} min None 0 Cell None Read & Write Not involved Not involved Not involved If the value of this parameter is increased, the cell congestion rate increases. If the value of this parameter is decreased, one-way audio may persist after the handover.
MUTERELCALLEN Forced Call Release Upon Failed Handover in One-Way Audio BSC6900 SET GCELLSOFT(Optional) Whether to forcibly release a call after the forced handover fails in the case of one-way audio on the Abis interface. GBFD-116401End-to-End MS Signaling Tracing Enumeration Type NO(No), YES(Yes)NO, YES None None NO Cell None Read & Write Not involved Not involved Not involved If this parameter is set to YES, the call drop rate may increase.
MUXTIME PPP mux framing out-time[us] BSC6900 ADD PPPLNK(Optional) Maximum waiting duration when the MUX operation is performed for the sub-frame over the PPPMUX link GBFD-118611GBFD-118622 Abis IP over E1/T1A IP over E1/T1 Interval Type 1~1500 1~1500 ls 1000 1000 PPP link None Read & Write Y PPP link Interrupt the service until negotiate successfully again. Negotiation can succeed only when the configuration is consistent on the local and peer ends.
5/5/2014
Confidential Information of Huawei.
No Spreading without Permission
Page13of42
226347869.xls.ms_office Security Level:
MUXTIME PPP mux framing out-time[us] BSC6900 ADD MPGRP(Optional) Maximum waiting duration when the MUX operation is performed for the sub-frame over the PPPMUX link GBFD-118611GBFD-118622 Abis IP over E1/T1A IP over E1/T1 Interval Type 1~1500 1~1500 ls None 1000 MP groupNone Read & Write N (No impact on the UE in idle mode) Not involved Not involved Negotiation can succeed only when the configuration is consistent on the local and peer ends.
MUXTYPE IP MUX Type BSC6900 ADD IPMUX(Mandatory) IP packet multiplexing type GBFD-118604GBFD-118610 Abis MUXUDP MUX for A Transmission Enumeration Type FPMUX, UDPMUX, ABISMUX, ATERMUX FPMUX, UDPMUX, ABISMUX, ATERMUX None None None IP path None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The adjacent node ID must be configured.
MWTRXNO Min quantity of working TRXs BSC6900 SET BTSCABPARA(Optional) Minimum number of reserved working status TRXs of the cabinet GBFD-111202O&M of BTS Interval Type 0~12 0~12 None None 6 BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
MYDISCRIMINATOR My discriminator of BFD BSC6900 STR IPCHK(Optional) BFD local description mark GBFD-118609IP Fault Detection Based on BFD Interval Type 1~512 1~16(FG2a/GOUa), 1~512(FG2c/GOUc) None None None None None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
N200 N200 BSC6900 SET BTSRINGATTR(Optional) System parameter in the LAPD protocol. The value of this parameter specifies the maximum number of times when a frame is retransmitted. GBFD-117801Ring Topology Interval Type 1~3 1~3 None None When the transmission quality is good, the recommended settings are as follows: "Ring II Wait Time Before Switch" = 0; "Ring II Try Rotating Duration Time" = 60; "Ring II Rotating Penalty Time" = 0; "T200(10ms)" = 12; "T203(s)" = 1; and "N200" = 3.When the transmission quality is bad, the recommended settings are as follows: "Ring II Wait Time Before Switch" = 30; "Ring II Try Rotating Duration Time" = 60; "Ring II Rotating Penalty Time" = 0; "T200(10ms)" = 24; "T203(s)" = 3; and "N200" = 3. BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
N200ESTAB N200 of Establish BSC6900 SET GCELLCCTMR(Optional) Error control is performed on the I frame sent over the LAPDm layer between the BTS and MS. If the MS detects errors in an I frame, the BTS should resend the I frame. This parameter indicates the maximum number of retransmissions of the I frame.For the function of N200 and the effect of the parameter, see the description of "T200 SDCCH". GBFD-111002Radio Link Management Interval Type 5~254 5~254 None None None Cell N200ESTAB must be set when "N200PARASWITCH" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
N200FFULL N200 of FACCH/Full Rate BSC6900 SET GCELLCCTMR(Optional) Error control is performed on the I frame sent over the LAPDm layer between the BTS and MS. If the MS detects errors in an I frame, the BTS should resend the I frame. This parameter indicates the maximum number of retransmissions of the I frame on the FACCH (a full-rate channel).For the function of N200 and the effect of the parameter, see the description of "T200 SDCCH". GBFD-111002Radio Link Management Interval Type 34~254 34~254 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
N200FHALF N200 of FACCH/Half Rate BSC6900 SET GCELLCCTMR(Optional) Error control is performed on the I frame sent over the LAPDm layer between the BTS and MS. If the MS detects errors in an I frame, the BTS should resend the I frame. This parameter indicates the maximum number of retransmissions of the I frame on the FACCH (a half-rate channel).For the function of N200 and the effect of the parameter, see the description of "T200 SDCCH". GBFD-111002Radio Link Management Interval Type 29~254 29~254 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
N200PARASWITCH Use LAPDm N200 BSC6900 SET GCELLCCTMR(Optional) Whether the BSC sends the LAPDm N200 parameter to the BTS. If this parameter is set to YES, the BSC sends the LAPDm N200 parameter. If this parameter is set to NO, the BSC does not send the LAPDm N200 parameter. GBFD-111002Radio Link Management Enumeration Type OFF(Off), ON(On) OFF, ON None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
N200REL N200 of Release BSC6900 SET GCELLCCTMR(Optional) Error control is performed on the I frame sent over the LAPDm layer between the BTS and MS. If the MS detects errors in an I frame, the BTS should resend the I frame. This parameter indicates the maximum number of retransmissions of the I frame during the multi-frame release.For the function of N200 and the effect of the parameter, see the description of "T200 SDCCH". GBFD-111002Radio Link Management Interval Type 5~254 5~254 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
N200SACCH N200 of SACCH BSC6900 SET GCELLCCTMR(Optional) Error control is performed on the I frame sent over the LAPDm layer between the BTS and MS. If the MS detects errors in an I frame, the BTS should resend the I frame. This parameter indicates the maximum number of retransmissions of the I frame on the SACCH.For the function of N200 and the effect of the parameter, see the description of "T200 SDCCH". GBFD-111002Radio Link Management Interval Type 5~254 5~254 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
N200SDCCH N200 of SDCCH BSC6900 SET GCELLCCTMR(Optional) Error control is performed on the I frame sent over the LAPDm layer between the BTS and MS. If the MS detects errors in an I frame, the BTS should resend the I frame. This parameter indicates the maximum number of retransmissions of the I frame on the SDCCH.For the function of N200 and the effect of the parameter, see the description of "T200 SDCCH". GBFD-111002Radio Link Management Interval Type 23~254 23~254 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
N3101 Maximum Value of N3101 BSC6900 SET GCELLSTANDARDOPTPARA(Optional) Maximum value of the N3101 counter. In the dynamic uplink allocation mode, the network side enables multiple MSs to share the same uplink channel through the USF value in the downlink data block. After the network side allocates the USF to the uplink TBF (the uplink TBF is set up successfully), N3101 is started. The network side waits for the RLC uplink data block sent by the MS. If the RLC uplink data block sent by the MS is valid, N3101 is reset. Otherwise, the value of N3101 is increased on the network side. When this counter is overflowed, the current uplink TBF is released abnormally. GBFD-114101GPRS Interval Type 8~30 8~30 None None 20 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
N3103 Maximum Value of N3103 BSC6900 SET GCELLSTANDARDOPTPARA(Optional) Maximum value of the N3101 counter. When the uplink transmission ends, if the network side receives the last RLC data block, the network side sends an FAI=1 uplink packet acknowledged/unacknowledged message and starts N3103. If the packet control acknowledgement message is not received in the specified time, N3103 is increased on the network side and the uplink packet acknowledged/unacknowledged message is retransmitted. When this counter is overflowed, the timer T3169 is started. After this timer expires, the current TBF is released abnormally. GBFD-114101GPRS Interval Type 2~5 2~5 None None 3 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
N3105 Maximum Value of N3105 BSC6900 SET GCELLSTANDARDOPTPARA(Optional) Maximum value of the N3105 counter. After the downlink TBF is set up successfully, the N3105 is started on the network side. After the downlink RLC data block is added with the RRBP domain on the network side, the valid packet acknowledged message responded by the MS is received in the uplink RLC data block in the RRBP domain. In this case, N3105 is reset. Otherwise, the value of N3105 is increased and the downlink data block of the RRBP is retransmitted. When N3105 is overflowed, T3195 is started. After the timer T3195 expires, the current TBF is released abnormally. GBFD-114101GPRS Interval Type 3~10 3~10 None None 10 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
N391 Parameter of DTE [N391] BSC6900 ADD BC(Optional) Counter on the DTE side. After link integrity is verified according to DTE parameter (N391), the global state query request is originated on the DTE side. GBFD-510002Gb Over FR Interval Type 1~255 1~255 None 6 6 BC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
N392 Parameter of DTE [N392] BSC6900 ADD BC(Optional) Counter on the DTE side, recording the checking times (DTE parameter N393). After link integrity is verified according to DTE parameter (N392), the state is restored. That is: if a fault occurs on the DTE side, and the system is found normal in the checking times (DTE parameter N392) out of the checking times (DTE parameter N393), the system is switched to the normal state. If the system operates normally on the DTE side, and the system is found faulty in the checking times (DTE parameter N392) out of the checking times (DTE parameter N393), the system is switched to the faulty state. N392 must be smaller than N393. GBFD-510002Gb Over FR Interval Type 1~10 1~10 None 3 3 BC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
N393 Parameter of DTE [N393] BSC6900 ADD BC(Optional) Counter on the DTE side, recording the checking times (DTE parameter N393). After link integrity is verified according to DTE parameter (N392), the state is restored. That is: if a fault occurs on the DTE side, and the system is found normal in the checking times (DTE parameter N392) out of the checking times (DTE parameter N393), the system is switched to the normal state. If the system operates normally on the DTE side, and the system is found faulty in the checking times (DTE parameter N392) out of the checking times (DTE parameter N393), the system is switched to the faulty state. N393 must be greater than N392. GBFD-510002Gb Over FR Interval Type 1~10 1~10 None 4 4 BC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NACCSPT Support NACC BSC6900 SET GCELLGPRS(Optional) Whether to support the network assisted cell change (NACC). The NACC is used in the network control modes NC0, NC1 or NC2. The NACC enables the network to notify the MS of the system information of the neighboring cell when the MS is in the packet transmission state. In this way, the MS can reselect a cell in a shorter time. GBFD-116301Network Assisted Cell Change (NACC) Enumeration Type NO(No), YES(Yes)NO, YES None None None Cell This parameter is valid only when "GPRS" is set to SupportAsInnPcu or SupportAsExtPcu. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NAME OSP name BSC6900 ADD OPC(Mandatory) OSP name. None None String Type None 1~49 characters None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NAME DSP name BSC6900 ADD N7DPC(Mandatory) DSP name. None None String Type None 1~49 characters None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NAME Signalling Route name BSC6900 ADD MTP3RT(Mandatory) One MTP3 route name. None None String Type None 1~31 characters None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NAME Signalling link set name BSC6900 ADD MTP3LKS(Mandatory) Signaling link set name. None None String Type None 1~31 characters None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NAME Signalling link name BSC6900 ADD MTP3LNK(Mandatory) One MTP3 link name. None None String Type None 1~31 characters None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NAME Adjacent Node Name BSC6900 ADD ADJNODE(Mandatory) Adjacent node name None None String Type None 1~31 characters None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NAME Local entity name BSC6900 ADD M3LE(Mandatory) Local entity name. The local entity name must be unique. None None String Type None 1~49 characters None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NAME Destination entity name BSC6900 ADD M3DE(Mandatory) Destination entity name. None None String Type None 1~49 characters None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NAME M3UA route name BSC6900 ADD M3RT(Mandatory) The M3UA route names and the M3UA routes are in the one-to-one matching relation. None None String Type None 1~31 characters None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NAME M3UA Signalling link set name BSC6900 ADD M3LKS(Mandatory) M3UA link set name. The names of the M3UA signaling link sets must be unique. None None String Type None 1~49 characters None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NAME M3UA Signaling link name BSC6900 ADD M3LNK(Mandatory) M3UA signaling link name. The M3UA link names and the M3UA links are in the one-to-one matching relation. None None String Type None 1~31 characters None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
Name BSC name BSC6900 SET BSCBASIC(Optional) name of the BSC GBFD-111203O&M of BSC String Type None 1~64 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NAME PCU Name BSC6900 ADD PCU(Mandatory) Name of the PCU. GBFD-114101GPRS String Type None 1~50 characters None None None BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NAMRLFRMTRXALLOWED Assign Non-AMR User Loose Fre. Reuse TRX BSC6900 SET GCELLCHMGAD(Optional) Whether to preferentially allocate loose multiplexing frequencies to non-AMR users GBFD-111005Enhanced Channel Assignment Algorithm Enumeration Type NO(No), YES(Yes)NO, YES None None NO Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NAVGI N_AVG_I BSC6900 SET GCELLPSPWPARA(Optional) Filter consistent of the collision signal strength of power control. When sampling must be performed (NAVGI) times before the MS obtains the efficient measurement signal. GBFD-119115Power Control Interval Type 0~15 0~15 None None 2 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NBAMRTFOSWITCH TFO Switch BSC6900 SET GCELLBASICPARA(Optional) Whether to enable the TFO function on the BTS through a CHANNEL ACTIVATION or MODE MODIFY message. GBFD-115501GBFD-115502GBFD-115701 AMR FRAMR HRTFO Enumeration Type DISABLE(Disable), ENABLE(Enable) DISABLE, ENABLE None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NBAPSRVPN NBAP service listening port No. BSC6900 SET SCTPSRVPORT(Optional) Number of the NBAP service listening port None None Interval Type 1024~65535 1024~65535 None None 58080 SCTP linkNone Read & Write Y SCTP link The services are interrupted until the SCTP link is working normally. The parameter modification should be negotiated with the peer end, and the BSC should be reset after the modification. It is recommended that this parameter should not be modified when the system is running.
NBR2GNCELL1ID Neighbor 2G Cell 1 Index BSC6900 ADD GIBCAPNCGRP(Mandatory) Uniform number of neighboring cell 1 index within a BSC, which uniquely identifies a cell and is in the range 0 to 5047. MRFD-210301Configuration Management Interval Type 0~5047 0~5047 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NBR2GNCELL1NAME Neighbor 2G Cell 1 Name BSC6900 ADD GIBCAPNCGRP(Mandatory) Name of neighboring GSM cell 1 GBFD-117002IBCA (Interference Based Channel Allocation) String Type None 1~64 characters None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NBR2GNCELL2ID Neighbor 2G Cell 2 Index BSC6900 ADD GIBCAPNCGRP(Mandatory) Index of neighboring GSM cell 2. Uniform number of a cell index within a BSC, which uniquely identifies a cell and is in the range 0 to 5047. MRFD-210301Configuration Management Interval Type 0~5047 0~5047 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NBR2GNCELL2NAME Neighbor 2G Cell 2 Name BSC6900 ADD GIBCAPNCGRP(Mandatory) Name of neighboring GSM cell 2 GBFD-117002IBCA (Interference Based Channel Allocation) String Type None 1~64 characters None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NBR2GNCELLID Neighbor 2G Cell Index BSC6900 ADD G2GNCELL(Mandatory) Uniform number of a cell index within a BSC, which uniquely identifies a cell MRFD-210301Configuration Management Interval Type 0~5047 0~5047 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NBR2GNCELLNAME Neighbor 2G Cell Name BSC6900 ADD G2GNCELL(Mandatory) Name of a cell MRFD-210301Configuration Management String Type None 1~64 characters None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NBR3GNCELLID Neighbor Cell Index BSC6900 ADD G3GNCELL(Mandatory) Uniform number of a neighboring cell index within a BSC, which uniquely identifies a cellThe value range of the index of a 3G external cell is 5048 to 8047. MRFD-210301Configuration Management Interval Type 5048~8047 5048~8047 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NBR3GNCELLNAME Neighbor Cell Name BSC6900 ADD G3GNCELL(Mandatory) Name of a neighboring cell MRFD-210301Configuration Management String Type None 1~64 characters None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NBRCELLSWITCH Neighbor Cell Plan Switch BSC6900 SET BTSAUTOPLANCFG(Optional) When this switch is on, it indicates that the data of the adjacent cell is generated automatically. When this switch is off, it indicates that these data must be configured manually. GBFD-510702Compact BTS Automatic Capacity Planning Enumeration Type OFF(OFF), ON(ON) OFF, ON None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NBRCI Neighbour Cell CI BSC6900 ADD G2GNCELL(Mandatory) Cell ID of a neighboring cell MRFD-210301Configuration Management Interval Type 0~65535 0~65535 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NBRLAC Neighbour Cell LAC BSC6900 ADD G2GNCELL(Mandatory) Local Area Code (LAC) of a neighboring cell MRFD-210301Configuration Management Interval Type 1~65533,65535 1~65533, 65535 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NBRMCC Neighbour Cell MCC BSC6900 ADD G2GNCELL(Mandatory) Mobile Country Code (MCC) of a neighboring cell MRFD-210301Configuration Management String Type None 1~3 characters None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NBRMNC Neighbour Cell MNC BSC6900 ADD G2GNCELL(Mandatory) Mobile Network Code (MNC) of a neighboring cell MRFD-210301Configuration Management String Type None 1~3 characters None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NBRSPT64 Support 64 Neighbour Cells BSC6900 SET GCELLGPRS(Optional) Whether the PCU of the cell supports the 64 neighboring cells. This parameter determines the capability of reporting the number of the neighboring cells of the BSC in the NACC and NC2 function. GBFD-116201GBFD-116301 Network-Controlled Cell Reselection (NC2)Network Assisted Cell Change (NACC) Enumeration Type NO(No), YES(Yes)NO, YES None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NC2LoadResel NC2 Load Reselection Switch BSC6900 SET BSCPSSOFTPARA(Optional) Whether to support NC2 load reselection. GBFD-116201Network-Controlled Cell Reselection (NC2) Enumeration Type NotSupport(Not Support), Support(Support) NOTSUPPORT, SUPPORT None None NOTSUPPORT BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter is valid only when "NC2SPT" in "SET GCELLGPRS" is set to YES and "NCO" in "SET GCELLPSBASE" is set to NC2.
NC2SPT Support NC2 BSC6900 SET GCELLGPRS(Optional) Whether to support the network control 2 (NC2). The NC2 enables the network side to control the cell reselection for the MS when the MS reports the measurement report of the local cell and the neighboring cell. GBFD-116201Network-Controlled Cell Reselection (NC2) Enumeration Type NO(No), YES(Yes)NO, YES None None None Cell This parameter is valid only when "GPRS" is set to SupportAsInnPcu or SupportAsExtPcu. Read & Write Y Cell Less than 5 minutes None
NCC NCC BSC6900 ADD GCELL(Optional)ADD GEXT2GCELL(Mandatory) Network color code that is provided by the telecom operator. The NCC is used to identify networks from area to area. The NCC is unique nationwide.The BCC and the NCC form the BSIC. MRFD-210301Configuration Management Interval Type 0~7 0~7 None None None Cell None Read & Write Y Cell Less than 5 minutes None
NCC NCC BSC6900 ADD GCELLQUICKSETUP(Optional) Network color code. It is used to uniquely identify different public land mobile network (PLMN) of the adjacent country. GBFD-510701Compact BTS Automatic Configuration and Planning Interval Type 0~7 0~7 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NCCPERMIT NCC Permitted BSC6900 SET GCELLIDLEBASIC(Optional) A set of NCCs of the cells to be measured by the MS. This parameter is an information element (IE) in the system information type 2 and 6 messages. If a bit of the value of this parameter is set to 1, the MS reports the corresponding measurement report to the BTS. The value of this parameter has a byte (eight bits). Each bit maps with an NCC (0~7) and the most significant bit corresponds to NCC 7. If bit N is 0, the MS does not measure the cell level of NCC N. GBFD-110401GBFD-110402 Basic Cell SelectionBasic Cell Re-selection Bit Field Type SELECTION0_PERM, SELECTION1_PERM, SELECTION2_PERM, SELECTION3_PERM, SELECTION4_PERM, SELECTION5_PERM, SELECTION6_PERM, SELECTION7_PERM SELECTION0_PERM, SELECTION1_PERM, SELECTION2_PERM, SELECTION3_PERM, SELECTION4_PERM, SELECTION5_PERM, SELECTION6_PERM, SELECTION7_PERM None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NCCPERMITED NCC_PERMITTED BSC6900 SET GCELLEXTMSRPARA(Optional) NCC bitmap of the measurement report sent by the MS. The MS reports only the NCC bitmap of the BSIC and the cell measurement report that matches the bitmap. GBFD-110801GBFD-110802 Processing of Measurement ReportPre-processing of Measurement Report Interval Type 0~255 0~255 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NCELLFILTER Neighbor cell filter length mr number BSC6900 SET GCELLHOFAST(Optional) For the purpose of accurately reflecting the radio environment of a network, filtering is performed on the measured values in several consecutive measurement reports. This parameter indicates the number of measurement reports used for the filtering of neighboring cell information. GBFD-510102Fast Move Handover Interval Type 1~20 1~20, step:480 for TCH and 470 for SDCCH ms None 4 Cell This parameter is valid only when "QUICKHOEN" in "SET GCELLHOBASIC" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NCELLFLTLEN Filter Length for Ncell RX_LEV BSC6900 SET GCELLHOFITPEN(Optional) For the purpose of accurately reflecting the radio environment of a network, filtering is performed on the measured values in several consecutive measurement reports. This parameter indicates the number of measurement reports used for the filtering of neighboring cell signal strength. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 1~31 1~31, step:480 for TCH and 470 for SDCCH ms None 4 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NcellInterFLevelThres0 NeighborCell interfere Level Thresh 0 BSC6900 SET OTHSOFTPARA(Optional) Neighboring cell interference level threshold 0 GBFD-5109012G/3G Neighboring Cell Automatic Optimization Interval Type 0~127 0~127 dB None 0 BSC6900The following condition must be met: "NcellInterFLevelThres1" > "NcellInterFLevelThres0". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NcellInterFLevelThres1 NeighborCell interfere Level Thresh 1 BSC6900 SET OTHSOFTPARA(Optional) Neighboring cell interference level threshold 1 GBFD-5109012G/3G Neighboring Cell Automatic Optimization Interval Type 0~127 0~127 dB None 49 BSC6900The following condition must be met: "NcellInterFLevelThres2" > "NcellInterFLevelThres1" > "NcellInterFLevelThres0". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NcellInterFLevelThres2 NeighborCell interfere Level Thresh 2 BSC6900 SET OTHSOFTPARA(Optional) Neighboring cell interference level threshold 2 GBFD-5109012G/3G Neighboring Cell Automatic Optimization Interval Type 0~127 0~127 dB None 55 BSC6900The following condition must be met: "NcellInterFLevelThres3" > "NcellInterFLevelThres2" > "NcellInterFLevelThres1". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NcellInterFLevelThres3 NeighborCell interfere Level Thresh 3 BSC6900 SET OTHSOFTPARA(Optional) Neighboring cell interference level threshold 3 GBFD-5109012G/3G Neighboring Cell Automatic Optimization Interval Type 0~127 0~127 dB None 61 BSC6900The following condition must be met: "NcellInterFLevelThres4" > "NcellInterFLevelThres3" > "NcellInterFLevelThres2". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NcellInterFLevelThres4 NeighborCell interfere Level Thresh 4 BSC6900 SET OTHSOFTPARA(Optional) Neighboring cell interference level threshold 4 GBFD-5109012G/3G Neighboring Cell Automatic Optimization Interval Type 0~127 0~127 dB None 64 BSC6900The following condition must be met: "NcellInterFLevelThres5" > "NcellInterFLevelThres4" > "NcellInterFLevelThres3". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NcellInterFLevelThres5 NeighborCell interfere Level Thresh 5 BSC6900 SET OTHSOFTPARA(Optional) Neighboring cell interference level threshold 5 GBFD-5109012G/3G Neighboring Cell Automatic Optimization Interval Type 0~127 0~127 dB None 67 BSC6900The following condition must be met: "NcellInterFLevelThres6" > "NcellInterFLevelThres5" > "NcellInterFLevelThres4". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NcellInterFLevelThres6 NeighborCell interfere Level Thresh 6 BSC6900 SET OTHSOFTPARA(Optional) Neighboring cell interference level threshold 6 GBFD-5109012G/3G Neighboring Cell Automatic Optimization Interval Type 0~127 0~127 dB None 73 BSC6900The following condition must be met: "NcellInterFLevelThres7" > "NcellInterFLevelThres6" > "NcellInterFLevelThres5". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NcellInterFLevelThres7 NeighborCell interfere Level Thresh 7 BSC6900 SET OTHSOFTPARA(Optional) Neighboring cell interference level threshold 7 GBFD-5109012G/3G Neighboring Cell Automatic Optimization Interval Type 0~127 0~127 dB None 79 BSC6900The following condition must be met: "NcellInterFLevelThres7" > "NcellInterFLevelThres6". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NCHOCBLOCKNUM NCH Occupy Block Number BSC6900 SET GCELLGSMR(Optional) Number of blocks occupied by the NCH in the group call service GBFD-510301GBFD-510302 Public Voice Group Call ServicePublic Voice Broadcast Service Interval Type 0~7 0~7 None None None Cell The setting of this parameter must meet the following condition: "NCHSTARTBLOCK"" <= "NCHOCBLOCKNUM". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NCHSTARTBLOCK NCH Start Block BSC6900 SET GCELLGSMR(Optional) Number of the start block occupied by the NCH in the group call service GBFD-510301GBFD-510302 Public Voice Group Call ServicePublic Voice Broadcast Service Interval Type 0~7 0~7 None None None Cell The setting of this parameter must meet the following condition: "NCHSTARTBLOCK"" <= "NCHOCBLOCKNUM". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NCO Network Control Mode BSC6900 SET GCELLPSBASE(Optional) Network control mode for cell reselection of the MS. There are three modes. NC0: normal MS control. The MS shall perform autonomous cell re-selection. NC1: MS control with measurement reports. The MS shall send measurement reports to the network and the MS shall perform autonomous cell re-selection. NC2: network control. The MS shall send measurement reports to the network . The MS shall only perform autonomous cell re-selection when the reselection is triggered by a downlink signalling failure or a random access failure. GBFD-119107Networking Control Mode Enumeration Type nc0(nc0), nc1(nc1), nc2(nc2) nc0, nc1, nc2 None None nc0 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NEIGHBOR Adjacent flag BSC6900 ADD N7DPC(Optional) The DSP and OSP are in the associated mode or non associated mode. None None Enumeration Type NO(NO_DIRECT_CONNECT), YES(DIRECT_CONNECT) NO, YES None YES YES SCCP None Read & Write Y BSC6900 Less than 10 minutes None
NETMASK Net Mask BSC6900 ADD XPUVLAN(Mandatory) IP address mask of the VLAN MRFD-210301Configuration Management IP Address Type None 0.0.0.0~255.255.255.255 None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NEWURGHOMININTV Min Interval for Emerg.Hos BSC6900 SET GCELLHOCTRL(Optional) Minimum interval between two consecutive emergency handovers performed by an MS. During this interval, no emergency handover is allowed. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 0~60 0~60 s None 4 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NEXTHOP Forward Route Address BSC6900 ADD OMUIPRT(Mandatory) IP address of the next hop. None None IP Address Type None 0.0.0.0~255.255.255.255 None None None BSC6900None Read & Write Not involved Not involved Not involved None
NEXTHOP Forward route address BSC6900 ADD IPRT(Mandatory) Next hop None None IP Address Type None 0.0.0.0~255.255.255.255 None None None IP route None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
NEXTHOP Forward route address BSC6900 ADD IPRTBIND(Mandatory) Next hop None None IP Address Type None 0.0.0.0~255.255.255.255 None None None None None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
NEXTHOP Forward route address BSC6900 ADD BTSIPRT(Mandatory)ADD BTSIPRTBIND(Mandatory) IP address of the next hop GBFD-118611Abis IP over E1/T1 IP Address Type None 0.0.0.0~255.255.255.255 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NI Network ID BSC6900 ADD OPC(Mandatory) Network ID. None None Enumeration Type INT(INT), INTB(INTB), NAT(NAT), NATB(NATB) INT, INTB, NAT, NATBNone None None SCCP This parameter depends on network planning. Read & Write Not involved Not involved Not involved The parameter cannot be modified.
NM Download file name BSC6900 DLD TCFILE(Mandatory) Name of the file to be downloaded. The file name must be complete and does not contain a wildcard. MRFD-210301Configuration Management String Type None 1~62 characters None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NMO Network Operation Mode BSC6900 SET GCELLPSBASE(Optional) This parameter is related to the paging channel of the system. There are three network operation modes: network operation mode I, network operation mode II, and network operation mode III. Network operation mode I is used when the system is configured with the Gs interface. Network operation mode II is used when the system is not configured with the Gs interface and the PCCCH is not configured. Network operation mode III is used when the system is not configured with the Gs interface and the PCCCH is configured. GBFD-119108Network Operation Mode Support Enumeration Type NMOI(Network Operation Mode I), NMOII(Network Operation Mode II), NMOIII(Network Operation Mode III), RES(Reserved) NMOI, NMOII, NMOIII, RES None None NMOII Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NO1M48ALMTHDDOWN Lower limit of No.1 input -48V[-V] BSC6900 SET PWRPARA(Optional) Lower limit of input voltage 1 MRFD-210304Faulty Management Interval Type 40~45 40~45 V None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NO1M48ALMTHDUP Upper limit of No.1 input -48V[-V] BSC6900 SET PWRPARA(Optional) Upper limit of input voltage 1 MRFD-210304Faulty Management Interval Type 55~59 55~59 V None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NO2M48ALMTHDDOWN Lower limit of No.2 input -48V[-V] BSC6900 SET PWRPARA(Optional) Lower limit of input voltage 2 MRFD-210304Faulty Management Interval Type 40~45 40~45 V None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NO2M48ALMTHDUP Upper limit of No.2 input -48V[-V] BSC6900 SET PWRPARA(Optional) Upper limit of input voltage 2 MRFD-210304Faulty Management Interval Type 55~59 55~59 V None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NO3M48ALMTHDDOWN Lower limit of No.3 input -48V[-V] BSC6900 SET PWRPARA(Optional) Lower limit of input voltage 3 MRFD-210304Faulty Management Interval Type 40~45 40~45 V None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NO3M48ALMTHDUP Upper limit of No.3 input -48V[-V] BSC6900 SET PWRPARA(Optional) Upper limit of input voltage 3 MRFD-210304Faulty Management Interval Type 55~59 55~59 V None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NO4M48ALMTHDDOWN Lower limit of No.4 input -48V[-V] BSC6900 SET PWRPARA(Optional) Lower limit of input voltage 4 MRFD-210304Faulty Management Interval Type 40~45 40~45 V None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NO4M48ALMTHDUP Upper limit of No.4 input -48V[-V] BSC6900 SET PWRPARA(Optional) Upper limit of input voltage 4 MRFD-210304Faulty Management Interval Type 55~59 55~59 V None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NO5M48ALMTHDDOWN Lower limit of No.5 input -48V[-V] BSC6900 SET PWRPARA(Optional) Lower limit of input voltage 5 MRFD-210304Faulty Management Interval Type 40~45 40~45 V None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NO5M48ALMTHDUP Upper limit of No.5 input -48V[-V] BSC6900 SET PWRPARA(Optional) Upper limit of input voltage 5 MRFD-210304Faulty Management Interval Type 55~59 55~59 V None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NO6M48ALMTHDDOWN Lower limit of No.6 input -48V[-V] BSC6900 SET PWRPARA(Optional) Lower limit of input voltage 6 MRFD-210304Faulty Management Interval Type 40~45 40~45 V None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NO6M48ALMTHDUP Upper limit of No.6 input -48V[-V] BSC6900 SET PWRPARA(Optional) Upper limit of input voltage 6 MRFD-210304Faulty Management Interval Type 55~59 55~59 V None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NOAMRFULLTOHALFHOALLOW Non-AMR F-H Ho Allowed BSC6900 SET GCELLHOBASIC(Optional) Whether to allow non-AMR voice F-H handover GBFD-510501HUAWEI II Handover Enumeration Type NO(No), YES(Yes)NO, YES None None NO Cell This parameter is valid only when "HOCTRLSWITCH" is set to HOALGORITHM2. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NOAMRFULLTOHALFHOATCBADJSTEP Non-AMR F-H Ho ATCB Adjust Step BSC6900 SET GCELLHOBASIC(Optional) Decides the offset of the current ATCB together with other two parameters: "F-H Ho Period" and period of triggering a F-H handover, thus selecting target users for F-H handovers. ATCB offset = (Period of triggering a F-H handover / "F-H Ho Period" + 1) * "Non-AMR F-H Ho ATCB Adjust Step". GBFD-510501HUAWEI II Handover Interval Type 0~255 0~255 dB None 2 Cell This parameter is valid only when "HOCTRLSWITCH" is set to HOALGORITHM2 and "NOAMRFULLTOHALFHOALLOW" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NOAMRFULLTOHALFHOATCBTHRESH Non-AMR F-H Ho ATCB Threshold BSC6900 SET GCELLHOBASIC(Optional) When the ATCB value of non-AMR full rate voice is no smaller than this parameter, the condition for non-AMR F-H handovers is met. GBFD-510501HUAWEI II Handover Interval Type 0~255 0~255 dB None 30 Cell This parameter is valid only when "HOCTRLSWITCH" is set to HOALGORITHM2 and "NOAMRFULLTOHALFHOALLOW" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NOAMRFULLTOHALFHOPATHADJSTEP Non-AMR F-H Ho Pathloss Adjust Step BSC6900 SET GCELLHOBASIC(Optional) Decides the current path cost offset together with other two parameters: "F-H Ho Period" and period of triggering a F-H handover, thus selecting target users for F-H handovers. Path cost offset = (Period of triggering a F-H handover / "F-H Ho Period" + 1) * "Non-AMR F-H Ho Pathloss Adjust Step". GBFD-510501HUAWEI II Handover Interval Type 0~255 0~255 dB None 1 Cell This parameter is valid only when "HOCTRLSWITCH" is set to HOALGORITHM2 and "NOAMRFULLTOHALFHOALLOW" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NOAMRFULLTOHALFHOPATHTHRESH Non-AMR F-H Ho Pathloss Threshold BSC6900 SET GCELLHOBASIC(Optional) When the path loss value of non-AMR full rate voice is no larger than this parameter, the condition for non-AMR F-H handovers is met. GBFD-510501HUAWEI II Handover Interval Type 0~255 0~255 dB None 95 Cell This parameter is valid only when "HOCTRLSWITCH" is set to HOALGORITHM2 and "NOAMRFULLTOHALFHOALLOW" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NOAMRFULLTOHALFHOQUALTHRESH Non-AMR F-H Ho Qual. Threshold BSC6900 SET GCELLHOBASIC(Optional) Quality threshold for non-AMR F-H handovers. When the uplink receive quality and downlink receive quality of a user are both smaller than this parameter, a F-H handover is triggered for the user. GBFD-510501HUAWEI II Handover Interval Type 0~7 0~7 None None 0 Cell This parameter is valid only when "HOCTRLSWITCH" is set to HOALGORITHM2 and "NOAMRFULLTOHALFHOALLOW" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NOAMRFULLTOHALFTHRESH Non-AMR F-H Traffic Threshold BSC6900 SET GCELLHOBASIC(Optional) When the load of a cell is no smaller than this threshold, non-AMR F-H handovers are triggered in the cell. GBFD-510501HUAWEI II Handover Interval Type 0~100 0~100 per cent None 85 Cell This parameter is valid only when "HOCTRLSWITCH" is set to HOALGORITHM2 and "NOAMRFULLTOHALFHOALLOW" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NOAMRHALFTOFULLHOATCBTHRESH Non-AMR H-F Ho ATCB Threshold BSC6900 SET GCELLHOBASIC(Optional) When the ATCB value of non-AMR half rate voice is no larger than this threshold, the condition for non-AMR H-F handovers is met. GBFD-510501HUAWEI II Handover Interval Type 0~255 0~255 dB None 14 Cell This parameter is valid only when "HOCTRLSWITCH" is set to HOALGORITHM2 and "NOAMRFULLTOHALFHOALLOW" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NOAMRHALFTOFULLHOPATHTHRESH Non-AMR H-F Ho Pathloss Threshold BSC6900 SET GCELLHOBASIC(Optional) When the path loss value of non-AMR half rate voice is no smaller than this threshold, the condition for non-AMR H-F handovers is met. GBFD-510501HUAWEI II Handover Interval Type 0~255 0~255 dB None 103 Cell This parameter is valid only when "HOCTRLSWITCH" is set to HOALGORITHM2 and "NOAMRFULLTOHALFHOALLOW" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NOAMRHALFTOFULLHOQUALALLOW Non-AMR H-F Qaul. Ho Allowed BSC6900 SET GCELLHOBASIC(Optional) Whether to trigger non-AMR H-F handovers according to the uplink and downlink receive quality. GBFD-510501HUAWEI II Handover Enumeration Type NO(No), YES(Yes)NO, YES None None NO Cell This parameter is valid only when "HOCTRLSWITCH" is set to HOALGORITHM2 and "NOAMRFULLTOHALFHOALLOW" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NOAMRHALFTOFULLHOQUALTHRESH Non-AMR H-F Ho Qual. Threshold BSC6900 SET GCELLHOBASIC(Optional) Quality threshold for non-AMR H-F handovers. When the receive quality of a user is no smaller than this parameter, the user meets the condition for H-F handovers. GBFD-510501HUAWEI II Handover Interval Type 0~7 0~7 None None 2 Cell This parameter is valid only when "HOCTRLSWITCH" is set to HOALGORITHM2 and "NOAMRFULLTOHALFHOALLOW" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NOAMRHALFTOFULLTHRESH Non-AMR H-F Traffic Threshold BSC6900 SET GCELLHOBASIC(Optional) When the load of a cell is no larger than this threshold, non-AMR H-F handovers are triggered in the cell. GBFD-510501HUAWEI II Handover Interval Type 0~100 0~100 per cent None 25 Cell This parameter is valid only when "HOCTRLSWITCH" is set to HOALGORITHM2 and "NOAMRFULLTOHALFHOALLOW" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NODEBID NodeB ID BSC6900 ADD ADJNODE(Mandatory) Node ID of the adjacent node to be added. The parameter is valid when Adjacent node type is set to IUB. None None Interval Type 0~65535 0~65535 None None None Adjacent node When the value of "NODET" in "ADD ADJNODE" is set to IUB, this parameter is valid. Read & Write Not involved Not involved Not involved The parameter cannot be modified.
NODET Adjacent Node Type BSC6900 ADD ADJNODE(Mandatory) Adjacent node type None None Enumeration Type IUB(Iub Interface), IUR(Iur Interface), IUCS(Iu-CS Interface), IUPS(Iu-PS Interface), UNI_AAL2SWITCH(the adjacent node of the ATM switch on the Iub interface), NNI_AAL2SWITCH(the adjacent node of ATM switch on Iur or Iu-CS interface), ABIS(Abis Interface), A(A Interface), BSC(Ater Interface on BSC), TC(Ater Interface on TC) IUB, IUR, IUCS, IUPS, UNI_AAL2SWITCH, NNI_AAL2SWITCH, ABIS, A, BSC, TC None None None Adjacent node None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
NODLMRHOALLOWLIMIT Cons.No Dl Mr.HO Allowed Limit BSC6900 SET GCELLHOEMG(Optional) Decisions of no-downlink measurement report handovers can be made only when the number of consecutive no-downlink measurement reports in the current call is no larger than this parameter. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 0~64 0~64 None None 8 Cell This parameter is valid only when "NODLMRHOEN" in "SET GCELLHOEMG" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NODLMRHOEN No Dl Mr.HO Allowed BSC6900 SET GCELLHOEMG(Optional) Whether to enable the no-downlink measurement report handover algorithm. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Enumeration Type NO(No), YES(Yes)NO, YES None None NO Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NODLMRHOQUALLIMIT No Dl Mr.Ul Qual HO Limit BSC6900 SET GCELLHOEMG(Optional) When a certain number of no-downlink measurement reports are received consecutively and the uplink receive quality is no smaller than this parameter, no-downlink measurement report emergency handovers are triggered. No-downlink measurement report emergency handovers choose the inter-cell handover mode preferentially; however, if no candidate cells are available and intra-cell handover is enabled in the current cell, intra-cell handovers are triggered. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 0~70 0~70 None None 50 Cell This parameter is valid only when "NODLMRHOEN" in "SET GCELLHOEMG" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NOMINALCAPACITY Norminal Capacity{AH} BSC6900 SET BTSPMUBP(Optional) Normal output capacity of the battery group in specific discharging conditions (such as discharge rate, temperature, and final voltage). Generally, the parameter is based on 10-hour discharge rate. GBFD-111202O&M of BTS Interval Type 1~1000 1~1000 Ah 100 None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NONAMRCALLPCALLOWED Allow III Power Control For Non-AMR BSC6900 SET GCELLPWR3(Optional) Whether to enable the III power control algorithm for Non-AMR calls. If enabled, power control is performed on Non-AMR calls. GBFD-117601HUAWEI III Power Control Algorithm Enumeration Type OFF(Not Allowed), ON(Allowed) OFF, ON None None ON Cell This parameter is valid only when "PWRCTRLSW" in "SET GCELLPWRBASIC" is set to PWR3. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NONDRXPERIOD Non-DRX Period BSC6900 SET GCELLNWCTRLMSRPARA(Optional) Period when the cell is in the non-DRX state. GBFD-119107Networking Control Mode Enumeration Type NODRX(NODRX), 0.24sec(0.24sec), 0.48sec(0.48sec), 0.72sec(0.72sec), 0.96sec(0.96sec), 1.20sec(1.20sec), 1.44sec(1.44sec), 1.92sec(1.92sec) NODRX, 0.24sec, 0.48sec, 0.72sec, 0.96sec, 1.20sec, 1.44sec, 1.92sec s None 0.24sec Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NormalCurDurA A ALD Cur-Minor Alarm N-Cur Duration BSC6900 SET BTSRXUBP(Optional) When the ANT_A tributary antenna current abnormally check mode is set to Mode 3, the parameter ALD Current Prompt Alarm is checked by periodical pulse. The periodical pulse consists of antenna over-current duration and normal current duration. This parameter is the ANT_A tributary antenna normal current duration. MRFD-210304Faulty Management Interval Type 100~10000 100~10000 ms None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NormalCurDurB B ALD Cur-Minor Alarm N-Cur Duration BSC6900 SET BTSRXUBP(Optional) When the ANT_B tributary antenna current abnormally check mode is set to Mode 3, the parameter ALD Current Prompt Alarm is checked by periodical pulse. The periodical pulse consists of antenna over-current duration and normal current duration. This parameter is the ANT_B tributary antenna normal current duration. MRFD-210304Faulty Management Interval Type 100~10000 100~10000 ms None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NORMALRESELALLOW Cell Normal Reselection Allowed BSC6900 SET GCELLNC2PARA(Optional) Whether to allow the cell normal reselection. GBFD-116201Network-Controlled Cell Reselection (NC2) Enumeration Type FORBID(Forbid), PERMIT(Permit) FORBID, PERMIT None None PERMIT Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NORTHD Normal Work TEMP Threshold BSC6900 SET BTSCABPARA(Optional) Normal work temperature threshold of the cabinet GBFD-111202O&M of BTS Interval Type 400~700 40~70 (step: 0.1) degree Celsius None 500 BTS The value of this parameter must be 8C smaller than "Derating TEMP Threshold". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NOTMSIALLCELLPAGINGLIMITFLAG Discard TMSI All Cell Paging BSC6900 SET OTHSOFTPARA(Optional) Whether to discard paging messages without TMSIs and all-cell paging messages that considerably increase the load on the BSC system GBFD-111705GSM Flow Control Enumeration Type CLOSE(Close), OPEN(Open) CLOSE, OPEN None None CLOSE BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NOTRASP Statistical Period of No-traffic BSC6900 SET GTRXRLALM(Optional) Maximum number of measurement periods in which there is no traffic. If the number of measurement periods in which there is no traffic reaches this parameter, the BTS reports an alarm indicating that there is no traffic. GBFD-111004Radio Dedicated Channel Management Interval Type 1~255 1~255, step:5 min None 48 TRX This parameter is valid only when "WLNKALMFLAG" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NOVGCSTIME No VGCS Call Time BSC6900 SET BTSFALLBACK(Optional) If the BTS works in fallback mode and uplink VGCS connection is idle for a period specified by this parameter, the BTS disables the VGCS connection automatically. This parameter is valid only for user-originated VGCS calls and is invalid for fixed VGCS calls. GBFD-510309Group Call Reliability Enhancing Interval Type 10~255 10~255 s None 30 BTS This parameter is valid only when "ENABLE" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter is supported only by the following dual-density BTSs: BTS3012, BTS3006C, BTS3012AE, BTS3012 II, and BTS3002E.
NQUERIES Number of TRACERT Packages Per TTL BSC6900 TRC IPADDR(Optional) Number of TRACERT packets sent to each TTL None None Interval Type 1~10 1~10 None 3 3 None None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
NRBSDCCHFFLEN Filter length for sdcch nbr_rcvd_block BSC6900 SET GCELLHOFITPEN(Optional) For the purpose of accurately reflecting the radio environment of a network, filtering is performed on the measured values in several consecutive measurement reports. This parameter indicates the number of enhanced measurement reports received on a signaling channel used to filter the NBR_RCVD_BLOCKS value. GBFD-117501Enhanced Measurement Report(EMR) Interval Type 0~31 0~31, step:480 for TCH and 470 for SDCCH ms None 2 Cell This parameter is valid only when "MEASURETYPE" in "SET GCELLCCUTRANSYS" is set to EnhMeasReport. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NRBTCHFFLEN Filter length for tch nbr_rcvd_block BSC6900 SET GCELLHOFITPEN(Optional) For the purpose of accurately reflecting the radio environment of a network, filtering is performed on the measured values in several consecutive measurement reports. This parameter indicates the number of enhanced measurement reports received on a service channel used to filter the NBR_RCVD_BLOCKS value. GBFD-117501Enhanced Measurement Report(EMR) Interval Type 0~31 0~31, step:480 for TCH and 470 for SDCCH ms None 6 Cell This parameter is valid only when "MEASURETYPE" in "SET GCELLCCUTRANSYS" is set to EnhMeasReport. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NRI NRI Value BSC6900 ADD NRIMSCMAP(Mandatory) Network resource indication that specifies a CN node in the MSC pool GBFD-117401MSC Pool Interval Type 0~1023 0~1023 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NRI NRI Value BSC6900 ADD NRISGSNMAP(Mandatory) Identifies the mapping relation from the NRI to the SGSN uniquely with the operator name. GBFD-119701SGSN Pool Interval Type 0~1023 0~1023 None None None BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NRofFDDCellFlag Support NR_of_FDD_cells Writing BSC6900 SET OTHSOFTPARA(Optional) Controls the values of the FDD_Indic0 field, the NR_OF_FDD_CELLS field, and the FDD_Cellinformation field in 2quater and MI when 3G neighboring cells with scrambling code 0 are present. When this parameter is set to YES, FDD_Indic0 is set to 1, the NR_OF_FDD_CELLS count does not include cells with scrambling code 0, and FDD_Cellinformation also does not include cells with scrambling code 0; When this parameter is set to NO, FDD_Indic0 is set to 1, the NR_OF_FDD_CELLS count includes cells with scrambling code 0, and FDD_Cellinformation also includes cells with scrambling code 0. GBFD-111101System Information Sending Enumeration Type NO(No), YES(Yes)NO, YES None None YES BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NSEI NSE Identifier BSC6900 ADD NSE(Mandatory)ADD NSVC(Mandatory)ADD NSVLLOCAL(Mandatory)ADD NSVLREMOTE(Mandatory)ADD PTPBVC(Mandatory)BLK PTPBVC(Mandatory) Identifies a unique NSE. GBFD-119001Gb Interface Function Interval Type 0~65534 0~65534 None None None NSE None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
NSEI NSE identifier BSC6900 ADD GCELLQUICKSETUP(Optional) NSE identifier GBFD-119001Gb Interface Function Interval Type 0~65534 0~65534 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NSIGSTRFLTLEN NCell filter length for SDCCH level BSC6900 SET GCELLHOFITPEN(Optional) For the purpose of accurately reflecting the radio environment of a network, filtering is performed on the measured values in several consecutive measurement reports. This parameter indicates the number of measurement reports received on signaling channels used for the filtering of neighboring cell signal strength. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 1~31 1~31, step:480 for TCH and 470 for SDCCH ms None 2 Cell This parameter is valid only when "HOCTRLSWITCH" in "SET GCELLHOBASIC" is set to HOALGORITHM2. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NSLATI NS Latitude BSC6900 SET GCELLLCS(Optional) Whether the cell is located in the south latitude or north latitude GBFD-115402BSS-Based LCS (Cell ID + TA) Enumeration Type North_latitude(North latitude), South_latitude(South latitude) North_latitude, South_latitude None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NSVCI NSVC Identifier BSC6900 ADD NSVC(Mandatory) NSVC ID, identifies a unique NSVC. This ID must be negotiated with the peer SGSN. GBFD-510002Gb Over FR Interval Type 0~65534 0~65534 None None None NSVC None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
NSVCIDX NSVC Index BSC6900 ADD NSVC(Mandatory)BLK NSVC(Mandatory) NSVC index, identifies a unique NSVC. GBFD-510002Gb Over FR Interval Type 0~1023 0~1023 None None None NSVC None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
NTDI Normal Temperature Delta Tin BSC6900 SET BTSDHEUBP(Optional) If the inlet temperature is between "High Temperature Critical Point" and "Low Temperature Critical Point" and the difference between the inlet temperature and the ambient temperature reaches the value of this parameter, the temperature control system controls the difference between the inlet and outlet temperatures as well as the difference between the inlet temperature and the ambient temperature.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. GBFD-111202O&M of BTS Interval Type 0~30 0~30 degree Celsius None 9 BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NTDO Normal Temperature Delta Tout BSC6900 SET BTSDHEUBP(Optional) If the outlet temperature is between "High Temperature Critical Point" and "Low Temperature Critical Point" and the difference between the outlet temperature and the inlet temperature reaches the value of this parameter, the temperature control system controls the difference between the inlet and outlet temperatures as well as the difference between the inlet temperature and the ambient temperature.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. GBFD-111202O&M of BTS Interval Type 0~30 0~30 degree Celsius None 16 BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
NUM Fault NodeB number BSC6900 SET FACFG(Mandatory) Fault NodeB number when restore interface board to judge fault port. MRFD-210304Faulty Management Interval Type 0~10 0~10 None None None None None Read & Write Not involved Not involved Not involved None
NY2 Ny2 BSC6900 SET GCELLGSMR(Optional) Number of retransmissions of the VGCS UPLINK GRANT message GBFD-510301Public Voice Group Call Service Interval Type 1~255 1~255 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
OAMFLOWBW OAM flow min bandwidth[%] BSC6900 SET ETHPORT(Optional) Ratio of the minimum guarantee bandwidth of the OAM stream to the port bandwidth None None Interval Type 0~100 0~100 per cent None None Ethernet port None Read & Write Y Ethernet port If the value is too big, will interrupt service until it is set to the normal value. If this parameter is set to a larger value, the bandwidth of the service is smaller.
OAMFLOWBW OAM flow min bandwidth[%] BSC6900 ADD PPPLNK(Optional) Minimum guarantee bandwidth of the OAM stream GBFD-118611GBFD-118622 Abis IP over E1/T1A IP over E1/T1 Interval Type 0~100 0~100 per cent 0 0 PPP link None Read & Write Y BSC6900 Interrupt the service until negotiate successfully again. Negotiation can succeed only when the configuration is consistent on the local and peer ends.
OAMFLOWBW OAM flow min bandwidth[%] BSC6900 ADD MPGRP(Optional) Minimum guarantee bandwidth of the OAM stream GBFD-118611GBFD-118622 Abis IP over E1/T1A IP over E1/T1 Interval Type 0~100 0~100 per cent 0 0 MP groupNone Read & Write N (No impact on the UE in idle mode) Not involved Not involved Negotiation can succeed only when the configuration is consistent on the local and peer ends.
OAMFLOWBW OAM flow min bandwidth[%] BSC6900 ADD IPLOGICPORT(Optional) Minimum guarantee bandwidth of the OAM stream None None Interval Type 0~100 0~100 per cent 0 0 IP logical port None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
OAMFLOWBW OAM flow min bandwidth[%] BSC6900 ADD ETHTRK(Optional) Ratio of the minimum guarantee bandwidth of the OAM stream to the port bandwidth MRFD-210103Link aggregation Interval Type 0~100 0~100 per cent 0 0 Ethernet port None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
OAMFLOWDSCP DSCP of OAM flow BSC6900 SET QUEUEMAP(Mandatory) DSCP value of the OAM stream. The data of the OAM stream are not added to queues 1 to 6 for transmission. Instead, the data of the OAM stream is added to the dedicated queue. None None Interval Type 0~63 0~63 None None None Port queue None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The transmission priority of the service is affected if the queue DSCP value of the port is modified.
OAMMINBWKEY OAM flow min bandwidth switch BSC6900 SET QUEUEMAP(Optional) Minimum guarantee bandwidth switch of the OAM stream None None Enumeration Type OFF(OFF), ON(ON) OFF, ON None None None Port queue None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The transmission priority of the service is affected if the queue DSCP value of the port is modified.
OBJECTTYPE Operate Object BSC6900 SET BTSANTANGLE(Mandatory) Operation object MRFD-210602Remote Electrical Tilt Enumeration Type SITE(SITE), CELL(CELL), BOARD(BOARD) SITE, CELL, BOARD None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
OBJECTTYPE Object Type BSC6900 STR TRXBURSTTST(Mandatory) Type of the object GBFD-111207BTS Test Function Enumeration Type BYCELL(By CELL), BYTRX(By TRX) BYCELL, BYTRX None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
OBJTP Object Type BSC6900 ADD OBJALMSHLD(Mandatory) Shield type of the alarm. "ALL" indicates one shield type instead of all types. MRFD-210304Faulty Management Enumeration Type ALL(Shield by alarm id), BOARD(Shield by board), PORT(Shield by port), DSP(Shield by dsp) ALL, BOARD, PORT, DSP None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
OBJTP Object Type BSC6900 ADD BTSOBJALMSHLD(Mandatory) Type of the alarm shield object MRFD-210304Faulty Management Enumeration Type BTS(BTS), CELL(CELL), LOC(LOC), BOARD(BOARD), PORT(PORT) BTS, CELL, LOC, BOARD, PORT None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
OBJTYPE Object Type BSC6900 SET FHO(Mandatory) Object index types used when commands are executed MRFD-210301Configuration Management Enumeration Type CELL(Cell), TRX(TRX), CHN(Channel) CELL, TRX, CHN None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
OccupyStreamingSwitch Occupy Switch of Streaming Resource BSC6900 SET GCELLPSOTHERPARA(Optional) When the PDCHs are insufficient, the streaming service with high priority can preempt the PDCHs that are seized by the streaming service with low priority. After the PDCH resource preemption, the streaming service with low priority initiates the QoS negotiation with the SGSN. If the QoS negotiation fails, or if all the PDCHs are preempted, then the streaming service with low priority is disrupted. GBFD-119901Streaming QoS(GBR) Enumeration Type OFF(OFF), ON(ON) OFF, ON None None OFF Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
OLTOULHOALLOW OL to UL HO Allowed BSC6900 SET GCELLHOIUO(Optional) Whether to allow overlay-to-underlay handovers GBFD-113201Concentric Cell Enumeration Type NO(No), YES(Yes)NO, YES None None YES Cell This parameter is valid only when "IUOTP" in "ADD GCELL" is set to Concentric_cell. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
OMLBKUP Configure backup OML BSC6900 SET BTSOMLBACKUP(Optional) Whether to enable OML backup for the BTS GBFD-113728OML Backup Enumeration Type NO(No), YES(Yes)NO, YES None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
OmlDetectTime OML Lapd Link Detect Time BSC6900 SET OTHSOFTPARA(Optional) This parameter specifies the detecting time of Abis-Bypass site OML when it is broken. GBFD-116601Abis Bypass Interval Type 4~255 4~255 s None 10 BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved If the parameter value is set relatively small, the sensitivity for detecting the OML when it is broken is improved. When the parameter value is set too small and if the link is intermittently disconnected, misjudgements may occur to the testing results.If the parameter value is set relatively large, the sensitivity for detecting the OML when it is broken is reduced. The testing results are reliable, though.
OMLDSCP OML DSCP BSC6900 SET BTSABISPRIMAP(Optional) Differentiated service code of the specified OML None None Interval Type 0~63 0~63 None None None BSC6900None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
OMLESLDL OMLESLDL BSC6900 SET BTSBWPARA(Mandatory) The summation of average down-bandwidth of OML&ESL link in BTS. GBFD-111202O&M of BTS Interval Type 0~256 0~256 kbit/s 64 None Transport channel None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
OMLESLUL OMLESLUL BSC6900 SET BTSBWPARA(Mandatory) The summation of average up-bandwidth of OML&ESL link in BTS. GBFD-111202O&M of BTS Interval Type 0~256 0~256 kbit/s 64 None Transport channel None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
OMLPRI OML Priority BSC6900 SET BTSABISPRIMAP(Optional) Service priority of the specified OML None None Interval Type 0~7 0~7 None None None BSC6900None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
OMLSBMSwitch OML SAMME Switch BSC6900 SET OTHSOFTPARA(Optional) Whether periodic SAMB frames are actively sent on the OML in the reverse ring in satellite transmission mode when the link in the forward ring in terrestrial transmission mode is normal GBFD-117803Abis Transmission Backup Enumeration Type OFF(Off), ON(On) OFF, ON None None OFF BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
OMLSP OML Service PRI BSC6900 SET BSCSRVPRI(Optional) Priority of services on the OML. The operation and maintenance link (OML) is used to transfer the OM information between the BSC and BTS. This parameter indicates the priority of services on the OML. GBFD-118605IP QOS Interval Type 0~7 0~7 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
OMLVLANID OML VlanId BSC6900 SET BTSABISPRIMAP(Optional) Specified OML Vlan Id None None Interval Type 2~4094 2~4094 None None None BSC6900None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
OMLWS OML/ESL/EML LAPD Window size BSC6900 SET BTSLAPDWS(Optional) Size of the OML/ESL/EML LAPD window GBFD-118601Abis over IP Interval Type 0~96 0~96 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
OMUIP OMU External Network Virtual IP BSC6900 ADD EMSIP(Optional) External virtual IP address of the OMU None None IP Address Type None 0.0.0.0~255.255.255.255 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
OMUMASK OMU External Network Mask BSC6900 ADD EMSIP(Optional) Subnet mask of the OMU in the external network None None IP Address Type None 0.0.0.0~255.255.255.255 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
OP Operator BSC6900 EXP LOG(Optional)ADD OP(Mandatory)ULK USR(Mandatory)ADD BTSOP(Mandatory) Account of the operator GBFD-111203MRFD-210305 O&M of BSCSecurity Management String Type None 1~32 characters None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
OPC OSP Code BSC6900 ADD GCELLOSPMAP(Mandatory) Code of the original signaling point (OSP) in the signaling network. In the signaling network, each signaling point is identified by a signaling point code. MRFD-210301GBFD-118701 Configuration ManagementRAN Sharing Interval Type 1~16777215 1~16777215 None None None BSC6900None Read & Write Y Cell Less than 5 minutes Before modifying this parameter, you must deactivate the cells bound to the OPC.
OPC OSP Code BSC6900 ADD GCELLQUICKSETUP(Mandatory) Code of the signaling point of the local office in the signaling network. In the signaling network, each signaling point has a corresponding signaling point code. GBFD-111202O&M of BTS Interval Type 1~16777215 1~16777215 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
OPCIDX OPC Index BSC6900 BLK ACIC(Mandatory)ADD AE1T1(Mandatory) OPC index GBFD-111803A Interface Circuit Management Interval Type 0~4 0~4 None None None E1/T1 linkNone Read & Write Not involved Not involved Not involved The parameter cannot be modified.
OperatorType Operator Type BSC6900 ADD GCNOPERATOR(Mandatory) Primary operator or secondary operator GBFD-118701RAN Sharing Enumeration Type PRIM(Primary Operator), SEC(Secondary Operator) PRIM, SEC None None None BSC6900None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
OPINDEX Operator Index BSC6900 ADD GCNOPERATOR(Mandatory) Index of the operator. This parameter uniquely identifies an operator. GBFD-117401MSC Pool Interval Type 0~3 0~3 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved Primary operator index must be 0.
OPINDEXSET OP INDEX SET BSC6900 ADD GCBSADDR(Mandatory) Operator index set to which the CBC belongs GBFD-118701RAN Sharing Bit Field Type OPINDEX0, OPINDEX1, OPINDEX2, OPINDEX3 OPINDEX0, OPINDEX1, OPINDEX2, OPINDEX3 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
OPMODE Operation Mode BSC6900 BLK ACIC(Mandatory) It is one key filed of identifying A interface CIC status and indicates the alignment mode of A interface circuit. GBFD-111803A Interface Circuit Management Enumeration Type BYCICRANGE(BY CIC RANGE), BYCICVALUE(BY CIC VALUE) BYCICRANGE, BYCICVALUE None None None E1/T1 linkNone Read & Write N (No impact on the UE in idle mode) Not involved Not involved 1. The block of A interface must be configured. 2. If A over IP is configured, the configuration does not support the operation.
OPMODE Operation Mode BSC6900 BLK PBCIC(Mandatory) It is one key filed of identifying Pb interface CIC status and indicates the Pb interface CIC. GBFD-111203O&M of BSC Enumeration Type BYCICRANGE(BY CIC RANGE), BYCICVALUE(BY CIC VALUE) BYCICRANGE, BYCICVALUE None None None PBCIC None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
OPMODE Operation Mode BSC6900 BLK ATERE1T1(Mandatory) It is one key filed of identifying Ater interface timeslot status and indicates the alignment mode of Ater interface circuit. GBFD-111801Ater Interface 4:1 Multiplexing Enumeration Type BYTSRANGE(BY TS RANGE), BYTSVALUE(BY TS VALUE) BYTSRANGE, BYTSVALUE None None None E1/T1 linkNone Read & Write N (No impact on the UE in idle mode) Not involved Not involved 1. The block of Ater interface must be configured. 2. If the BSC is configured to the integrated BMTC or A over IP is configured, the configuration does not support the operation. 3. If the block operation is applicable to only the ATERTS of the BM subrack. You are not allowed to perform the block operation from the primary BM subrack to the secondary BM subrack.
OPMODE Operation Mode BSC6900 BLK AE1T1(Mandatory) It is one key filed of identifying A interface timeslot status and indicates the alignment mode of A interface circuit. GBFD-111803A Interface Circuit Management Enumeration Type BYTSRANGE(BY TS RANGE), BYTSVALUE(BY TS VALUE) BYTSRANGE, BYTSVALUE None None None E1/T1 linkNone Read & Write N (No impact on the UE in idle mode) Not involved Not involved 1. The block of A interface must be configured. 2. If the BSC is configured to the integrated BMTC or A over IP is configured, the configuration does not support the operation. 3. If the block operation is applicable to only the AE1T1 of the BM subrack. You are not allowed to perform the block operation from the primary BM subrack to the secondary BM subrack.
OPNAME Operator Name BSC6900 ADD GCNNODE(Mandatory)ADD GCNOPERATOR(Mandatory)ADD GCELL(Optional)ADD GEXT2GCELL(Optional)ADD GEXT3GCELL(Optional)ADD NSE(Mandatory)ADD PCU(Mandatory)ADD SGSNNODE(Mandatory)ADD NRISGSNMAP(Mandatory) Name of the operator. This parameter uniquely identifies an operator. GBFD-118701RAN Sharing String Type None 0~255 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
OPTILAYER Assign Optimum Layer BSC6900 SET GCELLHOIUO(Optional) Channel assignment policies used when TCHs are assigned in an IUO cell: SysOpt: The system selects the preferentially-assigned service layer and assigns channels according to the measurement reports on SDCCHs; USubcell: preferentially assigns the TCHs on the underlay; OSubcell: preferentially assigns the TCHs on the overlay; NoPrefer: use the normal channel assignment algorithm to assign channels. GBFD-113201Concentric Cell Enumeration Type SysOpt(System optimization), OSubcell(Overlaid subcell), USubcell(Underlaid subcell), NoPrefer(No preference) SysOpt, OSubcell, USubcell, NoPrefer None None SysOpt Cell This parameter is valid only when "IUOTP" in "ADD GCELL" is set to Concentric_cell. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
OPTILEVTHRES Assign-optimum-level Threshold BSC6900 SET GCELLHOIUO(Optional) Preferentially assigns channels on the overlay when the uplink receive level on the SDCCH is no smaller than "Assign-optimum-level Threshold" and the TA is smaller than "TA Threshold of Assignment Pref"; otherwise, assigns channels on the underlay to ensure successful channel assignment. GBFD-113201Concentric Cell Interval Type 0~63 0~63 dB None 35 Cell This parameter is valid only when "IUOTP" in "ADD GCELL" is set to Concentric_cell and "OPTILAYER" is set to SysOpt. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
OPTITATHRES TA Threshold of Assignment Pref BSC6900 SET GCELLHOIUO(Optional) Preferentially assigns channels on the overlay when the uplink receive level on the SDCCH is no smaller than "Assign-optimum-level Threshold" and the TA is smaller than "TA Threshold of Assignment Pref"; otherwise, assigns channels on the underlay to ensure successful channel assignment. GBFD-113201Concentric Cell Interval Type 0~255 0~255 bit None 63 Cell This parameter is valid only when "IUOTP" in "ADD GCELL" is set to Concentric_cell and "OPTILAYER" is set to SysOpt. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
OPTL TRX Priority BSC6900 SET GTRXDEV(Optional) Channel assignment priority of the TRX. If this parameter is less, the TRX priority level is higher. Under the same conditions, the channels in a high-priority TRX are assigned before the channels in a low-priority TRX. GBFD-111005Enhanced Channel Assignment Algorithm Enumeration Type L0(Level0), L1(Level1), L2(Level2), L3(Level3), L4(Level4), L5(Level5), L6(Level6), L7(Level7) L0, L1, L2, L3, L4, L5, L6, L7 None None None TRX This parameter is valid only when "TRXPRIALLOW" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
OPTM Optical interface standard BSC6900 SET OPT(Optional) Optical interface standard None None Enumeration Type SDH, SONET SDH, SONET None None None Board None Read & Write Y BSC6900 Interrupt the service until negotiate successfully again. The setting of this parameter must be consistent with that on the peer.
OPTP Operation Type BSC6900 SWP BTSBRD(Mandatory) Type of the operation GBFD-111202O&M of BTS Enumeration Type MANUAL(MANUAL), FORCED(FORCED), CLEARALARMA(CLEARALARMA) MANUAL, FORCED, CLEARALARMA None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
OPTYPE Operate Type BSC6900 SET BTSFORBIDTS(Mandatory) The operation type can be "FORBID" or "RESTORE". GBFD-111202O&M of BTS Enumeration Type FORBID(Forbid), RESTORE(Restore) FORBID, RESTORE None None None BTS None Read & Write Y BTS Less than 5 minutes None
OPX OPX BSC6900 ADD GNRNC(Mandatory) Iur-g signaling point index of an internal RNC in GU mode MRFD-211402MBSC Load Balancing Interval Type 0~4 {0~4} None None None BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ORIPORT Originally E1/T1 Port No BSC6900 ADD BTSTOPCONFIG(Mandatory) If "Port Type" is set to "TOPEXTOUTPORT", this parameter determines the extended E1/T1 port through which the timeslots on the source E1/T1 port are used by other boards. If "Port Type" is set to "TOPEXTINPORT", this parameter is set to all 1s. MRFD-211501IP-Based 2G/3G Co-Transmission on Base Station Side Interval Type 0~7 0~7 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
OT Operation type BSC6900 LOD PATCH(Optional)CON PATCH(Optional) Operation type of the command. MRFD-210401BSC/RNC Software Management Enumeration Type One_touch(execute on all boards in all subracks), Step_by_Step One_touch, Step_by_Step None Step_by_Step Step_by_Step None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
OTHERFREQ Other Frequency BSC6900 ADD GCELLQUICKSETUP(Optional) Ordinary frequency. Multiple frequencies are separated by "&". For example, "22&33&44&55" are allocated to TRXs in ascending order. GBFD-510701Compact BTS Automatic Configuration and Planning String Type None 1~200 characters None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
OTOURECEIVETH OtoU HO Received Level Threshold BSC6900 SET GCELLHOIUO(Optional) One of the parameters that decide the underlay and overlay areas in an enhanced IUO cell. The underlay and overlay areas are decided by "OtoU HO Received Level Threshold", "UtoO HO Received Level Threshold", "RX_QUAL Threshold", "TA Threshold", and "TA Hysteresis" together. GBFD-113201Concentric Cell Interval Type 0~63 0~63 dB None 20 Cell This parameter is valid only when "IUOTP" in "ADD GCELL" is set to ENIUO. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
OUTASSOPTEN UL Subcell Assignment Optimization BSC6900 SET GCELLHOEDBPARA(Optional) Whether to assign channel requests initiated in the underlay subcell to the overlay or underlay subcells according to "UL Subcell General Overload Threshold". If the load of the underlay is higher than "UL Subcell General Overload Threshold", incoming calls in the underlay subcell will be preferentially assigned to the overlay subcell. GBFD-114402Enhanced Dual-Band Network Enumeration Type NO(No), YES(Yes)NO, YES None None YES Cell This parameter is valid only when "IUOTP" in "ADD GCELL" is set to EDB_cell. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
OUTBSCHOCLEARTIMER T8 BSC6900 SET GCELLTMR(Optional) The timer is used to set the time when the BSC waits for a handover success message after a handover command is sent in an outgoing BSC handover. If the timer expires, the outgoing BSC handover fails. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 500~60000 500~60000 ms None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved If this parameter is set to a greater value, too many channel resources are occupied and the congestion occurs.If this parameter is set to a smaller value, the handover success rate may fall.
OUTBSCHOCMDTIMER T7 BSC6900 SET GCELLTMR(Optional) The timer is used to set the time when the BSC waits for an HO REQ ACK message after a Handover Request message is reported in an outgoing BSC handover. If the timer expires, the outgoing BSC handover fails. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 500~60000 500~60000 ms None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved If this parameter is set to a greater value, too many channel resources are occupied and the congestion occurs.If this parameter is set to a smaller value, the handover success rate may fall.
OutBscLoadHoEn Inter BSC Load Information Allowed BSC6900 SET GCELLHOAD(Optional) Whether to use external 2G neighboring cells as the target cells of load handovers GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Enumeration Type NO(No), YES(Yes)NO, YES None None NO Cell This parameter is valid only when "LOADHOEN" in "SET GCELLHOBASIC" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
OUTGENOVERLDTHRED UL Subcell General Overload Threshold BSC6900 SET GCELLHOEDBPARA(Optional) When the load of the underlay subcell is higher than this parameter, some of the calls in the underlay subcell will be switched to the overlay subcell, and channels in the overlay subcell will be preferentially assigned to calls initiated in the underlay subcell as well. GBFD-114402Enhanced Dual-Band Network Interval Type 0~100 0~100 per cent None 80 Cell This parameter is valid only when "IUOTP" in "ADD GCELL" is set to EDB_cell. The following condition must be met: "OUTSERIOVERLDTHRED" > "OUTGENOVERLDTHRED" > "OUTLOWLOADTHRED". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
OUTHOPWROVERLOADTHRESHOLD Power Overload Threshold In Ho. Out BSC6900 SET GTRXDEV(Optional) Power overload threshold for triggering outgoing handover from the TRX under the prerequisite that the power amplifier of the TRX provides the maximum output power. If the power overload exceeds this parameter, the TRX triggers outgoing handover due to underpower. GBFD-111005Enhanced Channel Assignment Algorithm Interval Type 0~50 0~50 W None 15 TRX None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
OUTINNREXLEVTHRED Outgoing OL Subcell HO Level TH BSC6900 SET GCELLHOEDBPARA(Optional) Lower threshold of the overlay level during overlay-to-underlay handovers. When the receive level of an MS is higher than this threshold, the MS can be switched to the underlay subcell. GBFD-114402Enhanced Dual-Band Network Interval Type 0~63 0~63 dB None 25 Cell This parameter is valid only when "IUOTP" in "ADD GCELL" is set to EDB_cell. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
OUTLOADHOENABLE Load HO Allowed BSC6900 SET GCELLHOEDBPARA(Optional) Whether to switch some of the calls in the underlay subcell to the overlay when the load of the underlay is higher than this parameter GBFD-114402Enhanced Dual-Band Network Enumeration Type NO(No), YES(Yes)NO, YES None None YES Cell This parameter is valid only when "IUOTP" in "ADD GCELL" is set to EDB_cell. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
OUTLOADHOMODPERI MOD Step LEN of UL Load HO Period BSC6900 SET GCELLHOEDBPARA(Optional) If the underlay load is higher than "UL Subcell Serious Overload Threshold", the underlay-to-overlay handover period subtracts a value that equals this threshold from "UL Subcell Load Hierarchical HO Periods" every second. GBFD-114402Enhanced Dual-Band Network Interval Type 1~255 1~255 s None 1 Cell This parameter is valid only when "OUTLOADHOENABLE" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
OUTLOADHOPERIOD UL Subcell Load Hierarchical HO Periods BSC6900 SET GCELLHOEDBPARA(Optional) When the load of the underlay subcell exceeds "UL Subcell General Overload Threshold", all the calls that are using this cell as the serving cell generate handover requests at the same time, which will suddenly increase the load of the BSC and possibly cause congestion in the overlay subcell, thus causing the handovers to fail. To solve this problem, the BSC uses the hierarchical load handover algorithm to gradually switch some of the calls in the underlay subcell to the overlay subcell. This parameter indicates the duration of each handover level. GBFD-114402Enhanced Dual-Band Network Interval Type 1~255 1~255 s None 5 Cell This parameter is valid only when "OUTLOADHOENABLE" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
OUTLOADHOSTEP Step Length of UL Subcell Load HO BSC6900 SET GCELLHOEDBPARA(Optional) Level step during underlay-to-overlay hierarchical load handovers GBFD-114402Enhanced Dual-Band Network Interval Type 0~63 0~63 dB None 5 Cell This parameter is valid only when "OUTLOADHOENABLE" is set to YES and "IUOTP" in "ADD GCELL" is set to EDB_cell. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
OUTLOWLOADTHRED UL Subcell Lower Load Threshold BSC6900 SET GCELLHOEDBPARA(Optional) When the load of the underlay subcell is lower than this parameter, some of the calls in the overlay subcell will be switched to the underlay subcell, and channels in the underlay subcell will be preferentially assigned to channel requests initiated in the overlay subcell as well. GBFD-114402Enhanced Dual-Band Network Interval Type 0~100 0~100 per cent None 50 Cell This parameter is valid only when "IUOTP" in "ADD GCELL" is set to EDB_cell. The following condition must be met: "OUTGENOVERLDTHRED" > "OUTLOWLOADTHRED". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
OUTMASK Out BSC Mask BSC6900 ADD SEMILINK(Optional) Specify the timeslot mask out BSC. GBFD-114701Semi-Permanent Connection Bit Field Type TS0, TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10, TS11, TS12, TS13, TS14, TS15, TS16, TS17, TS18, TS19, TS20, TS21, TS22, TS23, TS24, TS25, TS26, TS27, TS28, TS29, TS30, TS31 TS0, TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10, TS11, TS12, TS13, TS14, TS15, TS16, TS17, TS18, TS19, TS20, TS21, TS22, TS23, TS24, TS25, TS26, TS27, TS28, TS29, TS30, TS31 None None None BSC None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
OUTPN Out BSC Port No. BSC6900 ADD SEMILINK(Mandatory) Out BSC Port No.. GBFD-114701Semi-Permanent Connection Interval Type 0~335 0~335 None None None BSC None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
OUTPORTNO DXX Out Port No. BSC6900 ADD DXXTSEXGRELATION(Mandatory) Number of the outgoing port of the DXX GBFD-111203O&M of BSC Interval Type 0~15 0~15 None None None BTS None Read & Write Y BTS Less than 5 minutes None
OUTPORTTS DXX Out Time Slot No. BSC6900 ADD DXXTSEXGRELATION(Mandatory) Number of the outgoing timeslot of the DXX GBFD-111203O&M of BSC Interval Type 0~31 0~31 None None None BTS None Read & Write Y BTS Less than 5 minutes None
OUTPUT0 Cannel 0 Digital Control Signal Level BSC6900 SET BTSDTMUBP(Optional) Level of the accessed alarm signal. If the alarm signal has high level, this parameter should be set to 0. Otherwise, it should be set to 1. GBFD-111202O&M of BTS Enumeration Type HIGH(High), LOW(Low) HIGH, LOW None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
OUTPUT1 Cannel 1 Digital Control Signal Level BSC6900 SET BTSDTMUBP(Optional) Level of the accessed alarm signal. If the alarm signal has high level, this parameter should be set to 0. Otherwise, it should be set to 1. GBFD-111202O&M of BTS Enumeration Type HIGH(High), LOW(Low) HIGH, LOW None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
OUTPUT2 Cannel 2 Digital Control Signal Level BSC6900 SET BTSDTMUBP(Optional) Level of the accessed alarm signal. If the alarm signal has high level, this parameter should be set to 0. Otherwise, it should be set to 1. GBFD-111202O&M of BTS Enumeration Type HIGH(High), LOW(Low) HIGH, LOW None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
OUTPUT3 Cannel 3 Digital Control Signal Level BSC6900 SET BTSDTMUBP(Optional) Level of the accessed alarm signal. If the alarm signal has high level, this parameter should be set to 0. Otherwise, it should be set to 1. GBFD-111202O&M of BTS Enumeration Type HIGH(High), LOW(Low) HIGH, LOW None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
OUTPUTPOWER Output Power BSC6900 ADD BTSLOCGRP(Mandatory) Output power of the location group. For a location group that consists of MRRU or GRRU boards, the default output power is 15W. For a location group that consists of DRRU boards, the default output power varies with frequency bands. That is, when the frequency band is 850M/900M, the default output power is 18W; when the frequency band is 1800M/1900M, the default output power is 15W. GBFD-510104Multi-site Cell Interval Type 10~2000 1~200 (step: 0.1) W None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
OUTPUTPOWER1 Output Power BSC6900 ADD BTSLOCGRP(Mandatory) Output power of the location group GBFD-510104Multi-site Cell Interval Type 300~530 30~53 (step: 0.1) dB None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
OUTPUTPOWERUNIT Output Power Unit BSC6900 ADD BTSLOCGRP(Optional) Output power unit of the location group GBFD-510104Multi-site Cell Enumeration Type 0_1dB(0.1dB), 0_1W(0.1W) 0.1dB, 0.1W None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
5/5/2014
Confidential Information of Huawei.
No Spreading without Permission
Page14of42
226347869.xls.ms_office Security Level:
OUTSERIOVERLDTHRED UL Subcell Serious Overload Threshold BSC6900 SET GCELLHOEDBPARA(Optional) When the load of the underlay subcell is higher than this parameter, the underlay-to-overlay load handover period subtracts a period that equals "Step Length of UL Subcell Load HO" from "UL Subcell Load Hierarchical HO Periods" every second, thus increasing the load handover speed. GBFD-114402Enhanced Dual-Band Network Interval Type 0~100 0~100 per cent None 90 Cell This parameter is valid only when "IUOTP" in "ADD GCELL" is set to EDB_cell. The following condition must be met: "OUTSERIOVERLDTHRED" > "OUTGENOVERLDTHRED" > "OUTLOWLOADTHRED". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
OUTSERVICEALM Cell Out-of-Service Alarm Switch BSC6900 SET GCELLSOFT(Optional) Whether to report a cell out-of-service alarm after a cell is out of service GBFD-111202O&M of BTS Enumeration Type NO(No), YES(Yes)NO, YES None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
OUTSN Out BSC Slot No. BSC6900 ADD SEMILINK(Mandatory) Out BSC Slot No.. GBFD-114701Semi-Permanent Connection Interval Type 0~27 0~27 None None None BSC None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
OUTSN Load Outlet Slot No. BSC6900 ADD ABISLOADSHARE(Mandatory) Slot No. of the Load Outlet interface board GBFD-111203O&M of BSC Interval Type 0~27 0~27 None None None None None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
OUTSRN Out BSC Subrack No. BSC6900 ADD SEMILINK(Mandatory) Out BSC Subrack No.. GBFD-114701Semi-Permanent Connection Interval Type 0~11 0~11 None None None BSC None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
OutSysLoadHoEn Allow Inter-RAT Load HO in Connect State BSC6900 SET GCELLHOINTERRATLDB(Optional) Whether to select a 3G neighboring cell as the destination cell for load handover in the connection state MRFD-211402MBSC Load Balancing Enumeration Type NO(No), YES(Yes)NO, YES None None NO Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
OUTSYSSERVHOREASSIGNEN Service Handover Reassign BSC6900 SET OTHSOFTPARA(Optional) When the Service Handover field in an ASS REQ message is 0, a direct retry process targeted at a 3G network is initiated. If the direct retry fails, the system decides whether to re-assign channels for the current call based on this parameter. GBFD-114321GSM/WCDMA Service Based Handover Enumeration Type NO(No), YES(Yes)NO, YES None None NO BSC6900This parameter is valid only when "OUTSYSSERVICEHOEN" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
OUTSYSSERVICEHOEN Service Based Handover Switch BSC6900 SET OTHSOFTPARA(Optional) If inter-system handover is enabled, the BSS decides whether to switch the current service to a 3G radio network according to the contents of the Service Handover cell in the ASS REQ or HO REQ message. GBFD-114321GSM/WCDMA Service Based Handover Enumeration Type CLOSE(Close), OPEN(Open) CLOSE, OPEN None None CLOSE BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
OUTTIMER Load Info Timeout Timer BSC6900 ADD GNRNC(Optional) Validity period for the BSC to keep the load information about a 3G neighboring cell on the RNC MRFD-211402MBSC Load Balancing Interval Type 1~60 {1~60} None 15 15 BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
OUTTSN Out BSC Start Timeslot No. BSC6900 ADD SEMILINK(Mandatory) Out BSC Start Timeslot No.. GBFD-114701Semi-Permanent Connection Interval Type 0~255 0~255 None None None BSC None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
OverCurAlmThdA ANT_A ALD Over Current Occur Threshold BSC6900 SET BTSRXUBP(Optional) Abnormally alarm raise threshold triggered by too heavy current of the ANT_A tributary antenna. When the actual current is higher than the configured value, the ALD Current Abnormally Alarm is triggered with the corresponding alarm tributary No. of 0. MRFD-210304Faulty Management Interval Type 10~3500 10~3500 mA 320 None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
OverCurAlmThdB ANT_B ALD Over Current Occur Threshold BSC6900 SET BTSRXUBP(Optional) Abnormally alarm raise threshold triggered by too heavy current of the ANT_B tributary antenna. When the actual current is higher than the configured value, the ALD Current Abnormally Alarm is triggered with the corresponding alarm tributary No. of 0. MRFD-210304Faulty Management Interval Type 10~3500 10~3500 mA 320 None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
OverCurAlmThdRET RET ALD Over Current Occur Threshold BSC6900 SET BTSRXUBP(Optional) Abnormally alarm raise threshold triggered by too heavy current of the RET tributary antenna. When the actual current is higher than the configured value, the ALD Current Abnormally Alarm is triggered with the corresponding alarm tributary No. of 0. MRFD-210304Faulty Management Interval Type 10~3500 10~3500 mA 185 185 BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
OverCurClrThdA ANT_A ALD Over Current Clear Threshold BSC6900 SET BTSRXUBP(Optional) Abnormally alarm clearance threshold triggered by too heavy current of the ANT_A tributary antenna. When the actual current is lower than the configured value, the ALD Current Abnormally Alarm clearance is triggered w MRFD-210304Faulty Management Interval Type 10~3500 10~3500 mA 280 None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
OverCurClrThdB ANT_B ALD Over Current Clear Threshold BSC6900 SET BTSRXUBP(Optional) Abnormally alarm clearance threshold triggered by too heavy current of the ANT_B tributary antenna. When the actual current is lower than the configured value, the ALD Current Abnormally Alarm clearance is triggered with the corresponding alarm tributary No. of 0. MRFD-210304Faulty Management Interval Type 10~3500 10~3500 mA 280 None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
OverCurClrThdRET RET ALD Over Current Clear Threshold BSC6900 SET BTSRXUBP(Optional) Abnormally alarm clearance threshold triggered by too heavy current of the RET tributary antenna. When the actual current is lower than the configured value, the ALD Current Abnormally Alarm clearance is triggered w MRFD-210304Faulty Management Interval Type 10~3500 10~3500 mA 155 155 BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
OverCurDurA A ALD Cur-Minor Alarm Over-Cur Duration BSC6900 SET BTSRXUBP(Optional) When the ANT_A tributary antenna current abnormally check mode is set to Mode 3, the parameter ALD Current Prompt Alarm is checked by periodical pulse. The periodical pulse consists of antenna over-current duration and normal current duration. This parameter is the ANT_A tributary antenna over-current duration. MRFD-210304Faulty Management Interval Type 100~10000 100~10000 ms None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
OverCurDurB B ALD Cur-Minor Alarm Over-Cur Duration BSC6900 SET BTSRXUBP(Optional) When the ANT_B tributary antenna current abnormally check mode is set to Mode 3, the parameter ALD Current Prompt Alarm is checked by periodical pulse. The periodical pulse consists of antenna over-current duration and normal current duration. This parameter is the ANT_B tributary antenna over-current duration. MRFD-210304Faulty Management Interval Type 100~10000 100~10000 ms None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
OVERLOADINTV Overload Indication Period BSC6900 SET GCELLCCCH(Optional) Interval for the BTS transmitting overload messages to the BSC. This parameter is used to control the reporting frequency of overload messages by the channel and TRX.The overload can be the TRX processor overload, downlink CCCH overload, or AGCH overload. For details, see GSM Rec. 08.58. GBFD-111003Radio Common Channel Management Interval Type 1~255 1~255 s None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
OVERTHD Derating TEMP Threshold BSC6900 SET BTSCABPARA(Optional) Temperature threshold of the derating function of the cabinet GBFD-111202O&M of BTS Interval Type 400~700 40~70 (step: 0.1) degree Celsius None 580 BTS The value of this parameter must be 8C greater than "Normal Work TEMP Threshold". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
P11 CPU Usage for Critical Paging FC BSC6900 SET BSCFCPARA(Optional) Threshold for critical flow control. When the usage of the CPU exceeds the threshold, the CPUS performs critical flow control for paging messages. GBFD-111705GSM Flow Control Interval Type 50~95 50~95 per cent None 90 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved If this parameter is set to a greater value, the CPU may be overloaded.If this parameter is set to a smaller value, the call loss rate is high.
P12 CPU Usage for Major Paging FC BSC6900 SET BSCFCPARA(Optional) Threshold for major flow control. When the usage of the CPU exceeds the threshold, the CPUS performs major flow control for paging messages. GBFD-111705GSM Flow Control Interval Type 50~95 50~95 per cent None 85 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved If this parameter is set to a greater value, the CPU may be overloaded.If this parameter is set to a smaller value, the call loss rate is high.
P13 CPU Usage for Minor Paging FC BSC6900 SET BSCFCPARA(Optional) Threshold for minor flow control. When the usage of the CPU exceeds the threshold, the CPUS performs minor flow control for paging messages. GBFD-111705GSM Flow Control Interval Type 50~95 50~95 per cent None 80 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved If this parameter is set to a greater value, the CPU may be overloaded.If this parameter is set to a smaller value, the call loss rate is high.
P14 CPU Usage for Slight Paging FC BSC6900 SET BSCFCPARA(Optional) Threshold for slight flow control. When the usage of the CPU exceeds the threshold, the CPUS performs slight flow control for paging messages. GBFD-111705GSM Flow Control Interval Type 50~95 50~95 per cent None 75 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved If this parameter is set to a greater value, the CPU may be overloaded.If this parameter is set to a smaller value, the call loss rate is high.
PaAdjVol PA Intelligent Adjust Voltage BSC6900 SET BTSOTHPARA(Optional) Whether to enable the multi-carrier intelligent voltage adjustment function. The intelligent voltage adjustment means to adjust the carrier transmitting frequency automatically according to the service power requirement. GBFD-111612Multi-Carrier Intelligent Voltage Regulation Enumeration Type NO(NO), YES(YES) NO, YES None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PACKASSDLSHIFT Move Packet Assignment Down to BTS BSC6900 SET GCELLPSOTHERPARA(Optional) Whether to support the function of moving the packet assignment down to the BTS. To improve the access speed of the MS, after the packet assignment is moved down to the BTS, the BSC reserves the uplink resources for the BTS. The BTS obtains the channel request of the MB by analyzing the downlink acknowledgement message sent by the MS. Then the BTS allocates the reserved uplink resources to the MS to move the packet assignment to the BTS. GBFD-119202Packet Assignment Taken Over by the BTS Enumeration Type NO(Not Support), YES(Support) NO, YES None None NO Cell None Read & Write Y Not involved Less than 5 minutes None
PAGECTHD Paging control threshold BSC6900 SET FCMSGQTHD(Optional) CPU usage threshold for paging flow control. When the average CPU usage of sliding windows reaches or exceeds the threshold, paging flow control is triggered. This parameter is valid only when "Board Class" is "XPU". WRFD-040100Flow Control Interval Type 30~100 30~100 per cent None 75 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PAGERTHD Paging restore threshold BSC6900 SET FCMSGQTHD(Optional) Packet queue usage threshold for recovery from paging flow control. When the average packet queue usage of sliding windows is lower than the threshold, paging flow control is stopped. This parameter is valid only when "Board Class" is "XPU". WRFD-040100Flow Control Interval Type 30~100 30~100 per cent None 65 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PAGESW Paging flow control switch BSC6900 SET FCSW(Optional) Whether to control paging flow WRFD-040100Flow Control Enumeration Type ON, OFF ON, OFF None None ON Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PAGINGAVGCAPACITYINPERIOD Average Paging Message Number In Period BSC6900 SET GCELLSOFT(Optional) Average number of paging messages allowed in a cell in a period GBFD-111705GSM Flow Control Interval Type 10~65535 10~65535 None None None Cell This parameter is valid when "ALLOWG2FLOWCTRALGL" in the "SET BSCFCPARA" command is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PAGINGLIFETIME BTS Paging Lifetime BSC6900 SET GCELLSOFT(Optional) Lifetime of a paging message in the queue of the BTS. The setting of this parameter must be consistent with the setting of timer T3113 in the core network; otherwise, the efficiency of paging scheduling over the Um interface is reduced. It is recommended that this parameter be set to a value one to two seconds shorter than timer T3113. The units of this parameter is 250ms. GBFD-110303Paging Interval Type 0~255 0~255 ms None 255 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PAGINGMAXCAPACITYINPERIOD MAX Paging Message Number In Period BSC6900 SET GCELLSOFT(Optional) Maximum number of paging messages allowed in a cell in a period GBFD-111705GSM Flow Control Interval Type 10~65535 10~65535 None None None Cell This parameter is valid when "ALLOWG2FLOWCTRALGL" in the "SET BSCFCPARA" command is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PAGTIMES Paging Times BSC6900 SET GCELLCCBASIC(Optional) For the BTS, this parameter is used to determine paging retransmissions. This parameter and the number of paging times configured in the MSC determine the number of paging retransmissions. The total number of paging times is approximately equal to the value of this parameter multiplied by the number of paging times configured in the MSC. GBFD-110303Paging Interval Type 1~8 1~8 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PANDEC PAN_DEC BSC6900 SET GCELLPSBASE(Optional) This parameter sets the PAN_DEC value used by the counter N3102 of the MS. When the timer T3182 of the MS expires, the N3102 reduces the value of PAN_DEC. 0: the value of PAN_DEC is 0; 7: the value of PAN_DEC is 7; Value N indicates that PAN_DEC is N; Not use: this parameter is not used. GBFD-114101GPRS Enumeration Type Pan_0(0), Pan_1(1), Pan_2(2), Pan_3(3), Pan_4(4), Pan_5(5), Pan_6(6), Pan_7(7), 255(not use) Pan_0, Pan_1, Pan_2, Pan_3, Pan_4, Pan_5, Pan_6, Pan_7, 255 None None Pan_1 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PANINC PAN_INC BSC6900 SET GCELLPSBASE(Optional) This parameter sets the PAN_INC value used by the counter N3102 of the MS. When receiving the packet uplink acknowledged or unacknowledged message sent by the network (V(S) or V(A) increases), the MS increases the count (PAN_INC) of the counter N3102. 0: the value of PAN_INC is 0; 7: the value of PAN_INC is 7; Value N indicates that PAN_DEC is N; Not use: this parameter is not used. GBFD-114101GPRS Enumeration Type Pan_0(0), Pan_1(1), Pan_2(2), Pan_3(3), Pan_4(4), Pan_5(5), Pan_6(6), Pan_7(7), 255(not use) Pan_0, Pan_1, Pan_2, Pan_3, Pan_4, Pan_5, Pan_6, Pan_7, 255 None None Pan_2 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PANMAX PAN_MAX BSC6900 SET GCELLPSBASE(Optional) RAN_MAX value, the maximum value of the N3102. 4: the value of PAN_MAX is 4; 32: the value of PAN_MAX is 32. Value N indicates that PAN_DEC is N; Not use: this parameter is not used. GBFD-114101GPRS Enumeration Type Pan_4(4), Pan_8(8), Pan_12(12), Pan_16(16), Pan_20(20), Pan_24(24), Pan_28(28), Pan_32(32), 255(not use) Pan_4, Pan_8, Pan_12, Pan_16, Pan_20, Pan_24, Pan_28, Pan_32, 255 None None Pan_20 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PAOPTILEVEL Priority of Shut Down TRX BSC6900 SET GTRXDEV(Optional) Priority level at which the BSC switches off the power amplifier of the TRX when the BSC is allowed to switch off the power amplifier of the TRX. If this parameter is less, the priority level of the power amplifier of the TRX is higher. GBFD-111602TRX Power Amplifier Intelligent Shutdown Enumeration Type L0(Level0), L1(Level1), L2(Level2), L3(Level3), L4(Level4), L5(Level5), L6(Level6), L7(Level7) L0, L1, L2, L3, L4, L5, L6, L7 None None None TRX This parameter is valid only when "BSCDynSwitchTrxPAAllow" in "SET BSCDSTPA","DYNOpenTrxPower" in "SET GCELLBASICPARA" and "CPS" are set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PatchNo Patch No. BSC6900 SET BTSAUTODLDACTINFO(Mandatory) Patch number of the TMU board software GBFD-111202O&M of BTS Interval Type 0~9999 0~9999 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PatchNo1 Patch Number BSC6900 SET BTSAUTODLDACTINFO(Mandatory) Patch number of the TMU board software GBFD-111202O&M of BTS Interval Type 0~99 0~99 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PATHCHK IP path check flag BSC6900 ADD IPPATH(Optional) IP path check flag None None Enumeration Type ENABLED(Enabled), DISABLED(Disabled) ENABLED, DISABLEDNone DISABLED DISABLED IP path None Read & Write Not involved Not involved Not involved This parameter cannot be modified.
