You are on page 1of 1

ANG. VERT.

T329-T328

LINEA PARAMONGA - CHIMBOTE


TRAMO T329-T328
REGULADO DEL CABLE CONDUCTOR UTILIZANDO VISUAL TANGENTE DESDE EL PISO
TRAMO A REGU.
Vano de Control
Fijacin
Numeracion
Teodolito en Torre
Torre Visado
Vano (a)
Vano Regulador
Altura Instrumen.
Peso Conductor

329
329

a
a

328
328
ECUACION DE LA CATENARIA : Y = h Cosh ( X/h)

Final
329
328
595.12
595.12

1.43
1.308

Campo
329
328

FD(Flecha Directa) =

TH
P

COSH

m
m
m
kg/m

axP
2 x TH

-1

TH=Tensin Horizontal
P= Peso esp. Cable
a= Vano
TABLA DE TORRES

FI
COTA DE AMARRE(T329)
COTA DE AMARRE(T328)
DESNIVELES (DH)
FLECHAS TENSION
TEMPERATURA
DIRECTAS
Kg

FM

FS

23.84
29.15
34.37
111.60
116.79
122.19
87.77
87.64
87.82
ANGULOS DE CONTROL
CONDUCTOR CONDUCTOR CONDUCTOR
INFERIOR
MEDIO
SUPERIOR

16 C

28.64

2049.54

1566.93

82

33

36

81

31

37

80

34

40

17 C

28.69

2045.90

1564.14

82

34

13

81

32

11

80

35

11

18 C

28.75

2042.26

1561.36

82

34

58

81

32

51

80

35

47

19 C

28.80

2038.64

1558.59

82

35

35

81

33

25

80

36

18

20 C

28.85

2035.03

1555.83

82

36

12

81

33

58

80

36

49

21 C

28.90

2031.44

1553.09

82

36

49

81

34

32

80

37

19

22 C

28.95

2027.85

1550.34

82

37

27

81

35

80

37

50

23 C

29.00

2024.28

1547.61

82

38

81

35

40

80

38

21

24 C

29.05

2020.73

1544.90

82

38

41

81

36

14

80

38

52

OHL 020

Elaboro

Aprobo

FLECHADO EN CAMPO
CONDUCTOR CONDUCTOR CONDUCTOR
INFERIOR
MEDIO
SUPERIOR

Compaa
ANG. POLEA

Topografo:

F. REAL
FLECHA
%

82 33' 37''

81 30' 57''

80 34' 40''

Inf.
79 22' 45''
29.41
0.77
2.7%

Rev. 0
Med.
78 53' 50''
29.28
0.64
2.2%

Sup.
78 23' 50''
28.64
0.00
0.0%