Technical Data

WEP-4204J/K
WEP-4208J/K
Telemetry Systems
2
DESIGN FEATURES
High resolution, 12.1-inch color display
This thin and compact color telemetry system has a
high resolution, wide-viewing angle TFT color LCD
for easy viewing. Various display patterns available.
Digital signal transmission
All Nihon Kohden products use digital signal trans-
mission to reduce noise and interference.
Dual diversity antenna
The dual diversity antenna method prevents signal
loss, so secure signal transmission is always avail-
able.
Touch panel and touch pen
A touch panel and touch pen provide easy and quick
operation. You can directly write the patient name on
screen with the touch pen or finger. Any characters
and figures can be displayed.
Arrhythmia detection
Up to 64 (WEP-4204) or 128 (WEP-4208) arrhyth-
mia episodes are stored and reviewed easily. The
multi-template matching method assures high quality
arrhythmia detection and prevents false alarms.
3-ch built-in recorder
A 3 channel built-in thermal array recorder is stan-
dard. A handwritten patient name is also printed as
is.
Alarm indicator
An alarm indicator at the top of the monitor can be
seen clearly from a distance. It lights in red or
yellow to indicate the severity of the alarm.
Full disclosure (option)
Using an optional flash disk card*, full disclosure
ECG is available. Up to 200 (WEP-4208) or 100
(WEP-4204) hours for all patients combined can be
displayed and recorded. This option also increases
the total number of arrhythmia recall files to 1024 for
all patients combined, and allows trendgraphing of
all measured parameters.
SPECIFICATIONS
Receiver
Reception frequency: 420 to 472 MHz, synthesizer
method
Antenna: Space diversity (dual antenna system)
Receiving sensitivity: 10 dBVEMF
Spurious radiation: 4 nW max.
Display
Number of patients:
WEP-4204: 4
WEP-4208: 8
Display size: 12.1 inch, TFT type color LCD
Screen size: 246 185 mm
Resolution: 800 600 dots
Waveform display method: Non-fade, fixed or
moving method
Display waveform parameters: ECG, pulse (SpO
2
),
respiration, IBP (WEP-4204), CO
2
Number of waveforms:
WEP-4204:
All patient screen, row display: 2 waves/patient
All patient screen, column display: 7 waves/patient
Individual screen: 5 waves + 4 patients ECG
WEP-4208:
All patient screen: 1 wave/patient
Individual screen: 3 waves + 8 patients ECG
Sweep speed: 25 or 50 mm/s (normal), 6.25 mm/s
(compressed), 1.56 mm/s (low-speed respiration)
Waveform display time:
WEP-4204: 7.4 s (at 25 mm/s) with no dominant QRS
display
WEP-4208: 6 s (at 25 mm/s) with no dominant QRS
display
Colors: 12, selectable
Numerical data display: Heart rate (or pulse rate),
VPC rate, ST level, respiration rate, NIBP (systolic,
diastolic and mean), SpO
2
, temperature, IBP (systolic,
diastolic and mean, WEP-4204), CO
2
Synchronization: Heart rate, pulse rate, respiration
rate
Screen Layout
WEP-4204:
All patient screen
type A: Screen is divided into 4 rows. 2 waveforms
for each patient and all measured numeric data, and
dominant ECG are displayed.
type B: Screen is divided into 4 columns. 7 traces of
one cascaded waveform for each patient, all mea-
sured numeric data, and dominant ECG are displayed.
48 s for disclosed ECG is displayed and scrolled in
each 8 s. 4 min (2 min for ECG) short trend or nu-
meric data in 3 s steps is displayed for one patient.
3
Individual screen
All waveforms, numeric data and dominant ECG of
selected patient. Other patients ECG and heart or
pulse rate is also displayed at the same time.
WEP-4208
All patient screen
type A: Screen is divided into 8 rows. 1 waveform for
each patient and all measured numeric data are
displayed.
type B: Screen is divided into 2 (columns) 4 (rows).
1 waveform for each patient and all measured
numerica data are displayed
Individual screen
3 waveforms, numeric data and dominant ECG of
selected patient. Other patients ECG and heart or
pulse rate is also displayed at the same time.
