You are on page 1of 11

Gas & Steam Turbine Directory

Turbine Directory Contents


Gas Turbine Technical
Specifications
20
Steam Turbine Technical
Specifications
28
Products
Actuators
Air cleaners, dryers and filters
Air conditioning and refrigeration
Air heaters and preheaters
Air pollution monitors and CEMS
Alignment and balancing equipment
Bearings
Borescopes, videoscopes, fiberscopes
Burners and ignition systems
Castings
Coatings/lining materials
Cogeneration systems
Combined cycles
Combustion
air flow measurement
control and optimization systems
pressure monitoring
systems and burners
Compressors
air
gas
Computer-aided design and
engineering
Condenser tubes
Condensers
Controllers
airflow
energy management
meters and instruments
temperature monitoring
Control panels and consoles
Control systems
Corrosion prevention products
Couplings
Dampers
Desuperheaters
Detection systems, flame
Diagnostic systems
Drives
dampers
electronic
fluid
mechanical
variable speed
other
Ducts
Fans
Filters and filtration systems
Gas turbine inlet cooling
Gas turbines
Gas turbine parts, components and
accessories
Gasification systems
Gears
Generators
Heat exchangers
Heat recovery systems/HRSGs
Heaters
Indicators

www.PowerEngineeringInt.com

1404PEI_19 19

30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
30
31
31
31
31
31
31
31
31
31
31
31
31
31
31
31
31
31
31
32
32
32
32
32
32
32
32

flow
32
level
32
pressure
32
temperature
32
Inspection equipment
32
Instruments, measuring
32
Insulation
32
Leak detection
32
Lube-oil systems
32
Lubricants
32
Microturbines
32
Monitoring equipment
32
combustion control
32
continuous emission monitoring equipment 32
emissions
32
temperature
32
general
32
Nitrogen oxide control systems
32
Noise measurement and control
33
Oil
33
cleaning systems
33
conditioning equipment
33
oil/water separators
33
Piping
33
Pressure monitoring, measuring
33
Pumps
33
Reheaters
33
Remote monitoring
33
Safety equipment
33
Seals
33
Sensors
33
Spray nozzles
33
Steam generators
33
Steam turbines
33
Steam turbine parts, components and
accessories
34
Superheaters
34
Test equipment
34
Torque conversion
34
Turbomachinery controls
34
Valve actuators
34
Valves
34
Vibration
34
analysis
34
control
34
monitoring
34
Wear resistant coatings and parts
34

Services
Aftermarket parts and services
Air compressors, overhaul
and repair
Air pollution control services
Alignment/balancing
Bearings
Calibration
Cogeneration
Combustion diagnostics and testing
Condensers
cleaning
repair
retubing
Control system design and
maintenance
Corrosion control and monitoring
Fans
maintenance

34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34
34

rebuilding
repair
Filter services and maintenance
Gas turbine inlet cooling
design/engineering
maintenance/repair
Gas turbines
blade repair
installation
maintenance
overhauling
rebuilding
servicing
Gear repair
Generators
design
maintenance
rebuilding
repair
rewinding
Heat exchangers
coil upgrading
retubing
tube cleaning
tube plugging
Heat recovery/HRSGs
Inspection services
Instrumentation and control systems
calibration
maintenance
Life extension services
Lube oil
Maintenance services
Mechanical failure analysis
Metal fabricating and machining
Monitoring
Outage services
Pumps and compressors
overhauling
rebuilding
repair
Repair services, general
Steam generators, maintenance
and repair
Steam generators, nuclear
Steam turbines
aligning
blade repair
installation
maintenance
overhauling
rebuilding
Valves
reconditioning
repairing
testing
Vibration control
balancing
monitoring

Power Engineering International April 2014

34
34
34
34
34
34
34
34
34
34
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35
35

19

4/8/14 10:24 AM

Gas Turbine Technical Specifcations

Manufacturer

Model

Gross
output
(MW)

Net output
(CC) MW

GT24

230.7

GT26

Net output
(SC) MW

Heat rate
(kJ/kWh)

Gross
effciency (%)

Net effciency
(CC) (%)

Frequency
(Hz)

Shaft speed (rpm)

664

9000

40.0

58.4

60

3600

326

467

8933

40.3

59.5

50

3000

GT13E2

202.7

281

9474

38.0

53.5

50

3000

GT11N2

113.6

345

10,811

33.3

51.3

50

3610

GT11N2

115.4

349

10,619

33.9

51.8

60

3600

AE64.3A

75

111.7

73.5

10,028

35.90

53.75

50/60

3000/3600

AE94.2

185.3

277.4

181

9939

36.22

54.57

50

3000

AE94.2K

170

Case by case

Case by case

9863

36.50

Case by case

50

3000

AE94.3A

310

456.4

304

9045

39.80

58.86

50

3000

Alstom

Ansaldo Energia

Dresser -Rand

Manufacturer

GE Energy
(Heavy Duty,
Simple Cycle)

