Professional Documents
Culture Documents
CONCRETE CLASS
OPC POST TENSIONED 50/20
DATE
2/15/2007
1.OP Cement
OP Cement S.G.
Microsilica
Microsilica S.G.
420.000
3.150
30.000
2.350
kg
0.146
m3
0.320
Water volume
0.144
kg
m3
Glenium 110M
4.400
ltr
4.822
1.096
1.03%
0.004
m3
kg
0.008
m3
0.8%
8.000
Volume of Paste
0.302
m3
5. Volume of Aggregates
0.698
m3
20 mm
10 mm
Qatar sand
691.937
422.278
823.614
1937.829
kg
kg
kg
kg
2.917
0.647
0.36
%
%
5a. 20mm
S.G. SSD
water absorption
moisture content
uncorrected
volume
weight
0.249
726.672
5b. 10mm
S.G.SSD
water absorption
moisture content
2.924
0.886
1.52
m3
kg
%
%
34.0%
20.7%
45.3%
100.0%
uncorrected
volume
weight
0.152
444.541
2.606
1.458
6.400
m3
kg
%
%
uncorrected
volume
weight
0.297
772.741
m3
kg
VOLUME TOTALS
OP Cement + Microsilica
Water
Glenium 110M
Air Voids
20 mm Aggregate
10 mm Aggregate
Qatar Sand
uncorrected
0.146
0.144
0.004
0.008
0.249
0.152
0.297
corrected
0.146
0.164
0.004
0.008
0.242
0.148
0.288
3
1.000 m
1.000
Absorbed Water
20 mm Aggregate
10 mm Aggregate
Qatar Sand
4.702
3.939
11.267
kg
kg
kg
19.907
0.020
kg
m3
0.322
0.678
m3
m3
m3
m3
m3
m3
m3
m3
m3
WEIGHT TOTALS
OP Cement + Microsilica
Water
Glenium 110M
20 mm Aggregate
10 mm Aggregate
Qatar Sand
uncorrected
450.0
144.0
4.635
726.7
444.5
772.7
Moisture
Content
450.0
58.8
4.635
2.6
6.8
49.5
Moisture
corrected
450.0
105.1
4.635
729.3
451.3
822.2
TOTALS
W/C
2542.6
0.320
Glenium 110M
2562.5
1.03%
Date________________
Date________________
15/02/07
The Pearl Qatar - Roads and Infrastructure
(CP2-1) BRIDGES
20 mm Gabbro Moisture:
0.36 %
10 mm Gabbro Moisture:
1.52 %
Sand Moisture:
6.40 %
WEIGHT TOTALS
OPC + Microsilica
Mix Design
Absorbed
Moisture
BATCH
Weights
Water
Weights
WEIGHTS
450
450.0
144.0
Glenium 110M
4.6
20 mm Aggregate
726.7
4.7
2.6
729
10 mm Aggregate
444.5
3.9
6.8
451
Qatar Sand
772.7
11.3
49.5
822
TOTALS
2542.6
W/C
0.32
Laboratory Engineer
19.9
58.8
105
Water
1.03%
2562
BS 410
20mm Gabbro
10mm Gabbro
Qatar Sand
SIEVE SIZE
Individual
Blended
Individual
Blended
Individual
mm
100.0%
34.0%
100.0%
20.7%
100.0%
0.075
1.1%
0.4%
1.0%
0.2%
2.0%
0.150
1.1%
0.4%
1.0%
0.2%
3.2%
0.300
1.1%
0.4%
1.0%
0.2%
18.2%
0.600
1.1%
0.4%
1.5%
0.3%
59.0%
1.18
1.1%
0.4%
2.1%
0.4%
82.5%
2.36
1.1%
0.4%
2.5%
0.5%
91.1%
5.0
2.5%
0.9%
11.7%
2.4%
97.2%
10.0
8.1%
2.8%
98.2%
20.3%
100.0%
14.0
34.8%
11.8%
100.0%
20.7%
100.0%
20.0
93.1%
31.7%
100.0%
20.7%
100.0%
37.5
100.0%
34.0%
100.0%
20.7%
100.0%
90%
80%
70%
60%
50%
40%
30%
0.600
20%
10%
0%
0.075 0.150
BS 410 Sieve Size, mm
34.0% 20 mm
20.7% 10 mm
45.3% sand
100.0%
Blended
Combined
Grading
SUM
45.3%
100.0%
0.9%
1.5%
0.0%
TO
4.0%
1.4%
2.0%
0.0%
TO
8.0%
10.0%
TO
35.0%
35.0%
TO
55.0%
Qatar Sand
8.2%
8.8%
26.7%
27.4%
37.4%
38.2%
41.3%
42.2%
44.0%
47.3%
45.3%
68.4%
45.3%
77.8%
Specification
45.3%
97.7%
95.0%
TO
100.0%
45.3%
100.0%
100.0%
TO
100.0%
20.0
5.0
0.600
37.5
2/15/2007
1.OP Cement
OP Cement S.G.
