Refrigerator Model:HRF-669FF/A

1
note: HRF-669FF/A no home bar exits
Part1.Specifications
Model HRF-669FF/A HRF-689FF/A
Cavity Supply(V/Hz) 220~240/50 220~240/50
Power Consumption(kWh/year)
533 747
Unit Dimensions (WDH WDH/mmXmmXmm) 930X770X1750 930X860X1750
Unit Weight(Kg) 138 166
Box Dimensions(WDH/mmXmmXmm) 1010X833X1845 1010X923X1845
Box Weight(Kg) 153 176
Box Cubic(Cubic meter) 1.5 1.7
Container Quantity(40Hc) 31 26
Specifications are subject to change without prior notice.
Model HRF-669FF/A series
HRF-689FF/A series
Refrigerator Model:HRF-669FF/A
2
Refrigerator Model:HRF-669FF/A
3
Part3. Principle of Electric Control
Schematic Circuit Diagram
Brief Description of Control Principle
Refrigerator Model:HRF-669FF/A
4
HRF-689FF/A is the forced air cooling refrigerator with two doors(side by side). A
mechanical type of all the control is generally adopted. The thermostat directly controls
the start and stop of compressor, and hence the refrigerator temperature.
Low Temperature Compensation in the above schematic diagram,
When the ambient is below the set temperature, the switch will be
closed and the heating will work, thus ensuring the normal start, and
operation of refrigerator at lower ambient temperature, in such case,
the freezer compartment temperature can reach a good point.
Note: HRF-669FF/A series refrigerator compartment is a direct-cooling system.
Part4. Assembly figure
HRF-689FF/A
HRF-669FF/A
Refrigerator Model:HRF-669FF/A
5
/
Refrigerator Model:HRF-669FF/A
6
Refrigerator Model:HRF-669FF/A
7
Refrigerator Model:HRF-669FF/A
8
NO. In
exploded
view
Name of part Part No. Drawing No. QTY.
Unit
price(USD)
1 fridge foamed door assembly 0060816165
2 sharp conncetor 0060600081
3 down decorating strip 006021602660-006021602661.0000
4 block claw 006021700573-006021700572.0000
5 self attaching scres (ST3.9X13) 0064098005
6 freezer form door assembly 0060212579 1-0060212579 1.0000 42.41
7 bottom drawer assembly 00609270010 1.0000 6.79
8 top drawer assembly 00609270009 1.0000 4.07
9 freezer glass shelf assembly 00609350018 3.0000 4.42
10 bottom drawer right slide way assembly 00609380554 1.0000 0.74
11 top drawer right slide way assembly 00609380552 1.0000 0.77
12 bottom drawer left slide way assembly 00609380553 1.0000 0.77
13 glass shelf sildeway PS 476L 006021112922-0211 1292 6.0000 0.23
14 top drawer left slide way assembly 00609380551 1.0000 0.74
15 freezer lampshade PS 476L 006021112780-0211 1278 1.0000 2.18
16 screw 2Cr13 St3.9x7 0064098047 2.0000 0.03
17 soft gasket 006040501214-0405 0121 2.0000 0.04
18 anti-heat and glisten patch LF2-Y 1mm 006016000804-0160 0080 1.0000 0.15
19 lamp E27 00606040086 1.0000 1.89
20 screw cover PP 1700 006021603043-0216 0304 2.0000 0.01
21 bottom freezer air tower assembly 00609380589 1.0000 15.90
22 screw 2Cr13 St3.9x7 0064098047 2.0000 0.03
23 freezer air shutter assembly 00609380549 1.0000 3.05
Refrigerator Model:HRF-669FF/A
9
24 top freezer air tower assembly 00609380588 1.0000 1.02
25 screw 2Cr13 St3.9x7 0064098047 2.0000 0.03
26 freezer fan motor assembly 0060810869 1.0000
27 defrost waterspout assembly 006093804823-0938 0482 1.0000 3.48
28 evaporator assembly 00609320142 1.0000 73.57
29 right below hinge 0145 0672 1.0000
30 water pipe fixup nip 0060205753 4-0060205753 5.0000
31 cable clip PA 006021201654-0212 0165 1.0000 0.03
32 self attaching screw ST3.9X13( 0064098005 5.0000
33 screw 15 M6x16 0060802007 6.0000 0.02
34 bottom hinge Q215-A 006016100162-01610016 2.0000 0.93
35 gasket
0147 0404
2.0000
36 bottom shim PS 158K 006021113374-0211 1337 2.0000 0.09
37 adjustable foot assembly 006093805092-0938 0509 2.0000 0.28
38 screw 15 St5.5x13 0064082608 8.0000 0.01
39 universal wheel assembly 006093805263-0938 0526 2.0000 1.39
40 bottom dust block PVC 006021402834-0214 0283 3.0000 0.17
41 formed cabinet assembly 006090104870-0901 0487 1.0000 240.07
42 screw 15 St3.5x13 0064098005 6.0000 0.01
43 water dispensor valve 0060806084 1
44 cable of valve 00604 00035 1
45 enter water pipe 0060205757 3-0060205757 1
46 bundle nip of pipe 0060205754 4-0060205754 4
47 self attached scress ST3.9X13 0064098005 7
48 screw 15 St5.5x13 0064082608 6.0000 0.01
49 compressor bracket assembly 00609380586 1.0000 4.06
50
51 supply pipe of cold water 60205758 4-0060205758 1
52 keep silence sponge I I PU+ 006030800813-0308 0081 1.0000 0.60
53 connecting pipe of ice maker 0060205632 3-0060205632 1
54 evaporating dish PP 1700 006021605830-0216 0583 1.0000 1.97
55 keep silence sponge II II PU+ 006030800823-0308 0082 1.0000 0.70
56 screw 4098 005
57 keep silence sponge III III PU+ 006030800833-0308 0083 1.0000 0.98
58 connection tube for exhaust TU2M 006014301953-0143 0195 1.0000 1.33
59 eldow tighten screw 0060600085 1
60 elbow of enter water pipe 0060205633 3-0060205633 1
61 self attaching screw 0064098005 1.0000
62 condenser assembly 006050202280-0502 0228 1.0000 17.41
63 fan motor for disperse heat assembly 0060810870 1.0000
64 water-out pipe assembly 0938 0486
65 nameplate 006071313044-0713 1304 1.0000 0.65
66 screw 15 St3.5x13 0064098005 2.0000 0.01
67 fix slip 65Mn 006014506844-0145 0684 3.0000 0.05
68 screw 15 St3.5x13 0064098005 1.0000 0.01
Refrigerator Model:HRF-669FF/A
10
69 discharge tube TU2M 0067700001 4-7700 001 2.0000 0.21
70 keep silence sponge PU+ 006030800844-0308 0084 1.0000 1.20
71 keep silence sponge PU+ 006030800854-0308 0080 1.0000 2.61
72 compressor cover assembly 00609380590 1.0000 3.40
73 screw 15 St3.5x13 0064098005 1.0000 0.01
74 screw 15 St3.5x13 0064098005 1.0000 0.01
75 dryer fix slip 006014506854-0145 0685 1.0000 0.04
