You are on page 1of 6

Industrial Electronic

For A&I and Sales Engineers


CSARL Industrial Electronic-A&I / February 2001
FLS / FTS
-Full load and full torque setting
-Change only based on dyno test after engine repair and/
or engine overhaul.
-Max. possible influencing range > +/ - 10 % of power
-Programmable range -128 - +127
-Emission laws do not allow power adjustments based on
external conditions (fuel / altitude / etc)
-USE TEST CELL DATA FOR RESETS !!!
CSARL Industrial Electronic-A&I / February 2001
NEGATIVE FLS NEGATIVE FLS
moves the power curve DOWN
PLUS FLS PLUS FLS
moves the power curve
UP
1000 1200 1400 1600 1800 2000 2200 2300 2400
900
800
700
600
500
400
300
200
100
Full Load Settings Full Load Settings
CSARL Industrial Electronic-A&I / February 2001
FULL TORQUE SETTING FULL TORQUE SETTING
1000 1200 1400 1600 1800 2000 2200 2300 2400
900
800
700
600
500
400
300
200
100
PLUS FTS PLUS FTS
raises the lower end &
lowers the top end
NEGATIVE FTS NEGATIVE FTS
raises top end &
lowers the bottom end
CSARL Industrial Electronic-A&I / February 2001
75 - 130
37 - 75
Tier I
19 -37
130 - 560
Tier II
450 - 560
75 - 225
19 - 75
>560**
8 - 19
225 - 450
96
96
97
97
98
98
99
99
00
00
01
01
02
02
03
03
04
04
05
05
06
06
07
07
08
08
US EPA Non - Road
Includes Mobile Applications of:
Industrial, PET, Machine, EPG
Excludes Marine, Loco
European Non - Road
Includes Mobile Applications of:
Industrial, PET, Machine
Excludes EPG, Marine, Loco, Ag, Forest Tractors
37 - 560
>560 BKW
8-19
Tier I
Stage I
Tier I
130 - 560
75 - 130
37 - 75
19 - 37
Stage II
37 - 75
223.7-559.3*
75 - 130
Tier III*
BKW Units
* 10/22/98 EPA - Revised
** Revision to 1/2005 Likely
130-223.7
CSARL Industrial Electronic-A&I / February 2001
Emission Sticker
Is required > especially for US re-import
Must be visible
Normally installed on front- or valve cover
CSARL Industrial Electronic-A&I / February 2001

You might also like