Microsilica
Microsilica S.G.
280.000
3.150
0.000
2.350
kg
0.089
m3
0.500
Water volume
0.140
kg
m3
Glenium 110M
4.400
ltr
5.412
1.230
2.00%
0.005
m3
kg
0.010
m3
1.0%
8.000
Volume of Paste
0.243
m3
5. Volume of Aggregates
0.757
m3
20 mm
10 mm
Qatar sand
739.305
497.740
867.500
2104.545
kg
kg
kg
kg
2.917
0.647
0.68
%
%
5a. 20mm
S.G. SSD
water absorption
moisture content
uncorrected
volume
weight
0.266
775.254
5b. 10mm
S.G.SSD
water absorption
moisture content
2.924
0.886
1.52
m3
kg
%
%
33.5%
22.5%
44.0%
100.0%
uncorrected
volume
weight
0.179
523.195
2.606
1.458
6.400
m3
kg
%
%
uncorrected
volume
weight
0.312
812.696
m3
kg
VOLUME TOTALS
OP Cement + Microsilica
Water
Glenium 110M
Air Voids
20 mm Aggregate
10 mm Aggregate
Qatar Sand
uncorrected
0.089
0.140
0.005
0.010
0.266
0.179
0.312
corrected
0.089
0.162
0.005
0.010
0.258
0.174
0.303
3
1.000 m
1.000
Absorbed Water
20 mm Aggregate
10 mm Aggregate
Qatar Sand
5.016
4.636
11.849
kg
kg
kg
21.501
0.022
kg
m3
0.265
0.735
m3
m3
m3
m3
m3
m3
m3
m3
m3
WEIGHT TOTALS
OP Cement + Microsilica
Water
Glenium 110M
20 mm Aggregate
10 mm Aggregate
Qatar Sand
uncorrected
280.0
140.0
5.600
775.3
523.2
812.7
Moisture
Content
280.0
65.2
5.600
5.3
8.0
52.0
Moisture
corrected
280.0
96.3
5.600
780.5
531.1
864.7
TOTALS
W/C
2536.7
0.500
Rheobuild 857
2558.2
2.00%
Date________________
Date________________
25 / 20 BLINDING CONCRETE
Date:
Used For:
15/02/07
The Pearl Qatar
(CP2-1)
20 mm Gabbro Moisture:
0.36 %
10 mm Gabbro Moisture:
1.52 %
6.40 %
WEIGHT TOTALS
OPC + Microsilica
Mix Design
Absorbed
Moisture
BATCH
Weights
Water
Weights
WEIGHTS
280
280.0
140.0
Rheobuild 857
5.6
20 mm Aggregate
775.3
5.0
5.3
781
10 mm Aggregate
523.2
4.6
8.0
531
Qatar Sand
812.7
11.8
52.0
865
TOTALS
2536.7
W/C
0.50
Laboratory Engineer
21.5
65.2
96
Water
2.00%
2558
BS 410
Glenium 110M
20mm Gabbro
10mm Gabbro
Qatar Sand
SIEVE SIZE
Individual
Blended
Individual
Blended
Individual
mm
100.0%
33.5%
100.0%
22.5%
100.0%
0.075
1.1%
0.4%
1.0%
0.2%
2.0%
0.150
1.1%
0.4%
1.0%
0.2%
3.2%
0.300
1.1%
0.4%
1.0%
0.2%
18.2%
0.600
1.1%
0.4%
1.5%
0.3%
59.0%
1.18
1.1%
0.4%
2.1%
0.5%
82.5%
2.36
1.1%
0.4%
2.5%
0.6%
91.1%
5.0
2.5%
0.8%
11.7%
2.6%
97.2%
10.0
8.1%
2.7%
98.2%
22.1%
100.0%
14.0
34.8%
11.7%
100.0%
22.5%
100.0%
20.0
93.1%
31.2%
100.0%
22.5%
100.0%
37.5
100.0%
33.5%
100.0%
22.5%
100.0%
100%
90%
80%
70%
60%
50%
40%
30%
0.600
20%
10%
0%
0.075 0.150
33.5% 20 mm
22.5% 10 mm
44.0% sand
100.0%
Blended
Combined
Grading
SUM
44.0%
100.0%
0.9%
1.5%
0.0%
TO
4.0%
1.4%
2.0%
0.0%
TO
8.0%
10.0%
TO
35.0%
35.0%
TO
55.0%
Qatar Sand
8.0%
8.6%
26.0%
26.7%
36.3%
37.1%
40.1%
41.0%
42.8%
46.2%
44.0%
68.8%
44.0%
78.2%
Specification
44.0%
97.7%
95.0%
TO
100.0%
44.0%
100.0%
100.0%
TO
100.0%
20.0
5.0
0.600
37.5
2/15/2007
1.OP Cement
OP Cement S.G.