76 dryer 0060503010 1-0503 010 1.0000 1.03
77 bolt 15 0060804011 4.0000 0.02
78 spring washer Q115-A 0064240002 4.0000 0.00
79 shim Q215-A 0060147208 4-0147 208 4.0000 0.01
80 ruber shim 0060405099 4.0000 0.05
81 sleeve Q215-A 0060145577 4-0145 577 4.0000 0.03
82 compressor connection cable assembly 006061303443-0613 0344 1.0000 1.89
83 connection tube for suction TU2M 006014301944-0143 0194 1.0000 1.68
84 compressor LX110LAEM 0075010052 1.0000 280.00
85 compressor fixing accessories FGS 100HA0060803303 1.0000 0.41
86 earthing cable assembly 0060612006 4-0612 006 1.0000 0.13
87 screw TU2M M4x8 0060801042 1.0000 0.05
88 shim 0060806003 1.0000 0.02
89 power cable assembly 006061100983-0611 0098 1.0000 1.89
90 screw 15 St3.5x13 0064098005 4.0000 0.01
91 power panel 006060200903-0602 0090 1.0000 11.87
92 screw 15 St3.5x13 0064098005 2.0000 0.01
93 screw 15 St3.5x13 0064098005 2.0000 0.01
94 control panel cover PP 1700 006021113070-0211 1307 1.0000 3.05
95 control panel 0064000487 1.0000 217.00
96 control panel box PS 476L 006021602820-0216 0282 1.0000 2.18
97 lamp swith 0605 0061 1.0000
98 screw 15 M6x16 0060802007 4.0000 0.02
99 left top hinge box ABS 006021308092-0213 0809 1.0000 0.75
100 screw 15 St3.5x13 0064098005 6.0000 0.01
101 top hinge Q215-A 006014508782-01450878 2.0000 1.02
102 sensor cover ABS 006021308132-0213 0813 2.0000 0.06
103 right top hinge box ABS 006021308102-0213 0809 1.0000 0.75
104 echo /
105 echo /
106 echo /
107 fan motor assembly 0060812642 3.50
108 cover ABS 0060209781 1.0000 1.58
109 screw 2Cr13 St3.9x13 006080100874-0801 0087 3.0000 0.06
110 screw 2Cr13 St3.9x13 64098047 1.0000 0.06
111 box 0060202824 1.0000 0.80
112 support of shelves 00601470387 1.0000 0.08
113 screw 2Cr13 St3.9x7 006080100884-0801 0087 2.0000 0.03
114 cover 0064098047 6.0000 0.06
115 lamp support ( ) 60102790 1.0000 0.74
116 lamp (E14 25W) 00606040084 1.0000 0.50
Refrigerator Model:HRF-669FF/A
11
117 lamp holder 64000277 4-0801 0087 1.0000 0.06
118 screw 2Cr13 St3.9x7 00608010088 3.00 0.06
119 cold water jug 0060205763 1-0060205763 1
120 fixing stopper PP 1700 006021602893-0216 0289 6.0000 0.01
121 echo /
122 elbow tightern plastics screw I 0060600084 1 0.08
123 sleeve of water pipe 0060205750 3-0060205750 1.0000 0.11
124 seal ring of cold water pipe 0060300294 4-0060205768 1.0000 0.06
125 echo /
126 cantilevel shelf assembly 00609350017 3.0000 5.43
127 airproof bar PVC 006021402824-0214 0282 1.0000 0.52
128 the cable of freezer 606150129
129 screw 2Cr13 St3.9x13 006080100874-0801 0087 3.0000 0.06
130 screw 2Cr13 St3.9x13 006080100874-0801 0087 3.0000 0.06
131 egg box cover PS 158K 006021112801-0211 1280 1.0000 0.68
132 egg rack PS 158K 006021112812-0211 1281 1.0000 0.38
133 egg box PS 158K 006021112791-0211 1279 1.0000 1.90
134 top container left slide way assembly 00609380539 1.0000 0.39
135 top container right slide way assembly 00609380593 1.0000 0.39
136 bottom container right slide way assembly 00609380598 1.0000 0.39
137 slide of ice-crushed box 0060205614 3-0060205614 4.0000
138 top container glass shelf assembly 00609350016 1.0000 2.01
139 bottom container left slide way assembly 00609380540 1.0000 0.39
140 ice crushed motor box assembly 0060807764 1.0000
141 ellipse head screw 15M6*13 0064082803 1.0000
142 american type ice maker (GE 220V 0064000059 1.0000
143
screw
2Cr13 ST3.9x12 0060801 00874-0801 0087
1.00
144 top vegetable container, assembly 00609280029 1.0000 2.55
145 slide of ice-crushed box 0060205612 3-0060205612 2.0000
146 keep wet cover assembly 00609380548 1.0000 0.75
147 screw 0060801 00874-0801 0087 4.0000
148 bottom vegetable container assembly 00609280030 1.0000 2.96
149 ice-crushed box assembly 0060815848 0-0060815848 1.0000 8.96
149 ice crushed box assembly 60815848 1.0000
140 ice-crushed motor box assembly:0060807764
1 slide seat 0060205637 3-0060205637 1
2 spring column pin 1 0060600075 4-0060600075 1
3 slide block 0060205638 3-0060205638 1
4 connecting gulide 0060205640 4-0060205640 1
5 connecting cover 0060205639 3-0060205639 1
6 compressed spring 0060600074 4-0060600074 1
Refrigerator Model:HRF-669FF/A
12
7 spring column pin 2 0060600076 4-0060600075 1
8 electromagnetism valve / 0060806081 1
9 ice-crushed motor ( ) 0060806083 1
10 double side adhensive tape 1
11 eliminating noise foam block 0060300257 4-0060300257 1
12 double side adhensive tape 1
13 electromagnetism valve / 0060806081 1
14 ice-crushed box 0060205594 0-0060205594 1
15 stainless cross tray bolt 0060600091 2
16 outer side teeth block tray GB862.1--87.4 0060600092 1
17 dial fork 0060600077 3-0060600077 1
18 fitting screw 0060600078 2-0060600078 1
19 stainless cross tray bolt 0060600091 2
20 stainless cross tray bolt 0060600091 4
21 screw 2Cr13 ST3.9x12 0060801 0087 4-0801 0087 4
149 ice-crushed box assembly:0060815848
1 ice store box 60212580 0-0060212580 1
2 ice box seal ring 0060300270 4-0060300270 1
3 shaft cover of push shaft 0060205623 3-0060205623 1
4 ice push screw 0060108605 2-0060108605 1
5 wrest spring of dial pole 0060600067 3-0060600067 1
6 bracket of dial pole 0060103727 3-0060103727 1
7 bolt 2Cr13 ST3.9x12 0060801 00874-0801 0087 1
8 block patch of push ware 0060103725 3-0060103725 1
9 dial pole of push tongue 0060108606 2-0060108606 1
10 roller of push 0060205605 2-0060205605 1
11 scerw 2Cr13 ST3.9x12 0060801 00874-0801 0087 6
12 ice-crushed clapboard 0060103729 2-0060103729 1
13 No.1 circumrotate skates 1 0060103724 4-0060103724 1
14 No.1 skates tray 1 0060205607 4-0060205607 1
15 No.2 fixup skates 2 0060103721 4-0060103721 1