Alarm
Items: Heart rate (or pulse rate), SpO
2
, NIBP (systolic,
diastolic and mean), respiration rate, temperature, IBP
(systolic, diastolic and mean, WEP-4204), CO
2
, apnea,
arrhythmia, NOISE, CHECK ELECTRODES, DE-
TECTING PULSE, CHECK PROBE, SIGNAL LOSS,
CALL, LOAD REC PAPER, CLOSE PAPER MAGA-
ZINE and low battery
Alarm types: Crisis (red, blinking), Warning (yellow,
blinking), Advisory, Message
Alarm indication: Highlighted message, alarm sound,
and alarm indicator
Alarm suspend: Provided (for a 1 or 2 minute period)
Alarm recording: Automatic
ECG Monitoring
ECG leads: I, II, III, MCL, ECG 1, ECG 2
Waveform display:
Sensitivity control: 1/4, 1/2, 1, 2, 4, auto
Pacing pulse count elimination: provided
Hum filter: provided
Heart rate counting range: 0, 12 to 300 beats/min
2 beats/min
Alarm limits:
Upper: 20 to 300 beats/min, Off, 5 beat steps
Lower: Off, 15 to 295 beats/min, 5 beat steps
Alarm items: TACHYCARDIA, BRADYCARDIA,
ASYSTOLE, VF, VT, VPC RUN, COUPLET, EARLY
VPC, BIGEMINY, FREQ VPC
ST level display range: 2.50 to 2.50 mV
Respiration Monitoring
Sensitivity control: 1/4, 1/2, 1, 2, 4
Measuring range: 0 to 150 breaths/min 2 breaths/
min
Respiration rate alarm limits:
Upper: 2 to 150 breaths/min, Off, 2 breath steps
Lower: Off, 0 to 148 breaths/min, 2 breath steps
Apnea alarm limit: Off, 5 to 40 s
SpO
2
Monitoring
Sensitivity control: 1/8, 1/4, 1/2, 1, 2, 4, 8
Measuring range: 50 to 100%, in 1% steps (The
accuracy depends on the transmitter used)
Alarm limits:
Upper: 51 to 100%, Off, 1% steps
Lower: Off, 50 to 99%, 1% steps
Non-invasive Blood Pressure Monitoring
Display value: Systolic, diastolic, and mean pres-
sures
Pressure display range: 0 to 300 mmHg 1% +1
readings (The accuracy depends on the transmitter
used)
Alarm limits:
Upper: 15 to 260 mmHg, Off, 5 mmHg steps
Lower: Off, 10 to 255 mmHg, 5 mmHg steps
Invasive Blood Pressure Monitoring
WEP-4204 only
Display value: Systolic, diastolic and mean pressures
Measuring range: 50 to 300 mmHg (The accuracy
depends on the transmitter used)
Alarm limits:
Upper: 2 to 300 mmHg, Off, 2 mmHg steps
Lower: Off, 0 to 298 mmHg, 2 mmHg steps
CO
2
Monitoring
Measuring range: 0 to 99 mmHg (The accuracy
depends on the transmitter used)
Alarm limits:
Upper: 0 to 99 mmHg, Off, 2 mmHg steps
Lower: Off, 1 to 98 mmHg, 2 mmHg steps
Temperature Monitoring
Measuring range: 5 to 45C 0.2C (The accuracy
depends on the transmitter used)
Alarm limits:
Upper: 5.5 to 45C, Off, 0.5C steps
Lower: Off, 5 to 44.5C, 0.5C steps
Pulse Rate Monitoring
Measuring range: 0, 12 to 300 beats/min 2 beats/
min
Alarm limits:
Upper: 20 to 300 beats/min, Off, 5 beat steps
Lower: Off, 15 to 295 beats/min, 5 beat steps
4
Arrhythmia Recall
VPC detection method: Multi-template matching
method software algorithm
VPC rate counting range: 0 to 99 VPCs/min
Arrhythmia alarm: ASYSTOLE, V FIB, V TACHY,
VPC RUN, COUPLET, EARLY VPC, BIGEMINY,
FREQ VPC, TACHYCARDIA, BRADYCARDIA
Recall file capacity: 64 (WEP-4204) or 128 (WEP-
4208) for all patients combined, 1024 for all patients
combined with QM-421P flash disk card
Waveform storage time per file: 8 s
Trendgraph
Trend parameters: Heart rate (or pulse rate), respira-
tion rate, VPC, ST level, EVENT, apnea (time), apnea
(frequency), SpO
2
, NIBP (systolic, diastolic, mean),
IBP (systolic, diastolic, mean, WEP-4204), tempera-
ture, CO
2
All parameters trendgraphing available with QM-421P
flash disk card
Trend time: 1, 2, 4, 8 or 24 hours
Vital Signs List
List items: Heart rate (or pulse rate), respiration rate,