Microsilica
Microsilica S.G.
390.000
3.150
30.000
2.350
kg
0.137
m3
0.330
Water volume
0.139
kg
m3
Glenium 110M
4.400
ltr
4.822
1.096
0.93%
0.004
m3
kg
0.010
m3
1.0%
8.000
Volume of Paste
0.289
m3
5. Volume of Aggregates
0.711
m3
20 mm
10 mm
Qatar sand
684.667
478.337
815.560
1978.564
kg
kg
kg
kg
2.917
0.647
0.36
%
%
5a. 20mm
S.G. SSD
water absorption
moisture content
uncorrected
volume
weight
0.246
717.950
5b. 10mm
S.G.SSD
water absorption
moisture content
2.924
0.886
1.52
m3
kg
%
%
33.0%
23.0%
44.0%
100.0%
uncorrected
volume
weight
0.172
502.794
2.606
1.458
6.400
m3
kg
%
%
uncorrected
volume
weight
0.293
764.028
m3
kg
VOLUME TOTALS
OP Cement + Microsilica
Water
Glenium 110M
Air Voids
20 mm Aggregate
10 mm Aggregate
Qatar Sand
uncorrected
0.137
0.139
0.004
0.010
0.246
0.172
0.293
corrected
0.137
0.159
0.004
0.010
0.239
0.167
0.285
3
1.000 m
1.000
Absorbed Water
20 mm Aggregate
10 mm Aggregate
Qatar Sand
4.645
4.455
11.140
kg
kg
kg
20.239
0.020
kg
m3
0.309
0.691
m3
m3
m3
m3
m3
m3
m3
m3
m3
WEIGHT TOTALS
OP Cement + Microsilica
Water
Glenium 110M
20 mm Aggregate
10 mm Aggregate
Qatar Sand
uncorrected
420.0
138.6
3.906
718.0
502.8
764.0
Moisture
Content
420.0
59.1
3.906
2.6
7.6
48.9
Moisture
corrected
420.0
99.7
3.906
720.5
510.4
812.9
TOTALS
W/C
2547.3
0.330
Glenium 110M
2567.5
0.93%
Date________________
Date________________
40 / 20 REINFORCED CONCRETE
Date:
Used For:
15/02/07
The Pearl Qatar
(CP2-1)
20 mm Gabbro Moisture:
0.36 %
10 mm Gabbro Moisture:
1.52 %
Sand Moisture:
6.40 %
WEIGHT TOTALS
OPC + Microsilica
Mix Design
Absorbed
Moisture
BATCH
Weights
Water
Weights
WEIGHTS
420
420.0
138.6
Glenium 110M
3.9
20 mm Aggregate
718.0
4.6
2.6
721
10 mm Aggregate
502.8
4.5
7.6
510
Qatar Sand
764.0
11.1
48.9
813
TOTALS
2547.3
W/C
0.33
Laboratory Engineer
20.2
59.1
100
Water
0.93%
2568
BS 410
20mm Gabbro
10mm Gabbro
Qatar Sand
SIEVE SIZE
Individual
Blended
Individual
Blended
Individual
mm
100.0%
33.0%
100.0%
23.0%
100.0%
0.075
1.1%
0.4%
1.0%
0.2%
2.0%
0.150
1.1%
0.4%
1.0%
0.2%
3.2%
0.300
1.1%
0.4%
1.0%
0.2%
18.2%
0.600
1.1%
0.4%
1.5%
0.3%
59.0%
1.18
1.1%
0.4%
2.1%
0.5%
82.5%
2.36
1.1%
0.4%
2.5%
0.6%
91.1%
5.0
2.5%
0.8%
11.7%
2.7%
97.2%
10.0
8.1%
2.7%
98.2%
22.6%
100.0%
14.0
34.8%
11.5%
100.0%
23.0%
100.0%
20.0
93.1%
30.7%
100.0%
23.0%
100.0%
37.5
100.0%
33.0%
100.0%
23.0%
100.0%
100%
90%
80%
70%
60%
50%
40%
30%
0.600
20%
10%
0%
0.075 0.150
33.0% 20 mm
23.0% 10 mm
44.0% sand
100.0%
Blended
Combined
Grading
SUM
44.0%
100.0%
0.9%
1.5%
0.0%
TO
4.0%
1.4%
2.0%
0.0%
TO
8.0%
10.0%
TO
35.0%
35.0%
TO
55.0%
Qatar Sand
8.0%
8.6%
26.0%
26.7%
36.3%
37.1%
40.1%
41.0%
42.8%
46.3%
44.0%
69.3%
44.0%
78.5%
Specification
44.0%
97.7%
95.0%
TO
100.0%
44.0%
100.0%
100.0%
TO
100.0%
20.0
5.0
0.600
37.5
1/26/2007
1.OP Cement
OP Cement S.G.