16 fitting block of skates 0060205609 4-0060205609 1
17 No.2 states tray 2 0060205608 4-0060205608 2
18 No.2 circumrotate skates 2 0060103723 4-0060103723 1
19 No.1 skates tray 1 0060205607 4-0060205607 1
20 fitting block of skates 1
21 No.2 states tray 2 0060205608 4-0060205608 2
22 spring column pin 5X50 0060600082 4-0060600075 1
23 No.3 circumrotate skates 3 0060103722 4-0060103722 1
Refrigerator Model:HRF-669FF/A
13
24 fitting screw ( ) 0060205604 4-0060205604 1
25 living stongue wrest srping 0060600072 3-0060600072 1
26 wrest spring of ice box 0060205606 3-0060205606 1
27 ice box seal ring 0060205616 1-0060205616 1
28 pin of living tongue 0060600083 4-0060600084 1
29 screw 2Cr13 M4*7 0060600091 3
30 round tray 0060600069 4-0060600069 1
31 spring tray 5 9 0060600071 300060600071 1
32 front lid of ice box 0060212581 1-0060212581 1
6 Freezer door assembly:0060816234
1 tray head self-attach scres 0060600073 4-0060600073 5
2 below decorated strip ( ) 0060205598 2-0060205598 1
3 front panel of ice dispensor 0060206198 0-0060205593 1
4 tray head self-attach scres 0060600073 4-0060600073 5
5 top decorated strip ( ) 0060205597 2-0060205597 1
6 control key 0060205601 3-0060205601 1
7 transparent display window 0060205600 3-0060205600 1
8 display panel assembly 0064000253 1
9 filler protection cover 0060206203 2-0060205620 1
10 protection cover tray of filler 0060300268 2-0060300268 1
11 lamp cover 0060205619 3-0060205619 1
12 main control box 0060206201 0-0060205618 1
13 screw 2Cr13 ST2.9*15 00604098047 4
14 jaggling switch 0064000361 1
15 switch plywood 0060205634 4-0060205634 1
16 screw 2Cr13 ST2.9*15 0060600096 1
17 rubber lip of touch cover 0060300325 3-0060300267 1
18 lip of touch cover 0060206202 3-0060205621 1
19 bracket of touch switch 0060205617 2-0060205617 1
20 electromagntism valve 0060806082 USEONG 1
21 screw 2Cr13 ST2.9*15 00604098047 3
22 filler lip switch 0064000270 2-0064000270 1
23 press patch of filler bracket ( ) 0060103988 4-0060103988 1
24 screw 2Cr13 ST2.9*15 00604098047 1
25 spring of filler bracket 0060600070 3-0060600070 1
26 filler cover 0060205622 3-0060205622 1
27 cover heater of filler mouth 06040068 12V/1.5W 1
28 spongge tray of filler 0060300254 4-0060300254 1
Refrigerator Model:HRF-669FF/A
14
29 seal ring of leaking mouth 0060300256 3-0060300256 1
30 water tray 0060206199 2-0060205599 1
31 lamp 0060604 0086 1
32 freezer little bottle bracket 0060205527 1-0060205527
33 edge of filler 0060205611 1-0060205611 1
34 freezer foaming door assembly 0060815849 0-0060815849 1
35 freezer explaining pad 0060506363
36 freezer lower bottle seat 00602111324
37 freezer bottle raining 00602111325
38 magentic seal assembly of freeze door 0060923 0094 1-0913 0112 1
39 hinge bushing 0060205761 1
3 REPLACEMENT PARTS LIST (WITH PRICE)
REPLACEMENT PARTS LIST (WITH PRICE)
Model:HRF-669FF/A
NO. In
exploded
view
Name of part Part No. Drawing No. QTY.
Unit
price(USD)
1 sharp conncetor 0060600081 1
9 freezer glass shelf assembly 00609350018 4.0000 4.42
15 freezer lampshade PS 476L 006021112780-0211 1278 1.0000 2.18
19 lamp E27 00606040086 1.0000 1.89
26 freezer fan motor assembly 0060810869 1.0000
43 water dispensor valve 0060806084 1
44 cable of valve 00604 00035 1 18.56
51 supply pipe of cold water 0060205758 4-0060205758 1
62 condenser assembly 006050202280-0502 0228 1.0000 17.41
63 fan motor for disperse heat assembly 0060810870 1.0000
82 compressor connection cable assembly 006061303443-0613 0344 1.0000 4.87
84 compressor LX110LAEM 0075010052 1.0000 280.00
85 compressor fixing accessories FGS 100HA0060803303 1.0000 0.41
86 earthing cable assembly 0060612006 4-0612 006 1.0000 0.13
89 power cable assembly 006061100983-0611 0098 1.0000 1.89
91 power panel 006060200903-0602 0090 1.0000 11.87
95 control panel 0064000487 1-0602 0089 1.0000 217.15
111 lamp E14 00606040084 2.0000 1.45
114 lamp E27 00606040086 1.0000 1.89
126 cantilevel shelf assembly 00609350017 3.0000 5.43
142 american type ice maker (GE 220V 0064000059 1
140 ice-crushed motor box assembly:0060807764
8 electromagnetism valve / 0060806081 1
Refrigerator Model:HRF-669FF/A
15
9 ice-crushed motor ( ) 0060806083 1
149 ice-crushed box assembly:0060807765
10 roller of push 0060205605 2-0060205605 1
24 fitting screw ( ) 0060205604 4-0060205604 1
26 wrest spring of ice box 0060205606 3-0060205606 1
27 ice box seal ring 0060205616 1-0060205616 1
6 Freezer door assembly:0060807531
7 transparent display window 0060205600 3-0060205600 1
8 display panel assembly 0064000253 1
11 lamp cover 0060205619 3-0060205619 1
12 main control box 0060207785 0-0060205618 1
14 jaggling switch 0064000361 1
20 electromagntism valve 0060806082 USEONG 1
22 filler lip switch 0064000270 2-0064000270 1
23 press patch of filler bracket ( ) 0060103988 4-0060103988 1
27 cover heater of filler mouth 06040068 12V/1.5W 1
31 lamp 0060604 0086 1
34 freezer foaming door assembly 60815849 0-0060815849 1
38 magentic seal assembly of freeze door 0060923 0094 1-0913 0112 1
39 hinge bushing 0060205761 1
Part6. Troubleshooting and Repair
6.1 Normal PhenomenaNot Troubles for Refrigerators
In a domestic refrigerator, there is not only a complicated electric control system, but also a
refrigerating system that is difficult to discern whether it is in a good working condition. Both the
systems are related and affect each other. If a certain part of a refrigerator works abnormally .Its
refrigerating efficiency will decrease, operation properties will become unstable, or even it cannot be
used normally for those serious cases.
