Node B Commissioning divvied in 6 parts

Load New Software restoring A CBU


Cabinet Equipment configuration Element manager Wizard
!" Access Configuration # Element manager Wizard
Site Equipment Configuration # Element manager Wizard
$un Command file # Element manager
Create C% and $eload wit& t&is C% '(alidation)#create configuration %ersion
Load New Software restoring a CBU
1. Connecting a Thin Client (TC
!. Setting Up a serial connection
A serial cable and a serial *$+#,- adapter are required to connect to CBU .
Connect t&e serial adapter to t&e communication port 'C"/) f t&e t&in client
'0C)
Connect t&e serial cable to t&e serial adapter .
1f applicable2 remo(e an3 serial cable connected to CBU .
Connect t&e serial cable to serial port 'test 4ort ) of t&e CBU
". Config#ring $%per terminal
Clic5 start in window and select program2 &ccessories and comm#nication. clic5
t&e $%per Terminal .
'rom t&e file menu 2 c&oose New connection
03pe a name for t&e new Name te6t bo6. 7or e6ample $S898.
Select an icon for t&e connection from t&e icon and t&en clic5 5
(. 'ormatting the CBU hard )rive
*eload 'restart t&e $BS in bac5up mode )
'ormathd +c! 'format t&e &ard dri(e partition c8) Confirm wit& :;<
0&e $BS replies :formatting &ard disc o5 == $estart s3stem to initialize disc==.
$estart t&e $BS in bac5up mode. using t&e following command > $eload
,. Setting an *BS -assword .
-assword 'set t&e 4assword )
0&e $BS replies wit& t&e following information > :enter new 4assword :
Enter t&e New password /*BS Specific password 0
0&e $BS replies wit& t&e following information > : $e#enter new 4assword :
Confirm t&e new password /*BS Specific password 0
6. Setting an 1- Config#ration .
Set t&e 14 configuration 2 using t&e ifconfig Command >
E6ample . ifconfig le2 /*BS 1- address0 Netmas3 /
$eplace 1- &ddress and netmas3 wit& t&e addresses of $BS node.
C&ec5 t&e 14 configuration using t&e ifconfig command >
ifconfig
4. )ownloading a Basic C5 'rom a TC to CBU.
Start t&e 704 Client >
E6ample 6S7'T-
Connect to $BS 2 using t&e ip address> E6#/?@.8-,././ Enter user name $BS and
password
0ransfer t&e Basic C% directories c8 and d drom t&e 0C to t&e root director3 of t&e
$BS.
E6it t&e 704 client w&en t&e file transfer is complete
Note. #se 8inar% transfer mode in the 'T- client for all file transfers.
9. *estart the *BS #sing the following commend in $%per Terminal
*eload
0&e $BS $estart wit& t&e basic C%. t&e process can ta5e a few minutes.
:. &ccessing Node B #sing ;lement manager
Accesses t&e Element manager >
$eplace 14 address wit& t&e 14 address Aesigned for t&e $Bs Node
12. <8s . for assessing the ;lement manager it sho#ld 8e have internet e=plorer
and >ava .
Ca8inet e?#ipment config#ration
Element "anager Wizard
0o start t&e wizard 2 select t&e Cabinet Equipment option on t&e E" configuration
menu
1. -reconditions .
!. 'ile inp#t
Use configuration file '.6m file)
Automatic 'No Wizard) or wizard.
". <ther and sector
<@A &ccess Config#ration
Element "anager Wizard
/. 0o start t&e wizard2 select t&e !" Access option on t&e E" configuration menu.
Site Equipment configuration
Element "anager Wizard
/. 0o start t&e wizard2 select t&e Site ;?#ipment option on t&e E" configuration menu.
Node B integration instr#ctions for ;ricsson ""29B "C19 and "C26
models
D License server
;our printout will contain a line called fingerprint2 record t&e info and send to Ericsson
ASA4
7orce t&e $BS into BACBU4 mode using t&e commands in t&e serial window below2
D *eloadEF F
Now format t&e $BS &ard dis5s using t&e following commands2 responding wit& ; w&en
prompted to continue. Note. All data on t&e &ard dis5 will be destro3ed.
D formathd +d 'ignore $estart message)
D formathd +c!
D 5ols '3ouCll see DE on bot& C8 and d dri(e)
nce t&e second format command &as completed enter t&e following command
D reloadF F
Wit& t&e $BS 9DDD is in t&e :BACBU4< mode2 proceed to t&e ne6t section to set t&e $BS
9DDD Et&ernet 14 address2 using t&e following format. Use t&e $BS address from 3our
edited A".mo file.
D ifconfig le2F$BS 14GaddressHnetmas3F$BS sub#netmas5GaddressH
%erif3 t&e 14 address.