Microsilica
Microsilica S.G.
280.000
3.150
0.000
2.350
kg
0.089
m3
0.480
Water volume
0.134
kg
m3
Glenium 110M
4.400
ltr
5.412
1.230
2.00%
0.005
m3
kg
0.010
m3
1.0%
8.000
Volume of Paste
0.238
m3
5. Volume of Aggregates
0.762
m3
20 mm
10 mm
Qatar sand
0.000
999.075
1094.078
2093.153
kg
kg
kg
kg
2.917
0.667
0.68
%
%
5a. 20mm
S.G. SSD
water absorption
moisture content
uncorrected
volume
weight
0.000
0.000
m3
kg
5b. 10mm
S.G.SSD
water absorption
moisture content
2.913
0.863
1.46
%
%
0.0%
45.0%
55.0%
100.0%
uncorrected
volume
weight
0.364
1059.700
2.610
1.245
6.100
m3
kg
%
%
uncorrected
volume
weight
0.398
1039.760
m3
kg
VOLUME TOTALS
OP Cement + Microsilica
Water
Glenium 110M
Air Voids
20 mm Aggregate
10 mm Aggregate
Qatar Sand
uncorrected
0.089
0.134
0.005
0.010
0.000
0.364
0.398
corrected
0.089
0.156
0.005
0.010
0.000
0.353
0.387
3
1.000 m
1.000
Absorbed Water
20 mm Aggregate
10 mm Aggregate
Qatar Sand
0.000
9.145
12.945
kg
kg
kg
22.090
0.022
kg
m3
0.260
0.740
m3
m3
m3
m3
m3
m3
m3
m3
m3
WEIGHT TOTALS
OP Cement + Microsilica
Water
Glenium 110M
20 mm Aggregate
10 mm Aggregate
Qatar Sand
uncorrected
280.0
134.4
5.600
0.0
1059.7
1039.8
Moisture
Content
280.0
78.9
5.600
0.0
15.5
63.4
TOTALS
W/C
2519.5
0.480
Rheobuild 857
Date________________
Date________________
Moisture
corrected
280.0
77.6
5.600
0.0
1075.2
1103.2
2541.5
2.00%
25 / 10 SCREED CONCRETE
Date:
Used For:
26/01/07
The Pearl Qatar
(CP2-1)
20 mm Gabbro Moisture:
0.53 %
10 mm Gabbro Moisture:
1.46 %
6.10 %
WEIGHT TOTALS
OPC + Microsilica
Mix Design
Absorbed
Moisture
BATCH
Weights
Water
Weights
WEIGHTS
280
280.0
Water
134.4
Rheobuild 857
5.6
22.1
78.9
78
2.00%
20 mm Aggregate
10 mm Aggregate
1059.7
9.1
15.5
1075
Qatar Sand
1039.8
12.9
63.4
1103
TOTALS
2519.5
W/C
0.48
Laboratory Engineer
2542
BS 410
Glenium 110M
20mm Gabbro
10mm Gabbro
Qatar Sand
SIEVE SIZE
Individual
Blended
Individual
Blended
Individual
mm
100.0%
0.0%
100.0%
45.0%
100.0%
0.075
1.1%
0.0%
1.1%
0.5%
1.4%
0.150
1.1%
0.0%
1.1%
0.5%
4.3%
0.300
1.1%
0.0%
1.1%
0.5%
20.5%
0.600
1.1%
0.0%
1.3%
0.6%
59.1%
1.18
1.1%
0.0%
1.5%
0.7%
84.4%
2.36
1.1%
0.0%
2.0%
0.9%
93.4%
5.0
1.8%
0.0%
14.7%
6.6%
98.6%
10.0
6.1%
0.0%
96.7%
43.5%
100.0%
14.0
31.2%
0.0%
100.0%
45.0%
100.0%
20.0
93.0%
0.0%
100.0%
45.0%
100.0%
37.5
100.0%
0.0%
100.0%
45.0%
100.0%
0.0% 20 mm
45.0% 10 mm
55.0% sand
100.0%
Blended
Combined
Grading
SUM
55.0%
100.0%
0.8%
1.3%
0.0%
TO
4.0%
2.4%
2.9%
0.0%
TO
8.0%
11.3%
11.8%
32.5%
33.1%
10.0%
TO
35.0%
46.4%
47.1%
51.4%
52.3%
54.2%
60.8%
35.0%
TO
55.0%
55.0%
98.5%
55.0%
100.0%
55.0%
100.0%
95.0%
TO
100.0%
55.0%
100.0%
100.0%
TO
100.0%
Qatar Sand
Specification
Glenium 110M
1.096
1.64%
6.000
ltr
3
0.006 m
Rheocrete 222+
1.000
1.25%
5.000
ltr
3
0.005 m
5.000
kg
0.010
1.0%
Volume of Paste
3
0.279 m
5. Volume of Aggregates
3
0.721 m
20 mm
10 mm
Qatar sand
5a. 20mm
S.G.
