(A2LA Cert. No. 2471.

01) 11/20/2012 Page 1 of 4










SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005


FIAREX TESTING LABORATORY INC.
2425 Industrial Blvd.
Chambly, Quebec J 3L 4W3, Canada
J ean-Pierre Rioux Phone: 514 651 6312
www.fiarex.com E-mail: info@fiarex.com

MECHANICAL

Valid To: September 30, 2014 Certificate Number: 2471.01

In recognition of the successful completion of the A2LA evaluation process, accreditation is granted to this
laboratory to perform the following tests:

Test Method(s): Test Name:

ASTM D3359 Tape Adhesion

MIL-STD-883
Method 1009
Method 1010
Method 2002 TC: A, B
Method 2005 TC: A, B
Method 2007 TC: A, B
Method 2026 TC: A to K


Salt Atmosphere (Corrosion)
Temperature Cycling
Mechanical Shock
Vibration Fatigue
Vibration, Variable Frequency
Random Vibration
MIL-STD-810E-F
Method 501
Method 502
Method 503
Method 507
Method 509
Method 514
Method 516


High Temp
Low Temp
Temperature Shock
Humidity
Salt Spray
Vibration (Random, Random on Random)
Shock
MIL-STD-202G
Method 101
Method 103
Method 107
Method 108
Method 201
Method 204 TC: A, B, C, D, F, G
Method 213 TC: A to K
Method 214


Salt Atmosphere (Corrosion)
Humidity (Steady State)
Thermal Shock (Air)
Life
Vibration
Vibration High Frequency
Shock (Specified Pulse)
Random Vibration



(A2LA Cert. No. 2471.01) 11/20/2012 Page 2 of 4

Test Method(s): Test Name:

International Electrotechnical Commission (IEC)
IEC 60068-2-1
IEC 60068-2-2
IEC 60068-2-3
IEC 60068-2-6
IEC 60068-2-11
IEC 60068-2-14 (Tests Na, Nb)
IEC 60068-2-27
IEC 60068-2-30
IEC 60068-2-31
IEC 60068-2-38
IEC 60068-2-52
IEC 60068-2-64
IEC 60068-2-75
IEC 60068-2-78
IEC 60255-21-1
IEC 60255-21-2
IEC 60529


IEC 61373


Environmental Testing Procedures Cold
Environmental Testing Procedures Dry Heat
Damp Heat Steady State
Sinusoidal Vibration
Salt Spray
Temperature Variation
Mechanical Shocks
Damp Heat Cyclic
Rough Handling Shocks (Free fall)
Humidity Cycling
Salt Mist Cyclic
Vibration, Broadband Random
Impact Hammer
Damp Heat Steady State
Sinusoidal Vibration
Mechanical Shock
Degrees of Protection Provided by Enclosures
(IPX3, IPX4, IPX5, IPX6, IPX7, IP2X, IP3X,
IP4X, IP5X, IP6X)
Vibration and Mechanical Shock
RTCA/DO-160E
Section 4
Section 4.5.1

Section 4.5.2
Section 4.5.3

Section 4.5.4
Section 4.6.1
Section 5
Section 6
Section 7
Section 8
Section 8.5.1
Section 8.5.2
Section 8.6
Section 8.7.1
Section 8.7.2
Section 11




Section 14


Temperature and Altitude
Ground Survival Low Temperature and Short-Time
Operating Low Temperature
Operating Low Temperature
Ground Survival High Temperature and Short-Time
Operating High Temperature
Operating High Temperature
Altitude
Temperature Variation
Humidity
Operational Shocks and Crash Safety
Vibration
Vibration
Vibration
Vibration
Vibration
Vibration
Fluid Susceptibility
- Hydraulic Fluids
- Lubricating Oils
- De-Icing Fluid
- Fire Extinguishants
Salt Spray

JEDEC
J ESD22-A100
J ESD22-A101
J ESD22-A103
J ESD22-A104
J ESD22-A105

Cycled Temperature Humidity Bias Life Test
Steady State Temperature Humidity Bias Life Test
High Temperature Storage Life
Temperature Cycling
Power Temperature Cycling
(A2LA Cert. No. 2471.01) 11/20/2012 Page 3 of 4

Test Method(s):

Test Name:
JEDEC (contd)
J ESD22-A119
J ESD22-B103
J ESD22-B104 (A to H)


Low Temperature Storage Life
Vibration Variable Frequency
Mechanical Shock
Telcordia GR-1221
Section 6.2.1
Section 6.2.2
Section 6.2.3
Section 6.2.4
Section 6.2.5
Section 6.2.6
Section 6.2.7
Section 6.2.8


