Pond Min Level 2099.5 m Average Water Level 2101.833333 m Centerline of Turbine 1796 m Tail waterLevel 1804 m Length of Head Race Tunnel 7317.415 m Dia of HRT (Modified Horse shoe shaped) 4.8 m Dia of Pressure shaft (Circular) 3.8 m Dia of Penstocks (Circular) 2.2 m Design Discharge 68.9 C S Area of HRT 18.2779497 C S Area of Pressure shaft 11.34114948 C S Area of Penstocks 3.801327111 No. of Penstocks 3 Discharge in each Penstock 22.96666667 Total Length of Pressure shaft 276.817181 Total Length of Penstock 79.68517006 Gross head at Turbine 297.8333333 Head Loss By Manning's Formula Manning's Coefficient n 0.012 0.012 Velocity in HRT 3.769569407 Velocity in Pressure shaft 6.075221927 Velocity in Penstock 6.04174963 Hydraulic Radius of HRT 1.199997397 Hydraulic Radius of PS 0.95 Hydraulic Radius of Penstock 0.55 Tunnel Head Loss 11.74167156 PS Head loss 1.558055206 Penstocks Head Losses 0.92949814 Total Head Losses 20.16 14.2292249 b 1.001377331 Ath 24.20269877 Diameter of SS required 5.551201056 Actual diameter 7 Actual area of SS 38.48451001 FOS 1.590091682 Net head during Normal operation 278.09 m 283.6041084 Net head during minimum operating condition 276.34 m 281.2707751 Area of Surge Shaft by Thoma's criteria F> Cross sectional Area of Surge Shaft F Length of Tunnel L Cross sectional Area of Tunnel f Velocity in Tunnel v Minimum dynamic hydraulic head H0 Head loss in Tunnel ho Cross sectional Area of Surge Shaft F 26.66 m2 30.34523575 Dia of of Surge Shaft 5.83 m 6.215847018 Say 6 m 6 Check % Head loss in the Tunnel 5.10 % 4.174508195 which is >4% as per Thoma's SURGE SHAFT HYDRAULIC DESIGN C S Area of Surge Shaft As Beta 0.826316528 Length of Tunnel L Cross sectional Area of Tunnel At Velocity in Tunnel v Minimum dynamic hydraulic head H0 Head loss in Tunnel hf 25 Area of Surge Shaft 29.33020587 26 Factor of Safety 1.6 27 Dia of of Surge Shaft 5.98 m 28 Dia of surge shaft Say 6 m Corrresponding cross sectional area of Surge Tank 28.27 m2 29 Area of Orifice Calme & Garden suggest the following Criterion for the resistance offered by the orifice. 30 Z is Surge height corresponding to change in discharge neglecting friction and orifice losses 31 Max. Surge height (Z) at Instantaneous load rejection 59.0201 Say 59 m Area of Orifice Opening hof is Head loss in Orifice for restricted orifice surge Tank 32 Area of Orifice Opening (A0) Assumed is 3.45 m2 33 Coefficient od discharge Cd (from IS code) 0.6 34 Design Discharge Q0 67.2 cumec h of 53.64 m 35 By adopting Orifice opening area of 2.5m2, Calme & Garden Criterion is satisfied. 46.77 m 56.85 m Check 46.77 < 53.64 < 57 36 Dia of Port 2.10 Say 2.1 m Hence Dia of Orifice to be provided 2.1 m As per IS : 7396 Pt I - 1985 s t o gA LA z V C A g Q h d o o of 2 2 2 2 v 2 h f b v H g LA v A o t s 2 2 2 b o f f f h Z h Z h 4 3 2 4 2 + + 2 4 f Z h + f h Z 4 3 2 + Page 2 of 2 2110 m 2103 m 2099.5 m 2101.3 m 1795.5 m 1803.0 m 7510.0 m 4.7 m 2.0 m 2.0 m 67.15 cumec 3.253572 (0.98758r)2 17.52 m2 p(dia)2 /4 3.14 m2 p(dia)2 /4 3.14 m2 3 Nos 22.38 cumec 299.50 m 298.25 m Bend r D r/D a k from fig2 Head Loss 1 50 4.8 10.41667 80.066 0.08 0.057939 2 25 4.8 5.208333 10.31 0.025 0.046512 3 25 4.8 5.208333 24.52 0.05 0.00367 4 20 4.8 4.166667 89.95 0.08 0.001233 0.109355 (v2/(2g))(Lf/(H0-h0)*h0 17.57 4.729779995 7.567647992