You are on page 1of 11

Quick Connectors Incorporated ( ) QCI is a leading provider of wellhead and

packer penetrator systems for use with electrical submersible pumps (ESP). is proud of
delivering quality, on-time products that meet our customers' requirements. We have over 20 years of
oil field experience installing our systems worldwide with a track record of excellence and reliability.
electrical penetrator systems eliminate the need for cable splicing, saving hours of costlyrig time,
andincreasingreliabilitybyreducingexposure toreactive agents.
offers various types of wellhead penetrator systems designed to work with a variety of
applications to meet customer requirements and needs. wellhead penetrator systems can be
designed to fit new or existing wellheads (concentric or non-concentric applications), or to
accommodate wellhead applications that were not originally designed for use with ESP applications.
wellhead penetrators can be easily retrofitted to replace existing competitor type mandrel
penetrator systems.
also offers specialty penetrator systems for applications requiring the use of BOPCans, ESP
Packers, dual or triple completions, and heater applications. These applications can also be retrofitted
toreplace existingcompetitor systems.
All of the penetrator systems are suitable for 375F/ 190C, and can be fitted to all ESPpump
cables andelectrical requirements currentlyinuse (up to 5000Volts and 257Amps).
operates under the ISO 9001-2000 requirements. All of the wellhead penetrator
systems are third party approved by Factory Mutual (FM) and CSA. The products are designed to
meet the highest classifications for safety compliance within the United States for operation of
electrical equipment inhazardous/explosive locations (Class I, Divisions 1&2).
We pride ourselves on quick delivery and excellent engineering support. provides on-site
installation (domestic and international) and can provide technical support through highly trained
international representatives. Complete in-house training simulating wellhead and packer penetrator
installation can be provided for customers who wish to install equipment. Training videos and
installationprocedures are available uponrequest.
QCI
QCI
QCI
QCI
QCI
QCI
QCI
QCI QCI
QCI
QCI
QCI
CI Unique Adaptable Global
Q
C
I
-
A
b
o
u
t
U
s
1
P
3
0
0
0
-
2
Specifications Features/Benefits
P3000-2
Wellhead Penetrator System
Boll Weevil Type
2
Cable Gland
Surface Power Cable (CLX)
P3000-2 Mini Mandrel
Canned Pump Coupling (CPC)
Surface Conduit System
Breather Vent/Detonation
Arrestor

FM & CSAApproved
Voltage: Dependant on Max. Rating of ESP Cable
Amperage: Dependant on Max. Rating of ESP Cable
Pressure: 5,000 psi API WP (13,500
Temp: 375 F, 190
Hazardous Area: Class I, Divisions 1 & 2 Group D
C

Eliminates cable splices in the wellbore.


Designed to eliminate large mandrel type penetrators.
Available as a P3000-2F for flat cable.
ESP cable is stripped and the three cable wires are
separated and sealed off with an elastomer sealing
element.
Reusable surface conduit system suitable for hazardous
locations.
UL listed surface cable (CLX) is terminated and sealed
in the conduit system for required length to reach the
power supply.
Permits the use of shielded and non-shielded cable.
psi Proof Test)
Cable Gland
Surface Power Cable (CLX)
P3000-2 Mini Mandrel
Canned Pump Coupling (CPC)
Surface Conduit System
Breather Vent/Detonation
Arrestor
Features/Benefits Specifications

FM & CSAApproved
Voltage: Dependant on Max. Rating of ESP Cable
Amperage: Dependant on Max. Rating of ESP Cable
Pressure:
Temp: 375 F, 190 C
Hazardous Area: Class I, Divisions 1 & 2 Group D
P3000-2F Wellhead Penetrator
System Seal Sub Type
3
P
3
0
0
0
-
2
F
Flat-to-Round Transition Collar
P3000-2 Mini Mandrel
Canned Pump Coupling (CPC)
Surface Conduit System
Breather Vent/Detonation
Arrestor
Cable Gland
Surface Power Cable (CLX)

Eliminates cable splices in the wellbore.


Designed to eliminate large mandrel type penetrators.
Available as a P3000-2 for round cable.
ESP cable is stripped and the three cable wires are
separated and sealed off with an elastomer sealing
element.
Reusable surface conduit system suitable for
hazardous locations.
UL listed surface cable (CLX) is terminated and
sealed in the conduit system for required length to
reach the power supply.
Permits the use of shielded and non-shielded cable.
5,000 psi API WP (13,500 psi Proof Test)
Specifications Features/Benefits
P3000-2DM
Wellhead Penetrator System
Canned Pump Coupling (CPC)
Surface Conduit System
Breather Vent/Detonation
Arrestor
Cable Gland
Surface Power Cable (CLX)
Upper Pigtail (Competitor)
Mandrel (Competitor)
Lower Pigtail (Competitor)
CI Dummy Mandrel
(Replaces items 1-3)
P3000-2 Mini Mandrel
Q
P
3
0
0
0
-
2
D
M

FM & CSAApproved
Voltage: Dependant on Max. Rating of ESP Cable
Amperage: Dependant on Max. Rating of ESP Cable
Pressure: 5,000 psi API WP (13,500
Temp: 375 F, 190 C
Hazardous Area: Class I, Divisions 1 & 2 Group D
4

Eliminates cable splices in the wellbore.


