PCS0911A

AIR CONDITIONING SYSTEM


COOLING ONLY [50Hz ]

The match for tastefully designed offices and stores.

P eo pl e ar e dr aw n to b e a u tifu lly d e sig n e d stores that ex pres s the lates t. People work bes t in offices
i m bued w i t h f unc tio n a l b e a u ty.
Dai ki ns SkyAi r i s th e ch o ice to b rin g h ig h quality air c onditioning to s tores and offic es lik e this .
T ha nks t o i t s man y a d va n ta g e s su ch a s q u iet operation, eas e of us e and flex ible ins tallation, the SkyAir
enj o ys an excel l e n t re p u ta tio n th ro u g h o u t the world wherev er it is us ed.

Cooling only
HP
1

Capacity *

Btu/h
kW

The values given for


2 HP6 HP is for FHC type,
6.5 HP7 HP is for FDMG type.

kcal/h

2.5

3.5

18,000

21,000

26,000

30,000

5.3

6.2

7.6

8.8

4,560

5,290

6,550

7,570

FHC18NUV1

FHC21NUV1

FHC26NUV1

FHC30NUV1

R18NUV1

R21NUV1

R26NUV1 / Y1

R30NUV1 / Y1

CEILING MOUNTED
CASSETTE TYPE
Indoor unit
Outdoor unit

CEILING SUSPENDED TYPE


FH21NUV1

FH26NUV1

FH30NUV1

R21NUV1

R26NUV1 / Y1

R30NUV1 / Y1

FDBG18PUV1

FDBG21PUV1

FDBG26PUV1

R18NUV1

R21NUV1

R26NUV1 / Y1

Indoor unit
Outdoor unit

LOW STATIC
PRESSURE TYPE
Indoor unit
Outdoor unit

DUCT
CONNECTION

MIDDLE STATIC
PRESSURE TYPE
FDMG26PUV1

R30NUV1 / Y1

FDMG26NUV1

FDMG30NUV1

R26NUV1 / Y1

Indoor unit
Outdoor unit

FDMG30PUV1

R26NUV1 / Y1

Indoor unit
Outdoor unit

R30NUV1 / Y1

R26NUV1 / Y1

R30NUV1 / Y1

OUTDOOR UNIT
R18NUV1

R21NUV1

*1. Note : Rated cooling capacities are based on the following conditions: Return air temp., 27CDB, 19.0CWB; outdoor temp. 35CDB. Equiv. refrigeration piping, 7.5 m (horizontal)

CEILING SUSPENDED TYPE


Simple design and quiet
operation auto-swing air flow
brings comfort to each and
every corner of the room.
Installation and
maintenance are easy.

CEILING MOUNTED CASSETTE TYPE

DUCT CONNECTION TYPE


The indoor unit is install ed
The indoor unit is instal led
inside the ceiling and duc ts
inside the ceiling and d uc ts
discharge air in any direc tion.
discharge air in any direc tion.
Comfort is provided without
Comfort is provided without
even knowing that an air r
even knowing that an ai
conditioner is installed.
conditioner is installed.

Th is u n it is in st a lle d a t center
Th is u it is in st a lle in four
ce ilin g .n A ir is b lo wn d a t center
ce ilin g s t
b lo wn mfort.
d ire ct io.nA ir oisb rin g coin four
dp e ra t io n iso qb rintg co mfort.
ire ct io n s t u ie .
O
O p e ra t io n is q u ie t .

6.5

36,000

42,000

48,000

51,000

56,000

10.6

12.3

14.1

15.0

16.4

9,100

10,600

12,100

12,900

14,100

FHC36NUV1

FHC42NUV1

FHC48NUV1

R36NUV1 / Y1

R42NUY1

R48NUY1

FH36NUV1

FH42NUV1

FH48NUV1

R36NUV1 / Y1

R42NUY1

R48NUY1

FDMG36PUV1

FDMG42PUV1

FDMG48PUV1

FDMG51PUV1

FDMG56PUV1

R36NUV1 / Y1

R42NUY1

R48NUY1

R51NUY1

R56NUY1

FDMG36NUV1

FDMG42NUV1

FDMG48NUV1

FDMG51NUV1

FDMG56NUV1

R36NUV1 / Y1

R42NUY1

R48NUY1

R51NUY1

R56NUY1

R36NUV1 / Y1

R42NUY1

R48NUY1

R51NUY1

R56NUY1

CEILING MOUNTED

FHC-NU

CASSETTE TYPE

Quiet, decor-blending form and easy installation

Sound level

42/36

Cooling only

dB(A)

High

FHC18NU48NU

Low

FHC36NU
(220V)

Option
Accessory required for indoor unit

Wired LCD remote controller


BRC1C61
Note: Remote controller cable not
included. Cables must be
procured locally.

Wireless LCD remote controller


A signal receiver must be added to the indoor unit.

BRC7C613W
Signal receiver unit
(Installed type)
Wireless remote controller and signal
receiver unit are sold as a set.

Features

Fresh air intake kit

Long-life filter

PE fin

*2

High-efficiency filter

Ultra long-life filter

Auto-restart

Others

Ceiling soiling prevention

*1

Options

Filter sign

Pre charged for


up to 15 m

Drain pump mechanism

High ceiling application

Mould resistant treatment


for filter

Programme "Dry"

Control
features

Work & Servicing

Timer selector

Switchable fan speed

*1Applicable when wired remote controller is used


*2Applicable to R36NUR48NU outdoor units

Two selectable
temperature-sensors

Swing pattern selection

Cooling only

Auto swing

Model

Mould
prevention

Comfort

Feature

Unified square panels

Compact body and quiet operation

All models from the 18NU to 48NU


use the same size panel. Multiple
unit installations maintain a physical
uniformity that is aesthetically
pleasing and make it easier to plan
ceiling lighting systems and to
design interiors.

Indoor units use an


aerodynamically designed
Diffuser Turbo Fan

Draft resistance has been reduced


by incorporating, into a single unit,
an impeller and a diffuser to control
air flow inside the unit. The Diffuser
Turbo Fan is both quiet during
operation and compact.

Diffuser

(220V) dB(A)

950 mm

Indoor unit
Same for
all models

950 mm

Optimal comfort and convenience assured by 3 air discharge modes


Air direction
Desired situation

Draft prevention setting


When drafts are unwanted

Standard setting

Setting to prevent soiling of ceiling

For gentle drafts(Ceiling is soiled.)

When ceilings must be kept spotless

Auto-swing

Auto-swing between
10 and 40

Auto-swing between
10 and 65

Auto-swing between
30 and 65

5-levels
air direction
setting

Settable to 5 different
levels between
10 and 40

Settable to 5 different
levels between
10 and 65

Settable to 5 different
levels between
30 and 65

Draft prevention
(In heating mode)

At heating startup and thermo OFF*, air discharge is


automatically set to a near horizontal 10 to prevent direct
exposure to cool air drafts.

Auto air
direction control

The air direction is set automatically to the memorised position of the previous air direction.
(Initial setting is 65 for heating and 30 for cooling.)

At heating startup and thermo


OFF*, air discharge is
automatically set to 30 to prevent both direct
exposure to cool air drafts and contact with ceilings.

*When the thermostat turns off.

4-way flow
1 pattern

3-way flow
4 pattern

Wide air distribution


Air discharge opening increases flow
without increasing wind speed, hence
discharged air reaches farther than
before.
Air discharge distribution comparison
42NU

2-way flow
3 pattern

Note: For 3-way or 2-way flow installation, the sealing


member for air discharge outlet (option) must be
used to close off the unused outlet(s).

Air direction can be selected


according to installation.
Note: Operation sound
increases when
using 2-way or
3-way flow.

Two selectable temperature-sensors


Both indoor unit and wired remote
controller (option) contain temperaturesensors. Temperature sensing can be
set at the unit or, to further improve
comfort level, closer to the target area
at the wired remote control.This feature
require initial setting by the installer.

