PROBLEM 2.

1
KNOWN: Steady-state, one-dimensional heat conduction through an axisymmetric shape.
FIND: Sketch temperature distribution and explain shape of curve.
SCHEMATIC:
ASSUMPTIONS: (1) Steady-state, one-dimensional conduction, (2) Constant properties, (3) No
internal heat generation.
ANALYSIS: Performing an energy balance on the object according to Eq. 1.11a,

, E E
in out
= 0 it
follows that

E E q
in out x
=
and that q q x
x x
$. That is, the heat rate within the object is everywhere constant. From Fouriers
law,
q kA
dT
dx
x x
= ,
and since q
x
and k are both constants, it follows that
A
dT
dx
Constant.
x
=
That is, the product of the cross-sectional area normal to the heat rate and temperature gradient
remains a constant and independent of distance x. It follows that since A
x
increases with x, then
dT/dx must decrease with increasing x. Hence, the temperature distribution appears as shown above.
COMMENTS: (1) Be sure to recognize that dT/dx is the slope of the temperature distribution. (2)
What would the distribution be when T
2
> T
1
? (3) How does the heat flux, q
x
, vary with distance?
SOFTbank E-Book Center Tehran, Phone: 66403879,66493070 For Educational Use.
PROBLEM 2.17 (CONT.)
q q q V 0.601A 15.0 W/ m K
0.030 m C
0.015 m
q W= 49.5 W
iron heater ss
iron
= =

=
100
4
150
601 10 6
2
$
$
.
. .
where
q k A T x
ss ss c 2 2
= / .
Applying Fouriers law to the iron sample,
k
q x
A T
W 0.015 m
0.030 m C
W/ m K.
iron
iron 2
c 2
= =


=

49 5
4 150
70 0
2
.
/ .
.
$
<
The total drop across the iron sample is 15C(60/15) = 60C; the heater temperature is (77 + 60)C =
137C. Hence the average temperature of the iron sample is
T = 137 + 77 C/ 2 =107 C = 380 K. $ <
We compare the computed value of k with the tabulated value (see above) at 380 K and note the good
agreement.
(c) The principal advantage of having two identical samples is the assurance that all the electrical
power dissipated in the heater will appear as equivalent heat flows through the samples. With only
one sample, heat can flow from the backside of the heater even though insulated.
Heat leakage out the lateral surfaces of the cylindrically shaped samples will become significant when
the sample thermal conductivity is comparable to that of the insulating material. Hence, the method is
suitable for metallics, but must be used with caution on nonmetallic materials.
For any combination of materials in the upper and lower position, we expect T
1
= T
2
. However, if
the insulation were improperly applied along the lateral surfaces, it is possible that heat leakage will
occur, causing T
1
T
2
.