Bulletin 7669647 Revision B Page 1 of 2

Andrew Institute offers installation training.


Connector Attachment
For Braided Cable CNT-300, CNT-400
N & TNC Male, Right Angle, Captivated Pin, Clamp-type Body
6.
5.
7.
2.
Straighten first 200.0 mm (7.874") min.
of the cable.
1.
Tools Connector: 300BPTR-C, 400BPTR-C
300BPNR-C, 400BPNR-C
4.
3.
Remove 6.5 mm (0.256") of Jacket only.
Safety
Knife
Wire
Brush
File Forfex
200 mm (7.874) min.
Torque
Wrench
Wrench
15 mm
15 mm
16 mm
6.5 0.5 mm
(0.256 0.020")
Comb braid straight with wire brush;
Fold back braid as shown.
Fold back braid around part A and comb braid as shown,
the braid should be straight and equally spaced after comb.
Cut off the redundant braid as shown.
Taper braid towards center conductor as shown;
According to illustration below to push and rotate slightly part A onto cable without
damaging the braid.
Remove 5.0 mm (0.197") of foil & foam,
exposing the center conductor.
Remove all foam/glue residue from the
center conductor.
Don't damage center conductor
5.0 0.5 mm
(0.197 0.020")
Clear all residual braid wire
Connector Body
Cable Attachment
A
16 mm
I
n
c
h
e
s

2
3
4
1
M
i
l
l
i
m
e
t
e
r
s
2
0
3
0
4
0
5
0
6
0
7
0
8
0
9
0
1
0
0
Notice: Andrew LLC disclaims any liability or responsibility for the results of improper or unsafe installation, inspection, maintenance, or removal practices.
Aviso: Andrews LLC no acepta ninguna obligacin ni responsabilidad como resultado de prcticas incorrectas o peligrosas de instalacin, inspeccin, mantenimiento o retiro.
Avis : Andrew LLC dcline toute responsabilit pour les consquences de procdures dinstallation, dinspection, dentretien ou de retrait incorrectes ou dangereuses.
Hinweis: Andrew LLC lehnt jede Haftung oder Verantwortung fr Schden ab, die aufgrund unsachgemer Installation, berprfung, Wartung oder Demontage auftreten.
Ateno: A Andrew LLC abdica do direito de toda responsabilidade pelos resultados de prticas inadequadas e sem segurana de instalao, inspeo, manuteno ou remoo.
Avvertenza: Andrew LLC declina eventuali responsabilit derivanti dellesecuzione di procedure di installazione, ispezione, manutenzione e smontaggio improprie o poco sicure.
www.commscope.com
Visit our Web site at www.commscope.com or contact your local Andrew LLC representative for more information.
2012 CommScope, Inc. All rights reserved.
Andrew LLC is a trademark of CommScope. All trademarks identied by or
TM
are registered trademarks or trademarks,
respectively, of CommScope. This document is for planning purposes only and is not intended to modify or supplement any
specications or warranties relating to Andrew LLC products or services.
Andrew LLC
Customer Service 24 hours
U.S.A., Canada, Mexico: +1-800-255-1479
U.K.: 0800 250055 Brazil: +55-15-2102-4000
Other Europe: +44 592 782 612
Bulletin 7669647 Revision B Page 2 of 2
8.
10.
Coupling torque.
11.
50
O O O O O
(Part Name)
(Connector)


(Pb) (Hg)
(Cr6+) (Cd) (PBB) (PBDE)
X
o: SJ/T 11363-2006.
X: SJ/T 11363-2006.
The cable attachment must be straight and aligned with the
hole of connector inner contact; Push prepared cable attachment
into the connector body until stopped; The cable center conductor
must be inserted into the connector inner contact fingers.
Tighten the connection to the torque value of
6.8-9.0 Nm (60-80 lb-in).
Note:Do not turn connector body, turn clamp nut.
Chamfer the center conductor at a 45angle.
9.
Burrs
45
Insert into hole
Hold connector by hand
Hold cable by hand
6.8-9.0 Nm
(60-80 Ib-in)
TNC type
(4.1-6.1 lb-in)
0.46-0.69 Nm
N type
(6.2-9.7 lb-in)
0.7-1.1 Nm
Wrench flat 15 mm for 300BPNR-C,
400BPNR-C, 400BPTR-C.
Wrench flat 16 mm for 300BPTR-C.
Torque wrench flat 15 mm for
300BPNR-C, 300BPTR-C.
Torque wrench flat 16 mm for
400BPNR-C, 400BPTR-C.