4 (m)

(m)
3.2
3

Super Cassette

(m) Conventional model


2.7
2.5 m/sec
2.0 m/sec
2
1.5 m/sec
1.0 m/sec
1

2.5 m/sec
2
2.0 m/sec
1.5 m/sec
1.0 m/sec 1
0.5 m/sec

0.5 m/sec

" " denotes piping direction. "


" denotes sealing
member for air discharge outlet (option) .

33
35
35
39
42
42
42

29
30
30
34
36
36
36

Quick and easy to install


Just 240 mm high. Installable in
tight ceiling spaces (18NU26NU)
240 mm *1

245 mm *2

*1 298 mm high with 30NU48NU


*2 303 mm high with 30NU48NU

Easy height adjustment

Note: Air direction is set to the standard position when the unit is shipped from the factory.
The position can be changed from the remote controller.

Multi-Flow System

Low

18NU
21NU
26NU
30NU
36NU
42NU
48NU

Blade

High

4 (m)

Each corner of the unit has an


Adjuster Pocket that
lets you easily adjust
the unit's suspended
height.
Note: If the wireless remote control
option is installed, a light
receptor unit is housed in
one of the adjuster pockets.

All models suspended


without lift
Installable in
any direction

Suitable for high ceilings


Criteria for ceiling height and number of
air discharge outlets
Number of air discharge outlets used

18NU26NU
4-way
flow
Standard
Ceiling High ceiling
height
High ceiling

3-way
flow

2-way
flow

30NU48NU
4-way
flow

3-way
flow

2-way
flow

2.7 m 3.0 m 3.5 m 3.2 m 3.6 m 4.2 m


3.0 m 3.3 m 3.8 m 3.6 m 4.0 m 4.2 m
3.5 m 3.5 m 4.2 m 4.2 m -

Note: Initial settings are for standard ceiling height and


4-way flow. High ceiling settings 1 and 2 are
set from the remote controller.

Provided with drain pump


mechanism
750 mm

Programme "Dry"
Dehumidification is microprocessor
controlled to prevent abrupt and
uncomfortable changes in air
temperature.

Switchable fan speed:


High/Low

Easy installation of options


The high-performance filter and
other options are easily clipped into
place. There is no need for a
screwdriver.

*Temperature-sensor on indoor unit must be used when


the air conditioner is controlled from another room.
**Wireless remote controller does not have a
temperature-sensor.

CEILING SUSPENDED TYPE

FH-NU

Upgrade to a quiet and compact system.

Sound level

46/40

Cooling only

High

FH21NU48NU

dB(A)

Low

FH36NU
(220V)

Option
Accessory required for indoor unit

Wired LCD remote controller


BRC1NU61
Note: Remote controller cable not
included. Cables must be
procured locally.

Wireless LCD remote controller


A signal receiver must be added to the indoor unit.

BRC7NU66

Signal receiver unit (Installed type)


Wireless remote controller and signal
receiver unit are sold as a set.

Features
Mould resistant treatment
for filter

Mould proofing
drain pan

Pre charged for


up to 15 m

*1

Others

PE fin

Timer selector

Options

Long-life filter

Programme "Dry"

*1Applicable to R36NUR48NU outdoor units

Control
features

Auto-restart

Switchable fan speed

Cooling only

Work &
Servicing

Auto swing

Model

Mould
prevention

Comfort

Feature

Spreads comfortable air throughout the room


Auto-swing (up&down)
brings comfort to the room.
Wide air discharge openings
produce a spreading 100
airflow

Installable
on ceilings
3.5 m high

Quiet operation
Sound operation has been reduced
on the exposed ceiling suspended
type unit.
(220V) dB(A)

Indoor unit

Switchable fan speed:


High/Middle/Low

High

Low

21NU

44
44
45
46
48
49

40
40
40
40
42
43

26NU
30NU
36NU
42NU

Programme "Dry"
Dehumidification is microprocessor
controlled to prevent abrupt and
uncomfortable changes in air
temperature.

100

Air is blown up to 50 in
the downward direction.

Installation flexibility for freedom of design


Uniform height and depth.
Compact design for smallcapacity models to meet tighter
dimensional constraints.
(mm)

Indoor unit 21NU 26NU 30NU 36NU 42NU 48NU


195
1,160

1,400

Uses quiet stream fan


and other quiet
technologies.

Turbulent flow Straightening


is produced
vane

50

Height
Width
Depth

48NU

Note : Anechoic chamber conversion value, measured


according to JIS parameters and criteria.

1,590

680

Weight of all models reduced (down 10% compared


with previous models). Transfer and installation work is
less arduous.

Reduced edge space,


flexible installation

All wiring and internal


servicing done from below
the unit
Pipes more easily rigged, too
Plastic panels are used to conceal
piping holes. Holes can be easily
punched out without requiring
special tools.

Quiet
stream fan

Easier to maintain
Long-life filter lasts about half
year * maintenance not required
* For dust concentration of 0.15 mg/m3

Non-dew flap without bristles


Absence of bristles minimises clinging
dirt and simplifies
cleaning.
Non-dew flap

Easy-clean, flat surfaces


It is easy to wipe dirt off the flat
side and lower surfaces of the unit.

For all maintenance tasks,


access is from bottom
surface

The unit fits more snugly into tight


spaces.
For 48NU indoor unit

30 mm
or more

1,590 mm

30 mm
or more

*Water used in the test-run can now be drained from the air discharge
opening rather than from the side as was formerly the case.

Improved-oil resistant
grille
Oil-resistant plastic is used for the air
discharge grille. This improves
durability in restaurants and other
similar environments.
Note: Intended for use in salons, dining rooms, and
ordinary sales floors, this specification is not
suitable for kitchens or other harsh environments.

FDMG-PU
FDMG-NU

DUCT CONNECTION

MIDDLE STATIC PRESSURE TYPE

Unit can be mounted in the


ceiling and air can be delivered
freely by duct.
Superior freedom of layout
The duct system allows the efficient location of
discharge outlets in accordance with the room
layout
Middle static pressure type, usable in a larger than
standard space
Duct connection is simpler with standard rear
intake chambers
Ordinary duct
(procured locally)

Air conditioner
295 mm

Ordinary duct
(procured locally)

305 mm or more
Air intake

Air discharge

Quiet operation
(220V) dB(A)

Indoor unit
Sound level

Cooling only

FDMG26PU56PU
FDMG26NU56NU

45/37dB(A)
High

38
36
37
37
37
37
37

FDMG36PU

Low

FDMG42PU

FDMG36PU

FDMG48PU
FDMG51PU

Accessory required for indoor unit

FDMG56PU

For FDMG-PU

Wired LCD remote controller

LOW

42
44
45
46
46
47
47

FDMG30PU

(220V)

Option

High

FDMG26PU

FDMG36PU

Switchable fan speed: High/Middle/Low (FDMG26NU56NU)


(FDMG26PU56PU is switchable fan speed: High/Low)

Signal receiver unit


(Separate type)
Wireless remote controller
and signal receiver unit
are sold as a set.

Model
For FDMG-NU

Cooling only

Digital remote
controller

KRC47-2A
7

Remote
controller

KRC47-1A

*1

*2

*1Applicable when wired remote controller is used (FDMG-PU)


*2Applicable to R36NUR51NU outdoor units

Others

PE fin

BRC4C64

Work & Servicing Control features

Comfort

Feature

Auto-restart

A signal receiver must be added to the indoor unit.

Features

Pre charged for


up to 15 m

Wireless LCD remote controller

Drain pipe connection can be done inside the


unit. Coolant and drain pipe outlets are at the
same opening.

Two selectable
temperature-sensors

Note: Remote controller cable not included.


Cables must be procured locally.

Switchable fan speed

BRC1C61

DUCT CONNECTION

FDBG-PU

LOW STATIC PRESSURE TYPE

Ideal for quiet, beautiful living


spaces
Suitable for condominiums and
apartments, houses and hotels
Compact
Small, lightweight, and easy-to-install indoor unit.

or more

Suction chamber
Air filter

[Duct connection]

To prevent increased operation sound, avoid installing the air suction grille
directly below the suction chamber.

