You are on page 1of 2

Features

According to European standard EN 837-1:1998

Accuracy class 1.0.

100% working area at stable working pressure.

Alternative measurement system covers several measu-


rement media in practical operations.

Long life and high reliability through specially treated


spring material and robust mechanism of stainless steel.
Accessories
Pressure transducer
Gauge pulsation damper
Siphons
Connector
MIP10
Pressure gauge class 1.0 100%
Measurement system Pressure limits Installation* Connection Designation
Material standard
Tubular spring: C type bronze Overpressure: lowest 060 kPa 2 R 3/8 4112-3
Spring mounting: brass max. 06 MPa 2 R 1/2 4112-4
Joint: soldered Underpressure: 1000 kPa 5 R 3/8 4115-3
Over- and min. -10060 kPa 5 R 1/2 4115-4
underpressure: max 10001500 kPa 7 R 3/8 4117-3
7 R 1/2 4117-4
Tubular spring: C type/Screw Overpressure: min. 0-100 kPa 2 R 3/8 4312-3
ss SS 2343 max. 0160 MPa 2 R 1/2 4312-4
Spring mounting: ss SS 2343 Underpressure: 1000 kPa 5 R 3/8 4315-3
Joint: welded ss Over- and min. -100060 kPa 5 R 1/2 4315-4
underpressure: max 10001500 kPa 7 R 3/8 4317-3
7 R 1/2 4317-4
Overpressure > 10 MPa = Screw type
* Installation 2 = free-standing, stud downwards.
5 = surface mounted, flange at rear edge, stud downwards.
7 = recessed flange at front edge, stud backwards, with bracket.
Technical specification
Size 100 mm, see figure below.
Measurement C type bourdon tube, bronze or
system/ stainless steel AIS 316. See table
Material page 1.
Pressure limits For respective measurement
systems, see table page 1.
Mechanism Stainless steel.
Scale Centric scale on white background,
black graduation and text, 270
deflection of pointer and scale
length 180 mm.
Graduation The gauge is supplied as standard
graduated in Pascal with the second-
ary scale in bar on a yellow back-
ground (Yellow points). Single gradua-
tion in Pascal or bar is available. The
standard scale range can be found
on data sheet 493-1040-01 (min.
and max. for respective measurement
systems, see table on page 1).
Inaccuracy Max. deviation 1% of the scale
range.
Load capacity
Permitted load 100% at stable working pressure,
88% at variable working pressure.
Overload 130% of the scale range.
Housing Blue zinc-plated sheet steel housing.
Front ring Black zinc/plated sheet steel front-
ring, bayonet fitting.
Glass Lexan 121R, Polycarbonate.
Installation See below.
Connection Standard R 3/8 and R 1/2, fitted with
restrictor from 06 MPa and higher.
Working Max. +100C (with soldered
temperature measurement system max. +50C).
Weight Approx. 0.5 kg.
Order example
MIP10-4112-3
Size: 100 mm
Scale range: 01 MPa/010 bar
Connection: R 3/8
Specifications subject to change without notice.
Printed in Sweden. 2000 ABB Automation Products AB.
493-1003-11
0011 v.2.2
ABB Instrumentation
a unit within ABB Automation Products AB
SE-147 80 Tumba, Sweden.
Tel: +46 8 530 661 00
Fax: +46 8 530 666 89
www.abb.com/se
Panel cut-out 102+2
5 2 7
Installation method and connection standard.
R
1
/2 3 20 88 6.0
R
3
/8 3 16 84 5.5
d f g h j
33
65R 3/8
69R 1/2
53
110
33
13
110
19.5
N17
j
d
f
g
h
134
118
6.0
46 5.5

You might also like