PATHID IP path ID BSC6900 ADD IPPATH(Mandatory) IP path ID None None Interval Type 0~65535 0~65535 None None None IP path None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
PATHID IP path ID BSC6900 ADD IPMUX(Mandatory)ADD IPPATHBIND(Mandatory) IP path ID,Identifying an IP path. None None Interval Type 0~65535 0~65535 None None None IP path None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
PATHLOSS Path Loss of Different Frequency Band BSC6900 SET GCELLPWRBASIC(Optional) Transmission loss difference between radio frequencies on different bands GBFD-117602Active Power Control Interval Type 0~255 0~255, step:0.01 dB None 79 Cell This parameter is valid only when "PWRBCDALLOWD" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PATHLOSSHOEN Pathloss Ho. Enable BSC6900 SET GCELLHOBASIC(Optional) Whether to perform path loss-based sorting in a better cell handover algorithm GBFD-510501HUAWEI II Handover Enumeration Type NO(No), YES(Yes)NO, YES None None NO Cell This parameter is valid only when "HOCTRLSWITCH" is set to HOALGORITHM2. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PATHT IP path type BSC6900 ADD IPPATH(Optional) IP path type None None Enumeration Type QoS(QoS), BE(BE), AF11(AF11), AF12(AF12), AF13(AF13), AF21(AF21), AF22(AF22), AF23(AF23), AF31(AF31), AF32(AF32), AF33(AF33), AF41(AF41), AF42(AF42), AF43(AF43), EF(EF), LQ_QOS(LQ_QOS), LQ_BE(LQ_BE), LQ_AF11(LQ_AF11), LQ_AF12(LQ_AF12), LQ_AF13(LQ_AF13), LQ_AF21(LQ_AF21), LQ_AF22(LQ_AF22), LQ_AF23(LQ_AF23), LQ_AF31(LQ_AF31), LQ_AF32(LQ_AF32), LQ_AF33(LQ_AF33), LQ_AF41(LQ_AF41), LQ_AF42(LQ_AF42), LQ_AF43(LQ_AF43), LQ_EF(LQ_EF) QoS, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, QOS, LQ_BE, LQ_AF11, LQ_AF12, LQ_AF13, LQ_AF21, LQ_AF22, LQ_AF23, LQ_AF31, LQ_AF32, LQ_AF33, LQ_AF41, LQ_AF42, LQ_AF43, LQ_EF None None QoS IP path None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
PATTYPE Patch type BSC6900 LOD PATCH(Mandatory)CON PATCH(Mandatory) Patch type MRFD-210301Configuration Management Enumeration Type MAINCPU_PATCH(Main programme patch), DSP_PATCH(DSP programme patch) MAINCPU_PATCH, DSP_PATCH None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PB Pb BSC6900 SET GCELLPSPWPARA(Optional) BTS power attenuation on the measured PBCCH. GBFD-119115Power Control Enumeration Type DB0(0dB), DB2(-2dB), DB4(-4dB), DB6(-6dB), DB8(-8dB), DB10(-10dB), DB12(-12dB), DB14(-14dB), DB16(-16dB), DB18(-18dB), DB20(-20dB), DB22(-22dB), DB24(-24dB), DB26(-26dB), DB28(-28dB), DB30(-30dB) DB0, DB2, DB4, DB6, DB8, DB10, DB12, DB14, DB16, DB18, DB20, DB22, DB24, DB26, DB28, DB30 dB None DB2 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PBGTHOEN PBGT HO Allowed BSC6900 SET GCELLHOBASIC(Optional) Whether to use the PBGT handover algorithm. PBGT handovers are based on path loss. The PBGT handover algorithm searches in real time for cells that have lower path loss and meet certain system requirements, and decides whether to perform the handovers. To avoid ping-pong handovers, PBGT handovers can occur only on TCHs and among cells on a same layer and a same priority level. GBFD-110601HUAWEI I Handover Enumeration Type NO(No), YES(Yes)NO, YES None None YES Cell This parameter is valid only when "HOCTRLSWITCH" is set to HOALGORITHM1. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PBGTLAST PBGT Valid Time BSC6900 SET GCELLHOBASIC(Optional) The triggering of PBGT handovers must meet the P/N criteria, that is, when the condition for PBGT handovers is met for a consecutive P seconds during N seconds, a PBGT handover is triggered. This parameter corresponds to the P in the P/N criteria. GBFD-110601HUAWEI I Handover Interval Type 1~16 1~16 s None 2 Cell This parameter is valid only when "HOCTRLSWITCH" is set to HOALGORITHM1 and "PBGTHOEN" is set to YES. The following condition must be met: "PBGTSTAT" >= "PBGTLAST". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PBGTMARGIN PBGT HO Threshold BSC6900 ADD G2GNCELL(Optional) PBGT handovers to a neighboring cell are allowed only when the downlink level difference between the neighboring cell and the serving cell is larger than this parameter. When the value of this parameter is smaller than 64, handovers to a neighboring cell with a lower level than the current serving cell are allowed. GBFD-110601HUAWEI I Handover Interval Type 0~127 0~127 dB None In densely populated urban areas, the recommended value is 68; in the suburbs, the recommended value is 72. Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PBGTSTAT PBGT Watch Time BSC6900 SET GCELLHOBASIC(Optional) The triggering of PBGT handovers must meet the P/N criteria, that is, when the condition for PBGT handovers is met for a consecutive P seconds during N seconds, a PBGT handover is triggered. This parameter corresponds to the N in the P/N criteria. GBFD-110601HUAWEI I Handover Interval Type 1~16 1~16 s None 3 Cell This parameter is valid only when "HOCTRLSWITCH" is set to HOALGORITHM1 and "PBGTHOEN" is set to YES. The following condition must be met: "PBGTSTAT" >= "PBGTLAST". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PbMtnMsgReSend MAX Retrans Maintenance Msg on Pb-I BSC6900 SET OTHSOFTPARA(Optional) Maximum times for an external PCU to retransmit a PB interface maintenance message. When the PCU fails to receive a response to a PB interface maintenance message before the timer timeouts, it retransmits the PB interface maintenance message to the BSC. GBFD-114101GPRS Interval Type 0~65535 0~65535 None None 2 BSC6900This parameter is valid only when "TYPE" in "SET BSCPCUTYPE" is set to OUTER. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PCADJPERIOD PC Interval BSC6900 SET GCELLPWRBASIC(Optional) Minimum interval between two consecutive power control commands GBFD-110703Enhanced Power Control Algorithm Interval Type 1~15 1~15, step:480 for TCH and 470 for SDCCH ms None 3 Cell This parameter is valid when "PWRCTRLSW" in the "SET GCELLPWRBASIC" command is set to PWR2. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PCMEASCHAN PC_MEAS_CHAN BSC6900 SET GCELLPSPWPARA(Optional) Channel used for the measured receiving power. It is used to set the measured receiving power level of the channel and control the power of the uplink. GBFD-119115Power Control Enumeration Type bcch(bcch), pdch(pdch) bcch, pdch None None pdch Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PCU PCU No BSC6900 BLK PBCIC(Mandatory) It is one key filed of identifying Pb interface CIC status and indicates the PCU No. corresponding to the Pb interface CIC. GBFD-111203O&M of BSC Interval Type 0~31 0~31 None None None PBCIC None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
PCUINDEX PCU No. BSC6900 ADD PCU(Mandatory) PCU number, identifying a unique PCU number. GBFD-114101GPRS Interval Type 0~31 0~31 None None None BSC None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
PCUNO PCU No. BSC6900 ADD PBE1T1(Mandatory) Port No. of the E1/T1 of the Pb interface. GBFD-111203O&M of BSC Interval Type 0~31 0~31 None None None PBE1T1 None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
PCUNO PCU No. BSC6900 SET GCELLGPRS(Mandatory) Number of the PCU to which the current cell belongs. GBFD-114101GPRS Interval Type 0~255 0~255 None None None Cell This parameter is valid only when "GPRS" is set to SupportAsExtPcu. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PCUPREEMPTFLAG PCU Support PREEMPT_ABIS_LINK message BSC6900 SET BTSFLEXABISPARA(Optional) Whether the PCU supports the PREEMPT_ABIS_LINK message. If the BTS supports the FLEXABIS function, the CS service can preempt the timeslots on the Abis interface used by the PS service. After the preemption occurs, the BSC sends a PREEMPT_ABIS_LINK message to the PCU if the PCU can process the message. GBFD-111203O&M of BSC Enumeration Type NO(NO), YES(YES) NO, YES None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PDCHDWNLEV PDCH Downlink Multiplex Threshold BSC6900 SET GCELLPSCHM(Optional) PDCH downlink multiplex threshold, Indicating the maximum TBFs on the downlink PDCH (parameter value/10). GBFD-113101PDCH Dynamic Adjustment Interval Type 10~80 10~80 None None 80 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PDCHPWRSAVEN PDCH Power Saving Enable BSC6900 SET GCELLSOFT(Optional) Whether to enable power consumption reduction of the PDCH GBFD-111606Power Optimization Based on Channel Type Enumeration Type NO(No), YES(Yes)NO, YES None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PDCHREFORMING PDCH Reforming BSC6900 SET GCELLPSCHM(Optional) Whether to preempt the channels carrying the CS service when the channels for the PS service are insufficient "Level of Preempting Dynamic Channel" is set to "Preempt all dynamic TCHFs". This parameter must be used together with "Level of Preempting Dynamic Channel" in the following conditions:1. When "Level of Preempting Dynamic Channel" is set to Preempt all dynamic TCHFs and "PDCH Reforming" is set to "Yes", the channels for the CS service is released if the CS service fails be switched to another channel.2: When "Level of Preempting Dynamic Channel" is set to "Preempt all dynamic TCHFs" or "No preempt of CCHs" and "PDCH Reforming" is set to "Yes", the CS service is switched to the original channel if the CS service fails to be switched to another channel. GBFD-113101PDCH Dynamic Adjustment Enumeration Type NO(NO), YES(YES) NO, YES None None NO Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PDCHUPLEV PDCH Uplink Multiplex Threshold BSC6900 SET GCELLPSCHM(Optional) PDCH uplink multiplex threshold, indicating the maximum TBFs on the uplink PDCH (parameter value/10). GBFD-113101PDCH Dynamic Adjustment Interval Type 10~70 10~70 None None 70 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PDTMRVALUE PENDING timer BSC6900 ADD M3LKS(Optional) Pending timer of the M3UA link set. None None Interval Type 1~10 1~10 s 5 5 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PeerBSCID Peer BSC ID BSC6900 SET GBSCREDGRP(Mandatory) Peer BSC identity. GBFD-113725BSC Node Redundancy Interval Type 0~65534 0~65534 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PEERBSCID Peer BSC ID BSC6900 SET BTSIP(Mandatory) ID of the peer BSC GBFD-118601Abis over IP Interval Type 0~65534 0~65534 None None None BTS None Read & Write Y BTS Less than 15 minutes None
PEERBSCIP Peer BSC IP BSC6900 SET BTSIP(Mandatory) IP address of the peer BSC on the home BSC side GBFD-118601Abis over IP IP Address Type None 0.0.0.0~255.255.255.255 None None None BTS None Read & Write Y BTS Less than 5 minutes None
PEERBSCMASK Peer BSC Mask BSC6900 SET BTSIP(Mandatory) IP subnet mask of the peer BSC port GBFD-118601Abis over IP IP Address Type None 0.0.0.0~255.255.255.255 None None None BTS None Read & Write Y BTS Less than 5 minutes None
PEERBTSID Peer BTS ID BSC6900 SET BTSIP(Mandatory) Identifier of the peer BTS on the home BSC side GBFD-118601Abis over IP Interval Type 0~2047 0~2047 None None None BTS None Read & Write Y BTS Less than 5 minutes None
PEERIP Peer IP address BSC6900 ADD PPPLNK(Mandatory) Peer IP address. GBFD-118611GBFD-118622 Abis IP over E1/T1A IP over E1/T1 IP Address Type None 0.0.0.0~255.255.255.255 None None None BSC6900None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
PEERIP Peer IP address BSC6900 ADD MPGRP(Mandatory) Peer IP address of the MP group GBFD-118611GBFD-118622 Abis IP over E1/T1A IP over E1/T1 IP Address Type None 0.0.0.0~255.255.255.255 None None None MP groupNone Read & Write N (No impact on the UE in idle mode) Not involved Not involved The local IP address and peer IP must be configured in the same network segment. The peer IP address cannot be the same with the local IP address of the BSC.
PEERIP Peer IP address BSC6900 STR IPCHK(Mandatory) Detects the IP address of the gateway GBFD-118609IP Fault Detection Based on BFD IP Address Type None 0.0.0.0~255.255.255.255 None None None None None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
PEERIP Peer IP address BSC6900 ADD BTSPPPLNK(Mandatory)ADD BTSMPGRP(Mandatory) IP address of the peer GBFD-118611Abis IP over E1/T1 IP Address Type None 0.0.0.0.~255.255.255.255 None None None BTS The peer IP address and the local IP address specified by "Local IP address" must be on the same network segment. Read & Write Y PPP link Less than 5 minutes None
PEERIP1 First destination IP address BSC6900 ADD SCTPLNK(Mandatory) First destination IP address. The invalid value is 0. None None IP Address Type None 0.0.0.0~255.255.255.255 None None None SCTP linkNone Read & Write Y SCTP link The services are interrupted until the SCTP link is working normally. The both end address of the SCTP is the parameter for the interconnection. The value can be modified after the negotiation with the peer system.
PEERIP2 Second destination IP address BSC6900 ADD SCTPLNK(Optional) Second destination IP address. The invalid value is 0. None None IP Address Type None 0.0.0.0~255.255.255.255 None None None SCTP linkNone Read & Write Y SCTP link The services are interrupted until the SCTP link is working normally. The both end address of the SCTP is the parameter for the interconnection. The value can be modified after the negotiation with the peer system.
PEERIPADDR Peer IP address BSC6900 ADD IPPATH(Mandatory) The peer IP address should not be the same as the local address. None None IP Address Type None 0.0.0.0~255.255.255.255 None None None IP path "IPADDR" and "PEERIPADDR" in "ADD IPPATH" must be at one network segment;("IPADDR","PEERIPADDR","PEERMASK" in "ADD IPPATH") conflicts with other IPPATH whose type is IUPS. Read & Write Not involved Not involved Not involved The parameter cannot be modified.
PEERMASK Peer subnet mask BSC6900 ADD IPPATH(Optional) Subnet mask of the peer IP None None IP Address Type None 0.0.0.0~255.255.255.255 None 255.255.255.255 255.255.255.255 IP path ("IPADDR","PEERIPADDR","PEERMASK" in "ADD IPPATH") conflicts with other IPPATH whose type is IUPS. Read & Write Not involved Not involved Not involved The parameter cannot be modified.
PEERPN Destination SCTP port No. BSC6900 ADD SCTPLNK(Mandatory) Destination SCTP port No.. None None Interval Type 1024~65535 1024~65535 None None None SCTP linkNone Read & Write Y SCTP link The services are interrupted until the SCTP link is working normally. The SCTP port number is the parameter for the negotiation. The value can be modified after the negotiation with the peer system.
PEERVERSION Peer Version BSC6900 SET BTSLOADCTRL(Mandatory) Peer Software Version GBFD-111202O&M of BTS String Type None 1~63 characters None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PENALTYEN Penalty Allowed BSC6900 SET GCELLHOCTRL(Optional) Whether to punish the target cell when a handover fails or to punish the current serving cell when a handover is of more TA or bad quality. After a handover fails due to congestion of the target cell, the system needs to punish the target cell to prevent the MS from attempting to switch to the target cell again. Ping-pong handovers can easily occur when handovers are of more TA or bad quality. In these cases, the system needs to punish the current serving cells. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Enumeration Type NO(No), YES(Yes)NO, YES None None YES Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PENALTYLASTTM Cell Penalty Duration BSC6900 SET GCELLNC2PARA(Optional) Penalty duration for cell reselection. Cell penalty can be performed only in this duration. When this parameter is set to a greater value, the MS cannot reselect a cell in longer time in the case of reselection failure or reselection due to load. The penalty timer is shorter when this parameter is set to a smaller value. GBFD-116201Network-Controlled Cell Reselection (NC2) Interval Type 0~255 0~255 s None 10 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PENALTYRXLEV Cell Penalty Level BSC6900 SET GCELLNC2PARA(Optional) Penalty level of the target cell when the cell reselection failure message is received or the cell starts the load reselection. This parameter is valid only in the cell penalty duration. GBFD-116201Network-Controlled Cell Reselection (NC2) Interval Type 0~63 0~63 None None 30 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PENALTYTIMER CfgPenaltyTimer BSC6900 SET GCELLHOFITPEN(Optional) Timer of penalty on a neighboring cell when a handover fails due to faults of data configration. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 0~255 0~255 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PERIOD Ping Check Period BSC6900 ADD IPPATH(Optional) Ping check period of IP Path None None Interval Type 1~60 1~60 s 5 5 IP path When the value of "PATHCHK" in "ADD IPPATH" is set to ENABLED, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved When the network status is poor, the check period should not be too small. Otherwise, the path state is affected.
PERIOD Measurement Period BSC6900 STR NCS(Mandatory) Measurement period for each frequency group GBFD-5109012G/3G Neighboring Cell Automatic Optimization Interval Type 1~48 1~48, step:15 min None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PFC Protocal field compress BSC6900 ADD PPPLNK(Optional) Compression flag of the PPP link protocol domain GBFD-118611GBFD-118622 Abis IP over E1/T1A IP over E1/T1 Enumeration Type Disable(Disable), Enable(Enable) Disable, Enable None Enable Enable PPP link None Read & Write Y PPP link Interrupt the service until negotiate successfully again. Negotiation fails if this parameter is modified.
PFC Protocol field compress BSC6900 ADD MPLNK(Optional) Compression flag of the PPP link protocol domain GBFD-118611GBFD-118622 Abis IP over E1/T1A IP over E1/T1 Enumeration Type Disable(Disable), Enable(Enable) Disable, Enable None Enable Enable MP link None Read & Write Y BSC6900 Interrupt the service until negotiate successfully again. Negotiation fails if this parameter is modified.
PFC Protocol field compress BSC6900 ADD BTSPPPLNK(Optional)ADD BTSMPLNK(Optional) Whether to compress the protocol field of the PPP link GBFD-118611Abis IP over E1/T1 Enumeration Type Disable, Enable Disable, Enable None Enable Enable BTS None Read & Write Y PPP link Less than 5 minutes None
PFCSUP PFC Support BSC6900 ADD NSE(Optional) Whether to support packet flow context (PFC). The PFC flow is used to control the QoS of the packet service of the MS. GBFD-119901Streaming QoS(GBR) Enumeration Type NO(No Support), YES(Support) NO, YES None NO NO NSE None Read & Write Y NSE Less than 5 minutes The SIGBVC must be reset after this switch is turned on. The BSC supports the PFC when the SGSN supports the PFC.
PGCLASSIFINGALLOWED Paging Message Classifying Allowed BSC6900 SET BSCFCPARA(Optional) Whether to support the paging message classification function GBFD-111705GSM Flow Control Interval Type 0~2 0~2 None None 2 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PGMAXMSGNUMINPERIOD Max Paging Message Num in Period BSC6900 SET BSCFCPARA(Optional) Maximum number of paging messages that the BSC can process over the A interface within a measurement period GBFD-111705GSM Flow Control Interval Type 10~1000 10~1000 None None 660 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved If this parameter is set to a greater value, more paging messages are processed. When the BSC is overloaded, the control on the arrival rate of paging messages does not take effect. If this parameter is set to a smaller value, some paging messages that can be processed by the BSC are discarded, thus affecting the call success rate.If the value of Pg State Period(ms) is changed, you need to change the value of this parameter accordingly.
PGSTATPERIOD Paging Statistical Period BSC6900 SET BSCFCPARA(Optional) Measurement period for calculating the arrival rate of paging messages GBFD-111705GSM Flow Control Interval Type 100~600000 100~600000 ms None 1000 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved If this parameter is set to a smaller value, the control of the arrival rate of paging messages is sensitive. If this parameter is set to a greater value, the control is insensitive.
PHB Per-Hop Behavior BSC6900 SET PHBMAP(Mandatory) Value of the per-hop behavior (PHB) None None Enumeration Type BE(BE), AF11(AF11), AF12(AF12), AF13(AF13), AF21(AF21), AF22(AF22), AF23(AF23), AF31(AF31), AF32(AF32), AF33(AF33), AF41(AF41), AF42(AF42), AF43(AF43), EF(EF) BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF None None None Board 1.The phb of the traffic's transmission path is determined like this: if the phb of this transmission path is QOS, use the traffic's phb from TRMMAP; if the phb of this transmission path is BE,AF11,AF12,AF13,AF21,AF22,AF23,AF31,AF32,AF33,AF41,AF42,AF43,EF, use the phb of transmission path. Read & Write Not involved Not involved Not involved The parameter cannot be modified.
PHB PHB BSC6900 ADD IPMUX(Mandatory) PHB type of the IPMUX to be enabled GBFD-118604GBFD-118610 Abis MUXUDP MUX for A Transmission Bit Field Type BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, , AF43, EF None None None IP Path None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The adjacent node ID must be configured.
PI Cell Reselect Parameters Indication BSC6900 SET GCELLIDLEBASIC(Optional) Cell Reselect Parameters Indication (PI), sent on the broadcast channel, indicates whether "Cell reselect offset", "Cell reselect temporary offset" in the "SET GCELLIDLEAD" command, and "Cell reselect penalty time" are used. GBFD-110402Basic Cell Re-selection Enumeration Type NO(No), YES(Yes)NO, YES None None None Cell None Read & Write N (Impact on the UE in idle mode) Not involved Not involved None
PKPEnableSta Private Key Password Enabled State BSC6900 SET CERTFILE(Optional) Whether to enable the private key passwordDISABLE: indicating that the private key password is disabledENABLE: indicating that the private key password is enabled MRFD-210305Security Management Enumeration Type DISABLE(Disable), ENABLE(Enable) DISABLE, ENABLE None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PKTCOUNT PKT Count BSC6900 STR ETHOAMLOOPTST(Optional) Indicates the number of the packets for remote loopback test of the OAM in the Ethernet GBFD-118630Ethernet OAM Interval Type 5~64 5~64 None 10 10 BSC6900None Read & Write Y Ethernet port The loopback keeps interrupting the services until the loopback is cancelled. None
PKTLEN PKT Size[Byte] BSC6900 STR ETHOAMLOOPTST(Optional) Indicates the length of the packets for the remote loopback test of the OAM in the Ethernet GBFD-118630Ethernet OAM Interval Type 64~1024 64~1024 byte 128 128 BSC6900None Read & Write Y Ethernet port The loopback keeps interrupting the services until the loopback is cancelled. None
PKTLEN Packet Length BSC6900 STR FRPORTLOOP(Mandatory) Loopback packet length. GBFD-111203O&M of BSC Interval Type 2~1500 2~1500 byte None None BC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PKTLENTHRES MUX Packet Length Threshold BSC6900 ADD BTSABISMUXFLOW(Optional) Multiplexing packet length threshold. The length of the multiplexed packet must not exceed the multiplexing packet length threshold. If the length of the multiplexed packet exceeds the multiplexing packet length threshold, the packet is transferred without being added with new subframes. The multiplexing packet length threshold refers to the payload, excluding the IP/UDP header. GBFD-118604Abis MUX Interval Type 24~1031 24~1031 byte 1000 1000 BTS This parameter must meet the following requirements: The sum of the value of "MUX Sub Frame Threshold" and 8 must be smaller than the value of this parameter. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PKTSI PACKET SI BSC6900 SET GCELLGPRS(Optional) Whether the cell supports the PACKET SI STATUS flow. In the PACKET SI STATUS flow, the MS sends the Packet PSI/SI Status message to indicate that the MS has stored the system message. The network side sends the Packet Serving Cell Data message to notify the MS of the system message not stored. GBFD-119801Packet SI Status Enumeration Type NO(No), YES(Yes)NO, YES None None None Cell This parameter is valid only when "GPRS" is set to SupportAsInnPcu or SupportAsExtPcu. Read & Write Y Cell Less than 5 minutes None
PKTSIZE Size of packet BSC6900 PING IP(Optional) Indicates the size of the PING packet, neither IP header nor ICMP header is included. None None Interval Type 20~1500 20~1500 byte 56 56 Ethernet port None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
PKTSIZE PKT Size BSC6900 PING MAC(Optional)PING BTSCFM(Optional) Sent packet size GBFD-118630Ethernet OAM Interval Type 95~512 95~512 byte 128 128 Ethernet port None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PL1 Persistence Level 1 BSC6900 SET GCELLPRACH(Optional) Persistence level 1 of the radio access priority. During MS access, the access priority of the MS is set. If the priority of the MS is higher than the access priority of the MS, the cell allows the access of the MS. Otherwise, the cell rejects the access of the MS. The value "no use" indicates this parameter is not used. GBFD-119110Access Enumeration Type 0_level(0_level), 1_level(1_level), 2_level(2_level), 3_level(3_level), 4_level(4_level), 5_level(5_level), 6_level(6_level), 7_level(7_level), 8_level(8_level), 9_level(9_level), 10_level(10_level), 11_level(11_level), 12_level(12_level), 13_level(13_level), 14_level(14_level), 16_level(16_level), nouse(no use) 0_level, 1_level, 2_level, 3_level, 4_level, 5_level, 6_level, 7_level, 8_level, 9_level, 10_level, 11_level, 12_level, 13_level, 14_level, 16_level, no use None None 12_level Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PL16QAM 16QAM Transmitter Power Reduce Level BSC6900 SET GTRXDEV(Optional) 16QAM power attenuation level of all carriers except timeslot 7 on the BCCH TRX. This parameter is required because the EDGE TRXs must use the power lower than the average GMSK power to transmit the 16QAM signals within the spectrum specifications. GBFD-114201EGPRS Interval Type 0~50 0~50, step:0.2 dB None 0 TRX None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter is valid for the EDGE TRX only.
PL2 Persistence Level 2 BSC6900 SET GCELLPRACH(Optional) Persistence level 2 of the radio access priority. During MS access, the access priority of the MS is set. If the priority of the MS is higher than the access priority of the MS, the cell allows the access of the MS. Otherwise, the cell rejects the access of the MS. The value "no use" indicates this parameter is not used. GBFD-119110Access Enumeration Type 0_level(0_level), 1_level(1_level), 2_level(2_level), 3_level(3_level), 4_level(4_level), 5_level(5_level), 6_level(6_level), 7_level(7_level), 8_level(8_level), 9_level(9_level), 10_level(10_level), 11_level(11_level), 12_level(12_level), 13_level(13_level), 14_level(14_level), 16_level(16_level), nouse(no use) 0_level, 1_level, 2_level, 3_level, 4_level, 5_level, 6_level, 7_level, 8_level, 9_level, 10_level, 11_level, 12_level, 13_level, 14_level, 16_level, no use None None 13_level Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PL3 Persistence Level 3 BSC6900 SET GCELLPRACH(Optional) Persistence level 3 of the radio access priority. During MS access, the access priority of the MS is set. If the priority of the MS is higher than the access priority of the MS, the cell allows the access of the MS. Otherwise, the cell rejects the access of the MS. The value "no use" indicates this parameter is not used. GBFD-119110Access Enumeration Type 0_level(0_level), 1_level(1_level), 2_level(2_level), 3_level(3_level), 4_level(4_level), 5_level(5_level), 6_level(6_level), 7_level(7_level), 8_level(8_level), 9_level(9_level), 10_level(10_level), 11_level(11_level), 12_level(12_level), 13_level(13_level), 14_level(14_level), 16_level(16_level), nouse(no use) 0_level, 1_level, 2_level, 3_level, 4_level, 5_level, 6_level, 7_level, 8_level, 9_level, 10_level, 11_level, 12_level, 13_level, 14_level, 16_level, no use None None 14_level Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PL32QAM 32QAM Transmitter Power Reduce Level BSC6900 SET GTRXDEV(Optional) 32QAM power attenuation level of all carriers except timeslot 7 on the BCCH TRX. This parameter is required because the EDGE TRXs must use the power lower than the average GMSK power to transmit the 32QAM signals within the spectrum specifications. GBFD-114201EGPRS Interval Type 0~50 0~50, step:0.2 dB None 0 TRX None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter is valid for the EDGE TRX only.
PL4 Persistence Level 4 BSC6900 SET GCELLPRACH(Optional) Persistence level 4 of the radio access priority. During MS access, the access priority of the MS is set. If the priority of the MS is higher than the access priority of the MS, the cell allows the access of the MS. Otherwise, the cell rejects the access of the MS. The value "no use" indicates this parameter is not used. GBFD-119110Access Enumeration Type 0_level(0_level), 1_level(1_level), 2_level(2_level), 3_level(3_level), 4_level(4_level), 5_level(5_level), 6_level(6_level), 7_level(7_level), 8_level(8_level), 9_level(9_level), 10_level(10_level), 11_level(11_level), 12_level(12_level), 13_level(13_level), 14_level(14_level), 16_level(16_level), nouse(no use) 0_level, 1_level, 2_level, 3_level, 4_level, 5_level, 6_level, 7_level, 8_level, 9_level, 10_level, 11_level, 12_level, 13_level, 14_level, 16_level, no use None None 16_level Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PL8PSK TRX 8PSK Level BSC6900 SET GTRXDEV(Optional) Level at which the power in the EDGE TRX is decreased. The power can be decreased at 50 levels. At each level, the power is decreased by 0.2 dB. To meet spectrum requirements, an EDGE transceiver transmits 8PSK signals at a power lower than the average power for GMSK modulation. GBFD-114201EGPRS Interval Type 0~50 0~50 None None None TRX None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter is valid only for EDGE TRXs and is invalid for ordinary TRXs.
PLPRD Packet lost measure period [100ms] BSC6900 ADD IPLOGICPORT(Optional) Statistics period of the packet drop ratio. This parameter indicates the period for collecting the statistics information about the packet drop ratio. Note that the unit of this parameter is 100 milliseconds. The actual delay statistics period is the value of this parameter multiplied by 100 milliseconds. None None Interval Type 1~100 100~10000, step:100 ms 10 10 IP logical port None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PLTH Packet discard threshold[0.001] BSC6900 ADD IPLOGICPORT(Optional) Packet drop ratio threshold for speed reduction. When the packet drop ratio exceeds the value of this parameter, the rate of the logical port is reduced. Note that the unit of this parameter is a thousand to one. None None Interval Type 0~1000 0~1, step:0.001 None 30 30 IP logical port None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PLYPOINT Play Point BSC6900 SET TCPLYVOICE(Mandatory) Point at which to play sound GBFD-111203O&M of BSC Enumeration Type A(A Interface), ABIS(Abis Interface) A, ABIS None None None Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PLYSWITCH Play Switch BSC6900 SET TCPLYVOICE(Mandatory) Whether to enable sound playing GBFD-111203O&M of BSC Enumeration Type CLOSE(Close), OPEN(Open) CLOSE, OPEN None None None Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved If "Play switch" is set, the normal calls may be affected.
PLYTIME Play Time BSC6900 SET TCPLYVOICE(Optional) Duration of sound playing. If this parameter is set to 0, the sound is played repeatedly. If this parameter exceeds the duration of the record file, the void sound is played for the exceeding part. GBFD-111203O&M of BSC Interval Type 0~600 0~600 s None None Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PMCTHD Performance monitor control threshold BSC6900 SET FCCPUTHD(Optional) CPU usage threshold for performance monitoring. When the average CPU usage of sliding windows reaches or exceeds the threshold, performance monitoring is triggered. This parameter is valid only when "Board Class" is "XPU" or "SCU". WRFD-040100Flow Control Interval Type 30~100 30~100 per cent None 60 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PMCTHD Performance monitor control threshold BSC6900 SET FCMSGQTHD(Optional) Packet queue usage threshold for performance monitoring. When the average packet queue usage of sliding windows reaches or exceeds the threshold, performance monitoring is triggered. This parameter is valid only when "Board Class" is "XPU" or "SCU". WRFD-040100Flow Control Interval Type 30~100 30~100 per cent None 67 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PMI Interval for Sending Cell Paging Package BSC6900 SET GCELLSOFT(Mandatory) Interval for sending cell paging group packets when Paging Messages Optimize at Abis Interface is enabled GBFD-110303Paging Interval Type 1~8 1~8, step: 50 ms None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PMNUM Number of Cell Pagings in One Package BSC6900 SET GCELLSOFT(Mandatory) Number of cell paging group packets when Paging Messages Optimize at Abis Interface is enabled GBFD-110303Paging Interval Type 2~15 2~15 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PMOAFLAG Cell Paging Package Switch BSC6900 SET GCELLSOFT(Optional) Whether to enable Paging Messages Optimize at Abis Interface GBFD-110303Paging Enumeration Type CLOSE(Forced turn-off), OPEN(Forced turn-on), AUTO(Self-adaptive) CLOSE, OPEN, AUTONone None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PMRTHD Performance monitor restore threshold BSC6900 SET FCCPUTHD(Optional) CPU usage threshold for recovery from performance monitoring. When the average CPU usage of sliding windows is lower than the threshold, performance monitoring is stopped. This parameter is valid only when "Board Class" is "XPU" or "SCU". WRFD-040100Flow Control Interval Type 30~100 30~100 per cent None 50 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PMRTHD Performance monitor restore threshold BSC6900 SET FCMSGQTHD(Optional) Packet queue usage threshold for recovery from performance monitoring. When the packet queue usage of sliding windows is lower than the threshold, performance monitoring is stopped. This parameter is valid only when "Board Class" is "XPU" or "SCU". WRFD-040100Flow Control Interval Type 30~100 30~100 per cent None 62 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PMSW Performance monitoring flow control switch BSC6900 SET FCSW(Optional) Whether to monitor the RRM performance WRFD-040100Flow Control Enumeration Type ON, OFF ON, OFF None None ON Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PN Port No. BSC6900 SET SCUPORT(Optional) Number of the port MRFD-210301Configuration Management Interval Type 0~11 0~11 None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PN Port No. BSC6900 SET ALMPORT(Mandatory) Port No. of environment alarm MRFD-210304Faulty Management Interval Type 1~32 1~32 None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PN Port No. BSC6900 SET XPUPORT(Optional) Port No. of the XPUa/XPUb/SPUa/SPUb board. If you do not specify this parameter, all ports of the XPUa board are queried. MRFD-210301Configuration Management Interval Type 0~3 0~3 None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PN Port No BSC6900 ADD ATERE1T1(Mandatory) E1T1 port number of the Ater interface E1 mode: 0~31 (EIU), 0~62(OIU), 0~251(POUc). T1 mode: 0~31(EIU), 0~83(OIU), 0~335(POUc). GBFD-111801Ater Interface 4:1 Multiplexing Interval Type 0~335 0~335 None None None E1/T1 linkNone Read & Write Not involved Not involved Not involved The parameter cannot be modified.
PN Port No. BSC6900 ADD PBE1T1(Mandatory) Port No. of the E1/T1 of the Pb interface. GBFD-111203O&M of BSC Interval Type 0~335 0~335 None None None PBE1T1 None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
PN Port No BSC6900 ADD AE1T1(Mandatory)BLK AE1T1(Mandatory) Port number GBFD-111803A Interface Circuit Management Interval Type 0~335 0~335 None None None E1/T1 linkNone Read & Write Not involved Not involved Not involved The parameter cannot be modified.
PN BM Port No BSC6900 BLK ATERE1T1(Mandatory) It is one key field of identifying the block of the Ater timeslot and indicates the port No. of the Ater interface timeslot. None None Interval Type 0~335 0~335 None None None E1/T1 linkNone Read & Write N (No impact on the UE in idle mode) Not involved Not involved 1. The block of Ater interface must be configured. 2. If the BSC is configured to the integrated BMTC or A over IP is configured, the configuration does not support the operation. 3. If the block operation is applicable to only the ATERTS of the BM subrack. You are not allowed to perform the block operation from the primary BM subrack to the secondary BM subrack.
PN Port No. BSC6900 ADD OBJALMSHLD(Mandatory) Number of the port where the alarm is generated MRFD-210304Faulty Management Interval Type 0~335 0~335 None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PN Port No. BSC6900 SET MSPCMD(Mandatory)SET MSP(Mandatory) Indicates the port number for running this command.OIUa: 0; AOUa/POUa: 0~1; UOIa(ATM)/UOIa(IP)/AOUc/POUc: 0~3; UOIc:0~7 None None Interval Type 0~7 0~7 None None None Ethernet port None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
PN Port No. BSC6900 SET E1T1LOP(Optional) E1/T1 port number None None Interval Type 0~335 0~31(AEUa/PEUa/EIUa), 0~62(E1 of OIUa), 0~83(T1 of OIUa), 0~125(E1 of AOUa/POUa), 0~167(T1 of AOUa/POUa), 0~251(E1 of AOUc/POUc), 0~335(T1 of AOUc/POUc) None None None E1/T1 port None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PN Port No. BSC6900 LOP E1T1(Optional) E1/T1 port number None None Interval Type 0~335 0~31(AEUa/PEUa/EIUa), 0~62(E1 of OIUa), 0~83(T1 of OIUa), 0~125(E1 of AOUa/POUa), 0~167(T1 of AOUa/POUa), 0~251(E1 of AOUc/POUc), 0~335(T1 of AOUc/POUc) None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PN Port No. BSC6900 STR E1T1TST(Optional) E1/T1 port number None None Interval Type 0~335 0~31(AEUa/PEUa/EIUa), 0~62(E1 of OIUa), 0~83(T1 of OIUa), 0~125(E1 of AOUa/POUa), 0~167(T1 of AOUa/POUa), 0~251(E1 of AOUc/POUc), 0~335(T1 of AOUc/POUc) None None None E1/T1 port None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
PN Port No. BSC6900 SET OPTLOP(Mandatory) Indicates the port number for running this command.OIUa: 0; AOUa/POUa: 0~1; UOIa(ATM)/UOIa(IP)/AOUc/POUc: 0~3; UOIc: 0~7 None None Interval Type 0~7 0~7 None None None Loopback optical port None Read & Write N (No impact on the UE in idle mode) Not involved Not involved When the loopback type is changed to REMOTE_LOOP or LOCAL_LOOP, the service is affected. The service becomes normal when the loopback test is canceled. When the loopback type is set to LOCAL_LOOP, you cannot directly change it to REMOTE_LOOP. You must change it to NO_LOOP first and then to REMOTE_LOOP. You can change the loopback type from REMOTE_LOOP to LOCAL_LOOP in the similar way.
PN Port No. BSC6900 SWP ETHPORT(Mandatory) Port number GBFD-111701Board Switchover Interval Type 0~11 0~11 None None None BSC6900None Read & Write Y BSC6900 Less than 5 minutes None
PN Port No. BSC6900 SET E1T1(Optional) E1/T1 port number None None Interval Type 0~335 0~31(AEUa/PEUa/EIUa), 0~62(E1 of OIUa), 0~83(T1 of OIUa), 0~125(E1 of AOUa/POUa), 0~167(T1 of AOUa/POUa), 0~251(E1 of AOUc/POUc), 0~335(T1 of AOUc/POUc) None None None E1/T1 port None Read & Write N (No impact on the UE in idle mode) Not involved Not involved If certain link is occupied, conversion from E1 to T1 or from T1 to E1 cannot be performed.
PN Port No. BSC6900 SET OPT(Optional) Port number None None Interval Type 0~7 0(OIUa), 0~1(AOUa/POUa), 0~3(UOIa/AOUc/POUc), 0~7(UOIc) None None None Board None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
PN Port No. BSC6900 SET COPTLNK(Optional) Port number None None Interval Type 0~7 0~7 None None None Channelized optical port None Read & Write N (No impact on the UE in idle mode) Not involved Not involved 1. This command is applicable to the boards AOUa and POUa.2. It is used for interworking with products of other manufacturers.
PN Port No. BSC6900 SET ETHPORT(Optional)ADD ETHREDPORT(Mandatory)ADD ETHIP(Mandatory)ADD ETHMEP(Mandatory) Ethernet port None None Interval Type 0~11 0~7(FG2a), 0~1(GOUa), 0~11(FG2c), 0~3(GOUc) None None None Ethernet port If port 0 or port 4 of the FG2a board is set to the GE port, the port number can only be 0 or 4. Otherwise, the port number ranges from 0 to 7. If only port 0 is set to the GE port, ports 1-3 are unavailable. If port 4 is set to the GE port, ports 5-7 are unavailable. Read & Write Not involved Not involved Not involved The parameter cannot be modified.
PN Physics port No. BSC6900 ADD IPLOGICPORT(Optional) FE/GE port number None None Interval Type 0~11 0~11 None None None IP logical port None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
PN Port No. BSC6900 STR IPCHK(Optional)STR ETHOAMLOOPTST(Mandatory) Ethernet port GBFD-118609IP Fault Detection Based on BFD Interval Type 0~11 0~7(FG2a), 0~1(GOUa), 0~11(FG2c), 0~3(GOUc) None None None None None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
PN Port No. BSC6900 CHK E1T1CRS(Mandatory) E1/T1 port number None None Interval Type 0~31 0~31 None None None E1/T1 port None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
PN Port No. BSC6900 STR FRPORTLOOP(Optional)ADD BC(Mandatory) Port number. GBFD-510002Gb Over FR Interval Type 0~335 0~335 None None None E1/T1 port None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
PN Port No. BSC6900 ADD PBSL(Mandatory) Port No. of Pb signaling link. GBFD-111203O&M of BSC Interval Type 0~335 0~335 None None None PBSL None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PN Port No. BSC6900 ADD BTSAUTOPLAN(Mandatory) Port No. of the BSC board connected with the BTS GBFD-111202O&M of BTS Interval Type 0~355 0~355 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PN Port No. BSC6900 SET BTSENVALMPORT(Mandatory)ADD BTSOBJALMSHLD(Mandatory) Alarm port number MRFD-210304Faulty Management Interval Type 0~255 0~255 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PN Port NO. BSC6900 SET BTSFORBIDTS(Mandatory)ADD BTSPPPLNK(Mandatory)ADD BTSMPLNK(Mandatory) Number of the port on the BTS side GBFD-111202O&M of BTS Interval Type 0~23 0~23 None None None PPP link None Read & Write Y BTS Less than 5 minutes None
PN Port NO. BSC6900 SET BTSOMLTS(Mandatory) Number of the port on the BTS side GBFD-111202O&M of BTS Interval Type 0~23 0~23 None None None BTS None Read & Write Y BTS Less than 5 minutes None
PN Port No. BSC6900 ADD BTSCONNECT(Mandatory) Number of the port through which the BTS is connected to the BSC GBFD-111202O&M of BTS Interval Type 0~335 0~335 None None None BTS None Read & Write Y BTS Less than 5 minutes This parameter can be modified only when the BTS is deactivated.
PN Port No. BSC6900 SET BTSETHPORT(Mandatory) Number of the FE or GE port GBFD-111202O&M of BTS Interval Type 0~1 0~1 None None None BTS None Read & Write Y BTS Less than 5 minutes None
PN Port No. BSC6900 ADD BTSETHLCMEP(Mandatory) Number of the Ethernet port. The number must be consistent with that of the port carrying the FE connection of the IP BTS. GBFD-111202O&M of BTS Interval Type 0~1 0~1 None None None BTS None Read & Write Y BTS Less than 5 minutes None
POCDELAY Transmission Delay of POC Service BSC6900 SET GCELLPSOTHERPARA(Optional) Maximum transmission delay of the POC service (push to talk over cellular). The transmission delay of the POC service must be relatively small. The network side must support the function of detecting the POC service type and reduce the delay through related processing to meet the POC service requirement. For the POC service received by the network side, Transfer Delay in the ABQP must be lower than the transmission threshold of the POC service. GBFD-119905PoC QoS Interval Type 250~650 250~650 None None 650 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
POCGBRMAX Max. GBR for POC Service BSC6900 SET GCELLPSOTHERPARA(Optional) Maximum bandwidth of the POC service (push to talk over cellular). The transmission delay of the POC service must be relatively small. The network side must support the function of detecting the POC service type and reduce the delay through related processing to meet the POC service requirement. For the POC service received by the network side, GbrValue in the ABQP must be lower than the maximum bandwidth of the POC service. GBFD-119905PoC QoS Interval Type 6~120 6~120 None None 16 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
POCGBRMIN Min. GBR for POC Service BSC6900 SET GCELLPSOTHERPARA(Optional) Minimum bandwidth of the POC service (push to talk over cellular). The transmission delay of the POC service must be relatively small. The network side must support the function of detecting the POC service type and reduce the delay through related processing to meet the POC service requirement. For the POC service received by the network side, GbrValue in the ABQP must be larger than the minimum bandwidth of the POC service. GBFD-119905PoC QoS Interval Type 6~120 6~120 None None 6 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PocSup POC Support BSC6900 SET GCELLPSOTHERPARA(Optional) Whether to support the push to talk over cellular (POC) service. GBFD-119905PoC QoS Enumeration Type NotSupport(Not Support), Support(Support) NotSupport, Support None None Support Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PODECTHRES Power Output Reduction Threshold BSC6900 SET GCELLOTHEXT(Optional) This parameter specifies a condition for generating a BTS alarm. When the output power of a TRX of a transmitter is lower than a fixed level, an error is generated. This parameter and "Power output error threshold" indicate the two thresholds of the error. If this parameter is set to a great value, the error is small. The value range is 0 to 9, indicating -10 dB to -1 dB. GBFD-111202O&M of BTS Interval Type 0~9 0~9 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
POERRTHRES Power Output Error Threshold BSC6900 SET GCELLOTHEXT(Optional) This parameter specifies a condition for generating a BTS alarm. When the output power of a TRX of a transmitter is lower than a fixed level, an error is generated. This parameter and "Power output reduction threshold" indicate the two thresholds of the error. If this parameter is set to a great value, the error is small. The value range is 0 to 9, indicating -10 dB to -1 dB. GBFD-111202O&M of BTS Interval Type 0~9 0~9 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved If this parameter is set to a greater value, the error is small.
POINTDESINFO Rollback Point Description BSC6900 ADD ROLLBACKPOINT(Optional) description of the rollback point. MRFD-210301Configuration Management String Type None 0~250 characters None None None BSC6900None Read & Write Not involved Not involved Not involved None
POINTNAME Rollback Point Name BSC6900 BEG ROLLBACK(Mandatory)BEG FORWARD(Mandatory)ADD ROLLBACKPOINT(Mandatory) name of the rollback point. MRFD-210301Configuration Management String Type None 1~250 characters None None None BSC6900None Read & Write Not involved Not involved Not involved None
Port Destination Port BSC6900 ADD FTPSCLTDPORT(Mandatory) This port is provided by the FTP server to be visited by the FTP client. GBFD-111203O&M of BSC Interval Type 21~65535 21~65535 None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PORT Port BSC6900 SWP BTSRING(Optional) Number of the port where to set up the link after the BTS ring is swapped. If this parameter is set to 0, the BTS works on a forward ring. If this parameter is set to 1, the BTS works on a backward ring. GBFD-117801Ring Topology Interval Type 0~1 0~1 None None None BTS None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
PORT Port BSC6900 SWP BTSOMLLINK(Optional) Number of the port where to set up the link after the main and backup OMLs of the BTS are swapped GBFD-113728OML Backup Interval Type 0~1 0~1 None None None BTS None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
PORTNO DXX In Port No. BSC6900 ADD DXXCONNECT(Mandatory) Number of the port that is connected to the DXX GBFD-111203O&M of BSC Interval Type 0~15 0~15 None None None BTS None Read & Write Y BTS Less than 5 minutes None
PORTNUM DXX Port Number BSC6900 ADD DXX(Optional) Maximum number of ports on the DXX GBFD-111203O&M of BSC Interval Type 1~16 1~16 None 16 16 BTS None Read & Write Y BTS Less than 5 minutes None
PORTPROTYPE Port protocol type BSC6900 ADD PORTFLOWCTRLPARA(Mandatory) Port protocol type None None Enumeration Type IP, ATM, HDLC IP, ATM, HDLC None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter can be added and modified. It cannot be deleted.
PortSwitch Panel Port Switch BSC6900 SET XPUPORT(Mandatory) Whether to enable the panel port of the XPUa/XPUb/SPUa/SPUb board MRFD-210301Configuration Management Enumeration Type CLOSE(Close), OPEN(Open) CLOSE, OPEN None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PORTTYPE Port Type BSC6900 ADD ETHMEP(Mandatory) Indicates the type of the physical port used by the local maintenance point in the maintenance group. FE indicates the FE port and TRUNK indicates the aggregation group. GBFD-118630Ethernet OAM Enumeration Type ETHER, TRUNK ETHER, TRUNK None None None Ethernet port None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
PORTTYPE Port Type BSC6900 ADD BTSTOPCONFIG(Mandatory) Type of the port. If this parameter is set to "TOPEXTOUTPORT", the local E1/T1 ports are used to extend the transmission of other boards. That is, the timeslots on the source E1/T1 port are used by other boards through the extended E1/T1 port. If this parameter is set to "TOPEXTINPORT", the local E1/T1 ports are used to extend the transmission of local boards. That is, the local boards can obtain the timeslots from other boards through the extended E1/T1 port. MRFD-211501IP-Based 2G/3G Co-Transmission on Base Station Side Enumeration Type TOPEXTOUTPORT(TOP Extended Out Port), TOPEXTINPORT(TOP Extended In Port) TOPEXTOUTPORT, TOPEXTINPORT None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
POT Patch Operation Type BSC6900 LOD BTSPATCH(Mandatory)CON BTSPATCH(Mandatory) Type of the patch operation GBFD-111202O&M of BTS Enumeration Type BYBTSTYPE(By BTS Type), BYBTS(By BTS) BYBTSTYPE, BYBTSNone None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
POWER Rated Power BSC6900 SET BTSAPMUBP(Optional) Rated maximum output power of the diesel engine. Refer to the rated output power described on the diesel engine label. GBFD-111202O&M of BTS Interval Type 1~1000 0.1~100 kVA None 125 BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
POWER_RELAY1 Switch for Relay 1 BSC6900 ADD EMU(Optional) Relay switch 1MRFD-210301Configuration Management Enumeration Type CLOSE(Close), OPEN(Open) CLOSE, OPEN None CLOSE None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
POWER_RELAY2 Switch for Relay 2 BSC6900 ADD EMU(Optional) Relay switch 2MRFD-210301Configuration Management Enumeration Type CLOSE(Close), OPEN(Open) CLOSE, OPEN None CLOSE None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
POWER_RELAY3 Switch for Relay 3 BSC6900 ADD EMU(Optional) Relay switch 3MRFD-210301Configuration Management Enumeration Type CLOSE(Close), OPEN(Open) CLOSE, OPEN None CLOSE None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
POWER_RELAY4 Switch for Relay 4 BSC6900 ADD EMU(Optional) Relay switch 4MRFD-210301Configuration Management Enumeration Type CLOSE(Close), OPEN(Open) CLOSE, OPEN None CLOSE None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
POWER_RELAY5 Switch for Relay 5 BSC6900 ADD EMU(Optional) Relay switch 5MRFD-210301Configuration Management Enumeration Type CLOSE(Close), OPEN(Open) CLOSE, OPEN None CLOSE None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
POWER_RELAY6 Switch for Relay 6 BSC6900 ADD EMU(Optional) Relay switch 6MRFD-210301Configuration Management Enumeration Type CLOSE(Close), OPEN(Open) CLOSE, OPEN None CLOSE None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
POWERCURRENTDIV Battery Shunt Coefficient BSC6900 SET BTSPMUBP(Optional) Battery current shunt coefficient GBFD-111202O&M of BTS Interval Type 0~1000 0~1000 None 100 None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
POWERREDUCE16QAM 16QAM Transmitter Power Reduce Level BSC6900 SET GCELLBASICPARA(Optional) 16QAM transmitter power reduce level of TS 7 of the BCCH. When the EDGE transmitter sends signals in 16QAM modulation mode, the EDGE transmitter adopts the power that is lower than the mean power of the GMSK modulation mode. Therefore, this parameter is required. GBFD-510804Downlink EGPRS2-A Interval Type 0~50 0~10, step: 0.2 dB None 0 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
POWERREDUCE32QAM 32QAM Transmitter Power Reduce Level BSC6900 SET GCELLBASICPARA(Optional) 32QAM transmitter power reduce level of TS 7 of the BCCH. When the EDGE transmitter sends signals in 32QAM modulation mode, the EDGE transmitter adopts the power that is lower than the mean power of the GMSK modulation mode. Therefore, this parameter is required. GBFD-510804Downlink EGPRS2-A Interval Type 0~50 0~10, step: 0.2 dB None 0 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
POWERTYPE Power Type BSC6900 SET BTSPMUBP(Optional) Power type managed by the PMU GBFD-111202O&M of BTS Enumeration Type POWER_48_24(48/24 Power Module), POWER_240_24(240/24 Power Module) POWER_48_24, POWER_240_24 None POWER_48_24None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
POWERTYPE Cabinet Power System Type BSC6900 SET BTSPOWERTYPE(Optional) Type of the power supply system of the cabinet GBFD-111202O&M of BTS Enumeration Type 220VAC(220V AC), N48VDC(-48V DC), P24VDC(+24V DC) 220VAC, N48VDC, P24VDC None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
POWL Power Level BSC6900 SET GTRXDEV(Optional) Transmit power level of the TRX. If this parameter is greater, the transmit power of the TRX is lower.If this parameter is set to 0, the TRX transmits at the highest power. At each level, the power is decreased by 2 dB. MRFD-210301Configuration Management Interval Type 0~13 0~13 None None None TRX None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
POWT Power Type BSC6900 SET GTRXDEV(Optional) Maximum power supported by the TRX. The macro BTSs and BTS3002C mini BTS support different power types. If this parameter is not set, the actual power type of the TRX board is used. MRFD-210301Configuration Management Enumeration Type 80W(80W), 63W(63W), 60W(60W), 55W(55W), 50W(50W), 45W(45W), 40W(40W), 31W(31W), 30W(30W), 27W(27W), 26W(26W), 25W(25W), 24W(24W), 21W(21W), 20W(20W), 19W(19W), 18W(18W), 17W(17W), 16W(16W), 15W(15W), 14W(14W), 13_3W(13.3W), 13W(13W), 12_5W(12.5W), 12W(12W), 11_5W(11.5W), 11W(11W), 10W(10W), 9_5W(9.5W), 9W(9W), 8_5W(8.5W), 8W(8W), 7_5W(7.5W), 7W(7W), 6_5W(6.5W), 6W(6W), 5_5W(5.5W), 5W(5W), 4_5W(4.5W), 4W(4W), 3_7W(3.7W), 3_1W(3.1W), 3W(3W), 2_5W(2.5W), 2W(2W), 200mW(200mW), DEFAULT(Default) 80W, 63W, 60W, 55W, 50W, 45W, 40W, 31W, 30W, 27W, 26W, 25W, 24W, 21W, 20W, 19W, 18W, 17W, 16W, 15W, 14W, 13_3W, 13W, 12_5W, 12W, 11_5W, 11W, 10W, 9_5W, 9W, 8_5W, 8W, 7_5W, 7W, 6_5W, 6W, 5_5W, 5W, 4_5W, 4W, 3_7W, 3_1W, 3W, 2_5W, 2W, 200mW, DEFAULT None None None TRX None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PPPLNKN PPP link No. BSC6900 ADD PPPLNK(Optional) PPP link number GBFD-118611GBFD-118622 Abis IP over E1/T1A IP over E1/T1 Interval Type 0~499 0~499 None None None PPP link None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
PPPLNKN PPP sub-link No. BSC6900 ADD MPLNK(Optional) PPP link number GBFD-118611GBFD-118622 Abis IP over E1/T1A IP over E1/T1 Interval Type 0~499 0~499 None None None MP link None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PPPLNKN PPP link No. BSC6900 ADD IPLOGICPORT(Optional) PPP link number None None Interval Type 0~499 0~499 None None None IP logical port None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PPPLNKN PPP link No. BSC6900 ADD BTSPPPLNK(Mandatory)ADD BTSMPLNK(Mandatory) Number of the PPP link GBFD-118611Abis IP over E1/T1 Interval Type 0~15 0~15 None None None PPP link None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
PPPMUX PPP mux BSC6900 ADD PPPLNK(Optional) If this parameter is to ENABLE, the multiplexing frame function of the PPP link is enabled. If this parameter is to DISABLE, the multiplexing frame function of the PPP link is disabled. GBFD-118611GBFD-118622 Abis IP over E1/T1A IP over E1/T1 Enumeration Type Disable(Disable), Enable(Enable) Disable, Enable None Enable Enable PPP link None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
PPPMUX PPP mux BSC6900 ADD MPGRP(Optional) If this parameter is to ENABLE, the multiplexing frame function of the PPP link is enabled. If this parameter is to DISABLE, the multiplexing frame function of the PPP link is disabled. GBFD-118611GBFD-118622 Abis IP over E1/T1A IP over E1/T1 Enumeration Type Disable(Disable), Enable(Enable) Disable, Enable None Disable Disable MP groupNone Read & Write N (No impact on the UE in idle mode) Not involved Not involved ENABLE: the multiplexing frame function of the PPP link is enabled. DISABLE: the multiplexing frame function of the PPP link is disabled.
PQNUM Priority queue number BSC6900 ADD PORTFLOWCTRLPARA(Optional) This parameter is valid only when the port flow control type is IP. The "PQNUM" of an ATM queue is "2" by default. You cannot change the default value. None None Interval Type 0~5 0~5 None 2 2 BSC6900When the value of "PORTPROTYPE" in "ADD PORTFLOWCTRLPARA" is set to IP, this parameter should be set. Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter can be added or modified but cannot be removed.
PREEMPTIONPERMIT Emergency Call Preemption Permitted BSC6900 SET GCELLCCAD(Optional) If this parameter is set to ON, the BSC initiates a TCHF preemption when receiving a link establishment indication from an MS in an emergency call. GBFD-110202Emergency Call Service (TS12) Enumeration Type OFF(Off), ON(On) OFF, ON None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PREMRSAMPLE Preprocess MR Sample Ratio BSC6900 SET GMRCTRL(Optional) Sampling rate of pre-processed measurement reports. GBFD-110802Pre-processing of Measurement Report Interval Type 1~255 1~255 None None 1 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved When the sampling rate of pre-processed measurement reports is set to 1, the frequency of submitting pre-processed measurement reports should be set to one report per two seconds or one report per four seconds.
PRI Route PRI BSC6900 ADD BTSIPRT(Optional) A smaller value indicates a higher priority. The BTS preferentially selects the route with a high priority to transfer information. GBFD-118601Abis over IP Interval Type 0~255 0~255 None 60 60 BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PRIACCTHR Packet Access Priority BSC6900 SET GCELLPSBASE(Optional) Access priority of the MS that is allowed to access the cell. The MS sends the packet channel request containing the 2-bit radio priority message. The priority of the 2-bit radio priority message ranges from 1 to 4 in descending order. During the MS access, the BSC compares the radio priority in the channel request with the parameter setting of the cell. If the radio priority equals to the parameter setting of the cell, the BSC sets up the TBF for the channel request. GBFD-114101GPRS Enumeration Type 0(No packet access), 3(Packet access of level 1), 4(Packet access of levels 1-2), 5(Packet access of levels 1-3), 6(Packet access of level 1-4) 0, 3, 4, 5, 6 None None 6 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PRIFCEN Support Priority Based Flow Control BSC6900 SET BSCFCPARA(Optional) This parameter specifies whether to support flow control based on priority. When this parameter is set to on, the system preferentially admits the calls initiated by VIP users. GBFD-111705GSM Flow Control Enumeration Type NO(No), YES(Yes)NO, YES None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PRIMMESPPT Transfer Original MR BSC6900 SET GCELLHOCTRL(Optional) Whether the BTSs send the original measurement reports to the BSC after pre-processing them. When this parameter is set to YES, the BTSs sends the original and pre-processed measurement reports to the BSC. GBFD-110802Pre-processing of Measurement Report Enumeration Type NO(No), YES(Yes)NO, YES None None NO Cell This parameter must be set when "BTSMESRPTPREPROC" is set to BTS_Preprocessing. This parameter must be set to NO when "MPMODE" of the BTS that serving this cell is set to MODE4_1 and there are more than two SDCCHs. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PRINTCTHD Print control threshold BSC6900 SET FCCPUTHD(Optional) Printing control threshold. If the CPU usage of sliding windows reaches or exceeds the threshold, printing flow control is triggered on the serial port. WRFD-040100Flow Control Interval Type 30~100 30~100 per cent None 60 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PRINTCTHD Print control threshold BSC6900 SET FCMSGQTHD(Optional) Printing control threshold. When the packet queue usage of sliding windows reaches or exceeds the threshold, printing flow control is triggered on the serial port. WRFD-040100Flow Control Interval Type 30~100 30~100 per cent None 72 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PRINTRTHD Print restore threshold BSC6900 SET FCCPUTHD(Optional) Printing control threshold. If the CPU usage of sliding windows is lower than the threshold, printing flow control on the serial port is stopped. WRFD-040100Flow Control Interval Type 30~100 30~100 per cent None 50 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PRINTRTHD Print restore threshold BSC6900 SET FCMSGQTHD(Optional) Printing control threshold. When the packet queue usage of sliding windows is lower than the threshold, printing flow control on the serial port is stopped. WRFD-040100Flow Control Interval Type 30~100 30~100 per cent None 65 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PRINTSW Print Flow control switch BSC6900 SET FCSW(Optional) Whether to control the printing flow on the serial port WRFD-040100Flow Control Enumeration Type ON, OFF ON, OFF None None ON Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PRIOR Cell Priority BSC6900 SET GCELLBASICPARA(Optional) This parameter controls handover between cells at the same layer. Generally, the cells at the same layer have the same priority. If the cells at the same layer have different priorities, the cell with a smaller value has a higher priority. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Enumeration Type PRIOR-1(Priority-1), PRIOR-2(Priority-2), PRIOR-3(Priority-3), PRIOR-4(Priority-4), PRIOR-5(Priority-5), PRIOR-6(Priority-6), PRIOR-7(Priority-7), PRIOR-8(Priority-8), PRIOR-9(Priority-9), PRIOR-10(Priority-10), PRIOR-11(Priority-11), PRIOR-12(Priority-12), PRIOR-13(Priority-13), PRIOR-14(Priority-14), PRIOR-15(Priority-15), PRIOR-16(Priority-16) PRIOR-1, PRIOR-2, PRIOR-3, PRIOR-4, PRIOR-5, PRIOR-6, PRIOR-7, PRIOR-8, PRIOR-9, PRIOR-10, PRIOR-11, PRIOR-12, PRIOR-13, PRIOR-14, PRIOR-15, PRIOR-16 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved Each layer has 16 priorities, numbered 1-16 respectively. If the number of the priority is small, the priority is high. This parameter along with Layer of the Cell determines the priority of a cell. The priority affects the sequence of neighboring cells for handover. It also affects handover algorithms, such as PBGT handover algorithm and inter-layer handover algorithm. For example, PBGT handovers can be performed only between the cells at the same layer and hierarchy. If a 1800 MHz cell and a 900 MHz cell are at different layers, a PBGT handover cannot be performed from the 1800 MHz cell to the 900 MHz cell. Consequently, handovers are performed slowly even if the speech quality is good.
PRIOR Cell priority BSC6900 ADD GEXT2GCELL(Optional) This parameter controls the handovers among cells on a same layer. A smaller priority value indicates a higher priority. Cells with higher priorities are preferentially selected as the handover target cells. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Enumeration Type Prior-1, Prior-2, Prior-3, Prior-4, Prior-5, Prior-6, Prior-7, Prior-8, Prior-9, Prior-10, Prior-11, Prior-12, Prior-13, Prior-14, Prior-15, Prior-16 Prior-1, Prior-2, Prior-3, Prior-4, Prior-5, Prior-6, Prior-7, Prior-8, Prior-9, Prior-10, Prior-11, Prior-12, Prior-13, Prior-14, Prior-15, Prior-16 None None Prior-1 Cell This parameter, together with "LAYER", determines the priority of the cell. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PRIORABISLOADTHRED Flex Abis Prior Choose Load Thred BSC6900 SET BTSFLEXABISPARA(Optional) If the static Abis resource load is greater than the value of "Fix Abis Prior Choose Abis Load Thred" and the dynamic Abis resource load is greater than the value of this parameter, the half-rate channel is preferred. Otherwise, the full-rate channel is preferred. GBFD-117301Flex Abis Interval Type 0~100 0~100 per cent None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PRIORCLASS Cell HCS Prior Class BSC6900 SET GCELLSERVPARA(Optional) Priority of the hierarchical cell structure (HCS). 0: indicates the lowest priority; 7: indicates the highest priority. GBFD-114101GPRS Enumeration Type 0(0), 1(1), 2(2), 3(3), 4(4), 5(5), 6(6), 7(7), nouse(no use) 0, 1, 2, 3, 4, 5, 6, 7, no use None None 2 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
5/5/2014
Confidential Information of Huawei.
No Spreading without Permission
Page15of42
226347869.xls.ms_office Security Level:
PRIORITY Route priority BSC6900 ADD MTP3RT(Optional)ADD M3RT(Optional) Route priority. The highest priority is represented by 0. None None Interval Type 0~99 0~99 None 0 0 MTP3 linkNone Read & Write N (No impact on the UE in idle mode) Not involved Not involved The routing priority is modified. In the case of multiple routes to the same signaling point, the route priority is affected.
PRIORITY Signalling link priority BSC6900 ADD MTP3LNK(Optional)ADD M3LNK(Optional) Priority of the signaling link. 0 indicates the highest priority. None None Interval Type 0~99 0~99 None 0 0 None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PRIORITY Priority BSC6900 ADD IPRT(Mandatory) Route priority. The boards FG2a, GOUa, UOIa(IP), FG2c, and GOUc support the configuration of routes with different priorities. Suppose two or more routes are configured and their addresses and masks are the same, and the addresses of the next hops and priorities. These routes can be configured in the active and standby mode. When the route with higher priority is available and only this route is valid, the system switches to the route with lower priority once the route with higher priority fails. None None Enumeration Type HIGH, LOW HIGH, LOW None None None IP route None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
PrivKey Private Key File Name BSC6900 SET CERTFILE(Optional) Name of the private key file MRFD-210305Security Management String Type None 0~200 characters None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PROT SS7 protocol type BSC6900 ADD N7DPC(Optional) To identify the DSP protocol type,including ITUT(International Telecommunication Union - Telecommunication Standardization Sector),ANSI(American National Standards Institute) and TTC(Telecommunication Technology Committee (Japan)). None None Enumeration Type ITUT(ITUT), ANSI(ANSI), TTC(TTC) ITUT, ANSI, TTC None ITUT ITUT SCCP None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
PROT Frame Relay Protocol Type BSC6900 ADD BC(Optional) Protocol type of the trunk frame. GBFD-510002Gb Over FR Enumeration Type Q933(Q933), ANSI(Ansi) Q933, ANSI None Q933 Q933 BC None Read & Write Y BC Services are interrupted until the parameter is consistent with the SGSN at the peer end. None
PROTECTDELAYTIME Protection Delay for Detection BSC6900 SET BTSABISTROP(Optional) The transmission resource in the Abis timeslot is considered as faulty only when the BTS detects that the Abis timeslot is faulty in the delay. The transmission resource in the Abis timeslot is considered as normal when the BTS detects the Abis timeslot is normal. None None Interval Type 5~300 5~300 s None 15 BSC6900None Read & Write Not involved Not involved Not involved None
PROTECTTIME Dyn. Turning Off Cell Protection Time BSC6900 SET GCELLDYNTURNOFF(Optional) After a cell is turned on, it cannot be turned off in "Dyn. Turning Off Cell Protection Time"; after a cell is turned off, it cannot be turned on in "Dyn. Turning Off Cell Protection Time". GBFD-111610Dynamic Cell Power Off Interval Type 0~255 0~255 min None 5 Cell This parameter is valid only when "TURNOFFENABLE" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ProtectTimeTrxPowerOn TRX Power-on Protection Time BSC6900 SET BSCDSTPA(Optional) To prevent the BSC from frequently disabling or enabling the power amplifier of a carrier, the system disallows the BSC from disabling the power amplifier of the carrier within the time specified by this parameter after the carrier is powered on. GBFD-111602TRX Power Amplifier Intelligent Shutdown Interval Type 60~3600 60~3600 s None 300 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PS Port select BSC6900 SET E1T1(Optional)CHK E1T1CRS(Mandatory) Port selection None None Enumeration Type ALL(Select all ports), SINGLE(Select one port) ALL, SINGLE None None ALL E1/T1 port None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
PS Port select BSC6900 SET OPT(Optional) Port selection None None Enumeration Type ALL(Select all ports), SINGLE(Select one port) ALL, SINGLE None None None Board None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
PS Port select BSC6900 SET COPTLNK(Mandatory) Port selection None None Enumeration Type ALL(Select all E1/T1 ports), PORT(Select all E1/T1 ports of one channelized optical port), SINGLE(Select one E1/T1 port) ALL, PORT, SINGLE None None ALL Channelized optical port None Read & Write N (No impact on the UE in idle mode) Not involved Not involved 1. This command is applicable to the boards AOUa and POUa.2. It is used for interworking with products of other manufacturers.
PSBKGDL UMTS R99 PS background service downlink factor BSC6900 ADD TRMFACTOR(Optional) WCDMA R99 PS background service downlink factor None None Interval Type 0~100 0~100 per cent 100 100 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node that is configured with the factor table. After the successful modification, the parameter takes effect in the following two cases:1. New access subscriber. 2. Bandwidth modification of the existing subscriber
PSBKGPRIPATH R99 PS background primary path BSC6900 ADD TRMMAP(Optional) R99 PS background service bearer primary path None None Enumeration Type CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF None None When the interface type is Iub, transmission type is ATM or dual stack, the parameter is RT_VBR; transimssion type is IP or Hybird IP, the parameter is AF13.When the interface type is Iur, transmission type is ATM, the parameter is RT_VBR; transimssion type is IP, the parameter is AF13.When the interface type is Iu-PS, the parameter is AF13. BSC6900When the value of "ITFT" in "ADD TRMMAP" is set to IUB or IUR or IUPS, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node configured with the TRMMAP. After the successful modification, it is valid in the case of the new access of a subscriber and the bandwidth modification of an existing subscriber.
PSBKGSECPATH R99 PS background secondary path BSC6900 ADD TRMMAP(Optional) R99 PS background service bearer secondary path None None Enumeration Type CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF, NULL CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF, NULL None None When the interface type is Iub, transmission type is ATM or IP, the parameter is NULL; transimssion type is dual stack, the parameter is AF13; transimssion type is Hybird IP, the parameter is LQAF13.When the interface type is Iur, transmission type is ATM or IP, the parameter is NULL.When the interface type is Iu-PS, the parameter is NULL. BSC6900When the value of "ITFT" in "ADD TRMMAP" is set to IUB or IUR, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node configured with the TRMMAP. After the successful modification, it is valid in the case of the new access of a subscriber and the bandwidth modification of an existing subscriber.
PSBKGUL UMTS R99 PS background service uplink factor BSC6900 ADD TRMFACTOR(Optional) WCDMA R99 PS background service uplink factor None None Interval Type 0~100 0~100 per cent 100 100 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node that is configured with the factor table. After the successful modification, the parameter takes effect in the following two cases:1. New access subscriber. 2. Bandwidth modification of the existing subscriber
PSCONVDL UMTS R99 PS conversational service downlink factor BSC6900 ADD TRMFACTOR(Optional) WCDMA R99 PS conversational service downlink factor None None Interval Type 0~100 0~100 per cent 70 70 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node that is configured with the factor table. After the successful modification, the parameter takes effect in the following two cases:1. New access subscriber. 2. Bandwidth modification of the existing subscriber
PSCONVPRIPATH R99 PS conversational primary path BSC6900 ADD TRMMAP(Optional) R99 PS conversational service primary path None None Enumeration Type CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF None None When the interface type is Iub, transmission type is ATM or dual stack, the parameter is RT_VBR; transimssion type is IP or Hybird IP, the parameter is AF43.When the interface type is Iur, transmission type is ATM, the parameter is RT_VBR; transimssion type is IP, the parameter is AF43.When the interface type is Iu-PS, the parameter is AF43. BSC6900When the value of "ITFT" in "ADD TRMMAP" is set to IUB or IUR or IUPS, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node configured with the TRMMAP. After the successful modification, it is valid in the case of the new access of a subscriber and the bandwidth modification of an existing subscriber.
PSCONVSECPATH R99 PS conversational secondary path BSC6900 ADD TRMMAP(Optional) R99 PS conversational service secondary path None None Enumeration Type CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF, NULL CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF, NULL None None When the interface type is Iub, transmission type is ATM or IP, the parameter is NULL; transimssion type is dual stack, the parameter is AF43; transimssion type is Hybird IP, the parameter is LQAF43.When the interface type is Iur, transmission type is ATM or IP, the parameter is NULL.When the interface type is Iu-PS, the parameter is NULL. BSC6900When the value of "ITFT" in "ADD TRMMAP" is set to IUB or IUR, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node configured with the TRMMAP. After the successful modification, it is valid in the case of the new access of a subscriber and the bandwidth modification of an existing subscriber.
PSCONVUL UMTS R99 PS conversational service uplink factor BSC6900 ADD TRMFACTOR(Optional) WCDMA R99 PS conversational service uplink factor None None Interval Type 0~100 0~100 per cent 70 70 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node that is configured with the factor table. After the successful modification, the parameter takes effect in the following two cases:1. New access subscriber. 2. Bandwidth modification of the existing subscriber
PSDATADL GSM PS data service downlink factor BSC6900 ADD TRMFACTOR(Optional) GSM PS data service downlink factor None None Interval Type 0~100 0~100 per cent 100 100 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node that is configured with the factor table. After the successful modification, the parameter takes effect in the following two cases:1. New access subscriber. 2. Bandwidth modification of the existing subscriber
PSDATAUL GSM PS data service uplink factor BSC6900 ADD TRMFACTOR(Optional) GSM PS data service uplink factor None None Interval Type 0~100 0~100 per cent 100 100 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node that is configured with the factor table. After the successful modification, the parameter takes effect in the following two cases:1. New access subscriber. 2. Bandwidth modification of the existing subscriber
PSHOSUP PS Handover Support BSC6900 ADD NSE(Optional) Whether to support PS Handover(PS HO). The PS HO is used to reduce the interval of the cell reselection of the MS. GBFD-119502PS Handover Enumeration Type NO(No Support), YES(Support) NO, YES None NO NO NSE None Read & Write Y NSE Less than 5 minutes The SIGBVC must be reset after this switch is turned on. The BSC supports the PS HO when the SGSN supports the PS HO.
PSHPRIDATAPATH PS high PRI data path BSC6900 ADD TRMMAP(Optional) PS high PRI data path None None Enumeration Type BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF None None When the interface type is Abis, the parameter is AF43. BSC6900When the value of "ITFT" in "ADD TRMMAP" is set to ABIS, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node configured with the TRMMAP. After the successful modification, it is valid in the case of the new access of a subscriber and the bandwidth modification of an existing subscriber.
PSHPRIDATAPRI PS high PRI data priority BSC6900 ADD TRMMAP(Optional) PS high PRI data priority None None Interval Type 0~7 0~7 None None When the interface type is Abis and transmission type is HDLC, the parameter is 0. BSC6900When the value of "ITFT" in "ADD TRMMAP" is set to ABIS, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node configured with the TRMMAP. After the successful modification, it is valid in the case of the new access of a subscriber and the bandwidth modification of an existing subscriber.
PSHPSP PS High PRI Service PRI BSC6900 ADD GCELL(Optional) Priority of the PS high priority service GBFD-111705GSM Flow Control Interval Type 0~7 0~7 None 4 4 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved If this parameter is set to a larger value, more packets are discarded when the congestion occurs. Thus, the priority value of the major service should be smaller than that of the minor service.
PSI1RPT PSI1 Repetition Period BSC6900 SET GCELLPSI1(Optional) Period for sending the packet message PSI. If the period is too long, the message PSI cannot be obtained in realtime. If the period is too short, the message PSI is broadcast frequently, which occupies too much system resources. GBFD-119102Packet System Information Interval Type 1~16 1~16 None None 6 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PSINTERDL UMTS R99 PS interactive service downlink factor BSC6900 ADD TRMFACTOR(Optional) WCDMA R99 PS interactive service downlink factor None None Interval Type 0~100 0~100 per cent 100 100 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node that is configured with the factor table. After the successful modification, the parameter takes effect in the following two cases:1. New access subscriber. 2. Bandwidth modification of the existing subscriber
PSINTERUL UMTS R99 PS interactive service uplink factor BSC6900 ADD TRMFACTOR(Optional) WCDMA R99 PS interactive service uplink factor None None Interval Type 0~100 0~100 per cent 100 100 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node that is configured with the factor table. After the successful modification, the parameter takes effect in the following two cases:1. New access subscriber. 2. Bandwidth modification of the existing subscriber
PSINTHGHPRIPATH R99 PS high PRI interactive primary path BSC6900 ADD TRMMAP(Optional) R99 PS high PRI interactive primary path None None Enumeration Type CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF None None When the interface type is Iub, transmission type is ATM or dual stack, the parameter is RT_VBR; transimssion type is IP or Hybird IP, the parameter is AF33.When the interface type is Iur, transmission type is ATM, the parameter is RT_VBR; transimssion type is IP, the parameter is AF33.When the interface type is Iu-PS, the parameter is AF33. BSC6900When the value of "ITFT" in "ADD TRMMAP" is set to IUB or IUR or IUPS, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node configured with the TRMMAP. After the successful modification, it is valid in the case of the new access of a subscriber and the bandwidth modification of an existing subscriber.
PSINTHGHSECPATH R99 PS high PRI interactive secondary path BSC6900 ADD TRMMAP(Optional) R99 PS high PRI interactive secondary path None None Enumeration Type CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF, NULL CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF, NULL None None When the interface type is Iub, transmission type is ATM or IP, the parameter is NULL; transimssion type is dual stack, the parameter is AF33; transimssion type is Hybird IP, the parameter is LQAF33.When the interface type is Iur, transmission type is ATM or IP, the parameter is NULL.When the interface type is Iu-PS, the parameter is NULL. BSC6900When the value of "ITFT" in "ADD TRMMAP" is set to IUB or IUR, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node configured with the TRMMAP. After the successful modification, it is valid in the case of the new access of a subscriber and the bandwidth modification of an existing subscriber.
PSINTLOWPRIPATH R99 PS low PRI interactive primary path BSC6900 ADD TRMMAP(Optional) R99 PS low PRI interactive primary path None None Enumeration Type CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF None None When the interface type is Iub, transmission type is ATM or dual stack, the parameter is RT_VBR; transimssion type is IP or Hybird IP, the parameter is AF33.When the interface type is Iur, transmission type is ATM, the parameter is RT_VBR; transimssion type is IP, the parameter is AF33.When the interface type is Iu-PS, the parameter is AF33. BSC6900When the value of "ITFT" in "ADD TRMMAP" is set to IUB or IUR or IUPS, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node configured with the TRMMAP. After the successful modification, it is valid in the case of the new access of a subscriber and the bandwidth modification of an existing subscriber.
PSINTLOWSECPATH R99 PS low PRI interactive secondary path BSC6900 ADD TRMMAP(Optional) R99 PS low PRI interactive secondary path None None Enumeration Type CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF, NULL CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF, NULL None None When the interface type is Iub, transmission type is ATM or IP, the parameter is NULL; transimssion type is dual stack, the parameter is AF33; transimssion type is Hybird IP, the parameter is LQAF33.When the interface type is Iur, transmission type is ATM or IP, the parameter is NULL.When the interface type is Iu-PS, the parameter is NULL. BSC6900When the value of "ITFT" in "ADD TRMMAP" is set to IUB or IUR, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node configured with the TRMMAP. After the successful modification, it is valid in the case of the new access of a subscriber and the bandwidth modification of an existing subscriber.
PSINTMIDPRIPATH R99 PS middle PRI interactive primary path BSC6900 ADD TRMMAP(Optional) R99 PS middle PRI interactive primary path None None Enumeration Type CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF None None When the interface type is Iub, transmission type is ATM or dual stack, the parameter is RT_VBR; transimssion type is IP or Hybird IP, the parameter is AF33.When the interface type is Iur, transmission type is ATM, the parameter is RT_VBR; transimssion type is IP, the parameter is AF33.When the interface type is Iu-PS, the parameter is AF33. BSC6900When the value of "ITFT" in "ADD TRMMAP" is set to IUB or IUR or IUPS, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node configured with the TRMMAP. After the successful modification, it is valid in the case of the new access of a subscriber and the bandwidth modification of an existing subscriber.
PSINTMIDSECPATH R99 PS middle PRI interactive secondary path BSC6900 ADD TRMMAP(Optional) R99 PS middle PRI interactive secondary path None None Enumeration Type CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF, NULL CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF, NULL None None When the interface type is Iub, transmission type is ATM or IP, the parameter is NULL; transimssion type is dual stack, the parameter is AF33; transimssion type is Hybird IP, the parameter is LQAF33.When the interface type is Iur, transmission type is ATM or IP, the parameter is NULL.When the interface type is Iu-PS, the parameter is NULL. BSC6900When the value of "ITFT" in "ADD TRMMAP" is set to IUB or IUR, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node configured with the TRMMAP. After the successful modification, it is valid in the case of the new access of a subscriber and the bandwidth modification of an existing subscriber.
PSISTATUSIND Support PSI Status Message BSC6900 SET GCELLPSI1(Optional) Whether the BSC supports the state message PSI. The state message PSI refers to PSI STATUS. GBFD-119102Packet System Information Enumeration Type NO(No), YES(Yes)NO, YES None None NO Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PSLPRIDATAPATH PS low PRI data path BSC6900 ADD TRMMAP(Optional) PS low PRI data path None None Enumeration Type BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF None None When the interface type is Abis, the parameter is AF43. BSC6900When the value of "ITFT" in "ADD TRMMAP" is set to ABIS, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node configured with the TRMMAP. After the successful modification, it is valid in the case of the new access of a subscriber and the bandwidth modification of an existing subscriber.
PSLPRIDATAPRI PS low PRI data priority BSC6900 ADD TRMMAP(Optional) PS low PRI data priority None None Interval Type 0~7 0~7 None None When the interface type is Abis and transmission type is HDLC, the parameter is 0. BSC6900When the value of "ITFT" in "ADD TRMMAP" is set to ABIS, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node configured with the TRMMAP. After the successful modification, it is valid in the case of the new access of a subscriber and the bandwidth modification of an existing subscriber.
PSLPSVP PS Low PRI Service PRI BSC6900 ADD GCELL(Optional) Priority of the PS low priority service GBFD-111705GSM Flow Control Interval Type 0~7 0~7 None 6 6 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved If this parameter is set to a larger value, more packets are discarded when the congestion occurs. Thus, the priority value of the major service should be smaller than that of the minor service.
PSOTOURECEIVETHRSH PS OtoU HO Receive Level Threshold BSC6900 SET GCELLHOIUO(Optional) Threshold of the receive level for triggering the handover of the PS services from the overlaid subcell to the underlaid subcell. None None Interval Type 0~63 0~63 None None 25 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PSRACHACCLEV PS RACH Min. Access Level BSC6900 SET GCELLCCACCESS(Optional) Minimum access level of the random access channel (RACH) in the PS domain GBFD-119110Access Interval Type -121~-109 -121~-109 dBm None -115 Cell The value of this parameter must be smaller than "RACH Busy Threshold" in the "SET GCELLCCBASIC" command. Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter should be set on the basis of the actual receiver sensitivity of the BTS and the minimum access level of the MS to avoid the situation where a call cannot be made even though there are signals detected.
PSRACHACCLEV PS RACH Min. Access Level BSC6900 SET GCELLRACHCCLEV(Optional) Level threshold of the MS random access in the PS domain. For the BTS3X and the double-transceiver BTSs, this parameter settings affect the MS access. If the receive level of the RACH burst is lower than RACH Min.Access Level, the BTS regards this access as an invalid one and no decoding is performed. If the receive level of the RACH burst is higher than RACH Min. Access Level, the BTS considers that an access request exists on this timeslot, and determines together with the value of Random Access Error Threshold whether the RACH access is valid. GBFD-111003Radio Common Channel Management Interval Type -121~-47 -121~-47 dBm None -109 Cell The value of this parameter must be smaller than "RACH Busy Threshold" in the "SET GCELLCCBASIC" command. Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter should be set on the basis of the actual receiver sensitivity of the BTS and the minimum access level of the MS to avoid the situation where a call cannot be made even though there are signals detected.
PSRACJACCLEV PS Min.Access Level BSC6900 ADD BTSLOCGRP(Optional) Minimum voltage level for accessing PS services of the location group GBFD-510104Multi-site Cell Interval Type -121~-47 -121~-47 dBm None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PSRESREQMSGNUMINPERIOD Max PS Resource REQ Num in Period BSC6900 SET BSCFCPARA(Optional) Maximum number of messages in the statistical period for the arrival of PS resource requests GBFD-111705GSM Flow Control Interval Type 10~10000 10~10000 None None 500 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PSRESREQSTATPERIOD PS Resource REQ Statistical Period BSC6900 SET BSCFCPARA(Optional) Statistical period for the arrival of PS resource requests GBFD-111705GSM Flow Control Interval Type 100~600000 100~600000 ms None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PSSTRMDL UMTS R99 PS streaming service downlink factor BSC6900 ADD TRMFACTOR(Optional) WCDMA R99 PS streaming service downlink factor None None Interval Type 0~100 0~100 per cent 100 100 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node that is configured with the factor table. After the successful modification, the parameter takes effect in the following two cases:1. New access subscriber. 2. Bandwidth modification of the existing subscriber
PSSTRMPRIPATH R99 PS streaming primary path BSC6900 ADD TRMMAP(Optional) R99 PS streaming service bearer primary path None None Enumeration Type CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF None None When the interface type is Iub, transmission type is ATM or dual stack, the parameter is RT_VBR; transimssion type is IP or Hybird IP, the parameter is AF43.When the interface type is Iur, transmission type is ATM, the parameter is RT_VBR; transimssion type is IP, the parameter is AF43.When the interface type is Iu-PS, the parameter is AF43. BSC6900When the value of "ITFT" in "ADD TRMMAP" is set to IUB or IUR or IUPS, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node configured with the TRMMAP. After the successful modification, it is valid in the case of the new access of a subscriber and the bandwidth modification of an existing subscriber.
PSSTRMSECPATH R99 PS streaming secondary path BSC6900 ADD TRMMAP(Optional) R99 PS streaming service bearer secondary path None None Enumeration Type CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF, NULL CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF, NULL None None When the interface type is Iub, transmission type is ATM or IP, the parameter is NULL; transimssion type is dual stack, the parameter is AF43; transimssion type is Hybird IP, the parameter is LQAF43.When the interface type is Iur, transmission type is ATM or IP, the parameter is NULL.When the interface type is Iu-PS, the parameter is NULL. BSC6900When the value of "ITFT" in "ADD TRMMAP" is set to IUB or IUR, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node configured with the TRMMAP. After the successful modification, it is valid in the case of the new access of a subscriber and the bandwidth modification of an existing subscriber.
PSSTRMUL UMTS R99 PS streaming service uplink factor BSC6900 ADD TRMFACTOR(Optional) WCDMA R99 PS streaming service uplink factor None None Interval Type 0~100 0~100 per cent 100 100 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node that is configured with the factor table. After the successful modification, the parameter takes effect in the following two cases:1. New access subscriber. 2. Bandwidth modification of the existing subscriber
PSU0 DPSU 0 Configured BSC6900 SET BTSAPMUBP(Optional)SET BTSDPMUBP(Optional) Whether to enable the DPSU0 to supply power for the BTS.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. GBFD-111202O&M of BTS Enumeration Type NO(NO), YES(YES) NO, YES None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PSU1 DPSU 1 Configured BSC6900 SET BTSAPMUBP(Optional)SET BTSDPMUBP(Optional) Whether to enable the DPSU1 to supply power for the BTS.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. GBFD-111202O&M of BTS Enumeration Type NO(NO), YES(YES) NO, YES None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PSU2 DPSU 2 Configured BSC6900 SET BTSAPMUBP(Optional) Whether to enable the DPSU2 to supply power for the BTS.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. GBFD-111202O&M of BTS Enumeration Type NO(NO), YES(YES) NO, YES None None For "APMU Board Type" is "APM30" or "APM4815", the recommended value is "NO". For other types of APMU boards, the recommended value is "YES". BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PSU2 DPSU 2 Configured BSC6900 SET BTSDPMUBP(Optional) Whether to enable the DPSU2 to supply power for the BTS.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. GBFD-111202O&M of BTS Enumeration Type NO(NO), YES(YES) NO, YES None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PSU3 DPSU 3 Configured BSC6900 SET BTSDPMUBP(Optional) Whether to enable the DPSU3 to supply power for the BTS.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. GBFD-111202O&M of BTS Enumeration Type NO(NO), YES(YES) NO, YES None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PSU4 DPSU 4 Configured BSC6900 SET BTSDPMUBP(Optional) Whether to enable the DPSU4 to supply power for the BTS.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. GBFD-111202O&M of BTS Enumeration Type NO(NO), YES(YES) NO, YES None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PSU5 DPSU 5 Configured BSC6900 SET BTSDPMUBP(Optional) Whether to enable the DPSU5 to supply power for the BTS.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. GBFD-111202O&M of BTS Enumeration Type NO(NO), YES(YES) NO, YES None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PSU6 DPSU 6 Configured BSC6900 SET BTSDPMUBP(Optional) Whether to enable the DPSU6 to supply power for the BTS.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. GBFD-111202O&M of BTS Enumeration Type NO(NO), YES(YES) NO, YES None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PSU7 DPSU 7 Configured BSC6900 SET BTSDPMUBP(Optional) Whether to enable the DPSU7 to supply power for the BTS.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. GBFD-111202O&M of BTS Enumeration Type NO(NO), YES(YES) NO, YES None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PSUTOORECEIVETHRSH PS UtoO HO Receive Level Threshold BSC6900 SET GCELLHOIUO(Optional) Threshold of the receive level for triggering the handover of the PS services from the underlaid subcell to the overlaid subcell. None None Interval Type 0~63 0~63 None None 35 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PSUTURNINGOFFENABLE PSU Turning Off Enable BSC6900 SET BTSOTHPARA(Optional) Whether to enable intelligent shut-down of the PSU GBFD-111608PSU Smart Control Enumeration Type NO(NO), YES(YES) NO, YES None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PT Port Type BSC6900 SET ALMPORT(Mandatory) Port type of environment alarm MRFD-210304Faulty Management Enumeration Type BOOL(BOOL), VALUE(VALUE) BOOL, VALUE None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PT Port BSC6900 ADD SNTPSRVINFO(Mandatory) Number of the port that provides the time information on the SNTP server GBFD-111203O&M of BSC Interval Type 123~65534 123~65534 None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PT Cell reselect penalty time BSC6900 SET GCELLIDLEAD(Optional) Cell Reselect Penalty Time (PT) is used to ensure the safety and validity of cell reselection because it helps to avoid frequent cell reselection. For details, see GSM Rec. 05.08 and 04.08. GBFD-110402Basic Cell Re-selection Interval Type 0~31 0~31 s None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PT Subnet Protocol Type BSC6900 ADD NSE(Mandatory) Subnet protocol type. GBFD-119001Gb Interface Function Enumeration Type GB_OVER_FR(Gb over FR), GB_OVER_IP(Gb over IP) GB_OVER_FR, GB_OVER_IP None None None NSE None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
PT Port Type BSC6900 SET BTSENVALMPORT(Optional) Alarm port typeMRFD-210304Faulty Management Enumeration Type BOOL(BOOL), VALUE(VALUE) BOOL, VALUE None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PTCODE Line code BSC6900 SET E1T1(Optional) Line coding method None None Enumeration Type B8ZS(B8ZS), HDB3(HDB3), AMI(AMI), AMI_ZCS(AMI_ZCS) B8ZS, HDB3, AMI, AMI_ZCS None None None E1/T1 port None Read & Write Y BSC6900 Interrupt the service until negotiate successfully again. The line code must be consistent with that on the interconnected side. HDB3 (HDB3 code) and AMI (AMI code) are used for E1 ports. B8ZS (B8ZS code) and AMI_ZCS (AMI code) are used for T1 ports.
PTRXT Frame receive Structure BSC6900 SET E1T1(Optional) Receiving frame structure None None Enumeration Type E1_DOUBLE_FRAME(E1_DOUBLE_FRAME), E1_CRC4_MULTI_FRAME(E1_CRC4_MULTI_FRAME), T1_SUPER_FRAME(T1_SUPER_FRAME), T1_EXTENDED_SUPER_FRAME(T1_EXTENDED_SUPER_FRAME) E1_DOUBLE_FRAME, E1_CRC4_MULTI_FRAME, T1_SUPER_FRAME, T1_EXTENDED_SUPER_FRAME None None None E1/T1 port None Read & Write Y BSC6900 Interrupt the service until negotiate successfully again. The frame structure must be consistent with that on the interconnected side.
PTTXT Frame send Structure BSC6900 SET E1T1(Optional) Sending frame structure None None Enumeration Type E1_DOUBLE_FRAME(E1_DOUBLE_FRAME), E1_CRC4_MULTI_FRAME(E1_CRC4_MULTI_FRAME), T1_SUPER_FRAME(T1_SUPER_FRAME), T1_EXTENDED_SUPER_FRAME(T1_EXTENDED_SUPER_FRAME) E1_DOUBLE_FRAME, E1_CRC4_MULTI_FRAME, T1_SUPER_FRAME, T1_EXTENDED_SUPER_FRAME None None None E1/T1 port None Read & Write Y BSC6900 Interrupt the service until negotiate successfully again. The frame structure must be consistent with that on the interconnected side.