Quiet operation
Sound level

Cooling only

FDBG18PU26PU

Indoor unit

High

Low

FDBG18PU

43/40dB(A)
High

(220V) dB(A)

41
43
43

38
40
40

FDBG21PU

Low

FDBG26PU

FDBG26PU
(220V)

Accessory required for indoor unit

Features

Model

Wireless LCD remote controller

Cooling only

A signal receiver must be added to the indoor unit.

BRC4C64

*1

PE fin

Note: Remote controller cable not included.


Cables must be procured locally.

Others

Auto-restart

Switchable fan speed

BRC1C61

Work & Servicing Control features

Comfort

Feature

Pre charged for


up to 10 m

Wired LCD remote controller

Two selectable
temperature-sensors

Option

*1Applicable when wired remote controller is used

Signal receiver unit


(Separate type)
Wireless remote controller
and signal receiver unit
are sold as a set.

Simultaneous air conditioning of two rooms and ventilation grille (ventilation opening)
(This feature also applies to duct connection middle static pressure type.)

When air conditioning two rooms simultaneously, the


air discharged into each room must be circulated back
to the air conditioner. To achieve this, a ventilation
duct should be installed for each room or one of the
indicated ventilation grilles should be installed on the
partitioning wall or under the door between the rooms.

Door-installed
ventilation grille

Partitioning wall

Wall-installed
ventilation grille

Under-door cutout

Ventilation grille

Ventilation grille

Under-door cutout

Ventilates air through


the partitioning wall.
(See right)

Note: The under-door cutout method should be used only when there is a small volume of airflow.

OUTDOOR UNIT

R18NU

R21NU

Quiet Operation
Fitted with wide inlet fan
(Applies to R26NU51NU)

Fully shaped
aerodynamic
propellers are
designed to
push air with a
large wing
Wide inlet fan
surface. This
provides both high blow volume and
quiet operation with minimal
turbulence.

R26/30NU

R36NU

Slim-design and low-profile


compact outdoor units

Pre charged for up to


15 metres (Applies to R36NU51NU)

(Applies to R26NU51NU)

If refrigerant piping length does not exceed


5m (R56NU), 10m (R18NU,R21NU, R26NU),
15m (R36NU, R42NU, R48NU, R51NU),
there is no need for on-site gas charging.

Compactly designed outdoor unit


with interior layout optimised for the
smooth airflow.

Allowed refrigerant pipe length and level difference

Smooth running,
minimal vibration,
low operating sound.

(Equivalent length 50 m)

R21NU

10 m

(Equivalent length 50 m)

10 m

(Equivalent length 50 m)

R42NU

10 m
15 m
15 m

Max. level
difference

30 m

15 m

30 m

15 m

30 m

20m

30 m

20m

30 m

20 m

30 m

20 m

30 m

(Equivalent length 50 m)
(Equivalent length 50 m)
(Equivalent length 50 m)

R48NU

15 m

(Equivalent length 50 m)

20 m

R51NU

500

15 m

30 m

(Equivalent length 50 m)

20 m

R56NU

5m

(Equivalent length 70 m)

50 m

30 m

(mm)

(Applies to R26NU36NU)

Note:

1Additional

refrigerant charging is required if the


refrigerant pipe is longer than the length.

4-direction piping offers


greater layout freedom
(Applies to R26NU56NU)

Piping can be run from the front,


bottom, right or rear surface
according to how the unit is installed.

Takes installation environment into consideration

Even less operation sound


(In case of V1: 220V, Y1: 380V) dB(A)

Outdoor unit

Sound level

R18NUV1

10 m

50

(Applies to R36NU56NU)

49
54
57
55
57
59
59

R51NUY1

R18NU

R30NU

Equipped with scroll


compressor for
quiet operation

R48NUY1

Max. length

R36NU

To suppress
turbulence and
achieve quiet
operation, the
curved ribs of
the grille are
optimised to meet the outflow of air.

R42NUY1

Pre charged
*1

R26NU

Curved Super Aero Grille


restricts the spread of exhaust
gas and fits in the same space
as conventional outdoor units.

(Applies to R26NU51NU)

R30NUV1
R30NUY1
R36NUV1
R36NUY1

R48/51NU

Installation and maintenance

Compact

Fitted with Super Aero Grille

R21NUV1

R42NU

Durability
Heat exchange fins provided with anti-corrosion treatment
To achieve increased durability by
improved resistance to salt corrosion
and atmospheric pollution, coated
PE fins (with special acryl
pretreatment) are used for the heat
exchanger of the outdoor unit.

Construction
Non-treated fin

Aluminium

PE fin

Hydrophilic film
Aluminium
Corrosion resistant
acrylic resin

Abundance of functions that provide comfortable


air-conditioning in stores and offices.
See the list of main functions given on the page introducing each indoor unit.

Work and Servicing

Comfort

Drain pump mechanism

Auto-swing
Delivers comfortable airconditioning to all areas,
near to and far from the airconditioner.

Air discharge direction angle can


be set (fixed setting)

Steeper gradient realises more


efficient condensate drainage.
High-lift is especially useful for
long lengths of drain piping.

Pre charged for up to 15 metres


Swing pattern selection

If refrigerant piping length does not exceed 15 m, there is no


need for on-site gas charging. (Applies to R36NU51NU)

(draft prevention, standard, ceiling soiling prevention)

You can freely set 3 air discharge positions by remote


controller.
(1) Air direction range in
standard position

(2) Air direction range in draft


prevention position

Ceiling soiling prevention function


Daikin's innovative air discharge mechanism keeps airflow
away from the ceiling. Ceiling cleaning is less frequently
required.

Filter sign
The filter sign warns you when it is time to clean the filter.

(3) Air direction range in ceiling


soiling prevention position

Switchable fan speed


High setting provides maximum reach while low setting
minimises drafts.

Programme "Dry"
Dehumidification is microprocessor controlled to prevent
abrupt and uncomfortable changes in air temperature. Useful
for reducing uncomfortable humidity without uncomfortable
cooling of the room.

High-ceiling application
Delivers air-conditioning comfort all the way down to the floor
in air-conditioning zones with high ceilings.

*When using a wired remote controller the sign is displayed in the LCD. When using a
wireless remote controller the filter sign lamp illuminates on the signal receiver unit.

Control features
Auto-restart
If there is a power outage while the equipment is operating,
operations will restart in the same mode as before the power
cut when electricity is restored.

Others
PE fin
To achieve increased durability by improved resistance to salt
corrosion and atmospheric pollution, coated PE fins (with
special acryl pretreatment) are used for the heat exchanger of
the outdoor unit. In high corrosive areas, regular maintenance
needs to be carried out.

Options
Note:When units are installed on high ceilings, depending on the model, various restrictions
concerning maximum height, air discharge direction, and choice of options may apply.

Timer selector
Operation starts when the preset time of the ON timer elapses
and stops when the preset time of the OFF timer elapses.

High-efficiency filter unit


Two types are available: 65% and 90% colorimetry.

Ultra long-life filter


Requires no maintenance for about 4 years* (10,000 h) in
stores and offices. * For dust concentration of 0.15 mg/m3

Long-life filter

Mould prevention
Mould resistant treatment for filter
Sanitary filter has mould resistant treatment.

Mould proofing drain pan


Mould proofing maintains hygiene by preventing growth in
highly humid conditions.

Maintenance is not required for one year (two years when a


ceiling mounted cassette type is used).

Fresh-air intake kit


You can provide air-conditioning with fresh air from outside.
Convenient for places where a ventilation fan cannot be installed.
Note: *Connecting ducts, insect nets, fire dampers, air filters, and other parts
should, as required, be procured locally.
**Outside Air fan interlocked with air conditioning unit is necessary. Optional
PCB(KRP1C63)is required for interlocking.
***It is recommended that the volume of outdoor air introduced through the kit
is limited to 10% of the maximum airflow rate of the indoor unit. Introducing
higher quantities will increase the operating noise and may also influence
temperature sending.