20

1404PEI_20 20

KG2-3G

14,100

25.5

50/60

25,500

KG2-3E

1.9

21,000

17.5

50/60

18,800

VECTRA
30G

23.9

9553

37.7

50/60

6200

VECTRA
40G

31.1

8963

40.2

50/60

6200

VECTRA
40G4

34.3

8916

40.4

50/60

6200

DR-61G

23.9

9588

37.5

50/60

3600

DR-61GP

31.4

9114

39.5

50/60

3600

DR-61G4

33.9

9104

39.5

50/60

3600

DR63GPC

44.3

8449

42.6

50/60

3600

DR63GPG

53.2

8346

43.1

50/60

3930

Model

Year

Net output (MW)

Heat rate (Btu/kWh)

Net heat rate (kJ/kWh)

Net effciency (%)

Pressure ratio

6B.03

1978

43.1

10,180

10,740

33.5

12.7

6F.03

2003

79.2

9470

9991

36.0

16.1

7E.03

1984

90

10,060

10,614

33.9

12.8

7F.04

2009

187

8850

9337

38.6

16.2

7F.05

2009

227

8680

9158

39.3

18.4

7HA.01

2012

275

8240

8694

41.4

21.5

7HA.02

2014

330

8240

8694

41.4

21.5

9E.03

1992

130

9860

10,403

34.6

12.9

9F.03

1996

265

9020

9517

37.8

16.7

9F.05

2003

299

8810

9295

38.7

18.3

9HA.01

2011

397

8220

8673

41.5

21.8

9HA.02

2014

470

8220

8673

41.5

21.8

Power Engineering International April 2014

www.PowerEngineeringInt.com

4/8/14 10:24 AM

Gas Turbine Technical Specifcations

Pressure
ratio

Exhaust mass
fow (kg/s)

Exhaust
temperature
(C)

NOx emissions
(ppmv)

Weight (tonnes)

Dimensions
LxWxH
(metres)

Comments

35.4:1

505

597

<25

230

10.7 x 4 x 4.6

CC performance refers to KA24-2 MS


(2-on-1 Multishaft confguration CCPP);
Dual fuel burner option available

35.0:1

692

603

<25

406

12 x 4.9 x 5.5

CC performance refers to KA26-1 SS


(1-on-1 Single shaft confguration CCPP);
Dual fuel burner option available

18.2:1

624

501

<25

350

11 x 5.4 x 5.5

CC performance refers to KA13E2-1 MS (1on-1 Multishaft confguration CCPP);


Dual fuel burner option available

15.9:1

400

526

<25

190

13.1 x 5.5 x 10.1

CC performance refers to KA11N2-2 MS


(2-on-1 Multishaft confguration CCPP); incl.
gear box, Dual fuel burner option available

15.9:1

400

526

<25

190

9.4 x 5.5 x 10.1

CC performance refers to KA11N2-2 MS (2on-1 Multishaft confguration CCPP);


Dual fuel burner option available

16.7

213

574

<25

Case by case

100

12 x 4 x 5

12.0

556

541

<25

Case by case

280

15 x 14 x 9

12.0

540

545

Case by case

Case by case

280

15 x 14 x 9

19.5

750

576

<25

Case by case

360

14 x 7 x 9

7.1

9.5

583

<24 ppm

16

6.7 x 2.1 x 2.7

4.5

15.0

560

60 ppm

16

6.7 x 2.1 x 2.7

47

7 x 4.1 x 5.6

0.5

18.2

68.7

545

SAC and DLE


available

21.9

84.4

531

SAC and DLE


available

47

7 x 4.1 x 5.6

23.6

90.1

541

SAC and DLE


available

47

7 x 4.1 x 5.6

18.2

69.5

533

SAC and DLE


available

45

7 x 4.1 x 5.6

22.5

87.3

515

SAC and DLE


available

45

7 x 4.1 x 5.6

23.0

91.6

527

SAC and DLE


available

45

7 x 4.1 x 5.6

27.6

125.7

454

SAC and DLE


available

50

7 x 4.1 x 5.6

31.1

141.4

471

SAC and DLE


available

50

7 x 4.1 x 5.6

Low BTU Fuels

Exhaust fow
(kg/s)

Frequency (Hz)

Turbine speed
(rpm)

Exhaust
temperature
(C)

Approx. weight
(tonnes)

Dimensions
L x W x H (metres)

145

50/60

5163

539

222

24 x 4 x 4

Available in 50 Hz & 60 Hz

214

50/60

5231

592

254

23 x 4 x 5

Available in 50 Hz & 60 Hz

292

60

3600

546

300

20 x 4 x 4

450

60

3600

601

480

24 x 7 x 4

533

60

3600

606

530

24 x 7 x 4

576

60

3600

618

600

25 x 5 x 7

690

60

3600

618

660

27 x 5 x 6

416

50

3000

542

410

21 x 5 x 5

665

50

3000

595

641

28 x 5 x 5

667

50

3000

639

724

28 x 5 x 5

826

50

3000

619

950

30 x 6 x 6

978

50

3000

619

1,050

33 x 6 x 6

www.PowerEngineeringInt.com

1404PEI_21 21

Start up time
(mins)

Comments

Power Engineering International April 2014

21

4/8/14 10:24 AM

Gas Turbine Technical Specifcations

Manufacturer

GE Energy
(Heavy Duty,
Combined Cycle)