water absorption
moisture content
684.011
408.722
903.826
1996.560
kg
kg
kg
kg
2.929
0.584 %
0 %
uncorrected
volume
weight
6.576
kg
3
0.247 m
723.268 kg
32.4%
19.5%
48.1%
100.0%
5b. 10mm
S.G.
water absorption
moisture content
2.908
0.817 %
0 %
uncorrected
volume
weight
5c. Qatar Sand
S.G.
water absorption
moisture content
3
0.148 m
429.081 kg
2.607
1.554 %
6.900 %
uncorrected
volume
weight
3
0.326 m
850.634 kg
VOLUME TOTALS
OP Cement + Microsilica
Water
Glenium 110M
Rheocrete 222+
Air Voids
20 mm Aggregate
10 mm Aggregate
Qatar Sand
uncorrected
0.130
0.128
0.006
0.005
0.010
0.247
0.148
0.326
corrected
0.130
0.149
0.006
0.005
0.010
0.240
0.143
0.317
1.000
Absorbed Water
20 mm Aggregate
10 mm Aggregate
Qatar Sand
4.224 kg
3.506 kg
13.219 kg
20.948 kg
3
0.021 m
3
0.300 m
3
0.700 m
m3
m3
m3
m3
m3
m3
m3
m3
3
1.000 m
40 / 20 PILING CONCRETE
Date: 07/11/2006
Volume Required:
Used For: Bridge
Sand Moisture:
6.9 %
WEIGHT TOTALS
uncorrected
OP Cement + Microsilica
Absorption
Moisture
corrected
corrected
400.0
400.0
400.0
Water
128.0
148.9
92.0
Glenium 110M
5.600
5.600
1.40%
Rheocrete 222+
5.000
5.000
1.25%
20 mm Aggregate
723.3
702.2
702.2
10 mm Aggregate
429.1
416.6
416.6
Qatar Sand
850.6
825.9
882.9
TOTALS
2541.6
2504.3
2504.3
W/C
0.320
Laboratory Engineer
Date________________
Date________________
BS 410
20mm Gabbro
10mm Gabbro
Qatar Sand
SIEVE SIZE
Individual
Blended
Individual
Blended
Individual
mm
100.0%
32.4%
100.0%
19.5%
100.0%
0.075
0.6%
0.2%
1.1%
0.2%
2.1%
0.150
0.0%
0.0%
0.0%
0.0%
3.0%
0.300
0.0%
0.0%
0.0%
0.0%
12.9%
0.600
0.0%
0.0%
0.0%
0.0%
49.0%
1.18
0.0%
0.0%
1.2%
0.2%
73.7%
2.36
0.7%
0.2%
1.4%
0.3%
87.7%
5.0
0.8%
0.3%
12.2%
2.4%
97.3%
10.0
8.8%
2.9%
97.8%
19.1%
100.0%
14.0
46.0%
14.9%
100.0%
19.5%
100.0%
20.0
97.0%
31.4%
100.0%
19.5%
100.0%
37.5
100.0%
32.4%
100.0%
19.5%
100.0%
0.600
20%
10%
0%
0.075 0.150
BS 410 Sieve Size, mm
Blended
Combined
Grading
SUM
48.1%
100.0%
1.0%
1.4%
0.0%
TO
4.0%
1.4%
1.4%
0.0%
TO
8.0%
10.0%
TO
35.0%
35.0%
TO
55.0%
Qatar Sand
6.2%
6.2%
23.6%
23.6%
35.4%
35.7%
42.2%
42.7%
46.8%
49.4%
48.1%
70.0%
48.1%
82.5%
Specification
48.1%
99.0%
95.0%
TO
100.0%
48.1%
100.0%
100.0%
TO
100.0%
20.0
5.0
0.600
37.5
DATE
12/10/2006
Weight of OP Cement
645.0 kg
OP Cement SG
3.15
3
0.205 m
OP Cement Volume
Water Cement Ratio
Water weight
Water Volume
Air Voids
Volume of Air Voids
Volume of Paste
Volume of Sand
Sand SG
0.40
258.0 kg ( litres)
3
0.258 m
0.5 %
3
0.005 m
0.468 m3
3
0.532 m
2.61
Sand Moisture
7.5 %
Water Absorption
1.564 %
1389.1 kg
21.7 kg ( litres)
0.022 m
104.2 kg ( litres)
3
0.104 m
0.385 m3
0.176 m3
0.615 m3
3
1.000 m
Weight of OPC
645.0 kg
175.5 kg ( litres)
1604.4 kg
3.00
2507.4 kg
2.507 kg/m3
Date________________
Date________________
1.096
0.01 %
3
0.004 m
3
0.010 m
Volume of Paste
3
0.276 m
5. Volume of Aggregates
3
0.724 m
20 mm
10 mm
Qatar sand
5a. 20mm
S.G.