PTTYPE Frame Structure BSC6900 SET E1T1(Optional) Frame structureNone None Enumeration Type E1_DOUBLE_FRAME(E1_DOUBLE_FRAME), E1_CRC4_MULTI_FRAME(E1_CRC4_MULTI_FRAME), T1_SUPER_FRAME(T1_SUPER_FRAME), T1_EXTENDED_SUPER_FRAME(T1_EXTENDED_SUPER_FRAME) E1_DOUBLE_FRAME, E1_CRC4_MULTI_FRAME, T1_SUPER_FRAME, T1_EXTENDED_SUPER_FRAME None None E1_CRC4_MULTI_FRAME E1/T1 port None Read & Write Y BSC6900 Interrupt the service until negotiate successfully again. The frame structure must be consistent with that on the interconnected side.
PTUID HDLC Path Index In BTS BSC6900 ADD BTSABISHDLCPATH(Mandatory)ADD BTSBIND2HDLCPATH(Mandatory)ADD GTRXBIND2HDLCPATH(Mandatory) Number of a BTS HDLC path. It is unique in one [BTS]. GBFD-118401Abis Transmission Optimization Interval Type 0~15 0~15 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PTYPE Port type BSC6900 SET ETHPORT(Mandatory) Ethernet port type None None Enumeration Type FE, GE FE, GE None None None Ethernet port None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PTYPE Power System Type BSC6900 SET BTSAPMUBP(Optional) Power system type. When the PMU is installed on the rack, you can select the custom power system type.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. GBFD-111202O&M of BTS Enumeration Type APM100(APM100), APM200(APM200), APM30(APM30), PS4890(PS4890), EPS4815(EPS4815), SC48200~5||(SC48200)$$(SC48200)** CUSTOM(SC48200)** CUSTOM~100||()$$(CUSTOM) APM100, APM200, APM30, PS4890, EPS4815, SC48200, CUSTOM None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PubCert Certificate File Name BSC6900 SET CERTFILE(Optional) Name of the certificate file MRFD-210305Security Management String Type None 0~200 characters None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PV BTS Patch version BSC6900 SET BTSAUTODLDACTINFO(Optional) BTS patch No. for automatic BTS loading and activating GBFD-111202O&M of BTS String Type None 1~50 characters None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PV Patch Version BSC6900 LOD BTSPATCH(Mandatory)CON BTSPATCH(Mandatory) Number of the patch version GBFD-110703Enhanced Power Control Algorithm String Type None 1~50 characters None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PVCUSERATETIMER PVC Utilization Report Period Timer BSC6900 SET BSCPSSOFTPARA(Optional) Period timer of PVC utilization report. This timer is started during initialization. When the timer expires, the PVC utilization information is reported. GBFD-510002Gb Over FR Interval Type 1~65535 1~65535 ms None 500 BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PWD Private Key Password BSC6900 SET CERTFILE(Mandatory) Private key password MRFD-210305Security Management Password TypeNone 0~64 characters None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PWD Password BSC6900 ADD OP(Mandatory)DLD LICENSE(Mandatory)ULD LICENSE(Mandatory) Password. GBFD-111203MRFD-210305 O&M of BSCSecurity Management Password TypeNone 1~32 characters None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PWD User Password BSC6900 DLD BTSSW(Mandatory)DLD RETANTCFG(Mandatory)ULD BTSDEVFILE(Mandatory)DLD BTSPATCH(Mandatory)ULD BTSLOG(Mandatory) Password of the FTP server GBFD-110703Enhanced Power Control Algorithm Password TypeNone 1~32 characters None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PwdMinLen Minimum Password Length BSC6900 SET PWDPOLICY(Optional) Minimum length of the user password MRFD-210305Security Management Interval Type 6~32 6~32 characters None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PWL Power Level BSC6900 STR BTSTST(Mandatory) Power level GBFD-110703Enhanced Power Control Algorithm Interval Type 0~31 0~31 None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PWRBCDALLOWD Power Forecast Allowed BSC6900 SET GCELLPWRBASIC(Optional) Whether to allow active power control. If this parameter is set to YES, the system performs power forecast in the process of initial access assignment or service channel activation during intra-BSC handovers, and sends the forecast initial power information to the BTSs through channel activation messages. In this way, the MSs and BTSs can adjust the transmit power. If this parameter is set to NO, the system does not perform power forecast, and the MSs and BTSs choose the maximum transmit power. GBFD-117602Active Power Control Enumeration Type NO(No), YES(Yes), INVALID(Invalid) NO, YES, INVALID None None NO Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PWRCTRLOPTIMIZEDEN III Power Control Optimized Enable BSC6900 SET GCELLPWR3(Optional) Whether to enable the optimized power control algorithm III GBFD-117601HUAWEI III Power Control Algorithm Enumeration Type NO(No), YES(Yes)NO, YES None None NO Cell This parameter is valid only when "PWRCTRLSW" in "SET GCELLPWRBASIC" is set to PWR3. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PWRCTRLSW Power Control Switch BSC6900 SET GCELLPWRBASIC(Optional) Whether to enable power control algorithm II or power control algorithm III GBFD-110703Enhanced Power Control Algorithm Enumeration Type PWR2(Power control II), PWR3(Power controlIII) PWR2, PWR3 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PWRDIV Power Deviation BSC6900 SET GCELLCCACCESS(Optional) If a class 3 MS on the DCS1800 band does not receive the original power command after random access, the power that the MS uses is the MS maximum transmit power level plus the power calculated from the power deviation. For details, see GSM Rec. 05.08. GBFD-111003Radio Common Channel Management Interval Type 0~3 0~3 None None 1 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PWRDIVIND Power Deviation Indication BSC6900 SET GCELLCCACCESS(Optional) The MS does not receive the original power command after random access. This parameter indicates whether the power deviation is added to the class 3 MS on the DCS1800 band on the basis of the maximum MS transmit power. GBFD-111003Radio Common Channel Management Enumeration Type NO(No), YES(Yes)NO, YES None None YES Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PWRLOCATION Location Group Power Switch BSC6900 SET GCELLSOFT(Optional) Whether to enable the power amplifier for all location groups. 0x01 indicates that the TRX power amplifier is enabled for all location groups. 0x00 indicates that the TRX power amplifier is enabled for the current location group. GBFD-510104Multi-site Cell Enumeration Type OnlyCurPwrLoc(Only Current Working Location TRXes be Turned On), ALLPwrLoc(All Location TRXes be Turned On) OnlyCurPwrLoc, ALLPwrLoc None None ALLPwrLoc Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PWRMODE Power Class BSC6900 ADD BTSBRDCAP(Mandatory)ADD BTSRXUBRD(Optional) Power mode. GBFD-111202O&M of BTS Enumeration Type CLASS0(Class0), CLASS1(Class1), CLASS2(Class2) CLASS0, CLASS1, CLASS2 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PWROFFPROTECTSTARTTIME Power-off Protect Start Time BSC6900 SET BTSBAKPWR(Optional) This parameter is valid in the BTSs that supports the backup power decrease function. GBFD-111605Active Backup Power Control Interval Type 0~720 0~720 min None 5 BTS This parameter is valid only when the cell parameter "BAKPWRSAVMETHOD" is set to BYPWR. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PWRPRIORALLOW Power Priority Allowed BSC6900 SET GCELLCHMGAD(Optional) Whether to use carriers with better power saving performance. When this parameter is set to YES, carriers with better power saving performance are selected preferentially. GBFD-111005Enhanced Channel Assignment Algorithm Enumeration Type NO(No), YES(Yes)NO, YES None None NO Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PWRSPNR Power Finetune BSC6900 SET GTRXDEV(Optional) Find adjustment of the TRX power. During fine static adjustment of the TRX power, the BSC adjusts the TRX power at a step of 0.2 dB. In certain scenarios, for example, when the TRX contains a combination of tributaries, the TRX has varying losses. In addition, the power difference before and after the power output may not be an integral multiple of 2 dB. Thus, adjusting the power at a step of 2 dB may not obtain the cabinet-top output power. As a result, the TRX output power may differ from the cabinet-top output power. This parameter helps to adjust the cabinet-top output power at a smaller step. MRFD-210301Configuration Management Enumeration Type DB0(0.0dB), DB2(-0.2dB), DB4(-0.4dB), DB6(-0.6dB), DB8(-0.8dB), DB10(-1.0dB), DB12(-1.2dB), DB14(-1.4dB), DB16(-1.6dB), DB18(-1.8dB), Default(Default) DB0, DB2, DB4, DB6, DB8, DB10, DB12, DB14, DB16, DB18, Default None None None TRX None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PwrSwitchA ANT_A ALD Power Switch BSC6900 SET BTSRXUBP(Optional) When the ANT_A tributary antenna power switch is ON, it is allowed to configure related parameters of the ANT_A tributary. GBFD-111202O&M of BTS Enumeration Type OFF(OFF), ON(ON) OFF, ON None OFF OFF BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PwrSwitchB ANT_B ALD Power Switch BSC6900 SET BTSRXUBP(Optional) When the ANT_B tributary antenna power switch is ON, it is allowed to configure related parameters of the ANT_B tributary. GBFD-111202O&M of BTS Enumeration Type OFF(OFF), ON(ON) OFF, ON None OFF OFF BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
PwrSwitchRET RET ALD Power Switch BSC6900 SET BTSRXUBP(Optional) When the RET tributary antenna power switch is ON, it is allowed to configure related parameters of the RET tributary. GBFD-111202O&M of BTS Enumeration Type OFF(OFF), ON(ON) OFF, ON None OFF OFF BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
Q0MINDSCP Min DSCP of queue 0 BSC6900 SET QUEUEMAP(Optional) Minimum DSCP of queue 0. The IP packets with DSCP in a relation that "Min DSCP of queue 0" <= DSCP <= 63 is added to queue 0. None None Interval Type 0~63 0~63 None None None Port queue None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The transmission priority of the service is affected if the queue DSCP value of the port is modified.
Q1MINDSCP Min DSCP of queue 1 BSC6900 SET QUEUEMAP(Optional) Minimum DSCP of queue 1. The IP packets with DSCP in a relation that "Min DSCP of queue 1" <= DSCP < "Min DSCP of queue 0" is added to queue 1. None None Interval Type 0~63 0~63 None None None Port queue None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The transmission priority of the service is affected if the queue DSCP value of the port is modified.
Q2MINDSCP Min DSCP of queue 2 BSC6900 SET QUEUEMAP(Optional) Minimum DSCP of queue 2. The IP packets with DSCP in a relation that "Min DSCP of queue 2" <= DSCP < "Min DSCP of queue 1" is added to queue 2. None None Interval Type 0~63 0~63 None None None Port queue None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The transmission priority of the service is affected if the queue DSCP value of the port is modified.
Q3MINDSCP Min DSCP of queue 3 BSC6900 SET QUEUEMAP(Optional) Minimum DSCP of queue 3. The IP packets with DSCP in a relation that "Min DSCP of queue 3" <= DSCP < "Min DSCP of queue 2" is added to queue 3. None None Interval Type 0~63 0~63 None None None Port queue None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The transmission priority of the service is affected if the queue DSCP value of the port is modified.
Q4MINDSCP Min DSCP of queue 4 BSC6900 SET QUEUEMAP(Optional) Minimum DSCP of queue 4. The IP packets with DSCP in a relation that "Min DSCP of queue 4" <= DSCP < "Min DSCP of queue 3" is added to queue 4. None None Interval Type 0~63 0~63 None None None Port queue None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The transmission priority of the service is affected if the queue DSCP value of the port is modified.
QAAL2VER Qaal2 Protocol Version BSC6900 ADD ADJNODE(Optional) Function set of the adjacent node supported by local BSC. When the parameter is set to CS1, it indicates that the local BSC is interconnected to the adjacent node by using the CS1 protocol version. When the parameter is set to CS1, it indicates that the local BSC is interconnected to the adjacent node by using the CS2 protocol version. The CS2 protocol version is backward compatible with the CS1. By default, the parameter is set to CS2. When the peer is not compatible with the local CS2 messages (the peer does not process the compatible domain according to protocol requirements), the protocol version is set to CS1. None None Enumeration Type CS1(CS1 Version), CS2(CS2 Version) CS1, CS2 None CS2 CS2 Adjacent node When the value of "NODET" in "ADD ADJNODE" is set to IUB, IUR, or IUCS, and the value of "IsROOTNODE" in "ADD ADJNODE" is set to YES, or the value of "NODET" in "ADD ADJNODE" is set to UNI_AAL2SWITCH or NNI_AAL2SWITCH, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved When the parameter is set to CS1, it indicates that the local RNC is interconnected to the adjacent node by using the CS1 protocol version. When the parameter is set to CS2, it indicates that the local RNC is interconnected to the adjacent node by using the CS2 protocol version. The CS2 protocol version is backward compatible with the CS1. By default, the parameter is set to CS2. When the peer is not compatible with the local CS2 messages (the peer does not process the compatible domain according to protocol requirements), the protocol version is set to CS1.
QCI Qsearch C Initial BSC6900 SET GCELLCCUTRANSYS(Optional) Threshold of the signal level for cell reselection in connection mode before "Qsearch C" is obtained GBFD-114301GBFD-114302 GSM/WCDMA InteroperabilityGSM/TD-SCDMA Interoperability Enumeration Type Use_Qsearch_I(Use Qsearch_I), Always(Always) Use_Qsearch_I, Always None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
QCKMVHOEN MS Fast Moving HO Allowed BSC6900 SET GCELLHOBASIC(Optional) Whether to enable the fast moving micro-cell handover algorithm. The fast moving micro-cell handover algorithm enables fast moving MSs to switch over to macro-cells, thus reducing the handover times. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Enumeration Type NO(No), YES(Yes)NO, YES None None Set this parameter to YES only in special scenarios such as highways. Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
QCKSTATCNT MS Fast-moving Watch Cells BSC6900 SET GCELLHOAD(Optional) This parameter is used in the P/N criteria decision: If an MS quickly passes through N out of P micro-cells lately, the BSC enables the fast moving micro-cell handover algorithm. This parameter corresponds to the N in the P/N criteria. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 1~10 1~10 None None 3 Cell This parameter is valid only when "QCKMVHOEN" in "SET GCELLHOBASIC" is set to YES. The following condition must be met: "QCKSTATCNT" >= "QCKTRUECNT". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
QCKTIMETH MS Fast-moving Time Threshold BSC6900 SET GCELLHOAD(Optional) A time threshold determined based on the radius of a cell and the moving speed of an MS. If the MS crosses the cell in a time period shorter than this threshold, the BSC concludes that the MS quickly passes through the cell. Otherwise, it concludes that the MS slowly passes the cell. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 0~255 0~255 s None 15 Cell This parameter is valid only when "QCKMVHOEN" in "SET GCELLHOBASIC" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
QCKTRUECNT MS Fast-moving Valid Cells BSC6900 SET GCELLHOAD(Optional) This parameter is used in the P/N criteria decision: If an MS quickly passes through N out of P micro-cells lately, the BSC enables the fast moving micro-cell handover algorithm. This parameter corresponds to the P in the P/N criteria. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 1~10 1~10 None None 2 Cell This parameter is valid only when "QCKMVHOEN" in "SET GCELLHOBASIC" is set to YES. The following condition must be met: "QCKSTATCNT" >= "QCKTRUECNT". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
QI Qsearch I BSC6900 SET GCELLCCUTRANSYS(Optional) Level threshold for cell reselection in idle mode. In idle mode, if the signal level in the serving cell is below [0, 7] or above [8, 15], the MS starts to search for 3G cells.For example, if this parameter is set to 5 and the signal level of the serving cell is lower than 5, the MS starts to search for 3G cells. If this parameter is set to 10 and the signal level of the serving cell is higher than 10, the MS starts to search for 3G cells. The value of this parameter corresponds to the following decibel value:0: -98 dBm1: -94 dBm2: -90 dBm3: -86 dBm4: -82 dBm5: -78 dBm6: -74 dBm7: (always), that is, the MS keeps searching for 3G cells8: -78 dBm9: -74 dBm10: -70 dBm11: -66 dBm12: -62 dBm13: -58 dBm14: -54 dBm15: (never), that is, the MS does not search for 3G cells GBFD-114301GBFD-114302 GSM/WCDMA InteroperabilityGSM/TD-SCDMA Interoperability Interval Type 0~15 0~15 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
QLENSD Filter Length for TCH Qual. BSC6900 SET GCELLCHMGAD(Optional) For the purpose of accurately reflecting the radio environment of a network, filtering is performed on the measured values in several consecutive measurement reports. This parameter indicates the number of measurement reports used for the filtering of the signal quality on service or data channels. This parameter is used to determine whether interferences exist on channels. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 1~32 1~32, step:480 for TCH and 470 for SDCCH ms None 6 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
QLENSI Filter Length for SDCCH Qual. BSC6900 SET GCELLCHMGAD(Optional) For the purpose of accurately reflecting the radio environment of a network, filtering is performed on the measured values in several consecutive measurement reports. This parameter indicates the number of measurement reports used for the filtering of the signal quality on signaling channels. This parameter is used to determine whether interferences exist on channels. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 1~32 1~32, step:480 for TCH and 470 for SDCCH ms None 2 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
QOSOPT Support QoS Optimize BSC6900 SET GCELLPSOTHERPARA(Optional) Whether to support QoC optimization. The GSN equipment for the GPRS provides flexible QoS mechanisms for different subscribers. The QoS level is also set during subscription. The QoS control parameters include: service priority, reliability level, delay level, and data throughput level. During QoS negotiation, the MS can apply for one value for each QoS attribute. When receiving the request from the MS, the network must allocate a QoS level to each attribute for each QoS document. The network provides related resources for the negotiated QoS document. GBFD-119902QoS ARP&THP Enumeration Type NO(Not Support), YES(Support) NO, YES None None NO Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
QP Qsearch P BSC6900 SET GCELLCCUTRANSYS(Optional) Threshold of the signal level for cell reselection in packet transfer mode.In packet transfer mode, if the signal level in the serving cell is below [0, 7] or above [8, 15], the MS starts to search for 3G cells.For example, if this parameter is set to 5 and the signal level of the serving cell is lower than 5, the MS starts to search for 3G cells. If this parameter is set to 10 and the signal level of the serving cell is higher than 10, the MS starts to search for 3G cells. The value of this parameter corresponds to the following decibel value:0: -98 dBm1: -94 dBm...6: -74 dBm7: (always)8: -78 dBm9: -74 dBm...14: -54 dBm15: (never) GBFD-114301GBFD-114302 GSM/WCDMA InteroperabilityGSM/TD-SCDMA Interoperability Interval Type 0~15 0~15 None None 15 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
QSEARCHC Qsearch C BSC6900 SET GCELLCCUTRANSYS(Optional) In connection mode, if the signal level is below (0-7) or above (8-15), the MS starts to search for 3G cells. GBFD-114301GBFD-114302 GSM/WCDMA InteroperabilityGSM/TD-SCDMA Interoperability Interval Type 0~15 0~15 None None 15 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
QTRUCHANMANGSWITCH QTRU Signal Merge Avoid Switch BSC6900 SET GCELLSOFT(Optional) This parameter is used to avoid allocating the calls whose signal strengths differ greatly to the same timeslot. The BSC measures the signal merge conditions on each timeslot every 0.5 seconds. If the difference between the highest signal strength and the lowest signal strength on a timeslot is greater than the value of "UL Signal Strength Difference Threshold", it regards it as a signal merge event. If N signal merge events are consecutively detected among P times of measurements, the forcible intra-cell handover is triggered to switch the call with the highest signal strength to another timeslot in the cell.Here, N indicates "UL Signal Strength Difference Detections", P indicates "UL Signal Strength Difference Maintains". GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Enumeration Type NO(Close), YES(Open) NO, YES None None NO Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
QTRUDNPWRLASTTIME Qtru Down Power Inadequate Last Time BSC6900 SET GCELLCHMGAD(Optional) The P/N criteria is used to determine low downlink power for multi-density carriers. If the downlink power of a multi-density carrier remains low during a consecutive P seconds out of N seconds, the downlink power of the multi-density carrier is considered low. This parameter corresponds to the P in the P/N criteria. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 1~16 1~16 s None 3 Cell This parameter is valid only when "QTRUPWRSHARE" is not set to NONE. The following condition must be met: "QTRUDNPWRSTATTIME" >= "QTRUDNPWRLASTTIME". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
QTRUDNPWRSTATTIME Qtru Down Power Inadequate Stat Time BSC6900 SET GCELLCHMGAD(Optional) The P/N criteria is used to determine low downlink power for multi-density carriers. If the downlink power of a multi-density carrier remains low during a consecutive P seconds out of N seconds, the downlink power of the multi-density carrier is considered low. This parameter corresponds to the N in the P/N criteria. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 1~16 1~16 s None 5 Cell This parameter is valid only when "QTRUPWRSHARE" is not set to NONE. The following condition must be met: "QTRUDNPWRSTATTIME" >= "QTRUDNPWRLASTTIME". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
QTRUPWRSHARE Multi-Density Trx Power Sharing BSC6900 SET GCELLCHMGAD(Optional) Whether to use the statistical multiplexing algorithm for multi-density power GBFD-111005Enhanced Channel Assignment Algorithm Enumeration Type NONE(None), DYNAMIC(Dynamic power sharing) NONE, DYNAMIC None None NONE Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
QUALOFFTIMES Qualified Times for Off BSC6900 SET BTSAIRCON(Optional) Maximum number of times that the BTS finds that the air conditioner needs to be switched off. If the number of times that the BTS finds that the air conditioner needs to be switched off in the "CHKOFFTIMES" checks reaches this parameter, the BTS switches off the air conditioner. GBFD-111202O&M of BTS Interval Type 3~20 3~20 None None 6 BTS This parameter must be equal to or greater than 0.6x"CHKOFFTIMES" and equal to or less than "CHKOFFTIMES". Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter is supported only by the BTS3012A and BTS3006A.
QUALONTIMES Qualified Times for On BSC6900 SET BTSAIRCON(Optional) Maximum number of times that the BTS finds that the air conditioner needs to be switched on. If the number of times that the BTS finds that the air conditioner needs to be switched on in the "CHKONTIMES" checks reaches this parameter, the BTS switches on the air conditioner. GBFD-111202O&M of BTS Interval Type 3~20 3~20 None None 6 BTS This parameter must be equal to or greater than 0.6x"CHKONTIMES" and equal to or less than "CHKONTIMES". Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter is supported only by the BTS3012A and BTS3006A.
QUALSTEP MAX Down Adj. PC Value by Qual. BSC6900 SET GCELLPWR2(Optional) Step of downward power adjustment according to the quality of the received signals. GBFD-110703Enhanced Power Control Algorithm Interval Type 0~4 0~4 dB None 2 Cell This parameter is valid when "PWRCTRLSW" in the "SET GCELLPWRBASIC" command is set to PWR2. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
QUERYCMAFTERINBSCHO Query Classmark after In-BSC HO Enabled BSC6900 SET GCELLSOFT(Optional) Whether to query the classmark of the call in an incoming BSC handover GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Enumeration Type NO(No), YES(Yes)NO, YES None None NO Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
QUICKHOEN Quick handover enable BSC6900 SET GCELLHOBASIC(Optional) Whether to allow the fast handover algorithm GBFD-510102Fast Move Handover Enumeration Type NO(No), YES(Yes)NO, YES None None NO Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
R0AuxDev SubRack0 Auxiliary Equipment BSC6900 SET BTSAUXEQP(Optional) Auxiliary devices of rack 0. This parameter contains eight bits.The eight bits, from the most significant bit to the least significant bit, indicate whether to install a voltage stabilizer, internal battery, transmission power supply, temperature control unit, auxiliary device 5, auxiliary device 6, auxiliary device 7, and auxiliary device 8. When a bit is set to 1, the relevant auxiliary device is installed. When a bit is set to 0, the relevant auxiliary device is not installed. For example, if this parameter is set to 10000000, rack 0 is configured with an auxiliary voltage stabilizer. GBFD-111202O&M of BTS Bit Field Type AU0, AU1, AU2, AU3, AU4, AU5, AU6, AU7 AU0, AU1, AU2, AU3, AU4, AU5, AU6, AU7 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter is supported only by the BTS3012A.
R0BatAllow SubRack0 Storage Battery Config Permit BSC6900 SET BTSBAT(Optional) Whether to configure a battery rack for rack 0 GBFD-111202O&M of BTS Enumeration Type NO(No), YES(Yes)NO, YES None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter is supported only by the BTS3012A and BTS3006A.
R0BatCap SubRack0 Storage Battery Capacity BSC6900 SET BTSBAT(Mandatory) Capacity of the battery rack configured for rack 0 GBFD-111202O&M of BTS Enumeration Type INSIDE_100AH(100AH Inside Storage Battery), INSIDE_50AH(50AH Inside Storage Battery), OUTSIDE_300AH(300AH Outside Storage Battery), OUTSIDE_400AH(400AH Outside Storage Battery), OUTSIDE_500AH(500AH Outside Storage Battery), OUTSIDE_650AH(650AH Outside Storage Battery), OUTSIDE_200AH(200AH Outside Storage Battery) INSIDE_100AH, INSIDE_50AH, OUTSIDE_300AH, OUTSIDE_400AH, OUTSIDE_500AH, OUTSIDE_650AH, OUTSIDE_200AH None None None BTS This parameter is valid only when "R0BatAllow" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter is supported only by the BTS3012A and BTS3006A.
R0BatCoeff SubRack0 Storage Battery Coefficient BSC6900 SET BTSBAT(Mandatory) Ratio of the maximum charging current of the battery pack configured for rack 0 to the capacity of the battery pack. For example, assume that the battery pack has a capacity of 200 AH. If this parameter is set to 0.15C, the maximum charging current of the battery pack is 30 A (= 0.15 x 200). GBFD-111202O&M of BTS Enumeration Type 007C(0.07C), 010C(0.10C), 015C(0.15C) 007C, 010C, 015C None None 015C BTS This parameter is valid only when "R0BatAllow" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter is supported only by the BTS3012A and BTS3006A.
R0BatType SubRack0 Storage Battery Type BSC6900 SET BTSBAT(Mandatory) Type of the battery rack configured for rack 0 GBFD-111202O&M of BTS Enumeration Type INSIDE_BATTERY(Inside Storage Battery), OUTSIDE_BATTERY(Outside Storage Battery) INSIDE_BATTERY, OUTSIDE_BATTERY None None None BTS This parameter is valid only when "R0BatAllow" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter is supported only by the BTS3012A and BTS3006A.
R1AuxDev SubRack1 Auxiliary Equipment BSC6900 SET BTSAUXEQP(Optional) Auxiliary devices of rack 1. This parameter contains eight bits.The eight bits, from the most significant bit to the least significant bit, indicate whether to install a voltage stabilizer, internal battery, transmission power supply, temperature control unit, auxiliary device 5, auxiliary device 6, auxiliary device 7, and auxiliary device 8. When a bit is set to 1, the relevant auxiliary device is installed. When a bit is set to 0, the relevant auxiliary device is not installed. For example, if this parameter is set to 10000000, rack 1 is configured with an auxiliary voltage stabilizer. GBFD-111202O&M of BTS Bit Field Type AU0, AU1, AU2, AU3, AU4, AU5, AU6, AU7 AU0, AU1, AU2, AU3, AU4, AU5, AU6, AU7 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter is supported only by the BTS3012A.
R1BatAllow SubRack1 Storage Battery Config Permit BSC6900 SET BTSBAT(Optional) Whether to configure a battery rack for rack 1 GBFD-111202O&M of BTS Enumeration Type NO(No), YES(Yes)NO, YES None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter is supported only by the BTS3012A and BTS3006A.
R1BatCap SubRack1 Storage Battery Capacity BSC6900 SET BTSBAT(Mandatory) Capacity of the battery rack configured for rack 1 GBFD-111202O&M of BTS Enumeration Type INSIDE_100AH(100AH Inside Storage Battery), INSIDE_50AH(50AH Inside Storage Battery), OUTSIDE_300AH(300AH Outside Storage Battery), OUTSIDE_400AH(400AH Outside Storage Battery), OUTSIDE_500AH(500AH Outside Storage Battery), OUTSIDE_650AH(650AH Outside Storage Battery), OUTSIDE_200AH(200AH Outside Storage Battery) INSIDE_100AH, INSIDE_50AH, OUTSIDE_300AH, OUTSIDE_400AH, OUTSIDE_500AH, OUTSIDE_650AH, OUTSIDE_200AH None None None BTS This parameter is valid only when "R1BatAllow" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter is supported only by the BTS3012A and BTS3006A.
R1BatCoeff SubRack1 Storage Battery Coefficient BSC6900 SET BTSBAT(Mandatory) Ratio of the maximum charging current of the battery pack configured for rack 1 to the capacity of the battery pack. For example, assume that the battery pack has a capacity of 200 AH. If this parameter is set to 0.15C, the maximum charging current of the battery pack is 30 A (= 0.15 x 200). GBFD-111202O&M of BTS Enumeration Type 007C(0.07C), 010C(0.10C), 015C(0.15C) 007C, 010C, 015C None None None BTS This parameter is valid only when "R1BatAllow" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter is supported only by the BTS3012A and BTS3006A.
R1BatType SubRack1 Storage Battery Type BSC6900 SET BTSBAT(Mandatory) Type of the battery rack configured for rack 1 GBFD-111202O&M of BTS Enumeration Type INSIDE_BATTERY(Inside Storage Battery), OUTSIDE_BATTERY(Outside Storage Battery) INSIDE_BATTERY, OUTSIDE_BATTERY None None None BTS This parameter is valid only when "R1BatAllow" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter is supported only by the BTS3012A and BTS3006A.
R2AuxDev SubRack2 Auxiliary Equipment BSC6900 SET BTSAUXEQP(Optional) Auxiliary devices of rack 2. This parameter contains eight bits.The eight bits, from the most significant bit to the least significant bit, indicate whether to install a voltage stabilizer, internal battery, transmission power supply, temperature control unit, auxiliary device 5, auxiliary device 6, auxiliary device 7, and auxiliary device 8. When a bit is set to 1, the relevant auxiliary device is installed. When a bit is set to 0, the relevant auxiliary device is not installed. For example, if this parameter is set to 10000000, rack 2 is configured with an auxiliary voltage stabilizer. GBFD-111202O&M of BTS Bit Field Type AU0, AU1, AU2, AU3, AU4, AU5, AU6, AU7 AU0, AU1, AU2, AU3, AU4, AU5, AU6, AU7 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter is supported only by the BTS3012A.
R2BatAllow SubRack2 Storage Battery Config Permit BSC6900 SET BTSBAT(Optional) Whether to configure a battery rack for rack 2 GBFD-111202O&M of BTS Enumeration Type NO(No), YES(Yes)NO, YES None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter is supported only by the BTS3012A and BTS3006A.
R2BatCap SubRack2 Storage Battery Capacity BSC6900 SET BTSBAT(Mandatory) Capacity of the battery rack configured for rack 2 GBFD-111202O&M of BTS Enumeration Type INSIDE_100AH(100AH Inside Storage Battery), INSIDE_50AH(50AH Inside Storage Battery), OUTSIDE_300AH(300AH Outside Storage Battery), OUTSIDE_400AH(400AH Outside Storage Battery), OUTSIDE_500AH(500AH Outside Storage Battery), OUTSIDE_650AH(650AH Outside Storage Battery), OUTSIDE_200AH(200AH Outside Storage Battery) INSIDE_100AH, INSIDE_50AH, OUTSIDE_300AH, OUTSIDE_400AH, OUTSIDE_500AH, OUTSIDE_650AH, OUTSIDE_200AH None None None BTS This parameter is valid only when "R2BatAllow" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter is supported only by the BTS3012A and BTS3006A.
R2BatCoeff SubRack2 Storage Battery Coefficient BSC6900 SET BTSBAT(Mandatory) Ratio of the maximum charging current of the battery pack configured for rack 2 to the capacity of the battery pack. For example, assume that the battery pack has a capacity of 200 AH. If this parameter is set to 0.15C, the maximum charging current of the battery pack is 30 A (= 0.15 x 200). GBFD-111202O&M of BTS Enumeration Type 007C(0.07C), 010C(0.10C), 015C(0.15C) 007C, 010C, 015C None None None BTS This parameter is valid only when "R2BatAllow" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter is supported only by the BTS3012A and BTS3006A.
R2BatType SubRack2 Storage Battery Type BSC6900 SET BTSBAT(Mandatory) Type of the battery rack configured for rack 2 GBFD-111202O&M of BTS Enumeration Type INSIDE_BATTERY(Inside Storage Battery), OUTSIDE_BATTERY(Outside Storage Battery) INSIDE_BATTERY, OUTSIDE_BATTERY None None None BTS This parameter is valid only when "R2BatAllow" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter is supported only by the BTS3012A and BTS3006A.
RA RAC BSC6900 ADD GEXT2GCELL(Optional) The NS performs location management based on routing areas during GPRS packet services. Each routing area has a routing area identifier, which is broadcast as a system message. MRFD-210301Configuration Management Interval Type 0~255 0~255 None None 0 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RA route area BSC6900 ADD GEXT3GCELL(Optional) The NS performs location management based on routing areas during GPRS packet services. Each routing area has a routing area identifier. MRFD-210301Configuration Management Interval Type 0~255 0~255 None 0 0 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RA Routing Area BSC6900 SET GCELLGPRS(Optional) Identifies the routing area of the current cell. GBFD-114101GPRS Interval Type 0~255 0~255 None None None Cell This parameter is valid only when "GPRS" is set to SupportAsInnPcu. Read & Write Y Cell Less than 5 minutes None
RA Route area BSC6900 ADD GCELLQUICKSETUP(Optional)SET BTSAUTOPLANCFG(Optional) Route area of the current cell GBFD-510701Compact BTS Automatic Configuration and Planning Interval Type 0~255 0~255 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RA1 Route area BSC6900 SET BTSAUTOPLANCFG(Optional) Route area of the current cell GBFD-510702Compact BTS Automatic Capacity Planning Interval Type 0~255 0~255 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RACHACCLEV CS RACH Min. Access Level BSC6900 SET GCELLCCACCESS(Optional) Minimum access level of the random access channel (RACH) in the CS domain GBFD-111003Radio Common Channel Management Interval Type -121~-109 -121~-109 dBm None -115 Cell The value of this parameter must be smaller than "RACH Busy Threshold" in the "SET GCELLCCBASIC" command. Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter should be set on the basis of the actual receiver sensitivity of the BTS and the minimum access level of the MS to avoid the situation where a call cannot be made even though there are signals detected.
RACHACCLEV CS RACH Min. Access Level BSC6900 SET GCELLRACHCCLEV(Optional) Level threshold of the MS random access in the PS domain. For the BTS3X and the double-transceiver BTSs, this parameter settings affect the MS access. If the receive level of the RACH burst is lower than RACH Min.Access Level, the BTS regards this access as an invalid one and no decoding is performed. If the receive level of the RACH burst is higher than RACH Min. Access Level, the BTS considers that an access request exists on this timeslot, and determines together with the value of Random Access Error Threshold whether the RACH access is valid. GBFD-111003Radio Common Channel Management Interval Type -121~-47 -121~-47 dBm None -109 Cell The value of this parameter must be smaller than "RACH Busy Threshold" in the "SET GCELLCCBASIC" command. Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter should be set on the basis of the actual receiver sensitivity of the BTS and the minimum access level of the MS to avoid the situation where a call cannot be made even though there are signals detected.
RACHBUSYTHRED RACH Busy Threshold BSC6900 SET GCELLCCBASIC(Optional) Level threshold of the MS random access for the BTS to determine the RACH busy state. When the receive level of the random access burst timeslot is greater than this threshold, the BTS considers that the timeslot is busy. GBFD-111003Radio Common Channel Management Interval Type 0~63 0~63 dB None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved For the BTS3X series and double-transceiver BTSs, this parameter does not affect MS access but affects the reporting of CCCH_LOAD_IND. If the level received by the BCCH on the network side is greater than the RACH Busy Threshold, the CCCH_LOAD_IND is counted once whether the decoding is successful. The RACH whose level is lower than the RACH Busy Threshold and whose decoding is successful is also counted. The measurement period is the Average RACH Load Timeslot Number.If the value of this parameter is too low, the BTS easily considers that the RACH timeslot is busy and reports overload messages to the BSC. If the value is too high, the BTS cannot determine the status of the RACH timeslot correctly.The settings of the BTS312, BTS3001C, BTS3001CP, BTS3002C, and double-transceiver BTS must be consistent with the meaning and requirement of the BTS30.
RACHLDAVERSLOT Average RACH Load Timeslot Number BSC6900 SET GCELLCCCH(Optional) Number of RACH burst timeslots in a RACH load measurement.The value of this parameter indicates the interval during which the BSC determines whether an RACH timeslot is busy. For details, see GSM Rec. 08.58. GBFD-111003Radio Common Channel Management Interval Type 0~65535 0~65535 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RACJACCLEV CS Min.Access Level BSC6900 ADD BTSLOCGRP(Optional) Minimum voltage level for accessing CS services of the location group GBFD-510104Multi-site Cell Interval Type -121~-47 -121~-47 dBm None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RACOLOR Routing Area Color Code BSC6900 SET GCELLPSBASE(Optional) Routing area color code of the GPRS cell. GBFD-114101GPRS Interval Type 0~7 0~7 None None 1 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RANDACCESSRETRY Allow MS to Access to Another Cell BSC6900 SET GCELLRESELECTPARA(Optional) Whether to allow the MS to access another cell. GBFD-114101GPRS Enumeration Type NO(No), YES(Yes)NO, YES None None YES Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RANERRTHRED Random Access Error Threshold BSC6900 SET GCELLCCACCESS(Optional) Correlation threshold of the training sequence for the random access.As defined in the GSM recommendation, the system can determine whether the received signals are random access signals of the MS and calculate the TA value by checking the correlation of the 41-bit training sequence.RandomAccess Error Threshold Number of Correct Bits in the 41-Bit Training Sequence90-100 33101-120 34121-140 35141-160 36161-175 37176-195 38196-221 39222-243 40244-250 410-89 or 251-255 38. GBFD-111003Radio Common Channel Management Interval Type 0~255 0~255 None None 225 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RARESELECTHYST Accessorial Hysteresis of Cell Selection BSC6900 SET GCELLRESELECTPARA(Optional) Hysteresis of cell selection in different routing area. When a standby or ready MS starts cell reselection, if the original cell and the target cell are in the different routing area, the signal level of the neighboring cell must be greater that of the current cell. Their difference must be larger than the specified hysteresis. Otherwise the MS cannot start cell reselection. The larger the hysteresis of GPRS cell selection, the harder to start cell reselection. GBFD-114101GPRS Enumeration Type 0dB(0dB), 2dB(2dB), 4dB(4dB), 6dB(6dB), 8dB(8dB), 10dB(10dB), 12dB(12dB), 14dB(14dB), nouse(no use) 0dB, 2dB, 4dB, 6dB, 8dB, 10dB, 12dB, 14dB, no use dB None 2dB Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RATE Fault cell rate BSC6900 SET FACFG(Mandatory) Fault cell rate when restore interface board to judge fault port. MRFD-210304Faulty Management Interval Type 0~100 0~100 None None None None None Read & Write Not involved Not involved Not involved None
RATE Rate BSC6900 SET BTSETHPORT(Optional) Port rate of the IP interface board GBFD-118601Abis over IP Enumeration Type 10M(10M), 100M(100M), AUTO(Auto) 10M, 100M, AUTO None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RATECTRLSW AMR rate control switch BSC6900 SET GCELLCCAMR(Optional) Switch for controlling the AMR rate. Value 0 indicates that C/I is used to control the AMR rate. Value 1 indicates that BER is used to control the AMR rate. GBFD-115506AMR Coding Rate Threshold Adaptive Adjustment Enumeration Type ALG1(Algorithm I), ALG2(Algorithm II), NONE(None) ALG1, ALG2, NONE None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved If this parameter is set to Algorithm I, the BTS performs AMR rate adaptation according to the C/I value.If this parameter is set to Algorithm II, the BTS performs AMR rate adaptation according to the BER value. Algorithm II is valid only for the EMR.If this parameter is set to None, the AMR rate adaptation algorithm is not enabled, and a fixed coding rate is used.
RATSCCHENABLED Is Ratscch Function Enabled BSC6900 SET GCELLCCAMR(Optional) This parameter specifies whether the RATSCCH function is enabled during the call establishment procedure. GBFD-115506AMR Coding Rate Threshold Adaptive Adjustment Enumeration Type DISABLE(Disable), ENABLE(Enable) DISABLE, ENABLE None DISABLE DISABLE Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RAWMRSAMPLE Raw MR Sample Ratio BSC6900 SET GMRCTRL(Optional) Original measurement report sampling rate (for each call, one out of four measurement reports is collected) GBFD-110801Processing of Measurement Report Interval Type 1~255 1~255 None None 4 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RBPTYPE Type of Rollback Point BSC6900 BEG FORWARD(Mandatory) LASTRBP indicates the last rollback point. The system automatically takes the position where the current configuration command is executed as the rollback point, and the user does not need to specify a rollback point. APPOINTRBP indicates the rollback point specified by the user. MRFD-210301Configuration Management Enumeration Type LASTRBP(last rollbackpoint), APPOINTRBP(appointed rollbackpoint) LASTRBP, APPOINTRBP None None None BSC6900None Read & Write Not involved Not involved Not involved None
RCDT Result Recording Type BSC6900 RUN BATCHFILE(Optional) Type of recording the execution result1. REC_ALL: indicating that the execution results of all the commands are recorded no matter whether the commands are executed successfully.2. REC_ERR: indicating that only the execution results of failed commands are recorded.3. REC_NON: indicating that the execution results of all the commands are not recorded no matter whether the commands are executed successfully. GBFD-111203O&M of BSC Enumeration Type REC_ALL(Record all), REC_ERR(Record errors), REC_NON(Record none) REC_ALL, REC_ERR, REC_NON None None REC_ALL RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RCN Chain No. BSC6900 ADD BTSRXUCHAIN(Mandatory)SET BTSBREAKPOINT(Mandatory)SPT BTSRXUCHAIN(Mandatory) Number of the RXU chain or ring. The value scope is 0~11 for Non-SRAN BTS and 0~249 for SRAN BTS. The RXU chain No. is unique in the same BTS. A maximum of 12 RXU chains can be configured in one BTS. GBFD-111202O&M of BTS Interval Type 0~249 0~249 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RCN1 First RXU Chain No. BSC6900 CBN BTSRXUCHAIN(Mandatory) The first RXU chain number when combining two RXU chains to be one RXU ring. GBFD-111202O&M of BTS Interval Type 0~249 0~249 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RCN2 Second RXU Chain No. BSC6900 CBN BTSRXUCHAIN(Mandatory) The second RXU chain number when combining two RXU chains to be one RXU ring. GBFD-111202O&M of BTS Interval Type 0~249 0~249 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RCVMD Receive Mode BSC6900 SET GTRXDEV(Optional) RF receiving mode of the TRX MRFD-210301Configuration Management Enumeration Type INDEPENDENT(Independent Receiver), DIVIDING(Dividing Receiver), FOURDIVERSITY(Four Diversity Receiver), MAINDIVERSITY(Main Diversity), NONE(None) INDEPENDENT, DIVIDING, FOURDIVERSITY, MAINDIVERSITY, NONE None None None TRX None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RDC Rate down coefficient [%] BSC6900 ADD IPLOGICPORT(Optional) Speed reduction efficient of the logical port. When detecting link congestion through IPPM, the system reduces the bandwidth rate of the logical port by using the value of the bandwidth multiplied by this parameter. None None Interval Type 0~100 0~100 None 96 96 IP logical port None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
REASSEN Allow Reassign BSC6900 SET GCELLCCBASIC(Optional) Whether to allow the reassignment function GBFD-112501TCH Re-assignment Enumeration Type NO(No), YES(Yes)NO, YES None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
REASSFREQBAND Frequency Band of Reassign BSC6900 SET GCELLCCAD(Optional) Whether to re-assign the radio channels on a different band or on the same band. This can help minimize the decrease in service quality due to interference, faulty TRX paths, or faulty project constructions. GBFD-112501TCH Re-assignment Enumeration Type Same_Band(Same Band), Diff_Band(Different Band) Same_Band, Diff_BandNone None None Cell This parameter is valid when "REASSEN" in the "SET GCELLCCBASIC" command is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved To improve the success rate of reassignment, it is recommended that you use the default value Different Band. That is, the frequency band of the preferentially reassigned channel is different from what is used in the original assignment.
RECEIVEQUALTHRSHAMRFR ReceiveQualThrshAMRFR BSC6900 SET GCELLHOIUO(Optional) IUO cell receive quality threshold (AMRFR), which is used for IUO handover decision GBFD-113201GBFD-115501 Concentric CellAMR FR Interval Type 0~70 0~70 None None 50 Cell This parameter is valid only when "IUOTP" in "ADD GCELL" is set to Concentric_cell. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RECEIVEQUALTHRSHAMRHR ReceiveQualThrshAMRHR BSC6900 SET GCELLHOIUO(Optional) IUO cell receive quality threshold (AMRHR), which is used for IUO handover decision GBFD-113201GBFD-115502 Concentric CellAMR HR Interval Type 0~70 0~70 None None 40 Cell This parameter is valid only when "IUOTP" in "ADD GCELL" is set to Concentric_cell. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RECLEVHYST RX_LEV Hysteresis BSC6900 SET GCELLHOIUO(Optional) One of the parameters that decide the underlay and overlay areas. The underlay and overlay areas are determined by "RX_QUAL Threshold", "RX_LEV Threshold", "RX_LEV Hysteresis", "TA Threshold", and "TA Hysteresis" together. GBFD-113201Concentric Cell Interval Type 0~63 0~63 dB None 5 Cell This parameter is valid only when "IUOTP" in "ADD GCELL" is set to Concentric_cell and "ENIUO" is set to OFF. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RECLEVTHRES RX_LEV Threshold BSC6900 SET GCELLHOIUO(Optional) One of the parameters that decide the underlay and overlay areas. The underlay and overlay areas are determined by "RX_QUAL Threshold", "RX_LEV Threshold", "RX_LEV Hysteresis", "TA Threshold", and "TA Hysteresis" together. GBFD-113201Concentric Cell Interval Type 0~63 0~63 dB None 30 Cell This parameter is valid only when "IUOTP" in "ADD GCELL" is set to Concentric_cell and "ENIUO" is set to OFF. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RECLEVUOHOALLOW RX_LEV for UO HO Allowed BSC6900 SET GCELLHOIUO(Optional) Whether to use the downlink receive level as a condition in IUO handover decision GBFD-113201Concentric Cell Enumeration Type NO(No), YES(Yes)NO, YES None None YES Cell This parameter is valid only when "IUOTP" in "ADD GCELL" is set to Concentric_cell. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RecordDiscardedPagingInfoFlag Record Discarded Paging Msg BSC6900 SET OTHSOFTPARA(Optional) With traffic control enabled, the BSC discards some paging messages. This parameter specifies whether to record detailed information of paging messages discarded by the BSC in the commissioning logs. GBFD-111705GSM Flow Control Enumeration Type NO, YES NO, YES None None NO BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RECOVERTHD Decrease rate alarm recover threshold BSC6900 ADD IPLOGICPORT(Optional) Speed reduction alarm recovery threshold None None Interval Type 20~99 20~99 None 30 30 IP logical port None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RECQUALTH RX_QUAL Threshold BSC6900 SET GCELLHOIUO(Optional) One of the parameters that decide the underlay and overlay areas. If "En Iuo Out Cell Allowed" is set to OFF, the underlay and overlay areas are determined by "RX_QUAL Threshold", "RX_LEV Threshold", "RX_LEV Hysteresis", "TA Threshold", and "TA Hysteresis" together; if "En Iuo Out Cell Enable" is set to ON, the underlay and overlay areas are determined by "RX_QUAL Threshold", "UtoO HO Received Level Threshold", "OtoU HO Received Level Threshold", "TA Threshold", and "TA Hysteresis" together. GBFD-113201Concentric Cell Interval Type 0~70 0~70 None None 60 Cell This parameter is valid only when "IUOTP" in "ADD GCELL" is set to Concentric_cell. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RECQUALUOHOALLOW RX_QUAL for UO HO Allowed BSC6900 SET GCELLHOIUO(Optional) Whether to use the downlink receive quality as a condition in IUO handover decision GBFD-113201Concentric Cell Enumeration Type NO(No), YES(Yes)NO, YES None None NO Cell This parameter is valid only when "IUOTP" in "ADD GCELL" is set to Concentric_cell. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RED Backup BSC6900 ADD BRD(Mandatory) Whether to back up the data of the board MRFD-210301Configuration Management Enumeration Type YES(YES), NO(NO) YES, NO None None None Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ReduceTransBwInt Interval to Reduce Transmission Bandwidth when Congested BSC6900 SET BSCPSSOFTPARA(Optional) Interval for releasing the secondary links in the congestion state. GBFD-111705GSM Flow Control Interval Type 0~50 0~50 ms None 10 BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ReduceTransBwNum Number of Transmission Bandwidth to Reduce when Congested BSC6900 SET BSCPSSOFTPARA(Optional) Secondary link bandwidth that is released each time in the congestion state. GBFD-111705GSM Flow Control Interval Type 0~768 0~768 None None 3 BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
REF2MCLK2SRC Port for LINE2 BSC6900 SET CLK(Optional)Port for output LINE2 MRFD-210502BSC/RNC Clock Interval Type 0~31 0~31 None None None Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
REF2MCLK2SRCBAK Back-up port for LINE2 BSC6900 SET CLK(Optional)Back-up port for output LINE2 MRFD-210502BSC/RNC Clock Interval Type 0~31 0~31 None None None Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
REF2MCLKSRC Port for LINE1 BSC6900 SET CLK(Optional)Port for output LINE1 MRFD-210502BSC/RNC Clock Interval Type 0~31 0~31 None None None Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
REF2MCLKSRCBAK Back-up port for LINE1 BSC6900 SET CLK(Optional)Back-up port for output LINE1 MRFD-210502BSC/RNC Clock Interval Type 0~31 0~31 None None None Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
REF2MCLKSW1 Switch of panel 2M BITS1 BSC6900 SET CLK(Optional)Switch of panel BITS1(2M) MRFD-210502BSC/RNC Clock Enumeration Type OFF(OFF), ON(ON) OFF, ON None None None Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
REF2MCLKSW2 Switch of panel 2M BITS2 BSC6900 SET CLK(Optional)Switch of panel BITS2(2M) MRFD-210502BSC/RNC Clock Enumeration Type OFF(OFF), ON(ON) OFF, ON None None None Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
REFUSELOCALCLK Use SGSN clock source BSC6900 SET CLK(Optional)Whether to use SGSN clock source MRFD-210502BSC/RNC Clock Enumeration Type NO(NO), YES(YES) NO, YES None NO NO Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
REGION Region Information BSC6900 SET BTSLSW(Optional) Region information of the IP BTS configured with local switching GBFD-117702BTS Local Switch Interval Type 0~94 0~94 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
REHOSTABSTIME ReHost Absolute Time BSC6900 SET GREDGRPPRIMHOSTPOLICY(Mandatory) Absolute time of re-homing GBFD-113725BSC Node Redundancy Compound Type hour, min, sec 00:00:00~23:59:59 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
REHOSTDELAYTIME ReHostDelayTime BSC6900 SET GREDGRPPRIMHOSTPOLICY(Mandatory) Delay time of re-homing GBFD-113725BSC Node Redundancy Interval Type 1~3600 1~3600 s 600 None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
REHOSTTYPE ReHost Type BSC6900 SET GREDGRPPRIMHOSTPOLICY(Mandatory) Policy type of re-homing GBFD-113725BSC Node Redundancy Enumeration Type REHOSTRIGHTNOW(ReHostRightNow), REHOSTDELAY(ReHostDelay), REHOSTWHEN(ReHostWhen) REHOSTRIGHTNOW, REHOSTDELAY, REHOSTWHEN None REHOSTDELAY REHOSTDELAY Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
REINITTBL Reinitialize Neighbour Cell Table BSC6900 ADD AISSCFG(Mandatory) Whether to re-initialize the neighboring cell pair for software synchronization. GBFD-118201Soft-Synchronized Network Enumeration Type NO(NO), YES(YES) NO, YES None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None.
RELATEDCN Associated Board CN BSC6900 SET BTSRXUBP(Mandatory) Cabinet number of the associated module. The associated two MRFUs or GRFUs must be in the same cell. GBFD-111202O&M of BTS Interval Type 0~62 0~62 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RELATEDFCUENABLED Extend Connection Configuration Enabled BSC6900 SET BTSDFCUBP(Optional) Whether to enable the configuration of the "Extend Connection" attribute. The "Extend Connection" attribute describes the cascading relationship of the DFCB, which helps the DFCU perform the six-in-one function. GBFD-111202O&M of BTS Enumeration Type NO(NO), YES(YES) NO, YES None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RELATEDMODFUNC Associated Board Function BSC6900 SET BTSRXUBP(Optional) Function to be performed by two associated modules GBFD-111202O&M of BTS Enumeration Type OFF(OFF), POWERSHARING(Power Sharing Between Boards), RF_FH(RF Frequency Hopping Between Boards) OFF, POWERSHARING, RF_FH None None OFF BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RELATEDSN Associated Board SN BSC6900 SET BTSRXUBP(Mandatory) Slot number of the associated module GBFD-111202O&M of BTS Interval Type 0~23 0~23 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RELATEDSRN Associated Board SRN BSC6900 SET BTSRXUBP(Mandatory) Subrack number of the associated module GBFD-111202O&M of BTS Interval Type 0~255 0~255 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RELATEDTRACK Cascading Tributary BSC6900 SET BTSDFCUBP(Optional) Tributary Number of the DFCB that is cascaded to the DFCU. The "Extend Connection" attribute describes the cascading relationship of the DFCB, which helps the DFCU perform the six-in-one function. GBFD-111202O&M of BTS Enumeration Type A(A), B(B), NONE(NONE) A, B, NONE None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
REMARK Remark BSC6900 ADD TRMMAP(Optional)ADD TRMFACTOR(Mandatory) Remark None None String Type None 1~31 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
REMARK Route use description BSC6900 ADD IPRT(Mandatory) Purpose description of the route record None None String Type None 1~250 characters None None None IP route None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
REMOTENSVLI Remote NSVL ID BSC6900 ADD NSVLREMOTE(Mandatory) Remote NSVL ID of the Gb IP route. GBFD-118603Gb over IP Interval Type 0~1023 0~1023 None None None NSE None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
REP Repeat BSC6900 ADD GSMSCB(Mandatory) A key parameter that indicates how many times the BSC broadcasts cell messages. You can obtain the cell broadcast times by running the "DSP GSMSCB" command.The value 0 indicates no repeat. GBFD-113602Simplified Cell Broadcast Interval Type 0~65535 0~65535 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
REPEATDLFASET Repeated Downlink FACCH BSC6900 SET GCELLCCBASIC(Optional) Whether to enable the Repeated Downlink FACCH function for the cell GBFD-113721Robust Air Interface Signalling Enumeration Type NO(No), YES(Yes)NO, YES None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
REPEATDLFATHRED Repeated Downlink FACCH Threshold BSC6900 SET GCELLCCBASIC(Optional) If the cell supports the Repeated Downlink FACCH function and the measured downlink quality is lower than the downlink quality threshold, the BTS enables the repeated transmission of FACCH frames. GBFD-113721Robust Air Interface Signalling Interval Type 0~7 0~7 None None None Cell This parameter is valid when "REPEATDLFASET" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
REPEATSASET Repeated SACCH BSC6900 SET GCELLCCBASIC(Optional) Whether to enable the Repeated SACCH function for the cell GBFD-113721Robust Air Interface Signalling Enumeration Type NO(No), YES(Yes)NO, YES None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
REPORT Report Progress Flag BSC6900 LOD BTSSW(Optional)LOD BTSPATCH(Optional)CON BTSPATCH(Optional) Whether to report the progress GBFD-111202O&M of BTS Enumeration Type REPORT(Report), NOTREPORT(Not Report) REPORT, NOTREPORT None REPORT None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RESALMID Reserved Alarm ID BSC6900 SET BTSENVALMPORT(Optional) Whether to reserve the binding of the alarm ID and the alarm port MRFD-210304Faulty Management Enumeration Type NO(No), YES(Yes)NO, YES None YES YES BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RESAUDITCTHD Resource Audit control threshold BSC6900 SET FCCPUTHD(Optional) CPU usage threshold for resource auditing control. When the average CPU usage of sliding windows reaches or exceeds the threshold, resource auditing control is triggered. This parameter is valid only when "Board Class" is "XPU". WRFD-040100Flow Control Interval Type 30~100 30~100 per cent None 60 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RESAUDITCTHD Resource Audit control threshold BSC6900 SET FCMSGQTHD(Optional) Packet queue usage threshold for resource auditing control. When the average packet queue usage of sliding windows reaches or exceeds the threshold, resource auditing control is triggered. This parameter is valid only when "Board Class" is "XPU". WRFD-040100Flow Control Interval Type 30~100 30~100 per cent None 75 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RESAUDITRTHD Resource Audit restore threshold BSC6900 SET FCCPUTHD(Optional) CPU usage threshold for recovery from resource auditing control. When the average CPU usage of sliding windows is lower than the threshold, resource auditing control is stopped. This parameter is valid only when "Board Class" is "XPU". WRFD-040100Flow Control Interval Type 30~100 30~100 per cent None 50 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RESAUDITRTHD Resource Audit restore threshold BSC6900 SET FCMSGQTHD(Optional) Packet queue usage threshold for recovery from resource auditing control. When the average packet queue usage of sliding windows is lower than the threshold, resource auditing control is stopped. This parameter is valid only when "Board Class" is "XPU". WRFD-040100Flow Control Interval Type 30~100 30~100 per cent None 65 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RESAUDITSW Resource audit flow control switch BSC6900 SET FCSW(Optional) Whether to control the resource auditing flow WRFD-040100Flow Control Enumeration Type ON, OFF ON, OFF None None ON Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
5/5/2014
Confidential Information of Huawei.
No Spreading without Permission
Page16of42
226347869.xls.ms_office Security Level:
ResCheckAllowed ResCheckAllowed BSC6900 SET OTHSOFTPARA(Optional) Whether to perform resource checks on the resource usage system and resource management system. Resource checks can prevent resource hanging in case of anomalies. Resource checks cover channel resources, transmit resources, and BSC resources. GBFD-111203O&M of BSC Enumeration Type NO, YES NO, YES None None YES BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RESELHYST Cell Reselection Hysteresis BSC6900 SET GCELLNC2PARA(Optional) During cell reselection, the level of the target cell must be greater than "cell reselection level threshold " + "cell reselection hysteresis". Hysteresis must be adjusted according to the reselection performance statistic result and the actual network status. The flexible setting of this parameter can provide effective guidance for reselection between two neighboring cells. GBFD-116201Network-Controlled Cell Reselection (NC2) Interval Type 0~63 0~63 None None 6 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RESELINTERVAL Cell Reselect Interval BSC6900 SET GCELLNC2PARA(Optional) NC2 cell reselection interval in the same cell. GBFD-116201Network-Controlled Cell Reselection (NC2) Interval Type 1~10 1~10 s None 2 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RESELWATCHPERIOD Normal Cell Reselection Watch Period BSC6900 SET GCELLNC2PARA(Optional) Number of receiving level of the servicing cell before judgment is performed according to P/N regulation. GBFD-116201Network-Controlled Cell Reselection (NC2) Interval Type 1~32 1~32 None None 10 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RESELWORSENLEVTHRSH Normal Cell Reselection Worsen Level Threshold BSC6900 SET GCELLNC2PARA(Optional) The times of servicing cell receiving level lower than the cell reselection level threshold in the normal reselection period. GBFD-116201Network-Controlled Cell Reselection (NC2) Interval Type 1~32 1~32 None None 1 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ReservedDynPdchPreTranNum Number of Reserved Dynamic Channel BSC6900 SET GCELLPSCHM(Optional) This parameter specifies the default pre-converted PDCHs in the dynamic transferable channel pool. GBFD-113101PDCH Dynamic Adjustment Interval Type 0~8 0~8 None None 0 Cell None Read & Write Y Cell Less than 5 minutes None
ReservedIdleCh Reserved TCH Number for PA Turning On BSC6900 SET GCELLOTHEXT(Optional) Number of idle channels reserved in a cell. When the number of idle channels in a cell is smaller than the threshold, the BSC enables the power amplifier on a TRX. GBFD-111602TRX Power Amplifier Intelligent Shutdown Interval Type 0~16 0~16 None None None Cell This parameter is valid when "DYNOpenTrxPower" in the "SET GCELLBASICPARA" command is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ResetAlmDelaySwitch BTS Reset Alarm Delay Switch BSC6900 SET OTHSOFTPARA(Optional) Whether to withhold link breakdown alarms in case of BTS resets due to data configurations GBFD-111202O&M of BTS Enumeration Type NO, YES NO, YES None None NO BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ResetAlmDelayTime BTS Reset Alarm Delay Time BSC6900 SET OTHSOFTPARA(Optional) If OML links break down after BTS resets caused by data configurations and recover within the period specified by this parameter, configuration reset alarms are reported; If OML links fail to recover within the period specified by this parameter, OML link breakdown alarms are reported. GBFD-111202O&M of BTS Interval Type 0~65535 0~65535 min None 5 BSC6900This parameter is valid only when "ResetAlmDelaySwitch" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RESETINTERVAL Reset Interval of Account Lock Counter BSC6900 SET PWDPOLICY(Optional) Interval for resetting the counter when the user fails to log in MRFD-210305Security Management Interval Type 1~60 1~60 min None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RESETRETRY Reset Retry BSC6900 SET BSCNSPARA(Optional) Retry times after the peer response timer expires during NSVC reset. GBFD-114101GPRS Interval Type 1~255 1~255 None None 3 BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RESETTIMER Reset Timer BSC6900 SET BSCNSPARA(Optional) Duration of the peer response timer during NSVC reset. GBFD-114101GPRS Interval Type 1~120 1~120 s None 10 BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RESID Reason BSC6900 TST SNDRSI(Mandatory) Reason for activating the radio status procedure. GBFD-119001Gb Interface Function Enumeration Type MSLOST(RADIO_STS_MS_LOST), QUALITYBAD(RADIO_STS_QUALITY_BAD), CELLRESELECT(RADIO_STS_CELL_RESELECT) MSLOST, QUALITYBAD, CELLRESELECT None None None BSC None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
RespReqSel Response on out-BSC HO Req BSC6900 SET OTHSOFTPARA(Optional) Whether the HO RQD messages sent by the BSC to an MSC carry response request cells. Response request cells are optional. They are used to inform the MSC whether it needs to return HO REJECT messages when HO RQD messages fail to trigger handovers. GBFD-111804A Interface Protocol Process Enumeration Type NO, YES NO, YES None None YES BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The setting of this parameter requires negotiation with the MSC, so that the MSC can correctly process HO RQD messages.
REST Rest Flag BSC6900 DLD LICENSE(Optional)ULD LICENSE(Optional) Whether to resume broken download GBFD-111203MRFD-210403 O&M of BSCLicense Management Enumeration Type NO(Not Rest), YES(Need Rest) NO, YES None NO None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RESTARTTMR Sub-protocol negotiate out time[S] BSC6900 ADD PPPLNK(Optional) Duration of the PPP/MP link restart timer GBFD-118611GBFD-118622 Abis IP over E1/T1A IP over E1/T1 Interval Type 2~5 2~5 s 3 3 PPP link None Read & Write Y BSC6900 Interrupt the service until negotiate successfully again. Negotiation can succeed only when the configuration is consistent on the local and peer ends.
RESTARTTMR Sub-protocol negotiate out time[S] BSC6900 ADD MPLNK(Optional) Duration of the PPP/MP link restart timer GBFD-118611GBFD-118622 Abis IP over E1/T1A IP over E1/T1 Interval Type 2~5 2~5 s 3 3 MP link None Read & Write N (No impact on the UE in idle mode) Not involved Not involved Negotiation can succeed only when the configuration is consistent on the local and peer ends.
restype Alarm Restore Type BSC6900 EXP ALMLOG(Optional)STAALMLOG(Optional) Restoration type of the alarm MRFD-210304Faulty Management Bit Field Type Noneed, Manually, Reset, Normally, Correlative, Configuration, Expired Noneed, Manually, Reset, Normally, Correlative, Configuration, Expired None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RESUMETIMER Resume Timer BSC6900 ADD GNRNC(Optional) Time for the BSC to initiate the common measurement or information exchange procedure after this procedure fails MRFD-211402MBSC Load Balancing Interval Type 0~86400 {0~86400} s 30 30 BSC Set when Allow Common Measurement at Iur-g is set to Yes or Allow Info Exchange at Iur-g is set to Yes Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
REVCHANNUM Reserved Channel Number BSC6900 SET GCELLCHMGBASIC(Optional) When assign channels, the BSC ensures that the sum of the number of channels occupied by high-priority users and the number of idle channels reserved for high-priority users is no smaller than this parameter. Every time the BSC assigns channels to a user whose priority is lower than "Highest Priority", it checks whether the sum of the number of channels occupied by users of "Highest Priority" and the number of idle channels is larger than the number of the reserved channels. If yes, the BSC normally assigns channels for the user; if not, the BSC does not assign a TCHF. GBFD-116001Resource Reservation Interval Type 0~190 0~190 None None 0 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The range of this parameter is determined by the cell configuration. The lower limit is 0, and the upper limit is sum of TCHF, TCHH and Dynamic PDCH configured in the cell.
RFMAXPWRDEC Max RC Power Reduction BSC6900 SET GCELLOTHEXT(Optional) Maximum number of levels that the BTS RF power decreases. This parameter is used to control the decrease in the BTS RF power. If the value is too large, the BTS power decreases too much. If the value is too small, the BTS power decreases less and the power decrease effect is not good. MRFD-210301Configuration Management Interval Type 0~21 0~21 None None 5 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved If this parameter is set to a greater value, the BTS power decreases too much. If this parameter is set to a smaller value, the BTS power decreases insignificantly and thus the power decrease effect is unsatisfactory.
RFRESINDPRD Radio Resource Report Period BSC6900 SET GCELLCCCH(Optional) Interval for sending the radio resource indication messages. The TRX reports the interference level for each of the channels that have been idle for the whole measurement period.This parameter is used by a BTS to inform the BSC of the interference levels on idle channels of a TRX. For details, see GSM Rec. 08.58 and 08.08. GBFD-111004Radio Dedicated Channel Management Interval Type 0~255 0~255 s None 10 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RFT Execute Interval BSC6900 ADD SUBTSK(Optional) Interval for executing the scheduled subtask The unit is determined according to the time mode. 1. If the time mode is set to "DAILY_T" or "DAILY_C", the unit is day. 2. If the time mode is set to "WEEKLY_T" or "WEEKLY_C", the unit is week. 3. If the time mode is set to "MONTHLY_T" or "MONTHLY_C", the unit is month. GBFD-111203O&M of BSC Interval Type 1~100 1~100 None 1 None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RFUCFGBYSLOT Configure RFU by Slot BSC6900 ADD BTS(Optional) Whether to enable the BTS to support configuring RFU by slot. GBFD-110000GBSS9.0 System Improvement Enumeration Type NO(No), YES(Yes)NO, YES None NO None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RGPSINDICATION GPS or RGPS BSC6900 SET BTSDGPSBP(Optional) Satellite card protocol that is enabled to communicate with the satellite card connecting to the DGPS. If "RGPS" is specified, it indicates that the RGPS satellite card protocol is enabled to communicate with the satellite card connecting to the DGPS. If "GPS" is specified, it indicates that the GPS satellite card protocol is enabled to communicate with the satellite card connecting to the DGPS. GBFD-510401BTS GPS Synchronization Enumeration Type RGPS(RGPS), GPS(GPS) RGPS, GPS None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RIMSUP RIM Support BSC6900 ADD NSE(Optional) Whether to support ran information management (RIM). IN the RIM procedure, RANs(Radio Access Network) can exchange messages through the core network. GBFD-116301Network Assisted Cell Change (NACC) Enumeration Type NO(No Support), YES(Support) NO, YES None NO NO NSE None Read & Write Y NSE Less than 5 minutes The SIGBVC must be reset after this switch is turned on. The BSC supports the RIM when the SGSN supports the RIM.
RLCN Channel No. BSC6900 SET E1T1LOP(Optional) The loopback channel number when the port loopback mode is set to TDM remote loopback None None Bit Field Type TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10, TS11, TS12, TS13, TS14, TS15, TS16, TS17, TS18, TS19, TS20, TS21, TS22, TS23, TS24, TS25, TS26, TS27, TS28, TS29, TS30, TS31 TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10, TS11, TS12, TS13, TS14, TS15, TS16, TS17, TS18, TS19, TS20, TS21, TS22, TS23, TS24, TS25, TS26, TS27, TS28, TS29, TS30, TS31 None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RLT Radio Link Timeout BSC6900 SET GCELLCCBASIC(Optional) Time for disconnecting a call when the MS fails to decode the SACCH. Once a dedicated channel is assigned to the MS, the counter S is enabled and the initial value is set to this parameter value.Each time an SACCH message is not decoded, the counter S decreases by 1. Each time an SACCH message is correctly decoded, the counter S increases by 2. When the counter S is equal to 0, the downlink radio link is considered as failed. Therefore, when the voice or data quality is degraded to an unacceptable situation and it cannot be improved through power control or channel handover, the connection is to be re-established or released. GBFD-111004Radio Dedicated Channel Management Enumeration Type 4_Times, 8_Times, 12_Times, 16_Times, 20_Times, 24_Times, 28_Times, 32_Times, 36_Times, 40_Times, 44_Times, 48_Times, 52_Times, 56_Times, 60_Times, 64_Times 4_Times, 8_Times, 12_Times, 16_Times, 20_Times, 24_Times, 28_Times, 32_Times, 36_Times, 40_Times, 44_Times, 48_Times, 52_Times, 56_Times, 60_Times, 64_Times, step: 480 ms ms None 52_Times Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RMTTCATERTRANSMODE Remote TC subrack Ater transmission mode BSC6900 SET BSCBASIC(Optional) Transmission mode on the Ater interface of the remote TC subrack GBFD-116902Ater Compression Transmission Enumeration Type STANDALONETC(Stand Alone TC ), MASTERINPOOLTC(Master in Pool TC), SLAVEINPOOLTC(Slave in Pool TC) STANDALONETC, MASTERINPOOLTC, SLAVEINPOOLTC None None None BSC6900RMTTCATERTRANSMODE must be set when "ISTCCENTRAL" in the "ADD SUBRACK" command is set to YES. Read & Write Y BSC6900 Less than 5 minutes None
RNCID RNC ID BSC6900 ADD GEXT3GCELL(Optional) RNC ID of a 3G external cell. MRFD-210301Configuration Management Interval Type 0~4095 0~4095 None None 0 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RNCINDEX Neighboring RNC Index BSC6900 ADD GEXT3GCELL(Optional) Internal index of a neighboring RNC. This parameter is set to 255 when the neighboring RNC that serves the 3G external neighboring is not configured. You can use the "LST GNRNC" command to check whether the neighboring RNC is configured. MRFD-211402MBSC Load Balancing Interval Type 0~6,255 {{0~6}, {255}} None 255 None BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RNCINDEX Neighboring RNC Index BSC6900 ADD GNRNC(Mandatory)ADD GIURGCONN(Mandatory) Internal index of a neighboring RNC MRFD-211402MBSC Load Balancing Interval Type 0~6 {0~6} None None None BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RNCNAME Neighboring RNC Name BSC6900 ADD GNRNC(Mandatory) Name of a neighboring RNC. The name is used to uniquely identify a neighboring RNC. MRFD-211402MBSC Load Balancing String Type None 1~64 characters None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RootCert Root Certificate File Name BSC6900 SET CERTFILE(Optional) Name of the root certificate file MRFD-210305Security Management String Type None 0~200 characters None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ROUTENO Route No. BSC6900 ADD SGSNROUTEINFO(Mandatory) Identifies a router uniquely. GBFD-118603Gb over IP Interval Type 1~100 1~100 None None None BSC None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
ROUTEPORTNO Route Port No. BSC6900 ADD SGSNROUTEINFO(Mandatory) Router port number. GBFD-118603Gb over IP Interval Type 1~100 1~100 None None None BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RPTDLVQIALLOWED Report Downlink VQI Allowed BSC6900 SET GCELLSOFT(Optional) Whether to allow the BTS to report the downlink voice quality index (VQI) GBFD-116801Voice Quality Index (Uplink VQI) Enumeration Type DISABLE(Disable), ENABLE(Enable), UNSUPPORT(Unsupport) DISABLE, ENABLE, UNSUPPORT None None DISABLE Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RPTPERIODI Cell Reselection MR Period in Packet Idle Mode BSC6900 SET GCELLNWCTRLMSRPARA(Optional) Cell reselection measurement report period in packet idle mode. GBFD-119107Networking Control Mode Enumeration Type 0.48sec(0.48sec), 0.96sec(0.96sec), 1.92sec(1.92sec), 3.84sec(3.84sec), 7.68sec(7.68sec), 15.36sec(15.36sec), 30.72sec(30.72sec), 61.44sec(61.44sec) 0.48sec, 0.96sec, 1.92sec, 3.84sec, 7.68sec, 15.36sec, 30.72sec, 61.44sec s None 15.36sec Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RPTPERIODT Cell Reselection MR Period in Packet Transfer Mode BSC6900 SET GCELLNWCTRLMSRPARA(Optional) Cell reselection measurement report period in packet transmission mode. GBFD-119107Networking Control Mode Enumeration Type 0.48sec(0.48sec), 0.96sec(0.96sec), 1.92sec(1.92sec), 3.84sec(3.84sec), 7.68sec(7.68sec), 15.36sec(15.36sec), 30.72sec(30.72sec), 61.44sec(61.44sec) 0.48sec, 0.96sec, 1.92sec, 3.84sec, 7.68sec, 15.36sec, 30.72sec, 61.44sec s None 0.96sec Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RPTTHD Decrease rate alarm report threshold BSC6900 ADD IPLOGICPORT(Optional) Speed reduction alarm report threshold None None Interval Type 20~99 20~99 None 20 20 IP logical port None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RPTVOICE Report Speech Quality BSC6900 SET GCELLOTHBASIC(Optional) Whether to allow the BTS to report the voice quality index (VQI). If this parameter is set to Report, the BTS reports the VQI. The BSC collects the traffic statistics on a per VQI basis. There are 11 levels of speech quality. If the level is lower, the speech quality is better. The traffic related to AMR and non-AMR is measured separately, and thus the speech quality is monitored. GBFD-116801Voice Quality Index (Uplink VQI) Enumeration Type NO(Not report), YES(Report), NONE(None) NO, YES, NONE None None NO Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RQSIGNLEN Filter length for sdcch rep_quant BSC6900 SET GCELLHOFITPEN(Optional) For the purpose of accurately reflecting the radio environment of a network, filtering is performed on the measured values in several consecutive measurement reports. This parameter indicates the number of enhanced measurement reports received on signaling channels used to filter the REP_QUANT value. GBFD-117501Enhanced Measurement Report(EMR) Interval Type 0~31 0~31, step:480 for TCH and 470 for SDCCH ms None 2 Cell This parameter is valid only when "MEASURETYPE" in "SET GCELLCCUTRANSYS" is set to EnhMeasReport. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RQTRAFFLEN Filter length for tch rep_quant BSC6900 SET GCELLHOFITPEN(Optional) For the purpose of accurately reflecting the radio environment of a network, filtering is performed on the measured values in several consecutive measurement reports. This parameter indicates the number of enhanced measurement reports received on voice channels used to filter the REP_QUANT value. GBFD-117501Enhanced Measurement Report(EMR) Interval Type 0~31 0~31, step:480 for TCH and 470 for SDCCH ms None 6 Cell This parameter is valid only when "MEASURETYPE" in "SET GCELLCCUTRANSYS" is set to EnhMeasReport. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RSCGRPN Rscgrp No. BSC6900 ADD IPPATH(Mandatory) Resource group number of the PATH None None Interval Type 0~2047 0~2047 None None None AAL2 path When the value of "ADDTORSCGRP" in "ADD AAL2PATH" is set to YES, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved The resource group must exist.
RSCMNGMODE Resource Management Mode BSC6900 ADD RSCGRP(Mandatory) The parameter indicates whether the resource group is shared or is used by a specific telecom carrier. None None Enumeration Type SHARE(SHARE), EXCLUSIVE(EXCLUSIVE) SHARE, EXCLUSIVE None None None Transmission resource group When "ISFIRSTCLASSE" in "ADD RSCGRP" is set to YES, this parameter is valid. Read & Write Not involved Not involved Not involved The parameter cannot be modified.
RSCMNGMODE Resource management mode BSC6900 ADD IPLOGICPORT(Optional) Resource management mode. The logical port working in the SHARE mode can be shared by multiple carriers. The logical port working in the EXCLUSIVE mode can be used by only one carrier. None None Enumeration Type SHARE, EXCLUSIVE SHARE, EXCLUSIVE None None None IP logical port None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
RSCPENALTYTIMER RscPenaltyTimer BSC6900 SET GCELLHOFITPEN(Optional) Timer for punishing the neighboring cells when handover failures occur due to resource-related causes, such as resources being insufficient GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 0~255 0~255 s None 5 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RSCPOFF RSCP Offset BSC6900 ADD G3GNCELL(Optional) This parameter adjusts "Min RSCP threshold" to enable the selection of 3G candidate cells based on cell priorities GBFD-114301GBFD-114302 GSM/WCDMA InteroperabilityGSM/TD-SCDMA Interoperability Interval Type 0~63 0~63 dB None 3 Cell A 3G cell can be added into the candidate cell queue when the following conditions are met: "INTERRATOUTBSCHOEN" is set to YES; "BET3GHOEN" is set to YES; the RSCP of the 3G cell for a period of time is greater than the sun of "HORSCPTH3G" and "RSCPOFF". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RSCPTHRES RSCP threshold for layer of 3G cell BSC6900 ADD GEXT3GCELL(Optional) This parameter determines the layers of 3G neighboring cells. If the measured value of a 3G neighboring cell is lower than this threshold, the 3G neighboring cell is positioned at the bottom layer, that is, layer 4. GBFD-114301GBFD-114302 GSM/WCDMA InteroperabilityGSM/TD-SCDMA Interoperability Interval Type 0~63 0~63 dB None 30 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RSDSRC RSD alarm source BSC6900 SET OPT(Optional) RSD alarm triggering source None None Enumeration Type BASIS_OF_B1, BASIS_OF_B2 BASIS_OF_B1, BASIS_OF_B2 None None None Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RSFSRC RSF alarm source BSC6900 SET OPT(Optional) RSF alarm triggering source None None Enumeration Type BASIS_OF_B1, BASIS_OF_B2 BASIS_OF_B1, BASIS_OF_B2 None None None Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RSLCTOFFER GPRS Reselection Offset BSC6900 SET GCELLNCRESELECTPARA(Optional) Used for calculating C2. The MS with a large value can be assigned with high access priority. GBFD-114101GPRS Enumeration Type MINUS_52db(-52db), MINUS_48db(-48db), MINUS_44db(-44db), MINUS_40db(-40db), MINUS_36db(-36db), MINUS_32db(-32db), MINUS_28db(-28db), MINUS_24db(-24db), MINUS_20db(-20db), MINUS_16db(-16db), MINUS_12db(-12db), MINUS_10db(-10db), MINUS_8db(-8db), MINUS_6db(-6db), MINUS_4db(-4db), MINUS_2db(-2db), Zerodb(0db), 2db(2db), 4db(4db), 6db(6db), 8db(8db), 10db(10db), 12db(12db), 16db(16db), 20db(20db), 24db(24db), 28db(28db), 32db(32db), 36db(36db), 40db(40db), 44db(44db), 48db(48db), nouse(no use) MINUS_52db, MINUS_48db, MINUS_44db, MINUS_40db, MINUS_36db, MINUS_32db, MINUS_28db, MINUS_24db, MINUS_20db, MINUS_16db, MINUS_12db, MINUS_10db, MINUS_8db, MINUS_6db, MINUS_4db, MINUS_2db, Zerodb, 2db, 4db, 6db, 8db, 10db, 12db, 16db, 20db, 24db, 28db, 32db, 36db, 40db, 44db, 48db, no use dB None MINUS_2db Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RSLDL RSLDL BSC6900 SET BTSBWPARA(Mandatory) Average down-bandwidth of RSL link in BTS. GBFD-111202O&M of BTS Interval Type 0~64 0~64 kbit/s None None Transport channel None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RSLDSCP RSL DSCP BSC6900 SET BTSABISPRIMAP(Optional) Differentiated service code of the specified RSL None None Interval Type 0~63 0~63 None None None BSC6900None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
RSLPRI RSL Priority BSC6900 SET BTSABISPRIMAP(Optional) RSL service priority None None Interval Type 0~7 0~7 None None None BSC6900None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
RSLUL RSLUL BSC6900 SET BTSBWPARA(Mandatory) Average up-bandwidth of RSL link in BTS. GBFD-111202O&M of BTS Interval Type 0~64 0~64 kbit/s None None Transport channel None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RSLVLANID RSL VlanId BSC6900 SET BTSABISPRIMAP(Optional) Specified RSL Vlan Id None None Interval Type 2~4094 2~4094 None None None BSC6900None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
RSLWS RSL LAPD Window size BSC6900 SET BTSLAPDWS(Optional) Size of the RSL LAPD window GBFD-118601Abis over IP Interval Type 0~96 0~96 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RSNDES Lock Reason BSC6900 LCK CMCTRL(Mandatory) reason for locking the configuration and management control rights. None None Enumeration Type COMMISSIONING(Commissioning), UPGRADE(Upgrade), RESTORE(Restore) COMMISSIONING, UPGRADE, RESTORE None None None BSC6900None Read & Write Not involved Not involved Not involved None
RSSThres Relative Signal Strength Threshold BSC6900 SET OTHSOFTPARA(Optional) Threshold of the level difference between a neighboring cell and the serving cell, based on which the BSC filters the measured values in the measurement reports and collects traffic statistics during automatic neighboring cell optimization and automatic frequency optimization. The filtering results and collected traffic statistics are later submitted to NaStar for analysis. When a measurement report shows that the signal strength difference between a neighboring cell and the serving cell is larger than ("Relative Signal Strength Threshold" - 64), related traffic statistics will be collected. GBFD-5109012G/3G Neighboring Cell Automatic Optimization Interval Type 0~127 0~127 dB None Set this parameter to about 68 in densely populated urban areas and about 72 in suburban areas. BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RSTF Result File Name BSC6900 RUN BATCHFILE(Optional) Name of the result file generated after the command is executed. If this parameter is not specified, the name of the result file is automatically generated in the format of BATCH_RST_YYYYMMDDHHNNSSmmm. The result file is located in the ftp directory in the main area of the OMU, and you should not add the path when entering the name. The flag of the main area can be queried through the "LST OMUAREA" command. The characters (@, #, !, %, ^, &, *, [, ], /, \, ', and ") cannot appear in the file name. GBFD-111203O&M of BSC String Type None 1~50 characters None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RSTFUN Restart switch BSC6900 ADD OPC(Optional) Whether to enable the restart function. None None Enumeration Type OFF(OFF), ON(ON) OFF, ON None OFF OFF SCCP When the value of "SPCBITS" is set to BIT14 or BIT24, this parameter is valid. Read & Write Y BSC6900 The services are interrupted until the signaling point is available. The switch is off in the case of a signaling point to the single link. After the link to a signaling point is disconnected, the restart procedure is performed. See the ITU-T Q704.
RSTIME Restart Timer BSC6900 ADD BTSPPPLNK(Optional)ADD BTSMPLNK(Optional) Timer GBFD-118611Abis IP over E1/T1 Interval Type 1~65535 1~65535 ms 3000 3000 PPP link None Read & Write Y BTS Less than 5 minutes None
RSVCHMFORECNUM Max Channel Num Reserved for EC BSC6900 SET GCELLCHMGBASIC(Optional) Maximum number of TCH channels reserved for emergency call users GBFD-110202Emergency Call Service (TS12) Interval Type 0~190 0~190 None None 0 Cell This parameter is valid only when "EMCPRILV" in "SET GCELLCCAD" is not set to 15. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RSVDPARA1 Reserved Parameter 1 BSC6900 SET TRANSPATCHPARA(Optional) Parameter 1 reserved for future use. None None Enumeration Type OFF(OFF), ON(ON) OFF, ON None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved Change this parameter will impact the function interrelated with Parameter 1.
RSVDPARA10 Reserved Parameter 10 BSC6900 SET TRANSPATCHPARA(Optional) Parameter 10 reserved for future use. None None Interval Type 0~4294967295 0~4294967295 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved Change this parameter will impact the function interrelated with Parameter 10.
RSVDPARA2 Reserved Parameter 2 BSC6900 SET TRANSPATCHPARA(Optional) Parameter 2 reserved for future use. None None Enumeration Type OFF(OFF), ON(ON) OFF, ON None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved Change this parameter will impact the function interrelated with Parameter 2.
RSVDPARA3 Reserved Parameter 3 BSC6900 SET TRANSPATCHPARA(Optional) Parameter 3 reserved for future use. None None Enumeration Type OFF(OFF), ON(ON) OFF, ON None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved Change this parameter will impact the function interrelated with Parameter 3.
RSVDPARA4 Reserved Parameter 4 BSC6900 SET TRANSPATCHPARA(Optional) Parameter 4 reserved for future use. None None Enumeration Type OFF(OFF), ON(ON) OFF, ON None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved Change this parameter will impact the function interrelated with Parameter 4.
RSVDPARA5 Reserved Parameter 5 BSC6900 SET TRANSPATCHPARA(Optional) Parameter 5 reserved for future use. None None Enumeration Type OFF(OFF), ON(ON) OFF, ON None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved Change this parameter will impact the function interrelated with Parameter 5.
RSVDPARA6 Reserved Parameter 6 BSC6900 SET TRANSPATCHPARA(Optional) Parameter 6 reserved for future use. None None Enumeration Type OFF(OFF), ON(ON) OFF, ON None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved Change this parameter will impact the function interrelated with Parameter 6.
RSVDPARA7 Reserved Parameter 7 BSC6900 SET TRANSPATCHPARA(Optional) Parameter 7 reserved for future use. None None Interval Type 0~4294967295 0~4294967295 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved Change this parameter will impact the function interrelated with Parameter 7.
RSVDPARA8 Reserved Parameter 8 BSC6900 SET TRANSPATCHPARA(Optional) Parameter 8 reserved for future use. None None Interval Type 0~4294967295 0~4294967295 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved Change this parameter will impact the function interrelated with Parameter 8.
RSVDPARA9 Reserved Parameter 9 BSC6900 SET TRANSPATCHPARA(Optional) Parameter 9 reserved for future use. None None Interval Type 0~4294967295 0~4294967295 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved Change this parameter will impact the function interrelated with Parameter 9.
RsvIdleChanNum Reserve Idle Channel Number BSC6900 SET BSCDSTPA(Optional) Number of reserved idle channels. If this parameter is set too small, the power amplifier of carriers may be frequently enabled/disabled; if this parameter is set too large, idle carriers will not be timely closed. GBFD-111602TRX Power Amplifier Intelligent Shutdown Interval Type 0~3 0~3 None None 2 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RT Revertive type BSC6900 SET MSP(Optional) Recovery mode of the MSP protection group GBFD-111701Board Switchover Enumeration Type NON-REVERTIVE(NON-REVERTIVE), REVERTIVE(REVERTIVE) NON-REVERTIVE, REVERTIVE None None None MSP protect group None Read & Write Y BSC6900 If the mode is not consistent, will interrupt service until it is consistent. The setting of this parameter must be negotiated with that on the interconnected side.
RTCONTEXT Routing Context BSC6900 ADD M3LE(Optional)ADD M3DE(Optional) Routing context. None None Interval Type 0~4294967295 0~4294967295 None 4294967295 4294967295 BSC6900None Read & Write Y BSC6900 The services are interrupted until the M3DE is available. The routing context must be unique and needs to be negotiated with the peer.
RTDEST Destination Network Address BSC6900 ADD OMUIPRT(Mandatory) destination IP address. None None IP Address Type None 0.0.0.0~255.255.255.255 None None None BSC6900None Read & Write Not involved Not involved Not involved None
RTDESTMASK Destination Address Mask BSC6900 ADD OMUIPRT(Mandatory) routing mask. None None IP Address Type None 0.0.0.0~255.255.255.255 None None None BSC6900None Read & Write Not involved Not involved Not involved None
RTIDX Route Index BSC6900 ADD BTSIPRT(Optional) Index of the route. The index is unique in a BTS. GBFD-118601Abis over IP Interval Type 0~31 0~31 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RTOALPHA RTO alpha value BSC6900 ADD SCTPLNK(Optional) It is used to calculate the round-trip time of the protocol stack and the RTO value. The value must be smaller than "RTOBETA". In the case of the fixed value of the "RTOBETA", the larger the value is, the less the link delay sensitivity is. None None Interval Type 0~100 0~100 per cent 12 12 SCTP linkNone Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RTOBETA RTO beta value BSC6900 ADD SCTPLNK(Optional) It is used to calculate the round-trip time of the protocol stack and the RTO value. The value must be greater than "RTOALPHA". In the case of the fixed value of the "RTOALPHA", the larger the value is, the less the link delay sensitivity is. None None Interval Type 0~100 0~100 per cent 25 25 SCTP linkNone Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RTOINIT RTO initial value BSC6900 ADD SCTPLNK(Optional) In the case of the fixed values of the "RTOMIN" and "RTPMAX", the larger the value is, the longer the check of the link is. None None Interval Type 500~60000 500~60000 ms 1000 1000 SCTP linkThe value to be set should be larger than the value of "RTOMIN" in "ADD SCTPLNK" but smaller than the value of "RTOMAX". Read & Write N (No impact on the UE in idle mode) Not involved Not involved The value should be greater than "RTOMIN" and smaller than "RTOMAX" in the command "ADD SCTPLNK".
RTOMAX RTO max value BSC6900 ADD SCTPLNK(Optional) In the case of the fixed value of the "RTOMIN", the larger the value is, the longer the check of the link is. None None Interval Type 500~60000 500~60000 ms 3000 3000 SCTP linkThe value to be set should be larger than the value of "RTOMIN" in "ADD SCTPLNK". Read & Write N (No impact on the UE in idle mode) Not involved Not involved The value should be greater than "RTOMIN" in the command "ADD SCTPLNK".
RTOMIN RTO min value BSC6900 ADD SCTPLNK(Optional) In the case of the fixed value of the "RTOMAX", the larger the value is, the longer the check of the link is. None None Interval Type 500~60000 500~60000 ms 1000 1000 SCTP linkThe value to be set should be smaller than the value of "RTOMAX" in "ADD SCTPLNK". Read & Write N (No impact on the UE in idle mode) Not involved Not involved The value should be smaller than "RTOMAX" in the command "ADD SCTPLNK".
RTPSWITCH Measure Link Delay Switch BSC6900 SET GCELLBASICPARA(Optional) Whether to measure the delay on the link between the BTSs that serve the calling MS and the called MS respectively. GBFD-115506AMR Coding Rate Threshold Adaptive Adjustment Enumeration Type DISABLE(Disable), ENABLE(Enable) DISABLE, ENABLE None DISABLE DISABLE Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RTTIPDCHMULTIPLEXTHRESH RTTI PDCH Multiplex Threshold BSC6900 SET GCELLPSCHM(Optional) Maximum number of RTTI TBFs that can be multiplexed on the PDCH. A PDCH can be assigned when the number of RTTI TBFs on it is smaller than the value of this parameter. This parameter is valid only when its value is smaller than or equal to "MSRD PDCH DL Multiplexing Threshold". GBFD-510805Latency Reduction Interval Type 10~80 10~80 None None 30 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RTTYPE Route Type BSC6900 ADD BTSIPRT(Mandatory) Type of the route GBFD-118601Abis over IP Enumeration Type NEXTHOP(Next Hop), OUTIF(Out Interface) NEXTHOP, OUTIF None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RUS Rate up step [kbps] BSC6900 ADD IPLOGICPORT(Optional) Logical port speed increase step. When detecting the available bandwidth increase through IPPM, the system increases the bandwidth of the logical port by using this parameter. None None Interval Type 0~1000 0~1000 None 5 5 IP logical port None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RUSPRD Rate up step adjust period [PLPRD] BSC6900 ADD IPLOGICPORT(Optional) Bandwidth increase step adjustment period. This parameter indicates the period to increase the bandwidth of the logical port. Note that the actual bandwidth increase step adjustment period is the packet drop ratio Statistics period multiplied by this parameter value. None None Interval Type 1~100 1~100 None 5 5 IP logical port None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RVer R-Version No. BSC6900 SET BTSAUTODLDACTINFO(Mandatory) R-version number of the BTS software GBFD-111202O&M of BTS Interval Type 0~999 0~999 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RXBW backward bandwidth BSC6900 ADD IPPATH(Mandatory) Receive bandwidth of IP path None None Interval Type 1~3000000 1~3000000 kbit/s None None IP path None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RxBw Backward Bandwidth BSC6900 ADD RSCGRP(Mandatory) Receive bandwidth. The parameter is valid when the " transmission resource group type " is ATM or " transmission resource group type " is IP and the " bandwidth mode " is FULL_DUPLEX. None None Interval Type 0~4000000 0~4000000 kbit/s None None Transmission resource group When "GRPT" in "ADD RSCGRP" is set to ATM or "BWMODE" is set to FULL_DUPLEX, this parameter is valid;The sum of "TxBw" and "RxBw" in "ADD RSCGRP" of upper class RSCGRP can not less than the "TxBw" and "AllBw" in "ADD RSCGRP"of lower class RSCGRP;The "TxBw" in "ADD RSCGRP" of upper class RSCGRP can not less than the "TxBw" in "ADD RSCGRP" of lower class RSCGRP, and the "RxBw" in "ADD RSCGRP" of upper class RSCGRP can not less than the "RxBw" in "ADD RSCGRP" of lower class RSCGRP. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RXLEVACCMIN Minimum Receiving level for Access BSC6900 SET GCELLSERVPARA(Optional) Minimum receiving power level for the MS in the cell to access the system. GBFD-114101GPRS Interval Type 0~63 0~63 None None 2 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RXLEVOFF Interfere HO Qual. Thres Offset for AMR FR BSC6900 SET GCELLAMRQUL(Optional) For AMR FR voice services, a fixed amount of offset is added to the corresponding grade of the received signal quality for the interference handover of non-AMR FR voice services. GBFD-115501AMR FR Interval Type 0~70 0~70 None None 5 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved For AMR calls, this parameter, together with "Interfere HO Qual Thres n for Non-AMR FR", is used in interference handover decision. An uplink interference handover is easily triggered if this parameter is set to a smaller value.