Refrigerators are generally of larger volume, once troubles appear, to send them to a service department
is really a tough thing, if such is the case, the user will always be in suspense, sometimes, normal
phenomena will be erroneously regarded as troubles. Therefore, before we deal with the topics of
frequently occurring troubles of refrigerators and their remedies, we should firstly give a brief account
Refrigerator Model:HRF-669FF/A
16
of some normal phenomena which are not troubles .In case any one of such phenomena occurs, there is
no need to worry about it, and the user can use it at total ease.
1). When the compressor of a refrigerator has just stopped running, a rumbling sound can be heard from
inside its evaporator. This is a sound caused by the flowing of refrigerant in the evaporator tubing.
Because the pressure difference is still greater after the compressor has just stopped running, the
refrigerant will flow for a certain time; therefore, this sound is a normal phenomenon.
2). A click sound can often be heard from the refrigerator. This is a normal sound produced by the pull-
in or release of the armature of a current deadweight start relay when starting the compressor .The
compressor motor will produce a slight and uniform sound while it is running. This sound is not easy to
be heard in the daytime, but of course it can be heard distinctly at night.
3).The compressor consists of an electric motor and a compressing apparatus .During its normal
operation ,the motors stator core and windings will rise to a temperature in the range of 100 ~110
,and the temperature of the piston and cylinder of the compressing mechanism can also reach as
above 100 due to the heat produced when compressing refrigerant .Most of the heat radiates to the air
through the compressor casing ,therefore ,its casing is generally at a temperature between 85 ~90 ,it
is very hot ,particularly in summer when the ambient temperature is higher .All these are normal
phenomena .
4). For the forced air cooling refrigerator, a kind of irregular crack sound can be often heard when the
compressor is running for a certain period of time or has just stopped its running. The stress relief due to
expansion and contraction causes this sound when temperature changes, and will not affect the normal
application of refrigerator.
6.2 Common Troubles in Refrigerators and Their Remedies
Causes for troubles occurring in refrigerators are closely related to the quality of components and
workmanship in assembling by manufacturers as whether refrigerators are properly used and
maintained .The parameters generally used to express the working conditions of a refrigerator include
the temperature inside the refrigerator, operation rate, electric power consumption, noise level, and
other functional indexes .If any one of these parameters is beyond its permissible range, this indicates
that there is a fault or trouble in the refrigerator.
During the whole service life of a refrigerator, the probability of troubles occurring within a union time
is called its failure rate. Making a comparison between the control circuit system of a refrigerator and its
refrigerating system, we can find that the failure rate of the former is higher, and that of the thermostat
is the highest. In troubleshooting, the first thing you must do is to determine where the trouble comes
from--- the control system or the refrigerating system. There is general no trouble indicating instrument
Refrigerator Model:HRF-669FF/A
17
mounted on the domestic refrigerator, locations and natures of troubles should be determined according
to their respective features, therefore, experience in servicing is very important to troubleshooting.
Service technicians with rich experience can correctly locate them and take reasonable remedy
measures based on their comprehensive analysis of trouble characteristics as well as operating
conditions for various kinds of refrigerators.
Three Essentials for Checkup
1) Look
a) Check the tubing of refrigerating system for cracks and various welding points for leaks; if
leakage occurs, an oil stain can be seen definitely .
b) Check the suction and exhaust pressure values (high pressure and low pressure) of compressor
to see whether they are normal.
c) Check the conditions of frost attached to its evaporator and gas return tube .It is abnormal if
frost has formed on part of the evaporator or there is no frost attached to it. (This criterion is not
applicable to the evaporator of refrigerator compartment.)
d) Pay attention to the speed of temperature drop inside both the refrigerator compartment and
freezer compartment .It is abnormal if the speed of temperature drop is obviously slower than the
corresponding normal speed.
e) Check the environment to see whether it is suitable for placing a refrigerator.
f) Check refrigerator door seal, case, and table surface and heat insulation layer.
2) Listen
a) Listen to the noises produced when the compressor is running
Hums from a fully enclosed aggregate unit is the sound caused by overload indicating that the motor
cannot be started normally, meanwhile, a clattering sound can be heard from inside the start relay,
which is produced because the start contacts cannot be released normally whistling sound is caused by
the high pressure gas flowing out of the crack of the pressure tube inside the compressor, and clucks are
the sound of striking after the suspended spring inside the compressor has broken.
During the normal operation of compressor, a slight and uniform hum sound due to undulation of
electric current can be heard generally, this is a normal phenomenon. However, if it sounds like tong,
tong, i.e., an impact sound inside the compressor, this means that a large quantity of wet vapor of
refrigerant or refrigerating oil has come into the compressor cylinder; if it sounds like dang, dang, a
striking sound of metal parts inside the compressor ,this means that some moving parts have loosened
(note to differentiate this sound from those formed during starting or stopping the compressor).
b) Listen to the sound caused by the flowing of gas in the evaporator
Open the refrigerator door while the compressor is in operation , incline your ear and listen attentively
the gas flow sound inside the evaporator .If it sounds like gentle whistling accompanied by a sound
Refrigerator Model:HRF-669FF/A
18
similar to water flowing ,this is the sound produced by the normal circulation of refrigerant within the
evaporator .In case only the gas flowing sound can be heard and there is no water flowing sound ,this
indicates that the refrigerant has already percolated .If neither the flowing sound nor the gas sounds
from the evaporator can be heard ,this means that the filter or capillary has been clogged .
3) Touch and Feel
a) Feel the compressor when running ,its temperature should be generally less than 90 in the
normal state (it may exceed 90 in case of running for a longer period of time ).
b) After the compressor has operated normally for 5~10 minutes, touch and feel the condenser,
the temperature of its upper part should be higher than that of its lower part (or its right part is hotter
than its left part, depending on the type of condenser coil), this indicates that the refrigerant is
circulating. If the condenser is not hot, this means the leakage of refrigerant, In case the condenser
radiates heat for only several minutes and then cools down, this means that the filter and capillary have
been clogged. As for the forced air cooling condenser, hot air will be blown out of it; this means that the
system is out of order.
c) Feel the filters temperature. During the normal operation of refrigerating system, the
temperature on the filters surface should be a little higher than the ambient temperature; if you touch it
with your hand, you will have a sense of slight heat. In case dew condensation appears due to the fact
that its temperature is obviously lower than the ambient temperature, this means that most meshes of its
screen has been clogged, resulting in an obstructed flowing of refrigerant, thus causing a drop in
temperature due to throttling.
d) Feel the temperature of exhaust gas from the refrigerating system .the exhaust gas should be
very hot and this is the normal working state. For those refrigerator with enclosed type of compressor
refrigerating system, no frost or dew drop will from on the gas suction tube, otherwise, there is
something wrong in the system (Frosting and dew condensation may appear for a very short time period
when just starting the machine, this is a normal phenomenon).
Because a refrigerator is a combination of several components, they are related and have influence on
each other .In case an abnormal phenomenon has been found through the above-mentioned checkups,
you need not to make a hasty conclusion based on only one abnormal phenomenon .It is advisable to
find out two or more abnormal phenomenon, or conduct troubleshooting comprehensively with the aid
of instruments or other ways, because several kinds of troubles may share a common abnormal
phenomenon, and two or more abnormal phenomena may occur simultaneously due to a certain
trouble .With this method , you can reject some suspicious troubles and finally make a correct
judgment .