Mechanical Shock
Vibration
Thermal Shock
High Temperature Storage
Damp Heat
Low Temperature Storage
Temperature Cycling
Cyclic Moisture Resistance
GM 3172
Section 9.3.1.1

Section 9.3.1.2

Section 9.3.1.3

Section 9.3.2
Section 9.3.3
Section 9.4.1
Section 9.4.2
Section 9.4.3
Section 9.4.5
Section 9.4.6
Section 9.4.7


Random Vibration Mounting Location Engine or
Transmission (without Thermal Cycling)
Random Vibration Mounting Location Sprung
Masses (without Thermal Cycling)
Random Vibration Mounting Location Unsprung
Masses (without Thermal Cycling)
Post Thermal Fatigue Vibration
Mechanical Shock Pothole
High Temperature Degradation
Thermal Shock Air-to-Air
Power Temperature Cycle
Humidity Heat Cyclic
Humid Heat Constant
Salt Mist

GM 15310
Section 3.2.1.1.1
Section 3.2.1.2
Section 3.2.1.3
Section 3.2.1.4
Section 3.2.1.5
Section 3.2.1.6
Section 3.2.1.7
Section 3.2.1.8
Section 3.2.1.9


Leak
Life Cycle Test/ Pressure (Creep)
Vibration
Pressure Cycle
Burst Strength at Ambient
Burst Strength at Elevated Temperature
Drop
High Temperature Soak
Low Temperature Soak
GM 15725
Section 4.3
Section 4.4

Section 4.5
Section 4.6
Section 4.7





Resistance to Temperature Humidity Cycle
Resistance of Material to Heat Ageing/ Oxidation
Stability
Resistance to Heat with Visual Evaluation
Impact Resistance
Resistance to Fluids
(A2LA Cert. No. 2471.01) 11/20/2012 Page 4 of 4

Test Method(s):

Test Name:
GM 16288
Section 3.2.1.1.2
Section 3.2.1.1.3
Section 3.2.1.1.4
Section 3.2.1.1.6
Section 3.2.1.1.7
Section 3.2.1.1.8
Section 3.2.1.2.1
Section 3.2.1.2.2
Section 3.2.1.2.3


Leak
High Temperature Soak
Low Temperature Soak
Burst Strength
Drop
Vacuum
Life Cycle
Pressure Cycle
Vibration
GM 6139M
Section 3.1
Section 3.2
Section 3.3
Section 3.9
Section 3.10
Section 3.12
Section 5.1


Humidity
Water Immersion
Neutral Salt Spray and Air Blow Off
Temperature Cycle
Tape Adhesion
Wear Resistance
Effect of Fluids
Chrysler PF-12032
Section 5.2
Section 5.3
Section 5.4
Section 5.6
Section 7.3
Section 7.4
Section 7.5


Vacuum Leak
Pressure Leak
High Pressure
Over Flow Tube Pull Off
Pressure Cycle
Constant Pressure and Temperature
Thermal Cycling
Chrysler PF-12184
Section 3.1
Section 3.3
Section 3.4
Section 3.5
Section 3.6
Section 4.3.1
Section 4.3.2
Section 4.3.3
Section 4.3.4
Section 5.11

Vibration
Freeze/ Thaw
Low Temperature Exposure
High Temperature Exposure
Humidity
System Strength
System Flow
System Washer Pressure
Cap Effort
Washer System Compliance Verification

Chrysler PF-11710
Section 3.2
Section 4.2
Section 4.3
Section 5.1
Section 5.3
Section 5.4
Section 5.5
Section 5.6
Section 5.7

Fluid Compatibility
Drop Impact
Foreign Object Impact Resistance
Grommet Retainer Side Loading
Cover Retention Room Temperature
Cover Retention High Temperature
Cover Retention Low Temperature
Multiple Cover Removal
Cover Installation














A2LA has accredited
FIAREX TESTING LABORATORY INC.
Chambly, Quebec, Canada
for technical competence in the field of
Mechanical Testing

This laboratory is accredited in accordance with the recognized International Standard ISO/IEC 17025:2005 General Requirements for
the Competence of Testing and Calibration Laboratories. This accreditation demonstrates technical competence for a defined scope and the
operation of a laboratory quality management system (refer to joint ISO-ILAC-IAF Communiqu dated 8 January 2009).

Presented this 20
th
day of November 2012.


_______________________
President & CEO
For the Accreditation Council
Certificate Number 2471.01
Valid to September 30, 2014





For the tests or types of tests to which this accreditation applies, please refer to the laboratorys Mechanical Scope of Accreditation.