You are on page 1of 32

05/06/2014

Products Solutions Services


Endress+Hauser Product Portfolio
Linh Tran Slide 1
05/06/2014
Flow Measurement - Overview
The Proline
Concept
Calibration
Promag
Promass
Prosonic Flow
Prowirl
T-mass
DP-Flow
Linh Tran
5/17/2014
Slide 2
05/06/2014
PORTFOLIO FOR LIQUIDS
Promass
All Liquids
SS, alloy, titanium,
zirc.
0,1%
DN1250
-200+350C
400bar
Advantage
All liquids
No inlet run
High precision
Multivariable
Drawbacks
Pressure drop
High price

Prosonic
All liquids
SS
0.5%(0.3%)
DN25300
-40+150C
40bar
Advantage
All liquids
no pressure drop
2 wires
Drawbacks
5 x DN
Prowirl
All liquids
SS, alloy 0.7%
DN15300
-200+400C
160bar (250bar)
15 x DN
Advantage
All liquids
2 wires
Drawbacks
15 x DN
Pressure drop
Promag
Conductive liquid
PTFE, PFA
0.2..0.5%
DN15300 (600)
-20+150C
40 bar
5 x DN / 3 X DN
Advantage
No pressure drop
Drawbacks
Inlet run
only conductive liquid
PRICE
Performance
The Proline
Concept
Calibration
Promag
Promass
Prosonic Flow
Prowirl
T-mass
DP-Flow
Linh Tran
5/17/2014
Slide 3
05/06/2014
PORTFOLIO FOR GAS
Promass
All gas
SS, Alloy, Titan,
Zirkon.
0,1%
DN1250
-200+350C
400bar
Advantage
Direct mass
No inlet run
High precision
Multivariable
Drawbacks
Pressure drop
High price
for Gas up to 2 bar

T-mass
20 gaz in standard
1,5%
DN151500
-40+130C
40bar
5x DN U/D (DN15..100)
Advantage
Direct mass
measurement
Pressure drop (<2mbar)
Leakage detection
(min. Flow)
Only 5 x DN U/D
(with flow conditioner)
Low cost solution
Drawbacks
limited to < 25m/s
Deltatop/set
All gas
13%
DN1512000
-200+1000C
40 bar
15 x DN
Advantage
All Gas
Several material
Drawbacks
> 15 x DN
Pressure drop
Price
Performance
Prowirl 73+Hart
All gas
SS, Alloy
1 %
DN15300
-200+400C
160bar
15 x DN
Advantage
All Gas
2 wires
Cheap Solution
Drawbacks
15 x DN U/D
Pressure drop
Low flow configurable
The Proline
Concept
Calibration
Promag
Promass
Prosonic Flow
Prowirl
T-mass
DP-Flow
Linh Tran
5/17/2014
Slide 4
05/06/2014
PORTFOLIO FOR STEAM
Deltatop/set
All type of steam
13%
DN1512000
-200+1000C
40 bar
15 x DN U/D
Advantage
Versatile Sol
material
Drawbacks
> 15 x DN
Pressure drop
Price
Performance
Prowirl 73+HART
Saturated and
superheated
SS, Alloy
1 %, DN15300
-200+400C
160bar (250bar)
15 x DN
Advantage
Sat or superheated
2 wires
cheap
Drawbacks
15 x DN
pressure drop
low flow adjustable
Prowirl 72+RMC
Sat or superheated
SS, Alloy
1 %
DN15300
-200+400C
160bar (250bar)
15 x DN
Advantage
Sat or superheated
2 wires
Drawbacks
15 x DN
Pressure drop
Low flow adjustable
Prowirl 73
Saturated steam
SS, Alloy
1 %, DN15300
-200+400C
160bar (250bar)
15 x DN
Advantage
2 wires
Cheap
Drawbacks
15 x DN U/D
pressure drop
Low flow
adjustable.
The Proline
Concept
Calibration
Promag
Promass
Prosonic Flow
Prowirl
T-mass
DP-Flow
Linh Tran
5/17/2014
Slide 5
05/06/2014
Products Solutions Services
Proline Promass
Linh Tran Slide 6
05/06/2014
Why Measure Mass?
Temperature / Pressure

Volume 1 Volume 2

Mass 1 = Mass 2
Masse 1
Volumen 1
Masse 2
Volumen 2
Principle
Segmentation
Transmitters
Sensors
Advantages
Installation
Accessories
Applications
Linh Tran
5/17/2014
Slide 7
05/06/2014
Overview of direct measuring variables
D=Phase shift
m=Mass flow