Manufacturer

Kawasaki Heavy
Industries

Manufacturer

MAN Diesel & Turbo

Model

Gross plant output


(MW)

Year

Net plant output


(MW)

1x1 6B.03

1987

66

64.8

50.4

7141

1979

133.1

130.9

50.9

7069

1x1 6F.03

1991

120.4

118.4

55

6540

2x1 6F.03

1991

243.1

239.4

55.6

6470

1x1 9E.03

1979

198.1

195

52.1

6911

2x1 9E.03

1979

398.4

392.5

52.7

6837

1x1 9F.03

1994

408

403

58.1

6194

2x1 9F.03

1994

822

811

58.5

6158

1x1 9F.05

2002

461

455

59.5

6055

2x1 9F.05

2002

926

914

59.7

6027

1x1 9HA.01

2011

600

592

61.4

5862

2x1 9HA.01

2011

1195

1181

61.2

5878

1x1 9HA.02

2014

710

701

61.4

5862

2x1 9HA.02

2014

1415

1398

61.2

5878

1x1 6B.03

1987

66

64.8

50.4

7141

2x1 6B.03

1979

133.1

130.9

50.9

7069

1x1 6F.03

1991

120.4

118.4

55

6540

2x1 6F.03

1991

243.1

239.4

55.6

6470

1x1 7E.03

1977

137.6

135.4

51.1

7048

2x1 7E.03

1979

276.8

272.6

51.4

7007

1x1 7F.04

2009

286

283

58.8

6120

2x1 7F.04

2009

574

567

59

6107

1x1 7F.05

2009

347

343

59.3

6068

2x1 7F.05

2009

697

688

59.5

6054

1x1 7HA.01

2012

410

405

61.1

5892

2x1 7HA.01

2012

823

813

61.2

5878

1x1 7HA.02

2014

492

486

61.1

5892

2x1 7HA.02

2014

987

976

61.2

5878

Model

Gross output
(MW)

Heat rate
(kJ/kWh)

Gross
effciency (%)

Frequency
(Hz)

Shaft speed (rpm)

GPB300D
GPB180D

30.1

8977

40.1

50

Gas Generator Rotor 9330 / Power Turbine Rotor 5600

18.4

10,526

34.2

50

9420

GPB80D

7.8

10,714

33.6

50

13,800

GPB70D

6.7

12,000

30

50

13,800

GPB17D

1.7

13,382

26.9

50

21,965

GBP06

0.6

18,947

19.4

50

31,376

Model

Gross output
(MW)

Net output
(CC) MW

Net output
(SC) MW

Heat rate
(kJ/kWh)

Gross
effciency (%)

Net effciency
(CC) (%)

Frequency
(Hz)

Shaft speed
(rpm)

THM1304-10N

10.5

Case by case

10.08

11,840

30.4

Case by case

50/60

9000

THM1304-12N

12.5

Case by case

12.00

11,320

31.8

Case by case

50/60

9000

MGT6100

6.52

Case by case

6.52

11,250

32.0

Case by case

50/60

1500/1800

Model

Gross output
(MW)

H-15

17.03

10,409

MHPS
(Simple Cycle)

H-25(32)

32.3

10,341

H-25(35)

37.69

10,292

35.0

1404PEI_22 22

Net heat rate (kJ/kWh)

2x1 6B.03

Manufacturer

22

Net plant effciency


(%)

Power Engineering International April 2014

Heat rate
(kJ/kWh)

Gross effciency
(%)

Frequency (Hz)

Shaft speed (rpm)

34.6

50/60

9710

34.8

50/60

7280

50/60

7280

www.PowerEngineeringInt.com

4/8/14 10:24 AM

Gas Turbine Technical Specifcations

Condenser pressure
(inch Hg)

Frequency (Hz)

Gas turbine power (MW)

Steam turbine power (MW)

No. & type of gas turbine

1.2

50

42.578

23.445

1 x 6B.03

1.2

50

85.156

47.977

2 x 6B.03

1.2

50

78.619

41.742

1 x 6F.03

1.2

50

157.237

85.883

2 x 6F.03

1.2

50

128.650

69.404

1 x 9E.03

1.2

50

257.301

141.073

2 x 9E.03

1.2

50

262.864

145.490

1 x 9F.03

1.2

50

525.728

295.792

2 x 9F.03

1.2

50

297.521

163.576

1 x 9F.05

1.2

50

595.038

330.697

2 x 9F.05

1.2

50

394.472

205.191

1 x 9HA.01

1.2

50

789.352

405.920

2 x 9HA.01

1.2

50

467.008

242.922

1 x 9HA.02

1.2

50

934.497

480.560

2 x 9HA.02

1.2

60

42.578

23.445

1 x 6B.03

1.2

60

85.156

47.977

2 x 6B.03

1.2

60

78.619

41.742

1 x 6F.03

1.2

60

157.237

85.883

2 x 6F.03

1.2

60

89.148

48.466

1 x 7E.03

1.2

60

178.296

98.490

2 x 7E.03

1.2

60

185.903

100.549

1 x 7F.04

1.2

60

371.805

202.666

2 x 7F.04

1.2

60

226.234

121.041

1 x 7F.05

1.2

60

452.468

244.346

2 x 7F.05

1.2

60

273.418

136.782

1 x 7HA.01

1.2

60

546.836

276.028

2 x 7HA.01

1.2

60

328.101

164.138

1 x 7HA.02

1.2

60

656.203

331.233

2 x 7HA.02

Pressure ratio

Turbine inlet
temperature
(C)