6.3 Analysis of Troubles and Troubleshooting
Refrigerator Model:HRF-669FF/A
19
A. Poor Refrigerating Effect
The so-called poor refrigerating effect refers to the fact that the refrigerator can operate and
refrigerator normally, but the temperature in the refrigerator cannot drop to the prescribed value under
the stipulated working conditions. In view of there are many causes for this phenomenon, we are going
to discuss and analyze it in the following 7 aspects:
1) Leakage of refrigerant
Analysis of Trouble
The leakage of refrigerant in the system will result in an insufficient refrigerating capacity, the resulting
phenomena are its lower gas suction pressure and exhaust pressure as well as higher exhaust gas
temperature. The exhaust tube feels rather hot, and a continuous gas flowing sound louder than usual
can be heard at the outlet of the capillary, and no frost or a smaller quantity of loose frost appears on the
evaporator. After shut down, the balance pressure in the system is usually lower than the saturation
pressure corresponding to the same ambient temperature.
Remedy
In case there is leakage of refrigerant from the system, do not hurry to recharge it with refrigerant,
manage to find out leak points immediately, and make a note of from where it leaks ---welding points
and parts. After having them repaired, recharge refrigerant.
There are so many joints and sealed surfaces in a refrigerator, accordingly, quite a lot potential leak
points do exist in the system. In troubleshooting, pay attention to those parts that are liable to leak,
check main connection points for oil seepage and tubing for cracks. If there is no severer leak point,
charge the system with nitrogen and detect leak points with the commonly adopted method, repair them,
evacuate, charge the system with refrigerant, and then turn on the refrigerator to make a test run.
2) Too much refrigerant charged into the system
Analysis of Trouble
a) In case the amount of refrigerant charged into the system exceeds its nominal capacity, the
superfluous refrigerant will of course take some space of the evaporator, thus reducing its heat-
dissipation area and hence the refrigerating efficiency of the system. The abnormal phenomena caused
by this reason are as follows: the gas suction and exhaust pressures are generally higher than their
respective normal values, the temperature of its condenser is higher and the electric current of the
compressor rises, loose frost forms on the evaporator, the refrigerator temperature drops slowly, and
frost appears on the gas return tube .
b) In case excessive refrigerant has been charged, the liquid refrigerant that can not evaporates in
the evaporator will return to the compressor, and thus a phenomenon of liquid striking will occur. The
liquid refrigerant evaporates and effervesces as soon as it flows into the refrigerating oil at the bottom
Refrigerator Model:HRF-669FF/A
20
of compressor .If the condition is severe, foams will fill all over inside the compressor housing and be
sucked by the piston, causing damage to the components of compressor.
Remedy
According to the operating procedures, it is mandatory to turn the machine off, and several minutes later,
open the refrigerant charging tube and let the refrigerant escape from it, replace the dry filter, recharge
refrigerant after evacuating, and then seal the charging port.
3) There is air left in the refrigerating system
Analysis of Trouble
Residual air in the refrigerating system will reduce its refrigerating efficiency .The prominent
phenomena are the increase in its gas suction and exhaust pressures (however, the gas exhaust pressure
will not exceed its rated value), obvious increase in temperature in the segment from the compressor
outlet to the condenser inlet. Because there is air in the system, both the gas exhaust pressure and
temperature will rise, and moreover, the gas flowing sound is intermittent and obviously louder.
Remedy
After shut down for several minutes, open the tubing, evacuate it and then recharge the system with
refrigerant.
4) Low efficiency of compressor
Analysis of Trouble
Low efficiency of a refrigerating compressor refers to the actual reduction of gas discharge capacity,
and hence the corresponding reduction of refrigerating capacity, under the condition that the refrigerant
in the system is unchanged. This phenomenon occurs mostly when the compressor has been used for
quite a long time, its moving parts have worn to a considerable degree, fit clearance between various
parts have increased and sealing property of its gas valve has deteriorated, resulting in an decrease in its
actual gas discharge capacity.
Methods of Judgment
Measure the high and low pressures with pressure gauges to see whether they are normal. If an
abnormal sound comes from the compressor or the temperature of its causing is too high, cut the
discharge port open and operate the compressor, feel it if there is pressure at the discharge port with
your finger (For a normal compressor, its discharge port is difficult to be blocked with your finger if
you just apply a little effort).
5) Refrigerating oil left in evaporator tubing
Refrigerator Model:HRF-669FF/A
21
Analysis of Trouble
During the process of refrigerating cycles, a little refrigerating oil may remain in the evaporator tubing,
and after a longer time of operation, if there is considerable refrigerating oil left in the evaporator, the
heat conduction effect will be severely affected, thus causing a poor refrigerating effect.
Remedy
It is quite difficult to determine whether this trouble is caused by the refrigerating oil left in the
evaporator tubing, because this kind of phenomenon and other several trouble are tends to be confused.
Generally speaking, you can make a judgment based on the frost formed on the evaporator. If the frost
does not cover the evaporator, and moreover, it is loosely formed, you can make a judgment that the
deterioration of refrigerating effect is due to the accumulation of refrigerating oil left in the evaporator
tubing in case no other troubles have been found. To clear off refrigerating oil left in the evaporator,
dismantle the evaporator, purge it thoroughly and then dry it. In case it is difficult to dismantle it,
charge refrigerant from the evaporator inlet to wash it several times, then purge and dry it with nitrogen.
6) Flowing obstructed in refrigerating system
Analysis of Trouble
Because the refrigerating system was originally not purged thoroughly, some of the filter screen meshes
have been clogged by dirt accumulated in the filter after using it for a certain time of period, thus
resulting in a decrease in flow rate, and hence a poorer refrigerating effect.
The abnormal phenomena caused by this kind of slight clogging in the system are as follows: the gas
discharge pressure is lower, the temperature of discharged gas drops down, the position clogged has a
temperature lower than that in normal conditions, and for a severe clogging, even dew condensation as
frosting may appear.
Remedy
Purge the tubing, and after replacing the dry filter with a new one or clearing it thoroughly, recharge the
system with refrigerant and seal the charging port.
B. No Refrigerating
The phenomenon that the compressor runs normally, but no frost (or only a little frost) appears on the
evaporator, and the refrigerator temperature does not drop down is called no refrigerating. There are
many causes for this trouble and it is relatively complicated, too. In servicing, special attention to
finding direct causes for this phenomenon. Three main potential causes for this trouble are analyzed
below:
1) All refrigerant in the system has leaked out
Refrigerator Model:HRF-669FF/A
22
Analysis of Trouble
Leak points in the refrigerating system have not been found and repaired timely, thus resulting in the
total escape of refrigerant. There are two kinds of leakage: I) slow leakage for instance, when we want
to use a refrigerator that has been put out of quite a long time, we find the leakage of refrigerant, or in
the course of its operation, we have found that the refrigerator is gradually becoming not so cold and
finally no refrigerating cab be achieved; ii) fast leakage in that case, all the refrigerant will escape
swiftly due to abrupt rupture of systemtubing.