Available as a P3000-2FDM for flat cable.
ESP cable is stripped and the three cable wires are
separated and sealed off with an elastomer sealing
element.
AQCI dummy mandrel is provided to fit the existing
wellhead, replacing the competitors mandrel.
Reusable surface conduit system suitable for hazardous
locations.
UL listed surface cable (CLX) is terminated and sealed
in the conduit system for required length to reach the
power supply.
Permits the use of shielded and non-shielded cable.
psi Proof Test)
Features/Benefits Specifications
P3000-1
Wellhead Penetrator System
)
P
3
0
0
0
-
1
F
R
5
Surface Splice Boot
Ground Wire Connector
Breather Vent/Detonation
Arrestor
Cable Gland
Surface Power Cable (CLX)
Flat-to-Round Transition
Collar
Feed-thru Assembly
Bottom Seal Fittings
Canned Pump Coupling (CPC)
Bracket Assembly
Surface Conduit System

FM & CSAApproved
Voltage: Dependant on Max. Rating of ESP Cable
Amperage: Dependant on Max. Rating of ESP Cable
Pressure: 3,000 psi API WP (6,000 psi Proof Test)
Temp: 375 F, 190 C
Hazardous Area: Class I, Divisions 1 & 2 Group D

Eliminates cable splices in the wellbore.


Adaptable with either concentric or eccentric
wellhead completions, and can be run in small
annular spaced wells.
Three flexible fittings with Swagelok connections
seal off the penetrator above and below the tubing
hanger.
ESP cable is stripped and the three cable wires are
separated and sealed off with an elastomer sealing
element.
Reusable surface conduit system suitable for
hazardous locations.
UL listed surface cable (CLX) is terminated and
sealed in the conduit system for a required length
to reach the power supply.
Permits the use of shielded and non-shielded cable.
P
3
0
0
0
-
1
Specifications Features/Benefits
P5000 - Model 1
Wellhead Penetrator System

FM & CSAApproved
Voltage: 5000 VAC, 3 Phase
Amperage:
Pressure: 5,000 psi API WP (13,500 psi Proof Test)
Temp:
Hazardous Area: Class I, Divisions 1 & 2 Group D
150 Amp and 190 Amp versions available
375 F, 190 C
6
P
5
0
0
0
M
o
d
e
l
1
Triskelion
Male & Female Connectors
Bottom Seal Fittings
Bracket Assembly
Canned Pump Coupling (CPC)
Surface Conduit System
Breather Vent/Detonation
Arrestor
Cable Gland
Surface Power Cable (CLX)

Eliminates cable splices in the wellbore.


Adaptable for concentric wellhead completions,
and can be installed in small annular spaced wells.
Three flexible fittings with Swagelok connections
seal off the penetrator above and below the tubing
hanger.
Reusable surface conduit system suitable for
hazardous locations.
UL listed surface cable (CLX) is terminated and
sealed in the conduit system for required length to
reach the motor control panel.
Permits the use of shielded and non-shielded cable.
P
5
0
0
0
-
D
u
a
l
E
S
P

FM & CSAApproved
Voltage: 5000 VAC, 3 Phase
Amperage:
Pressure: 5,000 psi API WP (13,500 psi Proof Test)
Temp:
Hazardous Area: Class I, Divisions 1 & 2 Group D
150 Amp and 190 Amp versions available
375 F, 190 C
Features/Benefits Specifications
P5000 Dual ESP
Wellhead Penetrator System
Triskelion
Male & Female Connectors
Bottom Seal Fittings
Bracket Assembly
Canned Pump Coupling (CPC)
Surface Conduit System
7
Breather Vent/Detonation
Arrestor
Cable Gland
Surface Power Cable (CLX)

Eliminates cable splices in the wellbore.


Adaptable for concentric wellhead completions,
and can be installed in small annular spaced wells.
Three flexible fittings with Swagelok connections
seal off the penetrator above and below the tubing
hanger.
Reusable surface conduit system suitable for
hazardous locations.
UL listed surface cable (CLX) is terminated and
sealed in the conduit system for required length to
reach the motor control panel.
Permits the use of shielded and non-shielded
cables.

No splices above and below the packer.


Amainfold bushing is provided for dual string packers, and
can accommodate extra ports for control lines, if necessary.
For small diameter and multiple port packers, the
penetrators pass through 3 individual ports through the
packer.
Features/Specifications
P
a
c
k
e
r
P
e
n
e
t
r
a
t
o
r
S
y
s
t
e
m
s
8

Voltage: 5000 VAC, 3 Phase


Amperage: 150 Amp and 257 Amp versions available
Pressure: 5,000 psi API WP (10,000 psi Proof Test)
Temp: 375 F, 190 C
ESP cable
Triskelion Lower
Male & Female Connectors
Seal Fittings
Manifold Bushing
Male & Female Connectors
Triskelion Upper
Multiple Port
Type Packer
Dual String
Type Packer
Standard 3-Hole
Multiple Ports for
Additional Control Lines
Multiple Port Type
Packer
Dual String Type
Packer
Manifold Bushing Examples
March 2010 Rev.2

You might also like