Exhaust mass
fow (kg/s)

Exhaust
temperature
(C)

NOx
emissions
(ppmv)

Start up time
(mins)

Weight
(tonnes)

Dimensions
LxWxH
(metres)

24.5

1270

87.2

470

15

15

250

22 x 7.1 x 13.8

Two shaft gas turbine

18.3

1250

59.8

542

15

15

190

18 x 4.9 x 9.8

Single shaft gas turbine

15.9

1160

27.3

523

15

6.6

75

14.5 x 3.5 x 8.1

Single shaft gas turbine

15.9

1160

27.0

513

25

6.6

75

14.5 x 3.5 x 8.2

Single shaft gas turbine

10.5

1035

521

60 seconds.

35

8.4 x 2.75 x 6.3

Single shaft gas turbine

8.5

<1035

5.05

474

36

60 seconds.

15

6.3 x 2.2 x 5.8

Single shaft gas turbine

Comments

Pressure ratio

Turbine inlet
temperature
(C)

Exhaust mass
fow (kg/s)

Exhaust temperature (C)

NOx emissions
(ppmv)

Weight (tonnes)

Dimensions
LxWxH
(metres)

Comments

10

46.5

490

<25 @ 70-100% load

Case by case

77

16 x 3 x 5

incl. generator

11

49.1

515

<25 @ 70-100% load

Case by case

77

16 x 4 x 6

incl. generator

28.0

465

<15 @ 50-100% load

Case by case

Pressure ratio

Exhaust mass fow (kg/s)

Exhaust temperature (C)

Weight (tonnes)

14.8

53.3

556

200

20 x 6 x 11

14.8

96.6

562

300

18 x 10 x 14

17.3

112.1

556

409

24 x 10 x 14

www.PowerEngineeringInt.com

1404PEI_23 23

Dimensions L x W x H (metres)

Power Engineering International April 2014

23

4/8/14 10:24 AM

Gas Turbine Technical Specifcations

Manufacturer

MHPS
(Simple Cycle)

Manufacturer

MHPS
(Combined Cycle)

24

1404PEI_24 24

Gross output
(MW)

Heat rate
(kJ/kWh)

Gross effciency
(%)

Frequency (Hz)

Shaft speed (rpm)

H-25(42)

42.03

9667

37.2

50/60

7280

H-80

112.44

9421

38.2

50

3000

H-80

110.61

9585

37.6

60

3600

MF-61

5.925

12,566

28.7

50/60

13,800

MF-111

14.57

11,627

31

50/60

9660

MFT-8

26.78

9306

38.7

50/60

5000

MF-221

30

11,258

32

50/60

7200

M701DA

144.09

10,351

34.8

50

3000

M701F4

324.3

9028

39.9

50

3000

M701G2

334

9106

39.5

50

3000

M701F5

359

9000

40

50

3000

M701JAC

445

< 8784

> 41

50

3000

M701J

470

8784

41.0

50

3000

M501DA

113.95

10319

34.9

60

3600

M501F3

185.4

9739

37

60

3600

M501G1

267.5

9211

39.1

60

3600

M501GAC

276

9047

39.8

60

3600

M501JAC

310

< 8784

> 41

60

3600

M501J

327

8784

41

60

3600

Model

Model

Gross output (MW)

Heat rate (kJ/kWh)

1x1 H-25(32)

47.9

7080

1x1 H-25(32)

96.7

7013

1x1 H-25(35)

55.59

7071

2x1 H-25(35)

112.18

7007

1x1 H-25(42)

59.93

6889

2x1 H-25(42)

120.76

6825

1080 H-80

160.64

6660

2080 H-80

329.78

6494

1080 H-80

159.61

6691

2080 H-80

327.62

6519

MPCP1(M701)

214.49

7000

MPCP2(M701)

430.58

6974

MPCP3(M701)

650.97

6974

MPCP1(M701F4)

482.3

6000

MPCP2(M701F4)

967.6

5981

MPCP1(M701G)

506.3

6071

MPCP2(M701G)

1016

6051

MPCP1(M701F5)

530

5902

MPCP2(M701F5)

1063.3

5883

MPCP1(M701JAC)

675

< 5902

MPCP1(M701J)

687

5835

MPCP1(M501)

169.2

7000

MPCP2(M501)

339.9

6974

MPCP3(M501)

511.75

6974

MPCP1(M501F)

287.8

6305

MPCP2(M501F)

577.600

6283

MPCP1(M501G)

402.000

6165

MPCP2(M501G)

806.7

6144

MPCP1(M501GAC)

414.8

6051

MPCP2(M501GAC)

830.9

6041

MPCP1(M501JAC)

450

< 5902

MPCP1(M501J)