10

CEILING MOUNTED CASSETTE TYPE


Outdoor unit

Power supply
Cooling capacity 1a/1b

Btu/h
kW
kcal/h
kW

Power consumption 1a/1b


Colour

Indoor
unit

Outdoor
unit

Unit
Decoration panel
m3/min
Airflow rate (H/L)
cfm
Sound level (H/L) (220V) 2
dB(A)
mm
Dimensions Unit
(HXWXD)
mm
Decoration panel
kg
Unit
Machine weight
kg
Decoration panel
CWB
Operation range
Colour
Compressor Type
Motor output
kW
Refrigerant charge (R-22)

Sound level 2, 3
Dimensions (HXWXD)
Machine weight
Operation range
Liquid (Flare)
Piping
connections
Gas (Flare)
Drain
Indoor unit
Outdoor unit
Max. interunit piping length
Max. installation level difference
Heat insulation

30
26
48
36
42
FHC30NUV1
FHC26NUV1
FHC48NUV1
FHC36NUV1
FHC42NUV1
R30NUV1
R26NUV1
R36NUV1
R48NUY1
R42NUY1
R18NUV1
R21NUV1
R30NUY1
R26NUY1
R36NUY1
V1: 1 Phase, 220240 V, 50 Hz Y1: 3 Phase, 380415 V, 50 Hz
18,100/18,000 21,200/21,000 26,300/26,000 30,400/30,000 36,500/36,000 42,700/42,000 49,100/48,000
5.3/5.3
6.2/6.2
7.7/7.6
8.9/8.8
10.7/10.6
12.5/12.3
14.4/14.1
4,580/4,560
5,340/5,290
6,630/6,550
7,670/7,570
9,200/9,100
10,800/10,600 12,400/12,100
2.03/2.02
2.46/2.45
3.07/3.07
3.45/3.45
4.04/4.04
4.79/4.79
5.49/5.49
---------White
15/11
19/14
19/14
28/21
33/24
33/24
33/24
529/388
670/494
670/494
988/741
1,164/847
1,164/847
1,164/847
33/29
35/30
35/30
39/34
42/36
42/36
42/36
230X840X840 230X840X840 230X840X840 288X840X840 288X840X840 288X840X840 288X840X840
40X950X950
40X950X950
40X950X950
40X950X950
40X950X950
40X950X950
40X950X950
28
28
24
24
24
28
28
5
5
5
5
5
5
5
14 to 28
Ivory white
Ivory
Hermetically sealed scroll type
Hermetically sealed rotary type
4.50
1.7
2.2
2.5
3.00
2.5
3.75
2.6
1.20
1.50
2.3
2.0
2.3
2.4
(Charged for 10 m) (Charged for 10 m) (Charged for 10 m) (Charged for 10 m) (Charged for 15 m) (Charged for 15 m) (Charged for 15 m)
18
FHC18NUV1

Indoor unit

Model
Name

kg

21
FHC21NUV1

59
57
57
49
54
55
57
dB(A)
mm
540X750X270 685X800X300 770X900X320 770X900X320 1,170X900X320 1,170X900X320 1,345X900X320
92
kg
42
61
70 (V1), 69 (Y1) 70 (V1), 69 (Y1) 81 (V1), 79 (Y1)
87
CDB
21 to 46
o 9.5
mm
o 6.4
o 6.4
o 9.5
o 9.5
o 9.5
o 9.5
/
/
/
/
/
/
/
o 19.1
mm
o 15.9
o 15.9
o 15.9
o 15.9
o 19.1
o 19.1
/
/
/
/
/
/
/
mm I.Do 25XO.Do 32 I.Do 25XO.Do 32 I.Do 25XO.Do 32 I.Do 25XO.Do 32 I.Do 25XO.Do 32 I.Do 25XO.Do 32 I.Do 25XO.Do 32
/
/
/
/
/
/
/
/
/
/
/
/
/
/
mm
o 26.0 (Hole)
o 18.0 (Hole)
o 18.0 (Hole)
o 26.0 (Hole)
o 26.0 (Hole)
o 26.0 (Hole)
o 26.0 (Hole)
/
/
/
/
/
/
/
30 (equivalent length 50 m)
m
20
m
15
Both liquid and gas piping

Note :
1
Rated cooling capacities are based on the following conditions:
1a
Indoor temp., 27CDB, 19.5CWB; outdoor temp. 35CDB. Equiv. refrigeration piping, 7.5 m (horizontal).
1b
Indoor temp., 27CDB, 19.0CWB; outdoor temp. 35CDB. Equiv. refrigeration piping, 7.5 m (horizontal).
2
Anechoic chamber conversion value, measured according to JIS parameters and criteria.
During operation these values are somewhat higher owing to ambient conditions.
3
In case of V1: 220V, Y1: 380V.

CEILING SUSPENDED TYPE


Outdoor unit

Power supply
Cooling capacity 1a/1b

Power consumption 1a/1b


Colour
Airflow rate (H/L)

Indoor
unit

Outdoor
unit

Sound level (H/L) (220V) 2


Dimensions (HXWXD)
Machine weight
Operation range
Colour
Compressor Type
Motor output
Refrigerant charge (R-22)

Sound level
Dimensions (HXWXD)
Machine weight
Operation range
Piping
Liquid (Flare)
connections
Gas (Flare)
Drain
Indoor unit
Outdoor unit
Max. interunit piping length
Max. installation level difference
Heat insulation
2, 3

48
36
42
26
30
FH48NUV1
FH36NUV1
FH42NUV1
FH26NUV1
FH30NUV1
R36NUV1
R26NUV1
R30NUV1
R21NUV1
R42NUY1
R48NUY1
R36NUY1
R26NUY1
R30NUY1
V1: 1 Phase, 220240 V, 50 Hz Y1: 3 Phase, 380415 V, 50 Hz
36,500/36,000
30,400/30,000
42,700/42,000
49,100/48,000
21,200/21,000
26,300/26,000
10.7/10.6
8.9/8.8
12.5/12.3
14.4/14.1
6.2/6.2
7.7/7.6
9,200/9,100
7,670/7,570
10,800/10,600
12,400/12,100
5,340/5,290
6,630/6,550
5.50/5.50
2.72/2.71
3.48/3.48
4.06/4.06
4.83/4.83
3.10/3.10
White
42-44/24-26
22-23/9-20
26-27/22-23
32-34/22-24
38-40/23-25
22-23/9-20
776-811/317-706 776-811/317-706 917-953/776-811 1,129-1,200/776-847 1,341-1,412/811-882 1,482-1,553/847-917
49/43
46/40
45/40
48/42
44/40
44/40
195X1,590X680
195X1,400X680
195X1,590X680
195X1,590X680
195X1,160X680
195X1,160X680
35
26
26
32
35
35
14 to 28
Ivory white
Ivory
Hermetically sealed scroll type
Hermetically sealed rotary type
4.50
2.2
2.5
2.5
3.00
3.75
2.6
1.50
2.3
2.3
2.0
2.4
(Charged for 10 m) (Charged for 10 m) (Charged for 10 m) (Charged for 15 m) (Charged for 15 m) (Charged for 15 m)
21
FH21NUV1

Indoor unit

Model
Name

Btu/h
kW
kcal/h
kW
m3/min
cfm
dB(A)
mm
kg
CWB

kW
kg
dB(A)
mm
kg
CDB
mm
mm
mm
mm
m
m

54
685X800X300
61

57
770X900X320
70 (V1), 69 (Y1)

o 6.4
/
o 15.9
/
I.D o 20XO.D o 26
/
/
o 18.0 (Hole)
/

o 9.5
/
o 15.9
/
I.Do 20XO.D o 26
/
/
o 26.0 (Hole)
/

15

Note :
1
Rated cooling capacities are based on the following conditions:
1a
Indoor temp., 27CDB, 19.5CWB; outdoor temp. 35CDB. Equiv. refrigeration piping, 7.5 m (horizontal).
1b
Indoor temp., 27CDB, 19.0CWB; outdoor temp. 35CDB. Equiv. refrigeration piping, 7.5 m (horizontal).
2
Anechoic chamber conversion value, measured according to JIS parameters and criteria.
During operation these values are somewhat higher owing to ambient conditions.
3
In case of V1: 220V, Y1: 380V.