RXMIN RXLEV_ACCESS_MIN BSC6900 SET GCELLBASICPARA(Optional) Minimum level of received signals of the MS reported in the system message. GBFD-111101System Information Sending Interval Type 0~63 0~63 dB None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved If the value of this parameter is too small, the required level of received signals is low. Therefore, many MSs attempt to camp on the cell, thus increasing the load of the cell and the risk of call drops. In such a case, you must set the parameter based on the balance conditions of the uplink and downlink levels.
RXQCKFALLHOEN Rx_Level_Drop HO Allowed BSC6900 SET GCELLHOBASIC(Optional) Whether to use the emergency handover algorithm in case the receive level of the MSs drops rapidly, thus preventing call drops GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Enumeration Type NO(No), YES(Yes)NO, YES None None In dual-band networking mode for densely populated urban areas, the level drops rapidly due to multiple barriers. The propagation loss of the 1800 MHz frequency band is greater than the propagation loss of the 900 MHz frequency band. Considering the preceding factors, you can set this parameter to YES for the DCS1800 cell. Under normal conditions, set this parameter to No. Cell This parameter is valid only when "HOCTRLSWITCH" is set to HOALGORITHM1. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RXQUAL1 Interfere HO Qual. Thres 1 for Non-AMR FR BSC6900 SET GCELLAMRQUL(Optional) Threshold for the interference handover of Non-AMR FR voice services. AMRFR refers to Adaptive Multi-Rate Full Rate. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 0~70 0~70 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter is used in handover decision. An uplink interference handover is easily triggered if this parameter is set to a smaller value.
RXQUAL10 Interfere HO Qual. Thres 10 for Non-AMR FR BSC6900 SET GCELLAMRQUL(Optional) Threshold for the interference handover of Non-AMR FR voice services. AMRFR refers to Adaptive Multi-Rate Full Rate. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 0~70 0~70 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter is used in handover decision. An uplink interference handover is easily triggered if this parameter is set to a smaller value.
RXQUAL11 Interfere HO Qual. Thres 11 for Non-AMR FR BSC6900 SET GCELLAMRQUL(Optional) Threshold for the interference handover of Non-AMR FR voice services. AMRFR refers to Adaptive Multi-Rate Full Rate. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 0~70 0~70 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter is used in handover decision. An uplink interference handover is easily triggered if this parameter is set to a smaller value.
RXQUAL12 Interfere HO Qual. Thres 12 for Non-AMR FR BSC6900 SET GCELLAMRQUL(Optional) Threshold for the interference handover of Non-AMR FR voice services. AMRFR refers to Adaptive Multi-Rate Full Rate. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 0~70 0~70 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter is used in handover decision. An uplink interference handover is easily triggered if this parameter is set to a smaller value.
RXQUAL2 Interfere HO Qual. Thres 2 for Non-AMR FR BSC6900 SET GCELLAMRQUL(Optional) Threshold for the interference handover of Non-AMR FR voice services. AMRFR refers to Adaptive Multi-Rate Full Rate. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 0~70 0~70 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter is used in handover decision. An uplink interference handover is easily triggered if this parameter is set to a smaller value.
RXQUAL3 Interfere HO Qual. Thres 3 for Non-AMR FR BSC6900 SET GCELLAMRQUL(Optional) Threshold for the interference handover of Non-AMR FR voice services. AMRFR refers to Adaptive Multi-Rate Full Rate. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 0~70 0~70 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter is used in handover decision. An uplink interference handover is easily triggered if this parameter is set to a too small value.
RXQUAL4 Interfere HO Qual. Thres 4 for Non-AMR FR BSC6900 SET GCELLAMRQUL(Optional) Threshold for the interference handover of Non-AMR FR voice services. AMRFR refers to Adaptive Multi-Rate Full Rate. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 0~70 0~70 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter is used in handover decision. An uplink interference handover is easily triggered if this parameter is set to a smaller value.
RXQUAL5 Interfere HO Qual. Thres 5 for Non-AMR FR BSC6900 SET GCELLAMRQUL(Optional) Threshold for the interference handover of Non-AMR FR voice services. AMRFR refers to Adaptive Multi-Rate Full Rate. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 0~70 0~70 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter is used in handover decision. An uplink interference handover is easily triggered if this parameter is set to a smaller value.
RXQUAL6 Interfere HO Qual. Thres 6 for Non-AMR FR BSC6900 SET GCELLAMRQUL(Optional) Threshold for the interference handover of Non-AMR FR voice services. AMRFR refers to Adaptive Multi-Rate Full Rate. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 0~70 0~70 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter is used in handover decision. An uplink interference handover is easily triggered if this parameter is set to a too small value.
RXQUAL7 Interfere HO Qual. Thres 7 for Non-AMR FR BSC6900 SET GCELLAMRQUL(Optional) Threshold for the interference handover of Non-AMR FR voice services. AMRFR refers to Adaptive Multi-Rate Full Rate. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 0~70 0~70 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter is used in handover decision. An uplink interference handover is easily triggered if this parameter is set to a smaller value.
RXQUAL8 Interfere HO Qual. Thres 8 for Non-AMR FR BSC6900 SET GCELLAMRQUL(Optional) Threshold for the interference handover of Non-AMR FR voice services. AMRFR refers to Adaptive Multi-Rate Full Rate. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 0~70 0~70 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter is used in handover decision. An uplink interference handover is easily triggered if this parameter is set to a too small value.
RXQUAL9 Interfere HO Qual. Thres 9 for Non-AMR FR BSC6900 SET GCELLAMRQUL(Optional) Threshold for the interference handover of Non-AMR FR voice services. AMRFR refers to Adaptive Multi-Rate Full Rate. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 0~70 0~70 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter is used in handover decision. An uplink interference handover is easily triggered if this parameter is set to a smaller value.
RXUCHAINNO RXU Chain No BSC6900 ADD TRXBIND2PHYBRD(Mandatory) Number of the RXU chain to which the RXU belongs GBFD-111202O&M of BTS Interval Type 0~249 0~249 None None None TRX None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
RXUCHAINNO RXU Chain No. BSC6900 SET BTSRXUBP(Mandatory) Number of the RXU chain. The RXU chain No. is unique in one BTS. GBFD-111202O&M of BTS Interval Type 0~249 0~249 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RXUCHAINNO RXU Chain No. BSC6900 ADD BTSRXUBRD(Mandatory) Number of the RXU chain where the board is located GBFD-111202O&M of BTS Interval Type 0~249 0~249 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RXUIDTYPE RXU Index Type BSC6900 ADD TRXBIND2PHYBRD(Mandatory) Index type of the RXU GBFD-111202O&M of BTS Enumeration Type RXUNAME(By RXU Name), RXUPOS(By RXU Position No), SRNSN(By Subrack No) RXUNAME, RXUPOS, SRNSN None None None TRX None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
RXUIDTYPE RXU Index Type BSC6900 SET BTSRXUBP(Mandatory) Type of the RXU board index GBFD-111202O&M of BTS Enumeration Type RXUNAME(RXUName), RXUPOS(RXUPOS), SRNSN(SRNSN) RXUNAME, RXUPOS, SRNSN None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RXUNAME RXU Name BSC6900 ADD TRXBIND2PHYBRD(Mandatory) Name of the RXU GBFD-111202O&M of BTS String Type None 1~64 characters None None None TRX None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
RXUNAME RXU Name BSC6900 SET BTSRXUBP(Mandatory) Name of the RXU board. The RXU name is unique in one BTS. GBFD-111202O&M of BTS String Type None 1~64 characters None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RXUNAME RXU Name BSC6900 ADD BTSRXUBRD(Mandatory) Name of an RXU GBFD-111202O&M of BTS String Type None 1~64 characters None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RXUPOS RXU Chain Position BSC6900 ADD TRXBIND2PHYBRD(Mandatory) Position number of the RXU on the RXU chain GBFD-111202O&M of BTS Interval Type 1~6 1~6 None None None TRX None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
RXUPOS RXU Chain Position BSC6900 SET BTSRXUBP(Mandatory) Position No. of the RXU board on the RXU chain GBFD-111202O&M of BTS Interval Type 1~6 1~6 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RXUPOS RXU Board Position BSC6900 ADD BTSRXUBRD(Mandatory) Position of the RXU board on an RXU chain GBFD-111202O&M of BTS Interval Type 1~6 1~6 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
RXUTYPE RXU Board Type BSC6900 SET BTSRXUBP(Mandatory) Type of the RXU board GBFD-111202O&M of BTS Enumeration Type DRRU(DRRU), DRFU(DRFU), MRRU(MRRU), MRFU(MRFU), GRFU(GRFU), GRRU(GRRU), BTS3900E(BTS3900E) DRRU, DRFU, MRRU, MRFU, GRRU, GRFU, BTS3900E None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
S1SWITCH S1 value setting switch BSC6900 SET OPT(Optional) Whether to enable the switch to set the S1 value None None Enumeration Type OFF(OFF), ON(ON) OFF, ON None OFF OFF Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
S1VALUE S1 Value BSC6900 SET OPT(Optional) S1 sending value None None Interval Type 0~15 0~15 None None None Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SAADIS Special Analog Alm Enabled BSC6900 SET BTSDEMUBP(Optional) Whether to enable the special analog alarm.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. MRFD-210304Faulty Management Bit Field Type 48VDISABLE, RES0, RES1, RES2, TSDISABLED, HSDISABLED, RES3, RES4 48VDISABLE, RES0, RES1, RES2, TSDISABLED, HSDISABLED, RES3, RES4 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SAAF Special Analog Alarm Flag BSC6900 SET BTSAPMUBP(Optional) The value of this parameter consists of 32 bits, each of which determines whether to enable the corresponding special analog alarm. "0" indicates that the alarm is enabled, and "1" indicates that the alarm is disabled. When an item is selected, the corresponding analog alarm switch is disabled. The available items are BT1_DISABLE, AH_DISABLE, AT1_DISABLE, AT2_DISABLE, and BT2_DISABLE.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. GBFD-111202O&M of BTS Bit Field Type BT1_DISABLE, AH_DISABLE, AT1_DISABLE, AT2_DISABLE, BT2_DISABLE BT1_DISABLE(0), AH_DISABLE(1), AT1_DISABLE(2), AT2_DISABLE(3), BT2_DISABLE(4) None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SAALLNKN SAAL link No. BSC6900 ADD MTP3LNK(Mandatory)ADD ADJNODE(Mandatory) SAAL link No. of the SPU subsystem. It is the unique number of identifying one SAAL link. None None Interval Type 0~1399 0~1399 None None None SAAL linkNone Read & Write Not involved Not involved Not involved The parameter cannot be modified.
SAALTMR SAAL link connection timer BSC6900 SET MTP3TMR(Optional) This timer is a protection timer waiting for an SAAL response after a link setup request is sent to the SAAL. None None Interval Type 35000~120000 35000~120000 ms None None MTP3 linkNone Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SAICALLOWED Saic Allowed BSC6900 SET GCELLPWRBASIC(Optional) Whether an MS supports the SAIC function GBFD-118103Network Support SAIC Enumeration Type NO(No), YES(Yes)NO, YES None None NO Cell This parameter is valid only when "PWRBCDALLOWD" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SAICTHREDAPDTVALUE Power Control threshold Adjust for SAIC BSC6900 SET GCELLPWR2(Optional) Adjustment step of the downlink signal quality threshold in power control algorithm III for MSs that support SAIC. The network side uses a lower downlink signal quality threshold for SAIC-supported MSs in power control, thus lowering the transmit power of the corresponding BTS and reducing the interferences in the whole network. GBFD-118103Network Support SAIC Interval Type 0~2 0~2 None None 1 Cell This parameter is valid only when "SAICALLOWED" in "SET GCELLPWRBASIC" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SAICTHREDAPDTVALUE Power Control threshold Adjust for SAIC BSC6900 SET GCELLPWR3(Optional) Adjustment step of the downlink signal quality threshold in power control algorithm III for MSs that support SAIC. The network side uses a lower downlink signal quality threshold for SAIC-supported MSs in power control, thus lowering the transmit power of the corresponding BTS and reducing the interferences in the whole network. GBFD-118103Network Support SAIC Interval Type 0~4 0~4 None None 3 Cell This parameter is valid only when "PWRCTRLSW" in "SET GCELLPWRBASIC" is set to PWR3. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SALOG Special Analog Alarm Enabled BSC6900 SET BTSDPMUBP(Optional) The value of this parameter consists of five bits, which determines whether to enable the alarms. "0" indicates that the analog alarm is enabled, and "1" indicates that the analog alarm is disabled.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. MRFD-210304Faulty Management Bit Field Type T1_DISABLE, ET_DISABLE, ET1_DISABLE, ET2_DISABLE, T2_DISABLE T1_DISABLE, ET_DISABLE, ET1_DISABLE, ET2_DISABLE, T2_DISABLE None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SAMECVGCELLID Same Coverage Cell No BSC6900 SET GCELLDYNTURNOFF(Mandatory) Index of a cell with the same coverage as the current cell GBFD-111610Dynamic Cell Power Off Interval Type 0~2047 0~2047 None None None Cell This parameter is valid only when "TURNOFFENABLE" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SAMECVGCELLIDTYPE Same Coverage Cell Index Type BSC6900 SET GCELLDYNTURNOFF(Mandatory) Index type used when the command is executed GBFD-111610Dynamic Cell Power Off Enumeration Type BYNAME(By name), BYID(By index) BYNAME, BYID None None None Cell This parameter is valid only when "TURNOFFENABLE" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SAMECVGCELLLOADSTATTM Same Coverage Cell Load Stat. Time BSC6900 SET GCELLDYNTURNOFF(Optional) The system checks the load of the cell with the same coverage as the current cell and judges the check result once a minute. GBFD-111610Dynamic Cell Power Off Interval Type 1~16 1~16 None None 5 Cell This parameter is valid only when "TURNOFFENABLE" is set to YES. The following condition must be met: "SAMECVGCELLLOADSTATTM" >= "SAMECVGCELLLOADLASTTM". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SAMECVGCELLLOADTHRD Same Coverage Cell Load Threshold BSC6900 SET GCELLDYNTURNOFF(Optional) The cells that can be disabled are allowed to be disabled only when the same coverage cell load is always below the threshold. GBFD-111610Dynamic Cell Power Off Interval Type 0~100 0~100 per cent None 50 Cell This parameter is valid only when "TURNOFFENABLE" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SAMECVGCELLNAME Same Coverage Cell Name BSC6900 SET GCELLDYNTURNOFF(Mandatory) Name of the same coverage cell GBFD-111610Dynamic Cell Power Off String Type None 1~64 characters None None None Cell This parameter is valid only when "TURNOFFENABLE" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SAMULFRM SACCH Multi-Frames BSC6900 SET GCELLCCBASIC(Optional) This parameter is used by the BTS to inform the BSC of radio link connection failure.When the BTS receives the SACCH measurement report from the MS, the counter for determining whether a radio link is faulty is set to the value of this parameter. Each time the BTS fails to decode the SACCH measurement report sent by the MS, the counter decreases by 1. If the BTS successfully decodes the SACCH measurement report, the counter increases by 2.When the value of this parameter is 0, the BTS regards the radio link as faulty. The BTS sends a connection failure indication message to the BSC. The number of SACCH multi-frames and the radio link failure counter in the system message specify the radio link failure time on the uplink and that on the downlink respectively. The judgment standard is whether the measurement report in SACCH is correctly decoded. GBFD-111004Radio Dedicated Channel Management Interval Type 0~63 0~63, step: 480 ms None 32 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SAS Special Alarm Switcher BSC6900 SET BTSDPMUBP(Optional) The value of this parameter consists of three bits, which determines whether to enable the alarms. "0" indicates that the alarm is enabled, and "1" indicates that the alarm is disabled.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. MRFD-210304Faulty Management Bit Field Type WATER_IMMERSED, SMOG, GM_DISABLE WATER_IMMERSED, SMOG, GM_DISABLE None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SASE Special Alm Switch Enabled BSC6900 SET BTSDEMUBP(Optional) Whether to enable the special alarm switch.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. MRFD-210304Faulty Management Bit Field Type WIDISABLE, SMDISABLE, IMDISABLE, GMDISABLE WIDISABLE, SMDISABLE, IMDISABLE, GMDISABLE None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SASV Special Alm Switch Valid vol. Level BSC6900 SET BTSDEMUBP(Optional) Level specifications of special Boolean value alarms. Two specifications are available: high level and low level. By default, only alarms of the door status sensor are low level, and alarms of the water sensor, smoke sensor, and infrared sensor are high level.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. MRFD-210304Faulty Management Bit Field Type WILOW, SMLOW, IMLOW, GMLOW WILOW, SMLOW, IMLOW, GMLOW, None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SAVEENABLED Energy Saving Support BSC6900 SET BTSDOMUBP(Optional) Whether to enable the energy saving function of the TRX GBFD-111202O&M of BTS Enumeration Type NO(NO), YES(YES) NO, YES None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SBAF Special Bool Alarm Flag BSC6900 SET BTSAPMUBP(Optional) Whether to enable the special Boolean alarms, that is, water sensor alarm (bit 0), smog sensor alarm (bit 1), and door sensor alarm (bit 2). All the Boolean alarms are enabled by default. "0" indicates that the alarm is enabled, and "1" indicates that the alarm is disabled.The available items are WS_DISABLE, SS_DISABLE, and GS_DISABLE~2.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. GBFD-111202O&M of BTS Bit Field Type WS_DISABLE, SS_DISABLE, GS_DISABLE WS_DISABLE(0), SS_DISABLE(1), GS_DISABLE(2) None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SBTSID First BTS Index BSC6900 COL SYNCINFO(Mandatory) Number of the BTS. The BTS is numbered uniquely in a BSC. GBFD-118201Soft-Synchronized Network Interval Type 0~2047 0~2047 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None.
SBTSNAME First BTS Name BSC6900 COL SYNCINFO(Mandatory) Name of the BTS. The BTS is named uniquely in a BSC. GBFD-118201Soft-Synchronized Network String Type None 1~64 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None.
SCALEORDER SCALE_ORDER BSC6900 SET GCELLCCUTRANSYS(Optional) This parameter indicates that when the MS reports the EMR, it adds the value of this parameter to the received signal level, and then converts the result into the RXLEV value. For details, see GSM Rec. 05.08.If the SCALE_Order reported by the MS is 10 dBm, level values 0-63 map with -100 dBm to -37 dBm.If the SCALE_Order reported by the MS is 0 dBm, level values 0-63 map with -110 dBm to -47 dBm.If the SCALE_Order reported by the MS is Automatic, the MS chooses the least SCALE while ensuring that the MS can report the most strong level. GBFD-117501Enhanced Measurement Report(EMR) Enumeration Type ADD0dB(+0dB), ADD10dB(+10dB), Automatic(Automatic) ADD0dB, ADD10dB, Automatic None None ADD0dB Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SCDSCP DSCP of STREAM[QoS] BSC6900 SET BSCPSTCDSCPMAP(Optional) DSCP corresponding to the streaming service. GBFD-118603Gb over IP Interval Type 0~63 0~63 None None 26 BSC None Read & Write Not involved Not involved Not involved None
SCELLFILTER Serving cell filter length mr number BSC6900 SET GCELLHOFAST(Optional) When the network receives measurement reports, in consideration of the accuracy of a single measurement report, the measurement values in certain measurement reports are filtered to represent the radio operating environment. The parameter specifies the number of measurement reports used for filtering measurement information of the serving cell. GBFD-510102Fast Move Handover Interval Type 1~20 1~20, step:480 for TCH and 470 for SDCCH ms None 4 Cell This parameter is valid only when "QUICKHOEN" in "SET GCELLHOBASIC" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SCELLID First Cell Index BSC6900 ADD NCELL(Mandatory)COL SYNCINFO(Mandatory) Number of the cell where the TRX reside. The cell is numbered uniquely in a BSC. MRFD-210301Configuration Management Interval Type 0~2047 0~2047 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None.
SCELLNAME First Cell Name BSC6900 ADD NCELL(Mandatory)COL SYNCINFO(Mandatory) Name of cell 1.GBFD-111202O&M of BTS String Type None 1~64 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None.
SCHEME Coding Scheme BSC6900 SET GCELLSBC(Optional)ADD GSMSCB(Mandatory) A key parameter that indicates the coding scheme of a simple cell broadcast message GBFD-113602Simplified Cell Broadcast Enumeration Type GERMAN(GERMAN), ENGLISH(ENGLISH), ITALIAN(ITALIAN), FRENCH(FRENCH), SPANISH(SPANISH), DUTCH(DUTCH), SWEDISH(SWEDISH), DANISH(DANISH), PORTUGUESE(PORTUGUESE), FINNISH(FINNISH), NORWEGIAN(NORWEGIAN), GREEK(GREEK), TURKISH(TURKISH), HUNGARIAN(HUNGARIAN), POLISH(POLISH), GB2312(GB2312), KOI8-R(Cyrillic KOI8-R), KOI8-U(Cyrillic KOI8-U), KOI8(Cyrillic KOI8), WINDOWS-1251(Cyrillic Windows), ASMO_449(Arabic ASMO), WINDOWS-1256(Arabic Windows), WINDOWS-874(Thai Windows), WINDOWS-1253(Greek Windows), WINDOWS-1254(Turkish Windows), WINDOWS-1255(Hebrew Windows), WINDOWS-1257(Baltic Windows), WINDOWS-1250(Eastern European Windows), WINDOWS-1252(Western European Windows), BINARY(BINARY), UCS2(UCS2), RCS-1(Reserved Code Scheme 1), RCS-2(Reserved Code Scheme 2), RCS-3(Reserved Code Scheme 3), RCS-4(Reserved Code Scheme 4), RCS-5(Reserved Code Scheme 5) GERMAN, ENGLISH, ITALIAN, FRENCH, SPANISH, DUTCH, SWEDISH, DANISH, PORTUGUESE, FINNISH, NORWEGIAN, GREEK, TURKISH, HUNGARIAN, POLISH, GB2312, KOI8-R, KOI8-U, KOI8, WINDOWS-1251, ASMO_449, WINDOWS-1256, WINDOWS-874, WINDOWS-1253, WINDOWS-1254, WINDOWS-1255, WINDOWS-1257, WINDOWS-1250, WINDOWS-1252, BINARY, UCS2, RCS-1, RCS-2, RCS-3, RCS-4, RCS-5 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SCHNNO Sub Channel No. BSC6900 STR BTSTST(Optional) Number of the sub-channel GBFD-111202O&M of BTS Interval Type 0~7 0~7 None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SCMD Command String BSC6900 ADD SUBTSK(Mandatory)ADD SUBCMD(Mandatory) Command string of the scheduled subtask. This command can be only a service command, and the system command cannot be added to the scheduled subtask. GBFD-111203O&M of BSC Any Type None Valid command string, without the ';'an the end of the string. None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SCOPETYPE Scope Type BSC6900 SET GMRSCOPE(Mandatory) Type of querying the scope of collecting the measurement report GBFD-111203O&M of BSC Enumeration Type BYBTSID(By BTS ID), BYCELLID(By Cell ID) BYBTSID, BYCELLIDNone None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SCPIDX Subrack Communication Path Index BSC6900 ADD SRCONPATH(Optional) Indicates the index of the inter-subrack connection path. GBFD-111203O&M of BSC Interval Type 0~23 0~23 None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SCRAMBLE Scrambling code or cell parameter id BSC6900 ADD GEXT3GCELL(Optional)SET GCELLHOFDDBA2(Mandatory) Scrambling code of a 3G cell. The scrambling code is used to differentiate terminals or cells. It is used after spread spectrum. Therefore, it does not change the bandwidth of signals, but only distinguishes the signals from different sources. Through scrambling, multiple transceivers can use the same codes for spread spectrum. Scrambling is used to distinguish terminals on the uplink and to distinguish cells on the downlink. GBFD-114301GBFD-114302 GSM/WCDMA InteroperabilityGSM/TD-SCDMA Interoperability Interval Type 0~511 0~511 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SCRAMBLESW Scramble Switch BSC6900 SET E1T1(Optional) Scramble switch None None Enumeration Type OFF(OFF), ON(ON) OFF, ON None None None E1/T1 port None Read & Write Y BSC6900 Interrupt the service until negotiate successfully again. The setting of DIP switches must be consistent with that on the interconnected side.
SCRAMBLESW Scramble switch BSC6900 SET OPT(Optional) Scramble switch None None Enumeration Type OFF(OFF), ON(ON) OFF, ON None None None Board None Read & Write Y BSC6900 Interrupt the service until negotiate successfully again. The setting of this parameter must be consistent with that on the peer.
scsn Start Serial No. BSC6900 EXP ALMLOG(Optional)STAALMLOG(Optional) Start serial number of the alarm record MRFD-210304Faulty Management Interval Type 1~2147483646 1~2147483646 None 1 1 RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SCTPLNKN SCTP link No. BSC6900 ADD SCTPLNK(Mandatory)ADD M3LNK(Mandatory) SCTP link No. of one subsystem.This number identify an SCTP link uniquely. None None Interval Type 0~1199 0~1199 None None None SCTP linkNone Read & Write Not involved Not involved Not involved The parameter cannot be modified.
SD Start Date BSC6900 ADD SUBTSK(Mandatory) Date when the scheduled task is started GBFD-111203O&M of BSC Compound Type year, month, date 2000-1-1~2037-12-31None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
sd Start Date BSC6900 EXP ALMLOG(Optional) Start date of the alarm record. By default, the start date is 2000-01-01. MRFD-210304Faulty Management Compound Type year, month, day 2000-1-1~2037-12-31None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
sd Start Date BSC6900 STA ALMLOG(Optional) Start date of the alarm record. By default, the start date is 2000-01-01. MRFD-210304Faulty Management Compound Type year, month, day 2000-1-1~2037-12-31None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
sd Alarm Log Saved Time[Day] BSC6900 SET ALMCAPACITY(Optional) Maximum number of days for storing history alarms MRFD-210304Faulty Management Interval Type 7~90 7~90 d None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SDALMTHD SD Alarm Threshold BSC6900 SET MSP(Optional) SD alarm triggering threshold GBFD-111701Board Switchover Enumeration Type 1E-3, 1E-4, 1E-5, 1E-6, 1E-7, 1E-8, 1E-9 1E-3, 1E-4, 1E-5, 1E-6, 1E-7, 1E-8, 1E-9 None 1.00E-06 1.00E-06 MSP protect group None Read & Write Y BSC6900 Interrupt the service until negotiate successfully again. The setting of this parameter must be negotiated with that on the interconnected side.
SDATE Start Date BSC6900 STR BTSLOG(Optional) Start date GBFD-111202O&M of BTS Compound Type year, month, day 2000-01-01~2050-12-31 None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SDAY Start date BSC6900 SET TZ(Mandatory) Start date of the daylight saving time (DST) MRFD-210301Configuration Management Interval Type 1~31 1~31 d None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved 1. If you set the start date or end date of DST to a day of the week after a specific date, the specific date must be six days or more days prior to the last day of the month. For example, the last day of October is the 31st day. Then, the specific date cannot be later than the 25th (31 6) day. If you set the specific date to Tuesday after 26 October, this date is not included in the November of 2005. Therefore, the specific date is invalid. This date in 2006, however, is October 31, which is valid. As a result, you must follow this principle to ensure that a specific data is always valid.2. You are not allowed to set the start date or end date of DST to February 29. This is because that the local time changes between DST and non-DST. In a non-leap year, February 29 does not exist. Therefore, the local time cannot change between the start date and the end date.3. The start month and end month of DST cannot be the same.
SDCCHNUM SDCCHChannelNumber BSC6900 ADD GCELLQUICKSETUP(Optional) Number of SDCCH channels. Rules for SDCCH channel allocation: 1. Allocate channels 1 and 3 of main frequency B preferentially. 2. Allocate channels 1, 3, 5, and 7 according to the physical position order of the frequencies. Thus, the maximum number of SDCCH channels is (actual number of frequencies - 1) *4+2. GBFD-510701Compact BTS Automatic Configuration and Planning Interval Type 1~191 1~191 None 1 None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SDDROPSTATDLLEV DL Level Threshold for SDCCH Call Drop BSC6900 SET GCELLOTHEXT(Optional) Level threshold for measuring the number of call drops on SDCCH. When call drop occurs on the SDCCH, the BSC determines whether the downlink receive level is lower than this threshold. If the downlink receive level is lower than this threshold and the TA is smaller than the TA threshold of the serving cell, the number of call drops on SDCCH (receive level) is incremented by one. GBFD-111004Radio Dedicated Channel Management Interval Type 0~63 0~63 dB 6 6 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The level values 0 through 63 map to -110 dBm to -47 dBm. A smaller value indicates a lower receive level.
SDDROPSTATDLQUAL DL Quality Threshold for SDCCH Call Drop BSC6900 SET GCELLOTHEXT(Optional) Quality threshold for measuring the number of call drops on SDCCH. When call drop occurs on the SDCCH, the BSC determines whether the downlink quality level multiplied by 10 is higher than this threshold. If all the following four conditions are met, the number of call drops on SDCCH (receive quality) is incremented by one. First, the downlink quality level multiplied by 10 is higher than this threshold. Second, the TA is smaller than the TA threshold of the serving cell. Third, the uplink level is higher than "UL Level Threshold for SDCCH Call Drop". Finally, the downlink level is lower than "DL Level Threshold for SDCCH Call Drop". GBFD-111004Radio Dedicated Channel Management Interval Type 0~70 0~70 None None 55 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The parameter value corresponds to RQ (quality level: 0 to 7) multiplied by 10. A greater value indicates a poorer receive quality.
SDDROPSTATULLEV UL Level Threshold for SDCCH Call Drop BSC6900 SET GCELLOTHEXT(Optional) Level threshold for measuring the number of call drops on SDCCH. When call drop occurs on the SDCCH, the BSC determines whether the uplink receive level is lower than this threshold. If the uplink receive level is lower than this threshold and the TA is smaller than the TA threshold of the serving cell, the number of call drops on SDCCH (receive level) is incremented by one. GBFD-111004Radio Dedicated Channel Management Interval Type 0~63 0~63 dB 6 6 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The level values 0 through 63 map to -110 dBm to -47 dBm. A smaller value indicates a lower receive level.
SDDROPSTATULQUAL UL Quality Threshold for SDCCH Call Drop BSC6900 SET GCELLOTHEXT(Optional) Quality threshold for measuring the number of call drops on SDCCH. When call drop occurs on the SDCCH, the BSC determines whether the uplink quality level multiplied by 10 is higher than this threshold. If all the following four conditions are met, the number of call drops on SDCCH (receive quality) is incremented by one. First, the uplink quality level multiplied by 10 is higher than this threshold. Second, the TA is smaller than the TA threshold of the serving cell. Third, the uplink level is higher than "UL Level Threshold for SDCCH Call Drop". Finally, the downlink level is lower than "DL Level Threshold for SDCCH Call Drop". GBFD-111004Radio Dedicated Channel Management Interval Type 0~70 0~70 None None 55 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The parameter value corresponds to RQ (quality level: 0 to 7) multiplied by 10. A greater value indicates a poorer receive quality.
SDDYN SDCCH Dynamic Allocation Allowed BSC6900 SET GCELLBASICPARA(Optional) Whether to allow SDCCH dynamic allocation. This parameter specifies whether the dynamic adjustment between TCHs and SDCCHs is allowed. GBFD-113001SDCCH Dynamic Adjustment Enumeration Type NO(No), YES(Yes)NO, YES None None YES Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The SDCCH dynamic adjustment converts the TCHs to the SDCCHs, this reduces the available TCHs and decreases the TCH traffic bearing capability.
SDENABLE SD Enable BSC6900 SET MSP(Optional) Enable SD GBFD-111701Board Switchover Enumeration Type DISABLE, ENABLEDISABLE, ENABLE None None DISABLE MSP protect group None Read & Write Y BSC6900 Interrupt the service until negotiate successfully again. The setting of this parameter must be negotiated with that on the interconnected side.
SDFASTHOSWITCH SD Quick Ho BSC6900 SET GCELLSOFT(Optional) Whether to enable the SDCCH quick handover test function. If this parameter is set to Yes, the BSC initiates intra-cell SDCCH handover as soon as the MSC issues an encrypted command to the MS. Thus, the forwarding encrypted signaling can be transmitted and received on a new signaling channel. In this way, the network security is improved. GBFD-110608SDCCH Handover Enumeration Type OFF(Off), ON(On) OFF, ON None None OFF Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SDFLAG Shut Down Enabled BSC6900 SET GTRXDEV(Optional) Whether to enable the BSC to shut down the power amplifier of the TRX automatically to save power when the BTS switches from the mains to batteries GBFD-111605Active Backup Power Control Enumeration Type DISABLE(Disable), ENABLE(Enable) DISABLE, ENABLE None None None TRX None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SDHOMININTV Min Interval for SDCCH Hos BSC6900 SET GCELLHOCTRL(Optional) After a new SDCCH is assigned to an MS, the MS can be handed over to another channel only if the time during which the MS occupies the SDCCH is longer than the period specified by this parameter. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 0~60 0~60 s None 2 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SDMRCUTNUM SdMrCutNum BSC6900 SET GCELLPWR3(Optional) Maximum number of discarded MRs allowed on the SDCCH in a power control period. GBFD-117601HUAWEI III Power Control Algorithm Interval Type 0~5 0~5 None None 1 Cell This parameter is valid only when "PWRCTRLSW" in "SET GCELLPWRBASIC" is set to PWR3. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SDPUNTIME Penalty time on fast moving HO BSC6900 ADD GEXT2GCELL(Optional) Period in which level penalty is performed on the neighboring cells of the cell where a fast-moving MS is located. The neighboring cells must be located at the Macro, Micro, or Pico layer other than the Umbrella layer. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 0~255 0~255 s None 40 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SDPUNVAL Penalty on fast moving HO BSC6900 ADD GEXT2GCELL(Optional) Level value of the penalty that is performed on the neighboring cells of the cell where a fast-moving MS is located. The neighboring cells must be located at the Macro, Micro, or Pico layer other than the Umbrella layer. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 0~63 0~63 dB None 30 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SDSCP DSCP of Signalling BSC6900 SET BSCPSTCDSCPMAP(Optional) DSCP corresponding to the signalling. GBFD-118603Gb over IP Interval Type 0~63 0~63 None None 56 BSC None Read & Write Not involved Not involved Not involved None
SDSFPRI SDSF Priority BSC6900 SET MSP(Optional) Specifies the SF and SD event priority GBFD-111701Board Switchover Enumeration Type HIGH(HIGH), LOW(LOW) HIGH, LOW None None None MSP protect group None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
SDT Shutdown Temperature BSC6900 SET BTSAPMUBP(Optional) High temperature threshold for triggering power shutdown of the battery. If the power shutdown upon battery high temperature is enabled and the battery temperature is higher than the value of this parameter, the battery is automatically powered off.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. GBFD-111202O&M of BTS Interval Type 40~70 40~70 degree Celsius None 53 BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SDTMWDALMDIS Sliding Time Window Alarm Disappear BSC6900 ADD BTSALMMGMRULE(Mandatory) Sliding time window for collecting statistics on the alarms that disappear in a specified period of time MRFD-210304Faulty Management Interval Type 0~65535 0~65535 s None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SDTMWDALMOC Sliding Time Window Alarm Occurrence BSC6900 ADD BTSALMMGMRULE(Mandatory) Sliding time window for collecting statistics on the alarms that occur in a specified period of time MRFD-210304Faulty Management Interval Type 0~65535 0~65535 s None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SDV Shutdown Voltage BSC6900 SET BTSAPMUBP(Optional) Low voltage threshold for triggering power shutdown of the battery. If the power shutdown upon low voltage is enabled and the load voltage is lower than the value of this parameter, the battery is automatically powered off.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. GBFD-111202O&M of BTS Interval Type 350~553 35~55.3 (step: 0.1) V None If "Power System Type" is "APM30" and the BTS type is one of the BTS3900 series, the recommended value is "465". If "Power System Type" is "SC48200", the recommended value is "460". Otherwise, the recommended value is "430". BTS The value of this parameter must be smaller than "DC Voltage Lower Threshold". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SEARCH3G 3G Search PRIO BSC6900 SET GCELLCCUTRANSYS(Optional) Whether to allow the MS to search for a 3G cell when the BSIC must be decoded. GBFD-117501Enhanced Measurement Report(EMR) Enumeration Type NO(No), YES(Yes)NO, YES None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SELFVERSION Self Version BSC6900 SET BTSLOADCTRL(Mandatory) Self Software Version GBFD-111202O&M of BTS String Type None 1~63 characters None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
Send2QuterFlag Support Sent 2QUATER BSC6900 SET OTHSOFTPARA(Optional) Whether the SI Type 3 message contains the 2QUATER indicator. GBFD-111101System Information Sending Enumeration Type NO, YES NO, YES None None YES BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SendBssInvokeTrace Spt BSS Invoke Trace Rpt[end2end user trace] BSC6900 SET OTHSOFTPARA(Mandatory) Whether to report BSS INVOKE TRACE message. When the parameter is set to YES, the BSC sends a BSS INVOKE TRACE message to the MSC if receiving an MSC INVOKE TRACE or BSS INVOKE TRACE message from MSC in the case of an outgoing BSC handover. If the BSC does not receive the message, the BSC does not send a BSS INVOKE TRACE message to the MSC. GBFD-116401End-to-End MS Signaling Tracing Enumeration Type NO(No), YES(Yes)NO, YES None None NO BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SENDCMAFTERINBSCHO Send Classmark ENQ Result to MSC Enabled BSC6900 SET GCELLSOFT(Optional) Whether to report the classmark queried by the BSC to the MSC GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Enumeration Type NO(No), YES(Yes)NO, YES None None NO Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SendConfusionToMSC Sent Confusion Message to MSC BSC6900 SET AITFOTHPARA(Optional) Whether to send a CONFUSION message to the MSC. This parameter specifies whether to send a message carrying fault location information to the MSC if the BSC receives a message that cannot be decoded over the A interface. GBFD-111804A Interface Protocol Process Enumeration Type NO(No), YES(Yes)NO, YES None None NO MSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter should be set on the basis of the negotiation with the MSC at the peer end.
SENDDOWNLINKMESSAGE Send Downlink Message after Hanging up BSC6900 SET OTHSOFTPARA(Optional) If this parameter is set to No, the BSC responds with an SAPI N'Reject message against the DL short message after hangup. GBFD-110203Point To Point Short Message Service (TS21, TS22) Enumeration Type NO(No), YES(Yes)NO, YES None None YES BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SENDFACCHNOTPRI Send FACCH Notification Priority BSC6900 SET GCELLGSMR(Optional) Priority of the notification message transmission on the FACCH. From high to low, the priorities are A, B, 0, 1, 2, 3, 4. No priority is the lowest. When the priority of the group call is higher than or equal to the value specified by this parameter, the notification message is sent on the FACCH. GBFD-510307Group Call EMLPP Enumeration Type NoPriority(No Priority), Priority4(Priority 4), Priority3(Priority3), Priority2(Priority 2), Priority1(Priority 1), Priority0(Priority 0), PriorityB(Priority B), PriorityA(Priority A) NoPriority, Priority4, Priority3, Priority2, Priority1, Priority0, PriorityB, PriorityA None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SENDFACCHPAGPRI Send FACCH Paging Priority BSC6900 SET GCELLGSMR(Optional) Priority of the paging message transmission on the FACCH. From high to low, the priorities are A, B, 0, 1, 2, 3, 4. No priority is the lowest. When the priority of the group call is higher than the value specified by this parameter, the paging message is sent on the FACCH. GBFD-510307Group Call EMLPP Enumeration Type NoPriority(No Priority), Priority4(Priority 4), Priority3(Priority3), Priority2(Priority 2), Priority1(Priority 1), Priority0(Priority 0), PriorityB(Priority B), PriorityA(Priority A) NoPriority, Priority4, Priority3, Priority2, Priority1, Priority0, PriorityB, PriorityA None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SENDSI2TERFLAG Send System Information 2ter BSC6900 SET OTHSOFTPARA(Optional) Whether the BSC sends the System Information Type 2ter message. GBFD-111101System Information Sending Enumeration Type NO(No), YES(Yes)NO, YES None None NO BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SENDSI5TERFLAG Send System Information 5ter BSC6900 SET OTHSOFTPARA(Optional) Whether the BSC sends the System Information Type 5ter message. GBFD-111101System Information Sending Enumeration Type NO(No), YES(Yes)NO, YES None None YES BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SendUtranECSCFlag Send 3G Class Flag BSC6900 SET OTHSOFTPARA(Optional) Whether the SI Type 3 message contains the 3G Early Classmark Sending Restriction field. The 3G Early Classmark Sending Restriction field is used to notify the MS of whether the early classmark message contains the 3G classmark message. This parameter is valid for dual-mode MSs and is invalid for single-mode MSs. GBFD-111101System Information Sending Enumeration Type NO, YES NO, YES None None YES BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SEPARATEPOS SeparatePos BSC6900 SPT BTSRXUCHAIN(Mandatory) Split position on the RXU chain GBFD-111202O&M of BTS Interval Type 1~5 1~5 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SEPERATEMODE Separate Mode BSC6900 ADD BTS(Optional) Whether to enable the BTS to support the separation between the physical and logical GBFD-111202O&M of BTS Enumeration Type SUPPORT(Support), UNSUPPORT(Not Support) SUPPORT, UNSUPPORT None UNSUPPORT UNSUPPORT BTS None Read & Write Y BTS Less than 5 minutes None
SERCMDPORT The Command Port of FTPS Server BSC6900 SET FTPSSRV(Mandatory) Number of the command listening port of the server. You should not use any port number occupied by other applications. GBFD-111203O&M of BSC Interval Type 1024~65535 1000~65535 None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SERDATAPORT The Source Date Port of FTPS Server BSC6900 SET FTPSSRV(Mandatory) Number of the data port of the server in active mode. You should not use any port number occupied by other applications. GBFD-111203O&M of BSC Interval Type 1024~65535 1000~65535 None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SERIALNO Device serial No. BSC6900 ADD BTSRETANT(Mandatory) Delivery serial number of the RET antenna MRFD-210602Remote Electrical Tilt String Type None 1~17 characters None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ServerIP FTP Server IP Address BSC6900 ADD FTPSCLTDPORT(Mandatory) IP address of the FTP server to be visited by the FTP client GBFD-111203O&M of BSC IP Address Type None 0.0.0.0~255.255.255.255 None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ServiceMode Service mode BSC6900 SET BSCBASIC(Optional) Service mode of the BSC GBFD-118602A over IP Enumeration Type SEPARATE(Separate), TOGETHER(Together), AIP(AIP) SEPARATE, TOGETHER, AIP None SEPARATE SEPARATE BSC6900None Read & Write Y BSC6900 Less than 10 minutes None
SERVICEMODE Service Type BSC6900 ADD BTS(Optional) Service bearer mode of the BTS GBFD-118601Abis over IP Enumeration Type TDM, HDLC, HDLC_HubBTS, IP TDM, HDLC, HubBTS, IP None TDM TDM BTS None Read & Write Y BTS Less than 5 minutes None
SERVICEMODE Service Type BSC6900 ADD BTSAUTOPLAN(Mandatory) Service bearer mode of the BTS GBFD-510601PICO Automatic Configuration and Planning Enumeration Type TDM, HDLC, IP TDM, HDLC, IP None None None BTS The value range of this parameter varies with "BTS Type". Different types of BTSs support different types of services. Read & Write Y BTS Less than 5 minutes None
ServiceName Service Name BSC6900 EXP LOG(Optional) Name of the command function GBFD-111203MRFD-210305 O&M of BSCSecurity Management Enumeration Type SYSTEM(System Command), CONFIG(Configuration Management), MAINTAIN(Maintenance Management), STAT(Statistic Measurement), ALARM(Alarm Management) SYSTEM, CONFIG, MAINTAIN, STAT, ALARM None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
5/5/2014
Confidential Information of Huawei.
No Spreading without Permission
Page17of42
226347869.xls.ms_office Security Level:
SERVICETYPE Service Type BSC6900 SET BTSVLAN(Mandatory) Service type of the BTS. The QoS processing depends on the DSCP, VLAN ID, and VLAN priority that vary according to the service type. GBFD-118601Abis over IP Enumeration Type OML(OML), RSL(RSL), EML(EML), ESL(ESL), CSVOICE(CS Voice), CSDATA(CS Data), PSHIGHPRI(PS High PRI), PSLOWPRI(PS Low PRI), OTHERDATA(Other Data) OML, RSL, EML, ESL, CSVOICE, CSDATA, PSHIGHPRI, PSLOWPRI, OTHERDATA None None None BTS None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
SETDIESELENGINEENABLED Diesel engine configure enabled BSC6900 SET BTSAPMUBP(Optional)SET BTSDPMUBP(Optional) Whether to enable the diesel engine parameters to be configured GBFD-111202O&M of BTS Enumeration Type NO(NO), YES(YES) NO, YES None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SETENVPARAENABLED ENV TEMP CFG Enabled BSC6900 SET BTSAPMUBP(Optional) Whether to enable the environment temperature alarm parameters of the APMU to be configured. The APMU of the APM30 type does not support this parameter.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. GBFD-111202O&M of BTS Enumeration Type NO(NO), YES(YES) NO, YES None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SETENVPARAENABLED ENV TEMP CFG Enabled BSC6900 SET BTSDPMUBP(Optional) Whether to enable the environment temperature parameters to be configured.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. GBFD-111202O&M of BTS Enumeration Type NO(NO), YES(YES) NO, YES None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SETHUMPARAENABLED Environment Humidity Configure Enabled BSC6900 SET BTSAPMUBP(Optional)SET BTSDPMUBP(Optional) Whether to enable the environment humidity alarm parameters of the board to be configured.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. GBFD-111202O&M of BTS Enumeration Type NO(NO), YES(YES) NO, YES None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SFPPORTNO SFP Port No BSC6900 ADD BTSSFPMODE(Mandatory) Number of the SFP port. If the switching relation is added on the SFP port, it indicates that the SFP port is used to connect the BBU and no RXU chain or ring can be configured on the port. GBFD-111202O&M of BTS Interval Type 0~2 0~2 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SGSNCAP Configure Capacity<K User Number> BSC6900 ADD SGSNNODE(Optional) Available capacity of the SGSN. GBFD-119701SGSN Pool Interval Type 0~65535 0~65535 None 1800 1800 BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The ratio of the subscribers accessing this SGSN is affected when this parameter is modified.
SGSNFLG SGSN FLAG BSC6900 ADD ADJNODE(Mandatory) It is valid when the node type is set to IUPS. If the parameter is set to No, it indicates the GGSN. The dpx needs not to be configured. None None Enumeration Type NO(GGSN), YES(SGSN) NO, YES None None None Adjacent node When the value of "NODET" in "ADD ADJNODE" is set to IUPS, this parameter is valid. Read & Write Not involved Not involved Not involved The parameter cannot be modified.
SGSNNAME SGSN Name BSC6900 ADD SGSN(Mandatory) Name of the SGSN MRFD-210301Configuration Management String Type None 1~20 characters None None None BSC None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
SGSNNRILEN SGSN NRI length BSC6900 ADD GCNOPERATOR(Mandatory) Length of the NRI or NULL-NRI. The length determines the maximum value of the NRI and NULL-NRI. GBFD-119701SGSN Pool Interval Type 1~10 1~10 None None None BSC6900This parameter is valid when "SGSNPOOLALLOW" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SGSNNULLNRI SGSN NullNRI Value BSC6900 ADD GCNOPERATOR(Optional) Special NRI. Each SGSN pool has one NULL-NRI. When the NRI value in the TLLI of the MS uplink/downlink service data equals NULL-NRI, the BSC reselects an SGSN for the MS. GBFD-119701SGSN Pool Interval Type 0~1023 0~1023 None 0 0 BSC6900This parameter is valid when "SGSNPOOLALLOW" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SGSNPOOLALLOW Allow SGSN Pool BSC6900 ADD GCNOPERATOR(Optional) Whether to enable the SGSN pool function GBFD-119701SGSN Pool Enumeration Type NO(No), YES(Yes)NO, YES None NO NO BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SGSNR Protocol Version Supported by SGSN BSC6900 SET GCELLPSBASE(Optional) Protocol version supported by the SGSN. GBFD-114101GPRS Enumeration Type 0( Release 98 or older), 1(Release 99 onwards) Release 98 or older, Release 99 onwards None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SGSNSTATUS SGSN Management Status BSC6900 ADD SGSNNODE(Optional) Administrative state of the SGSN. The value "ALLOW" indicates that the SGSN can handle the PS services normally. The value "UNISTALL" indicates that the SGSN does not permit new PS services to access the network and the ongoing PS services are not affected. The value "DENY" indicates that the SGSN denies all PS services. GBFD-119701SGSN Pool Enumeration Type UNISTALL(uninstall), ALLOW(allow), DENY(deny) UNISTALL, ALLOW, DENY None ALLOW ALLOW BSC None Read & Write Y BSC6900 Services are interrupted until the parameter is set to ALLOW or the cell is configured with a new SGSN. If this SGSN is the last SGSN connecting this cell: 1. When the parameter is set to DENY, the services of all the online subscribers are interrupted and new subscribers cannot access the network.2. When the parameter is set to UNINSTALL, the services of all the online subscribers are not interrupted and new subscribers cannot access the network.
SHAREINCPURATE Share in CPU Rate BSC6900 SET BSCFCPARA(Optional) Usage threshold of the CPU for call access from other CPU. If the usage of the CPU exceeds the threshold, the call access request is discarded. GBFD-111705GSM Flow Control Interval Type 50~95 50~95 per cent None 75 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SHARESN Load Sharing Slot No. BSC6900 ADD ABISLOADSHARE(Mandatory) Slot No. of the load sharing interface board GBFD-111203O&M of BSC Interval Type 0~27 0~27 None None None None None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
SHARINGALLOW Sharing Allow BSC6900 SET BTSSHARING(Optional) Whether to allow sharing GBFD-118701RAN Sharing Enumeration Type NO(NO), YES(YES) NO, YES None NO None BTS None Read & Write Y Cell Less than 5 minutes None
shldflg Shield Flag BSC6900 SET ALMSHLD(Mandatory) Shield flag of the alarm MRFD-210304Faulty Management Enumeration Type unshielded(Unshielded), shielded(Shielded) unshielded, shielded None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SHUTDOWNTRXSTARTTIME Shutdown TRX Start Time[T2] BSC6900 SET BTSBAKPWR(Optional) Delay for which the BTS waits to shut down the TRX after switching from the mains to batteries GBFD-111605Active Backup Power Control Interval Type 0~12 0~12 h None 3 BTS This parameter is valid only when the cell parameter "BAKPWRSAVMETHOD" is set to BYPWR and "SDFALG" in "SET GTRXDEV" is set to ENABLE. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SI2TerSwitch SI 2ter Switch BSC6900 SET OTHSOFTPARA(Optional) Whether the BSC sends a System Information Type 2ter message to a non-dualband cell. When the parameter is set to YES, the cell does not send the System Information Type 2ter message if the cell is not configured with inter-frequency neighboring cells. If the cell is configured with inter-frequency neighboring cells, the cell sends the System Information Type 2ter message. When the parameter is set to NO and "Send System Information 2ter " is set to YES, the cell sends the System Information Type 2ter message. Otherwise, the cell does not send the message. GBFD-111101System Information Sending Enumeration Type NO, YES NO, YES None None YES BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SIGCHANHOEN SDCCH HO Allowed BSC6900 SET GCELLHOBASIC(Optional) Whether to enable a handover between signaling channels GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Enumeration Type NO(No), YES(Yes)NO, YES None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SIGLAST Signal Strength Duration Times BSC6900 ADD AISSCFG(Optional) Number of times that the downlink signal strength exceeds the threshold. GBFD-118201Soft-Synchronized Network Interval Type 1~10 1~10 None 4 None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None.
SIGLKSX Signalling link set index BSC6900 ADD MTP3RT(Mandatory)ADD MTP3LKS(Mandatory)ADD MTP3LNK(Mandatory) To identify an signaling link set uniquely. None None Interval Type 0~182 0~182 None None None BSC6900None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
SIGLKSX Signalling link set index BSC6900 ADD M3RT(Mandatory)ADD M3LKS(Mandatory)ADD M3LNK(Mandatory) To identify an signaling link set index uniquely. None None Interval Type 0~182 0~182 None None None BSC6900None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
SIGLNKID Signaling link ID BSC6900 ADD M3LNK(Mandatory) M3UA link ID of the specified link set. None None Interval Type 0~15 0~15 None None None BSC6900None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
SIGLW Signalling Load Weight BSC6900 ADD NSVLLOCAL(Optional) Signalling local weight over the local NSVL. When this parameter is set to a larger value, the NS is more likely to select this IP point according to the load sharing function of the NSVC link of the IP network if the NS sends a signalling message. GBFD-118603Gb over IP Interval Type 0~255 0~255 None 100 100 NSE None Read & Write Y NSE Services are interrupted until "SIGLW" is not set to 0. The ratio of Gb interface signalling message s sent through NSVLs is affected when this parameter is modified. When this NSVL is the last NSVL of the normal state in the NSE, if "SIGLW" is set to 0, the signalling exchange between the NSE and SGSN is interrupted.
SIGLW Signalling Load Weight BSC6900 ADD NSVLREMOTE(Optional) Signalling local weight over the remote NSVL. When this parameter is set to a larger value, the NS is more likely to select this IP point according to the load sharing function of the NSVC link of the IP network if the NS sends a signalling message. GBFD-118603Gb over IP Interval Type 0~255 0~255 None 100 100 NSE None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SIGNALSP Signal Service PRI BSC6900 SET BSCSRVPRI(Optional) Priority of the signaling service GBFD-118605IP QOS Interval Type 0~7 0~7 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SIGOBS Signal Strength Observation Times BSC6900 ADD AISSCFG(Optional) Number of times that the downlink signal is measured. GBFD-118201Soft-Synchronized Network Interval Type 1~10 1~10 None 5 None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None.
SIGQUAFLTLEN Filter Length for SDCCH Qual BSC6900 SET GCELLHOFITPEN(Optional) Number of measurement reports used for averaging the signal quality of signaling channels. This parameter helps avoid sharp drop of signal levels caused by Raileigh fading and to ensure correct handover decisions. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 1~31 1~31, step:480 for TCH and 470 for SDCCH ms None 2 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SIGSLC Signalling link code BSC6900 ADD MTP3LNK(Mandatory) MTP3 link ID of the specified link set. None None Interval Type 0~15 0~15 None None None MTP3 linkNone Read & Write Not involved Not involved Not involved The parameter cannot be modified.
SIGSTRFLTLEN Filter Length for SDCCH Level BSC6900 SET GCELLHOFITPEN(Optional) Number of measurement reports used for averaging the signal strength of signaling channels. This parameter helps avoid sharp drop of signal levels caused by Raileigh fading and to ensure correct handover decisions. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 1~31 1~31, step:480 for TCH and 470 for SDCCH ms None 2 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SilenceTicksOfResReq Interval Between Resource Request BSC6900 SET BSCPSSOFTPARA(Optional) Minimum interval between the successful TBF establishment and the first initiation of the Packet Timeslot Reconfiguration procedure. GBFD-119303Load Sharing Interval Type 0~65535 0~65535 ms None 3000 BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SinglePassExcludeMsisdn1 Single Pass Exclude Msisdn Number 1 BSC6900 SET BSCBASIC(Optional) Single pass exclude MSISDN number 1. Certain numbers, such as the premium rate number, are not used for the single pass check. The number is stored in character string. GBFD-111203O&M of BSC String Type None 1~32 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SinglePassExcludeMsisdn10 Single Pass Exclude Msisdn Number 10 BSC6900 SET BSCBASIC(Optional) Single pass exclude MSISDN number 10. Certain numbers, such as the premium rate number, are not used for the single pass check. The number is stored in character string. GBFD-111203O&M of BSC String Type None 1~32 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SinglePassExcludeMsisdn11 Single Pass Exclude Msisdn Number 11 BSC6900 SET BSCBASIC(Optional) Single pass exclude MSISDN number 11. Certain numbers, such as the premium rate number, are not used for the single pass check. The number is stored in character string. GBFD-111203O&M of BSC String Type None 1~32 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SinglePassExcludeMsisdn12 Single Pass Exclude Msisdn Number 12 BSC6900 SET BSCBASIC(Optional) Single pass exclude MSISDN number 12. Certain numbers, such as the premium rate number, are not used for the single pass check. The number is stored in character string. GBFD-111203O&M of BSC String Type None 1~32 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SinglePassExcludeMsisdn13 Single Pass Exclude Msisdn Number 13 BSC6900 SET BSCBASIC(Optional) Single pass exclude MSISDN number 13. Certain numbers, such as the premium rate number, are not used for the single pass check. The number is stored in character string. GBFD-111203O&M of BSC String Type None 1~32 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SinglePassExcludeMsisdn14 Single Pass Exclude Msisdn Number 14 BSC6900 SET BSCBASIC(Optional) Single pass exclude MSISDN number 14. Certain numbers, such as the premium rate number, are not used for the single pass check. The number is stored in character string. GBFD-111203O&M of BSC String Type None 1~32 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SinglePassExcludeMsisdn15 Single Pass Exclude Msisdn Number 15 BSC6900 SET BSCBASIC(Optional) Single pass exclude MSISDN number 15. Certain numbers, such as the premium rate number, are not used for the single pass check. The number is stored in character string. GBFD-111203O&M of BSC String Type None 1~32 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SinglePassExcludeMsisdn16 Single Pass Exclude Msisdn Number 16 BSC6900 SET BSCBASIC(Optional) Single pass exclude MSISDN number 16. Certain numbers, such as the premium rate number, are not used for the single pass check. The number is stored in character string. GBFD-111203O&M of BSC String Type None 1~32 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SinglePassExcludeMsisdn17 Single Pass Exclude Msisdn Number 17 BSC6900 SET BSCBASIC(Optional) Single pass exclude MSISDN number 17. Certain numbers, such as the premium rate number, are not used for the single pass check. The number is stored in character string. GBFD-111203O&M of BSC String Type None 1~32 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SinglePassExcludeMsisdn18 Single Pass Exclude Msisdn Number 18 BSC6900 SET BSCBASIC(Optional) Single pass exclude MSISDN number 18. Certain numbers, such as the premium rate number, are not used for the single pass check. The number is stored in character string. GBFD-111203O&M of BSC String Type None 1~32 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SinglePassExcludeMsisdn19 Single Pass Exclude Msisdn Number 19 BSC6900 SET BSCBASIC(Optional) Single pass exclude MSISDN number 19. Certain numbers, such as the premium rate number, are not used for the single pass check. The number is stored in character string. GBFD-111203O&M of BSC String Type None 1~32 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SinglePassExcludeMsisdn2 Single Pass Exclude Msisdn Number 2 BSC6900 SET BSCBASIC(Optional) Single pass exclude MSISDN number 2. Certain numbers, such as the premium rate number, are not used for the single pass check. The number is stored in character string. GBFD-111203O&M of BSC String Type None 1~32 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SinglePassExcludeMsisdn20 Single Pass Exclude Msisdn Number 20 BSC6900 SET BSCBASIC(Optional) Single pass exclude MSISDN number 20. Certain numbers, such as the premium rate number, are not used for the single pass check. The number is stored in character string. GBFD-111203O&M of BSC String Type None 1~32 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SinglePassExcludeMsisdn3 Single Pass Exclude Msisdn Number 3 BSC6900 SET BSCBASIC(Optional) Single pass exclude MSISDN number 3. Certain numbers, such as the premium rate number, are not used for the single pass check. The number is stored in character string. GBFD-111203O&M of BSC String Type None 1~32 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SinglePassExcludeMsisdn4 Single Pass Exclude Msisdn Number 4 BSC6900 SET BSCBASIC(Optional) Single pass exclude MSISDN number 4. Certain numbers, such as the premium rate number, are not used for the single pass check. The number is stored in character string. GBFD-111203O&M of BSC String Type None 1~32 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SinglePassExcludeMsisdn5 Single Pass Exclude Msisdn Number 5 BSC6900 SET BSCBASIC(Optional) Single pass exclude MSISDN number 5. Certain numbers, such as the premium rate number, are not used for the single pass check. The number is stored in character string. GBFD-111203O&M of BSC String Type None 1~32 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SinglePassExcludeMsisdn6 Single Pass Exclude Msisdn Number 6 BSC6900 SET BSCBASIC(Optional) Single pass exclude MSISDN number 6. Certain numbers, such as the premium rate number, are not used for the single pass check. The number is stored in character string. GBFD-111203O&M of BSC String Type None 1~32 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SinglePassExcludeMsisdn7 Single Pass Exclude Msisdn Number 7 BSC6900 SET BSCBASIC(Optional) Single pass exclude MSISDN number 7. Certain numbers, such as the premium rate number, are not used for the single pass check. The number is stored in character string. GBFD-111203O&M of BSC String Type None 1~32 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SinglePassExcludeMsisdn8 Single Pass Exclude Msisdn Number 8 BSC6900 SET BSCBASIC(Optional) Single pass exclude MSISDN number 8. Certain numbers, such as the premium rate number, are not used for the single pass check. The number is stored in character string. GBFD-111203O&M of BSC String Type None 1~32 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SinglePassExcludeMsisdn9 Single Pass Exclude Msisdn Number 9 BSC6900 SET BSCBASIC(Optional) Single pass exclude MSISDN number 9. Certain numbers, such as the premium rate number, are not used for the single pass check. The number is stored in character string. GBFD-111203O&M of BSC String Type None 1~32 characters None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SIPADDR Source IP address BSC6900 PING IP(Mandatory) Source IP address None None IP Address Type None 0.0.0.0~255.255.255.255 None None None Ethernet port None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The source IP address can be: local IP address of the PPP link (PEUa/POUa/POS), local IP address of the MP group ((PEUa/POUa), IP address of the Ethernet port of the local port (FG2a/GOUa), and IP address of the local board.
SIPADDR Source IP address BSC6900 TRC IPADDR(Optional) Source IP address None None IP Address Type None 0.0.0.0~255.255.255.255 None None None None None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
SIPDL UMTS IMS SRB service downlink factor BSC6900 ADD TRMFACTOR(Optional) WCDMA IMS signaling service downlink factor None None Interval Type 0~100 0~100 per cent 15 15 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node that is configured with the factor table. After the successful modification, the parameter takes effect in the following two cases:1. New access subscriber. 2. Bandwidth modification of the existing subscriber
SIPPRIPATH IMS SRB primary path BSC6900 ADD TRMMAP(Optional) IMS SRB primary path None None Enumeration Type CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF None None When the interface type is Iub, transmission type is ATM or dual stack, the parameter is RT_VBR; transimssion type is IP or Hybird IP, the parameter is EF.When the interface type is Iur, transmission type is ATM, the parameter is RT_VBR; transimssion type is IP, the parameter is EF. BSC6900When the value of "ITFT" in "ADD TRMMAP" is set to IUB or IUR or IUPS, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node configured with the TRMMAP. After the successful modification, it is valid in the case of the new access of a subscriber and the bandwidth modification of an existing subscriber.
SIPSECPATH IMS SRB secondary path BSC6900 ADD TRMMAP(Optional) IMS signaling service bearer secondary path None None Enumeration Type CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF, NULL CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF, NULL None None When the interface type is Iub, transmission type is ATM or IP, the parameter is NULL; transimssion type is dual stack, the parameter is EF; transimssion type is Hybird IP, the parameter is LQEF.When the interface type is Iur, transmission type is ATM or IP, the parameter is NULL. BSC6900When the value of "ITFT" in "ADD TRMMAP" is set to IUB or IUR, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node configured with the TRMMAP. After the successful modification, it is valid in the case of the new access of a subscriber and the bandwidth modification of an existing subscriber.
SIPUL UMTS IMS SRB service uplink factor BSC6900 ADD TRMFACTOR(Optional) WCDMA IMS signaling service uplink factor None None Interval Type 0~100 0~100 per cent 15 15 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node that is configured with the factor table. After the successful modification, the parameter takes effect in the following two cases:1. New access subscriber. 2. Bandwidth modification of the existing subscriber
SITES Sites BSC6900 COL LOG(Optional) which sites of log to be collected. GBFD-111203O&M of BSC Interval Type 0~65535 0~65535 None None None RNC None Read & Write Not involved Not involved Not involved None
SITESYNCZONE Site Sync Zone BSC6900 SET BTSAISS(Mandatory) Zone where the BTS synchronizes with other BTSs. Only two BTSs with the same synchronization zone can be synchronized in a synchronization task. GBFD-118201Soft-Synchronized Network Interval Type 0~255 0~255 None 255 None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None.
SLAVEIPADDR Slave Clock Server IP Address BSC6900 SET BTSIPCLKPARA(Mandatory) IP address of the slave clock server. The IP address must be a valid class A, B, or C address, and it cannot be a broadcast address or network address. GBFD-118606Clock over IP IP Address Type None 0.0.0.0~255.255.255.255 None None None BTS The value of this parameter cannot be the same as "Master Clock Server IP Address". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SLAVELOCGRPNO Sub-Location Group No. BSC6900 ADD BTSBINDLOCGRP(Mandatory) No. of the location group under the BTS. The location group No. is unique for each BTS. GBFD-510104Multi-site Cell Interval Type 0~35 0~35 None None None BTS None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
SLPAGECTHD SS and LCS page control threshold BSC6900 SET FCCPUTHD(Optional) CPU usage threshold for paging flow control over supplementary services (SS) and location service (LCS). When the average CPU usage of sliding windows reaches or exceeds the threshold, SS and LCS paging flow control is triggered. This parameter is valid only when "Board Class" is "XPU". WRFD-040100Flow Control Interval Type 30~100 30~100 per cent None 80 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SLPAGERTHD SS and LCS page restore threshold BSC6900 SET FCCPUTHD(Optional) CPU usage threshold for recovery from paging flow control over supplementary services and location service. When the average CPU usage of sliding windows is lower than the threshold, SS and LCS paging flow control is stopped. This parameter is valid only when "Board Class" is "XPU". WRFD-040100Flow Control Interval Type 30~100 30~100 per cent None 70 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SLPTYPE Self Loop Type BSC6900 STR TRANSPERFTST(Mandatory) Self-loop type. The precautions are as follows: 1. If the self-loop type is set to "E1SELFLOOP" and the BTS type is BTS3002C, BTS3001C, or BTS3001CP, the TMU type can be set to only "Active TMU/MMU/IOMU/DOMU". If the BTS type is BTS3006C or BTS3002E, the TMU type cannot be set to "Active/Standby TMU".2. If the self-loop type is set to "IASUSELFLOOP" and the BTS type is BTS3002C, the TMU type can be set to only "Active DOMU". GBFD-111207BTS Test Function Enumeration Type E1SELFLOOP(E1 Self Loopback), IASUSELFLOOP(IASU Self Loopback) E1SELFLOOP, IASUSELFLOOP None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SLSMASK Signalling route mask BSC6900 ADD N7DPC(Optional) Signaling route load sharing. In the value, the number of 1s (represented by n) determines the maximum number (2) of routes for the load sharing. For example, B0000 indicates that up to one route is used for the load sharing, B0001 and B1000 indicate that up to two routes are used for the load sharing. The additional routes are not used for the load sharing. The AND operation between this value and " signaling link mask " in the MTP3LKS is equal to 0. None None Enumeration Type B0000(B0000), B0001(B0001), B0010(B0010), B0011(B0011), B0100(B0100), B0101(B0101), B0110(B0110), B0111(B0111), B1000(B1000), B1001(B1001), B1010(B1010), B1011(B1011), B1100(B1100), B1101(B1101), B1110(B1110), B1111(B1111) B0000, B0001, B0010, B0011, B0100, B0101, B0110, B0111, B1000, B1001, B1010, B1011, B1100, B1101, B1110, B1111 None B0000 B0000 SCCP None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modified parameter takes effect after the BSC is reset.
SLVSERVACTDELAY Slave Service Active Delay BSC6900 SET GBSCREDGRP(Optional) If no handshake message is received from the peer within the delay, the slave service is activated. GBFD-113725BSC Node Redundancy Interval Type 1~600 1~600 s 300 None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SM StartType BSC6900 SET TZ(Mandatory) Type of the start date. "WEEK" indicates that the start date is a weekday. "DATE" indicates that the start date is a month day. "DATEWEEK" indicates the start date is expressed by a combination of weekday and month day. MRFD-210301Configuration Management Enumeration Type DATE(Input with date), WEEK(Input with week), DATEWEEK(Input with date and week) DATE, WEEK, DATEWEEK None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SMOKE_MASK Enable Smoke Alarm Reporting BSC6900 ADD EMU(Optional) Smog alarm switch MRFD-210304Faulty Management Enumeration Type CLOSE(Close), OPEN(Open) CLOSE, OPEN None OPEN None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SMONTH Start month BSC6900 SET TZ(Mandatory) Month in which DST starts MRFD-210301Configuration Management Enumeration Type JAN(January), FEB(February), MAR(March), APR(April), MAY(May), JUN(June), JUL(July), AUG(August), SEP(September), OCT(October), NOV(November), DEC(December) JAN, FEB, MAR, APR, MAY, JUN, JUL, AUG, SEP, OCT, NOV, DEC None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SMPAGECTHD SMS page control threshold BSC6900 SET FCCPUTHD(Optional) CPU usage threshold for paging flow control over the short message service (SMS). When the average CPU usage of sliding windows reaches or exceeds the threshold, SMS paging flow control is triggered. This parameter is valid only when "Board Class" is "XPU". WRFD-040100Flow Control Interval Type 30~100 30~100 per cent None 70 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SMPAGERTHD SMS page restore threshold BSC6900 SET FCCPUTHD(Optional) CPU usage threshold for recovery from paging flow control over the short message service (SMS). When the average CPU usage of smooth windows is lower than the threshold, SMS paging flow control is stopped. This parameter is valid only when "Board Class" is "XPU". WRFD-040100Flow Control Interval Type 30~100 30~100 per cent None 60 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SMWINDOW Filter window BSC6900 SET FCCPUTHD(Optional)SET FCMSGQTHD(Optional) Number of CPU usage samples involved in the calculation of the average CPU usage in the sliding window WRFD-040100Flow Control Interval Type 2~2000 2~2000 None None 10 None The number of CPU usage sampling times is at least twice the size of "Fast judgement window". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SN Slot No. BSC6900 SWP BRD(Mandatory) Number of the slot MRFD-210301Configuration Management Interval Type 0,2,4,6,8,10,12,14,16,18,20,22,24,26 0, 2, 4, 6, 8, 10, 12, 14, 16, 18, 20, 22, 24, 26 None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SN Slot No. BSC6900 STR BKP(Mandatory)CMP BRDAREA(Optional)STR CPUUSAGETST(Mandatory)ULD RSTINFO(Mandatory)ADD BRD(Mandatory)SET CLK(Mandatory)SET XPUPORT(Mandatory)ADD XPUVLAN(Mandatory)SET MPUBIND(Mandatory)SET DPUBRDTYPE(Mandatory)SYN BRDAREA(Optional)CMP TBLDATA(Mandatory)SET MSPCMD(Mandatory)SET MSP(Mandatory)SET BFDPROTOSW(Mandatory)STR FRPORTLOOP(Mandatory)ADD BC(Mandatory)ADD NSVC(Mandatory)ADD NSVLLOCAL(Mandatory)SET PSCELLTODSP(Mandatory)ADD BTSAUTOPLAN(Mandatory)ADD BTSCONNECT(Mandatory) Number of the slot MRFD-210301Configuration Management Interval Type 0~27 0~27 None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SN Slot No. BSC6900 DLD TCFILE(Mandatory) Number of the slot MRFD-210301Configuration Management Interval Type 0~3,8~27 0~3, 8~27 None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SN Slot No. BSC6900 ADD MTP3LNK(Mandatory)ADD SCTPLNK(Mandatory) SPU slot No.. None None Interval Type 0,2,4,8,10,12,14,16,18,20,22,24,26 0, 2, 4, 8, 10, 12, 14, 16, 18, 20, 22, 24, 26 None None None Transmission resource group None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
SN Slot No. BSC6900 ADD ADJNODE(Mandatory) It is valid when the node type is set to UNI_AAL2SWITCH. It is the slot number of the SAAL link of the AAL2 signaling bearing the adjacent node. None None Interval Type 0,2,4,8,10,12,14,16,18,20,22,24,26 0, 2, 4, 8, 10, 12, 14, 16, 18, 20, 22, 24, 26 None None None Adjacent node When the value of "NODET" in "ADD ADJNODE" is set to IUB, and the value of "IsROOTNODE" in "ADD ADJNODE" is set to YES, or the value of "NODET" in "ADD ADJNODE" is set to UNI_AAL2SWITCH, this parameter is valid. Read & Write Not involved Not involved Not involved The parameter cannot be modified.
SN Control slot No. BSC6900 ADD M3LNK(Mandatory) SPU slot No. of controlling the M3UA link. None None Interval Type 0,2,4,8,10,12,14,16,18,20,22,24,26 0, 2, 4, 8, 10, 12, 14, 16, 18, 20, 22, 24, 26 None None None BSC6900None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
SN Slot No BSC6900 SET PHBMAP(Mandatory)ADD ATERE1T1(Mandatory)ADD AE1T1(Mandatory) Slot number None None Interval Type 0~5,8~27 0~5, 8~27 None None None E1/T1 linkNone Read & Write Not involved Not involved Not involved The parameter cannot be modified.
SN Slot No. BSC6900 ADD PBE1T1(Mandatory)BLK AE1T1(Mandatory) Slot No.. GBFD-111203O&M of BSC Interval Type 0~27 0~27 None None None Transmission resource group None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
SN BM Slot No BSC6900 BLK ATERE1T1(Mandatory) It is one key field of identifying the Ater timeslot and indicates the timeslot No. of the Ater interface timeslot. None None Interval Type 0~5,8~27 0~5, 8~27 None None None E1/T1 linkNone Read & Write N (No impact on the UE in idle mode) Not involved Not involved 1. The block of Ater interface must be configured. 2. If the BSC is configured to the integrated BMTC or A over IP is configured, the configuration does not support the operation. 3. If the block operation is applicable to only the ATERTS of the BM subrack. You are not allowed to perform the block operation from the primary BM subrack to the secondary BM subrack.
sn Slot No. BSC6900 EXP ALMLOG(Optional)STAALMLOG(Optional) Number of the slot where the alarm is generated MRFD-210304Faulty Management Interval Type 0~27 0~27 None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SN Slot No. BSC6900 ADD OBJALMSHLD(Optional) Number of the slot where the alarm is generated MRFD-210304Faulty Management Interval Type 0~27 0~27 None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SN Slot No. BSC6900 SET E1T1LOP(Mandatory)LOP E1T1(Mandatory)STR E1T1TST(Mandatory)SET OPTLOP(Mandatory)PING IP(Mandatory)TRC IPADDR(Mandatory)SET QUEUEMAP(Mandatory)SET E1T1(Mandatory)ADD TSCROSS(Mandatory)ADD DEVIP(Mandatory)ADD IPRT(Mandatory)SET OPT(Mandatory)SET COPTLNK(Mandatory)SET ETHPORT(Mandatory)ADD PPPLNK(Mandatory)ADD MPGRP(Mandatory)ADD MPLNK(Mandatory)ADD ETHIP(Mandatory)ADD IPLOGICPORT(Mandatory)ADD ICMPGUARD(Mandatory)STR IPCHK(Mandatory)ADD VLANID(Mandatory)CHK E1T1CRS(Mandatory)ADD IPPATHBIND(Mandatory)ADD IPRTBIND(Mandatory)ADD ETHMD(Mandatory)ADD ETHMA(Mandatory)ADD ETHMEP(Mandatory)PING MAC(Mandatory)STR ETHOAMLOOPTST(Mandatory)TRC MAC(Mandatory)ADD ETHTRK(Mandatory)ADD ETHTRKLNK(Mandatory)ADD ETHTRKIP(Mandatory)STR ETHMIRRORPORT(Mandatory)BLK BC(Mandatory)SET BTSIP(Mandatory) Indicates the slot number for running this command None None Interval Type 0~5,8~27 0~5, 8~27 None None None BSC6900None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
SN Main Board Logic slot No. BSC6900 SWP ETHPORT(Mandatory)ADD ETHREDPORT(Mandatory) Slot number for running this command None None Interval Type 0,2,4,8,10,12,14,16,18,20,22,24,26 0, 2, 4, 8, 10, 12, 14, 16, 18, 20, 22, 24, 26 None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SN Serial Number BSC6900 SET GCELLRACHCCLEV(Optional) Delivery serial number of the RET antenna MRFD-210602Remote Electrical Tilt String Type None 1~16 characters None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SN Slot No. BSC6900 ADD GCBSADDR(Mandatory)SET TCPLYVOICE(Mandatory)SET TCPARA(Mandatory) Number of the slot. The subrack number and slot number uniquely identify a board. MRFD-210301Configuration Management Interval Type 0~27 0~27 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SN Slot No. BSC6900 ADD GIURGCONN(Mandatory) Slot No. of the subsystem where the Iur-g common connection is established MRFD-211402MBSC Load Balancing Interval Type 0~27 {0~27} None None None BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SN Slot No. BSC6900 SWP BTSRING(Optional)SWP BTSOMLLINK(Optional)ADD TRXBIND2PHYBRD(Mandatory)SET BTSFMUABP(Mandatory)SET BTSNFCBBP(Mandatory)SET BTSPMUBP(Mandatory)SET BTSAPMUBP(Mandatory)SET BTSDATUBP(Mandatory)SET BTSDEMUBP(Mandatory)SET BTSDFCUBP(Mandatory)SET BTSDHEUBP(Mandatory)SET BTSDOMUBP(Mandatory)SET BTSDPMUBP(Mandatory)SET BTSDTMUBP(Mandatory)SET BTSDGPSBP(Mandatory)SET BTSDDPUBP(Mandatory)SET BTSUSCUBP(Mandatory)SET BTSRXUBP(Mandatory)ADD BTSRXU2LOCGRP(Mandatory)ADD BTSBINDLOCGRP(Mandatory)ADD BTSANTFEEDERBRD(Mandatory)ADD BTSBRD(Mandatory)ADD BTSRXUBRD(Optional)ADD BTSTRXBRD(Mandatory)SET BTSENVALMPORT(Mandatory)ADD BTSOBJALMSHLD(Mandatory)SET BTSANTFEEDERCONNECT(Mandatory)LOD RETANTCFG(Mandatory)SET BTSANTANGLE(Mandatory)SET BTSCLKPARA(Mandatory)SET BTSCAVFRQ(Mandatory)SET BTSPMUDEF(Mandatory)SET BTSTMA(Mandatory)SET RETANTENB(Mandatory)STR BTSBATTTST(Mandatory)STR RETANTSCAN(Mandatory)STR TRANSPERFTST(Optional)SWP BTSBRD(Mandatory)SET BTSENVALM(Mandatory)CHG BTSPTUSHKTM(Mand Number of the slot where the BTS board is located GBFD-111202O&M of BTS Interval Type 0~23 0~23 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SN Slot No. BSC6900 ADD BTSBFD(Optional)ADD BTSIPRTBIND(Optional) Number of the slot where the BTS board is located GBFD-118609IP Fault Detection Based on BFD Interval Type 0~23 0~23 None 6 None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SN Slot No. BSC6900 ADD NSE(Mandatory) Slot number of the XPU bound to the NSE. MRFD-210301Configuration Management Interval Type 0,2,4,8,10,12,14,16,18,20,22,24,26 0, 2, 4, 8, 10, 12, 14, 16, 18, 20, 22, 24, 26 None None None Board None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
SN Slot No. BSC6900 ADD PBSL(Mandatory) Slot No. of board to which Pb signaling link belongs. GBFD-111203O&M of BSC Interval Type 0~27 0~27 None None None Transmission resource group None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
SN Port Slot No. BSC6900 ADD BTSSFPMODE(Optional)SET BTSFORBIDTS(Optional)SET BTSOMLTS(Optional)ADD BTSTOPCONFIG(Optional)SET BTSETHPORT(Optional)ADD BTSPPPLNK(Optional)ADD BTSMPLNK(Optional)ADD BTSETHMA(Optional)ADD BTSETHLCMEP(Optional) Number of the slot where the port is located GBFD-111202O&M of BTS Interval Type 0~23 0~23 None None None BTS None Read & Write Y BTS Less than 5 minutes None
SNDMD Send Mode BSC6900 SET GTRXDEV(Optional) RF transmission mode of the TRX MRFD-210301Configuration Management Enumeration Type NOCOMB(No Combination), PBT(PBT), WBANDCOMB(Wideband Combination), DIVERSITY(Transmit Diversity), DDIVERSITY(Dynamic Transmit Diversity), DPBT(DPBT), DTIC(Transmit Independency or Combination), NONE(none) NOCOMB, PBT, WBANDCOMB, DIVERSITY, DDIVERSITY, DPBT, DTIC, NONE None None None TRX None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SndRcvMode DRRU Snd Rcv Mode BSC6900 SET BTSRXUBP(Optional) Sending and receiving mode of the DRRU board GBFD-111202O&M of BTS Enumeration Type SGL_ANTENNA(Single Feeder[1TX + 1RX]), SGLDOUBLE_ANTENNA(Single Feeder[1TX + 2RX]), DOUBLE_ANTENNA(Double Feeder[2TX + 2RX]), DOUBLEFOUR_ANTENNA(Double Feeder[2TX + 4RX]), DOUBLESINGLE_ANTENNA(Double Feeder[1TX + 1RX]), DOUBLEDOUBLE_ANTENNA(Double Feeder[1TX + 2RX]) SGL_ANTENNA, SGLDOUBLE_ANTENNA, DOUBLE_ANTENNA, DOUBLEFOUR_ANTENNA, DOUBLESINGLE_ANTENNA, DOUBLEDOUBLE_ANTENNA None DOUBLE_ANTENNA None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SndRcvMode1 DRFU Snd Rcv Mode BSC6900 SET BTSRXUBP(Optional) Sending and receiving mode of the DRFU board GBFD-111202O&M of BTS Enumeration Type SGL_ANTENNA(Single Feeder[1TX + 1RX]), SGLDOUBLE_ANTENNA(Single Feeder[1TX + 2RX]), DOUBLE_ANTENNA(Double Feeder[2TX + 2RX]), DOUBLEFOUR_ANTENNA(Double Feeder[2TX + 4RX]), DOUBLESINGLE_ANTENNA(Double Feeder[1TX + 1RX]), DOUBLEDOUBLE_ANTENNA(Double Feeder[1TX + 2RX]) SGL_ANTENNA, SGLDOUBLE_ANTENNA, DOUBLE_ANTENNA, DOUBLEFOUR_ANTENNA, DOUBLESINGLE_ANTENNA, DOUBLEDOUBLE_ANTENNA None DOUBLE_ANTENNA None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SndRcvMode2 MRRU/GRRU Snd Rcv Mode BSC6900 SET BTSRXUBP(Optional) Sending and receiving mode of the MRRU/GRRU board GBFD-111202O&M of BTS Enumeration Type SGL_ANTENNA(Single Feeder[1TX + 1RX]), SGLDOUBLE_ANTENNA(Single Feeder[1TX + 2RX]), DOUBLE_ANTENNA(Double Feeder[2TX + 2RX]), DOUBLEFOUR_ANTENNA(Double Feeder[2TX + 4RX]), DOUBLESINGLE_ANTENNA(Double Feeder[1TX + 1RX]), DOUBLEDOUBLE_ANTENNA(Double Feeder[1TX + 2RX]) SGL_ANTENNA, SGLDOUBLE_ANTENNA, DOUBLE_ANTENNA, DOUBLEFOUR_ANTENNA, DOUBLESINGLE_ANTENNA, DOUBLEDOUBLE_ANTENNA None DOUBLE_ANTENNA None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SndRcvMode3 MRFU/GRFU Snd Rcv Mode BSC6900 SET BTSRXUBP(Optional) Sending and receiving mode of the MRFU/GRFU board GBFD-111202O&M of BTS Enumeration Type SGL_ANTENNA(Single Feeder[1TX + 1RX]), SGLDOUBLE_ANTENNA(Single Feeder[1TX + 2RX]), DOUBLE_ANTENNA(Double Feeder[2TX + 2RX]), DOUBLEFOUR_ANTENNA(Double Feeder[2TX + 4RX]), DOUBLESINGLE_ANTENNA(Double Feeder[1TX + 1RX]), DOUBLEDOUBLE_ANTENNA(Double Feeder[1TX + 2RX]) SGL_ANTENNA, SGLDOUBLE_ANTENNA, DOUBLE_ANTENNA, DOUBLEFOUR_ANTENNA, DOUBLESINGLE_ANTENNA, DOUBLEDOUBLE_ANTENNA None DOUBLE_ANTENNA None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SndRcvMode4 BTS3900E Snd Rcv Mode BSC6900 SET BTSRXUBP(Optional) Sending and receiving mode of the BTS3900E board GBFD-111202O&M of BTS Enumeration Type SGL_ANTENNA(Single Feeder[1TX + 1RX]), DOUBLESINGLE_ANTENNA(Double Feeder[1TX + 1RX]), DOUBLEDOUBLE_ANTENNA(Double Feeder[1TX + 2RX]) SGL_ANTENNA, DOUBLESINGLE_ANTENNA, DOUBLEDOUBLE_ANTENNA None SGL_ANTENNANone BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SP Sync Period[min] BSC6900 SET SNTPCLTPARA(Mandatory) Synchronization period of the SNTP client service GBFD-111203O&M of BSC Interval Type 1~60 1~60 min None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SPACE Log File Size BSC6900 SET LOGCFG(Optional) Log File Size MRFD-210304Faulty Management Interval Type 1~30 {1~30} None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SPC OSP code[Whole Number] BSC6900 ADD OPC(Optional) As a whole number, the OSP code can be expressed by a decimal digit or a hexadecimal digit. If the OSP code is expressed by a hexadecimal digit, H' is added before the number. None None Interval Type 1~16777215 1~16383(BIT14), 1~65535(BIT16), 1~16777215(BIT24) None None None SCCP When the value of "SPDF" is set to WNF, this parameter is valid. Read & Write Y BSC6900 The services are interrupted until the signaling point is available. None
SPCBITS OSP code bits BSC6900 ADD OPC(Mandatory) OSP code bits.None None Enumeration Type BIT14(BIT14), BIT16(BIT16), BIT24(BIT24) BIT14, BIT16, BIT24 None None None SCCP This parameter depends on network planning. Read & Write Y BSC6900 The services are interrupted until the signaling point is available. None
SPCDNF OSP code[Divided Number] BSC6900 ADD OPC(Optional) Divided OSP code.Input format is 8-8-8 None None String Type None 1~11 characters None None None SCCP When the value of "SPDF" is set to DNF, this parameter is valid. Read & Write Not involved Not involved Not involved The parameter cannot be modified.
SPCIC Start PCIC BSC6900 ADD PBE1T1(Mandatory) Start CIC of the E1/T1 of the Pb interface. GBFD-111203O&M of BSC Interval Type 0~65535 0~65535 None None None PBE1T1 None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SPDF Signal point data format BSC6900 ADD OPC(Optional)ADD N7DPC(Optional) Data format of the specified signaling point. None None Enumeration Type WNF(Whole Number Format), DNF(Divided Number Format) WNF, DNF None WNF WNF SCCP When the value of "SPDF" in "ADD N7DPC" is set to WNF, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SPECACC Special Access Control Class BSC6900 SET GCELLCCBASIC(Optional) This parameter is used for load control. It determines whether the users of special access class are allowed to access the network. Value 1 indicates that access is not allowed. Value 0 indicates that access is allowed. GBFD-111003Radio Common Channel Management Bit Field Type L11_FORBID, L12_FORBID, L13_FORBID, L14_FORBID, L15_FORBID L11_FORBID, L12_FORBID, L13_FORBID, L14_FORBID, L15_FORBID None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SPECIALSWITCH Special Alarm Switch BSC6900 SET BTSFMUABP(Optional) The value of this parameter consists of seven bits. Each bit determines whether to enable the one-way Boolean alarm. "0" indicates that the one-way Boolean alarm is enabled, and "1" indicates that the one-way Boolean alarm is disabled.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. MRFD-210304Faulty Management Bit Field Type ET_DISABLE0, ET_DISABLE1, SMDISABLE, WIDISABLE, GMDISABLE, ARRESTER1, ARRESTER2 ET_DISABLE0, ET_DISABLE1, SMDISABLE, WIDISABLE, GMDISABLE, ARRESTER1, ARRESTER2 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SPECIALSWITCHERLEVEL Special Alarm Valid Level Configuration BSC6900 SET BTSFMUABP(Optional) The value of this parameter consists of five bits. Each bit determines whether the one-way Boolean alarm is triggered by low level or high level. "0" indicates that the alarm is triggered by high level, and "1" indicates that the alarm is triggered by low level.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. MRFD-210304Faulty Management Bit Field Type SMDISABLE, WIDISABLE, GMDISABLE, ARRESTER1, ARRESTER2 SMDISABLE, WIDISABLE, GMDISABLE, ARRESTER1, ARRESTER2 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SpeechVerInAssCmp Speech VER Send Flag in ASS CMP BSC6900 SET MSGSOFTPARA(Optional) Whether to contain the information element of Speech_Ver in the Assignment Complete message GBFD-111804A Interface Protocol Process Enumeration Type NO(No), YES(Yes)NO, YES None YES YES MSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter should be set on the basis of the negotiation with the MSC at the peer end so that the MSC can process the assignment complete message properly. In the assignment request, if the speech/data indicator in the channel type is data, the assignment complete message does not carry SPEECH_VER regardless of the setting of this parameter.
SpeechVerinHoPerform Speech VER Send Flag in HO Perform BSC6900 SET MSGSOFTPARA(Optional) Whether to contain the information element of Speech_Ver in the Handover Perform message GBFD-111804A Interface Protocol Process Enumeration Type NO(No), YES(Yes)NO, YES None YES YES MSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter should be set on the basis of the negotiation with the MSC at the peer end so that the MSC can process the Handover Perform message properly. For SDCCH handovers, the Handover Perform message does not carry speech_ver even if this parameter is set to Yes.
SpeechVerInHoReqAck SpeechVerSend Flag in HO REQ ACK BSC6900 SET MSGSOFTPARA(Optional) Whether to contain the information element of Speech_Ver in the HO_REQ_ACK message GBFD-111804A Interface Protocol Process Enumeration Type NO(No), YES(Yes)NO, YES None YES YES MSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter should be set on the basis of the negotiation with the MSC at the peer end so that the MSC can process the HO REQ ACK message properly.
SpeechVerInHoRqd HO_RQD Speech VER BSC6900 SET MSGSOFTPARA(Optional) Whether to contain the information element of Speech Ver in the HO_RQD message GBFD-111804A Interface Protocol Process Enumeration Type NO(No), YES(Yes)NO, YES None NO NO MSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter should be set on the basis of the negotiation with the MSC at the peer end.
SPEECHVERMODE1 Speech Version Mode 1 BSC6900 SET BTSCHNFALLBACK(Mandatory) Speech version mode that the BTS uses for the VGCS call number in the timeslot in the TRX in fallback mode GBFD-510309Group Call Reliability Enhancing Enumeration Type PSMODE(Protocol Standard Mode), VGCSMODE(VGCS Mode) PSMODE, VGCSMODE None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter is supported only by the following types of BTSs: BTS3012, BTS3006C, BTS3012AE, BTS3012 II, and BTS3002E.
SPEECHVERMODE2 Speech Version Mode 2 BSC6900 SET BTSCHNFALLBACK(Mandatory) Speech version mode that the BTS uses for the VGCS call number in the timeslot in the TRX in fallback mode GBFD-510309Group Call Reliability Enhancing Enumeration Type PSMODE(Protocol Standard Mode), VGCSMODE(VGCS Mode) PSMODE, VGCSMODE None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter is supported only by the following types of BTSs: BTS3012, BTS3006C, BTS3012AE, BTS3012 II, and BTS3002E.
SPEECHVERSION Speech Version BSC6900 SET BTSCHNFALLBACK(Mandatory) Speech version configured on the TRX timeslot when the BTS works in fallback mode. When "CHNTYPE" of the TRX timeslot is set to "FULLTCH", value 0 of this parameter indicates FR and value 1 indicates EFR; when "CHNTYPE" of the TRX timeslot is set to "HALFRCH", this parameter is invalid. GBFD-510309Group Call Reliability Enhancing Enumeration Type FR(FR), EFR(EFR)FR, EFR None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter is supported only by the following types of BTSs: BTS3012, BTS3006C, BTS3012AE, BTS3012 II, and BTS3002E.