Symptoms of total leakage of refrigerant are mainly as follows: the compressor can be started easily (if
there is no damage to the compressor parts) and its operating current becomes low, its gas suction
pressure is high and discharge pressure is lower, the gas discharge tube feels rather cold, no sound of
gas eruption from the liquid in the evaporator can be heard, and no will gush out of the process tube if
you cut it open after shutdown.
Remedy
Check the whole machine, particularly those locations, which are liable to leak. After leak points have
been found, repair them or replace them with new parts according to specific circumstances, then
evacuate the system and finally charge refrigerant.
2) Refrigerating system has been clogged
a) Clogged with Ice
Analysis of Trouble
The dryness treatment for the major parts in the refrigerating system has been performed improperly,
the effect of air purging for the whole system is not good ,or the water content in the refrigerant is out of
standard ,all these will cause the expansion valve to be clogged with ice .The symptom for this trouble
are as follows :the refrigerator sometimes can refrigerate and sometimes cannot :the refrigerator
compartment works normally at the beginning ,but after working for a certain period of time ,frosting
begins at the clogged position ,evaporation temperature reaches below 0 , water will accumulate at the
narrow part of the capillary and clog it gradually ,then frost begins to melt at the evaporator ,no gas
flowing sound can be heard ,and the gas suction pressure assumes a state of vacuum .Note that these
phenomena will appear intermittently ; sometimes ,the refrigerator works well ,and sometimes not
well .In order to determine whether it is clogged with ice ,heat the suspicious points with hot water to
make ice melt ,and after a while if a gas flowing sound resulting from an abrupt gush is heard and the
gas suction pressure rises as well ,it can be confirmed that the trouble is caused by ice clogging .
Remedy
If there is too much moisture in the refrigerating system, it is advisable to release the refrigerant, purge
the tubing with nitrogen, and then charge the system with the filtered refrigerant. However, the
commonly adopted method is to connect a filter with moisture absorbers (such as silica-gel, anhydrous
Refrigerator Model:HRF-669FF/A
23
calcium chloride) to the refrigerating system so as to filter out the moisture from the system, then
replace the filter, evacuate it again and finally charge the system with refrigerant.
b) Clogged with dirt in capillary
Analysis of Trouble
The capillary inlet is a place where coarse-grained dirt or refrigerant oil in the system will tend to settle
down and clog it. In case considerable dirt accumulates there, the whole filter screen may be blocked
totally, making the refrigerant unable to go through. Clogging with dirt exhibits the same symptoms as
that with ice, namely, higher gas suction pressure, lower temperature of discharged gas, and no gas
flowing sound from the evaporator. The difference between the both is as follows: if the clogging is
caused by dirt, tapping the suspicious clogged point (generally in the capillary or the connection joint of
the filter) may cause the refrigerant to flow through partially, resulting in some corresponding change,
whereas in that case if you heat it with a hot towel, no reaction will happen, no flowing sound can be
heard, moreover, there is no periodic change. After rejecting the possibility of ice clogging, it can be
generally considered as the clogging due to dirt.
Remedy
Dismantle the system, remove the dry filter from it, purge the tubing with nitrogen, install a new filter,
then evacuate it and finally charge it with refrigerant.
C) Clogging in filter
Analysis of Trouble
Total clogging of a filter is rarely to occur. The paste-like matter formed from the substances filled into
the system mostly causes this trouble or other dust after the refrigerator has been used for a longer time,
or by the dirt accumulated gradually inside the filter. Sometimes, tapping the filter nay cause a passage
for flowing, Touching it with your hand, you will feel that it is cooler compared with its temperature in
the normal state.
Remedy
The same as described in the capillary clogging with dirt.
3) Troubles of Compressor
a) Breakage of gas suction and discharge valve blocks
Analysis of Trouble
Refrigerator Model:HRF-669FF/A
24
The compressor works by means of the opening and closing of gas suction valve and discharge valve to
suck and discharge the refrigerant. If the valve block is broken, the refrigerant can not be discharged,
and hence no refrigerating can be achieved.
Method for making judgement
It is quite difficult to differentiate this trouble from others because they often have similar symptoms. In
repairing, firstly, hear attentively if there is some abnormal sound coming from the compressor
(sometimes, the broken pieces of valve block may strike against the cylinder), and feel the compressor
casing with your hand to ascertain whether it is too hot, this is also helpful to the troubleshooting;
secondly, measure the pressures at the high and low pressure ports of the compressor with pressure
gauges, if the gas suction valve block is broken, the suction pressure gauge pointer will swing violently
and the suction pressure is very high, whereas when the gas discharge valve block is broken , the
discharge pressure gauge pointer will swing drastically and the discharge pressure is very high. In the
both cases, stop the compressor at once, and if technique is available, open the cylinder cover and check
up the valve block, repair it, or replace it with a new one,
C. Sudden stop of Compressor during Its Running
The cause of sudden stop of a compressor during its running is mostly that the gas suction pressure
and/or discharge pressure exceed their respective prescribed ranges, thus making a pressure-operated
protective relay shut off the power to the compressor and stop it. In the following we discuss mainly the
reasons for causing excessively high gas discharge pressure and low suction pressure.
1) Stoppage due to excessively high gas discharge pressure
A) Too much refrigerant charged into the system
Analysis of Trouble
The phenomenon, such as loose frosting and poor refrigerating effect, may occur if excessive refrigerant
has been charged into the system. Superfluous refrigerant will occupy a certain space of the evaporator,
thus reduce its heat dissipating area, and the phenomenon of liquid striking may occur, too.
Meanwhile, dew or frost condensation may occur on the gas return tube, and the gas discharge pressure
will obviously rise, when it reaches the threshold value, the protective relay will actuate and shut off the
power supply to the compressor.
Remedy
Open the tubing, re-evacuate and then charge the system with a proper quantity of refrigerant.
b) Air left in the system
Refrigerator Model:HRF-669FF/A
25
Analysis of Trouble
The residual air in the system will circulate together with the refrigerant in the system. The major
symptoms caused by this residual air is higher gas discharge pressure, higher discharged gas
temperature (the gas discharge tubing is considerably hot when you feel it with your hand), and poorer
refrigerating effect. Furthermore, the gas discharge pressure will exceed its normal value when the
compressor has run for a period not too long, thus making the protective relay actuate and bring to a
stoppage.
Remedy
Check up how the air has been left in the refrigerating system. Generally, there are two possibilities:
one is that the air has been sucked into the system when repairing due to carelessness, or it has not been
purged out totally when evacuating the system; the other is that there are leak points at the low pressure
end of the refrigerating system. Leak points appear mostly in those low temperature parts or assemblies,
because the evaporation temperature is lower for such low temperature devices, especially at the low
pressure end, it is easier for the air goes into the system. Once it has been ascertained that air does exist
in the system, you have to open the tubing, re-evacuate it and then charge it with refrigerant.
2) Stoppage due to electric troubles
a) Thermostat is out of control
Analysis of Trouble
In case the thermostat does not work in its good order or its temperature sensor has not been installed
properly, frequent stoppage is also likely to occur.
Remedy
Try to adjust the temperature sensors position until the compressor can be started and stopped normally.