11

57
55
770X900X320
1,170X900X320
70 (V1), 69 (Y1)
81 (V1), 79 (Y1)
21 to 46
o 9.5
o 9.5
/
/
o 15.9
o 19.1
/
/
I.D o 20XO.Do 26 I.Do 20XO.D o 26
/
/
/
/
o 26.0 (Hole)
o 26.0 (Hole)
/
/
30 (equivalent length 50 m)
20
Both liquid and gas piping

57
1,170X900X320
87

59
1,345X900X320
92

o 9.5
/
o 19.1
/
I.D o 20XO.D o 26
/
/
o 26.0 (Hole)
/

o 9.5
/
o 19.1
/
I.Do 20XO.D o 26
/
/
o 26.0 (Hole)
/

DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE


Indoor unit

Model
Name

Outdoor unit

Power supply
Cooling capacity 1a/1b

Power consumption 1a/1b


Colour
Fan Airflow rate (H)

Indoor
unit

Rated external static pressure


Sound level (H/L) (220V) 2
Dimensions (HXWXD)
Machine weight
Operation range
Colour
Outdoor
Compressor Type
unit
Motor output
Refrigerant charge (R-22)
Sound level 2, 3
Dimensions (HXWXD)
Machine weight
Operation range
Piping
Liquid (Flare)
connections
Gas (Flare)
Drain
Indoor unit
Outdoor unit
Max. interunit piping length
Max. installation level difference
Heat insulation

Btu/h
kW
kcal/h
kW
m3/min
cfm
mmH2O
dB(A)
mm
kg
CWB

kW
kg
dB(A)
mm
kg
CDB
mm
mm
mm
mm
m
m

26
48
51
30
36
42
FDMG26PUV1 FDMG30PUV1 FDMG36PUV1 FDMG42PUV1 FDMG48PUV1 FDMG51PUV1
FDMG26NUV1 FDMG30NUV1 FDMG36NUV1 FDMG42NUV1 FDMG48NUV1 FDMG51NUV1
R30NUV1
R36NUV1
R26NUV1
R48NUY1
R51NUY1
R42NUY1
R30NUY1
R36NUY1
R26NUY1
V1: 1 Phase, 220240 V, 50 Hz Y1: 3 Phase, 380415 V, 50 Hz
26,300/26,000 30,400/30,000 36,500/36,000 42,700/42,000 49,100/48,000 52,200/51,000
8.9/8.8
12.5/12.3
7.7/7.6
15.3/15.0
14.4/14.1
10.7/10.6
7,670/7,570
10,800/10,600 12,400/12,100 13,200/12,900
6,630/6,550
9,200/9,100
3.15/3.15
3.46/3.46
4.16/4.16
4.84/4.84
5.55/5.55
5.90/5.90
---------42
42
23
34
37
42
1,482
1,482
811
1,200
1,306
1,482
8.5
10.1
9.8
8.0
8.0
9.8
46/37
47/37
42/38
44/36
45/37
46/37
305X1,350X680 305X1,550X680 305X1,550X680 305X1,550X680 305X1,550X680 305X1,900X680
43
51
52
52
52
58
14 to 28
Ivory
Hermetically sealed rotary type
Hermetically sealed scroll type
2.5
4.50
4.50
2.5
3.00
3.75
2.3(Charged for 10 m) 2.3(Charged for 10 m) 2.0(Charged for 15 m) 2.4(Charged for 15 m) 2.6(Charged for 15 m) 2.7 (Charged for 15 m)
57
57
59
59
55
57
770X900X320 1,170X900X320 1,170X900X320 1,345X900X320 1,345X900X320
770X900X320
87
92
93
70 (V1), 69 (Y1) 70 (V1), 69 (Y1) 81 (V1), 79(Y1)
21 to 46
o 9.5
o 9.5
o 9.5
o 9.5
o 9.5
o 9.5
/
/
/
/
/
/
o 15.9
o 19.1
o 19.1
o 19.1
o 19.1
o 15.9
/
/
/
/
/
/
3/4B (I.D o 21.6XO.D o 27.2)
/
/
o 26.0 (Hole)
o 26.0 (Hole)
o 26.0 (Hole)
o 26.0 (Hole)
o 26.0 (Hole)
o 26.0 (Hole)
/
/
/
/
/
/
30 (equivalent length 50 m)
20
Both liquid and gas piping

56
FDMG56PUV1
FDMG56NUV1
R56NUY1
57,000/56,000
16.7/16.4
14,400/14,100
6.45/6.45
42
1,482
9.8
47/37
305X1,900X680
58

4.50
2.8 (Charged for 5 m)
56
1,345X880X370
114
o 9.5
/
o 19.1
/
o 26.0 (Hole)
/
50 (equivalent length 70 m)
30

Note :
1
Rated cooling capacities are based on the following conditions:
1a
Suction temp., 27CDB, 19.5CWB; outdoor temp. 35CDB. Equiv. refrigeration piping, 7.5 m (horizontal).
1b
Suction temp., 27CDB, 19.0CWB; outdoor temp. 35CDB. Equiv. refrigeration piping, 7.5 m (horizontal).
2
Anechoic chamber conversion value, measured according to JIS parameters and criteria.
During operation these values are somewhat higher owing to ambient conditions.
3
In case of V1: 220V, Y1: 380V.

DUCT CONNECTION LOW STATIC PRESSURE TYPE


Outdoor unit

Power supply
Cooling capacity 1a/1b

Power consumption 1a/1b


Colour
Airflow rate (H/L)

Indoor
unit

Outdoor
unit

18
FDBG18PUV1

Indoor unit

Model
Name

Rated external static pressure


Sound level (H/L) (220V) 2
Dimensions (HXWXD)
Machine weight
Operation range
Colour
Compressor Type
Motor output
Refrigerant charge (R-22)

Sound level 2, 3
Dimensions (HXWXD)
Machine weight
Operation range
Liquid (Flare)
Piping
connections
Gas (Flare)
Drain
Indoor unit
Outdoor unit
Max. interunit piping length
Max. installation level difference
Heat insulation

Btu/h
kW
kcal/h
kW
m3/min
cfm
mmH2O
dB(A)
mm
kg
CWB

kW
kg
dB(A)
mm
kg
CDB
mm
mm
mm
mm
m
m

21
FDBG21PUV1

26
FDBG26PUV1
R26NUV1
R18NUV1
R21NUV1
R26NUY1
V1: 1 Phase, 220240 V, 50 Hz Y1: 3 Phase, 380415 V, 50 Hz
18,100/18,000
21,200/21,000
26,300/26,000
5.3/5.3
6.2/6.2
7.7/7.6
4,580/4,560
5,340/5,290
6,630/6,550
2.12/2.11
2.73/2.72
3.33/3.33
---------13/11
18/15
18/15
458/388
635/529
635/529
2.0
2.0
2.0
41/38
43/40
43/40
260X900X580
260X1,300X580
260X1,300X580
25
32
32
14 to 28
Ivory white
Ivory
Hermetically sealed rotary type
1.7
2.5
2.2
1.13
2.3
1.55
(Charged for 10 m)
(Charged for 10 m)
(Charged for 10 m)
49
540X750X270
42

54
685X800X300
61
21 to 46
o 6.4
/
o 15.9
/
3/4B (I.D o 21.6XO.D o 27.2)
/
/
o 18.0 (Hole)
/
30 (equivalent length 50 m)

o 6.4
/
o 15.9
/
o 18.0 (Hole)
/
15

57
770X900X320
70 (V1), 69 (Y1)
o 9.5
/
o 15.9
/
o 26.0 (Hole)
/
20

Both liquid and gas piping

Note :
1
Rated cooling capacities are based on the following conditions:
1a
Suction temp., 27CDB, 19.5CWB; outdoor temp. 35CDB. Equiv. refrigeration piping, 7.5 m (horizontal).
1b
Suction temp., 27CDB, 19.0CWB; outdoor temp. 35CDB. Equiv. refrigeration piping, 7.5 m (horizontal).
2
Anechoic chamber conversion value, measured according to JIS parameters and criteria.
During operation these values are somewhat higher owing to ambient conditions.
3
In case of V1: 220V, Y1: 380V.

