Configuration of Water Valve is a trademark of Kimray, Inc.

www.kimray.com
S
E
C
T
I
O
N

D

Table of Contents Next > Section Contents


NOTE: We reserve the right to modify or change, without prior
notice, any statement or information contained herein. If exact dimen-
sions or specifications are required by the customer
certified prints will be furnished for a minimum charge upon request
to KIMRAY, Inc.
Copyright 1992, KIMRAY, Inc.
< Previous Table of Contents Next > Section Contents
www.kimray.com
D:i
Issued 10/09
OIL AND WATER VALVES
TREATER VALVE
DUCTILE IRON
Current Revision:
APPLICATION:
As oil or water valve for emulsion treaters, water
knockouts and gunbarrels. Can be used for pressure,
atmospheric, or vacuum operation. Ideal for discharging
salt water to disposal systems.
Operating Description Parts
Material Pressure of Operation List
Cast Iron 2"-125 psig Max. Pg. 10.1 Pg. 10.3
Cast Iron 3",4",6"-60 psig Max. Pg. 10.1 Pg. 10.3
Ductile 125 psig Max. Pg. 10.1 Pg. 10.4
Steel 125 psig Max. Pg. 10.1 Pg. 10.5
TREATER VALVE
APPLICATION:
Diaphragm motor for Mechanical Dump Valve
Operating Parts
Material Pressure List
Cast Iron 125 psig Max. Pg. 20.1
DIAPHRAGM MOTOR VALVE
2" & 3" Pg. 10.6
REMOVABLE HARD SEAT ASSEMBLY
Treater Valves 10.2
Diaphragm Motor Valve 20.2
DIMENSIONS & INSTALLATIONS
< Previous Table of Contents Next > Section Contents
www.kimray.com
OIL AND WATER VALVES
ELASTOMERS
D:ii
Issued 9/12
Current Revision:
Change material names
TEMPERATURE:
-10 to +350 F
-23 to +177 C
APPLICATION:
Crude Oil & Gas Production, Glycol Dehydratbrs,
Gasoline, Jet Fuel & Diesel Fuel Pumping, Water Disposal,
Methanol Injection Pumps. (Also Vacuum Service) (Gas
permeability is very low)
FLUID / GAS:
Crude Oil & Gas, Sour Gas (C02), Propane, Gasoline,
Diesel, Fuel Oil Systems
DO NOT USE WITH:
Hot Water, Not preferred for wet H2S, Methyl Alcohol,
Amines, Sodium hydroxide solutions
TEMPERATURE:
-65 to +300 F
-54 to +148 C
APPLICATION:
Steam Flood
FLUID / GAS:
Steam, Water, Alcohol
DO NOT USE WITH:
Crude Oil & Gas, Diester Lubricants (Lube Oils)
TEMPERATURE:
-40 to +220 F
-40 to +104 C
APPLICATION:
High abrasion resistance Seats, Diaphragms
FLUID / GAS:
Crude Oil gas and Water, Sour Gas (C02), propane,
butane, fuel, mineral oil and grease
TEMPERATURE:
0 to +300 F
-17 to +149 C
APPLICATION:
Production Heaters, Thermostats
FLUID / GAS:
Crude Oil & Gas at High Temperature
DO NOT USE WITH:
Alcohol, Glycols
TEMPERATURE:
+30 to +500 F
0 to +260 C
APPLICATION:
Crude Oil & Gas Production (High heat), Steam
Flood Production Chemicals (corrosion inhibitors) Amine
Sweetener Systems, Gasoline, Diesel, Fuel Oil Systems
FLUID / GAS:
Crude Oil & Gas Production, H2S, Steam, Petroleum
fluids, Sea Water
TEMPERATURE:
-15 to +300 F
-26 to +149 C
APPLICATION:
Crude Oil & Gas Production w/ H2S C02
FLUID / GAS:
Crude Oil & Gas H2S, C02, Sea Water
TEMPERATURE:
Buna-N:
-40 to +220 F
-40 to +105 C
Low-Temp:
-85 to +120 F
-65 to +49 C
APPLICATION:
Crude Oil & Gas Production Glycol Dehydrators,
Gasoline, Jet Fuel & Diesel Fuel Pumping, Water Disposal,
Methanol Injection Pumps, Water pump seals, hydraulic
pump seals
FLUID / GAS:
Crude Oil & Gas, Good to Poor in Sour Production (See
HSN), Water, Glycols, Hydraulic Oils, Resistance to crude
oil in the presence of hydrogen sulfide and amines, Diesel
fuel, fuel oils
DO NOT USE WITH:
Aromatic hydrocarbons, chlorinated hydrocarbons,
phosphate esters (hydraulic fluids)
TEMPERATURE:
-40 to +400 F
-20 to +204 C
APPLICATION:
Chemically Inert Elastomer Best in static Do not use at
low temps
FLUID / GAS:
Almost All Chemicals
AFLAS

is a trade mark of Asahi Glass Co VITON

is a trade mark of Dupont


EP (EPDM)
POLYURETHANE (P)
TEFLON (T)
POLYACRYLATE (H)
HSN (HNBR)
NITRILE
< Previous Table of Contents Next > Section Contents
Current Revision:
www.kimray.com