SPEEDPUNISH Penalty on MS Fast Moving HO BSC6900 SET GCELLHOAD(Optional) Level value of the penalty that is performed on the neighboring cells of the cell where a fast-moving MS is located. The neighboring cells must be located at the Macro, Micro, or Pico layer other than the Umbrella layer. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 0~63 0~63 dB None 30 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SPEEDPUNISHT Penalty Time on Fast Moving HO BSC6900 SET GCELLHOAD(Optional) Period in which penalty is performed on the neighboring cells of the cell where a fast-moving MS is located. The neighboring cells must be located at the Macro, Micro, or Pico layer but not the Umbrella layer. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 0~255 0~255 s None 40 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SPGCCCCHSUP Support SPLIT_PG_CYCLE on CCCH BSC6900 SET GCELLPSBASE(Optional) Whether to support SPLIT_PG_CYCLE on CCCH. The parameter SPLIT_PG_CYCLE is used to define the DRX period. You can specify whether the paging group based on SPLIT_PG_CYCLE is supported on CCCH for the BTS and the MS. Yes: the paging group based on SPLIT_PG_CYCLE is supported on CCCH. No: the paging group based on SPLIT_PG_CYCLE is not supported on CCCH. GBFD-114802Discontinuous Reception (DRX) Enumeration Type NO(NO), YES(YES) NO, YES None None NO Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SpprtCB Support Cell Broadcast BSC6900 ADD GCNOPERATOR(Optional) Whether to enable the cell broadcast function on the BSC GBFD-113601Short Message Service Cell Broadcast (TS23) Enumeration Type NOTSPPRTBC(NotSupport CB), SPPRTSTANDARD(SupportStandard CB), SPPRTSIMPLE(SupportSimple CB) NOTSPPRTBC, SPPRTSTANDARD, SPPRTSIMPLE None NOTSPPRTBCNOTSPPRTBC BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SPTCOMMMEAS Allow Common Measurement at Iur-g BSC6900 ADD GNRNC(Optional) Whether to support the common bidirectional measurement procedure on the Iur-g interface. MRFD-211402MBSC Load Balancing Enumeration Type NO(No Support), YES(Support) NO, YES None NO None BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SPTINFOEXCHG Allow Info Exchange at Iur-g BSC6900 ADD GNRNC(Optional) Whether to support the bidirectional information exchange procedure on the Iur-g interface. MRFD-211402MBSC Load Balancing Enumeration Type NO(No Support), YES(Support) NO, YES None NO None BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SPTINTERRATINBSCPSHO Support In Inter-RAT Inter-cell PS Handover BSC6900 SET GCELLGPRS(Optional) Whether to support In Inter-RAT Inter-cell PS Handover. The MS in the UMTS cell can be handed over to the BSC local cell through PS handover algorithm. GBFD-119502PS Handover Enumeration Type UNSUPPORT(Not Support), SUPPORT(Support) UNSUPPORT, SUPPORT None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SPTINTERRATOUTBSCPSHO Support Out Inter-RAT Inter-Cell PS Handover BSC6900 SET GCELLGPRS(Optional) Whether support Out Inter-RAT Inter-Cell PS Handover. The MS in the BSC local cell can be handed over to the UMTS cell through PS handover algorithm GBFD-119502PS Handover Enumeration Type UNSUPPORT(Not Support), SUPPORT(Support) UNSUPPORT, SUPPORT None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SPTNACCResGuarantee Support NACC Resource Guarantee BSC6900 SET BSCPSSOFTPARA(Optional) Whether the function of Network Assisted Cell Change (NACC) resource guarantee is allowed. In NC2 or NACC cell reselection, if this parameter is set to YES, dynamic channels are requested in the target cell. GBFD-116301Network Assisted Cell Change (NACC) Enumeration Type NO(NO), YES(YES) NO, YES None None NO BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SptPbLapdCheck Support Pb Lapd Check BSC6900 SET OTHSOFTPARA(Optional) Whether to enable the layer 3 check mechanism on the LAPD links. If the PCU_BSC_LAPD_CHECK_ACK message cannot be received on one Pb link, the Pb link is in single pass mode. Send another two PCU_BSC_LAPD_CHECK_ACK messages. If the PCU_BSC_LAPD_CHECK_ACK message is still not received on the Pb link, set the Pb link to fault state and report the ONE PBSL Link. GBFD-114101GPRS Enumeration Type NO, YES NO, YES None None NO BSC6900This parameter is valid only when "TYPE" in "SET BSCPCUTYPE" is set to OUTER. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SptPbResCheck Support Pb Resource Check BSC6900 SET OTHSOFTPARA(Optional) Whether to enable the enhanced resource check on the Pb interface.The introduction of enhanced resource check is to improve the efficiency of resource checking and define the dependencies of resource status.The external PCU initiates the enhanced resource check. The resources to be checked, consisting of the cell resources, channel resources, and PCIC resources, are provided in list form in the check message, thus reducing the number of messages on the Pb interface and improving the efficiency of checking.The external PCU sends the check message to the BSC. The BSC divides the check message into three independent check messages, each containing one type of resource to be checked, and sends the check message to the corresponding module for resource checking. GBFD-114101GPRS Enumeration Type NO, YES NO, YES None None NO BSC6900This parameter is valid only when "TYPE" in "SET BSCPCUTYPE" is set to OUTER. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SptPbSglPassCheck Support Pb Single Pass Check BSC6900 SET OTHSOFTPARA(Optional) Whether to enable the single pass check function on the Pb links between the BSC and the external PCU. When the Pb link is in single pass mode, a corresponding alarm is reported to the maintenance terminal, and the Pb link is set to broken link state or the priority of the Pb link is lowered. GBFD-114101GPRS Enumeration Type NO, YES NO, YES None None NO BSC6900This parameter is valid only when "TYPE" in "SET BSCPCUTYPE" is set to OUTER. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SptPCICCheck Support PCIC Check BSC6900 SET OTHSOFTPARA(Optional) Whether to enable the PCIC check function on the Pb links between the BSC and the external PCU. When the configuration of the PCIC of the BSC is inconsistent with that of the external PCU, a corresponding alarm is reported to the maintenance terminal, the Pb interface circuit with inconsistent configurations at two ends are blocked, and the priority of the Pb link is lowered. GBFD-114101GPRS Enumeration Type NO, YES NO, YES None None NO BSC6900This parameter is valid only when "TYPE" in "SET BSCPCUTYPE" is set to OUTER. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SptRanSharing Support RAN Sharing BSC6900 SET BSCBASIC(Optional) Whether to support RAN Sharing GBFD-118701RAN Sharing Enumeration Type NO(No), YES(Yes)NO, YES None None NO BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SPTREDUCELATENCY Support Reduced Latency Capability BSC6900 SET GCELLGPRS(Optional) Cell supports reduced latency capability. This parameter is used to reduce the latency during the transmission, thus improving the user experience for conversational services. GBFD-510805Latency Reduction Enumeration Type UNSUPPORT(Not Support), SUPPORT(Support) UNSUPPORT, SUPPORT None None None Cell This parameter is valid only when "EDGE" is set to Support. Read & Write Y Cell Less than 5 minutes None
SPTSHARING RanSharing Support BSC6900 SET BTSRXUBP(Optional) Whether to support RanSharing GBFD-118701RAN Sharing Enumeration Type NO(NO), YES(YES) NO, YES None NO None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SPTSTATEFWL Support State Firewall BSC6900 SET FTPSCLT(Optional) Whether the FTP client supports the state firewall GBFD-111203O&M of BSC Enumeration Type YES(Support), NO(Not Support) YES, NO None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SPUSHAREINOFFSETTHD Offset of current CPU load and target CPU load BSC6900 SET FCCPUTHD(Optional) Difference between CPU usage of the current and target SPUs. If the difference between CPU usage of the current and target SPUs is greater than the value of this parameter, load sharing is triggered between the current and target SPUs. This parameter is valid only when "Board Class" is "XPU". WRFD-040100Flow Control Interval Type 1~100 1~100 per cent None 5 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SPUSHAREOUTTHD Current SPUa CPU share out threshold BSC6900 SET FCCPUTHD(Optional) Load sharing threshold of the current SPU. When the CPU usage of an SPU exceeds the threshold, load sharing is configurable. This parameter is valid only when "Board Class" is "XPU". WRFD-040100Flow Control Interval Type 1~100 1~100 per cent None 50 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SPX OSP index BSC6900 ADD OPC(Mandatory)ADD N7DPC(Mandatory)ADD M3LE(Mandatory) To identify an OSP uniquely. None None Interval Type 0~4 0~4 None None None SCCP None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
SRANMODE Is support SRAN mode BSC6900 ADD BTS(Mandatory) Whether to enable the BTS to identify an object in the BTS in normalized mode, for example, to identify a board by the slot No., subrack No., and cabinet No. and to identify a transmission port by the port No. in a board GBFD-111202O&M of BTS Enumeration Type SUPPORT(Support), NOT_SUPPORT(Not Support) SUPPORT, NOT_SUPPORT None None None BTS None Read & Write Y BTS Less than 5 minutes None
SRANMODE Is support SRAN mode BSC6900 ADD BTSCABINET(Optional) Whether to support the SRAN mode that is used to locate BTS objects, for example, locating a board by the cabinet No., subrack No., and slot No., and locating a transmission port by the inter-board number. GBFD-111202O&M of BTS Enumeration Type SUPPORT~1||(SRAN)$$(Support SRAN)** NOT_SUPPORT(Support SRAN)** NOT_SUPPORT~0||()$$(Not Support) SUPPORT, NOT_SUPPORT None NOT_SUPPORT None BTS None Read & Write Y BTS Less than 5 minutes None
SRBDL UMTS SRB service downlink factor BSC6900 ADD TRMFACTOR(Optional) WCDMA signaling service downlink factor None None Interval Type 0~100 0~100 per cent 15 15 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node that is configured with the factor table. After the successful modification, the parameter takes effect in the following two cases:1. New access subscriber. 2. Bandwidth modification of the existing subscriber
SRBPRIPATH SRB primary path BSC6900 ADD TRMMAP(Optional) Signaling service bearer primary path None None Enumeration Type CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF None None When the interface type is Iub, transmission type is ATM or dual stack, the parameter is RT_VBR; transimssion type is IP or Hybird IP, the parameter is EF.When the interface type is Iur, transmission type is ATM, the parameter is RT_VBR; transimssion type is IP, the parameter is EF. BSC6900When the value of "ITFT" in "ADD TRMMAP" is set to IUB or IUR, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node configured with the TRMMAP. After the successful modification, it is valid in the case of the new access of a subscriber and the bandwidth modification of an existing subscriber.
SRBSECPATH SRB secondary path BSC6900 ADD TRMMAP(Optional) Signaling service bearer secondary path None None Enumeration Type CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF, NULL CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF, NULL None None When the interface type is Iub, transmission type is ATM or IP, the parameter is NOCONFIG; transimssion type is dual stack, the parameter is EF; transimssion type is Hybird IP, the parameter is LQEF.When the interface type is Iur, transmission type is ATM or IP, the parameter is NOCONFIG. BSC6900When the value of "ITFT" in "ADD TRMMAP" is set to IUB or IUR, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node configured with the TRMMAP. After the successful modification, it is valid in the case of the new access of a subscriber and the bandwidth modification of an existing subscriber.
SRBUL UMTS SRB service uplink factor BSC6900 ADD TRMFACTOR(Optional) WCDMA signaling service uplink factor None None Interval Type 0~100 0~100 per cent 15 15 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node that is configured with the factor table. After the successful modification, the parameter takes effect in the following two cases:1. New access subscriber. 2. Bandwidth modification of the existing subscriber
SRC2GNCELLID Source Cell Index BSC6900 ADD G2GNCELL(Mandatory)ADD GIBCAPNCGRP(Mandatory) A cell Index must be unique in one BSC. It is used to uniquely identify a cell. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 0~2047 0~2047 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SRC2GNCELLNAME Source Cell Name BSC6900 ADD G2GNCELL(Mandatory)ADD GIBCAPNCGRP(Mandatory) Name of a cell.MRFD-210301Configuration Management String Type None 1~64 characters None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SRC3GNCELLID Source Cell Index BSC6900 ADD G3GNCELL(Mandatory) A source cell index must be unique in one BSC. It is used to uniquely identify a source cell. The value of this parameter ranges from 0 to 2047. MRFD-210301Configuration Management Interval Type 0~2047 0~2047 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SRC3GNCELLNAME Source Cell Name BSC6900 ADD G3GNCELL(Mandatory) Name of a source cell. MRFD-210301Configuration Management String Type None 1~64 characters None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SRCCI Source Cell CI BSC6900 ADD G2GNCELL(Mandatory) Source cell ID. MRFD-210301Configuration Management Interval Type 0~65535 0~65535 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SRCF Source File Name BSC6900 RUN BATCHFILE(Mandatory) The batch file to be executed: The content of the batch file consists of service commands to be executed in batches. The source file is located in the FTP subdirectory of the OMU installation directory, and you should not add the path when entering the name. The characters (@, #, !, %, ^, &, *, /, ., [, ], \, :, ?, ', ", <, >, and |) cannot appear in the file name. GBFD-111203O&M of BSC String Type None 1~100 characters None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SRCGRD Clock source priority BSC6900 ADD CLKSRC(Mandatory)SET CLKMODE(Mandatory) Priority of the clock source. MRFD-210502BSC/RNC Clock Interval Type 1~4 1~4 None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved Clock sources and priorities are in one-to-one mapping.
SRCHOCTRLSWITCH Current HO CTRL Algorithm in Source Cell BSC6900 ADD G2GNCELL(Optional) Whether the existing handover algorithm of the source cell to use HO Algorithm I or HO Algorithm II. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Enumeration Type HOALGORITHM1(Handover algorithm I), HOALGORITHM2(Handover algorithm II) HOALGORITHM1, HOALGORITHM2 None None None Cell The value of this parameter must be the same as that of "HOCTRLSWITCH" in "SET GCELLHOBASIC". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SRCIP Source IP address BSC6900 ADD BTSBFD(Mandatory) Source IP address of BFD Session. GBFD-118609IP Fault Detection Based on BFD IP Address Type None 0.0.0.0~255.255.255.255 None None None Current BFD session None Read & Write Not involved Not involved Not involved None
SRCLAC Source Cell LAC BSC6900 ADD G2GNCELL(Mandatory) Local area code (LAC) of the source cell. MRFD-210301Configuration Management Interval Type 1~65533,65535 1~65533, 65535 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SRCMCC Source Cell MCC BSC6900 ADD G2GNCELL(Mandatory) Mobile country code (MCC) of the source cell. MRFD-210301Configuration Management String Type None 1~3 characters None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SRCMEPID MEP ID BSC6900 PING MAC(Mandatory)TRC MAC(Mandatory) Identifies a maintenance point in the maintenance group None None Interval Type 1~400 1~400 None None None Ethernet port None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
SRCMNC Source Cell MNC BSC6900 ADD G2GNCELL(Mandatory) Mobile network code (MNC) of the source cell. MRFD-210301Configuration Management String Type None 1~3 characters None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SRCPORTNO Source port No. BSC6900 ADD TSCROSS(Mandatory) Source of timeslot cross None None Interval Type 0~335 0~335 None None None E1/T1 port None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
SRCT Clock source type BSC6900 ADD CLKSRC(Mandatory) Type of the clock source. MRFD-210502BSC/RNC Clock Enumeration Type BITS1-2MHZ(2MHZ Building Integrated Timing Supply system 1), BITS2-2MHZ(2MHZ Building Integrated Timing Supply system 2), BITS1-2MBPS(2MBPS Building Integrated Timing Supply system 1), BITS2-2MBPS(2MBPS Building Integrated Timing Supply system 2), 8KHZ(8KHZ), GPS(Globe Positioning System), LINE1_8KHZ(8KHZ line1), LINE2_8KHZ(8KHZ line2), BITS1-T1BPS(T1BPS Building Integrated Timing Supply system 1), BITS2-T1BPS(T1BPS Building Integrated Timing Supply system 2) BITS1-2MHZ, BITS2-2MHZ, BITS1-2MBPS, BITS2-2MBPS, GPS, 8KHZ, LINE1_8KHZ, LINE2_8KHZ, BITS1-T1BPS, BITS2-T1BPS None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved Clock sources and priorities are in one-to-one mapping. Each backplane board 8K clock has only one clock source.
SRCTSMASK Source timeslot mask BSC6900 ADD TSCROSS(Mandatory) Source timeslot mask None None Bit Field Type TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10, TS11, TS12, TS13, TS14, TS15, TS16, TS17, TS18, TS19, TS20, TS21, TS22, TS23, TS24, TS25, TS26, TS27, TS28, TS29, TS30, TS31 TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10, TS11, TS12, TS13, TS14, TS15, TS16, TS17, TS18, TS19, TS20, TS21, TS22, TS23, TS24, TS25, TS26, TS27, TS28, TS29, TS30, TS31 None None None E1/T1 port None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SRN Subrack No. BSC6900 ADD SUBRACK(Mandatory)SET CLK(Mandatory) Number of the subrack MRFD-210301Configuration Management Interval Type 1~11 1~11 None None None None None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
SRN Subrack No. BSC6900 ADD MTP3LNK(Mandatory)ADD ADJNODE(Mandatory)ADD SCTPLNK(Mandatory)ADD RSCGRP(Mandatory)SET PHBMAP(Mandatory)ADD ATERE1T1(Mandatory)ADD PBE1T1(Mandatory)ADD AE1T1(Mandatory)BLK AE1T1(Mandatory)ADD ABISLOADSHARE(Mandatory) Subrack No.. None None Interval Type 0~11 0~11 None None None BSC6900None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
SRN Control subrack No. BSC6900 ADD M3LNK(Mandatory) SPU subrack No. of controlling the M3UA signaling link. None None Interval Type 0~11 0~11 None None None BSC6900None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
SRN BM Subrack No BSC6900 BLK ATERE1T1(Mandatory) It is one key field of identifying the Ater timeslot and indicates the subrack No. of the Ater interface timeslot. None None Interval Type 0~11 0~11 None None None E1/T1 linkNone Read & Write N (No impact on the UE in idle mode) Not involved Not involved 1. The block of Ater interface must be configured. 2. If the BSC is configured to the integrated BMTC or A over IP is configured, the configuration does not support the operation. 3. If the block operation is applicable to only the ATERTS of the BM subrack. You are not allowed to perform the block operation from the primary BM subrack to the secondary BM subrack.
SRN Subrack No. BSC6900 COL LOG(Optional) Number of the subrack. None None Interval Type 0~11 0~11 None None None BSC6900None Read & Write Not Invovled Not Invovled Not involved None
srn Subrack No. BSC6900 EXP ALMLOG(Optional)STAALMLOG(Optional)ADD OBJALMSHLD(Mandatory) Number of the subrack where the indicator alarm to be queried is generated MRFD-210304Faulty Management Interval Type 0~11 0~11 None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SRN Subrack No. BSC6900 ADD ETHMD(Mandatory)ADD ETHTRK(Mandatory)ADD ETHTRKLNK(Mandatory)ADD ETHTRKIP(Mandatory)STR ETHMIRRORPORT(Mandatory) The subrack number for running this command None None Interval Type 0~11 0~11 None None None BSC6900None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
SRN Subrack No. BSC6900 ADD GCBSADDR(Mandatory)SET TCPLYVOICE(Mandatory)SET TCPARA(Mandatory) The subrack number uniquely identifies a subrack. MRFD-210301Configuration Management Interval Type 0~11 0~11 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SRN Subrack No. BSC6900 ADD GIURGCONN(Mandatory) Subrack No. of the subsystem where the Iur-g common connection is established MRFD-211402MBSC Load Balancing Interval Type 0~11 {0~11} None None None BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SRN Subrack No. BSC6900 SWP BTSRING(Optional)SWP BTSOMLLINK(Optional)ADD TRXBIND2PHYBRD(Mandatory)SET BTSFMUABP(Mandatory)SET BTSNFCBBP(Mandatory)SET BTSPMUBP(Mandatory)SET BTSAPMUBP(Mandatory)SET BTSDATUBP(Mandatory)SET BTSDEMUBP(Mandatory)SET BTSDFCUBP(Mandatory)SET BTSDHEUBP(Mandatory)SET BTSDOMUBP(Mandatory)SET BTSDPMUBP(Mandatory)SET BTSDTMUBP(Mandatory)SET BTSDGPSBP(Mandatory)SET BTSDDPUBP(Mandatory)SET BTSUSCUBP(Mandatory)SET BTSRXUBP(Mandatory)ADD BTSRXU2LOCGRP(Mandatory)ADD BTSBINDLOCGRP(Mandatory)ADD BTSANTFEEDERBRD(Mandatory)ADD BTSBRD(Mandatory)ADD BTSRXUBRD(Optional)ADD BTSTRXBRD(Mandatory)SET BTSENVALMPORT(Mandatory)ADD BTSOBJALMSHLD(Mandatory)SET BTSANTFEEDERCONNECT(Mandatory)LOD RETANTCFG(Mandatory)SET BTSANTANGLE(Mandatory)SET BTSCLKPARA(Mandatory)SET BTSCAVFRQ(Mandatory)SET BTSPMUDEF(Mandatory)SET BTSTMA(Mandatory)SET RETANTENB(Mandatory)STR BTSBATTTST(Mandatory)STR RETANTSCAN(Mandatory)STR TRANSPERFTST(Optional)SWP BTSBRD(Mandatory)SET BTSENVALM(Mandatory)CHG BTSPTUSHKTM(Mand Number of the subrack where the BTS board is located GBFD-111202O&M of BTS Interval Type 0~254 0~254 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SRN Subrack No. BSC6900 ADD BTSBFD(Optional)ADD BTSIPRTBIND(Optional) Number of the subrack where the BTS board is located GBFD-118609IP Fault Detection Based on BFD Interval Type 0~254 0~254 None 0 None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SRN Subrack No. BSC6900 ADD NSE(Mandatory) Subrack number of the XPU bound to the NSE. MRFD-210301Configuration Management Interval Type 0~11 0~11 None None None BSC None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
SRN Subrack No. BSC6900 ADD PBSL(Mandatory) Subrack No. of board to which Pb signaling link belongs. GBFD-111203O&M of BSC Interval Type 0~11 0~11 None None None BSC None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
SRN Port Subrack No. BSC6900 ADD BTSSFPMODE(Optional)SET BTSFORBIDTS(Optional)SET BTSOMLTS(Optional)ADD BTSTOPCONFIG(Optional)SET BTSETHPORT(Optional)ADD BTSPPPLNK(Optional)ADD BTSMPLNK(Optional)ADD BTSETHMA(Optional)ADD BTSETHLCMEP(Optional) Number of the subrack where the port is located GBFD-111202O&M of BTS Interval Type 0~254 0~254 None None None BTS None Read & Write Y BTS Less than 5 minutes None
SRN Subrack No. BSC6900 ADD BTSCONNECT(Mandatory) Subrack number of the BSC board that is connected to the BTS GBFD-111202O&M of BTS Interval Type 0~11 0~11 None None None BTS None Read & Write Y BTS Less than 5 minutes This parameter can be modified only when the BTS is deactivated.
SRN1 Subrack 1 No BSC6900 ADD SRCONPATH(Mandatory) Number of the subrack of one end of the inter-subrack connection channel GBFD-111203O&M of BSC Interval Type 0~11 0~11 None None None Control plane link None Read & Write Y Subrack connection path Less than 5 minutes 1. The command is used for the configuration when the TDM resources exist between two subracks.2. Each subrack must be the BM subrack or TC subrack.
SRN2 Subrack 2 No BSC6900 ADD SRCONPATH(Mandatory) Number of the subrack of the other end of the inter-subrack connection channel GBFD-111203O&M of BSC Interval Type 0~11 0~11 None None None BSC6900None Read & Write Y Subrack connection path Less than 5 minutes 1. The command is used for the configuration when the TDM resources exist between two subracks.2. Each subrack must be the BM subrack or TC subrack.
SRName Subrack name BSC6900 ADD SUBRACK(Mandatory) Name of the subrack to be added MRFD-210301Configuration Management String Type None 1~249 characters None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SRNO Tributary No. BSC6900 SET BTSTMA(Mandatory) Number of the tributary GBFD-111202O&M of BTS Interval Type 0~5 0~5 None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SRT Subrack type BSC6900 SET CLK(Mandatory) Type of the subrack MRFD-210502BSC/RNC Clock Enumeration Type MPS, EPS, TCS MPS, EPS, TCS None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved If the interface board clock source of the MPS/TCS subrack is set, you can set the 8 kHz output clock source. For the MPS and TCS, you can set the backplane board 8K output clock as the clock source of the interface board. For the EPS, you cannot perform the setting.
srtord Sort Order BSC6900 EXP ALMLOG(Optional) Sequence of alarm records MRFD-210304Faulty Management Enumeration Type DES, ASC DES, ASC None DES None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SRVLW User Data Load Weight BSC6900 ADD NSVLLOCAL(Optional) Traffic local weight over the local NSVL. When this parameter is set to a larger value, the NS is more likely to select this IP point according to the load sharing function of the NSVC link of the IP network if the NS sends a data message. GBFD-118603Gb over IP Interval Type 0~255 0~255 None 100 100 NSE None Read & Write Y NSE Services are interrupted until "SRVLW" is not set to 0. The ratio of Gb interface signalling message s sent through local NSVLs is affected when this parameter is modified. When this NSVL is the last NSVL of the normal state in the NSE, if "SRVLW" is set to 0, all the packet services of the local NSE are interrupted.
SRVLW User Data Load Weight BSC6900 ADD NSVLREMOTE(Optional) Traffic local weight over the remote NSVL. When this parameter is set to a larger value, the NS is more likely to select this IP point according to the load sharing function of the NSVC link of the IP network if the NS sends a data message. GBFD-118603Gb over IP Interval Type 0~255 0~255 None 100 100 NSE None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SRVPRIPOLICY Service Priority Policy BSC6900 SET BTSPSUFP(Optional) The parameter specifies which type of service TRXs should be preferentially processed when the PSU is faulty. GBFD-111202O&M of BTS Enumeration Type GSM_PRIOR(GSM Traffic Prior), UMTS_PRIOR(UMTS Traffic Prior) GSM_PRIOR, UMTS_PRIOR None GSM_PRIOR None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SRVTYPE Service Type BSC6900 ADD BTSABISMUXFLOW(Mandatory) Service type of the IP interface board. The service type can be CS speech, CS data, PS high priority, or PS low priority. GBFD-118605IP QOS Enumeration Type CSVOICE(CS Voice), CSDATA(CS Data), PSHIGHPRI(PS High PRI), PSLOWPRI(PS Low PRI) CSVOICE, CSDATA, PSHIGHPRI, PSLOWPRI None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SSBQPUNISH Penalty Level after BQ HO BSC6900 SET GCELLHOFITPEN(Optional) After a handovr due to bad quality is successful, the penalty on the original serving cell is performed within the "Penalty Time after BQ HO": the receive level of the original serving cell is decreased by "Penalty Level after BQ HO", to prevent ping-pong handovers. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 0~63 0~63 dB None 63 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SSCPUAVEUSAGEALMTHD CPU occupancy alarm clearance threshold BSC6900 SET CPUTHD(Optional) CPU usage alarm clearance threshold MRFD-210304Faulty Management Interval Type 20~99 20~99 per cent None 75 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SSCPUMAXUSAGEALMTHD CPU occupancy alarm threshold BSC6900 SET CPUTHD(Optional) CPU usage alarm threshold. When the CPU usage exceeds the threshold, a CPU usage alarm is reported. "CPU occupancy alarm clearance threshold" is smaller than "CPU occupancy alarm threshold". MRFD-210304Faulty Management Interval Type 30~100 30~100 per cent None 85 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SSDSPAVEUSAGEALMTHD DSP occupancy alarm clearance threshold BSC6900 SET CPUTHD(Optional) DSP usage alarm clearance threshold. When the DSP usage is lower than the threshold, the DSP usage alarm is cleared. MRFD-210304Faulty Management Interval Type 20~99 20~99 per cent None 80 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SSDSPMAXUSAGEALMTHD DSP occupancy alarm threshold BSC6900 SET CPUTHD(Optional) DSP usage alarm threshold. When the DSP usage exceeds the threshold, a DSP usage alarm is reported. "DSP occupancy alarm clearance threshold" is smaller than "DSP occupancy alarm threshold". MRFD-210304Faulty Management Interval Type 30~100 30~100 per cent None 80 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SSLENSD Filter Length for TCH Level BSC6900 SET GCELLCHMGAD(Optional) When the network receives measurement reports, the measurement values in several straight measurement reports are filtered to reflect the radio operating environment for the sake of accuracy. This parameter specifies the number of successive measurement reports that are used to determine the signal strength on traffic/data channels. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 1~32 1~32, step:480 for TCH and 470 for SDCCH ms None 6 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SSLENSI Filter Length for SDCCH Level BSC6900 SET GCELLCHMGAD(Optional) When the network receives measurement reports, the measurement values in several straight measurement reports are filtered to reflect the radio operating environment for the sake of accuracy. The parameter specifies the number of successive measurement reports that are used to determine the signal strength on signaling channel. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 1~32 1~32, step:480 for TCH and 470 for SDCCH ms None 2 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SSN Subsystem No. BSC6900 STR BKP(Optional)STR CPUUSAGETST(Mandatory)ULD RSTINFO(Mandatory)ADD XPUVLAN(Mandatory)CMP TBLDATA(Mandatory) Number of the subsystem MRFD-210301Configuration Management Interval Type 0~7 0~7 None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SSN Subsystem No. BSC6900 ADD GIURGCONN(Mandatory) No. of the subsystem where the Iur-g common connection is established MRFD-211402MBSC Load Balancing Interval Type 0~7 {0~7} None None None BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
sssn Start Sync Serial No. BSC6900 EXP ALMLOG(Optional) Start synchronization number of the alarm record MRFD-210304Faulty Management Interval Type 1~2147483646 1~2147483646 None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SSTAPUNISH Penalty Level after TA HO BSC6900 SET GCELLHOFITPEN(Optional) After the time advancing handover is successful, the penalty on the original serving cell is performed within the "Penalty Time after TA HO": the receive level of the original serving cell is decreased by "Penalty Level after TA HO", to prevent ping-pong handovers. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 0~63 0~63 dB None 63 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ST StartTime BSC6900 SET TZ(Mandatory) Start of DST MRFD-210301Configuration Management Compound Type HOUR, MIN, SEC HOUR, MIN, SEC None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ST Start Time BSC6900 EXP LOG(Optional) The operation time of the log record is posterior to this time. If this parameter is not specified, the start time is not limited. GBFD-111203MRFD-210305 O&M of BSCSecurity Management Compound Type year, month, date, hour, min, sec 2000-1-1 00:00:00~2037-12-31 23:59:59 None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ST Start Time BSC6900 ADD SUBTSK(Mandatory) If the time mode is set to "DAILY_T", "WEEKLY_T", or "MONTHLY_T", you should set this parameter. GBFD-111203O&M of BSC Compound Type hour, min 00:00~23:59 None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ST Start Time BSC6900 COL LOG(Optional) The operation time of the log record is posterior to this time. If this parameter is not specified, the start time is not limited. GBFD-111203MRFD-210305 O&M of BSCSecurity Management Compound Type year, month, date, hour, min, sec 2000-1-1 00:00:00~2037-12-31 23:59:59 None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
st Start Time BSC6900 EXP ALMLOG(Optional) Start time of the alarm record. By default, the start time is 00:00:00. MRFD-210304Faulty Management Compound Type hour, min, sec 00:00:00~23:59:59 None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
st Start Time BSC6900 STA ALMLOG(Optional) Start time of the alarm record. By default, the start time is 00:00:00. MRFD-210304Faulty Management Compound Type hour, min, sec 00:00:00~23:59:59 None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ST Start time BSC6900 ADD GSMSCB(Mandatory) A key parameter that indicates the date and time when the BSC broadcasts cell messages GBFD-113602Simplified Cell Broadcast Compound Type year, month, day, hour, min, sec 1970-1-1 00:00:00~2538-12-31 23:59:59 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
startaid Start Alarm ID BSC6900 EXP ALMLOG(Optional)STAALMLOG(Optional) Start number of the alarm record MRFD-210304Faulty Management Interval Type 1~65535 1~65535 None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
STARTCBSHORTMSGFLOWCTRL Prefer Variable Bitmap Code BSC6900 SET BSCFCPARA(Optional) Whether to preferentially use the variable bitmap code when encoding the FH frequency in the assignment or handover command GBFD-113701Frequency Hopping (RF hopping, baseband hopping) Enumeration Type NO(No), YES(Yes)NO, YES None None YES BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved In principle, you should not configure the frequencies on the P frequency band and on the E frequency band in one MA group. If the frequencies on the P frequency band and on the E frequency band are configured in one MA group, some MSs may not process calls.In this case, you can set this parameter to No.After that, if some other MSs cannot process calls, set this parameter to Yes and divide the MA group.
STARTCHREQARRIVALCTRL CHAN REQ Arrival Control BSC6900 SET BSCFCPARA(Optional) This parameter indicates whether the arrival of channel request messages is controlled. GBFD-111705GSM Flow Control Enumeration Type NO(No), YES(Yes)NO, YES None None YES BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
STARTCIC Start CIC BSC6900 BLK ACIC(Mandatory) It indicates the start CIC of the A interface CIC segment. When operation mode is set to OPC index, DPC group index, BSC ID, or CIC, the parameter is mandatory. GBFD-111803A Interface Circuit Management Interval Type 0~65535 0~65535 None None None E1/T1 linkWhen the value of "OPMODE" of "BLK ACIC" is BYCICRANGE, the value of STARTTS needs to be set. Read & Write N (No impact on the UE in idle mode) Not involved Not involved 1. The block of A interface must be configured. 2. If A over IP is configured, the configuration does not support the operation.
5/5/2014
Confidential Information of Huawei.
No Spreading without Permission
Page18of42
226347869.xls.ms_office Security Level:
STARTCIC Start CIC BSC6900 BLK PBCIC(Mandatory) It indicates the start CIC of the Pb interface CIC segment.2. If the search object mode is set to search by the specified range, the parameter is mandatory. GBFD-111203O&M of BSC Interval Type 0~65535 0~65535 None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
StartDayDSTPA Prohibit Close TRX Power Start Day BSC6900 ADD BSCDSTPADATE(Mandatory) Start date of a period during which the dynamic shutdown of a TRX power amplifier is disabled. GBFD-111602TRX Power Amplifier Intelligent Shutdown Interval Type 1~31 1~31 None None None BSC6900The following condition must be met: the value of "EndDayDSTPA" is greater than that of "StartDayDSTPA" when "EndMonthDSTPA" and "StartMonthDSTPA" are set to a same value. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
STARTHEATTEMP Heater Startup Temperature BSC6900 SET BTSDHEUBP(Optional) When the environment temperature reaches the specified value of this parameter, the heater is started.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. GBFD-111202O&M of BTS Interval Type -990~400 -99~40 (step: 0.1) degree Celsius None -100 BTS The value of this parameter must be smaller than "Heater shutdown Temperature". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
StartMonthDSTPA Prohibit Close TRX Power Start Month BSC6900 ADD BSCDSTPADATE(Mandatory) Start month when the BSC disables the function of dynamic shutdown of TRX power amplifier. GBFD-111602TRX Power Amplifier Intelligent Shutdown Enumeration Type JAN(Jan.), FEB(Feb.), MAR(Mar.), APR(Apr.), MAY(May), JUN(Jun.), JUL(Jul.), AUG(Aug.), SEP(Sep), OCT(Oct.), NOV(Nov.), DEC(Dec) JAN, FEB, MAR, APR, MAY, JUN, JUL, AUG, SEP, OCT, NOV, DEC None None None BSC6900The following condition must be met: "EndMonthDSTPA" >= "StartMonthDSTPA". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
STARTPGARRIVALCTRL Paging Arrival Control BSC6900 SET BSCFCPARA(Optional) This parameter indicates whether the arrival of paging messages are controlled. GBFD-111705GSM Flow Control Enumeration Type NO(No), YES(Yes)NO, YES None None YES BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
STARTPSRESREQARRIVALCTRL PS Resource REQ Arrival Control BSC6900 SET BSCFCPARA(Optional) This parameter indicates whether the arrival of PS resource request messages is controlled. GBFD-111705GSM Flow Control Enumeration Type NO(No), YES(Yes)NO, YES None YES YES BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
STARTSUBTS Start Sub Timeslot NO. BSC6900 SET BTSFORBIDTS(Optional) Number of the start sub-timeslot GBFD-111202O&M of BTS Enumeration Type 0(0), 2(2), 4(4), 6(6) 0, 2, 4, 6 None None None BTS None Read & Write Y BTS Less than 5 minutes None
STARTTIME Fallback Start Time BSC6900 SET BTSFALLBACK(Optional) Time for which the BTS waits to start the fallback function after the OML is interrupted. With this parameter, the BTS does not start the fallback function when the OML is interrupted transiently. GBFD-510309Group Call Reliability Enhancing Interval Type 60~600 60~600 s None 240 BTS This parameter is valid only when "ENABLE" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter is supported only by the following types of BTSs: BTS3012, BTS3006C, BTS3012AE, BTS3012 II, and BTS3002E.
StartTimeTACloseTrxPA Time When the Function Is Enabled BSC6900 SET BSCDSTPA(Optional) Start time when the BSC start TRX power amplifier dynamically every day. GBFD-111602TRX Power Amplifier Intelligent Shutdown Compound Type hour, min, sec 00:00~23:59 None None 0:00 BSC6900When "BSCDynSwitchTrxPAAllow" is set to YES, this parameter must be set. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
STARTTS Start TS BSC6900 BLK ATERE1T1(Mandatory) It indicates the start CIC of the Ater interface CIC segment. GBFD-111801Ater Interface 4:1 Multiplexing Interval Type 8~255 8~255 None None None E1/T1 linkWhen the value of "OPMODE" of "BLK ATERE1T1" is BYCICRANGE, the value of STARTTS needs to be set. Read & Write N (No impact on the UE in idle mode) Not involved Not involved 1. The block of Ater interface must be configured. 2. If the BSC is configured to the integrated BMTC or A over IP is configured, the configuration does not support the operation. 3. If the block operation is applicable to only the ATERTS of the BM subrack. You are not allowed to perform the block operation from the primary BM subrack to the secondary BM subrack.
STARTTS Start TS BSC6900 BLK AE1T1(Mandatory) It indicates the start CIC of the A interface CIC segment. When Operation mode is set to subrack No., slot No., port No., or CIC, the parameter is mandatory. GBFD-111803A Interface Circuit Management Interval Type 1~31 1~31, step:8 None None None E1/T1 linkWhen the value of "OPMODE" of "BLK AE1T1" is BYCICRANGE, the value of STARTTS needs to be set. Read & Write N (No impact on the UE in idle mode) Not involved Not involved 1. The block of A interface must be configured. 2. If the BSC is configured to the integrated BMTC or A over IP is configured, the configuration does not support the operation. 3. If the block operation is applicable to only the AE1T1 of the BM subrack. You are not allowed to perform the block operation from the primary BM subrack to the secondary BM subrack.
STARTTS Start Timeslot NO. BSC6900 SET BTSFORBIDTS(Mandatory) Number of the start timeslot GBFD-111202O&M of BTS Interval Type 1~31 1~31 None None None BTS None Read & Write Y BTS Less than 5 minutes None
STC Smart Temperature Control BSC6900 SET BTSFMUABP(Optional) Whether to enable the smart temperature control mechanism of the FMUA. Smart temperature control refers to the mechanism adopted by the FMUA to adjust the fan speed, and thus to regulate the temperature according to the environment temperature.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. GBFD-111202O&M of BTS Enumeration Type DISABLED(Disabled), ENABLED(Enabled) DISABLED, ENABLEDNone None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
STC Smart Temperature Control BSC6900 SET BTSNFCBBP(Optional) Whether to enable the smart temperature control mechanism of the NFCB. Smart temperature control refers to the mechanism adopted by the NFCB to adjust the fan speed, and thus to regulate the temperature according to the environment temperature. GBFD-111202O&M of BTS Enumeration Type DISABLED(Disabled), ENABLED(Enabled) DISABLED, ENABLEDNone DISABLED None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
STCIC Start CIC BSC6900 ADD AE1T1(Mandatory) Number of the start CIC. The C/C of each E1/T1 timeslot can be calculated on the basis of this parameter. Assume that the start CIC is 100, the CIC of the E1 timeslots on the A interface will automatically be set to 100, 101, 102, 103, and so on. Assume that the CIC of an E1 timeslot is 65535, the CICs of all successive E1 timeslots are all 65535. GBFD-111803A Interface Circuit Management Interval Type 0~65535 0~65535 None None None E1/T1 linkNone Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
STCN Out Port Cabinet No. BSC6900 ADD BTSMONITORTS(Optional) Number of the cabinet where the outgoing port of the BTS is located GBFD-111202O&M of BTS Interval Type 0~62 0~62 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
STD Start Date BSC6900 ADD OP(Mandatory) Start date. The input format is YYYY&MM&DD. GBFD-111203MRFD-210305 O&M of BSCSecurity Management Compound Type year, month, day 2000-1-1~2037-12-31None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
STEP Measurement Step BSC6900 STR NCS(Mandatory) Number of frequencies measured in each group (excluding the frequencies in the original BA table). GBFD-5109012G/3G Neighboring Cell Automatic Optimization Interval Type 1~32 1~32 None None None BSC6900To ensure that all the frequencies can be measured within 24 hours, the following condition must be met: ("PERIOD" x 15) x (total number of frequencies to be measured/"STEP") < (24 x 60). Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
STFLG Satellite flag BSC6900 ADD MTP3LNK(Optional) Satellite flag. None None Enumeration Type NO(NO), YES(YES) NO, YES None NO NO MTP3 linkNone Read & Write Not involved Not involved Not involved The parameter cannot be modified.
STIME Start Time BSC6900 STR BTSLOG(Optional) Start time GBFD-111202O&M of BTS Compound Type hour, min, sec 00:00:00~23:59:59 None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
STIRCALLOWED EICC Allowed BSC6900 SET GCELLSOFT(Optional) Whether to enable the EICC algorithm GBFD-115821EICC Enumeration Type NO(No), YES(Yes)NO, YES None None NO Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
STOPSI5SWITCH Stop Send SI 5/5bis/5ter after Encrypt BSC6900 SET GCELLSOFT(Optional) This parameter specifies whether the sending of system information 5, 5bis, and 5ter can be stopped on the SACCH on the SDCCH after the BTS issues a ciphering command. GBFD-113521Encrypted Network Management Enumeration Type OFF(Off), ON(On) OFF, ON None None OFF Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
STOPTIME Fallback Stop Time BSC6900 SET BTSFALLBACK(Optional) Time for which the BTS waits to stop the fallback function after the OML is set up. With this parameter, the BTS does not stop the fallback function when the OML is set up transiently. GBFD-510309Group Call Reliability Enhancing Interval Type 60~300 60~300 s None 120 BTS This parameter is valid only when "ENABLE" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter is supported only by the following types of BTSs: BTS3012, BTS3006C, BTS3012AE, BTS3012 II, and BTS3002E.
STP STP function switch BSC6900 ADD N7DPC(Optional) Whether to enable the signaling point with the signaling transfer function. None None Enumeration Type OFF(OFF), ON(ON) OFF, ON None OFF OFF SCCP None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
STPMODE Stop mode BSC6900 STR CPUUSAGETST(Mandatory) Mode of stopping the CPU usage test MRFD-210301Configuration Management Enumeration Type MANULSTP(Manual stop), AUTOSTP(Automatic stop) MANULSTP, AUTOSTPNone None None None None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
STPN Out-BTS Port No. BSC6900 ADD BTSMONITORTS(Mandatory) Number of the outgoing port of the BTS where the monitoring timeslot is located GBFD-114701Semi-Permanent Connection Interval Type 0~23 0~23 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
STRTM Start time BSC6900 SET GCELLFREQSCAN(Optional) Start time of frequency scanning GBFD-112401Cell Frequency Scan Compound Type hour, min, sec HOUR{0~23}, MIN{0~59}, SEC{0~59} None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
STSN Out Port Slot No. BSC6900 ADD BTSMONITORTS(Optional) Number of the slot where the outgoing port of the BTS is located GBFD-111202O&M of BTS Interval Type 0~23 0~23 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
STSRN Out Port Subrack No. BSC6900 ADD BTSMONITORTS(Optional) Number of the subrack where the outgoing port of the BTS is located GBFD-111202O&M of BTS Interval Type 0~254 0~254 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
STSUBTS Out-BTS Sub Timeslot No. BSC6900 ADD BTSMONITORTS(Mandatory) Number of the sub-timeslot on the outgoing port of the BTS GBFD-111202O&M of BTS Interval Type 0~7 0~7 None None None BTS If the added monitoring timeslot works at 64 kbit/s, the sub-timeslots are numbered from 0. If the added monitoring timeslot works at 32 kbit/s, the sub-timeslots are numbered from 0 or 4. If the added monitoring timeslot works at 16 kbit/s, the sub-timeslots are numbered from 0, 2, 4, or 6. If the added monitoring timeslot works at 8 kbit/s, the sub-timeslots are numbered from any value among 0 to 7. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
STT Start Time BSC6900 ADD OP(Mandatory) Start time. The input format is HH&MM&SS. GBFD-111203MRFD-210305 O&M of BSCSecurity Management Compound Type hour, min, sec 00:00:00~23:59:59 None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
STTS Out-BTS Timeslot No. BSC6900 ADD BTSMONITORTS(Mandatory) Number of the timeslot on the outgoing port of the BTS GBFD-111202O&M of BTS Interval Type 1~31 1~31 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
STTYPE BTS Type BSC6900 SET BTSAUTODLDACTINFO(Optional) Type of the BTS. GBFD-111202O&M of BTS Enumeration Type BTS30(BTS30), BTS312(BTS312), BTS3001C(BTS3001C), BTS3001CP(BTS3001CP), BTS3002C(BTS3002C), BTS3012A(BTS3012A), BTS3006A(BTS3006A), BTS3012(BTS3012), BTS3006C(BTS3006C), BTS3002E(BTS3002E), BTS3012AE(BTS3012AE), BTS3012_II(BTS3012 II), DBS3900_GSM(DBS3900 GSM), BTS3900_GSM(BTS3900 GSM), BTS3900A_GSM(BTS3900A GSM), DBS3036(DBS3036), BTS3036(BTS3036), BTS3036A(BTS3036A), BTS3900L_GSM(BTS3900L GSM), BTS3900B_GSM(BTS3900B GSM), BTS3900E_GSM(BTS3900E GSM) BTS30, BTS312, BTS3001C, BTS3001CP, BTS3002C, BTS3012A, BTS3006A, BTS3012, BTS3006C, BTS3002E, BTS3012AE, BTS3012_II, BTS3900_GSM, BTS3900A_GSM, BTS3036, BTS3036A, BTS3900L_GSM, BTS3900B_GSM, BTS3900E_GSM None None None BTS If "Work Mode for Auto Download Activation" is "TMUAUTOACT", the BTS type must be consistent with the actual BTS type. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SUBBSCTID ID of slave BSC in TC Pool BSC6900 BLK ACIC(Mandatory) BSC ID in the TC pool when block or unblock A interface circuit. GBFD-113726TC Pool Interval Type 1~15 1~15 None None None E1/T1 linkWhen SUBBSC is selected for "BSC flag", this parameter should be set. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SUBBSCTID ID of slave BSC in TC Pool BSC6900 ADD AE1T1(Mandatory) BSC ID in the TC pool when add A interface E1/T1. GBFD-113726TC Pool Interval Type 1~15 1~15 None None None E1/T1 linkWhen SUBBSC is selected for "BSC flag", this parameter should be set. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SUBCMD Command Parameter BSC6900 STR BTSLOG(Optional) Command string that is transparently transmitted to the BTS GBFD-111202O&M of BTS String Type None 1~64 characters None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SUBFRAMELEN Max subframe length[byte] BSC6900 ADD IPMUX(Optional) Maximum sub-frame length. This parameter indicates the maximum sub-frame length for multiplexing. If the length of a sbu-frame exceeds this value, it is not multiplexed. GBFD-118604GBFD-118610 Abis MUXUDP MUX for A Transmission Interval Type 16~1023 16~1023 byte 127 127 IP Path None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The adjacent node ID must be configured.
SUBFRAMETHRES MUX Sub Frame Threshold BSC6900 ADD BTSABISMUXFLOW(Optional) Multiplexing subframe threshold. The data stream to be multiplexed on the same multiplexing channel must be of the same type, and the length of the packet before multiplexing cannot exceed the multiplexing subframe threshold. If the length of a packet exceeds the multiplexing subframe threshold, the packet is transmitted without being multiplexed. GBFD-118604Abis MUX Interval Type 16~1023 16~1023 byte 127 127 BTS This parameter must meet the following requirements: The sum of the value of "MUX Sub Frame Threshold" and 8 must be smaller than the value of "MUX Packet Length Threshold". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SUBID Subtask ID BSC6900 ADD SUBTSK(Mandatory)ADD SUBCMD(Mandatory) Number of the scheduled subtask GBFD-111203O&M of BSC Interval Type 1~50 1~50 None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SUBNET Subnet No. BSC6900 SET SUBNET(Mandatory) subnet No. in a BSC. None None Interval Type 1~124,128~189 1~124, 128~189 None None None BSC6900None Read & Write Not involved Not involved Not involved None
SUBRESPREEMPTFLG Sublink Resources Preemption Switch BSC6900 SET GCELLSOFT(Optional) This parameter specifies whether the CS services preempt the sublink resources of PS services. GBFD-117301Flex Abis Enumeration Type NO(No), YES(Yes)NO, YES None None NO Cell This parameter is valid when "FLEXABISMODE" in the "MOD BTS" command is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SUBRESPREEMPTFLG Sub Res Preempt Flag BSC6900 SET BTSFLEXABISPARA(Optional) Whether to allow the CS services to preempt the sublink resources of PS services when the Abis resources are congested GBFD-117301Flex Abis Enumeration Type NO(NO), YES(YES) NO, YES None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SUBTS Sub Timeslot NO. BSC6900 SET BTSOMLTS(Mandatory) Number of the sub-timeslot on the port GBFD-111203O&M of BSC Enumeration Type 0(0), 2(2), 4(4), 6(6) 0, 2, 4, 6 None None None BTS None Read & Write Y BTS Less than 5 minutes None
SubVer Sub-Version No.of TMU BSC6900 SET BTSAUTODLDACTINFO(Mandatory) Sub-version No. of the TMU board. It is configured according to the actual situation. GBFD-111202O&M of BTS Interval Type 0~65535 0~65535 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SupportApplyUsedCic Support Apply Used A Cic BSC6900 SET OTHSOFTPARA(Optional) Whether the CIC circuits in use on the A interface can be assigned. When this parameter is set to YES and the MSC assigns new calls to an ongoing A interface circuit, the original calls (that are occupying the circuit) are released, and the circuit is used by the new calls. When this parameter is set to NO and the MSC assigns new calls to the ongoing A interface circuit, the new calls are rejected, and the original calls are not affected. GBFD-111803A Interface Circuit Management Enumeration Type NO(No), YES(Yes)NO, YES None None YES BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SUPPORTBAKCLK2SRC Use Back-up port for LINE2 BSC6900 SET CLK(Optional)Whether to use Back-up port for LINE2 MRFD-210502BSC/RNC Clock Enumeration Type NO(NO), YES(YES) NO, YES None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SUPPORTBAKCLKSRC Use Back-up port for LINE1 BSC6900 SET CLK(Optional)Whether to use Back-up port for LINE1 MRFD-210502BSC/RNC Clock Enumeration Type NO(NO), YES(YES) NO, YES None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SUPPORTCELLBROADCAST Support Cell Broadcast Name BSC6900 SET GCELLSBC(Optional) Whether to support the broadcast of the cell name GBFD-113602Simplified Cell Broadcast Enumeration Type NO(No), YES(Yes)NO, YES None None NO Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved When the simple cell broadcast function is enabled, the BSC provides the simple cell broadcast service if the CBC is not provided. The simple cell broadcast function is used to broadcast the messages that are not changed frequently.The simple cell broadcast function and the cell broadcast function provided by the CBC cannot be enabled simultaneously.
SUPPORTDL5TS Support High Multislot Class BSC6900 SET BSCPSSOFTPARA(Optional) whether to support the high multislot class. GBFD-119402MS High multislot classes Enumeration Type NOTSUPPORT(Not Support), SUPPORT(Support) NOTSUPPORT, SUPPORT None None NOTSUPPORT BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SUPPORTDTM Support DTM BSC6900 SET GCELLGPRS(Optional) Whether to support dual transfer mode (DTM). The DTM allows an MS to use the circuit switching service and the packet switching service at the same time. This function must be supported by the network side. GBFD-114151DTM Enumeration Type UNSUPPORT(Not Support), SUPPORT(Support) UNSUPPORT, SUPPORT None None None Cell This parameter is valid only when "GPRS" is set to SupportAsInnPcu. Read & Write Y Cell Less than 5 minutes None
SUPPORTEDA Support EDA BSC6900 SET BSCPSSOFTPARA(Optional) Whether to support EDA. GBFD-119401Extended Dynamic Allocation(EDA) Enumeration Type NOTSUPPORT(Not Support), SUPPORT(Support) NOTSUPPORT, SUPPORT None None NOTSUPPORT BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SUPPORTENDTM Support Enhanced DTM BSC6900 SET GCELLGPRS(Optional) Whether to support the enhanced DTM function. Comparing to the DTM, the enhanced DTM improves the CS setup and release. During the CS service setup, the PS service is not interrupted. GBFD-114151DTM Enumeration Type UNSUPPORT(Not Support), SUPPORT(Support) UNSUPPORT, SUPPORT None None None Cell This parameter is valid only when "GPRS" is set to SupportAsInnPcu and "SUPPORTDTM" is set to SUPPORT. Read & Write Y Cell Less than 5 minutes None
SupportIpSpanBtsLSwitch Support FE/GE SPAN BTS Local Switch BSC6900 SET BSSLS(Optional) Whether the FE/GE BTS supports inter-BTS local switching GBFD-117702BTS Local Switch Enumeration Type NO(No), YES(Yes)NO, YES None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SupportTFOCodecOptimize Support TFO Codec Optimize BSC6900 SET BSCBASIC(Optional) Support intracell handover to change the active speech version, then can increase the usage of TFO(Tandem Free Operation) to improve the speech quality. GBFD-115701TFO Enumeration Type NO(Not Support), YES(Support) NO, YES None None NO BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter should be set according to the requirements of the existing network.If this parameter is set to Yes, the voice signals are encoded only once at the originating MS and decoded only once at the terminating MS. This improves the QoS of the MS-to-MS call.The TFO function is performed only between an MS and another MS, not between a fixed-line phone and an MS. If the TFO function is enabled, a lot of GDPUC resources are occupied.
SVALUE S Value BSC6900 SET GCELLPRACH(Optional) Minimum timeslots between two successive channel requests. After sending the access request, if the MS does not receive the response message after waiting for the minimum timeslots between two successive channel requests, the MS resends the access request. GBFD-119110Access Enumeration Type T_12(12), T_15(15), T_20(20), T_30(30), T_41(41), T_55(55), T_76(76), T_109(109), T_163(163), T_217(217) T_12, T_15, T_20, T_30, T_41, T_55, T_76, T_109, T_163, T_217 None None T_20 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SVRIP Server IP BSC6900 ADD NSE(Mandatory) Server IP address used on the SGSN side in the IP subnet dynamic configuration procedure. GBFD-118603Gb over IP IP Address Type None 0.0.0.0~255.255.255.255 None None None NSE None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SVRPORT Server UDP Port BSC6900 ADD NSE(Mandatory) Server UDP port number used on the SGSN side in the IP subnet dynamic configuration procedure. GBFD-118603Gb over IP Interval Type 0~65535 0~65535 None None None NSE None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SW Switch BSC6900 SET ALMPORT(Optional) Operating state of the environment alarm port MRFD-210304Faulty Management Enumeration Type CLOSE(CLOSE), OPEN(OPEN) CLOSE, OPEN None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SW Switch Value BSC6900 SET NASTARSWITCH(Mandatory) Nastar independent measurement switch GBFD-111203MRFD-210302 O&M of BSCPerformance Management Enumeration Type OFF(CLOSE), ON(OPEN) ON, OFF None None OFF RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SW OMU Automatic Switchover Switch BSC6900 SET ASWPARA(Mandatory) If this parameter is set to "ON", you must set "OMU automatic switchover interval". Otherwise, "OMU automatic switchover interval" is not displayed. GBFD-111203O&M of BSC Enumeration Type ON, OFF ON, OFF None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SW Switch BSC6900 SET OBJAUTHSW(Mandatory) switch for authenticating objects. When the switch is enabled, the BSC system authenticates the BTS objects of the user; when the switch is disabled, the BSC system does not authenticate the BTS objects. GBFD-111203O&M of BSC Enumeration Type OFF(OFF), ON(ON) OFF/ON None None ON BSC6900None Read & Write Not involved Not involved Not involved None
SW Switch BSC6900 SET FACFG(Mandatory) The switch for the parameter indicated by TYPE parameter to be set. MRFD-210304Faulty Management Enumeration Type OFF(OFF), ON(ON) OFF/ON None None None None None Read & Write Not involved Not involved Not involved None
SW Switch BSC6900 SET BTSENVALMPORT(Mandatory) Whether to enable the alarm port GBFD-111202O&M of BTS Enumeration Type CLOSE(Close), OPEN(Open) CLOSE, OPEN None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SWEEK Start week BSC6900 SET TZ(Mandatory) Weekday on which DST starts MRFD-210301Configuration Management Enumeration Type SUN(Sunday), MON(Monday), TUE(Tuesday), WED(Wednesday), THU(Thursday), FRI(Friday), SAT(Saturday) SUN, MON, TUE, WED, THU, FRI, SAT None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
Switch Port switch BSC6900 SET SCUPORT(Mandatory) State of the panel port switch MRFD-210301Configuration Management Enumeration Type CLOSE, OPEN CLOSE, OPEN None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SWITCH Grace Protection Period Switch BSC6900 SET LICENSECTRL(Mandatory) Grace Protection Period Switch determines whether to enter the grace protection period. None None Enumeration Type ON, OFF ON, OFF None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SWITCH Bfd Protocol Switch BSC6900 SET BFDPROTOSW(Mandatory) Turn on or turn off the BFD protocol switch GBFD-118609IP Fault Detection Based on BFD Enumeration Type BFD_OFF(OFF), BFD_ON(ON) BFD_OFF, BFD_ON None None None None None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
SWITCHBACKFLAG Switch primary IP address flag BSC6900 ADD SCTPLNK(Optional) The field indicates whether the primary path can be switched when it is available. None None Enumeration Type NO(NO), YES(YES) NO, YES None YES YES SCTP linkNone Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SWITCHBACKHBNUM Switch back HB number BSC6900 ADD SCTPLNK(Optional) The association is smoothly switched over to the primary path after the number of heartbeat responses is received. None None Interval Type 1~254 1~254 None 10 10 SCTP linkNone Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SWITCHERLEVEL Alarm Valid Level Configuration BSC6900 SET BTSDHEUBP(Optional) Valid voltage level of the dry contact alarm. This parameter specifies the voltage level specifications of special Boolean alarms (No.1 to No.4). The alarm can be a high level alarm or a low level alarm. The bit 0 indicates high level alarm and the bit 1 indicates low level alarm. By default, all the alarms are high level alarms. GBFD-111202O&M of BTS Bit Field Type NO1, NO2, NO3, NO4 NO1, NO2, NO3, NO4None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SWITCHERLEVEL Common Alarm Valid Level CFG BSC6900 SET BTSRXUBP(Optional) Common alarm switch valid level [1-2]. This parameter consists of two bits, each of which indicates the active level of the corresponding Boolean alarm. MRFD-210304Faulty Management Bit Field Type NO1DISABLE, NO2DISABLE NO1DISABLE, NO2DISABLE None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SWITCHERLEVELX4 Common Alarm Valid Level CFG BSC6900 SET BTSRXUBP(Optional) Common alarm switch valid level [1-4]. This parameter consists of four bits, each of which indicates the active level of the corresponding Boolean alarm. MRFD-210304Faulty Management Bit Field Type NO1DISABLE, NO2DISABLE, NO3DISABLE, NO4DISABLE NO1DISABLE, NO2DISABLE, NO3DISABLE, NO4DISABLE None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SwitchParameter1 SwitchParameter1 BSC6900 SET SS7PATCHSWITCH(Optional) Set patch switch parameter1. None None Enumeration Type OFF(OFF), ON(ON) OFF, ON None OFF OFF BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved Change this parameter will impact the patch function controlled by switch 1.
SwitchParameter10 SwitchParameter10 BSC6900 SET SS7PATCHSWITCH(Optional) Set patch switch parameter10. None None Interval Type 0~4294967295 0~4294967295 None 0 0 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved Change this parameter will impact the patch function controlled by switch 10.
SwitchParameter2 SwitchParameter2 BSC6900 SET SS7PATCHSWITCH(Optional) Set patch switch parameter2. None None Enumeration Type OFF(OFF), ON(ON) OFF, ON None OFF OFF BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved Change this parameter will impact the patch function controlled by switch 2.
SwitchParameter3 SwitchParameter3 BSC6900 SET SS7PATCHSWITCH(Optional) Set patch switch parameter3. None None Enumeration Type OFF(OFF), ON(ON) OFF, ON None OFF OFF BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved Change this parameter will impact the patch function controlled by switch 3.
SwitchParameter4 SwitchParameter4 BSC6900 SET SS7PATCHSWITCH(Optional) Set patch switch parameter4. None None Enumeration Type OFF(OFF), ON(ON) OFF, ON None OFF OFF BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved Change this parameter will impact the patch function controlled by switch 4.
SwitchParameter5 SwitchParameter5 BSC6900 SET SS7PATCHSWITCH(Optional) Set patch switch parameter5. None None Enumeration Type OFF(OFF), ON(ON) OFF, ON None OFF OFF BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved Change this parameter will impact the patch function controlled by switch 5.
SwitchParameter6 SwitchParameter6 BSC6900 SET SS7PATCHSWITCH(Optional) Set patch switch parameter6. None None Enumeration Type OFF(OFF), ON(ON) OFF, ON None OFF OFF BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved Change this parameter will impact the patch function controlled by switch 6.
SwitchParameter7 SwitchParameter7 BSC6900 SET SS7PATCHSWITCH(Optional) Set patch switch parameter7. None None Interval Type 0~4294967295 0~4294967295 None 0 0 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved Change this parameter will impact the patch function controlled by switch 7.
SwitchParameter8 SwitchParameter8 BSC6900 SET SS7PATCHSWITCH(Optional) Set patch switch parameter8. None None Interval Type 0~4294967295 0~4294967295 None 0 0 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved Change this parameter will impact the patch function controlled by switch 8.
SwitchParameter9 SwitchParameter9 BSC6900 SET SS7PATCHSWITCH(Optional) Set patch switch parameter9. None None Interval Type 0~4294967295 0~4294967295 None 0 0 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved Change this parameter will impact the patch function controlled by switch 9.
SWITCHPORTNO Switch Port BSC6900 ADD BTSSFPMODE(Optional) Number of the switching port. If "Link Attribute" is set to "BBU", the switching port must be configured. The value ranges from 3 to 5. GBFD-111202O&M of BTS Interval Type 3~5 3~5 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SWOP Set Enable/Disable BSC6900 SET OPSW(Mandatory) Whether to enable the local user management function GBFD-111203MRFD-210305 O&M of BSCSecurity Management Enumeration Type OFF(OFF), ON(ON) OFF, ON None ON None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SWSEQ Start week sequence BSC6900 SET TZ(Mandatory) Sequence of the start week of DST MRFD-210301Configuration Management Enumeration Type FIRST(First), SECOND(Second), THIRD(Third), FOURTH(Fourth), LAST(Last) FIRST, SECOND, THIRD, FOURTH, LAST None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SYMOFFSET BTS Symbol Offset BSC6900 SET BTSAISS(Optional) Symbol offset of the BTS set manually. After the offset information of the BTS is collected, the symbol offset is adjusted. Adjustment value = Collected symbol offset relative to the reference BTS - (BTS symbol offset + BSC symbol offset). GBFD-118201Soft-Synchronized Network Interval Type 0~2500 0~2500 None 0 None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None.
SYNCCASE Sync case BSC6900 ADD GEXT3GCELL(Optional) Synchronization status. This parameter is used to identify different 3G cells. This parameter should be same with the configuration of 3G cells. GBFD-114302GSM/TD-SCDMA Interoperability Enumeration Type SyncCase1(Sync case 1), SyncCase2(Sync case 2) SyncCase1, SyncCase2 None None None Cell This parameter is valid only when "UTRANCELLTYPE" is set to TDD. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SYNCMETHOD Site Synchronization Method BSC6900 SET BTSOTHPARA(Optional) Site synchronization method. AISS stands for the air-interface soft synchronization method, and GPS stands for the GPS synchronization method. GBFD-117002IBCA (Interference Based Channel Allocation) Enumeration Type AISS(Air Interface Software Sync), GPS(GPS Synchronization) AISS, GPS None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SYNFLAG Synchronization flag. BSC6900 CMP BRDAREA(Optional) Automatic synchronization flag MRFD-210401BSC/RNC Software Management Enumeration Type TRUE, FALSE TRUE, FALSE None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SYNMODE Clock Synchronization Mode BSC6900 SET BTSIPCLKPARA(Mandatory) Synchronization mode of the IP clock GBFD-118606Clock over IP Enumeration Type CONSYN(Consecutive Synchronizing), INTERSYN(Intermittent Synchronizing) CONSYN, INTERSYNNone None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SYNTIMEDAY Inter Sync Period[Day] BSC6900 SET BTSIPCLKPARA(Optional) Interim synchronization period (in days). The BTS can re-initiate the synchronization only after the period. GBFD-118606Clock over IP Interval Type 1~7 1~7 d None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SYNTIMEHOUR Inter Sync Start Time[Hour] BSC6900 SET BTSIPCLKPARA(Optional) Interim synchronization period (in hours). The BTS can re-initiate the synchronization only after the period. GBFD-118606Clock over IP Interval Type 0~23 0~23 h None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SYNTIMEMIN Inter Sync Start Time[Minute] BSC6900 SET BTSIPCLKPARA(Optional) Interim synchronization period (in minutes). The BTS can re-initiate the synchronization only after the period. GBFD-118606Clock over IP Interval Type 0~59 0~59 min None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SYSCONTACT Contact mode of the manufacturer BSC6900 SET SYS(Optional) Contact way of the Base Station Controller supplier MRFD-210301Configuration Management String Type None 1~250 characters None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SYSDESC System description BSC6900 SET SYS(Optional) Description of the Base Station Controller MRFD-210301Configuration Management String Type None 1~250 characters None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SYSFLOWLEV System Flux Threshold for Load HO BSC6900 SET GCELLHOAD(Optional) The system flux level is the current flux control level of the system. A load handover is allowed only when the system flux is lower than the value of this parameter. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 0,8~11 0, 8~11 None None 10 Cell This parameter is valid only when "LOADHOEN" in "SET GCELLHOBASIC" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SYSLOCATION System Location BSC6900 SET SYS(Optional) Location of the Base Station Controller MRFD-210301Configuration Management String Type None 1~250 characters None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SysMsg10Allowed Send System Message 10 Allow BSC6900 SET BSCBASIC(Optional) Whether sending the system information type 10 message on the VGCS/VBS TCH is allowed. GBFD-510301Public Voice Group Call Service Enumeration Type NO(No), YES(Yes)NO, YES None YES YES BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SYSOBJECTID System ID BSC6900 SET SYS(Optional) Identifier of the Base Station Controller MRFD-210301Configuration Management String Type None 1~250 characters None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
SYSSERVICES System services BSC6900 SET SYS(Optional) Services provided by the Base Station Controller MRFD-210301Configuration Management String Type None 1~250 characters None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
T1 T1 BSC6900 SET BSSGPPARA(Optional) Timer T1, specifying the duration of monitoring the BVC blocking (unblocking) procedure. GBFD-119001Gb Interface Function Interval Type 1000~30000 1000~30000 ms None 3000 BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
T1 Time1 BSC6900 CHG BTSPTUSHKTM(Optional) Value of the first timer for the PTU handshake GBFD-118601Abis over IP Interval Type 1~60 1~60 s 5 None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
T10TMR Signalling route set test timer BSC6900 SET MTP3TMR(Optional) When the reception of a TFP causes unavailability of a route, this timer is started to regularly check whether the route is recovered. None None Interval Type 30000~60000 30000~60000 ms None None MTP3 linkNone Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
T12TMR Uninhibit ACK timer BSC6900 SET MTP3TMR(Optional) This timer is a protection timer waiting for an uninhibit acknowledgement message (LUA) from the peer end after an uninhibit message (LUN) is sent to the peer end. None None Interval Type 800~1500 800~1500 ms None None MTP3 linkNone Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
T13TMR Force uninhibit timer BSC6900 SET MTP3TMR(Optional) This timer is a protection timer waiting for a force uninhibit acknowledgement message (LUA) from the peer end after a force uninhibit message (LFU) is sent to the peer end. None None Interval Type 800~1500 800~1500 ms None None MTP3 linkNone Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
T14TMR Inhibition ACK timer BSC6900 SET MTP3TMR(Optional) This timer is a protection timer waiting for an inhibition acknowledgement message (LIA) from the peer end after an inhibition message (LIN) is sent to the peer end. None None Interval Type 2000~3000 2000~3000 ms None None MTP3 linkNone Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
T17TMR Link realignment timer BSC6900 SET MTP3TMR(Optional) This timer is started when a link fails to be started. The restart of the link is initiated after this timer expires. None None Interval Type 800~1500 800~1500 ms None None MTP3 linkNone Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
T1TMR Time-control changeover timer BSC6900 SET MTP3TMR(Optional) When a normal changeover cannot be initiated, services will be changed over to an alternative link after this timer expires to avoid disorder of data. None None Interval Type 800~1200 800~1200 ms None None MTP3 linkNone Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
T2 T2 BSC6900 SET BSSGPPARA(Optional) Timer T2, specifying the duration of monitoring the procedure of resetting SIG BVC and PTP BVC. GBFD-119001Gb Interface Function Interval Type 1000~120000 1000~120000 ms None 3000 BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
T2 Time2 BSC6900 CHG BTSPTUSHKTM(Optional) Value of the second timer for the PTU handshake GBFD-118601Abis over IP Interval Type 1~60 1~60 s 5 None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
T200 T200 BSC6900 SET BTSRINGATTR(Optional) Timer in the LAPD protocol. The value of the timer indicates the time when the LAPD link waits for the response or acknowledgement frame after sending the command frame. GBFD-117801Ring Topology Interval Type 6~240 60~2400 (step: 10) ms None When the transmission quality is good, the recommended settings are as follows: "Ring II Wait Time Before Switch" = 0; "Ring II Try Rotating Duration Time" = 60; "Ring II Rotating Penalty Time" = 0; "T200(10ms)" = 12; "T203(s)" = 1; and "N200" = 3.When the transmission quality is bad, the recommended settings are as follows: "Ring II Wait Time Before Switch" = 30; "Ring II Try Rotating Duration Time" = 60; "Ring II Rotating Penalty Time" = 0; "T200(10ms)" = 24; "T203(s)" = 3; and "N200" = 3. BTS The value of this parameter must be smaller than "T203". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
T200FACCHF T200 FACCH/F BSC6900 SET GCELLCCTMR(Optional) This parameter specifies the expiry value of timer T200 used for the FACCH/TCHF over the Um interface. For the function of timer T200 and the effect of the parameter, see the description of "T200 SDCCH". GBFD-111002Radio Link Management Interval Type 1~255 1~255, step: 5 ms None 50 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
T200FACCHH T200 FACCH/H BSC6900 SET GCELLCCTMR(Optional) This parameter specifies the expiry value of timer T200 used for the FACCH/TCHH over the Um interface. For the function of timer T200 and the effect of the parameter, see the description of "T200 SDCCH". GBFD-111002Radio Link Management Interval Type 1~255 1~255, step: 5 ms None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
T200SACCH3 T200 SACCH TCH SAPI3 BSC6900 SET GCELLCCTMR(Optional) This parameter specifies the expiry value of timer T200 used for the SACCH over the Um interface when the TCH supports SAPI3 services. For the function of timer T200 and the effect of the parameter, see the description of "T200 SDCCH". GBFD-111002Radio Link Management Interval Type 1~255 1~255, step: 10 ms None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
T200SACCHS T200 SACCH SDCCH BSC6900 SET GCELLCCTMR(Optional) This parameter specifies the expiry value of timer T200 used for the SACCH on the SDCCH.For the function of timer T200 and the effect of the parameter, see the description of "T200 SDCCH". GBFD-111002Radio Link Management Interval Type 1~255 1~255, step: 10 ms None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
T200SACCT0 T200 SACCH TCH SAPI0 BSC6900 SET GCELLCCTMR(Optional) This parameter specifies the expiry value of timer T200 used for the SACCH over the Um interface when the TCH supports SAPI0 services. For the function of timer T200 and the effect of the parameter, see the description of "T200 SDCCH". GBFD-111002Radio Link Management Interval Type 1~255 1~255, step: 10 ms None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
T200SDCCH T200 SDCCH BSC6900 SET GCELLCCTMR(Optional) This parameter specifies the timeout value of timer T200 used for the SDCCH over the Um interface.T200 prevents the data link layer from deadlock during data transmission. The data link layer transforms the physical link that is vulnerable to errors into a sequential non-error data link. The entities at the two ends of this data link use the acknowledgement retransmission mechanism.Each message must be confirmed by the peer end. In unknown cases, both ends are waiting if a message is lost. At this time, the deadlock of the system occurs. Therefore, the transmit end must establish a timer. When the timer expires, the transmit end regards that the receive end does not receive the message and then the transmit end retransmits the message. The number of retransmissions is determined by N200. T200 and the N200 ensure that the data link layer sequentially transmits data and that the transmission is free from errors. GBFD-111002Radio Link Management Interval Type 1~255 1~255, step: 5 ms None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
T200SDCCH3 T200 SDCCH SAPI3 BSC6900 SET GCELLCCTMR(Optional) This parameter specifies the expiry value of timer T200 when the SDCCH supports SAPI3 services.For the function of timer T200 and the effect of the parameter, see the description of "T200 SDCCH". GBFD-111002Radio Link Management Interval Type 1~255 1~255, step: 5 ms None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
T203 T203 BSC6900 SET BTSRINGATTR(Optional) Timer in the LAPD protocol. The value of the timer indicates the maximum duration for no frame exchange in the LAPD link. GBFD-117802Fast Ring Network Switch Interval Type 1~10 1~10 s None When the transmission quality is good, the recommended settings are as follows: "Ring II Wait Time Before Switch" = 0; "Ring II Try Rotating Duration Time" = 60; "Ring II Rotating Penalty Time" = 0; "T200(10ms)" = 12; "T203(s)" = 1; and "N200" = 3.When the transmission quality is bad, the recommended settings are as follows: "Ring II Wait Time Before Switch" = 30; "Ring II Try Rotating Duration Time" = 60; "Ring II Rotating Penalty Time" = 0; "T200(10ms)" = 24; "T203(s)" = 3; and "N200" = 3. BTS The value of this parameter must be greater than "T200". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
T22TMR Local inhibit test timer BSC6900 SET MTP3TMR(Optional) After a local link is inhibited, this timer is started to regularly check the management states at both ends of the link. None None Interval Type 180000~360000 180000~360000 ms None None MTP3 linkNone Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
T23TMR Remote inhibit test timer BSC6900 SET MTP3TMR(Optional) After a remote link is inhibited, this timer is started to regularly check the management states at both ends of the link. None None Interval Type 180000~360000 180000~360000 ms None None MTP3 linkNone Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
T2TMR Changeover ACK timer BSC6900 SET MTP3TMR(Optional) This timer is a protection timer waiting for an extended changeover acknowledgement message (XCA) from the peer end after an extended changeover order message (XCO) is sent to the peer end. None None Interval Type 1400~2000 1400~2000 ms None None MTP3 linkNone Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
T3 T3 BSC6900 SET BSSGPPARA(Optional) Timer T3. T3 is started after the message SUSPEND is received on the BSC side. T3 is stopped after the message SUSPEND ACK is received. GBFD-119001Gb Interface Function Interval Type 1000~10000 1000~10000 ms None 10000 BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
T3 Time3 BSC6900 CHG BTSPTUSHKTM(Optional) Value of the third timer for the PTU handshake GBFD-118601Abis over IP Interval Type 1~60 1~60 s 5 None None The value of this parameter must be smaller than or equal to "Time2[S]". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
T3105 T3105 BSC6900 SET GCELLHOAD(Optional) When the BTS sends physical information to the MS, the BTS starts the timer T3105.If the timer T3105 expires before the BTS receives the SAMB frame from MS, the BTS resends physical information to the MS and restarts the timer T3105. The maximum times for resending physical information is "Max Resend Times of Phy.Info.". For details, see GSM Rec. 04.08 and 08.58. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 0~255 0~255, step:10 ms None 7 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The physical information is sent over the FACCH. Every four TDMA frames are sent once over the FACCH, which takes 18 ms. If the T3105 timer is set to less than 18 ms, when the T3105 timer expires for the first time, the physical information needs to be retransmitted. But at this time, the previous physical information has not sent over the FACCH (the FACCH period is not reached).
T3115 T3115 BSC6900 SET GCELLGSMR(Optional) Timer for retransmitting the VGCS UPLINK GRANT message GBFD-510302Public Voice Broadcast Service Interval Type 1~255 1~255 s None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
T3168 T3168 BSC6900 SET GCELLPSBASE(Optional) T3168 is used to set the maximum duration for the MS to wait for the uplink assignment message. After the MS originates the uplink TBF setup request by sending the packet resource request or the channel request in the packet uplink acknowledge message, the timer T3168 is started to wait for the packet uplink assignment message on the network side. If the MS receives the packet uplink assignment message before T3168 expires, T3168 is reset. Otherwise, the MS originates the packet access request for four times. Then the MS regards this as the TBF setup failure. GBFD-114101GPRS Enumeration Type 500ms(500ms), 1000ms(1000ms), 1500ms(1500ms), 2000ms(2000ms), 2500ms(2500ms), 3000ms(3000ms), 3500ms(3500ms), 4000ms(4000ms) 500ms, 1000ms, 1500ms, 2000ms, 2500ms, 3000ms, 3500ms, 4000ms ms None 500ms Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
T3192 T3192 BSC6900 SET GCELLPSBASE(Optional) Duration of releasing the TBF after the MS receives the last data block. When the MS receives the RLC data block containing the flag identifying the last data block and confirms that all the RLC data blocks in the TBF are received, the MS sends the packet downlink acknowledge message containing the last flag acknowledgement and the timer T3192 is started. If the timer T3192 expires, the MS releases the TBF related resources and starts monitoring the paging channel. During TBF releasing, if the MS is the half duplex mode and receives the packet uplink assignment, the MS responds this command. During TBF releasing, if the MS is the half duplex mode and receives no packet uplink assignment message, the MS enters the packet idle mode. If the MS is in the dual transmission mode, the MS enters the special mode. GBFD-114101GPRS Enumeration Type 0ms(0ms), 80ms(80ms), 120ms(120ms), 160ms(160ms), 200ms(200ms), 500ms(500ms), 1000ms(1000ms), 1500ms(1500ms) 0ms, 80ms, 120ms, 160ms, 200ms, 500ms, 1000ms, 1500ms ms None 500ms Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
T3212 T3212 BSC6900 SET GCELLIDLEBASIC(Optional) This parameter specifies the length of the timer for periodic location update. GBFD-110301Location Updating Interval Type 0~255 0~255, step: 6 min None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved It is recommended that you select a greater value, such as 16, 20, or 25, in the area with heavy traffic, but a smaller value, such as 2 or 3, in the area with light traffic. To properly specify the value of this parameter, it is necessary to perform overall and long-term measurement on the entities involved regarding their processing capability and traffic, such as the processing capability of the MSC and BSC, and the load on the A interface, Abis interface, Um interface, HLR, and VLR.The location update period in the MSC must be greater than that in the BSC.In the GSM system, it is possible that a powered-on MS is identified as implicit off-line if the MS sends no location update request within a long period.When the MS reselects another cell (in the same LAC), the MS is restarted through T3212 timeout if the T3212 of the new cell differs from that of the original cell.When this parameter differs in the cells of the same LAC, it is possible that the MS is identified as implicit off-line if the MS send
T391 Parameter of DTE [T391] BSC6900 ADD BC(Optional) Timer on the DTE side, specifying the duration of acknowledging the sending link integrity. GBFD-510002Gb Over FR Interval Type 5~30 5~30 s 10 10 BC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
T3TMR Time-control changeback timer BSC6900 SET MTP3TMR(Optional) When a normal changeback cannot be initiated, services will be changed back to a normal link only after this timer expires to avoid disorder of data. None None Interval Type 800~1200 800~1200 ms None None MTP3 linkNone Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
T4 T4 BSC6900 SET BSSGPPARA(Optional) Timer T4. T3 is started after the message v is received on the BSC side. T4 is stopped after the message RESUME ACK is received. GBFD-119001Gb Interface Function Interval Type 1000~10000 1000~10000 ms None 5000 BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
T4TMR Changeover ACK first attempt timer BSC6900 SET MTP3TMR(Optional) This timer is a protection timer waiting for a changeback acknowledgement message (CBA) from the peer end after the first changeback declaration (CBD) is sent to the peer end. None None Interval Type 800~1200 800~1200 ms None None MTP3 linkNone Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
T5 T5 BSC6900 SET BSSGPPARA(Optional) Timer T5. When the downlink TBF is set up, if the BSC side does not receive the valid recap, the BSC originates the radio access capability update flow and the timer T5 is started. After receiving the core network response, the timer is stopped. GBFD-119001Gb Interface Function Interval Type 1000~30000 1000~30000 ms None 1000 BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
T5TMR Changeover ACK second attempt timer BSC6900 SET MTP3TMR(Optional) This timer is a protection timer waiting for a changeback acknowledgement message (CBA) from the peer end after the second changeback declaration (CBD) is sent to the peer end. None None Interval Type 800~1200 800~1200 ms None None MTP3 linkNone Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
T6 T6 BSC6900 SET BSSGPPARA(Optional) Timer T6. The BSC sends the SGSN request to download the BSS PFC. When the QoS parameter is obtained, the timer is started. After the message CREATE_BSS_PFC is received, the timer is stopped. After the timer expires, the request is sent to start the procedure of downloading the BSS PFC. GBFD-119001Gb Interface Function Interval Type 1000~10000 1000~10000 ms None 3000 BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
T8 T8 BSC6900 SET BSSGPPARA(Optional) Timer T8. The BSC sends the SGSN request to download the BSS PFC. When the QoS parameter is obtained, the timer is started. After the message MODIFY-BSS-PFC-ACK is received, the timer is stopped. After the timer expires, the request is sent to start the procedure of downloading the BSS PFC. GBFD-119001Gb Interface Function Interval Type 1000~10000 1000~10000 ms None 3000 BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
T8TMR Transmission prohibited inhibition timer BSC6900 SET MTP3TMR(Optional) This timer is started when a transmission prohibited message (TFP) is sent. The TFP will not be sent any more during the running of this timer. None None Interval Type 800~1200 800~1200 ms None None MTP3 linkNone Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TAFLTLEN Filter Length for TA BSC6900 SET GCELLHOFITPEN(Optional) When the network receives measurement reports, the measurement values in several straight measurement reports are filtered to reflect the radio operating environment for the sake of accuracy. This parameter specifies the number of measurement reports sampled for filtering the TA. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 1~31 1~31, step:480 for TCH and 470 for SDCCH ms None 4 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TAFORUOHOALLOW TA for UO HO Allowed BSC6900 SET GCELLHOIUO(Optional) Whether the TA is used as a decisive condition for the concentric cell handover. GBFD-113201Concentric Cell Enumeration Type NO(No), YES(Yes)NO, YES None None NO Cell This parameter is valid only when "IUOTP" in "ADD GCELL" is set to Concentric_cell. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TAHOEN TA HO Allowed BSC6900 SET GCELLHOBASIC(Optional) Whether to enable the time advance (TA) handover. The TA handover determines whether the timing advance (TA) is higher than the predefined TA threshold. When the TA is higher than the predefined TA threshold, a TA handover is triggered. The TA is calculated based on the distance between the MS and the BTS. The longer the distance is, the greater the TA value is. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Enumeration Type NO(No), YES(Yes)NO, YES None None YES Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TAHYST TA Hysteresis BSC6900 SET GCELLHOIUO(Optional) One of the parameters that determine the coverage of the OL subcell and UL subcell.When "Enhanced Concentric Allowed" is set to NO, "TA Hysteresis", "RX_LEV Threshold", "RX_LEV Hysteresis", "RX_QUAL Threshold", and "TA Threshold" determine the coverage of the OL subcell and UL subcell.When "Enhanced Concentric Allowed" is set to YES, "TA Hysteresis", "UtoO HO Received Level Threshold", "OtoU HO Received Level Threshold", "RX_QUAL Threshold", and "TA Threshold" determine the coverage of the OL subcell and UL subcell. GBFD-113201Concentric Cell Interval Type 0~255 0~255 bit None 0 Cell This parameter is valid only when "IUOTP" in "ADD GCELL" is set to Concentric_cell. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TALASTTIME TA HO valid time BSC6900 SET GCELLHOBASIC(Optional) The P/N criterion must be met for triggering a TA handover. That is, the TA handover can be triggered only if P measurement reports among N measurement reports meet the triggering conditions. This parameter corresponds to P in the P/N criterion. GBFD-510501HUAWEI II Handover Interval Type 1~16 1~16, step:0.5 s None 1 Cell This parameter is valid only when "HOCTRLSWITCH" is set to HOALGORITHM2 and "TAHOEN" is set to YES. The following condition must be met: "TASTATTIME" >= "TALASTTIME". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TALIMIT TA Threshold BSC6900 SET GCELLHOEMG(Optional) An emergency handover is triggered when TA is greater than or equal to the value of this parameter. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 0~255 0~255 bit None 255 Cell This parameter is valid only when "TAHOEN" in "SET GCELLHOBASIC" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TALKERINFINT Talker Info Interval BSC6900 SET GCELLGSMR(Optional) This parameter specifies the interval of broadcasting the speech data of the talker on the downlink group call channel that is controlled by the BTS. When the parameter is set to 0, the BTS (instead of the BSC) performs the broadcasting with the default interval 5s. GBFD-510306Talker Identification Interval Type 0~255 0~255 s None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TASIGSTRFLTLEN TA filter length for SDCCH level BSC6900 SET GCELLHOFITPEN(Optional) When the network receives measurement reports, the measurement values in several straight measurement reports are filtered to reflect the radio operating environment for the sake of accuracy. This parameter specifies the number of measurement reports sampled for filtering the TA on the signaling channel. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 1~31 1~31, step:480 for TCH and 470 for SDCCH ms None 2 Cell This parameter is valid only when "HOCTRLSWITCH" in "SET GCELLHOBASIC" is set to HOALGORITHM2. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TASKID TaskID BSC6900 SET LOGCFG(Mandatory) TaskID MRFD-210304Faulty Management Interval Type 0~65535 {0~65535} None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TASKIDX Aiss Task Index BSC6900 ADD AISSCFG(Mandatory)ADD NCELL(Mandatory)COL SYNCINFO(Mandatory)SET BTSEXCURSION(Mandatory)SET BSCSYNCOFF(Mandatory)COL BSCSYNCINFO(Mandatory) Unique identifier of the Um interface software synchronization task. GBFD-118201Soft-Synchronized Network Interval Type 0~7 0~7 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None.
TASTATTIME TA HO watch time BSC6900 SET GCELLHOBASIC(Optional) The P/N criterion must be met for triggering a TA handover. That is, the TA handover can be triggered only if P measurement reports among N measurement reports meet the triggering conditions. This parameter corresponds to N in the P/N criterion. GBFD-510501HUAWEI II Handover Interval Type 0~16 0~16, step:0.5 s None 1 Cell This parameter is valid only when "TAHOEN" is set to YES and "HOCTRLSWITCH" is set to HOALGORITHM2. The following condition must be met: "TASTATTIME" >= "TALASTTIME". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TATHRES TA Threshold BSC6900 SET GCELLHOIUO(Optional) One of the parameters that determine the coverage of the OL subcell and UL subcell.When "Enhanced Concentric Allowed" is set to NO, "TA Hysteresis", "RX_LEV Threshold", "RX_LEV Hysteresis", "RX_QUAL Threshold", and "TA Threshold" determine the coverage of the OL subcell and UL subcell.When "Enhanced Concentric Allowed" is set to YES, "TA Hysteresis", "UtoO HO Received Level Threshold", "OtoU HO Received Level Threshold", "RX_QUAL Threshold", and "TA Threshold" determine the coverage of the OL subcell and UL subcell. GBFD-113201Concentric Cell Interval Type 0~255 0~255 bit None 63 Cell This parameter is valid only when "IUOTP" in "ADD GCELL" is set to Concentric_cell. The following condition must be met: "TALIMIT" > "TATHRES". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TAVGT T_AVG_T BSC6900 SET GCELLPSPWPARA(Optional) Filter period of the signal strength in the packet transmission mode of the MS. In the packet transmission mode, the signal level filter parameter of the filter period of the signal strength for power control in the packet transmission mode. The MS in the packet transmission mode measures the downlink signal strength. This parameter is used to calculate the Cn value of the MS output power. This parameter specifies the relation between Cn and Cn-1. GBFD-119115Power Control Interval Type 0~25 0~25 None None 10 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TAVGW T_AVG_W BSC6900 SET GCELLPSPWPARA(Optional) Filter period of the signal strength in the packet idle mode of the MS. In the packet idle mode, the signal level filter parameter of the filter period of the signal strength for power control in the packet idle mode. The MS in the packet idle mode measures the downlink signal strength. This parameter is used to calculate the Cn value of the MS output power. This parameter specifies the relation between Cn and Cn-1. GBFD-119115Power Control Interval Type 0~25 0~25 None None 10 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TB Output Segment No. BSC6900 EXP DEVFILE(Optional) Number of the output segment1: Segment 1 describes the basic information of the equipment.2: Segment 2 describes the connection information.3: Segment 3 describes the module information.4: Segment 4 describes the configuration information.5: Segment 5 describes the information of the peer equipment.6: Segment 6 describes the version information of the host.7: Segment 7 describes the cabinet information.8: Segment 8 describes the subrack information.9: Segment 9 describes the board information and electronic label information of the Flash.10: Segment 10 describes the slot information.11: Segment 11 describes the port information.12: Segment 12 describes the antenna information. GBFD-111203O&M of BSC Interval Type 1~12 1~12 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None.
TB Output Segment No. BSC6900 EXP BTSDEVFILE(Optional) Output Segment No.1: Segment 1 describes the basic information of the equipment.2: Segment 2 describes the connection information.3: Segment 3 describes the module information.4: Segment 4 describes the configuration information.5: Segment 5 describes the information of the peer equipment.6: Segment 6 describes the version information of the host.7: Segment 7 describes the cabinet information.8: Segment 8 describes the subrack information.9: Segment 9 describes the board information and electronic label information of the Flash.10: Segment 10 describes the slot information.11: Segment 11 describes the port information.12: Segment 12 describes the antenna information. GBFD-111202O&M of BTS Interval Type 1~12 1~12 None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TBFQueuingSwitch TBF Queuing Switch BSC6900 SET GCELLPSOTHERPARA(Optional) Whether the TBF queuing is supported. When this parameter is set to ON, the TBF queuing function is supported and no Assignment Reject message is sent. When this parameter is set to OFF and there is no channel resource, an Immediate Assignment Reject message is sent. GBFD-114101GPRS Enumeration Type OFF(OFF), ON(ON) OFF, ON None None OFF Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TBS Try switching duration time BSC6900 SET BTSOMLBACKUP(Optional) Maximum time in which the BTS attempts to set up the OML before swapping the main and backup OMLs. If the BTS fails to set up the OML within this time, the BTS swaps the main and backup OMLs. GBFD-113728OML Backup Interval Type 30~300 30~300 s None 90 BTS This parameter is valid only when "OMLBKUP" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TBS Ring I Try Rotating Duration Time BSC6900 SET BTSRINGATTR(Optional) The BTS repeatedly attempts to connect to port 0 or port 1 after the switchover. If the connection on one port fails within the time specified by this parameter, the BTS tries to connect to another port. GBFD-117801Ring Topology Interval Type 60~300 60~300 s None None BTS This parameter must meet the following requirements: "FallBack Start Time" > "Ring I Wait Time Before Switch" + "Ring I Try Rotating Duration Time". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TC Test code BSC6900 ADD MTP3LNK(Optional) Test code for the MTP3 link. After the successful test, the link can be used for carrying signaling services. If the test fails, the MTP3 periodically sends the fault locating command until the operation is successful. When the link is deleted or deactivated, the system stops to send the fault locating command. The default value is 170. None None Interval Type 1~254 1~254 None 170 170 MTP3 linkNone Read & Write Y BSC6900 Less than 5 minutes None
TC Tc BSC6900 SET BSSGPPARA(Optional) Timer Tc, specifying the interval for the BVC and MS to send flow control messages. When this parameter is set to a smaller value, the BVC and the MS send flow control messages in a shorter time, which allows the SGSN can use the latest flow control parameter to improve the transmission performance. When the BVC and MS send flow control messages, certain bandwidth is required. If this parameter is set to a too small value, the transmission performance is reduced. If this parameter is set to a greater value, the realtime flow control mechanism of the Gb interface cannot handle the current situation properly. This can reduce the transmission performance and provide more bandwidth. GBFD-119001Gb Interface Function Interval Type 1000~10000 1000~10000 ms None 4000 BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TCC Temperature Compensation Coefficient BSC6900 SET BTSAPMUBP(Optional) Temperature compensation coefficient. This parameter defines the charging voltage increase or decrease unit of each battery when the ambient temperature of the battery varies with the reference temperature regulated by the vendor by 1 degree Celsius. See the vendor specification for the setting of this parameter.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. GBFD-111202O&M of BTS Interval Type 0~500 0~500 mV None 80 BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TCCRCAllowed TC CRC Allowed BSC6900 SET BSCBASIC(Optional) This parameter specifies the cyclic redundancy check (CRC) switch, which can be set to On or Off. The value of this parameter determines whether check is performed on the TRAU frame between the BSC and the BTS. GBFD-111203O&M of BSC Enumeration Type OFF(Off), ON(On) OFF, ON None ON ON BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved According to the GSM protocols, the BSC performs CRC on each TRAU frame. If the CRC of a certain TRAU frame fails, the TRAU frame is regarded as an invalid one. Then, the BSC performs smoothing on the invalid frame, thus eliminating the noise caused by the errors in parameter transmission. The CRC should be performed on the TRAU frames of all speech services except the FR service.
