The Power Supply unit 560PSR00 generates the two supply voltages ( 5 V DC and 24 V DC ) for the RTU560 subracks 23ET24, 23TP22, 560MPR03 and 560SFR02. It is possible to configure redundant power supplies for project configurations with higher requirements to availability.
The Power Supply unit 560PSR00 generates the two supply voltages ( 5 V DC and 24 V DC ) for the RTU560 subracks 23ET24, 23TP22, 560MPR03 and 560SFR02. It is possible to configure redundant power supplies for project configurations with higher requirements to availability.
The Power Supply unit 560PSR00 generates the two supply voltages ( 5 V DC and 24 V DC ) for the RTU560 subracks 23ET24, 23TP22, 560MPR03 and 560SFR02. It is possible to configure redundant power supplies for project configurations with higher requirements to availability.
Doc.-No.: 1KGT 150 784 V001 1 1 Power Supply 560PSR00
Application The power supply unit 560PSR00 generates the two supply voltages ( 5 V DC and 24 V DC ) for the RTU560 subracks 23ET24, 23TP22, 560MPR03 and 560SFR02. The output power is sufficient to supply a subrack with up to 4 com- munication units. It is possible to configure redundant power sup- plies for project configurations with higher re- quirements to availability. In this configuration two power supply units 560PSR00 are operating in parallel mode. They are able to take over the load, if one power supply fails. Only power supplies of the same type and rubric should be used for red. operation. The power supply unit 560PSR00 is available in one version (rubric). R0001: Input Range 24 ... 60 V DC
Characteristics The power supply unit 560PSR00 has the follow- ing characteristics and functions: Potential isolation between the input and the outputs Cooling by natural convection Electronic power limitation Short-circuit proof Over-voltage protection Controlled load balancing 2 light emitting diodes for displaying out- put voltage U1 and U2 Parallel operation with monitoring of re- dundant power supply configuration Alarm indication (relay) in case of failure Reverse Voltage protection
Figure 1: Function block diagram 560PSR00 RTU560 Data Sheet Power Supply 560PSR00
Doc.-No.: 1KGT 150 784 V001 1 2 Technical Data In addition to the RTU560 general technical data, the following applies:
Input R0001 24 to 60 V DC nominal 19,2 69 V DC (-20 +15 %) Voltage Interruption 50 ms; 0 % U N (U N 48V) Starting Current: 10 A according IEC 60870-4 Efficiency: 85 % External circuit- breaker The plus lead needs a cir- cuit-breaker upstream with 10A trip current. Output Output Power 44.3 W total De-rating -2,5 % per Kelvin 55 Grad C Output U1 Voltage: 5,0 V DC Tolerance: 5,0 ... 5,3 V DC Current min.: 0.2 A Current max.: 5.5 A Residual Ripple 30 mV ss
Output U2 Voltage: 24 V DC Tolerance: 22,4 ... 26,3 V DC Current min.: 0 A Current max.: 0,7 A Residual Ripple 80 mV ss
Mechanical Layout PCB dimension 3HE, Euro-Card format (160 x 100 mm) Front panel 8R, 2 Slots (40 mm) Weight Ca. 0,6 kg Connection Type Connector Indirect, 48-pole Type F DIN 41612 Supply connection Indirect, 3-pole, COMBICON terminal connec- tion GMSTB 2,5/3-ST-7,62 or GMVSTBR 2,5/3-ST-7,62
Electromagnetic Compatibility EN61000-4-2 Electrostatic Discharge Immunity 8KV Air 6KV direct Performance criteria A EN61000-4-3 Radiated RF Field 10V/m Performance criteria A EN61000-4-1 Fast Transient Immunity (Burst) 1KV/2KV Performance criteria A EN61000-4-5 Surge Immunity 2KV Performance criteria A EN61000-4-6 Conducted RF Field 10V Performance criteria A EN55011 RF emmisions air 30MHz up to 1GHz class B (Industry) EN55011 RF emmisions cable 0,01 MHz up to 30 MHz class B (Industry) EN61000-4-16
300 V / 0,6 A 30 V / 6 A EN61000-4-17 12,5% AC simple EN61000-4-18 2 KV DC PE 1KV DC+ / DC-
Environmental Compatibility EN60068 -2 Continuous Test 70C 96h fully active loaded EN60068-2-1 Continuous Test -25C 96h fully active loaded EN60068-2- 1 Start up Test -40C System starts on -40C EN60068-2-14 Continuous Test 0C /70C Temperature cycles 48h , fully active loaded EN60068-2-30 Continuous Test 55C/95% rel. Humidity Storage, not activ IEC60255-21-3 Seismic Test Class 1 IEC60255-21-1 Vibration Test Class 1 RTU560 Data Sheet Power Supply 560PSR00
Doc.-No.: 1KGT 150 784 V001 1 3 IEC60870-2-2 Vibration durance test Class Bm IEC60255-21-2 Schock Test 15g, Class 1 IEC60870-2-1 Schock Test 25g, Class 1 IEC60255-21-2 Bump Test 10g, Class 1 Electrical Safety EN60950- 1 Safety class 1 Electrical Safety investiga- tion Flamability investigation Environmental Conditions Temperatur -40 C start up -25 C +70 C operation -40 C +85 C storage
Relative humidity 5 95 % (non condensing)
Ordering Information 560PSR00 R0001 1KGT 026 500 R0001
RTU560
Data Sheet Power Supply 560PSR00 Doc.-No.: 1KGT 150 784 V001 1 4
Ethernet
Note: We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB AG does not accept any re- sponsibility whatsoever for potential errors or possible lack of infor- mation in this document.