Configuration of Water Valve is a trademark of Kimray, Inc. D:10.1


Issued 3/06
OIL AND WATER VALVES
TREATER VALVE
APPLICATIONS:
As oil or water valve for emulsion treaters, water knockouts
and gunbarrels. Can be used for pressure, atmospheric, or
vacuum operation. Ideal for discharging salt water to disposal
systems.
FEATURES:
Single soft seat for tight shut off
Balanced against upstream pressure
Balanced against downstream pressure or vacuum
Standard weight and lever holds approx. 4 liquid head
Weights may be added to increase liquid head
Can be manually opened and closed
Sample tap on inlet connection
Rotary stuffing box with leakless, low friction TEFLON pack-
ing
All interior parts can be removed without taking valve out of
line
Prevents air from entering salt water disposal system piping

OPERATION:
The inlet of the valve is connected to the water siphon leg
or oil discharge line from an emulsion treater or water knock-
out. Vessel Gas Pressure (Red) is connected to the UPPER
HOUSING to balance the Gas Pressure under the MAIN
DIAPHRAGM.
The effective area of the BALANCING DIAPHRAGM is the
same as the effective area of the SEAT. Pressure or vacuum
acting on either side of the BALANCING DIAPHRAGM will can-
cel the pressure or vacuum acting on the SEAT. This balancing
feature prevents the slamming open and closed prevalent in
unbalanced single seat construction.
The Vessel Gas Pressure (Red) with the UPPER HOUSING
acts upwardly on the BALANCING DIAPHRAGM to cancel the
downward pressure on the single SEAT. Downstream Pressure
Vacuum (Blue) acting on the SEAT is communicated to the top
side of BALANCING DIAPHRAGM. This cancels any down-
stream pressure or vacuum effect on the valve operation.
The force to hold the SEAT closed is applied by a WEIGHT
and LEVER through a rotary TEFLON packed stuffing box to a
PIVOT STEM which pushes down on the Diaphragm Assembly.
When the liquid rises in the discharge piping of the vessel
above the set level, it lifts the Diaphragm Assembly against the
WEIGHT load to open the valve. As liquid is discharged to lower
the level, the WEIGHT closes the valve.
Liquid level may be adjusted up to approximately four feet by
moving the WEIGHT on the LEVER. Additional weights may be
added if a higher level is desired.
< Previous Table of Contents Next > Section Contents
Current Revision:
www.kimray.com

Configuration of Water Valve is a trademark of Kimray, Inc. D:10.2


Issued 3/06
OIL AND WATER VALVES
TREATER VALVE
INSTALLATION AND DIMENSIONS
INSTALLATION DIMENSIONS
26 SWA 9
3
/8 4
7
/8 3
1
/2 10
5
/8 8
1
/2
27 FWA-D 9
3
/8 6
1
/2 3
1
/2 10
5
/8 8
1
/2
27 FWA-S 9
3
/8 6
3
/8 3
1
/2 10
5
/8 8
1
/2
36 FWA 11
3
/4 8 4
1
/4 13
1
/2 13
37 FWA-D 11
3
/4 8 4
1
/4 13
1
/2 13
46 FWA 13 9 4
3
/4 14
5
/8 13
47 FWA-D 13 9 4
3
/4 14
5
/8 13
47 FWA-S 13 9 4
3
/4 14
5
/8 13
66 FWA 18
5
/8 12
1
/4 6
3
/4 21
1
/2 12
1
/2
DIMENSIONS - INCHES
Valve No. A B C D E
NOTE: Do not connect gas equalizing line to gas vent
line, burner manifold, or downstream of mist extractor.
1 1,250 3,200 5,950 12,750
2 1,800 4,500 8,450 18,000
3 2,200 5,500 10,300 22,000
4 2,500 6,400 11,900 25,500
5 2,800 7,350 13,300 27,500
10 4,000 10,100 18,900 40,500
15 4,900 12,400 23,100 49,500
20 5,700 14,300 26,800 57,000
30 6,950 17,600 32,800 81,000
50 8,900 22,600 42,200 90,500
60 9,850 24,800 46,200 99,000
75 11,900 56,000
For gravity correction multiply values obtained from chart by
. Where G is specific gravity of flowing liquid.
G
1
CAPACITY - Bbls. Water/ Day, Steady Flow
2 3 4 6
Valve Size - Inches
Press.
Drop
Across
Valve
< Previous Table of Contents Next > Section Contents