TCHAJFLAG TCH Rate Adjust Allow BSC6900 SET GTRXDEV(Optional) Whether to allow the cell to change a channel from full rate to half rate or from half rate to full rate dynamically. If this parameter is set to NO, each channel that has been adjusted is restored to the set rate mode. In addition, this parameter helps to determine the channel assignment priority. The channels in a TRX that does not allow dynamic adjustment are assigned before the channels in a TRX that allows dynamic adjustment. GBFD-113402Dynamic Adjustment Between FR and HR Enumeration Type NO(No), YES(Yes)NO, YES None None None TRX None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TCHBUSYTHRES TCH Traffic Busy Threshold BSC6900 SET GCELLCHMGAD(Optional) If the current channel seizure ratio reaches or exceeds this value, the half-rate TCH is assigned preferentially; otherwise, the full-rate TCH is assigned preferentially. GBFD-111005Enhanced Channel Assignment Algorithm Interval Type 0~100 0~100 per cent None 60 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TCHDROPSTATDLFER DL FER Threshold for TCH Call Drop BSC6900 SET GCELLOTHEXT(Optional) When a call drops on the TCH, the corresponding TCH call drop counter is incremented by one if the DL FER carried in the last MR is greater than the value of this parameter. GBFD-111004Radio Dedicated Channel Management Interval Type 0~1000 0~1000 per millNone 40 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TCHDROPSTATDLLEV DL Level Threshold for TCH Call Drop BSC6900 SET GCELLOTHEXT(Optional) When a call drops on the TCH, the corresponding TCH call drop counter is incremented by one if the downlink level carried in the last MR is lower than the value of this parameter. GBFD-111004Radio Dedicated Channel Management Interval Type 0~63 0~63 dB None 6 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TCHDROPSTATDLQUAL DL Quality Threshold for TCH Call Drop BSC6900 SET GCELLOTHEXT(Optional) When a call drops on the TCH, the corresponding TCH call drop counter is incremented by one if the downlink quality carried in the last MR is greater than the value of this parameter. GBFD-111004Radio Dedicated Channel Management Interval Type 0~70 0~70 None None 55 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TCHDROPSTATULFER UL FER Threshold for TCH Call Drop BSC6900 SET GCELLOTHEXT(Optional) When a call drops on the TCH, the corresponding TCH call drop counter is incremented by one if the UL FER carried in the last MR is greater than the value of this parameter. GBFD-111004Radio Dedicated Channel Management Interval Type 0~1000 0~1000 per millNone 40 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TCHDROPSTATULLEV UL Level Threshold for TCH Call Drop BSC6900 SET GCELLOTHEXT(Optional) When a call drops on the TCH, the corresponding TCH call drop counter is incremented by one if the uplink level carried in the last MR is lower than the value of this parameter. GBFD-111004Radio Dedicated Channel Management Interval Type 0~63 0~63 dB None 6 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TCHDROPSTATULQUAL UL Quality Threshold for TCH Call Drop BSC6900 SET GCELLOTHEXT(Optional) When a call drops on the TCH, the corresponding TCH call drop counter is incremented by one if the uplink quality carried in the last MR is greater than the value of this parameter. GBFD-111004Radio Dedicated Channel Management Interval Type 0~70 0~70 None None 55 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TCHHOMININTV Min Interval for TCH Hos BSC6900 SET GCELLHOCTRL(Optional) After a new TCH is assigned to an MS, the MS can be handed over to another channel only if the time during which the MS occupies the TCH is longer than the period specified by this parameter. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 0~60 0~60 s None 2 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TCHMRCUTNUM TchMrCutNum BSC6900 SET GCELLPWR3(Optional) Maximum number of discarded MRs allowed on the TCH in a power control period. GBFD-117601HUAWEI III Power Control Algorithm Interval Type 0~10 0~10 None None 3 Cell This parameter is valid only when "PWRCTRLSW" in "SET GCELLPWRBASIC" is set to PWR3. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TCHRATEMODIFY TCH Rate Modify BSC6900 SET OTHSOFTPARA(Optional) Whether the TCH rate type uses the MSC strategy or BSC strategy. When this parameter is set to NO and the MSC policy is used, the BSC preferentially selects full-rate or half-rate channels based on the rate type carried by the MSC in the assignment or incoming BSC handover request. When this parameter is set to YES and the BSC policy is used, the BSC preferentially the full-rate or half-rate channels based on the internal load. GBFD-111005Enhanced Channel Assignment Algorithm Enumeration Type NO(No), YES(Yes)NO, YES None None YES BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TCHTIMEHOPERIOD TCH Time Handover Period BSC6900 SET GCELLSOFT(Optional) This parameter specifies the interval at which the speech service on a TCH is handed over. GBFD-113521Encrypted Network Management Interval Type 1~600 1~600 s None 60 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TCHTIMEHOSWITCH TCH Time Handover Switch BSC6900 SET GCELLSOFT(Optional) This parameter specifies whether to perform periodic intra-cell handover for speech services on TCH. GBFD-113521Encrypted Network Management Enumeration Type OFF(Off), ON(On) OFF, ON None None OFF Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TCHTRIBUSYUNDERLAYTHR Tch Traffic Busy Underlay Threshold BSC6900 SET GCELLCHMGAD(Optional) Threshold for determining that the underlaid subcell is busy. The BSC assigns channels in the underlaid subcell to the MS in a concentric cell. When "Allow Rate Selection Based on Overlaid/Underlaid Subcell Load" is set to YES, half-rate channels are assigned if the channel seizure ratio in the underlaid subcell exceeds the value of this parameter, and full-rate channels are assigned if the channel seizure ratio in the underlaid subcell does not exceed the value of this parameter. GBFD-113201Concentric Cell Interval Type 0~100 0~100 per cent None 60 Cell "TCHTRICBUSYOVERLAYTHR" and "TCHTRIBUSYUNDERLAYTHR" can be set only when "HRIUOLDRATESELALLOW" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TCHTRICBUSYOVERLAYTHR Tch Traffic Busy Overlay Threshold BSC6900 SET GCELLCHMGAD(Optional) The BSC assigns channels in the overlaid subcell to the MS in a concentric cell. If the channel seizure ratio of overlaid subcell is greater than the value of this parameter, half-rate channels are assigned. Otherwise, full-rate channels are assigned. Channel seizure ratio = (Num. of busy TCHF + Num. of busy TCHH/2)/(Num. of available TCHF + Num. of available TCHH /2) x 100%. This parameter is valid for the concentric cell. When the "Allow Rate Selection Based on Overlaid/Underlaid Subcell Load" is set to Yes, the "TCH Traffic Busy Threshold (%)" is invalid for the concentric cell. GBFD-113201Concentric Cell Interval Type 0~100 0~100 per cent None 70 Cell "TCHTRICBUSYOVERLAYTHR" and "TCHTRIBUSYUNDERLAYTHR" can be set only when "HRIUOLDRATESELALLOW" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TCLEN Test code length BSC6900 ADD MTP3LNK(Optional) Test code length of the signaling link. By default, the value is 10. None None Interval Type 1~15 1~15 None 10 10 MTP3 linkNone Read & Write Y BSC6900 Less than 5 minutes None
TCMODE TC mode BSC6900 ADD MTP3LNK(Mandatory) To specify the mode of TC. None None Enumeration Type SEPERATE_PRINCIPAL(Principal BSC), SEPERATE_SUBORDINATE(Subordinate BSC), TOGETHER(BSC/TC Together) SEPERATE_PRINCIPAL, SEPERATE_SUBORDINATE, TOGETHER None None None MTP3 linkNone Read & Write Not involved Not involved Not involved The parameter cannot be modified.
TCMUTEDETECTFLAG TC Mute Detect Flag BSC6900 SET GCELLSOFT(Optional) Whether to permit the TC mute detection GBFD-111203O&M of BSC Enumeration Type NO(No), YES(Yes)NO, YES None None NO Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TCN Tail Cabinet No. BSC6900 ADD BTSRXUCHAIN(Mandatory)CBN BTSRXUCHAIN(Mandatory) Number of the cabinet where the tail board of the RXU ring is located GBFD-111202O&M of BTS Interval Type 0~62 0~62 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TCPN TC Port No BSC6900 ADD ATERCONPATH(Mandatory) TC port No. where one end of the ATER connection channel is located None None Interval Type 0~335 0~335 None None None Control plane link None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
TCPOOLID TC Pool ID BSC6900 SET BSCBASIC(Mandatory) If you enable the TC pool function when configuring the basic information of the BSC, you need to enter the TC Pool ID. The ID must be unique in the entire network. GBFD-113726TC Pool Interval Type 0~4095 0~4095 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TCSN TC Slot No BSC6900 ADD ATERCONPATH(Mandatory) TC slot No. where one end of the ATER connection channel is located None None Interval Type 0~5,8~27 0~5, 8~27 None None None Control plane link None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
TCSRN TC Subrack No BSC6900 ADD ATERCONPATH(Mandatory) TC subrack No. where one end of the ATER connection channel is located None None Interval Type 0~11 0~11 None None None Control plane link None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
TDDBA1TAG TDD BA1 Input Tag BSC6900 SET GCELLIDLETDDBA1(Mandatory) Input mode of the BA table. In auto mode, the system fills in the BA1 and BA2 tables based on the adjacent relation of cells. In manual mode, the user maintains the BA table. If the adjacent relation of cells is modified, for example, a neighboring cell is added or a cell is deleted, the user needs to maintain the BA1 and BA2 tables. GBFD-114302GSM/TD-SCDMA Interoperability Enumeration Type AUTO(Auto), Manual(Manual) AUTO, Manual None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TDDBA2TAG TDDBA2 input tag BSC6900 SET GCELLHOTDDBA2(Mandatory) Whether the FDD BA2 table is generated automatically according to the neighboring relation or typed manually. MRFD-210301Configuration Management Enumeration Type AUTO(Auto), Manual(Manual) AUTO, Manual None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TDDCELLOFF TDD Reporting Offset BSC6900 SET GCELLCCUTRANSYS(Optional) When the priority of a TDD cell is ranked, the value of this parameter is added to the receive level of the TDD cell in the measurement report. GBFD-114302GSM/TD-SCDMA Interoperability Interval Type 0~7 0~7, step:6 dB None 0 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TDDCELLRESELDIV TDD Cell Reselect Diversity BSC6900 SET GCELLCCUTRANSYS(Optional) A TDD cell can become a candidate cell only when the average receive level of the TDD cell is greater than the TDD Cell Reselect Diversity of the serving cell.The value of this parameter corresponds to the following decibel value:0: -1: -28 dB2: -24 dB... 15: 28 dB GBFD-114302GSM/TD-SCDMA Interoperability Interval Type 0~15 0~15, step:4 dB None 8 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TDDCELLTHRED TDD Reporting Threshold BSC6900 SET GCELLCCUTRANSYS(Optional) Threshold for determining whether the MR about a TDD cell is valid.The measurement report is valid if the receive level of the TDD cell in the measurement report is greater than the value of this parameter. After the valid measurement report is filtered, the TDD cell joins in the cell prioritization.The value of this parameter corresponds to the following decibel value:0: 0 dB1: 6 dB...6: 36 dB7: - GBFD-114302GSM/TD-SCDMA Interoperability Interval Type 0~7 0~7, step:6 dB None 0 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TDDDIVERSITY Diversity BSC6900 SET GCELLIDLETDDBA1(Mandatory) This parameter specifies whether to activate the diversity mode on the common channel of a 3G cell. GBFD-114302GSM/TD-SCDMA Interoperability Interval Type 0~1 0~1 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TDDDLUARFAN DL UARFAN BSC6900 SET GCELLIDLETDDBA1(Mandatory) Downlink frequency of frequency 1 in table 3GBA2. This parameter indicates the detected downlink frequency in the 3G adjacent cell list in speech. The parameter is delivered in the system information 2QUTER/MI. GBFD-114302GSM/TD-SCDMA Interoperability Interval Type 0~16383 0~16383 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TDDMIOPTIMIZEDALLOWED TDD MI System Information Optimized BSC6900 SET GCELLCCUTRANSYS(Optional) This parameter specifies whether the TDD MI system information optimized function is enabled. GBFD-114302GSM/TD-SCDMA Interoperability Enumeration Type NO(No), YES(Yes)NO, YES None None NO Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved Before switched on, please insure that all the TRXs in this cell are suitable version.
TDDMIPROHIBIT TDD MI System INFO Broadcasting Prohibit BSC6900 SET GCELLCCUTRANSYS(Optional) This parameter determines whether the broadcasting of the MI system information is prohibited. GBFD-114302GSM/TD-SCDMA Interoperability Enumeration Type NO(No), YES(Yes)NO, YES None None NO Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TDDRSCPQUALTHRSH PS TDD RSCP Quality Threshold BSC6900 ADD GEXT3GCELL(Optional) Minimum RSCP quality threshold that the TDD 3G candidate cell must reach. GBFD-114302GSM/TD-SCDMA Interoperability Interval Type 0~63 0~63 None None 10 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TDDSCRAMBLE Cell Parameter ID BSC6900 SET GCELLIDLETDDBA1(Mandatory) TDD cell parameter ID. The ID is used to distinguish terminals or cells. This parameter is used after spread spectrum. Therefore, it does not change the bandwidth of signals, but only distinguishes the signals from different sources. Through scrambling, multiple transceivers can use the same codes for spread spectrum. GBFD-114302GSM/TD-SCDMA Interoperability Interval Type 0~127 0~127 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TDDSCRAMBLE Cell parameter ID BSC6900 SET GCELLHOTDDBA2(Mandatory) Cell parameter ID of a TDD cell. The cell parameter ID distinguishes between MSs or cells. It is used after spread spectrum. Therefore, it distinguishes between the signals from different sources, but not changes the bandwidth of signals. Through scrambling, multiple transceivers can use the same codes for spread spectrum. MRFD-210301Configuration Management Interval Type 0~127 0~127 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TDDSIOPTIMIZEDALLOWED TDD System Information Optimized Allowed BSC6900 SET GCELLCCUTRANSYS(Optional) This parameter determines whether the TDD system information optimized function is enabled. GBFD-114302GSM/TD-SCDMA Interoperability Enumeration Type NO(No), YES(Yes)NO, YES None None NO Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TDDSYNCCASE Sync Case BSC6900 SET GCELLIDLETDDBA1(Mandatory)SET GCELLHOTDDBA2(Mandatory) SyncCase in the TDDBA1 table. This parameter determines the synchronization status. Value 0 indicates Sync case 1 and value 1 indicates Sync case 2. This parameter is used to identify different 3G cells. GBFD-114302GSM/TD-SCDMA Interoperability Interval Type 0~1 0~1 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TDMCONGCLRTH Congestion clear remain ratio BSC6900 ADD TRMLOADTH(Optional) Congestion clear remain ratio None None Interval Type 0~100 0~100 per cent 20 20 None None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
TDMCONGTH Congestion remain ratio BSC6900 ADD TRMLOADTH(Optional) Congestion remain ratio. None None Interval Type 0~100 0~100 per cent 15 15 None None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
TDMN1 Subrack 1 TDM Port No BSC6900 ADD SRCONPATH(Mandatory) Each subrack has six TDM numbers, ranging from 0 to 5. Subrack 1 TDM Port No. refers to the TDM number on subrack 1 of the inter-subrack connection.. GBFD-111203O&M of BSC Interval Type 0~5 0~5 None None None Control plane link None Read & Write Y Subrack connection path Less than 5 minutes 1. The command is used for the configuration when the TDM resources exist between two subracks.2. Each subrack must be the BM subrack or TC subrack.
TDMN2 Subrack 2 TDM Port No BSC6900 ADD SRCONPATH(Mandatory) Each subrack has six TDM numbers, ranging from 0 to 5. Subrack 2 TDM Port No. refers to the TDM number on subrack 2 of the inter-subrack connection. GBFD-111203O&M of BSC Interval Type 0~5 0~5 None None None Control plane link None Read & Write Y Subrack connection path Less than 5 minutes 1. The command is used for the configuration when the TDM resources exist between two subracks.2. Each subrack must be the BM subrack or TC subrack.
TEI TEI BSC6900 ADD PBSL(Optional) Terminal endpoint ID of the Pb signaling link. GBFD-111203O&M of BSC Interval Type 0~127 0~127 None 63 63 PBSL None Read & Write Y BSC6900 The services are interrupted until the PBSL is working normally. None
TEMP_MASK Enable Temperature Alarm Reporting BSC6900 ADD EMU(Optional) Temperature alarm switch MRFD-210304Faulty Management Enumeration Type CLOSE(Close), OPEN(Open) CLOSE, OPEN None OPEN None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TEMP_THD_HIGH Upper Limit of Temperature Alarm BSC6900 ADD EMU(Optional) Upper limit of temperature MRFD-210304Faulty Management String Type None 1~9 characters degree Celsius 45 None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TEMP_THD_LOW Lower Limit of Temperature Alarm BSC6900 ADD EMU(Optional) Lower limit of temperature MRFD-210304Faulty Management String Type None 1~9 characters degree Celsius 0 None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TEMPALARMTHRESHOLDH Upper ENV TEMP Alarm BSC6900 SET BTSAPMUBP(Optional) When the environment temperature of the APMU is greater than the value of this parameter, the BTS reports an alarm. For the APMU of the non-APM4815 type, the minimum value of the parameter is -490.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. MRFD-210304Faulty Management Interval Type -500~1000 -50~100 (step: 0.1) degree Celsius None 500 BTS This parameter must be at least 3C greater than "Lower ENV TEMP Alarm". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
5/5/2014
Confidential Information of Huawei.
No Spreading without Permission
Page19of42
226347869.xls.ms_office Security Level:
TEMPALARMTHRESHOLDH Upper ENV TEMP Alarm BSC6900 SET BTSDPMUBP(Optional) When the environment temperature is greater than the value of this parameter, the BTS reports an alarm.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. MRFD-210304Faulty Management Interval Type -490~1000 -49.0~100.0 (step: 0.1) degree Celsius None 500 BTS This parameter must be at least 4C greater than "Lower ENV TEMP Alarm". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TEMPALARMTHRESHOLDL Lower ENV TEMP Alarm BSC6900 SET BTSAPMUBP(Optional) When the environment temperature of the APMU is less than the value of this parameter, the BTS reports an alarm. For the APMU of the non-APM4815 type, the maximum value of the parameter is 990.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. MRFD-210304Faulty Management Interval Type -500~1000 -50~100 (step: 0.1) degree Celsius None If "APMU Board Type" is "APM200E", the recommended value is "-100". For other types of APMU boards, the recommended value is "0". BTS This parameter must be at least 3C lower than "Upper ENV TEMP Alarm". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TEMPALARMTHRESHOLDL Lower ENV TEMP Alarm BSC6900 SET BTSDPMUBP(Optional) When the environment temperature is less than the value of this parameter, the BTS reports an alarm.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. MRFD-210304Faulty Management Interval Type -500~990 -50.0~99.0 (step: 0.1) degree Celsius None 0 BTS This parameter must be at least 4C lower than "Upper ENV TEMP Alarm". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TEMPCOMPENSATECOEF Coefficient of tempCompensation BSC6900 SET BTSDPMUBP(Optional) Change value of the floating charge voltage of the storage battery when the temperature of the storage battery changes by 1 degree Celsius. GBFD-111202O&M of BTS Interval Type 0~5000 0~500 (step: 0.1) mV None 800 BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TEMPLATEDESC Cell Template Description BSC6900 SAV GCELLTEMPLATE(Optional) Description of a cell template. MRFD-210301Configuration Management String Type None 1~64 characters None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TEMPLATEID Cell Template Index BSC6900 EXP GCELLTEMPLATE(Mandatory) This parameter specifies the index number of a cell template. Each template is numbered uniquely in a BSC. None None Interval Type 1~65535 1~65535 None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TEMPLATEID Cell Template Index BSC6900 SAV GCELLTEMPLATE(Optional) This parameter specifies the index number of a cell template. Each template is numbered uniquely in a BSC. None None Interval Type 32768~65535 32768~65535 None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TEMPLATENAME Cell Template Name BSC6900 ADD GCELL(Optional)ADD GCELLQUICKSETUP(Optional)ADD BTSAUTOPLAN(Optional)EXP GCELLTEMPLATE(Mandatory)SAV GCELLTEMPLATE(Mandatory) Name of a cell template, uniquely identifying a cell template in a BSC. None None String Type None 1~64 characters None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TEMPOFHIGHTEMPLOADPWROFF Temp Of High Temp Load Pwr Off BSC6900 SET BTSAPMUBP(Optional) When the temperature of the BTS cabinet is greater than the value of this parameter, the TRX is powered off. GBFD-111202O&M of BTS Interval Type 50~70 50~70 degree Celsius None 65 BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TEMPOFLOWTEMPLOADPWROFF Lowtemp start load poweroff temp BSC6900 SET BTSAPMUBP(Optional) TRX power-off temperature threshold. If the temperature of the BTS cabinet is less than the value of this parameter while "Low Temperature Startup Allowed" is set to "Yes", the TRX is powered off. GBFD-111202O&M of BTS Interval Type -400~0 -40~0 (step: 0.1) degree Celsius None For APM4815 boards, the value of this parameter is always "-1". For other types of APMU boards, the recommended value is "-100". BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TEMPOFLOWTEMPLOADPWROFF LowTemp Start Load Poweroff Temp BSC6900 SET BTSDPMUBP(Optional) TRX power-off temperature threshold. If the temperature of the BTS cabinet is less than the value of this parameter while "Low Temperature Startup Allowed" is set to "Yes", the TRX is powered off.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. GBFD-111202O&M of BTS Interval Type -400~0 -40.0~0.0 (step: 0.1) degree Celsius None -100 BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TER2INDICATOR TER Indicator of System Information 3 BSC6900 SET OTHSOFTPARA(Optional) Whether the System Information Type 3 message carries TER indication. GBFD-111101System Information Sending Enumeration Type NO(No), YES(Yes)NO, YES None None YES BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TESTTIMER Test Timer BSC6900 SET BSCNSPARA(Optional) Duration of the timer for starting the IP path status test on the Gb interface. GBFD-119001Gb Interface Function Interval Type 1~255 1~255 s None 30 BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TEXT Content of message BSC6900 ADD GSMSCB(Mandatory) Content of the cell broadcast message GBFD-113602Simplified Cell Broadcast Any Type None 1~2462 characters None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TFOOptSwitch TFO Option Switch BSC6900 SET TCPARA(Optional) AEC is an important measure to improve the speech quality. If the AEC works for a consecutive time that is longer than the value of this parameter, the TFO function is closed to provide a better speech quality. GBFD-115701TFO Enumeration Type OFF(Off), ON(On) OFF, ON None None OFF Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TFREQ Test Frequency BSC6900 STR BTSVSWRTST(Optional) In the VSWR test, the TRX transmits signals at a default frequency. You can specify the frequency used for the test. GBFD-111207BTS Test Function Interval Type 0~1023 0~1023 h None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TFRMSTARTTIME Frame Start Time BSC6900 SET GCELLOTHEXT(Optional) This parameter indicates start frame number of the BTS. It is used to keep synchronization between the BTS and MS after the BTS is re-initialized. MRFD-210301Configuration Management Interval Type 0~65535 0~65535 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved For the BTS3001C, BTS3001CP, and BTS3002C, this parameter is invalid. For other BTSs, this parameter is valid.
TG Target OMU BSC6900 SWP OMUAREA(Mandatory) Target OMU GBFD-111203O&M of BSC Enumeration Type ACTIVE(Active OMU), STANDBY(Standby OMU) ACTIVE(Active OMU), STANDBY(Standby OMU) None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TGWID TGW ID BSC6900 ADD TGWIP(Mandatory) TGW ID. None None Interval Type 0~255 0~255 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TGWIPOAMIP NodeB IP_TRANS IP address BSC6900 ADD TGWIP(Mandatory) This parameter indicates the address of the operation and maintenance console for TGW. None None IP Address Type None 0.0.0.0~255.255.255.255 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The IP address of the TGW cannot use the configured IP address of another TGW . The IP address of TGW cannot be the same as the IP address configured in the BSC. Otherwise, operation and maintenance channel for TGW fails.
TGWIPOAMMASK TGW IP_TRANS IP Mask BSC6900 ADD TGWIP(Mandatory) This parameter indicates the mask of the operation and maintenance console for TGW. None None IP Address Type None 0.0.0.0~255.255.255.255 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The IP address of the TGW cannot use the configured IP address of another TGW. The IP address of TGW cannot be the same as the IP address configured in the BSC. Otherwise, operation and maintenance channel for TGW fails.
TGWPEERSN TGW TRANS Slot No. BSC6900 ADD TGWIP(Mandatory) Slot number of the BSC interface board interworking with TGW. None None Interval Type 0~5,8~27 0~5, 8~27 None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TGWPEERSRN TGW Trans Subrack No. BSC6900 ADD TGWIP(Mandatory) Subrack number of the BSC interface board interworking with TGW. None None Interval Type 0~11 0~11 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The IP address of the TGW cannot use the configured IP address of another TGW . The IP address of TGW cannot be the same as the IP address configured in the BSC. Otherwise, operation and maintenance channel for TGW fails.
TH Th BSC6900 SET BSSGPPARA(Optional) Timer Th. After receiving the MS flow control message, the SGSN uses the values of the updated Bmax and R based on the interval set by this timer. When this parameter is set to a smaller value, the SGSN can use the flow control parameter in a shorter time. In this way, the data can be transferred according to the most suitable flow control parameters, which can improve the transmission performance. When this parameter is set to a greater value, the SGSN uses the flow control parameter in a longer time. GBFD-114101GPRS Interval Type 5000~60000 5000~60000 ms None 5000 BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
THDOFF Volt Threshold for Off BSC6900 SET BTSAIRCON(Optional) Voltage threshold for switching off the air conditioner. If the power supply voltage is less than this threshold, the air conditioner needs to be switched off to decrease the impact on the BTS. GBFD-111202O&M of BTS Interval Type 220~280 220~280 V None 264 BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter is supported only by the BTS3012A and BTS3006A.
THDON Volt Threshold for On BSC6900 SET BTSAIRCON(Optional) Voltage threshold for switching on the air conditioner. This parameter assumes that the air conditioner is switched off. If the power supply voltage is greater than this threshold, the air conditioner needs to be switched on to ensure that the BTS runs properly. GBFD-111202O&M of BTS Interval Type 220~280 220~280 V None 264 BTS None Read & Write Y Not involved Not involved This parameter is supported only by the BTS3012A and BTS3006A.
THP1ARP1PRIWEIGHT THP1-ARP1 Priority Weight BSC6900 SET GCELLPSCHM(Optional) Combination of the THP1 and ARP1 priority in the Interactive service. THP1-ARP1 priority weight determines the number of the budget blocks and the block scheduling priority. GBFD-119902QoS ARP&THP Interval Type 1~10 1~10 None None 10 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
THP1ARP2PRIWEIGHT THP1-ARP2 Priority Weight BSC6900 SET GCELLPSCHM(Optional) Combination of the THP1 and ARP2 priority in the Interactive service. THP1-ARP2 priority weight determines the number of the budget blocks and the block scheduling priority. GBFD-119902QoS ARP&THP Interval Type 1~10 1~10 None None 6 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
THP1ARP3PRIWEIGHT THP1-ARP3 Priority Weight BSC6900 SET GCELLPSCHM(Optional) Combination of the THP1 and ARP3 priority in the Interactive service. THP1-ARP3 priority weight determines the number of the budget blocks and the block scheduling priority. GBFD-119902QoS ARP&THP Interval Type 1~10 1~10 None None 4 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
THP2ARP1PRIWEIGHT THP2-ARP1 Priority Weight BSC6900 SET GCELLPSCHM(Optional) Combination of the THP2 and ARP1 priority in the Interactive service. THP2-ARP1 priority weight determines the number of the budget blocks and the block scheduling priority. GBFD-119902QoS ARP&THP Interval Type 1~10 1~10 None None 8 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
THP2ARP2PRIWEIGHT THP2-ARP2 Priority Weight BSC6900 SET GCELLPSCHM(Optional) Combination of the THP2 and ARP2 priority in the Interactive service. THP2-ARP2 priority weight determines the number of the budget blocks and the block scheduling priority. GBFD-119902QoS ARP&THP Interval Type 1~10 1~10 None None 4 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
THP2ARP3PRIWEIGHT THP2-ARP3 Priority Weight BSC6900 SET GCELLPSCHM(Optional) Combination of the THP2 and ARP3 priority in the Interactive service. THP2-ARP3 priority weight determines the number of the budget blocks and the block scheduling priority. GBFD-119902QoS ARP&THP Interval Type 1~10 1~10 None None 3 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
THP3ARP1PRIWEIGHT THP3-ARP1 Priority Weight BSC6900 SET GCELLPSCHM(Optional) Combination of the THP3 and ARP1 priority in the Interactive service. THP3-ARP1 priority weight determines the number of the budget blocks and the block scheduling priority. GBFD-119902QoS ARP&THP Interval Type 1~10 1~10 None None 6 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
THP3ARP2PRIWEIGHT THP3-ARP2 Priority Weight BSC6900 SET GCELLPSCHM(Optional) Combination of the THP3 and ARP2 priority in the Interactive service. THP3-ARP2 priority weight determines the number of the budget blocks and the block scheduling priority. GBFD-119902QoS ARP&THP Interval Type 1~10 1~10 None None 3 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
THP3ARP3PRIWEIGHT THP3-ARP3 Priority Weight BSC6900 SET GCELLPSCHM(Optional) Combination of the THP3 and ARP3 priority in the Interactive service. THP3-ARP3 priority weight determines the number of the budget blocks and the block scheduling priority. GBFD-119902QoS ARP&THP Interval Type 1~10 1~10 None None 2 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
THTYPE Threshold type BSC6900 ADD TRMLOADTH(Mandatory) Load balance threshold type. It indicates the threshold calculation mode. None None Enumeration Type PERCENTAGE(Percentage), BANDWIDTH(Band Width) PERCENTAGE, BANDWIDTH None None None Transmission resource group None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
TI_WAIT_SGSN_PRIVATE_MESSAGE Receive SGSN Config. Msg. Timer BSC6900 SET BSCTMR(Optional) This parameter specifies the timer set to wait for a private message from the SGSN. GBFD-119701SGSN Pool Interval Type 1~15 1~15 min 5 5 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TIGHTBCCHASSMAINBCCHLEV Level Thresh. for Assgn BCCH Udr TBCCH BSC6900 SET GCELLCHMGAD(Optional) During channel assignment, the assignment of channels on the BCCH TRXs depends on the uplink receive level, quality, and non-BCCH load. The TCHs are preferentially assigned on the BCCH TRXs if the following conditions are met: 1. The uplink receive level after filtering is higher than "Level Thresh. for Assigning Main BCCH Carrier Channel Under TIGHT BCCH".2. The uplink receive quality level after filtering is lower than "Quality Thresh. for Assigning Main BCCH Carrier Channel Under TIGHT BCCH". 3. The non-BCCH load is higher than "Intracell Non Main BCCH Load Threshold of TIGHT BCCH". GBFD-118001BCCH Dense Frequency Multiplexing Interval Type 0~63 0~63 dB None 30 Cell This parameter is valid only when "TIGHTBCCHSWITCH" in "SET GCELLCHMGBASIC" is set to ON. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TIGHTBCCHASSMAINBCCHQUAL Quality Thresh. for Assgn BCCH Udr TBCCH BSC6900 SET GCELLCHMGAD(Optional) During channel assignment, the assignment of channels on the BCCH TRXs depends on the uplink receive level, quality, and non-BCCH load. The TCHs are preferentially assigned on the BCCH TRXs if the following conditions are met: 1. The uplink receive level after filtering is higher than "Level Thresh. for Assigning Main BCCH Carrier Channel Under TIGHT BCCH".2. The uplink receive quality level after filtering is lower than "Quality Thresh. for Assigning Main BCCH Carrier Channel Under TIGHT BCCH". 3. The non-BCCH load is higher than "Intracell Non Main BCCH Load Threshold of TIGHT BCCH". GBFD-118001BCCH Dense Frequency Multiplexing Interval Type 0~7 0~7 None None 1 Cell This parameter is valid only when "TIGHTBCCHSWITCH" in "SET GCELLCHMGBASIC" is set to ON. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TIGHTBCCHHOLASTTIME TIGHT BCCH HO Valid Time BSC6900 SET GCELLHOBASIC(Optional) The P/N criterion must be met for triggering a TIGHT BCCH handover. That is, the TIGHT BCCH handover can be triggered only if P seconds among N seconds meet the triggering conditions. This parameter corresponds to P in the P/N criterion. GBFD-118001BCCH Dense Frequency Multiplexing Interval Type 0~16 0~16 s None 2 Cell This parameter is valid only when "TIGHTBCCHSWITCH" in "SET GCELLCHMGBASIC" is set to ON. The following condition must be met: "TIGHTBCCHHOSTATTIME" >= "TIGHTBCCHHOLASTTIME". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TIGHTBCCHHOLOADTHRES Load Threshold for TIGHT BCCH HO BSC6900 SET GCELLHOAD(Optional) uring channel assignment, the assignment of channels on the BCCH TRXs depends on the uplink receive level, quality, and non-BCCH load. he TCHs are preferentially assigned on the BCCH TRXs if the following conditions are met: 1. The uplink receive level after filtering is higher than "Level Thresh. for Assigning Main BCCH Carrier Channel Under TIGHT BCCH". 2. The uplink receive quality level after filtering is lower than "Quality Thresh. for Assigning Main BCCH Carrier Channel Under TIGHT BCCH". 3. The non-BCCH load is higher than "Intracell Non Main BCCH Load Threshold of TIGHT BCCH". GBFD-118001BCCH Dense Frequency Multiplexing Interval Type 0~100 0~100 per cent None 80 Cell This parameter is valid only when "TIGHTBCCHSWITCH" in "SET GCELLCHMGBASIC" is set to ON. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TIGHTBCCHHOSTATTIME TIGHT BCCH HO Watch Time BSC6900 SET GCELLHOBASIC(Optional) The P/N criterion must be met for triggering a TIGHTBCCH handover. That is, the TIGHTBCCH handover can be triggered only if P seconds among N seconds meet the triggering conditions. This parameter corresponds to N in the P/N criterion. GBFD-118001BCCH Dense Frequency Multiplexing Interval Type 0~16 0~16 s None 3 Cell This parameter is valid only when "TIGHTBCCHSWITCH" in "SET GCELLCHMGBASIC" is set to ON. The following condition must be met: "TIGHTBCCHHOSTATTIME" >= "TIGHTBCCHHOLASTTIME". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TIGHTBCCHRXQUALTHRES RX_QUAL Threshold for TIGHT BCCH HO BSC6900 SET GCELLHOAD(Optional) When an intra-cell TIGHT BCCH handover needs to be performed (handover from the non-BCCH to BCCH), the downlink receive quality must be smaller than the value of this parameter. GBFD-118001BCCH Dense Frequency Multiplexing Interval Type 0~7 0~7 None None 3 Cell This parameter is valid only when "TIGHTBCCHSWITCH" in "SET GCELLCHMGBASIC" is set to ON. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TIGHTBCCHSWITCH TIGHT BCCH Switch BSC6900 SET GCELLCHMGBASIC(Optional) Whether to enable the BCCH aggressive frequency reuse algorithm. GBFD-118001BCCH Dense Frequency Multiplexing Enumeration Type OFF(Off), ON(On) OFF, ON None None OFF Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved Multi-band networks cannot use the TIGHT BCCH algorithm.
TIGHTSDCCHRXLEVTHRED IBCA Tight Trx SDCCH Rxlev Threshold BSC6900 SET GCELLCHMGAD(Optional) If the SDCCH load on the TRXs of the compatible BCCH in loose frequency reuse pattern is greater than the "IBCA Loose Trx SDCCH Load Threshold", and when the uplink receive level from the MS to the BTS is greater than the threshold, the SDCCHs on the TRXs of the compatible non-BCCH are preferentially assigned. Otherwise, the SDCCHs on the TRXs of the compatible BCCH are preferentially assigned. GBFD-117002IBCA (Interference Based Channel Allocation) Interval Type 0~63 0~63 dB None 40 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TIIMSIPAGING IMSI Paging Timer BSC6900 ADD GCNOPERATOR(Optional) IMSI paging timer. After enabling the MSC pool function, the BSC receives from the MSC the paging message attached with the IMSI. Then, the BSC records the relation between the IMSI and the MSC SP and starts the timer with predefined length.If the BSC receives a response message with the IMSI before the timer expires, the BSC locates the destination MSC based on the IMSI and MSC SP, and routes the current paging to the MSC.If the BSC does not receive a response when the timer expires, the BSC clears the relation information between the IMSI and MSC SP. GBFD-117401MSC Pool Interval Type 3~15 3~15 s 5 5 BSC6900This parameter is valid when "MSCPOOLALLOW" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TIME Time Limit BSC6900 ADD OP(Optional)Whether to limit the operation time of the operator GBFD-111203MRFD-210305 O&M of BSCSecurity Management Enumeration Type NOLIMIT(No Limit), LIMIT(Limit) NOLIMIT, LIMIT None NOLIMIT No Limit RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TIME Time Long BSC6900 SET FACFG(Mandatory) The time long of the parameter to be set. MRFD-210304Faulty Management Interval Type 1~15 1~15 min None None RNC None Read & Write Not involved Not involved Not involved None
TIME Time BSC6900 SET TIME(Optional) Time GBFD-111203O&M of BSC Compound Type HOUR, MIN, SEC 00:00:00~23:59:59 None None None RNC None Read & Write Not involved Not involved Not Involved None
TIME Duration BSC6900 SET GCELLFREQSCAN(Optional) Duration of frequency scanning GBFD-112401Cell Frequency Scan Interval Type 0,5~1440 0, 5~1440 min None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TIMEAMRFHPUNISH Penalty Time after AMR TCHF-H HO Fail BSC6900 SET GCELLHOFITPEN(Optional) Within the preset time, no AMR FR-to-HR handover is allowed if the previous FR-to-HR handover fails due to channel unavailability or channel mismatch. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 0~255 0~255 s None 10 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TIMEBQPUNISH Penalty Time after BQ HO BSC6900 SET GCELLHOFITPEN(Optional) After a handovr due to bad quality is successful, the penalty on the original serving cell is performed within the "Penalty Time after BQ HO": the receive level of the original serving cell is decreased by "Penalty Level after BQ HO", to prevent ping-pong handovers. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 0~255 0~255 s None 10 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TIMEOTOUFAILPUN Penalty Time after OtoU HO Fail BSC6900 SET GCELLHOIUO(Optional) After an OL subcell to UL subcell handover of an MS fails, the MS does not perform OL subell-UL subcell handovers within the value of the parameter. GBFD-113201Concentric Cell Interval Type 0~255 0~255 s None 10 Cell This parameter is valid only when "IUOTP" in "ADD GCELL" is set to Concentric_cell. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TIMEOUT Reply Time-Out[ms] BSC6900 PING IP(Optional) Indicates the timeout time of the PING packet None None Interval Type 200~10000 200~10000 ms 2000 2000 Ethernet port None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
TIMEOUT Reply Time-Out[ms] BSC6900 TRC IPADDR(Optional) Timeout time for waiting for the TRACERT packet response None None Interval Type 1~65535 1~65535 ms 3000 3000 None None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
Timeout Time Out BSC6900 PING MAC(Optional)PING BTSCFM(Optional) Timeout time None None Interval Type 1~3 1~3 s 2 2 Ethernet port None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
TIMEOUT Time Out BSC6900 TRC MAC(Optional)TRC BTSCFM(Optional) Indicates the timeout time of the CFM link tracing detection None None Interval Type 1~10 1~10 s 2 2 Ethernet port None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
TIMEOUT Time Out BSC6900 ADD BTSABISMUXFLOW(Optional) Longest waiting time for multiplexingWhen the multiplexed packet is no longer added with new data and the timer expires, the multiplexed packet is transmitted directly.This parameter is determined by the number of multiplexed packets. When the number of multiplexed packets increases, the value of this parameter increases. GBFD-118604Abis MUX Interval Type 5~200 5~200 (step: 0.1) ms 200 200 BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TIMEPUNISH Quick handover punish time BSC6900 ADD GEXT2GCELL(Optional)SET GCELLHOFAST(Optional) After the fast handover is successful, the penalty on the original serving cell is performed within the "Quick handover punish time": the receive level of the original serving cell is decreased by "Quick handover punish value", to prevent ping-pong handovers. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 0~255 0~255 s None 10 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TIMES Restore interface board times BSC6900 SET FACFG(Mandatory) Max times to restore interface board per day. MRFD-210304Faulty Management Interval Type 0~5 0~5 None None None RNC None Read & Write Not involved Not involved Not Involved None
TIMES Number of ping packets BSC6900 PING IP(Optional) Indicates the times of sending PING packets None None Interval Type 1~1024 1~1024 None 4 4 Ethernet port None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
TIMESLOTVOLADJALLOW Voltage Adjust Based Timeslots Allowed BSC6900 SET GCELLBASICPARA(Optional) This parameter determines whether the dynamic voltage adjustment function is enabled on the basis of the number of timeslots. GBFD-111606Power Optimization Based on Channel Type Enumeration Type NO(No), YES(Yes), NULL(Null) NO, YES, NULL None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TIMETAPUNISH Penalty Time after TA HO BSC6900 SET GCELLHOFITPEN(Optional) After the time advancing handover is successful, the penalty on the original serving cell is performed within the "Penalty Time after TA HO": the receive level of the original serving cell is decreased by "Penalty Level after TA HO", to prevent ping-pong handovers. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 0~255 0~255 s None 30 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TIMEUTOOFAILPUN Penalty Time after UtoO HO Fail BSC6900 SET GCELLHOIUO(Optional) After an UL subcell to OL subcell handover of an MS fails, the MS does not perform UL subcell to OL subcell handovers within the value of the parameter. GBFD-113201Concentric Cell Interval Type 10~255 10~255 s None 40 Cell This parameter is valid only when "IUOTP" in "ADD GCELL" is set to Concentric_cell. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TIQUEUINGTIMER T11 BSC6900 SET GCELLTMR(Optional) This parameter indicates the queue timer for assignment.When the BSC receives an assignment request and no channel is available for assignment, the BSC starts the queuing procedure and the timer. If the channel request is successful before the timer expires, the timer stops. If the timer expires, the channel assignment fails. GBFD-111005Enhanced Channel Assignment Algorithm Interval Type 1~30 1~30 s None 8 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TIWAITMSCMSG Receive MSC Configuration Message Timer BSC6900 ADD GCNOPERATOR(Optional) If the BSC receives the configuration data about all the connected MSCs before the timer expires, the BSC concludes that the configuration data is valid. GBFD-117401MSC Pool Interval Type 1~15 1~15 min 5 5 BSC6900This parameter is valid when "MSCPOOLALLOW" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TL Time Limit[Days] BSC6900 SET LOGLIMIT(Optional) When the operation time of the OMU exceeds the value specified by this parameter, some records are deleted from the operation log. GBFD-111203MRFD-210305 O&M of BSCSecurity Management Interval Type 7~365 7~365 None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TLLI TLLI BSC6900 SET MSTOCELL(Mandatory)TST SNDRSI(Mandatory)TST UPDMSRAC(Mandatory) Temporary logical ink ID, in the decimal format GBFD-114101GPRS Interval Type 0~4294967295 0~4294967295 None None None Subsystem This parameter is valid only when "IDXTYPE" is set to BYTLLI. Read & Write Not involved Not involved Not involved The parameter cannot be modified.
TLT Tout Limit BSC6900 SET BTSDHEUBP(Optional) Lowest expected value of the air outlet temperature.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. GBFD-111202O&M of BTS Interval Type -99~70 -99~70 degree Celsius None 45 BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TLTHD Temperature Alarm Lower Threshold BSC6900 SET BTSAPMUBP(Optional) Temperature alarm lower threshold. If the temperature of the battery is lower than the value of this parameter, an alarm indicating the abnormal temperature is reported.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. GBFD-111202O&M of BTS Interval Type -19~5 -19~5 degree Celsius None If "APMU Board Type" is "EPS4815", the recommended value is "0". For other types of APMU boards, the recommended value is "-10". BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TLTHD Temperature Alarm Lower Threshold BSC6900 SET BTSDHEUBP(Optional) When the internal temperature of the BTS reaches the Temperature Alarm Lower Threshold, it reports a low temperature alarm.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. GBFD-111202O&M of BTS Interval Type -99~99 -99~99 degree Celsius None -20 BTS The value of this parameter must be at least two degrees smaller than "Temperature Alarm Upper Threshold". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TM Execute Time BSC6900 ADD SUBTSK(Mandatory) When the time mode is set to "ONTIME", you should set this parameter. GBFD-111203O&M of BSC Compound Type hour, min 00:00~23:59 None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TM1 Execute Time 1 BSC6900 ADD SUBTSK(Mandatory) If the time mode is set to "DAILY_T", "WEEKLY_T", or "MONTHLY_T", you should set this parameter. This parameter specifies the first execution time in the day in which the scheduled task is executed. GBFD-111203O&M of BSC Compound Type hour, min 00:00~23:59 None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TM2 Execute Time 2 BSC6900 ADD SUBTSK(Optional) If the time mode is set to "DAILY_T", "WEEKLY_T", or "MONTHLY_T", you should set this parameter. This parameter specifies the second execution time in the day in which the scheduled task is executed. GBFD-111203O&M of BSC Compound Type hour, min 00:00~23:59 None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TM3 Execute Time 3 BSC6900 ADD SUBTSK(Optional) If the time mode is set to "DAILY_T", "WEEKLY_T", or "MONTHLY_T", you should set this parameter. This parameter specifies the third execution time in the day in which the scheduled task is executed. GBFD-111203O&M of BSC Compound Type hour, min 00:00~23:59 None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TM4 Execute Time 4 BSC6900 ADD SUBTSK(Optional) If the time mode is set to "DAILY_T", "WEEKLY_T", or "MONTHLY_T", you should set this parameter. This parameter specifies the fourth execution time in the day in which the scheduled task is executed. GBFD-111203O&M of BSC Compound Type hour, min 00:00~23:59 None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TM5 Execute Time 5 BSC6900 ADD SUBTSK(Optional) If the time mode is set to "DAILY_T", "WEEKLY_T", or "MONTHLY_T", you should set this parameter. This parameter specifies the fifth execution time in the day in which the scheduled task is executed. GBFD-111203O&M of BSC Compound Type hour, min 00:00~23:59 None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TMI TRMMAP ID BSC6900 ADD TRMMAP(Mandatory) TRMMAP indexNone None Interval Type 13~163 13~163 None None None BSC6900None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
TMIBRZ Bronze user TRMMAP index BSC6900 ADD ADJMAP(Mandatory) Bronze user TRMMAP index used by the current adjacent node None None Interval Type 0~163 0~163 None None None Adjacent node The TRMMAP index is configured by setting the value of "TMI" in "ADD TRMMAP". Read & Write N (No impact on the UE in idle mode) Not involved Not involved The TRMMAP must be configured.
TMIGLD Gold user TRMMAP index BSC6900 ADD ADJMAP(Mandatory) Gold user TRMMAP index used by the current adjacent node None None Interval Type 0~163 0~163 None None None Adjacent node The TRMMAP index is configured by setting the value of "TMI" in "ADD TRMMAP". Read & Write N (No impact on the UE in idle mode) Not involved Not involved The TRMMAP must be configured.
TMISLV Silver user TRMMAP index BSC6900 ADD ADJMAP(Mandatory) Silver user TRMMAP index used by the current adjacent node None None Interval Type 0~163 0~163 None None None Adjacent node The TRMMAP index is configured by setting the value of "TMI" in "ADD TRMMAP". Read & Write N (No impact on the UE in idle mode) Not involved Not involved The TRMMAP must be configured.
TMLEN Time Length BSC6900 STR FRPORTLOOP(Mandatory) Loopback time length. GBFD-510002Gb Over FR Interval Type 1~120 1~120 min None None BC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TMODE Test Mode BSC6900 STR BTSVSWRTST(Optional) Test mode GBFD-111207BTS Test Function Enumeration Type NON_FDR(NON_FDR), FDR(FDR) NON_FDR, FDR None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TMRBADQUALDISCSTAT Timer for Bad Quality DISC Statistic BSC6900 SET GCELLSOFT(Optional) Duration time for determining that a call is hung up because of poor quality GBFD-110501Call Control Interval Type 2~4 2~4 s None 3 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TMRISTHRD Upper time threshold of raised fault BSC6900 SET ALMBLKPARA(Optional) Maximum rate of the accumulated alarm blink duration to the alarm blink measurement period. Assume this threshold is not 0. When the rate of accumulated alarm blink duration exceeds the threshold, an alarm is reported. For querying the alarm blink measurement period, see "LST ALMBLKSW". For setting the alarm blink measurement period, see "SET ALMBLKSW". MRFD-210304Faulty Management Interval Type 0~100 0~100 per cent None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved 1. If you set "Upper time threshold of raised fault" and "Lower time threshold of raised fault" to "0", the accumulated alarm blink duration is counted but not reported.2. If "Upper time threshold of raised fault" is not "0", the value of "Lower time threshold of raised fault" cannot be "0" and you must ensure that "Upper time threshold of raised fault" is greater than "Lower time threshold of raised fault".3. When "Upper time threshold of raised fault" is not "0" and "Alarm switch of blinking filter" and "Switch of stat blinking alarm" are "ENABLE", you cannot set "Alarm blink threshold" to "0". Otherwise, blink statistics of the alarm is not performed.
TMSI TMSI BSC6900 CHK INNSPCH(Mandatory)STR CALLRESLOP(Mandatory) TMSI of the MSGBFD-111203O&M of BSC Interval Type 0~4294967295 0~4294967295 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TMSTLTHRD Lower time threshold of raised fault BSC6900 SET ALMBLKPARA(Optional) Minimum rate of the accumulated alarm blink duration to the alarm blink measurement period. Assume this threshold is not 0. When the rate of accumulated alarm blink duration is lower than the threshold, an alarm is reported. For querying the alarm blink measurement period, see "LST ALMBLKSW". For setting the alarm blink measurement period, see "SET ALMBLKSW". MRFD-210304Faulty Management Interval Type 0~100 0~100 per cent None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved 1. If you set "Upper time threshold of raised fault" and "Lower time threshold of raised fault" to "0", the accumulated alarm blink duration is counted but not reported.2. If "Upper time threshold of raised fault" is not "0", the value of "Lower time threshold of raised fault" cannot be "0" and you must ensure that "Lower time threshold of raised fault" is smaller than or equal to "Upper time threshold of raised fault".3. When "Lower time threshold of raised fault" is not "0" and "Alarm switch of blinking filter" and "Switch of stat blinking alarm" are "ENABLE", you cannot set "Alarm blink threshold" to "0". Otherwise, blink statistics of the alarm is not performed.
TMT1TMR Signalling link test ACK timer BSC6900 SET MTP3TMR(Optional) This timer is a protection timer waiting for a signalling link test acknowledgement message (SLTA) from the peer end after a signalling link test message (SLTM) is sent to the peer end. None None Interval Type 8000~12000 8000~12000 ms None None MTP3 linkNone Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TMT2TMR Signalling link repeat test timer BSC6900 SET MTP3TMR(Optional) This timer is used to send the signalling link test messages (SLTM) to the peer end regularly. None None Interval Type 30000~90000 30000~90000 ms None None MTP3 linkNone Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TNAME Data Table BSC6900 CMP TBLDATA(Mandatory) name of the data table distributed on the board. MRFD-210301Configuration Management Enumeration Type ABLMSGTYPEPARAS, ACALGOPARAS, ADMCTLPARAS, AICH, AMRCSQICOUNTPARAS, APN, BCH, CBSADDR, CBSCELLSAC, CELLACCESSCLASSBARREDLIST, CELLACCESSRESTRICT, CELLACCESSRESTRICTBARREDPARA, CELLACTTIMEOFFSET, CELLAMRCPARAS, CELLAMRCWBPARAS, CELLBASICINFO, CELLBCCHMODTIME, CELLBINDINFO, CELLCACLOADBALANCINGPARA, CELLCACPARA, CELLCBSDRXINFO, CELLCLOSEDLOOPTIMEADJUSTMODE, CELLCMBCH, CELLCMCFPARAS, CELLCTCHINFO, CELLDCCCPARAS, CELLDRDPARAS, CELLFRAMETIMING, CELLFRCPARAS, CELLHCSHOPARAS, CELLHCSPARAS, CELLHCSSYSINFOPARAS, CELLHOCOMMAPB, CELLHSDPAPARAS, CELLHSDPCCHPOPARAS, CELLHSUPAPARAS, CELLINTERFREQHOCOVAPB, CELLINTERFREQHONCOVAPB, CELLINTERFREQHOTAAPB, CELLINTERRATHOCOVAPB, CELLINTERRATHONCOVAPB, CELLINTRAFREQHOAPB, CELLLAC, CELLLACRAC, CELLLACSAC, CELLLDBPARAS, CELLLDMPARAS, CELLLDRPARAS, CELLMBMSCFGPARA, CELLMBMSFACH, CELLMBMSSA, CELLMBMSSCCPCH, CELLOLCPARAS, CELLOLPCPARAS, CELLPOSINFO, CELLPUCPARAS, CELLQOSHOAPB, CELLQUALITYMEASPARAS, CELLSELRESELINFO, CELLSELRESELMAXULTXPOWER, CELLSELRESELPCHFACH, CELLSELRESELQHYST2S, CE 0~276 None None None BSC6900None Read & Write Not involved Not involved Not involved None
TNMODE Transmission Mode BSC6900 ADD PBE1T1(Optional) E1 transmission type of the Pb interface. The terrestrial transmission or satellite transmission can be selected. In the areas such as desert and lake where the terrestrial transmission is difficult, the satellite transmission can be used. GBFD-111203O&M of BSC Enumeration Type TRRS(Terrestrial Transmission), SATEL(Satellite Transmission) TRRS, SATEL None None None PBE1T1 None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TNMODE Transmission Mode BSC6900 ADD ATERSL(Optional)ADD ATERCONSL(Optional) The Ater signaling link operates in the terrestrial transmission or satellite transmission mode. In the areas such as desert and lake where the terrestrial transmission is difficult, the satellite transmission can be used. GBFD-113903Satellite Transmission over Ater Interface Enumeration Type TRRS(Terrestrial Transmission), SATEL(Satellite Transmission) TRRS, SATEL None TRRS TRRS ATERCONSL None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TO AdjustMethod BSC6900 SET TZ(Mandatory) Offset to DST, namely, the adjustment to time. MRFD-210301Configuration Management Interval Type -120~-1,1~120 -120~-1, 1~120 min None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TO Cell reselect temporary offset BSC6900 SET GCELLIDLEAD(Optional) Cell Reselect Temporary Offset (TO) indicates the temporary correction of C2. This parameter is valid only within the value specified by "Cell reselect penalty time". For details, see GSM Rec. 05.08 and 04.08. This parameter applies to only GSM Phase II MSs. GBFD-110402Basic Cell Re-selection Interval Type 0~7 0~7 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TOPBOARDCN TOP Board Cabinet No. BSC6900 ADD BTSTOPCONFIG(Optional) Number of the cabinet where the board is located MRFD-211501IP-Based 2G/3G Co-Transmission on Base Station Side Interval Type 0~62 0~62 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TOPBOARDSLOTNO TOP Board Slot No BSC6900 ADD BTSTOPCONFIG(Mandatory) Number of the slot where the board is located MRFD-211501IP-Based 2G/3G Co-Transmission on Base Station Side Interval Type 0~23 0~23 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TOPBOARDSRN TOP Board Subrack No. BSC6900 ADD BTSTOPCONFIG(Optional) Number of the subrack where the board is located MRFD-211501IP-Based 2G/3G Co-Transmission on Base Station Side Interval Type 0~254 0~254 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TP Log Type BSC6900 COL FAMLOG(Mandatory) Type of the host log to be collected.If this parameter is set to NORMAL, the text log in the \common\fam\famlog directory of the OMU installation path is collected and saved in the \common\fam\famlog directory of the OMU installation path.If this parameter is set to FORMAT, the binary log in the \common\fam\famlogfmt directory of the OMU installation path is collected and saved in the \common\fam\famlogfmt directory of the OMU installation path. GBFD-111203O&M of BSC Enumeration Type NORMAL(TXT FORMAT), FORMAT(BIN FORMAT) NORMAL, FORMAT None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None.
TPN Tail Port No. BSC6900 ADD BTSRXUCHAIN(Mandatory)CBN BTSRXUCHAIN(Mandatory) The number of the optical port of the tail board in the RXU ring. GBFD-111202O&M of BTS Interval Type 0~5 0~5 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TQHO Into-BSC HO REQ Queue Timer BSC6900 SET GCELLTMR(Optional) Length of the timer that is started to wait for a channel requested by an incoming BSC handover request message.When the MSC allows the queuing of incoming BSC handover requests, the BSC starts the queuing procedure and the timer if no channel is available for assignment. If the channel request is successful before the timer expires, the timer stops. If the timer expires, the incoming BSC handover fails. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 1~30 1~30 s None 8 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TRACECTHD Debug tracking control threshold BSC6900 SET FCCPUTHD(Optional) CPU usage threshold for debugging tracing flow control. When the average CPU usage of sliding windows reaches or exceeds the threshold, debugging tracing flow control is triggered. WRFD-040100Flow Control Interval Type 30~100 30~100 per cent None 60 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TRACECTHD Debug tracking control threshold BSC6900 SET FCMSGQTHD(Optional) Packet queue usage threshold for debugging tracing flow control. When the average packet queue usage of sliding windows reaches or exceeds the threshold, debugging tracing flow control is triggered. WRFD-040100Flow Control Interval Type 30~100 30~100 per cent None 67 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TRACERTHD Debug tracking restore threshold BSC6900 SET FCCPUTHD(Optional) CPU usage threshold for recovery from debugging tracing flow control. When the average CPU usage of smooth windows is lower than the threshold, debugging tracing flow control is stopped. WRFD-040100Flow Control Interval Type 30~100 30~100 per cent None 50 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TRACERTHD Debug tracking restore threshold BSC6900 SET FCMSGQTHD(Optional) Packet queue usage threshold for recovery from debugging tracing flow control. When the average packet queue usage of smooth windows is lower than the threshold, debugging tracing flow control is stopped. WRFD-040100Flow Control Interval Type 30~100 30~100 per cent None 62 Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TRACESW Debug Flow control switch BSC6900 SET FCSW(Optional) Whether to control the debugging tracing flow WRFD-040100Flow Control Enumeration Type ON, OFF ON, OFF None None ON Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TrafficClassDlCoefficient DL Priority Decision Threshold BSC6900 SET BSCPSSOFTPARA(Optional) Threshold for determining whether the downlink service is perferred. Within the period specified by "Flow Count Period Ticks", if the length of the downlink LLC PDU received by the BSC from the SGSN higher than the threshold, the service type of the MS is downlink preferred. GBFD-119501Adaptive Adjustment of Uplink and Downlink Channels Interval Type 1~255 1~255 None None 5 BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TrafficClassUlCoefficient UL Priority Decision Threshold BSC6900 SET BSCPSSOFTPARA(Optional) Threshold for determining whether the uplink service is preferred. Within the period specified by "Flow Count Period Ticks", if the length of the uplink LLC PDU received by the BSC from the MS higher than the threshold, the service type of the MS is uplink preferred. GBFD-119501Adaptive Adjustment of Uplink and Downlink Channels Interval Type 1~255 1~255 None None 5 BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TRAMODE Traffic mode BSC6900 ADD M3LKS(Optional) Traffic mode of the M3UA link set. At present, only the active/standby and load sharing mode is available. For the description of the two modes, see the RFC4666. None None Enumeration Type M3UA_OVERRIDE_MOD(M3UA_OVERRIDE_MOD), M3UA_LOADSHARE_MOD(M3UA_LOADSHARE_MOD) M3UA_OVERRIDE_MOD, M3UA_LOADSHARE_MOD None M3UA_LOADSHARE_MOD M3UA_LOADSHARE_MOD BSC6900None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
TransMode Transmission Mode BSC6900 SET BTSTRANS(Mandatory) Mode of the transmission between the BTS and the BSC. The terrestrial transmission has a short delay while the satellite transmission has a long delay. GBFD-113901Satellite Transmission over Abis Interface Enumeration Type TER_TRANS(Terrestrial Transmission), SAT_TRANS(Satellite Transmission), TER_AND_SAT_TRANS(Terrestrial and Satellite) TER_TRANS, SAT_TRANS, TER_AND_SAT_TRANS None None None BTS None Read & Write Y BTS Less than 5 minutes None
TRANSSN Load Transmitting Slot No. BSC6900 ADD ABISLOADSHARE(Mandatory) Slot No. of the transparently transmitting interface board GBFD-111203O&M of BSC Interval Type 0~27 0~27 None None None None None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
TRANST Transport Type BSC6900 ADD ADJNODE(Mandatory) The transport type ATM_IP indicates that the adjacent node supports the dual stack of the ATM and IP. None None Enumeration Type ATM(ATM), IP(IP), ATM_IP(ATM and IP), HYBRID_IP(HYBRID IP) ATM, IP, ATM_IP, HYBRID_IP None None None Adjacent node When the value of "NODET" in "ADD ADJNODE" is set to IUB, IUR, IUCS, or IUPS, this parameter is valid. Read & Write Not involved Not involved Not involved The parameter cannot be modified.
TRANST Transport Type BSC6900 ADD IPPATH(Optional) Transport type of the adjacent node to which the path belongs. The parameter is valid only in the case of the transmission over the Iub interface. None None Enumeration Type IP(IP), HYBRID_IP(HYBRID IP) IP, HYBRID_IP None None None IP path None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
TRANST Transport Type of the adjacent node and interface type BSC6900 ADD ADJMAP(Mandatory) Transport type of the adjacent node and interface type GBFD-111601BTS Power Management Enumeration Type ATM(ATM), IP(IP), ATM_IP(ATM and IP), HYBRID_IP(HYBRID IP) ATM, IP, ATM_IP, HYBRID_IP None None None BSC6900When the value of "ITFT" in "ADD TRMMAP" is set to IUB_IUR_IUCS, this parameter is valid. Read & Write Not involved Not involved Not involved The parameter cannot be modified.
TRANST Transport Type BSC6900 ADD TRMMAP(Optional) Transport typeNone None Enumeration Type ATM, IP, ATM_IP, HYBRID_IP, HDLC ATM, IP, ATM_IP, HYBRID_IP, HDLC None None None BSC6900When the value of "ITFT" in "ADD TRMMAP" is set to IUB, IUR or IUCS, this parameter is valid. Read & Write Not involved Not involved Not involved The parameter cannot be modified.
TRANST Transport Type BSC6900 ADD TRMLOADTH(Mandatory) Transport typeNone None Enumeration Type ATM, IP, HDLC, TDM ATM, IP, HDLC, TDM None None None BSC6900When the value of "ITFT" in "ADD TRMMAP" is set to IUB, IUR or IUCS, this parameter is valid. Read & Write Not involved Not involved Not involved The parameter cannot be modified.
TRANSTYPE Carrier Type BSC6900 SET BTSABISPRIMAP(Mandatory) Transmission type of the BTS None None Enumeration Type IP, HDLC, TDM IP, HDLC, TDM None None None BSC6900None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
TRANSTYPE TRANSTYPE BSC6900 SET BTSBWPARA(Mandatory) Carrier Type GBFD-118601Abis over IP Enumeration Type HDLC, IP HDLC IP None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TRANSTYPE1 E1 Port 1 set optical transmission mode BSC6900 SET BTSDOMUBP(Optional) Whether to configure the optical transmission mode for E1 port 1 of the BTS3600C. If the optical transmission mode is configured, the BSC can connect to the BTS through optical fibers. GBFD-111202O&M of BTS Enumeration Type NO(NO), YES(YES) NO, YES None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TRANSTYPE2 E1 Port 2 set optical transmission mode BSC6900 SET BTSDOMUBP(Optional) Whether to configure the optical transmission mode for E1 port 2 of the BTS3600C. If the optical transmission mode is configured, the BSC can connect to the BTS through optical fibers. GBFD-111202O&M of BTS Enumeration Type NO(NO), YES(YES) NO, YES None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TRANSTYPE3 E1 Port 3 set optical transmission mode BSC6900 SET BTSDOMUBP(Optional) Whether to configure the optical transmission mode for E1 port 3 of the BTS3600C. If the optical transmission mode is configured, the BSC can connect to the BTS through optical fibers. GBFD-111202O&M of BTS Enumeration Type NO(NO), YES(YES) NO, YES None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TRCRNGLMT Trace Mode BSC6900 SET BTSCLKPARA(Mandatory) Whether to enable the limit of the tracing range GBFD-111202O&M of BTS Enumeration Type ENABLE(Enable Trace Range Limit), DISABLE(Disable Trace Range Limit) ENABLE, DISABLE h None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TRESEL Cell Reselection Forbidden Time BSC6900 SET GCELLRESELECTPARA(Optional) Forbidden time of cell reselection. GBFD-114101GPRS Enumeration Type 5sec(5sec), 10sec(10sec), 15sec(15sec), 20sec(20sec), 30sec(30sec), 60sec(60sec), 120sec(120sec), 300sec(300sec), nouse(no use) 5sec, 10sec, 15sec, 20sec, 30sec, 60sec, 120sec, 300sec, no use s None 10sec Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TRIGTHRES Load HO Threshold BSC6900 SET GCELLHOAD(Optional) The load handover is triggered when the traffic load in a cell is greater than the value of this parameter. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 0~100 0~100 None None 90 Cell This parameter is valid only when "LOADHOEN" in "SET GCELLHOBASIC" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TRKLNKPN Trunk Link No. BSC6900 ADD ETHTRKLNK(Mandatory) Port number of the aggregation member MRFD-210103Link aggregation Interval Type 0~11 0~7(FG2a), 0~1(GOUa), 0~11(FG2c), 0~3(GOUc) None None None Ethernet port None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
TRKLNKSN Trunk Link Slot No. BSC6900 ADD ETHTRKLNK(Mandatory) Slot number of the aggregation member MRFD-210103Link aggregation Interval Type 0~5,8~27 0~5, 8~27 None None None BSC6900None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
TRKN Trunk No. BSC6900 ADD ETHTRK(Mandatory)ADD ETHTRKLNK(Mandatory)ADD ETHTRKIP(Mandatory) aggregation group number MRFD-210103Link aggregation Interval Type 0~11 0~7(FG2a), 0~1(GOUa), 0~11(FG2c), 0~3(GOUc) None None None Ethernet port None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
TRMI User TRMMAP index BSC6900 SET BTSABISPRIMAP(Mandatory) Specified TRMMAP index of the user panel None None Interval Type 0~163 0~163 None None None BSC6900None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
TRMLOADTHINDEX TRM load threshold index BSC6900 ADD IPPATH(Optional) TRM load threshold index. The TRM load threshold must be configured. None None Interval Type 0~199 0~199 None 2 2 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The TRM load threshold must be configured already.
TRMLOADTHINDEX TRM load threshold index BSC6900 ADD RSCGRP(Optional) TRM load threshold index. The TRM load threshold must be configured. None None Interval Type 0~199 0~199 None 0 0 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The TRM load threshold must be configured already.
TRMLOADTHINDEX TRM load threshold index BSC6900 ADD TRMLOADTH(Mandatory) TRM load threshold index. It is the unique ID of the load threshold. None None Interval Type 10~199 10~199 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The TRM load threshold must be configured already.
TRMLOADTHINDEX TRM load threshold index BSC6900 ADD PPPLNK(Optional) TRM load threshold index GBFD-118611GBFD-118622 Abis IP over E1/T1A IP over E1/T1 Interval Type 0~199 0~199 None 2 2 PPP link None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
TRMLOADTHINDEX TRM load threshold index BSC6900 ADD MPGRP(Optional) TRM load threshold index GBFD-118611GBFD-118622 Abis IP over E1/T1A IP over E1/T1 Interval Type 0~199 0~199 None 2 2 None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TRMLOADTHINDEX TRM load threshold index BSC6900 ADD IPLOGICPORT(Optional) TRM load threshold index None None Interval Type 0~199 0~199 None 2 2 IP logical port None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
TRMLOADTHINDEX TRM load threshold index BSC6900 SET BTSABISPRIMAP(Mandatory) TRM load threshold index None None Interval Type 0~199 0~199 None None 0 None The TRM load threshold parameter must meet the following conditions: forward congestion recovery threshold < logical port bandwidth, backward congestion recovery threshold < logical port bandwidth. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TRMMAPSW Transport Resource Mapping switch BSC6900 SET BTSABISPRIMAP(Optional) Transmission resources mapping switch None None Enumeration Type OFF(OFF), ON(ON) OFF, ON None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TRUNKN The Trunk group No. BSC6900 ADD IPLOGICPORT(Optional) Trunk group number of the logical port None None Interval Type 0~11 0~11 None None None IP logical port None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
TRUNKN Trunk group No. BSC6900 STR IPCHK(Optional) TRUNK group number GBFD-118609IP Fault Detection Based on BFD Interval Type 0~11 0~11 None None None None None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
TRUNKN Trunk No. BSC6900 ADD ETHMEP(Mandatory) TRUNK group number GBFD-118630Ethernet OAM Interval Type 0~11 0~11 None None None Ethernet port None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
TRXAIDSWITCH TRX Aiding Function Control BSC6900 SET GCELLCCACCESS(Optional) Whether to enable the TRX aiding function. Four aiding modes are available. BCCH aiding: The main BCCH is aided to another normal TRX in this cell. BCCH aiding switchback: BCCH aiding switchback functions after the originally configured BCCH TRX is recovered. Baseband FH aiding: When the TRX involved in baseband FH in the cell is faulty or BCCH aiding is performed in the cell, baseband FH aiding occurs and the cell is initialized as a non-hopping cell. Baseband FH aiding switchback: When all the TRXs involved in baseband hopping in the cell are recovered and the originally configured BCCH TRX is normal, baseband FH aiding switchback can be performed and the cell is restored to the baseband FH mode. GBFD-113801TRX Cooperation Enumeration Type TRXAid_NotAllow(TRX Aiding Not Allowed), AllowReForbid(Allowed & Recover Forbidden), AllowReImmed(Allowed & Recover Immediately), AllowReCheckRes(Allowed & Recover When Chk Res) TRXAid_NotAllow, AllowReForbid, AllowReImmed, AllowReCheckRes None None AllowReCheckRes Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter specifies whether to enable the TRX aiding function.BCCH aiding: The main BCCH is aided to another normal TRX in this cell.BCCH aiding switchback: BCCH aiding switchback functions after the originally configured BCCH TRX is recovered.Baseband FH aiding: When the TRX involved in baseband FH in the cell is faulty or BCCH aiding is performed in the cell, baseband FH aiding occurs and the cell is initialized as a non-hopping cell.Baseband FH aiding switchback: When all the TRXs involved in baseband hopping in the cell are recovered and the originally configured BCCH TRX is normal, baseband FH aiding switchback can be performed and the cell is restored to the baseband FH mode.After TRX aiding (BCCH aiding or baseband FH aiding) or switchback occurs, the cell is re-initialized.For any types of BTS, no aiding is performed within 15 minutes after the cell is initialized.
TRXDURATS Duration Second BSC6900 STR BTSTST(Mandatory) Duration GBFD-111207BTS Test Function Interval Type 5~10 5~10 h None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TRXHOPINDEX Channel Hop Index BSC6900 SET GTRXCHANHOP(Optional) Frequency hopping index of the channel in the TRX GBFD-113701Frequency Hopping (RF hopping, baseband hopping) Interval Type 0~63,255 0~63, 255 None None None Physical channel None Read & Write Services will be disrupted if the handover fails after the parameter modification. Cell Less than 1 minute After this parameter is modified, the services in the cell are handed over forcedly. The cell is reset (after ten seconds) after the handover succeeds. This protects the services from being interrupted.
TRXID TRX ID BSC6900 SET FHO(Mandatory)SET GTRXCHANHOP(Mandatory)SET GTRXHOP(Mandatory)SET GTRXBASE(Mandatory)SET GTRXCHAN(Mandatory)SET GTRXFC(Mandatory)SET GTRXIUO(Mandatory)SET GTRXADMSTAT(Mandatory)SET GTRXCHANADMSTAT(Mandatory)ADD GTRX(Mandatory)ADD TRXBIND2PHYBRD(Mandatory)SET GTRXRLALM(Mandatory)SET GTRXDEV(Mandatory)STR BTSTST(Mandatory)STR TRXBURSTTST(Mandatory) ID of the TRX. The TRX ID must be globally unique. MRFD-210301Configuration Management Interval Type 0~3071 0~3071 None None None TRX None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
TRXID TRX ID BSC6900 ADD BTSBINDLOCGRP(Mandatory) The ID of TRX added in the main location group. The same TRX cannot be bound by the TRX boards in a same location group for multiple times. GBFD-510104Multi-site Cell Interval Type 0~3071 0~3071 None None None BTS None Read & Write Y BTS Less than 5 minutes None
TRXID TRX Index BSC6900 ADD GTRXBIND2HDLCPATH(Mandatory) TRXID bind to the HDLC path. GBFD-118601Abis over IP Interval Type 0~3071 0~3071 None None None BTS None Read & Write Y BTS Less than 5 minutes The parameter cannot be modified.
TRXID1 No.1 TRX ID BSC6900 ADD GCELLHOPANTGRP(Optional) Index of TRX 1GBFD-113703Antenna Frequency Hopping Interval Type 0~3071 0~3071 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TRXID10 No.10 TRX ID BSC6900 ADD GCELLHOPANTGRP(Optional) Index of TRX 10 GBFD-113703Antenna Frequency Hopping Interval Type 0~3071 0~3071 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TRXID11 No.11 TRX ID BSC6900 ADD GCELLHOPANTGRP(Optional) Index of TRX 11 GBFD-113703Antenna Frequency Hopping Interval Type 0~3071 0~3071 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TRXID12 No.12 TRX ID BSC6900 ADD GCELLHOPANTGRP(Optional) Index of TRX 12 GBFD-113703Antenna Frequency Hopping Interval Type 0~3071 0~3071 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TRXID13 No.13 TRX ID BSC6900 ADD GCELLHOPANTGRP(Optional) Index of TRX 13 GBFD-113703Antenna Frequency Hopping Interval Type 0~3071 0~3071 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TRXID14 No.14 TRX ID BSC6900 ADD GCELLHOPANTGRP(Optional) Index of TRX 14 GBFD-113703Antenna Frequency Hopping Interval Type 0~3071 0~3071 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TRXID15 No.15 TRX ID BSC6900 ADD GCELLHOPANTGRP(Optional) Index of TRX 15 GBFD-113703Antenna Frequency Hopping Interval Type 0~3071 0~3071 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TRXID16 No.16 TRX ID BSC6900 ADD GCELLHOPANTGRP(Optional) Index of TRX 16 GBFD-113703Antenna Frequency Hopping Interval Type 0~3071 0~3071 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TRXID17 No.17 TRX ID BSC6900 ADD GCELLHOPANTGRP(Optional) Index of TRX 17 GBFD-113703Antenna Frequency Hopping Interval Type 0~3071 0~3071 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TRXID18 No.18 TRX ID BSC6900 ADD GCELLHOPANTGRP(Optional) Index of TRX 18 GBFD-113703Antenna Frequency Hopping Interval Type 0~3071 0~3071 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TRXID19 No.19 TRX ID BSC6900 ADD GCELLHOPANTGRP(Optional) Index of TRX 19 GBFD-113703Antenna Frequency Hopping Interval Type 0~3071 0~3071 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TRXID2 No.2 TRX ID BSC6900 ADD GCELLHOPANTGRP(Optional) Index of TRX 2GBFD-113703Antenna Frequency Hopping Interval Type 0~3071 0~3071 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TRXID20 No.20 TRX ID BSC6900 ADD GCELLHOPANTGRP(Optional) Index of TRX 20 GBFD-113703Antenna Frequency Hopping Interval Type 0~3071 0~3071 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TRXID21 No.21 TRX ID BSC6900 ADD GCELLHOPANTGRP(Optional) Index of TRX 21 GBFD-113703Antenna Frequency Hopping Interval Type 0~3071 0~3071 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TRXID22 No.22 TRX ID BSC6900 ADD GCELLHOPANTGRP(Optional) Index of TRX 22 GBFD-113703Antenna Frequency Hopping Interval Type 0~3071 0~3071 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TRXID23 No.23 TRX ID BSC6900 ADD GCELLHOPANTGRP(Optional) Index of TRX 23 GBFD-113703Antenna Frequency Hopping Interval Type 0~3071 0~3071 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TRXID24 No.24 TRX ID BSC6900 ADD GCELLHOPANTGRP(Optional) Index of TRX 24 GBFD-113703Antenna Frequency Hopping Interval Type 0~3071 0~3071 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TRXID3 No.3 TRX ID BSC6900 ADD GCELLHOPANTGRP(Optional) Index of TRX 3GBFD-113703Antenna Frequency Hopping Interval Type 0~3071 0~3071 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TRXID4 No.4 TRX ID BSC6900 ADD GCELLHOPANTGRP(Optional) Index of TRX 4GBFD-113703Antenna Frequency Hopping Interval Type 0~3071 0~3071 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TRXID5 No.5 TRX ID BSC6900 ADD GCELLHOPANTGRP(Optional) Index of TRX 5GBFD-113703Antenna Frequency Hopping Interval Type 0~3071 0~3071 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TRXID6 No.6 TRX ID BSC6900 ADD GCELLHOPANTGRP(Optional) Index of TRX 6GBFD-113703Antenna Frequency Hopping Interval Type 0~3071 0~3071 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TRXID7 No.7 TRX ID BSC6900 ADD GCELLHOPANTGRP(Optional) Index of TRX 7GBFD-113703Antenna Frequency Hopping Interval Type 0~3071 0~3071 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TRXID8 No.8 TRX ID BSC6900 ADD GCELLHOPANTGRP(Optional) Index of TRX 8GBFD-113703Antenna Frequency Hopping Interval Type 0~3071 0~3071 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TRXID9 No.9 TRX ID BSC6900 ADD GCELLHOPANTGRP(Optional) Index of TRX 9GBFD-113703Antenna Frequency Hopping Interval Type 0~3071 0~3071 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TRXIDLST TRXID LST BSC6900 SET GCELLHOPQUICKSETUP(Optional)SET GCELLHOPANTQUICKSETUP(Optional) List of IDs of carriers for frequency hopping. GBFD-113701Frequency Hopping (RF hopping, baseband hopping) String Type None 1~120 characters None None None BSC6900None Read & Write Y Cell Less than 5 minutes None
TRXIDLST TRX Index List BSC6900 STR TRXPERFTST(Mandatory) List of TRX indexes. You can specify one TRX index (for example, 1) or more TRX indexes (for example, 0&1&2) in the same BTS. GBFD-111207BTS Test Function Interval Type 0~3071 0~3071 None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TRXMAIO Channel MAIO BSC6900 SET GTRXCHANHOP(Optional) Mobile allocation index offset (MAIO) of the channel in the TRX GBFD-113701Frequency Hopping (RF hopping, baseband hopping) Interval Type 0~63 0~63 None None None Physical channel None Read & Write N (No impact on the UE in idle mode) Cell Less than 1 minute After this parameter is modified, the services in the cell are handed over forcedly. The cell is reset (after ten seconds) after the handover succeeds. This protects the services from being interrupted.
TrxNum TRX Number BSC6900 ADD BTSBRDCAP(Mandatory)ADD BTSRXUBRD(Optional) Allowed number of carriers bound to a board. GBFD-111202O&M of BTS Interval Type 0~8 0~8 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TRXPN TRX Board Pass No. BSC6900 ADD TRXBIND2PHYBRD(Mandatory) Number of the channel bound to the TRX on the TRX board GBFD-111202O&M of BTS Interval Type 0~7 0~7 None None None TRX None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
TRXPN Sub-Location Group TRX Board Pass No. BSC6900 ADD BTSBINDLOCGRP(Mandatory) TRX board pass number in the sub-location group to which the TRX of the main location group is bound GBFD-510104Multi-site Cell Interval Type 0~7 0~7 None None None TRX None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
TRXPRIALLOW Allocation TRX Priority Allowed BSC6900 SET GCELLCHMGAD(Optional) Whether the TRX priority is considered during channel assignment. GBFD-111005Enhanced Channel Assignment Algorithm Enumeration Type NO(No), YES(Yes)NO, YES None None YES Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TRXTP TRX Board Type BSC6900 ADD TRXBIND2PHYBRD(Mandatory) Type of the TRX board bound to the TRX GBFD-111202O&M of BTS Enumeration Type TRX(TRX), TRU(TRU/DTRU), QTRU(QTRU), DRRU(DRRU), DRFU(DRFU), MRRU(MRRU), MRFU(MRFU), GRFU(GRFU), GRRU(GRRU), BTS3900B(BTS3900B), BTS3900E(BTS3900E) TRX, TRU, QTRU, DRRU, DRFU, MRRU, MRFU, GRFU, GRRU, BTS3900B, BTS3900E None None None TRX None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
TS Time Slot BSC6900 BLK ATERE1T1(Mandatory) It indicates the Ater interface timeslot No. GBFD-111801Ater Interface 4:1 Multiplexing Interval Type 8~255 8~255 None None None E1/T1 linkWhen the value of "OPMODE" of "BLK ATERE1T1" is BYCICVALUE, the value of TS needs to be set. Read & Write N (No impact on the UE in idle mode) Not involved Not involved 1. The block of Ater interface must be configured. 2. If the BSC is configured to the integrated BMTC or A over IP is configured, the configuration does not support the operation. 3. If the block operation is applicable to only the ATERTS of the BM subrack. You are not allowed to perform the block operation from the primary BM subrack to the secondary BM subrack.
TS Time Slot BSC6900 BLK AE1T1(Mandatory) It indicates the A interface timeslot No. The parameter supports multiple values. GBFD-111803A Interface Circuit Management Interval Type 1~31 1~31, step:8 None None None E1/T1 linkWhen the value of "OPMODE" of "BLK AE1T1" is BYCICVALUE, the value of TS needs to be set. Read & Write N (No impact on the UE in idle mode) Not involved Not involved 1. The block of A interface must be configured. 2. If the BSC is configured to the integrated BMTC or A over IP is configured, the configuration does not support the operation. 3. If the block operation is applicable to only the AE1T1 of the BM subrack. You are not allowed to perform the block operation from the primary BM subrack to the secondary BM subrack.
TS time slot No. BSC6900 LOP E1T1(Mandatory)STR E1T1TST(Optional) Timeslot number None None Enumeration Type TS1(Time_slot_1), TS2(Time_slot_2), TS3(Time_slot_3), TS4(Time_slot_4), TS5(Time_slot_5), TS6(Time_slot_6), TS7(Time_slot_7), TS8(Time_slot_8), TS9(Time_slot_9), TS10(Time_slot_10), TS11(Time_slot_11), TS12(Time_slot_12), TS13(Time_slot_13), TS14(Time_slot_14), TS15(Time_slot_15), TS16(Time_slot_16), TS17(Time_slot_17), TS18(Time_slot_18), TS19(Time_slot_19), TS20(Time_slot_20), TS21(Time_slot_21), TS22(Time_slot_22), TS23(Time_slot_23), TS24(Time_slot_24), TS25(Time_slot_25), TS26(Time_slot_26), TS27(Time_slot_27), TS28(Time_slot_28), TS29(Time_slot_29), TS30(Time_slot_30), TS31(Time_slot_31) TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10, TS11, TS12, TS13, TS14, TS15, TS16, TS17, TS18, TS19, TS20, TS21, TS22, TS23, TS24, TS25, TS26, TS27, TS28, TS29, TS30, TS31 None None None Cell None Read & Write Y Cell Less than 5 minutes Loopback test, which cause the service interruption on this link
TS Bearing Timeslot BSC6900 ADD BC(Mandatory) Timesolt of bearing channels. GBFD-510002Gb Over FR Bit Field Type TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10, TS11, TS12, TS13, TS14, TS15, TS16, TS17, TS18, TS19, TS20, TS21, TS22, TS23, TS24, TS25, TS26, TS27, TS28, TS29, TS30, TS31 2~4294967294 None None None BC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TS Timeslot NO. BSC6900 SET BTSOMLTS(Mandatory) Number of the timeslot on the port GBFD-111203O&M of BSC Interval Type 1~31 1~31 None None None BTS None Read & Write Y BTS Less than 5 minutes None
TS16ENABLE 16TimeSlot switch BSC6900 SET E1T1(Optional) Whether to use timeslot 16 None None Enumeration Type OFF(OFF), ON(ON) OFF, ON None None None E1/T1 port None Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter is valid only in the E1 mode of the AEUa.
TSBITMAP Bearing time slot BSC6900 ADD PPPLNK(Mandatory) Bearer E1T1 port timeslot GBFD-118611GBFD-118622 Abis IP over E1/T1A IP over E1/T1 Bit Field Type TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10, TS11, TS12, TS13, TS14, TS15, TS16, TS17, TS18, TS19, TS20, TS21, TS22, TS23, TS24, TS25, TS26, TS27, TS28, TS29, TS30, TS31 TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10, TS11, TS12, TS13, TS14, TS15, TS16, TS17, TS18, TS19, TS20, TS21, TS22, TS23, TS24, TS25, TS26, TS27, TS28, TS29, TS30, TS31 None None None PPP link None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
TSBITMAP Bearing time slot BSC6900 ADD MPLNK(Mandatory) Bearer E1T1 port timeslot GBFD-118611GBFD-118622 Abis IP over E1/T1A IP over E1/T1 Bit Field Type TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10, TS11, TS12, TS13, TS14, TS15, TS16, TS17, TS18, TS19, TS20, TS21, TS22, TS23, TS24, TS25, TS26, TS27, TS28, TS29, TS30, TS31 TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10, TS11, TS12, TS13, TS14, TS15, TS16, TS17, TS18, TS19, TS20, TS21, TS22, TS23, TS24, TS25, TS26, TS27, TS28, TS29, TS30, TS31 None None None MP link None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TSBITMAP Bearing time slot BSC6900 ADD BTSPPPLNK(Mandatory)ADD BTSMPLNK(Mandatory) Timeslot of the E1/T1 link carrying the PPP link. The timeslot of an E1 port cannot be used by different PPP links. GBFD-118611Abis IP over E1/T1 Bit Field Type TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10, TS11, TS12, TS13, TS14, TS15, TS16, TS17, TS18, TS19, TS20, TS21, TS22, TS23, TS24, TS25, TS26, TS27, TS28, TS29, TS30, TS31 TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10, TS11, TS12, TS13, TS14, TS15, TS16, TS17, TS18, TS19, TS20, TS21, TS22, TS23, TS24, TS25, TS26, TS27, TS28, TS29, TS30, TS31 None None Timeslot 1 should be one of the bearing timeslots in the link. BTS None Read & Write Y PPP link Less than 5 minutes The modification of the PPP link that is between the BTS and the BSC will affect the services.The modification of the PPP link that is between the BTS and the lower-level BTSs will lead to intermittent services carried by the lower-level BTSs.
TSC TSC BSC6900 ADD GCELLMAGRP(Optional) The TSC is short for the Training Sequence Code.The TSC must be the same as the BCC. The delay equalization is performed by using the specified TSC when the MS or BTS receives the signal. The demodulation cannot be received because the delay equalization cannot be performed for the signals with same frequency using different TSCs. This can effectively prevent incorrectly invalid reception, and prevent the co-channel interference. GBFD-113701Frequency Hopping (RF hopping, baseband hopping) Interval Type 0~7 0~7 None None None Cell None Read & Write Y Cell Less than 1 minute None
TSCOUNT Idle Ts Count BSC6900 SET BTSIDLETS(Mandatory) Number of idle timeslots. You can configure up to 128 idle timeslots for the BTS at a time. A BTS can be configured with up to 512 idle timeslots. GBFD-114101GPRS Interval Type 0~512 0~512 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TSCPLANEN TSC Plan Enable BSC6900 SET GCELLSOFT(Optional) Whether to allow TSC planning. If this parameter is set to No, the TSC values in all MA groups of the cell cannot be modified. In this case, the TSC values are automatically refreshed to the BCC values of the cell. GBFD-118201Soft-Synchronized Network Enumeration Type NO(No), YES(Yes)NO, YES None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TSCROSSX Time slot cross index BSC6900 ADD TSCROSS(Optional) Timeslot cross index None None Interval Type 0~65535 0~65535 None None None E1/T1 port None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TSDURAT Duration * 10 minutes BSC6900 STR TRANSPERFTST(Mandatory) Duration in timeslot mode GBFD-111207BTS Test Function Interval Type 1~144 10~1440 (step: 10) min None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TSIDX Timeslot Index BSC6900 ADD BTSMONITORTS(Optional) Index of the monitoring timeslot. The index is unique in a BTS. GBFD-114701Semi-Permanent Connection Interval Type 0~127 0~127 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TSKN Task Name BSC6900 ADD SCHTSK(Mandatory)SET SCHTSKSW(Optional)ADD SUBTSK(Optional)ADD SUBCMD(Optional)STR SCHTSK(Optional) Name of the scheduled task. GBFD-111203O&M of BSC String Type None 1~50 characters None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TSMASK Timeslot Mask BSC6900 ADD ATEROML(Mandatory) Time slots for Ater operation and maintenance. These time slots are provided by the ports connected to the Ater connection path. MRFD-210301Configuration Management Bit Field Type TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10, TS11, TS12, TS13, TS14, TS15, TS16, TS17, TS18, TS19, TS20, TS21, TS22, TS23, TS24, TS25, TS26, TS27, TS28, TS29, TS30, TS31 TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10, TS11, TS12, TS13, TS14, TS15, TS16, TS17, TS18, TS19, TS20, TS21, TS22, TS23, TS24, TS25, TS26, TS27, TS28, TS29, TS30, TS31 None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TSMASK TS Mask BSC6900 ADD BTSTOPCONFIG(Mandatory)ADD BTSABISHDLCPATH(Mandatory) The 64 kbit/s timeslots on the port are numbered from 1 to 31. MRFD-211501IP-Based 2G/3G Co-Transmission on Base Station Side Bit Field Type TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10, TS11, TS12, TS13, TS14, TS15, TS16, TS17, TS18, TS19, TS20, TS21, TS22, TS23, TS24, TS25, TS26, TS27, TS28, TS29, TS30, TS31 TS1, TS2, TS3, TS4, TS5, TS6, TS7, TS8, TS9, TS10, TS11, TS12, TS13, TS14, TS15, TS16, TS17, TS18, TS19, TS20, TS21, TS22, TS23, TS24, TS25, TS26, TS27, TS28, TS29, TS30, TS31 None None None BTS None Read & Write Y BTS Less than 5 minutes None
TSN TAIL Slot No. BSC6900 ADD BTSRXUCHAIN(Mandatory)CBN BTSRXUCHAIN(Mandatory) Number of the slot where the tail board of the RXU ring is located. The slot No. is unique in the same BTS. GBFD-111202O&M of BTS Interval Type 0~23 0~23 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TSNO Timeslot No. BSC6900 ADD PBSL(Mandatory) Timeslot No. of Pb signaling link. GBFD-111203O&M of BSC Interval Type 1~31 1~31 None None None PBSL None Read & Write Y BSC6900 The services are interrupted until the PBSL is working normally. None
TSPRIORITY Timeslot Priority BSC6900 SET GTRXCHAN(Optional) Assignment priority level of the channel. If this parameter is less, the assignment priority level of the channel is higher. GBFD-111005Enhanced Channel Assignment Algorithm Interval Type 0~7 0~7 None None None Physical channel None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TSPWRRESERVE Timeslot Power Reserve BSC6900 SET GTRXDEV(Optional) Maximum degree by which the output power of the multi-density TRX board can exceed the maximum output power within a short time GBFD-111005Enhanced Channel Assignment Algorithm Interval Type 0~50 0~50 W None If the board is configured with two to four TRXs, the recommended value of this parameter is 20. If the board is configured with five TRXs, the recommended value of this parameter is 50. If the board is configured with six TRXs, the recommended value of this parameter is 48. TRX None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TSRAPIDADJPERIOD Fast Flux Measurement TBF Timer BSC6900 SET BSCPSSOFTPARA(Optional) Fast flux measurement duration. Normal flux measurement is performed after the fast flux measurement lasts over the period specified by this parameter. GBFD-119501Adaptive Adjustment of Uplink and Downlink Channels Interval Type 0~65535 0~65535 ms None 5000 BSC The value of "Fast Flux Measurement Period" cannot be greater than that of "Fast Flux Measurement TBF Time". Read & Write N (No impact on the UE in idle mode) Not involved Not involved If this parameter is set to a great value, the PS DSP load will be heavy.
TSRAPIDADJSWITCH Fast Flux Detection Switch BSC6900 SET BSCPSSOFTPARA(Optional) Whether to enable fast flux detection. When this parameter is set to Open, fast timeslot adjustment is possible after the TBF is set up. GBFD-119501Adaptive Adjustment of Uplink and Downlink Channels Enumeration Type Close(Close), Open(Open) Close, Open None None Open BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TSRATE Time Slot Rate BSC6900 ADD BTSMONITORTS(Mandatory) Rate of the monitoring timeslot GBFD-114701Semi-Permanent Connection Enumeration Type 8K(8K), 16K(16K), 32K(32K), 64K(64K) 8K, 16K, 32K, 64K kbit/s None None BTS If this parameter is set to "16K", "In-BSC Sub Timeslot No." and "Out-BTS Sub Timeslot No." must be 0, 2, 4, or 6. If this parameter is set to "32K", "In-BSC Sub Timeslot No." and "Out-BTS Sub Timeslot No." must be 0 or 4. If this parameter is set to "64K", "In-BSC Sub Timeslot No." and "Out-BTS Sub Timeslot No." must be 0. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TSRN TAIL Subrack No. BSC6900 ADD BTSRXUCHAIN(Mandatory)CBN BTSRXUCHAIN(Mandatory) Number of the subrack where the tail board of the RXU ring is located. The subrack No. is unique in the same BTS. GBFD-111202O&M of BTS Interval Type 0~254 0~254 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TSTMODE Test Mode BSC6900 STR BTSTST(Mandatory) Test mode GBFD-111207BTS Test Function Enumeration Type TRXLOOPBACK(TRX Loopback Test), CHLLOOPBACK(Channel Loopback Test), CHLCODEC(Speech codec Test) TRXLOOPBACK, CHLLOOPBACK, CHLCODEC None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TSTTIMESLOT Test Timeslot BSC6900 STR TRANSPERFTST(Mandatory) Test timeslot GBFD-111202O&M of BTS Interval Type 0~31 0~31 None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TSTTYPE Test Type BSC6900 STR BTSBATTTST(Mandatory) Type of battery test GBFD-111207BTS Test Function Enumeration Type SIMPLETEST(Simple Test), MANUALTEST(Manual Test) SIMPLETEST, MANUALTEST None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TsTurningOffEnable Allow Turning Off Time Slot BSC6900 SET BSCDSTPA(Optional) Whether to allow the BTS to enable the timeslot shutdown PA function. If the BTS enables and supports this function, the BTS will periodically report the number of times for timeslot shutdown. GBFD-111603TRX Power Amplifier Intelligent Shutdown on Timeslot Level Enumeration Type NO(No), YES(Yes)NO, YES None None NO BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TT Topo Type BSC6900 ADD BTSRXUCHAIN(Mandatory) RXU topology type, that is, RXU ring topology or RXU chain topology. In the case of the ring topology, the optical ports of the head and tail boards must be specified. In the case of the chain topology, only the optical port of the head board must be specified. GBFD-111202O&M of BTS Enumeration Type CHAIN(Chain), RING(Ring) CHAIN, RING None None None BTS None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
5/5/2014
Confidential Information of Huawei.