475

5854

MPCP2(M501J)

952.9

5835

Power Engineering International April 2014

www.PowerEngineeringInt.com

4/8/14 10:24 AM

Gas Turbine Technical Specifcations

Pressure ratio

Exhaust mass fow (kg/s)

Exhaust temperature (C)

Weight (tonnes)

Dimensions
L x W x H (metres)

17.3

111

556

409

24 x 10 x 14

19.3

308

538

563

37 x 12 x 15

19.2

307

545

563

37 x 12 x 15

15

27

496

10

3.7 x 2.5 x 3.1

15

54

530

22

5.5 x 2.8 x 2.5

21

86

463

7.1 x 2.5 x 2.5

15

107

532

50

7.7 x 3.7 x 3.4

14

440

542

200

12.5 x 5.2 x 5.2

18

712

591

419

17.4 x 5.8 x 5.8

21

737

587

420

18.3 x 6.1 x 6.1

21

712

610

481

17.4 x 5.8 x 5.8

23

861

615

23

861

637

561

18.3 x 7.1 x 7.1

14

346

542

145

11.6 x 5.8 x 4.3

16

458

613

195

14.1 x 4.6 x 4.6

20

598

600

334

15.3 x 5.5 x 5.5

20

598

617

271

15.3 x 5.5 x 5.5

23

598

612

318

15.3 x 5.5 x 5.5

23

598

635

318

15.3 x 5.5 x 5.5

Frequency (Hz)

Condensate Pressure (inch Hg)

Gas turbine power (MW)

50/60

1.2

31.1

50/60

1.2

62.2

50/60

1.2

36.4

50/60

1.2

72.8

50/60

1.2

40.6

50/60

1.2

81.2

50

1.2

109.5

50

1.2

218.4

60

1.2

108

60

1.2

214.6

50

1.5

142.1

50

1.5

284.2

50

1.5

426.3

50

1.5

319.9

50

1.5

639.8

50

1.5

325.7

50

1.5

651.4

50

1.5

354

50

1.5

708

50

1.5

445

50

1.5

463

60

1.5

112.1

60

1.5

224.2

60

1.5

336.3

60

1.5

182.7

60

1.5

365.4

60

1.5

264.4

60

1.5

528.8

60

1.5

273.6

60

1.5

547.2

60

1.5

310

60

1.5

322

60

1.5

644

www.PowerEngineeringInt.com

1404PEI_25 25

Power Engineering International April 2014

25

4/8/14 10:24 AM

Gas Turbine Technical Specifcations

Model

Gross output
(MW)

FT8 MOBILEPAC

25.4

Manufacturer

PW Power Systems

Manufacturer

Rolls-Royce

Siemens AG
Energy Sector

26

1404PEI_26 26

Net output
(CC) MW

Net output
(SC) MW

Heat rate
(kJ/kWh)

Gross
effciency (%)

34.9

25.2

LHV Gross HR 10,370 kJ/kWh

FT8 SWIFTPAC 30

41.1

30.1

LHV Plant Net HR 7333 kJ/kWh

FT8 SWIFTPAC 60

83.1

60.5

LHV Plant Net HR 7257 kJ/kWh

FT4000 SWIFTPAC 60

83.9

67.6

LHV Plant Net HR 7250 kJ/kWh

FT4000 SWIFTPAC 120

169.0

136.2

LHV Plant Net HR 7193 kJ/kWh

Model

Gross output
(MW)

Net output
(CC) MW

Net output
(SC) MW

Heat rate
(kJ/kWh)

Gross
effciency
(%)

Net effciency
(CC) (%)

Frequency
(Hz)

Shaft speed
(rpm)