Configuration of Water Valve is a trademark of Kimray, Inc.


www.kimray.com
D:10.3
Issued 11/11
OIL AND WATER VALVES
TREATER VALVE
CAST IRON
ANGLE VALVES AVAILABLE: NOTES:
CAT. SIZE MAX
NO. TYPE VALVE W.P. KIT
DAA 2" SCRD. 26 SWA 125 REL
DAC 3" FLGD.** 36 FWA 60 REM
DAD 4" FLGD.** 46 FWA 60 REN
DAE 6" FLGD.** 66 FWA 60 REP
**Companion flanges, nuts, bolts and gaskets are furnished, at extra cost only when
specified.
*These are recommended spare parts and are stocked as
repair kits.
Lever Bars for higher liquid head are available 419L and
420L.

Current Revision:
Change 2 Pin number
< Previous Table of Contents Next > Section Contents

Configuration of Water Valve is a trademark of Kimray, Inc.


www.kimray.com
D:10.4
Issued 7/11
OIL AND WATER VALVES
TREATER VALVE
DUCTILE IRON
ANGLE VALVES AVAILABLE: NOTES:
CAT. SIZE MAX
NO. TYPE VALVE W.P. KIT
DAB 2" FLGD.** 27 FWA-D 125 REL
DAG 3" FLGD.** 37 FWA-D 125 REM
DAH 4" FLGD.** 47 FWA-D 125 REN
**
Companion flanges, nuts, bolts and gaskets are furnished, at extra cost, only when
specified.
*These parts are recommended spare parts and are stocked
as repair kits.
Lever Bars for higher liquid head are available 419L and
420L.

Current Revision:
Change 2 Pin number
< Previous Table of Contents Next > Section Contents

Configuration of Water Valve is a trademark of Kimray, Inc.


www.kimray.com
D:10.5
Issued 7/11
OIL AND WATER VALVES
TREATER VALVE
STEEL
ANGLE VALVES AVAILABLE: NOTES:
CAT. SIZE MAX
NO. TYPE VALVE W.P. KIT
DAI 2" FLGD.** 27 FWA-S 125 REL
DAJ 3" FLGD.** 37 FWA-S 125 REM
DAF 4 FLGD.** 47 FWA-S 125 REN
**
Companion flanges, nuts, bolts and gaskets are furnished, at extra cost, only when
specified.
*These are recommended spare parts and are stocked as
repair kits.

Current Revision:
Change 2 Pin number
< Previous Table of Contents Next > Section Contents
Current Revision:
www.kimray.com
D:10.6
Issued 3/06
OIL AND WATER VALVES
REMOVABLE HARD SET ASSEMBLY
SEATS AVAILABLE:
Retainer
Hardened Removable Seat
Gasket
2" 384HA 384HB 387
3" 385PH 385HB 388
3" 385ASS6 385HB 388
SEAT RETAINER GASKET
LINE
SIZE
< Previous Table of Contents Next > Section Contents
www.kimray.com
Current Revision:
Change 2 Packing Ring quantity
D:20.1
Issued 3/10
OIL AND WATER VALVES
DIAPHRAGM MOTOR VALVE
CAST IRON
VALVES AVAILABLE: NOTES:
CAT. SIZE MAX
NO. TYPE VALVE W.P. KIT
DMA 2" SCRD. 26 DM 125 REW
*These are recommended spare parts and are stocked as
repair kits.
< Previous Table of Contents Next > Section Contents
Current Revision:
www.kimray.com

Configuration of Mechanical Oil Valve ia a trademark of Kimray, Inc. D:20.2


Issued 2/09
OIL AND WATER VALVES
DIAPHRAGM MOTOR VALVE
INSTALLATIONS
USED AS DIAPHRAGM MOTOR FOR
MECHANICAL DUMP VALVE. LIQUID HEAD
AGAINST 26 DM DIAPHRAGM, ASSISTED
BY 7 psig WEIGHT, MOVES LEVER WHICH
OPENS DUMP VALVE. REFER TO SECTION
CP FOR MECHANICAL DUMP VALVE
OPERATION AND PARTS REFERENCE
DRAWINGS.
NOTE: ADJUSTING BLOCKS
SHOULD BE MOVED TO
ADJUST FOR SPREAD.
WEIGHT IS POSITIONED FOR
MAXIMUM HEIGHT.
TYPICAL DIAPHRAGM MOTOR VALVE INSTALLATIONS