No Spreading without Permission
Page20of42
226347869.xls.ms_office Security Level:
TTIME Duration time BSC6900 STR CPUUSAGETST(Mandatory) Duration of the CPU usage test MRFD-210301Configuration Management Interval Type 1~4294967295 1~4294967295 ms None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TTL Time to Live BSC6900 PING IP(Optional) TTL(Time to Live) of the PING packet None None Interval Type 1~255 1~255 None 64 64 Ethernet port None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
TTL PKT TTL BSC6900 TRC MAC(Optional)TRC BTSCFM(Optional) Indicates the live time of the packet for CFM link tracing detection None None Interval Type 1~128 1~128 s 64 64 Ethernet port None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
TURNOFFCELLCHANNUM Dyn. Turning Off Cell Busy Channel Num. BSC6900 SET GCELLDYNTURNOFF(Optional) Within the period when cell disabling is allowed, if the number of occupied channels, including the PDCH and TCH, in the cell to be disabled is below the threshold, the procedure for disabling the cell is triggered. GBFD-111610Dynamic Cell Power Off Interval Type 0~8 0~8 None None 6 Cell This parameter is valid only when "TURNOFFENABLE" is set to ENABLE. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TURNOFFCELLSTPTIME Dyn. Turning Off Cell Stop Time BSC6900 SET GCELLDYNTURNOFF(Optional) End time of dynmatically disabling cells, that is, after the time, cells are not allowed to be disabled. GBFD-111610Dynamic Cell Power Off Compound Type HOUR, MINUTE 00:00~23:59 None None None Cell This parameter is valid only when "TURNOFFENABLE" is set to ENABLE. The following condition must be met: "TURNOFFCELLSTPTIME" >= "TURNOFFCELLSTRTIME". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TURNOFFCELLSTRTIME Dyn. Turning Off Cell Start Time BSC6900 SET GCELLDYNTURNOFF(Optional) Start time of dynmatically disabling cells, that is, from the time, cells are allowed to be disabled. GBFD-111610Dynamic Cell Power Off Compound Type HOUR, MINUTE 00:00~23:59 None None None Cell This parameter is valid only when "TURNOFFENABLE" is set to ENABLE. The following condition must be met: "TURNOFFCELLSTPTIME" >= "TURNOFFCELLSTRTIME". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TURNOFFENABLE Enable Turning Off Cell BSC6900 SET GCELLDYNTURNOFF(Mandatory) Whether the cell can be disabled. GBFD-111610Dynamic Cell Power Off Enumeration Type DISABLE(Disable), ENABLE(Enable) DISABLE, ENABLE None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TURNONCELLLOADTHRD Dyn. Turning On Cell Load Threshold BSC6900 SET GCELLDYNTURNOFF(Optional) When the same coverage cell load of a cell that can be disabled always reaches the threshold, enable the cells that are disabled. GBFD-111610Dynamic Cell Power Off Interval Type 0~100 0~100 per cent None 80 Cell This parameter is valid only when "TURNOFFENABLE" is set to ENABLE. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TUTHD Temperature Alarm Upper Threshold BSC6900 SET BTSAPMUBP(Optional) Temperature alarm upper threshold. If the temperature of the battery is higher than the value of this parameter, an alarm indicating the abnormal temperature is reported.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. GBFD-111202O&M of BTS Interval Type 40~79 40~79 degree Celsius None 50 BTS The value of this parameter must be smaller than "Temperature Alarm Lower Threshold". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TUTHD Temperature Alarm Upper Threshold BSC6900 SET BTSDHEUBP(Optional) Temperature upper threshold of the cabinet. When the cabinet temperature is higher than this parameter, an alarm indicating the abnormal cabinet temperature is reported.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. GBFD-111202O&M of BTS Interval Type -99~99 -99~99 degree Celsius None 68 BTS The value of this parameter must be at least two degrees greater than "Temperature Alarm Lower Threshold". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TWFCMCHIDLE TWF_CMCH_IDLE BSC6900 ADD AISSCFG(Optional) Value of the timer for reserving the channels in the observed cell. GBFD-118201Soft-Synchronized Network Interval Type 1~60 1~60 second 5 None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None.
TWFCMTRXIDLE TWF_CMTRX_IDLE BSC6900 ADD AISSCFG(Optional) Value of the timer for reserving the TRXs in the observed cell. GBFD-118201Soft-Synchronized Network Interval Type 1~60 1~60 second 10 None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None.
TWFCSCHIDLE TWF_CSCH_IDLE BSC6900 ADD AISSCFG(Optional) Value of the timer for reserving the TCHFs in the serving cell. GBFD-118201Soft-Synchronized Network Interval Type 1~60 1~60 second 5 None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None.
TWFRRMRSP TWF_RRM_RSP BSC6900 ADD AISSCFG(Optional) Value of the timer for waiting for the response to information collection. GBFD-118201Soft-Synchronized Network Interval Type 1~60 1~60 min 10 None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None.
TWFSEEKMS TWF_SEEK_MS BSC6900 ADD AISSCFG(Optional) Value of the timer for searching for the MS. GBFD-118201Soft-Synchronized Network Interval Type 1~60 1~60 min 5 None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None.
TWFSYNCACK TWF_SYNC_ACK BSC6900 ADD AISSCFG(Optional) Value of the timer for activating the reserved resources of the BTS. GBFD-118201Soft-Synchronized Network Interval Type 1~60 1~60 second 5 None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None.
TWFSYNCRPT TWF_SYNC_RPT BSC6900 ADD AISSCFG(Optional) Value of the timer for waiting for the synchronization report from the BTS. GBFD-118201Soft-Synchronized Network Interval Type 1~60 1~60 second 5 None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None.
TX TX-integer BSC6900 SET GCELLIDLEBASIC(Optional) Tx-integer (T for short). This parameter specifies the number of timeslots between two transmissions when an MS sends multiple consecutive channel requests.The access algorithm is defined in GSM Rec. 04.08 to reduce the collisions on the RACH and improve the efficiency of the RACH. The algorithm specifies three parameters: Tx-integer (T for short), maximum number of retransmissions (RET), and S related to channel combination.This parameter works with the configuration of the CCCH to determine the parameter S. The relations between this parameter and the configuration of the CCCH are as follows:When this parameter is set to 3, 8, 14, or 50, S is 55 if the CCCH and SDCCH do not share a physical channel.When this parameter is set to 3, 8, 14, or 50, S is 41 if the CCCH and SDCCH share a physical channel.When this parameter is set to 4, 9, or 6, S is 76 if the CCCH and SDCCH do not share a physical channel.When this parameter is set to 4, 9, or 6, S is 52 if the CCCH and SDCCH share a physical channel.When GBFD-111003Radio Common Channel Management Enumeration Type TX_3(3), TX_4(4), TX_5(5), TX_6(6), TX_7(7), TX_8(8), TX_9(9), TX_10(10), TX_11(11), TX_12(12), TX_14(14), TX_16(16), TX_20(20), TX_25(25), TX_32(32), TX_50(50) TX_3, TX_4, TX_5, TX_6, TX_7, TX_8, TX_9, TX_10, TX_11, TX_12, TX_14, TX_16, TX_20, TX_25, TX_32, TX_50 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TXBW forward bandwidth BSC6900 ADD IPPATH(Mandatory) Transmit bandwidth of IP path None None Interval Type 1~3000000 1~3000000 kbit/s None None IP path None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TxBw Forward Bandwidth BSC6900 ADD RSCGRP(Mandatory) Transmit bandwidth. The parameter is valid when the " transmission resource group type " is ATM or " transmission resource group type " is IP and the " bandwidth mode " is FULL_DUPLEX. None None Interval Type 0~4000000 0~4000000 kbit/s None None Transmission resource group When "GRPT" in "ADD RSCGRP" is set to ATM or "BWMODE" is set to FULL_DUPLEX, this parameter is valid;The sum of "TxBw" and "RxBw" in "ADD RSCGRP" of upper class RSCGRP can not less than the "TxBw" and "AllBw" in "ADD RSCGRP"of lower class RSCGRP;The "TxBw" in "ADD RSCGRP" of upper class RSCGRP can not less than the "TxBw" in "ADD RSCGRP" of lower class RSCGRP, and the "RxBw" in "ADD RSCGRP" of upper class RSCGRP can not less than the "RxBw" in "ADD RSCGRP" of lower class RSCGRP. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TXINT Interval of send[ms] BSC6900 PING IP(Optional) Indicates the interval between the two sent PING packets None None Interval Type 200~10000 200~10000 ms 500 500 Ethernet port None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
TXINT TX_INT BSC6900 SET GCELLPRACH(Optional) Extension transmission timeslots of random access. This parameter determines the interval of sending another channel request after the MS fails to request a channel. GBFD-119110Access Enumeration Type T_2(2), T_3(3), T_4(4), T_5(5), T_6(6), T_7(7), T_8(8), T_9(9), T_10(10), T_12(12), T_14(14), T_16(16), T_20(20), T_25(25), T_32(32), T_50(50) T_2, T_3, T_4, T_5, T_6, T_7, T_8, T_9, T_10, T_12, T_14, T_16, T_20, T_25, T_32, T_50 None None T_20 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TYPE Subrack Type BSC6900 ADD SUBRACK(Mandatory) Type of the subrack MRFD-210301Configuration Management Enumeration Type EPS, TCS EPS, TCS None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TYPE Finish Type BSC6900 RUN BATCHFILE(Mandatory) Explanation of the finish type of the batch commands1. ANY_ERR_RETURN: If there is a command whose execution fails, the execution of the batch commands is stopped and the execution of the file fails.2. ALL_END_RETURN: If all commands in the batch file are executed in one operation, the execution of the file succeeds no matter whether there is execution failure in the process. GBFD-111203O&M of BSC Enumeration Type ANY_ERR_RETURN(Stop at error), ALL_END_RETURN(Stop at end) ANY_ERR_RETURN, ALL_END_RETURN None None ANY_ERR_RETURN RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TYPE Information Type BSC6900 SET FACFG(Mandatory) The information type to be set. MRFD-210304Faulty Management Enumeration Type START_TIME_LONG, FA_PERIOD, FAULT_AUTO_RESTORE, LOG_SWITCH, PIU_FAULT_RESTORE, PIU_RESTORE_TIMES, FAULT_CELL_RATE, FAULT_NODEB_NUM START_TIME_LONG/FA_PERIOD/FAULT_AUTO_RESTORE/LOG_SWITCH/PIU_FAULT_RESTORE/PIU_RESTORE_TIMES/FAULT_CELL_RATE/FAULT_NODEB_NUM None None None None None Read & Write Not involved Not involved Not involved None
TYPE Freq. Band BSC6900 ADD GCELL(Mandatory) This parameter specifies the frequency band of new cells. Each new cell can be allocated frequencies of only one frequency band. Once the frequency band is selected, it cannot be changed.GSM900: The cell supports GSM900 frequency band.DCS1800: The cell supports DCS1800 frequency band.GSM900_DCS1800: The cell supports GSM900 and DCS1800 frequency bands.GSM850: The cell supports GSM850 frequency band.GSM850_DCS1800: The cell supports GSM850 and DCS1800 frequency bands.PCS1900: The cell supports PCS1900 frequency band.GSM850_PCS1900: The cell supports GSM850 and PCS1900 frequency bands. GBFD-110101Frequency Band Enumeration Type GSM900, DCS1800, GSM900_DCS1800, GSM850, PCS1900, GSM850_1800, GSM850_1900 GSM900, DCS1800, GSM900_DCS1800, GSM850, PCS1900, GSM850_1800, GSM850_1900 None None None Cell None Read & Write Not involved Not involved Not involved The value of this parameter cannot be changed.
TYPE PCU Type BSC6900 SET BSCPCUTYPE(Mandatory) Type of the PCU. GBFD-114101GPRS Enumeration Type OUTER(Outer PCU), INNER(Inner PCU) OUTER, INNER None None None BSC None Read & Write Y BSC6900 Less than 30 minutes The modified parameter takes effect after the BSC is reset.
TYPE Cell Type BSC6900 ADD GCELLQUICKSETUP(Mandatory) Cell type. Currently, the fast BTS construction is available for only GSM900 and DCS1800 cells. GBFD-113201Concentric Cell Enumeration Type GSM900(GSM900), DCS1800(DCS1800) GSM900, DCS1800 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TYPE Freq. Band BSC6900 ADD BTSAUTOPLAN(Mandatory) Frequency band to which the newly added cell belongs. Only one frequency band can be selected as the frequency band of each new cell and cannot be changed after the selection. To modify the frequency band of the new cell, you must delete the cell and then add it again. GBFD-510701Compact BTS Automatic Configuration and Planning Enumeration Type GSM900, DCS1800, GSM850, PCS1900 GSM900, DCS1800, GSM850, PCS1900 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
TYPE Cabinet Type BSC6900 ADD BTSCABINET(Optional) Type of a cabinet GBFD-111202O&M of BTS Enumeration Type BTS30(BTS30), BTS312(BTS312), BTS3001C(BTS3001C), BTS3001CP(BTS3001CP), BTS3002C(BTS3002C), BTS3012A(BTS3012A), BTS3006A(BTS3006A), BTS3012(BTS3012), BTS3006C(BTS3006C), BTS3002E(BTS3002E), BTS3012AE(BTS3012AE), BTS3012_II(BTS3012 II), DBS3900_GSM(DBS3900 GSM), BTS3900_GSM(BTS3900 GSM), BTS3900A_GSM(BTS3900A GSM), DBS3036(DBS3036), BTS3036(BTS3036), BTS3036A(BTS3036A), BTS3900B_GSM(BTS3900B GSM), BTS3900E_GSM(BTS3900E GSM), BTS3900_GSM_6RFC(BTS3900 GSM 6RFC), BTS3900A_GSM_6RFC(BTS3900A GSM 6RFC), BTS3036_6RFC(BTS3036 6RFC), BTS3036A_6RFC(BTS3036A 6RFC), APM30(APM30), TMC(TMC), BBC(BBC), APM100(APM100), APM200(APM200), PS4890(PS4890), OMB(OMB), RFC-6(RFC-6), BTS3900(BTS3900), BTS3900L(BTS3900L), BTS3900AL(BTS3900AL), BTS3900AS(BTS3900AS), BTS3900B(BTS3900B), BTS3900E(BTS3900E), VIRTUAL(VIRTUAL) BTS30, BTS312, BTS3001C, BTS3001CP, BTS3002C, BTS3012A, BTS3006A, BTS3012, BTS3006C, BTS3002E, BTS3012AE, BTS3012_II, DBS3900_GSM, BTS3900_GSM, BTS3900A_GSM, DBS3036, BTS3036, BTS3036A, BTS3900B_GSM, BTS3900E_GSM, BTS3900_GSM_6RFC, BTS3900A_GSM_6RFC, BTS3036_6RFC, BTS3036A_6RFC, APM30, TMC, BBC, APM100, APM200, PS4890, OMB, RFC-6, BTS3900, BTS3900L, BTS3900AL, BTS3900AS, BTS3900B, BTS3900E, VIRTUAL None None None BTS The value range of this parameter varies with BTS type. Different types of BTSs support different types of cabinets. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
U0GEN Up0 Power Attenuation Factor BSC6900 SET BTSANTFEEDERCONNECT(Optional) Power attenuation factor of uplink tributary 0 GBFD-111202O&M of BTS Interval Type 0~15 0~15 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
U0TOW Up0 Tower-Top Amplifier Flag BSC6900 SET BTSANTFEEDERCONNECT(Optional) Whether there is a TMA on uplink tributary 0 GBFD-111202O&M of BTS Enumeration Type NO(NO), YES(YES) NO, YES None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
U0TRX Up0 Link No. BSC6900 SET BTSANTFEEDERCONNECT(Optional) Index of uplink tributary 0. Each uplink tributary can be configured with a maximum of 12 TRXs. This parameter indicates the serial number of a TRX on the uplink tributary. GBFD-111202O&M of BTS Enumeration Type 1(1), 2(2), 3(3), 4(4), 5(5), 6(6), 7(7), 8(8), 9(9), 10(10), 11(11), 12(12) 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
U0TRXBPN Up0 TRX Board Pass No. BSC6900 SET BTSANTFEEDERCONNECT(Optional) TRX board pass number connected to uplink tributary 0 GBFD-111202O&M of BTS Interval Type 0~1,255 0~1, 255 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
U0TRXSN Up0 TRX Slot No. BSC6900 SET BTSANTFEEDERCONNECT(Optional) Number of the slot where the TRX board that connects to uplink tributary 0 is located GBFD-111202O&M of BTS Interval Type 0~23,255 0~23, 255 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
U0TRXSRN Up0 TRX Subrack No. BSC6900 SET BTSANTFEEDERCONNECT(Optional) Number of the subrack where the TRX board that connects to uplink tributary 0 is located GBFD-111202O&M of BTS Interval Type 0~53,255 0~53, 255 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
U1GEN Up1 Power Attenuation Factor BSC6900 SET BTSANTFEEDERCONNECT(Optional) Power attenuation factor of uplink tributary 1 GBFD-111202O&M of BTS Interval Type 0~15 0~15 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
U1TOW Up1 Tower-Top Amplifier Flag BSC6900 SET BTSANTFEEDERCONNECT(Optional) Whether there is a TMA on uplink tributary 1 None None Enumeration Type NO(NO), YES(YES) NO, YES None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
U1TRX Up1 Link No. BSC6900 SET BTSANTFEEDERCONNECT(Optional) Index of uplink tributary 1. Each uplink tributary can connect to a maximum of 12 TRXs. This parameter indicates the serial number of a TRX on the uplink tributary. None None Enumeration Type 1(1), 2(2), 3(3), 4(4), 5(5), 6(6), 7(7), 8(8), 9(9), 10(10), 11(11), 12(12) 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
U1TRXBPN Up1 TRX Board Pass No. BSC6900 SET BTSANTFEEDERCONNECT(Optional) TRX board pass number connected to uplink tributary 1 GBFD-111202O&M of BTS Interval Type 0~1,255 0~1, 255 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
U1TRXSN Up1 TRX Slot No. BSC6900 SET BTSANTFEEDERCONNECT(Optional) Number of the slot where the TRX board that connects to uplink tributary 1 is located GBFD-111202O&M of BTS Interval Type 0~23,255 0~23, 255 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
U1TRXSRN Up1 TRX Subrack No. BSC6900 SET BTSANTFEEDERCONNECT(Optional) Number of the subrack where the TRX board that connects to uplink tributary 1 is located GBFD-111202O&M of BTS Interval Type 0~53,255 0~53, 255 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ucCSPrefCallReestPrio CS Preferred Call Reestablish Priority BSC6900 SET CSABISCONGCTRL(Optional) Service priority of call reestablishment when CS services are preferred. This parameter is used for the flow control in the case of Abis over IP/HDLC. GBFD-118601Abis over IP Interval Type 0~15 0~15 None None 6 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ucCSPrefCSEmergCallPrio CS Preferred CS Emergency Call Priority BSC6900 SET CSABISCONGCTRL(Optional) Service priority of the CS emergency call when CS services are preferred. This parameter is used for the flow control in the case of Abis over IP/HDLC. GBFD-118601Abis over IP Interval Type 0~15 0~15 None None 0 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ucCSPrefCSOrgCallPrio CS Preferred CS MOC Priority BSC6900 SET CSABISCONGCTRL(Optional) Service priority of the CS MS-originated call when CS services are preferred. This parameter is used for the flow control in the case of Abis over IP/HDLC. GBFD-118601Abis over IP Interval Type 0~15 0~15 None None 1 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ucCSPrefCSTermCallPrio CS Preferred CS MTC Priority BSC6900 SET CSABISCONGCTRL(Optional) Service priority of the CS MS-terminated call when CS services are preferred. This parameter is used for the flow control in the case of Abis over IP/HDLC. GBFD-118601Abis over IP Interval Type 0~15 0~15 None None 1 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ucCSPrefInBscHoPrio CS Preferred Into-BSC HO Priority BSC6900 SET CSABISCONGCTRL(Optional) Service priority of the incoming BSC handover when CS services are preferred. This parameter is used for the flow control in the case of Abis over IP/HDLC. GBFD-118601Abis over IP Interval Type 0~15 0~15 None None 10 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ucCSPrefIntraBscHoPrio CS Preferred Intra-BSC HO Priority BSC6900 SET CSABISCONGCTRL(Optional) Service priority of the intra-BSC handover when CS services are preferred. This parameter is used for the flow control in the case of Abis over IP/HDLC. GBFD-118601Abis over IP Interval Type 0~15 0~15 None None 3 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ucCSPrefOtherPrio CS Preferred Other Service Priority BSC6900 SET CSABISCONGCTRL(Optional) Priority of other services when CS services are preferred. This parameter is used for the flow control in the case of Abis over IP/HDLC. GBFD-118601Abis over IP Interval Type 0~15 0~15 None None 15 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ucCSPrefPSPrio CS Preferred PS Priority BSC6900 SET CSABISCONGCTRL(Optional) PS service priority when CS services are preferred. This parameter is used for the flow control in the case of Abis over IP/HDLC. GBFD-118601Abis over IP Interval Type 0~15 0~15 None None 5 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved If this parameter is set to 0, the emergency call may be affected.
ucCSPrefSupplePrio CS Preferred Supplement Priority BSC6900 SET CSABISCONGCTRL(Optional) Priority of supplementary services when CS services are preferred. This parameter is used for the flow control in the case of Abis over IP/HDLC. GBFD-118601Abis over IP Interval Type 0~15 0~15 None None 15 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ucCSPrefVBSPrio CS Preferred VBS Priority BSC6900 SET CSABISCONGCTRL(Optional) VBS service priority when CS services are preferred. This parameter is used for the flow control in the case of Abis over IP/HDLC. GBFD-118601Abis over IP Interval Type 0~15 0~15 None None 13 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ucCSPrefVGCSPrio CS Preferred VGCS Priority BSC6900 SET CSABISCONGCTRL(Optional) VGCS service priority when CS services are preferred. This parameter is used for the flow control in the case of Abis over IP/HDLC. GBFD-118601Abis over IP Interval Type 0~15 0~15 None None 13 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ucCtrlOfCicIE Controlling of CIC IE In BSS Map Messages BSC6900 SET MSGSOFTPARA(Optional) In A over IP, if the parameter is set to ON, the circuit IE in the A interface extended signaling must be processed in the same way as that in A over non-IP. Otherwise, the A interface extended signaling cannot carry circuit-type IE. GBFD-118602A over IP Enumeration Type OFF(Off), ON(On) OFF, ON None OFF OFF MSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
UCISRAIFAULT Rai Alarm Switch BSC6900 SET OTHSOFTPARA(Optional) Whether the BSC selects the TCHs on the link that reports an RAI alarm. GBFD-111005Enhanced Channel Assignment Algorithm Enumeration Type NO(No), YES(Yes)NO, YES None None NO BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved When RAI alarms occur on the E1 link, services cannot be assigned again by default. After the switch is enabled, services can be assigned, but single-pass may occur on the ongoing services.
ucPSPrefCallReestPrio PS Preferred Call Reestablish Service Priority BSC6900 SET PSPREFABISCONGCTRL(Optional) Reestablish service priority of a PS preferred call. GBFD-118601Abis over IP Interval Type 0~15 0~15 None None 6 BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ucPSPrefCSEmergCallPrio PS Preferred CS Emergency Call Service Priority BSC6900 SET PSPREFABISCONGCTRL(Optional) CS emergency call service priority of a PS preferred call. GBFD-118601Abis over IP Interval Type 0~15 0~15 None None 0 BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ucPSPrefCSOrgCallPrio PS Preferred CS Original Call Service Priority BSC6900 SET PSPREFABISCONGCTRL(Optional) CS original call service priority of a PS preferred call. GBFD-118601Abis over IP Interval Type 0~15 0~15 None None 1 BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ucPSPrefCSTermCallPrio PS Preferred CS Terminated Call Service Priority BSC6900 SET PSPREFABISCONGCTRL(Optional) CS terminated call service priority of a PS preferred call. GBFD-118601Abis over IP Interval Type 0~15 0~15 None None 1 BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ucPSPrefInBscHoPrio PS Preferred In Handover Service Priority BSC6900 SET PSPREFABISCONGCTRL(Optional) BSC handover service priority of a PS preferred call. GBFD-118601Abis over IP Interval Type 0~15 0~15 None None 10 BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ucPSPrefIntraBscHoPrio PS Preferred Intra Handover Service Priority BSC6900 SET PSPREFABISCONGCTRL(Optional) BSC intra handover service priority of a PS preferred call. GBFD-118601Abis over IP Interval Type 0~15 0~15 None None 3 BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ucPSPrefOtherPrio PS Preferred Other Service Priority BSC6900 SET PSPREFABISCONGCTRL(Optional) Other service priority of a PS preferred call. GBFD-118601Abis over IP Interval Type 0~15 0~15 None None 15 BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ucPSPrefPSPrio PS Preferred PS Service Priority BSC6900 SET PSPREFABISCONGCTRL(Optional) PS service priority of a PS preferred call. GBFD-118601Abis over IP Interval Type 0~15 0~15 None None 1 BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ucPSPrefSupplePrio PS Preferred Supplement Service Priority BSC6900 SET PSPREFABISCONGCTRL(Optional) Supplement service priority of a PS preferred call. GBFD-118601Abis over IP Interval Type 0~15 0~15 None None 15 BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ucPSPrefVBSPrio PS Preferred VBS Service Priority BSC6900 SET PSPREFABISCONGCTRL(Optional) VBS service priority of a PS preferred call. GBFD-118601Abis over IP Interval Type 0~15 0~15 None None 13 BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ucPSPrefVGCSPrio PS Preferred VGCS Service Priority BSC6900 SET PSPREFABISCONGCTRL(Optional) VGCS service priority of a PS preferred call. GBFD-118601Abis over IP Interval Type 0~15 0~15 None None 13 BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ucSpeechVerOptiInHo Speech Version Chang Optim in Handover BSC6900 SET AITFOTHPARA(Optional) In case of intra-BSC, if this parameter is set to ON, the same channel type and voice version as those of the original channel are selected. GBFD-118602A over IP Enumeration Type OFF(Off), ON(On) OFF, ON None ON ON MSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
UDPMUXMODRECV Receive UDP MUX Mode BSC6900 ADD IPMUX(Optional) Indicates the UDP MUX mode of the receiving party. If the UDP MUX mode is not supported, it indicates the receiving party does not support the UDP MUX. The mode without supporting the function of compressing the RTP header indicates the receiving party supports the UDP MUX RTP header without supporting the function of compressing the RTP header. The mode with the function of compressing the RTP header indicates the receiving party supports the UDP MUX RTP header and the function of compressing the RTP header. GBFD-118604GBFD-118610 Abis MUXUDP MUX for A Transmission Enumeration Type MUXCLOSE, NORTPCOMP, RTPCOMP MUXCLOSE, NORTPCOMP, RTPCOMP None MUXCLOSE None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The adjacent node ID must be configured.
UDPMUXMODSEND Sender UDP MUX Mode BSC6900 ADD IPMUX(Optional) Indicates the UDP MUX mode of the receiving party. If the UDP MUX mode is not supported, it indicates the receiving party does not support the UDP MUX. The mode without supporting the function of compressing the RTP header indicates the receiving party supports the UDP MUX RTP header without supporting the function of compressing the RTP header. The mode with the function of compressing the RTP header indicates the receiving party supports the UDP MUX RTP header and the function of compressing the RTP header. GBFD-118604GBFD-118610 Abis MUXUDP MUX for A Transmission Enumeration Type MUXCLOSE, NORTPCOMP, RTPCOMP MUXCLOSE, NORTPCOMP, RTPCOMP None MUXCLOSE None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
UDPPN Local UDP Port No. BSC6900 ADD NSVLLOCAL(Mandatory) UDP port number of the local NSVL. GBFD-118603Gb over IP Interval Type 1214~2001,2005~3783,3785~4783,4785~65000 1214~2001, 2005~3783, 3785~4783, 4785~65000 None None None NSE None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
UDPPN Remote UDP Port No. BSC6900 ADD NSVLREMOTE(Mandatory) UDP port number of the remote NSVL. GBFD-118603Gb over IP Interval Type 0~65535 0~65535 None None None NSE None Read & Write Y NSE Services are interrupted unless the NSVL configuration is the same as the SGSN configuration at the BSC. None
UG Operator Level BSC6900 ADD OP(Optional)Group to which the operator belongs. This parameter is used to limit the right of the operator. GBFD-111203MRFD-210305 O&M of BSCSecurity Management Enumeration Type Administrators(Administrators), Operators(Operators), Users(Users), Guests(Guests), Customs(Customs) Administrators, Operators, Users, Guests, Customs None Guests Guests RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
UHUMTHD Upper Humidity Threshold BSC6900 SET BTSEXD(Optional) Upper humidity threshold for the environment alarm box to report an alarm indicating that the ambient humidity is too high. If the ambient humidity of the BTS is higher than this threshold, the environment alarm box reports the alarm.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. GBFD-111202O&M of BTS Interval Type 0~99 0~99 None None 80 BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The setting of this parameter must be greater than "LHUMTHD".
UIC UIC BSC6900 SET GCELLGSMR(Optional) Used to identify the uplink access message from the MS. The value 64 is invalid. GBFD-510301GBFD-510302 Public Voice Group Call ServicePublic Voice Broadcast Service Interval Type 0~64 0~64 None None 64 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
UINTTIME Unit time[ms] BSC6900 STR E1T1TST(Optional) Unit time for the error code ratio test None None Interval Type 300~1000 300~1000 ms 1000 1000 E1/T1 port None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
UL Upper Limit BSC6900 SET ALMPORT(Optional) Upper limit for triggering an alarm MRFD-210304Faulty Management String Type None 0~9 Characters None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
UL Upper Limit BSC6900 SET BTSENVALMPORT(Optional) Upper limit of the alarm. This parameter is valid to the analog port. MRFD-210304Faulty Management String Type None 1~8 characters None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ULADJPRD PwrCtrlULAdjPeriod BSC6900 SET GCELLPWR3(Optional) Minimum interval between two consecutive uplink power control commands. GBFD-117601HUAWEI III Power Control Algorithm Interval Type 0~255 0~255, step:480 for TCH and 470 for SDCCH ms None 3 Cell This parameter is valid only when "PWRCTRLSW" in "SET GCELLPWRBASIC" is set to PWR3. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ULAFSREXQUALHIGHTHRED ULAFSRexQualHighThred BSC6900 SET GCELLPWR3(Optional) Current call is an AMR full-rate call, and when the uplink receive quality is greater than the threshold, Huawei III power control is performed. GBFD-117601HUAWEI III Power Control Algorithm Interval Type 1~30 1~30 dB None 16 Cell This parameter is valid only when "PWRCTRLSW" in "SET GCELLPWRBASIC" is set to PWR3. The following condition must be met: "ULAFSREXQUALHIGHTHRED" >= "ULAFSREXQUALLOWTHRED". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ULAFSREXQUALLOWTHRED ULAFSRexQualLowThred BSC6900 SET GCELLPWR3(Optional) Current call is an AMR full-rate call, and when the uplink receive quality is lower than the threshold, Huawei III power control is performed. GBFD-117601HUAWEI III Power Control Algorithm Interval Type 1~30 1~30 dB None 12 Cell This parameter is valid only when "PWRCTRLSW" in "SET GCELLPWRBASIC" is set to PWR3. The following condition must be met: "ULAFSREXQUALHIGHTHRED" >= "ULAFSREXQUALLOWTHRED". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ULAHSREXQUALHIGHTHRED ULAHSRexQualHighThred BSC6900 SET GCELLPWR3(Optional) Current call is an AMR half-rate call, and when the uplink receive quality is greater than the threshold, Huawei III power control is performed. GBFD-117601HUAWEI III Power Control Algorithm Interval Type 1~30 1~30 dB None 16 Cell This parameter is valid only when "PWRCTRLSW" in "SET GCELLPWRBASIC" is set to PWR3. The following condition must be met: "ULAHSREXQUALHIGHTHRED" >= "ULAHSREXQUALLOWTHRED". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ULAHSREXQUALLOWTHRED ULAHSRexQualLowThred BSC6900 SET GCELLPWR3(Optional) Current call is an AMR half-rate call, and when the uplink receive quality is lower than the threshold, Huawei III power control is performed. GBFD-117601HUAWEI III Power Control Algorithm Interval Type 1~30 1~30 dB None 12 Cell This parameter is valid only when "PWRCTRLSW" in "SET GCELLPWRBASIC" is set to PWR3. The following condition must be met: "ULAHSREXQUALHIGHTHRED" >= "ULAHSREXQUALLOWTHRED". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ULBQLASTTIME UL BQ HO last time BSC6900 SET GCELLHOBASIC(Optional) The P/N criterion must be met for triggering a UL BQ handover. That is, the UL BQ handover can be triggered only if P measurement reports among N measurement reports meet the triggering conditions. This parameter corresponds to P in the P/N criterion. GBFD-510501HUAWEI II Handover Interval Type 1~8 1~8, step:0.5 s None 1 Cell This parameter is valid only when "BETTERCELLHOEN" is set to YES and "HOCTRLSWITCH" is set to HOALGORITHM2. The following condition must be met: "ULBQSTATTIME" >= "ULBQLASTTIME". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ULBQSTATTIME UL BQ HO static time BSC6900 SET GCELLHOBASIC(Optional) The P/N criterion must be met for triggering a UL BQ handover. That is, the UL BQ handover can be triggered only if P measurement reports among N measurement reports meet the triggering conditions. This parameter corresponds to N in the P/N criterion. GBFD-510501HUAWEI II Handover Interval Type 1~8 1~8, step:0.5 s None 1 Cell This parameter is valid only when "BETTERCELLHOEN" is set to YES and "HOCTRLSWITCH" is set to HOALGORITHM2. The following condition must be met: "ULBQSTATTIME" >= "ULBQLASTTIME". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ULCOEFFICIENTTSRAPIDADJ Fast UL Priority Decision Threshold BSC6900 SET BSCPSSOFTPARA(Optional) If the ratio of uplink flow to downlink flow is greater than or equal to the value of this parameter during the fast flux measurement, the uplink services takes priority. GBFD-119501Adaptive Adjustment of Uplink and Downlink Channels Interval Type 1~255 1~255 None None 5 BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved If this parameter is set to a small value, the detection of service type is sensitive and may lead to ping-pong switching between different services.
ULDATAFWDTMR Timer for UL Data Forward BSC6900 SET GCELLTMR(Optional) Duration for uplink data transmission on the original channel if the TC resources are changed before and after the handover GBFD-111203O&M of BSC Interval Type 0~240 0~240 ms None In Abis over TDM transmission, the recommended value is 180; in Abis over IP transmission, the recommended value is 200. Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ulDlAckFreq RRBP Frequency for GPRS Downlink TBF BSC6900 SET BSCPSSOFTPARA(Optional) Number of downlink GRPS TBF RLC blocks sent before an acknowledgement is required. GBFD-119105RLC Mode Interval Type 1~64 1~64 None None 15 BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ULEDGETHRES Edge HO UL RX_LEV Threshold BSC6900 SET GCELLHOBASIC(Optional) If the UL receive level remains lower than the "Edge HO UL RX_LEV Threshold" for a period, the edge handover is triggered. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 0~63 0~63 dB None 10 Cell This parameter is valid when "FRINGEHOEN" is set to YES or "RXQCKFALLHOEN" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ulEgprsDlAckFreq RRBP Frequency for EGPRS Downlink TBF BSC6900 SET BSCPSSOFTPARA(Optional) Number of downlink EGPRS TBF RLC blocks before the RRBP is set to 1. GBFD-119105RLC Mode Interval Type 1~64 1~64 None None 20 BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ulEgprsUlAckFreq ACK Frequency for EGPRS Uplink TBF BSC6900 SET BSCPSSOFTPARA(Optional) Period of acknowledging the EGPRS TBF RLC uplink data block. GBFD-119105RLC Mode Interval Type 1~64 1~64 None None 32 BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ULFILTADJFACTOR III UL Filter Adjust Factor BSC6900 SET GCELLPWR3(Optional) Filter adjustment factor for uplink power control. If this parameter is set to a large value, the filtered values become smooth, thus reducing the impact of poor measurement reports on the filtered values. If this parameter is set to a small value, the filter values are close to the actual ones and thus the power control speed is increased. GBFD-117601HUAWEI III Power Control Algorithm Interval Type 1~10 1~10 None None 3 Cell This parameter is valid only when "PWRCTRLOPTIMIZEDEN" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ULFSREXQUALHIGHTHRED ULFSRexQualHighThred BSC6900 SET GCELLPWR3(Optional) Current call is a full-rate call, and when the uplink receive quality is greater than the threshold, Huawei III power control is performed. GBFD-117601HUAWEI III Power Control Algorithm Interval Type 1~30 1~30 dB None 22 Cell This parameter is valid only when "PWRCTRLSW" in "SET GCELLPWRBASIC" is set to PWR3. The following condition must be met: "ULFSREXQUALHIGHTHRED" >= "ULFSREXQUALLOWTHRED". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ULFSREXQUALLOWTHRED ULFSRexQualLowThred BSC6900 SET GCELLPWR3(Optional) Current call is a full-rate call, and when the uplink receive quality is lower than the threshold, Huawei III power control is performed. GBFD-117601HUAWEI III Power Control Algorithm Interval Type 1~30 1~30 dB None 16 Cell This parameter is valid only when "PWRCTRLSW" in "SET GCELLPWRBASIC" is set to PWR3. The following condition must be met: "ULFSREXQUALHIGHTHRED" >= "ULFSREXQUALLOWTHRED". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ULHSREXQUALHIGHTHRED ULHSRexQualHighThred BSC6900 SET GCELLPWR3(Optional) Current call is a half-rate call, and when the uplink receive quality is greater than the threshold, Huawei III power control is performed. GBFD-117601HUAWEI III Power Control Algorithm Interval Type 1~30 1~30 dB None 18 Cell This parameter is valid only when "PWRCTRLSW" in "SET GCELLPWRBASIC" is set to PWR3. The following condition must be met: "ULHSREXQUALHIGHTHRED" >= "ULHSREXQUALLOWTHRED". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ULHSREXQUALLOWTHRED ULHSRexQualLowThred BSC6900 SET GCELLPWR3(Optional) Current call is a half-rate call, and when the uplink receive quality is lower than the threshold, Huawei III power control is performed. GBFD-117601HUAWEI III Power Control Algorithm Interval Type 1~30 1~30 dB None 18 Cell This parameter is valid only when "PWRCTRLSW" in "SET GCELLPWRBASIC" is set to PWR3. The following condition must be met: "ULHSREXQUALHIGHTHRED" >= "ULHSREXQUALLOWTHRED". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ULHYSTF1 AMR UL Coding Rate adj.hyst1[F] BSC6900 SET GCELLCCAMR(Optional) Based on the RQI in the call measurement report, the BTS and MS automatically adjust the current speech coding rate according to the related algorithm. The coding rate adjustment threshold is the threshold of RQI. The RQI indicates the carrier-to-interference ratio (CIR) of the call. If RQI equals 1, the CIR is 0.5 dB; if RQI equals 2, the CIR is 1 dB; and so forth. Since there are multiple coding rates in the ACS, there is an adjustment threshold and an adjustment hysteresis between the neighboring coding rates. GBFD-115501AMR FR Interval Type 0~15 0~15 None None 2 Cell The setting of this parameter must meet the following condition: "ULTHF1" + "ULHYSTF1" < "ULTHF2" + "ULHYSTF2". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ULHYSTF2 AMR UL Coding Rate adj.hyst2[F] BSC6900 SET GCELLCCAMR(Optional) Based on the RQI in the call measurement report, the BTS and MS automatically adjust the current speech coding rate according to the related algorithm. The coding rate adjustment threshold is the threshold of RQI. The RQI indicates the carrier-to-interference ratio (CIR) of the call. If RQI equals 1, the CIR is 0.5 dB; if RQI equals 2, the CIR is 1 dB; and so forth. Since there are multiple coding rates in the ACS, there is an adjustment threshold and an adjustment hysteresis between the neighboring coding rates. GBFD-115501AMR FR Interval Type 0~15 0~15 None None 3 Cell The setting of this parameter must meet the following condition: "ULTHF2" + "ULHYSTF2" < "ULTHF3" + "ULHYSTF3". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ULHYSTF3 AMR UL Coding Rate adj.hyst3[F] BSC6900 SET GCELLCCAMR(Optional) Based on the RQI in the call measurement report, the BTS and MS automatically adjust the current speech coding rate according to the related algorithm. The coding rate adjustment threshold is the threshold of RQI. The RQI indicates the carrier-to-interference ratio (CIR) of the call. If RQI equals 1, the CIR is 0.5 dB; if RQI equals 2, the CIR is 1 dB; and so forth. Since there are multiple coding rates in the ACS, there is an adjustment threshold and an adjustment hysteresis between the neighboring coding rates. GBFD-115501AMR FR Interval Type 0~15 0~15 None None 3 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ULHYSTH1 AMR UL Coding Rate adj.hyst1[H] BSC6900 SET GCELLCCAMR(Optional) Based on the RQI in the call measurement report, the BTS and MS automatically adjust the current speech coding rate according to the related algorithm. The coding rate adjustment threshold is the threshold of RQI. The RQI indicates the carrier-to-interference ratio (CIR) of the call. If RQI equals 1, the CIR is 0.5 dB; if RQI equals 2, the CIR is 1 dB; and so forth. Since there are multiple coding rates in the ACS, there is an adjustment threshold and an adjustment hysteresis between the neighboring coding rates. GBFD-115502AMR HR Interval Type 0~15 0~15 None None 3 Cell The setting of this parameter must meet the following condition: "ULTHH1" + "ULHYSTH1" < "ULTHH2" + "ULHYSTH2". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ULHYSTH2 AMR UL Coding Rate adj.hyst2[H] BSC6900 SET GCELLCCAMR(Optional) Based on the RQI in the call measurement report, the BTS and MS automatically adjust the current speech coding rate according to the related algorithm. The coding rate adjustment threshold is the threshold of RQI. The RQI indicates the carrier-to-interference ratio (CIR) of the call. If RQI equals 1, the CIR is 0.5 dB; if RQI equals 2, the CIR is 1 dB; and so forth. Since there are multiple coding rates in the ACS, there is an adjustment threshold and an adjustment hysteresis between the neighboring coding rates. GBFD-115502AMR HR Interval Type 0~15 0~15 None None 4 Cell The setting of this parameter must meet the following condition: "ULTHH2" + "ULHYSTH2" < "ULTHH3" + "ULHYSTH3". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ULHYSTH3 AMR UL Coding Rate adj.hyst3[H] BSC6900 SET GCELLCCAMR(Optional) Based on the RQI in the call measurement report, the BTS and MS automatically adjust the current speech coding rate according to the related algorithm. The coding rate adjustment threshold is the threshold of RQI. The RQI indicates the carrier-to-interference ratio (CIR) of the call. If RQI equals 1, the CIR is 0.5 dB; if RQI equals 2, the CIR is 1 dB; and so forth. Since there are multiple coding rates in the ACS, there is an adjustment threshold and an adjustment hysteresis between the neighboring coding rates. GBFD-115502AMR HR Interval Type 0~15 0~15 None None 15 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ULHYSTWB1 AMR UL Coding Rate adj.hyst1[WB] BSC6900 SET GCELLCCAMR(Optional) Based on the RQI in the call measurement report, the BTS and MS automatically adjust the current speech coding rate according to the related algorithm. The coding rate adjustment threshold is the threshold of RQI. The RQI indicates the carrier-to-interference ratio (CIR) of the call. If RQI equals 1, the CIR is 0.5 dB; if RQI equals 2, the CIR is 1 dB; and so forth. Since there are multiple coding rates in the ACS, there is an adjustment threshold and an adjustment hysteresis between the neighboring coding rates. GBFD-115507WB AMR Interval Type 0~15 0~15 None None 2 Cell The setting of this parameter must meet the following condition: "ULTHWB1" + "ULHYSTWB1" < "ULTHWB2" + "ULHYSTWB2". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ULHYSTWB2 AMR UL Coding Rate adj.hyst2[WB] BSC6900 SET GCELLCCAMR(Optional) Based on the RQI in the call measurement report, the BTS and MS automatically adjust the current speech coding rate according to the related algorithm. The coding rate adjustment threshold is the threshold of RQI. The RQI indicates the carrier-to-interference ratio (CIR) of the call. If RQI equals 1, the CIR is 0.5 dB; if RQI equals 2, the CIR is 1 dB; and so forth. Since there are multiple coding rates in the ACS, there is an adjustment threshold and an adjustment hysteresis between the neighboring coding rates. GBFD-115507WB AMR Interval Type 0~15 0~15 None None 2 Cell The setting of this parameter must meet the following condition: "ULTHWB1" + "ULHYSTWB1" < "ULTHWB2" + "ULHYSTWB2". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
UlLdrThrd2GCell 2G Cell UL Basic Congest Thred BSC6900 SET GCELLHOINTERRATLDB(Optional) Threshold of uplink Basic Congestion state in a 2G Cell MRFD-211402MBSC Load Balancing Interval Type 1~100 {1~100} None None None BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ULLEVFILTLEN Filter Length for UL RX_LEV BSC6900 SET GCELLPWR2(Optional) When the network receives measurement reports, in consideration of the accuracy of a single measurement report, the measurement values in certain measurement reports are filtered to represent the radio operating environment. This parameter specifies the number of measurement reports sampled for filtering the uplink signal strength. GBFD-110703Enhanced Power Control Algorithm Interval Type 1~20 1~20, step:480 for TCH and 470 for SDCCH ms None 5 Cell This parameter is valid only when "PWRCTRLSW" in "SET GCELLPWRBASIC" is set to PWR2 and "UPPCEN" in "SET GCELLBASICPARA" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ULMAXDOWNSTEP ULMAXDownStep BSC6900 SET GCELLPWR3(Optional) Maximum permissible adjustment step when the BSC decreases the uplink transmit power. GBFD-117601HUAWEI III Power Control Algorithm Interval Type 1~30 1~30 dB None 8 Cell This parameter is valid only when "PWRCTRLSW" in "SET GCELLPWRBASIC" is set to PWR3. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ULMAXUPSTEP ULMAXUpStep BSC6900 SET GCELLPWR3(Optional) Maximum permissible adjustment step when the BSC increases the uplink transmit power. GBFD-117601HUAWEI III Power Control Algorithm Interval Type 1~30 1~30 dB None 8 Cell This parameter is valid only when "PWRCTRLSW" in "SET GCELLPWRBASIC" is set to PWR3. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
UlOlcThrd2GCell 2G Cell UL Overload Congest Thred BSC6900 SET GCELLHOINTERRATLDB(Optional) Threshold of uplink overload congestion state in a 2G Cell MRFD-211402MBSC Load Balancing Interval Type 1~100 {1~100} None None None BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ULPREDLEND UL MR. Number Predicted BSC6900 SET GCELLPWR2(Optional) After the BSC delivers the power control command, it should wait for a certain period before affirm the effect of the power control. Therefore, the MR that power control decision is based on cannot accurately reflect the radio environment during the power adjustment, but misses the latest changes of the receive level and receive quality of the MS. Thus, the power adjustment is delayed.To compensate the delay of power adjustment, the power control algorithm implements the prediction and filtering function. In other words, the BSC samples several uplink measurement reports, performs weighted filtering, and predicts N measurement reports from the current time onwards in a short period. This parameter determines the number of uplink measurement reports predicted by the BSC. In other words, the value of this parameter equals to the previous number N. GBFD-110703Enhanced Power Control Algorithm Interval Type 0~3 0~3 None None 0 Cell This parameter is valid only when "PWRCTRLSW" in "SET GCELLPWRBASIC" is set to PWR2 and "UPPCEN" in "SET GCELLBASICPARA" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ULQHIGHTHRED UL Qual. Upper Threshold BSC6900 SET GCELLPWRBASIC(Optional) The MS transmit power is decreased only when the quality level of the MS transmit signal is smaller than the value of the parameter. If (the uplink receive level - "MAX Up Adj. PC Value by Qual.]/PARA]) is smaller than "UL RX_LEV Lower Threshold", the MS transmit power is not adjusted. GBFD-110703Enhanced Power Control Algorithm Interval Type 0~7 0~7 None None 0 Cell This parameter is valid only when "PWRCTRLSW" in "SET GCELLPWRBASIC" is set to PWR2. The following condition must be met: "ULQLOWTHRED" >= "ULQHIGHTHRED". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ULQLOWTHRED UL Qual. Lower Threshold BSC6900 SET GCELLPWRBASIC(Optional) The MS transmit power is increased only when the quality level of the MS transmit signal is greater than the value of the parameter. If (the uplink receive level + "MAX Up Adj. PC Value by Qual.]/PARA]) is greater than "UL RX_LEV Upper Threshold", the MS transmit power is not adjusted. GBFD-110703Enhanced Power Control Algorithm Interval Type 0~7 0~7 None None 3 Cell This parameter is valid only when "PWRCTRLSW" in "SET GCELLPWRBASIC" is set to PWR2. The following condition must be met: "ULQLOWTHRED" >= "ULQHIGHTHRED". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ULQUAFILTLEN Filter Length for UL Qual. BSC6900 SET GCELLPWR2(Optional) When the network receives measurement reports, the measurement values in several straight measurement reports are filtered to reflect the radio operating environment for the sake of accuracy. This parameter specifies the number of measurement reports sampled for filtering the uplink signal quality. GBFD-110703Enhanced Power Control Algorithm Interval Type 1~20 1~20, step:480 for TCH and 470 for SDCCH ms None 5 Cell This parameter is valid only when "PWRCTRLSW" in "SET GCELLPWRBASIC" is set to PWR2 and "UPPCEN" in "SET GCELLBASICPARA" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ULQUALBADTRIG UL Qual. Bad Trig Threshold BSC6900 SET GCELLPWR2(Optional) In the case of power control, when the uplink receive quality is not smaller than "UL Qual. Bad Trig Threshold", the actual "UL RX_LEV Upper Threshold" is increased by "UL Qual. Bad UpLEVDiff". GBFD-110703Enhanced Power Control Algorithm Interval Type 0~7 0~7 None None 3 Cell This parameter is valid when "PWRCTRLSW" in the "SET GCELLPWRBASIC" command is set to PWR2. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ULQUALBADUPLEV UL Qual. Bad UpLEVDiff BSC6900 SET GCELLPWR2(Optional) In the case of power control, when the uplink receive quality is not smaller than "UL Qual. Bad Trig Threshold", the actual "UL RX_LEV Upper Threshold" is increased by "UL Qual. Bad UpLEVDiff". GBFD-110703Enhanced Power Control Algorithm Interval Type 0~63 0~63 dB None 5 Cell This parameter is valid when "PWRCTRLSW" in the "SET GCELLPWRBASIC" command is set to PWR2. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ULQUALIMIT UL Qual. Threshold BSC6900 SET GCELLHOEMG(Optional) An emergency handover due to bad quality is triggered when the uplink receive quality is not smaller than "UL Qual. Threshold". GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 0~70 0~70 None None 55 Cell This parameter is valid only when "BQHOEN" in "SET GCELLHOBASIC" is set to YES and "NODLMRHOEN" in "SET GCELLHOEMG" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ULQUALIMITAMRFR UL Qual. Limit for AMR FR BSC6900 SET GCELLAMRQUL(Optional) The value of this parameter corresponds to multiplying quality level 0 to 7 by 10. An emergency handover can be triggered only when the uplink receive quality of the MS is greater than the value of this parameter. GBFD-115501AMR FR Interval Type 0~70 0~70 None None 60 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The setting of this parameter affects the triggering of BQ(Bad Quality) handover of AMR FR calls. If it is set to a smaller value, the uplink BQ handover is easily triggered.
ULQUALIMITAMRHR UL Qual. Limit for AMR HR BSC6900 SET GCELLAMRQUL(Optional) The value of this parameter corresponds to multiplying quality level 0 to 7 by 10. An emergency handover can be triggered only when the uplink receive quality of the MS is greater than the value of this parameter. GBFD-115502AMR HR Interval Type 0~70 0~70 None None 55 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The setting of this parameter affects the triggering of BQ handover of AMR HR calls. If it is set to a smaller value, the uplink BQ handover is easily triggered.
ULREXLEVADJFCTR ULRexLevAdjustFactor BSC6900 SET GCELLPWR3(Optional) Step adjustment ratio of the receive level in the uplink power control GBFD-117601HUAWEI III Power Control Algorithm Interval Type 0~10 0~10 None None 3 Cell This parameter is valid only when "PWRCTRLSW" in "SET GCELLPWRBASIC" is set to PWR3. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ULREXLEVEXPFLTLEN ULRexLevExponentFilterLen BSC6900 SET GCELLPWR3(Optional) When the network receives measurement reports, the measurement values in several straight measurement reports are filtered to reflect the radio operating environment for the sake of accuracy. This parameter specifies the number of measurement reports sampled for exponent filtering of the uplink signal strength. GBFD-117601HUAWEI III Power Control Algorithm Interval Type 0~19 0~19, step:480 for TCH and 470 for SDCCH ms None 3 Cell This parameter is valid only when "PWRCTRLSW" in "SET GCELLPWRBASIC" is set to PWR3. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ULREXLEVHIGHTHRED ULRexLevHighThred BSC6900 SET GCELLPWR3(Optional) When the uplink receive level reaches the threshold, Huawei III power control is performed. GBFD-117601HUAWEI III Power Control Algorithm Interval Type 0~63 0~63 dB None 30 Cell This parameter is valid only when "PWRCTRLSW" in "SET GCELLPWRBASIC" is set to PWR3. The following condition must be met: "ULREXLEVHIGHTHRED" >= "ULREXLEVLOWTHRED". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ULREXLEVLOWTHRED ULRexLevLowThred BSC6900 SET GCELLPWR3(Optional) When the uplink receive level is lower than the threshold, Huawei III power control is performed. GBFD-117601HUAWEI III Power Control Algorithm Interval Type 0~63 0~63 dB None 20 Cell This parameter is valid only when "PWRCTRLSW" in "SET GCELLPWRBASIC" is set to PWR3. The following condition must be met: "ULREXLEVHIGHTHRED" >= "ULREXLEVLOWTHRED". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ULREXLEVSLDWINDOW ULRexLevSlideWindow BSC6900 SET GCELLPWR3(Optional) When the network receives measurement reports, the measurement values in several straight measurement reports are filtered to reflect the radio operating environment for the sake of accuracy. This parameter specifies the number of measurement reports sampled for slide-window filtering of the uplink signal strength. GBFD-117601HUAWEI III Power Control Algorithm Interval Type 1~20 1~20, step:480 for TCH and 470 for SDCCH ms None 1 Cell This parameter is valid only when "PWRCTRLSW" in "SET GCELLPWRBASIC" is set to PWR3. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ULREXQUALADJFCTR ULRexQualAdjustFactor BSC6900 SET GCELLPWR3(Optional) Step adjustment ratio of the receive quality in the uplink power control. GBFD-117601HUAWEI III Power Control Algorithm Interval Type 0~10 0~10 None None 6 Cell This parameter is valid only when "PWRCTRLSW" in "SET GCELLPWRBASIC" is set to PWR3. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ULREXQUALEXPFLTLEN ULRexQualExponentFilterLen BSC6900 SET GCELLPWR3(Optional) When the network receives measurement reports, the measurement values in several straight measurement reports are filtered to reflect the radio operating environment for the sake of accuracy. This parameter specifies the number of measurement reports sampled for exponent filtering of the uplink signal quality. GBFD-117601HUAWEI III Power Control Algorithm Interval Type 0~19 0~19, step:480 for TCH and 470 for SDCCH ms None 3 Cell This parameter is valid only when "PWRCTRLSW" in "SET GCELLPWRBASIC" is set to PWR3. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ULREXQUALSLDWINDOW ULRexQualSlideWindow BSC6900 SET GCELLPWR3(Optional) When the network receives measurement reports, the measurement values in several straight measurement reports are filtered to reflect the radio operating environment for the sake of accuracy. This parameter specifies the number of measurement reports sampled for slide-window filtering of the uplink signal quality. GBFD-117601HUAWEI III Power Control Algorithm Interval Type 1~20 1~20, step:480 for TCH and 470 for SDCCH ms None 1 Cell This parameter is valid only when "PWRCTRLSW" in "SET GCELLPWRBASIC" is set to PWR3. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ULRXLEVPROTECTFACTOR III UL RexLev Protect Factor BSC6900 SET GCELLPWR3(Optional) Signal strength factor for the protective limitation on calculating the uplink power control adjustment step. The calculated step value cannot exceed the step value that is obtained on the basis of the signal strength protection factor and the signal quality protection factor. GBFD-117601HUAWEI III Power Control Algorithm Interval Type 0~100 0~100 None None 6 Cell This parameter is valid only when "PWRCTRLOPTIMIZEDEN" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ULRXQUALPROTECTFACTOR III UL RexQual Protect Factor BSC6900 SET GCELLPWR3(Optional) Signal strength factor for the protective limitation on calculating the uplink power control adjustment step. The calculated step value cannot exceed the step value that is obtained on the basis of the signal strength protection factor and the signal quality protection factor. GBFD-117601HUAWEI III Power Control Algorithm Interval Type 0~100 0~100 None None 75 Cell This parameter is valid only when "PWRCTRLOPTIMIZEDEN" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ULSSHIGHTHRED UL RX_LEV Upper Threshold BSC6900 SET GCELLPWRBASIC(Optional) When the uplink receive level reaches the threshold, Huawei II power control is performed. GBFD-110703Enhanced Power Control Algorithm Interval Type 0~63 0~63 dB None 30 Cell This parameter is valid only when "PWRCTRLSW" in "SET GCELLPWRBASIC" is set to PWR2. The following condition must be met: "ULSSHIGHTHRED" >= "ULSSLOWTHRED". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ULSSLOWTHRED UL RX_LEV Lower Threshold BSC6900 SET GCELLPWRBASIC(Optional) When the uplink receive level is below the threshold, Huawei II power control is performed. GBFD-110703Enhanced Power Control Algorithm Interval Type 0~63 0~63 dB None 18 Cell This parameter is valid only when "PWRCTRLSW" in "SET GCELLPWRBASIC" is set to PWR2. The following condition must be met: "ULSSHIGHTHRED" >= "ULSSLOWTHRED". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ULTHF1 AMR UL Coding Rate adj.th1[F] BSC6900 SET GCELLCCAMR(Optional) Based on the RQI in the call measurement report, the BTS and MS automatically adjust the current speech coding rate according to the related algorithm. The coding rate adjustment threshold is the threshold of RQI. The RQI indicates the carrier-to-interference ratio (CIR) of the call. If RQI equals 1, the CIR is 0.5 dB; if RQI equals 2, the CIR is 1 dB; and so forth. Since there are multiple coding rates in the ACS, there is an adjustment threshold and an adjustment hysteresis between the neighboring coding rates. GBFD-115501AMR FR Interval Type 0~63 0~63 dB None 15 Cell The setting of this parameter must meet the following conditions: "ULTHF1" < "ULTHF2"; "ULTHF1" + "ULHYSTF1" < "ULTHF2" + "ULHYSTF2". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ULTHF2 AMR UL Coding Rate adj.th2[F] BSC6900 SET GCELLCCAMR(Optional) Based on the RQI in the call measurement report, the BTS and MS automatically adjust the current speech coding rate according to the related algorithm. The coding rate adjustment threshold is the threshold of RQI. The RQI indicates the carrier-to-interference ratio (CIR) of the call. If RQI equals 1, the CIR is 0.5 dB; if RQI equals 2, the CIR is 1 dB; and so forth. Since there are multiple coding rates in the ACS, there is an adjustment threshold and an adjustment hysteresis between the neighboring coding rates. GBFD-115501AMR FR Interval Type 0~63 0~63 dB None 19 Cell The setting of this parameter must meet the following conditions: "ULTHF2" < "ULTHF3"; "ULTHF2" + "ULHYSTF2" < "ULTHF3" + "ULHYSTF3". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ULTHF3 AMR UL Coding Rate adj.th3[F] BSC6900 SET GCELLCCAMR(Optional) Based on the RQI in the call measurement report, the BTS and MS automatically adjust the current speech coding rate according to the related algorithm. The coding rate adjustment threshold is the threshold of RQI. The RQI indicates the carrier-to-interference ratio (CIR) of the call. If RQI equals 1, the CIR is 0.5 dB; if RQI equals 2, the CIR is 1 dB; and so forth. Since there are multiple coding rates in the ACS, there is an adjustment threshold and an adjustment hysteresis between the neighboring coding rates. GBFD-115501AMR FR Interval Type 0~63 0~63 dB None 28 Cell The setting of this parameter must meet the following conditions: "ULTHF2" < "ULTHF3"; "ULTHF2" + "ULHYSTF2" < "ULTHF3" + "ULHYSTF3". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ULTHH1 AMR UL Coding Rate adj.th1[H] BSC6900 SET GCELLCCAMR(Optional) Based on the RQI in the call measurement report, the BTS and MS automatically adjust the current speech coding rate according to the related algorithm. The coding rate adjustment threshold is the threshold of RQI. The RQI indicates the carrier-to-interference ratio (CIR) of the call. If RQI equals 1, the CIR is 0.5 dB; if RQI equals 2, the CIR is 1 dB; and so forth. Since there are multiple coding rates in the ACS, there is an adjustment threshold and an adjustment hysteresis between the neighboring coding rates. GBFD-115502AMR HR Interval Type 0~63 0~63 dB None 23 Cell The setting of this parameter must meet the following conditions: "ULTHH1" < "ULTHH2"; "ULTHH1" + "ULHYSTH1" < "ULTHH2" + "ULHYSTH2". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ULTHH2 AMR UL Coding Rate adj.th2[H] BSC6900 SET GCELLCCAMR(Optional) Based on the RQI in the call measurement report, the BTS and MS automatically adjust the current speech coding rate according to the related algorithm. The coding rate adjustment threshold is the threshold of RQI. The RQI indicates the carrier-to-interference ratio (CIR) of the call. If RQI equals 1, the CIR is 0.5 dB; if RQI equals 2, the CIR is 1 dB; and so forth. Since there are multiple coding rates in the ACS, there is an adjustment threshold and an adjustment hysteresis between the neighboring coding rates. GBFD-115502AMR HR Interval Type 0~63 0~63 dB None 31 Cell The setting of this parameter must meet the following conditions: "ULTHH2" < "ULTHH3"; "ULTHH2" + "ULHYSTH2" < "ULTHH3" + "ULHYSTH3". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ULTHH3 AMR UL Coding Rate adj.th3[H] BSC6900 SET GCELLCCAMR(Optional) Based on the RQI in the call measurement report, the BTS and MS automatically adjust the current speech coding rate according to the related algorithm. The coding rate adjustment threshold is the threshold of RQI. The RQI indicates the carrier-to-interference ratio (CIR) of the call. If RQI equals 1, the CIR is 0.5 dB; if RQI equals 2, the CIR is 1 dB; and so forth. Since there are multiple coding rates in the ACS, there is an adjustment threshold and an adjustment hysteresis between the neighboring coding rates. GBFD-115502AMR HR Interval Type 0~63 0~63 dB None 63 Cell The setting of this parameter must meet the following conditions: "ULTHH2" < "ULTHH3"; "ULTHH2" + "ULHYSTH2" < "ULTHH3" + "ULHYSTH3". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ULTHWB1 AMR UL Coding Rate adj.th1[WB] BSC6900 SET GCELLCCAMR(Optional) Based on the RQI in the call measurement report, the BTS and MS automatically adjust the current speech coding rate according to the related algorithm. The coding rate adjustment threshold is the threshold of RQI. The RQI indicates the carrier-to-interference ratio (CIR) of the call. If RQI equals 1, the CIR is 0.5 dB; if RQI equals 2, the CIR is 1 dB; and so forth. Since there are multiple coding rates in the ACS, there is an adjustment threshold and an adjustment hysteresis between the neighboring coding rates. GBFD-115507WB AMR Interval Type 0~63 0~63 dB None 21 Cell The setting of this parameter must meet the following conditions: "ULTHWB1" < "ULTHWB2"; "ULTHWB1" + "ULHYSTWB1" < "ULTHWB2" + "ULHYSTWB2". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ULTHWB2 AMR UL Coding Rate adj.th2[WB] BSC6900 SET GCELLCCAMR(Optional) Based on the RQI in the call measurement report, the BTS and MS automatically adjust the current speech coding rate according to the related algorithm. The coding rate adjustment threshold is the threshold of RQI. The RQI indicates the carrier-to-interference ratio (CIR) of the call. If RQI equals 1, the CIR is 0.5 dB; if RQI equals 2, the CIR is 1 dB; and so forth. Since there are multiple coding rates in the ACS, there is an adjustment threshold and an adjustment hysteresis between the neighboring coding rates. GBFD-115507WB AMR Interval Type 0~63 0~63 dB None 25 Cell The setting of this parameter must meet the following conditions:"ULTHWB1" < "ULTHWB2"; "ULTHWB1" + "ULHYSTWB1" < "ULTHWB2" + "ULHYSTWB2". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ULTOOLHOALLOW UL to OL HO Allowed BSC6900 SET GCELLHOIUO(Optional) Whether a UL subcell to OL subcell handover is allowed. GBFD-113201Concentric Cell Enumeration Type NO(No), YES(Yes)NO, YES None None YES Cell This parameter is valid only when "IUOTP" in "ADD GCELL" is set to Concentric_cell. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
ulUlAckFreq ACK Frequency for GPRS Uplink TBF BSC6900 SET BSCPSSOFTPARA(Optional) Number of uplink GRPS TBF RLC blocks sent before an acknowledgement is required. GBFD-119105RLC Mode Interval Type 1~64 1~64 None None 32 BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
UMCROSSTALKOPTALLOWED Um Interface Crosstalk Optimization Allowed BSC6900 SET GCELLSOFT(Optional) Whether the crosstalk optimization function over the Um interface is allowed. If this parameter is set to YES when call drops occur on the Um interface, this function can avoid crosstalk due to very early assignment of the channel that is not released.If this parameter is set to YES and the ongoing service is speech service, the BSC also sends the Channel Release message to the MS and starts the timer T3109 when a call drop occurs upon the reception of the Conn Fail or Err Ind message reported by the MS. GBFD-111203O&M of BSC Enumeration Type NO(Not Allowed), YES(Allowed) NO, YES None None NO Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
UMPENALTYTIMER UmPenaltyTimer BSC6900 SET GCELLHOFITPEN(Optional) Timer of penalty on a neighboring cell when a handover fails due to faults of air interface connection. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 0~255 0~255 s None 10 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
UmVer Um Interface Tag BSC6900 SET BSCBASIC(Optional) Phase tag for GSM protocols that the Um interface supports MRFD-210301Configuration Management Enumeration Type GSM_PHASE_1, GSM_PHASE_2, GSM_PHASE_2Plus GSM_PHASE_1, GSM_PHASE_2, GSM_PHASE_2Plus None GSM_PHASE_2 GSM_PHASE_2 BSC6900Generally, the value of this parameter is equal to "A Interface Tag" and "Abis Interface Tag". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
UNBA Support Balance BSC6900 SET E1T1(Optional) Whether to support the balanced mode or the unbalanced mode None None Enumeration Type NO(NO), YES(YES) NO, YES None None None E1/T1 port None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
UNBLOCKRETRY Unblock Retry BSC6900 SET BSCNSPARA(Optional) retry times after the peer response timer expires during NSVC unblocking. GBFD-510002Gb Over FR Interval Type 1~6 1~6 None None 3 BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
UnderCurAlmThdA ANT_A ALD Under Current Occur Threshold BSC6900 SET BTSRXUBP(Optional) Abnormally alarm triggering threshold when the ANT_A tributary antenna current is too light. When the actual current is lower than the configured value, the ALD Current Abnormally Alarm is triggered with the corresponding alarm tributary No. of 1. MRFD-210304Faulty Management Interval Type 10~3500 10~3500 mA 40 40 BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
UnderCurAlmThdB ANT_B ALD Under Current Occur Threshold BSC6900 SET BTSRXUBP(Optional) Abnormally alarm triggering threshold when the ANT_B tributary antenna current is too light. When the actual current is lower than the configured value, the ALD Current Abnormally Alarm is triggered with the corresponding alarm tributary No. of 1. MRFD-210304Faulty Management Interval Type 10~3500 10~3500 mA 40 40 BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
UnderCurAlmThdRET RET ALD Under Current Occur Threshold BSC6900 SET BTSRXUBP(Optional) Abnormally alarm triggering threshold when the RET tributary antenna current is too light. When the actual current is lower than the configured value, the ALD Current Abnormally Alarm is triggered with the corresponding alarm tributary No. of 1. MRFD-210304Faulty Management Interval Type 10~3500 10~3500 mA 40 40 BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
UnderCurClrThdA ANT_A ALD Under Current Clear Threshold BSC6900 SET BTSRXUBP(Optional) Abnormally alarm clearance triggering threshold when the ANT_A tributary antenna current is too light. When the actual current is higher than the configured value, the ALD Current Abnormally Alarm disappears with the corresponding alarm tributary No. of 1. MRFD-210304Faulty Management Interval Type 10~3500 10~3500 mA 60 60 BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
UnderCurClrThdB ANT_B ALD Under Current Clear Threshold BSC6900 SET BTSRXUBP(Optional) Abnormally alarm clearance triggering threshold when the ANT_B tributary antenna current is too light. When the actual current is higher than the configured value, the ALD Current Abnormally Alarm disappears with the corresponding alarm tributary No. of 1. MRFD-210304Faulty Management Interval Type 10~3500 10~3500 mA 60 60 BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
UnderCurClrThdRET RET ALD Under Current Clear Threshold BSC6900 SET BTSRXUBP(Optional) Abnormally alarm clearance triggering threshold when the RET tributary antenna current is too light. When the actual current is higher than the configured value, the ALD Current Abnormally Alarm disappears with the corresponding alarm tributary No. of 1. MRFD-210304Faulty Management Interval Type 10~3500 10~3500 mA 60 60 BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
UPBTSID Up BTS Index BSC6900 ADD BTSAUTOPLAN(Mandatory) Index of upper-level BTS connected to the BTS GBFD-111202O&M of BTS Interval Type 0~2047 0~2047 None None None BTS None Read & Write Y BTS Less than 5 minutes None
UPBTSID Dest Father BTS Index BSC6900 ADD BTSCONNECT(Mandatory) Number of the upper-level BTS. The number is unique in a BSC. GBFD-111202O&M of BTS Interval Type 0~2047 0~2047 None None None BTS None Read & Write Y BTS Less than 5 minutes This parameter can be modified only when the BTS is deactivated.
UPBTSIDTYPE UPBTS Index type BSC6900 ADD BTSAUTOPLAN(Mandatory) Index type of upper-level BTS connected to the BTS GBFD-111202O&M of BTS Enumeration Type BYNAME(By Name), BYID(By Index) BYNAME, BYID None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
UPBTSIDTYPE Dest Father Index type BSC6900 ADD BTSCONNECT(Mandatory) Index type of the upper-level BTS GBFD-111202O&M of BTS Enumeration Type BYNAME(By Name), BYID(By Index) BYNAME, BYID None None None BTS None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
UPBTSNAME Up BTS Name BSC6900 ADD BTSAUTOPLAN(Mandatory) Name of the upper-level BTS connected to the BTS. The BTS name is unique within a same BSC. GBFD-111202O&M of BTS String Type None 1~64 characters None None None BTS None Read & Write Y BTS Less than 5 minutes None
UPBTSNAME Dest Father BTS Name BSC6900 ADD BTSCONNECT(Mandatory) Name of the upper-level BTS. The name is unique in a BSC. The invalid characters (\, /, :, *, ?, ", <, >, |, and #) cannot appear in the name. GBFD-111202O&M of BTS String Type None 1~64 characters None None None BTS None Read & Write Y BTS Less than 5 minutes This parameter can be modified only when the BTS is deactivated.
UPDATE Update BSC6900 ADD GSMSCB(Mandatory) Update code for a simple cell broadcast message.This parameter together with "Code" uniquely identifies a cell broadcast message. GBFD-113602Simplified Cell Broadcast Interval Type 0~15 0~15 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
UPDEFAULTCS Uplink Default CS Type BSC6900 SET GCELLPSCS(Optional) Default coding scheme of the uplink GPRS link. If the uplink adopts the dynamic adjustment coding scheme, this parameter can be used to set the coding scheme for transmission during initial access. If the uplink uses the fixed coding scheme, the TBF uses the fixed coding scheme. GBFD-119106Coding Scheme Enumeration Type CS1(CS1), CS2(CS2), CS3(CS3), CS4(CS4) CS1, CS2, CS3, CS4 None None CS1 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
UPDEFAULTMCS Uplink Default MCS Type BSC6900 SET GCELLEGPRSPARA(Optional) Default coding scheme of the uplink EDGE link. If the uplink adopts the dynamic adjustment coding scheme, this parameter can be used to set the coding scheme for transmission during initial access. If the uplink uses the fixed coding scheme, the TBF uses the fixed coding scheme. GBFD-114201EGPRS Enumeration Type MCS1(MCS1), MCS2(MCS2), MCS3(MCS3), MCS4(MCS4), MCS5(MCS5), MCS6(MCS6), MCS7(MCS7), MCS8(MCS8), MCS9(MCS9) MCS1, MCS2, MCS3, MCS4, MCS5, MCS6, MCS7, MCS8, MCS9 None None MCS2 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
UPDYNCHNTRANLEV Uplink Multiplex Threshold of Dynamic Channel Conversion BSC6900 SET GCELLPSCHM(Optional) Uplink multiplex threshold of dynamic channel conversion. When the subscriber number on the channel reaches the value (threshold/10), the dynamic channel conversion application is triggered. GBFD-113101PDCH Dynamic Adjustment Interval Type 10~70 10~70 None None 20 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
UPE2ADEFAULTMCS Uplink EGPRS2-A Default MCS Type BSC6900 SET GCELLEGPRSPARA(Optional) Default coding scheme used on the uplink EGPRS2-A link. If the uplink uses the dynamic coding scheme, this parameter specifies the coding scheme that is used for the transmission in initial access. If the uplink uses the fixed coding scheme, the TBF uses the fixed coding scheme. GBFD-510803Uplink EGPRS2-A Enumeration Type MCS1(MCS1), MCS2(MCS2), MCS3(MCS3), MCS4(MCS4), MCS5(MCS5), MCS6(MCS6), UAS7(UAS7), UAS8(UAS8), UAS9(UAS9), UAS10(UAS10), UAS11(UAS11) MCS1, MCS2, MCS3, MCS4, MCS5, MCS6, UAS7, UAS8, UAS9, UAS10, UAS11 None None MCS6 Cell This parameter is valid only when "EGPRS2A" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
UPE2AFIXMCS Uplink EGPRS2-A Fixed MCS Type BSC6900 SET GCELLEGPRSPARA(Optional) Fixed coding scheme that is used on the uplink EGPRS2-A link. If the uplink uses the fixed coding scheme, this parameter can be set to any one in MCS1-6 and UAS7-11. If the uplink uses the dynamic coding scheme, this parameter can be set to UNFIXED. GBFD-510803Uplink EGPRS2-A Enumeration Type MCS1(MCS1), MCS2(MCS2), MCS3(MCS3), MCS4(MCS4), MCS5(MCS5), MCS6(MCS6), UAS7(UAS7), UAS8(UAS8), UAS9(UAS9), UAS10(UAS10), UAS11(UAS11), UNFIXED(UNFIXED) MCS1, MCS2, MCS3, MCS4, MCS5, MCS6, UAS7, UAS8, UAS9, UAS10, UAS11, UNFIXED None None UNFIXED Cell This parameter is valid only when "EGPRS2A" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
UPEXTTBFINACTDELAY Inactive Period of Extended Uplink TBF BSC6900 SET GCELLPRIVATEOPTPARA(Optional) Inactive period of extended uplink TBF. After the network side receives the last uplink RLC data block (CountValue=0) of the MS supporting the extended uplink TBF, the uplink TBF is released immediately. Instead, the uplink TBF is set to the inactive state. In the inactive period, if the MS needs to transmit the uplink RLC data block, the MS can use the inactive uplink TBF without rebuilding a new uplink TBF. This inactive uplink TBF is switched to the active state automatically. At the end of the inactive period, if the MS does not transmit the uplink RLC data block, the network side sends the message Packet Uplink Ack/Nack to notify the MS of releasing the uplink TBF. When the uplink TBF is inactive, the downlink TBF can be established according to this uplink TBF. 0: disable the function of the extended uplink TBF (this function can be disabled on the BSC side). GBFD-119203Extended Uplink TBF Interval Type 0~5000 0~5000 ms None 2000 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
UPFIXCS Uplink Fixed CS Type BSC6900 SET GCELLPSCS(Optional) Adjustment mode of the uplink GPRS link coding scheme. If the fixed coding scheme is used, this parameter is a value ranging from CS1 to CS4. If the dynamic coding scheme is used, this parameter is set to UNFIXED. GBFD-119106Coding Scheme Enumeration Type CS1(CS1), CS2(CS2), CS3(CS3), CS4(CS4), UNFIXED(UNFIXED) CS1, CS2, CS3, CS4, UNFIXED None None UNFIXED Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
UPFIXMCS Uplink Fixed MCS Type BSC6900 SET GCELLEGPRSPARA(Optional) Coding scheme of the uplink EDGE link. If the uplink uses the fixed coding scheme, this parameter is set to a value ranging from MCS1 to MCS9. If the uplink uses the dynamic adjustment coding scheme, this parameter is set to UNFIXED. GBFD-114201EGPRS Enumeration Type MCS1(MCS1), MCS2(MCS2), MCS3(MCS3), MCS4(MCS4), MCS5(MCS5), MCS6(MCS6), MCS7(MCS7), MCS8(MCS8), MCS9(MCS9), UNFIXED(UNFIXED) MCS1, MCS2, MCS3, MCS4, MCS5, MCS6, MCS7, MCS8, MCS9, UNFIXED None None UNFIXED Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
UPINTERFQUALLIMIT Interf.of UL Qual. Threshold BSC6900 SET GCELLCHMGAD(Optional) One of the thresholds to determine whether the uplink interference exists. If the uplink level is not smaller than "Interf.of UL Level Threshold" and the uplink quality of the channel is not less than "Interf.of UL Qual. Threshold", the uplink interference exists. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 0~70 0~70 None None 40 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
UPINTERLEVLIMIT Interf.of UL Level Threshold BSC6900 SET GCELLCHMGAD(Optional) One of the thresholds to determine whether the uplink interference exists. If the uplink level is not smaller than "Interf.of UL Level Threshold" and the uplink quality of the channel is not less than "Interf.of UL Qual. Threshold", the uplink interference exists. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 0~63 0~63 dB None 30 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
UPLNKMAXLENGTH Uplink Max Length BSC6900 SET BTSFALLBACK(Optional) Maximum time in which a user uses the uplink of its VGCS call continuously when the BTS works in fallback mode GBFD-510309Group Call Reliability Enhancing Interval Type 10~255 10~255 s None 30 BTS This parameter is valid only when "ENABLE" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved This parameter is supported only by the following types of BTSs: BTS3012, BTS3006C, BTS3012AE, BTS3012 II, and BTS3002E.
UPPCEN UL PC Allowed BSC6900 SET GCELLBASICPARA(Optional) Whether to allow power control on the MS GBFD-110703GBFD-117601 Enhanced Power Control AlgorithmHUAWEI III Power Control Algorithm Enumeration Type NO(No), YES(Yes)NO, YES None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved In a GSM900 cell, the power control level of the MS ranges from 0 to 19. Generally, the maximum transmit power supported by an MS is level 5 (mapping to 33 dBm). The minimum transmit power supported by an MS is level 19 (mapping to 5 dBm). Other transmit power levels are reserved for high-power MSs.In a GSM1800 or GSM1900 cell, the power control level of the MS ranges from 0 to 31. Generally, the maximum transmit power supported by an MS is level 0 (mapping to 30 dBm). The minimum transmit power supported by an MS is level 15 (mapping to 2 dBm). Other transmit power levels are reserved for high-power MSs.
UPPERANI Upper Ani BSC6900 ADD ADJNODE(Mandatory) Whether to indicate it is the upper level adjacent node when "Is Root Node" is set to No. None None Interval Type 0~4599 0~4599 None None None Adjacent node When the value of "IsROOTNODE" in "ADD ADJNODE" is set to NO, this parameter is valid. Read & Write Not involved Not involved Not involved The parameter cannot be modified.
UPPERGRPID Upper Class Transport Resource Group No. BSC6900 ADD RSCGRP(Mandatory) Upper class transport resource group No. It is valid only when " Is First Class Transport Resource Group " is set to NO. None None Interval Type 0~2047 0~2047 None None None Transmission resource group When "ISFIRSTCLASSE" in "ADD RSCGRP" is set to NO, this parameter is valid. Read & Write Not involved Not involved Not involved The parameter cannot be modified.
UPPERLP The Upper logic port number BSC6900 ADD IPLOGICPORT(Optional) Upper number of the logical port None None Interval Type 512~1535 512~1535 None None None None None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
UPRXLEVLASTTIME Duration of uplink received level differ BSC6900 SET GCELLCHMGAD(Optional) If the difference between uplink receive levels of calls within the same timeslot is greater than "Offset of the difference between uplink received levels" for P seconds among N seconds, the call with weak uplink receive level within the timeslot will be handed over to another timeslot. This parameter corresponds to P in the P/N criterion. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 1~16 1~16 s None 4 Cell The following condition must be met: "UPRXLEVSTATICTIME" >= "UPRXLEVLASTTIME". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
UPRXLEVSMOOTHPARA Smooth factor of uplink received level BSC6900 SET GCELLCHMGAD(Optional) After the existing uplink receive level, uplink receive level after the previous optimization, and the value of this parameter are weight-averaged, the uplink receive level after the optimization at this time is obtained and used for determing the difference between the uplink receive levels. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 1~10 1~10, step:0.1 None None 6 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
UPRXLEVSTATICTIME Observ time of uplnk recv level diffr BSC6900 SET GCELLCHMGAD(Optional) If the difference between uplink receive levels of calls within the same timeslot is greater than "Offset of the difference between uplink received levels" for P seconds among N seconds, the call with weak uplink receive level within the timeslot will be handed over to another timeslot. This parameter corresponds to N in the P/N criterion. GBFD-110601GBFD-510501 HUAWEI I HandoverHUAWEI II Handover Interval Type 1~16 1~16 s None 5 Cell The following condition must be met: "UPRXLEVSTATICTIME" >= "UPRXLEVLASTTIME". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
UPSENDSMDIS Short Message Uplink Disabled BSC6900 SET GCELLCCAD(Optional) This parameter specifies whether the transmission of point-to-point short messages is disabled. If necessary, the transmission of the uplink short messages in a specific cell can be disabled so that sufficient radio channels can be seized by normal calls. GBFD-110203Point To Point Short Message Service (TS21, TS22) Enumeration Type NO(No), YES(Yes)NO, YES None None NO Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved Pay special attention to the setting of this parameter during an upgrade. If sending short messages is allowed, this parameter must be set to No.If this parameter is set to Yes, radio channels cannot be used to send short messages regardless of whether an MS is busy or not.
UPTBFRELDELAY Release Delay of Non-extended Uplink TBF BSC6900 SET GCELLPRIVATEOPTPARA(Optional) Delay of releasing the non-extended uplink TBF. After receiving the last uplink RLC data block (CountValue=0), the network side sends the message Packet Uplink Ack/Nack with FAI=1 to notify the MS of releasing the uplink TBF. After this parameter is set, the network side notifies the MS of releasing this TBF after specified delay. In this way, the downlink TBF can be established on the unreleased uplink TBF. This uplink TBF is automatically released when the downlink TBF is established or when the delay duration exceeds the time set by the uplink non-extended TBF. If this parameter is set to 0, the release delay of non-extended TBF is disabled. GBFD-119203Extended Uplink TBF Interval Type 0~300 0~300 ms None 120 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
UPTHDCSDEGRADE1 Uplink TBF Threshold from CS2 to CS1 BSC6900 SET GCELLPSCS(Optional) Retransmission threshold when the coding mode of the uplink TBF is changed from CS2 to CS1. When the retransmission rate of the uplink TBF is greater than or equal to this threshold, the coding mode of the uplink TBF is changed from CS2 to CS1. GBFD-119106Coding Scheme Interval Type 0~64 0~64 per cent None 10 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
UPTHDCSDEGRADE2 Uplink TBF Threshold from CS3 to CS2 BSC6900 SET GCELLPSCS(Optional) Retransmission threshold when the coding mode of the uplink TBF is changed from CS3 to CS2. When the retransmission rate of the uplink TBF is greater than or equal to this threshold, the coding mode of the uplink TBF is changed from CS3 to CS2. GBFD-118901CS-3/CS-4 Interval Type 0~64 0~64 per cent None 5 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
UPTHDCSDEGRADE3 Uplink TBF Threshold from CS4 to CS3 BSC6900 SET GCELLPSCS(Optional) Retransmission threshold when the coding mode of the uplink TBF is changed from CS4 to CS3. When the retransmission rate of the uplink TBF is greater than or equal to this threshold, the coding mode of the uplink TBF is changed from CS4 to CS3. GBFD-118901CS-3/CS-4 Interval Type 0~64 0~64 per cent None 5 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
UPTHDCSUPGRADE1 Uplink TBF Threshold from CS1 to CS2 BSC6900 SET GCELLPSCS(Optional) Retransmission threshold when the coding mode of the uplink TBF is changed from CS1 to CS2. When the retransmission rate of the uplink TBF is less than or equal to this threshold, the coding mode of the uplink TBF is changed from CS1 to CS2. GBFD-118901CS-3/CS-4 Interval Type 0~64 0~64 per cent None 5 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
UPTHDCSUPGRADE2 Uplink TBF Threshold from CS2 to CS3 BSC6900 SET GCELLPSCS(Optional) Retransmission threshold when the coding mode of the uplink TBF is changed from CS2 to CS3. When the retransmission rate of the uplink TBF is less than or equal to this threshold, the coding mode of the uplink TBF is changed from CS2 to CS3. GBFD-118901CS-3/CS-4 Interval Type 0~64 0~64 per cent None 2 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
UPTHDCSUPGRADE3 Uplink TBF Threshold from CS3 to CS4 BSC6900 SET GCELLPSCS(Optional) Retransmission threshold when the coding mode of the uplink TBF is changed from CS3 to CS4. When the retransmission rate of the uplink TBF is less than or equal to this threshold, the coding mode of the uplink TBF is changed from CS3 to CS4. GBFD-119106Coding Scheme Interval Type 0~64 0~64 per cent None 2 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
URGENTRESELALLOW Cell Urgent Reselection Allowed BSC6900 SET GCELLNC2PARA(Optional) Whether to allow the cell urgent reselection GBFD-116201Network-Controlled Cell Reselection (NC2) Enumeration Type FORBID(Forbid), PERMIT(Permit) FORBID, PERMIT None None PERMIT Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
USERIDTYPE User Query Type BSC6900 CHK INNSPCH(Mandatory)STR CALLRESLOP(Mandatory) Mode of querying the information on an MS GBFD-111203O&M of BSC Enumeration Type BYTMSI, BYIMSI, BYMSISDN, BYIMEI BYTMSI, BYIMSI, BYMSISDN, BYIMEI None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
USFGRAN4BLK Support USF Granularity 4 Switch BSC6900 SET BSCPSSOFTPARA(Optional) Whether to support USF granularity 4 switch. GBFD-114101GPRS Enumeration Type NOTSUPPORT(Not Support), SUPPORT(Support) NOTSUPPORT, SUPPORT None None SUPPORT BSC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
USR User Name of FTP Server BSC6900 DLD LICENSE(Mandatory)ULD LICENSE(Mandatory) User name of the FTP server GBFD-111203MRFD-210403 O&M of BSCLicense Management String Type None 1~32 characters None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
USR FTPServer User BSC6900 DLD BTSSW(Mandatory)DLD RETANTCFG(Mandatory)ULD BTSDEVFILE(Mandatory)DLD BTSPATCH(Mandatory)ULD BTSLOG(Mandatory) Username of the FTP server GBFD-111202O&M of BTS String Type None 1~32 characters None None None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
USTBGNTIME Energy Saving Start Time[HH:MM] BSC6900 SET BTSDOMUBP(Mandatory) Start time when the TRX energy saving function is enabled GBFD-111202O&M of BTS Compound Type HOUR, MINUTE HOUR 0~23MINUTE 0~59 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
USTENDTIME Energy Saving End Time[HH:MM] BSC6900 SET BTSDOMUBP(Mandatory) End time when the TRX energy saving function is enabled GBFD-111202O&M of BTS Compound Type HOUR, MINUTE HOUR 0~23MINUTE 0~59 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
UTEMTHD Upper Temperature Threshold BSC6900 SET BTSEXD(Optional) Upper temperature threshold for the environment alarm box to report an alarm indicating that the ambient temperature is too high. If the ambient temperature of the BTS is higher than this threshold, the environment alarm box reports the alarm.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. GBFD-111202O&M of BTS Interval Type -99~99 -99~99 degree Celsius None 50 BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The setting of this parameter must be greater than "LTEMTHD".
UTOOFAILMAXTIME MaxRetry Time after UtoO Fail BSC6900 SET GCELLHOIUO(Optional) When a UL subcell-OL subcel handover decision is performed to a call, the BSC determines whether the number of handover failures reaches the "MaxRetry Time after UtoO Fail". If the number reaches the threshold, the UL subcell to OL subcell handover is prohibited. Otherwise, the UL subcell to OL subcell handover is allowed. GBFD-113201Concentric Cell Interval Type 0~8 0~8 None None 3 Cell This parameter is valid only when "IUOTP" in "ADD GCELL" is set to Concentric_cell. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
UTOOHOPENTIME Penalty Time of UtoO HO BSC6900 SET GCELLHOIUO(Optional) After an MS performs a OL subcell to UL subcell handover successfully, the MS cannot be handed over to the OL subcell again within the value of the parameter. GBFD-113201Concentric Cell Interval Type 0~255 0~255 s None 10 Cell This parameter is valid only when "IUOTP" in "ADD GCELL" is set to ENIUO. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
UTOORECTH UtoO HO Received Level Threshold BSC6900 SET GCELLHOIUO(Optional) One of the parameters that determine the coverage of the OL subcell and of the UL subcell. "UtoO HO Received Level Threshold", "OtoU HO Received Level Threshold", "ReceiveQualThrshAMRFR", "TA Threshold", and "TA Hysteresis" determine the coverage of the OL subcell and UL subcell. GBFD-113201Concentric Cell Interval Type 0~63 0~63 dB None 35 Cell This parameter is valid only when "IUOTP" in "ADD GCELL" is set to ENIUO. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
UTOOTRAFHOALLOW UtoO Traffic HO Allowed BSC6900 SET GCELLHOIUO(Optional) When this parameter is set to YES, the existing call is performed in the OL subcell, and "OL to UL HO Allowed" is set to YES, an OL subcell to UL subcell handover is triggered if the traffic volume in the UL subcell is smaller than "En Iuo Out Cell Low Load Thred".If the existing call is performed in the UL subcell, a UL subcell to OL subcell handover is triggered, and "UL to OL HO Allowed" is set to YES, the timer is started and the calls in the UL subcell are hierarchically handed over to the OL subcell if the traffic volume in the UL subcell reaches "En Iuo Out Cell General OverLoad Thred". Otherwise, if the traffic volume in the UL subcell is smaller than "En Iuo Out Cell General OverLoad Thred", the timer stops, and hierarchical handovers are not performed.If this parameter is set to NO, the traffic volume in the UL subcell is not taken into account for triggering the UL subcell to OL subcell handover or the OL subcell to UL subcell handover in an enhanced concentric cell. GBFD-113201Concentric Cell Enumeration Type NO(No), YES(Yes)NO, YES None None YES Cell This parameter is valid only when "IUOTP" in "ADD GCELL" is set to ENIUO. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
UTRAFHOPERIOD Underlay HO Step Period BSC6900 SET GCELLHOIUO(Optional) Hierarchical handover period of the load handover from the UL subcell to the OL subcell. If the channel seizure ratio of the UL subcell is greater than the UL subcell general overload threshold, all the calls in the cell send handover requests at the same time and the load on the BSC increases in a short time. Thus, congestion may occur in the target cell and call drops may be caused. Through the hierarchical load handover algorithm, the calls in the cell are handed over to the OL subcell by level. This parameter indicates the duration lasts by each level of handover. GBFD-113201Concentric Cell Interval Type 1~255 1~255 s None 5 Cell This parameter is valid only when "IUOTP" in "ADD GCELL" is set to ENIUO. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
UTRAFHOSTEP Underlay HO Step Level BSC6900 SET GCELLHOIUO(Optional) Hierarchical level step of the load handover from the UL subcell to the OL subcell. GBFD-113201Concentric Cell Interval Type 1~63 1~63 dB None 5 Cell This parameter is valid only when "IUOTP" in "ADD GCELL" is set to ENIUO. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
UTRANCELLTYPE Utran cell type BSC6900 ADD GEXT3GCELL(Optional) Whether the 3G cell uses frequency division reuse or time division reuse. GBFD-114301GBFD-114302 GSM/WCDMA InteroperabilityGSM/TD-SCDMA Interoperability Enumeration Type FDD(FDD), TDD(TDD) FDD, TDD None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
VENDORCODE Vendor Code BSC6900 ADD BTSRETANT(Mandatory) Vendor code of the RET antenna GBFD-111202O&M of BTS String Type None 2 characters None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
VIPACCESSCPURATE VIP Access CPU Rate BSC6900 SET BSCFCPARA(Optional) This parameter specifies the usage threshold of the CPU for VIP user calls that can be admitted. When the usage of a CPU is greater than this threshold, the new service requests from VIP users are transferred to another CPU for processing. When the usage of all CPUs is greater than this threshold, all new service requests are rejected. GBFD-111705GSM Flow Control Interval Type 50~95 50~95 per cent None 95 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
VIPCELL VIP Cell BSC6900 ADD GCELL(Optional) Is VIP Cell GBFD-111705GSM Flow Control Enumeration Type NO(No), YES(Yes)NO, YES None NO NO Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
VIPPRIORITY VIP Priority BSC6900 SET BSCFCPARA(Optional) This parameter specifies the eMLPP priority value corresponding to the VIP call. When the eMLPP(Enhanced Multi-Level Precedence and Pre-emption service) priority value of a user is greater than or equal to the value of this parameter, the user is a VIP user. GBFD-111705GSM Flow Control Enumeration Type NONE(None), LEVEL4(User Level 4), LEVEL3(User Level 3), LEVEL2(User Level 2), LEVEL1(User Level 1), LEVEL0(User Level 0), LEVELB(User Level B), LEVELA(User Level A) NONE, LEVEL4, LEVEL3, LEVEL2, LEVEL1, LEVEL0, LEVELB, LEVELA None None LEVEL0 None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
VIPSHAREINCPURATE VIP Share in CPU Rate BSC6900 SET BSCFCPARA(Optional) This parameter specifies the usage threshold of the CPU for VIP user calls that are transferred from other CPUs. When the usage of a CPU is greater than this threshold, the VIP service requests transferred from other CPUs are directly discarded. GBFD-111705GSM Flow Control Interval Type 50~95 50~95 per cent None 90 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
VLANFlAG VLANID Flag BSC6900 ADD IPPATH(Optional) If the parameter is set to Disable, the added IP path is not configured with the VLAN ID. If the parameter is set to Enable, the added IP path is configured with the VLAN ID. None None Enumeration Type DISABLE(Disable), ENABLE(Enable) DISABLE, ENABLE None DISABLE DISABLE IP path None Read & Write Y IP path Less than 5 minutes None
VLANFLAG Vlan Flag BSC6900 SET BTSABISPRIMAP(Optional) Specified Vlan enabling flag None None Enumeration Type DISABLE, ENABLEDISABLE, ENABLE None None None BSC6900None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
VLANFLAG1 VLANID Flag of First Local IP address BSC6900 ADD SCTPLNK(Optional) VLANID flag of first local IP address. None None Enumeration Type DISABLE(DISABLE), ENABLE(ENABLE) DISABLE, ENABLE None DISABLE DISABLE BSC6900None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
VLANFlAG2 VLANID Flag of Second Local IP address BSC6900 ADD SCTPLNK(Optional) VLANID Flag of second Local IP address. None None Enumeration Type DISABLE(DISABLE), ENABLE(ENABLE) DISABLE, ENABLE None DISABLE DISABLE SCTP linkThis parameter determines whether the parameter "VLANID" in "ADD SCTPLNK" is valid. Read & Write Y SCTP link The services are interrupted until the SCTP link is working normally. The parameter determines whether the "VLANID" in the "ADD SCTPLNK" is functional.