fR=Resonance
frequency
r=Density

W= Resistance
(PT1000)
T=Temperature
~ m
f
R
~
~ T
Linh Tran
Principle
Segmentation
Transmitters
Sensors
Advantages
Installation
Accessories
Applications
5/17/2014
Slide 8
05/06/2014
Promass Sensors
Promass A Promass E
Promass F
Promass M Promass I Promass H
Promass F HT
Promass P
Promass S
Linh Tran
Principle
Segmentation
Transmitters
Sensors
Advantages
Installation
Accessories
Applications
5/17/2014
Slide 9
05/06/2014
5/17/2014
Linh Tran Slide 10
05/06/2014
5/17/2014
Linh Tran Slide 11
05/06/2014
5/17/2014
Linh Tran Slide 12
05/06/2014
Products Solutions Services
Promag Magmeters
Linh Tran Slide 13
05/06/2014
Measuring Principle Electromagnetic Flowmeter
Linh Tran
U
flow
= induced
voltage
v = flow velocity
Q = volume flow
Q = v * A
U
flow
~ v
History
Principle
Segmentation
Transmitters
Sensors
Selection
Installation
Accessories
Applications
5/17/2014
Slide 14
05/06/2014
5/17/2014
Linh Tran Slide 15
05/06/2014
Products Solutions Services
DP- flow
Linh Tran Slide 16
05/06/2014
5/17/2014
Linh Tran
Principle & range
Orifice plates
Pitot tubes
Nozzles
Venturi tubes
Accessories &
Installation
Deltabar Evolution
Applications
Slide 17
05/06/2014
5/17/2014
Linh Tran Slide 18
05/06/2014
5/17/2014
Linh Tran
Principle & range
Orifice plates
Pitot tubes
Nozzles
Venturi tubes
Accessories &
Installation
Deltabar Evolution
Applications
Slide 19
05/06/2014
root venturi
D dp-flow
V venturi
6 generation
primary type generation

1 venturi tube
version
mounting
S solutions
5/17/2014
Linh Tran
Principle & range
Orifice plates
Pitot tubes
Nozzles
Venturi tubes
Accessories &
Installation
Deltabar Evolution
Applications
Slide 20
05/06/2014
Products Solutions Services
Prowirl Vortex Flowmeter
Linh Tran Slide 21
05/06/2014
All you need for vortex measurement
f = Vortex frequency
V = Volume flow
f ~ V
Linh Tran
Bluff Body
DSC Sensor
Transmitter
5/17/2014
Slide 22
05/06/2014
Prowirl 72/73 - At a Glance
4...20 mA / HART
pulse output
PROFIBUS PA / FF
Ex i / Ex d, CE, NAMUR
-200...400C
up to PN 250 / ANSI class 1500
Wafer version DN 15...150
Flanges DN 15...300
Remote version up to 30m
Wetted parts made from NACE
MR 0175 listed materials
Dual sense available for
redundant measuring
Accuracy 0.75% for liquids
1.00% for gases
Linh Tran
Principle
Segmentation
Transmitters
Sensors
Installation
Applications
Digital Com
Plant Safety
5/17/2014
Slide 23
05/06/2014
5/17/2014
Linh Tran Slide 24
05/06/2014
Products Solutions Services
Prosonic Flow
Linh Tran Slide 25
05/06/2014
The Principle of PROline Prosonic Flow
t ~ Q
t = time differential
Q = volume flow
The time of the ultrasonic signal flow against the flow is
slower than the signal with the flow.
This results in a signal run time difference, which is
proportional to the flow rate.
The Transit Time Principle
Linh Tran
Principle
Clamp-on
Transmitters
Clamp-on Sensors
Clamp-on
Installation
Inline Meters
Inline Meters
Installation
Applications
5/17/2014
Slide 26
05/06/2014
Basic sensor types
Clamp-on
+ Easy Installation
+ Contact free
- Spacing crucial
Wetted and Inline
+ Independent of sonic
conductivity of pipe material
+ not affected by changing
temperatures
- In contact with liquid =
corrosion might be an issue
Linh Tran
Principle
Clamp-on
Transmitters
Clamp-on Sensors
Clamp-on
Installation
Inline Meters
Inline Meters
Installation
Applications
5/17/2014
Slide 27
05/06/2014
PROline Prosonic Flow W
Size range: DN50...4000
Non-hazardous area
Protection type IP 67 (IP68
optional)
Temperature range -
20...+130C
(Insertion up to +80C)

All you need for water
applications
Clamp-on sensors
Insertion Sensor
for welding in
Linh Tran
The Water Sensors
Principle
Clamp-on
Transmitters
Clamp-on Sensors
Clamp-on
Installation
Inline Meters
Inline Meters
Installation
Applications
5/17/2014
Slide 28
05/06/2014
Prosonic Flow 92F Ideal for non-conductive liquids
World-First Loop powered transmitter
(2-wire) with HART, PROFIBUS PA or
FOUNDATION Fieldbus.
Size range from DN25/1 to DN300/12
Pressure range PN16...PN40/Class
150300.
Temperature range -40.200C/ -
40.300F.
The material of all wetted parts is Stainless
Steel 1.4404/316L/316. Body A351-CF3M
Accuracy 0.5% optional 0.3% for 4 beam
systems
Requirement to straight run before the
meter < 5 x DN after bends in one or two
planes.
Hazardous area protection for gas and dust
available through intrinsically safety (Ex i)
or explosion proof (Ex d).
Linh Tran
Principle
Clamp-on
Transmitters
Clamp-on Sensors
Clamp-on
Installation
Inline Meters
Inline Meters
Installation
Applications
Digital Com
Plan Safety
5/17/2014
Slide 29
05/06/2014
Products Solutions Services
T-mass
Linh Tran Slide 30
05/06/2014
Mass flow measurement based on thermal dispersion
A heated temperature sensor is kept
at a constant differential
temperature from the gas reference
sensor.

The cooling effect generated by mass
flow causes an increase in sensor
power to maintain the temperature
differential.

The power supplied to the heated
sensor is proportional to the mass
flow.
Mass flow is measured directly
Mass Flow = Density x
Velocity

The measuring principle
Slide 31
Principle
Transmitters
Sensors
Selection
Calibration
Installation
Accessories
Applications


5/17/2014
Linh Tran
Slide 31
05/06/2014
Products Solutions Services
Thank you for your attention
Linh Tran Slide 32