RB211-G62 DLE

37.7

26.7

12

7175

50.2

50/60

4800

RB211-GT62 DLE

39.7

28.6

12.2

7005

51.4

50/60

4800

RB211-GT61 DLE

42.6

31.1

12.59

6820

52.8

50/60

4850

Trent 60 DLE

65.3

50.7

15.82

6718

53.6

50

3000

Trent 60 DLE

78.3

50.7

29.3

6936

51.9

50

3000

Trent 60 DLE ISI

77.6

61.9

17.1

6736

53.4

50

3000

Trent 60 DLE ISI

94.1

61.9

34.2

6992

51.5

50

3000

Trent 60 WLE

81.2

64.4

18.2

6998

51.4

50

3000

Trent 60 WLE

107.2

64.4

45.3

7339

49

50

3000

Trent 60 WLE ISI

82.8

66

18.4

7022

51.2

50

3000

Trent 60 WLE ISI

109.5

66

46.2

7355

48.9

50

3000

Trent 60 DLE

66.4

51.6

16

6725

53.5

60

3600

Trent 60 DLE

79.6

51.6

29.7

6945

51.8

60

3600

Trent 60 DLE ISI

75.4

60.2

16.6

6727

53.5

60

3600

Trent 60 DLE ISI

90.8

60.2

32.6

6969

51.6

60

3600

Trent 60 WLE

77.9

61.7

17.6

6998

51.4

60

3600

Trent 60 WLE

102.4

61.7

43.1

7340

49

60

3600

Trent 60 WLE ISI

80.3

64

17.7

7093

50.7

60

3600

Trent 60 WLE ISI

105.7

64

44.2

7404

48.6

60

3600

SGT-200

7.68

10,776

33.4

50/60

SGT-300

7.90

11,773

30.6

50/60

SGT-400

12.90

10,355

34.8

50/60

SGT-400

14.33

10,178

35.4

50/60

SGT-500

19.06

10,690

33.7

50/60

SGT-600

24.48

10,720

33.6

50/60

SGT-700

32.82

9675

37.2

50/60

SGT-750

37.03

9120

39.5

50/60

SGT-800

47.50

9557

37.7

50/60

SGT-800

50.50

9407

38.3

50/60

SGT5-2000E

172

10,190

35.3

50

3000

SGT5-4000F

307

9001

40

50

3000

SGT5-8000H

375

8999

40

50

3000

SGT6-2000E

114

10,496

34.3

60

3600

SGT6-5000F

232

9278

38.8

60

3600

SGT6-8000H

274

8999

40

60

3600

Power Engineering International April 2014

www.PowerEngineeringInt.com

4/8/14 10:24 AM

Gas Turbine Technical Specifcations

Net effciency (CC) (%)

Shaft speed
(rpm)

Pressure ratio

Exhaust mass fow


(kg/s)

Exhaust
temperature (C)

NOx emissions
(ppmv)

50/60

19.9

88

469

25

Net Effciency LHV = 49.1

50/60

21.3

91

490

25

Net Effciency LHV = 49.6

50/60

21.3

182

490

25

Net Effciency LHV = 49.6

50/60

36.2

176

431

25

Net Effciency LHV = 50

50/60

36.2

351

431

25

Pressure ratio

Turbine inlet
temperature
(C)

Exhaust mass
fow (kg/s)

Exhaust
temperature
(C)

NOx emissions
(ppmv)

Start
up time
(mins)

Weight
(tonnes)

Dimensions
L x W x H (metres)

Comments

20.35

90.4

25

18.5 x 4 x 5

2P unfred

21.39

94.1

25

18.5 x 4 x 5

2P unfred

21.29

92.4

25

18.5 x 4 x 5

2P unfred

33.81

152.2

25

26.52 x 4.57 x 18.9

2P unfred

33.81

152.2

25

26.52 x 4.57 x 18.9

2P fred to 1112F (600C)

38.73

174.1

25

29.56 x 4.57 x 18.9

2P ISI unfred

38.73

174.1

25

29.56 x 4.57 x 18.9

2P ISI fred to 1112F (600C)

38.9

176.3

25

26.52 x 4.57 x 18.9

2P unfred

38.9

176.3

25

26.52 x 4.57 x 18.9

1P fred to 1300F (704C)

39.43

178.9

25

29.56 x 4.57 x 18.9

2P ISI unfred

39.43

178.9

25

29.56 x 4.57 x 18.9

1P ISI fred to 1300F (704C)

34.1

153.3

25

26.52 x 4.57 x 18.9

2P unfred

34.1

153.3

25

26.52 x 4.57 x 18.9

2P fred to 1112F (600C)

37.99

166.2

25

29.56 x 4.57 x 18.9

2P ISI unfred

37.99

166.2

25

29.56 x 4.57 x 18.9

2P ISI fred to 1112F (600C)

36.87

167

25

26.52 x 4.57 x 18.9

2P unfred

36.87

167

25

26.52 x 4.57 x 18.9

1P fred to 1300F (704C)

37.81

178.1

25

29.56 x 4.57 x 18.9

2P ISI unfred

37.81

178.1

25

29.56 x 4.57 x 18.9

1P ISI fred to 1300F (704C)

12.3

29.5

493

25

13.7

30.2

542

15

16.8

39.4

555

15

18.9

44.3

539

15

13.0

97.9

369

42

150,139

21.3 x 4 x 3.7

14.0

81.3

543.

25

122,924

19.2 x 4.6 x 4

18.7

95.0

533

15

143,789

19.2 x 4.6 x 4

23.8

114.2

458.5

15

20.4

132.8

541

15

171,900

17 x 4.5 x 4

21.1

134.2

553

15

171,900

17 x 4.5 x 4

12.1

531.0

537

216,000

14 x 12.5 x 8.5

18.8

723.0

579

312,000

11 x 4.9 x 4.9

19.2

829.0

627

390,000

13.1 x 4.9 x 4.9

12.1

367.0

537

163,000

11.6 x 10.4 x 7

18.9

551.0

593

193,000

10.1 x 4 x 4

19.5

604.0

617

286,000

11 x 4.3 x 4.3

www.PowerEngineeringInt.com

1404PEI_27 27

Frequency (Hz)

Power Engineering International April 2014

27

4/8/14 10:24 AM

Steam Turbine Technical Specifcations

OEM

Alstom

Model

Power rating

Shaft speed

(MW)

(rpm)

Dimensions LxWxH (metres)

Inlet temp.
(oC)

Inlet
pressure
(bar)

Gas fow rate


(m3/h)

GRT

CCPP/Biomass/Industrial applications/
Waste-to-Energy (WtE)/CSP/Conventional
power plants/Geothermal