water absorption
moisture content
677.618
410.948
893.286
1981.852
kg
kg
kg
kg
2.926
0.521 %
0.62 %
uncorrected
volume
weight
5b. 10mm
S.G.
water absorption
moisture content
3
0.247 m
724.018 kg
2.912
0.76 %
1.44 %
Glenium 110M
4.400
ltr
4.822
kg
1.0%
32.0%
19.5%
48.5%
100.0%
uncorrected
volume
weight
5c. Qatar Sand
S.G.
water absorption
moisture content
3
0.150 m
436.986 kg
2.545
1.250 %
2.700 %
uncorrected
volume
weight
3
0.326 m
830.171 kg
VOLUME TOTALS
OP Cement + Microsilica
Water
Glenium 110M
Air Voids
20 mm Aggregate
10 mm Aggregate
Qatar Sand
uncorrected
0.130
0.132
0.004
0.010
0.247
0.150
0.326
corrected
0.130
0.149
0.004
0.010
0.241
0.146
0.318
1.000
Absorbed Water
20 mm Aggregate
10 mm Aggregate
Qatar Sand
3.772 kg
3.321 kg
10.377 kg
17.470 kg
3
0.017 m
3
0.294 m
3
0.706 m
m3
m3
m3
m3
m3
m3
m3
3
1.000 m
WEIGHT TOTALS
OP Cement + Microsilica
Water
Glenium 110M
20 mm Aggregate
10 mm Aggregate
Qatar Sand
uncorrected
400.000
132.000
4.461
724.018
436.986
830.171
TOTALS
W/C
2527.636
0.330
Absorption
corrected
400.000
149.470
4.461
706.540
426.437
810.131
Moisture
corrected
400.000
117.076
4.461
710.920
432.578
832.004
2497.039
2497.039
Date________________
Date________________
BS 410
Glenium 110M
20mm Gabbro
10mm Gabbro
Qatar Sand
SIEVE SIZE
Individual
Blended
Individual
Blended
Individual
mm
100.0%
32.0%
100.0%
19.5%
100.0%
0.075
0.1%
0.0%
0.0%
0.0%
2.5%
0.150
0.1%
0.0%
0.1%
0.0%
4.8%
0.300
0.1%
0.0%
0.1%
0.0%
20.7%
0.600
0.1%
0.0%
0.5%
0.1%
60.5%
1.18
0.1%
0.0%
0.5%
0.1%
83.9%
2.36
0.1%
0.0%
0.5%
0.1%
93.7%
5.0
0.1%
0.0%
14.5%
2.8%
98.8%
10.0
4.8%
1.5%
99.5%
19.4%
100.0%
14.0
35.7%
11.4%
100.0%
19.5%
100.0%
20.0
98.6%
31.6%
100.0%
19.5%
100.0%
37.5
100.0%
32.0%
100.0%
19.5%
100.0%
100%
90%
80%
70%
60%
50%
40%
30%
0.600
20%
10%
0%
0.075 0.150
BS 410 Sieve Size, mm
Blended
Combined
Grading
SUM
48.5%
100.0%
1.2%
1.2%
0.0%
TO
4.0%
2.3%
2.4%
0.0%
TO
8.0%
10.0%
10.1%
29.3%
29.5%
10.0%
TO
35.0%
40.7%
40.8%
45.4%
45.6%
47.9%
50.8%
35.0%
TO
55.0%
48.5%
69.4%
48.5%
79.4%
Qatar Sand
Specification
48.5%
99.6%
95.0%
TO
100.0%
48.5%
100.0%
100.0%
TO
100.0%
20.0
5.0
0.600
37.5
Glenium 110M
4.400
ltr
4.822
1.096
0.98%
3
0.004 m
kg
3
0.005 m
0.5%
8.000
Volume of Paste
3
0.290 m
5. Volume of Aggregates
3
0.710 m
20 mm
10 mm
Qatar sand
5a. 20mm
S.G.
water absorption
moisture content
0.000
1147.866
814.796
1962.661
kg
kg
kg
kg
2.911
0.674 %
0 %
uncorrected
volume
weight
5b. 10mm
S.G.
water absorption
moisture content
3
0.000 m
0.000 kg
2.889
1.145 %
0 %
0.0%
56.0%
44.0%
100.0%
uncorrected
volume
weight
5c. Qatar Sand
S.G.
