You are on page 1of 4

Project Name:

Project No.:
Location:
LOCAL RAINFALL INTENSITY: (From ASPE Databook or Applicable Code):
SECONDARY DRAINS: (100 YEAR OCCURANCE, 15 MINUTE DURATION):
PRIMARY DRAINS: (100 YEAR OCCURANCE, 60 MINUTE DURATION):
DEPTH OF WATER OVER THE PRIMARY SCUPPER:
DEPTH OF WATER OVER THE SECONDARY SCUPPER:
PIPE COEFFICIENT OF ROUGHNESS (n):
SLOPE OF HORIZONTAL PIPES (FOOT PER FOOT):
Roof Roof Tributary Total Required Size of Size of Width of Width of
Designation Area Wall Area Area Overflow Overflow Overflow Secondary Primary
(See (Sq. Feet)(Sq. Feet) To Be Drain Horizontal Vertical Scupper Scupper
Sketch) See Note 1Drained Capacity Pipe Pipe (Inches) (Inches)
(Sq. Feet) (GPM) (Inches) (Inches)
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
0 0 0 0 0 0
Note: Standard pipe sizes are 2,3,4,5,6,8,10,12,15,18 and 21inches. Please use these sizes on the drawings.
CALCULATIONS:
HORIZONTAL PIPE SIZE (FLOWING FULL): MANNING FORMULA:
Q=(1.486/n)*A*R^.667*S^.5 OR DIA = 12*((GPM/448.7)(N)/(0.5*S^0.5))^0.375
ROOF DRAINAGE CALCULATIONS
SECONDARY DRAINS PRIMARY DRAINS
WHERE: Q=FLOW IN CFS; A=AREA, Sq. Feet; R = HYDRAULIC RADIUS, Feet; S = SLOPE, FT/FT; n = COEFFICIENT OF ROUGHNESS
VERTICAL PIPE SIZE (FLOWING 7/24 FULL):
GPM =27.8(7/24)^1.666(D)^2.667 OR DIA = 0.617(GPM)^.375
PRIMARY SCUPPER:
GPM = 4489.86(3.33(W*12-0.2H*12)(H*12)^1.5)
OVERFLOW SCUPPER:
GPM = 4489.86(3.33(W*12-0.2H*12)(H*12)^1.5)
WHERE: W = WIDTH OF SCUPPER (Inches) H = HEAD (Depth) OF WATER OVER BOTTOM OF SCUPPER (Inches)
2 Inches for Primary Scuppers
1 Inch for Secondary or Overflow Scuppers
Notes: 1. Adjusted wall areas should be put into the spreadsheet as the entire square footage. This number will be
adjusted by the spreadsheet to calculate only one-half of the square footage in the calculation.
2. The smallest pipe size available is 4 inches in the calculation. If you have a small roof area, verify if a
smaller pipe size could be used in accordance with the applicable code.
Date:
Inches/Hr GPM/Sq. Ft.
4 0.042
4 0.042
2
1
0.0145
0.01 Percentage
Required Size of Size of
Primary Primary Primary
Drain Horizontal Vertical
Capacity Pipe pipe
(GPM) (Inches) (Inches)
0 0 0
0 0 0
0 0 0
0 0 0
0 0 0
0 0 0
0 0 0
0 0 0
0 0 0
0 0 0
0 0 0
0 0 0
0 0 0
0 0 0
0 0 0
0 0 0
0 0 0
0 0 0
0 0 0
0 0 0
0 0 0
0 0 0
0 0 0
0 0 0
Note: Standard pipe sizes are 2,3,4,5,6,8,10,12,15,18 and 21inches. Please use these sizes on the drawings.
ROOF DRAINAGE CALCULATIONS
PRIMARY DRAINS
WHERE: Q=FLOW IN CFS; A=AREA, Sq. Feet; R = HYDRAULIC RADIUS, Feet; S = SLOPE, FT/FT; n = COEFFICIENT OF ROUGHNESS
WHERE: W = WIDTH OF SCUPPER (Inches) H = HEAD (Depth) OF WATER OVER BOTTOM OF SCUPPER (Inches)
1. Adjusted wall areas should be put into the spreadsheet as the entire square footage. This number will be
2. The smallest pipe size available is 4 inches in the calculation. If you have a small roof area, verify if a