VPC, NIBP (systolic, diastolic, mean), SpO
2
, IBP
(systolic, diastolic, mean, WEP-4204), temperature,
CO
2
List capacity:
Periodic: 120 sets/patient
NIBP list: 120 sets/patient
List interval:
Periodic list: 1, 5, 15, 30, 60 min
NIBP list: when NIBP is measured
Full Disclosure ECG
Requires QM-421P flash disk card (built-in option)
Storage capacity:
WEP-4208: 200 hours for all patients combined
WEP-4204: 100 hours for all patients combined
Built-in Recorder
Method: Thermal array recording
Number of channels: 3
Effective printing width: 48 mm
Paper speed: 25 or 50 mm/s
Annotation printing: Patient name, bed ID, date and
time, reason for recording, parameter data, beat
classification, ECG related messages, ECG lead, filter
On/Off, sensitivity, recording speed
Network Printer
Requires QI-111P network printer card, Purchase
network printer locally
Printer: HP LaserJet 4100N or compatible recom-
mended
Print modes: Trend, list, recall, full-disclosure ECG, one-
shot waveforms
Power Requirements
Power supply:
WEP-4204/4208J: 100 - 127 V AC, 50/60 Hz
WEP-4204/4208K: 220 - 240 V AC, 50/60 Hz
Power consumption: 80 VA
External Output
PCMCIA interface: For software upgrade
External display interface: AUX socket on the right
side panel, Analog RGB output, 0.7 Vp-p/75,
HSYNC 39 kHz (TTL, negative), VSYNC 62.5 Hz
(TTL, negative)
Serial communication interface: AUX socket on the
right side panel
Environment
Operating temperature: 10 to 40C
Operating humidity: 30 to 85% RH, non-condensing
Operating atmospheric pressure: 70 to 106 kPa
Storage temperature: 20 to 65C
Storage humidity: 10 to 95% RH, non-condensing
Storage atmospheric pressure: 70 to 106 kPa
Dimensions and Weight
Dimensions: 339W 375H 159D mm, excluding
antenna and base
Weight:
WEP-4204: 8 kg, excluding options
WEP-4208: 9 kg, excluding options
Electromagnetic Compatibility
IEC60601-1-2 (1993-04) - Collateral Standard: Electro-
magnetic compatibility - Requirements and tests
Emissions: CISPR11 Group I, Class B
Safety Standard
Safety standard: IEC60601-1 (1988) - General
requirements for safety Amendment 1 (1991-11),
Amendment 2 (1995-03)
5
STANDARD ACCESSORIES
Qty
Power cord H (for J version) 1
Power cord N (for K version) 1
Antenna 2
Name plate and pen 1
Touch pen 1
Thermal head cleaner pen 1
Recording paper 1
Disposable electrode Vitrode C (30 pcs/pack) 1
Name label 1
OPTIONAL ACCESSORIES
Flash disk card, QM-421P
Network printer card, QI-111P
Grounding lead, 544582
Fuse T2.0A/250V, 104522
Cart, KC-009P
RGB cable, for connecting a display monitor, YS-
072P5
PC connection cable, YS-074P5
Band pass filter
Wall mount kit, product of GCX
Adaptor for wall mount kit, DI-950P
CONSUMABLES
A723 Recording paper, FQW50-3-100
Y011 Thermal head cleaning pen, 5 pcs/set
ORDERING INFORMATION
When ordering, please specify the following informa-
tion:
1) Power line voltage and frequency
2) Requirements for optional accessories
3) Requirements for consumables
4) Specify part order code in
According to the type of protection against electri-
cal shock: CLASS I EQUIPMENT
According to the degree of protection against
harmful ingress of water: IPX0 (Ordinary EQUIP-
MENT)
According to the degree of safety of application in
the presence of a FLAMMABLE ANAESTHETIC
MIXTURE WITH AIR, OR WITH OXYGEN OR NI-
TROUS OXIDE: EQUIPMENT not suitable for use in
the presence of FLAMMABLE ANAESTHETIC MIX-
TURE WITH AIR, OR WITH OXYGEN OR NITROUS
OXIDE
According to the mode of operation: CONTINU-
OUS OPERATION
This brochure may be revised or replaced by Nihon Kohden at any time without notice.