water absorption
moisture content
3
0.415 m
1198.806 kg
2.610
1.564 %
6.500 %
uncorrected
volume
weight
3
0.295 m
768.775 kg
VOLUME TOTALS
OP Cement + Microsilica
Water
Glenium 110M
Air Voids
20 mm Aggregate
10 mm Aggregate
Qatar Sand
uncorrected
0.140
0.142
0.004
0.005
0.000
0.415
0.295
corrected
0.140
0.168
0.004
0.005
0.000
0.400
0.284
1.000
Absorbed Water
20 mm Aggregate
10 mm Aggregate
Qatar Sand
0.000 kg
13.726 kg
12.024 kg
25.750 kg
3
0.026 m
3
0.316 m
3
0.684 m
m3
m3
m3
m3
m3
m3
m3
3
1.000 m
WEIGHT TOTALS
OP Cement + Microsilica
Water
Glenium 110M
20 mm Aggregate
10 mm Aggregate
Qatar Sand
TOTALS
W/C
Absorption
corrected
430.0
167.6
4.214
0.0
1155.3
740.9
Moisture
corrected
430.0
119.5
4.214
0.0
1155.3
789.0
2543.7
2498.0
0.330 Glenium 110M
2498.0
0.98%
uncorrected
430.0
141.9
4.214
0.0
1198.8
768.8
Date________________
Date________________
40 / 10 REINFORCED CONCRETE
Date:
13/12/06
m3
Volume Required:
Used For:
Sand Moisture:
WEIGHT TOTALS
uncorrected
OP Cement + Microsilica
Absorption
Moisture
corrected
corrected
430.0
430.0
430.0
Water
141.9
167.6
119.5
Glenium 110M
4.2
4.2
0.98%
20 mm Aggregate
0.0
0.0
0.0
10 mm Aggregate
1198.8
1155.3
1155.3
Qatar Sand
768.8
740.9
789.0
TOTALS
2543.7
2498.0
2498.0
W/C
0.33
Laboratory Engineer
BS 410
Glenium 110M
20mm Gabbro
10mm Gabbro
Qatar Sand
SIEVE SIZE
Individual
Blended
Individual
Blended
Individual
mm
100.0%
0.0%
100.0%
56.0%
100.0%
0.075
0.7%
0.0%
1.0%
0.6%
1.8%
0.150
0.0%
0.0%
0.0%
0.0%
2.9%
0.300
0.0%
0.0%
1.0%
0.6%
14.0%
0.600
0.0%
0.0%
2.1%
1.2%
56.0%
1.18
0.0%
0.0%
2.5%
1.4%
79.5%
2.36
0.6%
0.0%
3.0%
1.7%
90.4%
5.0
2.3%
0.0%
15.7%
8.8%
97.9%
10.0
11.4%
0.0%
98.6%
55.2%
100.0%
14.0
46.2%
0.0%
100.0%
56.0%
100.0%
20.0
98.4%
0.0%
100.0%
56.0%
100.0%
37.5
100.0%
0.0%
100.0%
56.0%
100.0%
100%
90%
80%
70%
60%
50%
40%
30%
0.600
20%
10%
0%
0.075 0.150
0.0% 20 mm
56.0% 10 mm
44.0% sand
100.0%
Blended
Combined
Grading
SUM
44.0%
100.0%
0.8%
1.4%
0.0%
TO
4.0%
1.3%
1.3%
0.0%
TO
8.0%
10.0%
TO
35.0%
35.0%
TO
55.0%
Qatar Sand
Specification
6.2%
6.7%
24.6%
25.8%
35.0%
36.4%
39.8%
41.5%
43.1%
51.9%
44.0%
99.2%
44.0%
100.0%
44.0%
100.0%
95.0%
TO
100.0%
44.0%
100.0%
100.0%
TO
100.0%
20.0
5.0
0.600
37.5
DATE
11/15/2006
200.0 kg
3.15
3
0.063 m
0.06
Admixture FLOWCABLE SG
1.31
Admixture FLOWCABLE
12.0 kg
Admixture volume
3
0.009 m
0.34
0.068 m
68.0 kg ( litres)
0.141 m3
1990.7 kg/m3
10:37 h:min
Ambient Temperature
31.0 oC
Water Temeperature
1.4 oC
Cement Temperature
22.9 oC
Admixture Temperature
23.8 oC
o
19.6 C
Flow @ 0 Minutes
15.31 seconds
Flow @ 30 Minutes
Average weight of 6 cubes
before soaking
18.00 seconds
245.00 grams
Date________________
Date________________
DATE
kg
Admixture volume
m3
Water volume
m3
Water weight
kg ( litres)
Volume of Grout
m3
Density of Grout
kg/m3
Time of Test
h:min
Ambient Temperature
Water Temeperature
Admixture Temperature
C
C
C
C
grams
Date________________
Date________________
22/07/07
MIX
PROPORTION
Percentage
same capacity
trucks
Laboratory Engineer
Backfill
Material
Gabbro
Material
Qatar Washed
Sand
50%
33%
17%
3 TRUCKS
2 TRUCKS
1 TRUCK
2/15/2007
1.OP Cement
OP Cement S.G.