565

420011,000

3.6 x 14 (30 MW turbine


+ generator, typical)
4.7 x 20 (60 MW turbine +
generator, typical)

540

125

n/a

MT

CCPP/Biomass/Industrial applications/
WtE/CSP/Conventional power plants/
Geothermal

50100+

30003600

Depending on confguration

565

140

n/a

COMAX

Cogneration applications

100400

30003600

Depending on confguration

565

140

n/a

STF15C

Combined-cycle power plants

100250

30003600

Depending on confguration

565/565

165/15

n/a

STF30C

Combined-cycle power plants

150400

30003600

Depending on confguration

585/585

185/45

n/a

STF25

Steam power plants

100350

30003600

Depending on confguration

540/540

540/540

n/a

STF40

Steam power plants

250700

30003600

Depending on confguration

600/620

300/65

n/a

STF60

Steam power plants

500900

30003600

Depending on confguration

600/620

300/65

n/a

STF100

Steam power plants

7001200

30003600

Depending on confguration

600/620

300/65

n/a

STN series

Nuclear applications (full-speed)

100800

30003600

Depending on confguration

250290

4275

Adaptable to
any reactor

ARABELLE
1000

Nuclear applications (full-speed)

8001300

15001800

Depending on confguration

250290

4275

Adaptable to
any reactor

Nuclear applications (full-speed)

13001900

15001800

Depending on confguration

250290

4275

ARABELLE
1700

Ansaldo
Energia

Type/Application

MT10

Combined cycle

40250

50/60 Hz applicable

1-cylinder

Non re-heat

MT20

Combined cycle

150350

50/60 Hz applicable

2-cylinder

Non re-heat

MT15

Combined cycle, Fossil, Solar

90300

50/60 Hz applicable

2-cylinder

Re-heat

RT30

Combined cycle, Fossil

150400

50/60 Hz applicable

3 to 4 cylinder

Re-heat

RT70

Fossil

4001000

50/60 Hz applicable

4 to 5 cylinder

Re-heat

Adaptable to
any reactor

A200

Combined cycle

70220

3000

Up to 538

Up to 103

Up to 750

D200

Combined cycle

180330

3000

Up to 538

Up to 103

Up to 1090

A450

Combined cycle

150290

3000

Up to 600

Up to 131

Up to 750

D400

Combined cycle

230440

3000

Up to 600

Up to 131

Up to 940

A650

Combined cycle

150300

3000

Up to 600

Up to 166

Up to 750

D600

Combined cycle

230550

3000

Up to 600

Up to 166

Up to 1090

D650

Combined cycle

230550

3000

Up to 600

Up to 166

Up to 1090

A200

Combined cycle

50200

3600

Up to 538

Up to 103

Up to 750

D200

Combined cycle

120300

3600

Up to 538

Up to 103

Up to 1090

GE Energy

A450

Combined cycle

100250

3600

Up to 600

Up to 131

Up to 750

D400

Combined cycle

180400

3600

Up to 600

Up to 131

Up to 940

A650

Combined cycle

100260

3600

Up to 600

Up to 166

Up to 750

D600

Combined cycle

180500

3600

Up to 600

Up to 166

Up to 1090

D650

Combined cycle

180500

3600

Up to 600

Up to 166

Up to 1090

Standard
Low-pressure
turbines
Air turbines
MARC 1
MAN Diesel
& Turbo

28

1404PEI_28 28

Power generation

2160

50/60 Hz

Power generation

590

50/60 Hz

CAES (compressed air energy storage)

2590

50/60 Hz

540

140

24

50 Hz

450

65

Combined heat and power (CHP)generation


for Renewable energy and WtE

540
Saturated
steam

140
120

MARC 2

CHP generation for reneable energy and WtE

510

50 Hz

520

90

MARC 4

CHP generation for reneable energy and WtE

820

50 Hz

520

120

MARC 6

CHP generation for reneable energy and WtE

1640

50 Hz

530

120

Power Engineering International April 2014

www.PowerEngineeringInt.com

4/8/14 10:24 AM

Steam Turbine Technical Specifcations

OEM

Model

ITT-30/40-2,9

ITT-65/75-130/13

Condensing turbine with steam reheat for


industrial purposes and district heating/TPP
Backpresure turbine / TPP

ITT-90/100-

Condensing turbine with steam reheat for

130/13-1M

industrial purposes and district heating/TPP

KT-115-8,8

Siemens AG
Energy Sector

Condensing turbine with steam reheat for


industrial purposes and district heating/TPP

P-50/60-130

P-85-8,8/0,2

Power
Machines
OJSC

Type/Application

Backpresure turbine /TPP


Condensing turbine with steam extraction for

Inlet

Shaft speed

(MW)

(rpm)

30/40

3000

9.8 x 5.3 x 4.3

410

2.9

220

65/75

3000

14.3 x 5.3 x 4.2

555

12.8

400

50/60

3000

8.9 x 3.6 x 4.6

555

12.8

490

91

3000

14.8 x 6.5 x 4

555

12.8

470

85

3000

9.5 x 3.6 x 2.43

535

8.8

450

Dimensions LxWxH (metres)

temp.
(oC)