12

Indoor unit
CEILING MOUNTED CASSETTE TYPE
Type
Item
Decoration panel
Sealing member for air discharge outlet
Panel spacer
Fresh air intake kit Chamber Without the T-joint pipe and fan
type
With the T-joint pipe,without fan
Direct installation type
High-efficiency filter
(Colorimetric method 65%)
(Colorimetric method 90%)
Replacement
(Colorimetric method 65%)
high-efficiency filter
(Colorimetric method 90%)
High-efficiency filter chamber
Replacement long-life filter
Ultra long-life filter
Replacement ultra long-life filter
Branch duct chamber
Remote controller
Wired type2
Wireless type
Central remote controller3
Unified ON/OFF controller3
Schedule timer3
Adaptor for wiring4
Wiring adaptor for electrical appendices3
Interface adaptor for SkyAir series
Installation box for adaptor PCB

FHC18NU

FHC21NU

FHC26NU

FHC30NU

FHC36NU

FHC42NU

FHC48NU

BYC125K-W1, BYC125K-W2
KDBH55D160W
KDBP55H160WA
KDD55DA160
KDD55DA160K
KDDJ55X160
KAF556DA160
KAF557DA160
KAFP552B160
KAFP553B160

KAF556DA80
KAF557DA80
KAFP552B80
KAFP553B80
KDDF55D160
KAF551K160
KAFP55D160
KAF55K160H

KDJ55K160

KDJ55K80
BRC1C61
BRC7C613W
DCS302CA61
DCS301BA61
DST301BA61
KRP1BA57
KRP4AA53
DTA102A52
KRP1B98

Note:
1
Required for installing high-efficiency filter or ultra long-life filter.
2
Wiring for wired remote controller to be procured locally.
3
This optional accessory requires DTA102A52.
4
Installation box for adaptor PCB (KRP1B98) is necessary.

CEILING SUSPENDED TYPE


Item
Replacement long-life filter Resin net
L-type piping kit (for upward direction)
Wired type1
Remote controller
Wireless type

Type

FH21NU

FH26NU

FH30NU

FH36NU

KAF501DA112

KAF501DA80
KHFJ5F80

FH42NU

FH48NU

KAF501DA160
KHFJ5F160

BRC1NU61
BRC7NU66

Note:
1
Wiring for wired remote controller to be procured locally.

DUCT CONNECTION
Item
Remote controller

MIDDLE STATIC PRESSURE TYPE


Type

FDMG26PU

FDMG30PU

FDMG36PU

Wired type1
Wireless type

FDMG42PU

FDMG48PU

FDMG51PU

FDMG56PU

FDMG48NU

FDMG51NU

FDMG56NU

BRC1C61
BRC4C64

Note:
1
Wiring for wired remote controller to be procured locally.

Type

Item

FDMG26NU

FDMG30NU

FDMG36NU

KRC47-1A
KRC47-2A

Remote controller
Digital remote controller

DUCT CONNECTION
Item
Remote controller

FDMG42NU

LOW STATIC PRESSURE TYPE


Type

FDBG18PU

FDBG21PU

Wired type1
Wireless type

FDBG26PU

BRC1C61
BRC4C64

Note:
1
Wiring for wired remote controller to be procured locally.

Outdoor unit
Item
Drain piping kit
Central drain plug

13

Type

R18NU

R21NU

-------

KIS95
-------

R26NU

R30NU

R36NU

R42NU

------KKPJ5F180

R48NU

R51NU

R56NU

DIMENSIONS (Unit: mm)


CEILING MOUNTED CASSETTE TYPE
FHC18NUV1 / 21NUV1 / 26NUV1 / 30NUV1 / 36NUV1 / 42NUV1 / 48NUV1

950

6
7
3

55

55

8 5

260
270
315

12-M4 Hole
(prepared hole)

150
40
350

Branch duct
connection

80

For fresh air intake kit


connection
(direct installation type)

B view

Required space

1500mm or more
1500mm
or more

1500mm
or more

1000 or more
Required space 165

125
150
B

40 A
30 10

240

Suspension
bolt
4-M8 M10

55

60

4-M4 Hole
(prepared hole)
75

[FHC18NUV1-26NUV1]
55
840
80 2 100=200 85

Branch duct
connection

C view

95
110

295

840

420

200

750
Adjustable(0~550)

A view

40
350

80

10

160

80 2 100=200 85
C

300 or less

D
E

950

780 Suspension position


860~890 Ceiling opening

Note3.

C
860~890 Ceiling opening
680 Suspension position
420

1500mm or more
When the discharge grill is closeout,the required space is
200mm or more.

----

----

FHC18NUV1-26NUV1
FHC30NUV1-48NUV1

[FHC30NUV1-48NUV1]
55
840
80 2 100=200 85

40
350

Branch duct
connection

1 Liquid pipe connection


2 Gas pipe connection

195

3 Drain pipe connection


4 Power supply connection
5 Remote control code and control wiring connection
6 Air discharge grille

1000 or more
Required space

150

Notes:
1
Location of unit's Name Plate
For Main body: Switch Box Cover inside surface of suction grille.
For decoration panel: Panel frame inside surface of suction grille.
2
When installing an optional accessory, refer to the
installation drawings.
For fresh air intake kit
Inspection port is necessary.
For high efficiency filter unit
Inspection port is not necessary.
3
In case of using wireless remote controller, this position will
be a signal receiver. Refer to the drawing of wireless remote
controller in detail.

288 298 195 165 195

14-M4 Hole
(prepared hole)
40
50
155
165

55

230 240 165

7 Air suction grille


8 Port for water supply
9 Corner decoration cover
10 Drain hose

CEILING SUSPENDED TYPE


FH21NUV1 / 26NUV1 / 30NUV1 / 36NUV1 / 42NUV1 / 48NUV1

10

Hanging bolt
4-M8~M10

115 60

15

1
5 11

195
55

300 or more
(Required space)

13

Position slit hole for taking out in piping back


(View from the front)

127

A
(Hanging position)
680

65

60

30 or more
(Service space)

30 or more
(Service space)

The Front

Obstacle
Floor side

Brand name plate


(Note.2)

Drain pipe connection VP20


(For left piping)

225
275

300
275

80

Notes:
1
Location of unit's Name Plate: Bottom of fan housing inside the suction grille.
2
In case of using wireless remote controller, this position will be a signal receiver.
Refer to the drawing of wireless remote controller in detail.
3
The remote control code is the standard <about 3 m outside the machine> attached.
(0.5 mm2 2 wicks O.D. 5.4)
(It is attached to VRV.)

80
105
170

65

1550 1590

50

80

105

Position : Hole of wall for taking out in piping back


(View from the front)
90
155

FH48NUV1

210

1550 1590

260

FH42NUV1

(Hanging
position)

1550 1590

For height installaion


From the floor side 2500 or more 155 5
(Required space)

1360 1400

FH36NUV1

145 60

40

1120 1160

FH30NUV1

85
102
160
185
192 36

FH26NUV1

12

5
135 (Required space)

170
105
90
18 17 16 142 58

1120 1160

40 135

A
FH21NUV1

4 o 45
/

55

14

1 Air discharge grille


2 Air suction grille
3 Air filter
4 Gas pipe connection
5 Liquid pipe connection
6 Drain pipe conneciton
7 Earth terminal (inside the electric components box) (M4)
8 Suspension bracket
9 Backward piping and wiring connection opening lid
10 Upward piping and wiring connection opening lid
11 Right side pipe connection
12 Left back drain pipe connection
13 Left side drain pipe connection
14 Right side drain pipe connection
15 Hole of wall for taking out in piping back
16 Upward drain pipe connection
17 Upward gas pipe connection
18 Upward liquid pipe connection

14

DIMENSIONS (Unit: mm)


DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE
FDMG26PUV1

151

600
(Suspension bolt pinch)