Microsilica
Microsilica S.G.
340.000
3.150
0.000
2.350
kg
0.108
m3
0.400
Water volume
0.136
kg
m3
Glenium 110M
4.400
ltr
4.822
1.096
0.99%
0.003
m3
kg
0.005
m3
0.5%
8.000
Volume of Paste
0.252
m3
5. Volume of Aggregates
0.748
m3
20 mm
10 mm
Qatar sand
715.661
459.297
900.562
2075.520
kg
kg
kg
kg
2.917
0.647
0.36
%
%
5a. 20mm
S.G. SSD
water absorption
moisture content
uncorrected
volume
weight
0.258
752.340
5b. 10mm
S.G.SSD
water absorption
moisture content
2.924
0.886
1.52
m3
kg
%
%
32.8%
21.0%
46.2%
100.0%
uncorrected
volume
weight
0.166
483.996
2.606
1.458
6.400
m3
kg
%
%
uncorrected
volume
weight
0.325
845.781
m3
kg
VOLUME TOTALS
OP Cement + Microsilica
Water
Glenium 110M
Air Voids
20 mm Aggregate
10 mm Aggregate
Qatar Sand
uncorrected
0.108
0.136
0.003
0.005
0.258
0.166
0.325
corrected
0.108
0.157
0.003
0.005
0.251
0.161
0.315
3
1.000 m
1.000
Absorbed Water
20 mm Aggregate
10 mm Aggregate
Qatar Sand
4.868
4.288
12.331
kg
kg
kg
21.487
0.021
kg
m3
0.273
0.727
m3
m3
m3
m3
m3
m3
m3
m3
m3
WEIGHT TOTALS
OP Cement + Microsilica
Water
Glenium 110M
20 mm Aggregate
10 mm Aggregate
Qatar Sand
uncorrected
340.0
136.0
3.366
752.3
484.0
845.8
Moisture
Content
340.0
64.2
3.366
2.7
7.4
54.1
Moisture
corrected
340.0
93.3
3.366
755.0
491.4
899.9
TOTALS
W/C
2561.5
0.400
Glenium 110M
2583.0
0.99%
Date________________
Date________________
15/02/07
Used For:
20 mm Gabbro Moisture:
0.36 %
10 mm Gabbro Moisture:
1.52 %
Sand Moisture:
6.40 %
WEIGHT TOTALS
OPC + Microsilica
Mix Design
Absorbed
Moisture
BATCH
Weights
Water
Weights
WEIGHTS
340
340.0
136.0
Glenium 110M
3.4
20 mm Aggregate
752.3
4.9
2.7
755
10 mm Aggregate
484.0
4.3
7.4
491
Qatar Sand
845.8
12.3
54.1
900
TOTALS
2561.5
W/C
0.40
Laboratory Engineer
21.5
64.2
93
Water
0.99%
2583
BS 410
20mm Gabbro
10mm Gabbro
Qatar Sand
SIEVE SIZE
Individual
Blended
Individual
Blended
Individual
mm
100.0%
32.8%
100.0%
21.0%
100.0%
0.075
1.1%
0.4%
1.0%
0.2%
2.0%
0.150
1.1%
0.4%
1.0%
0.2%
3.2%
0.300
1.1%
0.4%
1.0%
0.2%
18.2%
0.600
1.1%
0.4%
1.5%
0.3%
59.0%
1.18
1.1%
0.4%
2.1%
0.4%
82.5%
2.36
1.1%
0.4%
2.5%
0.5%
91.1%
5.0
2.5%
0.8%
11.7%
2.5%
97.2%
10.0
8.1%
2.7%
98.2%
20.6%
100.0%
14.0
34.8%
11.4%
100.0%
21.0%
100.0%
20.0
93.1%
30.5%
100.0%
21.0%
100.0%
37.5
100.0%
32.8%
100.0%
21.0%
100.0%
100%
90%
80%
70%
60%
50%
40%
30%
0.600
20%
10%
0%
0.075 0.150
BS 410 Sieve Size, mm
32.8% 20 mm
21.0% 10 mm
46.2% sand
100.0%
Blended
Combined
Grading
SUM
46.2%
100.0%
0.9%
1.5%
0.0%
TO
4.0%
1.5%
2.0%
0.0%
TO
8.0%
10.0%
TO
35.0%
35.0%
TO
55.0%
Qatar Sand
8.4%
9.0%
27.3%
27.9%
38.1%
38.9%
42.1%
43.0%
44.9%
48.2%
46.2%
69.5%
46.2%
78.6%
Specification
46.2%
97.7%
95.0%
TO
100.0%
46.2%
100.0%
100.0%
TO
100.0%
20.0
5.0
0.600
37.5