Inlet pressure

Gas

Power rating

(bar)

fow rate
(m3/h)

115

3000

14.4 x 5.6 x 2.9

500

8.8

446

K-210-130-8

Condensing turbine /TPP

210

3000

19 x 6.5 x 5.5

540

12.8

640

K-255-162-2

Condensing turbine /TPP

255

3000

22.7x 11.4 x 6.8

540

15.9

700

K-165-130

Condensing turbine /TPP

165

3000

14.6 x 7.6 x 5.8

540

12.8

480

K-225-12,8-3

Condensing turbine /TPP

225

3000

20 x 8.5 x 5.7

540

12.8

540

K-168-107

Condensing turbine /TPP

167

3000

17.1 x 8.5 x 5.7

525

10.5

442

K-110-6,5

Condensing turbine / CCP

110/114

3000

16.4 x 8.5 x 5.7

497

6.5

309.3

district heating / TPP

T-110-140

Condensing turbine/TPP

110/123

3000

17.2 x 5 x 5.2

535

13.7

326

T-120-12,8

Condensing turbine /TPP

120

3000

14.9 x 5.9 x 5.1

565

12.8

470

T-125/150-7,4

Condensing turbine / CCP

125

3000

16.6 x 8.5 x 5.7

500

7.4

525

T-130/160-12,8

Condensing turbine /TPP

130/160

3000

15.3 x 8.5 x 5.5

555

12.8

500

T-150-7,7

Extraction turbine / CCP

150/160

3000

17 x 8.5 x 5.7

510

7.7

309.3

T-185/210-16,0-P

Extraction turbine / TPP

186/210

3000

23.6 x 9.6 x 6.1

558

16

576

K-300-170-1P

Condensing turbine /NPP

300/310

3000

24.7 x 11.4 x 6.9

540

16.7

960

K-330-23,5

Condensing turbine /TPP

330

3000

21.2 x 8.9 x 6.1

540

23.5

1050

K-800-130/3000

Condensing turbine /TPP

885

3000

41.6 x 11.4 x 6.9

485

12.8

3180

K-660-247

Condensing turbine /TPP

660/686

3000

36.5 x 9.8 x 6

537

24.3

2023.8

K1000-60/300

Condensing turbine /NPP

1030

3000

51.8 x 11.4 x 6.9

274.3

5.88

5870

K-1000-60/3000-2

Condensing turbine /NPP

995

3000

41.8 x 11.4 x 6.9

274.3

5.88

5980

K-1000-60/3000-3

Condensing turbine /NPP

1014

3000

33.8 x 16.3 x 7.8

274.3

5.88

5980

K -1200-6,8/50

Condensing turbine /NPP

1200

3000

53 x 11.4 x 6.9

505

6.8

4793

2.5 x 1.5 x 2

Up to 400

Up to 40

SST-040

Up to 0.3

SST-050

Up to 0.750

1 x 1 x 1.3

SST-060

Up to 6

1.5 x 2.5 x 2.5

SST-100

Up to 8.5

SST-110

Up to 7

SST-111

Up to 12

SST-150

Up to 20

SST-200

Up to 10

SST-300

Up to 50

SST-400

Up to 7500

8 x 3.7 x 3.4

Up to 131
Up to 480

6 x 2.8 x 3.2

Up to 65
Up to 131

9x4x4

Up to 530

Up to 131

12 x 4 x 5

Up to 505

Up to 103

4 x 2 x 2.5

Up to 520

Up to 110

Up to 12000

12 x 4 x 5

Up to 520

Up to 120

Up to 65

30008000

18 x 8.5 x 5.5

Up to 540

Up to 140

SST-500

Up to 100

Up to 15000

19 x 6 x 5

Up to 400

Up to 30

SST-600

Up to 150

300018,000

19 x 6 x 5

Up to 565

Up to 165

SST-700

Up to 175

300013,200

22 x 15 x 6

Up to 585

Up to 165

SST-800

Up to 250

30003600

20 x 8.5 x 6

Up to 565

Up to 170

SST-900

Up to 250

30003600

20 x 11 x 10

Up to 585

Up to 165

SST-6000

3001200

Up to 600

Up to 300

SST-5000

120750

Up to 600

Up to 190

SST-3000

90250

Up to 565

Up to 177

Up to 540

Up to 140

Up to 540

Up to 140

Up to 540

Up to 140

Up to 580

Up to 165

SKODA MTD20

SKODA MTD25

Single-casing/Fossil, CCPP, Renewables

Single-casing/Fossil, CCPP, Renewables

Up to 35

Up to 45

Up to 13300

8000, 50/60 Hz
applicable
6500, 50/60 Hz
applicable

Up to
15,000

Doosan Skoda
SKODA MTD30

Single-casing/Fossil, CCPP, Renewables

Up to 60

SKODA MTD40

Single-casing/Fossil, CCPP, Renewables

Up to 200

www.PowerEngineeringInt.com

1404PEI_29 29

5500, 50/60 Hz
applicable
3000/3600, 50/60 Hz
applicable

Power Engineering International April 2014

29