151
8
16
2

4
5

727

18-M4 Holes
(All around)

29

51

150
263
280

305
206
175
123

152
212
274

50

7XP150=1050

305

1134
1114

1350
1153
1137
1121
7XP150=1050

20-M4 Holes

74
16
10

126

1203
(Suspension bolt pinch)

Service space

55

427

680

300 or more

116
146
381

1350
1153

(All around)

1
2
3
4
5
6
7
8

Note: 1Location of unit's Name Plate: Chamber cap

Liquid pipe connection


Gas pipe connection
Drain pipe connection
Ground terminal
Switch box
Control wiring intake (for remote controller)
Control wiring intake (for outdoor unit)
Suspension bracket

FDMG30PUV1 / 36PUV1 / 42PUV1 / 48PUV1 / 51PUV1 / 56PUV1


A
151

381

126
151
8
16

305
206
175
123

827

(All Around)
Liquid pipe connection
Gas pipe connection
Drain pipe connection
Ground terminal

5
6
7
8

29

N
(All Around)

Switch box
Control wiring intake (for remote controller)
Control wiring intake (for outdoor unit)
Suspension bracket
Note: 1Location of unit's Name Plate: Chamber cap

A
B
C
E
F
D
FDMG30NUV1/36NUV1/42NUV1/48NUV1 1550 1353 1403 1334 1314 7XP150=1050
FDMG51NUV1/56NUV1
1900 1703 1753 1684 1664 9XP150=1350

15

51

G
18-M4
Holes

22-M4
Holes

H
J
K
M
L
1550 1353 1337 1321 7XP150=1050
1900 1703 1687 1671 9XP150=1350

20-M4

263

24-M4

269

Holes
Holes

10

J
K
L
M

150
O
280

2
152
212
274

50

D
E
F

74
16

C
(Suspension bolt pinch)

305

1
2
3
4

Service space

55

427

680

300 or more

146

600
(Suspension bolt pinch)

116

DUCT CONNECTION MIDDLE STATIC PRESSURE TYPE


FDMG26NUV1

151

300 or more

600
(Suspension bolt pinch)

Service space

55

427

680

116
146
381

1350
1153

126

1134
1114

1350
1153
1137
1121
7XP150=1050

51

5
305

305
206
175
123

152
212
274

50

7XP150=1050

151
8
16

150
263
280

1203
(Suspension bolt pinch)

727

18-M4 Holes

29

(All around)

7
20-M4 Holes

74
16
10

(All around)

1
2
3
4
5
6
7
8

Note: 1Location of unit's Name Plate: Chamber cap

Liquid pipe connection


Gas pipe connection
Drain pipe connection
Ground terminal
Switch box
Control wiring intake (for remote controller)
Control wiring intake (for outdoor unit)
Suspension bracket

FDMG30NUV1 / 36NUV1 / 42NUV1 / 48NUV1 / 51NUV1 / 56NUV1


A
151

381

146

116

Service space

55

427

680

600

(Suspension bolt pinch)

300 or more

126

(Suspension bolt pinch)


H
151

150

263

280

74

10

305

274

16

29

212

50

152
827

L
M

51

123

175

206

16

305

(All Around)

N
(All Around)

1
2
3
4

Liquid pipe connection


Gas pipe connection
Drain pipe connection
Ground terminal

5
6
7
8

Switch box
Control wiring intake (for remote controller)
Control wiring intake (for outdoor unit)
Suspension bracket
Note: 1Location of unit's Name Plate: Chamber cap

A
B
C
E
F
D
FDMG30NUV1/36NUV1/42NUV1/48NUV1 1550 1353 1403 1334 1314 7XP150=1050
FDMG51NUV1/56NUV1
1900 1703 1753 1684 1664 9XP150=1350

G
18-M4
Holes

22-M4
Holes

H
J
K
M
L
1550 1353 1337 1321 7XP150=1050
1900 1703 1687 1671 9XP150=1350

N
20-M4
Holes

24-M4
Holes

16

DIMENSIONS (Unit: mm)


DUCT CONNECTION LOW STATIC PRESSURE TYPE
FDBG18PUV1 / 21PUV1 / 26PUV1
B

151

Unit(mm)

126

10 or more

5
6
7
8

260

110
170
228

Liquid pipe connection


Gas pipe connection
Drain pipe connection
Ground terminal

29

7
O
(All around)

16
10
151

I
J
K
L
M

Switch box
Control wiring intake (for remote controller)
Control wiring intake (for outdoor unit)
Suspension bracket
Note: 1Location of unit's Name Plate: Chamber cap

FDBG18PUV1
FDBG21PUV1/26PUV1

17

150
219
236

N
(All around)
1
2
3
4

Service space

A
B
C
F
D
E
900 704 755 684 664 3XP150=450
1300 1104 1155 1084 1064 6XP150=900

G
500
700

H
127
102

52
16
10

C
(Suspension bolt pinch)
D
E
F

260
164
134
107

50

300 or more

55

317

580

500
(Suspension bolt pinch)
137
167
271

3XP150=450 674 688 704 900


6XP150=900 1074 1088 1104 1300

10-M4 12-M4
Holes

Holes

16-M4 18-M4
Holes

Holes

OUTDOOR UNIT
R18NUV1
700

Holes for anchor bolts


(M8 or M10)

520

190
170

60
27

95

237
213
48

290
306

3-Drain outlets

34
72

100

530

15

540

750

270

Terminal cover
Earth
terminal
(M4)
Power intake
Gas stop valve

Name
plate

105

34

Liquid stop valve

58

27

Service port

Minimum space for air passage

H
Less than 1000
More than 1000

Space A
More than 300
More than 600

100

50

150

50
50

R21NUV1
Holes for anchor bolts
(M8 or M10)

330
350

98

31

269

540

130

2-Drain outlet

800

Outdoor
air thermostat

300

15
Earth terminal
(M4)
Power intake

Name plate

685
645

Liquid
stop valve

Liquid pipe

95 70

Service port
Gas
stop valve

75

100

Gas pipe
A

50

50

100

50

150

Minimum space for air passage

H
H 1000
H 1000

A
300
600

18

DIMENSIONS (Unit: mm)


OUTDOOR UNIT

Hole for anchor


bolt 4-M12

48
55

320

350
(345~355)

30

R26NUV1/Y1
R30NUV1/Y1

140
30

30

40

96
140

620
900

3
2
1
6

6
5
4

89

19

71

28

89
142

223
53 95

54 95
84 55

54 95
143

60

329
352

55

770

5
4

16

80
145

52
13

67

70 102 117

58

16

19

4
45

376

1 Gas pipe connection


2 Liquid pipe connection

191

3 Grounding terminal M5(in switch box)


4 Refrigerant piping intake
5 Power supply wiring intake
6 Control wiring intake
7 Drain connection

Note: In some circumstances, with certain machine types,


it may not be possible to attach the supplied piping.

Hole for anchor


bolt 4-M12

140
30

41

320
30

96
140

620
900

61

48

350
(345~355)

30

R36NUV1/Y1

4
2
1
3
7

1170

191

148

223

95
54

54
58

70 102 117

19

376

52
13

67

16

5
45

80
145

19

19

16

71

84 55

410
435
95

157.5

60
89
24

89
142

54

1
2
3
4
5
6
7
8

Gas pipe connection


Liquid pipe connection
Service port(in the unit)
Grounding terminal
Refrigerant piping intake
Power supply wiring intake
Control wiring intake
Drain pipe connection

OUTDOOR UNIT
R42NUY1, R48NUY1, R51NUY1

1170

54

113

579

R48NUY1/51NUY1

1345

55

48
61
320

350
(345~355)