If this cannot be achieved, and the stoppage still occurs repeatedly, it is most likely that the mechanical
parts or contacts are out of order, disassemble the thermostat, make a thorough checkup and repair it.
b) Overload of electric motor
Analysis of Trouble
Probably, too many things have been put into the refrigerator, and hence the thermal load exceeds its
refrigerating capacity; or in case the power supply voltage drops considerably, the current flowing
through the motor will increase drastically making the thermal protector actuate and the fuse blown, and
hence the motor stops running. If the motor is still running continuously in such a case, its windings will
be burned out.
Refrigerator Model:HRF-669FF/A
26
Remedy
Reduce the thermal load; pay attention to the variation in voltage of the power supply.
c) Abnormal thermal protection
Analysis of Trouble
The compressor current is within its normal range, but the thermal protector actuates repeatedly.
Remedy
Replace the thermal protector with a new one.
3) Sudden stoppage due to other causes
Normal Stoppage
A thermostat generally controls start and stop of the compressor. When the temperature in the
refrigerator reaches its desired value, the thermostat will shut down the compressor automatically.
Never take this normal operation as a trouble, care should be taken to differentiate it from other real
troubles in servicing.
D. Compressor won 't start
In case the compressor cannot be started, you must find out the origins of this trouble through checkup
step by step, because probably there are many causes, including those electrical and mechanical.
1) Inspect the power supply to see whether it is connected to the compressor circuit.
Analysis of Trouble
In case the compressor cannot be started, this will generally exhibit in the power supply circuit, for
instance, power failure, poor contact of switch, and blown fuse. Make a comprehensive analysis of
these phenomena, find out its real cause and take correct measures to remove this trouble.
Remedy
a) Check the input power circuit to see whether where is voltage of the power supplies, namely, the
circuit which is connected to the knife switch. This can be determined with an avometer or a test pencil.
If a blown fuse is found, ascertain and remove its cause, then replace it with a new one of the same
specifications.
b) Check the compressor accessories, including its thermal protector and relay. In case the thermal
protector is damaged, the compressor cannot be powered on. If the relay is out of order, the motor will
not run and hum sound can be heard from it after the compressor is turned on, in that case, shut it down
immediately, otherwise, the motor windings will be burned out in case this condition lasts longer.
Refrigerator Model:HRF-669FF/A
27
c) Check the relay contacts and plugs to see if they are perfect and work reliably. Poor contact may
cause the motor not running or humming.
2) Check the circuit voltage to see whether it is normal.
Analysis of trouble
If the circuit voltage is obviously lower than its rated value, it will be difficult to start the motor, and a
hum sound can be heard from it.
Remedy
Measures the voltage with a voltmeter, if it is really too low, give directions to the user for buying a
stabilizer so as to step up the voltage, thus normal operation can be achieved.
3) Check the thermal relay to see whether its contacts are closed.
Analysis of Trouble
The contacts of thermal relay sometimes may be open due to the leakage of temperature sensing agent
from the temperature sensor.
Remedy
Remove the relay cover to check up its contacts, if they are open, this means that the original setting is
not properly set or temperature sensing agent has leaked out of the temperature sensor. Try to turn the
adjusting stem of this value in the direction of the lower temperature graduation, then check the contacts
to see whether they are closed. If they are still not closed, dismantle the temperature sensing disc and
then immerse it into warm water to see whether the contacts actuate, if not, it can be preliminarily
determine that temperature sensing agent has leaked out, and it must be replaced with a new thermostat.
4) Motor troubles and other electric faults
a) Motor windings have been burned or short-circuited between turns
Analysis of Trouble
When motor windings have been burned or short-circuited between turns, the fuse will be blown
repeatedly, and the blowout occurs particularly at the instant when you close the knife switch.
Remedy
Check the terminals and the outer casing to see whether they are short-circuited, and measure the
resistance of each phase with an avometer. If short circuit occurs or the resistance of a certain phase is
low, this means that short circuit does exist in the windings and/or between turns, and insulation layers
have been burned or deteriorated. A megametre can be used in this inspection, too. If the insulation
Refrigerator Model:HRF-669FF/A
28
resistance is lower than 2 M, this means that the insulation layer is already breakdown. If the motor
has been burned, repair it or replaced it with a new one.
b) Fault of control relay
Analysis of Trouble
Overheat, burnout or wear of control relay contacts may occur generally. All these will cause poor
contact in electricity.
Remedy
Dismantle it to repair, or replace it with a new one.
c) Poor electric contractor in thermostat
Analysis of Trouble
Burnout of contractor and leakage of temperature sensing agent may occur generally.
Remedy
Replace the old with a new one.
d) Check the terminals for loose connection and electric circuits for other abnormal phenomena.
5) Mechanical faults of compressor
a) Seizing of shaft
This phenomenon is caused mostly by poor lubrication, such as insufficient quantity of lubricant,
clogging in the lubricant oil line, or intermittent lubricant oil supply. Dirt and other impurities in the
lubricant oil will increase its viscosity and cause the shaft to be seized. Copper plating may also result
in seizing of shaft.
b) Seizing of piston
This is caused by too small fit clearance between the piston and cylinder or expansion due to heat.
Judgement of seizing shaft and piston: After the refrigerator has been powered on, the compressor will
not start and run, but a slight hum sound can be heard, and several seconds later, thermal protective
relay will actuate and make the contacts open; this process will occur repeatedly, but the compressor
cannot be started.
Refrigerator Model:HRF-669FF/A
29
E. Compressor wont stop
Sometimes, the compressor will run continuously (for several hours or run without end), If the food
placed in the refrigerator is not too much, there may be the following two situations: I) the refrigerator
very low, this means that the control system is probably out of order; ii) the control system works
normally, and there are troubles in the refrigerating system or other parts.
1) Temperature is set improperly
a) The temperature control knob is set to the coldest position. This position is to be used for fast
freezing or continuous running, its temperature for power off is too low, therefore, the compressor
wont stop and the temperature in the refrigerator becomes lower and lowers.
b) Inspection method: check the temperature control knob to see whether it is set in the position
coldest.
2) Thermostat is malfunctioning and makes the compressor running continuously
Analysis of Trouble
When the thermostat doesnt work normally, it will make the compressor run continuously, and hence
very low temperature will be achieved in the refrigerator. The fault is generally due to the fact that the
contacts of the thermostat cannot be released.
Remedy
Dismantle the thermostat and make a through checkup, if it is totally out of functioning, replace it with
a new one.
3) evaporation temperature is too high in refrigerating system, resulting in lower refrigerating
capacity and hence continuous running of compressor
Analysis of Trouble
Leakage of refrigerant and clogging in a refrigerating system will directly affect its refrigerating
capacity. Due to the reduction in its refrigerating capacity, the refrigerator temperature cannot reach its
rated value, the thermostat wont work, and thus the compressor runs continuously. When the
evaporation temperature in the system is too high, the temperature-sensing agent in the temperature
sensor is also hotter, therefore, the thermostat is unable to cut off the power supply to the compressor
and stop it.
Remedy
If it has been found that the refrigerant in the system is insufficient in quantity, recharge it with
refrigerant. In case clogging occurs, disassemble the part where it is blocked. If the evaporation
temperature is too high, settle this problem with an appropriate quantity of refrigerant.
