You are on page 1of 2

G made ent i rel y of st ai nl ess st eel

G short response t i mes


G vari ous sensor di amet ers
GR/ OP
KROHNE 0 3 / 2 0 0 2 7 .0 2 4 2 0 .2 2 .0 0
Temperat ure sensor
TTP 200
www.krohne.com
Vari abl e area fl owmet ers
Vort ex fl owmet ers
Fl ow cont rol l ers
El ect romagnet i c fl owmet ers
Ul t rasoni c fl owmet ers
Mass fl owmet ers
Level measuring inst rument s
Communi cat i ons t echnol ogy
Engi neeri ng syst ems & sol ut i ons
Swi t ches, count ers, di spl ays and recorders
Heat met eri ng
Pressure and t emperat ure
TTP 2 0 0
TTP 200
Techni cal dat a
Primar y head TTP 2 0 0
Operat ing principle t emperat ure sensor PT 1 0 0
Process condit ions
Pressure 1 6 bar
Process t emperat ure -2 0 +1 5 0 C
M at erials
Probe st ai nl ess st eel 1 .4 5 7 1
PT 1 0 0 , Cl ass A, DIN EN 6 0 7 5 1
Housi ng st ai nl ess st eel 1 .4 3 0 5
Process connect ion
Screwed j oi nt G
1
/ 2 h, sensor t i ps 6 , 4 , 3 mm
Mount i ng l engt h 2 0 ; 5 0 ; 1 0 0 ; 1 5 0 ; 2 5 0 mm
Elect ronic unit
Si gnal convert er fi xed measuri ng ranges or
freel y programmabl e, PROFIBUS PA
Signal out put PT 1 0 0 resi st or or
4 t o 2 0 mA
Di mensi ons
Elect rical connect ion cabl e gl and
M1 6 or M1 2 pl ug
Type of prot ect ion
EN 6 0 5 2 9 IP 6 7
Accessories
Wel d-i n sl eeve HWN 2 0 0
Hygi eni c sl eeve of 1 .4 5 7 1 st ai nl ess st eel , wi t h wel di ng mark for defi ned
al i gnment of t he cabl e gl and or M1 2 pl ug
Hygi eni c adapt er sl eeves avai l abl e for ot her process connect i ons
Soft ware for user set t i ng of t he measuri ng range
Al t ernat i vel y: speci fy measuri ng range when orderi ng
The screw-i n TTP 2 0 0 t emperat ure sensor wi t h st ai nl ess st eel connect i on head i s desi gned
for use i n processes demandi ng hi gh st andards of hygi ene ( e.g. breweri es, dai ri es, beverage
and pharmaceut i cal i ndust ri es) . The max. measuri ng range i s -2 0 t o +1 5 0 C. A PT 1 0 0
chi p, Cl ass A, t o DIN EN 6 0 7 5 1 i n 2 -, 3 - or 4 -wi re t echnol ogy i s fi t t ed as st andard i n t he
sensor casi ng. An anal og or programmabl e si gnal convert er can be i nst al l ed for dat a t rans-
mi ssi on wi t h 4 2 0 mA st andardi zed si gnal or Profi bus PA.
5 5
5
8
SW 2 2
G1 / 2 "
Kabel verschraubung M1 6
E
i
n
b
a
u
l

n
g
e

L
L
L
6
3
7
8
St eckverbi nder M1 2
M
1
2
x
1
4 3
3
0
3
0
Pl ug-i n connect or M 1 2
Cabl e gl and M 1 6
M
o
u
n
t
i
n
g

l
e
n
g
t
h

L
L
L
Uni t ed Ki ngdom
KROHNE Lt d.
Rut herford Dri ve
Park Farm Indust ri al Est at e
Wel l i ngborough,
Nort hant s NN8 6 AE, UK
TEL.: +4 4 ( 0 ) 1 9 3 3 -4 0 8 5 0 0
FAX: +4 4 ( 0 ) 1 9 3 3 -4 0 8 5 0 1
e-mai l : i nfo@krohne.co.uk
USA
KROHNE Inc.
7 Dearborn Road
Peabody, MA 0 1 9 6 0
TEL.: +1 - 9 7 8 5 3 5 -6 0 6 0
FAX: +1 - 9 7 8 5 3 5 -1 7 2 0
e-mai l : krohne@krohne.com
Ot her count ri es
KROHNE Messt echni k GmbH & Co. KG
Ludwi g-Krohne-St r. 5
D- 4 7 0 5 8 Dui sburg
TEL.: +4 9 ( 0 ) 2 0 3 -3 0 1 - 0
FAX: +4 9 ( 0 ) 2 0 3 -3 0 1 3 8 9
e-mai l : food@krohne.de

You might also like