30

R42NUY1

Hole for anchor


bolt 4-M12

140

30

41

96
140

620
900

30

4
2
1
3
7
7

19

142

95
53

84

95
54

89 19
D

55

410
435
95
54

60
89

24

223

80
145

13

3 Service port (in the unit)


4 Grounding terminal M5 (in switch box)
5 Refrigerant piping intake

58

70 102 117

376

6 Power supply wiring intake


7 Control wiring intake

191

8 Drain pipe connection

30

Hole for anchor


bolt 4-M12

146

584

30

35

370

84
38

396

150

880

30

4
3
2
1
7
1345

6
5

144

84
14 67
115

14

90

1 Gas pipe connection


2 Liquid pipe connection

5
391

5
60

49

61 11

90 14
137
102 11

5
95

568

49

84

name plate

40

24

95

60

538

7
6

275

R56NUY1

1 Gas pipe connection


2 Liquid pipe connection

5
45

67

16
16

71

52

3 Service port(in the unit)


4 Grounding terminal M5(in switch box)
5 Refrigerant piping intake
6 Power supply wiring intake
7 Control wiring intake
8 Drain outlet

20

DIMENSIONS

(Unit: mm)

REMOTE CONTROLLER

Wireless type

Remote controller dimensions

BRC7C613W BRC4C64

CEILING MOUNTED CASSETTE TYPE

Remote controller holder


installation procedure
<Installation to wall surface>

157

Transmitting part

Receiver installation procedure


Receiver

Drain piping
side

Liquid crystal
remote controller
(Wireless)
Remote controller
holder

62

Receiver detail

Refrigerant
piping side
Decoration panel

17.5

BRC7NU66

CEILING SUSPENDED TYPE

Transmitting part

Remote controller holder


installation procedure
<Installation to wall surface>

Receiver installation procedure

The Front

Receiver detail

Receiver

115.5

Remote controller
(Wireless)
Remote controller
holder

54

18.1

Receiver detail
2-5x9 Slot

18 0.535

70

49

Switch box

(Ceiling opening)

(field Supplied parts)

Wired type

Remote controller dimensions

KRC47-2A
25

18

19

58

38
17

18
23 28
46

Conduit

17

CONTROL BOX

Note) 1. Remote controller cord and


staple are not attached. they are
field supplied parts.

(12~16)

Specifications of cord
Vinyl cord with sheath or cable
Type
(Insulated thickness: 1 mm or more)
Size
0.75~1.25 mm2
Total length
500 m

* Countries requiring EMC: Shield wire


(insulated thickness: 1 mm or more)
44.5
6

20 25

119

24

B
B

17 R2

10

22 25
13

25 20

41

38
41.5

A
A

Note)
The dimension of hole.
a
4

BRC1NU61

111

Through hole

17

( Distance between
remote controller
and control box )

Hole type a (mm)


A
6
B
10

KRC47-1A
136
124
81

0~5
17

C Exposed body,
embedded code

77

Staple

B Exposed body,
embedded cord

14

117

A EXposed body,
exposed cord

92
61

Remote controller installation procedure

Cord
outlet
hole

36

120

21

110

84

120

42

BRC1C61

85

32

More than 90
(Srevice space)

120

72
83.5
106

(Ceiling opening)

Service space for ceiling


installation

Note : install more than 3


Do not
receivers in the vicinity of one
another.
With 4 or more units, there is
always the possibility of
malfunction

[Space required for outdoor unit installation] (Unit: mm)


Dimensions inside brackets [ ] indicate case where air direction adjustment guide is adjusted downward.

The values represent the case for the R26 type through R56 type.
The dimensions in ( ) are for the R36 and R56 type (The unit values is mm. )
In case of R56 model, the values in < > are those when the air discharge direction of the grille is downward.

For R26NU-56NU

When there is an obstruction


on the inlet side

When there is an obstruction


on the outlet side

When the overhead space is open

When the overhead space is open

1. For single unit installation

1. For single unit


installation

When there is an
obstruction only
on the inlet side

2. For series installation


(more than two units)
0)

0
0(1

or

ore

500

or m

re

mo

When there are


obstructions on
both sides

ore

rm

0o

or m

ore

100

or m

0
10

ore

When there is an obstruction


in the overhead space

re

mo

or

ss

500

or le

1000 or more

100

100

1. For single unit


installation
2. For series installation
(more than two units)
When there are
obstructions on
both sides

0o

ore

2. For series installation


(more than two units)

500

or m

ss

or le

500

1000 or more

100

An obstruction
in the overhead space

rm

ore
200

0)

or m

0
0(3

ore

or

An obstruction
in the overhead space

re

mo

20

ore

rm

0o

100

When there is an obstruction


in the overhead space

When there are obstructions on both


the inlet and outlet sides

1. For single unit installation


500

ss

or le

1000 or more

When there is an
obstruction on the
inlet side
An obstruction
in the overhead space

Pattern 1

When the obstruction on the outlet side is higher than


the unit itself (There is no limit to the height of the
obstruction on the outlet side.)

When the overhead space is open

ore

100

or m

1. For single unit installation

1000 or more

When there are obstructions


on the inlet side and
ss
or le
both lateral sides
500

For other patterns, please refer


to engineering databook.

An obstruction
in the overhead space
or

mo

L
re

150

or

ore

150

mo

re

or m

2. For series installation (more than two units)

ss

1000 or more

500

or le

An obstruction
in the overhead space
0o

ore
or m
500 1000>
<

)
100
50( more
or

2. For series installation


(more than two units)

When there are obstructions


on the inlet side and
both lateral
sides

100

rm

ore
200

or

re

(3
00

ore
rm
0o >
100 1500
<

0)
(30
200 more
or

ore

rm

)o

00

mo

150

22

Warning

Daikin products are manufactured for export to numerous countries throughout the world. Prior to
purchase, please confirm with your local authorised importer, distributor and/or retailer whether this
product conforms to the applicable standards, and is suitable for use, in the region where the product
will be used. This statement does not purport to exclude, restrict or modify the application of any local
legislation.
Ask a qualified installer or contractor to install this product. Do not try to install the product yourself.
Improper installation can result in water or refrigerant leakage, electrical shock, fire or explosion.
Use only those parts and accessories supplied or specified by Daikin. Ask a qualified installer or
contractor to install those parts and accessories. Use of unauthorised parts and accessories or
improper installation of parts and accessories can result in water or refrigerant leakage, electrical
shock, fire or explosion.
Read the User's Manual carefully before using this product. The User's Manual provides important
safety instructions and warnings. Be sure to follow these instructions and warnings.
If you have any enquiries, please contact your local importer, distributor and/or retailer.

Cautions on product corrosion


1. Air conditioners should not be installed in areas where corrosive gases, such as acid gas or alkaline gas, are produced.
2. If the outdoor unit is to be installed close to the sea shore, direct exposure to the sea breeze should be avoided. If you need to install
the outdoor unit close to the sea shore, contact your local distributor.
Organization:
DAIKIN INDUSTRIES, LTD.
AIR CONDITIONING MANUFACTURING DIVISION

JMI-0107

Scope of Registration:
THE DESIGN/DEVELOPMENT AND MANUFACTURE OF
COMMERCIAL AIR CONDITIONING, HEATING, COOLING,
REFRIGERATING EQUIPMENT, COMMERCIAL HEATING
EQUIPMENT, RESIDENTIAL AIR CONDITIONING
EQUIPMENT, HEAT RECLAIM VENTILATION, AIR
CLEANING EQUIPMENT, MARINE TYPE CONTAINER
REFRIGERATION UNITS, COMPRESSORS AND VALVES.

Organization:
DAIKIN INDUSTRIES
(THAILAND) LTD.

JQA-1452

Scope of Registration:
THE DESIGN/DEVELOPMENT
AND MANUFACTURE OF AIR
CONDITIONERS AND THE
COMPONENTS INCLUDING
COMPRESSORS USED FOR THEM

Dealer

All of the Daikin Groups business


facilities and subsidiaries in Japan
are certified under the ISO 14001
international standard for
environment management.

Head Office:
Umeda Center Bldg., 2-4-12, Nakazaki-Nishi,
Kita-ku, Osaka, 530-8323 Japan
Tokyo Office:
JR Shinagawa East Bldg., 2-18-1, Konan,
Minato-ku, Tokyo, 108-0075 Japan

http://www.daikin.com/global_ac/
c All rights reserved

Specifications, designs and other content appearing in this brochure are current as of April 2011 but subject to change without notice.