Refrigerator Model:HRF-669FF/A
30
4) No stoppage of compressor due to damaged heat-insulation layer inside case body and/or door
seal
Analysis of Trouble
When the heat-insulation layer inside the case body deteriorates or the door seal is not closely touches
the doorframe, the temperature in the refrigerator will rise and makes the compressor running
continuously.
Remedy
Check the heat-insulation layer for its damaged parts; repair it to improve its heat-insulation property. If
the door has deformed or the door seal is not tightly sealed against the case body, repair them,
respectively.
5) Too much food is placed in the refrigerator, or is placed too densely, resulting in poor ventilation
or poor conditions for temperature sensing, and hence no stoppage of the compressor.
6) Too high ambient temperature, poorer ventilation and heat dissipation makes the compressor
running without stop.
F. Electric leakage of refrigerator
1) Slight electric leakage
Electric insulation has deteriorated due to being affected with damp, thus resulting in slight electric
leakage.
2) Serious electric leakage
Refrigerator case has become live due to faults occurred in some electric devices or the erroneous
wiring in installing power cord plug or outlet by the user. This is very dangerous.
3) Electric leakage test
a) Slight electric leakage
A tingle sense will be experienced as soon as you touch the metal parts of the refrigerator with your
hand. When you test them with a test pencil, its neon lamp will come on .In that case, the first thing you
need to do is to determine whether the grounding is perfect .If the grounding is no problem, turn off the
refrigerator immediately, then check the insulation of electric circuits with an avometer.
b) Serious electric leakage
Refrigerator Model:HRF-669FF/A
31
Never touch the case body of the refrigerator, its door handle or other metal parts with your hand. Test
the refrigerator with a test pencil, it will
light up intensively ;measure the resistance between the power cord plug and the case body with an
avometer ,the reading will be zero (0); in the worst case ,the fuse will be blown .Check the 3-prong
outlet to see whether the live wire and the null line are inversely connected ,this makes the ground
protection lead-out from the power cord plug being connected to the live wire .Another possibility is
that the live wire and null line of the outdoor power supply circuit have been inversely connected
accordingly ,this makes the null line become a live wire .
G. Stronger vibration and loader noise
1) Refrigerator placed improperly
a) Uneven ground
Uneven ground will cause the refrigerator to be placed unsteadily, causing stronger vibration and noise
during its operation.
b) Leveling screws not properly adjusted
If the leveling screws on refrigerator legs have not been adjusted properly, vibration and noise will still
occur even if the refrigerator has been placed on a level ground.
2) Abnormal noise from compressor
Three suspended spring inside the compressor case are out of balance, and strike against the case,
moreover, the wear of compressor parts may cause noise sometimes.
3) Resonance of tubing and loosening of parts
Improper and compact laying of tubes or the loosening of parts may cause vibration and noise.
4 Large noise of the fan
a)The fan motor is loose;
b)Noise is produced by normal operation of the fan.
c)The impellers are not tightly fixed or eccentrically assembled.
Remedy:
For reason a): Fasten the fan motor.
For reason b) or c): Replace the fan motor or impellers.
5)Inspection method
Refrigerator Model:HRF-669FF/A
32
To find the sources of noise, press the vibration spot with your hand while the refrigerator is in
operation and listen attentively whether the vibration becomes weaker or vanishes. If the refrigerator
has not been levelly placed, put a level meter on its top table and adjust the leveling screws on its legs.
In case noise occurs from the compressor, strike different locations on the side surface of its case using
a rubber hammer or hand hammer with a wood block in-between so as to determine whether the
suspended springs are out of balance or being seized.
Part 7. Replacement Parts List
REPLACEMENT PARTS LIST (WITH PRICE)
NO. In
exploded
view
Name of part Part No. Drawing No. QTY.
Unit
price(USD)
1 sharp conncetor 0060600081 1
9freezer glass shelf assembly 00609350018 4.0000 4.42
15freezer lampshade PS 476L 00602111278 0-0211 1278 1.0000 2.18
19lamp E27 00606040086 1.0000 1.89
26freezer fan motor assembly 0060810869 1.0000
43 water dispensor valve 0060806084 1
44 cable of valve 00604 00035 1 18.56
51 supply pipe of cold water 0060205758
4-
0060205758 1
62condenser assembly 00605020228 0-0502 0228 1.0000 17.41
63
fan motor for disperse heat
assembly 0060810870 1.0000
82
compressor connection cable
assembly 00606130344 3-0613 0344 1.0000 4.87
84compressor LX110LAEM0075010052 1.0000 280.00
85compressor fixing accessories
FGS
100HA 0060803303 1.0000 0.41
86earthing cable assembly 0060612006 4-0612 006 1.0000 0.13
89power cable assembly 00606110098 3-0611 0098 1.0000 1.89
91power panel 00606020090 3-0602 0090 1.0000 11.87
95control panel 0064000487 1-0602 0089 1.0000 217.15
111lamp E14 00606040084 2.0000 1.45
114lamp E27 00606040086 1.0000 1.89
126cantilevel shelf assembly 00609350017 3.0000 5.43
142 american type ice maker (GE 220V 0064000059 1
140 ice-crushed motor box assembly:0060807764
8 electromagnetism valve / 0060806081 1
9 ice-crushed motor ( ) 0060806083 1
Refrigerator Model:HRF-669FF/A
33
149 ice-crushed box assembly:0060807765
10 roller of push 0060205605
2-
0060205605 1
24 fitting screw ( ) 0060205604
4-
0060205604 1
26 wrest spring of ice box 0060205606
3-
0060205606 1
27 ice box seal ring 0060205616
1-
0060205616 1
33 overturn lid of ice box 0060205595
0-
0060205595 1
6 Freezer door assembly:0060807531
7 transparent display window 0060205600
3-
0060205600 1
8 display panel assembly 0064000253 1
11 lamp cover 0060205619
3-
0060205619 1
12 main control box 0060207785
0-
0060205618 1
14 jaggling switch 0064000361 1
20 electromagntism valve 0060806082 USEONG 1
22 filler lip switch 0064000270
2-
0064000270 1
23 press patch of filler bracket ( ) 0060103988
4-
0060103988 1
27 cover heater of filler mouth 06040068
12V/1.5W
1
31 lamp
0060604
0086 1
34 freezer foaming door assembly 0060807544
0-
0060807544 1
38
magentic seal assembly of freeze
door 0060923 0094 1-0913 0112 1
39 hinge bushing 0060205761 1
1 fridge door assembly:0060805928
2 bar inner glue strip assembly 0060805985
2-
0060805985 1
3 foam panel assembly of mini bar 0060805965
1-
0060805965 1
10 stay bar assembly 0060806037
3-
0060806037 2
14 left hinge assembly 0060806065
3-
0060806065 1
15 stainless hinge press pad 2/1Cr18Ni9 0060103273
4-
0060103273 2
Refrigerator Model:HRF-669FF/A
34
17 right hinge assembly 0060806066
3-
0060806065 1
35 seal lip cover of mini bar 0060206885
0-
0060204531 1
36 seal lip of mini bar PS168No 0060204530
0-
0060204530 1