5/5/2014
Confidential Information of Huawei.
No Spreading without Permission
Page21of42
226347869.xls.ms_office Security Level:
VLANID VLAN ID. BSC6900 ADD IPPATH(Mandatory)ADD VLANID(Mandatory) VLANID of the IP address of the specified next hop None None Interval Type 2~4094 2~4094 None None None BSC6900None Read & Write Y BSC6900 If the mode is not set back, will interrupt service until it is set back. Incorrect setting of this parameter can lead to access failure to the target IP address.
VLANID VLAN ID BSC6900 ADD ETHMA(Mandatory) VLAN of the MA in the MD GBFD-118630Ethernet OAM Interval Type 2~4094 2~4094 None None None Ethernet port None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
VLANID VLAN ID BSC6900 SET BTSVLAN(Optional) VLAN ID of the service type GBFD-118601Abis over IP Interval Type 2~4094 2~4094 None None None BTS This parameter is valid only when "VLANSWITCH" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
VLANID VLAN ID BSC6900 ADD BTSETHMA(Mandatory) VLAN to which the maintenance association belongs in the maintenance domain. GBFD-118630MRFD-210301 Ethernet OAMConfiguration Management Interval Type 2~4094 2~4094 None None None Ethernet port None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
VLANID1 VLAN ID of First Local IP address BSC6900 ADD SCTPLNK(Mandatory) VLAN ID of first Local IP address. None None Interval Type 2~4094 2~4094 None None None BSC6900None Read & Write Y BSC6900 If the mode is not set back, will interrupt service until it is set back. Incorrect setting of this parameter can lead to access failure to the target IP address.
VLANID2 VLAN ID of Second Local IP address BSC6900 ADD SCTPLNK(Mandatory) VLAN ID of second Local IP address. None None Interval Type 2~4094 2~4094 None None None BSC6900None Read & Write Y BSC6900 If the mode is not set back, will interrupt service until it is set back. Incorrect setting of this parameter can lead to access failure to the target IP address.
VLANPRI VLAN Priority BSC6900 SET DSCPMAP(Optional) VLAN priority None None Interval Type 0~7 0~7 None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The existing networking can be affected when the relation between the VLAN and the DSCP are reset.
VLANPRI VLAN Priority BSC6900 SET BTSVLAN(Optional) VLAN priority level of the service type. This parameter helps to determine the packet service priority level at the data link layer on the Ethernet. If this parameter is set to 0, the service type has the highest VLAN priority level. If this parameter is set to 7, the service type has the lowest VLAN priority level. GBFD-118601Abis over IP Interval Type 0~7 0~7 None None None BTS This parameter is valid only when "VLANSWITCH" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
VLANSWITCH VLAN Switch BSC6900 SET BTSVLAN(Optional) VLAN switch for the service type GBFD-118601Abis over IP Enumeration Type NO(N0), YES(Yes)NO, YES None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
VOICEDL UMTS AMR voice service downlink factor BSC6900 ADD TRMFACTOR(Optional) WCDMA AMR voice service downlink factor None None Interval Type 0~100 0~100 per cent 70 70 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node that is configured with the factor table. After the successful modification, the parameter takes effect in the following two cases:1. New access subscriber. 2. Bandwidth modification of the existing subscriber
VOICEPRIPATH AMR voice primary path BSC6900 ADD TRMMAP(Optional) AMR voice service bearer primary path None None Enumeration Type CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF None None When the interface type is Iub, transmission type is ATM or dual stack, the parameter is RT_VBR; transimssion type is IP or Hybird IP, the parameter is EF.When the interface type is Iur, transmission type is ATM, the parameter is RT_VBR; transimssion type is IP, the parameter is EF.When the interface type is Iu-CS, transmission type is ATM, the parameter is RT_VBR; transimssion type is IP, the parameter is EF. BSC6900When the value of "ITFT" in "ADD TRMMAP" is set to IUB or IUR or IUCS, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node configured with the TRMMAP. After the successful modification, it is valid in the case of the new access of a subscriber and the bandwidth modification of an existing subscriber.
VOICESECPATH AMR voice secondary path BSC6900 ADD TRMMAP(Optional) AMR voice service bearer secondary path None None Enumeration Type CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF, NULL CBR, RT_VBR, NRT_VBR, UBR, BE, AF11, AF12, AF13, AF21, AF22, AF23, AF31, AF32, AF33, AF41, AF42, AF43, EF, LQBE, LQAF11, LQAF12, LQAF13, LQAF21, LQAF22, LQAF23, LQAF31, LQAF32, LQAF33, LQAF41, LQAF42, LQAF43, LQEF, NULL None None When the interface type is Iub, transmission type is ATM or IP, the parameter is NULL; transimssion type is dual stack, the parameter is EF; transimssion type is Hybird IP, the parameter is LQEF.When the interface type is Iur, transmission type is ATM or IP, the parameter is NULL.When the interface type is Iu-CS, transmission type is ATM or IP, the parameter is NULL. BSC6900When the value of "ITFT" in "ADD TRMMAP" is set to IUB or IUR, this parameter is valid. Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node configured with the TRMMAP. After the successful modification, it is valid in the case of the new access of a subscriber and the bandwidth modification of an existing subscriber.
VOICEUL UMTS AMR voice service uplink factor BSC6900 ADD TRMFACTOR(Optional) WCDMA AMR voice service uplink factor None None Interval Type 0~100 0~100 per cent 70 70 BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved The modification of the parameter affects the adjacent node that is configured with the factor table. After the successful modification, the parameter takes effect in the following two cases:1. New access subscriber. 2. Bandwidth modification of the existing subscriber
VOICEVER Speech Version BSC6900 SET GCELLCCACCESS(Optional) Speech version supported by a cell MRFD-210301Configuration Management Bit Field Type FULL_RATE_VER1, FULL_RATE_VER2, FULL_RATE_VER3, HALF_RATE_VER1, HALF_RATE_VER2, HALF_RATE_VER3, FULL_RATE_VER5 Full_rate_Ver1, Full_rate_Ver2, Full_rate_Ver3, Half_rate_Ver1, Half_rate_Ver2, Half_rate_Ver3, Full_rate_Ver5 None None None Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
VOL24_MASK Enable Alarm Reporting for 24V Power BSC6900 ADD EMU(Optional) 24V voltage alarm switch MRFD-210304Faulty Management Enumeration Type CLOSE(Close), OPEN(Open) CLOSE, OPEN None OPEN None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
VOL24_THD_HIGH Upper Limit of Alarm for 24V Power BSC6900 ADD EMU(Optional) Upper limit for triggering a 24 V voltage sensor alarm MRFD-210304Faulty Management String Type None 1~9 characters V 28 None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
VOL24_THD_LOW Lower Limit of Alarm for 24V Power BSC6900 ADD EMU(Optional) Lower limit for triggering a 24 V voltage sensor alarm MRFD-210304Faulty Management String Type None 1~9 characters V 20 None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
VOL48_MASK Enable Alarm Reporting for 48V Power BSC6900 ADD EMU(Optional) 48V voltage alarm switch MRFD-210304Faulty Management Enumeration Type CLOSE(Close), OPEN(Open) CLOSE, OPEN None OPEN None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
VOL48_THD_HIGH Upper Limit of Alarm for 48V Power BSC6900 ADD EMU(Optional) Upper limit for triggering a 48V voltage sensor alarm MRFD-210304Faulty Management String Type None 1~9 characters V 57 None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
VOL48_THD_LOW Lower Limit of Alarm for 48V Power BSC6900 ADD EMU(Optional) Upper limit for triggering a 48V voltage sensor alarm MRFD-210304Faulty Management String Type None 1~9 characters V 42 None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
VSWRENABLED Standing Wave Alarm CFG Enabled BSC6900 SET BTSDFCUBP(Optional) Whether to enable the standing wave alarm parameters to be configured MRFD-210304Faulty Management Enumeration Type NO(NO), YES(YES) NO, YES None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
VSWRERRTHRES VSWR TRX Unadjusted Threshold BSC6900 SET GCELLOTHEXT(Optional) This parameter specifies a condition for generating a BTS alarm. This parameter together with "VSWR TRX error threshold" is used to detect whether the antenna system connected to the TRX is faulty. GBFD-111202O&M of BTS Interval Type 0~12 0~12 None None 2 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved If this parameter is set to a smaller value, the error is smaller.
VSWRFILETERCOUNTER Serious VSW Alarm Filter Times BSC6900 SET BTSDFCUBP(Optional)SET BTSDDPUBP(Optional) Filtering times of serious standing wave alarms MRFD-210304Faulty Management Interval Type 1~30 1~30 None None 3 BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
VSWRTHRES1 Standing Wave Radio Alarm Threshold BSC6900 SET BTSDFCUBP(Optional)SET BTSDDPUBP(Optional) Standing wave alarm threshold. When the VSWR is greater than the value of this parameter, the TRX reports a standing wave alarm. MRFD-210304Faulty Management Enumeration Type 14(1.4), 15(1.5), 16(1.6), 18(1.8), 20(2.0), 22(2.2), 24(2.4), 26(2.6), 28(2.8), 30(3.0), 33(3.3), 36(3.6), 88(8.8) 14, 15, 16, 18, 20, 22, 24, 26, 28, 30, 33, 36, 88 None None 20 BTS This parameter must be at least 0.2 smaller than "Serious VSW Alarm TH". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
VSWRTHRES2 Serious VSW Alarm TH BSC6900 SET BTSDFCUBP(Optional)SET BTSDDPUBP(Optional) Serious standing wave alarm threshold. When the VSWR is greater than the value of this parameter, the TRX reports a serious standing wave alarm. MRFD-210304Faulty Management Enumeration Type 18(1.8), 20(2.0), 22(2.2), 24(2.4), 26(2.6), 28(2.8), 30(3.0), 32(3.2), 35(3.5), 38(3.8), 41(4.1), 45(4.5), 88(8.8) 18, 20, 22, 24, 26, 28, 30, 32, 35, 38, 41, 45, 88 None None 30 BTS This parameter must be at least 0.2 greater than "Standing Wave Radio Alarm Threshold". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
VSWRUNJUSTTHRES VSWR TRX Error Threshold BSC6900 SET GCELLOTHEXT(Optional) This parameter specifies a condition for generating a BTS alarm. This parameter together with "VSWR TRX unadjusted threshold" are used to check whether the antenna system connecting to the TRX is faulty. If the value of this parameter is smaller, the error is smaller. GBFD-111202O&M of BTS Interval Type 0~12 0~12 None None 2 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
VVer V-Version No. BSC6900 SET BTSAUTODLDACTINFO(Mandatory) V-version number of the BTS software GBFD-111202O&M of BTS Interval Type 0~999 0~999 None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
WAITFORRELIND T3109 BSC6900 SET GCELLTMR(Optional) This timer is used to set the time of waiting for a ReleaseIndication message after a ChannelRelease message is sent. If the timer expires, the channel is deactivated. GBFD-111004Radio Dedicated Channel Management Interval Type 4000~33000 4000~33000 ms None 27000 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
WAITFORRELINDAMRFR Wait for REL Indication AMR FR BSC6900 SET GCELLTMR(Optional) When the BSC sends a ChannelRelease message and the current call uses the AMRFR encoding mode, the timer T3109 (AMRFR) is started. If the BSC receives the ReleaseIndication message before the T3109 (AMRFR) timer expires, the timer T3109 (AMRFR) is stopped. If the timer T3109 (AMRFR) expires, the BSC deactivates the channel. GBFD-115501AMR FR Interval Type 3000~34000 3000~34000 ms None 34000 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
WAITFORRELINDAMRHR T3109 for AMR HR BSC6900 SET GCELLTMR(Optional) When the BSC sends a ChannelRelease message and the current call uses the AMRHR encoding mode, the timer T3109 (AMRHR) is started. If the BSC receives the ReleaseIndication message before the T3109 (AMRHR) timer expires, the timer T3109 (AMRHR) is stopped. If the timer T3109 (AMRHR) expires, the BSC deactivates the channel. GBFD-115502AMR HR Interval Type 3000~34000 3000~34000 ms None 26000 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
WAITRESVCHANREFRESHTIMER Timer of Reserved TCH for EMC BSC6900 SET GCELLTMR(Optional) The TCHs reserved for the emergency call are assigned to the user during the service assignment. If the TCHs are not assigned to the emergency call within a period, the TCHs are released from the reservation queue. GBFD-110202Emergency Call Service (TS12) Interval Type 1~30 1~30 s None 15 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved If the timer is set to a greater value, the time of reserving channel resources for an emergency call is long. In this case, the channel usage for ordinary calls is affected. If the timer is set to a smaller value, reserved channel resources may not be assigned to an emergency call. In this case, the call fails.
WAITSDCCHIDLETIMER IBCA Wait SDCCH Idle Timer BSC6900 SET GCELLCHMGAD(Optional) When the dynamic PDCH needs to use MAIO of the SDCCH, the SDCCH is not allowed to be assigned to new calls within the value of the parameter. After the timer expires, check whether the SDCCH is idle. If the SDCCH is idle, MAIO of the SDCCH is allowed to be preempted. If the channel is not idle, the MAIO is not allowed to be preempted. GBFD-117002IBCA (Interference Based Channel Allocation) Interval Type 0~60 0~60 s None 4 Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
WARMSET Heating Equipment BSC6900 SET BTSOUTPUT(Optional) Whether to start the heating equipment of the BTS.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. GBFD-111202O&M of BTS Enumeration Type INACTIVE(Inactive), ACTIVE(Active) INACTIVE, ACTIVE None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
WATER_MASK Enable Water Alarm Reporting BSC6900 ADD EMU(Optional) Water sensor alarm switch MRFD-210304Faulty Management Enumeration Type CLOSE(Close), OPEN(Open) CLOSE, OPEN None OPEN None None None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
WBTONBHO WB-AMR switch to NB-AMR support BSC6900 SET BSCBASIC(Optional) When the TFO establishment fails, the broadband AMR can be switched to the FAMR. GBFD-115507WB AMR Enumeration Type OFF(Off), ON(On) OFF, ON None None OFF Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
WEEK Week Limit BSC6900 ADD OP(Optional)Whether to limit the operation weekday of the operator. If the weekday needs to be limited, see the description of "Week". GBFD-111203MRFD-210305 O&M of BSCSecurity Management Enumeration Type NOLIMIT(No Limit), LIMIT(Limit) NOLIMIT, LIMIT None NOLIMIT No Limit RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
WELONGI WE Longitude BSC6900 SET GCELLLCS(Optional) This parameter is used to select the location of a cell, east or west longitude. GBFD-115402BSS-Based LCS (Cell ID + TA) Enumeration Type East_Longitude(East Longitude), West_Longitude(West Longitude) East_Longitude, West_Longitude None None East_Longitude Cell None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
WETSET Humidification Equipment BSC6900 SET BTSOUTPUT(Optional) Whether to start the humidification equipment of the BTS.In multi-mode scenario, the value of this parameter in this mode must be the same as the value of the corresponding parameter in another mode. GBFD-111202O&M of BTS Enumeration Type INACTIVE(Inactive), ACTIVE(Active) INACTIVE, ACTIVE None None None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
WHETHERAFFECTSWAP Whether affect the port swapping BSC6900 STR IPCHK(Optional) This parameter is used to check the primary port. If it is set to YES, the system switches the primary port when detecting failure in the key test. GBFD-118609IP Fault Detection Based on BFD Enumeration Type NO(NO), YES(YES) NO, YES None None None None None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
WINADJSWITCH LAPD window adjust switch BSC6900 SET OTHSOFTPARA(Optional) Whether to start the dynamic adjustment of the LAPD window. If this parameter is set to ALLOW, the LAPD transmit and receive window is enlarged when the delay is increased, which improves the transmission efficiency of LAPD but consuming more buffer resources in the memory of the LAPD. GBFD-118601Abis over IP Enumeration Type DENY(Deny), ALLOW(Allow) DENY, ALLOW None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
WK Week BSC6900 ADD OP(Mandatory) You can select multiple weekdays. GBFD-111203MRFD-210305 O&M of BSCSecurity Management Enumeration Type SUN(Sunday), MON(Monday), TUE(Tuesday), WED(Wednesday), THU(Thursday), FRI(Friday), SAT(Saturday) SUN, MON, TUE, WED, THU, FRI, SAT None None None RNC None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
WKMODE Work mode BSC6900 ADD M3LKS(Optional) Work mode of the M3UA link set, including M3UA_ASP and M3UA_IPSP. For the description of the ASP and IPSP, see the RFC4666. None None Enumeration Type M3UA_ASP(M3UA_ASP), M3UA_IPSP(M3UA_IPSP) M3UA_ASP, M3UA_IPSP None M3UA_ASP M3UA_ASP BSC6900None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
WLAETIME End Time of WLA Detection<hour> BSC6900 SET GTRXRLALM(Optional) Time when the BTS stops checking for a radio link alarm. If this time is up, the BTS stops checking for or reporting a radio link alarm until the next alarm detection start time is up. GBFD-111202O&M of BTS Interval Type 0~24 0~24 h None 22 TRX This parameter is valid only when "WLNKALMFLAG" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
WLAFLAG Wireless Link Alarm Critical Permit BSC6900 SET GTRXRLALM(Optional) Whether to enable the BTS to report a major radio link alarm. If this parameter is set to YES, the BTS reports a major radio link alarm when a radio link warning is not cleared within "WLARP". If this parameter is set to NO, the BTS does not report any major radio link alarm. GBFD-111202O&M of BTS Enumeration Type NO(No), YES(Yes)NO, YES None None None TRX This parameter is valid only when "WLNKALMFLAG" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
WLARP WLA Prompting Recover Period BSC6900 SET GTRXRLALM(Optional) Period for clearing a radio link warning. If a radio link warning is cleared within this period, the BTS reports the recovery alarm for the warning. If a radio link warning is not cleared within this period, the BTS determines whether to report a major radio link alarm according to "WLAFLAG". GBFD-111202O&M of BTS Interval Type 1~255 1~255, step:5 min None None TRX This parameter is valid only when "WLNKALMFLAG" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
WLASTIME Begin Time of WLA Detection<hour> BSC6900 SET GTRXRLALM(Optional) Time when the BTS starts to check for a radio link alarm. If this time is up, the BTS starts to check for and report a radio link alarm. GBFD-111202O&M of BTS Interval Type 0~24 0~24 h None 8 TRX This parameter is valid only when "WLNKALMFLAG" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
WLNKALMFLAG Wireless Link Alarm Flag BSC6900 SET GTRXRLALM(Mandatory) Whether to enable the BSC to deliver radio link alarm parameters to the BTS. If this parameter is set to YES, the BSC delivers the radio link alarm parameters to the BTS. If this parameter is set to NO, the BSC does not deliver the radio link alarm parameters to the BTS. GBFD-111202O&M of BTS Enumeration Type NO(No), YES(Yes)NO, YES None None None TRX None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
WORKAREA Work Area Flag BSC6900 FMT DATA(Optional) flag of the work area to be formatted. None None Enumeration Type Active(Format active area), Standby(Format standby area) Active, Standby None Active Active BSC6900None Read & Write Not involved Not involved Not involved None
WORKINGSTANDARD Working Standard BSC6900 SET BTSRXUBP(Optional) Working mode of the RXU board GBFD-111202O&M of BTS Enumeration Type GSM_AND_UMTS(GSM AND UMTS), UMTS(UMTS), GSM(GSM) GSM_AND_UMTS, UMTS, GSM None GSM None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
WORKMODE Work Mode BSC6900 ADD SUBRACK(Mandatory) Work mode of subrack MRFD-210301Configuration Management Enumeration Type GO(GSM Only), UO(UMTS Only), GU(support GSM and UMTS) GO, UO, GU None None None None None Read & Write Not involved Not involved Not involved None
WORKMODE Work Mode BSC6900 SET E1T1(Optional) Working mode None None Enumeration Type E1_UNBA(E1 Unbalance), E1_BA(E1 Balance), T1(T1), E1(E1) E1_UNBA, E1_BA, T1, E1 None None E1_UNBA E1/T1 port None Read & Write Y BSC6900 Less than 5 minutes The conversion from E1 to T1 or from T1 to E1 takes effect after the board is reset.
WORKMODE Work Mode BSC6900 ADD BTS(Optional) Bts port working mode.This parameter must be consistent with that of the peer. None None Enumeration Type E1_UNBA(E1 Unbalance), E1_BA(E1 Balance), T1(T1), E1(E1) E1_UNBA, E1_BA, T1, E1 None E1 None BTS None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
WORKTYPE Work Type BSC6900 SET OPT(Optional) Optical interface type None None Enumeration Type UNI, NNI UNI, NNI None None None Board None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
WS Window Size BSC6900 ADD ATERSL(Optional)ADD ATERCONSL(Optional) Window size of the Ater signaling link. GBFD-111203O&M of BSC Interval Type 1~127 1~127 None None 16 ATERCONSL None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
WTBS Wait time before OML switch BSC6900 SET BTSOMLBACKUP(Optional) Time for which the BTS waits to swap the OML after the OML is interrupted. With this parameter, the BTS does not swap the OML when the OML is interrupted transiently. GBFD-113728OML Backup Interval Type 30~300 30~300 s None 90 BTS This parameter is valid only when "OMLBKUP" is set to YES. Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
WTBS Ring I Wait Time Before Switch BSC6900 SET BTSRINGATTR(Optional) Waiting time before establishing a link in the reverse direction after the transmission of a BTS is disrupted GBFD-117801Ring Topology Interval Type 60~300 60~300 s None None BTS This parameter must meet the following requirements: "FallBack Start Time" > "Ring I Wait Time Before Switch" + "Ring I Try Rotating Duration Time". Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
WTRT WTR Time[Sec] BSC6900 SET MSP(Optional) Wait to restore time. GBFD-111701Board Switchover Interval Type 30~60000 30~60000 s None 600 MSP protect group None Read & Write Not involved Not involved Not involved The parameter cannot be modified.
ZONET TimeZone BSC6900 SET TZ(Optional) Time zone MRFD-210301Configuration Management Enumeration Type GMT-1200(GMT-12:00), GMT-1100(GMT-11:00), GMT-1000(GMT-10:00), GMT-0930(GMT-09:30), GMT-0900(GMT-09:00), GMT-0800(GMT-08:00), GMT-0700(GMT-07:00), GMT-0600(GMT-06:00), GMT-0500(GMT-05:00), GMT-0430(GMT-04:30), GMT-0400(GMT-04:00), GMT-0330(GMT-03:30), GMT-0300(GMT-03:00), GMT-0200(GMT-02:00), GMT-0100(GMT-01:00), GMT(GMT), GMT+0100(GMT+01:00), GMT+0200(GMT+02:00), GMT+0300(GMT+03:00), GMT+0330(GMT+03:30), GMT+0400(GMT+04:00), GMT+0430(GMT+04:30), GMT+0500(GMT+05:00), GMT+0530(GMT+05:30), GMT+0545(GMT+05:45), GMT+0600(GMT+06:00), GMT+0630(GMT+06:30), GMT+0700(GMT+07:00), GMT+0800(GMT+08:00), GMT+0845(GMT+08:45), GMT+0900(GMT+09:00), GMT+0930(GMT+09:30), GMT+1000(GMT+10:00), GMT+1030(GMT+10:30), GMT+1100(GMT+11:00), GMT+1130(GMT+11:30), GMT+1200(GMT+12:00), GMT+1245(GMT+12:45), GMT+1300(GMT+13:00), GMT+1400(GMT+14:00) GMT-1200(GMT-12:00), GMT-1100(GMT-11:00), GMT-1000(GMT-10:00), GMT-0930(GMT-09:30), GMT-0900(GMT-09:00), GMT-0800(GMT-08:00), GMT-0700(GMT-07:00), GMT-0600(GMT-06:00), GMT-0500(GMT-05:00), GMT-0430(GMT-04:30), GMT-0400(GMT-04:00), GMT-0330(GMT-03:30), GMT-0300(GMT-03:00), GMT-0200(GMT-02:00), GMT-0100(GMT-01:00), GMT(GMT), GMT+0100(GMT+01:00), GMT+0200(GMT+02:00), GMT+0300(GMT+03:00), GMT+0330(GMT+03:30), GMT+0400(GMT+04:00), GMT+0430(GMT+04:30), GMT+0500(GMT+05:00), GMT+0530(GMT+05:30), GMT+0545(GMT+05:45), GMT+0600(GMT+06:00), GMT+0630(GMT+06:30), GMT+0700(GMT+07:00), GMT+0800(GMT+08:00), GMT+0845(GMT+08:45), GMT+0900(GMT+09:00), GMT+0930(GMT+09:30), GMT+1000(GMT+10:00), GMT+1030(GMT+10:30), GMT+1100(GMT+11:00), GMT+1130(GMT+11:30), GMT+1200(GMT+12:00), GMT+1245(GMT+12:45), GMT+1300(GMT+13:00), GMT+1400(GMT+14:00) None None None BSC6900None Read & Write N (No impact on the UE in idle mode) Not involved Not involved None
5/5/2014
Confidential Information of Huawei.
No Spreading without Permission
Page22of42
226347869.xls.ms_office Security Level:
Validation of Modification Impact on Radio Network Performance Introduced in Version Attribute
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The BTS should be reset to validate the parameter modification. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. The throughput is affected. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The transport path should be re-established after the parameter modification. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. The ACS may affect the MOS. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. The ACS may affect the MOS. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. The ACS may affect the MOS. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. The switching from an intra-cell handover procedure to an assignment procedure shortens the duration of the intra-cell handover. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The radio link should be reestablished after the parameter modification. None Versions earlier than BSC6900 V900R011 Equipment
The radio link should be reestablished after the parameter modification. None Versions earlier than BSC6900 V900R011 Equipment
The radio link should be reestablished after the parameter modification. None Versions earlier than BSC6900 V900R011 Equipment
The radio link should be reestablished after the parameter modification. None Versions earlier than BSC6900 V900R011 Equipment
The radio link should be reestablished after the parameter modification. None Versions earlier than BSC6900 V900R011 Equipment
The radio link should be reestablished after the parameter modification. If this parameter is set to OPEN, the acoustic echo can be cancelled to improve the speech quality. Versions earlier than BSC6900 V900R011 Equipment
The radio link should be re-established after the parameter modification. None BSC6900 V900R011 Equipment
The radio link should be reestablished after the parameter modification. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. If this parameter is set to higher value, channel resources may be wasted; if this parameter is set to lower value, the call drop rate may increase. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to higher value, channel resources may be wasted; if this parameter is set to lower value, the call drop rate may increase. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to higher value, channel resources may be wasted; if this parameter is set to lower value, the call drop rate may increase. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to higher value, channel resources may be wasted; if this parameter is set to lower value, the call drop rate may increase. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The radio link should be reestablished after the parameter modification. None Versions earlier than BSC6900 V900R011 Equipment
The radio link should be reestablished after the parameter modification. None Versions earlier than BSC6900 V900R011 Equipment
The radio link should be reestablished after the parameter modification. None Versions earlier than BSC6900 V900R011 Equipment
The radio link should be reestablished after the parameter modification. None Versions earlier than BSC6900 V900R011 Equipment
The radio link should be reestablished after the parameter modification. None Versions earlier than BSC6900 V900R011 Equipment
The radio link should be reestablished after the parameter modification. None Versions earlier than BSC6900 V900R011 Equipment
The radio link should be reestablished after the parameter modification. If this parameter is set to OPEN, the voltage level can be adjusted automatically to improve the speech quality. Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. If this parameter is set to a smaller value, the dynamic power adjustment range for the BTS is decreased. This may cause power waste and increase network interference when the downlink quality is good. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. When this parameter is set to YES and the value of the downlink threshold is not reasonable, the algorithm can be used to dynamically adjust the AMR downlink rate to increase the downlink speech MOS. BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a smaller value, downlink power control may not be performed when the voice quality is good, thus causing the power waste and increasing the interference. If this parameter is set to a greater value, downlink power control may be performed when the voice quality is bad, thus affecting the voice quality. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, uplink power control may not be performed when the voice quality is bad, thus affecting the voice quality. If this parameter is set to a smaller value, uplink power control may be performed when the voice quality is good, thus causing the power waste and increasing the interference. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, downlink power control may not be performed when the downlink level is high, thus causing the power waste and increasing the interference. If this parameter is set to a smaller value, downlink power control may be performed when the downlink power is low, in this way, call drops may occur. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, uplink power control may be performed when the downlink level is high, thus causing the power waste and increasing the interference. If this parameter is set to a smaller value, power control may not be performed when the downlink power is low, in this way, call drops may occur. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this switch is turned on, AMR FR calls can be switched into AMR HR calls to relieve the network congestion, but the voice quality is decreased; if this switch is turned off, AMR FR calls cannot be switched into AMR HR calls, that is, network congestion cannot be relieved through the handover from TCHF to TCHH. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, the handover margin is increased in a short period and many MSs are handed over from TCHF to TCHH, thus affecting the voice quality.If this parameter is set to a smaller value, the handover margin is enlarged slowly and it takes a long time to initiate a TCHF-TCHH handover. Thus, network congestion cannot be relieved in time. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, only MSs in the center of the cell can meet the handover condition. Thus, the network congestion cannot be relieved in time.If this parameter is set to a smaller value, MSs at the edge of the cell can also meet the handover condition, thus affecting the voice quality. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, the handover margin is increased in a short period and many MSs are handed over from TCHF to TCHH, thus affecting the voice quality.If this parameter is set to a smaller value, the handover margin is enlarged slowly and it takes a long time to initiate a TCHF-TCHH handover. Thus, network congestion cannot be relieved in time. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, MSs at the edge of the cell can also meet the handover condition, thus affecting the voice quality.If this parameter is set to a smaller value, only MSs in the center of the cell can meet the handover condition. Thus, the network congestion cannot be relieved in time. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, MSs with poor quality can also meet the handover condition, thus affecting the voice quality.If this parameter is set to a smaller value, little MSs can meet the handover condition. Thus, the network congestion cannot be relieved in time. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, the calls cannot be handed over to TCHH in a short period when the traffic volume is increased greatly. Thus, the network congestion cannot be relieved in time. If this parameter is set to a smaller value, calls are handed over to TCHH unnecessarily, thus causing MOS loss of the customer. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, only MSs in the center of the cell use the TCHH, thus leading to timeslot waste and the network congestion cannot be relieved in time. If this parameter is set to a smaller value, MSs at the edge of the cell and with poor quality also cannot be handed over to the TCHF, thus affecting the voice quality. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, MSs at the edge of the cell and with poor quality also cannot be handed over to the TCHF, thus affecting the voice quality. If this parameter is set to a smaller value, only MSs in the center of the cell use the TCHH, thus leading to timeslot waste and the network congestion cannot be relieved in time. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, handover cannot be triggered even when the quality is poor, thus affecting the voice quality; if this parameter is set to a smaller value, handover is triggered even when the quality is good, thus the network congestion cannot be relieved in time. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a smaller value, calls are handed over to TCHH unnecessarily, thus causing MOS loss of the customer; if this parameter is set to a greater value, TCHF-TCHH handover is performed only when the traffic volume is high, and thus network congestion may occur. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a smaller value, call drops may occur due to delayed power control; if this parameter is set to a greater value, power waste may occur and network interference may be increased. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a smaller value, fast power control cannot be realized. If this parameter is set to a greater value, the power control may be performed excessively, thus leading to call drops. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a smaller value, fast power control cannot be realized. If this parameter is set to a greater value, the power control may be performed excessively, thus leading to call drops. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a smaller value, fast power control cannot be realized. If this parameter is set to a greater value, the power control may be performed excessively, thus leading to call drops. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a smaller value, call drops may occur due to delayed power control; if this parameter is set to a greater value, power waste may occur and network interference may be increased. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, power control may not be performed in time. If this parameter is set to a smaller value, power control may be performed frequently, thus increasing the signaling load. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a smaller value, the algorithm cannot realize fast power control. If this parameter is set to a greater value, call drops may occur. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, cell congestion may not be relieved. If this parameter is set to a smaller value, TCHFs may be assigned unnecessarily, thus affecting the voice quality. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. When this parameter is set to YES and the value of the uplink threshold is not reasonable, the algorithm can be used to dynamically adjust the AMR uplink rate to increase the uplink speech MOS. BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a smaller value, downlink power control may not be performed when the voice quality is good, thus causing the power waste and increasing the interference. If this parameter is set to a greater value, downlink power control may be performed when the voice quality is bad, thus affecting the voice quality. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, uplink power control may not be performed when the voice quality is bad, thus affecting the voice quality. If this parameter is set to a smaller value, uplink power control may be performed when the voice quality is good, thus causing the power waste and increasing the interference. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, power control may not be performed when the uplink level is high, thus causing the power waste and increasing the interference. If this parameter is set to a smaller value, downlink power control may be performed when the uplink power is low, in this way, call drops may occur. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, uplink power control may be performed when the uplink level is high, thus causing the power waste and increasing the interference. If this parameter is set to a smaller value, power control may not be performed when the uplink power is low, in this way, call drops may occur. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The radio link should be reestablished after the parameter modification. None Versions earlier than BSC6900 V900R011 Equipment
The radio link should be reestablished after the parameter modification. If this parameter is set to OPEN, the noise can be compensated automatically to improve the speech quality. Versions earlier than BSC6900 V900R011 Equipment
The radio link should be reestablished after the parameter modification. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The radio link should be reestablished after the parameter modification. None Versions earlier than BSC6900 V900R011 Equipment
The radio link should be reestablished after the parameter modification. None Versions earlier than BSC6900 V900R011 Equipment
The radio link should be reestablished after the parameter modification. None Versions earlier than BSC6900 V900R011 Equipment
The radio link should be reestablished after the parameter modification. If this parameter is set to OPEN, the noise can be depressed automatically to improve the speech quality. Versions earlier than BSC6900 V900R011 Equipment
5/5/2014
Confidential Information of Huawei.
No Spreading without Permission
Page23of42
226347869.xls.ms_office Security Level:
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a higher value, channel resources may be wasted and congestion occurs; if this parameter is set to a lower value, the assignment success rate may decrease. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, the overlaid subcell range in the algorithm is smaller than the actual range, thus leading to the unbalance between the traffic volume on the overlaid subcell and that on the underlaid subcell. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, TCHFs are preferentially selected even when congestion occur on the Ater interface, thus decreasing the system capacity.If this parameter is set to a lower value, TCHHs are selected when no congestion occur on the Ater interface, thus decreasing the voice quality. Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The BSC should be reset to validate the parameter modification. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The transport path should be re-established after the parameter modification. None BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The transport path should be re-established after the parameter modification. None BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The transport path should be re-established after the parameter modification. None BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The transport path should be re-established after the parameter modification. None BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The BSC should be reset to validate the parameter modification. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The cell should be reset to validate the parameter modification. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, the handover cannot be performed in time, thus the voice quality is decreased and call drops may occur.If this parameter is set to a smaller value, unnecessary handovers may be performed. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, unnecessary handovers may be performed.If this parameter is set to a smaller value, handovers cannot be performed in time. Thus the voice quality is decreased and call drops may occur. Versions earlier than BSC6900 V900R011 Radio
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
Not involved None BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, the handover cannot be performed in time. Thus, the voice quality is decreased and call drops may occur.If this parameter is set to a smaller value, unnecessary handovers may be performed. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, unnecessary handovers may be performed.If this parameter is set to a smaller value, the handover cannot be performed in time. Thus, the voice quality is decreased and call drops may occur. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. The setting of this parameter may affect the MS paging response and performance of the system. A greater value may decrease the number of paging blocks, paging capacity, and paging success rate. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
5/5/2014
Confidential Information of Huawei.
No Spreading without Permission
Page24of42
226347869.xls.ms_office Security Level:
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The BTS should be reset to validate the parameter modification. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, the number of paging subchannels in a cell increases and the number of MSs on each paging subchannel decreases. This can prolong the average service life of MS batteries but increase the delay of paging messages and degrade the system performance. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved Not involved Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
Not involved Not involved Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The BTS should be reset to validate the parameter modification. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved Not involved BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The BTS should be reset to validate the parameter modification. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. If this parameter is set to BTS_Preprocessing, signaling on the Abis interface and BSC load are decreased, thus enhancing the response speed and the network performance. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
Not involved Not involved BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. If this parameter is set to a smaller value, the range of BTS dynamic power adjustment is decreased, and thus network interference is difficult to be reduced. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Equipment
Not involved Not involved BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. Call reestablishment can decrease the call drop rate but waste channel resources. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
Not involved None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. If this parameter is set to a smaller value, the status of RF resources is reported too frequently, thus burdening the BSC. If this parameter is set to a greater value, the status of RF resources cannot be updated in time; therefore, the BSC cannot handle the interference to the BTS, thus causing unreasonable channel allocation. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to smaller value, the signaling flow over the Abis interface increases, thus burdening the BSC. If this parameter is set to a greater value, the BSC cannot handle the exceptions on the BTS in time, thus causing network congestion. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a smaller value, dynamic adjustment may not be triggered when there are insufficient SDCCHs in the cell, this affects the access success rate. If this parameter is set to a greater value, traffic volume on the TCH is decreased. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. The feature of camping on the 3G cell after call release requires overlapped 2G/3G coverage area. Data services are preferably processed in the 3G network and speech services are preferably processed in the 2G network. When a handover from the 3G network to the 2G network is initiated, the call is handed over back to the 3G network after the call is complete, thus avoiding a location update. BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
5/5/2014
Confidential Information of Huawei.
No Spreading without Permission
Page25of42
226347869.xls.ms_office Security Level:
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. The setting of this parameter depends on the actual physical location of the chain neighboring cell. Otherwise, fast PBGT handover may fail. BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The BTS should be reset to validate the parameter modification. None Versions earlier than BSC6900 V900R011 Equipment
The BTS should be reset to validate the parameter modification. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The BTS should be reset to validate the parameter modification. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. This parameter can be used to limit the user access type to control the network load; however, some users may be adversely affected. Therefore, it is recommended that this parameter be disabled. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
Not involved Not involved Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The BTS should be reset to validate the parameter modification. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a smaller value, handovers may be performed frequently; if this parameter is set to a greater value, handovers may not be performed in time and call drops may occur. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a smaller value, handovers may be performed frequently; if this parameter is set to a greater value, handovers may not be performed in time and call drops may occur. Versions earlier than BSC6900 V900R011 Radio
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. The MS cannot respond to the paging during the location update, thus decreasing the call completion rate in the system.If this parameter is set to a smaller value, pingpong location update may occur, thus increasing the signaling load on the SDCCH.If this parameter is set to a greater value, the MS may not camp on an optimum cell for a long time after entering a new location area. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. If the value of this parameter is too high, the congestion control is delayed, which leads to deteriorated performance on the signaling link and certain messages may be lost.If the difference between the values of "CSTARTTHD" and "CENDTHD" is small, the signaling link is unstable and congestion control is performed frequently. In this case, the paging messages may be abandoned. Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Transport
The BTS should be reset to validate the parameter modification. None Versions earlier than BSC6900 V900R011 Radio
The BTS should be reset to validate the parameter modification. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
5/5/2014
Confidential Information of Huawei.
No Spreading without Permission
Page26of42
226347869.xls.ms_office Security Level:
Not involved None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this timer is set to a greater value, channel resources may be wasted, thus causing congestion. Versions earlier than BSC6900 V900R011 Radio
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The BTS should be reset to validate the parameter modification. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The cell should be activated after the parameter modification. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
Not involved Not involved Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Transport
Not involved None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. If this function is enabled, number of signaling channel handovers is increased and the access speed is decreased, but the congestion on the BCCH-compatible SDCCH can be relieved and the access success rate is enhanced. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a smaller value, call drops may occur due to delayed handover; if this parameter is set to a greater value, unnecessary handover may be performed, thus affecting the voice quality. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. The throughput of the GPRS service is affected. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a smaller value, downlink power control may not be performed when the voice quality is good, thus causing the power waste and increasing the interference. If this parameter is set to a greater value, downlink power control may be performed when the voice quality is bad, thus affecting the voice quality. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, uplink power control may not be performed when the voice quality is bad, thus affecting the voice quality. If this parameter is set to a smaller value, uplink power control may be performed when the voice quality is good, thus causing the power waste and increasing the interference. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, handover may not be performed when the downlink voice quality is bad, thus leading to call drops. If this parameter is set to a smaller value, unnecessary handovers may be performed, thus decreasing the user experience and network traffic load. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a smaller value, the handovers due to bad downlink quality may increase, thus decreasing the handover success rate. If this parameter is set to a greater value, handovers due to bad downlink quality are less possible to occur, thus increasing the call drop rate. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a smaller value, the handovers due to bad downlink quality may increase, thus decreasing the handover success rate. If this parameter is set to a greater value, handovers due to bad downlink quality are less possible to occur, thus increasing the call drop rate. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, decrease power control may not be performed when the downlink level is high, thus causing the power waste and increasing the interference. If this parameter is set to a smaller value, decrease power control may be performed when the downlink power is low, in this way, call drops may occur. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, increase power control may be performed when the downlink level is high, thus causing the power waste and increasing the interference. If this parameter is set to a smaller value, increase power control may not be performed when the downlink power is low, in this way, call drops may occur. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, decrease power control may not be performed when the downlink level is high, thus causing the power waste and increasing the interference. If this parameter is set to a smaller value, decrease power control may be performed when the downlink power is low, in this way, call drops may occur. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, increase power control may be performed when the downlink level is high, thus causing the power waste and increasing the interference. If this parameter is set to a smaller value, increase power control may not be performed when the downlink power is low, in this way, call drops may occur. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. The coding rate and MOS are affected. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. The coding rate and MOS are affected. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. The coding rate and MOS are affected. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. As the double antenna gain increases, the downlink power increases; as the double antenna gain decreases, the downlink power decreases. Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
5/5/2014
Confidential Information of Huawei.
No Spreading without Permission
Page27of42
226347869.xls.ms_office Security Level:
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The BTS should be reset to validate the parameter modification. None Versions earlier than BSC6900 V900R011 Radio
The BTS should be reset to validate the parameter modification. None Versions earlier than BSC6900 V900R011 Radio
The BTS should be reset to validate the parameter modification. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Transport
Not involved Not involved BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The BTS should be reset to validate the parameter modification. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, the corresponding neighboring 3G cell may be difficult to become the candidate neighboring cell of the serving cell. In this way, call drops may occur because the handovers may not be performed timely. If this parameter is set to a smaller value, a call may be handed over to a neighboring 3G cell with low signal strength, thus affecting voice quality. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater or a smaller value, the balance between the traffic volume on the overlaid subcell and that on the underlaid subcell may not be achieved. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, the handover cannot be performed in time. Thus, the voice quality is decreased and call drops may occur.If this parameter is set to a smaller value, unnecessary handovers may be performed. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, the handover cannot be performed in time. Thus, the voice quality is decreased and call drops may occur.If this parameter is set to a smaller value, unnecessary handovers may be performed. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, unnecessary handovers may be performed.If this parameter is set to a smaller value, the handover cannot be performed in time. Thus, the voice quality is decreased and call drops may occur. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, unnecessary handovers may be performed.If this parameter is set to a smaller value, the handover cannot be performed in time. Thus, the voice quality is decreased and call drops may occur. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The BTS should be reset to validate the parameter modification. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The BTS should be reset to validate the parameter modification. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, congestion may occur in the underlaid subcell; if this parameter is set to a smaller value, congestion may occur in the overlaid subcell. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. The number of block retransmissions is decreased and the throughput is increased. BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a smaller value, congestion may occur in the underlaid subcell in a short time; if this parameter is set to a greater value, congestion in the overlaid subcell is difficult to be relieved. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, congestion may occur in the underlaid subcell in a short time; if this parameter is set to a smaller value, congestion in the overlaid subcell is difficult to be relieved. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, traffic load on the underlaid subcell is increased, and thus congestion may occur in the underlaid subcell. If this parameter is set to a smaller value, traffic load on the overlaid subcell is increased, and thus congestion may occur in the overlaid subcell. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, the congestion relieving speed in the underlaid subcell is decreased. If this parameter is set to a smaller value, traffic load on the overlaid subcell is increased, and thus congestion may occur in the overlaid subcell. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to NO, the forced handover and call delay caused by timeslot arrangement can be avoided, but this may cause some TCHF-only calls to fail.If this parameter is set to Yes, calls may fail when the timeslot arrangement fails and when the MS does not select the TCHF in the concentric cell. Versions earlier than BSC6900 V900R011 Radio
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, congestion in the underlaid subcell may not be relieved in time. If this parameter is set to a smaller value, many calls may be handed over from the underlaid subcell to the overlaid subcell in a shot period, thus causing network congestion in the overlaid subcell and handover failure. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. If this timer is set to a greater value, channel resources may be wasted, thus causing congestion.If this timer is set to a smaller value, the success rate of immediate assignment may decrease. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, the effectiveness of power control is reduced, and thus the network interference can not be reduced effectively. If this parameter is set to a smaller value, call drops may occur due to excessive power control. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, the effectiveness of power control is reduced, and thus the network interference can not be reduced effectively. If this parameter is set to a smaller value, call drops may occur due to excessive power control. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The cell should be reset to validate the parameter modification. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, call drops may occur due to no suitable neighboring cell for handover. If this parameter is set to a smaller value, handover success rate may be decreased. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The board should be reset to validate the parameter modification. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The BTS should be reset to validate the parameter modification. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
5/5/2014
Confidential Information of Huawei.
No Spreading without Permission
Page28of42
226347869.xls.ms_office Security Level:
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. This parameter affects only the statistical result of the counter "FER I (I = 0-7) Quality Level N". BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. This parameter affects only the statistical result of the counter "FER I (I = 0-7) Quality Level N". BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. This parameter affects only the statistical result of the counter "FER I (I = 0-7) Quality Level N". BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. This parameter affects only the statistical result of the counter "FER I (I = 0-7) Quality Level N". BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. This parameter affects only the statistical result of the counter "FER I (I = 0-7) Quality Level N". BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. This parameter affects only the statistical result of the counter "FER I (I = 0-7) Quality Level N". BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. This parameter affects only the statistical result of the counter "FER I (I = 0-7) Quality Level N". BSC6900 V900R011 Radio
The cell should be reset to validate the parameter modification. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The BTS should be reset to validate the parameter modification. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The radio link should be reestablished after the parameter modification. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to YES, the speech quality is improved. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The BTS should be reset to validate the parameter modification. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. This technology prevents the loss of measurement reports caused by the BSIC that cannot be decoded, improves the system performance, and ensures the radio handover success rate of the BSC. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. The discontinuous transmission (DTX) function allows a transmitter to stop power transmission in the case of no voice transfer. This function has the following benefits: In the uplink: decreasing the power consumption of the MS and reducing system interference In the downlink: decreasing power consumption of the BTS, reducing system interference, and reducing intermodulation inside the BTSFrom the network perspective, the inter-frequency interference is reduced and the network quality is improved. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. The setting of this parameter must be consistent with the actual frequency reuse pattern of the TRX. Otherwise, the speech quality will be bad. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. The discontinuous transmission (DTX) function allows a transmitter to stop power transmission in the case of no voice transfer. This function has the following benefits: In the uplink: decreasing the power consumption of the MS and reducing system interference In the downlink: decreasing power consumption of the BTS, reducing system interference, and reducing intermodulation inside the BTSFrom the network perspective, the inter-frequency interference is reduced and the network quality is improved. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The BTS should be reset to validate the parameter modification. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The BTS should be reset to validate the parameter modification. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, the voice quality may be decreased.If this parameter is set to a smaller value, the congestion relieving capability may be decreased. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a smaller value, the duration of an AMR TCHF-TCHH handover is short after the handover is triggered. Thus, few MSs can be handed over from TCHF to TCHH, and the congestion relieving capability is decreased.If this parameter is set to a greater value, the duration of an AMR TCHF-TCHH handover is long after the handover is triggered. Thus, even the MSs on the edge of the cell are handed over from TCHF to TCHH, and the voice quality deteriorates. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, the handover cannot be performed in time and network congestion may occur.If this parameter is set to a smaller value, unnecessary handovers may be performed. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, network congestion may occur because the handover may not be performed timely.If this parameter is set to a smaller value, the voice quality may be decreased. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a smaller value, the handover zone is enlarged in a short time, and thus many MSs are handed over from TCHF to TCHH. If this parameter is set to a greater value, the handover zone is enlarged slowly and it takes a long time to initiate a TCHF-TCHH handover. Thus, and the congestion relieving capability is decreased. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, unnecessary handovers may be performed.If this parameter is set to a smaller value, network congestion may occur because the handover may not be performed timely. Versions earlier than BSC6900 V900R011 Radio
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
5/5/2014
Confidential Information of Huawei.
No Spreading without Permission
Page29of42
226347869.xls.ms_office Security Level:
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The BTS should be reset to validate the parameter modification. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, only an MS close to the overlaid subcell can be assigned TCHHs. Thus, timeslots are wasted. If this parameter is set to a smaller value, an MS of bad quality on the edge of the overlaid subcell cannot be handed over from TCHH to TCHF. Thus, the voice quality of the call is decreased. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, the TCHH-to-TCHF handover cannot be performed in time, thus the voice quality is decreased.If this parameter is set to a smaller value, unnecessary handovers may be performed. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, only MSs in the center area of the overlaid subcell can be assigned TCHHs. Thus, timeslots are wasted and the congestion relieving capability is decreased.If this parameter is set to a smaller value, MSs on the edge of the overlaid subcell also use the TCHH. Thus, the voice quality of the call is decreased. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, unnecessary handovers may be performed.If this parameter is set to a greater value, the handover cannot be performed in time, and thus the voice quality is decreased. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, the MS takes a longer time to meet the conditions for triggering the handover and the handover cannot be performed in time. Thus, call drops may occur or more handovers are triggered.If this parameter is set to a smaller value, the MS takes a shorter time to meet the conditions for triggering the handover, and thus network congestion may occur on the macro cell. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, congestion may occur in the macro cell.If this parameter is set to a smaller value, the handover cannot be performed in time. Thus, call drops may occur or more handovers are triggered. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. This parameter limits the number of candidate cells. If this parameter is set to a greater value, some desired cells may be excluded from the candidate cells and call drops may occur. If this parameter is set to a smaller value, an unwanted cell may become the candidate cell, thus leading to handover failures or call drops. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. This parameter limits the number of candidate cells. If this parameter is set to a greater value, some desired cells may be excluded from the candidate cells and call drops may occur. If this parameter is set to a smaller value, an unwanted cell may become the candidate cell, thus leading to handover failures or call drops. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to YES, the probability of MS handover to the cell in the direction opposite to the moving direction during fast handover is reduced. BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a great value, there are strict restrictions on the judgement of the MS moving direction. BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a great value, there are strict restrictions on the judgement of the MS moving direction. BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a smaller value, unnecessary handovers may be performed.If this parameter is set to a greater value, call drops may occur because the handover may not be performed timely. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, the handover cannot be performed in time. Thus, the voice quality is decreased and call drops may occur.If this parameter is set to a smaller value, unnecessary handovers may be performed. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, the handover cannot be performed in time. Thus, the voice quality is decreased and call drops may occur.If this parameter is set to a smaller value, unnecessary handovers may be performed. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, the handover cannot be performed in time and call drops may occur.If this parameter is set to a smaller value, unnecessary handovers may be performed. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, call drops may occur because the handover may not be performed timely.If this parameter is set to a smaller value, unnecessary handovers may be performed. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a smaller value, call drops may occur because the handover may not be performed timely.If this parameter is set to a greater value, unnecessary handovers may be performed. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, congestion may occur in the underlaid subcell.If this parameter is set to a smaller value, ping-pong handovers may occur. Versions earlier than BSC6900 V900R011 Radio
Not involved None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The cell should be reset to validate the parameter modification. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to YES, the probability that the BTS transmits at full power increases. This increases the interference but the handover success rate also increases. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The cell should be reset to validate the parameter modification. None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Equipment
The cell should be reset to validate the parameter modification. If this parameter is set to "NO_FH", the anti-interference capability of the TRX is decreased. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, it is difficult for the MS to be handed over to the original cell, thus leading to call drop when there is no suitable neighboring cell.If this parameter is set to a smaller value, the MS is likely to be handed over to the original cell again, thus leading to ping-pong handovers. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, the handover cannot be performed in time. Thus, the voice quality is decreased and call drops may occur.If this parameter is set to a smaller value, unnecessary handovers may be performed. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, unnecessary handovers may be performed.If this parameter is set to a smaller value, the handover cannot be performed in time. Thus, the voice quality is decreased and call drops may occur. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, unnecessary handovers may be performed.If this parameter is set to a smaller value, call drops may occur because the handover may not be performed timely. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Transport
The BTS should be reset to validate the parameter modification. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a smaller value, unnecessary handovers may be performed.If this parameter is set to a greater value, call drops may occur because the handover may not be performed timely. Versions earlier than BSC6900 V900R011 Radio
The cell should be activated after the parameter modification. None Versions earlier than BSC6900 V900R011 Radio
The cell should be activated after the parameter modification. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. The discontinuous transmission (DTX) function allows a transmitter to stop power transmission in the case of no voice transfer. This function has the following benefits: In the uplink: decreasing the power consumption of the MS and reducing system interference In the downlink: decreasing power consumption of the BTS, reducing system interference, and reducing intermodulation inside the BTSFrom the network perspective, the inter-frequency interference is reduced and the network quality is improved. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. The discontinuous transmission (DTX) function allows a transmitter to stop power transmission in the case of no voice transfer. This function has the following benefits: In the uplink: decreasing the power consumption of the MS and reducing system interference In the downlink: decreasing power consumption of the BTS, reducing system interference, and reducing intermodulation inside the BTSFrom the network perspective, the inter-frequency interference is reduced and the network quality is improved. Versions earlier than BSC6900 V900R011 Radio
The cell should be reset to validate the parameter modification. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. If this parameter is set to a smaller value, the network interference is increased; if this parameter is set to a greater value, congestion may occur in the cell. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a smaller value, the network interference is increased; if this parameter is set to a greater value, congestion may occur in the cell. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, the call duration is prolonged; if this parameter is set to a smaller value, the IBCA estimation accuracy is reduced. BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, the handover duration is prolonged and thus the handover cannot be performed in time; if this parameter is set to a smaller value, the IBCA estimation accuracy is reduced. BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a smaller value, the network interference is increased; if this parameter is set to a greater value, congestion may occur in the cell. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, the handover duration is prolonged and thus the handover cannot be performed in time; if this parameter is set to a smaller value, the IBCA estimation accuracy is reduced. BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a smaller value, the network interference is increased; if this parameter is set to a greater value, congestion may occur in the cell. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, the accuracy of interference assessment in the IBCA algorithm may be reduced; if this parameter is set to a smaller value, the CPU occupancy for IBCA algorithm is increased. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, the handover duration is prolonged and thus the handover cannot be performed in time; if this parameter is set to a smaller value, the IBCA estimation accuracy is reduced. BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, the accuracy of interference assessment in the IBCA algorithm may be reduced; if this parameter is set to a smaller value, the CPU occupancy for IBCA algorithm is increased. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to YES, cell congestion may occur when the interference is strong. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a smaller value, the network interference is increased; if this parameter is set to a greater value, congestion may occur in the cell. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
5/5/2014
Confidential Information of Huawei.
No Spreading without Permission
Page30of42
226347869.xls.ms_office Security Level:
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. If this parameter is set to a greater value and consequently there is a small number of requests for SDCCHs, the SDCCHs of a cell are in idle state and the TCH traffic volume during busy time is decreased.if this parameter is set to a smaller value and consequently there is a large number of requests for SDCCHs, the requests cannot be met and the access success rate is decreased. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this timer is set to a greater value, channel resources may be wasted, thus causing congestion. Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, the call-completion rate of MS increases but the BSC load may also increase.If this parameter is set to a smaller value, the increase of the call completion rate is not obvious. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, the call-completion rate of MS increases but the BSC load may also increase.If this parameter is set to a smaller value, the increase of the call completion rate is not obvious. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to YES, the call completion rate of the MS increases but the BSC load also increases. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a smaller value, the channel load may increase and the access success rate may decrease. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
Not involved None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, channel resources may be wasted, thus causing congestion. If this parameter is set to a smaller value, the handover success rate may decrease. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The BTS should be reset to validate the parameter modification. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, the traffic volume during busy time may be decreased.If this parameter is set to a smaller value, the voice quality may be decreased. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, the traffic volume during busy time may be decreased.If this parameter is set to a smaller value, the voice quality may be decreased. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If the value of this parameter is set too high, the power load of other timeslots or cells is burdened. Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. The setting of this parameter affects the MOS. When the C/I ratio is satisfactory, the coding scheme of higher rate is recommended; otherwise, the coding scheme of lower rate is recommended. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. The setting of this parameter affects the MOS. When the C/I ratio is satisfactory, the coding scheme of higher rate is recommended; otherwise, the coding scheme of lower rate is recommended. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. The setting of this parameter affects the MOS. When the C/I ratio is satisfactory, the coding scheme of higher rate is recommended; otherwise, the coding scheme of lower rate is recommended. BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, congestion may occur in the underlaid subcell in a short time; if this parameter is set to a smaller value, congestion in the overlaid subcell is difficult to be relieved. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The BTS should be reset to validate the parameter modification. None Versions earlier than BSC6900 V900R011 Radio
The BTS should be reset to validate the parameter modification. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The BTS should be reset to validate the parameter modification. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The BTS should be reset to validate the parameter modification. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, call drops may occur.If this parameter is set to a smaller value, handover may be performed frequently and the signaling load in the cell is increased. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, the handover cannot be performed in time. Thus, the voice quality is decreased and call drops may occur.If this parameter is set to a smaller value, unnecessary handovers may be performed. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, unnecessary handovers may be performed.If this parameter is set to a smaller value, the handover cannot be performed in time, thus the voice quality is decreased or call drops may occur. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, congestion may occur in the underlaid subcell;If this parameter is set to a smaller value, handover success rate may be decreased. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this timer is set to a greater value, channel resources may be wasted, thus causing congestion. If this timer is set to a smaller value, the handover success rate may decrease. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this timer is set to a greater value, channel resources may be wasted, thus causing congestion. If this timer is set to a smaller value, the handover success rate may decrease. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The BTS should be reset to validate the parameter modification. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The BTS should be reset to validate the parameter modification. None BSC6900 V900R011 Transport
The BTS should be reset to validate the parameter modification. None BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The BTS should be reset to validate the parameter modification. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The cell should be reset to validate the parameter modification. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
5/5/2014
Confidential Information of Huawei.
No Spreading without Permission
Page31of42
226347869.xls.ms_office Security Level:
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, congestion may occur in the macro subcell;If this parameter is set to a smaller value, unnecessary handovers may be performed, thus the voice quality is decreased and ping-pong handovers may be performed. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, unnecessary handovers may be performed, thus the voice quality is decreased and ping-pong handover may occur.If this parameter is set to a smaller value, congestion may occur in the macro subcell. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. If this parameter is set to a smaller value, handover to the corresponding cell may not be performed normally, thus the traffic congestion on the neighboring cells with high traffic cannot be relieved.If this parameter is set to a greater value, the corresponding cell may be over-loaded. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, it is difficult for the MS to be handed over to the serving cell, thus leading to call drop when there is no suitable neighboring cell.If this parameter is set to a smaller value, the MS is likely to be handed over to the serving cell again, thus leading to ping-pong handovers. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, it is difficult for the MS to be handed over to the serving cell, thus leading to call drop when there is no suitable neighboring cell.If this parameter is set to a smaller value, the MS is likely to be handed over to the serving cell again, thus leading to ping-pong handovers. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, congestion may occur in the neighboring cells in a short time; if this parameter is set to a smaller value, congestion in the serving cell is difficult to be relieved. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The BTS should be reset to validate the parameter modification. None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
Not involved Not involved BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The BSC should be reset to validate the parameter modification. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
Not involved Not involved BSC6900 V900R011 Equipment
The BTS should be reset to validate the parameter modification. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved Not involved Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The transport path should be re-established after the parameter modification. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a smaller value, call drops may occur due to delayed power control; if this parameter is set to a greater value, the power control may be performed excessively, thus leading to ping-pong power control. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
5/5/2014
Confidential Information of Huawei.
No Spreading without Permission
Page32of42
226347869.xls.ms_office Security Level:
The parameter modification has no impact on the equipment. If this parameter is set to a smaller value, call drops may occur or voice quality may be decreased due to delayed handover; if this parameter is set to a greater value, unnecessary handover may be performed. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. If this parameter is set to a smaller value, the algorithm cannot realize fast power control. If this parameter is set to a greater value, the power control may be performed excessively, thus leading to poor quality, low level, and ping-pong power control.. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a smaller value, the algorithm cannot realize fast power control. If this parameter is set to a greater value, the power control may be performed excessively, thus leading to poor quality, low level, and ping-pong power control.. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a smaller value, the algorithm cannot realize fast power control. If this parameter is set to a greater value, the power control may be performed excessively, thus leading to poor quality, low level, and ping-pong power control.. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a smaller value, the call drop rate may increase; if this parameter is set to a greater value, the speech quality may be affected. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. If this parameter is set to a smaller value, call drops may occur due to delayed power control; if this parameter is set to a greater value, the power control may be performed excessively, thus leading to ping-pong power control. Versions earlier than BSC6900 V900R011 Radio
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. In a multi-band network, this parameter can be set on the basis of the traffic volume on each frequency band. If this parameter is set to 0, the MS reports the measurement results of six neighboring cells known and permitted by the NCC at the bands with the best signal regardless of the band at which the neighboring cell is located. If this parameter is set to 1, the MS reports the measurement result of a neighboring cell known and permitted by the NCC at each band with the best signal (the band serving the current cell not included). The MS reports the measurement result of the neighboring cell at the band serving the current cell in the redundant position. If the redundant position is still available, the MS reports the measurement results of other neighboring cells regardless of the bands at which the neighboring cells are located.If this parameter is set to 2, the MS reports the measurement results of two neighboring cell known and permitted by the NCC at each band with the best signal (the band servi Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The transport path should be re-established after the parameter modification. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved Not involved Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved Not involved Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved Not involved Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The transport path should be re-established after the parameter modification. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. This parameter is used to limit the number of candidate cells for handovers.If this parameter is set to a greater value, some desired cells may be excluded from the candidate cells, thus leading to call drops.If this parameter is set to a smaller value, an unwanted cell may become a candidate cell, thus leading to handover failures. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a smaller value, the idle state of the current SDCCHs cannot be indicated correctly and consequently the rollback of SDCCHs immediately triggers adjustment and affects the access success rate.If this parameter is set to a larger value, the channel allocation algorithm becomes less sensitive and consequently the SDCCHs stay in idle state and cannot be rolled back for a long period of time, thus affecting the TCH traffic volume. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, some desired cells may be excluded from the candidate cells, thus leading to call drops.If this parameter is set to a smaller value, an unwanted cell may become a candidate cell, thus leading to handover failures. Versions earlier than BSC6900 V900R011 Radio
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The transport path should be re-established after the parameter modification. None Versions earlier than BSC6900 V900R011 Transport
The BTS should be reset to validate the parameter modification. If the value of this parameter is set too high, the RSL congestion is likely to occur. Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The transport path should be re-established after the parameter modification. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this timer is set to a greater value, the radio resources are occupied for a too long time, thus affecting the channel resource usage. If this timer is set to a smaller value, the call reestablishment success rate decreases. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. This parameter should be set as required: In the areas where the traffic volume is low, this parameter can be set to 4 or 7 to improve the success rate of MS access. In the areas where congestion occurs or in the micro cells where the traffic volume is high, it is recommended this parameter be set to 1. Versions earlier than BSC6900 V900R011 Radio
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. This parameter limits the number of candidate cells. If this parameter is set to a greater value, some desired cells may be excluded from the candidate cells and call drops may occur. If this parameter is set to a smaller value, an unwanted cell may become the candidate cell, thus leading to handover failures or call drops. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
5/5/2014
Confidential Information of Huawei.
No Spreading without Permission
Page33of42
226347869.xls.ms_office Security Level:
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. Only the BTS3X in G3BTS32.30000.04.1130 or later and the double-transceiver BTSs support the LAPDm N200 parameter.If this parameter is set to Yes, the BSC sends the LAPDm N200 parameter. If this parameter is set to OFF, the BSC does not send the LAPDm N200 parameter.If a BTS does not support this parameter, the parameter should be set to No. Otherwise, the BTS cannot be initialized. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. When this parameter is set to ENABLE, the MOS can be increased in a call between MSs. Versions earlier than BSC6900 V900R011 Radio
The BSC should be reset to validate the parameter modification. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. The most significant three bits of BSIC for all cells map with the NCC. NCC Permitted should be set properly to avoid too many call drops. The MS does not report the information on the neighboring cells in the network whose corresponding NCC bit is set to 0. Thus, this parameter should be set properly. Otherwise, an MS during an ongoing call cannot perform normal handover and a cross-coverage call drop occurs. For details, see GSM Rec. 05. 08.During an ongoing call, the MS reports to the BTS the signal information on neighboring cells. A report covers a maximum of six cells. Thus, the MS should report those possible target cells, rather than selecting cells only based on the signal level. Generally, the MS does not report the information on the cells belonging to other GSM PLMNs.This function enables the MS to measure only those specified cells. This parameter specifies the codes of the NCCs to be measured by the MS.On the SCH, the system constantly transmits the BSIC, the first three bits of which indicat Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. If this parameter is set to a smaller value, handovers are performed frequently; if this parameter is set to a greater value, handovers cannot be performed timely, thus leading to call drops. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. If this parameter is set to YES, FR calls can be switched into HR calls to relieve the network congestion, but the voice quality is decreased; if this parameter is set to NO, FR calls cannot be switched into HR calls, that is, network congestion cannot be relieved through the handover from TCHF to TCHH. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, the handover margin is increased in a short period and many MSs are handed over from TCHF to TCHH, thus affecting the voice quality.If this parameter is set to a smaller value, the handover margin is enlarged slowly and it takes a long time to initiate a TCHF-TCHH handover. Thus, the network congestion cannot be relieved in time. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, only MSs in the center of the cell can meet the handover condition. Thus, the network congestion cannot be relieved in time.If this parameter is set to a smaller value, MSs at the edge of the cell can also meet the handover condition, thus affecting the voice quality. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, the handover margin is increased in a short period and many MSs are handed over from TCHF to TCHH, thus affecting the voice quality.If this parameter is set to a smaller value, the handover margin is enlarged slowly and it takes a long time to initiate a TCHF-TCHH handover. Thus, network congestion cannot be relieved in time. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, MSs at the edge of the cell can also meet the handover condition, thus affecting the voice quality.If this parameter is set to a smaller value, only MSs in the center of the cell can meet the handover condition. Thus, the network congestion cannot be relieved in time. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, MSs with poor quality can also meet the handover condition, thus affecting the voice quality.If this parameter is set to a smaller value, little MSs can meet the handover condition. Thus, the network congestion cannot be relieved in time. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, the calls cannot be handed over to TCHH in a short period when the traffic volume is increased greatly. Thus, the network congestion cannot be relieved in time. If this parameter is set to a smaller value, calls are handed over to TCHH unnecessarily, thus causing MOS loss of the customer. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, only MSs in the center of the cell use the TCHH, thus leading to timeslot waste and the network congestion cannot be relieved in time. If this parameter is set to a smaller value, MSs at the edge of the cell and with poor quality also cannot be handed over to the TCHF, thus affecting the voice quality. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, MSs at the edge of the cell and with poor quality also cannot be handed over to the TCHF, thus affecting the voice quality. If this parameter is set to a smaller value, only MSs in the center of the cell use the TCHH, thus leading to timeslot waste and the network congestion cannot be relieved in time. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, handover cannot be triggered even when the quality is poor, thus affecting the voice quality; if this parameter is set to a smaller value, handover is triggered even when the quality is good, thus the network congestion cannot be relieved in time. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a smaller value, calls are handed over to TCHH unnecessarily, thus causing MOS loss of the customer; if this parameter is set to a greater value, TCHF-TCHH handover is performed only when the traffic volume is high, thus network congestion may occur. Versions earlier than BSC6900 V900R011 Radio
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. The handover decision is allowed only when the uplink receive quality is greater than or equal to the value of this parameter. Therefore, if this parameter is set to a greater value, the handovers due to no-downlink measurement report cannot be triggered. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
Not involved None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. This parameter should be set to a small value because the signaling channel seizure duration is shorter than the traffic channel seizure duration for the MS. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The cell should be activated after the parameter modification. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, congestion may occur in the underlaid subcell; if this parameter is set to a smaller value, assignment success rate may be decreased. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, assignment success rate may be decreased; if this parameter is set to a smaller value, congestion may occur in the underlaid subcell. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The transport path should be re-established after the parameter modification. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, congestion may occur in the overlaid subcell; if this parameter is set to a smaller value, congestion may occur in the underlaid subcell. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If the value of this parameter is set too small, frequent handovers are likely to occur. Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, congestion may occur in the overlaid subcell; if this parameter is set to a smaller value, congestion may occur in the underlaid subcell. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, congestion may occur in the overlaid subcell in a short time; if this parameter is set to a smaller value, congestion in the underlaid subcell is difficult to be relieved. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, congestion in the underlaid subcell is difficult to be relieved; if this parameter is set to a smaller value, congestion may occur in the overlaid subcell in a short time. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, congestion may occur in the overlaid subcell in a short time; if this parameter is set to a smaller value, congestion in the underlaid subcell is difficult to be relieved. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, congestion may occur in the underlaid subcell; if this parameter is set to a smaller value, congestion may occur in the overlaid subcell. Versions earlier than BSC6900 V900R011 Radio
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The BTS should be reset to validate the parameter modification. None Versions earlier than BSC6900 V900R011 Transport
The BTS should be reset to validate the parameter modification. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
5/5/2014
Confidential Information of Huawei.
No Spreading without Permission
Page34of42
226347869.xls.ms_office Security Level:
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, congestion may occur in the underlaid subcell; if this parameter is set to a smaller value, congestion may occur in the overlaid subcell. BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
Not involved None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. If this parameter is set to a smaller value, the BTS frequently reports overload indication messages to the BSC. As a result, the BSC frequently reports overload indication messages to the MSC and thus the MSC may initiate flow control. If this parameter is set to a greater value, the BTS sends overload indication messages to the BSC only when a large number of MSs access the network and when the system resources are insufficient. Therefore, the access requests on the RACH and all the messages on the PCH are discarded. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. Properly setting this parameter can increase the paging success rate. If this parameter is set to a greater value, paging overload may occur and the paging success rate may decrease. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, the handover cannot be performed in time and call drops may occur.If this parameter is set to a smaller value, unnecessary handovers may be performed. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, unnecessary handovers may be performed; if this parameter is set to a smaller value, handovers may not be performed in time and call drops may occur. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
Not involved None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The BTS should be reset to validate the parameter modification. None Versions earlier than BSC6900 V900R011 Radio
The BTS should be reset to validate the parameter modification. None Versions earlier than BSC6900 V900R011 Radio
The BTS should be reset to validate the parameter modification. None Versions earlier than BSC6900 V900R011 Radio
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The transport path should be re-established after the parameter modification. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, the target cell for the previous handover will not be selected for the next handover, but the probability of call drop increases. If this parameter is set to a smaller value, the probability of handover failure increases. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The transport path should be re-established after the parameter modification. None Versions earlier than BSC6900 V900R011 Transport
The transport path should be re-established after the parameter modification. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. The MS calculates C1 and C2 of the serving cell at a minimum interval of 5s. When necessary, the MS re-calculates C1 and C2 of all non-serving cells (neighboring cells). The MS constantly checks whether a cell reselection is required by checking following conditions:Whether the path loss (C1) of the current serving cell drops below 0 within 5s. If yes, the path loss is too large. C2 of an appropriate non-serving cell exceeds that of the serving cell in 5s and the following conditions are met:The C2 of a new cell in another LAC minus CRH (broadcast in the system information 3 and 4 of the serving cell) exceeds C2 of the serving cell in 5s.A cell reselection is performed in the last 15s, and the C2 of the new cell minus 5 dB constantly exceeds the C2 of the serving cell in 5s.A better cell exists if the above conditions are met. If a better cell exists, the MS reselects a cell, and does not select the previous cell within 5s. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The transport path should be re-established after the parameter modification. None Versions earlier than BSC6900 V900R011 Radio
The transport path should be re-established after the parameter modification. None Versions earlier than BSC6900 V900R011 Radio
The transport path should be re-established after the parameter modification. None Versions earlier than BSC6900 V900R011 Radio
The BTS should be reset to validate the parameter modification. None Versions earlier than BSC6900 V900R011 Radio
The BTS should be reset to validate the parameter modification. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Equipment
The BTS should be reset to validate the parameter modification. None Versions earlier than BSC6900 V900R011 Radio
The transport path should be re-established after the parameter modification. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
Not involved Not involved Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
5/5/2014
Confidential Information of Huawei.
No Spreading without Permission
Page35of42
226347869.xls.ms_office Security Level:
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The transport path should be re-established after the parameter modification. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, the call drop rate decreases but the traffic volume and paging success rate are affected. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, the call drop rate decreases but the traffic volume and paging success rate are affected. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. The setting of this parameter affects the GSM Phase II MS. Versions earlier than BSC6900 V900R011 Radio
Not involved None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. If the value of this parameter is set inappropriately high or small, the BTS cabinet top output power is inconsistent with the TRX output power. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, unnecessary handovers between micro cells are performed, thus affecting the voice quality. If this parameter is set to a smaller value, congestion may occur in macro cells. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, congestion may occur in macro cells. If this parameter is set to a smaller value, unnecessary handovers between micro cells are performed, thus affecting the voice quality. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, downlink power insufficiency may not be solved in time, thus leading to call drops.If this parameter is set to a smaller value, unnecessary handovers may be performed, thus the voice quality is decreased. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, unnecessary handovers may be performed, thus the voice quality is decreased.If this parameter is set to a smaller value, downlink power insufficiency may not be solved in time, thus leading to call drops. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. If this parameter is set to a smaller value, the algorithm cannot realize fast power control. If this parameter is set to a greater value, the power control may be performed excessively, thus leading to poor quality, low level, and ping-pong power control. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, the call drop rate decreases but the traffic volume and paging success rate are affected. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, the call drop rate decreases but the traffic volume and paging success rate are affected. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a smaller value, the random access success rate may decrease. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a smaller value, the BTS frequently sends the overload messages to the BSC. Thus, the system resource usage decreases and MSs are difficult to access the network.If this parameter is set to a greater value, the BTS sends an overload message to the BSC at a long interval. Thus, system faults may occur. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a smaller value, the allowable error rate for the random access signal is high and an MS can easily access the network; however, the error report rate is high. If this parameter is set to a greater value, the error report rate of the MS is low but the MS cannot easily access the network. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. When this parameter is set to on, the MOS of a MS-initiated and MS-terminated call is improved. BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. If this parameter is set to YES, the BSC initiates a reassignment when receiving an assignment failure message over the Um interface. This helps increase the call completion rate and improve the QoS of the network. The successful reassignment, however, results in an increase in the access delay of MSs and the load of the BSC. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
5/5/2014
Confidential Information of Huawei.
No Spreading without Permission
Page36of42
226347869.xls.ms_office Security Level:
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, too many channels may be reserved for the users with high priority, and the users with low priority may be failed to access channels. If this parameter is set to a smaller value, channels reserved for the users with high priority may be insufficient. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a smaller value, the radio resource status is reported too frequently, thus increasing the load of the BSC.If this parameter is set to a greater value, the radio resource status is not immediately reported and thus the BSC cannot handle the interference to the BTS in time. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The transport path should be re-established after the parameter modification. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. If this parameter is set to a smaller value, the radio link is vulnerable to failure, thus call drops are likely to occur.If this parameter is set to a greater value, the MS may not release the connection for a long time, thus decreasing the resource usage. The parameter is valid in the downlink. Versions earlier than BSC6900 V900R011 Radio
The BSC should be reset to validate the parameter modification. None BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, call drops may occur due to no suitable neighboring cell for handover. If this parameter is set to a smaller value, handover success rate may be decreased. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, some desired cells may be excluded from the candidate cells, thus leading to call drops.If this parameter is set to a smaller value, an unwanted cell may become a candidate cell, thus leading to handover failures. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The BTS should be reset to validate the parameter modification. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. When this parameter is set to on, the MOS of a MS-initiated and MS-terminated call is improved. BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, the call drop rate decreases but the traffic volume and paging success rate are affected. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
Not involved None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. If this function is enabled after encryption is enabled, the network security can be improved. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. The TRX is shut down automatically, and the capacity of the cell is decreased. Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, the handover cannot be performed in time and call drops may occur. If this parameter is set to a smaller value, unexpected handovers may be performed due to incorrect MR when the call is initially set up, thus affecting handover success rate. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, the handover to micro cells becomes difficult, and congestion may occur in macro cells. If this parameter is set to a smaller value, unnecessary handovers are performed, thus affecting the voice quality. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, the handover to micro cells becomes difficult, and congestion may occur in macro cells. If this parameter is set to a smaller value, unnecessary handovers are performed, thus affecting the voice quality. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The BTS should be reset to validate the parameter modification. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The BSC should be reset to validate the parameter modification. None Versions earlier than BSC6900 V900R011 Equipment
The BTS should be reset to validate the parameter modification. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
5/5/2014
Confidential Information of Huawei.
No Spreading without Permission
Page37of42
226347869.xls.ms_office Security Level:
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
Not involved None BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
Not involved Not involved BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Transport
The transport path should be re-established after the parameter modification. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. This parameter can be used to control network load based on the MS access classes, thus preventing some MSs from accessing the network. It is recommended that this parameter be not used. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, the handover to micro cells becomes difficult, and congestion may occur in macro cells.If this parameter is set to a smaller value, more handovers may be performed, thus the voice quality is decreased. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, the handover to micro cells becomes difficult, and congestion may occur in macro cells.If this parameter is set to a smaller value, more handovers may be performed, thus the voice quality is decreased. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The BTS should be reset to validate the parameter modification. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Transport
The parameter modification does not impact the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Equipment
Not involved None BSC6900 V900R011 Transport
The transport path should be re-established after the parameter modification. None Versions earlier than BSC6900 V900R011 Radio
The transport path should be re-established after the parameter modification. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, it is difficult for the MS to be handed over to the original cell, thus leading to call drop when there is no suitable neighboring cell. If this parameter is set to a smaller value, the MS is likely to be handed over to the original cell again, thus leading to ping-pong handovers. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, it is difficult for the MS to be handed over to the original cell, thus leading to call drop when there is no suitable neighboring cell. If this parameter is set to a smaller value, the MS is likely to be handed over to the original cell again, thus leading to ping-pong handovers. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
5/5/2014
Confidential Information of Huawei.
No Spreading without Permission
Page38of42
226347869.xls.ms_office Security Level:
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The transport path should be re-established after the parameter modification. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The transport path should be re-established after the parameter modification. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The transport path should be re-established after the parameter modification. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. Not involved Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If timer T200 is set to a smaller value, the transmit end may mistakenly regard that the link is faulty and the data transmission fails before the transmit end receives a response from the peer end. If timer N200 is set to a smaller value, the number of data retransmissions is reduced and the success rate of transmission is reduced. If timers T200 and N200 are set to greater values, the channels are seized all along when the link is faulty. Thus, resources are wasted. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If timer T200 is set to a smaller value, the transmit end may mistakenly regard that the link is faulty and the data transmission fails before the transmit end receives a response from the peer end. If timer N200 is set to a smaller value, the number of data retransmissions is reduced and the success rate of transmission is reduced. If timers T200 and N200 are set to greater values, the channels are seized all along when the link is faulty. Thus, resources are wasted. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If timer T200 is set to a smaller value, the transmit end may mistakenly regard that the link is faulty and the data transmission fails before the transmit end receives a response from the peer end. If timer N200 is set to a smaller value, the number of data retransmissions is reduced and the success rate of transmission is reduced. If timers T200 and N200 are set to greater values, the channels are seized all along when the link is faulty. Thus, resources are wasted. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If timer T200 is set to a smaller value, the transmit end may mistakenly regard that the link is faulty and the data transmission fails before the transmit end receives a response from the peer end. If timer N200 is set to a smaller value, the number of data retransmissions is reduced and the success rate of transmission is reduced. If timers T200 and N200 are set to greater values, the channels are seized all along when the link is faulty. Thus, resources are wasted. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If timer T200 is set to a smaller value, the transmit end may mistakenly regard that the link is faulty and the data transmission fails before the transmit end receives a response from the peer end. If timer N200 is set to a smaller value, the number of data retransmissions is reduced and the success rate of transmission is reduced. If timers T200 and N200 are set to greater values, the channels are seized all along when the link is faulty. Thus, resources are wasted. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If timer T200 is set to a smaller value, the transmit end may mistakenly regard that the link is faulty and the data transmission fails before the transmit end receives a response from the peer end. If timer N200 is set to a smaller value, the number of data retransmissions is reduced and the success rate of transmission is reduced. If timers T200 and N200 are set to greater values, the channels are seized all along when the link is faulty. Thus, resources are wasted. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If timer T200 is set to a smaller value, the transmit end may mistakenly regard that the link is faulty and the data transmission fails before the transmit end receives a response from the peer end. If timer N200 is set to a smaller value, the number of data retransmissions is reduced and the success rate of transmission is reduced. If timers T200 and N200 are set to greater values, the channels are seized all along when the link is faulty. Thus, resources are wasted. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a smaller value, the paging success rate increases but the load on the SDCCH also increases, thus causing congestion on the SDCCH. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, the handover cannot be performed in time and call drops may occur.If this parameter is set to a smaller value, unnecessary handovers may be performed. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, the handover cannot be performed in time and call drops may occur. If this parameter is set to a smaller value, the coverage area of the cell is reduced, and the traffic volume on the cell may be decreased. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. The access performance is affected. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, network congestion may occur in the cell; if this parameter is set to a smaller value, TCHHs are allocated even when the traffic volume on the cell is light, this affects the voice quality. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. When this parameter is set to a large value, the values of the new counters TCH call drops (DL FER) and TCH call drops (UL FER and DL FER) are reduced. When this parameter is set to a small value, the values of the two counters are increased. The overall number of call drops, however, remains unchanged and the performance of other counters is not affected. BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. When this parameter is set to a large value, the values of the new counters TCH call drops (DL receive level) and TCH call drops (UL receive level) are increased. When this parameter is set to a small value, the values of the two counters are reduced. The overall number of call drops, however, remains unchanged and the performance of other counters is not affected. BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. When this parameter is set to a large value, the values of the new counters TCH call drops (DL receive quality) and TCH call drops (UL receive quality and DL receive quality) are reduced. When this parameter is set to a small value, the values of the two counters are increased. The overall number of call drops, however, remains unchanged and the performance of other counters is not affected. BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. When this parameter is set to a large value, the values of the new counters TCH call drops (UL FER) and TCH call drops (UL FER and DL FER) are reduced. When this parameter is set to a small value, the values of the two counters are increased. The overall number of call drops, however, remains unchanged and the performance of other counters is not affected. BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. When this parameter is set to a large value, the values of the new counters TCH call drops (UL receive level) and TCH call drops (UL receive level and DL receive level) are increased. When this parameter is set to a small value, the values of the two counters are reduced. The overall number of call drops, however, remains unchanged and the performance of other counters is not affected. BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. When this parameter is set to a large value, the values of the new counters TCH call drops (UL receive quality) and TCH call drops (UL receive quality and DL receive quality) are reduced. When this parameter is set to a small value, the values of the two counters are increased. The overall number of call drops, however, remains unchanged and the performance of other counters is not affected. BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, the handover cannot be performed in time and call drops may occur. If this parameter is set to a smaller value, unexpected handovers may be performed due to incorrect MR when the call is initially set up, thus affecting handover success rate. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a smaller value, the handover frequency is higher. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to ON, the calls are handed over on schedule. This increases the load of the BSC but improves the network security. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, the half-rate channels are assigned to the MS only when the channel seizure ratio of underlaid subcell is very high. Insufficient half-rate channels can be assigned to the MS. Thus, the capacity of the BSC is reduced.If this parameter is set to a smaller value, the half-rate channels are assigned to the MS only when the channel seizure ratio of underlaid subcell is very low. The calls use the half-rate channel even if there are enough full-rate channels, which influences the voice quality. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, the half-rate channels are assigned to the MS only when the channel seizure ratio of overlaid subcell is very high. Insufficient half-rate channels can be assigned to the MS. Thus, the capacity of the BSC is reduced.If this parameter is set to a smaller value, the half-rate channels are assigned to the MS only when the channel seizure ratio of overlaid subcell is very low. The calls use the half-rate channel even if there are enough full-rate channels, which influences the voice quality. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
Not involved None BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
5/5/2014
Confidential Information of Huawei.
No Spreading without Permission
Page39of42
226347869.xls.ms_office Security Level:
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The radio link should be re-established after the parameter modification. If both TFO and AEC functions are enabled and the acoustic echo is detected, the TFO is disabled to cancel the echo so that the speech quality can be improved. BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, the BCCH may idle while non-BCCHs are congested, thus affecting the traffic volume during busy times.If this parameter is set to a smaller value, the assignment of the BCCH may fail, and thus the access success rate may be decreased. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, the assignment of the BCCH may fail, and thus the handover success rate may be decreased.If this parameter is set to a smaller value, the BCCH may idle while non-BCCHs are congested, thus affecting the traffic volume during busy times. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, the BCCH may idle while non-BCCHs are congested, thus affecting the traffic volume during busy times and the access success rate.If this parameter is set to a smaller value, unnecessary handovers may be performed, thus the voice quality is decreased. BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
Not involved None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, cell congestion may be difficult to be relieved, thus affecting the traffic volume during busy times and the access success rate. If this parameter is set to a smaller value, handover success rate may be decreased. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, it is difficult for the MS to be handed over to the original cell, thus leading to call drop when there is no suitable neighboring cell. If this parameter is set to a smaller value, the MS is likely to be handed over to the original cell again, thus leading to ping-pong handovers. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, call drop rate may be increased and congestion may occur in the overlaid subcell; if this parameter is set to a smaller value, handover success rate may be decreased. Versions earlier than BSC6900 V900R011 Radio
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, it is difficult for the MS to be handed over to the original cell, thus leading to call drop when there is no suitable neighboring cell. If this parameter is set to a smaller value, the MS is likely to be handed over to the original cell again, thus leading to ping-pong handovers. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, it is difficult for the MS to be handed over to the original cell, thus leading to call drop when there is no suitable neighboring cell. If this parameter is set to a smaller value, the MS is likely to be handed over to the original cell again, thus leading to ping-pong handovers. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, congestion may occur in the underlaid subcell; if this parameter is set to a smaller value, handover success rate may be decreased. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
Not involved None Versions earlier than BSC6900 V900R011 Transport
The BTS should be reset to validate the parameter modification. None Versions earlier than BSC6900 V900R011 Transport
Not involved None BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The cell should be reset to validate the parameter modification. None Versions earlier than BSC6900 V900R011 Radio
Not involved None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The BTS should be reset to validate the parameter modification. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
After this parameter is modified, the services in the cell are handed over forcedly. The cell is reset (after ten seconds) after the handover succeeds. This protects the services from being interrupted. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Equipment
Not involved Not involved Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
Not involved None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The transport path should be re-established after the parameter modification. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The transport path should be re-established after the parameter modification. None BSC6900 V900R011 Transport
The cell should be reset to validate the parameter modification. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The transport path should be re-established after the parameter modification. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. When this parameter is enabled, the fast flux monitoing frequency is increased, and the channel allocation can be adjusted more quickly to adapt to the service type. Thus, the terminal throughput and BSC PS resource usage can be increased. BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
Not involved Not involved Versions earlier than BSC6900 V900R011 Equipment
5/5/2014
Confidential Information of Huawei.
No Spreading without Permission
Page40of42
226347869.xls.ms_office Security Level:
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If the number of RACH conflicts in a cell is small, T should be set to a great value. If the number of RACH conflicts in a cell is large, T should be set to a small value. The increase in T and S prolongs the access time of an MS, thus affecting the access performance of the whole network. Therefore, appropriate values should be selected for T and S.When the network traffic is heavy, the success rate of immediate assignment is low if the sum of S and T is low. Thus, the value of T should be properly adjusted to make the sum of S and T great. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. Not involved Versions earlier than BSC6900 V900R011 Equipment
The cell should be activated after the parameter modification. None Versions earlier than BSC6900 V900R011 Radio
The BSC should be reset to validate the parameter modification. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
Not involved None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, the handover cannot be performed in time and call drops may occur.If this parameter is set to a smaller value, unnecessary handovers may be performed. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, unnecessary handovers may be performed.If this parameter is set to a smaller value, the handover cannot be performed in time and call drops may occur. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a smaller value, call drops may occur due to delayed handover; if this parameter is set to a greater value, unnecessary handover may be performed, thus affecting the voice quality. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a smaller value, downward power control is not performed when the signal quality is good, thus causing power waste and increasing the interference. If this parameter is set to a greater value, downward power control is performed even though the signal quality is bad, thus affecting the speech quality. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, upward power control may not be performed when the voice quality is bad, thus affecting the voice quality. If this parameter is set to a smaller value, upward power control may be performed when the voice quality is good, thus causing the power waste and increasing the interference. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, handover may not be performed when the uplink voice quality is bad, thus leading to call drops. If this parameter is set to a smaller value, unnecessary handovers may be performed, thus affecting the voice quality. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a smaller value, the handovers due to bad uplink quality may increase, thus decreasing the handover success rate. If this parameter is set to a greater value, handovers due to bad uplink quality are less possible to occur, thus increasing the call drop rate. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a smaller value, the handovers due to bad uplink quality may increase, thus decreasing the handover success rate. If this parameter is set to a greater value, handovers due to bad uplink quality are less possible to occur, thus increasing the call drop rate. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, downward power control may not be performed when the voice quality is good, thus causing the power waste and increasing the interference. If this parameter is set to a smaller value, downward power control may be performed when the voice quality is bad, thus affecting the voice quality. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, upward power control may be performed when the voice quality is good, thus causing the power waste and increasing the interference. If this parameter is set to a smaller value, upward power control may not be performed when the voice quality is bad, thus affecting the voice quality. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, downward power control may not be performed when the voice quality is good, thus causing the power waste and increasing the interference. If this parameter is set to a smaller value, downward power control may be performed when the voice quality is bad, thus affecting the voice quality. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, upward power control may be performed when the voice quality is good, thus causing the power waste and increasing the interference. If this parameter is set to a smaller value, upward power control may not be performed when the voice quality is bad, thus affecting the voice quality. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. The coding rate and MOS are affected. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. The coding rate and MOS are affected. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. The coding rate and MOS are affected. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, call drops may occur due to no suitable neighboring cell for handover. If this parameter is set to a smaller value, handover success rate may be decreased. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The transport path should be re-established after the parameter modification. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
Not involved Not involved Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The transport path should be re-established after the parameter modification. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, the handover cannot be performed in time and call drops may occur.If this parameter is set to a smaller value, unnecessary handovers may be performed, thus affecting the voice quality. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, unnecessary handovers may be performed, thus affecting the voice quality.If this parameter is set to a smaller value, the handover cannot be performed in time and call drops may occur. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, congestion may occur in the underlaid subcell.If this parameter is set to a smaller value, ping-pong handovers may occur. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, congestion in the underlaid subcell is difficult to be relieved; if this parameter is set to a smaller value, congestion may occur in the overlaid subcell in a short time. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, congestion may occur in the overlaid subcell in a short time; if this parameter is set to a smaller value, congestion in the underlaid subcell is difficult to be relieved. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
5/5/2014
Confidential Information of Huawei.
No Spreading without Permission
Page41of42
226347869.xls.ms_office Security Level:
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
Not involved Not involved Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, channel resources may be wasted, thus causing congestion. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, channel resources may be wasted, thus causing congestion. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. If this parameter is set to a greater value, channel resources may be wasted, thus causing congestion. Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Radio
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Radio
Not involved None Versions earlier than BSC6900 V900R011 Transport
The parameter modification has no impact on the equipment. None Versions earlier than BSC6900 V900R011 Equipment
5/5/2014
Confidential Information of Huawei.
No Spreading without Permission