You are on page 1of 2

Intra-frequency measurement reporting criteria.

The triggering of the event-triggered reporting for an intra-frequency measurement. All


events concerning intra-frequency measurements are labelled 1x where x is a, b, c.
1) Event 1a:
A Primary CPICH enters the Reporting Range.
2) Event 1b:
A Primary CPICH leaves the Reporting Range.
3) Event 1c:
A Non-active Primary CPICH becomes better than an active Primary CPICH.
4) Event 1d:
Change of best cell.
5) Event 1e:
A Primary CPICH becomes better than an absolute threshold.
6) Event 1f:
A Primary CPICH becomes worse than an absolute threshold.

Inter-frequency measurement reporting criteria.

The triggering of the event-triggered reporting for an inter-frequency measurements. All
events concerning inter-frequency measurements are labelled 2x where x is a,b,c..
1) Event 2a:
Change of best frequency.
2) Event 2b:
The estimated quality of the currently used frequency is below a certain threshold and the
estimated quality of a non-used frequency is above a certain threshold.
3) Event 2c:
The estimated quality of a non-used frequency is above a certain threshold
4) Event 2d:
The estimated quality of the currently used frequency is below a certain threshold
5) Event 2e:
The estimated quality of a non-used frequency is below a certain threshold
6) Event 2f:
The estimated quality of the currently used frequency is above a certain threshold

Inter-system measurement reporting criteria.

The triggering of the event-triggered reporting for an inter-system measurement. All events
concerning inter-system measurements are labelled 3x where x is a,b,c..
1) Event 3a:
The estimated quality of the currently used UTRAN frequency is below a certain threshold
and the estimated quality of the other system is above a certain threshold.
2) Event 3b:
The estimated quality of other system is below a certain threshold
3) Event 3c:
The estimated quality of other system is above a certain threshold
4) Event 3d:
Change of best cell in other system

Traffic volume measurement reporting criteria.

Contains the measurement reporting criteria information for a traffic volume measurement.
1) Event 4a:
RLC buffer payload exceeds an absolute threshold.
2) Event 4b:
RLC buffer payload becomes smaller than an absolute threshold.

UE internal measurement reporting criteria.

The triggering of the event-triggered reporting for a UE internal measurement. All events
concerning UEinternal measurements are labelled 6x where x is a, b, c. In TDD, the events
6a - 6d are measured andreported on timeslot basis.
1) Event 6a:
The UE Transmitted Power becomes larger than an absolute threshold
2) Event 6b:
The UE Transmitted Power becomes less than an absolute threshold
3) Event 6c:
The UE Transmitted Power reaches its minimum value
4) Event 6d:
The UE Transmitted Power reaches its maximum value
5) Event 6e:
The UE RSSI reaches the UEs dynamic receiver range
6) Event 6f:
The UE Rx-Tx time difference for a RL included in the active set becomes larger than
anabsolute threshold
7) Event 6g:
The UE Rx-Tx time difference for a RL included in the active set becomes less than an
absolute threshold.