D ifconfig
Set 14 address of 3our laptop / &ig&er t&an t&at of t&e Node B Start 6SF'T- form 3our
laptop2 and configure t&e 704 session for 3our $BS. Set t&e pat& in t&e Local S3stem
window to point to t&e Basic 4ac5age 'CI4@D/8@-@G$?BND92 t&is is not 4? but a basic
(ersion of 4J) being loaded. Before 3ou transfer ma5e sure t&e Node window is in t&e
&ome director3 it will loo5 li5e t&is * 1f t&ere is a d present 3ou are not in t&e rig&t director3
0ransfer t&e *c8 and *d dri(es2 t&is usuall3 ta5es about /- minutes.
D reload
Set Cloc3.
D setcloc3 %%%%FmmFdd hh.mm.sec
D readcloc3
*emem8er to add , hrs to the c#rrent ho#rs 8eca#se it is 8ased on Greenwich time
Hone.
Script Loading Step !.
L<&)1NG Script 'iles.
La#nch ;A&S.
;ou will need to run t&e Cabinet Equipment Configuration first. "a5e sure 3ou set t&e
cabinet t3pe correctl3 '9/D? for standard outdoor cabinets). Set t&e correct number of
4SUs2 Batter3 set to amperage &ours of batteries. C&ange t&e 14 address from default
tosite 14.
Load t&e <am&ccess.=ml script file wit& !" Access Configuration Select
6iHard configuration.
At t&is point wait until all LEAs on t&e boardCs turns Solid Kreen and Solid range and
CBU goes Solid Kreen and 7las&ing range. 0&is ma3 ta5e up to /- minutes
$econnect to E"AS.
Ko to License from t&e drop down menu2 if 3ou &a(e t&e correct LB7 load it2 if not rig&t
clic5 on LicenseL/2 go to properties and set emergenc3 LB7
Load t&e e=ternal7hw.=ml wit& t&e Site Equipment Configuration. Select Wizard
configuration
Load t&e SiteComplete.mo wit& $un Command 7ile. 0&en Create a New C%
E6ample> BMD,?D/G4reG4JGDG8G/,
BS/9JDG4reG4J
Not in rollbac5 list &it appl3 button
Now set t&e new to startable and load t&at C%. Warm restart is o5.1n N3per terminal reset
t&e password.
D passwd
D /password0 i.e D r8s==== (==== I*BS site 1)
D /password0 i.e D r8s ==== ( ==== I*BS site 1)
Upgrade S6 Step ".
Jo# will need Cesar 'T- and ;A&S for this step
E6tract files from UpgradeG4ac5ageGW1NAG4J74G$/DBGJ
"o(e unzipped folder to C dri(e
pen Caesar 704
Clic5 on t&e :Little "an< for :User ! Kroups Settings<
O Clic5 on 98D? 'or ot&er appropriate group)
O Clic5 on :Anon3mous Access< button in Account Setup area 'Note> not&ing muc&
&appens w&en 3ou clic5)
O Clic5 on :7ile Access $ig&ts< button 7ind folder w&ere upgrade pac5age was e6tracted
and &ig&lig&t in one of two top windows
O Arag and drop to bottom left &and window2 w&ere it s&ould become a sub#folder of 98D?
'or w&ate(er appropriate group is being used)
O "o(e t&e window out of t&e wa3 to see t&e pre(ious window be&ind it Clic5 B on t&at
window
Launc& Element "anager
O C&ange to Software (iew and e6pand
O $ig&t#clic5 on Upgrade pac5ages and select Create
O 7ill in t&e name of t&e upgrade pac5age CI4@D/8@-@G$/DBEJ
O 7ill in t&e 14 address of 3our LA404 'not t&e site)
O 7ill in t&e pat& name from 'and including) t&e folder c&osen in Caesar to t&e proper file
wit& e6tension '.6ml) E6ample *CI4@D/8@-@G$/DBEJ*CI4@D/8@-@E/G$/DBEJ.6ml
O Clic5 on :Create 4ac5age<P.and wait
O W&en create pac5age disappears2 clic5 install and delete pac5age will be in boldon t&e
rig&t side of t&e screen2 clic5 on :1nstall 4ac5age< and t&en :7ull 1nstall<Pt&is ma3 ta5e up
to 9D minutes
Note 0&e s3stem will &a(e to restart at least once during t&is Note ;ou ma3 need to
refres& t&e screen to see an3 updates
O W&en t&e installation is complete2 clic5 on :Upgrade Node< and select QNard Upgrade<
Note 0&e s3stem will &a(e to restart at least once during t&is
Note ;ou ma3 need to refres& t&e screen to see an3 updates
O nce t&e cabinet &as stabilized 't&is can ta5e up to 9Dmin) 3ou ma3 need toreconnect to
E"AS
O nce 3ou &a(e reconnected got to t&e Software screen2 rig&t clic5 on pac5age go to
properties and clic5 on Confirm Upgrade2 clic5 3es to ma5e permanent
O Create a final C% E6ample C%D/G BMD,?D/G$/DBJ
O Set startable2 and reload.
Call Test Step (.
Call $NC to de#bloc5 t&e Utran and t&e Cell $eser(e. 0&en do call testing.